Sample records for computerized tomographic scan

  1. Computerized tomographic system

    International Nuclear Information System (INIS)

    Godbarsen, R.; Barrett, D.M.; Garrott, P.M.; Foley, L.E.; Redington, R.W.; Lambert, T.W.; Edelheit, L.S.

    1981-01-01

    A computerized tomographic system for examining human breasts is described in detail. Conventional X-ray scanning apparatus has difficulty in achieving the levels of image definition and examination speeds required for mass screening. A novel method of scanning successive layers of the breast with a rotating X-ray beam is discussed and details of the control circuitry and sequence steps are given. The method involves immersing the breast in an inner fluid (e.g. water) filled container which is stationary during an examination and is surrounded by a large outer container which is also filled with the fluid; the inner and outer containers are always maintained at a constant height and the X-ray absorption across the fan-shaped beam is as close as possible to constant. (U.K.)

  2. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  3. Spiral Computed Tomographic Imaging Related to Computerized Ultrasonographic Images of Carotid Plaque Morphology and Histology

    DEFF Research Database (Denmark)

    Grønholdt, Marie-Louise M.; Wagner, Aase; Wiebe, Britt M.

    2001-01-01

    Echolucency of carotid atherosclerotic plaques, as evaluated by computerized B-mode ultrasonographic images, has been associated with an increased incidence of brain infarcts on cerebral computed tomographic scans. We tested the hypotheses that characterization of carotid plaques on spiral comput...

  4. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  5. Cardiac imaging systems and methods employing computerized tomographic scanning

    International Nuclear Information System (INIS)

    Richey, J.B.; Wake, R.H.; Walters, R.G.; Hunt, W.F.; Cool, S.L.

    1980-01-01

    The invention relates to cardiac imaging systems and methods employing computerised tomographic scanning. Apparatus is described which allows an image of the radiation attenuation of the heart at a desired phase of the cardiac cycle. The patients ECG signal can be used in a transverse-and-rotate type CT scanner as a time base, so that the beam reaches the heart at a desired phase of the cardiac cycle, or, in a purely rotational-type CT scanner continuously generated scan data is only stored for corresponding phases of successive cardiac cycles. Alternatively, gating of the beams themselves by shuttering or switching the power supply can be controlled by the ECG signal. A pacemaker is used to stabilize the cardiac period. Also used is a system for recognising unacceptable variations in the cardiac period and discarding corresponding scan data. In a transverse-and-rotate type fan-beam CT scanner, the effective beam width is narrowed to reduce the duration of the traverse of the heart. (U.K.)

  6. Performance of analytical methods for tomographic gamma scanning

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.

    1997-01-01

    The use of gamma-ray computerized tomography for nondestructive assay of radioactive materials has led to the development of specialized analytical methods. Over the past few years, Los Alamos has developed and implemented a computer code, called ARC-TGS, for the analysis of data obtained by tomographic gamma scanning (TGS). ARC-TGS reduces TGS transmission and emission tomographic data, providing the user with images of the sample contents, the activity or mass of selected radionuclides, and an estimate of the uncertainty in the measured quantities. The results provided by ARC-TGS can be corrected for self-attenuation when the isotope of interest emits more than one gamma-ray. In addition, ARC-TGS provides information needed to estimate TGS quantification limits and to estimate the scan time needed to screen for small amounts of radioactivity. In this report, an overview of the analytical methods used by ARC-TGS is presented along with an assessment of the performance of these methods for TGS

  7. Computerized tomographic in non-destructive testing

    International Nuclear Information System (INIS)

    Lopes, R.T.

    1988-01-01

    The process of computerized tomography has been developed for medical imaging purposes using tomographs with X-ray, and little attention has been given to others possibles applications of technique, because of its cost. As an alternative for the problem, we constructed a Tomographic System (STAC-1), using gamma-rays, for nonmedical applications. In this work we summarize the basic theory of reconstructing images using computerized tomography and we describe the considerations leading to the development of the experimental system. The method of reconstruction image implanted in the system is the filtered backprojection or convolution, with a digital filters system to carried on a pre-filtering in the projections. The experimental system is described, with details of control and the data processing. An alternative and a complementary system, using film as a detector is shown in preliminary form . This thesis discuss and shows the theorical and practical aspects, considered in the construction of the STAC-1, and also its limitations and apllications [pt

  8. Computerized tomographic scanner with shaped radiation filter

    International Nuclear Information System (INIS)

    Carlson, R.W.; Walters, R.G.

    1981-01-01

    The invention comprises a shaped filter and a filter correction circuitry for computerized tomographic scanners. The shaped filter is a generally u-shaped block of filter material which is adapted to be mounted between the source of radiation and the scan circle. The u-shaped block has a parabolic recess. The filter material may be beryllium, aluminum, sulphur, calcium, titanium, erbium, copper, and compounds including oxides and alloys thereof. The filter correction circuit comprises a first filter correction profile adding circuit for adding a first scaler valve to each intensity valve in a data line. The data line is operated on by a beam hardness correction polynomial. After the beam hardness polynomial correction operation, a second filter correction circuit adds a second filter correction profile consisting of a table of scalor values, one corresponding to each intensity reading in the data line

  9. Computerized tomographic quantification of chronic obstructive pulmonary disease as the principal determinant of frontal P vector.

    Science.gov (United States)

    Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David

    2012-04-01

    Verticalization of the P-wave axis is characteristic of chronic obstructive pulmonary disease (COPD). We studied the correlation of P-wave axis and computerized tomographically quantified emphysema in patients with COPD/emphysema. Individual correlation of P-wave axis with different structural types of emphysema was also studied. High-resolution computerized tomographic scans of 23 patients >45 years old with known COPD were reviewed to assess the type and extent of emphysema using computerized tomographic densitometric parameters. Electrocardiograms were then independently reviewed and the P-wave axis was calculated in customary fashion. Degree of the P vector (DOPV) and radiographic percent emphysematous area (RPEA) were compared for statistical correlation. The P vector and RPEA were also directly compared to the forced expiratory volume at 1 second. RPEA and the P vector had a significant positive correlation in all patients (r = +0.77, p <0.0001) but correlation was very strong in patients with predominant lower lobe emphysema (r = +0.89, p <0.001). Forced expiratory volume at 1 second and the P vector had almost a linear inverse correlation in predominantly lower lobe emphysema (r = -0.92, p <0.001). DOPV positively correlated with radiographically quantified emphysema. DOPV and RPEA were strong predictors of qualitative lung function in patients with predominantly lower lobe emphysema. In conclusion, a combination of high DOPV and predominantly lower lobe emphysema indicates severe obstructive lung dysfunction in patients with COPD. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  11. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  12. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  13. Computerized tomographic findings in children with head trauma in ...

    African Journals Online (AJOL)

    Objective: To describe the computerized tomographic findings in children with head trauma who presented at the University of Benin Teaching Hospital, Benin City, Nigeria. Methods: It is a retrospective review of patients aged 0 – 15 years with suspected intracranial injury (ICI) following head trauma, who presented for CT ...

  14. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  15. Development of a computerized tomographic system based on the FAN-BEAM technique

    International Nuclear Information System (INIS)

    Junqueira, M.M.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory, at COPPE/UFRJ, concentrates its researches in the development of computerized tomographic systems, looking for applications in industrial and medical non destructive analysing techniques. In this work we have projected and constructed a tomographic prototype, based on the FAN-BEAM technique for irradiating the object under analysis. An algorithm previously developed to analyse parallel beams, was modified and adapted to the FAN-BEAM geometry. (Author) [pt

  16. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  17. ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Huang, S.C.; Kuhl, D.E.

    1977-01-01

    The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems

  18. Anatomical Variations of Carotid Artery and Optic Nerve in Sphenoid Sinus Using Computerized Tomographic Imaging

    Directory of Open Access Journals (Sweden)

    Nikakhlagh

    2014-12-01

    Full Text Available Background Sphenoid sinus is surrounded by many vital vascular and nervous structures. In more than 20% of patients with chronic sinusitis, involvement of sphenoid sinus has been observed. Besides, sphenoid sinus is an appropriate route to access anterior and middle cranial fossa in surgery. Therefore, it is important to have an adequate knowledge about the contents of sphenoid sinus and its proximity for nasal endoscopy, sinus surgeries and neurosurgeries. Objectives The aim of this study was to study sphenoid sinus proximity with carotid artery and the optic nerve using computerized tomographic imaging. Materials and Methods In this prospective study, computerized tomographic images of sphenoid sinus of patients referred to Imam Khomeini and Apadana hospitals were studied. The images were studied regarding any bulging, as well as not having a bone covering in sphenoid sinus regarding internal carotid artery and optic nerve. Furthermore, unilateralness or bilateralness of their relationships was studied. Results Among 468 coronal and axial CT scan images of sphenoid sinus, 365 (78% showed post-sellar pneumatization and 103 (22% pre-sellar pneumatization. Regarding existence of internal septa, 346 (74% cases showed multiple septation, and the remaining images were reported to have a single septum. According to the reports of CT scan images, the existence of bulging as a result of internal carotid artery and uncovered artery were 4.22% and 5.8% in the right sinus, 4.9% and 5.4% in the left sinus, and 4.34% and 4.6% in both sinuses, respectively. According to the reports of CT scan images, existence of bulging as a result of optic nerve and uncovered nerve were 5.7% and 4.3% in the right sinus, 6% and 5.4% in the left sinus, and 12% and 3.2% in both sinuses, respectively. Conclusions Due to variability of sphenoid sinus pneumatization and the separator blade of the two sinus cavities, careful attention is required during sinus surgery to avoid

  19. Computerized industrial tomography

    International Nuclear Information System (INIS)

    Ashraf, M.M.

    1999-01-01

    Computerized Tomographic (CT) has been used for a number of applications in the field of medicine and industry. For the last couple of years, the technique has been applied for the material characterization and detection of defects and flaws inside the industrial components of nuclear, aerospace and missile industries. A CT scanner of first generation was developed at the institute. The scanner has been used to demonstrate couple of applications of CT in the field of non destructive testing of materials. The data acquired by placing the test objects at various angles and scanning the object through a source detector assembly has been processed on a Pentium computer for image reconstruction using a filtered back projection method. The technique has been developed which can be modified and improved to study various other applications in materials science and a modern computerized tomographic facility can be established. (author)

  20. Gamma Ray Tomographic Scan Method for Large Scale Industrial Plants

    International Nuclear Information System (INIS)

    Moon, Jin Ho; Jung, Sung Hee; Kim, Jong Bum; Park, Jang Geun

    2011-01-01

    The gamma ray tomography systems have been used to investigate a chemical process for last decade. There have been many cases of gamma ray tomography for laboratory scale work but not many cases for industrial scale work. Non-tomographic equipment with gamma-ray sources is often used in process diagnosis. Gamma radiography, gamma column scanning and the radioisotope tracer technique are examples of gamma ray application in industries. In spite of many outdoor non-gamma ray tomographic equipment, the most of gamma ray tomographic systems still remained as indoor equipment. But, as the gamma tomography has developed, the demand on gamma tomography for real scale plants also increased. To develop the industrial scale system, we introduced the gamma-ray tomographic system with fixed detectors and rotating source. The general system configuration is similar to 4 th generation geometry. But the main effort has been made to actualize the instant installation of the system for real scale industrial plant. This work would be a first attempt to apply the 4th generation industrial gamma tomographic scanning by experimental method. The individual 0.5-inch NaI detector was used for gamma ray detection by configuring circular shape around industrial plant. This tomographic scan method can reduce mechanical complexity and require a much smaller space than a conventional CT. Those properties make it easy to get measurement data for a real scale plant

  1. Computerized tomography

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the design of computerized tomographic X-ray equipment are described which lead to improvements in the mechanical properties, speed and size of scanning areas. The method envisages the body being scanned as a two-dimensional matrix of elements arising from a plurality of concentric rings. The concentric centre need not coincide with the axis of rotation. The procedures for rotation of the X-ray beam and detectors around the patient and for translating the measured information into attenuation coefficients for each matrix element of the body are described in detail. Explicit derivations are given for the mathematical formulae used. (U.K.)

  2. Computerized tomographic studies in cerebral palsy

    International Nuclear Information System (INIS)

    Sugie, Yoko

    1981-01-01

    Computed tomographic (CT) findings in 200 children with cerebral palsy (CP) were analysed from the viewpoint of clinical manifestations, disease complications and etiological factors. CT scans of 135 cases (67.5%) were found to be abnormal and there were 14 (7%) borderline cases. The major abnormality found on CT scans was cerebral atrophy. Other important changes included focal or diffuse low density area in the brain tissue, congenital malformation, and cerebellar atrophy. From the clinical point of view, a large number of patients with spastic tetraplegia and spastic diplegia showed highly abnormal CT scans. On the other hand, in patients with spastic monoplegia, spastic paraplegia, and athetotic type, CT findings were normal or revealed only minor cerebral atrophy. Most children showing asymmetric clinical symptoms had corresponding asymmetric CT abnormalities which included ventricular enlargement, low density area in the brain tissue, and hemispherical volume. There was a significant correlation between the severity of physical impairment and the extent of CT abnormalities. Severely affected children had grossly abnormal CT scans such as hydranencephaly, polycystic change, and extensive cerebral atrophy. In the patients complicated with epilepsy, the incidence and severity of abnormal CT were higher than those of non-epileptic patients. Mentally retarded patients had variable enlargement of the subarachnoidal space depending on the severity of their mental retardation. Patients with suspected postnatal etiology also had high incidence of severe CT abnormality. CT scan is a valuable tool for evaluating patients with CP and in some cases, possible etiology of the disease may be discovered. (author)

  3. Ultrafast CT scanning of an oak log for internal defects

    Science.gov (United States)

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  4. Motion-Computerized Tomographic Colography is a Better Method for Screening for Polyps: Arguments for the Motion

    Directory of Open Access Journals (Sweden)

    Benoit C Pineau

    2003-01-01

    Full Text Available Colorectal cancer is an important public health problem that is amenable to prevention and early treatment. Traditional screening techniques - fecal occult blood testing, flexible sigmoidoscopy, barium enema and colonoscopy - each have limitations in terms of diagnostic accuracy, cost and/or patient acceptability. Compliance with recommendations for screening has been poor, in part, because of negative perceptions about the available modalities. Virtual colonoscopy, or computerized tomographic colography, is a minimally invasive technique that safely evaluates the entire colon and does not require sedation. Thorough cleansing as well as immobilization and air insufflation of the colon is crucial to a successful examination. Sensitivity and specificity rates are reasonable, compared with conventional colonoscopy, and it has been shown that the latter technique can be averted in over two-thirds of cases, with few false-negative examinations. Most patients find virtual colonoscopy more acceptable than the conventional technique, and would prefer it if a repeat procedure were warranted. An economic analysis that found that computerized tomographic colography was less cost effective than conventional colonoscopy did not consider the indirect costs of the latter, which is an important limitation. Virtual colonoscopy is a novel radiological technique that may revolutionize screening for colorectal cancer.

  5. First experience with a mobile computed tomograph in the USSR

    International Nuclear Information System (INIS)

    Portnoj, L.M.

    1989-01-01

    Utilization experience of mobile computerized tomograph mounted in the bus is presented. Problems concerning staff, selection of medical base institutes etc are considered. Efficiency of mobile computerized tomographes in revealing different diseases is pointed out

  6. Tomographic scanning apparatus with ionization detector means

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus using a fan beam and digital output signal. Particular reference is made to the gas-pressurized ionization detector chamber, consisting of an array of side-by-side elongate ionization detection cells, the principal axis of each of the said cells being oriented along a radius extending towards the radiation source, and connection means for applying potentials across the cells for taking their output signals. (U.K.)

  7. Line-scanning tomographic optical microscope with isotropic transfer function

    International Nuclear Information System (INIS)

    Gajdátsy, Gábor; Dudás, László; Erdélyi, Miklós; Szabó, Gábor

    2010-01-01

    An imaging method and optical system, referred to as a line-scanning tomographic optical microscope (LSTOM) using a combination of line-scanning technique and CT reconstruction principle, is proposed and studied theoretically and experimentally. In our implementation a narrow focus line is scanned over the sample and the reflected light is measured in a confocal arrangement. One such scan is equivalent to a transverse projection in tomography. Repeating the scanning procedure in several directions, a number of transverse projections are recorded from which the image can be obtained using conventional CT reconstruction algorithms. The resolution of the image is independent of the spatial dimensions and structure of the applied detector; furthermore, the transfer function of the system is isotropic. The imaging performance of the implemented confocal LSTOM was compared with a point-scanning confocal microscope, based on recorded images. These images demonstrate that the resolution of the confocal LSTOM exceeds (by 15%) the resolution limit of a point-scanning confocal microscope

  8. A computerized tomographic study in patients with delusional and non-delusional depression

    International Nuclear Information System (INIS)

    Shiraishi, Hiroyasu; Koizumi, Junzo; Hori, Masashi; Terashima, Yasushi; Suzuki, Toshihito; Saito, Kiichiro; Mizukami, Katsuyoshi; Tanaka, Yoshiro; Yamaguchi, Naomi

    1992-01-01

    This is a description of a computerized tomographic study of 45 non-delusional depressed, 29 delusional depressed patients and 77 neurotic control subjects. The cerebral atrophy ratio (CAR) on the three different slices and the ventricular ratio (VBR) of the anterior horn and the body of the lateral ventricles were calculated, analyzed and compared using Student's t test. Compared to the control subjects, the non-delusional depressive patients had greater CAR values than the controls but there were no significant differences of VBR values between the two groups. The patients with delusional depression had significantly larger CAR and VBR values than the non-delusional depressives and control subjects. The delusional depressives had greater brain atrophy than the non-delusionals and it was suggested that organic cerebral factors may have etiological significance in the depressions, especially the delusional depressives. (author)

  9. Comparative validation of the radiographic and tomographic measurement of patellar height

    Directory of Open Access Journals (Sweden)

    Marco Antonio Schueda

    2013-09-01

    Full Text Available OBJECTIVE: To evaluate and validate the radiographic measurement of patellar height with computerized tomography scans. METHODS: Measured the patellar height through the lateral radiographic image supported by one foot and sagittal tomographic view of the knee in extension, flexion of 20°, and quadriceps contraction of 40 patients (80 knees, asymptomatic and no history of knee injuries using Insall-Salvati index. There were 20 adult females and 20 adult males. RESULTS: The height patellar index was higher in women of all images taken, in proportion. There was no statistical difference of patellar height index between the radiographics and tomographics images. CONCLUSION: The Insall-Salvati index in females was higher in all cases evaluated. Furthermore, it is possible to measure the patellar height index during tomographic study without distorting the results obtained, using to define the presence of patella alta or patella baja.

  10. Computer tomographic detection of an intraspinal arachnoidal cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kuckein, D; Walter, K; Paal, G

    1981-03-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location.

  11. Analysis of concrete material through gamma ray computerized tomography

    International Nuclear Information System (INIS)

    Oliveira Junior, J.M. de

    2004-01-01

    Computerized Tomography (CT) refers to the cross sectional imaging of an object from both transmission or reflection data collected by illuminating the object from many different directions. The most important contribution of CT is to greatly improve abilities to distinguish regions with different gamma ray transmittance and to separate over-lying structures. The mathematical problem of the CT imaging is that of estimating an image from its projections. These projections can represent, for example, the linear attenuation coefficient of γ-rays along the path of the ray. In this work we will present some new results obtained by using tomographic techniques to analyze column samples of concrete to check the distribution of various materials and structural problems. These concrete samples were made using different proportions of stone, sand and cement. Another set of samples with different proportions of sand and cement were also used to verify the outcome from the CT analysis and the differences between them. Those samples were prepared at the Material Laboratory of Faculdade de Engenharia de Sorocaba, following the same procedures used in real case of concrete tests. The projections used in this work was obtained by Mini Computerized Tomograph of Uniso (MTCU), located at the Experimental Nuclear Physics Laboratory at University of Sorocaba. This tomograph operates with a gamma ray source of 241 Am (photons of 60 keV and 100 mCi of intensity) and a NaI(Tl) solid state detector. The system features translation and rotation scanning modes, a 100 mm effective field of view, and 1 mm spatial resolution. The image reconstruction problem is solved using Discrete Filtered Backprojection (FBP). (author)

  12. Computer tomographic detection of an intraspinal arachnoidal cyst

    International Nuclear Information System (INIS)

    Kuckein, D.; Walter, K.; Paal, G.; Staedtisches Krankenhaus Harlaching, Muenchen

    1981-01-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location. (MG) [de

  13. Thoracic computerized tomographic (CT findings in 2009 influenza A (H1N1 virus infection in Isfahan, Iran

    Directory of Open Access Journals (Sweden)

    Mojtaba Rostami

    2011-01-01

    Full Text Available Background: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1 in an appropriate clinical setting. Methods: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23 rd 2009 to February 20 th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1 virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. Results: Patchy infiltration (34.6%, lobar consolidation (30.8%, and interstitial infiltration (26.9% with airbronchogram (38.5% were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8% showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS. Conclusions: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1 in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific.

  14. Dose profile study on computerized tomography scanning of skull with simulator object

    International Nuclear Information System (INIS)

    Mourao, A.P.

    2011-01-01

    This work presents a comparison among the dose profiles in scanning of computerized tomography of a simulator object of PMMA in its periphery region. To obtain the deposited dose at the PMMA thermoluminescent dosemeters were used positioned at the interior of PMMA simulated object longitudinal to periphery and at the center of cylinder (positions denominated North, South, East, West and Center). Eight scanning were performed of simulator object using the routine protocol for skull in eight different services of radiodiagnostic by TC

  15. Neurosurgical operating computerized tomographic scanner system

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi.

    1988-01-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place. (author)

  16. Multidetector computerized tomographic fistulography in the evaluation of congenital branchial cleft fistulae and sinuses.

    Science.gov (United States)

    Sun, Zhipeng; Fu, Kaiyuan; Zhang, Zuyan; Zhao, Yanping; Ma, Xuchen

    2012-05-01

    The aim of this study was to primarily investigate the usefulness of computerized tomographic (CT) fistulography in the diagnosis and management of branchial cleft fistulae and sinuses. Fifteen patients with confirmed branchial fistulae or sinuses who had undergone CT fistulography were included. The diagnoses were confirmed by clinical, radiologic, or histopathologic examinations. The internal openings, distribution, and neighboring relationship of the lesions presented by CT fistulography were analyzed to evaluate the usefulness in comparison with x-ray fistulography. Nine patients were diagnosed with first branchial fistulae or sinuses, 2 with second branchial fistulae, and 4 with third or fourth branchial fistulae. The presence and location of the lesions could be seen on x-ray fistulography. The distribution of the lesions, internal openings, and neighboring relationship with parotid gland, carotid sheath, and submandibular gland could be clearly demonstrated on CT cross-sectional or volume-rendering images. CT fistulography could provide valuable information and benefit surgical planning by demonstrating the courses of branchial anomalies in detail. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Computerized tomographic evaluation of primary brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Ok; Lee, Jong Soon; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Presbyterian Mediacal center, Cheonju (Korea, Republic of); Kim, Jong Deok [Inje Medical College, Paik Hospital, Pusan (Korea, Republic of)

    1985-10-15

    In a study of primary brain tumors 104 cases having satisfactory clinical, operative and histological proofs were analyzed by computerized tomography at Presbyterian Medical Center from May, 1982 to April 1985. The results were as follows: 1. The male to female ratio of primary brain tumor was 54 : 46. 2. The 2nd decade group (26%) was the most prevalent age group, followed by the 5th decade (16.3%), 1st decade (14.4%) , 3rd decade (12.5%), 4th decade (11.5%), 6th decade (10.6%), 7th decade (8.7%) in that order. 3. The incidence of primary brain tumors was found to be: glioma 64 cases (61.6%) among the GM, the most frequent 17 cases (16.3%), followed by meningioma 12 cases (11.5%), pituitary adenoma 10 cases (9.6%), craniopharyngioma 6 cases (5.8%), pinealoma and germinoma 3 cases (2.9%) respectively, and dermoid cyst 2 cases (1.9%) in that order. 4. The location of the primary brain tumors were as follows: cb. hemisphere (49%) of these 24.5% in parietal region, 11.9% in temporal region, 9.7% in frontal region, 3.0% in occipital region: juxtasella area (16.3%), cerebellar hemisphere (8.7%), parapineal and intraventricle (7.7%) respectively, cerebello-pontine angle area (5.8%), vermis and 4th ventricular region (4.8%). 5. There were no remarkable differences in the findings of pre- and post-contrast CT scanning of primary brain tumors computed with others.

  18. Computer tomographic examinations in epilepsy

    International Nuclear Information System (INIS)

    De Villiers, J.F.K.

    1984-01-01

    Epileptic patients that was examined at the Universitas Hospital (Bloemfontein) by means of computerized tomography for the period July 1978 - December 1980, are divided into two groups: a) Patients with general epilepsy of convulsions - 507; b) Patients with vocal or partial epilepsy - 111. The method of examination and the results for both general and vocal epilepsy are discussed. A degenerative state was found in 35% of the positive computer tomographic examinations in general epilepsy and 22% of the positive examinations for vocal epilepsy. The purpose of the article was to explain the circumstances that can be expected when a epileptic patient is examined by means of computerized tomography

  19. Orthopedic applications of single photon emission computed Tomographic bone scanning

    International Nuclear Information System (INIS)

    Collier, B.D.

    1987-01-01

    When compared with planar bone scanning, single photon emission computed tomography (SPECT) has technical advantages of potential diagnostic significance. Planar imaging often superimposes substantial underlying or overlying activity on the bony structure of medical interest. SPECT, however, can be used to remove such unwanted activity. For example, in the hip the acetabulum extends downwards behind the femoral head. Therefore when using planar bone scanning techniques, the photon-deficient defect typical of avascular necrosis (AVN) of the femoral had may be obscured by activity originating in the underlying acetabulum. By using SPECT, underlying and overlying distributions of activity can be separated into sequential tomographic planes. For this reason SPECT facilitates the detection of AVN of the femoral head. When referring a patient without a history of malignancy for bone scanning, the orthopaedic surgeon usually has a specific clinical question involving a limited portion of the skeleton. Orthopaedic surgeons at their institution commonly use bone scanning to clarify the cause of back, hip or knee pain; to determine with a physiological test the significance of radiographic findings; and to establish the extent of disease at symptomatic skeletal sites such as the three compartments of the knee. In instances such as these, when clinical concern is limited to a specific anatomical region, a bone scan procedure that includes SPECT imaging of only a portion of the skeleton is appropriate. To date, SPECT of the skeletal system has most frequently been used to evaluate patients with pain the larger joints and bony structures such as the lumbar spine, hips, knees, or temporomandibular joints (TMJ)

  20. Development of a computerized tomographic system

    International Nuclear Information System (INIS)

    Borges, J.C.; Santos, C.A.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory at COPPE/UFRJ has been developing techniques for detection and applications of nuclear radiations. A lot of research work has been done and resulted in several M.Sc. and D.Sc. thesis, concerning subjects like neutrongraphy, gammagraphy, image reconstruction, special detectors, etc. Recent progress and multiple applications of the computerized tomography to medical and industrial non-destructive tests, pushed the Laboratory to a vast program in this field of research. In this paper, we report what has been done and the results obtained. (Author) [pt

  1. Automated angular and translational tomographic alignment and application to phase-contrast imaging

    DEFF Research Database (Denmark)

    Cunha Ramos, Tiago Joao; Jørgensen, Jakob Sauer; Andreasen, Jens Wenzel

    2017-01-01

    X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object po...... improvement in the reconstruction resolution. A MATLAB implementation is made publicly available and will allow robust analysis of large volumes of phase-contrast tomography data.......X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object...... reconstruction artifacts and limit the attained resolution in the final tomographic reconstruction. Alignment algorithms that require manual interaction impede data analysis with ever-increasing data acquisition rates, supplied by more brilliant sources. We present in this paper an iterative reconstruction...

  2. Computerized tomographic evaluation of aortic prosthetic graft complications

    International Nuclear Information System (INIS)

    Kay, D.; Kalmar, J.A.

    1985-01-01

    Computerized tomography has been found to be an accurate and sensitive method of diagnosing complications of synthetic aortic grafts. Complications in this series of four cases included aortoesophageal fistula, aortoduodenal fistula, pseudoaneurysm, and retroperitoneal hematoma. 6 references, 5 figures

  3. Computerized three-dimensional normal atlas

    International Nuclear Information System (INIS)

    Mano, Isamu; Suto, Yasuzo; Suzuki, Masataka; Iio, Masahiro.

    1990-01-01

    This paper presents our ongoing project in which normal human anatomy and its quantitative data are systematically arranged in a computer. The final product, the Computerized Three-Dimensional Normal Atlas, will be able to supply tomographic images in any direction, 3-D images, and coded information on organs, e.g., anatomical names, CT numbers, and T 1 and T 2 values. (author)

  4. Computerized tomography in the diagnosis of mechanical jaundice

    International Nuclear Information System (INIS)

    Grushin, Yu.V.; Manasov, T.Zh.; Raskolenko, A.A.; Nazyrova, N.K.; Dzhumashev, E.Z.

    1987-01-01

    A total of 51 patients with suspected mechanical jaundice were examined using the 3rd generation computerized tomograph. A correct conclusion as to the level and mechanism of obstruction was made in 77% of cases. The most serious problems arose in analysis of extrahepatic biliary ducts. The dilatation of the biliary passages was not always combined with their obturation. In cases which were difficult for interpretation, additional information could be obtained by using thin tomographic layers, i.v. contrast enhancement, and retrograde endoscopic cholangiography

  5. Scanning tomographic particle image velocimetry applied to a turbulent jet

    KAUST Repository

    Casey, T. A.

    2013-02-21

    We introduce a modified tomographic PIV technique using four high-speed video cameras and a scanning pulsed laser-volume. By rapidly illuminating adjacent subvolumes onto separate video frames, we can resolve a larger total volume of velocity vectors, while retaining good spatial resolution. We demonstrate this technique by performing time-resolved measurements of the turbulent structure of a round jet, using up to 9 adjacent volume slices. In essence this technique resolves more velocity planes in the depth direction by maintaining optimal particle image density and limiting the number of ghost particles. The total measurement volumes contain between 1 ×106 and 3 ×106 velocity vectors calculated from up to 1500 reconstructed depthwise image planes, showing time-resolved evolution of the large-scale vortical structures for a turbulent jet of Re up to 10 000.

  6. Minimum Detectable Activity for Tomographic Gamma Scanning System

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Ram [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Smith, Susan [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Kirkpatrick, J. M. [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities

  7. Comparison of absorbed dose of two protocols of tomographic scanning in PET/CT exams

    International Nuclear Information System (INIS)

    Paiva, F.G.

    2017-01-01

    Positron Emission Tomography (PET) associated with Computed Tomography (CT) allows the fusion of functional and anatomical images. When compared to other diagnostic techniques, PET-CT subjects patients to higher levels of radiation, because two modalities are used in a single exam. In this study, the doses absorbed in 19 patient organs from the tomographic scan were evaluated. Radiochromic films were correctly positioned in the Alderson anthropomorphic simulator, male version. For evaluation, two whole body scan protocols were compared. For evaluation, two whole body scan protocols were compared. An increase of up to 600% in the absorbed dose in the pituitary was observed when the protocols were compared, with the lowest observed increase of approximately 160% for the liver. It is concluded that the dose from CT in patients submitted to PET-CT scanning is higher in the protocol used for diagnosis. Considering the high cost of PET-CT exam, in many cases it is preferable that the CT examination is of diagnostic quality, and not only for anatomical mapping, an argument based on the Principle of Justification

  8. Geometrical efficiency in computerized tomography: generalized model

    International Nuclear Information System (INIS)

    Costa, P.R.; Robilotta, C.C.

    1992-01-01

    A simplified model for producing sensitivity and exposure profiles in computerized tomographic system was recently developed allowing the forecast of profiles behaviour in the rotation center of the system. The generalization of this model for some point of the image plane was described, and the geometrical efficiency could be evaluated. (C.G.C.)

  9. Computerized tomographic evaluation of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Young; Lee, Mi Sook; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Precbyterian Medical Center, Chonju (Korea, Republic of)

    1988-08-15

    Cerebral cysticercosis, unfortunately frequent in Korea, is a parastic disease in which man serve as the intermediate host of taenia solium. The larvae have a predilection for the central nervous system and can cause a variety of neurologic symptoms. The authors reviewed 19 cases of surgically proven cerebral cysticercosis and following results were obtained. 1. The most frequent age distribution was 5th and 6th decade and male to female ratio was 14:5. 2. The most frevalent involving site was cerebral parenchyme and following by ventricles. 3. Clinical manifestations were symtom and sign of increased ICP, seizure and focal neurological dificit. 4. It was assumed that computerized tomography was the procedure of choice for the diagnosis of these parasitic brain disease.

  10. Radiation exposure distribution in patients undergoing CT brain scans

    International Nuclear Information System (INIS)

    Yang Zhanshan; Feng Dinghua; Chang Zichi; Li Shijun

    1989-12-01

    The distribution of surface exposures in patients undergoing single and multiple computerized tomographic brain scans with Hitachi CT-W500 was measured by LiF(Mg, Ti) thermoluminescent dosimetry. It was found that there was no significant difference in the sufrace exposures from different scanning slices. However, the exposure doses at different scanning angles around the head were different significantly. The reference point of the maximum surface exposure was at the temporal part of the head. the maximum surface exposure was at 1.65 x 10 -3 C·kg -1 while the average exposure was 1.55 x 10 -3 C·kg -1 . The ratio of the average dose resulting from nine scans to that from a single scan was 1.3, and the surface exposure contribution of scattered radiation was computed. At the same time the radiation doses to eyes, thyroid, chest and gonads of patiens at corresponding position were also measured and were compared with those from CT cranial scans in children and skull radiographic procedures respectively

  11. Computerized spleen volumetry

    International Nuclear Information System (INIS)

    Jahnke, T.; Mohring, R.; Schertel, L.

    1981-01-01

    We examined in experimental studies and clinical investigations on 34 patients in how far volumetry of the spleen can be carried out with a commonly available program, a whole-body computerized tomograph (SOMATOM) and an analytic equipment (EVALUSKOP). In this connection the authors tried to find also other ways of spleen volumetry by means of this unit combination. Our final result was that the given program for the usage of labelled areas presents itself as the best-suited technique for spleen volumetry which is also applicable in practice. (orig./MG) [de

  12. Tomographic apparatus for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus which can be used in computerized tomographic systems for producing a fan shaped beam, detectors to be used in conjunction with the source and equipment for rotating the source supports are described. (U.K.)

  13. Ultrasonic and computerized tomographic semiotics of cholelithiasis

    International Nuclear Information System (INIS)

    Kishkovskij, A.N.; Kuznetsov, S.V.; Fadeev, V.D.

    1986-01-01

    Altogether 447 patients with suspected cholelithiasis were examined by means of routine X-ray methods, ultrasound (US) and computerized tomography (CT).Of them in 104 (23.3%) chole- and/or choledocholithiasis were later confirmed. An US and CT-picture of the biliferous tracts in health were described.In cholelithiasis during US examination echogenic concrements producing a stable acoustic shadow were defined in the gall bladder cavity and/or in the biliferous ducts. A study was made of the features of the US picture with relation to size, quantity, echodensity and grouping of concrements in the biliferous ducts. CT-symptomatology of cholelithiasis was described

  14. Anti-inflamatory effect and objective evaluation of naproxen in osteoarthritis by computerized scintillation scanning

    International Nuclear Information System (INIS)

    Scheinberg, M.A.; Schainberg, H.; Diniz, R.; Nunes, A.P.; Marone, M.; Hasson, R.; Lewin, S.

    1985-01-01

    The anti-inflammatory effect of naproxen, a non-steroidal anti-inflammatory drug, in osteoarthritis was evaluated through subjective clinical and objective computerized scintigraphic scanning parameters. All patients received 1.0g daily of naproxen administered once a day in the morning during six weeks. Twenty patients were evaluated clinically and the results were favourable in 19 (95%) with complete symptoms disappearance in 9 (45%). Sixteen patients were evaluated through the computerized scintilography, and a significant reduction in the articular flow was observed in 11 patients (68.75%). Side effects were few, mild to moderate, the majority related to G.I. tract, and in none patient was necessary treatment interruption. It is concluded that naproxen is a useful agent in the treatment of osteoarthritis and the correspondent inflamation associated with the basic mechanisms of the disease. (author) [pt

  15. Evaluation of brain scintigraphy and computerized tomography

    International Nuclear Information System (INIS)

    Cavailloles, F.; Dairou, R.; Desbleds, M.T.; Benoit, C.; Larmande, P.; Bok, B.; Alperovitch, A.

    1983-01-01

    In order to assess the clinical usefulness of brain computerized tomography and radionuclide scan, a prospective study was performed on a series of 554 patients. The detection rate was assessed as well as the identification rate of lesions. In addition, the usefulness of both tests was appreciated subjectively by two neurologists reviewing the patients' files. Both give reasonably similar results: computerized tomography is superior to radionuclide scan in the diagnosis of tumors and intracerebral hematomas, the radionuclide scan being slightly superior in the diagnosis of purely ischemic CVA and subdural hematomas. The superiority which was subjectively conceded to computerized tomography was greater than that objectively demonstrated. However, clinical usefulness of computerized tomography was judged important in only 50% of the cases. Moreover, to request both computerized tomography and radionuclide scan appeared as having no interest in 83% of the cases. In that series, the diagnostic hypotheses were in agreement with the final diagnosis in 88% of the cases. Bias encountered in this type of studies are discussed [fr

  16. The Study on Radioactive Nuclide Distributions within a Fuel Rod by Tomographic Gamma Scanning Method

    International Nuclear Information System (INIS)

    Quanhu, Zhang; Lee, H. K.; Hong, K. P.; Choo, Y. S.; Kim, D. S.

    2005-06-01

    Based on the specified need of the IMEF, the feasibility of Tomographic Gamma Scanning (TGS) technique has been investigated for its potential for non-destructive gamma scanning measurements of irradiated fuel rods. TGS technique has been developed for determining some radioactive isotopes' distributions of a fuel rod in hot cell. The results obtained from the simulation model extracting from real gamma scanning experimental condition in this work by new developed computer simulation codes confirmed that the gamma emission TGS technique has potential for determination of radioactive isotopes' distributions of a fuel rod. In order to verify the simulation codes, we have designed several computation schemes for both 3 by 3 and 10 by 10 fuel rod model under present situation at M1 hot cell in IMEF. The results which relative errors are less than 10% show that we have simulated and implemented determination of radioactive isotopes' distributions on simulated fuel rod by TGS technique successfully

  17. Computerized tomographic findings of hepatic fascioliasis compared with melioidosis-caused liver abscesses.

    Science.gov (United States)

    Chamadol, Nittaya; Laopaiboon, Vallop; Techasatian, Pennapa; Sukeepaisanjaroen, Wattana; Sripanuskul, Anan

    2010-07-01

    To compare the computerized tomographic (CT) findings of hepatic fascioliasis (HF) vs. melioidosis-caused liver (ML) abscesses. CT images of 15 patients with hepatic fascioliasis (HF) and 16 patients with melioidosis-caused liver (ML) abscesses were retrospectively reviewed. The authors evaluated and compared HF and ML abscesses (by chi2 and Fisher exact tests) vis-a-vis their location of liver involvement, size, shape, number margins, enhancement patterns, subcapsular lesions, internal architecture, dilatation of intrahepatic bile duct and combination with splenic abscesses. Fourteen HF patients had only liver abscesses and 1 had combined liver and splenic abscesses. Four ML patients had liver abscesses alone while 12 had combined liver and splenic abscesses (p = 0.000). Eight of the 15 HF (53.3%) and 2 of the 16 ML (12.5%) patients had subcapsular lesions (p = 0.019). The liver abscesses were round or oval with linear tracts in 8 of the 15 HF (53.3%) and none of the ML patients (p = 0.001). Between the respective HF and ML patients, there was a significant difference in those with round shaped in ML (p = 0.008), multiple and conglomerately distributed in HF (p = 0.050), multiple and discretely distributed in ML (p = 0.001) no (or minimal) peripheral contrast enhancement in HF (p = 0.011) and moderate or mark peripheral enhancement in ML (p = 0.011). The CT findings of liver abscesses that helped to differentiate hepatic fascioliasis from melioidosis liver abscesses were: their number shape, enhancement pattern, presence of subcapsular lesion (s) and co-occurrence with splenic abscesses. The diagnosis of hepatic fascioliasis by CT is suggested when the following characteristics were seen: (1) multiple, small round or oval (with linear tracts) conglomerates presenting as hypodense lesions; (2) no (or minimal) peripheral contrast enhancement; (3) subcapsular lesions; or (4) less frequent co-occurrence with splenic abscesses.

  18. Construction of Korean male tomographic model segmented from PET-CT data

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Park, Sang Kyun; Lee, Jai Ki

    2004-01-01

    Tomographic human models provide currently the most realistic representation of human anatomy for radiation dosimetry calculation. Most of the models have been constructed by using computed tomographic (CT) or magnetic resonance (MR) images obtained from a single individual. Each scan has its inherent advantages and disadvantages. CT scan gives a considerable radiation dose to a subject, and MR scan takes too long time to get clear images of an immobile subject. An emerging source of medical images for the construction of tomographic models is PET-CT, which is performed when looking for cancer. In this study, a tomographic model of Korean adult male was developed by processing whole-body CT images of a PET-CT-scanned healthy volunteer. The 343 slices of the CT images were semi-automatically segmented layer by layer using a graphic software and screen digitizer. The 3rd Korean tomographic model, named KRMAN-2, consisting of 300x150x344 voxels of a size of 2x2x5mm 3 , was constructed. Examples of application to Monte Carlo radiation dosimetry calculation in idealized whole-body irradiations were given and discussed

  19. Quantitative inspection by computerized tomography

    International Nuclear Information System (INIS)

    Lopes, R.T.; Assis, J.T. de; Jesus, E.F.O. de

    1989-01-01

    The computerized Tomography (CT) is a method of nondestructive testing, that furnish quantitative information, that permit the detection and accurate localization of defects, internal dimension measurement, and, measurement and chart of the density distribution. The CT technology is much versatile, not presenting restriction in relation to form, size or composition of the object. A tomographic system, projected and constructed in our laboratory is presented. The applications and limitation of this system, illustrated by tomographyc images, are shown. (V.R.B.)

  20. Positron emission tomographic scan investigations of Huntington's disease: cerebral metabolic correlates of cognitive function

    International Nuclear Information System (INIS)

    Berent, S.; Giordani, B.; Lehtinen, S.; Markel, D.; Penney, J.B.; Buchtel, H.A.; Starosta-Rubinstein, S.; Hichwa, R.; Young, A.B.

    1988-01-01

    Fifteen drug-free patients with early to mid-stage Huntington's disease (HD) were evaluated with positron emission tomographic (PET) scans of 18 F-2-fluoro-2-deoxy-D-glucose uptake and quantitative measures of neurological function, learning, memory, and general intelligence. In comparison with a group of normal volunteers, the HD patients showed lower metabolism in both caudate (p less than 0.001) and putamen (p less than 0.001) on PET scans. A significant and positive relationship was found between neuropsychological measures of verbal learning and memory and caudate metabolism in the patient group but not in the normal group. Visual-spatial learning did not reflect a similar pattern, but performance intelligence quotient was positively related to both caudate and putamen metabolism in the HD group. Vocabulary level was unrelated to either brain structure. Discussion focuses on these and other observed brain-behavior relationships and on the implications of these findings for general behaviors such as those involved in coping and adaptation

  1. Computerized tomographic simulation compared with clinical mark-up in palliative radiotherapy: A prospective study

    International Nuclear Information System (INIS)

    Haddad, Peiman; Cheung, Fred; Pond, Gregory; Easton, Debbie; Cops, Frederick; Bezjak, Andrea; McLean, Michael; Levin, Wilfred; Billingsley, Susan; Williams, Diane; Wong, Rebecca

    2006-01-01

    Purpose To evaluate the impact of computed tomographic (CT) planning in comparison to clinical mark-up (CM) for palliative radiation of chest wall metastases. Methods and Materials In patients treated with CM for chest wall bone metastases (without conventional simulation/fluoroscopy), two consecutive planning CT scans were acquired with and without an external marker to delineate the CM treatment field. The two sets of scans were fused for evaluation of clinical tumor volume (CTV) coverage by the CM technique. Under-coverage was defined as the proportion of CTV not covered by the CM 80% isodose. Results Twenty-one treatments (ribs 17, sternum 2, and scapula 2) formed the basis of our study. Due to technical reasons, comparable data between CM and CT plans were available for 19 treatments only. CM resulted in a mean CTV under-coverage of 36%. Eleven sites (58%) had an under-coverage of >20%. Mean volume of normal tissues receiving ≥80% of the dose was 5.4% in CM and 9.3% in CT plans (p = 0.017). Based on dose-volume histogram comparisons, CT planning resulted in a change of treatment technique from direct apposition to a tangential pair in 7 of 19 cases. Conclusions CT planning demonstrated a 36% under-coverage of CTV with CM of ribs and chest wall metastases

  2. Is triple contrast computed tomographic scanning useful in the selective management of stab wounds to the back?

    Science.gov (United States)

    McAllister, E; Perez, M; Albrink, M H; Olsen, S M; Rosemurgy, A S

    1994-09-01

    We devised a protocol to prospectively manage stab wounds to the back with the hypothesis that the triple contrast computed tomographic (CT) scan is an effective means of detecting occult injury in these patients. All wounds to the back in hemodynamically stable adults were locally explored. All patients with muscular fascial penetration underwent triple contrast CT scanning utilizing oral, rectal, and IV contrast. Patients did not undergo surgical exploration if their CT scan was interpreted as negative or if the CT scan demonstrated injuries not requiring surgical intervention. Fifty-three patients were entered into the protocol. The time to complete the triple contrast CT scan ranged from 3 to 6 hours at a cost of $1050 for each scan. In 51 patients (96%), the CT scan either had negative findings (n = 31) or showed injuries not requiring exploration (n = 20). These patients did well with nonsurgical management. Two CT scans documented significant injury and led to surgical exploration and therapeutic celiotomies. Although triple contrast CT scanning was able to detect occult injury in patients with stab wounds to the back it did so at considerable cost and the results rarely altered clinical care. Therefore, its routine use in these patients is not recommended.

  3. Tomographic imaging of matter using primary and secondary X-and gamma-radiation

    International Nuclear Information System (INIS)

    Holloway, I.E.

    1991-04-01

    Gamma rays may interact with matter by a variety of processes, many of which give rise to secondary radiations. This thesis examines the possibility of performing tomographic imaging by means of these secondary photons using low-cost apparatus. The techniques are compared with each other and with transmission tomography, which plays such an important role in modern diagnostic imaging. The progress of industrial tomography is reviewed as are techniques of investigation using gamma ray scattering in both industry and medicine. Some new applications of a simple gamma ray computerized tomography (CT) scanner have been performed. A method of determining the spatial distribution of pure beta emitters in matter by performing tomographic imaging using the bremsstrahlung radiation produced by the beta particles has been demonstrated. This technique has been shown to permit imaging at depths in material greatly exceeding the range of beta particles in matter. All the imaging techniques using secondary radiation have displayed two principal limitations: long scanning times and poor quantitative accuracy. The low scanning rate results from the small number of secondary photons that are detected. The major contributing factors to poor accuracy are attenuation and the noise produced by unwanted in-scattering. The possible applications for secondary photon imaging have been briefly outlined and some suggestions for future work are included. Although techniques based upon imaging using secondary radiation will not be able to compete with transmission CT in the vast majority of applications, they may prove valuable in a range of specialised fields. (author)

  4. X-rays computed tomographic scans of lower limb and trunk muscles in facioscapulohumeral muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Horikawa, Hirosei; Mano, Yukio; Takayanagi, Tetsuya [Nara Medical Univ., Kashihara (Japan); Takahashi, Keiichi; Nishio, Hisahide

    1992-10-01

    X-rays computed tomographic (CT) scans of muscles of the lower limbs and the trunk in 14 patients with facioscapulohumeral muscular dystrophy (FSH) were studied. The CT scans showed that the affected muscles were decreased in density and size. The laterality of muscular involvement was sometimes observed. The muscular lesions in the lower limbs showed proximal distribution. In the thigh, the hamstrings were affected first, the adductor muscles second, and then the muscular involvement progressed to the quadriceps femoris muscle. In the lower leg, the gastrocnemius and soleus muscles were relatively spared as compared with the tibialis anterior muscle. In the lumbar girdle, the abdominal muscles were involved first, the gluteal muscles second, the back muscles third, and the psoas major muscle were relatively spared. The muscular weakness of this distribution exacerbated lumbar lordosis. The neck muscles were less affected than those of the lumbar girdle. The CT scans in FSH demonstrated the characteristic pattern of muscular involvement, which differed from the inherited muscular diseases such as Duchenne muscular dystrophy, myotonic dystrophy, and others. (author).

  5. X-rays computed tomographic scans of lower limb and trunk muscles in facioscapulohumeral muscular dystrophy

    International Nuclear Information System (INIS)

    Horikawa, Hirosei; Mano, Yukio; Takayanagi, Tetsuya; Takahashi, Keiichi; Nishio, Hisahide.

    1992-01-01

    X-rays computed tomographic (CT) scans of muscles of the lower limbs and the trunk in 14 patients with facioscapulohumeral muscular dystrophy (FSH) were studied. The CT scans showed that the affected muscles were decreased in density and size. The laterality of muscular involvement was sometimes observed. The muscular lesions in the lower limbs showed proximal distribution. In the thigh, the hamstrings were affected first, the adductor muscles second, and then the muscular involvement progressed to the quadriceps femoris muscle. In the lower leg, the gastrocnemius and soleus muscles were relatively spared as compared with the tibialis anterior muscle. In the lumbar girdle, the abdominal muscles were involved first, the gluteal muscles second, the back muscles third, and the psoas major muscle were relatively spared. The muscular weakness of this distribution exacerbated lumbar lordosis. The neck muscles were less affected than those of the lumbar girdle. The CT scans in FSH demonstrated the characteristic pattern of muscular involvement, which differed from the inherited muscular diseases such as Duchenne muscular dystrophy, myotonic dystrophy, and others. (author)

  6. Tomographic apparatus and method for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    An apparatus is described which can be used in computerized tomographic systems for constructing a representation of an object and which uses a fan-shaped beam source, detectors and a convolution method of data reconstruction. (U.K.)

  7. Evaluation of quality of tomographs of Rio de Janeiro state, Brazil

    International Nuclear Information System (INIS)

    Travassos, P.C.B.; Belem, V.R.; Magalhaes, L.A.; Almeida, C.E.A. de

    2014-01-01

    Computerized tomographs used in 56 institutions in the state of Rio de Janeiro were evaluated. Criteria of image quality and dosimetry were submitted. The results showed that some not performed optimize their protocols examinations or perform wrongly, which results in an increase in the dose received by patients, and an image in compromised quality. (author)

  8. Regrowth patterns of supratentorial gliomas: estimation from computed tomographic scans

    International Nuclear Information System (INIS)

    Tsuboi, K.; Yoshii, Y.; Nakagawa, K.; Maki, Y.

    1986-01-01

    To clarify the regrowth patterns of benign and malignant gliomas, we chose 27 intervals (between two operations or between an operation and autopsy) from 21 patients with pathologically verified recurrent supratentorial gliomas. Serial computed tomographic (CT) scans of these cases were analyzed to determine the doubling time (Td) calculated from the change in volume of enhanced and low density areas, the enhancement effect graded from 0 to 4 according to the Hounsfield number, and the presence of dissemination and contralateral extension. We studied 5 benign gliomas (including 1 case of radiation necrosis), 8 malignant astrocytomas, and 8 glioblastomas. The Td's of enhanced areas on CT scans of benign gliomas, malignant astrocytomas, and glioblastomas were 937 +/- 66.5 days, 65.1 +/- 29.4 days, and 48.1 +/- 20.9 days, respectively. The Td's of low density areas were 895 +/- 130.6 days, 70.8 +/- 22.2 days, and 50.5 +/- 14.7 days. There was a significant correlation between the Td's of the enhanced and low density areas (0.97). The enhancement effect increased at recurrence in 55% of the cases, with an average increase of 1.1 grades. The increase in enhancement effect at recurrence showed a tendency to become smaller as the tumor's degree of anaplasia increased. Radiotherapy was effective in significantly retarding the growth rate of malignant gliomas, whose Td's were doubled. Although the Td's of both enhanced and low density areas of benign gliomas were significantly longer than those of malignant gliomas, there was no significant difference in the Td's of enhanced areas between malignant astrocytomas and glioblastomas

  9. Transient ischemic attacks with and without a relevant infarct on computed tomographic scans cannot be distinguished clinically. Dutch Transient Ischemic Attack Study Group

    NARCIS (Netherlands)

    Koudstaal, P. J.; van Gijn, J.; Lodder, J.; Frenken, W. G.; Vermeulen, M.; Franke, C. L.; Hijdra, A.; Bulens, C.

