WorldWideScience

Sample records for computerized test system

  1. Computerized adaptive testing item selection in computerized adaptive learning systems

    NARCIS (Netherlands)

    Eggen, Theodorus Johannes Hendrikus Maria; Eggen, T.J.H.M.; Veldkamp, B.P.

    2012-01-01

    Item selection methods traditionally developed for computerized adaptive testing (CAT) are explored for their usefulness in item-based computerized adaptive learning (CAL) systems. While in CAT Fisher information-based selection is optimal, for recovering learning populations in CAL systems item

  2. Computerized adaptive testing in computer assisted learning?

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; Eggen, Theodorus Johannes Hendrikus Maria; De Wannemacker, Stefan; Clarebout, Geraldine; De Causmaecker, Patrick

    2011-01-01

    A major goal in computerized learning systems is to optimize learning, while in computerized adaptive tests (CAT) efficient measurement of the proficiency of students is the main focus. There seems to be a common interest to integrate computerized adaptive item selection in learning systems and

  3. Some procedures for computerized ability testing

    NARCIS (Netherlands)

    van der Linden, Willem J.; Zwarts, Michel A.

    1989-01-01

    For computerized test systems to be operational, the use of item response theory is a prerequisite. As opposed to classical test theory, in item response models the abilities of the examinees and the properties of the items are parameterized separately. Hence, when measuring the abilities of

  4. Microcomputer Network for Computerized Adaptive Testing (CAT)

    Science.gov (United States)

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  5. Computerized ECT data analysis system

    International Nuclear Information System (INIS)

    Miyake, Y.; Fukui, S.; Iwahashi, Y.; Matsumoto, M.; Koyama, K.

    1988-01-01

    For the analytical method of the eddy current testing (ECT) of steam generator tubes in nuclear power plants, the authors have developed the computerized ECT data analysis system using a large-scale computer with a high-resolution color graphic display. This system can store acquired ECT data up to 15 steam generators, and ECT data can be analyzed immediately on the monitor in dialogue communication with a computer. Analyzed results of ECT data are stored and registered in the data base. This system enables an analyst to perform sorting and collecting of data under various conditions and obtain the results automatically, and also to make a plan of tube repair works. This system has completed the test run, and has been used for data analysis at the annual inspection of domestic plants. This paper describes an outline, features and examples of the computerized eddy current data analysis system for steam generator tubes in PWR nuclear power plants

  6. Computerized Classification Testing with the Rasch Model

    Science.gov (United States)

    Eggen, Theo J. H. M.

    2011-01-01

    If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…

  7. Computerized tomography used in non-destructive testing of welded pipes

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, M; Rizescu, C; Georgescu, G; Marinescu, A; Chitescu, P; Sava, T; Neagu, M; Avram, D [Institute of Research and Design for Electrical Engineering, ICPE - Electrostatica Splaiul Unirii 313, Sect. 3, R-74204 Bucharest (Romania)

    1997-12-31

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using {gamma}-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or {gamma}-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: (1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., (2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs.

  8. Computerized tomography used in non-destructive testing of welded pipes

    International Nuclear Information System (INIS)

    Iovea, M.; Rizescu, C.; Georgescu, G.; Marinescu, A.; Chitescu, P.; Sava, T.; Neagu, M.; Avram, D.

    1996-01-01

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using γ-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or γ-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: 1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., 2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs

  9. Development of a testing methodology for computerized procedure system based on JUnit framework and MFM

    International Nuclear Information System (INIS)

    Qin, Wei

    2004-02-01

    Paper Based Procedure (PBP) and Computerized Procedure System (CPS) are studied to demonstrate that it is necessary to develop CPS in Nuclear Power Plant (NPP) Instrumentation and Control (I and C) system. Computerized procedure system is actually a software system. All the desired and undesired properties of a software system can be described and evaluated as software qualities. Generally, software qualities can be categorized into product quality and process quality. In order to achieve product quality, the process quality of a software system should also be considered and achieved. Characteristics of CPS will be described to analyse the product and process of an example CPS: ImPRO. At the same time, several main product and process issues will be analysed from Verification and Validation (V and V) point of view. It is concluded and suggested that V and V activities can also be regarded as a software development process, this point of view then is applied to the V and V activities of ImPRO as a systematic approach of testing of ImPRO. To support and realize this approach, suitable testing technologies and testing strategies are suggested based on JUnit framework and Multi-level Flow Modeling (MFM)

  10. COMPRESS - a computerized reactor safety system

    International Nuclear Information System (INIS)

    Vegh, E.

    1986-01-01

    The computerized reactor safety system, called COMPRESS, provides the following services: scram initiation; safety interlockings; event recording. The paper describes the architecture of the system and deals with reliability problems. A self-testing unit checks permanently the correct operation of the independent decision units. Moreover the decision units are tested by short pulses whether they can initiate a scram. The self-testing is described in detail

  11. Implementation of computerized add-on testing for hospitalized patients in a large academic medical center.

    Science.gov (United States)

    Kim, Ji Yeon; Kamis, Irina K; Singh, Balaji; Batra, Shalini; Dixon, Roberta H; Dighe, Anand S

    2011-05-01

    Physician requests for additional testing on an existing laboratory specimen (add-ons) are resource intensive and generally require a phone call to the laboratory. Verbal orders such as these have been noted to be associated with errors in accuracy. The aim of this study was to compare a novel computerized system for add-on requests to the prior verbal system. We compare the computerized add-on request system to the verbal system with respect to order completeness and workflow. We demonstrate that the computerized add-on system resulted in the complete in-laboratory documentation of the add-on request 100% of the time, compared to 58% with the verbal add-on system. In addition, we show that documentation of a verbal add-on request in the electronic medical record (EMR) occurred for 4% of requests, while in the computerized system EMR documentation occurred 100% of the time. We further demonstrate that the computerized add-on request process was well accepted by providers and did not significantly change the test mix of the add-on requests. In computerized physician order entry (CPOE) implementations, add-on order functionality should be considered so these orders are documented in the EMR.

  12. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    Science.gov (United States)

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  13. Computerized adaptive testing--ready for ambulatory monitoring?

    DEFF Research Database (Denmark)

    Rose, Matthias; Bjørner, Jakob; Fischer, Felix

    2012-01-01

    Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted.......Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted....

  14. Lessons learned from implementation of a computerized application for pending tests at hospital discharge.

    Science.gov (United States)

    Dalal, Anuj K; Poon, Eric G; Karson, Andrew S; Gandhi, Tejal K; Roy, Christopher L

    2011-01-01

    Patients are often discharged from the hospital before test results are finalized. Awareness of these results is poor and therefore an important patient safety concern. Few computerized systems have been deployed at care transitions to address this problem. We describe an attempt to implement a computerized application to help inpatient physicians manage these test results. We modified an ambulatory electronic medical record (EMR)-based results management application to track pending tests at hospital discharge (Hospitalist Results Manager, HRM). We trained inpatient physicians at 2 academic medical centers to track these tests using this application. We surveyed inpatient physicians regarding usage of and satisfaction with the application, barriers to use, and the characteristics of an ideal system to track pending tests at discharge. Of 29 survey respondents, 14 (48%) reported never using HRM, and 13 (45%) used it 1 to 2 times per week. A total of 23 (79%) reported barriers prohibiting use, including being inundated with clinically "irrelevant" results, not having sufficient time, and a lack of integration of post-discharge test result management into usual workflow. Twenty-one (72%) wanted to receive notification of abnormal and clinician-designated pending test results. Twenty-seven physicians (93%) agreed that an ideally designed computerized application would be valuable for managing pending tests at discharge. Although inpatient physicians would highly value a computerized application to manage pending tests at discharge, the characteristics of an ideal system are unclear and there are important barriers prohibiting adoption and optimal usage of such systems. We outline suggestions for future electronic systems to manage pending tests at discharge. Copyright © 2010 Society of Hospital Medicine.

  15. Computerized Tests. New practical and ethical challenges for Psychological Assessment

    Directory of Open Access Journals (Sweden)

    Gabriela Susana Lozzia

    2013-08-01

    Full Text Available The purpose of this study is to bring the readers in our field of knowledge closer to the new problems and solutions resulting from the application of computer systems to Psychological Assessment. Therefore, this work puts forward a suitable implementation of Computer-based and Internet-delivered Testing, includes a description of the new technologies that can be applied to Psychological Assessment: administration of traditional paper-and-pencil tests through computers, elaboration of automated reports, computerized adaptive tests, automated test construction and automatic generation of items, as well as the specific guidelines and regulations governing the development of each of these areas. This study provides an outline of the current issues connected with the appropriate use of Computerized Tests by way of conclusion and finally encourages psychologists to keep debating and reflecting on these topics.

  16. Using mobile and web-based computerized tests to evaluate university students

    NARCIS (Netherlands)

    Romero, C.; Ventura, S.; De Bra, P.M.E.

    2009-01-01

    Mobile learning and testing is emerging as a potential educational environment. In this article we evaluate the use of mobile devices for testing as compared to web-based assessment systems. We also describe an authoring tool to develop adaptable and adaptive computerized tests that can be executed

  17. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  18. Computerized system for measuring cerebral metabolism

    International Nuclear Information System (INIS)

    McGlone, J.S.; Hibbard, L.S.; Hawkins, R.A.; Kasturi, R.

    1987-01-01

    A computerized stereotactic measurement system for evaluating rat brain metabolism was developed to utilize the large amount of data generated by quantitative autoradiography. Conventional methods of measurement only analyze a small percent of these data because these methods are limited by instrument design and the subjectiveness of the investigator. However, a computerized system allows digital images to be analyzed by placing data at their appropriate three-dimensional stereotactic coordinates. The system automatically registers experimental data to a standard three-dimensional image using alignment, scaling, and matching operations. Metabolic activity in different neuronal structures is then measured by generating digital masks and superimposing them on to experimental data. Several experimental data sets were evaluated and it was noticed that the structures measured by the computerized system, had in general, lower metabolic activity than manual measurements had indicated. This was expected because the computerized system measured the structure over its volume while the manual readings were taken from the most active metabolic area of a particular structure

  19. Assessment of Minimal HE (with emphasis on computerized psychometric tests)

    Science.gov (United States)

    Kappus, Matthew R; Bajaj, Jasmohan S

    2012-01-01

    Synopsis Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life and driving accidents. The detection of MHE requires specialized testing since it cannot by definition, be diagnosed on standard clinical examination. Psychometric (paper-pencil or computerized or a combination) and neuro-physiological techniques are often used to test for MHE. Paper-pencil psychometric batteries like the Psychometric Hepatic Encephalopathy Score (PHES) have been validated in several countries but do not have US normative values. Computerized tests such as the inhibitory control test (ICT), cognitive drug research system and Scan test have proven useful to diagnose MHE and predict outcomes. The specificity and sensitivity of these tests are similar to the recommended gold standards. Neuro-physiological tests such as the EEG and its interpretations, evoked potentials and Critical Flicker Frequency (CFF) also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike and the testing strategies depend on the normative data available, patient comfort and local expertise. PMID:22321464

  20. Individual Differences in Computerized Adaptive Testing.

    Science.gov (United States)

    Kim, JinGyu

    Research on the major computerized adaptive testing (CAT) strategies is reviewed, and some findings are reported that examine effects of examinee demographic and psychological characteristics on CAT strategies. In fixed branching strategies, all examinees respond to a common routing test, the score of which is used to assign examinees to a…

  1. Computerized neurocognitive testing in the management of sport-related concussion: an update.

    Science.gov (United States)

    Resch, Jacob E; McCrea, Michael A; Cullum, C Munro

    2013-12-01

    Since the late nineties, computerized neurocognitive testing has become a central component of sport-related concussion (SRC) management at all levels of sport. In 2005, a review of the available evidence on the psychometric properties of four computerized neuropsychological test batteries concluded that the tests did not possess the necessary criteria to warrant clinical application. Since the publication of that review, several more computerized neurocognitive tests have entered the market place. The purpose of this review is to summarize the body of published studies on psychometric properties and clinical utility of computerized neurocognitive tests available for use in the assessment of SRC. A review of the literature from 2005 to 2013 was conducted to gather evidence of test-retest reliability and clinical validity of these instruments. Reviewed articles included both prospective and retrospective studies of primarily sport-based adult and pediatric samples. Summaries are provided regarding the available evidence of reliability and validity for the most commonly used computerized neurocognitive tests in sports settings.

  2. Development and Evaluation of a Confidence-Weighting Computerized Adaptive Testing

    Science.gov (United States)

    Yen, Yung-Chin; Ho, Rong-Guey; Chen, Li-Ju; Chou, Kun-Yi; Chen, Yan-Lin

    2010-01-01

    The purpose of this study was to examine whether the efficiency, precision, and validity of computerized adaptive testing (CAT) could be improved by assessing confidence differences in knowledge that examinees possessed. We proposed a novel polytomous CAT model called the confidence-weighting computerized adaptive testing (CWCAT), which combined a…

  3. Computerized tomographic in non-destructive testing

    International Nuclear Information System (INIS)

    Lopes, R.T.

    1988-01-01

    The process of computerized tomography has been developed for medical imaging purposes using tomographs with X-ray, and little attention has been given to others possibles applications of technique, because of its cost. As an alternative for the problem, we constructed a Tomographic System (STAC-1), using gamma-rays, for nonmedical applications. In this work we summarize the basic theory of reconstructing images using computerized tomography and we describe the considerations leading to the development of the experimental system. The method of reconstruction image implanted in the system is the filtered backprojection or convolution, with a digital filters system to carried on a pre-filtering in the projections. The experimental system is described, with details of control and the data processing. An alternative and a complementary system, using film as a detector is shown in preliminary form . This thesis discuss and shows the theorical and practical aspects, considered in the construction of the STAC-1, and also its limitations and apllications [pt

  4. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  5. Procedures for Selecting Items for Computerized Adaptive Tests.

    Science.gov (United States)

    Kingsbury, G. Gage; Zara, Anthony R.

    1989-01-01

    Several classical approaches and alternative approaches to item selection for computerized adaptive testing (CAT) are reviewed and compared. The study also describes procedures for constrained CAT that may be added to classical item selection approaches to allow them to be used for applied testing. (TJH)

  6. A COMPUTERIZED OPERATOR SUPPORT SYSTEM PROTOTYPE

    Energy Technology Data Exchange (ETDEWEB)

    Thomas A. Ulrich; Roger Lew; Ronald L. Boring; Ken Thomas

    2015-03-01

    A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. A prototype COSS was developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, piping and instrumentation diagram system representations, and a recommender module for mitigation actions. The initial version of the prototype is now operational at the Idaho National Laboratory using the Human System Simulation Laboratory.