    1991-01-01

    We prospectively studied clinical and computed tomographic (CT) scan findings in 79 patients with a transient ischemic attack (TIA) and a relevant cerebral infarction on CT, also known as cerebral infarction with transient signs (CITS). We compared the results with those of 527 concurrent patients

  10. Regrowth patterns of supratentorial gliomas: estimation from computed tomographic scans

    Energy Technology Data Exchange (ETDEWEB)

    Tsuboi, K.; Yoshii, Y.; Nakagawa, K.; Maki, Y.

    1986-12-01

    To clarify the regrowth patterns of benign and malignant gliomas, we chose 27 intervals (between two operations or between an operation and autopsy) from 21 patients with pathologically verified recurrent supratentorial gliomas. Serial computed tomographic (CT) scans of these cases were analyzed to determine the doubling time (Td) calculated from the change in volume of enhanced and low density areas, the enhancement effect graded from 0 to 4 according to the Hounsfield number, and the presence of dissemination and contralateral extension. We studied 5 benign gliomas (including 1 case of radiation necrosis), 8 malignant astrocytomas, and 8 glioblastomas. The Td's of enhanced areas on CT scans of benign gliomas, malignant astrocytomas, and glioblastomas were 937 +/- 66.5 days, 65.1 +/- 29.4 days, and 48.1 +/- 20.9 days, respectively. The Td's of low density areas were 895 +/- 130.6 days, 70.8 +/- 22.2 days, and 50.5 +/- 14.7 days. There was a significant correlation between the Td's of the enhanced and low density areas (0.97). The enhancement effect increased at recurrence in 55% of the cases, with an average increase of 1.1 grades. The increase in enhancement effect at recurrence showed a tendency to become smaller as the tumor's degree of anaplasia increased. Radiotherapy was effective in significantly retarding the growth rate of malignant gliomas, whose Td's were doubled. Although the Td's of both enhanced and low density areas of benign gliomas were significantly longer than those of malignant gliomas, there was no significant difference in the Td's of enhanced areas between malignant astrocytomas and glioblastomas.

  11. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors

    OpenAIRE

    Tong Yu; Jun Gao; Zhi-Min Liu; Qi-Feng Zhang; Yong Liu; Ling Jiang; Yun Peng

    2017-01-01

    Background: Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors...

  12. Computerized tomography of adrenal glands in the investigation of Cushing's syn

    International Nuclear Information System (INIS)

    Abucham Filho, J.; Albertotti, C.; Kater, C.E.; Vieira, J.G.H.; Chacra, A.R.

    1983-01-01

    Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author) [pt

  13. A Mobile Automated Tomographic Gamma Scanning System - 13231

    Energy Technology Data Exchange (ETDEWEB)

    Kirkpatrick, J.M.; LeBlanc, P.J.; Nakazawa, D.; Petroka, D.L.; Kane Smith, S.; Venkataraman, R.; Villani, M. [Canberra Industries, Inc. 800 Research Parkway, Meriden CT 06450 (United States)

    2013-07-01

    Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 ke

  14. Investigating the correlation between computerized tomography changes and quantitative consciousness disturbances in stroke patients

    International Nuclear Information System (INIS)

    Toneva, Yu.; Manchev, I.; Tsolova, M.

    1997-01-01

    One-hundred and nine patients undergo computerized tomographic (CT) and clinical investigations. The correlation between CT finding and quantitative consciousness disturbances has been studied. The somatic, neurologic and mental states are evaluated, and the changes in consciousness are classified according to a 4-degree rating system adopted in this country, namely: obnubilation, somnolence, sopor and coma. For the purpose a computerized tomograph CE 10000 is used. Cerebral infarctions in the right middle cerebral artery pool predominate. Here the disturbances are of a milder degree - obnubilation and somnolence. In stroke syndrome cases the states of sopor and coma are more frequent which may be explained with the rather severely manifested brain edema. In either form of cerebrovascular disease the quantitative disorders of consciousness are not dependent on the location of the accident in the dominant hemisphere. They are directly related to the CT documented size of pathological focus

  15. Coupling two iteratives algorithms for density measurements by computerized tomography

    International Nuclear Information System (INIS)

    Silva, L.E.M.C.; Santos, C.A.C.; Borges, J.C.; Frenkel, A.D.B.; Rocha, G.M.

    1986-01-01

    This work develops a study for coupling two iteratives algotithms for density measurements by computerized tomography. Tomographies have been obtained with an automatized prototype, controled by a microcomputer, projected and assembled in the Nuclear Instrumentation Laboratory, at COPPE/UFRJ. Results show a good performance of the tomographic system, and demonstrate the validity of the method of calculus adopted. (Author) [pt

  16. Detection of the source of hemorrhage using postmortem computerized tomographic angiography in a case of a giant juvenile nasopharyngeal angiofibroma after surgical treatment.

    Science.gov (United States)

    do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais

    2015-09-01

    Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.

  17. The use of transport and diffusion equations in the three-dimensional reconstruction of computerized tomographic images

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Sandrerley Ramos, E-mail: sandrerley@eee.ufg.br [Escola de Engenharia Eletrica e de Computacao - EEEC, Universidade Federal de Goias - UFG, Goiania, GO (Brazil); Flores, Edna Lucia; Pires, Dulcineia Goncalves F.; Carrijo, Gilberto Arantes; Veiga, Antonio Claudio Paschoarelli [Faculdade de Engenharia Eletrica - FEELT, Universidade Federal de Uberlandia - UFU, Uberlandia, MG (Brazil); Barcelos, Celia Aparecida Z. [Faculdade de Matematica, Universidade Federal de Uberlandia - UFU, Uberlandia, MG (Brazil)

    2012-09-15

    The visualization of a computerized tomographic (TC) exam in 3D increases the quality of the medical diagnosis and, consequently, the success probability in the treatment. To obtain a high quality image it is necessary to obtain slices which are close to one another. Motivated towards the goal of reaching an improved balance between quantity of slices and visualization quality, this research work presents a digital inpainting technique of 3D interpolation for CT slices used in the visualization of human body structures. The inpainting is carried out via non-linear partial differential equations (PDE). The PDE's have been used, in the image-processing context to fill in the damaged regions in a digital 2D image. Inspired by this idea, this article proposes an interpolation method for the filling in of the empty regions between the CT slices. To do it, considering the high similarity between two consecutive real slice, the first step of the proposed method is to create the virtual slices. The virtual slices contain all similarity between the intercalated slices and, when there are not similarities between real slices, the virtual slices will contain indefinite portions. In the second step of the proposed method, the created virtual slices will be used together with the real slices images, in the reconstruction of the structure in three dimensions, mapped onto the exam. The proposed method is capable of reconstructing the curvatures of the patient's internal structures without using slices that are close to one another. The experiments carried out show the proposed method's efficiency. (author)

  18. Computed-tomographic determination of mineral content of bones

    International Nuclear Information System (INIS)

    Delov, I.; Tabakov, S.

    1988-01-01

    The problem of precise computed-tomographic densitometry of the mineral content of bones is pointed out. A method is proposed including the use of standard density and observance of definite radiation, scanning and image estimation parameters. A good correlation of the results obtained for the mineral content of the lumbar vertebrae with literature data are reported. A method is also described for determining the mineral content of tubular bones based on densiprofile check-up of the computed-tomographic density. The procedure takes 10-15 minutes and includes 1 or 2 scans. It might therefore gain wide acceptance for the diagnosis and tracing of osteoporosis and other osteopathies associated with distrorted calcium metabolism

  19. Standard test method for nondestructive assay of radioactive material by tomographic gamma scanning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method describes the nondestructive assay (NDA) of gamma ray emitting radionuclides inside containers using tomographic gamma scanning (TGS). High resolution gamma ray spectroscopy is used to detect and quantify the radionuclides of interest. The attenuation of an external gamma ray transmission source is used to correct the measurement of the emission gamma rays from radionuclides to arrive at a quantitative determination of the radionuclides present in the item. 1.2 The TGS technique covered by the test method may be used to assay scrap or waste material in cans or drums in the 1 to 500 litre volume range. Other items may be assayed as well. 1.3 The test method will cover two implementations of the TGS procedure: (1) Isotope Specific Calibration that uses standards of known radionuclide masses (or activities) to determine system response in a mass (or activity) versus corrected count rate calibration, that applies to only those specific radionuclides for which it is calibrated, and (2) Respo...

  20. Clinical, endocrinological, and computerized tomography scans for symmetrical calcification of the basal ganglia

    International Nuclear Information System (INIS)

    Goldscheider, H.G.; Lischewski, R.; Claus, D.; Streibl, W.; Waiblinger, G.; Ulm Univ., Schwendi/Dietenbronn; Ulm Univ.

    1980-01-01

    Symmetrical calcification of the basal ganglia was found in 2 promille of 8000 computerized tomography (CT) scans. Of 19 cases, only 2 were detectable on conventional skull films. The less prominent calcifications were most often found in the region of the pallidum, the knee of the internal capsule. Also, the lesions were generally symmetrical. Thus these factors must be considered basic morphological characteristics of the pathophysiological process. Additional neurological disorders were present in 6 patients. Neurological symptoms in the remaining 13, when present, depended on the extent of the lesion. The most common finding was tremor, although disturbances of fine motor control, transient lateralizing signs, and seizures were also noted. No particular constellation of symptoms or signs permitted accurate clinical localization of the lesions. (orig./AJ) [de

  1. Time to Computerized Tomography Scan, Age, and Mortality in Acute Stroke.

    Science.gov (United States)

    Myint, Phyo Kyaw; Kidd, Andrew C; Kwok, Chun Shing; Musgrave, Stanley D; Redmayne, Oliver; Metcalf, Anthony K; Ngeh, Joseph; Nicolson, Anne; Owusu-Agyei, Peter; Shekhar, Raj; Walsh, Kevin; Day, Diana J; Warburton, Elizabeth A; Bachmann, Max O; Potter, John F

    2016-12-01

    Time to computerized tomography (CT) is important to institute appropriate and timely hyperacute management in stroke. We aimed to evaluate mortality outcomes in relation to age and time to CT scan. We used routinely collected data in 8 National Health Service trusts in East of England between September 2008 and April 2011. Stroke cases were prospectively identified and confirmed. Odds ratios (ORs) for unadjusted and adjusted models for age categories (24 hours) and in-hospital and early (<7 days) mortality outcomes were calculated. Of the 7693 patients (mean age 76.1 years, 50% male) included, 1151 (16%) died as inpatients and 336 (4%) died within 7 days. Older patients and those admitted from care home had a significantly longer time from admission until CT (P < .001). Patients who had earlier CT scans were admitted to stroke units more frequently (P < .001) but had higher in-patient (P < .001) and 7-day mortality (P < .001). Whereas older age was associated with increased odds of mortality outcomes, longer time to CT was associated with significantly reduced mortality within 7 days (corresponding ORs for the above time periods were 1.00, .61 [95% confidence interval {CI}: .39-.95], .39 [.24-.64], and .16 [.08-.33]) and in-hospital mortality (ORs 1.00, .86 [.64-1.15], .57 [.42-.78] and .71 [.52-.98]). Older age was associated with a significantly longer time to CT. However, using CT scan time as a benchmarking tool in stroke may have inherent limitations and does not appear to be a suitable quality marker. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. Computerized tomography in diagnosis of cerebrocranial injury

    International Nuclear Information System (INIS)

    Kornienko, V.N.; Vasin, N.Ya.; Kuz'menko, V.A.

    1987-01-01

    The method of computerized tomographical examination are presented. Th KT-characters of concussion of the brain, its contusion of different severity, compressions in case of traumatic intracranial hematomas, contusion injuries, brain edema and different aftereffects of cerebrocranial injury are given. On the basis of comparison of the data of clinical and KT examination the dynamics of intracranial traumatic injuries in the course of treatment is described. The problems of therapeutic and surgical tactics depending on the degree and form of intracranial structure injuries and the phase of clinical course of posttraumatic process are discussed

  3. Arbitrary layer tomographic method and apparatus

    International Nuclear Information System (INIS)

    Kato, H.; Ishida, M.

    1984-01-01

    Many two-dimensional X-ray projection distribution images obtained by exposing an object to X-rays in various directions are once stored in positions different from one another in a stimulable phosphor sheet or respectively in many stimulable phosphor sheets. The stimulable phosphor sheet or sheets are then scanned with stimulating rays, and the light emitted thereby from the stimulable phosphor sheet or sheets is photoelectrically read out to obtain electric signals representing the X-ray projection distribution images. The electric signals are processed to obtain a tomographic image of an arbitrary tomographic layer of the object

  4. Substernal thyroid carcinoma detected by 67Ga scan in a patient with normal 131I scan

    International Nuclear Information System (INIS)

    Kim, e.E.; Maruyama, Y.; Deland, F.H.

    1978-01-01

    A patient with a superior mediastinal mass on an admission chest radiograph was initially evaluated by an 131 I thyroid scan which failed to demonstrate a substernal thyroid. However, the tomographic 67 Ga scan clearly showed an abnormal uptake in the area corresponding to the mass lesion on radiographic examination. Subsequent resection and biopsy of the substernal mass revealed a poorly differentiated follicular carcinoma with foci of anaplastic carcinoma. The differential diagnosis of the anterior mediastinal mass and the usefullness of the tomographic gallium scan are briefly discussed

  5. Clinical observations of the brain abscesses, especially on the computed tomographic brain scan findings

    International Nuclear Information System (INIS)

    Kitano, Masahiko; Kuroda, Ryotaro; Yamada, Yasufumi; Yorimae, Akira; Akai, Fumiharu; Watanabe, Masaru; Nakatani, Jiro; Ioku, Masahiko

    1988-01-01

    Fifteen cases with pyogenic brain abscess were experienced in our clinic during the last 7 years. The records of these patients were examined to evaluate the clinical stage and the result of several treatments. In 12 operative cases, diagnosis was made by fluid aspirated from the abscess. Bacteria were cultured from the fluid in 5 among these cases. In 3 other non-operative patients, diagnosis was based on computed tomographic (CT) brain scans and laboratory studies. Each volume of the brain abscess and surrounding brain edema was measured on serial CT scans to evaluate the clinical stage and the abscess evolution. In symptoms and signs, it has been thought that one of the factors contributing to mortality was the level of consciousness. In this study, the disturbance of consciousness did not correlate with the size of abscess, but with that of edema. The cases reported here were divided into 3 groups according to the volume of abscess and of edema on initial CT scans. The cases of group A had small surrounding edema ( 50 ml) and small abscess ( 25 ml). The group A had slight change in the clinical status and the size of edema, but the others had severe change. Three phase changes in edema size were seen in the group B regardless of therapeutic modalities ; showing almost constant increase in first 2 weeks, great decrease in second 2 weeks and moderate decrease following these 4 weeks. In the group C, however, these phases were seen only in early operation cases. (J.P.N.)

  6. Cranial computerized tomography aspects of neuro-cysticercosis in infancy

    International Nuclear Information System (INIS)

    Guerreiro, M.M.; Facure, N.O.; Guerreiro, C.A.M.

    1989-01-01

    The analysis of 27 computed tomography scans (CT) is presented. Eighteen children were divided in three groups according to clinical and tomographic criteria. Group 1 was characterized mainly by epilepsy and calcifications. Group 2 was characterized by intracranial hypertension and several tomographic aspects: edema, cysts and nodules were seen in three patients; hydrocephaly and calcifications were seen in two patients and CT was normal is one patient. Group 3 had patients with epilepsy or headache and variable tomographic patterns. The results are discussed based on the available literature. (author)

  7. Clinical value of computerized tomography scanning in severe head injury

    International Nuclear Information System (INIS)

    Kobayashi, Shiro; Yano, Masami; Otsuka, Toshibumi; Nakazawa, Shozo

    1982-01-01

    Serial computerized tomography (SCT) was performed on 138 patients suffering from severe head injuries (8 or less on the Glasgow Coma Scale). Standard practice called for scans to be done upon admission (within hours of the injury), and after 1, 3, 7 days and 1 month. Subsequent CT's depended on the patient's condition. Clinical results at the time of discharge were graded according to the Glasgow Outcome Scale. Patients who died, were in a persistent vegetative state, or were severely disabled were considered to have a ''bad outcome''. On the other hand, patients who were somewhat disabled or made good recoveries were considered to have a ''good outcome''. During the serial CT scan, there were new findings (not visualized on the initial CT but appearing on subsequent ones) in 91 of the 138 patients. These new findings were classified as follows; 1) decreased density collection in the subdural space (DDC), 2) ventricular dilation (VD), 3) intracerebral hematoma (ICH), 4) intraventricular hemorrhage (IVH), 5) extracerebral hematoma (ECH), 6) edema (E), 7) infarction (I). We defined ICH, IVH, ECH, E and I as new lesions. Of the 60 patients with new lesions 12 had good outcomes and 48 had poor outcomes. There were 78 patients who did not have any new lesions, 60 with good outcomes and 18 with poor outcomes. A significant correlation was found between good outcomes and the absence of new lesions, and between bad outcomes and the development of new lesions (p 2 = 44.038). We conclude that SCT can help predict the outcome with severe head injury patients and may be very important in their examination and care. (J.P.N.)

  8. Field experience with a mobile tomographic nondestructive assay system

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Betts, S.E.; Taggart, D.P.; Estep, R.J.; Nicholas, N.J.; Lucas, M.C.; Harlan, R.A.

    1995-01-01

    A mobile tomographic gamma-ray scanner (TGS) developed by Los Alamos National Laboratory was recently demonstrated at the Rocky Flats Environmental Technology Site and is currently in use at Los Alamos waste storage areas. The scanner was developed to assay radionuclides in low-level, transuranic, and mixed waste in containers ranging in size from 2 ft 3 boxes to 83-gallon overpacks. The tomographic imaging capability provides a complete correction for source distribution and matrix attenuation effects, enabling accurate assays of Pu-239 and other gamma-ray emitting isotopes. In addition, the system can reliably detect self-absorbing material such as plutonium metal shot, and can correct for bias caused by self-absorption. The system can be quickly configured to execute far-field scans, segmented gamma-ray scans, and a host of intermediate scanning protocols, enabling higher throughput (up to 20 drums per 8-hour shift). In this paper, we will report on the results of field trials of the mobile system at Rocky Flats and Los Alamos. Assay accuracy is confirmed for cases in which TGS assays can be compared with assays (e.g. with calorimetry) of individual packages within the drums. The mobile tomographic technology is expected to considerably reduce characterization costs at DOE production and environmental technology sites

  9. Computed tomographic study in children with microcephaly

    International Nuclear Information System (INIS)

    Ito, Masatoshi; Okuno, Takehiko; Mikawa, Haruki

    1989-01-01

    Computed tomographic (CT) brain scanning was performed on fifty-eight infants and children with microcephaly. CT scans were useful for detecting unsuspected brain lesions and for diagnosing underlying diseases. The head size did not correlate with the CT findings, the degree of mental retardation, or the existence of motor disturbance or epilepsy. On the other hand, the CT findings were correlated with the degree of mental retardation, and the existence of motor disturbance or epilepsy. CT scans were useful for determining the prognosis of the microcephaly. (author)

  10. Positron transaxial emission tomograph with computerized image reconstruction

    International Nuclear Information System (INIS)

    Jatteau, Michel.

    1981-01-01

    This invention concerns a positron transaxial emission tomography apparatus with computerized image reconstruction, like those used in nuclear medicine for studying the metabolism of organs, in physiological examinations and as a diagnosis aid. The operation is based on the principle of the detection of photons emitted when the positrons are annihilated by impact with an electron. The appliance is mainly composed of: (a) - a set of gamma ray detectors distributed on a polygonal arrangement around the body area to be examined, (b) - circuits for amplifying the signals delivered by the gamma ray detectors, (c) - computers essentially comprising energy integration and discrimination circuits and provided at the output of the detectors for calculating and delivering, as from the amplified signals, information on the position and energy relative to each occurrence constituted by the detections of photons, (d) - time coincidence circuits for selecting by emission of detector validation signals, only those occurrences, among the ensemble of those detected, which effectively result from the annihilation of positrons inside the area examined, (e) - a data processing system [fr

  11. Computed tomographic findings of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu

    1985-01-01

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor

  12. Computed tomographic findings of traumatic intracranial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1985-10-15

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor.

  13. Regional aspects of cerebral cysticercosis. Incidence and evaluation by computerized tomography in 1000 consecutive studies

    Energy Technology Data Exchange (ETDEWEB)

    Jozzolino, D.A. (Instituto de Tomografia Axial Computadorizada de Londrina (Brazil))

    One thousand consecutive studies of the entire brain were performed and 122 patients with tomographic diagnosis of cysticercosis were found. The high incidence of this disease is discussed and its endemic characteristics as well. Various forms and types are described, the most frequent being the presence of calcifications; other tests performed at the time of computerized tomography are mentioned.

  14. Research

    African Journals Online (AJOL)

    abp

    2014-05-10

    May 10, 2014 ... Key words: Computerized Tomographic Scan, chronic rhinosinusitis, nasal discharge, nasal .... evaluated using bone window (window width 2,000 Hounsfield units ..... paranasal sinuses and chronic sinusitis in children.

  15. Quality criteria in computerized tomography of the chest

    International Nuclear Information System (INIS)

    Doehring, W.

    1985-01-01

    The quality of thoracical computerized tomography (CT) - like any other CT examination - depends from the quality of the equipment used, from the skill of the examinor and the properties of the patient. Concerning computerized chest tomograms, rapid scan equipment should be used only and slow translation - rotation systems should not be used any more. Whereas the quality of computerized tomograms may be influenced by the patient in the scanning process only, the examining physician will decisively influence the possible informative value of the examination also in the reconstruction of the CT value matrix, in single demonstration of CT values and, possibly, in additional measurement value processing as well as in the interpretation of findings. Use of equipment should always consider the technical potential provided by the equipment to be oriented to the clinical issue, and the conditions preset by the patient. (orig.) [de

  16. Computerized tomography in atypical Pott's disease

    International Nuclear Information System (INIS)

    Cabrera, M.N.B.; Wang, E.H.M.

    1993-01-01

    Classical Pott's disease is described as a two-vertebrae disease with the destruction of the intervening invertebral disc. Computerized tomography has been used in the differential diagnosis of spine infections and neoplasms. We reviewed CT scans of patients seen at the Philippine General Hospital over a two-year period with atypical presentations of atypical tuberculous spondylitis. We used the computerized tomography findings described as characteristic of classical Pott's disease as criteria in evaluating the CT scans of patients diagnosed to have Atypical Pott's Disease. Although the number of patients prevented sensitivity and specificity studies to be done, our results strongly suggest that the same CT criteria used to diagnose Classical Pott's Disease may also be used to diagnose Pott's disease in its atypical form. (Author.). 13 refs

  17. Computerized tomography of the mandibular joints and masticatory muscles

    International Nuclear Information System (INIS)

    Huels, A.B.

    1981-01-01

    A methodology for computerized tomography of the mandibular joints was developed and applied in 80 test persons. Imaging of the mandibular joints is possible with a tomographic technique with 5 mm-overlap, full utilisation of the enlargement capacity of the imaging device, and combined use of transversal and coronary tomography. The method yields full latero-medial, cranio-caudal and anterior-posterior views of the condyle and fossa contours, free of interferences and of distortions caused by the projection. Positional diagnoses are thus possible as well as diagnoses of pathological structural changes. (orig./MG) [de

  18. Computed tomographic scanning in patients presenting with chief complaint of headache without focal neurological signs

    International Nuclear Information System (INIS)

    Halim, A.; Khalid, W.; Haq, A.U.

    2017-01-01

    To determine the frequency of positive computed tomographic (CT)scan findings in patients presenting at PNS Shifa Hospital Karachi with chief complaint of headache without focal neurological signs. Study Design: Cross sectional descriptive study. Place and Duration of Study: The study was conducted at the Radiology department, PNS Shifa Hospital Karachi from Dec 2011 to Jun 2012. Patients and Methods: This cross-sectional descriptive study included referred patients with complaint of headache of one month duration or more without focal neurological signs. No gender restriction was considered and patients of age more than 14 years were included. Patients with headache due to other known clinical disorders such as intracranial neoplasm and stroke were excluded. Patients with focal neurological signs such as hemiparesis, cerebellar signs and cranial nerve palsies were also excluded from the study. A total of 105 patients were included in the study through non probability consecutive sampling. Informed written consent was taken from the patients by explaining all the risks and benefits of the study and use of data for research and publication. Plain CT scan brain was done by trained CT technician and reporting of CT scan was done by consultant radiologist. CT scan was done on Toshiba Scanner Aquilion-64 CT Scan machine. The imaging protocol consisted of appropriately angled continuous 5mm thick axial slices for the posterior fossa and 10 mm thick slices for the rest of brain from the base of skull to the vertex. Data was collected through a specially structured proforma. Confidentiality of the patients record was maintained. Results: Majority of the patients were between 31-40 years of age i.e. 29.52 percent (n=31) and mean and SD was calculated as 34.24 +- 8.72 years, 54.29 percent (n=57) females and 45.71 percent (n=48) male patients, frequency of positive CT scan findings in patients with chief complaint of headache without focal neurological signs was recorded as

  19. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  20. Emerging tomographic methods within the petroleum industry

    International Nuclear Information System (INIS)

    Johansen, Geir Anton

    2013-01-01

    Since industrial process tomography was introduced as a concept almost two decades ago, the considerable progress within a large variety of sensing modalities has to a large extent been technology driven. Industrial tomography applications may be divided into three categories: 1) Laboratory systems, 2) Field equipment for diagnostics and mapping purposes, and 3) Permanently installed systems. Examples on emerging methods on all categories will be presented, either from R and D at the University of Bergen and/or our industrial partners. Most developments are within the first category, where tomographs are used to provide better understanding of various processes such as pipe flow, separators, mixers and reactors. Here tomographic data is most often used to provide better process knowledge, for reference measurements and validation and development of process models, and finally for development for instruments and process equipment. The requirement here may be either high spatial resolution or high temporal resolution, or combinations of these. Tomographic field measurements are applied to either to inspect processes or equipment on a regular base or at faulty or irregular operation, or to map multicomponent systems such petroleum reservoirs, their structure and the distribution gas, oil and water within them. The latter will only be briefly touched upon here. Tomographic methods are increasingly being used for process and equipment diagnostics. The requirements vary and solutions based on repetition of single measurements, such as in column scanning, to full tomographic systems where there is sufficiently space or access. The third category is tomographic instruments that are permanently installed in situ in a process. These need not provide full tomographic images and instruments with fewer views are often preferred to reduce complexity and increase the instrument reliability. (author)

  1. 1975 Memorial Award Paper. Image generation and display techniques for CT scan data. Thin transverse and reconstructed coronal and sagittal planes.

    Science.gov (United States)

    Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J

    1975-01-01

    The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.

  2. High-throughput full-automatic synchrotron-based tomographic microscopy

    International Nuclear Information System (INIS)

    Mader, Kevin; Marone, Federica; Hintermueller, Christoph; Mikuljan, Gordan; Isenegger, Andreas; Stampanoni, Marco

    2011-01-01

    At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 (micro)m to 7.4 (micro)m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 (micro)m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

  3. Tomographic anthropomorphic models. Pt. 2. Organ doses from computed tomographic examinations in paediatric radiology

    International Nuclear Information System (INIS)

    Zankl, M.; Panzer, W.; Drexler, G.

    1993-11-01

    This report provides a catalogue of organ dose conversion factors resulting from computed tomographic (CT) examinations of children. Two radiation qualities and two exposure geometries were simulated as well as the use of asymmetrical beams. The use of further beam shaping devices was not considered. The organ dose conversion factors are applicable to babies at the age of ca. 2 months and to children between 5 and 7 years but can be used for other ages as well with the appropriate adjustments. For the calculations, the patients were represented by the GSF tomographic anthropomorphic models BABY and CHILD. The radiation transport in the body was simulated using a Monte Carlo method. The doses are presented as conversion factors of mean organ doses per air kerma free in air on the axis of rotation. Mean organ dose conversion factors are given per organ and per scanned body section of 1 cm height. The mean dose to an organ resulting from a particular CT examination can be estimated by summing up the contributions to the organ dose from all relevant sections. To facilitate the selection of the appropriate sections, a table is given which relates the tomographic models' coordinates to certain anatomical landmarks in the human body. (orig.)

  4. Computerized axil tomographic scanning in tumors of the adrenal glands

    International Nuclear Information System (INIS)

    Albertotti, C.; Figueiredo, M.A.; Clemente Filho, A.S.; Secaf, F.

    1980-01-01

    Computed tomography was used for diagnosing primary or recurrent adrenal gland tumors, being positive in all nine cases and later confirmed at surgery. The tumors are adenocarcinoma (6 cases); pheochromocytoma (2); aldostenoma (1) an cyst(u). Comparison of selective arteriography, ultrasonography, scintigraphy and computed tomography has shown the later to be most accurate. (Author) [pt

  5. Sensitivity study of poisson corruption in tomographic measurements for air-water flows

    International Nuclear Information System (INIS)

    Munshi, P.; Vaidya, M.S.

    1993-01-01

    An application of computerized tomography (CT) for measuring void fraction profiles in two-phase air-water flows was reported earlier. Those attempts involved some special radial methods for tomographic reconstruction and the popular convolution backprojection (CBP) method. The CBP method is capable of reconstructing void profiles for nonsymmetric flows also. In this paper, we investigate the effect of corrupted CT data for gamma-ray sources and aCBP algorithm. The corruption in such a case is due to the statistical (Poisson) nature of the source

  6. Evaluation of paranasal sinus mucosa in coal worker's pneumoconiosis - A computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, H.; Altin, R.; Mahmutyazicioglu, K.; Kart, L.; Uzun, L.; Savranlar, A.; Davcanci, H.; Gundogdu, S. [Zonguldak Karaelmas University, Zonguldak (Turkey). School of Medicine

    2004-09-01

    Objective: To evaluate by computed tomographic scanning the paranasal mucosal changes of coal workers with and without pneumoconiosis. Methods: Examination of images and scores from paranasal computed tomographic scans. The study participants were 26 coal workers with pneumoconiosis, 29 coal workers without pneumoconiosis, and 20 controls. All were men. The extent and patterns of inflamatory paranasal sinus disease were evaluated on computed, tomographic scans by 2 radiologists using the terminology and definitions of Newman and associates. Results: Interobserver agreement for the presence of abnormalities was from good to excellent (K, 0.63-0.89). The mucosal scores of individuals and groups were higher for coal workers than for control subjects. Both scores were significantly higher in the pneumoconiosis group than in the 2 other groups. Conclusions: This study shows that paranasal sinuses were affected more severely in coal workers than in control subjects. In coal workers with pneumoconiosis, the affection was most severe. The relationship between coal dust exposure and paranasal mucosal changes needs further study.

  7. Cranial Computerized Tomography In The Evaluation Of Stroke ...

    African Journals Online (AJOL)

    206 patients clinically diagnosed as stroke / cerebrovascular accidents (CVA) were investigated using computerized tomography (CT) scan. 19 patients (9%) had normal scan. While 20(9.7%) had other lesions including atrophy and tumours. Of the 167 (18. %) patients proven to have suffered a cerebro- vascular accident ...

  8. Three dimensional reconstruction of tomographic images of the retina

    International Nuclear Information System (INIS)

    Glittenberg, C.; Zeiler, F.; Falkner, C.; Binder, S.; Povazay, B.; Hermann, B.; Drexler, W.

    2007-01-01

    The development of a new display system for the three-dimensional visualization of tomographic images in ophthalmology. Specifically, a system that can use stacks of B-mode scans from an ultrahigh resolution optical tomography examination to vividly display retinal specimens as three-dimensional objects. Several subroutines were programmed in the rendering and raytracing program Cinema 4D XL 9.102 Studio Bundle (Maxon Computer Inc., Friedrichsburg, Germany), which could process stacks of tomographic scans into three-dimensional objects. Ultrahigh resolution optical coherence tomography examinations were performed on patients with various retinal pathologies and post processed with the subroutines that had been designed. All ultrahigh resolution optical coherence tomographies were performed with a titanium: sapphire based ultra broad bandwidth (160 nm) femtosecond laser system (INTEGRAL, Femtolasers Productions GmbH. Vienna Austria) with an axial resolution of 3 μm. A new three dimensional display system for tomographic images in ophthalmology was developed, which allows a highly vivid display of physiological and pathological structures of the retina. The system also distinguishes itself through its high interactivity and adaptability. This new display system allows the visualization of physiological and pathological structures of the retina in a new way, which will give us new insight into their morphology and development. (author) [de

  9. Construction of tomographic head model using sectioned photographic images of cadaver

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Lee, Jai Ki; Park, Jin Seo; Chung, Min Suk

    2004-01-01

    Tomographic models are currently the most complete, developed and realistic models of the human anatomy. They have been used to estimate organ doses for diagnostic radiation examination and radiotherapy treatment planning, and radiation protection. The quality of original anatomic images is a key factor to build a quality tomographic model. Computed tomography (CT) and magnetic resonance imaging (MRI) scan, from which most of current tomographic models are constructed, have their inherent shortcomings. In this study, a tomographic model of Korean adult male head was constructed by using serially sectioned photographs of cadaver. The cadaver was embedded, frozen, serially sectioned and photographed by high resolution digital camera at 0.2 mm interval. The contours of organs and tissues in photographs were segmented by several trained anatomists. The 120 segmented images of head at 2mm interval were converted into binary files and ported into Monte Carlo code to perform an example calculation of organ dose. Whole body tomographic model will be constructed by using the procedure developed in this study

  10. Evaluation of supra- and infratentorial brain atrophy by computerized tomography in spinocerebellar degeneration

    International Nuclear Information System (INIS)

    Yamamoto, Hiroko; Asano, Yasuhiko; Watanabe, Takatoshi; Hirao, Yoshitaka; Mizuno, Yasushi; Sobue, Itsuro

    1986-01-01

    Measurement of various parameters of supra- and infratentorial brain atrophy in computerized tomographs of 142 cases of spinocerebellar degeneration (SCD) and 100 age and sex matched controls was carried out in order to investigate whether these parameters would correspond to the subtypes of this disease and differing grades of various clinical manifestations. One supra- and all infratentorial parameters of SCD showed statistically significant atrophy with a risk of P < 0.005. Among the subtypes, OPCA had a more severely atrophied pons than LCCA (P < 0.005), Menzel (P < 0.05) and SSP (P < 0.01). There was a correlation between the distribution of symptoms like gait, speech, ataxia of extremities and ocular movement disorders, and distribution and degree of infratentorial atrophy with statistical significance (P < 0.05 ∼ P < 0.005). The degree of atrophy of the pons and the width of the IV ventricle were directly proportional to the duration of the illness in cases of less than 10 years, but not to those of over 10 years. Follow-up CT scan was done for 24 patients, 12 within 3 years, 12 after the lapse of 3 years. The latter group showed statistically significant atrophy between the 1st and 2nd scans in several parameters, but there was no significance between those of the former group. (author)

  11. Evaluation of supra- and infratentorial brain atrophy by computerized tomography in spinocerebellar degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiroko; Asano, Yasuhiko; Watanabe, Takatoshi; Hirao, Yoshitaka; Mizuno, Yasushi; Sobue, Itsuro

    1986-08-01

    Measurement of various parameters of supra- and infratentorial brain atrophy in computerized tomographs of 142 cases of spinocerebellar degeneration (SCD) and 100 age and sex matched controls was carried out in order to investigate whether these parameters would correspond to the subtypes of this disease and differing grades of various clinical manifestations. One supra- and all infratentorial parameters of SCD showed statistically significant atrophy with a risk of P < 0.005. Among the subtypes, OPCA had a more severely atrophied pons than LCCA (P < 0.005), Menzel (P < 0.05) and SSP (P < 0.01). There was a correlation between the distribution of symptoms like gait, speech, ataxia of extremities and ocular movement disorders, and distribution and degree of infratentorial atrophy with statistical significance (P < 0.05 -- P < 0.005). The degree of atrophy of the pons and the width of the IV ventricle were directly proportional to the duration of the illness in cases of less than 10 years, but not to those of over 10 years. Follow-up CT scan was done for 24 patients, 12 within 3 years, 12 after the lapse of 3 years. The latter group showed statistically significant atrophy between the 1st and 2nd scans in several parameters, but there was no significance between those of the former group.

  12. Pedicle measurement of the thoracolumbar spine: a cadaveric, radiographic, and CT scan study in Filipinos

    International Nuclear Information System (INIS)

    Molano, A.M.V.; Sison, A.B.; Fong, H.C.; Lim, N.T.; Sabile, K.

    1994-01-01

    With the popular usage of spinal pedicular screw fixation, it is essential to have a knowledge of the morphometry of the pedicles of the spine of particular populations. This study compared the direct pedicle measurements of ten cadavers in an institution, with their respective radiographic and computerized tomographic (CT) scan values, and also compared the effective pedicle diameter (EPD) with the conventional outer pedicle diameter (OPD) measurements. A compilation of pedicle values was also made in X-ray and CT scan plates of a Filipino population. A statistical analysis made on the 2,760 pedicle measurements taken from cadaveric T6-L5 vertebrae showed that direct measurements were significantly different from X-ray and CT scan values. The mean values of the EPD differed from those of the OPD, but not statistically significant. Comparison with previous foreign studies revealed significant differences in these pedicle dimensions. Pedicle measurements in a living Filipino population were found to be significantly different statistically between sexes. Accurate measurement of the pedicle diameters and lengths are indeed critical for the success of a spinal stabilization procedure using pedicular screws. (author). 8 refs.; 5 figs.; 1 tab

  13. Novel edge treatment method for improving the transmission reconstruction quality in Tomographic Gamma Scanning.

    Science.gov (United States)

    Han, Miaomiao; Guo, Zhirong; Liu, Haifeng; Li, Qinghua

    2018-05-01

    Tomographic Gamma Scanning (TGS) is a method used for the nondestructive assay of radioactive wastes. In TGS, the actual irregular edge voxels are regarded as regular cubic voxels in the traditional treatment method. In this study, in order to improve the performance of TGS, a novel edge treatment method is proposed that considers the actual shapes of these voxels. The two different edge voxel treatment methods were compared by computing the pixel-level relative errors and normalized mean square errors (NMSEs) between the reconstructed transmission images and the ideal images. Both methods were coupled with two different interative algorithms comprising Algebraic Reconstruction Technique (ART) with a non-negativity constraint and Maximum Likelihood Expectation Maximization (MLEM). The results demonstrated that the traditional method for edge voxel treatment can introduce significant error and that the real irregular edge voxel treatment method can improve the performance of TGS by obtaining better transmission reconstruction images. With the real irregular edge voxel treatment method, MLEM algorithm and ART algorithm can be comparable when assaying homogenous matrices, but MLEM algorithm is superior to ART algorithm when assaying heterogeneous matrices. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Neurosurgical operating computerized tomographic scanner system. The CT scanner in the operating theater

    Energy Technology Data Exchange (ETDEWEB)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi

    1988-12-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place.

  15. Dose profile study on computerized tomography scanning of skull with simulator object; Estudo do perfil de dose em varreduras de TC de cranio com objeto simulador

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, A.P., E-mail: aprata@des.cefetmg.b [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar; Alonso, Thessa C.; Silva, Teogenes A. da, E-mail: alonso@cdtn.b, E-mail: silvata@@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-10-26

    This work presents a comparison among the dose profiles in scanning of computerized tomography of a simulator object of PMMA in its periphery region. To obtain the deposited dose at the PMMA thermoluminescent dosemeters were used positioned at the interior of PMMA simulated object longitudinal to periphery and at the center of cylinder (positions denominated North, South, East, West and Center). Eight scanning were performed of simulator object using the routine protocol for skull in eight different services of radiodiagnostic by TC

  16. Tay-Sachs disease with conspicuous cranial computerized tomographic appearances

    International Nuclear Information System (INIS)

    Watanabe, Kishichiro; Mukawa, Akio; Muto, Kazuhiko; Nishikawa, Jiro; Takahashi, Shigeko.

    1985-01-01

    An autopsy case of a 3-year-old female infant with Tay-Sachs disease was presented. A cherry red spot in the fundus and a deficiency of N-acetyl-β-hexosaminidase A in the white blood cells were revealed soon after admission at the age of one year. Her parents and sister were found to be healthy carriers. The patient showed a typical clinical course with marked cranial swelling. In addition to the marked ballooning of neurons on light microscope, membranous cytoplasmic body (MCB) on electron microscope and abnormal accumulation of GM 2 ganglioside in the cerebral cortex by thin layer chromatography were confirmed in the autopsy specimens. In the late stage of her clinical course, the cranial computerized tomography (CT) demonstrated symmetric and deep-wavy hyperdense cerebral cortical zones, diffuse hypodensity and diminished volume of cerebral white matter, mild to moderate ventricular dilatation, and a small cerebellum and brainstem. These conspicuous appearances of the cranial CT seem to be characteristic of Tay-Sachs disease in the late stage, and they are derived from abnormal accumulation of GM 2 ganglioside in the cerebral cortex, and diffuse intense demyelination (dysmyelinating demyelination) of the cerebral white matter. (author)

  17. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The principal problem in trans-axial tomographic radioisotope scanning is the length of time required to obtain meaningful data. Patient movement and radioisotope migration during the scanning period can cause distortion of the image. The object of this invention is to reduce the scanning time without degrading the images obtained. A system is described in which a scintillation camera detector is moved to an orbit about the cranial-caudal axis relative to the patient. A collimator is used in which lead septa are arranged so as to admit gamma rays travelling perpendicular to this axis with high spatial resolution and those travelling in the direction of the axis with low spatial resolution, thus increasing the rate of acceptance of radioactive events to contribute to the positional information obtainable without sacrificing spatial resolution. (author)

  18. Regional cerebral blood flow during rest and skilled hand movements by xenon-133 inhalation and emission computerized tomography

    DEFF Research Database (Denmark)

    Lauritzen, M; Henriksen, L; Lassen, N A

    1981-01-01

    Regional cerebral blood flow (CBF) was studied in 16 normal adult volunteers during rest and in 10 the study was repeated during skilled hand movements. A fast-rotating ("dynamic"), single-photon emission computerized tomograph (ECT) with four detector heads was used. Xenon-133 was inhaled over a 1...... motor area on both sides by 34 +/- 15% (p less than 0.025)....

  19. Evaluation of quality of tomographs of Rio de Janeiro state, Brazil; Avaliacao da qualidade dos tomografos do estado do Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Travassos, P.C.B.; Belem, V.R.; Magalhaes, L.A.; Almeida, C.E.A. de, E-mail: luisalexandregm@hotmail.com [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas

    2014-07-01

    Computerized tomographs used in 56 institutions in the state of Rio de Janeiro were evaluated. Criteria of image quality and dosimetry were submitted. The results showed that some not performed optimize their protocols examinations or perform wrongly, which results in an increase in the dose received by patients, and an image in compromised quality. (author)

  20. 2D histomorphometric quantification from 3D computerized tomography

    International Nuclear Information System (INIS)

    Lima, Inaya; Oliveira, Luis Fernando de; Lopes, Ricardo T.; Jesus, Edgar Francisco O. de; Alves, Jose Marcos

    2002-01-01

    In the present article, preliminary results are presented showing the application of the tridimensional computerized microtomographic technique (3D-μCT) to bone tissue characterization, through histomorphometric quantification which are based on stereologic concepts. Two samples of human bone were correctly prepared to be submitted to the tomographic system. The system used to realize that process were a radiographic system with a microfocus X-ray tube. Through these three processes, acquisition, reconstruction and quantification, it was possible to get the good results and coherent to the literature data. From this point, it is intended to compare these results with the information due the conventional method, that is, conventional histomorphometry. (author)

  1. Computerized tomographic visualization of niveau by turning the head in a case of pituitary apoplexy

    International Nuclear Information System (INIS)

    Sasajima, Toshio; Mineura, Katsuyoshi; Kowada, Masayoshi; Sasaki, Junko; Sasajima, Hiroyasu; Sakamoto, Tetsuya

    1987-01-01

    A case of pituitary apoplexy is presented in which a free niveau formation, a pathognomonic sign of this entity, was proved by means of computerized tomography (CT) by turning the head. A 48-year-old female had developed a sudden, excruciating, retroorbital headache, vomiting, and visual disturbance twice prior to admission. The visual acuity was 0.1 in the right eye and 0.6 in the left eye. The optic fundi were normal. There was a right temporal field loss and a left upper temporal quadrantanopsia. A plain skull film disclosed ballooning and a double floor of the turcic sella. A CT scan of the head, performed by means of a GE CT/T 8800 Scanner, showed an intrasellar low-density mass with a slightly enhanced rim. We were not convinced of the presence of a high-density area, though there seemed to be one adjacent to the posterior clinoid process and the turcic floor, because of the partial volume effect and the artifact related to the neighboring bones. Another high-resolution CT scan on the ensuing day, as the head was turned and then kept still at about 45 degrees to the right, while the patient was supine, for ten minutes, made it possible to visualize a free fluid level, comparable to a fluid-blood-density level. A transsphenoidal pituitary exploration identified blood fluid collection in the encapsulated tumor, a finding which was histologically consistent with the sinusoidal type of chromophobe adenoma. There was some microscopic evidence of necrosis and hemosiderin laden cells. The postoperative course was uneventful; visual acuity improved without delay, and the temporal field defect became significantly smaller. Two weeks later, visual acuity had recovered to 1.2 uncorrected in each eye. CT and the pertinent position of the head might be quite helpful for the visualization and confirmation of a subtle free fluid level in cases of pituitary apoplexy. (author)

  2. Computerized Tomographic Study on the Anatomic Variation of the Paranasal Sinus

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Kyung; Lim, Sug Young; Koh, Kwang Joon [Dept. of Oral and Maxillofacial Radiology and Institute of Oral Bio Science, College of Dentistry, Chonbuk National University, Chonju (Korea, Republic of); Park, Mi Ju [Dept. of Prosthodontics, School of Denstistry, Chonbuk National Universty, Chonju (Korea, Republic of)

    1999-08-15

    To evaluate the anatomic variations of the paranasal sinuses on computed tomographs. The author examined the CT images of the paranasal sinuses retrospectively in 500 patients who visited Chonbuk National University Hospital between January 1996 and December 1997. The highest incidence of anatomic variation of the paranasal sinuses in bilateral structures was agger nasi cell (73.2%), followed by concha bullosa (31.1%), Onodi cell (24.0%), Haller cell (19.8%), maxillary sinus septum (13.0%), paradoxical middle turbinate (2.5%), pneumatized uncinate process (2.0%), and bent uncinate process. The highest incidence of anatomic variation in midline structures was nasal septum deviation(53.2%), followed by nasal septumaerated (29.4%), bulla galli (24.7%) asymmetric intersphenoid septum (22.3%), and nasal septum spur (13.8%). The correlation between anatomic variation and paranasal sinusitis was not found. The results of this study will aid in the diagnosis and treatment of paranasal sinus diseases, especially in the treatment planning before functional endoscopic surgery.

  3. Computerized Tomographic Study on the Anatomic Variation of the Paranasal Sinus

    International Nuclear Information System (INIS)

    Choi, Sun Kyung; Lim, Sug Young; Koh, Kwang Joon; Park, Mi Ju

    1999-01-01

    To evaluate the anatomic variations of the paranasal sinuses on computed tomographs. The author examined the CT images of the paranasal sinuses retrospectively in 500 patients who visited Chonbuk National University Hospital between January 1996 and December 1997. The highest incidence of anatomic variation of the paranasal sinuses in bilateral structures was agger nasi cell (73.2%), followed by concha bullosa (31.1%), Onodi cell (24.0%), Haller cell (19.8%), maxillary sinus septum (13.0%), paradoxical middle turbinate (2.5%), pneumatized uncinate process (2.0%), and bent uncinate process. The highest incidence of anatomic variation in midline structures was nasal septum deviation(53.2%), followed by nasal septumaerated (29.4%), bulla galli (24.7%) asymmetric intersphenoid septum (22.3%), and nasal septum spur (13.8%). The correlation between anatomic variation and paranasal sinusitis was not found. The results of this study will aid in the diagnosis and treatment of paranasal sinus diseases, especially in the treatment planning before functional endoscopic surgery.

  4. Congenital syphylitic hepatitis: a case report with multiple imaging modalities (syphilitic hepatitis)

    Energy Technology Data Exchange (ETDEWEB)

    Heyman, S; Rosenberg, H K; Mandell, G A; Golden, D A

    1983-11-14

    A case of syphilitic hepatitis is described with no evidence of mass effect on the ultrasonic and computerized tomographic study, but with discrete areas of decreased uptake on liver scan suggestive of space-occupying lesion. This is the second instance in the literature of the incongruence of the liver scan and the other imaging modalities in syphilitic hepatitis.

  5. Congenital syphylitic hepatitis: a case report with multiple imaging modalities (syphilitic hepatitis)

    International Nuclear Information System (INIS)

    Heyman, S.; Rosenberg, H.K.; Mandell, G.A.; Golden, D.A.

    1983-01-01

    A case of syphilitic hepatitis is described with no evidence of mass effect on the ultrasonic and computerized tomographic study, but discrete areas of decreased uptake on liver scan suggestive of space-occupying lesion. This is the second instance in the literature of the incongruence of the liver scan and the other imaging modalities in syphilitic hepatitis. (orig.)

  6. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Visser, M de; Verbeeten, Jr, B J

    1988-06-04

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs.

  7. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    International Nuclear Information System (INIS)

    Visser, M. de; Verbeeten, B.J. Jr.

    1988-01-01

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs

  8. Mesooptical microscope as a tomographical device

    International Nuclear Information System (INIS)

    Soroko, L.M.

    1989-01-01

    It is shown that there are at least four regions which are common for the mesooptical microscopes, on the one hand, and for the reconstructed tomography, on the other hand. The following characteristics of the mesooptical microscope show the tomographical properties: the structure of the output data concerning the orientation and the position in space of the straight-line objects going at small angles with the perpendicular to the given tomographic plane, the behaviour of the two-dimensional fourier-transform of the straight-line object in the course of the rotation of this object with respect to the specified axis in space, the scanning algorithm of the nuclear emulsion volume by the fence-like illuminated region in the mesooptical microscope for searching for particle tracks going parallel to the optical axis of the microscope, and, finally, the fact that the mesooptical images of the straight-line particle tracks with a common vertex in the nuclear emulsion lie on the sinogram. 12 refs.; 16 figs

  9. Quantitation of size of myocardial infarctions by computerized transmission tomography. Comparison with hot-spot and cold-spot radionuclide scans

    International Nuclear Information System (INIS)

    Gerber, K.H.; Higgins, C.B.

    1983-01-01

    The current study evaluated the ability to quantitate the volume of myocardial infarctions when they are outlined by intravenously administered contrast media in the myocardial perfusion phase and in the phase of delayed contrast enhancement of the infarct. Quantitation by contrast media was assessed from computerized transmission tomography (CTT) scans of the ex situ heart and compared with quantitation by technetium-99m (/sup 99m/Tc)pyrophosphate (/sup 99m/Tc PYP) and thallium-201 (201Tl) scans of the same ex situ hearts. True volume was defined by histochemical morphometry. CTT during the contrast perfusion phase uniformly underestimated infarct size but had a good correlation with true volume. CTT during enhancement phase correlated closely with true volume (r . 0.98) and most precisely measured true size (y . 1.06 X 0.23). The /sup 99m/Tc PYP scan overestimated infarct volume (predictive overestimation of 6 to 199%) but had a good correlation with true volume. 201Tl underestimated infarct volume but correlated well with true volume. Thus, quantitation of infarct volume from CTT scans performed during either the perfusion or infarct enhancement phase after intravenous contrast media provides a good estimate of true infarct volume. Delineation of the infarct by contrast media in the ex situ heart is more precise during the phase of delayed enhancement of the infarct

  10. An intragastric trichobezoar: computerised tomographic appearance.

    Directory of Open Access Journals (Sweden)

    Morris B

    2000-04-01

    Full Text Available A 26-year-old lady presented with a history of abdominal pain and distension since two months. The ultrasound examination showed an epigastric mass, which was delineated as a filling defect in the stomach on barium studies. The computerised tomographic scan showed a gastric mass with pockets of air in it, without post-contrast enhancement. This case highlights the characteristic appearance on computerised tomography of a bezoar within the stomach, a feature that is not commonly described in medical literature.

  11. Development of the Shimadzu computed tomographic scanner SCT-200N

    International Nuclear Information System (INIS)

    Ishihara, Hiroshi; Yamaoka, Nobuyuki; Saito, Masahiro

    1982-01-01

    The Shimadzu Computed Tomographic Scanner SCT-200N has been developed as an ideal CT scanner for diagnosing the head and spine. Due to the large aperture, moderate scan time and the Zoom Scan Mode, any part of the body can be scanned. High quality image can be obtained by adopting the precisely stabilized X-ray unit and densely packed array of 64-detectors. As for its operation, capability of computed radiography (CR) prior to patient positioning and real time reconstruction ensure efficient patient through-put. Details of the SCT-200N are described in this paper. (author)

  12. Heidelberg Retina Tomograph for the Detection of Glaucoma

    Directory of Open Access Journals (Sweden)

    Barbara Cvenkel

    2012-06-01

    Full Text Available Heidelberg Retina Tomograph (HRT is a confocal scanning laser ophthalmoscope which acquires and analyzes 3-dimensional images of the optic nerve head. The latest instrument HRT3 includes software with larger ethinic-specific normative database. This review summarizes relevant published literature on HRT in diagnosing glaucoma, detecting glaucoma progression, the diagnostic accuracy of HRT among other imaging devices and its role in clinical practice.

  13. Evaluation of Biomaterials Using Micro-Computerized Tomography

    International Nuclear Information System (INIS)

    Torris, A. T. Arun; Columbus, K. C. Soumya; Saaj, U. S.; Krishnan, Kalliyana V.; Nair, Manitha B.

    2008-01-01

    Micro-computed tomography or Micro-CT is a high resolution, non-invasive, x-ray scanning technique that allows precise three-dimensional imaging and quantification of micro-architectural and structural parameters of objects. Tomographic reconstruction is based on a cone-beam convolution-back-projection algorithm. Micro-architectural and structural parameters such as porosity, surface area to volume ratio, interconnectivity, pore size, wall thickness, anisotropy and cross-section area of biomaterials and bio-specimens such as trabecular bone, polymer scaffold, bio-ceramics and dental restorative were evaluated through imaging and computer aided manipulation of the object scan data sets.

  14. Clinical significance of bone scintigraphy and computerized tomography (CT scan) in the evaluation of renal osteodystrophy in haemodialysed and non-haemodialysed patients

    International Nuclear Information System (INIS)

    Yatsuboshi, Motohiko

    1978-01-01

    For the evaluation of renal osteodystophy in both haemodialysed and non-haemodialysed patients, bone scintigraphy and computerized tomography (CT) scan were performed. Twenty-six patients with chronic renal failure were objectives of the study. For the control study of CT scan, patients with brain tumor without renal disease were selected. Bone scan was performed approximately 3 hours after sup(99m) Tc-EHDP (ethane-1-hydroxy-1, 1-diphosphonate) administration. The numericals which were printed out from CT scanner were analyzed in the area of frontal bone. The number of positive group was 9 and that of negative was 17. Positive group in non-haemodialysed patients showed lower serum calcium level and creatinine clearance and higher serum levels of inorganic phosphate and BUN compared with those of negative group. Positive scan group showed longer duration of dialysis and higher serum levels of parathyroid hormone and alkaline phosphatase than those of negative group. Frequency of abnormal findings detected by bone scan was higher than that elicited by roentgenographic examination. CT number of positive scan group was lower than that of negative group or control group. CT number in patients with subperiosteal resorption of phalanx and abnormal findings of calvarium was lower than that of patients without such roentgenographic abnormalities. These findings indicate that bone scan is useful in detecting bone changes of secondary hyperparathyroidism in chronic renal failure. CT scan could also help to estimate the decrease of bone density of calvarium in chronic renal failure. (author)

  15. Computed tomographic findings of cerebral arterial ectasia

    International Nuclear Information System (INIS)

    Choi, Woo Suk; Ko, Young Ho; Lim, Jae Hoon

    1987-01-01

    The computed tomographic findings of cerebral arterial ectasia in 8 patients, of which 5 cases were angiographically documented, are reported. The ecstatic arteries, located predominantly in the suprasellar and interpeduncular cisterns, appeared as serpignous, tubular structures on the unenhanced scan. The enhanced CT scan demonstrated dense, sharply defined, homogeneous intraluminal enhancement. Until recently, the diagnosis of cerebral arterial ectasia was usually established by angiography. With introduction of CT it has become possible to noninvasively identify and characterize this vascular disorder and its associated intracranial complications. The vertebrobasilar dolichoectasia may be diagnosed by CT as an extra-axial lesion in the cerebellopontine angle. It enhances in a tubular fashion after intravenous injection of contrast.

  16. Preoperative localization of parathyroid tumor by computerized tomography

    International Nuclear Information System (INIS)

    Kan, Seiji; Hiraishi, Koji; Nakamura, Shoichiro; Yamamoto, Schuzo; Odachi, Motoaki; Yamashita, Toshiyuki.

    1984-01-01

    Five patients of primary hyperparathyroidism with urolithiasis underwent CT-scanning for the preoperative localization of parathyroid tumor. The tumor was identified in all patients but one, who had a multiple adenomatous goiter. In this case, postoperative observation of the CT-scan revealed the parathyroid tumor. It appears that if the size of the parathyroid tumor is about 1cm in diameter, there is a high possibility of preoperative localization by computerized tomography. (author)

  17. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    Science.gov (United States)

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant

  18. The Pattern of Significant Lesions Found in Computerized ...

    African Journals Online (AJOL)

    Introduction: Seizures are common reasons for neurologic consultations and investigations. In the absence of magnetic resonance imaging, computerized tomography scanning of the brain is a reliable and cheaper alternative. Little is known about the pattern of brain lesions in patients with recurrent seizures in Nigeria.

  19. [Evaluation of the risk of mediastinal or retroperitoneal injuries caused by dorso-lumbar pedicle screws].

    Science.gov (United States)

    Hernigou, P; Germany, W

    1998-09-01

    Within an anatomical and a clinical study, the authors employed computerized tomographic scans to evaluate the risks of anterior surrounding tissues injuries during screw insertion. CT scans of 20 patients suffering from cardiac disease were reviewed retrospectively. Scans through the thoracic and lumbar spine were obtained using 6 mm slice thickness. These examinations were performed with intravenous contrast medium. Measurements of vessel diameters and distance of the soft tissues situated directly anterior to the spine were done. A retrospective study of 61 pedicle screws implanted for spine fractures evaluated the penetration of the anterior vertebral cordex with X rays and CT scans. Computerized tomographic scans of the thoracic and lumbar spine of the 20 patients in the control group confirmed proximity of the posterior mediastinal structures to the anterior vertebral cortex. Many structures of the posterior mediastinum were within five millimeters of the anterior vertebral cortex and thus were at risk: aorta, azygos vein, vena cava, parietal pleura and lungs. The theoretical risk of unrecognized screw penetrations evaluated on geometric shape of the anterior vertebral body is as high as 21 per cent when screw position is only seen with an antero posterior and a lateral X Ray. In the other group, computerized tomographic scans showed that 30 per cent of the implanted screws were outside the boundaries of the anterior thoracic spine. Two orthogonal incidences do not enable determination of whether the extremity of the screw is slightly outside the anterior cortex of the vertebral body. However the geometric shape of the anterior vertebral body enables peroperative definition of a safety zone on two orthogonal incidences. Even if a breach of a few millimeters of the anterior cortical boundaries of the vertebral body may not initially damage the adjacent soft-tissue structures, chronic irritation may result in late damages of these structures. The use of

  20. Renal Angiomyolipoma Presenting as Acute Abdominal Emergency ...

    African Journals Online (AJOL)

    A 47-year-old woman presented as an acute abdominal emergency with rapid progression to shock following spontaneous rupture of a left renal angiomyolipoma. The diagnosis was missed clinically and on computerized tomographic scan. At different stages of management based on her pattern of symptoms, signs and ...

  1. WAJM 29(3).pmd

    African Journals Online (AJOL)

    user1

    seizures occurring after four weeks following brain injury. ... of and predisposing type of head injury to developing post ... functions in the brain have been put .... The computerized tomographic scan showing a right-sided acute-on-chronic subdural hematoma with ipsilateral ventricular effacement and midline shift to the left.

  2. ULTRASOUND AND COMPUTED TOMOGRAPHIC DIAGNOSIS OF OPTIC NERVE TUMORS

    Directory of Open Access Journals (Sweden)

    S. V. Saakyan

    2012-01-01

    Full Text Available A comprehensive examination was made in 93 patients, including 18 children, with tumors of the optic nerve (ON. Duplex ultrasound scanning was performed in 39 patients, of them there were 11 patients with ON gliomas and 28 with ON meningiomas. The specific computed tomographic and echographic signs of ON glioma and meningiomas were detected. The studies have shown that duplex ultrasound scanning and structural computed tomography of orbital sockets are highly informative complementary imaging procedures for ON tumors, which permits one to make their correct diagnosis, to specify surgical volume, and to plan adequate treatment.

  3. Tomographic retrieval of cloud liquid water fields from a single scanning microwave radiometer aboard a moving platform – Part 1: Field trial results from the Wakasa Bay experiment

    Directory of Open Access Journals (Sweden)

    D. Huang

    2010-07-01

    Full Text Available Tomographic methods offer great potential for retrieving three-dimensional spatial distributions of cloud liquid water from radiometric observations by passive microwave sensors. Fixed tomographic systems require multiple radiometers, while mobile systems can use just a single radiometer. Part 1 (this paper examines the results from a limited cloud tomography trial with a single-radiometer airborne system carried out as part of the 2003 AMSR-E validation campaign over Wakasa Bay of the Sea of Japan. During this trial, the Polarimetric Scanning Radiometer (PSR and Microwave Imaging Radiometer (MIR aboard the NASA P-3 research aircraft provided a useful dataset for testing the cloud tomography method over a system of low-level clouds. We do tomographic retrievals with a constrained inversion algorithm using three configurations: PSR, MIR, and combined PSR and MIR data. The liquid water paths from the PSR retrieval are consistent with those from the MIR retrieval. The retrieved cloud field based on the combined data appears to be physically plausible and consistent with the cloud image obtained by a cloud radar. We find that some vertically-uniform clouds appear at high altitudes in the retrieved field where the radar shows clear sky. This is likely due to the sub-optimal data collection strategy. This sets the stage for Part 2 of this study that aims to define optimal data collection strategies using observation system simulation experiments.

  4. Emission computerized-tomography and determination of local brain function

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Alavi, A.; Reivich, M.; Edwards, R.Q.; Fenton, C.A.; Zimmerman, R.A.

    1975-01-01

    Methods for the three dimensional reconstruction of /sup 99m/Tc brain scans are described. The diagnostic advantages of computerized tomography in the localization of brain tumors and in measurements of local cerebral blood flow are discussed. (U.S.)

  5. Study of the human encephalon morphology by computerized axial tomography in neurological diseases

    International Nuclear Information System (INIS)

    Loynaz Fernandez, Clara Silvia; Milan Companioni, Daile; Gomez Padron, Ivo; Alvarez Leon, Oladys; Espinosa Quiros, Desiderio

    2001-01-01

    Since the middle of the last century, the study of the human encephalon morphology has been of great interest for the researchers. With the introduction of the computerized axial tomography in 1974, it was possible to expand the knowledge about this area and at the same time provide information on the structural lesions that are pathologies of great psychosocial repercussion like epilepsy and Parkinsonism. This paper used 90 tomographic studies on people aged 20-80 years. A series of linear measurements were made and statistically processed. The results showed variations in linear measurements among control, epileptic and Parkinsonian subjects

  6. Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Lopes, Agnaldo Jose; Capone, Domenico; Mogami, Roberto; Jansen, Jose Manoel .E mail: phel.lop@uol.com.br; Cunha, Daniel Leme da; Melo, Pedro Lopes de

    2007-01-01

    Objective: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF). Methods: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography findings were quantified: total interstitial disease (TID), reticular abnormality/honeycombing, and ground-glass opacity (GGO). The functional variables were measured by spirometry, forced oscillation technique (FOT), helium dilution method, as well as the single-breath method of measuring diffusion capacity of the lung for carbon monoxide (DLCO). Results: Of the 30 patients studied, 18 were female, and 12 were male, with a mean age of 70.9 years. We found that TID and reticular abnormality and honeycombing correlated significantly (negative correlations) with the measurements of forced vital capacity (FVC), total lung capacity (TLC), DLCO, and dynamic respiratory compliance were found, as well as that GGO correlated significantly (and positively) with residual volume/TLC. The ratio of forced expiratory flow between 25 and 75% of FVC to FVC (FEF25-75%/FVC) correlated positively with TID, reticular abnormality/honeycombing, and GGO. Conclusion: In IPF patients, the measurements of volume, diffusion, and dynamic compliance are the physiological variables which best reflect the extent of the interstitial disease on HRCT scans. (author)

  7. Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Agnaldo Jose; Capone, Domenico; Mogami, Roberto; Jansen, Jose Manoel [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). School of Medical Sciences].E mail: phel.lop@uol.com.br; Cunha, Daniel Leme da [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Pedro Ernesto University Hospital. Dept. of Radiology and Diagnostic Imaging; Melo, Pedro Lopes de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. of Biology

    2007-11-15

    Objective: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF). Methods: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography findings were quantified: total interstitial disease (TID), reticular abnormality/honeycombing, and ground-glass opacity (GGO). The functional variables were measured by spirometry, forced oscillation technique (FOT), helium dilution method, as well as the single-breath method of measuring diffusion capacity of the lung for carbon monoxide (DLCO). Results: Of the 30 patients studied, 18 were female, and 12 were male, with a mean age of 70.9 years. We found that TID and reticular abnormality and honeycombing correlated significantly (negative correlations) with the measurements of forced vital capacity (FVC), total lung capacity (TLC), DLCO, and dynamic respiratory compliance were found, as well as that GGO correlated significantly (and positively) with residual volume/TLC. The ratio of forced expiratory flow between 25 and 75% of FVC to FVC (FEF25-75%/FVC) correlated positively with TID, reticular abnormality/honeycombing, and GGO. Conclusion: In IPF patients, the measurements of volume, diffusion, and dynamic compliance are the physiological variables which best reflect the extent of the interstitial disease on HRCT scans. (author)

  8. The Pattern of Significant Lesions Found in Computerized ...

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... Introduction: Seizures are common reasons for neurologic consultations and investigations. In the absence of magnetic resonance imaging, computerized tomography scanning of the brain is a reliable and cheaper alternative. Little is known about the pattern of brain lesions in patients with recurrent ...

  9. Craniofacial fibrous dysplasia: Report of a case using computed tomographic scan diagnosis

    Directory of Open Access Journals (Sweden)

    Nikhil Diwan

    2013-01-01

    Full Text Available Fibro-osseous lesions are benign mesenchymal tumors in which mineralized tissue, blood vessels, and giant cells, in varying proportions, replace normal bone. Although this group of lesions includes reactive lesions, harmatomas, and neoplasms, they cannot be distinguished only on the basis of the histopathology which can only confirm their common fibro-osseous nature. Definitive diagnosis requires thorough radiological evaluation. Computed tomographic images of craniofacial fibrous dysplasia on bone windows may be helpful and allow precise pre-operative diagnosis and surgical planning.

  10. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  11. Occult fractures of the knee: tomographic evaluation

    International Nuclear Information System (INIS)

    Apple, J.S.; Martinez, S.; Allen, N.B.; Caldwell, D.S.; Rice, J.R.

    1983-01-01

    Seven adults with painful effusions of the knee were examined for occult fractures using pluridirectional tomograph in the coronal and lateral planes. Six patients (ages 50 to 82 years) were osteopenic and gave histories ranging from none to mild trauma; one 26-year-old man was not osteopenic and had severe trauma. In all cases, routine radiographs were interpreted as negative, but tomography demonstrated a fracture. Five fractures were subchondral. Bone scans in 2 patients were positive. The authors conclude that osteopenic patients with a painful effusion of the knee should be considered to have an occult fracture. While bone scans may be helpful, tomography is recommended as the procedure of choice to define the location and extent of the fracture

  12. Ovarian metastases: Computed tomographic appearances

    International Nuclear Information System (INIS)

    Megibow, A.J.; Hulnick, D.H.; Bosniak, M.A.; Balthazar, E.J.

    1985-01-01

    Computed tomographic scans of 34 patients with ovarian metastases were reviewed to assess the radiographic appearances and to correlate these with the primary neoplasms. Primary neoplasms were located in the colon (20 patients), breast (six), stomach (five), small bowel (one), bladder (one), and Wilms tumor of the kidney (one). The radiographic appearance of the metastatic lesions could be described as predominantly cystic (14 lesions), mixed (12 lesions), or solid (seven lesions). The cystic and mixed lesions tended to be larger in overall diameter than the solid. The metastases from gastric carcinoma appeared solid in four of five cases. The metastases from the other neoplasms had variable appearances simulating primary ovarian carcinoma

  13. Unusual presentation of a large pituitary tumour in relation to diving.

    OpenAIRE

    Bakheit, A. M.; Kennedy, P. G.

    1989-01-01

    A case of necrosis of a pituitary tumour occurring in the context of diving is described. The presenting features and subsequent course suggested a brain stem vascular event. The tumour was not detected by routine computerized tomographic scanning, but was identified with magnetic resonance imaging. The possible pathophysiological mechanism is discussed.

  14. Interictal "patchy" regional cerebral blood flow patterns in migraine patients. A single photon emission computerized tomographic study

    DEFF Research Database (Denmark)

    Friberg, L; Olesen, J; Iversen, Helle Klingenberg

    1994-01-01

    In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right-left asymme......In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right...... rCBF images is insufficient to pick up abnormalities; (2) almost 50% of the migraine sufferers had abnormal rCBF/asymmetries. However, these are discrete compared with those typically seen during the aura phase of a migraine attack. One explanation to the patchy rCBF patterns might...

  15. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The objects of this invention are first to reduce the time required to obtain statistically significant data in trans-axial tomographic radioisotope scanning using a scintillation camera. Secondly, to provide a scintillation camera system to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a known radiation source without sacrificing spatial resolution. Thirdly to reduce the scanning time without loss of image clarity. The system described comprises a scintillation camera detector, means for moving this in orbit about a cranial-caudal axis relative to a patient and a collimator having septa defining apertures such that gamma rays perpendicular to the axis are admitted with high spatial resolution, parallel to the axis with low resolution. The septa may be made of strips of lead. Detailed descriptions are given. (U.K.)

  16. Computerized tomography system

    International Nuclear Information System (INIS)

    Hellstrom, M.; Kutlik, E.; Perlin, A.

    1980-01-01

    A method for non-mechanically linking the motions of an x-ray source with an x-ray receptor during a tomographic procedure to produce a tomograph of a section of an object under examination comprising the steps of: effecting motion of said source and receptor to respective reference positions; thereafter during a tomographic procedural mode generating from at least one fixed frequency signal source first and second pulse trains, adapted to drive respective stepper motors, for effecting motion of said source and receptor, said pulse trains having a predetermined mathematical relationship dependent upon the desired fulcrum height of the tomographic section to be produced; and applying said first and second pulse trains to the respective stepper motors for a predetermined number of pulse counts to effect motion with respect to said respective reference positions and effecting a tomographic sweep thereby

  17. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors.

    Science.gov (United States)

    Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun

    2017-04-05

    Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and -1.716 for liver, -0.153 and -1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P> 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = -8.11 for liver, -7.83 for pancreas, and -5.38 for renal cortex, all P 3, indicating clinically acceptable image quality. Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality.

  18. Computed tomographic diagnosis of abdominal abscess in childhood

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Berger, P.E.

    1980-01-01

    Twenty-eight children suspected clinically of having an abdominal abscess were examined by CT. Eighteen had gallium 67 citrate scans and 22 had ultrasound studies. Computed tomography was found to be the most accurate test for diagnosis and evaluation of an abscess and the computed tomographic appearance of abscess is illustrated. However, because of cost factors, radiation dose, and clinical considerations, computed tomography is not always the first modality of choice in evaluating a suspected abdominal abscess [fr

  19. Health physics aspects of the EMI computerized tomography brain scanner

    International Nuclear Information System (INIS)

    Villafana, T.; Scouras, J.; Kirkland, L.; McElroy, N.; Paras, P.

    1978-01-01

    The EMI computerized tomographic cranial scanner is one of the first radiological systems incorporating an on-line computer. The result is an increase in the ability to visualize such tissues as grey matter and white matter as well as blood pools and tumor volumes. This advance has already begun to revolutionize radiological practice. Because of the totally different configuration of this unit, concern has been expressed over the dosages received by the patient, consequently the health physics aspects of this unit have been studied. Specifically, doses received by the surface of head and interior brain points as well as by the lens of the eye and gonads are reported here. X-ray output, beam half-value layers and barrier shielding requirements are also reported and discussed. (author)

  20. Collimator trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    Jaszczak, Ronald J.

    1979-01-01

    An improved collimator is provided for a scintillation camera system that employs a detector head for transaxial tomographic scanning. One object of this invention is to significantly reduce the time required to obtain statistically significant data in radioisotope scanning using a scintillation camera. Another is to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a radiation source of known strength without sacrificing spatial resolution. A further object is to reduce the necessary scanning time without degrading the images obtained. The collimator described has apertures defined by septa of different radiation transparency. The septa are aligned to provide greater radiation shielding from gamma radiation travelling within planes perpendicular to the cranial-caudal axis and less radiation shielding from gamma radiation travelling within other planes. Septa may also define apertures such that the collimator provides high spatial resolution of gamma rays traveling within planes perpendicular to the cranial-caudal axis and directed at the detector and high radiation sensitivity to gamma radiation travelling other planes and indicated at the detector. (LL)

  1. X-ray Tomographic Microscopy at TOMCAT

    Energy Technology Data Exchange (ETDEWEB)

    Marone, F; Hintermueller, C; McDonald, S; Abela, R; Mikuljan, G; Isenegger, A; Stampanoni, M, E-mail: federica.marone@psi.c [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland)

    2009-09-01

    Synchrotron-based X-ray Tomographic Microscopy is a powerful technique for fast non-destructive, high resolution quantitative volumetric investigations on diverse samples. At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline at the Swiss Light Source, synchrotron light is delivered by a 2.9 T superbend. The main optical component, a Double Crystal Multilayer Monochromator, covers an energy range between 8 and 45 keV. The standard TOMCAT detector offers field of views ranging from 0.75x0.75 mm{sup 2} up to 12.1x12.1 mm{sup 2} with a pixel size of 0.37 {mu}m and 5.92 {mu}m, respectively. In addition to routine measurements, which exploit the absorption contrast, the high coherence of the source also enables phase contrast tomography, implemented with two complementary techniques (Modified Transport of Intensity approach and Grating Interferometry). Typical acquisition times for a tomogram are in the order of few minutes, ensuring high throughput and allowing for semi-dynamical investigations. Raw data are automatically post-processed online and full reconstructed volumes are available shortly after a scan with minimal user intervention.

  2. Roentgen and X-ray computerized tomographic (CT) imaging of cysts in the maxilla

    International Nuclear Information System (INIS)

    Rahmatulla, M

    1999-01-01

    Two cysts in the maxilla were subjected to routine roentgen imaging followed by CT scanning. Roentgen investigation included periapical, occlusal, and panoramic views. CT imaging included axial and coronal scans. While roentgen views were adequate in establishing the diagnosis of the cystic lesions, CT scan was useful in understanding the precise antero-posterior expansion and depth of the lesion. Interpretation of CT scan of cystic jaw lesions without con-ventional radiographs can be misleading. Hence, the CT procedure may be used only as supplement to the routine radiographic investigations particularly in cystic lesions of the jaws. (author)

  3. Comparison of capacity for diagnosis and visuality of auditory ossicles at different scanning angles in the computed tomography of temporal bone

    International Nuclear Information System (INIS)

    Ogura, Akio; Nakayama, Yoshiki

    1992-01-01

    Computed tomographic (CT) scanning has made significant contributions to the diagnosis and evaluation of temporal bone lesions by the thin-section, high-resolution techniques. However, these techniques involve greater radiation exposure to the lens of patients. A mean was thus sought for reducing the radiation exposure at different scanning angles such as +15 degrees and -10 degrees to the Reid's base line. Purposes of this study were to measure radiation exposure to the lens using the two tomographic planes and to compare the ability to visualize auditory ossicles and labyrinthine structures. Visual evaluation of tomographic images on auditory ossicles was made by blinded methods using four rankings by six radiologists. The statistical significance of the intergroup difference in the visualization of tomographic planes was assessed for a significance level of 0.01. Thermoluminescent dosimeter chips were placed on the cornea of tissue equivalent to the skull phantom to evaluate radiation exposure for two separate tomographic planes. As the result, tomographic plane at an angle of -10 degrees to Reid's base line allowed better visualization than the other plane for the malleus, incus, facial nerve canal, and tuba auditiva (p<0.01). Scannings at an angle of -10 degrees to Reid's base line reduced radiation exposure to approximately one-fiftieth (1/50) that with the scans at the other angle. (author)

  4. [Indications and instructions to patients for a positron emission tomography-PET scan. The importance of the hybridic PET/CT-computerised tomography scan and which specialty should be responsible for its function].

    Science.gov (United States)

    Grammaticos, Philip; Datseris, Ioannis; Gerali, Sofia; Papantoniou, Vassilios; Valsamaki, Pipitsa; Boundas, Dimitrios

    2007-01-01

    Indications and instructions to patients for performing a positron emission tomography - PET scan are mentioned. Although PET camera was developed in 1970 its clinical indications were established in about 1998. The hybridic PET/CT- computerized tomography scanner appeared in 2001 and its clinical indications are still under discussion. These discussions refer to both the use of PET/CT as an acquisition correction and anatomic localization device for PET images (AC/A) and to its use as a diagnostic CT scan (dCT). Most of the patients submitted for a PET scan have already done a dCT scan. This was the case in 286 out of the first 300 patients referred to "Evangelismos" hospital in Athens for a PET scan. These two scans can be matched electronically. Extra cost, space, personnel and radiation absorption dose especially in children, are additional factors to be considered in using the PET/CT scanner. The specialty of Nuclear Medicine is now based on the PET camera, its best part and main equipment for molecular imaging. It is very much easier and faster for a Nuclear Medicine physician who routinely reports tomographic PET and SPET images, to be familiar with the CT images than for a Radiologist to get to "know how" about the PET camera and the whole Nuclear Medicine Department. Nuclear Medicine is about open radiation sources, molecular imaging, specific radio-pharmacology, radiobiology, radiation protection etc, while on the other hand in some countries, Nuclear Physicians have already spent, as part of their official training, six months in a Radiology Department whose function is considered to be at least 25% about the CT scanner. We come to the conclusion that the PET/CT scanner should be under the responsibility of the Nuclear Medicine Department and the Radiologist should act as an advisor.

  5. The sacral foramina

    International Nuclear Information System (INIS)

    Jackson, H.; Burke, J.T.

    1984-01-01

    The sacral foramina, particularly the first three, are not simple fenestrations. Each foramen is a Y-shaped complex of canals, all with indefinite margins. The complexes lie obliquely at approximately 45 0 to the coronal plane. An appreciation of these facts facilitates the recognition of the anatomy of plain films, tomographs, and computerized scans. (orig.)

  6. Mobile 3D tomograph

    International Nuclear Information System (INIS)

    Illerhaus, Bernhard; Goebbels, Juergen; Onel, Yener; Sauerwein, Christoph

    2008-01-01

    Mobile tomographs often have the problem that high spatial resolution is impossible owing to the position or setup of the tomograph. While the tree tomograph developed by Messrs. Isotopenforschung Dr. Sauerwein GmbH worked well in practice, it is no longer used as the spatial resolution and measuring time are insufficient for many modern applications. The paper shows that the mechanical base of the method is sufficient for 3D CT measurements with modern detectors and X-ray tubes. CT measurements with very good statistics take less than 10 min. This means that mobile systems can be used, e.g. in examinations of non-transportable cultural objects or monuments. Enhancement of the spatial resolution of mobile tomographs capable of measuring in any position is made difficult by the fact that the tomograph has moving parts and will therefore have weight shifts. With the aid of tomographies whose spatial resolution is far higher than the mechanical accuracy, a correction method is presented for direct integration of the Feldkamp algorithm [de

  7. Development and prospects of X-ray computerized tomography. I

    International Nuclear Information System (INIS)

    Dobes, V.

    1985-01-01

    The history and developmental trends are described of X-ray computerized tomography (CT) as are its applications in clinical practise. Suitable criteria and economic aspects are proposed for the choice of CT systems. The types are listed and described of X-ray CT systems, including brain, whole-body, mobile and special systems. A table is given showing available specifications (types of detectors, X-ray source, resolution, configuration, scan angles, scan fields, image reconstruction, etc.) for machines by different companies. (M.D.)

  8. Combining operando synchrotron X-ray tomographic microscopy and scanning X-ray diffraction to study lithium ion batteries

    Science.gov (United States)

    Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa

    2016-06-01

    We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions.

  9. Combining operando synchrotron X-ray tomographic microscopy and scanning X-ray diffraction to study lithium ion batteries

    Science.gov (United States)

    Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa

    2016-01-01

    We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions. PMID:27324109

  10. Computed tomographic diagnosis of calcified inferior vena cava thrombus in a child with Wilm's tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kirks, D R; Ponzi, J W; Korobkin, M

    1980-01-01

    A calcified thrombus in the inferior vena cava of infants and children may be imaged by computed tomography. The precise location of the calcification within the inferior vena cava may be confirmed by computed tomographic scanning during injection of intravenous contrast material.

  11. Tomography system having axial scanning

    International Nuclear Information System (INIS)

    1976-01-01

    An improved method and apparatus has been invented for the transaxial tomographic scanning of a patient to determine mass distribution internal to the patient. A scanning system is provided having a rotatably mounted X-ray radiation source/detector assembly which orbits and scans the patient in plane of orbit. The source provides a plurality of beams of radiation in the orbital plane. Beams pass through the patient to an array of detectors which are spaced in the plane of orbit and respectively aligned with one of the beams. Radiation intensity data is collected at predetermined orientations of each beam-detector pair as the assembly orbits about the patient

  12. Performance of confocal scanning laser tomograph Topographic Change Analysis (TCA) for assessing glaucomatous progression.

    Science.gov (United States)

    Bowd, Christopher; Balasubramanian, Madhusudhanan; Weinreb, Robert N; Vizzeri, Gianmarco; Alencar, Luciana M; O'Leary, Neil; Sample, Pamela A; Zangwill, Linda M

    2009-02-01

    To determine the sensitivity and specificity of confocal scanning laser ophthalmoscope's Topographic Change Analysis (TCA; Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany) parameters for discriminating between progressing glaucomatous and stable healthy eyes. The 0.90, 0.95, and 0.99 specificity cutoffs for various (n=70) TCA parameters were developed by using 1000 permuted topographic series derived from HRT images of 18 healthy eyes from Moorfields Eye Hospital, imaged at least four times. The cutoffs were then applied to topographic series from 36 eyes with known glaucomatous progression (by optic disc stereophotograph assessment and/or standard automated perimetry guided progression analysis, [GPA]) and 21 healthy eyes from the University of California, San Diego (UCSD) Diagnostic Innovations in Glaucoma Study (DIGS), all imaged at least four times, to determine TCA sensitivity and specificity. Cutoffs also were applied to 210 DIGS patients' eyes imaged at least four times with no evidence of progression (nonprogressed) by stereophotography or GPA. The TCA parameter providing the best sensitivity/specificity tradeoff using the 0.90, 0.95, and 0.99 cutoffs was the largest clustered superpixel area within the optic disc margin (CAREA(disc) mm(2)). Sensitivities/specificities for classifying progressing (by stereophotography and/or GPA) and healthy eyes were 0.778/0.809, 0.639/0.857, and 0.611/1.00, respectively. In nonprogressing eyes, specificities were 0.464, 0.570, and 0.647 (i.e., lower than in the healthy eyes). In addition, TCA parameter measurements of nonprogressing eyes were similar to those of progressing eyes. TCA parameters can discriminate between progressing and longitudinally observed healthy eyes. Low specificity in apparently nonprogressing patients' eyes suggests early progression detection using TCA.

  13. A tomographic approach to intravenous coronary arteriography

    International Nuclear Information System (INIS)

    Ritman, E.L.; Bove, A.A.

    1986-01-01

    Coronary artery anatomy can be visualized using high speed, volume scanning X-ray CT. A single scan during a bolus injection of contrast medium provides image data for display of all angles of view of the opacified coronary arterial tree. Due to the tomographic nature of volume image data the superposition of contrast filled cardiac chambers, such as would occur in the levophase of an intravenous injection of contrast agent, can be eliminated. Data are presented which support these statements. The Dynamic Spatial Reconstructor (DSR) was used to scan a life-like radiologic phantom of an adult human thorax in which the left atrial and ventricular chambers and the major epicardial coronary arteries were opacified so as to simulate the levophase of an intravenous injection of contrast agent. A catheter filled with diluted contrast agent and with regions of luminal narrowing (i.e. 'stenoses') was advanced along a tract equivalent to a right ventricular catheterization. Ease of visualization of the catheter 'stenoses' and the accuracy with which they can be measured are presented. (Auth.)

  14. Staging of bronchogenic carcinoma by computerized tomography

    International Nuclear Information System (INIS)

    Sommer, B.; Bauer, W.M.; Rath, M.; Fenzl, G.; Stelter, W.J.; Lissner, J.

    1981-01-01

    It was possible to check the information obtained by CT scanning in 36 patients out of 49 who had been subjected to computerized tomography, in respect of the extension of the primary tumour (T stage), and in 25 patients in respect of the degree of mediastinal lymphatic node involvement (N stage). In all 49 patients, the presence of bronchogenic carcinoma had been safely established. In 97% of the cases, assessment of the extension of the primary tumour was found to be correct. Assessment of the N stage, however, is more problematic, since detection of mediastinal lymphatic nodes by computerized tomography does not necessarily tell us something about their metastatic involvement. If all recognizable lymphatic nodes are interpreted as potential metastases, we have no false negative but 61% false positive results because of the frequency of postinflammatory or anthracotic lymphatic nodes. In case of exclusive assessment of lymphatic node enlargement above 1 cm diameter, the rate of metastatic nodes increases considerably (83%). Computerized tomography is definitely superior to all roentgenological methods in assessing the stage of a bronchogenic carcinoma; hence, it could occupy a key position in determining the diagnostic and therapeutic approach in patients with this disease. (orig.) [de

  15. Design of a volume-imaging positron emission tomograph

    International Nuclear Information System (INIS)

    Harrop, R.; Rogers, J.G.; Coombes, G.H.; Wilkinson, N.A.; Pate, B.D.; Morrison, K.S.; Stazyk, M.; Dykstra, C.J.; Barney, J.S.; Atkins, M.S.; Doherty, P.W.; Saylor, D.P.

    1988-11-01

    Progress is reported in several areas of design of a positron volume imaging tomograph. As a means of increasing the volume imaged and the detector packing fraction, a lens system of detector light coupling is considered. A prototype layered scintillator detector demonstrates improved spatial resolution due to a unique Compton rejection capability. The conceptual design of a new mechanism for measuring scattered radiation during emission scans has been tested by Monte Carlo simulation. The problem of how to use effectively the resulting sampled scattered radiation projections is presented and discussed

  16. Value of the computerized axial tomography for early diagnosis of cranio cerebral trauma

    International Nuclear Information System (INIS)

    Rodriguez Cheong, Maricel; Dosouto Infante, Vivian; Rosales Fargie, Yamile

    2010-01-01

    A descriptive and cross-sectional study was conducted in 62 patients with cranio cerebral trauma admitted to 'Saturnino Lora' Provincial Teaching Hospital of Santiago de Cuba, from January 2005 to May 2006, in whom computerized axial tomography indicated at the emergency room was performed with the purpose of evaluating the effectiveness of this radiographic technique for early diagnosis of the injury. In the case material there was neither association between the source and imaging results, nor between the age and sex. The main clinical manifestations were vomiting, headache and motor deficit as well as frontal location, intraparenchymatous hematoma (the latter as the most common image finding) and the hyperdense area as tomographic pattern. The survival was of 91,9%

  17. Gas microstrip detectors for X-ray tomographic flow imaging

    CERN Document Server

    Key, M J; Luggar, R D; Kundu, A

    2003-01-01

    A investigation into the suitability of gas microstrip detector technology for a high-speed industrial X-ray tomography system is reported. X-ray energies in the region 20-30 keV are well suited to the application, which involves imaging two-dimensional slices through gas/liquid multiphase pipeline flows for quantitative component fraction measurement. Stable operation over a period representing several hundred individual tomographic scans at gas gains of 500 is demonstrated using a Penning gas mixture of krypton/propylene.

  18. Getting a CAT Scan (For Kids)

    Medline Plus

    Full Text Available ... site Sitio para adolescentes Body Mind Sexual Health Food & ... stands for "computerized axial tomography." Translated, that means a scanner takes computer pictures of what's going on inside your body. The scan itself ...

  19. Advances in tomographic PIV

    NARCIS (Netherlands)

    Novara, M.

    2013-01-01

    This research deals with advanced developments in 3D particle image velocimetry based on the tomographic PIV technique (Tomo-PIV). The latter is a relatively recent measurement technique introduced by Elsinga et al. in 2005, which is based on the tomographic reconstruction of particle tracers in

  20. Effects of megavoltage computed tomographic scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy.

    Science.gov (United States)

    Zhu, Jian; Bai, Tong; Gu, Jiabing; Sun, Ziwen; Wei, Yumei; Li, Baosheng; Yin, Yong

    2018-04-27

    To evaluate the effect of pretreatment megavoltage computed tomographic (MVCT) scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy. Both anthropomorphic heterogeneous chest and pelvic phantoms were planned with virtual targets by TomoTherapy Physicist Station and were scanned with TomoTherapy megavoltage image-guided radiotherapy (IGRT) system consisted of six groups of options: three different acquisition pitches (APs) of 'fine', 'normal' and 'coarse' were implemented by multiplying 2 different corresponding reconstruction intervals (RIs). In order to mimic patient setup variations, each phantom was shifted 5 mm away manually in three orthogonal directions respectively. The effect of MVCT scan options was analyzed in image quality (CT number and noise), adaptive dose calculation deviations and positional correction variations. MVCT scanning time with pitch of 'fine' was approximately twice of 'normal' and 3 times more than 'coarse' setting, all which will not be affected by different RIs. MVCT with different APs delivered almost identical CT numbers and image noise inside 7 selected regions with various densities. DVH curves from adaptive dose calculation with serial MVCT images acquired by varied pitches overlapped together, where as there are no significant difference in all p values of intercept & slope of emulational spinal cord (p = 0.761 & 0.277), heart (p = 0.984 & 0.978), lungs (p = 0.992 & 0.980), soft tissue (p = 0.319 & 0.951) and bony structures (p = 0.960 & 0.929) between the most elaborated and the roughest serials of MVCT. Furthermore, gamma index analysis shown that, compared to the dose distribution calculated on MVCT of 'fine', only 0.2% or 1.1% of the points analyzed on MVCT of 'normal' or 'coarse' do not meet the defined gamma criterion. On chest phantom, all registration errors larger than 1 mm appeared at superior-inferior axis, which cannot be avoided with the smallest AP and RI

  1. Variation in Location of the Mandibular Foramen/Inferior Alveolar Nerve Complex Given Anatomic Landmarks Using Cone-beam Computed Tomographic Scans.

    Science.gov (United States)

    Blacher, Jonathan; Van DaHuvel, Scott; Parashar, Vijay; Mitchell, John C

    2016-03-01

    The inferior alveolar nerve (IAN) injection is 1 of the most commonly administered and useful injections in the field of dentistry. Practitioners use intraoral anatomic landmarks, which vary greatly among patients. The objective of this study was to assist practitioners by identifying a range of normal variability within certain landmarks used in delivering IAN anesthesia. A total of 203 randomly selected retrospective cone-beam computed tomographic scans were obtained from the Midwestern University Dental Institute cone-beam computed tomographic database. InVivoDental5.0 volumetric imaging software (Anatomage, San Jose, CA) was used to measure 2 important parameters used in locating the mandibular foramen (MF)/IAN complex: (1) the angle from the contralateral premolar contact area to the MF and (2) the distance above the mandibular occlusal plane to the center of the MF. The variation of these measurements was compared with established reference values and statistically analyzed using a 1-sample t test. The angle from the contralateral premolar contact area to the MF for the right and left sides was 42.99° and 42.57°, respectively. The angulations varied significantly from the reference value of 45° (P < .001). The minimum height above the mandibular occlusal plane for the right and left sides was 9.85 mm and 9.81 mm, respectively. The heights varied significantly from the minimum reference value of 6 mm but not the maximum reference value of 10 mm (P < .001). Orienting the syringe barrel at an angulation slightly less than 45° and significantly higher than 6 mm above the mandibular occlusal plane can aid in successfully administering anesthesia to the MF/IAN complex. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. The computed tomographic appearance of cerebral cysticercosis in adults and children

    International Nuclear Information System (INIS)

    Byrd, S.E.; Locke, G.E.; Biggers, S.; Percy, A.K.

    1982-01-01

    The computed tomographic (CT) scans of 45 patients (30 adults, 15 children) with cerebral cysticercosis were reviewed. These patients had undergone complete diagnostic evaluations including skin tests, laboratory tests, plain skull radiography, radionuclide brain scanning, CT, and cerebral angiography. All of these tests were unrewarding except CT and the indirect hemagglutination tests on the serum. A classification of cerebral cysticercosis based on the location of the lesions in the brain and the CT appearance was developed. Cerebral cysticercosis can be diagnosed by CT findings when there is also a history of seizures and of the patient having lived in an area where the disease is endemic

  3. The influence of the periodontal biotype on peri-implant tissues around immediate implants with and without xenografts. Clinical and micro-computerized tomographic study in small Beagle dogs.

    Science.gov (United States)

    Maia, Luciana P; Reino, Danilo M; Muglia, Valdir A; de Souza, Sérgio L S; Palioto, Daniela B; Novaes, Arthur B

    2015-01-01

    Soft tissues and buccal bone plate remodeling after immediate implantation in sockets with thin buccal bone, using the flapless approach with or without bone graft into the buccal gap, was compared between sites with thin and normal gingiva. Eight dogs had the gingiva of one side of the mandible thinned, the mandibular premolars were extracted without flaps, and 4 implants were installed in each side, positioned 1.5 mm from the buccal bone. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). Buccal bone thickness (BBT), thickness of keratinized tissue (TKT), alveolar thickness (AT), gingival recession (GR), and probing depth (PD) were clinically evaluated. Within 12 weeks the dogs were sacrificed and the samples were analyzed by micro-computerized tomography. A thin BBT was observed in all the dogs. The presurgical procedures reduced TKT in the test group, with minimal changes of the AT. There were no statistically significant differences among the groups for the clinical parameters and the tomographic analysis showed similar linear and tri-dimensional bone reduction in all the groups. The thickness of the buccal bone was a fundamental factor in buccal bone plate resorption, even with flapless implantation. The decrease in gingival thickness or the addition of a biomaterial in the gap did not influence the results. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Role of computerized tomography in diagnosis of atypical gall bladder and common bile duct stones

    International Nuclear Information System (INIS)

    El-Husseni, Tareq K.; Al-Shebrein, Ibrahim A.

    2001-01-01

    Objective was to assess the value of computerized tomography as an adjuvant to ultrasound in the diagnosis of atypical gallbladder and common duct stone disease. Real time ultrasound scanning for the gallbladder and common duct was performed in the routine manner. High resolution computerized tomography images were subsequently obtained for the region of interest. Computerized tomography resolved undetermined results as follows: 1. Non shadowing gallbladder debris (6 points), 2. Focal gallbladder wall thickening (2 points), 3. Stone obscured by calcified gallbladder wall (3 points), 4. Non visualized gallbladder double arc shadow (4 points), 5 and 6. Impacted gallbladder neck and common duct stones (18 points), computerized tomography gave false positive diagnosis in (2 points). Computerized tomography provided an effective and reliable means for the diagnosis of atypical gallbladder calculi when ultrasound was imprecise or the findings contradicted the clinical presentation. Finally if gallbladder neck or common duct stones are suspected, in addition to computerized tomography other imaging techniques such as magnetic resonance cholangio pancreatography or endoscopic retrograde cholangiopancreatography in addition to computerized tomography may be needed to avoid false positive diagnosis prior to surgery. (author)

  5. Comparative study of the macroscopic finding, conventional tomographic imaging, and computed tomographic imaging in locating the mandibular canal

    International Nuclear Information System (INIS)

    Choi, Hang Moon; You, Dong Soo

    1995-01-01

    The purpose of this study was comparison of conventional tomography with reformatted computed tomography for dental implant in locating the mandibular canal. Five dogs were used and after conventional tomographs and fitted computed tomographs were taken, four dentist traced all films. Mandibles were sectioned with 2 mm slice thickness and the sections were then radiographed (contact radiography). Each radiograpic image was traced and linear measurements were made from mandibular canal to alveolar crest, buccal cortex, lingual cortex, and inferior border. The following results were obtained; 1. Reformatted computed tomographs were exacter than conventional tomography by alveolar crest to canal length of -0.6 mm difference between real values and radiographs 2. The average measurements of buccal cortex to mandibular canal width and lingual cortex to mandibular canal width of conventional tomographs were exacter than reformatted computed tomographs, but standard deviations were higher than reformatted computed tomographs. 3. Standard deviations of reformatted computed tomographs were lower than conventional tomographs at all comparing sites 4. At reformatted computed tomography 62.5% of the measurements performed were within ±1 mm of the true value, and at conventional tomography 24.1% were. 5. Mandibular canal invisibility was 0.8% at reformatted computed tomography and 9.2% at conventional tomography. Reformatted computed tomography has been shown to be more useful radiographic technique for assessment of the mandibular canal than conventional tomography.

  6. Comparison of computerized tomography to sonography, applied in diseases of the pancreas

    International Nuclear Information System (INIS)

    Kluge, K.

    1982-01-01

    The examination results of 418 patients whose epigastria had been examined both by computerized tomography and sonography over 1 week in the time from beginning January 1978 until and of July 1979 were compared with regard to the imaging of the pancreas, reliability, and the specificity and sensitivity in establishing the diagnosis. For the sonographic examination, a compound and a real-time unit were used; the computerized tomography was carried out by means of an equipment of the 3rd generation with a scan time of 4 sec. The screening of the pancreas was significantly better using computerized tomography (99.3% US. 84% with US). As for accuracy, computerized tomography had 92.5% exact diagnoses versus 79.9% obtained by sonography. If, however, we look at the cases in which the pancreas could be screened with both methods the accuracy was almost the same (93.7 CT and 93.3% US). Specificity was almost of the same quality, however, the method of computerized tomography with 0.963 was slightly better than ultrasound with 0.943. As for sensitivity, sonography with 0.838 was better than CT with 0.721. The reason for that is the fact that a big part of the chronic pancreatites (30.3%) were not recognized by means of computerized tomography. (orig.) [de

  7. Advanced Ultrasonic Tomograph of Children's Bones

    Science.gov (United States)

    Lasaygues, Philippe; Lefebvre, Jean-Pierre; Guillermin, Régine; Kaftandjian, Valérie; Berteau, Jean-Philippe; Pithioux, Martine; Petit, Philippe

    This study deals with the development of an experimental device for performing ultrasonic computed tomography (UCT) on bone in pediatric degrees. The children's bone tomographs obtained in this study, were based on the use of a multiplexed 2-D ring antenna (1 MHz and 3 MHz) designed for performing electronic and mechanical scanning. Although this approach is known to be a potentially valuable means of imaging objects with similar acoustical impedances, problems arise when quantitative images of more highly contrasted media such as bones are required. Various strategies and various mathematical procedures for modeling the wave propagation based on Born approximations have been developed at our laboratory, which are suitable for use with pediatric cases. Inversions of the experimental data obtained are presented.

  8. A preprocessor for geotomographic imaging of irregular geometric scans

    International Nuclear Information System (INIS)

    Middleton, N.T.; Harman, M.T.

    1992-01-01

    Conventional tomographic image reconstruction algorithms that use algebraic methods are best suited to rectangular geometries. Although this is satisfactory for many rectangular cross-hole and in-seam geotomographic scans, difficulties arise in cases where the scanning geometry is nonrectangular. This paper describes a preprocessing algorithm that deals with nonrectangular geometries when merged with a conventional image reconstruction algorithm. The performance of the preprocessing algorithm is demonstrated with some simulation results

  9. Computerized tomography used in non-destructive testing of welded pipes

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, M; Rizescu, C; Georgescu, G; Marinescu, A; Chitescu, P; Sava, T; Neagu, M; Avram, D [Institute of Research and Design for Electrical Engineering, ICPE - Electrostatica Splaiul Unirii 313, Sect. 3, R-74204 Bucharest (Romania)

    1997-12-31

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using {gamma}-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or {gamma}-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: (1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., (2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs.

  10. Computerized tomography used in non-destructive testing of welded pipes

    International Nuclear Information System (INIS)

    Iovea, M.; Rizescu, C.; Georgescu, G.; Marinescu, A.; Chitescu, P.; Sava, T.; Neagu, M.; Avram, D.

    1996-01-01

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using γ-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or γ-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: 1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., 2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs

  11. CT scan for the diagnosis of maxillary sinus carcinoma

    International Nuclear Information System (INIS)

    Kimura, Yo; Kato, Isao; Aoyagi, Masaru; Kikuchi, Akira; Koike, Yoshio; Suzuki, Hachiro.

    1984-01-01

    A comparative study between the conventional radiological examination and the computed tomographical examination for the diagnosis of maxillary sinus carcinoma was done. CT scan has been more appreciated to detect the tumor invasion in the pterygopalatine fossa, orbit, posterior ethmoid sinus and skull base than the conventional examination. CT scan was most usefull for the determination of size and location of the tumor. The prognosis by the stage-grouping was significantly separated by the new classification with CT scan. Therefore, new TNM classification of maxillary sinus carcinoma with CT scan should be taken into account. (author)

  12. The application of real-time, non-destructive electrical tomographic imaging to heritage conservation

    OpenAIRE

    Ogilvy, Richard

    2008-01-01

    Significant advances have been made in recent times with the non-invasive electrical tomographic imaging of the shallow subsurface. These emerging technologies are analogous to magnetic resonance imaging (MRI) or CT scans used in medical physics. Electrical Resistivity Tomography (ERT) is increasingly used to underpin studies in waste management, contaminated land characterisation and remediation, monitoring groundwater resources and the monitoring of geohazards or safety-critical plant. Ther...

  13. Radiation imaging apparatus

    International Nuclear Information System (INIS)

    1979-01-01

    This invention relates to a radiation imaging apparatus. It relates more particularly to apparatus of this general type which employs stationary X-ray source and detector arrays capable of acquiring multiple ultrafast scans per second to facilitate the dynamic study of moving human organs such as the beating heart. While the invention has many applications, it has particular utility in connection with computerized tomographic (CT) scanners. (Auth.)

  14. A Micro-Scale Investigation on the Behaviors of Asphalt Mixtures under Freeze-Thaw Cycles Using Entropy Theory and a Computerized Tomography Scanning Technique

    Directory of Open Access Journals (Sweden)

    Huining Xu

    2018-01-01

    Full Text Available The thermodynamic behavior of asphalt mixtures is critical to the engineers since it directly relates to the damage in asphalt mixtures. However, most of the current research of the freeze-thaw damage of asphalt mixtures is focused on the bulk body from the macroscale and lacks a fundamental understanding of the thermodynamic behaviors of asphalt mixtures from the microscale perspective. In this paper, to identify the important thermodynamic behaviors of asphalt mixtures under freeze-thaw loading cycle, the information entropy theory, an X-ray computerized tomography (CT scanner and digital image processing technology are employed. The voids, the average size of the voids, the connected porosity, and the void number are extracted according to the scanned images. Based on the experiments and the CT scanned images, the information entropy evolution of the asphalt mixtures under different freeze-thaw cycles is calculated and the relationship between the change of information entropy and the pore structure characteristics is established. Then, the influences of different freezing and thawing conditions on the thermodynamic behaviors of asphalt mixtures are compared. The combination of information entropy theory and CT scanning technique proposed in this paper provides an innovative approach to investigate the thermodynamics behaviors of asphalt mixtures and a new way to analyze the freeze-thaw damage in asphalt mixtures.

  15. Computerized tomography of orbital lesions

    International Nuclear Information System (INIS)

    Kuroiwa, Mayumi

    1981-01-01

    Two different types of computerized tomography scanners (CT scanner), i.e. a whole-body CT scanner (GE-CT/T8800) and a cerebral CT scanner (EMI-1010), were compared in the assessment and diagnosis of various orbital lesions. The whole-body CT scanner was found to be advantageous over the cerebral CT scanner for the following reasons: (1) CT images were more informative due to thinner slices associated with smaller-sized and larger-numbered matrices; (2) less artifacts derived from motion of the head or eyeball were produced because of the shorter scanning time; (3) with a devised gantry, coronal dissections were available whenever demanded. (author)

  16. Clamshell tomograph

    International Nuclear Information System (INIS)

    Derenzo, S. E.; Budinger, Th. F.

    1984-01-01

    In brief, the invention is a tomograph modified to be in a clamshell configuration so that the ring or rings may be moved to multiple sampling positions. The tomograph includes an array of detectors arranged in successive adjacent relative locations along a closed curve in a first position in a selected plane, and means for securing the detectors in the relative locations in a first sampling position. The securing means is movable in the plane in two sections and pivotable at one point and only one point to enable movement of at least one of the sections to a second sampling position out of the closed curve so that the ends of the section which are opposite the point are moved apart a predetermined space

  17. Comparison of absorbed dose of two protocols of tomographic scanning in PET/CT exams; Comparação da dose absorvida de dois protocolos de varredura tomográfica em exame de PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, F.G., E-mail: fgpaiva92@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Santana, P.C. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina; Mourão Filho, A.P. [Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Positron Emission Tomography (PET) associated with Computed Tomography (CT) allows the fusion of functional and anatomical images. When compared to other diagnostic techniques, PET-CT subjects patients to higher levels of radiation, because two modalities are used in a single exam. In this study, the doses absorbed in 19 patient organs from the tomographic scan were evaluated. Radiochromic films were correctly positioned in the Alderson anthropomorphic simulator, male version. For evaluation, two whole body scan protocols were compared. For evaluation, two whole body scan protocols were compared. An increase of up to 600% in the absorbed dose in the pituitary was observed when the protocols were compared, with the lowest observed increase of approximately 160% for the liver. It is concluded that the dose from CT in patients submitted to PET-CT scanning is higher in the protocol used for diagnosis. Considering the high cost of PET-CT exam, in many cases it is preferable that the CT examination is of diagnostic quality, and not only for anatomical mapping, an argument based on the Principle of Justification.