  7. Sequential Computerized Mastery Tests--Three Simulation Studies

    Science.gov (United States)

    Wiberg, Marie

    2006-01-01

    A simulation study of a sequential computerized mastery test is carried out with items modeled with the 3 parameter logistic item response theory model. The examinees' responses are either identically distributed, not identically distributed, or not identically distributed together with estimation errors in the item characteristics. The…

  8. The Computerized Laboratory Notebook concept for genetic toxicology experimentation and testing.

    Science.gov (United States)

    Strauss, G H; Stanford, W L; Berkowitz, S J

    1989-03-01

    We describe a microcomputer system utilizing the Computerized Laboratory Notebook (CLN) concept developed in our laboratory for the purpose of automating the Battery of Leukocyte Tests (BLT). The BLT was designed to evaluate blood specimens for toxic, immunotoxic, and genotoxic effects after in vivo exposure to putative mutagens. A system was developed with the advantages of low cost, limited spatial requirements, ease of use for personnel inexperienced with computers, and applicability to specific testing yet flexibility for experimentation. This system eliminates cumbersome record keeping and repetitive analysis inherent in genetic toxicology bioassays. Statistical analysis of the vast quantity of data produced by the BLT would not be feasible without a central database. Our central database is maintained by an integrated package which we have adapted to develop the CLN. The clonal assay of lymphocyte mutagenesis (CALM) section of the CLN is demonstrated. PC-Slaves expand the microcomputer to multiple workstations so that our computerized notebook can be used next to a hood while other work is done in an office and instrument room simultaneously. Communication with peripheral instruments is an indispensable part of many laboratory operations, and we present a representative program, written to acquire and analyze CALM data, for communicating with both a liquid scintillation counter and an ELISA plate reader. In conclusion we discuss how our computer system could easily be adapted to the needs of other laboratories.

  9. A comparison of computerized adaptive testing and fixed-length short forms for the Prosthetic Limb Users Survey of Mobility (PLUS-MTM).

    Science.gov (United States)

    Amtmann, Dagmar; Bamer, Alyssa M; Kim, Jiseon; Bocell, Fraser; Chung, Hyewon; Park, Ryoungsun; Salem, Rana; Hafner, Brian J

    2017-09-01

    New health status instruments can be administered by computerized adaptive test or short forms. The Prosthetic Limb Users Survey of Mobility (PLUS-M TM ) is a self-report measure of mobility for prosthesis users with lower limb loss. This study used the PLUS-M to examine advantages and disadvantages of computerized adaptive test and short forms. To compare scores obtained from computerized adaptive test to scores obtained from fixed-length short forms (7-item and 12-item) in order to provide guidance to researchers and clinicians on how to select the best form of administration for different uses. Cross-sectional, observational study. Individuals with lower limb loss completed the PLUS-M by computerized adaptive test and short forms. Administration time, correlations between the scores, and standard errors were compared. Scores and standard errors from the computerized adaptive test, 7-item short form, and 12-item short form were highly correlated and all forms of administration were efficient. Computerized adaptive test required less time to administer than either paper or electronic short forms; however, time savings were minimal compared to the 7-item short form. Results indicate that the PLUS-M computerized adaptive test is most efficient, and differences in scores between administration methods are minimal. The main advantage of the computerized adaptive test was more reliable scores at higher levels of mobility compared to short forms. Clinical relevance Health-related item banks, like the Prosthetic Limb Users Survey of Mobility (PLUS-M TM ), can be administered by computerized adaptive testing (CAT) or as fixed-length short forms (SFs). Results of this study will help clinicians and researchers decide whether they should invest in a CAT administration system or whether SFs are more appropriate.

  10. Computerized Adaptive Test (CAT) Applications and Item Response Theory Models for Polytomous Items

    Science.gov (United States)

    Aybek, Eren Can; Demirtasli, R. Nukhet

    2017-01-01

    This article aims to provide a theoretical framework for computerized adaptive tests (CAT) and item response theory models for polytomous items. Besides that, it aims to introduce the simulation and live CAT software to the related researchers. Computerized adaptive test algorithm, assumptions of item response theory models, nominal response…

  11. Computerized procedures system

    Science.gov (United States)

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  12. The Language Research Center's Computerized Test System for environmental enrichment and psychological assessment

    Science.gov (United States)

    Washburn, D. A.; Rumbaugh, D. M.; Richardson, W. K.

    1992-01-01

    In the spring of 1987, we undertook to provide environmental enrichment to nonhuman primate subjects in ways that would complement and even contribute to the bio-behaviorial science that justified the monkeys' captivity. Of course, the psychological well-being of captive primates--and indeed all research species-- has been an area of intense research activity since the 1985 amendment of the Animal Welfare Act. This mandate for researchers to ensure the psychological, as well as physical, fitness of experimental animals catalyzed the humane and scientific interests of the research community. The contemporary literature is replete with proposed means both of assaying and of providing enrichment and well-being. Notwithstanding, consensus on either assessment or intervention has yet to be reached. The paradigm we employed was modelled after successful efforts with chimpanzees. An automated test system was constructed in which subjects responded to computer tasks by manipulating a joystick. The tasks, interactive game-like versions of many of the classic testing paradigms of cognitive and comparative psychology, permitted the controlled presentation of stimuli and demands without the required presence of a human experimenter. Despite significant barriers to the success, rhesus monkeys (Macaca mulatta) and a variety of other primate species (including, of course, humans) have mastered the skills necessary for testing in this paradigm. Previous experiments have illustrated the utility of the test system for addressing questions of learning, memory, attention, perception, and motivation. Additional data have been reported to support the contention that the Language Research Center's Computerized Test System (LRC-CTS) serves its other raison d'etre--providing environmental enrichment and assessing psychological well-being. This paper is designed to augment previous descriptions of the technology and the paradigm for scientists and caretakers interested in environmental

  13. Termination Criteria for Computerized Classification Testing

    Directory of Open Access Journals (Sweden)

    Nathan A. Thompson

    2011-02-01

    Full Text Available Computerized classification testing (CCT is an approach to designing tests with intelligent algorithms, similar to adaptive testing, but specifically designed for the purpose of classifying examinees into categories such as - pass- and - fail.- Like adaptive testing for point estimation of ability, the key component is the termination criterion, namely the algorithm that decides whether to classify the examinee and end the test or to continue and administer another item. This paper applies a newly suggested termination criterion, the generalized likelihood ratio (GLR, to CCT. It also explores the role of the indifference region in the specification of likelihood-ratio based termination criteria, comparing the GLR to the sequential probability ratio test. Results from simulation studies suggest that the GLR is always at least as efficient as existing methods.

  14. A Feedback Control Strategy for Enhancing Item Selection Efficiency in Computerized Adaptive Testing

    Science.gov (United States)

    Weissman, Alexander

    2006-01-01

    A computerized adaptive test (CAT) may be modeled as a closed-loop system, where item selection is influenced by trait level ([theta]) estimation and vice versa. When discrepancies exist between an examinee's estimated and true [theta] levels, nonoptimal item selection is a likely result. Nevertheless, examinee response behavior consistent with…

  15. Psychometrics behind Computerized Adaptive Testing.

    Science.gov (United States)

    Chang, Hua-Hua

    2015-03-01

    The paper provides a survey of 18 years' progress that my colleagues, students (both former and current) and I made in a prominent research area in Psychometrics-Computerized Adaptive Testing (CAT). We start with a historical review of the establishment of a large sample foundation for CAT. It is worth noting that the asymptotic results were derived under the framework of Martingale Theory, a very theoretical perspective of Probability Theory, which may seem unrelated to educational and psychological testing. In addition, we address a number of issues that emerged from large scale implementation and show that how theoretical works can be helpful to solve the problems. Finally, we propose that CAT technology can be very useful to support individualized instruction on a mass scale. We show that even paper and pencil based tests can be made adaptive to support classroom teaching.

  16. A computerized legal information management system | Ohiagu ...

    African Journals Online (AJOL)

    A computerized legal information management system. ... process through the filling system using the survey research methodology. ... A framework for the design and implementation of a legal information management system was presented.

  17. Diversity in computerized reactor protection systems

    International Nuclear Information System (INIS)

    Fischer, H.D.; Piel, L.

    1999-01-01

    Based on engineering judgement, the most important measures to increase the independency of redundant trains of a computerized safety instrumentation and control system (I and C) in a nuclear power plant are evaluated with respect to practical applications. This paper will contribute to an objective discussion on the necessary and justifiable arrangement of diversity in a computerized safety I and C system. Important conclusions are: - (i) diverse equipment may be used to control dependent failures only if measures necessary for designing, licensing, and operating a computerized safety I and C system homogeneous in equipment are neither technically nor economically feasible; - (ii) the considerable large operating experience in France with a non-diverse equipment digital reactor protection system does not call for equipment diversity. Although there are no generally accepted methods, the licensing authority is still required to take into account dependent failures in a probabilistic safety analysis; - (ii) the frequency of postulated initiating events implies which I and C functionality should be implemented on diverse equipment. Using non-safety I and C equipment in addition to safety I and C equipment is attractive because its necessary unavailability to control an initiating event in teamwork with the safety I and C equipment is estimated to range from 0.01 to 0.1. This can be achieved by operational experience

  18. The EORTC emotional functioning computerized adaptive test

    DEFF Research Database (Denmark)

    Gamper, Eva-Maria; Grønvold, Mogens; Petersen, Morten Aa

    2014-01-01

    The European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Group is currently developing computerized adaptive testing measures for the Quality of Life Questionnaire Core-30 (QLQ-C30) scales. The work presented here describes the development of an EORTC item bank for e...... for emotional functioning (EF), which is one of the core domains of the QLQ-C30....

  19. 45 CFR 307.25 - Review and certification of computerized support enforcement systems.

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS § 307.25 Review and certification of computerized support enforcement systems. The Office will review, assess and inspect the... 45 Public Welfare 2 2010-10-01 2010-10-01 false Review and certification of computerized support...

  20. WindoWorks: A flexible program for computerized testing of accelerator control system electronic circuit boards

    International Nuclear Information System (INIS)

    Utterback, J.

    1993-09-01

    Since most accelerator control system circuit boards reside in a commercial bus architecture, such as CAMAC or VMEbus, a computerized test station is needed for exercising the boards. This test station is needed for the development of newly designed prototypes, for commissioning newly manufactured boards, for diagnosing boards which have failed in service, and for long term testing of boards with intermittent failure problems. WindoWorks was created to address these needs. It is a flexible program which runs on a PC compatible computer and uses a PC to bus crate interface. WindoWorks was designed to give the user a flexible way to test circuit boards. Each test is incapsulated into a window. By bringing up several different windows the user can run several different tests simultaneously. The windows are sizable, and moveable. They have data entry boxes so that the test can be customized to the users preference. The windows can be used in conjunction with each other in order to create supertests. There are several windows which are generic. They can be used to test basic functions on any VME (or CAMAC) board. There are other windows which have been created to test specific boards. New windows for testing specific boards can be easily created by a Pascal programmer using the WindoWorks framework

  1. Modernizing computerized nuclear material accounting systems

    International Nuclear Information System (INIS)

    Erkkila, B.H.; Claborn, J.

    1995-01-01

    DOE Orders and draft orders for nuclear material control and accountability address a complete material control and accountability (MC and A) program for all DOE contractors processing, using, or storing nuclear materials. A critical element of an MC and A program is the accounting system used to track and record all inventories of nuclear material and movements of materials in those inventories. Most DOE facilities use computerized accounting systems to facilitate the task of accounting for all their inventory of nuclear materials. Many facilities still use a mixture of a manual paper system with a computerized system. Also, facilities may use multiple systems to support information needed for MC and A. For real-time accounting it is desirable to implement a single integrated data base management system for a variety of users. In addition to accountability needs, waste management, material management, and production operations must be supported. Information in these systems can also support criticality safety and other safety issues. Modern networked microcomputers provide extensive processing and reporting capabilities that single mainframe computer systems struggle with. This paper describes an approach being developed at Los Alamos to address these problems

  2. Multidimensional Computerized Adaptive Testing for Indonesia Junior High School Biology

    Science.gov (United States)

    Kuo, Bor-Chen; Daud, Muslem; Yang, Chih-Wei

    2015-01-01

    This paper describes a curriculum-based multidimensional computerized adaptive test that was developed for Indonesia junior high school Biology. In adherence to the Indonesian curriculum of different Biology dimensions, 300 items was constructed, and then tested to 2238 students. A multidimensional random coefficients multinomial logit model was…

  3. Computerized 50 liter volume calibration system

    International Nuclear Information System (INIS)

    Proffitt, T.H.

    1990-01-01

    A system has been designed for the Savannah River Site that will be used to calibrate product shipping containers. For accountability purposes, it is necessary that these containers be calibrated to a very high precision. The Computerized 50 Liter Volume Calibration System (CVCS), which is based on the Ideal Gas Law (IGL), will use reference volumes with precision of no less ±0.03%, and helium to calibrate the containers to have a total error of no greater than ±0.10%. A statistical interpretation of the system has given a theoretical total calculated error of ±0.08%. Tests with the system will be performed once fabrication is complete to experimentally verify the calculated error. Since the total error was calculated using the worst case scenario, the actual error should be significantly less than the calculated value. The computer controlled, totally automated system is traceable to the National Institute of Standards and Technology. The design, calibration procedure, and statistical interpretation of the system will be discussed. 1 ref

  4. Multiple Maximum Exposure Rates in Computerized Adaptive Testing

    Science.gov (United States)

    Ramon Barrada, Juan; Veldkamp, Bernard P.; Olea, Julio

    2009-01-01

    Computerized adaptive testing is subject to security problems, as the item bank content remains operative over long periods and administration time is flexible for examinees. Spreading the content of a part of the item bank could lead to an overestimation of the examinees' trait level. The most common way of reducing this risk is to impose a…

  5. Computerized radiation control system in the Chernobyl 30-km zone

    International Nuclear Information System (INIS)

    Vasil'chenko, D.L.; Pis'mak, A.D.; Livertovskij, G.P.; Chikhladze, V.S.

    1992-01-01

    Computerized radiation control system is intended for monitoring radiation in the zone of radiation-hazardous objects for providing nuclear power station services with current information on radiactive situation in the zone of observation and the doses of radiation taken by the personnel. Described are tasks and functions of the system, as well as its structure. It is noted that unique conditions of the Chernobyl' 30-km zone open up opportunities for experiments and testing new models of equipment. 2 figs

  6. Computerized provider order entry systems.

    Science.gov (United States)

    2001-01-01

    Computerized provider order entry (CPOE) systems are designed to replace a hospital's paper-based ordering system. They allow users to electronically write the full range of orders, maintain an online medication administration record, and review changes made to an order by successive personnel. They also offer safety alerts that are triggered when an unsafe order (such as for a duplicate drug therapy) is entered, as well as clinical decision support to guide caregivers to less expensive alternatives or to choices that better fit established hospital protocols. CPOE systems can, when correctly configured, markedly increase efficiency and improve patient safety and patient care. However, facilities need to recognize that currently available CPOE systems require a tremendous amount of time and effort to be spent in customization before their safety and clinical support features can be effectively implemented. What's more, even after they've been customized, the systems may still allow certain unsafe orders to be entered. Thus, CPOE systems are not currently a quick or easy remedy for medical errors. ECRI's Evaluation of CPOE systems--conducted in collaboration with the Institute for Safe Medication Practices (ISMP)--discusses these and other related issues. It also examines and compares CPOE systems from three suppliers: Eclipsys Corp., IDX Systems Corp., and Siemens Medical Solutions Health Services Corp. Our testing focuses primarily on the systems' interfacing capabilities, patient safeguards, and ease of use.