  18. Feasibility study for image reconstruction in circular digital tomosynthesis (CDTS) from limited-scan angle data based on compressed-sensing theory

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yeonok; Je, Uikyu; Cho, Hyosung, E-mail: hscho1@yonsei.ac.kr; Hong, Daeki; Park, Chulkyu; Cho, Heemoon; Choi, Sungil; Woo, Taeho

    2015-03-21

    In this work, we performed a feasibility study for image reconstruction in a circular digital tomosynthesis (CDTS) from limited-scan angle data based on compressed-sensing (CS) theory. Here, the X-ray source moves along an arc within a limited-scan angle (≤ 180°) on a circular path set perpendicularly to the axial direction during the image acquisition. This geometry, compared to full-angle (360°) scan geometry, allows imaging system to be designed more compactly and gives better tomographic quality than conventional linear digital tomosynthesis (DTS). We implemented an efficient CS-based reconstruction algorithm for the proposed geometry and performed systematic simulations to investigate the image characteristics. We successfully reconstructed CDTS images with incomplete projections acquired at several selected limited-scan angles of 45°, 90°, 135°, and 180° for a given tomographic angle of 80° and evaluated the reconstruction quality. Our simulation results indicate that the proposed method can provide superior tomographic quality for axial view and even for the other views (i.e., sagittal and coronal), as in computed tomography, to conventional DTS. - Highlights: • Image reconstruction is done in circular digital tomosynthesis (CDTS). • The designed geometry allows imaging system to be the better image. • An efficient compressed-sensing (CS)-based reconstruction algorithm is performed. • Proposed method can provide superior tomographic quality for the axial view.

  19. Computerized tomographic evaluations of 37 cases of craniopharyngiomas

    International Nuclear Information System (INIS)

    Nagasawa, Shiro; Yamashita, Junkoh; Handa, Hajime; Takeuchi, Juji.

    1983-01-01

    Although craniopharyngiomas are well known to exhibit three basic CT characteristics: Calcification, cysts, and contrast enhancement (CE), several cases with atypical CT manifestations have been reported lately. These atypical manifestations can be classified into three groups: Unusual extensions of the tumors, high-density cysts, and marked homogeneous CE. The CT scans obtained in our recent series of 37 craniopharyngiomas were evaluated in an attempt to analyze the tumoral extensions, the cyst densities, and the CE, and were compared with those of other, rarer parasellar lesions. Cystic tumors were much more frequent than solid tumors (Table 1); 14 cases (38%) were exclusively cystic; 17 cases (46%), equally cystic and solid, and 6 cases (16%), solid. Calcifications were present in 86% of the children and 43% of the adults. Unusual extensions were noted in 7 cases (Fig. 1, 2): Anteriorly to the frontal fossa (5 cases, 14%), laterally to the temporal fossa (1 case, 3%), or posteriorly to the posterior fossa (1 case, 3%). All these tumors were either purely cystic or equally cystic and solid. Cystic portions were detected in the tumors of 31 cases (Table 2). Although the majority of the cystic portions (25 cases, 81%) were low in density, isodense cysts were observed in 6 cases (19%). Out of 23 cases exhibiting solid portions in the tumors, high-density areas (calcified masses) were detected in 3 cases and mixed-density areas in 20 cases. While these 20 cases all showed CE, marked homogeneous CE were noted in 5 cases (25%). (J.P.N.)

  20. Axial tomographic system for radiation diagnoses

    International Nuclear Information System (INIS)

    Crowther, T.J.

    1977-01-01

    The axial tomographic scanner consists of a source of hard radiation passing a fan shaped beam through a plane layer of the body under examination, a detector, and driving systems for the sequential displacement and rotation of the radiation source and the detector. The diagnosis is made by means of a data processing system offering extensive time overlap capability of the individual system functions. The data sets from transmission or absorption are processed in three independent subsystems, i.e., the scanning system, the processing system and the display system. The systems are made up of well-known modules, e.g., Nova 1200 or Eclipse 5200. Hence, as a result of the independent design of the data system, raw data will not be lost in case of faults in some subsystem. (DG) [de

  1. Tomographic X-ray apparatus for the production of transverse layer images

    International Nuclear Information System (INIS)

    Liebetruth, R.

    1984-01-01

    In an extension of the utility of rotary scan tomographic x-ray apparatus, the apparatus is locked in a fixed angular relationship and the patient support is automatically advanced in small longitudinal increments relative to the angularly fixed scanner, the scanner being pulsed in synchronism with the longitudinal steps to produce successive sets of transmittance readings defining a radiographic shadow image having a substantial longitudinal extent. The stored sets of readings may be reproduced on a conventional television display unit. Advantageously, the scanner may present a fan-type beam which in a fixed angular relationship to the patient still scans a substantial portion of the patient cross section, the x-ray source or sources being pulsed at successive longitudinal positions of the patient relative to the scanning apparatus, and the successive sets of readings being utilized for on line display of a shadow radiograph covering the desired longitudinal extent

  2. Computed tomographic scan of amenorrhea-galactorrhea syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Yutaka; Inoue, Yuichi; Takemoto, Kazumasa; Oda, Atsuo; Yahata, Satoshi (Osaka City Univ. (Japan). Faculty of Medicine)

    1984-05-01

    Thin (2 mm) section CT scans of a pituitary gland of 30 amenorrhea-galactorrhea patients were reviewed. Eleven out of 30 patients were diagnosed as having a pituitary adenoma (tumor group); nine prolactionomas were verified by surgery. Tumor density compared with normal pituitary gland was low in five, low-mixed in three and isodense in four. The upper margin of a prolactinoma was convexed upward in seven, flat in two and concaved downward in two. Pituitary stalk was deviated in two and not visualized in four. Serum prolactine level (PRL) was more than 130 ng/ml in tumor group. There was a positive correlation between the size of a prolactinoma and PRL. Four prolactinomas invaded the cavernous sinus; three of them showed higher PRL than 1,000 ng/ml.

  3. Computed tomographic scan of amenorrhea-galactorrhea syndrome

    International Nuclear Information System (INIS)

    Nemoto, Yutaka; Inoue, Yuichi; Takemoto, Kazumasa; Oda, Atsuo; Yahata, Satoshi

    1984-01-01

    Thin (2 mm) section CT scans of a pituitary gland of 30 amenorrhea-galactorrhea patients were reviewed. Eleven out of 30 patients were diagnosed to have a pituitary adenoma (tumor group); nine prolactionomas were verified by surgery. Tumor density compared with normal pituitary gland was low in five, low-mixed in three and isodense in four. The upper margin of a prolactinoma was convexed upward in seven, flat in two and concaved downward in two. Pituitary stalk was deviated in two and not visualized in four. Serum prolactine level (PRL) was more than 130 ng/ml in tumor group. There was a positive correlation between the size of a prolactinoma and PRL. Four prolactinomas invaded the cavernous sinus; three of them showed higher PRL than 1,000 ng/ml. (author)

  4. Computerized adaptive testing item selection in computerized adaptive learning systems

    NARCIS (Netherlands)

    Eggen, Theodorus Johannes Hendrikus Maria; Eggen, T.J.H.M.; Veldkamp, B.P.

    2012-01-01

    Item selection methods traditionally developed for computerized adaptive testing (CAT) are explored for their usefulness in item-based computerized adaptive learning (CAL) systems. While in CAT Fisher information-based selection is optimal, for recovering learning populations in CAL systems item

  5. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  6. Radiographic and computed tomographic demonstration of pseudotumor cerebri due to rapid weight gain in a child with pelvic rhabdomyosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Berdon, W.E.; Barker, D.H.; Barash, F.S.

    1982-06-01

    Rapid weight gain in a malnourished child can be associated with suture diastasis in the pattern of pseudotumor cerebri; this has been previously reported in deprivational dwarfism and cystic fibrosis. In a child with pelvic rhabdomyosarcoma, skull radiographs and cranial computed tomographic (CT) scans were available prior to a period of rapid weight gain induced by hyperalimentation. Suture diastasis developed and repeat CT scans showed this to be accompanied by smaller ventricles.

  7. Radiographic and computed tomographic demonstration of pseudotumor cerebri due to rapid weight gain in a child with pelvic rhabdomyosarcoma

    International Nuclear Information System (INIS)

    Berdon, W.E.; Barker, D.H.; Barash, F.S.

    1982-01-01

    Rapid weight gain in a malnourished child can be associated with suture diastasis in the pattern of pseudotumor cerebri; this has been previously reported in deprivational dwarfism and cystic fibrosis. In a child with pelvic rhabdomyosarcoma, skull radiographs and cranial computed tomographic (CT) scans were available prior to a period of rapid weight gain induced by hyperalimentation. Suture diastasis developed and repeat CT scans showed this to be accompanied by smaller ventricles

  8. The research of clinical application of computed tomographic virtual gastroscopy

    International Nuclear Information System (INIS)

    Zhang Lei; Pan Zhenyu; Zhai Xiaoli; Gu Hua; Wang Yajie; Ding Yi; Wang Li; Liang Ying; Zhai Renyou

    2000-01-01

    Objective: To investigate the values, methods and findings of computed tomographic virtual gastroscopy (CTVG). Methods: Sixty-nine patients underwent the examination of spiral CT after charged air into stomachs in different cubage. The CT scan conditions were collimating width 3 mm, pitch 1.2 - 2.5, scanning speed 0.8 s/360 degree, the raw data of CT volume scan was reconstructed in overlapping rate 33% - 67%. Then the images of CTVG were built using navigator software (GE AG, USA). Results: The accuracy, sensitivity, and specificity of CTVG were 92.8%, 96.4%, and 78.6%, respectively. CTVG corresponded well with fibrous gastroscopy and specimens in demonstrating the gastric lesions. CTVG was provided with the ability of revealing the tiny lesions of chronic atrophic gastritis, chronic erosive gastritis, chronic proliferative gastritis, and acute hemorrhagic gastritis in some degree. The high quality imaging of CTVG could be obtained in condition of collimating width 3 mm, pitch 1.2 - 1.5, overlapping 50% - 67%, well hold-breath, gastric cubage in full and feasible scan positions. Conclusion: CTVG is a rising means of gastric examination and has great value in clinic applications

  9. Longitudinal and transverse digital image reconstruction with a tomographic scanner

    International Nuclear Information System (INIS)

    Pickens, D.R.; Price, R.R.; Erickson, J.J.; Patton, J.A.; Partain, C.L.; Rollo, F.D.

    1981-01-01

    A Siemens Gammasonics PHO/CON-192 Multiplane Imager is interfaced to a digital computer for the purpose of performing tomographic reconstructions from the data collected during a single scan. Data from the two moving gamma cameras as well as camera position information are sent to the computer by an interface designed in the authors' laboratory. Backprojection reconstruction is implemented by the computer. Longitudinal images in whole-body format as well as smaller formats are reconstructed for up to six planes simultaneously from the list mode data. Transverse reconstructions are demonstrated for 201 T1 myocardial scans. Post-reconstruction deconvolution processing to remove the blur artifact (characteristic of focal plane tomography) is applied to a multiplane phantom. Digital data acquisition of data and reconstruction of images are practical, and can extend the usefulness of the machine when compared with the film output (author)

  10. Dual scan CT image recovery from truncated projections

    Science.gov (United States)

    Sarkar, Shubhabrata; Wahi, Pankaj; Munshi, Prabhat

    2017-12-01

    There are computerized tomography (CT) scanners available commercially for imaging small objects and they are often categorized as mini-CT X-ray machines. One major limitation of these machines is their inability to scan large objects with good image quality because of the truncation of projection data. An algorithm is proposed in this work which enables such machines to scan large objects while maintaining the quality of the recovered image.

  11. Low-dose computed tomographic imaging in orbital trauma

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, A.; Whitehouse, R.W. (Manchester Univ. (United Kingdom). Dept. of Diagnostic Radiology)

    1993-08-01

    The authors review findings in 75 computed tomographic (CT) examinations of 66 patients with orbital trauma who were imaged using a low-radiation-dose CT technique. Imaging was performed using a dynamic scan mode and exposure factors of 120 kVp and 80 mAs resulting in a skin dose of 11 mGy with an effective dose-equivalent of 0.22 mSv. Image quality was diagnostic in all cases and excellent in 73 examinations. Soft-tissue abnormalities within the orbit including muscle adhesions were well demonstrated both on primary axial and reconstructed multiplanar images. The benefits of multiplanar reconstructions are stressed and the contribution of soft-tissue injuries to symptomatic diplopia examined. (author).

  12. Scanning apparatus and method

    International Nuclear Information System (INIS)

    Brunnett, C.J.

    1980-01-01

    A novel method is described for processing the analogue signals from the photomultiplier tubes in a tomographic X-ray scanner. The system produces a series of pulses whose instantaneous frequency depends on the detected intensity of the X-radiation. A timer unit is used to determine the segment scan intervals and also to deduce the average radiation intensity detected during this interval. The overall system is claimed to possess the advantageous properties of low time delay, wide bandwidth and relative low cost. (U.K.)

  13. Simulation of Tomographic Reconstruction of Magnetosphere Plasma Distribution By Multi-spacecraft Systems.

    Science.gov (United States)

    Kunitsyn, V.; Nesterov, I.; Andreeva, E.; Zelenyi, L.; Veselov, M.; Galperin, Y.; Buchner, J.

    A satellite radiotomography method for electron density distributions was recently proposed for closely-space multi-spacecraft group of high-altitude satellites to study the physics of reconnection process. The original idea of the ROY project is to use a constellation of spacecrafts (one main and several sub-satellites) in order to carry out closely-spaced multipoint measurements and 2D tomographic reconstruction of elec- tron density in the space between the main satellite and the subsatellites. The distances between the satellites were chosen to vary from dozens to few hundreds of kilometers. The easiest data interpretation is achieved when the subsatellites are placed along the plasma streamline. Then, whenever a plasma density irregularity moves between the main satellite and the subsatellites it will be scanned in different directions and we can get 2D distribution of plasma using these projections. However in general sub- satellites are not placed exactly along the plasma streamline. The method of plasma velocity determination relative to multi-spacecraft systems is considered. Possibilities of 3D tomographic imaging using multi-spacecraft systems are analyzed. The model- ing has shown that efficient scheme for 3D tomographic imaging would be to place spacecrafts in different planes so that the angle between the planes would make not more then ten degrees. Work is supported by INTAS PROJECT 2000-465.

  14. Computed tomographic spectrum of intracranial mycosis: correlation with histopathology

    International Nuclear Information System (INIS)

    Whelan, M.A.; Stern, J.; deNapoli, R.A.

    1981-01-01

    Four cases of intracerebral fungal infection are reviewed. The clinical course is outlined, and the computed tomographic (CT) characteristics are analyzed in light of known pathological data. The CT appearance of intracranial mycosis is dependent on the type of fungus as well as the dominant infecting form, i.e., yeast or hyphae. The hyphal form leads predominantly to a CT pattern consistent with vascular occlusion and secondary abscess formation; the yeast form generally results in noncaseating granulomas, which appear on CT scan as nodular enhancing lesions. If the patient survives the acute infective process, these fungal lesions undergo a prolonged subacute phase, and may eventually calcify

  15. Development of x-ray computed tomographic scanner for iron and steel

    International Nuclear Information System (INIS)

    Taguchi, Isamu; Nakamura, Shigeo.

    1985-01-01

    X-ray computed tomography is extensively used in medicine, but has rarely been applied to non-medical purposes. Steel specimens pose particularly difficult problems-very poor transmission of X-rays and the need for high resolving capability. There has thus been no effective tomographic method of examining steel specimens. Due to the growing need for non-destructive, non-contact methods for observing and analyzing the internal conditions of steel microscopically, however, we have developed an X-ray Computed Tomographic Scanner for Steel (CTS) system, specifically for examination of steel specimens. Its major specifications and functions are as follows. Type: the second-generation CT, 8-channels, Scanning method: 6 0 revolution, 30-times traversing, Slice width: 0.5 mm, Resolving capability: 0.25 x 0.25 mm, X-ray source: 420 kV, 3 mA, X-ray detector: BGO scintillator, Standard specimen shape: 50 mm dia., 100 mm high, Measuring time: 10.5 min. Porosity of a stainless steel (SUS 304) bloom was examined three-dimensionally by the CTS system. Corrosion procedure of a steel slab was also examined. (author)

  16. Tomographical properties of uniformly redundant arrays

    International Nuclear Information System (INIS)

    Cannon, T.M.; Fenimore, E.E.

    1978-01-01

    Recent work in coded aperture imaging has shown that the uniformly redundant array (URA) can image distant planar radioactive sources with no artifacts. The performance of two URA apertures when used in a close-up tomographic imaging system is investigated. It is shown that a URA based on m sequences is superior to one based on quadratic residues. The m sequence array not only produces less obnoxious artifacts in tomographic imaging, but is also more resilient to some described detrimental effects of close-up imaging. It is shown that in spite of these close-up effects, tomographic depth resolution increases as the source is moved closer to the detector

  17. Computerized axial tomography of the chest for visualization of ''absent'' pulmonary arteries

    International Nuclear Information System (INIS)

    Sondheimer, H.M.; Oliphant, M.; Schneider, B.; Kavey, R.E.W.; Blackman, M.S.; Parker, F.B. Jr.

    1982-01-01

    To expand the search for central pulmonary arteries in six patients with absence of cardiac-pulmonary continuity, computerized axial tomography (CAT) of the chest was performed. The CAT scans were compared with previous arteriograms and pulmonary vein wedge angiograms. Three patients with type IV truncus arteriosus were studied, and none had a central, right or left pulmonary artery on CAT scan. However, two patients with tetralogy of Fallot with pulmonary atresia and a patent ductus arteriosus to the right lung demonstrated the presence of a left pulmonary artery. In addition, one child with truncus arteriosus with ''absent'' left pulmonary artery demonstrated a left pulmonary artery on the CAT scan. The CAT scan may therefore enhance our ability to search for disconnected pulmonary arteries in children with complex cyanotic congenital heart disease

  18. Computed tomographic findings of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Jo, In Su; Jong, Woo Yung; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki

    1987-01-01

    With Development of Computed Tomography, detection of the Hepatocellular Carcinoma are easily performed and frequently used in the world. During 15 months, from December 1985 to February 1987, 59 patients with hepatocellular carcinoma were evaluated with computed tomography in department of radiology at Wallace Memorial Baptist Hospital. The results were as follow: 1. The most prevalent age group was 5th to 7th decades, male to female ratio was 4.9:1. 2. Classification with incidence of computed tomographic appearance of the hepatocellular carcinoma were solitary type 28 cases (48%), multinodular type 24 cases (40%), and diffuse type 7 cases (12%), Association with liver cirrhosis was noted in 22 cases (38%). 3. Inhomogenous internal consistency of hepatocellular carcinoma due to central necrosis were 35 cases (60%). Portal vein invasion by hepatocellular carcinoma was noted in 15 cases (25%), and particularly most common in diffuse type 4 cases (55%). 4. On precontrast scan, all hepatocellular carcinoma were seen as area of low density except for 3 cases(0.5%) of near isodensity which turned out to be remarkable low density on postcontrast scan. 5. In solitary type, posterior segment of right lobe was most common site of involvement 12 cases (43%). In diffuse type, bilobar involvement was most common, 6 cases (85%)

  19. Spontaneous Intracerebral Hemorrhage: Computed Tomographic Characteristics and Outcome

    Directory of Open Access Journals (Sweden)

    Aimara de la Caridad Vergara Santos

    2015-12-01

    Full Text Available Background: strokes are the third leading cause of death among adults and 10-15 % of them are due to spontaneous intracerebral hemorrhage. Objective: to characterize spontaneous intracerebral hemorrhage through computed tomography scan and its outcome. Methods: a case series study was conducted comprising patients diagnosed with spontaneous intracerebral hemorrhage admitted to the Arnaldo Milián Castro Provincial University Hospital in Villa Clara from January 2009 to January 2010. Tomographic variables of interest were derived from evaluation of spontaneous intracerebral hematomas. Results: fifty-nine cases of spontaneous intracerebral hemorrhage were studied, 23 were located in lobar regions, 4 had severe midline shift, and 2 showed volume greater than 80 ml. Eight out of eleven with extension into the ventricular system had an unfavorable outcome. Among those with thalamic hemorrhage, patients with diameter larger than 4cm and extension into the ventricular system died. Patients with putaminal hemorrhage larger than 4 cm and posterior fossa hematoma with hydrocephalus had a poor outcome, as well as most individuals (55 with other mass effects. Most lobar hematomas (14 out of 23 had a satisfactory outcome, unlike cerebellar and brainstem hematomas. Conclusions: tomographic variables that had a negative impact on the outcome were: volume greater than 80 ml, severe midline shift, diameter larger than 4 cm, extension into the ventricular system, hydrocephalus, other signs of mass effect and brainstem location.

  20. Computed tomographic analysis of temporal maxillary stability and pterygomaxillary generate formation following pediatric Le Fort III distraction advancement.

    Science.gov (United States)

    Hopper, Richard A; Sandercoe, Gavin; Woo, Albert; Watts, Robyn; Kelley, Patrick; Ettinger, Russell E; Saltzman, Babette

    2010-11-01

    Le Fort III distraction requires generation of bone in the pterygomaxillary region. The authors performed retrospective digital analysis on temporal fine-cut computed tomographic images to quantify both radiographic evidence of pterygomaxillary region bone formation and relative maxillary stability. Fifteen patients with syndromic midface hypoplasia were included in the study. The average age of the patients was 8.7 years; 11 had either Crouzon or Apert syndrome. The average displacement of the maxilla during distraction was 16.2 mm (range, 7 to 31 mm). Digital analysis was performed on fine-cut computed tomographic scans before surgery, at device removal, and at annual follow-up. Seven patients also had mid-consolidation computed tomographic scans. Relative maxillary stability and density of radiographic bone in the pterygomaxillary region were calculated between each scan. There was no evidence of clinically significant maxillary relapse, rotation, or growth between the end of consolidation and 1-year follow-up, other than a relatively small 2-mm subnasal maxillary vertical growth. There was an average radiographic ossification of 0.5 mm/mm advancement at the time of device removal, with a 25th percentile value of 0.3 mm/mm. The time during consolidation that each patient reached the 25th percentile of pterygomaxillary region bone density observed in this series of clinically stable advancements ranged from 1.3 to 9.8 weeks (average, 3.7 weeks). There was high variability in the amount of bone formed in the pterygomaxillary region associated with clinical stability of the advanced Le Fort III segment. These data suggest that a subsection of patients generate the minimal amount of pterygomaxillary region bone formation associated with advancement stability as early as 4 weeks into consolidation.

  1. Diffuse nesidioblastosis diagnosed on a Ga-68 DOTATATE positron emission tomography/computerized tomography

    International Nuclear Information System (INIS)

    Arun, Sasikumar; Mittal, Bhagwant Rai; Shukla, Jaya; Bhattacharya, Anish; Kumar, Praveen

    2013-01-01

    The authors describe a 50 days old pre-term infant with persistent hyperinsulinemic hypoglycemia of infancy in whom 68 Ga DOTATATE positron emission tomography/computerized tomography scan showed diffusely increased tracer uptake in the entire pancreas with no abnormal tracer uptake anywhere else in the body, suggestive of a diffuse variant of nesidioblastosis. (author)

  2. Computerized tomographic evaluations of 33 consecutive cases of craniopharyngiomas

    International Nuclear Information System (INIS)

    Nagasawa, Shiro; Takeuchi, Juji; Yamashita, Junkoh; Handa, Hajime

    1983-01-01

    Although craniopharyngiomas are widely known to exhibit three basic CT characteristics; calcification, cyst(s) and contrast enhancement (CE), several cases with atypical CT manifestations have been reported lately. These atypical manifestations can be classified into unusual extensions of the tumors, high dense cyst and marked homogeneous CE. The CT scans obtained in our recent series of 33 craniopharyngiomas were evaluated to analyze tumoral extensions, cyst density and CE. Cystic tumors were much more frequent than solid tumors (Table 1); 13 cases (39%) were exclusively cystic, 15 cases (45%) equally cystic and solid, and 5 case (15%) solid. Calcifications were present in 80 % in children and 39% in adults. Unusual extensions were noted in 7 cases (Fig. 2,3,4); anteriorly to the frontal fossa (5 cases, 15 %), laterally to the temporal fossa (1 case, 3%) and posteriorly to the posterior fossa (1 case, 3%). All these tumors were either pure cystic or equally cystic and solid. Cystic portions were detected in the tumors of 28 cases (Table 2). Although the majority of the cystic portions (22 cases, 79%) were low density, iso-dense cysts were observed in 6 cases (21%). Out of 20 cases exhibiting solid portions in the tumors, high density areas (calcified masses) were detected in 3 cases and mixed density areas in 17 cases (Table 3). While these 17 cases showed CE, marked homogeneous CE were noted in 5 cases (29%)

  3. Computer tomographic diagnosis of echinococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Haertel, M.; Fretz, C.; Fuchs, W.A.

    1980-08-01

    The computer tomographic appearances and differential diagnosis in 22 patients with echinococcosis are described; of these, twelve were of the cystic and ten of the alveolar type. The computer tomographic appearances are characterised by the presence of daughter cysts (66%) within the sharply demarkated parasitic cyst of water density. In the absence of daughter cysts, a definite aetiological diagnosis cannot be made, although there is a tendency to clasification of the occassionally multiple echinococcus cysts. The computer tomographic appearances of advanced alveolar echinococcosis are characterised by partial collequative necrosis, with clacification around the necrotic areas (90%). The absence of CT evidence of partial necrosis and calsification of the pseudotumour makes it difficult to establish a specific diagnosis. The conclusive and non-invasive character of the procedure and its reproducibility makes computer tomography the method of choice for the diagnosis and follow-up of echinococcosis.

  4. Nano-tomography of porous geological materials using focused ion beam-scanning electron microscopy

    NARCIS (Netherlands)

    Liu, Yang; King, Helen E.; van Huis, Marijn A.; Drury, Martyn R.; Plümper, Oliver

    2016-01-01

    Tomographic analysis using focused ion beam-scanning electron microscopy (FIB-SEM) provides three-dimensional information about solid materials with a resolution of a few nanometres and thus bridges the gap between X-ray and transmission electron microscopic tomography techniques. This contribution

  5. Integrating bar-code devices with computerized MC and A systems

    International Nuclear Information System (INIS)

    Anderson, L.K.; Boor, M.G.; Hurford, J.M.

    1998-01-01

    Over the past seven years, Los Alamos National Laboratory developed several generations of computerized nuclear materials control and accountability (MC and A) systems for tracking and reporting the storage, movement, and management of nuclear materials at domestic and international facilities. During the same period, Oak Ridge National Laboratory was involved with automated data acquisition (ADA) equipment, including installation of numerous bar-code scanning stations at various facilities to serve as input devices to computerized systems. Bar-code readers, as well as other ADA devices, reduce input errors, provide faster input, and allow the capture of data in remote areas where workstations do not exist. Los Alamos National Laboratory and Oak Ridge National Laboratory teamed together to implement the integration of bar-code hardware technology with computerized MC and A systems. With the expertise of both sites, the two technologies were successfully merged with little difficulty. Bar-code input is now available with several functions of the MC and A systems: material movements within material balance areas (MBAs), material movements between MBAs, and physical inventory verification. This paper describes the various components required for the integration of these MC and A systems with the installed bar-code reader devices and the future directions for these technologies

  6. Influence of antibacterial therapy on bone scan indices at foot inflammation in diabetes mellitus accompanied by diabetic foot syndrome

    International Nuclear Information System (INIS)

    Slavnov, V.M.; Bolgars'ka, S.V.; Taran, E.V.; Markov, V.V.

    2004-01-01

    The influence of antibacterial therapy on bone scan indices at foot inflammation in patients with diabetes mellitus (DM) accompanied by diabetic foot syndrome was studied. Bone scan was performed using scintillation tomographic gamma-camera hours after intravenous injection of 99m Tc-methylene diphosphonate

  7. Dosimetry of computerized tomography in the evaluation of hip dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Guyer, B.; Bassano, D.A.; Levinsohn, E.M.; Smith, D.S.; Cady, R.B.

    1984-07-01

    The usefulness of computerized tomography (CT) in the assessment of hip dysplasia has recently been given attention in the literature and concern regarding radiation dose has been raised. This study was undertaken to measure the radiation dose, both in and out of plaster, for plain films, arthrography, tomography, and CT. A method is suggested to reduce dosage by 80% without compromising diagnostic information. Our experience with 25 scans of patients aged 4 months to 39 years is presented.

  8. Experimental and theoretical analysis for improved microscope design of optical projection tomographic microscopy.

    Science.gov (United States)

    Coe, Ryan L; Seibel, Eric J

    2013-09-01

    We present theoretical and experimental results of axial displacement of objects relative to a fixed condenser focal plane (FP) in optical projection tomographic microscopy (OPTM). OPTM produces three-dimensional, reconstructed images of single cells from two-dimensional projections. The cell rotates in a microcapillary to acquire projections from different perspectives where the objective FP is scanned through the cell while the condenser FP remains fixed at the center of the microcapillary. This work uses a combination of experimental and theoretical methods to improve the OPTM instrument design.

  9. Pathogenesis of traumatic intracerebral hematoma with a sequential study of computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ohmori, H; Miyazaki, S; Munekata, K; Fukushima, H [Hitachi General Hospital, Hitachi, Ibaraki (Japan); Shohji, A

    1981-04-01

    A sequential study with computerized tomography (CT scan) of two cases of traumatic intracerebral hematoma is reported. Case 1 was a 69-year-old man who had a head injury. The initial CT scan, taken 1 hour after his injury, showed a left temporal salt-and-pepper appearance, which proved to be a cerebral contusion. The CT scan 4.5 hours after his injury showed a left temporal high density area instead. An operation was performed, and a massive intracerebral hematoma was observed. Case 2 was a 61-year-old man who was also admitted because of a head injury. The initial CT scan, taken 1 hour after his injury, revealed several bifrontal intracerebral hemorrhagic spots in the low-density areas, suggesting contusion. A secondary CT scan (23 hours) demonstrated that the traumatic intracerebral hematoma had developed into a posttraumatic cerebral contusion. The operation disclosed a hematoma surrounded by contusion. These cases prove that traumatic intracerebral hematoma is often caused by cerebral contusion.

  10. Precision tomographic analysis of reactor fuels

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research.

  11. Precision tomographic analysis of reactor fuels

    International Nuclear Information System (INIS)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research

  12. Use of radiologic modalities in coccidioidal meningitis

    International Nuclear Information System (INIS)

    Stadalnik, R.C.; Goldstein, E.; Hoeprich, P.D.; McGahan, J.P.

    1981-01-01

    The diagnostic utility of pentetate indium trisodium CSF studies, technetium Tc 99m brain scans, and computerized tomographic (CT) scans was evaluated in eight patients in whom coccidioidal meningitis developed following a dust storm in the Central Valley of California. The 111In flow studies and the CT scans demonstrated hydrocephalus in five patients with clinical findings suggesting this complication. Ventriculitis has not previously been diagnosed before death in patients with coccidioidal meningitis; however, it was demonstrated in two patients by the technetium Tc 99m brain scan. The finding that communicating hydrocephalus occurs early in meningitis and interferes with CSF flow into infected basilar regions has important therapeutic implications in that antifungal agents injected into the lumbar subarachnoid space may not reach these regions

  13. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  14. Computerized hydraulic scanning system for quantitative non destructive examination

    International Nuclear Information System (INIS)

    Gundtoft, H.E.

    1982-01-01

    A hydraulic scanning system with five degrees of freedom is described. It is primarily designed as a universal system for fast and accurate ultrasonic inspection of materials for their internal variation in properties. The whole system is controlled by a minicomputer which also is used for evaluating and presenting of the results of the inspection. (author)

  15. Tomographic visualization of stress corrosion cracks in tubing

    International Nuclear Information System (INIS)

    Morris, R.A.; Kruger, R.P.; Wecksung, G.W.

    1979-06-01

    A feasibility study was conducted to determine the possibility of detecting and sizing cracks in reactor cooling water tubes using tomographic techniques. Due to time and financial constraints, only one tomographic reconstruction using the best technique available was made. The results indicate that tomographic reconstructions can, in fact, detect cracks in the tubing and might possibly be capable of measuring the depth of the cracks. Limits of detectability and sensitivity have not been determined but should be investigated in any future work

  16. Diagnostic Yield of Transbronchial Biopsy in Comparison to High Resolution Computerized Tomography in Sarcoidosis Cases

    Science.gov (United States)

    Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan

    2018-04-25

    This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License

  17. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  18. Tomographic method and apparatus

    International Nuclear Information System (INIS)

    Moore, R.M.

    1981-01-01

    A tomographic x-ray machine has a camera and film-plane section which move about a primary axis for imaging a selected cross-section of an anatomical member onto the film. A ''scout image'' of the member is taken at right angles to the plane of the desired cross-section to indicate the cross-section's angle with respect to the primary axis. The film plane is then located at the same angle with respect to a film cassette axis as the selected cross-section makes with the primary axis. The film plane and the cross-section are then maintained in parallel planes throughout motion of the camera and film plane during tomographic radiography. (author)

  19. Computed tomographic (CT) scans in cerebral palsy (CP)

    International Nuclear Information System (INIS)

    Kolawole, T.M.; Patel, P.J.; Mahdi, A.H.

    1989-01-01

    The CT findings in 120 cerebral palsied children are analysed. The 72.5% positive findings are correlated with the clinical types, as well as the aetiological basis for the cerebral palsy. The spastic type, 83.3% of the total number of children, had the highest positive findings. The yield was increased in children with seizures (91.3%) and those in the postnatal group (90%), as well as those with birth trauma and neonatal asphyxia (94%). The findings were those of atrophy in 30.8%, hydrocephalus, in 10%, infarct in 11.6%, porencephaly in 8.3% and others. The atropic changes and their patterns are explained. Treatable lesions, such as tumour, hydrocephalus, subdural haematoma, porencephaly and hygroma were identified in 22.5% of cases. It is concluded that CT scan is definitely efficacious in the management of cerebral palsied children. (orig.)

  20. Chronic subdural hematoma fluid and its computerized tomographic density

    International Nuclear Information System (INIS)

    Masuzawa, Hideaki; Sato, Jinichi; Kamitani, Hiroshi; Yamashita, Midori

    1983-01-01

    Laboratory and in vivo CT analysis were performed on 19 chronic subdural hematomas and five subdural hygromas. In these 25 hematoma samples, red blood cells (RBC), hematocrit, and hemoglobin (Hgb) varied greatly, though, these values correlated well with the CT densities. Plasma protein content was fairly constant with an average of 7.1+-0.8g/dl. There were four hematoma samples with RBC of less than 20x10 4 μl or Hgb of less than 2.0g/dl. Their CT values ranged between 18 and 23 H.U., which were considered close to the in vivo serum level CT density. Five hygroma fluid showed no RBC and very little protein content of less than 0.4g/dl. CT density ranged between -2 and 13 H.U. The edge effect of the skull was experimentally studied using a phantom skull filled with water. This revealed a remarkable overshoot of the CT values within ten pixels from the inner wall of the skull. Visual observation of the original CT pictures revealed four low density hematomas and seven mixed density ones. When compared to the density of the ventricular cavity, all of the low density hematomas and the supernatant part of the mixed density ones were clearly higher in density. All five hygromas appeared CSF dense or lower. In conclusion, because of the edge effect by the skull, thin subdural fluids could not be diagnosed by CT alone. Thick subdural fluids could be differentiated as either hematoma or hygroma by their CT densities. Subdural hematomas had in vivo CT densities of at least serum level or approximately 20 H.U., while subdural hygromas had densities close to CSF. These characteristics were best appreciated by visual observation of the CT scan films. (J.P.N.)

  1. Apparatus for stereotactic surgery

    International Nuclear Information System (INIS)

    Koslow, M.A.M.

    1982-01-01

    Apparatus for stereotactic surgery consisting of a probe and a computerized tomographic scanning system is described. The scanning system comprises a display and means for reconstructing cross-sectional images on the display using data from partial circumferential scans of source and detectors. It operates on the data with an algorithm that provides the difference between the local values of the linear attenuation coefficient and average of these values within a circle centered at each reconstruction point. The scanning system includes a means of maintaining the frames of reference of the probe and scanning system rigid with respect to one another. The position of the probe, which may be a cryogenic probe, with respect to the actual anatomical structure of the body, particularly a human head, may thus be viewed by the surgeon. (author)

  2. Body composition in chemotherapy: the promising role of CT scans.

    Science.gov (United States)

    Prado, Carla M M

    2013-09-01

    Reducing cancer-treatment toxicity was a largely ignored research agenda, which is now emerging as an active area of investigation. Studies of human body composition using computerized tomography scans have provided proof-of-concept that variability in drug disposition and toxicity profiles may be partially explained by different features in body composition. Collectively, studies suggest that skeletal muscle depletion (regardless of body weight) is an independent predictor of severe toxicity, affecting cancer treatment and its outcomes. Although precise mechanisms are unknown, pharmacokinetic parameters such as variations in volume of distribution and increased drug exposure may explain such findings. Computerized tomography scans are readily available in clinical databases of diagnostic images and provide feasible, reliable, and highly differentiated measurements of body composition. These images should be used to optimize screening and management of patients in order to prevent severe toxicity, and to improve the efficacy and cost-efficiency of chemotherapy treatments.

  3. Reproducibility of temporomandibular joint tomography. Influence of shifted X-ray beam and tomographic focal plane on reproducibility

    International Nuclear Information System (INIS)

    Saito, Masashi

    1999-01-01

    Proper tomographic focal plane and x-ray beam direction are the most important factors to obtain accurate images of the temporomandibular joint (TMJ). In this study, to clarify the magnitude of effect of these two factors on the image quality. We evaluated the reproducibility of tomograms by measuring the distortion when the x-ray beam was shifted from the correct center of the object. The effects of the deviation of the tomographic focal plane on image quality were evaluated by the MTF (Modulation Transfer Function). Two types of tomograms, one the plane type, the other the rotational type were used in this study. A TMJ model was made from Teflon for the purpose of evaluation by shifting the x-ray beam. The x-ray images were obtained by tilting the model from 0 to 10 degrees 2-degree increments. These x-ray images were processed for computer image analysis, and then the distance between condyle and the joint space was measured. To evaluate the influence of the shifted tomographic focal plane on image sharpness, the x-ray images from each setting were analyzed by MTF. To obtain the MTF, ''knife-edge'' made from Pb was used. The images were scanned with a microdensitometer at the central focal plane, and 0, 0.5, 1 mm away respectively. The density curves were analyzed by Fourier analysis and the MTF was calculated. The reproducibility of images became worse by shifting the x-ray beam. This tendency was similar for both tomograms. Object characteristics such as anterior and posterior portion of the joint space affected the deterioration of reproducibility of the tomography. The deviation of the tomographic focal plane also decreased the reproducibility of the x-ray images. The rotational type showed a better MTF, but it became seriously unfavorable with slight changes of the tomographic focal plane. Contrarily, the plane type showed a lower MTF, but the image was stable with shifting of the tomographic focal plane. (author)

  4. Tomographic extreme-ultraviolet spectrographs: TESS.

    Science.gov (United States)

    Cotton, D M; Stephan, A; Cook, T; Vickers, J; Taylor, V; Chakrabarti, S

    2000-08-01

    We describe the system of Tomographic Extreme Ultraviolet (EUV) SpectrographS (TESS) that are the primary instruments for the Tomographic Experiment using Radiative Recombinative Ionospheric EUV and Radio Sources (TERRIERS) satellite. The spectrographs were designed to make high-sensitivity {80 counts/s)/Rayleigh [one Rayleigh is equivalent to 10(6) photons/(4pi str cm(2)s)}, line-of-sight measurements of the oi 135.6- and 91.1-nm emissions suitable for tomographic inversion. The system consists of five spectrographs, four identical nightglow instruments (for redundancy and added sensitivity), and one instrument with a smaller aperture to reduce sensitivity and increase spectral resolution for daytime operation. Each instrument has a bandpass of 80-140 nm with approximately 2- and 1-nm resolution for the night and day instruments, respectively. They utilize microchannel-plate-based two-dimensional imaging detectors with wedge-and-strip anode readouts. The instruments were designed, fabricated, and calibrated at Boston University, and the TERRIERS satellite was launched on 18 May 1999 from Vandenberg Air Force Base, California.

  5. Precision of quantum tomographic detection of radiation

    Energy Technology Data Exchange (ETDEWEB)

    D' Ariano, G.M. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy) Istituto Nazionale di Fisica Nucleare, Sezione di Pavia, Via A. Bassi 6, I-27100, Pavia (Italy)); Macchiavello, Chiara (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy)); Paris, M.G.A. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy))

    1994-11-21

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  6. Precision of quantum tomographic detection of radiation

    International Nuclear Information System (INIS)

    D'Ariano, G.M.; Macchiavello, Chiara; Paris, M.G.A.

    1994-01-01

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  7. Implementation of 3D tomographic visualisation through planar ICT data from experimental gamma-ray tomographic system

    International Nuclear Information System (INIS)

    Umesh Kumar; Singh, Gursharan; Ravindran, V.R.

    2001-01-01

    Industrial Computed Tomography (ICT) is one of the latest methods of non-destructive testing and examination. Different prototypes of Computed Industrial Tomographic Imaging System (CITIS) have been developed and experimental data have been generated in Isotope Applications Division. The experimental gamma-rays based tomographic imaging system comprises of beam generator containing approx. 220 GBq (6 Curies) of 137 Cs, a single NaI(Tl) -PMT integral assembly in a thick shielding and associated electronics, stepper motor controlled mechanical manipulator, collimators and required software. CITIS data is normally acquired in one orientation of the sample. It may be sometimes required to view a tomographic plane in a different orientation. Also, 3D visualization may be required with the available 2D data set. All these can be achieved by processing the available data. We have customized some of the routines for this purpose provided IDL (Integrated Data Language) package to suit our requirements. The present paper discusses methodology adopted for this purpose with an illustrative example. (author)

  8. Computer tomographs

    International Nuclear Information System (INIS)

    Niedzwiedzki, M.

    1982-01-01

    Physical foundations and the developments in the transmission and emission computer tomography are presented. On the basis of the available literature and private communications a comparison is made of the various transmission tomographs. A new technique of computer emission tomography ECT, unknown in Poland, is described. The evaluation of two methods of ECT, namely those of positron and single photon emission tomography is made. (author)

  9. Computerizing primary schools in rural kenya

    DEFF Research Database (Denmark)

    Ogembo, J.G.; Ngugi, B.; Pelowski, Matthew John

    2012-01-01

    questions surrounding this endeavour. Specifically: 1.) what problems do rural schools actually want to solve with computerization; 2.) is computerization the most important priority for rural schools; 3.) are schools ready, in terms of infrastructure, for a computer in the classroom; or 4.) might...... and protective roofing -posing severe challenges to the outstanding conception of computerization. We consider these results and make recommendations for better adapting programs for computer introduction, and also suggest the use of new innovative devices, such as cell phones, which might already have overcome......This paper investigates the outstanding challenges facing primary schools' computerization in rural Kenya. Computerization of schools is often envisaged as a 'magic', or at least a particularly efficient, solution to many of the problems that developing countries face in improving primary school...

  10. Carotid ultrasonographic and brain computerized tomographic findings in patients with vascular ocular syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, Toshihiko; Matsushima, Chikage; Shimizu, Souichirou; Takasaki, Masaru; Iwasaki, Takuya; Usui, Masahiko [Tokyo Medical Coll. (Japan)

    2002-02-01

    To clarify the characteristics of cerebrovascular lesions in subtypes of vascular ocular syndrome, including amaurosis fugax (AF), retinal artery occlusion (RAO), and retinal vein occlusion (RVO), 93 patients with vascular ocular syndrome were studied by means of carotid ultrasonography (US) and brain computerized tomography (CT). The subjects comprised 21 patients with AF, 37 with RAO, and 35 with RVO who were sequentially given these diagnoses by the department of ophthalmology. On the basis of US findings, carotid lesions were defined as the presence of plaque or stenotic changes. CT findings were assessed for the presence and distribution of low-density areas (LDAs). Mean age was similar in each group, ranging from 64.5 to 67.4 years. The RAO group had high rates of men, hypertension, and smokers. US showed that the prevalence of carotid lesions ipsilateral to the affected eye was high in the RAO group and that severe stenosis and ulcerated plaque were present in 28.6% of the AF group and 45.9% of the RAO group. On CT examination, cerebral infarctions appeared as LDAs in about 10% of the patients in each group, and the incidence and distribution of LDAs were similar. Of 13 patients with cerebral infarction, only 2 were presumably due to carotid lesions; the others had a variety of causes. The discrepancy between US and CT findings was attributed to the small number of patients with cerebral infarction, since most patients had visual defects as an initial symptom. Our results suggest that extracranial carotid lesions, considered to be a major risk factor for stroke, should be carefully assessed in patients with AF or RAO to prevent further stroke. (author)

  11. Absorbed dose to the patient by computerized whole body X-ray tomography

    International Nuclear Information System (INIS)

    Krauss, O.; Schuhmacher, H.

    1977-01-01

    The absorbed dose to the patient was measured for several medical investigations by computerized whole body scanning. An Alderson-phantom mounted with LiF-TLD was irradiated with a Delta-Scan (Ohio-Nuclear, 120 kV, 30 mA). The integral dose to the brain during a full examination (6 scans, filtration 3 mm Al) was measured to 5x10 -2 J. The maximum absorbed dose at the entrance was found to be 3.2 rd and at the exit 0.6 rd. The dose to the eyes is 0.7 rd and to the thyroid gland 0.03 rd. The integral dose to the trunk (5 scans in the region of liver and kidneys, filtration 6 mm Al) was measured to 5x10 -2 J. The maximum absorbed dose at the entrance was found to be 2.4 rd and at the exit 0.25 rd. The dose to the gonads is less than 2 and 4 mrd if the distance between the last scan and the gonads is more than 15 cm

  12. The F-SCAN system of foot pressure analysis.

    Science.gov (United States)

    Young, C R

    1993-07-01

    The age of computerized gait analysis is here. There are several systems available to meet the needs of the podiatric practitioner. This author believes that the F-SCAN technology system makes a significant contribution to the practice of podiatric medicine. The system is user friendly, accurate, reproducible, and affordable. Its graphic display capabilities are colorfully attractive and easily understood. The primary focus of the F-SCAN system is that of peak pressure distribution over time. Vertical plantar pressure dispersion across the plantar surface of the foot is recorded, processed, and graphically displayed in terms of sequential gait changes. The system further allows for the manipulation of the accumulated data to present it in a more comprehensive manner. Future updates on the F-SCAN software are already close at hand and are expected to enhance the diagnostic capabilities of the system further. The four primary areas of clinical application for F-SCAN have been identified and briefly discussed. The recognition of certain biomechanical abnormalities, monitoring preorthotic and postorthotic use, evaluation of the diabetic or neuropathic foot, and presurgical and postsurgical functional examinations constitute this group. The F-SCAN system largely helps to remove some of the unavoidable guess work from essential diagnostic and therapeutic procedures. As we increase our understanding of the pathomechanics of these clinical problems, so too will we improve our management of the associated complications. Years ago, at the time when computerized gait analysis was being introduced to the podiatric profession, a frequently asked question was: What does it tell me that I don't already know or can't see by watching the patient walk?(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Reconstructed image quality analysis of an industrial instant non-scanning tomography system with different types of collimators by the Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Velo, Alexandre F.; Carvalho, Diego V.; Alvarez, Alexandre G.; Hamada, Margarida M.; Mesquita, Carlos H., E-mail: afvelo@usp.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The greatest impact of the tomography technology application currently occurs in medicine. The great success of medical tomography is due to the human body presents reasonably standardized dimensions with well established chemical composition. Generally, these favorable conditions are not found in large industrial objects. In the industry there is much interest in using the information of the tomograph in order to know the interior of: (1) manufactured industrial objects or (2) machines and their means of production. In these cases, the purpose of the tomograph is to: (a) control the quality of the final product and (b) optimize production, contributing to the pilot phase of the projects and analyzing the quality of the means of production. In different industrial processes, e. g. in chemical reactors and distillation columns, the phenomena related to multiphase processes are usually fast, requiring high temporal resolution of the computed tomography (CT) data acquisition. In this context, Instant non-scanning tomograph and fifth generation tomograph meets these requirements. An instant non scanning tomography system is being developed at the IPEN/CNEN. In this work, in order to optimize the system, this tomograph comprised different collimators was simulated, with Monte Carlo method using the MCNP4C. The image quality was evaluated with MATLAB® 2013b, by analysis of the following parameters: contrast to noise (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to analyze which collimator fits better to the instant non scanning tomography. It was simulated three situations; (1) with no collimator; (2) ?25 mm x 50 mm cylindrical collimator with a septum of ø5.0 mm x 50 mm; (3) ø25 mm x 50 mm cylindrical collimator with a slit septum of 24 mm x 5.0 mm x 50 mm. (author)

  14. Reconstructed image quality analysis of an industrial instant non-scanning tomography system with different types of collimators by the Monte Carlo simulation

    International Nuclear Information System (INIS)

    Velo, Alexandre F.; Carvalho, Diego V.; Alvarez, Alexandre G.; Hamada, Margarida M.; Mesquita, Carlos H.

    2017-01-01

    The greatest impact of the tomography technology application currently occurs in medicine. The great success of medical tomography is due to the human body presents reasonably standardized dimensions with well established chemical composition. Generally, these favorable conditions are not found in large industrial objects. In the industry there is much interest in using the information of the tomograph in order to know the interior of: (1) manufactured industrial objects or (2) machines and their means of production. In these cases, the purpose of the tomograph is to: (a) control the quality of the final product and (b) optimize production, contributing to the pilot phase of the projects and analyzing the quality of the means of production. In different industrial processes, e. g. in chemical reactors and distillation columns, the phenomena related to multiphase processes are usually fast, requiring high temporal resolution of the computed tomography (CT) data acquisition. In this context, Instant non-scanning tomograph and fifth generation tomograph meets these requirements. An instant non scanning tomography system is being developed at the IPEN/CNEN. In this work, in order to optimize the system, this tomograph comprised different collimators was simulated, with Monte Carlo method using the MCNP4C. The image quality was evaluated with MATLAB® 2013b, by analysis of the following parameters: contrast to noise (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to analyze which collimator fits better to the instant non scanning tomography. It was simulated three situations; (1) with no collimator; (2) ?25 mm x 50 mm cylindrical collimator with a septum of ø5.0 mm x 50 mm; (3) ø25 mm x 50 mm cylindrical collimator with a slit septum of 24 mm x 5.0 mm x 50 mm. (author)

  15. Tomographic Small-Animal Imaging Using a High-Resolution Semiconductor Camera

    Science.gov (United States)

    Kastis, GA; Wu, MC; Balzer, SJ; Wilson, DW; Furenlid, LR; Stevenson, G; Barber, HB; Barrett, HH; Woolfenden, JM; Kelly, P; Appleby, M

    2015-01-01

    We have developed a high-resolution, compact semiconductor camera for nuclear medicine applications. The modular unit has been used to obtain tomographic images of phantoms and mice. The system consists of a 64 x 64 CdZnTe detector array and a parallel-hole tungsten collimator mounted inside a 17 cm x 5.3 cm x 3.7 cm tungsten-aluminum housing. The detector is a 2.5 cm x 2.5 cm x 0.15 cm slab of CdZnTe connected to a 64 x 64 multiplexer readout via indium-bump bonding. The collimator is 7 mm thick, with a 0.38 mm pitch that matches the detector pixel pitch. We obtained a series of projections by rotating the object in front of the camera. The axis of rotation was vertical and about 1.5 cm away from the collimator face. Mouse holders were made out of acrylic plastic tubing to facilitate rotation and the administration of gas anesthetic. Acquisition times were varied from 60 sec to 90 sec per image for a total of 60 projections at an equal spacing of 6 degrees between projections. We present tomographic images of a line phantom and mouse bone scan and assess the properties of the system. The reconstructed images demonstrate spatial resolution on the order of 1–2 mm. PMID:26568676

  16. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    A tomographic array with the following characteristics is described. An X-ray screen serving as detector is placed before a photomultiplier tube which itself is placed in front of a television camera connected to a set of image processors. The detector is concave towards the source and is replacable. Different images of the object are obtained simultaneously. Optical fibers and lenses are used for transmission within the system

  17. Fluorescent scanning x-ray tomography with synchrotron radiation

    Science.gov (United States)

    Takeda, Tohoru; Maeda, Toshikazu; Yuasa, Tetsuya; Akatsuka, Takao; Ito, Tatsuo; Kishi, Kenichi; Wu, Jin; Kazama, Masahiro; Hyodo, Kazuyuki; Itai, Yuji

    1995-02-01

    Fluorescent scanning (FS) x-ray tomography was developed to detect nonradioactive tracer materials (iodine and gadolinium) in a living object. FS x-ray tomography consists of a silicon (111) channel cut monochromator, an x-ray shutter, an x-ray slit system and a collimator for detection, a scanning table for the target organ, and an x-ray detector with pure germanium. The minimal detectable dose of iodine in this experiment was 100 ng in a volume of 2 mm3 and a linear relationship was shown between the photon counts of a fluorescent x ray and the concentration of iodine contrast material. A FS x-ray tomographic image was clearly obtained with a phantom.

  18. A positron emission tomograph designed for 3/4 mm resolution

    International Nuclear Information System (INIS)

    McInytre, J.A.; Allen, R.D.; Aguiar, J.; Paulson, J.T.

    1995-01-01

    Two factors of the design for a positron tomograph affect the magnitude of the tomograph spatial resolution: the gamma ray detector width and the analogue measurement of the scintillator location. In the tomograph design reported here the analogue measurement is eliminated and the detector transaxial width factor is reduced to 3/4 mm. The analogue measurement is eliminated by transmitting the scintillation light from each individual scintillator through optical fibers to four photo-multipliers (PMT's); the identities of the PMT's then provide a digital address for the scintillation location. Plastic scintillators are used to provide enough scintillation light for transmission through the optical fibers. Bonuses from the use of plastic scintillators are first, the reduction of the scintillator dead time to about 10 nsec, second, a large reduction of cross-talk between neighboring scintillators, third, the reduction of resolution loss from off-axis gamma rays and, fourth, the ability to sample the axial image at one-eighth the axial resolution distance of 2.5 mm. The designed tomograph incorporates 20 rings. Two of the 32 tomograph 20-ring modules have been constructed to measure the resolution and other characteristics of the tomographs

  19. Interpolation-free scanning and sampling scheme for tomographic reconstructions

    International Nuclear Information System (INIS)

    Donohue, K.D.; Saniie, J.

    1987-01-01

    In this paper a sampling scheme is developed for computer tomography (CT) systems that eliminates the need for interpolation. A set of projection angles along with their corresponding sampling rates are derived from the geometry of the Cartesian grid such that no interpolation is required to calculate the final image points for the display grid. A discussion is presented on the choice of an optimal set of projection angles that will maintain a resolution comparable to a sampling scheme of regular measurement geometry, while minimizing the computational load. The interpolation-free scanning and sampling (IFSS) scheme developed here is compared to a typical sampling scheme of regular measurement geometry through a computer simulation

  20. Introduction to curved rotary tomographic apparatus 'TOMOREX'

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Shinojima, Masayasu; Kohirasawa, Hideo; Tokui, Mitsuru

    1980-01-01

    In recent years, panorama X-ray photographic method is widely used for the X-ray diagnosis of teeth, jawbones and faces. One type based on the principle of tomography is curved surface rotary tomographic method utilizing fine-gap X-ray beam. With the synchronous rotation of an X-ray tube and a photographic film around a face, describing a U-shaped tomographic plane along a dental arch, an upper or lower jawbone is photographed. In the ''TOMOREX'' belonging to this type, is different tomographic planes are available, so that by selecting any position in advance, the part can be photographed. Furthermore, patients can be subjected to examination as laid on a stretcher. The mechanism and equipment, and the photographic method for eye sockets, cheekbones, upper jaw cavities and stereoscopic images are described. (J.P.N.)

  1. Assessment of Minimal HE (with emphasis on computerized psychometric tests)

    Science.gov (United States)

    Kappus, Matthew R; Bajaj, Jasmohan S

    2012-01-01

    Synopsis Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life and driving accidents. The detection of MHE requires specialized testing since it cannot by definition, be diagnosed on standard clinical examination. Psychometric (paper-pencil or computerized or a combination) and neuro-physiological techniques are often used to test for MHE. Paper-pencil psychometric batteries like the Psychometric Hepatic Encephalopathy Score (PHES) have been validated in several countries but do not have US normative values. Computerized tests such as the inhibitory control test (ICT), cognitive drug research system and Scan test have proven useful to diagnose MHE and predict outcomes. The specificity and sensitivity of these tests are similar to the recommended gold standards. Neuro-physiological tests such as the EEG and its interpretations, evoked potentials and Critical Flicker Frequency (CFF) also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike and the testing strategies depend on the normative data available, patient comfort and local expertise. PMID:22321464

  2. Paralisia cerebral hemiparética: fatores de risco etiológico e neuroimagem

    OpenAIRE

    Piovesana, Ana Maria Sedrez Gonzaga; Moura-Ribeiro, Maria Valeriana Leme de; Zanardi, Verônica de Araújo; Gonçalves, Vanda Maria Gimenes

    2001-01-01

    The purpose of this paper, which was conducted on 175 children with hemiparetic cerebral palsy (H-CP), was to verify the etiological risk period for this disease. Etiological risk factors (ERF) were detected through anamnesis: 23% in the prenatal period, 18% in the perinatal period and 59% of the patients the period was undefined (ERF in the prenatal and perinatal period was 41% and no ERF was 18% of the cases. The computerized tomographic scan (CT) and MRI were performed on all the patients,...

  3. On the pathogenesis of traumatic intracerebral hematoma with a sequential study of computerized tomography

    International Nuclear Information System (INIS)

    Ohmori, Hidetoshi; Miyazaki, Shinichiro; Munekata, Katsuharu; Fukushima, Hiromi; Shohji, Akira.

    1981-01-01

    A sequential study with computerized tomography (CT scan) of two cases of traumatic intracerebral hematoma is reported. Case 1 was a 69-year-old man who had a head injury. The initial CT scan, taken 1 hour after his injury, showed a left temporal salt-and-pepper appearance, which proved to be a cerebral contusion. The CT scan 4.5 hours after his injury showed a left temporal high density area instead. An operation was performed, and a massive intracerebral hematoma was observed. Case 2 was a 61-year-old man who was also admitted because of a head injury. The initial CT scan, taken 1 hour after his injury, revealed several bifrontal intracerebral hemorrhagic spots in the low-density areas, suggesting contusion. A secondary CT scan (23 hours) demonstrated that the traumatic intracerebral hematoma had developed into a posttraumatic cerebral contusion. The operation disclosed a hematoma surrounded by contusion. These cases prove that traumatic intracerebral hematoma is often caused by cerebral contusion. (author)

  4. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration of a tomographic array in which the object can rotate about its axis is described. The X-ray detector is a cylindrical screen perpendicular to the axis of rotation. The X-ray source has a line-shaped focus coinciding with the axis of rotation. The beam is fan-shaped with one side of this fan lying along the axis of rotation. The detector screen is placed inside an X-ray image multiplier tube

  5. Computerized adaptive testing in computer assisted learning?

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; Eggen, Theodorus Johannes Hendrikus Maria; De Wannemacker, Stefan; Clarebout, Geraldine; De Causmaecker, Patrick

    2011-01-01

    A major goal in computerized learning systems is to optimize learning, while in computerized adaptive tests (CAT) efficient measurement of the proficiency of students is the main focus. There seems to be a common interest to integrate computerized adaptive item selection in learning systems and

  6. Terahertz wave tomographic imaging with a Fresnel lens

    Institute of Scientific and Technical Information of China (English)

    S. Wang; X.-C. Zhang

    2003-01-01

    We demonstrate three-dimensional tomographic imaging using a Fresnel lens with broadband terahertz pulses. Objects at various locations along the beam propagation path are uniquely imaged on the same imaging plane using a Fresnel lens with different frequencies of the imaging beam. This procedure allows the reconstruction of an object's tomographic contrast image by assembling the frequency-dependent images.

  7. Computerized literature reference system: use of an optical scanner and optical character recognition software.

    Science.gov (United States)

    Lossef, S V; Schwartz, L H

    1990-09-01

    A computerized reference system for radiology journal articles was developed by using an IBM-compatible personal computer with a hand-held optical scanner and optical character recognition software. This allows direct entry of scanned text from printed material into word processing or data-base files. Additionally, line diagrams and photographs of radiographs can be incorporated into these files. A text search and retrieval software program enables rapid searching for keywords in scanned documents. The hand scanner and software programs are commercially available, relatively inexpensive, and easily used. This permits construction of a personalized radiology literature file of readily accessible text and images requiring minimal typing or keystroke entry.

  8. Wide-band antenna design for use in minimal-scan, microwave tomographic imaging

    Science.gov (United States)

    Klaser, Jacob

    Microwave tomography is widely used in biomedical imaging and nondestructive evaluation of dielectric materials. A novel microwave tomography system that uses an electrically-conformable mirror to steer the incident energy for producing multi-view projection data is being developed in the Non-Destructive Evaluation Laboratory (NDEL). Such a system will have a significant advantage over existing tomography systems in terms of simplicity of design and operation, particularly when there is limited-access of the structure that is being imaged. The major components of a mirror-based tomography system are the source mirror assembly, and a receiver array for capturing the multi-view projection data. This thesis addresses the design and development of the receiver array. This imaging array features balanced, anti-podal Vivaldi antennas, which offer large bandwidth, high gain and a compact size. From the simulations, as well as the experimental results for the antenna, the return loss (S 11) is below -10dB for the range from 2.2GHz to 8.2GHz, and the gain is measured to be near 6dB. The data gathered from the receiver array is then run through MATLAB code for tomographic reconstruction using the Filtered Back-Propagation algorithm from limited-view projections. Initial results of reconstruction from the measured data shows the feasibility of the approach, but a significant challenge remains in interpolating the data for a limited number of receiving antenna elements and removing noise from the reconstructed image.

  9. Industrial dynamic tomographic reconstruction

    International Nuclear Information System (INIS)

    Oliveira, Eric Ferreira de

    2016-01-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  10. Classification of lymph nodes in computerized tomography scans using extracting tools

    International Nuclear Information System (INIS)

    Alves, Allan F.F.; Pina, Diana R. de; Altemani, Joao M.C.

    2016-01-01

    Lymph node changes in the neck region may be originated by both inflammatory and tumor causes. Diagnostic imaging method such as computed tomography are used to distinguish between these two main causes of lymph nodes alterations. In this work we used feature extracting tools I CT scans such as the average value of pixels, wavelet entropy, skewness and kurtosis to assist the radiologist in diagnosing lymph nodes alterations. The wavelet entropy proved to be the best image characteristic parameter to differentiate between the two groups of patients evaluated in this study. The study of cervical lymph nodes changes by features extraction methods may prove to be an excellent tool to assist in differentiating between infectious / inflammatory and tumor causes in CT scans. (author)

  11. Computerized axial tomography of the chest for visualization of ''absent'' pulmonary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sondheimer, H.M. (Upstate Medical Center, Syracuse, NY); Oliphant, M.; Schneider, B.; Kavey, R.E.W.; Blackman, M.S.; Parker, F.B. Jr.

    1982-05-01

    To expand the search for central pulmonary arteries in six patients with absence of cardiac-pulmonary continuity, computerized axial tomography (CAT) of the chest was performed. The CAT scans were compared with previous arteriograms and pulmonary vein wedge angiograms. Three patients with type IV truncus arteriosus were studied, and none had a central, right or left pulmonary artery on CAT scan. However, two patients with tetralogy of Fallot with pulmonary atresia and a patent ductus arteriosus to the right lung demonstrated the presence of a left pulmonary artery. In addition, one child with truncus arteriosus with ''absent'' left pulmonary artery demonstrated a left pulmonary artery on the CAT scan. The CAT scan may therefore enhance our ability to search for disconnected pulmonary arteries in children with complex cyanotic congenital heart disease.

  12. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    International Nuclear Information System (INIS)

    Marchiori, Edson; Irion, Klaus Loureiro; Zanetti, Glaucia; Missrie, Israel; Sato, Juliana

    2008-01-01

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  13. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Meirelles, Gustavo Souza Portes [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil); Irion, Klaus Loureiro [The Royal Liverpool University Hospital, Liverpool (United Kingdom); Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil); Missrie, Israel [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Diagnostico por Imagem; Sato, Juliana [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Otorrinolaringologia e Cirurgia de Cabeca e Pescoco

    2008-12-15

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  14. Human Reliability Analysis For Computerized Procedures

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Gertman, David I.; Le Blanc, Katya

    2011-01-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  15. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    Science.gov (United States)

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  16. Analysis of the percentage voids of test and field specimens using computerized tomography

    International Nuclear Information System (INIS)

    Braz, D.; Lopes, R.T.; Motta, L.M.G. da

    1999-01-01

    Computerized tomography has been an excellent tool of analysis of asphaltics mixtures, because it allows comparison of the quality and integrity of test and field specimens. It was required to detect and follow the evolution of cracks, when these mixtures were submitted to fatigue tests, and also helping to interpret the distribution of tensions and deformations which occur in the several types of solicitations imposed to the mixtures. Comparing the medium values of percentage voids obtained from tomographic images with the project's values, it can be observed that the values of test and field specimens for the wearing course are closer to the ones of the project than the ones of the binder. It can be verified that the wearing course specimens always present a distribution of the aggregate, and voids quite homogeneously in the whole profile of the sample, while the binder specimens show an accentuated differentiation of the same factors in the several heights of the sample. Therefore, when choosing a slice for tomography, these considerations should be taken into account

  17. Tomographic findings of gastric gastrointestinal stromal tumor: a 14-case study

    International Nuclear Information System (INIS)

    Pelandre, Gustavo Lemos; Djahjah, Maria Celia; Nobre, Luiz Felipe; Gasparetto, Emerson Leandro; Marchiori, Edson; Pereira, Bruno Vilhena; Valadao, Marcus; Linhares, Eduardo

    2008-01-01

    Objective: The purpose of this study was to describe the tomographic findings of gastric gastrointestinal stromal tumor. Materials and methods: Fourteen patients with histopathologically and immunohistochemically confirmed gastric gastrointestinal stromal tumors, who had already been submitted to computed tomography scans before the treatment, were evaluated in the period between January 1999 and December 2006. The following tomographic variables were analyzed: lesion topography, size/dimensions, homogeneity, contour, margins, morphology, pattern and intravenous contrast-enhancement intensity, growth pattern, invasion of adjacent organs, presence of ulceration, fistula, calcifications, mesenteric fat infiltration, lymphadenomegaly and presence of distant metastasis. Results: Tumors were found in the body (57.1%) or in the gastric fundus (42.9%), with sizes ranging between 6.0 cm and 23.0 cm (mean, 11.5 cm). Predominantly extra luminal growth was observed in 57.1% of cases and intra/extra luminal in 35.7%. Subtle contrast-enhancement was observed in 50%, moderate in 50%, and heterogeneous in 64.3% of cases. Additionally, central hypodensity was observed in 64.3%, invasion of adjacent organs in 42.9%, and hepatic metastasis in 7.2% of cases. Conclusion: In the present study, the majority of tumors were found in the gastric body, with an average size of 11.5 cm, presenting with central hypodensity, heterogeneous contrast-enhancement and predominantly extraluminal growth. (author)

  18. Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

    International Nuclear Information System (INIS)

    Shibata, Koichi; Notohara, Daisuke; Sakai, Takihito

    2014-01-01

    Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the

  19. Parallel-scanning tomosynthesis using a slot scanning technique: fixed-focus reconstruction and the resulting image quality.

    Science.gov (United States)

    Shibata, Koichi; Notohara, Daisuke; Sakai, Takihito

    2014-11-01

    Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)-(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of -100, -50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A

  20. Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Koichi, E-mail: shibatak@suzuka-u.ac.jp [Department of Radiological Technology, Faculty of Health Science, Suzuka University of Medical Science 1001-1, Kishioka-cho, Suzuka 510-0293 (Japan); Notohara, Daisuke; Sakai, Takihito [R and D Department, Medical Systems Division, Shimadzu Corporation 1, Nishinokyo-Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511 (Japan)

    2014-11-01

    Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the

  1. Tomographic Approach in Three-Orthogonal-Basis Quantum Key Distribution

    International Nuclear Information System (INIS)

    Liang Wen-Ye; Yin Zhen-Qiang; Chen Hua; Li Hong-Wei; Chen Wei; Han Zheng-Fu; Wen Hao

    2015-01-01

    At present, there is an increasing awareness of some three-orthogonal-basis quantum key distribution protocols, such as, the reference-frame-independent (RFI) protocol and the six-state protocol. For secure key rate estimations of these protocols, there are two methods: one is the conventional approach, and another is the tomographic approach. However, a comparison between these two methods has not been given yet. In this work, with the general model of rotation channel, we estimate the key rate using conventional and tomographic methods respectively. Results show that conventional estimation approach in RFI protocol is equivalent to tomographic approach only in the case of that one of three orthogonal bases is always aligned. In other cases, tomographic approach performs much better than the respective conventional approaches of the RFI protocol and the six-state protocol. Furthermore, based on the experimental data, we illustrate the deep connections between tomography and conventional RFI approach representations. (paper)

  2. A critical comparison of clinical decision instruments for computed tomographic scanning in mild closed traumatic brain injury in adolescents and adults.

    Science.gov (United States)

    Stein, Sherman C; Fabbri, Andrea; Servadei, Franco; Glick, Henry A

    2009-02-01

    A number of clinical decision aids have been introduced to limit unnecessary computed tomographic scans in patients with mild traumatic brain injury. These aids differ in the risk factors they use to recommend a scan. We compare the instruments according to their sensitivity and specificity and recommend ones based on incremental benefit of correctly classifying patients as having surgical, nonsurgical, or no intracranial lesions. We performed a secondary analysis of prospectively collected database from 7,955 patients aged 10 years or older with mild traumatic brain injury to compare sensitivity and specificity of 6 common clinical decision strategies: the Canadian CT Head Rule, the Neurotraumatology Committee of the World Federation of Neurosurgical Societies, the New Orleans, the National Emergency X-Radiography Utilization Study II (NEXUS-II), the National Institute of Clinical Excellence guideline, and the Scandinavian Neurotrauma Committee guideline. Excluded from the database were patients for whom the history of trauma was unclear, the initial Glasgow Coma Scale score was less than 14, the injury was penetrating, vital signs were unstable, or who refused diagnostic tests. Patients revisiting the emergency department within 7 days were counted only once. The percentage of scans that would have been required by applying each of the 6 aids were Canadian CT head rule (high risk only) 53%, Canadian (medium & high risk) 56%, the Neurotraumatology Committee of the World Federation of Neurosurgical Societies 56%, New Orleans 69%, NEXUS-II 56%, National Institute of Clinical Excellence 71%, and the Scandinavian 50%. The 6 decision aids' sensitivities for surgical hematomas could not be distinguished statistically (P>.05). Sensitivity was 100% (95% confidence interval [CI] 96% to 100%) for NEXUS-II, 98.1% (95% CI 93% to 100%) for National Institute of Clinical Excellence, and 99.1% (95% CI 94% to 100%) for the other 4 clinical decision instruments. Sensitivity for

  3. Computerized tomographic study on the brain of patients with alcohol dependence

    International Nuclear Information System (INIS)

    Kato, Akira; Tsuji, Motohiro; Nakamura, Michihiko; Nakajima, Teruo.

    1991-01-01

    One hundred ten patients with alcohol dependence and 56 psychiatric patients with either senile dementia, amphetamine psychosis, epilepsy or chronic schizophrenia were investigated with a CT scan of the brain. The maximum width of the 3rd ventricle was measured, and the presence/absence of enlargement of the lateral ventricle and of atrophy of the frontal lobe was determined independently by 3 physicians. The width of the 3rd ventricle in alcoholic and the other patients examined was gradually enlarged with aging, and the width in these patients was significantly larger than that in the age-matched control patients who were selected from the patients with amphetamine psychosis, epilepsy or schizophrenia. The enlargement of the lateral ventricles observed in the alcoholic patients always accompanied the enlargement of the 3rd ventricle, but not vice versa. The alcoholic patients with frontal lobe atrophy showed a higher incidence of withdrawal delirium than the patients without atrophy. These findings suggest that the chronic intake of alcohol might affect primarily the area around the 3rd ventricle, resulting in enlargement of this ventricle and consequential enlargement of the lateral ventricles and also that the alcoholic patients with frontal lobe atrophy could have a high risk for a manifestation of alcoholic withdrawal delirium. (author)

  4. Computerized tomographic evaluation of chronic ischemic lesions in cerebral white matter

    International Nuclear Information System (INIS)

    Yamanouchi, Hiroshi; Tohgi, Hideo; Iio, Masahiro; Tomonaga, Masanori.

    1981-01-01

    The purpose of this study is to clarify the correlation between the low density areas and periventricular lucency (PVL) on CT and the histopathologic changes of chronic ischemic lesions in cerebral white matter. Thirty seven brains from chronic cases with stroke and 17 brains from patients who showed PVLs on CT were examined histologically. CT scans were performed using GE CT/T. Chronic ischemic lesions with severe demyelination or diffuse cavitation were detected as low density areas on CT. But if associated with severe gliosis, those lesions could not be detected on CT. Areas with myelin pallor could not be detected on CT. In some cases diffuse ischemic lesions as demyelination and cavitation were found in the areas corresponding to PVLs on CT. However, they were not always expressed on CT. Other cases with PVL had no histological changes in the frontal white matter. In conclusion, chronic ischemic lesions in the cerebral white matter could not always be detected as low density areas on CT. This may be partly because decreased density due to demyelination and cavitation was counterbalanced by severe gliosis which tends to increase the density. In some cases PVLs were related to diffuse ischemic lesions in the frontal white matter, but this was not always the case. (author)

  5. Tuberculosis of the Parotid Gland: Computed Tomographic Findings

    International Nuclear Information System (INIS)

    Wei, Y.; Xiao, J.; Pui, M.H.; Gong, Q.

    2008-01-01

    Background: Tuberculosis (TB) of the parotid gland is rare, even in endemic regions. Approximately 100 cases have been reported in the English literature. The computed tomographic (CT) features, however, have seldom been studied. Purpose: To determine the diagnostic CT features of tuberculosis of the parotid gland. Material and Methods: CT studies of four histologically proven cases of tuberculosis of the parotid gland were retrospectively reviewed. Results: A total of 15 enlarged lymph nodes were found in the superficial lobes of the parotid glands. The nodes were arranged linearly within the gland. Enhancement patterns included homogeneous enhancement (9/15, 60%), homogeneous enhancement with eccentric microcysts (3/15, 20%), and thick-walled rim enhancement with central lucency (3/15, 20%). Thickened adjacent fascial plane and platysma were seen in two patients. Ipsilateral cervical lymphadenopathy was seen in all patients. Conclusion: In patients presenting with unilateral parotid nodules, TB should be considered when linearly arranged enhancing nodules are demonstrated in the superficial lobes of the glands on CT scan

  6. Osmotic blood-brain barrier modification: clinical documentation by enhanced CT scanning and/or radionuclide brain scanning

    International Nuclear Information System (INIS)

    Neuwelt, E.A.; Specht, H.D.; Howieson, J.; Haines, J.E.; Bennett, M.J.; Hill, S.A.; Frenkel, E.P.

    1983-01-01

    Results of initial clinical trials of brain tumor chemotherapy after osmotic blood-brain barrier disruption are promising. In general, the procedure is well tolerated. The major complication has been seizures. In this report, data are presented which indicate that the etiology of these seizures is related to the use of contrast agent (meglumine iothalamate) to monitor barrier modification. A series of 19 patients underwent a total of 85 barrier modification procedures. Documentation of barrier disruption was monitored by contrast-enhanced computed tomographic (CT) scanning, radionuclide brain scanning, or a combination of both techniques. In 56 procedures (19 patients) monitored by enhanced CT, seizures occurred a total of 10 times in eight patients. Twenty-three barrier modification procedures (in nine of these 19 patients) documented by nuclear brain scans alone, however, resulted in only one focal motor seizure in each of two patients. In eight of the 19 patients who had seizures after barrier disruption and enhanced CT scan, four subsequently had repeat procedures monitored by radionuclide scan alone. In only one of these patients was further seizure activity noted; a single focal motor seizure was observed. Clearly, the radionuclide brain scan does not have the sensitivity and spatial resolution of enhanced CT, but at present it appears safer to monitor barrier modification by this method and to follow tumor growth between barrier modifications by enhanced CT. Four illustrative cases showing methods, problems, and promising results are presented

  7. Computed tomographic findings of intracranial pyogenic abscess

    International Nuclear Information System (INIS)

    Kim, S. J.; Suh, J. H.; Park, C. Y.; Lee, K. C.; Chung, S. S.

    1982-01-01

    The early diagnosis and effective treatment of brain abscess pose a difficult clinical problem. With the advent of computed tomography, however, it appears that mortality due to intracranial abscess has significantly diminished. 54 cases of intracranial pyogenic abscess are presented. Etiologic factors and computed tomographic findings are analyzed and following result are obtained. 1. The common etiologic factors are otitis media, post operation, and head trauma, in order of frequency. 2. The most common initial computed tomographic findings of brain abscess is ring contrast enhancement with surrounding brain edema. 3. The most characteristic computed tomographic finding of ring contrast enhancement is smooth thin walled ring contrast enhancement. 4. Most of thick irregular ring contrast enhancement are abscess associated with cyanotic heart disease or poor operation. 5. The most common findings of epidural and subdural empyema is crescentic radiolucent area with thin wall contrast enhancement without surrounding brain edema in convexity of brain

  8. Acute renal failure following contrast injection for head computerized tomography in two patients with diabetic nephropathy

    International Nuclear Information System (INIS)

    Matsunaga, Hiroshi; Sando, Hiroyuki; Nunokawa, Tomoo; Murakami, Tooru; Miyakawa, Yuzo

    1981-01-01

    Two cases of diabetes mellitus with renal and retinal involvement developed acute renal failure after undergoing head computerized tomography. The first case was a 62-year-old male who had been diagnosed as having diabetes 25 years before. He had diabetic retinopathy of Scott IIIb. Before head computerized tomography, the serum BUN was 37 mg/dl, and creatinine was 4.1 mg/dl. Oliguria began immediately after the scanning and confinued for 48 hr. The serum levels of BUN and creatinine rose to 106 and 7.7 mg/dl, respectively. Case 2 was a 49-year-old male who had been diagnosed as having diabetes 15 years before. He showed Scott IIb and IV retinopathy. The BUN and creatinine levels in the serum were 32 and 2.3 mg/dl, respectively. After receiving head computerized tomography, he developed oliguria and remained oliguric for 48 hr. During that period, the serum levels of BUN and creatinin were elevated to 112 and 7.5 mg/dl, respectively. Fortunately, both of these patients recovered from the oliguria without resorting to hemodialysis. The iodine contrast medium routinely used for contrast enhancement in the head computerized tomography was implicated in the acute renal failure of these patients. Only elevn cases have so far been reported in the literature who developed acute renal failure following computerized tomography. In view of the three or four times greater dosis of iodine contrast medium employed in computerized tomography compared to intravenous pyelography, the acute incidence of such complications might be much higher. Among the thirteen cases including the two reported here, as many as eight were diabetic. It is well recongnized that the incidence of acute renal failure after intravenous pyelography is particularly high in cases of diabetic nephropathy. (author)

  9. The Use of CT Scan in Hemodynamically Stable Children with Blunt Abdominal Trauma : Look before You Leap

    NARCIS (Netherlands)

    Nellensteijn, David R.; Greuter, Marcel J.; el Moumni, Moustafa; Hulscher, Jan B.

    We set out to determine the diagnostic value of computed tomographic (CT) scans in relation to the radiation dose, tumor incidence, and tumor mortality by radiation for hemodynamically stable pediatric patients with blunt abdominal injury. We focused on the changes in management because of new

  10. Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs

    International Nuclear Information System (INIS)

    Nelson, Geoff; Fahrig, Rebecca; Yoon, Sungwon; Krishna, Ganesh; Wilfley, Brian

    2013-01-01

    Purpose: An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geometry of the system requires trade-offs between patient dose, imaging field of view (FOV), and tomographic angle.Methods: Tomosynthetic angle as a function of tumor-to-detector distance was calculated. Monte Carlo Software (PCXMC) was used to calculate organ doses and effective dose for source-to-detector distances (SDDs) from 90 to 150 cm, patient locations with the tumor at 20 cm from the source to 20 cm from the detector, and FOVs centered on left lung and right lung as well as medial and distal peripheries of the lungs. These calculations were done for two systems, a SBDX system and a GE OEC-9800 C-arm fluoroscopic unit. To evaluate the dose effect of the system geometry, results from PCXMC were calculated using a scan of 300 mAs for both SBDX and fluoroscopy. The Rose Criterion was used to find the fluence required for a tumor SNR of 5, factoring in scatter, air-gap, system geometry, and patient position for all models generated with PCXMC. Using the calculated fluence for constant tumor SNR, the results from PCXMC were used to compare the patient dose for a given SNR between SBDX and fluoroscopy.Results: Tomographic angle changes with SDD only in the region near the detector. Due to their geometry, the source array and detector have a peak tomographic angle for any given SDD at a source to tumor distance that is 69.7% of the SDD assuming constant source and detector size. Changing the patient location in order to increase tomographic angle has a significant effect on organ dose distribution due to geometrical considerations. With SBDX and fluoroscopy geometries, the dose to organs typically changes in an opposing manner with changing patient

  11. Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Geoff; Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Yoon, Sungwon [Varian Medical Systems, Palo Alto, California 94304 (United States); Krishna, Ganesh [Palo Alto Medical Foundation, Mountain View, California 94040 (United States); Wilfley, Brian [Triple Ring Technologies, Inc., Newark, California 94560 (United States)

    2013-11-15

    Purpose: An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geometry of the system requires trade-offs between patient dose, imaging field of view (FOV), and tomographic angle.Methods: Tomosynthetic angle as a function of tumor-to-detector distance was calculated. Monte Carlo Software (PCXMC) was used to calculate organ doses and effective dose for source-to-detector distances (SDDs) from 90 to 150 cm, patient locations with the tumor at 20 cm from the source to 20 cm from the detector, and FOVs centered on left lung and right lung as well as medial and distal peripheries of the lungs. These calculations were done for two systems, a SBDX system and a GE OEC-9800 C-arm fluoroscopic unit. To evaluate the dose effect of the system geometry, results from PCXMC were calculated using a scan of 300 mAs for both SBDX and fluoroscopy. The Rose Criterion was used to find the fluence required for a tumor SNR of 5, factoring in scatter, air-gap, system geometry, and patient position for all models generated with PCXMC. Using the calculated fluence for constant tumor SNR, the results from PCXMC were used to compare the patient dose for a given SNR between SBDX and fluoroscopy.Results: Tomographic angle changes with SDD only in the region near the detector. Due to their geometry, the source array and detector have a peak tomographic angle for any given SDD at a source to tumor distance that is 69.7% of the SDD assuming constant source and detector size. Changing the patient location in order to increase tomographic angle has a significant effect on organ dose distribution due to geometrical considerations. With SBDX and fluoroscopy geometries, the dose to organs typically changes in an opposing manner with changing patient

  12. Design of aerosol face masks for children using computerized 3D face analysis.

    Science.gov (United States)

    Amirav, Israel; Luder, Anthony S; Halamish, Asaf; Raviv, Dan; Kimmel, Ron; Waisman, Dan; Newhouse, Michael T

    2014-08-01

    Aerosol masks were originally developed for adults and downsized for children. Overall fit to minimize dead space and a tight seal are problematic, because children's faces undergo rapid and marked topographic and internal anthropometric changes in their first few months/years of life. Facial three-dimensional (3D) anthropometric data were used to design an optimized pediatric mask. Children's faces (n=271, aged 1 month to 4 years) were scanned with 3D technology. Data for the distance from the bridge of the nose to the tip of the chin (H) and the width of the mouth opening (W) were used to categorize the scans into "small," "medium," and "large" "clusters." "Average" masks were developed from each cluster to provide an optimal seal with minimal dead space. The resulting computerized contour, W and H, were used to develop the SootherMask® that enables children, "suckling" on their own pacifier, to keep the mask on their face, mainly by means of subatmospheric pressure. The relatively wide and flexible rim of the mask accommodates variations in facial size within and between clusters. Unique pediatric face masks were developed based on anthropometric data obtained through computerized 3D face analysis. These masks follow facial contours and gently seal to the child's face, and thus may minimize aerosol leakage and dead space.

  13. Formal Verification of Computerized Procedure with Colored Petri Nets

    International Nuclear Information System (INIS)

    Kim, Yun Goo; Shin, Yeong Cheol

    2008-01-01

    Computerized Procedure System (CPS) supports nuclear power plant operators in performing operating procedures which are instructions to guide in monitoring, decision making and controlling nuclear power plants. Computerized Procedure (CP) should be loaded to CPS. Due to its execution characteristic, computerized procedure acts like a software in CPS. For example, procedure flows are determined by operator evaluation and computerized procedure logic which are pre-defined. So the verification of Computerized Procedure logic and execution flow is needed before computerized procedures are installed in the system. Formal verification methods are proposed and the modeling of operating procedures with Coloured Petri Nets(CP-nets) is presented

  14. Introduction of the Canadian CT Head Rule Reduces CT Scan Use ...

    African Journals Online (AJOL)

    amnesia or witnessed disorientation in a patient with a GCS score of 13–15 who has suffered a traumatic event, the evaluation of minor head injury using. Computerized Axial Tomography Scan of the Head. (CT-head) has remained controversial.(1,3). CT–head is expensive, time consuming, strenuous to human resource ...

  15. The Effects of Computerized Auditory Feedback on Electronic Article Surveillance Tag Placement in an Auto-Parts Distribution Center

    Science.gov (United States)

    Goomas, David T.

    2008-01-01

    In this report from the field, computerized auditory feedback was used to inform order selectors and order selector auditors in a distribution center to add an electronic article surveillance (EAS) adhesive tag. This was done by programming handheld computers to emit a loud beep for high-priced items upon scanning the item's bar-coded Universal…

  16. Technologies in computerized lexicography | Kruyt | Lexikos

    African Journals Online (AJOL)

    Although the topic of this paper is technology, focus is on functional rather than technical aspects of computerized lexicography. Keywords: computerized lexicography, electronic dictionary, electronic text corpus, lexicographer's workbench, integrated language database, automatic linguistic analysis, information retrieval, ...

  17. [Computerized medical record: deontology and legislation].

    Science.gov (United States)

    Allaert, F A; Dusserre, L

    1996-02-01

    Computerization of medical records is making headway for patients' follow-up, scientific research, and health expenses control, but it must not alter the guarantees provided to the patients by the medical code of ethics and the law of January 6, 1978. This law, modified on July 1, 1994, requires to register all computerized records of personal data and establishes rights to protect privacy against computer misdemeanor. All medical practitioners using computerized medical records must be aware that the infringement of this law may provoke suing in professional, civil or criminal court.

  18. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  19. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka

    1980-01-01

    The authors constructed a Multiple Pinhole Coded Aperture (MPCA) and developed related decoding software. When simple coordinate transformation was performed, omission of points and shifting of counts occurred. By selecting various tomographic planes and collecting count for each tomographic depth from the shadowgram, a solution to these problems was found. The counts from the central portion of the tomographic image from the MPCA were incorrectly high, this was rectified by a correction function to improve the uniformity correction program of the γ-camera. Depth resolution of the tomographic image improved in proportion to the area encompassed by the pinhole configuration. An MPCA with a uniform arrangement of pinholes (e, g, pinholes in an arrangement parallel to the X-axis or the Y-axis) yielded decoded tomographic images of inferior quality. Optimum results were obtained with a ring-shaped arrangement yielding clinically applicable tomographic images even for large objects. (author)

  20. Estimation of spatial uncertainties of tomographic velocity models

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, M.; Du, Z.; Querendez, E. [SINTEF Petroleum Research, Trondheim (Norway)

    2012-12-15

    This research project aims to evaluate the possibility of assessing the spatial uncertainties in tomographic velocity model building in a quantitative way. The project is intended to serve as a test of whether accurate and specific uncertainty estimates (e.g., in meters) can be obtained. The project is based on Monte Carlo-type perturbations of the velocity model as obtained from the tomographic inversion guided by diagonal and off-diagonal elements of the resolution and the covariance matrices. The implementation and testing of this method was based on the SINTEF in-house stereotomography code, using small synthetic 2D data sets. To test the method the calculation and output of the covariance and resolution matrices was implemented, and software to perform the error estimation was created. The work included the creation of 2D synthetic data sets, the implementation and testing of the software to conduct the tests (output of the covariance and resolution matrices which are not implicitly provided by stereotomography), application to synthetic data sets, analysis of the test results, and creating the final report. The results show that this method can be used to estimate the spatial errors in tomographic images quantitatively. The results agree with' the known errors for our synthetic models. However, the method can only be applied to structures in the model, where the change of seismic velocity is larger than the predicted error of the velocity parameter amplitudes. In addition, the analysis is dependent on the tomographic method, e.g., regularization and parameterization. The conducted tests were very successful and we believe that this method could be developed further to be applied to third party tomographic images.

  1. Generalized Row-Action Methods for Tomographic Imaging

    DEFF Research Database (Denmark)

    Andersen, Martin Skovgaard; Hansen, Per Christian

    2014-01-01

    Row-action methods play an important role in tomographic image reconstruction. Many such methods can be viewed as incremental gradient methods for minimizing a sum of a large number of convex functions, and despite their relatively poor global rate of convergence, these methods often exhibit fast...... initial convergence which is desirable in applications where a low-accuracy solution is acceptable. In this paper, we propose relaxed variants of a class of incremental proximal gradient methods, and these variants generalize many existing row-action methods for tomographic imaging. Moreover, they allow...

  2. Measuring irradiated lung and heart area in breast tangential fields using a simulator-based computerized tomography device

    International Nuclear Information System (INIS)

    Mallik, Raj; Fowler, Allan; Hunt, Peter

    1995-01-01

    Purpose: To illustrate the use of a simulator based computerized tomography system (SIMCT) in the simulation and planning of tangential breast fields. Methods and Materials: Forty-five consecutive patients underwent treatment planning using a radiotherapy simulator with computerized tomography attachment. One to three scans were obtained for each patient, calculations were made on the central axis scan. Due to the wide aperture of this system all patients were able to be scanned in the desired treatment position with arm abducted 90 deg. . Using available software tools the area of lung and/or heart included within the tangential fields was calculated. The greatest perpendicular distance (GPD) from the chest wall to posterior field edge was also measured. Results: The mean GPD for the group was 25.40 mm with 71% of patients having GPDs of ≤ 30 mm. The mean area of irradiated lung was 1780 sq mm which represented 18.0% of the total ipsilateral lung area seen in the central axis. Seven of the patients with left sided tumors had an average 1314 sq mm heart irradiated in the central axis. This represented 11.9% of total heart area in these patients. Conclusion: Measurements of irradiated lung and heart area can be easily and accurately made using a SIMCT device. Such measurements may help identify those patients potentially at risk for lung or heart toxicity as a consequence of their treatment. A major advantage of this device is the ability to scan patients in the actual treatment position

  3. Measuring irradiated lung and heart area in breast tangential fields using a simulator-based computerized tomography device

    Energy Technology Data Exchange (ETDEWEB)

    Mallik, Raj; Fowler, Allan; Hunt, Peter

    1995-01-15

    Purpose: To illustrate the use of a simulator based computerized tomography system (SIMCT) in the simulation and planning of tangential breast fields. Methods and Materials: Forty-five consecutive patients underwent treatment planning using a radiotherapy simulator with computerized tomography attachment. One to three scans were obtained for each patient, calculations were made on the central axis scan. Due to the wide aperture of this system all patients were able to be scanned in the desired treatment position with arm abducted 90 deg. . Using available software tools the area of lung and/or heart included within the tangential fields was calculated. The greatest perpendicular distance (GPD) from the chest wall to posterior field edge was also measured. Results: The mean GPD for the group was 25.40 mm with 71% of patients having GPDs of {<=} 30 mm. The mean area of irradiated lung was 1780 sq mm which represented 18.0% of the total ipsilateral lung area seen in the central axis. Seven of the patients with left sided tumors had an average 1314 sq mm heart irradiated in the central axis. This represented 11.9% of total heart area in these patients. Conclusion: Measurements of irradiated lung and heart area can be easily and accurately made using a SIMCT device. Such measurements may help identify those patients potentially at risk for lung or heart toxicity as a consequence of their treatment. A major advantage of this device is the ability to scan patients in the actual treatment position.

  4. Computerized axial tomography in the detection of brain damage

    International Nuclear Information System (INIS)

    Cala, L.A.; Mastaglia, F.L.

    1980-01-01

    The cranial computerized axial tomography (CAT) findings in groups of patients with epilepsy, migraine, hypertension, and other general medical disorders have been reviewed to assess the frequency and patterns of focal and diffuse brain damage. In addition to demonstrating focal lesions in a proportion of patients with seizures and in patients presenting with a stroke, the CAT scan showed a premature degree of cerebral atrophy in an appreciable proportion of patients with long-standing epilepsy, hypertension and diabetes, and in some patients with migraine, valvular and ischaemic heart disease, chronic obstructive airways disease, and chronic renal failure. The value of CAT as a means of screening for brain damage in groups of individuals at risk is discussed

  5. Tomographs based on non-conventional radiation sources and methods

    International Nuclear Information System (INIS)

    Barbuzza, R.; Fresno, M. del; Venere, Marcelo J.; Clausse, Alejandro; Moreno, C.

    2000-01-01

    Computer techniques for tomographic reconstruction of objects X-rayed with a compact plasma focus (PF) are presented. The implemented reconstruction algorithms are based on stochastic searching of solutions of Radon equation, using Genetic Algorithms and Monte Carlo methods. Numerical experiments using actual projections were performed concluding the feasibility of the application of both methods in tomographic reconstruction problem. (author)

  6. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  7. Translate rotate scanning method for X-ray imaging

    International Nuclear Information System (INIS)

    Eberhard, J.W.; Kwog Cheong Tam.

    1990-01-01

    Rapid x-ray inspection of objects larger than an x-ray detector array is based on a translate rotate scanning motion of the object related to the fan beam source and detector. The scan for computerized tomography imaging is accomplished by rotating the object through 360 degrees at two or more positions relative to the source and detector array, in moving to another position the object is rotated and the object or source and detector are translated. A partial set of x-ray data is acquired at every position which are combined to obtain a full data set for complete image reconstruction. X-ray data for digital radiography imaging is acquired by scanning the object vertically at a first position at one view angle, rotating and translating the object relative to the source and detector to a second position, scanning vertically, and so on to cover the object field of view, and combining the partial data sets. (author)

  8. Clinical and computerized evaluation in study of temporo-mandibular joint intracapsular disease.

    Science.gov (United States)

    Ciavarella, D; Mastrovincenzo, M; Sabatucci, A; Parziale, V; Granatelli, F; Violante, F; Bossù, M; Lo Muzio, L; Chimenti, C

    2010-03-01

    In this work authors show a diagnostic criteria in study of TMID: neuro occlusal clinical evaluation (NOE), T-Scan 2 system and surface electromyography (sEMG). Nine patients 25-30 years old with TMID problem and 9 healthy group control have been selected and examined. On each patients it has been performed NOE, T-Scan and sEMG test. NOE has been calculated on each patient photos lateral mandibular excursion angle called: masticatory functional angle (AFM). T-Scan System is a computerized occlusal analyzer that provide in-depth understanding of the overall balance of the occlusion. At the same time of T-Scan record sEMG tests, in resting position and in maximum clench, have been performed. In healthy control there were no AFM difference. In no healthy group there were difference between the two AFM greater than 6 degrees. T-Scan COF showed how in healthy group control there was never a difference of COF greater than 5%. In no healthy group the difference were greater than 5% Pjoint sound than the balance side P<0.001. sEMG show how in TMID patients maximum masseter activation is always lower than maximum masseter activation of healthy subjects P<0.001. Neuro occlusal clinical evaluation (NOE) in TMID patients is supported by instrumental evaluation.

  9. Microcomputer Network for Computerized Adaptive Testing (CAT)

    Science.gov (United States)

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  10. Computed tomographic brain scanning in the diagnosis of metastatic neoplasms

    International Nuclear Information System (INIS)

    Ringelstein, E.B.; Zeumer, H.; Hacke, W.; Keulers, P.

    1981-01-01

    Clinical investigations and computed brain scanning were done in 305 patients with primary extracerebral malignant tumours. One third of the patients had cerebral metastases. In most patients with brain metastases extracerebral secondary tumours were known already. Silent brain metastases were present in only 0.6% of all investigated tumour patients. All other patients had either objective neurologic-psychiatric defects or at least symptoms (headache, vomiting). Use of cranial computed tomography in all tumour patients as a pure screening method is thus not justified. The indication for the investigation is dependent on the clinical symptomatology. However, not only objective neurologic-psychiatric defects must be taken into account, but also occurrence of new symptoms. (orig.) [de

  11. Computerized system for measuring cerebral metabolism

    International Nuclear Information System (INIS)

    McGlone, J.S.; Hibbard, L.S.; Hawkins, R.A.; Kasturi, R.

    1987-01-01

    A computerized stereotactic measurement system for evaluating rat brain metabolism was developed to utilize the large amount of data generated by quantitative autoradiography. Conventional methods of measurement only analyze a small percent of these data because these methods are limited by instrument design and the subjectiveness of the investigator. However, a computerized system allows digital images to be analyzed by placing data at their appropriate three-dimensional stereotactic coordinates. The system automatically registers experimental data to a standard three-dimensional image using alignment, scaling, and matching operations. Metabolic activity in different neuronal structures is then measured by generating digital masks and superimposing them on to experimental data. Several experimental data sets were evaluated and it was noticed that the structures measured by the computerized system, had in general, lower metabolic activity than manual measurements had indicated. This was expected because the computerized system measured the structure over its volume while the manual readings were taken from the most active metabolic area of a particular structure

  12. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Wilkinson, N.A.; Rogers, J.G.; Atkins, M.S.

    1989-01-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. the data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition system. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events which are 64 bits wide

  13. Analysis and databasing software for integrated tomographic gamma scanner (TGS) and passive-active neutron (PAN) assay systems

    International Nuclear Information System (INIS)

    Estep, R.J.; Melton, S.G.; Buenafe, C.

    2000-01-01

    The CTEN-FIT program, written for Windows 9x/NT in C++,performs databasing and analysis of combined thermal/epithermal neutron (CTEN) passive and active neutron assay data and integrates that with isotopics results and gamma-ray data from methods such as tomographic gamma scanning (TGS). The binary database is reflected in a companion Excel database that allows extensive customization via Visual Basic for Applications macros. Automated analysis options make the analysis of the data transparent to the assay system operator. Various record browsers and information displays simplify record keeping tasks

  14. CT-scanning in otolaryngology, 2

    International Nuclear Information System (INIS)

    Kusakari, Jun; Endo, Satomi; Hara, Akira

    1982-01-01

    Combined computerized tomography-sialography was performed in 28 patients with parotid tumors. Sialography was performed in the usual fashion. After confirming the presence of the contrast material within the parotid gland by X-ray, 4 to 5 scannings were done at the width of 10 mm below Repid's base line. With this procedure, the parotid gland was clearly demonstrated and the location of the tumor was shown as a shadow defect. Although the nature of the tumor, especially whether it was malignant or benign was difficult to predict, the CT-findings regarding the size and location of the tumor were completely coincident with the operative findings in all the cases. Accurate appraisal of the relation between the tumor and the facial nerve was possible in all but two cases. The preoperative information obtained from CT-scanning is extremely useful in the case of parotid tumor surgery. (author)

  15. Computed tomographic features of 23 sporadic cases with Legionella pneumophila pneumonia

    International Nuclear Information System (INIS)

    Yu Hui; Higa, Futoshi; Hibiya, Kenji; Furugen, Makoto; Sato, Yoko; Shinzato, Takashi; Haranaga, Shusaku; Yara, Satomi; Tateyama, Masao; Fujita, Jiro; Li, Huiping

    2010-01-01

    Objective: To describe the chest computed tomographic (CT) findings of Legionella pneumophila pneumonia. Methods: CT scans obtained from 23 sporadic cases of L. pneumophila pneumonia were retrospectively reviewed. Chest CT findings were analyzed with regard to the patterns and distributions of pulmonary abnormalities. We also analyzed the histopathology of lungs from guinea pigs with experimentally induced L. pneumophila pneumonia. Results: Consolidation and ground-glass opacity (GGO) were the main findings of CT scans in L. pneumophila pneumonia. The distribution of opacities was categorized as non-segmental (n = 20) and segmental (n = 4). Non-segmental distribution may follow an onset of segmental distribution. Pleural effusion was observed in 14 (58.3%) patients, of which 13 were accompanied with non-segmental distribution. Abscess formation was observed in only one immunocompromised patient. In the animal pneumonia model, the lesions comprised of terminal bronchioles, alveolar spaces, and interstitia. Small bacilli were observed to be contained by many macrophages within the alveoli. Conclusion: Non-segmental distribution was significantly more frequent than segmental distribution in L. pneumophila pneumonia. It is possible that L. pneumophila infection initially results in segmental pneumonia, which progresses to typical non-segmental distribution.

  16. Computed tomographic features of 23 sporadic cases with Legionella pneumophila pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hui [Department of Respiratory Diseases, Shanghai Pneumology Hospital, Tongji University, Shanghai (China); Higa, Futoshi; Hibiya, Kenji; Furugen, Makoto [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Sato, Yoko [Tomishiro Chuo Hospital, Okinawa (Japan); Shinzato, Takashi [Nakagami General Hospital, Okinawa (Japan); Haranaga, Shusaku; Yara, Satomi; Tateyama, Masao [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Fujita, Jiro, E-mail: fujita@med.u-ryukyu.ac.j [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Li, Huiping [Department of Respiratory Diseases, Shanghai Pneumology Hospital, Tongji University, Shanghai (China)

    2010-06-15

    Objective: To describe the chest computed tomographic (CT) findings of Legionella pneumophila pneumonia. Methods: CT scans obtained from 23 sporadic cases of L. pneumophila pneumonia were retrospectively reviewed. Chest CT findings were analyzed with regard to the patterns and distributions of pulmonary abnormalities. We also analyzed the histopathology of lungs from guinea pigs with experimentally induced L. pneumophila pneumonia. Results: Consolidation and ground-glass opacity (GGO) were the main findings of CT scans in L. pneumophila pneumonia. The distribution of opacities was categorized as non-segmental (n = 20) and segmental (n = 4). Non-segmental distribution may follow an onset of segmental distribution. Pleural effusion was observed in 14 (58.3%) patients, of which 13 were accompanied with non-segmental distribution. Abscess formation was observed in only one immunocompromised patient. In the animal pneumonia model, the lesions comprised of terminal bronchioles, alveolar spaces, and interstitia. Small bacilli were observed to be contained by many macrophages within the alveoli. Conclusion: Non-segmental distribution was significantly more frequent than segmental distribution in L. pneumophila pneumonia. It is possible that L. pneumophila infection initially results in segmental pneumonia, which progresses to typical non-segmental distribution.

  17. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  18. Computerized reactor monitor and control for research reactors

    International Nuclear Information System (INIS)

    Buerger, L.; Vegh, E.

    1981-09-01

    The computerized process control system developed in the Central Research Institute for Physics, Budapest, Hungary, is described together with its special applications at research reactors. The nuclear power of the Hungarian research reactor is controlled by this computerized system, too, while in Lybia many interesting reactor-hpysical calculations are built into the computerized monitor system. (author)

  19. Construction of a positron emission tomograph with 2.4 mm detectors

    International Nuclear Information System (INIS)

    McIntyre, J.A.; Sprosst, R.L.; Wang, K.

    1986-01-01

    One-quarter of one ring of a positron tomograph has been constructed. The positron annihilation gamma rays are detected by polished plastic scintillators which direct scintillation light by internal reflection to optical fibers for transmission to the photo-multiplier tubes. By viewing each scintillator with four sets of optical fibers, the number of photomultipliers required for an eight ring tomograph with 1024 detectors per ring (2.4 mm wide detectors) can be reduced from 8192 to 288, and the cost of the tomograph reduced accordingly

  20. Expediting model-based optoacoustic reconstructions with tomographic symmetries

    International Nuclear Information System (INIS)

    Lutzweiler, Christian; Deán-Ben, Xosé Luís; Razansky, Daniel

    2014-01-01

    Purpose: Image quantification in optoacoustic tomography implies the use of accurate forward models of excitation, propagation, and detection of optoacoustic signals while inversions with high spatial resolution usually involve very large matrices, leading to unreasonably long computation times. The development of fast and memory efficient model-based approaches represents then an important challenge to advance on the quantitative and dynamic imaging capabilities of tomographic optoacoustic imaging. Methods: Herein, a method for simplification and acceleration of model-based inversions, relying on inherent symmetries present in common tomographic acquisition geometries, has been introduced. The method is showcased for the case of cylindrical symmetries by using polar image discretization of the time-domain optoacoustic forward model combined with efficient storage and inversion strategies. Results: The suggested methodology is shown to render fast and accurate model-based inversions in both numerical simulations andpost mortem small animal experiments. In case of a full-view detection scheme, the memory requirements are reduced by one order of magnitude while high-resolution reconstructions are achieved at video rate. Conclusions: By considering the rotational symmetry present in many tomographic optoacoustic imaging systems, the proposed methodology allows exploiting the advantages of model-based algorithms with feasible computational requirements and fast reconstruction times, so that its convenience and general applicability in optoacoustic imaging systems with tomographic symmetries is anticipated

  1. Experience of computed tomographic myelography and discography in cervical problem

    Energy Technology Data Exchange (ETDEWEB)

    Nakatani, Shigeru; Yamamoto, Masayuki; Uratsuji, Masaaki; Suzuki, Kunio; Matsui, Eigo [Hyogo Prefectural Awaji Hospital, Sumoto, Hyogo (Japan); Kurihara, Akira

    1983-06-01

    CTM (computed tomographic myelography) was performed on 15 cases of cervical lesions, and on 5 of them, CTD (computed tomographic discography) was also made. CTM revealed the intervertebral state, and in combination with CTD, providing more accurate information. The combined method of CTM and CTD was useful for soft disc herniation.