  7. Computerized systems of NPP operators support. (Psychological problems)

    International Nuclear Information System (INIS)

    Mashin, V.A.

    1995-01-01

    Operator psychological problems arising in the work with NPP operators support computerized systems (OSCS) are considered. The conclusion is made that the OSCS intellectual application will bring the operator into dangerous dependence on his computerized assistant. To avoid this danger it is necessary by creation of the OSCS to divide specially the tasks areas of the operator and OSCS in order to assure the active role of the operator in the NPP control

  8. Computerized Tests of Team Performance and Crew Coordination Suitable for Military/Aviation Settings.

    Science.gov (United States)

    Lawson, Ben D; Britt, Thomas W; Kelley, Amanda M; Athy, Jeremy R; Legan, Shauna M

    2017-08-01

    The coordination of team effort on shared tasks is an area of inquiry. A number of tests of team performance in challenging environments have been developed without comparison or standardization. This article provides a systematic review of the most accessible and usable low-to-medium fidelity computerized tests of team performance and determines which are most applicable to military- and aviation-relevant research, such as studies of group command, control, communication, and crew coordination. A search was conducted to identify computerized measures of team performance. In addition to extensive literature searches (DTIC, Psychinfo, PubMed), the authors reached out to team performance researchers at conferences and through electronic communication. Identified were 57 potential tests according to 6 specific selection criteria (e.g., the requirement for automated collection of team performance and coordination processes, the use of military-relevant scenarios). The following seven tests (listed alphabetically) were considered most suitable for military needs: Agent Enabled Decision Group Environment (AEDGE), C3Conflict, the C3 (Command, Control, & Communications) Interactive Task for Identifying Emerging Situations (NeoCITIES), Distributed Dynamic Decision Making (DDD), Duo Wondrous Original Method Basic Awareness/Airmanship Test (DuoWOMBAT), the Leader Development Simulator (LDS), and the Planning Task for Teams (PLATT). Strengths and weaknesses of these tests are described and recommendations offered to help researchers identify the test most suitable for their particular needs. Adoption of a few standard computerized test batteries to study team performance would facilitate the evaluation of interventions intended to enhance group performance in multiple challenging military and aerospace operational environments.Lawson BD, Britt TW, Kelley AM, Athy JR, Legan SM. Computerized tests of team performance and crew coordination suitable for military/aviation settings

  9. A multiple objective test assembly approach for exposure control problems in Computerized Adaptive Testing

    Directory of Open Access Journals (Sweden)

    Theo J.H.M. Eggen

    2010-01-01

    Full Text Available Overexposure and underexposure of items in the bank are serious problems in operational computerized adaptive testing (CAT systems. These exposure problems might result in item compromise, or point at a waste of investments. The exposure control problem can be viewed as a test assembly problem with multiple objectives. Information in the test has to be maximized, item compromise has to be minimized, and pool usage has to be optimized. In this paper, a multiple objectives method is developed to deal with both types of exposure problems. In this method, exposure control parameters based on observed exposure rates are implemented as weights for the information in the item selection procedure. The method does not need time consuming simulation studies, and it can be implemented conditional on ability level. The method is compared with Sympson Hetter method for exposure control, with the Progressive method and with alphastratified testing. The results show that the method is successful in dealing with both kinds of exposure problems.

  10. Computerized dosimetry management systems within EDF

    International Nuclear Information System (INIS)

    Daubert, G.

    1996-01-01

    EDF, using the ALARA approach, has embarked an ambitious project of optimising the doses received in its power plants. In directing its choice of actions and the effectiveness of such actions, the French operator is using a computerized personal and collective dosimetry management system. This system provides for ongoing monitoring of dosimetry at personal, site and unit level or indeed for the entire population of EDF nuclear power plants. (author)

  11. Computerized reactor pressure vessel materials information system

    International Nuclear Information System (INIS)

    Strosnider, J.; Monserrate, C.; Kenworthy, L.D.; Tether, C.D.

    1980-10-01

    A computerized information system for storage and retrieval of reactor pressure vessel materials data was established, as part of Task Action Plan A-11, Reactor Vessel Materials Toughness. Data stored in the system are necessary for evaluating the resistance of reactor pressure vessels to flaw-induced fracture. This report includes (1) a description of the information system; (2) guidance on accessing the system; and (3) a user's manual for the system

  12. Estimation of an Examinee's Ability in the Web-Based Computerized Adaptive Testing Program IRT-CAT

    Directory of Open Access Journals (Sweden)

    Yoon-Hwan Lee

    2006-11-01

    Full Text Available We developed a program to estimate an examinee's ability in order to provide freely available access to a web-based computerized adaptive testing (CAT program. We used PHP and Java Script as the program languages, PostgresSQL as the database management system on an Apache web server and Linux as the operating system. A system which allows for user input and searching within inputted items and creates tests was constructed. We performed an ability estimation on each test based on a Rasch model and 2- or 3-parametric logistic models. Our system provides an algorithm for a web-based CAT, replacing previous personal computer-based ones, and makes it possible to estimate an examinee?占퐏 ability immediately at the end of test.

  13. Computerized Italian criticality guide, description and validation

    International Nuclear Information System (INIS)

    Carotenuto, M.; Landeyro, P.A.

    1988-10-01

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  14. Computerized Italian criticality guide, description and validation

    Energy Technology Data Exchange (ETDEWEB)

    Carotenuto, M; Landeyro, P A [ENEA - Dipartimento Ciclo del Combustibile, Centro Ricerche Energia, Casaccia (Italy)

    1988-10-15

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  15. Man-mashine communication improvements in computerized operator support system by new technologies

    International Nuclear Information System (INIS)

    Tai, I.; Seki, E.; Fukumoto, A.; Mori, N.; Tsuchida, M.; Itoh, J.; Tanaka, K.

    1984-01-01

    Improvement of the man-machine interface performance is under way as Computerized Operator Support System for nuclear power plants in Japan. This paper describes several improved points in the design of man-mashine interface, especially on the console, based on the evaluation of the conventional design and by taking into account the performance test results of new man-machine interfacing tools. (author)

  16. A computerized stroop test for the evaluation of psychotropic drugs in healthy participants.

    Science.gov (United States)

    Pilli, Raveendranadh; Naidu, Mur; Pingali, Usha Rani; Shobha, J C; Reddy, A Praveen

    2013-04-01

    The Stroop paradigm evaluates susceptibility to interference and is sensitive to dysfunction in frontal lobes and drug effects. The aim of the present study was to establish a simple and reliable computerized version of Stroop color-word test, which can be used for screening of various psychotropic drugs. The standardized method was followed in all cases, by recording the reaction time (RT) in msec in 24 healthy participants using computerized version of Stroop color-word test. Reproducibility of the test procedure was evaluated by recording the RTs by a single experimenter on two sessions (interday reproducibility). Validity of the model was further tested by evaluating the psychotropic effect of Zolpidem 5 mg, Caffeine 500 mg, or Placebo on 24 healthy subjects in a randomized, double blind three-way crossover design. The method was found to produce low variability with coefficient of variation less than 10%. Interday reproducibility was very good as shown by Bland-Altman plot with most of the values within ±2SD. There was a significant increase in RTs in Stroop performance with Zolpidem at 1 hr and 2 hrs; in contrast, caffeine significantly decreased RTs in Stroop performance at 1 hr only compared to placebo. The Stroop color-word recording and analysis system is simple, sensitive to centrally acting drug effects, and has potential for future experimental psychomotor assessment studies.

  17. Improving the utility of the fine motor skills subscale of the comprehensive developmental inventory for infants and toddlers: a computerized adaptive test.

    Science.gov (United States)

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Chou, Willy; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2017-07-27

    This study aimed at improving the utility of the fine motor subscale of the comprehensive developmental inventory for infants and toddlers (CDIIT) by developing a computerized adaptive test of fine motor skills. We built an item bank for the computerized adaptive test of fine motor skills using the fine motor subscale of the CDIIT items fitting the Rasch model. We also examined the psychometric properties and efficiency of the computerized adaptive test of fine motor skills with simulated computerized adaptive tests. Data from 1742 children with suspected developmental delays were retrieved. The mean scores of the fine motor subscale of the CDIIT increased along with age groups (mean scores = 1.36-36.97). The computerized adaptive test of fine motor skills contains 31 items meeting the Rasch model's assumptions (infit mean square = 0.57-1.21, outfit mean square = 0.11-1.17). For children of 6-71 months, the computerized adaptive test of fine motor skills had high Rasch person reliability (average reliability >0.90), high concurrent validity (rs = 0.67-0.99), adequate to excellent diagnostic accuracy (area under receiver operating characteristic = 0.71-1.00), and large responsiveness (effect size = 1.05-3.93). The computerized adaptive test of fine motor skills used 48-84% fewer items than the fine motor subscale of the CDIIT. The computerized adaptive test of fine motor skills used fewer items for assessment but was as reliable and valid as the fine motor subscale of the CDIIT. Implications for Rehabilitation We developed a computerized adaptive test based on the comprehensive developmental inventory for infants and toddlers (CDIIT) for assessing fine motor skills. The computerized adaptive test has been shown to be efficient because it uses fewer items than the original measure and automatically presents the results right after the test is completed. The computerized adaptive test is as reliable and valid as the CDIIT.

  18. A three-dimensional computerized isometric strength measurement system.

    Science.gov (United States)

    Black, Nancy L; Das, Biman

    2007-05-01

    The three-dimensional Computerized Isometric Strength Measurement System (CISMS) reliably and accurately measures isometric pull and push strengths in work spaces of paraplegic populations while anticipating comparative studies with other populations. The main elements of the system were: an extendable arm, a vertical supporting track, a rotating platform, a force transducer, stability sensors and a computerized data collection interface. The CISMS with minor modification was successfully used to measure isometric push-up and pull-down strengths of paraplegics and isometric push, pull, push-up and pull-down strength in work spaces for seated and standing able-bodied populations. The instrument has satisfied criteria of versatility, safety and comfort, ease of operation, and durability. Results are accurate within 2N for aligned forces. Costing approximately $1,500 (US) including computer, the system is affordable and accurate for aligned isometric strength measurements.

  19. Evaluation of computerized health management information system for primary health care in rural India

    Directory of Open Access Journals (Sweden)

    Singh Satyavir

    2010-11-01

    Full Text Available Abstract Background The Comprehensive Rural Health Services Project Ballabgarh, run by All India Institute of Medical Sciences (AIIMS, New Delhi has a computerized Health Management Information System (HMIS since 1988. The HMIS at Ballabgarh has undergone evolution and is currently in its third version which uses generic and open source software. This study was conducted to evaluate the effectiveness of a computerized Health Management Information System in rural health system in India. Methods The data for evaluation were collected by in-depth interviews of the stakeholders i.e. program managers (authors and health workers. Health Workers from AIIMS and Non-AIIMS Primary Health Centers were interviewed to compare the manual with computerized HMIS. A cost comparison between the two methods was carried out based on market costs. The resource utilization for both manual and computerized HMIS was identified based on workers' interviews. Results There have been no major hardware problems in use of computerized HMIS. More than 95% of data was found to be accurate. Health workers acknowledge the usefulness of HMIS in service delivery, data storage, generation of workplans and reports. For program managers, it provides a better tool for monitoring and supervision and data management. The initial cost incurred in computerization of two Primary Health Centers was estimated to be Indian National Rupee (INR 1674,217 (USD 35,622. Equivalent annual incremental cost of capital items was estimated as INR 198,017 (USD 4213. The annual savings is around INR 894,283 (USD 11,924. Conclusion The major advantage of computerization has been in saving of time of health workers in record keeping and report generation. The initial capital costs of computerization can be recovered within two years of implementation if the system is fully operational. Computerization has enabled implementation of a good system for service delivery, monitoring and supervision.

  20. Hybrid Computerized Adaptive Testing: From Group Sequential Design to Fully Sequential Design

    Science.gov (United States)

    Wang, Shiyu; Lin, Haiyan; Chang, Hua-Hua; Douglas, Jeff

    2016-01-01

    Computerized adaptive testing (CAT) and multistage testing (MST) have become two of the most popular modes in large-scale computer-based sequential testing. Though most designs of CAT and MST exhibit strength and weakness in recent large-scale implementations, there is no simple answer to the question of which design is better because different…

  1. A computerized system for improved management and execution of plant procedures

    International Nuclear Information System (INIS)

    Lipner, M.H.; Orendi, R.G.; Impink, A.J.; Mundy, R.A.

    1987-01-01

    The authors have shown how the deficiencies reported in this paper can be resolved by using the Computerized Procedures System. The Westinghouse Computerized Procedures System solves many of the human performance problems associated with procedures. It has been designed to assist plant operators in executing procedures more efficiently and cost effectively. The system brings all of the necessary information to one location for easy and continuous assessment of plant conditions and permits the operator to concentrate on the big picture

  2. Computerized Adaptive Test vs. decision trees: Development of a support decision system to identify suicidal behavior.

    Science.gov (United States)

    Delgado-Gomez, D; Baca-Garcia, E; Aguado, D; Courtet, P; Lopez-Castroman, J

    2016-12-01

    Several Computerized Adaptive Tests (CATs) have been proposed to facilitate assessments in mental health. These tests are built in a standard way, disregarding useful and usually available information not included in the assessment scales that could increase the precision and utility of CATs, such as the history of suicide attempts. Using the items of a previously developed scale for suicidal risk, we compared the performance of a standard CAT and a decision tree in a support decision system to identify suicidal behavior. We included the history of past suicide attempts as a class for the separation of patients in the decision tree. The decision tree needed an average of four items to achieve a similar accuracy than a standard CAT with nine items. The accuracy of the decision tree, obtained after 25 cross-validations, was 81.4%. A shortened test adapted for the separation of suicidal and non-suicidal patients was developed. CATs can be very useful tools for the assessment of suicidal risk. However, standard CATs do not use all the information that is available. A decision tree can improve the precision of the assessment since they are constructed using a priori information. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Computerized tomographic system

    International Nuclear Information System (INIS)

    Godbarsen, R.; Barrett, D.M.; Garrott, P.M.; Foley, L.E.; Redington, R.W.; Lambert, T.W.; Edelheit, L.S.