  2. Middle east respiratory syndrome-corona virus infection: A case report of sieral computed tomographic findings in a young male patient

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Won Jin; Lee, Ki Nam; Kang, Eun Ju; Lee, Hyuck [Dong A University Hospital, Busan (Korea, Republic of)

    2016-02-15

    Radiologic findings of Middle East respiratory syndrome (MERS), a novel coronavirus infection, have been rarely reported. We report a 30-year-old male presented with fever, abdominal pain, and diarrhea, who was diagnosed with MERS. A chest computed tomographic scan revealed rapidly developed multifocal nodular consolidations with ground-glass opacity halo and mixed consolidation, mainly in the dependent and peripheral areas. After treatment, follow-up imaging showed that these abnormalities markedly decreased but fibrotic changes developed.

  3. Tomographic findings of acute pulmonary toxoplasmosis in immunocompetent patients.

    Science.gov (United States)

    de Souza Giassi, Karina; Costa, Andre Nathan; Apanavicius, Andre; Teixeira, Fernando Bin; Fernandes, Caio Julio Cesar; Helito, Alfredo Salim; Kairalla, Ronaldo Adib

    2014-11-25

    Toxoplasmosis is one of the most common human zoonosis, and is generally benign in most of the individuals. Pulmonary involvement is common in immunocompromised subjects, but very rare in immunocompetents and there are scarce reports of tomographic findings in the literature. The aim of the study is to describe three immunocompetent patients diagnosed with acute pulmonary toxoplasmosis and their respective thoracic tomographic findings. Acute toxoplasmosis was diagnosed according to the results of serological tests suggestive of recent primary infection and the absence of an alternative etiology. From 2009 to 2013, three patients were diagnosed with acute respiratory failure secondary to acute toxoplasmosis. The patients were two female and one male, and were 38, 56 and 36 years old. Similarly they presented a two-week febrile illness and progressive dyspnea before admission. Laboratory tests demonstrated lymphocytosis, slight changes in liver enzymes and high inflammatory markers. Tomographic findings were bilateral smooth septal and peribronchovascular thickening (100%), ground-glass opacities (100%), atelectasis (33%), random nodules (33%), lymph node enlargement (33%) and pleural effusion (66%). All the patients improved their symptoms after treatment, and complete resolution of tomographic findings were found in the followup. These cases provide a unique description of the presentation and evolution of pulmonary tomographic manifestations of toxoplasmosis in immunocompetent patients. Toxoplasma pneumonia manifests with fever, dyspnea and a non-productive cough that may result in respiratory failure. In animal models, changes were described as interstitial pneumonitis with focal infiltrates of neutrophils that can finally evolve into a pattern of diffuse alveolar damage with focal necrosis. The tomographic findings are characterized as ground glass opacities, smooth septal and marked peribronchovascular thickening; and may mimic pulmonary congestion

  4. Measurement of mesothelioma on thoracic CT scans: A comparison of manual and computer-assisted techniques

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Oxnard, Geoffrey R.; MacMahon, Heber; Vogelzang, Nicholas J.; Kindler, Hedy L.; Kocherginsky, Masha; Starkey, Adam

    2004-01-01

    Our purpose in this study was to evaluate the variability of manual mesothelioma tumor thickness measurements in computed tomography (CT) scans and to assess the relative performance of six computerized measurement algorithms. The CT scans of 22 patients with malignant pleural mesothelioma were collected. In each scan, an initial observer identified up to three sites in each of three CT sections at which tumor thickness measurements were to be made. At each site, five observers manually measured tumor thickness through a computer interface. Three observers repeated these measurements during three separate sessions. Inter- and intra-observer variability in the manual measurement of tumor thickness was assessed. Six automated measurement algorithms were developed based on the geometric relationship between a specified measurement site and the automatically extracted lung regions. Computer-generated measurements were compared with manual measurements. The tumor thickness measurements of different observers were highly correlated (r≥0.99); however, the 95% limits of agreement for relative inter-observer difference spanned a range of 30%. Tumor thickness measurements generated by the computer algorithms also correlated highly with the average of observer measurements (r≥0.93). We have developed computerized techniques for the measurement of mesothelioma tumor thickness in CT scans. These techniques achieved varying levels of agreement with measurements made by human observers

  5. Development of a X-ray micro-tomograph and its application to reservoir rocks characterization

    International Nuclear Information System (INIS)

    Ferreira de Paiva, R.

    1995-10-01

    We describe the construction and application to studies in three dimensions of a laboratory micro-tomograph for the characterisation of heterogeneous solids at the scale of a few microns. The system is based on an electron microprobe and a two dimensional X-ray detector. The use of a low beam divergence for image acquisition allows use of simple and rapid reconstruction software whilst retaining reasonable acquisition times. Spatial resolutions of better than 3 microns in radiography and 10 microns in tomography are obtained. The applications of microtomography in the petroleum industry are illustrated by the study of fibre orientation in polymer composites, of the distribution of minerals and pore space in reservoir rocks, and of the interaction of salt water with a model porous medium. A correction for X-ray beam hardening is described and used to obtain improved discrimination of the phases present in the sample. In the case of a North Sea reservoir rock we show the possibility to distinguish quartz, feldspar and in certain zone kaolinite. The representativeness of the tomographic reconstruction is demonstrated by comparing the surface of the reconstructed specimen with corresponding images obtained in scanning electron microscopy. (author). 58 refs., 10 tabs., 71 photos

  6. Computerized tomography of the pancreas

    International Nuclear Information System (INIS)

    Dondelinger, R.; Campos, R.O.; Lamarque, J.L.

    1979-01-01

    Pancreatic anatomy is briefly reviewed. Tomographic images from normal pancreas and from pathological states (different kinds of pancreatitis; pancreatic tumors) of this organ are discussed. (M.A.) [pt

  7. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer

    2004-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  8. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer S

    2005-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  9. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  10. Feasibility of F-18-FDG PET/CT scan in abdominopelvic regions

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2008-01-01

    F-18-2-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/CT scan, which simultaneously provides metabolic function and morphology on the same tomographic section, is being the key imaging modality for diagnosis and treatment strategy of makignancies in various organs. FDG PET/CT scanning of the whole body beneficially allows the assessment of primary tumor and regional lymph nodes, and distant metastases and co-existed benign/other malignant lesions, as ''one stop shopping'' fashion. This technique contributes to the selection of the optimal treatment in individual patients, and also can predict histopathologic response to treatment and postoperative/post chemo-radiation therapeutic prognosis. In this paper, we describe the fundamental knowledge required for accurate interpretation of FDG PET/CT scan, and review the utility of this technique for diagnosis and treatment strategy of makignancies in abdominal and pelvic regions. (author)

  11. A novel scanning interferometer for two-dimensional plasma density measurements

    International Nuclear Information System (INIS)

    Howard, J.

    1989-01-01

    A novel multichannel scanning interferometer designed for tomographically inferring contours of electron density in magnetically confined plasmas is described. The scanning element is a multi-sectored blazed rotating grating. The diffracted beam emerges at a different angle from each sector giving rise to a fan array of discrete beams for each rotation of the grating. Signals from the probing chords are multiplexed in time enabling the use of a single detecting element for the extraction of many channels of line integrated density information. An air turbine driven grating wheel assembly has been fabricated and initial tests performed. The proposed interferometer is to be installed on the H-1 helical axis stellarator currently under construction at the Australian National University. 16 refs., 12 figs

  12. A Novel Quantitative Computed Tomographic Analysis Suggests How Sirolimus Stabilizes Progressive Air Trapping in Lymphangioleiomyomatosis.

    Science.gov (United States)

    Argula, Rahul G; Kokosi, Maria; Lo, Pechin; Kim, Hyun J; Ravenel, James G; Meyer, Cristopher; Goldin, Jonathan; Lee, Hye-Seung; Strange, Charlie; McCormack, Francis X

    2016-03-01

    The Multicenter International Lymphangioleiomyomatosis Efficacy and Safety of Sirolimus (MILES) trial demonstrated that sirolimus stabilized lung function and improved measures of functional performance and quality of life in patients with lymphangioleiomyomatosis. The physiologic mechanisms of these beneficial actions of sirolimus are incompletely understood. To prospectively determine the longitudinal computed tomographic lung imaging correlates of lung function change in MILES patients treated with placebo or sirolimus. We determined the baseline to 12-month change in computed tomographic image-derived lung volumes and the volume of the lung occupied by cysts in the 31 MILES participants (17 in sirolimus group, 14 in placebo group) with baseline and 12-month scans. There was a trend toward an increase in median expiratory cyst volume percentage in the placebo group and a reduction in the sirolimus group (+2.68% vs. +0.97%, respectively; P = 0.10). The computed tomographic image-derived residual volume and the ratio of residual volume to total lung capacity increased more in the placebo group than in the sirolimus group (+214.4 ml vs. +2.9 ml [P = 0.054] and +0.05 ml vs. -0.01 ml [P = 0.0498], respectively). A Markov transition chain analysis of respiratory cycle cyst volume changes revealed greater dynamic variation in the sirolimus group than in the placebo group at the 12-month time point. Collectively, these data suggest that sirolimus attenuates progressive gas trapping in lymphangioleiomyomatosis, consistent with a beneficial effect of the drug on airflow obstruction. We speculate that a reduction in lymphangioleiomyomatosis cell burden around small airways and cyst walls alleviates progressive airflow limitation and facilitates cyst emptying.

  13. Radio tomographic imaging of sporadic-E layers during SEEK-2

    Directory of Open Access Journals (Sweden)

    P. A. Bernhardt

    2005-10-01

    Full Text Available During the SEEK-2 Rocket Campaign in August 2002, a Dual Band Beacon (DBB transmitting to Ground Receivers provided unique data on E-Region electron densities. Information from two rocket beacons and four ground receivers yielded multiple samples of E-region horizontal and vertical variations. The radio beacon measurements were made at four sites (Uchinoura, Tarumizu, Tanegashima, Takazaki in Japan for two rockets (S310-31 and S310-32 launched by the Institute of Space and Aeronautical Science (ISAS. Analysis was completed for four sets of beacon data to provide electron density images of sporadic-E layers. Signals from the two-frequency beacons on the SEEK-2 rockets were processed to yield total electron content (TEC data that was converted into electron density measurements. Wide variations in layer structures were detected. These included horizontal sporadic-E variations, vertical profiles of double, single, and weak layers. The radio beacon measurements were shown to be in agreement with the in-situ SEEK-2 sensors. The first tomographic image of a sporadic-E layer was produced from the data. The rocket beacon technique was shown to be an excellent tool to study sporadic-E layers because absolute TEC accuracy of 0.01 TEC Units can be easily obtained and, with proper receiver placement, electron density images can be produced using computerized ionospheric tomography with better than 1km horizontal and vertical resolution. Keywords. Ionospheric irregularities – Instruments and techniques – Mid-latitude ionosphere

  14. Computed tomographic findings of intracerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo; Lee, Sun Wha; Kim, Ho Kyun; Ahn, Chi Yul [School of Medicine, Kyung-Hee University, Seoul (Korea, Republic of)

    1980-12-15

    Cysticercosis is a parasitic disease in which man serves as the intermediate host of Taenia Solium, the pork tapeworm. The computed tomographic findings of 25 cases of intracerebral cysticercosis proven by pathologic and/or clinical findings during past 2 years were analysed. The results were as follows; 1. The sex was 19 males and 6 females, and 56 percent of the patients were seen in fourth and fifth decades. The most common symptom was epilepsy (72%). 2. The C. T. findings in precontrast study were varied; such as ill defined low density (48%), cystic low density (20%), dilated ventricles (20%), ill defined low density with isodense nodule (18%), cystic low density with isodense mural nodule (12%) and calcification (8%). 3. The areas of involvement were 20 cases (80%) of parenchymal form, 3 cases (12%) of ventricular form and 2 cases (8%) of mixed form. 4. The contrast-enhanced 13 cases were 5 nodular, 5 ring or rim-like and 3 mixed type enhancements, while 12 cases were not enhanced. 5. C.T. scan demonstrated more precise location and extents of cerebral cysticercosis, especially in parenchymal form. It was considered to be important in determination of surgical feasibility and its approach.

  15. Computed tomographic findings of cerebral paragonimiasis

    International Nuclear Information System (INIS)

    Sung, Nak Kwan; Nam, Kyung Jin; Park, Churl Min; Eun, Chung Kie; Lee, Sun Wha

    1983-01-01

    Paragonimiasis is widely distributed in Far East and Southeast Asia, particularly in Korea. The central nervous system is the most frequent location for paragonimiasis outside the lungs. We analyzed the computed tomographic findings of 17 cases which were diagnosed pathologically and clinically as cerebral paragonimiasis. The results were as follows: 1. The ratio of male to female was 10 : 7 and about 88% of cases were under the age of 40 years. 2. The common locations of cerebral paragonimiasis were the occipital (12 cases) and temporal (11 cases) lobes. 3. Precontrast CT findings of cerebral paragonimiasis were low density with calcifications in 6 cases, low and isodensities in 4 cases, mixed densities in 3 cases, only low density in 2 cases and only calcification in 2 cases. Hydrocephalus (7 cases), mass effect (6 cases), atrophic change (6 cases) and cyst formation (3 cases) were associated. 4. The shape of calcifications in CT scan were soap-bubble or ring in 6 cases, nodular or oval in 6 cases, stipple in 4 cases and amorphous conglomerated in 2 cases. 5. The contrast -enhanced 8 cases were 5 ring or rim like, 2 nodular and 1 irregular enhancements, while 9 cases were not enhanced

  16. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  17. Preparation and tomographic reconstruction of an arbitrary single-photon path qubit

    International Nuclear Information System (INIS)

    Baek, So-Young; Kim, Yoon-Ho

    2011-01-01

    We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. The arbitrary single-photon path qubit is prepared losslessly by passing the heralded single-photon state from spontaneous parametric down-conversion through variable beam splitter. Quantum state tomography of the single-photon path qubit is implemented by introducing path-projection measurements based on the first-order single-photon quantum interference. Using the state preparation and path-projection measurements methods for the single-photon path qubit, we demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity. -- Highlights: → We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. → We implement path-projection measurements based on the first-order single-photon quantum interference. → We demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity.

  18. CT of multiple sclerosis: reassessment of delayed scanning with high doses of contrast material

    International Nuclear Information System (INIS)

    Spiegel, S.M.; Vinuela, F.; Fox, A.J.; Pelz, D.M.

    1985-01-01

    A prospective study involving 87 patients was carried out to evaluate the necessity for a high dose of contrast material in addition to delayed computed tomographic (CT) scanning for optimal detection of the lesions of multiple sclerosis in the brain. In patients with either clinically definite multiple sclerosis or laboratory-supported definite multiple sclerosis, CT scans were obtained with a uniform protocol. Lesions consistent with multiple sclerosis were demonstrated on the second scan in 54 patients. In 36 of these 54 patients, the high-dose delayed scan added information. These results are quite similar to those of a previous study from this institution using different patients, in whom the second scan was obtained immediately after the bolus injection of contrast material containing 40 g of organically bound iodine. The lack of real difference in the results of the two studies indicate that the increased dose, not just the delay in scanning, is necessary for a proper study

  19. Computerized tomography of pelvic osteomyelitis in patients with spinal cord injuries

    International Nuclear Information System (INIS)

    Firooznia, H.; Rafii, M.; Golimbu, C.; Sokolow, J.

    1983-01-01

    Computerized tomography (CT) was performed in 19 patients with spinal cord injury (SCI) who had large pressure sores and in whom other complications were suspected. CT detected the depth, extent, and degree of undermining of the edges of the pressure sores in 19 of 27 lesions. Conventional radiography detected four cases of pelvic osteomyelitis. CT detected eight additional cases of pelvic osteomyelitis, as well as eight clinically unsuspected peripelvic and intrapelvic abscesses. Technetium-99m bone scanning was not very helpful because of localization in chronic proliferative changes of bone and widespread foci of myositis ossificans, as well as in osteomyelitis. Gallium-67 scanning detected only one of six abscesses. It was not very helpful because of confusion of abscess and osteomyelitis with intense soft tissue swelling and cellulitis, which are often associated with pressure sores in patients with chronic SCI. CT was found to be, by far, the modality of choice for detection of pelvic osteomyelitis and abscess in patients with SCI

  20. New techniques for resolution enhancement of 3D x-ray tomographic imaging from incomplete data

    International Nuclear Information System (INIS)

    Vengrinovich, V.; Zolotarev, S.; Denkevich, Y.; Tillack, G.-R.

    2004-01-01

    Accurate evaluation of dimensions directly from tomographic images, restored from only few x-ray projections, made in a limited observation sector, is considered exploiting pipes wall thickness assessment like a typical example. Both experiments and simulations are used to extract main errors sources. It is taken from as known, that neglecting of the scattered radiation and beam hardening effects results in image blurring, strong artifacts and finally inaccurate sizing. The computerized technique is developed to simulate the contribution of scattered radiation and beam hardening for the purpose of their further extraction from projected data. After those accompanying effects extraction the iterative Bayesian techniques are applied to reconstruct images from the projections, using volumetric and/or shell representation of the objects like pipes. The achieved error of virtual pipe wall thickness assessment from 3D images can be as small as 300μk comparing to 1mm provided by modern techniques. Finally the conclusion was drawn that standard projection techniques using X- or Gamma rays in combination with X-ray film or imaging plates can be applied for the data acquisition to reconstruct finally wall thickness profiles in an in-field environment. (author)

  1. Simultaneous emission and transmission scanning in positron emission tomography

    International Nuclear Information System (INIS)

    Satoh, Tomohiko; Tanaka, Kazumi; Kitamura, Keishi; Amano, Masaharu; Miura, Shuichi

    2001-01-01

    Examination by PET (positron emission tomography) scanning, following the dosage of 2-deoxy- 18 F fluoro-D-glucose (FDG), is positively utilized for the diagnosis of cancers, rather than for the purpose of studies. This is because the examination by FDG-PET (PET scanning following the dosage of FDG) ensures higher efficiency in discrimination of cancers, than conventional CT and PET. The method of whole body scanning by PET scanning following the dosage of FDG is effectively utilized not only for discrimination cancers, but also for determining the degree of malignancy of tumors and evaluating the methods of treatment of cancers. In conventional methods for examining the degree of malignancy of tumors and evaluating the methods of cancer treatment, it is necessary to correct for the gamma-ray attenuation, which requires a longer time for examination, increasing the physical and psychological pains of the patients. We have installed the simultaneous emission and transmission scanning capability into the HEADTOME-V of the Shimadzu SET-2000W Series positron emission tomographic scanning instruments, to establish an instrument that permits FDG-PET whole body scanning in actual clinical fields, with minimized physical and psychological pains of patients concerned, yet ensuring an outstandingly high examination efficiency. This report also presents some data obtained by this newly developed instrument and those obtained in practical applications. (author)

  2. Computed tomographic findings of intracranial gliosis

    International Nuclear Information System (INIS)

    Weisberg, L.

    1981-01-01

    The clinical and computed tomographic (CT) findings in eight patients with pathological evidence of cerebral gliosis are analyzed. CT findings do not permit differentiation of gliosis from other neoplastic and non-neoplastic conditions. (orig.)

  3. Method and apparatus for scanning x-ray tomography

    International Nuclear Information System (INIS)

    Albert, R.D.

    1988-01-01

    In a method of producing a tomographic image of a subject that includes the steps of generating X-rays at a moving origin point by directing a charged particle beam to a target surface, deflecting the charged particle beam to travel the origin point through a predetermined raster scan at the surface, detecting variations of X-ray intensity during the course of the raster scan at spaced apart detection points situated at the opposite side of the subject from the origin point, generating a first sequence of data values that is indicative of variations of X-ray intensity at a first of the detection points at successive times during the course of the raster scan and generating at least a second sequence of data values that is indicative of variations of X-ray intensity at a second of the detection points at successive times during the course of the same raster scan, the improvement is described comprising: combining successive individual data values of the first sequence that are generated by X-rays from successive particular locations in the raster scan with at least individual data values of the second sequence that are generated by X-rays from predetermined successive different locations in the same raster scan in order to produce a composite sequence of data values, and producing an image corresponding to at least a portion of the raster scan which depicts variations of the magnitude of successive data values of the composite sequence

  4. Study of effect of different CT scanning protocols on HU variation and their impact on TPS calculations

    International Nuclear Information System (INIS)

    Mahur, Mamta; Sharma, Richa; Sasindaran, M.; Singh, Anshu; Gedam, Varsha; Negi, P.S.; Grover, R.K.

    2016-01-01

    Computer tomographic (CT) scans are used to correct for tissue inhomogeneties in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and relative electron densities, which is the basic input for radiotherapy planning systems which consider tissue heterogeneities. The purpose of this study is to investigate the influence of different CT scan parameters (kVp, mAs) on uniformity of CT numbers versus relative electron density (HURED) curves and their different dosimetric impact

  5. Utility of cervical spinal and abdominal computed tomography in diagnosing occult pneumothorax in patients with blunt trauma: Computed tomographic imaging protocol matters.

    Science.gov (United States)

    Akoglu, Haldun; Akoglu, Ebru Unal; Evman, Serdar; Akoglu, Tayfun; Denizbasi, Arzu; Guneysel, Ozlem; Onur, Ozge; Onur, Ender

    2012-10-01

    Small pneumothoraces (PXs), which are not initially recognized with a chest x-ray film and diagnosed by a thoracic computed tomography (CT), are described as occult PX (OCPX). The objective of this study was to evaluate cervival spine (C-spine) and abdominal CT (ACT) for diagnosing OCPX and overt PX (OVPX). All patients with blunt trauma who presented consecutively to the emergency department during a 26-months period were included. Among all the chest CTs (CCTs) (6,155 patients) conducted during that period, 254 scans were confirmed to have a true PX. The findings in their C-spine CT and ACT were compared with the findings in CCTs. Among these patients, 254 had a diagnosis of PX confirmed with CCT. OCPXs were identified on the chest computed tomographic scan of 128 patients (70.3%), whereas OVPXs were evident in 54 patients (29.7%). Computed tomographic imaging of the C-spine was performed in 74% of patients with OCPX and 66.7% of patients with OVPX trauma. Only 45 (35.2%) cases of OCPX and 42 (77.8%) cases of OVPX were detected by C-spine CT. ACT was performed in almost all patients, and 121 (95.3%) of 127 of these correctly identified an existing OCPX. Sensitivity of C-spine CT and ACT was 35.1% and 96.5%, respectively; specificity was 100% and 100%, respectively. Almost all OCPXs, regardless of intrathoracic location, could be detected by ACT or by combining C-spine and abdominal computed tomographic screening for patients. If the junction of the first and second vertebra is used as the caudad extent, C-spine CT does not have sufficient power to diagnose more than a third of the cases. Diagnostic study, level III.

  6. Original circuitry for TOHR tomograph

    International Nuclear Information System (INIS)

    Cuzon, J.C.; Pinot, L.

    1999-01-01

    Having industrialization in mind, a specific electronics for a high resolution tomograph is designed out of the usual standards of nuclear physics. All the information are converted in the time domain and a fast processor, in front of the data acquisition, carries out the time and energy coincidences. (authors)

  7. Tomographic PIV: principles and practice

    International Nuclear Information System (INIS)

    Scarano, F

    2013-01-01

    A survey is given of the major developments in three-dimensional velocity field measurements using the tomographic particle image velocimetry (PIV) technique. The appearance of tomo-PIV dates back seven years from the present review (Elsinga et al 2005a 6th Int. Symp. PIV (Pasadena, CA)) and this approach has rapidly spread as a versatile, robust and accurate technique to investigate three-dimensional flows (Arroyo and Hinsch 2008 Topics in Applied Physics vol 112 ed A Schröder and C E Willert (Berlin: Springer) pp 127–54) and turbulence physics in particular. A considerable number of applications have been achieved over a wide range of flow problems, which requires the current status and capabilities of tomographic PIV to be reviewed. The fundamental aspects of the technique are discussed beginning from hardware considerations for volume illumination, imaging systems, their configurations and system calibration. The data processing aspects are of uppermost importance: image pre-processing, 3D object reconstruction and particle motion analysis are presented with their fundamental aspects along with the most advanced approaches. Reconstruction and cross-correlation algorithms, attaining higher measurement precision, spatial resolution or higher computational efficiency, are also discussed. The exploitation of 3D and time-resolved (4D) tomographic PIV data includes the evaluation of flow field pressure on the basis of the flow governing equation. The discussion also covers a-posteriori error analysis techniques. The most relevant applications of tomo-PIV in fluid mechanics are surveyed, covering experiments in air and water flows. In measurements in flow regimes from low-speed to supersonic, most emphasis is given to the complex 3D organization of turbulent coherent structures. (topical review)

  8. Effective Heart Disease Detection Based on Quantitative Computerized Traditional Chinese Medicine Using Representation Based Classifiers

    Directory of Open Access Journals (Sweden)

    Ting Shu

    2017-01-01

    Full Text Available At present, heart disease is the number one cause of death worldwide. Traditionally, heart disease is commonly detected using blood tests, electrocardiogram, cardiac computerized tomography scan, cardiac magnetic resonance imaging, and so on. However, these traditional diagnostic methods are time consuming and/or invasive. In this paper, we propose an effective noninvasive computerized method based on facial images to quantitatively detect heart disease. Specifically, facial key block color features are extracted from facial images and analyzed using the Probabilistic Collaborative Representation Based Classifier. The idea of facial key block color analysis is founded in Traditional Chinese Medicine. A new dataset consisting of 581 heart disease and 581 healthy samples was experimented by the proposed method. In order to optimize the Probabilistic Collaborative Representation Based Classifier, an analysis of its parameters was performed. According to the experimental results, the proposed method obtains the highest accuracy compared with other classifiers and is proven to be effective at heart disease detection.

  9. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Atkins, M.S.; Wilkinson, N.A.; Rogers, J.G.

    1988-11-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. The data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition systems. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events per second for raw events which are 64 bits wide. Real-time data acquisition and pre-processing requirements can be met by about forty 20 MHz Motorola 68020/68881 processors

  10. Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.

    Science.gov (United States)

    Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A

    2011-08-01

    To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.

  11. Correction of ring artifacts in X-ray tomographic images

    DEFF Research Database (Denmark)

    Lyckegaard, Allan; Johnson, G.; Tafforeau, P.

    2011-01-01

    Ring artifacts are systematic intensity distortions located on concentric circles in reconstructed tomographic X-ray images. When using X-ray tomography to study for instance low-contrast grain boundaries in metals it is crucial to correct for the ring artifacts in the images as they may have...... the same intensity level as the grain boundaries and thus make it impossible to perform grain segmentation. This paper describes an implementation of a method for correcting the ring artifacts in tomographic X-ray images of simple objects such as metal samples where the object and the background...... are separable. The method is implemented in Matlab, it works with very little user interaction and may run in parallel on a cluster if applied to a whole stack of images. The strength and robustness of the method implemented will be demonstrated on three tomographic X-ray data sets: a mono-phase β...

  12. Indirect computerized tomography sign of chronic subdural hematoma demonstrated in the posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Machi, Takao; Fukui, Masashi; Maeyama, Ryutaro; Takaki, Tosuke; Yoshiura, Shogo; Kamoi, Itsuma

    1985-03-01

    In cases of chronic subdural hematoma (CSH), brain computerized tomography (CT) scans frequently disclose a low density band in the posterior fossa (LDBP) between the lateral margin of the cerebellum and the adjacent petrous bone/tentorium cerebelli. Out of 121 cases of CSH, 56 (46%) showed the LDBP. The LDBP was mostly ipsilateral to the side of the CSH or bilateral. The frequency of the LDBP had no correlation with the severity of the cerebral midline shift or the thickness of the hematoma. As normal controls, CT scans of 257 cases in which no organic lesions were detected were used. Also 30 cases with dementing diseases, 2 cases with spinocerebellar degeneration and 428 cases of other neurological diseases such as head trauma other than CSH, brain tumor, cerebrovascular disease etc. were studied as disease controls. The incidence of the LDBP in both controls was significantly lower than in CSH. Therefore, the LDBP in cases of CSH was considered to be a significant associated finding of CT scans. The mechanism of the LDBP is discussed.

  13. Optimization of protocol in computerized tomography scans of children's chest

    International Nuclear Information System (INIS)

    Lima, L.T.A.; Roberto, W. dos S.; Mourão Filho, A.P.

    2017-01-01

    The diffusion of the Computed Tomography (CT) has promoted a significant increase of the dose absorbed by patients. This technique showed a high growth as a result of clinical cases of medical emergencies, neoplasia and pediatric traumas. The risks of stochastic effects are greater for children due to tissue radiosensitivity coupled with longer life expectancy. In the present work, a cylindrical simulator was used, representing an adult thorax made of polymethylmethacrylate (PMMA), and a second simulator object of the same material was developed in oblong format including the axillary regions, based on the dimensions of the patient's thorax one-year-old pediatric population. The scanning on the adult simulator object was performed with the chest radiograph diagnostic service with a 120 kV supply voltage and in the pediatric simulator object were performed optimized scans with 120, 100 and 80 kV. This work compared the dose variation absorbed by the pediatric simulator object mentioned by the change in the tube supply voltage

  14. Histologic and tomographic findings of bone block allografts in a 4 years follow-up: a case series

    Energy Technology Data Exchange (ETDEWEB)

    Deluiz, Daniel; Pires, Fabio Ramoa; Tinoco, Justine Monnerat; Tinoco, Eduardo Muniz Barretto [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil); Oliveira, Luciano Santos, E-mail: d.deluiz@implanto-puc.org [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), Rio de Janeiro, RJ (Brazil); Fletcher, Paul [Department of Periodontology, Columbia University College of Dental Medicine, New York, NY (United States)

    2016-11-15

    The aim of this paper is to report histologic and tomographic findings of fresh frozen bone block allografts bearing dental implants in functional occlusion in a long-term follow-up. Four patients with implants functionally loaded for 4 years on augmented ridges requiring additional mucogingival surgery or implant placement were included in this case series. Cone-beam tomography scans were compared volumetrically between the baseline (first implant placement) and current images. Biopsies of the grafts were retrieved and sent to histological analysis. Volumetric reduction of the grafts varied from 2.1 to 7.7%. Histological evaluation demonstrated well-incorporated grafts with different degrees of remodeling. While data presented in this report are from a small sample size and do not allow definitive conclusions, the biopsies of the grafted sites were very similar to the host's native bone. Remodeling of the cortical portion of the allografts seems to take longer than the cancellous portion. The presence of unincorporated graft remains did not impair the implant success or the health of the surrounding tissues. This is the first time histologic and tomographic long term data of bone allograft have been made available in dentistry. (author)

  15. Histologic and tomographic findings of bone block allografts in a 4 years follow-up: a case series

    International Nuclear Information System (INIS)

    Deluiz, Daniel; Pires, Fabio Ramoa; Tinoco, Justine Monnerat; Tinoco, Eduardo Muniz Barretto; Oliveira, Luciano Santos; Fletcher, Paul

    2016-01-01

    The aim of this paper is to report histologic and tomographic findings of fresh frozen bone block allografts bearing dental implants in functional occlusion in a long-term follow-up. Four patients with implants functionally loaded for 4 years on augmented ridges requiring additional mucogingival surgery or implant placement were included in this case series. Cone-beam tomography scans were compared volumetrically between the baseline (first implant placement) and current images. Biopsies of the grafts were retrieved and sent to histological analysis. Volumetric reduction of the grafts varied from 2.1 to 7.7%. Histological evaluation demonstrated well-incorporated grafts with different degrees of remodeling. While data presented in this report are from a small sample size and do not allow definitive conclusions, the biopsies of the grafted sites were very similar to the host's native bone. Remodeling of the cortical portion of the allografts seems to take longer than the cancellous portion. The presence of unincorporated graft remains did not impair the implant success or the health of the surrounding tissues. This is the first time histologic and tomographic long term data of bone allograft have been made available in dentistry. (author)

  16. Computerized Classification Testing with the Rasch Model

    Science.gov (United States)

    Eggen, Theo J. H. M.

    2011-01-01

    If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…

  17. Method for calibration of an axial tomographic scanner

    International Nuclear Information System (INIS)

    Sparks, R.A.

    1977-01-01

    The method of calibrating an axial tomographic scanner including frame means having an opening therein in which an object to be examined is to be placed, source and detector means mounted on the frame means for directing one or more beams of penetrating radiation through the object from the source to the detector means, and means to rotate the scanner including the source and detector means about the object whereby a plurality of sets of data corresponding to the transmission or absorption by the object of a plurality of beams of penetrating radiation are collected; the calibration method comprising mounting calibration means supporting an adjustable centering member onto the frame means, positioning the adjustable centering member at approximately the center of rotation of the scanner, placing position-sensitive indicator means adjacent the approximately centered member, rotating the scanner and the calibration means mounted thereon at least one time and, if necessary, adjusting the positioning of the centering member until the centering member is coincident with the center of rotation of the scanner as determined by minimum deflection of the position-sensitive indicator means, rotating and translating the source and detector means and determining for each angular orientation of the frame means supporting the source and detector means the central position of each translational scan relative to the centered member and/or if a plurality of detectors are utilized with the detector means for each planar slice of the object being examined, the central position of each translational scan for each detector relative to the centered member

  18. Positron emission tomographic imaging of cardiac sympathetic innervation and function

    International Nuclear Information System (INIS)

    Goldstein, D.S.; Chang, P.C.; Eisenhofer, G.; Miletich, R.; Finn, R.; Bacher, J.; Kirk, K.L.; Bacharach, S.; Kopin, I.J.

    1990-01-01

    Sites of uptake, storage, and metabolism of [ 18 F]fluorodopamine and excretion of [ 18 F]fluorodopamine and its metabolites were visualized using positron emission tomographic (PET) scanning after intravenous injection of the tracer into anesthetized dogs. Radioactivity was concentrated in the renal pelvis, heart, liver, spleen, salivary glands, and gall bladder. Uptake of 18F by the heart resulted in striking delineation of the left ventricular myocardium. Pretreatment with desipramine markedly decreased cardiac positron emission, consistent with dependence of the heart on neuronal uptake (uptake-1) for removal of circulating catecholamines. In reserpinized animals, cardiac positron emission was absent within 30 minutes after injection of [ 18 F]-6-fluorodopamine, demonstrating that the emission in untreated animals was from radioactive labeling of the sympathetic storage vesicles. Decreased positron emission from denervated salivary glands confirmed that the tracer was concentrated in sympathetic neurons. Radioactivity in the gall bladder and urinary system depicted the hepatic and renal excretion of the tracer and its metabolites. Administration of tyramine or nitroprusside increased and ganglionic blockade with trimethaphan decreased the rate of loss of myocardial radioactivity. The results show that PET scanning after administration of [ 18 F]fluorodopamine can be used to visualize sites of sympathetic innervation, follow the metabolism and renal and hepatic excretion of catecholamines, and examine cardiac sympathetic function

  19. Radiation protection in computerized tomography diagnostics; Strahlenschutz in der Computertomografie

    Energy Technology Data Exchange (ETDEWEB)

    Grust, Andreas [Radiologie am Hauptbahnhof, Duesseldorf (Germany)

    2012-11-01

    The essential advantage of computerized tomography (CT) compared to projecting radiographic techniques is the display of organs free of superposition using a 3D data set and additional enhanced contrast resolution. CT is a mostly objective and examination-independent technique that has developed towards an indispensable tool for tumor diagnostics and traumatology. With respect to the total amount of X-ray diagnostic examinations CT is a rather seldom used technique, nevertheless causing a disproportionately high amount of the collective effective dose of the German population. This disadvantage triggers the necessity to work on a radiation dose reduction. The author discusses the issues X-ray tube current reduction, layer thickness, pitch factor, scan length, dose modulation, adaptive collimation, and iterative reconstruction.

  20. Tomographic findings of lobar consolidation in primary pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Pereira, Bruno Alberto Falcao; Macedo, Solange Goncalves David de; Penna, Claudia Renata Rezende

    2009-01-01

    Objective: To describe tomographic findings of lobar consolidation as early manifestation of primary pulmonary tuberculosis. Materials and methods: The present study was developed at Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2002 and 2006, retrospectively evaluating tomographic findings in four children aged from 3 to 14 months with lobar consolidation as an early manifestation of primary pulmonary tuberculosis. Results: The most frequently found radiological pattern was lobar consolidation with calcifications, cavitation and intermingle necrotic areas, associated with bulging fissure. Signs of bronchogenic dissemination and lymph node enlargement were observed in all of the four children. Consolidation with a pseudotumor aspect and masslike effect was observed in one case. Conclusion: The cases included in the present study have demonstrated that primary pulmonary tuberculosis manifested as lobar consolidation presents typical tomographic images such as cavitation, hypodense areas and calcifications intermingled with consolidation. The association with lymph node enlargement with central necrosis and signs of bronchogenic dissemination reinforce the diagnosis of tuberculosis. (author)

  1. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  2. Computerized tomography findings of acute traumatic epidural hematoma

    International Nuclear Information System (INIS)

    Kobayashi, Shiro; Nakazawa, Shozo; Yokota, Hiroyuki; Yajima, Kouzo; Yano, Masami; Otsuka, Toshibumi

    1984-01-01

    During four year period from April, 1977 to March, 1981, 53 cases with acute traumatic epidural hematoma had been encountered out of 430 acute head injured patients examined by computerized tomography (CT) within 24 hours after incurring the trauma. Besides the initial CT, the authors performed contrast enhanced CT (41 cases) and serial CT scanning (31 cases). There were 49 cases of epidural hematoma existing in the supratentorial region, Two cases infratentorial region and 2 cases in the both regions. Two cases of vertex epidural hematoma had been encountered, one of them required vertical scan technique. In 22 (41%) of the 53 patients, the initial CT showed evidence of other cerebral lesions. The most frequent lesion was pneumocephalus (11 cases), 3 cases of them existed in the epidural hematoma. There were also intracerebral hematoma (6 cases), subdural hematoma (4 cases), cerebral contusion (2 cases), intraventricular hemorrhage (2 cases) and 2 cases of them demonstrated ''diffuse traumatic cerebral injury''. During contrast enhanced CT, 11 cases out of 41 cases indicated several enhancement pattern. There were total enhancement of epidural hematoma (2 cases), partial enhancement of hematoma (2 cases) and enhancement of internal margin of hematoma (2 cases). Serial CT scans was performed in 36 out of the 53 patients. Common findings on the serial CT scans were decreased density collection in the subdural space such as subdural effusions or chronic subdural hematomas (8 cases) and enlargement of small epidural hematomas (3 cases). After evacuation of epidural hematoma, there were some cases showing the so-called ''delayed traumatic intracerebral hematoma'' (4 cases), appearance of other epidural hematoma (1 case) and development of small cerebral infarction in the basal ganglia. There was one case indicating appearance of a new epidural hematoma contra lateral to the side of evacuation of subdural hematoma. (J.P.N.)

  3. Tomographic images of cerebral blood flow using a slant hole collimator

    International Nuclear Information System (INIS)

    Wraight, E.P.; Barber, R.W.; Crossland, P.; Maltby, P.

    1983-01-01

    The feasibility of using a rotating slant hole (RSH) collimator on simple tomographic equipment such as a standard gamma camera interfaced to a general purpose Nuclear Medicine computer is reported for producing images of cerebral blood flow following the administration of 123 I-iodoamphetamine to patients. Initial studies produced satisfactory images, thus opening the possibility of tomographic cerebral blood flow imaging to centres not possessing sophisticated tomographic equipment. Planar resolution is superior to that reported for a 25 0 RSH collimator. Axial resolution is not as good at small source distances but is comparable at distances beyond 10 cm. Sensitivity is comparable to other RSH collimators and is similar to Technicare's parallel hole general all purpose collimator. (UK)

  4. Present state and development of positron tomographs

    International Nuclear Information System (INIS)

    Allemand, R.; Gariod, R.; Laval, M.; Tournier, F.

    1979-01-01

    This document presents the main characteristics of positron tomographs and analyses the relative importance of the parameters to be taken into consideration in the design of a tomograph: on the one hand, the physical parameters linked to the measurement of the annihilation photons by time coincidence and, on the other, the geometrical and technological parameters of prime importance in minimizing the many spurious effects. The last part endeavours to show this sort of instrumentation has evolved. Using the results obtained in our laboratory by mathematical simulation, the expected advantages are presented on the picture quality of the time of flight measurement of annihilation photons. Where the physical aspects of this method are concerned, the advantage of using cesium fluoride as scintillator is demonstrated [fr

  5. Non-rigid registration of tomographic images with Fourier transforms

    International Nuclear Information System (INIS)

    Osorio, Ar; Isoardi, Ra; Mato, G

    2007-01-01

    Spatial image registration of deformable body parts such as thorax and abdomen has important medical applications, but at the same time, it represents an important computational challenge. In this work we propose an automatic algorithm to perform non-rigid registration of tomographic images using a non-rigid model based on Fourier transforms. As a measure of similarity, we use the correlation coefficient, finding that the optimal order of the transformation is n = 3 (36 parameters). We apply this method to a digital phantom and to 7 pairs of patient images corresponding to clinical CT scans. The preliminary results indicate a fairly good agreement according to medical experts, with an average registration error of 2 mm for the case of clinical images. For 2D images (dimensions 512x512), the average running time for the algorithm is 15 seconds using a standard personal computer. Summarizing, we find that intra-modality registration of the abdomen can be achieved with acceptable accuracy for slight deformations and can be extended to 3D with a reasonable execution time

  6. The bar coil for NMR tomograph

    International Nuclear Information System (INIS)

    Bogorodzki, P.; Piatkowski, A.; Wasielewski, J.

    1995-01-01

    The bar coil (bi-planar) for the NMR tomograph, designed for medical diagnostics, has been described. The tests of coil shown that it generates good homogenous magnetic field in a big volume what results in improving of the signal-to-noise ratio

  7. Computerized tomography in orthopaedics and traumatology

    International Nuclear Information System (INIS)

    Boettger, E.; Heckl, R.; Rehabilitations-Krankenhaus Langensteinbach, Karlsbad

    1981-01-01

    Computerized tomography in traumatology is the selected method for the indications mentioned, so that angiographic investigations are only necessary in exceptional cases. Computerized tomography is also better than other methods when diagnozing soft part tumours, however, angiography is still indicated preoperatively for individual cases. CT is only good as additional help to conventional diagnostics with bone tumours. The differential diagnosis cysts-tumour is possible using contrast medium injections. The frequently large soft part share of tumours is recognizable with osteolytic tumours so that a better irradiation and operation planning can be effected. Diseases in the spinal canal can only be assessed with reservation using modern equipment. Lumbar dislocations of the disk can mostly not be sufficiently determined. Perivertebral abscesses can be certainly detected using computerized tomography. This is particularly so for abscesses prior to calcification. (orig.) [de

  8. Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, I., E-mail: isabelle.abraham@cea.fr [CEA Ile de France (France); Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr [Université d’Orléans, UFR Sciences, MAPMO, UMR 7349 (France); Carlier, G., E-mail: carlier@ceremade.dauphine.fr [CEREMADE, UMR CNRS 7534, Université Paris IX Dauphine, Pl. de Lattre de Tassigny (France)

    2017-02-15

    In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.

  9. Reconstruction of tomographic image from x-ray projections of a few views

    International Nuclear Information System (INIS)

    Kobayashi, Fujio; Yamaguchi, Shoichiro

    1982-01-01

    Computer tomographs have progressed rapidly, and in the latest high performance types, the photographing time has been shortened to less than 5 sec, but the clear images of hearts have not yet been obtained. The X-ray tomographs used so far irradiate X-ray from many directions and measure the projected data, but by limiting projection direction to a small number, it was planned to shorter the X-ray photographing time and to reduce X-ray exposure as the objective of this study. In this paper, a method is proposed, by which tomographic images are reconstructed from projected data in a small number of direction by generalized inverse matrix penalty method. This method is the calculation method newly devised by the authors for this purpose. It is a kind of the nonlinear planning method added with the restrictive condition using a generalized inverse matrix, and it is characterized by the simple calculation procedure and rapid convergence. Moreover, the effect on reconstructed images when errors are included in projected data was examined. Also, the simple computer simulation to reconstruct tomographic images using the projected data in four directions was performed, and the usefulness of this method was confirmed. It contributes to the development of superhigh speed tomographs in future. (Kako, I.)

  10. Computerized Italian criticality guide, description and validation

    International Nuclear Information System (INIS)

    Carotenuto, M.; Landeyro, P.A.

    1988-10-01

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  11. Computerized Italian criticality guide, description and validation

    Energy Technology Data Exchange (ETDEWEB)

    Carotenuto, M; Landeyro, P A [ENEA - Dipartimento Ciclo del Combustibile, Centro Ricerche Energia, Casaccia (Italy)

    1988-10-15

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  12. Tomographic ventricular reconstruction using multiple view first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lacy, J.L.; Ball, M.E.; Verani, M.S.; Wiles, H.; Roberts, R.

    1985-01-01

    In first-pass radionuclide angiography (FPRA) images of both left and right ventricles are uncontaminated by adjacent structures. Thus, the problem of tomographic reconstruction is vastly simplified compared to equilibrium blood pool imaging in which all structures are imaged simultaneously. Tomographic reconstruction from a limited number of views may thus be possible. A simple filtered interpolative back-projection reconstruction technique was employed. In this technique interpolation was used between sectional distributions at successive angles. Interpolations yielding 9 and 13 back projection angles of 22.5 0 and 15 0 were evaluated. Ventricular borders were obtained in each back-projected tomographic slice by location of the intensity level which provided correct total ventricular volume. Cast cross sections were quantitatively well represented by these borders. This ventricular border definition algorithm forms the basis for applications of the technique in animals and humans

  13. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  14. Bone scanning a useful addition in the diagnosis of ankle joint trauma

    International Nuclear Information System (INIS)

    Schmidt, C.

    1983-01-01

    A retrospective study of the indication in 169 scintigraphic examinations of the ankle joint was made. Usually joints respond to trauma with a generalized increase of the concentration of the radiopharmaceutical. By using a highly performed technique the focal hot spot caused by the fracture can be seen in the bone scan. The focal accumulation of the radioactive material must not correspond to a bone fracture in any case. The ligamentous avulsion of a bone chip and/or the periosteum can yield the same image but it cannot be diagnosed by radiographic techniques. Initially the routine radiograph and even the tomograph often are interpreted as normal or equivocal. In these cases of ankle trauma bone scanning completes the clinical evaluation. Although bone scanning is very important in the diagnosis of any traumatic lesion of the ankle joints it cannot replace the conventional X-ray technique. (orig.) [de

  15. Tomographic image reconstruction using training images

    DEFF Research Database (Denmark)

    Soltani, Sara; Andersen, Martin Skovgaard; Hansen, Per Christian

    2017-01-01

    We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a non-negative dictionary based on prototype elements from the training images; this problem is formulated within...

  16. Image interface in Java for tomographic reconstruction in nuclear medicine

    International Nuclear Information System (INIS)

    Andrade, M.A.; Silva, A.M. Marques da

    2004-01-01

    The aim of this study is to implement a software for tomographic reconstruction of SPECT data from Nuclear Medicine with a flexible interface design, cross-platform, written in Java. Validation tests were performed based on SPECT simulated data. The results showed that the implemented algorithms and filters agree with the theoretical context. We intend to extend the system by implementing additional tomographic reconstruction techniques and Java threads, in order to provide simultaneously image processing. (author)

  17. Pressure spectra from single-snapshot tomographic PIV

    Science.gov (United States)

    Schneiders, Jan F. G.; Avallone, Francesco; Pröbsting, Stefan; Ragni, Daniele; Scarano, Fulvio

    2018-03-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor's hypothesis (TH) of frozen turbulence and vortex-in-cell (VIC) simulation. Finite time marching of the measured instantaneous velocity fields is performed using TH and VIC. Pressure is calculated from the resulting velocity time series. Because of the theoretical limitations, the finite time marching can be performed until the measured flow structures are convected out of the measurement volume. This provides a lower limit of resolvable frequency range. An upper limit is given by the spatial resolution of the measurements. Finite time-marching approaches are applied to low-repetition-rate tomographic PIV data of the flow past a straight trailing edge at 10 m/s. Reference results of the power spectral density and coherence are obtained from surface pressure transducers. In addition, the results are compared to state-of-the-art experimental data obtained from time-resolved tomographic PIV performed at 10 kHz. The time-resolved approach suffers from low spatial resolution and limited maximum acquisition frequency because of hardware limitations. Additionally, these approaches strongly depend upon the time kernel length chosen for pressure evaluation. On the other hand, the finite time-marching approaches make use of low-repetition-rate tomographic PIV measurements that offer higher spatial resolution. Consequently, increased accuracy of the power spectral density and coherence of pressure fluctuations are obtained in the high-frequency range, in comparison to the time-resolved measurements. The approaches based on TH and VIC are found to perform similarly in the high-frequency range. At lower frequencies, TH is found to underestimate coherence and intensity of the pressure fluctuations in comparison to time-resolved PIV

  18. Development of the two Korean adult tomographic computational phantoms for organ dosimetry

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lee, Choonik; Park, Sang-Hyun; Lee, Jai-Ki

    2006-01-01

    Following the previously developed Korean tomographic phantom, KORMAN, two additional whole-body tomographic phantoms of Korean adult males were developed from magnetic resonance (MR) and computed tomography (CT) images, respectively. Two healthy male volunteers, whose body dimensions were fairly representative of the average Korean adult male, were recruited and scanned for phantom development. Contiguous whole body MR images were obtained from one subject exclusive of the arms, while whole-body CT images were acquired from the second individual. A total of 29 organs and tissues and 19 skeletal sites were segmented via image manipulation techniques such as gray-level thresholding, region growing, and manual drawing, in which each of segmented image slice was subsequently reviewed by an experienced radiologist for anatomical accuracy. The resulting phantoms, the MR-based KTMAN-1 (Korean Typical MAN-1) and the CT-based KTMAN-2 (Korean Typical MAN-2), consist of 300x150x344 voxels with a voxel resolution of 2x2x5 mm 3 for both phantoms. Masses of segmented organs and tissues were calculated as the product of a nominal reference density, the prevoxel volume, and the cumulative number of voxels defining each organs or tissue. These organs masses were then compared with those of both the Asian and the ICRP reference adult male. Organ masses within both KTMAN-1 and KTMAN-2 showed differences within 40% of Asian and ICRP reference values, with the exception of the skin, gall bladder, and pancreas which displayed larger differences. The resulting three-dimensional binary file was ported to the Monte Carlo code MCNPX2.4 to calculate organ doses following external irradiation for illustrative purposes. Colon, lung, liver, and stomach absorbed doses, as well as the effective dose, for idealized photon irradiation geometries (anterior-posterior and right lateral) were determined, and then compared with data from two other tomographic phantoms (Asian and Caucasian), and

  19. Positioning of Nuclear Fuel Assemblies by Means of Image Analysis on Tomographic Data

    International Nuclear Information System (INIS)

    Troeng, Mats

    2005-06-01

    A tomographic measurement technique for nuclear fuel assemblies has been developed at the Department of Radiation Sciences at Uppsala University. The technique requires highly accurate information about the position of the measured nuclear fuel assembly relative to the measurement equipment. In experimental campaigns performed earlier, separate positioning measurements have therefore been performed in connection to the tomographic measurements. In this work, another positioning approach has been investigated, which requires only the collection of tomographic data. Here, a simplified tomographic reconstruction is performed, whereby an image is obtained. By performing image analysis on this image, the lateral and angular position of the fuel assembly can be determined. The position information can then be used to perform a more accurate tomographic reconstruction involving detailed physical modeling. Two image analysis techniques have been developed in this work. The stability of the two techniques with respect to some central parameters has been studied. The agreement between these image analysis techniques and the previously used positioning technique was found to meet the desired requirements. Furthermore, it has been shown that the image analysis techniques offer more detailed information than the previous technique. In addition, its off-line analysis properties reduce the need for valuable measurement time. When utilizing the positions obtained from the image analysis techniques in tomographic reconstructions of the rod-by-rod power distribution, the repeatability of the reconstructed values was improved. Furthermore, the reconstructions resulted in better agreement to theoretical data

  20. Decomposition of time-resolved tomographic PIV

    NARCIS (Netherlands)

    Schmid, P.J.; Violato, D.; Scarano, F.

    2012-01-01

    An experimental study has been conducted on a transitional water jet at a Reynolds number of Re = 5,000. Flow fields have been obtained by means of time-resolved tomographic particle image velocimetry capturing all relevant spatial and temporal scales. The measured threedimensional flow fields have

  1. Connections model for tomographic images reconstruction

    International Nuclear Information System (INIS)

    Rodrigues, R.G.S.; Pela, C.A.; Roque, S.F. A.C.