    1981-01-01

    A computerized tomographic system for examining human breasts is described in detail. Conventional X-ray scanning apparatus has difficulty in achieving the levels of image definition and examination speeds required for mass screening. A novel method of scanning successive layers of the breast with a rotating X-ray beam is discussed and details of the control circuitry and sequence steps are given. The method involves immersing the breast in an inner fluid (e.g. water) filled container which is stationary during an examination and is surrounded by a large outer container which is also filled with the fluid; the inner and outer containers are always maintained at a constant height and the X-ray absorption across the fan-shaped beam is as close as possible to constant. (U.K.)

  4. A Framework for the Development of Computerized Adaptive Tests

    Directory of Open Access Journals (Sweden)

    Nathan A. Thompson

    2011-01-01

    Full Text Available A substantial amount of research has been conducted over the past 40 years on technical aspects of computerized adaptive testing (CAT, such as item selection algorithms, item exposure controls, and termination criteria. However, there is little literature providing practical guidance on the development of a CAT. This paper seeks to collate some of the available research methodologies into a general framework for the development of any CAT assessment.

  5. Self-Assessment, Preparation and Response Time on a Computerized Oral Proficiency Test

    Science.gov (United States)

    Malabonga, Valerie; Kenyon, Dorry M.; Carpenter, Helen

    2005-01-01

    Two studies investigated technical aspects of a computer-mediated test, the Computerized Oral Proficiency Instrument (COPI), particularly in contrast to a similar tape-mediated test, the Simulated Oral Proficiency Interview (SOPI). The first study investigated how examinees used self-assessment to choose an appropriate starting level on the COPI.…

  6. Detection of person misfit in computerized adaptive tests with polytomous items

    NARCIS (Netherlands)

    van Krimpen-Stoop, Edith; Meijer, R.R.

    2000-01-01

    Item scores that do not fit an assumed item response theory model may cause the latent trait value to be estimated inaccurately. For computerized adaptive tests (CAT) with dichotomous items, several person-fit statistics for detecting nonfitting item score patterns have been proposed. Both for

  7. Strategy generator in computerized accident management support system

    International Nuclear Information System (INIS)

    Sirola, M.

    1994-02-01

    An increased interest for research in the field of accident management of nuclear power plants can be noted. Several international programmes have been started in order to be able to understand the basic physical and chemical phenomena in accident conditions. A feasibility study has shown that it would be possible to design and develop a computerized support system for plant staff in accident situations. To achieve this goal the Halden Project has initiated a research programme on Computerized Accident Management Support (CAMS project). The aim is to utilize the capabilities of computerized tools to support the plant staff during the various accident stages. The system will include identification of the accident state, assessment of the future development of the accident and planning of accident mitigation strategies. A prototype is developed to support operators and the Technical Support Centre in decision making during serious accidents in nuclear power plants. A rule based system has been built to take care of the strategy generation. This system assists plant personnel in planning control proposals and mitigation strategies from normal operation to severe accident conditions. The idea of a safety objective tree and knowledge from the emergency procedures have been used. Future prediction requires good state identification of the plant status and some knowledge about the history of some critical variables. The information needs to be validated as well. Accurate calculations in simulators and a large database including all important information from the plant will help the strategy planning. (orig.). (40 refs., 20 figs.)

  8. Computerized management information systems and organizational structures

    Science.gov (United States)

    Zannetos, Z. S.; Sertel, M. R.

    1970-01-01

    The computerized management of information systems and organizational structures is discussed. The subjects presented are: (1) critical factors favoring centralization and decentralization of organizations, (2) classification of organizations by relative structure, (3) attempts to measure change in organization structure, and (4) impact of information technology developments on organizational structure changes.

  9. The computerized reactor period measurement system for China fast burst reactor-II

    International Nuclear Information System (INIS)

    Zhao Wuwen; Jiang Zhiguo

    1996-01-01

    The article simply introduces the hardware, principle, and software of the computerized reactor period measurement system for China Fast Burst Reactor-II (CFBR-II). It also gives the relation between fission yield and pre-reactivity of CFBR-II reactor system of bared reactor with decoupled-component and system of bared reactor with multiple light-material. The computerized measurement system makes the reactor period measurement into automatical and intelligent and also improves the speed and precision of period data on-line process

  10. Computerized accounting methods. Final report

    International Nuclear Information System (INIS)

    1994-01-01

    This report summarizes the results of the research performed under the Task Order on computerized accounting methods in a period from 03 August to 31 December 1994. Computerized nuclear material accounting methods are analyzed and evaluated. Selected methods are implemented in a hardware-software complex developed as a prototype of the local network-based CONMIT system. This complex has been put into trial operation for test and evaluation of the selected methods at two selected ''Kurchatov Institute'' Russian Research Center (''KI'' RRC) nuclear facilities. Trial operation is carried out since the beginning of Initial Physical Inventory Taking in these facilities that was performed in November 1994. Operation of CONMIT prototype system was demonstrated in the middle of December 1994. Results of evaluation of CONMIT prototype system features and functioning under real operating conditions are considered. Conclusions are formulated on the ways of further development of computerized nuclear material accounting methods. The most important conclusion is a need to strengthen computer and information security features supported by the operating environment. Security provisions as well as other LANL Client/Server System approaches being developed by Los Alamos National Laboratory are recommended for selection of software and hardware components to be integrated into production version of CONMIT system for KI RRC

  11. A Comparison of Procedures for Content-Sensitive Item Selection in Computerized Adaptive Tests.

    Science.gov (United States)

    Kingsbury, G. Gage; Zara, Anthony R.

    1991-01-01

    This simulation investigated two procedures that reduce differences between paper-and-pencil testing and computerized adaptive testing (CAT) by making CAT content sensitive. Results indicate that the price in terms of additional test items of using constrained CAT for content balancing is much smaller than that of using testlets. (SLD)

  12. A Computerized Version of the Scrambled Sentences Test

    Directory of Open Access Journals (Sweden)

    Roberto Viviani

    2018-01-01

    Full Text Available The scrambled sentences test (SST, an experimental procedure that involves participants writing down their cognitions, has been used to elicit individual differences in depressiveness and vulnerability to depression. We describe here a modification of the SST to adapt it to computerized administration, with a particular view of its use in large samples and functional neuroimaging applications. In a first study with the computerized version, we reproduce the preponderance of positive cognitions in the healthy and the inverse association of these cognitions with individual measures of depressiveness. We also report a tendency of self-referential cognitions to elicit higher positive cognition rates. In a second study, we describe the patterns of neural activations elicited by emotional and neutral sentences in a functional neuroimaging study, showing that it replicates and extends previous findings obtained with the original version of the SST. During the formation of emotional cognitions, ventral areas such as the ventral anterior cingulus and the supramarginal gyrus were relatively activated. This activation pattern speaks for the recruitment of mechanisms coordinating motivational and associative processes in the formation of value-based decisions.

  13. Integrating bar-code devices with computerized MC and A systems

    International Nuclear Information System (INIS)

    Anderson, L.K.; Boor, M.G.; Hurford, J.M.

    1998-01-01

    Over the past seven years, Los Alamos National Laboratory developed several generations of computerized nuclear materials control and accountability (MC and A) systems for tracking and reporting the storage, movement, and management of nuclear materials at domestic and international facilities. During the same period, Oak Ridge National Laboratory was involved with automated data acquisition (ADA) equipment, including installation of numerous bar-code scanning stations at various facilities to serve as input devices to computerized systems. Bar-code readers, as well as other ADA devices, reduce input errors, provide faster input, and allow the capture of data in remote areas where workstations do not exist. Los Alamos National Laboratory and Oak Ridge National Laboratory teamed together to implement the integration of bar-code hardware technology with computerized MC and A systems. With the expertise of both sites, the two technologies were successfully merged with little difficulty. Bar-code input is now available with several functions of the MC and A systems: material movements within material balance areas (MBAs), material movements between MBAs, and physical inventory verification. This paper describes the various components required for the integration of these MC and A systems with the installed bar-code reader devices and the future directions for these technologies

  14. Density evaluation by computerized tomography in plain soils over different manipulation systems

    International Nuclear Information System (INIS)

    Pedrotti, Alceu

    1996-08-01

    The objective of this paper is the evaluation of a plain soil density in different culture systems determined by X ray computerized tomography.It was observed a larger variation in densities in soils profiles analysed. The identification of layers is better utilising computerized tomography than others technic

  15. [Computerized ranking test in three French universities: Staff experience and students' feedback].

    Science.gov (United States)

    Roux, D; Meyer, G; Cymbalista, F; Bouaziz, J-D; Falgarone, G; Tesniere, A; Gervais, J; Cariou, A; Peffault de Latour, R; Marat, M; Moenaert, E; Guebli, T; Rodriguez, O; Lefort, A; Dreyfuss, D; Hajage, D; Ricard, J-D

    2016-03-01

    The year 2016 will be pivotal for the evaluation of French medical students with the introduction of the first computerized National Ranking Test (ECNi). The SIDES, online electronic system for medical student evaluation, was created for this purpose. All the universities have already organized faculty exams but few a joint computerized ranking test at several universities simultaneously. We report our experience on the organization of a mock ECNi by universities Paris Descartes, Paris Diderot and Paris 13. Docimological, administrative and technical working groups were created to organize this ECNi. Students in their fifth year of medical studies, who will be the first students to sit for the official ECNi in 2016, were invited to attend this mock exam that represented more than 50% of what will be proposed in 2016. A final electronic questionnaire allowed a docimological and organizational evaluation by students. An analysis of ratings and rankings and their distribution on a 1000-point scale were performed. Sixty-four percent of enrolled students (i.e., 654) attended the three half-day exams. No difference in total score and ranking between the three universities was observed. Students' feedback was extremely positive. Normalized over 1000 points, 99% of students were scored on 300 points only. Progressive clinical cases were the most discriminating test. The organization of a mock ECNi involving multiple universities was a docimological and technical success but required an important administrative, technical and teaching investment. Copyright © 2016 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  16. A study on a systematic approach of verification and validation of a computerized procedure system: ImPRO

    International Nuclear Information System (INIS)

    Qin, Wei; Seong, Poong Hyun

    2003-01-01

    Paper Based Procedure (PBP) and Computerized Procedure System (CPS) are studied to demonstrate that it is necessary to develop CPS in NPP I and C system. Computerized procedure system is actually a software system. All the desired and undesired properties of a software system can be described and evaluated as software qualities. Generally, software qualities can be categorized into product quality and process quality. In order to achieve product quality, the process quality of a software system should also be considered and achieved. Characteristics of CPS will be described to analyse the product and process of an example CPS: ImPRO. At the same time, several main product and process issues will be analysed from Verification and Validation (V and V) point of view. It is concluded and suggested that V and V activities can also be regarded as software development process, this point of view then is applied to the V and V activities of ImPRO as a systematic approach of V and V of ImPRO. To support and realize this approach, suitable testing technologies and testing strategies are suggested

  17. 45 CFR 310.5 - What options are available for Computerized Tribal IV-D Systems and office automation?

    Science.gov (United States)

    2010-10-01

    ... IV-D Systems and office automation? 310.5 Section 310.5 Public Welfare Regulations Relating to Public... AUTOMATION Requirements for Computerized Tribal IV-D Systems and Office Automation § 310.5 What options are available for Computerized Tribal IV-D Systems and office automation? (a) Allowable computerized support...

  18. Evaluation of an ontology-based system for computerized cognitive rehabilitation.

    Science.gov (United States)

    Alloni, Anna; Quaglini, Silvana; Panzarasa, Silvia; Sinforiani, Elena; Bernini, Sara

    2018-07-01

    This paper describes the results of a randomized clinical trial about the effectiveness of a computerized rehabilitation treatment on a sample of 31 patients affected by Parkinson disease. Computerized exercises were administered by the therapists to the intervention group (n = 17) through the CoRe tool, which automatically generates a big variety of exercises leveraging on a stimuli set (words, sounds and images) organized into a dedicated ontology. A battery of standard neuropsychological tests was performed for patients' assessment at baseline, after the treatment (that lasted 1 month), and after 6 months from the treatment stop. The control group underwent a sham intervention. Results show a statistically significant clinical benefit from computerized rehabilitation with respect to sham treatment. For the intervention group, response time and response accuracy were integrated into a weighted score that accounts also for the specific cognitive burden of each exercise. Differently from the control group, the majority of patients in the intervention group showed an improvement in that score, more marked in the first week of treatment, and which lasts for the entire treatment period, which could account both for a quick learning effect and for an improvement of cognitive conditions. Good usability of CoRe, already observed in previous studies, was confirmed by the present trial, where the percentage of protocol completion in the intervention group is very high (all but one patient are above 90%). The CoRe system showed to be effective to improve some cognitive abilities in patients with Parkinson disease. However, after the end of the training, the benefit is hardly maintained over time. These findings support the implementation of CoRe in the clinical routine and the continuation of the treatment after discharge through the use of a homecare version of the system. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. A Computerized Clinical Support System and Psychological Laboratory.

    Science.gov (United States)

    Cassel, Russell N.

    1978-01-01

    Advocating "holistic" medicine, this article details the benefits to be derived from using a computerized clinical support system in a psychological laboratory focusing on internal healing where the client/patient becomes a committed partner utilizing biofeedback equipment, gaming, and simulation to achieve self-understanding and…

  20. 45 CFR 307.13 - Security and confidentiality for computerized support enforcement systems in operation after...

    Science.gov (United States)

    2010-10-01

    ... ENFORCEMENT SYSTEMS § 307.13 Security and confidentiality for computerized support enforcement systems in... systems in operation after October 1, 1997. (a) Information integrity and security. Have safeguards... 45 Public Welfare 2 2010-10-01 2010-10-01 false Security and confidentiality for computerized...

  1. Computerized test versus personal interview as admission methods for graduate nursing studies: A retrospective cohort study.

    Science.gov (United States)

    Hazut, Koren; Romem, Pnina; Malkin, Smadar; Livshiz-Riven, Ilana

    2016-12-01

    The purpose of this study was to compare the predictive validity, economic efficiency, and faculty staff satisfaction of a computerized test versus a personal interview as admission methods for graduate nursing studies. A mixed method study was designed, including cross-sectional and retrospective cohorts, interviews, and cost analysis. One hundred and thirty-four students in the Master of Nursing program participated. The success of students in required core courses was similar in both admission method groups. The personal interview method was found to be a significant predictor of success, with cognitive variables the only significant contributors to the model. Higher satisfaction levels were reported with the computerized test compared with the personal interview method. The cost of the personal interview method, in annual hourly work, was 2.28 times higher than the computerized test. These findings may promote discussion regarding the cost benefit of the personal interview as an admission method for advanced academic studies in healthcare professions. © 2016 John Wiley & Sons Australia, Ltd.

  2. Development of a computerized tomographic system

    International Nuclear Information System (INIS)

    Borges, J.C.; Santos, C.A.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory at COPPE/UFRJ has been developing techniques for detection and applications of nuclear radiations. A lot of research work has been done and resulted in several M.Sc. and D.Sc. thesis, concerning subjects like neutrongraphy, gammagraphy, image reconstruction, special detectors, etc. Recent progress and multiple applications of the computerized tomography to medical and industrial non-destructive tests, pushed the Laboratory to a vast program in this field of research. In this paper, we report what has been done and the results obtained. (Author) [pt

  3. Implementation of a Computerized Screening Inventory: Improved Usability Through Iterative Testing and Modification.

    Science.gov (United States)

    Boudreaux, Edwin D; Fischer, Andrew Christopher; Haskins, Brianna Lyn; Saeed Zafar, Zubair; Chen, Guanling; Chinai, Sneha A

    2016-03-09

    The administration of health screeners in a hospital setting has traditionally required (1) clinicians to ask questions and log answers, which can be time consuming and susceptible to error, or (2) patients to complete paper-and-pencil surveys, which require third-party entry of information into the electronic health record and can be vulnerable to error and misinterpretation. A highly promising method that avoids these limitations and bypasses third-party interpretation is direct entry via a computerized inventory. To (1) computerize medical and behavioral health screening for use in general medical settings, (2) optimize patient acceptability and feasibility through iterative usability testing and modification cycles, and (3) examine how age relates to usability. A computerized version of 15 screeners, including behavioral health screeners recommended by a National Institutes of Health Office of Behavioral and Social Sciences Research collaborative workgroup, was subjected to systematic usability testing and iterative modification. Consecutive adult, English-speaking patients seeking treatment in an urban emergency department were enrolled. Acceptability was defined as (1) the percentage of eligible patients who agreed to take the assessment (initiation rate) and (2) average satisfaction with the assessment (satisfaction rate). Feasibility was defined as the percentage of the screening items completed by those who initiated the assessment (completion rate). Chi-square tests, analyses of variance, and Pearson correlations were used to detect whether improvements in initiation, satisfaction, and completion rates were seen over time and to examine the relation between age and outcomes. Of 2157 eligible patients approached, 1280 agreed to complete the screening (initiation rate=59.34%). Statistically significant increases were observed over time in satisfaction (F3,1061=3.35, P=.019) and completion rates (F3,1276=25.44, PUsability testing revealed several critical

  4. Computerized commodity management system in Thailand and Brazil.

    Science.gov (United States)

    1984-01-01

    Thailand's National Family Planning Program is testing a computerized contraceptive commodity reporting management in 4 provinces with 104 National Family Planning Program (NFPP) reporting entities. Staff in the Brazilian Association of Family Planning Entities (ABEPF) and CPAIMC, a major family planning service agency, have been trained in the use of a computerized commodity distribution management system and are ready to initiate test use. The systems were designed in response to specific commodity management needs of the concerned organizations. Neither distribution program functions as a contraceptive social marketing (CSM) program, but each system reviewed has aspects that are relevant to CSM commodity management needs. Both the Thai and Brazilian systems were designed to be as automatic and user friendly as possible. Both have 3 main databases and perform similar management and reporting functions. Differing program configurations and basic data forms reflect the specific purposes of each system. Databases for the logistics monitoring system in Thailand arethe reporting entity (or ID) file; the current month's data file; and the master balance file. The data source is the basic reporting form that also serves as a Request and Issue Voucher for commodities. Editing functions in the program check to see that the current "beginning balance" equals the previous month's ending balance. Indexing functions in the system allow direct access to the records of any reporting entity via the ID number, as well as the sequential processing of records by ID number. 6 reports can be generated: status report by issuing entity; status report by dispensing entity; aggregate status report; out of compliance products report; out of compliance outlets report; and suggested shipment to regional warehouse report. Databases for the distribution management system in Brazil are: the name-ID (client institution) file; the product file; and the data file. The data source is an order form

  5. Implementation of a Computerized Maintenance Management System

    Science.gov (United States)

    Shen, Yong-Hong; Askari, Bruce

    1994-01-01

    A primer Computerized Maintenance Management System (CMMS) has been established for NASA Ames pressure component certification program. The CMMS takes full advantage of the latest computer technology and SQL relational database to perform periodic services for vital pressure components. The Ames certification program is briefly described and the aspects of the CMMS implementation are discussed as they are related to the certification objectives.

  6. Computerized x-ray radiographic system for fuel pellet measurements

    International Nuclear Information System (INIS)

    Green, D.R.; Karnesky, R.A.; Bromley, C.

    1977-01-01

    The development and operation of a computerized system for determination of fuel pellet diameters from x-ray radiography is described. Actual fuel pellet diameter measurements made with the system are compared to micrometer measurements on the same pellets, and statistically evaluated. The advantages and limitations of the system are discussed, and recommendations are made for further development

  7. Computerized UT system for stud bolt

    International Nuclear Information System (INIS)

    Kisanuki, T.; Uchida, K.; Fushimi, T.; Onda, K.

    1988-01-01

    Cracking of stud bolts used in steam turbine casing, valve and pressure vessel has caused concern regarding the safety and reliability of power plants. In order to detect harmful cracks in early state, the improvement of UT technique is required. As regarding the ultrasonic inspection technique, a longitudinal beam technique and/or an angle beam technique are generally used. The authors report their development of a computerized UT system for bolt inspection and improvement of the angle beam technique

  8. Optimizing the Use of Response Times for Item Selection in Computerized Adaptive Testing

    Science.gov (United States)

    Choe, Edison M.; Kern, Justin L.; Chang, Hua-Hua

    2018-01-01

    Despite common operationalization, measurement efficiency of computerized adaptive testing should not only be assessed in terms of the number of items administered but also the time it takes to complete the test. To this end, a recent study introduced a novel item selection criterion that maximizes Fisher information per unit of expected response…

  9. 381 Developing of a Computerized Brain Diagnosing System for ...

    African Journals Online (AJOL)

    User

    Ogunsanwo O. D. - Department of Computer Science, Gate way ICT ... computerized brain diagnosing system that would be used in carrying out the ..... This aspect explores the techniques use for the design of interface, menus and databases ...

  10. Human engineering considerations in designing a computerized controlled access security system

    International Nuclear Information System (INIS)

    Moore, J.W.; Banks, W.W.

    1988-01-01

    This paper describes a human engineering effort in the design of a major security system upgrade at Lawrence Livermore National Laboratory. This upgrade was to be accomplished by replacing obsolete and difficult-to-man (i.e., multiple operator task actions required) security equipment and systems with a new, automated, computer-based access control system. The initial task was to assist the electronic and mechanical engineering staff in designing a computerized security access system too functionally and ergonomically accommodate 100% of the Laboratory user population. The new computerized access system was intended to control entry into sensitive exclusion areas by requiring personnel to use an entry booth-based system and/or a remote access control panel system. The primary user interface with the system was through a control panel containing a magnetic card reader, function buttons, LCD display, and push-button keypad

  11. Evaluation of a computerized system for mechanical ventilation of infants.

    Science.gov (United States)

    Tehrani, Fleur T; Abbasi, Soraya

    2009-04-01

    To evaluate a computerized system for mechanical ventilation of infants. FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fraction of inspired oxygen (F(IO2)), minute ventilation, and control of weaning. It is used as an open-loop decision support system or as a closed-loop technique. Blood gas and ventilation data were collected from 12 infants in the neonatal intensive care at baseline and at the next round of evaluation. This data were input to open-loop version of FLEX. The system recommendations were compared to clinical determinations. FLEX recommended values for ventilation were on the average within 25% and 16.5% of the measured values at baseline and at the next round of evaluation, respectively. For F(IO2) and PEEP, FLEX recommended values were in general agreement with the clinical settings. FLEX recommendations for weaning were the same as the clinical determinations 50% of the time at baseline and 55% of the time at the next round of evaluation. FLEX did not recommend weaning for infants with weak spontaneous breathing effort or those who showed signs of dyspnea. A computerized system for mechanical ventilation is evaluated for treatment of infants. The results of the study show that the system has good potential for use in neonatal ventilatory care. Further refinements can be made in the system for very low-birth-weight infants.

  12. Validation of the computerized annunciation message list system (CAMLS)

    Energy Technology Data Exchange (ETDEWEB)

    Feher, M P; Davey, E C; Lupton, L R [AECL, Chalk River Labs., Chalk River, ON (Canada)

    1997-09-01

    The Computerized Annunciation Message List System is a computerized annunciation system for the control rooms of nuclear generating stations. CAMLS will alert operators to changes in plant conditions that may impact on safety and production and help staff to effectively respond. CAMLS is designed to: provide a clear and concise overview of the current problems or faults in the plant; provide an overview of the current state of the plant in terms of automatic process and equipment actions; provide support for specific operational tasks, through either pre-configured or operator-configured annunciation displays, including: rapid and efficient upset response, plant stabilization, problem diagnosis, recovery action planning and implementation, and rapid recovery from trip and return to power operation. To achieve this, several information processing, presentation,a nd interaction concepts were developed. 2 refs, 6 figs, 7 tabs.

  13. Validation of the computerized annunciation message list system (CAMLS)

    International Nuclear Information System (INIS)

    Feher, M.P.; Davey, E.C.; Lupton, L.R.

    1997-01-01

    The Computerized Annunciation Message List System is a computerized annunciation system for the control rooms of nuclear generating stations. CAMLS will alert operators to changes in plant conditions that may impact on safety and production and help staff to effectively respond. CAMLS is designed to: provide a clear and concise overview of the current problems or faults in the plant; provide an overview of the current state of the plant in terms of automatic process and equipment actions; provide support for specific operational tasks, through either pre-configured or operator-configured annunciation displays, including: rapid and efficient upset response, plant stabilization, problem diagnosis, recovery action planning and implementation, and rapid recovery from trip and return to power operation. To achieve this, several information processing, presentation,a nd interaction concepts were developed. 2 refs, 6 figs, 7 tabs

  14. Building the Vocational Phase of the Computerized Motor Skills Testing System for Use in the Electronics and Electrical Engineering Group and Hospitality Group

    Science.gov (United States)

    Hsiao, Hsien-Sheng; Chen, Jyun-Chen; Hong, Kunde

    2016-01-01

    Technical and vocational education emphasizes the development and training of hand motor skills. However, some problems exist in the current career and aptitude tests in that they do not truly measure the hand motor skills. This study used the Nintendo Wii Remote Controller as the testing device in developing a set of computerized testing tools to…

  15. Assessment of minimal hepatic encephalopathy (with emphasis on computerized psychometric tests).

    Science.gov (United States)

    Kappus, Matthew R; Bajaj, Jasmohan S

    2012-02-01

    Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life, and driving accidents. The detection of MHE requires specialized testing because it cannot, by definition, be diagnosed on standard clinical examination. Psychometric and neurophysiologic techniques are often used to test for MHE. Paper-pencil psychometric batteries and computerized tests have proved useful in diagnosing MHE and predicting its outcomes. Neurophysiologic tests also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike. Testing strategies depend on the normative data available, patient comfort, and local expertise. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Physician Acceptance of a Computerized Outpatient Medication System in a Teaching Hospital Group Practice

    OpenAIRE

    Blish, Christi; Proctor, Rita; Fletcher, Suzanne W.; O'Malley, Michael

    1983-01-01

    As part of a new automated ambulatory medical record, a computerized outpatient medication system was developed for a teaching hospital general medicine group practice. Seven months after its implementation, the system was evaluated to determine physician acceptance and approval. Practice physicians were surveyed, and 94% of the respondents approved of the system. Over 90% thought that the computerized system had improved the completeness and accuracy of medication information as well as thei...

  17. Minicomputer controlled test system for process control and monitoring systems

    International Nuclear Information System (INIS)

    Worster, L.D.

    A minicomputer controlled test system for testing process control and monitoring systems is described. This system, in service for over one year, has demonstrated that computerized control of such testing has a real potential for expanding the scope of the testing, improving accuracy of testing, and significantly reducing the time required to do the testing. The test system is built around a 16-bit minicomputer with 12K of memory. The system programming language is BASIC with the addition of assembly level routines for communication with the peripheral devices. The peripheral devices include a 100 channel scanner, analog-to-digital converter, visual display, and strip printer. (auth)

  18. Neurosurgical operating computerized tomographic scanner system

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi.

    1988-01-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place. (author)

  19. A computerized check-out system for transducers in nuclear power plants

    International Nuclear Information System (INIS)

    Brandt, A.

    1984-01-01

    A computerized system for the acquisition, administration and recording of test data of about 1000 pressure meters (transducers) being collected annually in nuclear power stations is described. The Mobile System is set up by three components - the control pressure device, the intelligent interface and the microcomputer (PDP 11/23, 256 kB) - the whole being assembled on a moveable wagon which allows on site measurement of the transducers. The PDP 11/23, fully integrated in a VT 103 video terminal, connects to the interface via an IEEE-488 bus system. Its keyboard is equipped with operation keys to handle and control the different test phases - uncoupling the transducer from plant operation, linking the transducer to the Mobile System, testing for leaks in the pipe system, recording and correcting the characteristic curve, reinstallation of the transducer in plant operation. Filling and emptying of the pipelines for high pressure measuring is computer controlled as well. As each Mobile System is a stand-alone test device, the number of systems is freely selectable according to environmental conditions (radiative and non-radiative zones, accessability etc.), failure resp. availability considerations and other boundary conditions. Data transport to and from the Stationary System is done via magnetic tape cartridges (256 KB), which may pick-up data of 150 transducers, or online via twisted pair cable connections between the measuring points and the Stationary System. (orig./GL) [de

  20. The ABC's required for establishing a practical computerized plant engineering management data base system

    Science.gov (United States)

    Maiocco, F. R.; Hume, J. P.

    1976-01-01

    A system's approach is outlined in the paper to assist facility and Plant Engineers improve their organization's data management system. The six basic steps identified may appear somewhat simple; however, adequate planning, proper resources, and the involvement of management will determine the success of a computerized facility management data base. Helpful suggestions are noted throughout the paper to insure the development of a practical computerized data management system.

  1. The Initial Development of a Computerized Operator Support System

    Energy Technology Data Exchange (ETDEWEB)

    Roger Lew; Ronald L Boring; Thomas A Ulrich; Ken Thomas

    2014-08-01

    A computerized operator support system (COSS) is a collection of resilient software technologies to assist operators in monitoring overall nuclear power plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast- moving, complex events. A prototype COSS for a chemical volume control system at a nuclear power plant has been developed in order to demonstrate the concept and provide a test bed for further research. The development process identified four underlying elements necessary for the prototype, which consist of a digital alarm system, computer-based procedures, piping and instrumentation diagram system representations, and a recommender module for mitigation actions. An operational prototype resides at the Idaho National Laboratory (INL) using the U.S. Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). Several human-machine interface (HMI) considerations are identified and incorporated in the prototype during this initial round of development.