    1998-01-01

    This paper shows an artificial neural network with an adequately topology for tomographic image reconstruction. The associated error function is derived and the learning algorithm is make. The simulated results are presented and demonstrate the existence of a generalized solution for nets with linear activation function. (Author)

  2. Tomographic methods in nuclear medicine

    International Nuclear Information System (INIS)

    Ahluwalia, B.D.

    1989-01-01

    This book is a review of the various approaches to tomographic imaging that have been pursued in nuclear medicine. The evolution of single photon emission computed tomography (SPECT) is discussed in detail, and the major classes of instrumentation are represented. A section on positron emission tomography is also included, but is rather brief and may serve only as a general introduction

  3. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    Science.gov (United States)

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  4. Computed tomography of orbital myositis

    International Nuclear Information System (INIS)

    Dresner, S.C.; Rothfus, W.E.; Slamovits, T.L.; Kennerdell, J.S.; Curtin, H.D.

    1984-01-01

    The computerized tomographic (CT) scans of 11 consecutive patients with orbital myositis were reviewed to better characterize the CT appearance of this condition. The findings in this series differed from those of previous reports in several ways. Multiple muscle involvement predominated. Bilateral involvement was more frequent than previously reported. Enlargement of the tendon as well as the muscle was a frequent finding, but a normal tendinous insertion did not preclude the diagnosis of orbital myositis. Although the CT appearance of orbital myositis is often helpful, the findings are not pathognomonic; correlation with history, clinical findings, and therapeutic response must be considered in making the diagnosis

  5. Research on accounting transition from computerization to informationization

    Directory of Open Access Journals (Sweden)

    Shu Chen

    2017-11-01

    Full Text Available The application for computer technology, digitalization technology and network technology in the accounting field has promoted the development of accounting informationization. Accounting informationization is a product integrated with traditional accounting theory and modern information technology, which is an inevitable trend of continuous development of modern accounting. This paper discusses the basic concepts and characteristics of accounting computerization and informationization based on the normative research method and literature data method, analyzes the feasibility of accounting transition from computerization to informationization, and finally puts forward the specific approaches and ultimate goals of accounting transition from computerization to informationization.

  6. Cranial computerized tomography in children suffering from acute leukemia

    International Nuclear Information System (INIS)

    Metz, O.

    1981-01-01

    Cranial computerized (axial) tomography permits a more complete neurologic supervision of children with acute leukemia and a better knowledge of the frequency and varieties of cerebral complications in leukemia. Endocranial complications in acute leukemia are essentially infiltrative, hemorrhagic, infectious or iatrogenic. Cranial computerized tomography can demonstrate cerebral changes in meningeal leukemia, hemorrhages, calcifications, brain atrophy or leukencephalopathy. The preliminary results of cranial computerized tomography in childhood leukemia suggest that the iatrogenic main lesion of the brain due to combined radiation-chemotherapy is atrophy whereas that of the intrathecal cytostatic therapy is demyelination. Accurate diagnostics and control of possible cerebral complications in therapy of leukemia is essentially for appropriate therapeutic management. For that cranial computerized tomography is the best method to a effective supervision of the brain. (author)

  7. Clinical study on primary epilepsy by computerized analysis of CT

    International Nuclear Information System (INIS)

    Tominaga, Hidefumi; Ueyama, Kenichi; Mizutani, Hiroshi; Imamura, Keisuke; Yoshidome, Kazushi; Matsumoto, Kei

    1985-01-01

    CT scans were examined by conventional linear measurement method and computerized analysis in 17 patients with primary epilepsy (Group A). Results were compared with those in healthy volunteers (Group B). Relationship between CT and EEG findings was also examined. The maximum width of the third cerebral ventricle (TCV) was narrowed in Group A than in Group B, with statistically significant difference. Low density rates (LDR) in Group A tended to be lower than those in Group B. There was significant difference in narrowed maximum width of TCV between Group A presenting with sudden dysrhythmia and Group B. For this type of Group A, LDR was significantly lower than that for Group B. These results suggest some changes in the brain in young epilepsy patients, especially those presenting with sudden dysrhythemia. (Namekawa, K.)

  8. Regional cerebral blood flow during rest and skilled hand movements by xenon-133 inhalation and emission computerized tomography

    International Nuclear Information System (INIS)

    Lauritzen, M.; Henriksen, L.; Lassen, N.A.

    1981-01-01

    Regional cerebral blood flow (CBF) was studied in 16 normal adult volunteers during rest and in 10 the study was repeated during skilled hand movements. A fast-rotating (''dynamic''), single-photon emission computerized tomograph (ECT) with four detector heads was used. Xenon-133 was inhaled over a 1-min period at a concentration of 10 mCi/L. The arrival and washout of the radioisotope was recorded during four 1-min periods. Two slices, 2 cm thick, 7 and 12 cm above the orbitomeatal line were obtained in every study. CBF averaged 60 ml/100 g/min (SD +/- 11) in the lower slice and 51 ml/100 g/min (SD +/- 13) in the upper slice. A symmetric pattern comparing right to left sides was found in both slices. Finger tapping and writing with the right hand increased CBF in specific areas of the upper slice: in the contralateral hand area by 35 +/- 15% (p less than 0.025), and in the supplementary motor area on both sides by 34 +/- 15%

  9. Quantitative computerized tomography for staging and follow up of patients with prostatic cancer

    International Nuclear Information System (INIS)

    Golimbu, C.; Golimbu, M.; Firooznia, H.; Rafii, M.; Morales, P.

    1987-01-01

    Prostate carcinoma has propensity to metastasize to skeleton, most frequently affecting the lumbar spine. The isotope bone scan and serum prostatic acid phosphatase (PAP) have been considered most reliable in documenting cancer spread. However, the former has been shown to have low specificity, and the latter was found to be increased in patients with localized disease or normal in patients with proven metastases. In a previous study of a group of patients at risk of having metastatic bone involvement, albeit not revealed by standard methods, the authors demonstrated the ability of quantitative computerized tomography (QCT) to depict early stages of bone metastases (Golimbu et. al., 1986). They also demonstrated its usefulness in assessing the response to treatment. The authors extended their study to further evaluate the accuracy of QCT in comparison with Tc99m bone scan and serum PAP for early detection of bone metastases and for quantitation of metastatic bone lesions response to therapy

  10. Design of a muonic tomographic detector to scan travelling containers

    International Nuclear Information System (INIS)

    Pugliatti, C; Bandieramonte, M; Blancato, A A; Bonanno, D L; Indelicato, V; Rocca, P La; Presti, D Lo; Antonuccio, V; Becciani, U; Belluso, M; Billotta, S; Bonanno, G; Costa, A; Garozzo, S; Massimino, P; Belluomo, F; Fallica, G; Leonora, E; Longhitano, F; Longo, S

    2014-01-01

    The Muon Portal Project aims at the construction of a large volume detector to inspect the content of travelling containers for the identification of high-Z hidden materials (U, Pu or other fissile samples), exploiting the secondary cosmic-ray muon radiation. An image of these materials is achieved reconstructing the deviations of the muons from their original trajectories inside the detector volume, by means of two particle trackers, placed one below and one above the container. The scan is performed without adding any external radiation, in a few minutes and with a high spatial and angular resolution. The detector consists of 4800 scintillating strips with two wavelength shifting (WLS) fibers inside each strip, coupled to Silicon photomultipliers (SiPMs). A smart strategy for the read out system allows a considerable reduction of the number of the read-out channels. Actually, an intense measurement campaign is in progress to carefully characterize any single component of the detector. A prototype of one of the 48 detection modules (1 × 3 m 2 ) is actually under construction. This paper presents the detector architecture and the preliminary results

  11. Cerebral imaging using 68Ga DTPA and the U.C.S.F. multiwire proportional chamber positron camera

    International Nuclear Information System (INIS)

    Hattner, R.S.; Lim, C.B.; Swann, S.J.; Kaufman, L.; Perez-Mendez, V.; Chu, D.; Huberty, J.P.; Price, D.C.; Wilson, C.B.

    1975-12-01

    A multiwire proportional chamber positron camera consisting of four 48 x 48 cm 2 detectors linked to a small digital computer has been designed, constructed, and characterized. Initial clinical application to brain imaging using 68 Ga DTPA in 10 patients with brain tumors is described. Tomographic image reconstruction is accomplished by an algorithm determining the intersection of the annihilation photon paths in planes of interest. Final image processing utilizes uniformity correction, simple thresholding, and smoothing. The positron brain images were compared to conventional scintillation brain scans and x-ray computerized axial tomograms (CAT) in each case. The positron studies have shown significant mitigation of confusing superficial activity resulting from craniotomy in comparison to conventional brain scans. Central necrosis of lesions observed in the positron images, but not in the conventional scans, has been confirmed in CAT. Modifications of the camera are being implemented to improve image quality, and these changes combined with the tomography inherent in the positron scans are anticipated to result in images superior in information content to conventional brain scans

  12. Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

    International Nuclear Information System (INIS)

    Frayer, Daniel K.; Johnson, Douglas; Ekdahl, Carl

    2010-01-01

    An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

  13. Computerized adaptive testing--ready for ambulatory monitoring?

    DEFF Research Database (Denmark)

    Rose, Matthias; Bjørner, Jakob; Fischer, Felix

    2012-01-01

    Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted.......Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted....

  14. Tomographic imaging of subducted lithosphere below northwest Pacific island arcs

    Science.gov (United States)

    Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.

    1991-01-01

    The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.

  15. Effect of The Measuring Parameters on The Reconstructed Images by Computerized Tomography

    International Nuclear Information System (INIS)

    Ali, A.M.; Ali, A.M.; Megahid, R.M.

    2011-01-01

    In this paper, the potential of computerized tomography by neutrons and gamma rays as a main precise technique for nondestructive assay of materials and components of prime importance in nuclear and general industries are given and discussed. Both Fast Fourier Transform (FFT) and convolution techniques are introduced. Shepp and Logan human head phantom is used for theoretical testing and studying the effect of translation value for both techniques. Moreover, the effect of the projection number discussed. Comparison between the two reconstruction techniques wasper formed for the examined object. In addition, some of the experimentally scanned images using slit beam of gamma rays emitt ed from the ETRR- 1 reactor are presented and discussed.

  16. Visual scanning training for neglect after stroke with and without a computerized lane tracking dual task

    NARCIS (Netherlands)

    van Kessel, M. E.; Geurts, A. C. H.; Brouwer, W. H.; Fasotti, L.

    2013-01-01

    Neglect patients typically fail to explore the contralesional half-space. During visual scanning training, these patients learn to consciously pay attention to contralesional target stimuli. It has been suggested that combining scanning training with methods addressing non-spatial attention might

  17. Automated segmentation of tumors on bone scans using anatomy-specific thresholding

    Science.gov (United States)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Lu, Peiyun; Ramakrishna, Bharath; Gjertson, David; Poon, Cheryce; Auerbach, Martin; Goldin, Jonathan; Brown, Matthew S.

    2012-03-01

    Quantification of overall tumor area on bone scans may be a potential biomarker for treatment response assessment and has, to date, not been investigated. Segmentation of bone metastases on bone scans is a fundamental step for this response marker. In this paper, we propose a fully automated computerized method for the segmentation of bone metastases on bone scans, taking into account characteristics of different anatomic regions. A scan is first segmented into anatomic regions via an atlas-based segmentation procedure, which involves non-rigidly registering a labeled atlas scan to the patient scan. Next, an intensity normalization method is applied to account for varying levels of radiotracer dosing levels and scan timing. Lastly, lesions are segmented via anatomic regionspecific intensity thresholding. Thresholds are chosen by receiver operating characteristic (ROC) curve analysis against manual contouring by board certified nuclear medicine physicians. A leave-one-out cross validation of our method on a set of 39 bone scans with metastases marked by 2 board-certified nuclear medicine physicians yielded a median sensitivity of 95.5%, and specificity of 93.9%. Our method was compared with a global intensity thresholding method. The results show a comparable sensitivity and significantly improved overall specificity, with a p-value of 0.0069.

  18. Computerized data base of the fundamental constants of nature

    International Nuclear Information System (INIS)

    Henry, E.A.; Hampel, V.E.

    1975-01-01

    Fifty-seven fundamental constants of nature were computerized from the up-to-date evaluations of E. R. Cohen and B. N. Taylor. The constants are annotated with regard to symbol, value, uncertainty, and scaling factor. This computerization is part of the scientific data base project of the Information Research Group at Lawrence Livermore Laboratory. The MASTER CONTROL data base management system is used. The computerized fundamental constants can be requested from the ERDA Computer Program Exchange and Information Center of the Argonne National Laboratory or from the National Technical Information Service of the U. S. Department of Commerce. This is the first of a series of releases on preparation of computerized scientific and technological data banks. The next release is a data bank of conversion factors for different units of measurements. 3 figures

  19. Registration of synthetic tomographic projection data sets using cross-correlation

    International Nuclear Information System (INIS)

    Fitchard, E.E.; Aldridge, J.S.; Reckwerdt, P.J.; Mackie, T.R.

    1998-01-01

    Tomographic registration, a method that makes possible accurate patient registration directly from projection data, consists of three processing steps: (i) manual coarse positioning, (ii) tomographic projection set acquisition, and (iii) computer mediated refined positioning. In the coarse positioning stage, the degree of patient alignment is comparable with that achieved with the standard radiotherapy set-up. However, the accuracy requirements are somewhat more relaxed in that meticulous alignment of the patient using external laser indicators is not necessary. Instead, tomographic projection sets are compared with planning CTs in order to achieve improved patient set-up. The projection sets are cross-correlated to obtain the best-fit translation and rotation offsets. The algorithm has been tested on synthetic data with the incorporation of varying amounts of Gaussian pseudo-random noise. These tests demonstrate the algorithm's stability and also confirm that alignment can be achieved with an accuracy of less than one projection pixel. (author)

  20. Remote diagnosis via a telecommunication satellite--ultrasonic tomographic image transmission experiments.

    Science.gov (United States)

    Nakajima, I; Inokuchi, S; Tajima, T; Takahashi, T

    1985-04-01

    An experiment to transmit ultrasonic tomographic section images required for remote medical diagnosis and care was conducted using the mobile telecommunication satellite OSCAR-10. The images received showed the intestinal condition of a patient incapable of verbal communication, however the image screen had a fairly coarse particle structure. On the basis of these experiments, were considered as the transmission of ultrasonic tomographic images extremely effective in remote diagnosis.

  1. Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images

    International Nuclear Information System (INIS)

    Jeong, Ho Gul; Kim, Kee Deog; Hu, Kyung Seok; Lee, Jae Bum; Park, Hyok; Han, Seung Ho; Choi, Seong Ho; Kim, Chong Kwan; Park, Chang Seo

    2006-01-01

    To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed: 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analysed by Mann-Whitney test. There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement

  2. Static and dynamic 3 dimensional studies of water in soil using computed tomographic scanning

    International Nuclear Information System (INIS)

    Crestana, S.; Mascarenhas, S.; Pozzi-Mucelli, R.S.

    1984-03-01

    Previous work of Petrovic, Siebert and Rieke demonstrated the possibility of using X-ray transmission computed tomography (CT) scanning for soil bulk density analysis in soil. We show in the present work that CT can also be used for the measurement of water content in soil. In our case we also show that CT can be applied to measure and follow dynamically the motion of water in soil in 3-dimensions. Further, more inhomogeneities of water content and motion in soil can be observed with this technique. Using a third generation CT scanner several different techniques can be applied such as differential, real time and spatial distribution scanning modes. A linear dependence was demonstrated for the Hounsfield Units (HU) used in CT and water content. The use of CT for water content and motion in soil in 3-dimensions opens new possibilities in this area of investigations. (author)

  3. Computerized videodefecography versus defecography: do we need radiographs?

    Directory of Open Access Journals (Sweden)

    Carlos Walter Sobrado

    Full Text Available CONTEXT AND OBJECTIVE: Defecography has been recognized as a valuable method for evaluating patients with evacuation disorders. It consists of the use of static radiography and fluoroscopy to record different situations within anorectal dynamics. Conventionally, rectal parameters are measured using radiograms. It is rare for fluoroscopy alone to be used. Computer software has been developed with the specific aim of calculating these measurements from digitized videotaped images obtained during fluoroscopy, without the need for radiographic film, thereby developing a computerized videodefecography method. The objective was thus to compare measurements obtained via computerized videodefecography with conventional measurements and to discuss the advantages of the new method. DESIGN AND SETTING: Prospective study at the radiology service of Hospital das Clínicas, Universidade de São Paulo. METHOD: Ten consecutive normal subjects underwent videodefecography. The anorectal angle, anorectal junction, puborectalis muscle length, anal canal length and degree of anal relaxation were obtained via the conventional method (using radiography film and via computerized videodefecography using the ANGDIST software. Measurement and analysis of these parameters was performed by two independent physicians. RESULTS: Statistical analysis confirmed that the measurements obtained through direct radiography film assessment and using digital image analysis (computerized videodefecography were equivalent. CONCLUSIONS: Computerized videodefecography is equivalent to the traditional defecography examination. It has the advantage of offering reduced radiation exposure through saving on the use of radiography.

  4. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  5. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  6. 3D velocity measurements in a premixed flame by tomographic PIV

    International Nuclear Information System (INIS)

    Tokarev, M P; Sharaborin, D K; Lobasov, A S; Chikishev, L M; Dulin, V M; Markovich, D M

    2015-01-01

    Tomographic particle image velocimetry (PIV) has become a standard tool for 3D velocity measurements in non-reacting flows. However, the majority of the measurements in flows with combustion are limited to small resolved depth compared to the size of the field of view (typically 1 : 10). The limitations are associated with inhomogeneity of the volume illumination and the non-uniform flow seeding, the optical distortions and errors in the 3D calibration, and the unwanted flame luminosity. In the present work, the above constraints were overcome for the tomographic PIV experiment in a laminar axisymmetric premixed flame. The measurements were conducted for a 1 : 1 depth-to-size ratio using a system of eight CCD cameras and a 200 mJ pulsed laser. The results show that camera calibration based on the triangulation of the tracer particles in the non-reacting conditions provided reliable accuracy for the 3D image reconstruction in the flame. The modification of the tomographic reconstruction allowed a posteriori removal of unwanted bright objects, which were located outside of the region of interest but affected the reconstruction quality. This study reports on a novel experience for the instantaneous 3D velocimetry in laboratory-scale flames by using tomographic PIV. (paper)

  7. Computerized tomography in evaluation of the pulmonary hilum

    International Nuclear Information System (INIS)

    Secaf, M.; Ferreira, J.L.N.; Secaf, E.

    1987-01-01

    The use of computerized tomography as a method for evaluating the pulmonary hilum and its application in the diagnosis of endobronchial lesions, hilar masss, contiguous involvement of the mediastinum by hilar mass, and vascular hilar lesions are discussed. A comparative evaluation between conventional tomograms and computerized tomography is presented. (M.A.C.) [pt

  8. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  9. Regression of nodules on cranial computerized tomography (CCT) scans in 4 focal epileptic patients

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Yoon, Sei Chul; Park, Seog Hee; Huh, Choon Woong

    1983-01-01

    Epilepsy can be defined as a paroxysmal, excessive, neuronal discharge within the brain originating from either cortical or sugcortical regions. The incidence of epilepsy is increasing possibly due to the survival of persons who should have died of brain injuries or other cerebral abnormalities acquired in early life. The use of antibiotics and improvement in the medical care have saved many children who might have died of meningitis, brain abscess, encephalitis, severe head injuries, etc. CCT scan is new radiologic procedure for defining cranial and intracranial structures and also an useful procedure for evaluation and follow-up (FU) of patient with focal seizure disorder. Recently we experienced nodules which were isodense or hypodense on initial non contrasted CT (NECT) and scans became hyperdense of the enhancement in 4 cases of focal epileptic seizure. Nearly complete disappearance or regression of the epileptic foci occurred on the FU CT scans in 2 cases. Operation was performed in 2 cases. The tissue specimen obtained from the CT nodule revealed cerebral edema in one case and localized gliosis and congestion in the other. All the patients showed marked clinical improvement when the CT nodule improved. Review of literature failed to disclose any previous report on such observation

  10. Survey of methods for improving operator acceptance of computerized aids

    International Nuclear Information System (INIS)

    Frey, P.R.; Kisner, R.A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room

  11. Survey of methods for improving operator acceptance of computerized aids

    Energy Technology Data Exchange (ETDEWEB)

    Frey, P. R.; Kisner, R. A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room.

  12. Quantitative evaluation of catheter radiopacity by fiber optic scanning densitometry

    International Nuclear Information System (INIS)

    Solomon, D.D.; Byron, M.P.; Lipton, M.J.

    1989-01-01

    A rapid accurate method has been developed utilizing fiber optic scanning densitometry to quantify the radiopacity of vascular catheters. The technique provides for computerized calculation of relative catheter radiopacity and an appropriate control standard. A densitometer with a 180 degree collection angle for diffuse transmission density measurements was selected based on the diffusing nature of X-ray film (Q-factor 1.80). A benchmark catheter and 2 mil thick brass shim stock were selected as control standards for evaluation of mono-and multilumen tubing using standard X-ray conditions and an aluminum block attenuator. The authors present results from reproducibility studies which show scan-to-scan repeatability is within ±1%, and day-to-day variability is less than 5%. Application studies demonstrate a linear relationship between percent barium sulfate loading and the radiopaqueness of 16 gauge monolumen tubing. Results were also obtained from a clinical chest X-ray film showing good in-vivo/in-vitro correlation

  13. Computerized accounting methods. Final report

    International Nuclear Information System (INIS)

    1994-01-01

    This report summarizes the results of the research performed under the Task Order on computerized accounting methods in a period from 03 August to 31 December 1994. Computerized nuclear material accounting methods are analyzed and evaluated. Selected methods are implemented in a hardware-software complex developed as a prototype of the local network-based CONMIT system. This complex has been put into trial operation for test and evaluation of the selected methods at two selected ''Kurchatov Institute'' Russian Research Center (''KI'' RRC) nuclear facilities. Trial operation is carried out since the beginning of Initial Physical Inventory Taking in these facilities that was performed in November 1994. Operation of CONMIT prototype system was demonstrated in the middle of December 1994. Results of evaluation of CONMIT prototype system features and functioning under real operating conditions are considered. Conclusions are formulated on the ways of further development of computerized nuclear material accounting methods. The most important conclusion is a need to strengthen computer and information security features supported by the operating environment. Security provisions as well as other LANL Client/Server System approaches being developed by Los Alamos National Laboratory are recommended for selection of software and hardware components to be integrated into production version of CONMIT system for KI RRC

  14. Pressure spectra from single-snapshot tomographic PIV

    NARCIS (Netherlands)

    Schneiders, J.F.G.; Avallone, F.; Pröbsting, S.; Ragni, D.; Scarano, F.

    2018-01-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor’s hypothesis (TH) of frozen turbulence and

  15. Tomographic Particle Image Velocimetry Using Colored Shadow Imaging

    KAUST Repository

    Alarfaj, Meshal K.

    2016-02-01

    Tomographic Particle Image Velocimetry Using Colored Shadow Imaging by Meshal K Alarfaj, Master of Science King Abdullah University of Science & Technology, 2015 Tomographic Particle image velocimetry (PIV) is a recent PIV method capable of reconstructing the full 3D velocity field of complex flows, within a 3-D volume. For nearly the last decade, it has become the most powerful tool for study of turbulent velocity fields and promises great advancements in the study of fluid mechanics. Among the early published studies, a good number of researches have suggested enhancements and optimizations of different aspects of this technique to improve the effectiveness. One major aspect, which is the core of the present work, is related to reducing the cost of the Tomographic PIV setup. In this thesis, we attempt to reduce this cost by using an experimental setup exploiting 4 commercial digital still cameras in combination with low-cost Light emitting diodes (LEDs). We use two different colors to distinguish the two light pulses. By using colored shadows with red and green LEDs, we can identify the particle locations within the measurement volume, at the two different times, thereby allowing calculation of the velocities. The present work tests this technique on the flows patterns of a jet ejected from a tube in a water tank. Results from the images processing are presented and challenges discussed.

  16. Computed tomographic findings of liver injury in adults

    International Nuclear Information System (INIS)

    Ha, Deok Gi; Lee, Hyeon Kyeong; Lee, Won Jae; Oh, Yeon Hee; Lee, Sung Hee; Yun, Jee Yeong; Lee, Tae Woo; Lee, Sung Woo; Park, Soo Soung

    1994-01-01

    We studied to compare computed tomographic(CT) findings of liver injury with management method in adults and, moreover, to present the CT basis for the management. We retrospectively reviewed CT scans of 43 adults diagnosed as liver injury during a 66 month period. Thirty-eight patients were hemodynamically stable. Thirty-two of them were managed conservatively, whereas six managed operatively. Five unstable patients underwent emergency operation. We classified CT findings according to the severity of liver injuries(ie, hematoma, laceration, and periportal tracking) and hemoperitoneum, ranging from grade 1 to 5 and from 0 to 3 +. respectively. Thus, we compared the CT classifications with their management(ie, operation rate), especially hemodynamically stable patients. Operation rates of all patients and hemodynamically stable patients were 26% and 16%, respectively. Operation rate at each grade of liver injury was low, especially in hemodynamically stable, despite relatively high operation rate in grade 4. Operation rate of 3+ homoperitoneum was 100%, including hemodynamically stable patients, in contrast to otherwise low operation rate of others. Most liver injury in adults, including grade 4, were managed conservatively, especially hemodynamically stable. Though large amount of hemoperitoneum(ie, 3+) required operation, most hemooperitoeum were managed conservatively. Thus, CT findings of liver injury is helpful in the decision for the management method

  17. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka; Akagi, Kiyoshi; Uehata, Hiroshi

    1981-01-01

    In order to obtain a radioisotope (RI) tomographic image, there are various, methods, including the RCT method, Time Modulate method, and Multiple Pinhole Coded Aperture (MPCA) method and others. The MPCA method has several advantages. Using the MPCA method, there is no need to move either the detector or the patient, Furthermore, the generally used γ-camera may be used without any alterations. Due to certain problems in reconstructing the tomographic image, the use of the MPCA method in clinical practice is limited to representation of small organs (e.g. heart) using the 7-Pinhole collimator. This research presents an experimental approach to overcome the problems in reconstruction of tomographic images of large organs (organs other than the heart, such as the brain, liver, lung etc.) by introducing a reconstruction algorithm and correction software into the MPCA method. There are 2 main problems in MPCA image reconstruction: (1) Due to the rounding-off procedure, there is both point omission and shifting of point coordinates. (2) The central portion is characterized by high-counts. Both of these problems were solved by incorporating a reconstruction algorithm and a correction function. The resultant corrected tomographic image was processed using a filter derived from subjecting a PSF to a Fourier transform. Thus, it has become possible to obtain a high-quality tomographic image of large organs for clinical use. (author)

  18. Computed tomographic appearances of sternocostoclavicular hyperostosis

    Energy Technology Data Exchange (ETDEWEB)

    Chigira, Masaki; Shimizu, Toru (Gunma Univ. (Japan). Dept. of Orthopaedic Surgery)

    1989-08-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG).

  19. Computed tomographic appearances of sternocostoclavicular hyperostosis

    International Nuclear Information System (INIS)

    Chigira, Masaki; Shimizu, Toru

    1989-01-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG)

  20. Segmentation-DrivenTomographic Reconstruction

    DEFF Research Database (Denmark)

    Kongskov, Rasmus Dalgas

    such that the segmentation subsequently can be carried out by use of a simple segmentation method, for instance just a thresholding method. We tested the advantages of going from a two-stage reconstruction method to a one stage segmentation-driven reconstruction method for the phase contrast tomography reconstruction......The tomographic reconstruction problem is concerned with creating a model of the interior of an object from some measured data, typically projections of the object. After reconstructing an object it is often desired to segment it, either automatically or manually. For computed tomography (CT...

  1. Quantum probability measures and tomographic probability densities

    NARCIS (Netherlands)

    Amosov, GG; Man'ko, [No Value

    2004-01-01

    Using a simple relation of the Dirac delta-function to generalized the theta-function, the relationship between the tomographic probability approach and the quantum probability measure approach with the description of quantum states is discussed. The quantum state tomogram expressed in terms of the

  2. Breeding snow: an instrumented sample holder for simultaneous tomographic and thermal studies

    International Nuclear Information System (INIS)

    Pinzer, B; Schneebeli, M

    2009-01-01

    To study the recrystallization processes during temperature gradient metamorphism of snow, we developed a sample holder that allows applying well-defined and stable thermal gradients to a snow sample while it is scanned in an x-ray micro-tomograph. To this end, both the thermal insulation of the sample as well as image contrast and resolution of the tomography had to be optimized. We solved this conflict by using thin aluminum cylinders in combination with highly insulating foam. This design is light, does not corrupt image quality and provides very good thermal decoupling from the environment. The sample holder was instrumented to measure the effective conductivity of the snow sample and calibrated using five materials of known conductivity. Finite element simulations were consistent with the calibration measurements and gave insight into the internal temperature and heat flux fields. With this setup, geometric and thermal evolution of snow under realistic thermal boundary conditions like alternating temperature gradients can be measured

  3. Visual computed tomographic scoring of emphysema and its correlation with its diagnostic electrocardiographic sign: the frontal P vector.

    Science.gov (United States)

    Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David H

    2012-03-01

    Verticalization of the frontal P vector in patients older than 45 years is virtually diagnostic of pulmonary emphysema (sensitivity, 96%; specificity, 87%). We investigated the correlation of P vector and the computed tomographic visual score of emphysema (VSE) in patients with established diagnosis of chronic obstructive pulmonary disease/emphysema. High-resolution computed tomographic scans of 26 patients with emphysema (age, >45 years) were reviewed to assess the type and extent of emphysema using the subjective visual scoring. Electrocardiograms were independently reviewed to determine the frontal P vector. The P vector and VSE were compared for statistical correlation. Both P vector and VSE were also directly compared with the forced expiratory volume at 1 second. The VSE and the orientation of the P vector (ÂP) had an overall significant positive correlation (r = +0.68; P = .0001) in all patients, but the correlation was very strong in patients with predominant lower-lobe emphysema (r = +0.88; P = .0004). Forced expiratory volume at 1 second and ÂP had almost a linear inverse correlation in predominant lower-lobe emphysema (r = -0.92; P vertical ÂP and predominant lower-lobe emphysema reflects severe obstructive lung dysfunction. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Remacle, J.; Quoidbach, G.

    1993-01-01

    The concept of 'computerized management' of plant intervention tasks was developed by TRACTEBEL in 1983 for the Belgian power plants of ELECTRABEL. The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant in planning, organizing, and carrying out any (preventive or corrective) maintenance task. It consists of a group of interconnected functional modules acting on a unique and homogeneous data base. A short description of 3 modules is given, i.e., the 'User' Module, the 'Equipment' Module and the 'Periodic Procedure' Module. (Z.S.)

  5. Computed tomographic appearances of cherubism

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S D; Boccardi, A; Mela, F; Romagnoli, R

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression.

  6. Tomographic reconstruction of atmospheric volumes from infrared limb-imager measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ungermann, Joern

    2011-08-12

    State-of-the art nadir and limb-sounders, but also in situ measurements, do not offer the capability to highly resolve the atmosphere in all three dimensions. This leaves an observational gap with respect to small-scale structures that arise frequently in the atmosphere and that still lack a quantitative understanding. For instance, filaments and tropopause folds in the upper troposphere and lower stratosphere (UTLS) are crucial for its composition and variability. One way to achieve a highly resolved three-dimensional (3-D) picture of the atmosphere is the tomographic evaluation of limb-imager measurements. This thesis presents a methodology for the tomographic reconstruction of atmospheric constituents. To be able to deal with the large increase of observations and unknowns compared to conventional retrievals, great care is taken to reduce memory consumption and processing time. This method is used to evaluate the performance of two upcoming infrared limb-imager instruments and to prepare their missions. The first examined instrument is the infrared limb-imager on board of PREMIER (Process Exploration through Measurements of Infrared and millimetrewave Emitted Radiation), one of three remaining candidates for ESA's 7th Earth Explorer mission. Scientific goals of PREMIER are, among others, the examination of gravity waves and the quantification of processes controlling atmospheric composition in the UTLS, a region of particular importance for climate change. Simulations based on the performance requirements of this instrument deliver a vertical resolution that is slightly better than its vertical field-of-view (about 0.75 km) and a horizontal resolution of {approx}25km x 70 km. Non-linear end-to-end simulations for various gravity wave patterns demonstrate that the high 3-D resolution of PREMIER considerably extends the range of detectable gravity waves in terms of horizontal and vertical wavelength compared to previous observations. The second examined

  7. Tomographic reconstruction of atmospheric volumes from infrared limb-imager measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ungermann, Joern

    2011-08-12

    State-of-the art nadir and limb-sounders, but also in situ measurements, do not offer the capability to highly resolve the atmosphere in all three dimensions. This leaves an observational gap with respect to small-scale structures that arise frequently in the atmosphere and that still lack a quantitative understanding. For instance, filaments and tropopause folds in the upper troposphere and lower stratosphere (UTLS) are crucial for its composition and variability. One way to achieve a highly resolved three-dimensional (3-D) picture of the atmosphere is the tomographic evaluation of limb-imager measurements. This thesis presents a methodology for the tomographic reconstruction of atmospheric constituents. To be able to deal with the large increase of observations and unknowns compared to conventional retrievals, great care is taken to reduce memory consumption and processing time. This method is used to evaluate the performance of two upcoming infrared limb-imager instruments and to prepare their missions. The first examined instrument is the infrared limb-imager on board of PREMIER (Process Exploration through Measurements of Infrared and millimetrewave Emitted Radiation), one of three remaining candidates for ESA's 7th Earth Explorer mission. Scientific goals of PREMIER are, among others, the examination of gravity waves and the quantification of processes controlling atmospheric composition in the UTLS, a region of particular importance for climate change. Simulations based on the performance requirements of this instrument deliver a vertical resolution that is slightly better than its vertical field-of-view (about 0.75 km) and a horizontal resolution of {approx}25km x 70 km. Non-linear end-to-end simulations for various gravity wave patterns demonstrate that the high 3-D resolution of PREMIER considerably extends the range of detectable gravity waves in terms of horizontal and vertical wavelength compared to previous observations. The second examined instrument

  8. Radiodiagnostic system combining scintillation GKS-2 γ camera and SAORI-01 computerized unit

    International Nuclear Information System (INIS)

    Kalashnikov, S.D.; Mishchenko, S.V.; Chuprov, P.V.

    1986-01-01

    A medical radiodiagnostic system prising the GKS-2 scintillation gamma chamber and the on-line data processing system is described. The gamma chamber consists of a detector, a two-channel control console, a microprocessor system for correction of distortions,system of photographic recording of images from an oscilloscopic display, a digital display-monitor and 6 accessiory collimators with trucks. GKS-2 has the increased spatial resolution, fast response and image homogeneity. Application of GKS-2 together with the SAORI-01 specialized on-line system,comprising the measuring computerized system, the colour-graphic display controller the polarizer photographic recording device for scanning image from the display screen and a system of base software, expands substantially diagnostic possibilities of equipment

  9. Emission computed tomograph

    International Nuclear Information System (INIS)

    Hirose, Y.; Kanno, I.; Koga, K.; Miura, S.; Uemura, K.

    1981-01-01

    Emission computed tomograph wherein a pluralty of detectors surround an object to be examined so as to detect x- or gamma radiation emitted by said object. In front of each of said detectors there is provided a collimator which comprises a pair of main plates and a subsidiary plate interposed therebetween. The plates are made of a material capable of blocking penetration of the radiation therethrough and so supported as to be swingable over an angle sufficient to cover the whole of said object. The plates of all the collimators are simultaneously swung to the same side and at the same angular speed thereby to change the direction of incidence of said radiation on each of said detectors

  10. Case Report: Unusual computed tomographic features of ...

    African Journals Online (AJOL)

    A case report of a 57-year old woman who presented with signs and symptoms of intracranial mass. Computed tomographic (CT) and clinical features were unusual and suggestive of a parasaggital Meningioma. However an accurate diagnosis of a tuberculoma was made at surgery and histopathological examination.

  11. Volumetry of human taste buds using laser scanning microscopy.

    Science.gov (United States)

    Just, T; Srur, E; Stachs, O; Pau, H W

    2009-10-01

    In vivo laser scanning confocal microscopy is a relatively new, non-invasive method for assessment of oral cavity epithelia. The penetration depth of approximately 200-400 microm allows visualisation of fungiform papillae and their taste buds. This paper describes the technique of in vivo volumetry of human taste buds. Confocal laser scanning microscopy used a diode laser at 670 nm for illumination. Digital laser scanning confocal microscopy equipment consisted of the Heidelberg Retina Tomograph HRTII and the Rostock Cornea Module. Volume scans of fungiform papillae were used for three-dimensional reconstruction of the taste bud. This technique supplied information on taste bud structure and enabled measurement and calculation of taste bud volume. Volumetric data from a 23-year-old man over a nine-day period showed only a small deviation in values. After three to four weeks, phenomenological changes in taste bud structures were found (i.e. a significant increase in volume, followed by disappearance of the taste bud and appearance of a new taste bud). The data obtained indicate the potential application of this non-invasive imaging modality: to evaluate variation of taste bud volume in human fungiform papillae with ageing; to study the effects of chorda tympani nerve transection on taste bud volume; and to demonstrate recovery of taste buds in patients with a severed chorda tympani nerve who show recovery of gustatory sensibility after surgery.

  12. Time-resolved tomographic images of a relativistic electron beam

    International Nuclear Information System (INIS)

    Koehler, H.A.; Jacoby, B.A.; Nelson, M.

    1984-07-01

    We obtained a sequential series of time-resolved tomographic two-dimensional images of a 4.5-MeV, 6-kA, 30-ns electron beam. Three linear fiber-optic arrays of 30 or 60 fibers each were positioned around the beam axis at 0 0 , 61 0 , and 117 0 . The beam interacting with nitrogen at 20 Torr emitted light that was focused onto the fiber arrays and transmitted to a streak camera where the data were recorded on film. The film was digitized, and two-dimensional images were reconstructed using the maximum-entropy tomographic technique. These images were then combined to produce an ultra-high-speed movie of the electron-beam pulse

  13. 45 CFR 307.25 - Review and certification of computerized support enforcement systems.

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS § 307.25 Review and certification of computerized support enforcement systems. The Office will review, assess and inspect the... 45 Public Welfare 2 2010-10-01 2010-10-01 false Review and certification of computerized support...

  14. Bone scan: A useful test for evaluating patients with low back pain

    International Nuclear Information System (INIS)

    Collier, B.D.; Kir, K.M.; Mills, B.J.A.; Patel, N.C.; Pochis, W.T.; Onsel, C.; Liu, Y.; Turoglu, H.T.

    1990-01-01

    For many years it has been known that the sensitivity of bone scanning to the presence of destructive bony lesions favors its use in screning for bone metastases and osteomyelitis. More recently bone scanning has been routinely employed in evaluating benign skeletal pathology that may be the cause of low back pain. Bone scanning can play an important part identifying the cause of pain, clarifying the significance of radiographic findings, and evaluating the results of spinal surgery. This expansion of the role of nuclear medicine in diagnosing and managing low back pain is based in part upon novel diagnostic applications of 99m Tc-methylene diphosphonate, a radiopharmaceutical that has been available for over 15 years. Equally important for this development, however, has been the recent availability of SPECT, a tomographic imaging technique that can be used to display the spine in a series of 6- to 8-mm thick sections. Slightly more than one-half of newly purchased gamma cameras are rotating systems suitable for bone SPECT studies. Thus, many community hospitals can now perform state-of-the-art bone scans for low back pain. (orig.)

  15. Demonstration of cerebral abnormalities in cocaine abusers with SPECT perfusion brain scans

    International Nuclear Information System (INIS)

    Nagel, J.S.; Tumeh, S.S.; English, R.J.; Moore, M.; Lee, V.W.; Holman, L.B.

    1989-01-01

    This paper reports I-123 isopropyl iodoamphetamine (IMP) single-photon emission CT (SPECT) brain scans performed on cocaine users to investigate the effects of cocaine on the cerebral perfusion in a manner similar to previous CT, angiographic and positron-emission tomographic (PET) studies. Ten asymptomatic or mildly symptomatic cocaine users, two users with major neurovascular complications, and five normal subjects were studied with IMP SPECT. Rotating-brain images of the cerebral IMP uptake were displayed by using a distance-weighted surface-projection technique and were visually analyzed for focal cortical perfusion deficits. Eleven cocaine users had multiple scattered cortical IMP defects. Frontal lobe defects were most prominent. One user had confluent defects resembling swiss cheese. Concurrent CT scans available in nine patients were negative in seven and showed infarcts in two. No similar focal findings were visible in normals

  16. An introduction to the tomographic picture of quantum mechanics

    International Nuclear Information System (INIS)

    Ibort, A; Man'ko, V I; Marmo, G; Simoni, A; Ventriglia, F

    2009-01-01

    Starting from the famous Pauli problem on the possibility of associating quantum states with probabilities, the formulation of quantum mechanics in which quantum states are described by fair probability distributions (tomograms, i.e. tomographic probabilities) is reviewed in a pedagogical style. The relation between the quantum state description and the classical state description is elucidated. The difference between those sets of tomograms is described by inequalities equivalent to a complete set of uncertainty relations for the quantum domain and to non-negativity of probability density on phase space in the classical domain. The intersection of such sets is studied. The mathematical mechanism that allows us to construct different kinds of tomographic probabilities like symplectic tomograms, spin tomograms, photon number tomograms, etc is clarified and a connection with abstract Hilbert space properties is established. The superposition rule and uncertainty relations in terms of probabilities as well as quantum basic equations like quantum evolution and energy spectra equations are given in an explicit form. A method to check experimentally the uncertainty relations is suggested using optical tomograms. Entanglement phenomena and the connection with semigroups acting on simplexes are studied in detail for spin states in the case of two-qubits. The star-product formalism is associated with the tomographic probability formulation of quantum mechanics.

  17. XRF newsletter. No. 6, August 2003

    International Nuclear Information System (INIS)

    2003-08-01

    This periodical XRF Newsletter is to inform the XRF laboratories in IAEA Member States on recent developments in the field of XRF spectrometry and to exchange views on fundamental and applied aspects of sampling, sample preparation, instrumentation, quality control, etc. A few selected examples of the recent activities in the IAEA XRF Laboratory and its results in the field of XRF are presented: Application of X-ray fluorescence techniques for the determination of hazardous and essential trace elements in environmental and biological materials; X-ray fluorescence analysis and computerized tomographic imaging with a laboratory micro-beam scanning spectrometer; Data acquisition software for X-ray microprobe; XRF Laboratories Database; Collaborative Bronze Art Project

  18. Determination of gonad, eye and bone marrow doses with EMI-5005 head and whole body scans

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Iwata, Takeo; Furuya, Yoshiro; Maruyama, Takashi; Hashizume, Tadashi.

    1979-01-01

    Dose determinations of tissues and organs during head and whole body scanning with an EMI computed tomographic equipment have been carried out using a Rando woman phantom. The surface dose on the phantom was measured with a Sakura lith Contact film dosimeter system. The absorbed doses in the eyes, thyroids, ovaries and the bone marrow were measured with a thermoluminescent dosimeter. The resultant surface doses for head scanning were 2.8 rad (28 mGy) per scan at maximum and 0.26 rad (2.6 mGy) per scan at minimum, and the doses for whole body scanning were 2.7 rad (27 mGy) per scan at maximum and 0.1 rad (1.0 mGy) per scan at minimum. For the complete gynecological scanning consisting of 8 slices, the eye, thyroid, ovary and the bone marrow dose was 2.4 mrad (24 μGy), 3.5 mrad (35 μGy), 500 mrad (5 mGy) and 225 mrad (2.25 mGy), respectively. And, for a typical head scanning consisting of 5 slices, the eye, thyroid, ovary and the bone marrow dose was 1400 mrad (14 mGy), 46 mrad (460 μGy), 0.60 mrad (6 μGy) and 73 mrad (730 μGy), respectively. (author)

  19. The use of tomographic techniques in the mineral processing Industry. A review

    International Nuclear Information System (INIS)

    Witika, L.K.; Jere, E.H.

    2002-01-01

    Process tomographic techniques may be used to analyse the internal state of most of the multiphase process engineering systems such as material segregation in a reactor multiphase flow in pipes and the spatial resolution of mineral grains in multiphase particles. These techniques include radiation computed tomography (X-ray or ray), electrical methods(capacitance, impedance and inductive tomography) positron emission tomography,optical tomography, microwave tomography, acoustic tomographical methods and many more. Many potential applications exist for process tomographic instrumentation for quantitative analysis and fault-detection purposes. Amongst these, electrical methods are widely used for those mineral processes deserving particular attention such as dense-medium separation, hydro cyclones, flotation cells and columns, gas-liquid absorbers, solvent extraction and other liquid-liquid processes, filtration and other solid-liquid processes, grinding mills (both dry and wet, conveyors and hoppers). Development in on-line measurement instrumentation now allow direct observation of the behaviour of fluids inside mineral separation equipment. This offers the possibility to acquire process data to enable models to be devised, to verify theoretical computational fluid dynamics predictions and control of various unit processes. In this review, the most important tomographic sensing methods are reviewed. Examples of the implementation of some electrical methods are illustrated. (authors)

  20. Visual servoing in medical robotics: a survey. Part II: tomographic imaging modalities--techniques and applications.

    Science.gov (United States)

    Azizian, Mahdi; Najmaei, Nima; Khoshnam, Mahta; Patel, Rajni

    2015-03-01

    Intraoperative application of tomographic imaging techniques provides a means of visual servoing for objects beneath the surface of organs. The focus of this survey is on therapeutic and diagnostic medical applications where tomographic imaging is used in visual servoing. To this end, a comprehensive search of the electronic databases was completed for the period 2000-2013. Existing techniques and products are categorized and studied, based on the imaging modality and their medical applications. This part complements Part I of the survey, which covers visual servoing techniques using endoscopic imaging and direct vision. The main challenges in using visual servoing based on tomographic images have been identified. 'Supervised automation of medical robotics' is found to be a major trend in this field and ultrasound is the most commonly used tomographic modality for visual servoing. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Computed tomographic study of 50 patients with hypodense hepatic injuries in childhood

    International Nuclear Information System (INIS)

    Pereira, Ines Minniti Rodrigues; Alvares, Beatriz Regina; Baracat, Jamal; Martins, Daniel Lahan; Pereira, Ricardo Minniti Rodrigues

    2006-01-01

    Objective: To describe the different tomographic findings in hypodense hepatic lesions in children and its differential diagnosis. Materials and methods: computed tomographic studies were obtained from 50 patients (age range: 0-16 years) with low-density liver lesions previously diagnosed by ultrasound. Images were made before and after administration of intravenous contrast medium. Image findings were analyzed and afterwards correlated with anatomopathological diagnosis. Results: forty-seven of 50 cases were confirmed, 30 by anatomopathological diagnosis. Most of then were benign lesions, hemangioma in 20%. Such lesions presented a homogeneous contrast absorption, mainly at the delayed phase, differing from malignant lesions. Metastasis was the most frequently found malignant lesion (18%). Conclusion: computed tomographic study is of great value in complementing the diagnosis of hypodense hepatic lesions in children, and must follow ultrasound diagnosis as a routine procedure. (author)

  2. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    International Nuclear Information System (INIS)

    Staton, R J; Pazik, F D; Nipper, J C; Williams, J L; Bolch, W E

    2003-01-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult

  3. Computerized photogrammetry used to calculate the brow position index.

    Science.gov (United States)

    Naif-de-Andrade, Naif Thadeu; Hochman, Bernardo; Naif-de-Andrade, Camila Zirlis; Ferreira, Lydia Masako

    2012-10-01

    The orbital region is of vital importance to facial expression. Brow ptosis, besides having an impact on facial harmony, is a sign of aging. Various surgical techniques have been developed to increase the efficacy of brow-lift surgery. However, no consensus method exists for an objective measurement of the eyebrow position due to the curvature of the face. Therefore, this study aimed to establish a method for measuring the eyebrow position using computerized photogrammetry. For this study, 20 orbital regions of 10 volunteers were measured by direct anthropometry using a digital caliper and by indirect anthropometry (computerized photogrammetry) using standardized digital photographs. Lines, points, and distances were defined based on the position of the anthropometric landmarks endocanthion and exocanthion and then used to calculate the brow position index (BPI). Statistical analysis was performed using Student's t test with a significance level of 5 %. The BPI values obtained by computerized photogrammetric measurements did not differ significantly from those obtained by direct anthropometric measurements (p > 0.05). The mean BPI was 84.89 ± 10.30 for the computerized photogrammetric measurements and 85.27 ± 10.67 for the direct anthropometric measurements. The BPI defined in this study and obtained by computerized photogrammetry is a reproducible and efficient method for measuring the eyebrow position. This journal requires that authors assign a level of evidence to each article.

  4. Hemispherical Scanning Imaging DOAS: Resolving nitrogen dioxide in the urban environment

    Science.gov (United States)

    Leigh, R. J.; Graves, R. R.; Lawrence, J.; Faloon, K.; Monks, P. S.

    2012-12-01

    Imaging DOAS techniques have been used for nitrogen dioxide and sulfer dioxide for a number of years. This presentation describes a novel system which images concentrations of nitrogen dioxide by scanning an imaging spectrometer 360 degrees azimuthally, covering a region from 5 degrees below the horizon, to the zenith. The instrument has been built at the University of Leicester (UK), on optical designs by Surrey Satellite Technologies Ltd, and incorporates an Offner relay with Schwarzchild fore-optics, in a rotating mount. The spectrometer offers high fidelity spectroscopic retrievals of nitrogen dioxide as a result of a reliable Gaussian line shape, zero smile and low chromatic aberration. The full hemispherical scanning provides complete coverage of nitrogen dioxide concentrations above approximately 5 ppbv in urban environments. Through the use of multiple instruments, the three-dimensional structure of nitrogen dioxide can be sampled and tomographically reconstructed, providing valuable information on nitrogen dioxide emissions and downwind exposure, in addition to new understanding of boundary layer dynamics through the use of nitrogen dioxide as a tracer. Furthermore, certain aerosol information can be retrieved through absolute intensity measurements in each azimuthal direction supplemented by traditional techniques of O4 spectroscopy. Such measurements provide a new tool for boundary layer measurement and monitoring at a time when air quality implications on human health and climate are under significant scrutiny. This presentation will describe the instrument and tomographic potential of this technique. First measurements were taken as part of the international PEGASOS campaign in Bologna, Italy. Results from these measurements will be shown, including imaging of enhanced NO2 in the Bologna urban boundary layer during a severe thunderstorm. A Hemispherical Scanning Imaging DOAS instrument operating in Bologna, Italy in June 2012. Visible in the background

  5. MCPT: A Monte Carlo code for simulation of photon transport in tomographic scanners

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Gardner, R.P.; Verghese, K.

    1990-01-01

    MCPT is a special-purpose Monte Carlo code designed to simulate photon transport in tomographic scanners. Variance reduction schemes and sampling games present in MCPT were selected to characterize features common to most tomographic scanners. Combined splitting and biasing (CSB) games are used to systematically sample important detection pathways. An efficient splitting game is used to tally particle energy deposition in detection zones. The pulse height distribution of each detector can be found by convolving the calculated energy deposition distribution with the detector's resolution function. A general geometric modelling package, HERMETOR, is used to describe the geometry of the tomographic scanners and provide MCPT information needed for particle tracking. MCPT's modelling capabilites are described and preliminary experimental validation is presented. (orig.)

  6. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  7. Comparative evaluation of coronal images of the middle ear visualized by CT scan and polytomography

    International Nuclear Information System (INIS)

    Sugiyama, Masao; Nakai, Yoshiaki; Cho, Kansei; Tanabe, Kyoji; Inoue, Yuichi; Onoyama, Yasuto

    1982-01-01

    We retrospectively analysed the coronal images of the middle ear obtained by multidirectional tomography (polytomography) and computed tomography (CT) in 40 patients. Although CT was capable of demonstrating water density in the middle ear more clearly than polytomography and of delineating a lesion extending even outside of the petrous bone, the diagnostic capability was not much different between the two tomographic techniques. On the other hand, coronal CT scan has a disadvantage in that it usually has to be performed during hyperextension of the neck or while patients are in an uncomfortable hanging head position. We think that CT scan should be utilized only in case with a lesion extending beyond the petrous bone and/or is not well visualized by polytomography. (author)

  8. Results of CT brain examinations in cerebrovascular emergency. [computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pinta, Z; Dolansky, J; Sorfova, J; Jerie, T

    1987-07-01

    Experience is briefly reported with CT (computerized tomography) diagnosis of cerebrovascular emergencies. It is pointed out that the introduction of computerized tomography greatly improved and made more accurate the diagnosis of focal ischemias and revealed significant differences in the foci of ischemia in hypertension patients and atherosclerosis patients without hypertension, and showed a higher incidence of intracerebral and subarachnoidal hemorrhages than previously thought. It is believed that knowledge gained thanks to CT (computerized tomography) will be of benefit to the primary and secondary prevention of cerebrovascular ischemias. (L.O.). 1 fig., 5 refs.