  2. Evaluation of a new computerized psychometric test battery: Effects of zolpidem and caffeine.

    Science.gov (United States)

    Pilli, Raveendranadh; Naidu, Mur; Pingali, Usharani; Shobha, Jc

    2013-10-01

    To evaluate the effects of centrally active drugs using a new indigenously developed automated psychometric test system and compare the results with that obtained using pencil- and paper-based techniques. The tests were standardized in 24 healthy participants. Reproducibility of the test procedure was evaluated by performing the tests by a single experimenter on two occasions (interday reproducibility). To evaluate the sensitivity of the tests, the effects of zolpidem (5 mg) and caffeine (500 mg) versus placebo were studied in 24 healthy participants in a randomized, double-blind three-way crossover design. Psychometric tests were performed at baseline and at 1, 2, and 3 h after administration of study medication. The effects of zolpidem and caffeine on the psychomotor performance were most pronounced 1 h after administration. At this time, a significant impairment of performance in the simple reaction test (SRT), choice discrimination test (CDT), digit symbol substitution test (DSST), digit vigilance test (DVT), and card sorting test (CST) was observed with zolpidem. In contrast, caffeine showed a significant improvement in performance in CDT and DVT only. The results suggest that the tests of the computerized system are more sensitive and reliable then the pencil and paper tests in detecting the effects of central acting agents and are suitable for use in clinical areas to conduct studies with patients.

  3. Psychometric evaluation of the EORTC computerized adaptive test (CAT) fatigue item pool

    DEFF Research Database (Denmark)

    Petersen, Morten Aa; Giesinger, Johannes M; Holzner, Bernhard

    2013-01-01

    Fatigue is one of the most common symptoms associated with cancer and its treatment. To obtain a more precise and flexible measure of fatigue, the EORTC Quality of Life Group has developed a computerized adaptive test (CAT) measure of fatigue. This is part of an ongoing project developing a CAT...

  4. 45 CFR 310.25 - What conditions apply to acquisitions of Computerized Tribal IV-D Systems?

    Science.gov (United States)

    2010-10-01

    ... FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.25 What conditions apply to... 45 Public Welfare 2 2010-10-01 2010-10-01 false What conditions apply to acquisitions of...

  5. A computerized faculty time-management system in an academic family medicine department.

    Science.gov (United States)

    Daugird, Allen J; Arndt, Jane E; Olson, P Richard

    2003-02-01

    The authors describe the development, implementation, and evaluation of a computerized faculty time-management system (FTMS) in the Department of Family Medicine at the University of North Carolina-Chapel Hill. The FTMS is presented as an integrated set of computerized spreadsheets used annually to allocate faculty time across all mission activities of the department. It was first implemented in 1996 and has been continuously developed since then. An iterative approach has been used to gain consensus among faculty about time resources needed for various tasks of all missions of the department. These time-resource assumptions are used in the computerized system. Faculty time is allocated annually by the department vice chair in negotiation with individual faculty, making sure that the activities planned do not exceed the work time each faculty member has available for the year. During this process, faculty preferences are balanced against department aggregate needs to meet mission commitments and obligations. The authors describe how the computerized FTMS is used for faculty time management and career development, department planning, budget planning, clinical scheduling, and mission cost accounting. They also describe barriers and potential abuses and the challenge of building an organizational culture willing to discuss faculty time openly and committed to developing a system perceived as fair and accurate. The spreadsheet file is available free from the authors for use in other departments.

  6. Computerized tests to evaluate recovery of cognitive function after deep sedation with propofol and remifentanil for colonoscopy.

    Science.gov (United States)

    Borrat, Xavier; Ubre, Marta; Risco, Raquel; Gambús, Pedro L; Pedroso, Angela; Iglesias, Aina; Fernandez-Esparrach, Gloria; Ginés, Àngels; Balust, Jaume; Martínez-Palli, Graciela

    2018-03-27

    The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptors of cognitive function. The purpose of the present study was to evaluate the time course of cognitive function recovery after sedation with propofol and remifentanil. A prospective observational double blind clinical study conducted in 34 young healthy adults undergoing elective outpatient colonoscopy under sedation with the combination of propofol and remifentanil using a target controlled infusion system. Cognitive function was measured using a validated battery of computerized cognitive tests (Cogstate™, Melbourne, Australia) at different predefined times: prior to starting sedation (Tbaseline), and then 10 min (T10), 40 min (T40) and 120 min (T120) after the end of colonoscopy. Tests included the assessment of psychomotor function, attention, visual memory and working memory. All colonoscopies were completed (median time: 26 min) without significant adverse events. Patients received a median total dose of propofol and remifentanil of 149 mg and 98 µg, respectively. Psychomotor function and attention declined at T10 but were back to baseline values at T40 for all patients. The magnitude of psychomotor task reduction was large (d = 0.81) however 100% of patients were recovered at T40. Memory related tasks were not affected 10 min after ending sedation. Cognitive impairment in attention and psychomotor function after propofol and remifentanil sedation was significant and large and could be easily detected by computerized cognitive tests. Even though, patients were fully recovered 40 min after ending the procedure. From a cognitive recovery point of view, larger studies should be undertaken to propose adequate criteria for discharge

  7. Development and Validation of the Computerized Family Relations Test for Children.

    Science.gov (United States)

    Skoczń, Ilona; Cieciuch, Jan; Oud, Johan H L; Welzen, Kai

    2015-01-01

    The aim of the present study was to develop and investigate the psychometric properties of the Computerized Family Relations Test (CFRT) for children. This test assesses the quality of family relationships with the mother and father from a child's perspective. The CFRT consists of six scales relating to control (Restrictiveness and Justice), and support (Affection, Vulnerability, Acknowledgment, and Trust) within the family relationships. CFRT is an innovative approach to the Dutch Nijmegen Family Relations Test (NFRT) developed by Oud and Welzen (1989). The administration of the test has been computerized and graphical representations of female and male silhouettes were included to facilitate the child's parental identification. In total, 404 primary school children, aged 8 to 13 years (M = 11.0; SD = 1.17), took part in this study. The CFRT's reliability was assessed by McDonald's omega coefficients, and ranged from 0.71 to 0.86, except for Vulnerability which achieved the lowest reliability 0.57 for mothers' ratings and 0.56 for fathers' ratings. The test-retest procedure revealed higher stability for the ratings on father-child relationships of 0.71 compared to mother-child relationships of 0.67. Confirmatory factor analysis indicated that a six-factor model provided an adequate fit. Measurement invariance across the children's assessments of the quality of family relationships was achieved. The construct validity of CFRT was assessed by examining differences in the child's ratings of the relationships with the mother and father, the child's gender, and associations of CFRT scales with other variables such as depression, anxiety symptoms, and prosocial behavior.

  8. AUTOMATIC ESTIMATION OF SIZE PARAMETERS USING VERIFIED COMPUTERIZED STEREOANALYSIS

    Directory of Open Access Journals (Sweden)

    Peter R Mouton

    2011-05-01

    Full Text Available State-of-the-art computerized stereology systems combine high-resolution video microscopy and hardwaresoftware integration with stereological methods to assist users in quantifying multidimensional parameters of importance to biomedical research, including volume, surface area, length, number, their variation and spatial distribution. The requirement for constant interactions between a trained, non-expert user and the targeted features of interest currently limits the throughput efficiency of these systems. To address this issue we developed a novel approach for automatic stereological analysis of 2-D images, Verified Computerized Stereoanalysis (VCS. The VCS approach minimizes the need for user interactions with high contrast [high signal-to-noise ratio (S:N] biological objects of interest. Performance testing of the VCS approach confirmed dramatic increases in the efficiency of total object volume (size estimation, without a loss of accuracy or precision compared to conventional computerized stereology. The broad application of high efficiency VCS to high-contrast biological objects on tissue sections could reduce labor costs, enhance hypothesis testing, and accelerate the progress of biomedical research focused on improvements in health and the management of disease.

  9. A toolkit for computerized operating procedure of complex industrial systems with IVI-COM technology

    International Nuclear Information System (INIS)

    Zhou Yangping; Dong Yujie; Huang Xiaojing; Ye Jingliang; Yoshikawa, Hidekazu

    2013-01-01

    A human interface toolkit is proposed to help the user develop computerized operating procedure of complex industrial system such as Nuclear Power Plants (NPPs). Coupled with a friendly graphical interface, this integrated tool includes a database, a procedure editor and a procedure executor. A three layer hierarchy is adopted to express the complexity of operating procedure, which includes mission, process and node. There are 10 kinds of node: entrance, exit, hint, manual input, detector, actuator, data treatment, branch, judgment and plug-in. The computerized operating procedure will sense and actuate the actual industrial systems with the interface based on IVI-COM (Interchangeable Virtual Instrumentation-Component Object Model) technology. A prototype system of this human interface toolkit has been applied to develop a simple computerized operating procedure for a simulated NPP. (author)

  10. Studies and research concerning BNFP: computerized nuclear materials control and accounting system development evaluation report, FY 1978

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, J M; Ehinger, M H; Joseph, C; Madeen, M L

    1978-10-01

    Development work on a computerized system for nuclear materials control and accounting in a nuclear fuel reprocessing plant is described and evaluated. Hardware and software were installed and tested to demonstrate key measurement, measurement control, and accounting requirements at accountability input/output points using natural uranium. The demonstration included a remote data acquisition system which interfaces process and special instrumentation to a cenral processing unit.

  11. Computerized waste-accountability shipping and packaging system

    International Nuclear Information System (INIS)

    Jackson, J.A.; Baston, M. Jr.; DeVer, E.A.

    1981-01-01

    The Waste Accountability, Shipping and Packaging System (WASP) is a real-time computerized system designed and implemented by Mound Facility to meet the stringent packaging and reporting requirements of radioactive waste being shipped to burial sites. The system stores packaging data and inspection results for each unit and prepares all necessary documents at the time of shipment. Shipping data specific for each burial site are automatically prepared on magnetic tape for transmission to the computing center at that site. WASP has enabled Mound Facility to effectively meet the requirements of the burial sites, diminishing the possibility of being rejected from a site because of noncompliance

  12. The importance of proper administration and interpretation of neuropsychological baseline and postconcussion computerized testing.

    Science.gov (United States)

    Moser, Rosemarie Scolaro; Schatz, Philip; Lichtenstein, Jonathan D

    2015-01-01

    Media coverage, litigation, and new legislation have resulted in a heightened awareness of the prevalence of sports concussion in both adult and youth athletes. Baseline and postconcussion testing is now commonly used for the assessment and management of sports-related concussion in schools and in youth sports leagues. With increased use of computerized neurocognitive sports concussion testing, there is a need for standards for proper administration and interpretation. To date, there has been a lack of standardized procedures by which assessments are administered. More specifically, individuals who are not properly trained often interpret test results, and their methods of interpretation vary considerably. The purpose of this article is to outline factors affecting the validity of test results, to provide examples of misuse and misinterpretation of test results, and to communicate the need to administer testing in the most effective and useful manner. An increase in the quality of test administration and application may serve to decrease the prevalence of invalid test results and increase the accuracy and utility of baseline test results if an athlete sustains a concussion. Standards for test use should model the American Psychological Association and Centers for Disease Control and Prevention guidelines, as well as the recent findings of the joint position paper on computerized neuropsychological assessment devices.

  13. Test and evaluation of computerized nuclear material accounting methods. Final report

    International Nuclear Information System (INIS)

    1995-01-01

    In accordance with the definition of a Material Balance Area (MBA) as a well-defined geographical area involving an Integral operation, the building housing the BFS-1 and BFS-1 critical facilities is considered to consist of one MBA. The BFS materials are in the form of small disks clad in stainless steel and each disk with nuclear material has its own serial number. Fissile material disks in the BFS MBA can be located at three key monitoring points: BFS-1 facility, BFS-2 facility and main storage of BFS fissile materials (storage 1). When used in the BFS-1 or BFS-2 critical facilities, the fissile material disks are loaded in tubes (fuel rods) forming critical assembly cores. The following specific features of the BFS MBA should be taken into account for the purpose of computerized accounting of nuclear material: (1) very large number of nuclear material items (about 70,000 fissile material items); and (2) periodically very intensive shuffling of nuclear material items. Requirements for the computerized system are determined by basic objectives of nuclear material accounting: (1) providing accurate information on the identity and location of all items in the BFS material balance area; (2) providing accurate information on location and identity of tamper-indicating devices; (3) tracking nuclear material inventories; (4) issuing periodic reports; (5) assisting with the detection of material gains or losses; (6) providing a history of nuclear material transactions; (7) preventing unauthorized access to the system and data falsification. In August 1995, the prototype computerized accounting system was installed on the BFS facility for trial operation. Information on two nuclear material types was entered into the data base: weapon-grade plutonium metal and 36% enriched uranium dioxide. The total number of the weapon-grade plutonium disks is 12,690 and the total number of the uranium dioxide disks is 1,700

  14. The Development of CPSES Plug-in(CPMP) for APR1400 Computerized Procedure Effective Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Seong, No Kyu; Park, Jin Kyun; Jung, Yeon Sub [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The Computerized Procedure System (CPS) is one of the Man Machine Interface (MMI) resources of the Shin-Kori 3 and 4 nuclear power plants. The CPS is a computerized operator support system that enables operating crew to execute procedures in an accurate and fast manner. The Computerized Procedure (CP) is the XML data file in executable format that can be installed in the Procedure eXecution System (PXS) for execution. The CP contains specific information related to a particular procedure (i.e. LOCA). These computerized procedures such as Alarm Response Procedures (ARP) are separated into individual alarm procedure to maximize function interface between CPS and DCS. E.g. 'Procedure open by alarm list'. The procedure writer's burden to manage many procedures has been increased because of separated procedures. This paper introduces Computerized Procedure System Engineering System (CPSES) plug-in that is computerized procedure management program (CPMP) to reduce procedure writer's burden. This paper introduces the main features of CPMP. CPMP reduces procedure writer's or CPX maintainer's burden. This program is implemented and tested by program design requirement.

  15. Core on-line monitoring and computerized procedures systems

    International Nuclear Information System (INIS)

    Gangloff, W.C.

    1986-01-01

    The availability of operating nuclear power plants has been affected significantly by the difficulty people have in coping with the complexity of the plants and the operating procedures. Two ways to use modern computer technology to ease the burden of coping are discussed in this paper, an on-line core monitoring system with predictive capability and a computerized procedures system using live plant data. These systems reduce human errors by presenting information rather than simply data, using the computer to manipulate the data, but leaving the decisions to the plant operator

  16. 45 CFR 307.10 - Functional requirements for computerized support enforcement systems in operation by October 1...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Functional requirements for computerized support... ENFORCEMENT SYSTEMS § 307.10 Functional requirements for computerized support enforcement systems in operation... necessary to meet Federal Reporting Requirements on a timely basis as prescribed by the Office; (4...

  17. CRRIS: a computerized radiological risk-investigation system

    International Nuclear Information System (INIS)

    Baes, C.F. III; Miller, C.W.

    1981-01-01

    The US Environmental Protection Agency (EPA) is responsible for regulating radioactive airborne effluents in the US. A comprehensive, integrated Computerized Radiological Risk Investigation System (CRRIS) is being developed to support EPA's radiation standards development. This modular system consists primarily of five computer codes and their supporting data bases for estimating environmental transport and radiation doses and risks. Health effects are estimated on the basis of a life-table methodology developed by EPA. CRRIS is designed to provide EPA with a reasonable and flexible way of assessing the risk to man associated with radionuclide releases to the atmosphere

  18. Development and Application of Detection Indices for Measuring Guessing Behaviors and Test-Taking Effort in Computerized Adaptive Testing

    Science.gov (United States)

    Chang, Shu-Ren; Plake, Barbara S.; Kramer, Gene A.; Lien, Shu-Mei

    2011-01-01

    This study examined the amount of time that different ability-level examinees spend on questions they answer correctly or incorrectly across different pretest item blocks presented on a fixed-length, time-restricted computerized adaptive testing (CAT). Results indicate that different ability-level examinees require different amounts of time to…

  19. Development of a computerized nuclear materials control and accounting system for a fuel reprocessing plant

    International Nuclear Information System (INIS)

    Crawford, J.M.; Ehinger, M.H.; Joseph, C.; Madeen, M.L.

    1979-07-01

    A computerized nuclear materials control and accounting system (CNMCAS) for a fuel reprocessing plant is being developed by Allied-General Nuclear Services at the Barnwell Nuclear Fuel Plant. Development work includes on-line demonstration of near real-time measurement, measurement control, accounting, and processing monitoring/process surveillance activities during test process runs using natural uranium. A technique for estimating in-process inventory is also being developed. This paper describes development work performed and planned, plus significant design features required to integrate CNMCAS into an advanced safeguards system

  20. Some performance effects of age and low blood alcohol levels on a computerized neuropsychological test.

    Science.gov (United States)

    1995-02-01

    COGSCREEN is a computerized test battery developed for the Federal Aviation Administration as an airman neuropsychological screening instrument for cognitive functioning. This study explored a multifaceted application of the sensitivity of the batter...

  1. Warning systems in a computerized nursing process for Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Daniela Couto Carvalho Barra

    2014-02-01

    Full Text Available A hybrid study combining technological production and methodological research aiming to establish associations between the data and information that are part of a Computerized Nursing Process according to the ICNP® Version 1.0, indicators of patient safety and quality of care. Based on the guidelines of the Agency for Healthcare Research and Quality and the American Association of Critical Care Nurses for the expansion of warning systems, five warning systems were developed: potential for iatrogenic pneumothorax, potential for care-related infections, potential for suture dehiscence in patients after abdominal or pelvic surgery, potential for loss of vascular access, and potential for endotracheal extubation. The warning systems are a continuous computerized resource of essential situations that promote patient safety and enable the construction of a way to stimulate clinical reasoning and support clinical decision making of nurses in intensive care.

  2. Quantitative inspection by computerized tomography

    International Nuclear Information System (INIS)

    Lopes, R.T.; Assis, J.T. de; Jesus, E.F.O. de

    1989-01-01

    The computerized Tomography (CT) is a method of nondestructive testing, that furnish quantitative information, that permit the detection and accurate localization of defects, internal dimension measurement, and, measurement and chart of the density distribution. The CT technology is much versatile, not presenting restriction in relation to form, size or composition of the object. A tomographic system, projected and constructed in our laboratory is presented. The applications and limitation of this system, illustrated by tomographyc images, are shown. (V.R.B.)

  3. Assessment of Selective Attention with CSCWT (Computerized Stroop Color-Word Test) among Children and Adults

    Science.gov (United States)

    Afsaneh, Zarghi; Alireza, Zali; Mehdi, Tehranidost; Farzad, Ashrafi; Reza, Zarindast Mohammad; Mehdi, Moazzezi; Mojtaba, Khodadadi Seyed

    2012-01-01

    The SCWT (Stroop Color-Word Test) is a quick and frequently used measure for assessing selective attention and cognitive flexibility. This study determines age, sex and education level influence on attention and cognitive flexibility by CSCWT (Computerized Stroop Color-Word Test) among healthy Iranian children and adults. There were 78 healthy…

  4. Computerized reactor monitor and control for research reactors

    International Nuclear Information System (INIS)

    Buerger, L.; Vegh, E.

    1981-09-01

    The computerized process control system developed in the Central Research Institute for Physics, Budapest, Hungary, is described together with its special applications at research reactors. The nuclear power of the Hungarian research reactor is controlled by this computerized system, too, while in Lybia many interesting reactor-hpysical calculations are built into the computerized monitor system. (author)

  5. Using computerized provider order entry to enforce documentation of tests with pending results at hospital discharge.

    Science.gov (United States)

    Cadwallader, J; Asirwa, C; Li, X; Kesterson, J; Tierney, W M; Were, M C

    2012-01-01

    Small numbers of tests with pending results are documented in hospital discharge summaries leading to breakdown in communication and medical errors due to inadequate followup. Evaluate effect of using a computerized provider order entry (CPOE) system to enforce documentation of tests with pending results into hospital discharge summaries. We assessed the percent of all tests with pending results and those with actionable results that were documented before (n = 182 discharges) and after (n = 203 discharges) implementing the CPOE-enforcement tool. We also surveyed providers (n = 52) about the enforcement functionality. Documentation of all tests with pending results improved from 12% (87/701 tests) before to 22% (178/812 tests) (p = 0.02) after implementation. Documentation of tests with eventual actionable results increased from 0% (0/24) to 50% (14/28)(ppending results into discharge summaries significantly increased documentation rates, especially of actionable tests. However, gaps in documentation still exist.

  6. A comparison of paper-and-pencil and computerized forms of Line Orientation and Enhanced Cued Recall Tests.

    Science.gov (United States)

    Aşkar, Petek; Altun, Arif; Cangöz, Banu; Cevik, Vildan; Kaya, Galip; Türksoy, Hasan

    2012-04-01

    The purpose of this study was to assess whether a computerized battery of neuropsychological tests could produce similar results as the conventional forms. Comparisons on 77 volunteer undergraduates were carried out with two neuropsychological tests: Line Orientation Test and Enhanced Cued Recall Test. Firstly, students were assigned randomly across the test medium (paper-and-pencil versus computerized). Secondly, the groups were given the same test in the other medium after a 30-day interval between tests. Results showed that the Enhanced Cued Recall Test-Computer-based did not correlate with the Enhanced Cued Recall Test-Paper-and-pencil results. Line Orientation Test-Computer-based scores, on the other hand, did correlate significantly with the Line Orientation Test-Paper-and-pencil version. In both tests, scores were higher on paper-and-pencil tests compared to computer-based tests. Total score difference between modalities was statistically significant for both Enhanced Cued Recall Tests and for the Line Orientation Test. In both computer-based tests, it took less time for participants to complete the tests.

  7. A study on Requirements of Data Base Translator for APR1400 Computerized Procedure System at Shin-Hanul unit 1 and 2

    International Nuclear Information System (INIS)

    Seong, Nokyu; Lee, Sungjin

    2015-01-01

    The CPS is one of the Man Machine Interface (MMI) resources and the CPS can directly display plant graphic objects which are in the Digital Control System (DCS). And the CPS can send a request to DCS to provide DCS screen which is called step support display through DCS link button on a computerized procedure. The procedure writers can insert DCS graphic information to computerized procedure through data base which is provided by CPS Editing System (CPSES). The data base which is provided by CPSES conforms to the naming rule of DCS graphic objects. The naming rule of DCS graphic objects is defined by vendor thus status of DCS graphic objects which are in computerized procedure at Shin-Kori plant cannot be displayed on CPS at Shin-Hanul plant. To use computerized procedure which is written by other plant procedure writer, DCS graphic objects shall be translated by its plant data base. This paper introduces requirements of data base translator to reduce translation and re-inserting graphic objects burden. This paper introduces the requirements of data base translator of CPSES for APR1400 CPS at Shin-Hanul unit 1 and 2. The translator algorithms shall be tested to update data base of CPSES effectively. The prototype of translator is implemented and is being tested using real plant DB. This translator can be applied to Shin- Hanul unit1 and 2 through software V and V

  8. A study on Requirements of Data Base Translator for APR1400 Computerized Procedure System at Shin-Hanul unit 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Nokyu; Lee, Sungjin [KHNP, Daejeon (Korea, Republic of)

    2015-05-15

    The CPS is one of the Man Machine Interface (MMI) resources and the CPS can directly display plant graphic objects which are in the Digital Control System (DCS). And the CPS can send a request to DCS to provide DCS screen which is called step support display through DCS link button on a computerized procedure. The procedure writers can insert DCS graphic information to computerized procedure through data base which is provided by CPS Editing System (CPSES). The data base which is provided by CPSES conforms to the naming rule of DCS graphic objects. The naming rule of DCS graphic objects is defined by vendor thus status of DCS graphic objects which are in computerized procedure at Shin-Kori plant cannot be displayed on CPS at Shin-Hanul plant. To use computerized procedure which is written by other plant procedure writer, DCS graphic objects shall be translated by its plant data base. This paper introduces requirements of data base translator to reduce translation and re-inserting graphic objects burden. This paper introduces the requirements of data base translator of CPSES for APR1400 CPS at Shin-Hanul unit 1 and 2. The translator algorithms shall be tested to update data base of CPSES effectively. The prototype of translator is implemented and is being tested using real plant DB. This translator can be applied to Shin- Hanul unit1 and 2 through software V and V.

  9. Strategies for Controlling Item Exposure in Computerized Adaptive Testing with the Generalized Partial Credit Model

    Science.gov (United States)

    Davis, Laurie Laughlin

    2004-01-01

    Choosing a strategy for controlling item exposure has become an integral part of test development for computerized adaptive testing (CAT). This study investigated the performance of six procedures for controlling item exposure in a series of simulated CATs under the generalized partial credit model. In addition to a no-exposure control baseline…

  10. Development of a computerized nuclear materials control and accounting system for a fuel reprocessing plant

    International Nuclear Information System (INIS)

    Crawford, J.M.; Ehinger, M.H.; Joseph, C.; Madeen, M.L.

    1979-01-01

    A computerized nuclear materials control and accounting system (CNMCAS) for a fuel reprocessing plant is being developed by Allied-General Nuclear Services at the Barnwell Nuclear Fuel Plant. Development work includes on-line demonstration of near real-time measurement, measurement control, accounting, and processing monitoring/process surveillance activities during test process runs using natural uranium. A technique for estimating in-process inventory is also being developed. This paper describes development work performed and planned, plus significant design features required to integrate CNMCAS into an advanced safeguards system. 2 refs

  11. Improvements in Logic Diagram of Computerized Procedure System of APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sungkweon; Seong, Nokyu [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The Computerized Procedure System (CPS) has been improved since it is installed in Shin-Kori 3 and 4 Nuclear Power Plants. It is one of operating support systems of digital Main Control Room (MCR) and provides many functions to operators in executing the procedure. CPS can effectively remove the human errors by supporting the procedure flow and logic diagram. This paper describes the logic diagram of CPS of reference power plant and shows the improved logic diagram of CPS of Shin-Kori unit 5 and 6. This paper describes the current logic diagram of CPS and suggests improved design for logic diagram. The improved logic diagram shall be validated through human factors engineering verification and validation. The improved design will help operators execute the computerized procedure fast and remove the human error.

  12. Development of a computerized system for performance monitoring and diagnostics in nuclear power plants

    International Nuclear Information System (INIS)

    Chou, G.H.; Chao, H.J.

    1995-01-01

    An on-line computerized system for thermal performance monitoring and diagnostics has been developed at the Institute of Nuclear Energy Research (INER). It was the product of the ChinShan plant performance Monitoring, Analysis and Diagnostics Expert System (CS-MADES) project sponsored by Taiwan Power Company (TPC). The system can carry out turbine performance monitoring and analysis during normal operation, and yield diagnostic results of component degradation after finding out the missing generation problems. Three subsystems were generated to support the whole system framework. They are Test Data Processing Subsystem (TDPS), On-line Monitoring and Analysis Subsystem (OMAS), and Thermal Performance Diagnostics Expert System (TPDES). Some visible benefits have been gained so far through the prototype system installed at the Chinshan nuclear power station

  13. Wilderness Management... A Computerized System for Summarizing Permit Information

    Science.gov (United States)

    Gary H. Elsner

    1972-01-01

    Permits were first needed for visits to wilderness areas in California during summer 1971. A computerized system for analyzing these permits and summarizing information from them has been developed. It produces four types of summary tables: point-of-origin of visitors; daily variation in total number of persons present; variations in group size; and variations in...

  14. Development and validation of the Computerized Family Relation Test (CFRT for children

    Directory of Open Access Journals (Sweden)

    Ilona eSkoczeń

    2015-11-01

    Full Text Available The aim of the present study was to develop and investigate the psychometric properties of the Computerized Family Relations Test (CFRT for children. This test assesses the quality of family relationships with the mother and father from a child’s perspective. The CFRT consists of six scales relating to control (Restrictiveness and Justice, and support (Affection, Vulnerability, Acknowledgement, and Trust within the family relationships. CFRT is an innovative approach to the Dutch Nijmegen Family Relations Test (NFRT developed by Oud and Welzen (1989. The administration of the test has been computerized and graphical representations of female and male silhouettes were included to facilitate the child’s parental identification. In total, 404 primary school children, aged 8 to 13 years (M = 11.0; SD = 1.17, took part in this study. The CFRT’s reliability was assessed by McDonald’s omega coefficients, and ranged from .71 to .86, except for Vulnerability which achieved the lowest reliability.57 for mothers’ ratings and .56 for fathers’ ratings. The test-retest procedure revealed higher stability for the ratings on father-child relationships of .71 compared to mother-child relationships of .67. Confirmatory factor analysis indicated that a six-factor model provided an adequate fit. Measurement invariance across the children’s assessments of the quality of family relationships was achieved. The construct validity of CFRT was assessed by examining differences in the child’s ratings of the relationships with the mother and father, the child’s gender, and associations of CFRT scales with other variables such as depression, anxiety symptoms, and prosocial behavior.

  15. 45 CFR 310.40 - What requirements apply for accessing systems and records for monitoring Computerized Tribal IV-D...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false What requirements apply for accessing systems and records for monitoring Computerized Tribal IV-D Systems and Office Automation? 310.40 Section 310.40... COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Accountability and Monitoring Procedures for...