  9. Tomographic examination table

    International Nuclear Information System (INIS)

    Redington, R.W.; Henkes, J.L.

    1979-01-01

    Equipment is described for positioning and supporting patients during tomographic mammography using X-rays. The equipment consists of a table and fabric slings which permit the examination of a downward, pendant breast of a prone patient by allowing the breast to pass through a aperture in the table into a fluid filled container. The fluid has an X-ray absorption coefficient similar to that of soft human tissue allowing high density resolution radiography and permitting accurate detection of breast tumours. The shape of the equipment and the positioning of the patient allow the detector and X-ray source to rotate 360 0 about a vertical axis through the breast. This permits the use of relatively simple image reconstruction algorithms and a divergent X-ray geometry. (UK)

  10. Photon emission tomographic apparatus and method

    International Nuclear Information System (INIS)

    Blum, A.S.

    1983-01-01

    Tomographic imaging system employs large area, collimated scintillation detector rotated around radiation emitting subject. Detector support rotates with an inner ring inside a stationary outer ring. Counterbalanced detector support arm is forced by spring action to cause collimator face to follow body contour as detector rotates around the body, thereby reducing collimator to subject distance to improve system resolution. Includes adjustable subject support system

  11. Study on computerized presentation of emergency procedures of a nuclear plant (step 2). The guidelines of the prototype of the computerized procedure presentation system

    International Nuclear Information System (INIS)

    Niwa, Yuji; Hollnagel, E.; Iwaki, Toshio.

    1995-01-01

    New methods of information presentation and interface design are changing the working conditions in the modern Nuclear Power Plant (NPP) control room. One area receiving considerable attention is that of Emergency Operating Procedures (EOPs), which plays an essential role in NPPs. Conventionally procedures are presented in a hard copy form. However developments in information technology have offered new opportunities for the computerization of such procedures. Consideration for the first stage of computerization should be focused upon the presentation of procedures. The specification of the computerized presentation of procedures is discussed with respect to the issues which were central to the project: navigation through procedures; formatting and presentation of procedures; and process monitoring. Issues that would be included in more advanced systems, such as help and explanation facilities features, and process linking, are also discussed. This paper deals with the specific design guidelines that were implemented for the computerization of procedure presentation. Issues of principal concern that were identified from this experience are highlighted, such as the relationship between procedure presentation and format; the registration of progress through a procedure; compensation for the limitations of computer displays versus printed documents; and the way in which the added capabilities of computerized presentation can be generally utilized in the operators' working environment. (author)

  12. Computerization of the safeguards analysis decision process

    International Nuclear Information System (INIS)

    Ehinger, M.H.

    1990-01-01

    This paper reports that safeguards regulations are evolving to meet new demands for timeliness and sensitivity in detecting the loss or unauthorized use of sensitive nuclear materials. The opportunities to meet new rules, particularly in bulk processing plants, involve developing techniques which use modern, computerized process control and information systems. Using these computerized systems in the safeguards analysis involves all the challenges of the man-machine interface experienced in the typical process control application and adds new dimensions to accuracy requirements, data analysis, and alarm resolution in the regulatory environment

  13. Computerized tomography in the diagnosis of hyperparathyroidism

    International Nuclear Information System (INIS)

    Sobota, J.; Girl, J.; Sotornik, I.; Kocandrle, V.

    1990-01-01

    Long-term experience in the application of computerized tomography to the diagnosis of hyperparathyroidism is summarized. Based on a large number of examinations (164) of parathyroid glands associated with the possibility of verification and comparison with the results of ultrasonography and other imaging methods, the potential of computerized tomography in the diagnosis of hyperparathyroidism and its advantages and limitations are summarized. It is concluded that owing to its high diagnostic precision, this technique can be regarded reliable in detecting enlarged parathyroid glands. (author). 11 figs., 1 tab., 19 refs

  14. Industrial dynamic tomographic reconstruction; Reconstrucao tomografica dinamica industrial

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Eric Ferreira de

    2016-07-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  15. Twelve years nuclear medicine - results and outlook - illustrated by 7414 cerebral scintigrams

    International Nuclear Information System (INIS)

    Klaeger, R.

    1981-01-01

    It is a fact that until the invention of computerized tomography, scintiscanning was an excellent method for diagnosing tumours, metastases, vascular processes, inflammations and traumatic lesions. Now even the differential diagnosis is possible, and also follow-up examinations are often carried out. On the basis of the 7414 considered and studied scintigrams we came to the positive result that in most cases with deliberate questions directed to specific facts, this examination procedure was applied. Scintigraphy can be considered as the predecessor of computerized tomography. With respect to differential diagnostics the following can be said: Cerebral scintigraphy measures in cases of cerebral lesions only masses, whereas the computerized tomograph permits within certain limits even the differentiation between lesion and perifocal oedema. The tomographs of the last generation even differentiate between white and grey cerebral substance. Nevertheless, the residual domaine of scintigraphy remains untouched: the patients with non-focal symptoms, including headaches, general behaviour disorders and psychiatric processes. (orig./MG) [de

  16. Full-angle tomographic phase microscopy of flowing quasi-spherical cells.

    Science.gov (United States)

    Villone, Massimiliano M; Memmolo, Pasquale; Merola, Francesco; Mugnano, Martina; Miccio, Lisa; Maffettone, Pier Luca; Ferraro, Pietro

    2017-12-19

    We report a reliable full-angle tomographic phase microscopy (FA-TPM) method for flowing quasi-spherical cells along microfluidic channels. This method lies in a completely passive optical system, i.e. mechanical scanning or multi-direction probing of the sample is avoided. It exploits the engineered rolling of cells while they are flowing along a microfluidic channel. Here we demonstrate significant progress with respect to the state of the art of in-flow TPM by showing a general extension to cells having almost spherical shapes while they are flowing in suspension. In fact, the adopted strategy allows the accurate retrieval of rotation angles through a theoretical model of the cells' rotation in a dynamic microfluidic flow by matching it with phase-contrast images resulting from holographic reconstructions. So far, the proposed method is the first and the only one that permits to get in-flow TPM by probing the cells with full-angle, achieving accurate 3D refractive index mapping and the simplest optical setup, simultaneously. Proof of concept experiments were performed successfully on human breast adenocarcinoma MCF-7 cells, opening the way for the full characterization of circulating tumor cells (CTCs) in the new paradigm of liquid biopsy.

  17. Sequential computerized tomography changes and related final outcome in severe head injury patients

    International Nuclear Information System (INIS)

    Lobato, R.D.; Gomez, P.A.; Alday, R.

    1997-01-01

    The authors analyzed the serial computerized tomography (CT) findings in a large series of severely head injured patients in order to assess the variability in gross intracranial pathology through the acute posttraumatic period and determine the most common patterns of CT change. A second aim was to compare the prognostic significance of the different CT diagnostic categories used in the study (Traumatic Coma Data Bank CT pathological classification) when gleaned either from the initial (postadmission) or the control CT scans, and determine the extent to which having a second CT scan provides more prognostic information than only one scan. 92 patients (13.3 % of the total population) died soon after injury. Of the 587 who survived long enough to have at least one control CT scan 23.6 % developed new diffuse brain swelling, and 20.9 % new focal mass lesions most of which had to be evacuated. The relative risk for requiring a delayed operation as related to the diagnostic category established by using the initial CT scans was by decreasing order: diffuse injury IV (30.7 %), diffuse injury III (30.5 %), non evacuated mass (20 %), evacuated mass (20.2 %), diffuse injury II (12.1 %), and diffuse injury I (8.6 %). Overall, 51.2 % of the patients developed significant CT changes (for worse or better) occurring either spontaneously or following surgery, and their final outcomes were more closely related to the control than to the initial CT diagnoses. In fact, the final outcome was more accurately predicted by using the control CT scans (81.2 % of the cases) than by using the initial CT scans (71.5 % of the cases only). Since the majority of relevant CT changes developed within 48 hours after injury a pathological categorization made by using an early control CT scan seems to be most useful for prognostic purposes. Prognosis associated with the CT pathological categories used in the study was similar independently of the moment of the acute posttraumatic period at which

  18. Evaluation and optimization of the High Resolution Research Tomograph (HRRT)

    International Nuclear Information System (INIS)

    Knoess, C.

    2004-01-01

    Positron Emission Tomography (PET) is an imaging technique used in medicine to determine qualitative and quantitative metabolic parameters in vivo. The High Resolution Research Tomograph (HRRT) is a new high resolution tomograph that was designed for brain studies (312 mm transaxial field-of-view (FOV), 252 mm axial FOV). The detector blocks are arranged in a quadrant sharing design and consist of two crystal layers with dimensions of 2.1 mm x 2.1 mm x 7.5 mm. The main detector material is the newly developed scintillator lutetium oxyorthosilicate (LSO). Events from the different crystal layers are distinguished by Pulse Shape Discrimination (PSD) to gain Depth of Interaction (DOI) information. This will improve the spatial resolution, especially at the edges of the FOV. A prototype of the tomograph was installed at the Max-Planck Institute for Neurological Research in Cologne, Germany in 1999 and was evaluated with respect to spatial resolution, sensitivity, scatter fraction, and count rate behavior. These performance measurements showed that this prototype provided a spatial resolution of around 2.5 mm in a volume big enough to contain the human brain. A comparison with a single layer HRRT prototype showed a 10% worsening of the resolution, despite the fact that DOI was used. Without DOI, the resolution decreased considerably. The sensitivity, as measured with a 22 Na point source, was 46.5 cps/kBq for an energy window of 350-650 keV and 37.9 cps/kBq for an energy window of 400-650 keV, while the scatter fractions were 56% for 350-650 keV and 51% for 400-650 keV, respectively. A daily quality check was developed and implemented that uses the uniform, natural radioactive background of the scintillator material LSO. In 2001, the manufacturer decided to build a series of additional HRRT scanners to try to improve the design (detector electronics, transmission source design, and shielding against out-of-FOV activity) and to eliminate problems (difficult detector

  19. Visual information transfer. 1: Assessment of specific information needs. 2: The effects of degraded motion feedback. 3: Parameters of appropriate instrument scanning behavior

    Science.gov (United States)

    Comstock, J. R., Jr.; Kirby, R. H.; Coates, G. D.

    1984-01-01

    Pilot and flight crew assessment of visually displayed information is examined as well as the effects of degraded and uncorrected motion feedback, and instrument scanning efficiency by the pilot. Computerized flight simulation and appropriate physiological measurements are used to collect data for standardization.

  20. Computerized systems of NPP operators support. (Psychological problems)

    International Nuclear Information System (INIS)

    Mashin, V.A.

    1995-01-01

    Operator psychological problems arising in the work with NPP operators support computerized systems (OSCS) are considered. The conclusion is made that the OSCS intellectual application will bring the operator into dangerous dependence on his computerized assistant. To avoid this danger it is necessary by creation of the OSCS to divide specially the tasks areas of the operator and OSCS in order to assure the active role of the operator in the NPP control

  1. Tomographic thallium-201 myocardial perfusion scintigrams after maximal coronary artery vasodilation with intravenous dipyridamole: comparison of qualitative and quantitative approaches

    International Nuclear Information System (INIS)

    Francisco, D.A.; Collins, S.M.; Go, R.T.; Ehrhardt, J.C.; Van Kirk, O.C.; Marcus, M.L.

    1982-01-01

    Eighty-six patients had thallium-201 ( 201 Tl) myocardial perfusion scintigrams after intense coronary artery dilation with i.v. dipyridamole. Tomographic and planar 201 Tl scintigrams were obtained in each patient. Tomographic scintigrams were interpreted using quantitative or visual criteria; planar scintigrams were assessed using visual criteria only. When visual criteria were used, interobserver variability was 40% for tomographic scintigrams and 44% for planar scintigrams. In the 24 patients with normal or nonsignificant CAD, quantitative analysis of the tomograms (range approach) indicated that one of 24 (4%) had a positive image (specificity 96%%); in contrast, when visual criteria were used to interpret the tomographic or planar 201 Tl scintigrams, eight of 24 (33%) had positive scintigrams (specificity 67%). In the 51 abnormal patients, the sensitivity of detecting CAD was 46 of 51 (90%) for tomographic scintigrams interpreted quantitatively, 39 of 51 (76%) for tomographic scintigrams interpreted visually and 41 of 51 (80%) for planar scintigrams assessed visually. The tomographic imaging procedure (quantitative interpretation) also demonstrated a high sensitivity (89%) and specificity (100%) in 28 patients (10 normal and 18 CAD), with a clinical diagnosis of unstable angina pectoris. Overall, the predictive accuracy of an abnormal scintigram with quantitative tomographic imaging (98%) was significantly better (p<0.05) than either qualitative planar or pinhole imaging

  2. Analysis of factors influencing the integrated bolus peak timing in contrast-enhanced brain computed tomographic angiography

    International Nuclear Information System (INIS)

    Son, Soon Yong; Choi, Kwan Woo; Jeong, Hoi Woun; Jang, Seo Goo; Jung, Jae Young; Yun, Jung Soo; Kim, Ki Won; Lee, Young Ah; Son, Jin Hyun; Min, Jung Whan

    2016-01-01

    The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast- enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was 716.53 mGy·cm and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination

  3. Conceptual design of a compact positron tomograph for prostateimaging

    Energy Technology Data Exchange (ETDEWEB)

    Huber, J.S.; Derenzo, S.E.; Qi, J.; Moses, W.W.; Huesman, R.H.; Budinger, T.F.

    2000-11-04

    We present a conceptual design of a compact positron tomograph for prostate imaging using a pair of external curved detector banks, one placed above and one below the patient. The lower detector bank is fixed below the patient bed, and the top bank adjusts vertically for maximum sensitivity and patient access. Each bank is composed of 40conventional block detectors, forming two arcs (44 cm minor, 60 cm major axis) that are tilted to minimize attenuation and positioned as close as possible to the patient to improve sensitivity. The individual detectors are angled to point towards the prostate to minimize resolution degradation in that region. Inter-plane septa extend 5 cm beyond the scintillator crystals to reduce random and scatter backgrounds. A patient is not fully encircled by detector rings in order to minimize cost,causing incomplete sampling due to the side gaps. Monte Carlo simulation (including random and scatter) demonstrates the feasibility of detecting a spherical tumor of 2.5 cm diameter with a tumor to background ratio of2:1, utilizing the number of events that should be achievable with a6-minute scan after a 10 mCi injection (e.g., carbon-11 choline or fluorine-18 fluorocholine).

  4. Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics

    Science.gov (United States)

    Yu, Tao; Cai, Weiwei; Liu, Yingzheng

    2018-04-01

    Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.

  5. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Quoidbach, G.

    2004-01-01

    The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant or of any other complex industrial facility (chemical industries, refineries, and so on) in planning, organizing, and carrying out any (preventive or corrective) maintenance task. This 'Computerized Management of Plant Intervention Tasks' is organized around a data base of all plant components in the facility that might be subjected to maintenance or tagout. It allows to manage, by means of intelligent and configurable 'mail service', the course of the intervention requests as well as various treatments of those requests, in a safe and efficient way, adapted to each particular organization. The concept of 'Computerized Management' of plant intervention tasks was developed by BELGATOM in 1983 for the Belgian nuclear power plants of ELECTRABEL. A first implementation of this concept was made at that time for the Doel NPP under the name POPIT (Programming Of Plant Intervention Tasks). In 1988, it was decided to proceed to a functional upgrade of the application, using advanced software and hardware techniques and products, and to realize a second implementation in the Tihange NPP under the name ACM (Application Consignation Maintenance). (author)

  6. Influence of Heat Treatment of Nickel-Titanium Rotary Endodontic Instruments on Apical Preparation: A Micro-Computed Tomographic Study.

    Science.gov (United States)

    de Almeida, Bernardo Corrêa; Ormiga, Fabíola; de Araújo, Marcos César Pimenta; Lopes, Ricardo Tadeu; Lima, Inayá Corrêa Barbosa; dos Santos, Bernardo Camargo; Gusman, Heloisa

    2015-12-01

    The aim of this study was to make a 3-dimensional comparison of the canal transportation and changes in apical geometry using micro-computed tomographic imaging after canal preparation with K3 (SybronEndo, Orange, CA) and K3XF (SybronEndo) file systems. Twenty-eight mandibular molars were randomly divided into 2 groups according to the rotary system used in instrumentation: K3 or K3XF. The specimens were scanned by micro-computed tomographic imaging before and after instrumentation. Images before and after instrumentation from each group were compared with regard to canal volume, surface area, and structure model index (SMI) (paired t test, P instrumentation, the canals from each group were compared regarding the changes in volume, surface area, SMI, and canal transportation in the last 4 apical mm (t test, P Instrumentation with the 2 rotary systems significantly changed the canal volume, surface area, and SMI (P instrument types concerning these parameters (P > .05). There were no significant differences between the 2 groups with regard to canal transportation in the last 4 apical mm (P > .05). Both rotary systems showed adequate canal preparations with reduced values of canal transportation. Heat treatment did not influence changes in root canal geometry in the apical region. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Sub-Airy Confocal Adaptive Optics Scanning Ophthalmoscopy.

    Science.gov (United States)

    Sredar, Nripun; Fagbemi, Oladipo E; Dubra, Alfredo

    2018-04-01

    To demonstrate the viability of improving transverse image resolution in reflectance scanning adaptive optics ophthalmoscopy using sub-Airy disk confocal detection. The foveal cone mosaic was imaged in five human subjects free of known eye disease using two custom adaptive optics scanning light ophthalmoscopes (AOSLOs) in reflectance with 7.75 and 4.30 mm pupil diameters. Confocal pinholes of 0.5, 0.6, 0.8, and 1.0 Airy disk diameters (ADDs) were used in a retinal conjugate plane before the light detector. Average cone photoreceptor intensity profile width and power spectrum were calculated for the resulting images. Detected energy using a model eye was recorded for each pinhole size. The cone photoreceptor mosaic is better resolved with decreasing confocal pinhole size, with the high spatial frequency content of the images enhanced in both the large- and small-pupil AOSLOs. The average cone intensity profile width was reduced by ∼15% with the use of a 0.5 ADD pinhole when compared to a 1.0 ADD, with an accompanying reduction in signal greater than a factor of four. The use of sub-Airy disk confocal pinhole detection without increasing retinal light exposure results in a substantial improvement in image resolution at the cost of larger than predicted signal reduction. Improvement in transverse resolution using sub-Airy disk confocal detection is a practical and low-cost approach that is applicable to all point- and line-scanning ophthalmoscopes, including optical coherence tomographers.

  8. Determination of spatial resolution of positron emission tomograph of clear PET-XPAD3/CT system

    Energy Technology Data Exchange (ETDEWEB)

    Olaya D, H.; Martinez O, S. A. [Universidad Pedagogica y Tecnologica de Colombia, Grupo de Fisica Nuclear Aplicada y Simulacion, 150003 Tunja, Boyaca (Colombia); Morel, C. [Centre de Physique des Particules de Marseille, ImXgam Group, 13009 Marseille (France); Castro, H. F. [Universidad Nacional de Colombia, Physics Department, Carrera 45 No. 26-85, Bogota (Colombia)

    2016-10-15

    Based on the National Electrical Manufacturers Association (Nema), using the Amine software to construction of sinograms and using a radioactive source {sup 22}Na that emitting positrons were made calculations for determine spatial resolution of ring array system of phoswich detectors of positron emission tomograph included in the Clear PET-XPAD3/CT prototype for small animals made in the laboratories of CCPM and whose project is led by the research group ImXgam. The radioactive source {sup 22}Na approximately 9 MBq of activity, with spherical shape and diameter of 0.57 mm immersed in a plexiglas disc was located at the geometric center of tomographic system with a Field of View (Fov) of 35 mm in the axial and transverse directions. Displacements of radioactive source were performed on the three cartesian axes and was rebuilt a sinogram for each axis. The shape of sinogram allow describe the correct position and the maximum efficiency of each detector. Subsequently, was carried out a scanning in each one of three spatial axes taking an enough distance covering the dimensions of radioactive source, were recorded data for each one of phoswich detector crystals which are aligned in the axis of movement. The process was repeated for other axes and then was offsetting the radioactive source with respect to the Fov and were calculated FWHM (Full Width at Half Maximum) and FWTM (Full Width at Tenth Maximum) values and performing statistics of these values with parabolic fitting, the latter setting allows to obtain parameters of spatial resolution of system. (Author)

  9. Determination of spatial resolution of positron emission tomograph of clear PET-XPAD3/CT system

    International Nuclear Information System (INIS)

    Olaya D, H.; Martinez O, S. A.; Morel, C.; Castro, H. F.

    2016-10-01

    Based on the National Electrical Manufacturers Association (Nema), using the Amine software to construction of sinograms and using a radioactive source "2"2Na that emitting positrons were made calculations for determine spatial resolution of ring array system of phoswich detectors of positron emission tomograph included in the Clear PET-XPAD3/CT prototype for small animals made in the laboratories of CCPM and whose project is led by the research group ImXgam. The radioactive source "2"2Na approximately 9 MBq of activity, with spherical shape and diameter of 0.57 mm immersed in a plexiglas disc was located at the geometric center of tomographic system with a Field of View (Fov) of 35 mm in the axial and transverse directions. Displacements of radioactive source were performed on the three cartesian axes and was rebuilt a sinogram for each axis. The shape of sinogram allow describe the correct position and the maximum efficiency of each detector. Subsequently, was carried out a scanning in each one of three spatial axes taking an enough distance covering the dimensions of radioactive source, were recorded data for each one of phoswich detector crystals which are aligned in the axis of movement. The process was repeated for other axes and then was offsetting the radioactive source with respect to the Fov and were calculated FWHM (Full Width at Half Maximum) and FWTM (Full Width at Tenth Maximum) values and performing statistics of these values with parabolic fitting, the latter setting allows to obtain parameters of spatial resolution of system. (Author)

  10. X-ray exposure dose for the gonadal gland by the examination of computerized tomography and its protection

    International Nuclear Information System (INIS)

    Moriuchi, Iwao; Kaiya, Hisanori; Hirata, Toshifumi; Asada, Shuichi

    1978-01-01

    Computerized tomography (CT) is very useful for neuroradiological examination, and so it may possibly be used for screening tests. But x-ray exposure dose by a examination of CT is considerable, especially for the male gonadal gland. This study showed that the dose from a complete CT examination of 10 - 15 scans for a male gonadal gland was about 1,800 times more than a single plain neuroradiography. But by only a 0.07 mm lead equivalent protecter, the exposure dose resulting from CT for a gonadal gland could be reduced to 0.0 mrad. (auth.)

  11. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  12. Constraining fault interpretation through tomographic velocity gradients: application to northern Cascadia

    Directory of Open Access Journals (Sweden)

    K. Ramachandran

    2012-02-01

    Full Text Available Spatial gradients of tomographic velocities are seldom used in interpretation of subsurface fault structures. This study shows that spatial velocity gradients can be used effectively in identifying subsurface discontinuities in the horizontal and vertical directions. Three-dimensional velocity models constructed through tomographic inversion of active source and/or earthquake traveltime data are generally built from an initial 1-D velocity model that varies only with depth. Regularized tomographic inversion algorithms impose constraints on the roughness of the model that help to stabilize the inversion process. Final velocity models obtained from regularized tomographic inversions have smooth three-dimensional structures that are required by the data. Final velocity models are usually analyzed and interpreted either as a perturbation velocity model or as an absolute velocity model. Compared to perturbation velocity model, absolute velocity models have an advantage of providing constraints on lithology. Both velocity models lack the ability to provide sharp constraints on subsurface faults. An interpretational approach utilizing spatial velocity gradients applied to northern Cascadia shows that subsurface faults that are not clearly interpretable from velocity model plots can be identified by sharp contrasts in velocity gradient plots. This interpretation resulted in inferring the locations of the Tacoma, Seattle, Southern Whidbey Island, and Darrington Devil's Mountain faults much more clearly. The Coast Range Boundary fault, previously hypothesized on the basis of sedimentological and tectonic observations, is inferred clearly from the gradient plots. Many of the fault locations imaged from gradient data correlate with earthquake hypocenters, indicating their seismogenic nature.

  13. X-ray tomographic apparatus

    International Nuclear Information System (INIS)

    Walters, R.G.

    1982-01-01

    An x-ray tomographic system consists of a radiation source such as gamma or x radiation which produces a fan-shaped beam. The fan is wide enough to encompass the patient circle. The system further includes means for rotating the radiation source about the patient for less than a full rotation, and detectors for detecting the radiation at positions that surround the patient by 180 0 plus the angle of the fan beam plus the angle between adjacent fan detectors. Attenuation data from the detectors is sorted into detector fans of attenuation data, then processed. The convolved data is back-projected into an image memory and displayed on a video monitor

  14. Antipsychotic treatment in schizophrenia: the role of computerized neuropsychological assessment.

    Science.gov (United States)

    Kertzman, Semion; Reznik, Ilya; Grinspan, Haim; Weizman, Abraham; Kotler, Moshe

    2008-01-01

    The present study analyzes the role of neurocognitive assessment instruments in the detection of the contribution of antipsychotic treatment to cognitive functioning. Recently, a panel of experts suggested six main domains (working memory; attention/vigilance; verbal/visual learning and memory; reasoning and problem solving; speed of processing) implicated in schizophrenia-related cognitive deficits, which serve as a theoretical base for creation of real-time computerized neurocognitive batteries. The high sensitivity of computerized neuropsychological testing is based on their ability to adopt the reaction time (RT) paradigm for the assessment of brain function in a real-time regime. This testing is highly relevant for the monitoring of the cognitive effects of antipsychotics. Computerized assessment assists in the identification of state- and trait-related cognitive impairments. The optimal real-time computerized neurocognitive battery should composite balance between broad and narrow coverage of cognitive domains relevant to the beneficial effects of antipsychotics and will enable better planning of treatment and rehabilitation programs.

  15. Temporal evaluation of computed tomographic scans at a Level 1 trauma department in a central South African hospital

    Directory of Open Access Journals (Sweden)

    Tony Tiemesmann

    2016-03-01

    Objectives: The present study analyses the authors’ institution’s multi-detector computed tomography (MDCT scan process as part of the imaging turnaround time of trauma patients. It is intended to serve as a baseline for the institution, to offer a comparison with institutions worldwide and to improve service delivery. Method: Relevant categorical data were collected from the trauma patient register and radiological information system (RIS from 01 February 2013 to 31 January 2014. A population of 1107 trauma patients who received a MDCT scan was included in the study. Temporal data were analysed as a continuum with reference to triage priority, time of day, type of CT scan and admission status. Results: The median trauma arrival to MDCT scan time (TTS and reporting turnaround time (RTAT were 69 (39–126 and 86 (53–146 minutes respectively. TTS was subdivided into the time when the patient arrived at trauma to the radiology referral (TTRef and submission of the radiology request, to the arrival at the MDCT (RefTS location. TTRef was statistically significantly longer than RefTS (p < 0.0001. RTAT was subdivided into the arrival at the MDCT to the start of the radiology report (STR and time taken to complete the report (RT. STR was statistically significantly longer than RT (p < 0.0001. Conclusion: The time to scan (TTS was comparable to, but unfortunately the report turnaround time (RTAT lagged behind, the findings of some first-world institutions.

  16. Directional fine structure in absorption of white x rays: A tomographic interpretation

    International Nuclear Information System (INIS)

    Korecki, P.; Szymonski, M.; Tolkiehn, M.; Novikov, D. V.; Materlik, G.

    2006-01-01

    We discuss directional fine structure in absorption of white x rays for tomographic imaging of crystal structure at the atomic level. The interference between a direct x-ray beam and the secondary waves coherently scattered inside a specimen modifies the total wave field at the position of the absorbing atoms. For a white x-ray beam, the wave field variations cancel out by energy integration for all directions, except for the near forward scattering components, coinciding with the incident beam. Therefore, two-dimensional patterns of the angular-dependent fine structure in absorption of white x rays can be interpreted as real-space projections of atomic structure. In this work, we present a theory describing the directional fine structure in white x-ray absorption and a tomographic approach for crystal structure retrieval developed on its basis. The tomographic algorithm is applied to the experimental x-ray absorption data recorded for GaP crystals

  17. Three-dimensional analysis and display of medical images

    International Nuclear Information System (INIS)

    Bajcsy, R.

    1985-01-01

    Until recently, the most common medical images were X-rays on film analyzed by an expert, ususally a radiologist, who used, in addition to his/her visual perceptual abilities, knowledge obtained through medical studies, and experience. Today, however, with the advent of various imaging techniques, X-ray computerized axial tomographs (CAT), positron emission tomographs (PET), ultrasound tomographs, nuclear magnetic resonance tomographs (NMR), just to mention a few, the images are generated by computers and displayed on computer-controlled devices; so it is appropriate to think about more quantitative and perhaps automated ways of data analysis. Furthermore, since the data are generated by computer, it is only natural to take advantage of the computer for analysis purposes. In addition, using the computer, one can analyze more data and relate different modalities from the same subject, such as, for example, comparing the CAT images with PET images from the same subject. In the next section (The PET Scanner) the authors shall only briefly mention with appropriate references the modeling of the positron emission tomographic scanner, since this imaging technique is not as widely described in the literature as the CAT scanner. The modeling of the interpreter is not going to be mentioned, since it is a topic that by itself deserves a full paper; see, for example, Pizer [1981]. The thrust of this chapter is on modeling the organs that are being imaged and the matching techniques between the model and the data. The image data is from CAT and PET scans. Although the authors believe that their techniques are applicable to any organ of the human body, the examples are only from the brain

  18. Characterization of tomographically faithful states in terms of their Wigner function

    International Nuclear Information System (INIS)

    D'Ariano, G M; Sacchi, M F

    2005-01-01

    A bipartite quantum state is tomographically faithful when it can be used as an input of a quantum operation acting on one of the two quantum systems, such that the joint output state carries complete information about the operation itself. Tomographically faithful states are a necessary ingredient for the tomography of quantum operations and for complete quantum calibration of measuring apparatuses. In this paper we provide a complete classification of such states for continuous variables in terms of the Wigner function of the state. For two-mode Gaussian states faithfulness simply resorts to correlation between the modes

  19. Bone densitometry with the computer tomograph

    International Nuclear Information System (INIS)

    Weiss, T.

    1978-01-01

    This work tests the usefulness of the EMI head scanner MARK I for a quantitative detection of ossary mineral content. Twenty-three concentration levels of a aqueous K 2 HPO 4 -solution were positioned by means of a special clamping device at the EMI-scanner and examined at tubevoltages of 100, 120 and 140 kV. This produces an almost linear dependence between CT-unit and sample concentration, whereby it shows that the measured special element densities of samples with the same densities vary in dependence with the voltage. The examination of an anotomical fore-arm preperate served as a statement for the reproductability of computer tomographic densitometry at non-moving biological objects. The test of reproductability of bone densitometry measurements under clinical conditions was made on the occation of the six time examinations of the right hand fore-arm bone of a young dummy. Furthermore densitometric examination were made at the fore-arm shelton of 40 long-time dialysis patients in the age levels between 17 and 67 years. The reproductability of the technique presented here is at least not better with the EMI-head-scanner MARK I used here. A change is possible by using the new whole body tomographs. (orig./MG) [de

  20. Computerized operation of the DIII-D neutral beams

    International Nuclear Information System (INIS)

    Glad, A.S.; Tooker, J.F.

    1986-01-01

    Operation of the DIII-D neutral beams utilizes computerized control to provide routine tokamak beam heating shots and an effective method for automatic ion source operation. Computerized control reduces operational complexity, thus providing consistent reliability and availability of beams and a significant reduction in the the costs of routine operation. The objectives in implementing computerized control for operation were: (1) to improve operator efficiency for controlling multiple beam lines and increasing beam availability through standard procedures, (2) to provide a simplified scheme that operators and coordinators can construct and maintain, and (3) to provide a single integrated mechanism for both tokamak operation and automatic source conditioning. The years of experience in operating neutral beams at Doublet III provided the data necessary to meet the objectives. The method for computerized control consisted of three integrated functions: (1) a structured command language was implemented to provide the mechanism for automatically sequencing beams, (2) a historical file was constructed from the operational parameters to characterize the ion source, and consists of data from approximately 100,000 beam shots, and (3) procedures were developed integrating the language to the historical file for normal operation and source conditioning. This paper describes the method for sequencing beams automatically, the structure of the historical data file, and the procedures which integrate the historical data with tokamak operation and automatic source conditioning

  1. Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols.

    Science.gov (United States)

    Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen

    2010-12-01

    The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.

  2. Development and Evaluation of a Confidence-Weighting Computerized Adaptive Testing

    Science.gov (United States)

    Yen, Yung-Chin; Ho, Rong-Guey; Chen, Li-Ju; Chou, Kun-Yi; Chen, Yan-Lin

    2010-01-01

    The purpose of this study was to examine whether the efficiency, precision, and validity of computerized adaptive testing (CAT) could be improved by assessing confidence differences in knowledge that examinees possessed. We proposed a novel polytomous CAT model called the confidence-weighting computerized adaptive testing (CWCAT), which combined a…

  3. Pain Perception: Computerized versus Traditional Local Anesthesia in Pediatric Patients.

    Science.gov (United States)

    Mittal, M; Kumar, A; Srivastava, D; Sharma, P; Sharma, S

    2015-01-01

    Local anesthetic injection is one of the most anxiety- provoking procedure for both children and adult patients in dentistry. A computerized system for slow delivery of local anesthetic has been developed as a possible solution to reduce the pain related to the local anesthetic injection. The present study was conducted to evaluate and compare pain perception rates in pediatric patients with computerized system and traditional methods, both objectively and subjectively. It was a randomized controlled study in one hundred children aged 8-12 years in healthy physical and mental state, assessed as being cooperative, requiring extraction of maxillary primary molars. Children were divided into two groups by random sampling - Group A received buccal and palatal infiltration injection using Wand, while Group B received buccal and palatal infiltration using traditional syringe. Visual Analog scale (VAS) was used for subjective evaluation of pain perception by patient. Sound, Eye, Motor (SEM) scale was used as an objective method where sound, eye and motor reactions of patient were observed and heart rate measurement using pulse oximeter was used as the physiological parameter for objective evaluation. Patients experienced significantly less pain of injection with the computerized method during palatal infiltration, while less pain was not statistically significant during buccal infiltration. Heart rate increased during both buccal and palatal infiltration in traditional and computerized local anesthesia, but difference between traditional and computerized method was not statistically significant. It was concluded that pain perception was significantly more during traditional palatal infiltration injection as compared to computerized palatal infiltration, while there was no difference in pain perception during buccal infiltration in both the groups.

  4. Computerized medical convocations

    International Nuclear Information System (INIS)

    Roche, Annie; Gilbert, Jean-Francois; Chiadot, Pierre; Vanzetto, Rene; Darnault, Jean

    1969-06-01

    Thanks to a close collaboration between the Medical and Social department and the Numerical Calculation Laboratory, a computerized convocation system has been implemented to reduce the administrative workload and to introduce more rigor in medical management, patient historical background and statistics. This work comprises: - a preliminary study of the data generating medical convocations and the related practical requirements; - the programming work according to these data; - the realisation of the mechano-graphical file covering the overall personnel [fr

  5. Tomographic evaluation of a dual-head positron emission tomography system

    International Nuclear Information System (INIS)

    Efthimiou, N; Maistros, S; Tripolitis, X; Panayiotakis, G; Samartzis, A; Loudos, G

    2011-01-01

    In this paper we present the performance evaluation results, in the planar and tomographic modes, of a low-cost positron emission tomography camera dedicated to small-animal imaging. The system consists of two pixelated Lu 2 SiO 5 crystals, two Hamamatsu H8500 position sensitive photomultiplier tubes, fast amplification electronics and an FPGA-USB-based read-out system. The parameters that have been studied are (i) saturation as a function of the head distance and photon acceptance angle, (ii) effect of the number of projections and half or complete head's rotation, (iii) spatial resolution as a function of the head distance, (iv) spatial resolution as a function of acceptance angle, (v) system's sensitivity as a function of these parameters and (vi) performance in small mice imaging. Image reconstruction has been carried out using open source software developed by our group (QSPECT), which is designed mainly for SPECT imaging. The results indicate that the system has a linear response for activities up to at least 2 MBq, which are typical in small-animal imaging. Best tomographic spatial resolution was measured to be ∼2 mm. The system has been found suitable for imaging of small mice both in the planar and tomographic modes

  6. Development of computerized stocktaking system in mine surveying for ore mineral volume calculation in covered storehouses

    Science.gov (United States)

    Valdman, V. V.; Gridnev, S. O.

    2017-10-01

    The article examines into the vital issues of measuring and calculating the raw stock volumes in covered storehouses at mining and processing plants. The authors bring out two state-of-the-art high-technology solutions: 1 - to use the ground-based laser scanning system (the method is reasonably accurate and dependable, but costly and time consuming; it also requires the stoppage of works in the storehouse); 2 - to use the fundamentally new computerized stocktaking system in mine surveying for the ore mineral volume calculation, based on the profile digital images. These images are obtained via vertical projection of the laser plane onto the surface of the stored raw materials.

  7. The computed tomographic appearances of cherubism

    International Nuclear Information System (INIS)

    Bianchi, S.D.; Boccardi, A.; Mela, F.; Romagnoli, R.

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression. (orig.)

  8. Computerized neurocognitive testing in the management of sport-related concussion: an update.

    Science.gov (United States)

    Resch, Jacob E; McCrea, Michael A; Cullum, C Munro

    2013-12-01

    Since the late nineties, computerized neurocognitive testing has become a central component of sport-related concussion (SRC) management at all levels of sport. In 2005, a review of the available evidence on the psychometric properties of four computerized neuropsychological test batteries concluded that the tests did not possess the necessary criteria to warrant clinical application. Since the publication of that review, several more computerized neurocognitive tests have entered the market place. The purpose of this review is to summarize the body of published studies on psychometric properties and clinical utility of computerized neurocognitive tests available for use in the assessment of SRC. A review of the literature from 2005 to 2013 was conducted to gather evidence of test-retest reliability and clinical validity of these instruments. Reviewed articles included both prospective and retrospective studies of primarily sport-based adult and pediatric samples. Summaries are provided regarding the available evidence of reliability and validity for the most commonly used computerized neurocognitive tests in sports settings.

  9. Computerized automated remote inspection system

    International Nuclear Information System (INIS)

    The automated inspection system utilizes a computer to control the location of the ultrasonic transducer, the actual inspection process, the display of the data, and the storage of the data on IBM magnetic tape. This automated inspection equipment provides two major advantages. First, it provides a cost savings, because of the reduced inspection time, made possible by the automation of the data acquisition, processing, and storage equipment. This reduced inspection time is also made possible by a computerized data evaluation aid which speeds data interpretation. In addition, the computer control of the transducer location drive allows the exact duplication of a previously located position or flaw. The second major advantage is that the use of automated inspection equipment also allows a higher-quality inspection, because of the automated data acquisition, processing, and storage. This storage of data, in accurate digital form on IBM magnetic tape, for example, facilitates retrieval for comparison with previous inspection data. The equipment provides a multiplicity of scan data which will provide statistical information on any questionable volume or flaw. An automatic alarm for location of all reportable flaws reduces the probability of operator error. This system has the ability to present data on a cathode ray tube as numerical information, a three-dimensional picture, or ''hard-copy'' sheet. One important advantage of this system is the ability to store large amounts of data in compact magnetic tape reels

  10. Computerized Interpretation of Dynamic Breast MRI

    National Research Council Canada - National Science Library

    Chen, Weijie; Giger, Maryellen Lissak

    2005-01-01

    ... and prognosis of breast cancer. The research involves investigation of automatic methods for image artifacts correction, tumor segmentation, and extraction of computerized features that help distinguish between benign and malignant lesions...

  11. Computerized access to materials data. A progress report

    International Nuclear Information System (INIS)

    Rumble, J. Jr.

    1985-01-01

    As the effort to build a comprehensive computerized materials data system grows, it becomes more obvious that the benefits will be far-reaching. During this workshop, the enthusiasm of the participants grew steadily until the questions became not''What,'' but ''When?''. The engineering community within the United States has banded together many times to advance progress in engineering capability. The computerized materials data system requires such an effort, and the rewards will be substantial. Chapter 3 identifies changes in the use of materials data in the Nuclear Power Industry. Chapter 4 describes the EPRI experience in building computerized materials databases. In Chapter 5, the National Materials Property Data Network is discussed. The next four chapters present summaries of the workshop discussions and its conclusions. Chapter 6 discusses the content of the proposed system, Chapter 7 its size and the data sources, and Chapter 8 the user interfaces and system capabilities. In Chapter 9, ways of making further progress are outlined

  12. Experience feedback of computerized controlled nuclear power plants

    International Nuclear Information System (INIS)

    Poizat, F.

    2004-01-01

    The N4 step of French PWR-type nuclear power plants is characterized by an instrumentation and control system entirely computerized (operation procedures including normal and accidental operation). Four power plants of this type (Chooz and Civaux sites) of 1450 MWe each were connected to the power grid between August 1996 and December 1999. The achievement of this program make it possible and necessary to carry out an experience feedback about the development, successes and difficulties encountered in order to draw out some lessons for future realizations. This is the aim of this article: 1 - usefulness and difficulties of such an experience feedback: evolution of instrumentation and control systems, necessary cautions; 2 - a successful computerized control: checking of systems operation, advantages, expectations; 3 - efficiency of computerized systems: demonstration of operation safety, profitability; 4 - conclusions and interrogations: system approach instead of 'micro-software' approach, commercial or 'made to measure' products, contract agreement with a supplier, when and how upgrading. (J.S.)

  13. [X-ray computed tomographic abnormalities in schizophrenia. Trial of relationship with clinical data].

    Science.gov (United States)

    D'Amato, T; Rochet, T; Dalery, J; Chauchat, J H; Terra, J L; Arteaga, C; Marie-Cardine, M

    1992-01-01

    Computerized tomography (CT-scan) studies in schizophrenia revealed that some patients have neuromorphological abnormalities. The structural changes consist mainly in lateral and third ventricle enlargement, and in cortical atrophy. The present study evaluates these three changes in 42 schizophrenics aged 18 to 50, compared to 24 healthy controls. Diagnosis were established from information gathered by personal interview with the SADS-LA. Clinical sub-types were evaluated according to the DSM III-R criteria. Moreover, detailed symptoms were rated according to the Positive And Negative Syndrome Scale (PANSS). CT scans were recorded in floppy disks and blindly analyzed. Schizophrenics shown significant higher mean size of lateral and third ventricles, and higher mean anterior cortical atrophy than healthy subjects. Significant differences were also found between subtypes, with more marked abnormalities in the disorganized group. The relationship between brain abnormalities and clinical symptoms recorded with the PANSS, were analysed using Pearson correlates. Positive correlations concerned mainly negative symptoms like blunted affect, emotional withdrawal, difficulties in abstract thinking, passive apathetic social withdrawal and lack of spontaneity of conversation. Positive correlations are also observed with some symptoms classified with the PANSS in the General Psychopathology scale such as mannerism and disorientation. Negative correlation concerned most of PANSS positive symptoms.

  14. Computed tomographic findings of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Chung Kie [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1982-09-15

    It is well known that CT is very useful in the evaluation of hepatocellular carcinoma. The computed tomographic findings of 56 patients diagnosed as hepatocellular carcinoma were reviewed and analyzed. The results were as follows: 1. The male to female ratio was 3 : 1 and the age ranged from 31 to 73 years with average age of 54 years. 2. Alpha-fetoprotein was positive in 19 out of 38 cases (50%). HBsAg was positive in 8 out of 33 cases (24%). 3. All lesions were seen as areas of low density except 1 case (0%) of isodensity, and 40 cases (72%) appeared to be solitary while 15 (26%) were multifocal. The low density was homogenous in 13 cases (24%) and inhomogenous in 42 cases (76%), and 18 cases out of 42 cases inhomogenous low density showed peripheal and/or central nodular enhancement. The additional findings were contour changes in 37 cases (66%), metastasis in 35 cases (63%), splenomegaly in 23 cases (42%) and ascities in 22 cases (39%). 4. In postcontrast scans, 41 cases (80%) out of 51 cases showed the change of density after contrast infusion. The presence and extent of tumors were better seen after contrast infusion in 30 cases (59%), better seen before contrast infusion in 11 cases (21%) and no significant difference before and after contrast infusion in 10 cases (20%). 5. The sites of involved lobe were right lobe in 38 cases (68%), left lobe in 5 cases (9%) and both lobes in 13 cases (23%). 6. 35 cases (63%) showed evidence of metastasis to regional lymph nodes, organ or tissues.

  15. Computed tomographic findings of cerebral paragonimiasis

    International Nuclear Information System (INIS)

    Bae, Weon Tae; Jung, Min Ki; Kang, Heoung Keun; Chung, Hyon De

    1988-01-01

    Authors analyzed the computed tomographic (CT) findings of 19 cases pathologically and clinically proven cerebral paragonimiasis that were performed at Chonnam University Hospital from April 1983 through March 1987. The results were as follows: 1. Male to female ratio was 15:4 and the most prevalent age group was 3rd decade (7 cases). The common symptoms were epileptic seizure (16 cases) and headache (12 cases). 2. The multiplicity of cerebral paragonimiasis was 7 of 19 cases and the distributions of lesion were occipital (11 cases), temporal (6 cases), frontal (5 cases) and parietal (5 cases) lobe. 3. The calcification on CT scan were single (7 cases) or multiple (7 cases) and the shape of calcification were nodular (10 cases), soap babble of ring (8 cases), and stippled (6 cases). The pattern of contrast enhancement were ring (5 cases) or nodular (1 case), and along the basal cistern (1 case with arachnoiditis). 4. 12 out of 13 cases, had long clinical symptoms over 3 years with calcifications, could be analyzed according to Valentine's vascular territory; 6 cases in PCA territory, 3 in MCA and 3 in ACA. 5. CT findings were noted according to the duration of symptoms; 5 cases, had symptoms less than 1 year, showed abscess (5 cases) and arachnoiditis (1 case) with brain edema, mass effect, hydrocephalus and contrast enhancement but no calcification in all. One case, had symptom of 1 year and 2 months, showed partially calcified granulomatous lesion with perifocal edema and contrast enhancement, 13 cases, had symptoms over 3 years, showed multiple calcification with brain atrophy (10 cases), but no contrast enhancement in all cases.

  16. Self-masking noise subtraction (SMNS) in digital X-ray tomosynthesis for the improvement of tomographic image quality

    International Nuclear Information System (INIS)

    Oh, J.E.; Cho, H.S.; Choi, S.I.; Park, Y.O.; Lee, M.S.; Cho, H.M.; Yang, Y.J.; Je, U.K.; Woo, T.H.; Lee, H.K.

    2011-01-01

    In this paper, we proposed a simple and effective reconstruction algorithm, the so-called self-masking noise subtraction (SMNS), in digital X-ray tomosynthesis to reduce the tomographic blur that is inherent in the conventional tomosynthesis based upon the shift-and-add (SAA) method. Using the SAA and the SMNS algorithms, we investigated the influence of tomographic parameters such as tomographic angle (θ) and angle step (Δθ) on the image quality, measuring the signal-difference-to-noise ratio (SDNR). Our simulation results show that the proposed algorithm seems to be efficient in reducing the tomographic blur and, thus, improving image sharpness. We expect the simulation results to be useful for the optimal design of a digital X-ray tomosynthesis system for our ongoing application of nondestructive testing (NDT).

  17. 3D scanning particle tracking velocimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hoyer, Klaus; Holzner, Markus; Guala, Michele; Liberzon, Alexander; Kinzelbach, Wolfgang [Swiss Federal Institut of Technology Zurich, Institut fuer Hydromechanik und Wasserwirtschaft, Zuerich (Switzerland); Luethi, Beat [Risoe National Laboratory, Roskilde (Denmark)

    2005-11-01

    In this article, we present an experimental setup and data processing schemes for 3D scanning particle tracking velocimetry (SPTV), which expands on the classical 3D particle tracking velocimetry (PTV) through changes in the illumination, image acquisition and analysis. 3D PTV is a flexible flow measurement technique based on the processing of stereoscopic images of flow tracer particles. The technique allows obtaining Lagrangian flow information directly from measured 3D trajectories of individual particles. While for a classical PTV the entire region of interest is simultaneously illuminated and recorded, in SPTV the flow field is recorded by sequential tomographic high-speed imaging of the region of interest. The advantage of the presented method is a considerable increase in maximum feasible seeding density. Results are shown for an experiment in homogenous turbulence and compared with PTV. SPTV yielded an average 3,500 tracked particles per time step, which implies a significant enhancement of the spatial resolution for Lagrangian flow measurements. (orig.)

  18. Diversity in computerized reactor protection systems

    International Nuclear Information System (INIS)

    Fischer, H.D.; Piel, L.

    1999-01-01

    Based on engineering judgement, the most important measures to increase the independency of redundant trains of a computerized safety instrumentation and control system (I and C) in a nuclear power plant are evaluated with respect to practical applications. This paper will contribute to an objective discussion on the necessary and justifiable arrangement of diversity in a computerized safety I and C system. Important conclusions are: - (i) diverse equipment may be used to control dependent failures only if measures necessary for designing, licensing, and operating a computerized safety I and C system homogeneous in equipment are neither technically nor economically feasible; - (ii) the considerable large operating experience in France with a non-diverse equipment digital reactor protection system does not call for equipment diversity. Although there are no generally accepted methods, the licensing authority is still required to take into account dependent failures in a probabilistic safety analysis; - (ii) the frequency of postulated initiating events implies which I and C functionality should be implemented on diverse equipment. Using non-safety I and C equipment in addition to safety I and C equipment is attractive because its necessary unavailability to control an initiating event in teamwork with the safety I and C equipment is estimated to range from 0.01 to 0.1. This can be achieved by operational experience

  19. DG TOMO: A new method for tomographic reconstruction

    International Nuclear Information System (INIS)

    Freitas, D. de; Feschet, F.; Cachin, F.; Geissler, B.; Bapt, A.; Karidioula, I.; Martin, C.; Kelly, A.; Mestas, D.; Gerard, Y.; Reveilles, J.P.; Maublant, J.

    2006-01-01

    Aim: FBP and OSEM are the most popular tomographic reconstruction methods in scintigraphy. FBP is a simple method but artifacts of reconstruction are generated which corrections induce degradation of the spatial resolution. OSEM takes account of statistical fluctuations but noise strongly increases after a certain number of iterations. We compare a new method of tomographic reconstruction based on discrete geometry (DG TOMO) to FBP and OSEM. Materials and methods: Acquisitions were performed on a three-head gamma-camera (Philips) with a NEMA Phantom containing six spheres of sizes from 10 to 37 mm inner diameter, filled with around 325 MBq/l of technetium-99 m. The spheres were positioned in water containing 3 MBq/l of technetium-99 m. Acquisitions were realized during a 180 o -rotation around the phantom by 25-s steps. DG TOMO has been developed in our laboratory in order to minimize the number of projections at acquisition. Two tomographic reconstructions utilizing 32 and 16 projections with FBP, OSEM and DG TOMO were performed and transverse slices were compared. Results: FBP with 32 projections detects only the activity in the three largest spheres (diameter ≥22 mm). With 16 projections, the star effect is predominant and the contrast of the third sphere is very low. OSEM with 32 projections provides a better image but the three smallest spheres (diameter ≤17 mm) are difficult to distinguish. With 16 projections, the three smaller spheres are not detectable. The results of DG TOMO are similar to OSEM. Conclusion: Since the parameters of DG TOMO can be further optimized, this method appears as a promising alternative for tomoscintigraphy reconstruction

  20. Assessment of hybrid rotation-translation scan schemes for in vivo animal SPECT imaging

    International Nuclear Information System (INIS)

    Xia Yan; Liu Yaqiang; Wang Shi; Ma Tianyu; Yao Rutao; Deng Xiao

    2013-01-01

    To perform in vivo animal single photon emission computed tomography imaging on a stationary detector gantry, we introduced a hybrid rotation-translation (HRT) tomographic scan, a combination of translational and limited angle rotational movements of the image object, to minimize gravity-induced animal motion. To quantitatively assess the performance of ten HRT scan schemes and the conventional rotation-only scan scheme, two simulated phantoms were first scanned with each scheme to derive the corresponding image resolution (IR) in the image field of view. The IR results of all the scan schemes were visually assessed and compared with corresponding outputs of four scan scheme evaluation indices, i.e. sampling completeness (SC), sensitivity (S), conventional system resolution (SR), and a newly devised directional spatial resolution (DR) that measures the resolution in any specified orientation. A representative HRT scheme was tested with an experimental phantom study. Eight of the ten HRT scan schemes evaluated achieved a superior performance compared to two other HRT schemes and the rotation-only scheme in terms of phantom image resolution. The same eight HRT scan schemes also achieved equivalent or better performance in terms of the four quantitative indices than the conventional rotation-only scheme. As compared to the conventional index SR, the new index DR appears to be a more relevant indicator of system resolution performance. The experimental phantom image obtained from the selected HRT scheme was satisfactory. We conclude that it is feasible to perform in vivo animal imaging with a HRT scan scheme and SC and DR are useful predictors for quantitatively assessing the performance of a scan scheme. (paper)