  16. Detection of Acute and Long-Term Effects of Concussion: Dual-Task Gait Balance Control Versus Computerized Neurocognitive Test.

    Science.gov (United States)

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2018-02-16

    To examine the acute (within 72h of injury) and long-term (2mo postinjury) independent associations between objective dual-task gait balance and neurocognitive measurements among adolescents and young adults with a concussion and matched controls. Longitudinal case-control. Motion analysis laboratory. A total of 95 participants completed the study: 51 who sustained a concussion (mean age, 17.5±3.3y; 71% men) and 44 controls (mean age, 17.7±2.9y; 72% men). Participants who sustained a concussion underwent a dual-task gait analysis and computerized neurocognitive testing within 72 hours of injury and again 2 months later. Uninjured controls also completed the same test protocol in similar time increments. Not applicable. We compared dual-task gait balance control and computerized neurocognitive test performance between groups using independent samples t tests. Multivariable binary logistic regression models were then constructed for each testing time to determine the association between group membership (concussion vs control), dual-task gait balance control, and neurocognitive function. Medial-lateral center-of-mass displacement during dual-task gait was independently associated with group membership at the initial test (adjusted odds ratio [aOR], 2.432; 95% confidence interval [CI], 1.269-4.661) and 2-month follow-up test (aOR, 1.817; 95% CI, 1.014-3.256) tests. Visual memory composite scores were significantly associated with group membership at the initial hour postinjury time point (aOR, .953; 95% CI, .833-.998). However, the combination of computerized neurocognitive test variables did not predict dual-task gait balance control for participants with concussion, and no single neurocognitive variable was associated with dual-task gait balance control at either testing time. Dual-task assessments concurrently evaluating gait and cognitive performance may allow for the detection of persistent deficits beyond those detected by computerized neurocognitive deficits

  17. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  18. Improved Design of Crew Operation in Computerized Procedure System of APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Seong, No Kyu; Jung, Yeon Sub; Sung, Chan Ho [KHNP, Daejeon (Korea, Republic of)

    2016-05-15

    The operators perform the paper-based procedures in analog-based conventional main control room (MCR) depending on only communications between operators except a procedure controller such as a Shift Supervisor (SS), however in digital-based MCR the operators can confirm the procedures simultaneously in own console when the procedure controller of computerized procedure (CP) opens the CP. The synchronization and a synchronization function between procedure controller and other operators has to be considered to support the function of crew operation. This paper suggests the improved design of crew operation in computerized procedure system of APR1400. This paper suggests the improved design of APR1400 CPS. These improvements can help operators perform the crew procedures more efficiently. And they reduce a burden of communication and misunderstanding of computerized procedures. These improvements can be applied to CPS after human factors engineering verification and validation.

  19. Study on computerized presentation of emergency procedures of a nuclear plant (step 2). The guidelines of the prototype of the computerized procedure presentation system

    International Nuclear Information System (INIS)

    Niwa, Yuji; Hollnagel, E.; Iwaki, Toshio.

    1995-01-01

    New methods of information presentation and interface design are changing the working conditions in the modern Nuclear Power Plant (NPP) control room. One area receiving considerable attention is that of Emergency Operating Procedures (EOPs), which plays an essential role in NPPs. Conventionally procedures are presented in a hard copy form. However developments in information technology have offered new opportunities for the computerization of such procedures. Consideration for the first stage of computerization should be focused upon the presentation of procedures. The specification of the computerized presentation of procedures is discussed with respect to the issues which were central to the project: navigation through procedures; formatting and presentation of procedures; and process monitoring. Issues that would be included in more advanced systems, such as help and explanation facilities features, and process linking, are also discussed. This paper deals with the specific design guidelines that were implemented for the computerization of procedure presentation. Issues of principal concern that were identified from this experience are highlighted, such as the relationship between procedure presentation and format; the registration of progress through a procedure; compensation for the limitations of computer displays versus printed documents; and the way in which the added capabilities of computerized presentation can be generally utilized in the operators' working environment. (author)

  20. A Method for the Comparison of Item Selection Rules in Computerized Adaptive Testing

    Science.gov (United States)

    Barrada, Juan Ramon; Olea, Julio; Ponsoda, Vicente; Abad, Francisco Jose

    2010-01-01

    In a typical study comparing the relative efficiency of two item selection rules in computerized adaptive testing, the common result is that they simultaneously differ in accuracy and security, making it difficult to reach a conclusion on which is the more appropriate rule. This study proposes a strategy to conduct a global comparison of two or…

  1. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  2. Mixed results in the safety performance of computerized physician order entry.

    Science.gov (United States)

    Metzger, Jane; Welebob, Emily; Bates, David W; Lipsitz, Stuart; Classen, David C

    2010-04-01

    Computerized physician order entry is a required feature for hospitals seeking to demonstrate meaningful use of electronic medical record systems and qualify for federal financial incentives. A national sample of sixty-two hospitals voluntarily used a simulation tool designed to assess how well safety decision support worked when applied to medication orders in computerized order entry. The simulation detected only 53 percent of the medication orders that would have resulted in fatalities and 10-82 percent of the test orders that would have caused serious adverse drug events. It is important to ascertain whether actual implementations of computerized physician order entry are achieving goals such as improved patient safety.

  3. Incremental Validity of New Computerized Aptitude Tests for Predicting Training Performance in Nine Navy Technical Schools

    National Research Council Canada - National Science Library

    Wolfe, John H; Larson, Gerald E; Alderton, David L

    2006-01-01

    During their second week of basic training, 4,989 Navy recruits assigned to one of nine technical training schools were administered a battery of six experimental computerized aptitude tests measuring four constructs...

  4. Formal Verification of Computerized Procedure with Colored Petri Nets

    International Nuclear Information System (INIS)

    Kim, Yun Goo; Shin, Yeong Cheol

    2008-01-01

    Computerized Procedure System (CPS) supports nuclear power plant operators in performing operating procedures which are instructions to guide in monitoring, decision making and controlling nuclear power plants. Computerized Procedure (CP) should be loaded to CPS. Due to its execution characteristic, computerized procedure acts like a software in CPS. For example, procedure flows are determined by operator evaluation and computerized procedure logic which are pre-defined. So the verification of Computerized Procedure logic and execution flow is needed before computerized procedures are installed in the system. Formal verification methods are proposed and the modeling of operating procedures with Coloured Petri Nets(CP-nets) is presented

  5. E/Z MAS: An easy-to-use computerized materials control and accountability system

    International Nuclear Information System (INIS)

    Anderson, L.K.; Boor, M.G.; Hurford, J.M.; Landry, R.P.; Martinez, B.J.; Solem, A.M.; Whiteson, R.; Zardecki, A.

    1998-01-01

    Nuclear facilities that handle and process nuclear materials are required to track their nuclear holdings and to keep adequate records that manage and control the inventory of those holdings. The complexity of a system that does this job is directly proportional to the complexity of the facility's operations. This paper describes an approach to computerized materials protection, control, and accountability (MPC and A) that was introduced by Los Alamos National Laboratory (LANL) in the fall of 1997. This new system, E/Z MAS, is the latest addition to the LANL suite of computerized MPC and A tools, which also includes the CoreMAS system. E/Z MAS was initially designed to address the needs of those facilities that have small to modest MPC and A needs but has been expanded to provide full functionality for any facility. The system name, E/Z MAS, reflects the system's easy-to-use characteristics, which include ease of installation and ease of software maintenance. Both CoreMAS and E/Z MAS have been provided to facilities in the Former Soviet Union to assist them in implementing a computerized MPC and A system that meets their needs. In this paper the authors will address the functionality of CoreMAS and E/Z MAS, and an argument in favor of intranet-based material control and accountability will be advanced

  6. simulate_CAT: A Computer Program for Post-Hoc Simulation for Computerized Adaptive Testing

    Directory of Open Access Journals (Sweden)

    İlker Kalender

    2015-06-01

    Full Text Available This paper presents a computer software developed by the author. The software conducts post-hoc simulations for computerized adaptive testing based on real responses of examinees to paper and pencil tests under different parameters that can be defined by user. In this paper, short information is given about post-hoc simulations. After that, the working principle of the software is provided and a sample simulation with required input files is shown. And last, output files are described

  7. Computerized low-level waste assay system operation manual

    International Nuclear Information System (INIS)

    Jones, D.F.; Cowder, L.R.; Martin, E.R.

    1976-01-01

    An operation and maintenance manual for the computerized low-level waste box counter is presented, which describes routine assay techniques as well as theory of operation treated in sufficient depth so that an experienced assayist can make nonroutine assays. In addition, complete system schematics are included, along with a complete circuit description to facilitate not only maintenance and troubleshooting, but also reproduction of the instrument if desired. Complete software system descriptions are included so far as calculational algorithms are concerned, although detailed instruction listings would have to be obtained from Group R-1 at LASL in order to make machine-language code changes

  8. A Comparison of Validity Rates between Paper-and-Pencil and Computerized Testing with the MMPI-2

    Science.gov (United States)

    Blazek, Nicole L.; Forbey, Johnathan D.

    2011-01-01

    Although the use of computerized testing in psychopathology assessment has increased in recent years, limited research has examined the impact of this format in terms of potential differences in test validity rates. The current study explores potential differences in the rates of valid and invalid Minnesota Multiphasic Personality Inventory--2…

  9. Computerized real-time materials accountability system for safeguards material control

    International Nuclear Information System (INIS)

    Spencer, W.F.; Affel, R.G.; Austin, H.C.; Nichols, J.P.; Stoutt, B.H.; Wachter, J.W.

    1975-01-01

    A real-time, computer-based system is described which provides safeguards material control at the Oak Ridge National Laboratory. Originally installed in 1972 to provide computerized real-time fissile materials accountability for criticality control purposes, the system has been expanded to provide accountability of all source and nuclear materials (SNM) and to utilize the on-line inventory files in support of the Laboratory physical protection and surveillance procedures. (auth)

  10. The industrial computerized tomography applied to the rock analysis

    International Nuclear Information System (INIS)

    Tetzner, Guaraciaba de Campos

    2008-01-01

    This work is a study of the possibilities of the technical applications of Computerized Tomography (CT) by using a device developed in the Radiation Technology Center (CTR), Institute for Energy and Nuclear Research (IPEN-CNEN/SP). The equipment consists of a gamma radiation source ( 60 Co), a scintillation detector of sodium iodide doped with thallium (NaI (Tl)), a mechanical system to move the object (rotation and translation) and a computer system. This operating system has been designed and developed by the CTR-IPEN-CNEN/SP team using national resources and technology. The first validation test of the equipment was carried out using a cylindrical sample of polypropylene (phantom) with two cylindrical cavities (holes) of 5 x 25 cm (diameter and length). In these tests, the holes were filled with materials of different density (air, oil and metal), whose attenuation coefficients are well known. The goal of this first test was to assess the response quality of the equipment. The present report is a study comparing computerized tomography equipment CTR-IPEN-CNEN/SP which uses a source of gamma radiation ( 60 Co) and other equipment provided by the Department of Geosciences in the University of Texas (CTUT), which uses an X-ray source (450 kV and 3.2 mA). As a result, the images obtained and the comprehensive study of the usefulness of the equipment developed here strengthened the proposition that the development of industrial computerized tomography is an important step toward consolidating the national technology. (author)

  11. 45 CFR 310.35 - Under what circumstances would emergency FFP be available for Computerized Tribal IV-D Systems?

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Under what circumstances would emergency FFP be... AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.35 Under what circumstances would emergency FFP be available for Computerized Tribal IV-D Systems? (a...

  12. Implementing of the nuclear materials accounting and control computerized system at JINR

    International Nuclear Information System (INIS)

    Dobryanskij, V.M.; Kalyakin, N.N.; Koltin, G.P.; Samojlov, V.N.; Cheker, A.V.; Shestakov, B.A.

    2000-01-01

    The results of the development of the computerized nuclear materials accounting system at the Joint Institute for Nuclear Research (JINR) are submitted. This work was carried out under Russian-American Nuclear Materials Protection, Control and Accounting (MPCandA) Program. The System was implemented at the Institute, it was attested to work with sensitive information. The computerized information nuclear materials accounting and control system, named MTIS (Materials Tracking Information System), is intended for the automated accounting of the nuclear materials used in JINR, tracking their moving, changes of their inventory amounts, preparation of the required documentation, and also for information support of the measures spent in the JINR on MPCandA program. MTIS can prepare reports for federal level and can also generate data to be reported for internal purposes. MTIS includes as one of the subsystems a program module to prepare reporting information to the Federal Information System (FIS). The system MTIS provides control of access to the database (DB), protection of the information against the non-authorized access, division of the data into the sensitive and non-sensitive data. (author)

  13. The computerized OMAHA system in microsoft office excel.

    Science.gov (United States)

    Lai, Xiaobin; Wong, Frances K Y; Zhang, Peiqiang; Leung, Carenx W Y; Lee, Lai H; Wong, Jessica S Y; Lo, Yim F; Ching, Shirley S Y

    2014-01-01

    The OMAHA System was adopted as the documentation system in an interventional study. To systematically record client care and facilitate data analysis, two Office Excel files were developed. The first Excel file (File A) was designed to record problems, care procedure, and outcomes for individual clients according to the OMAHA System. It was used by the intervention nurses in the study. The second Excel file (File B) was the summary of all clients that had been automatically extracted from File A. Data in File B can be analyzed directly in Excel or imported in PASW for further analysis. Both files have four parts to record basic information and the three parts of the OMAHA System. The computerized OMAHA System simplified the documentation procedure and facilitated the management and analysis of data.

  14. Computerized provider order entry in the clinical laboratory

    Science.gov (United States)

    Baron, Jason M.; Dighe, Anand S.

    2011-01-01

    Clinicians have traditionally ordered laboratory tests using paper-based orders and requisitions. However, paper orders are becoming increasingly incompatible with the complexities, challenges, and resource constraints of our modern healthcare systems and are being replaced by electronic order entry systems. Electronic systems that allow direct provider input of diagnostic testing or medication orders into a computer system are known as Computerized Provider Order Entry (CPOE) systems. Adoption of laboratory CPOE systems may offer institutions many benefits, including reduced test turnaround time, improved test utilization, and better adherence to practice guidelines. In this review, we outline the functionality of various CPOE implementations, review the reported benefits, and discuss strategies for using CPOE to improve the test ordering process. Further, we discuss barriers to the implementation of CPOE systems that have prevented their more widespread adoption. PMID:21886891

  15. Computerized provider order entry in the clinical laboratory

    Directory of Open Access Journals (Sweden)

    Jason M Baron

    2011-01-01

    Full Text Available Clinicians have traditionally ordered laboratory tests using paper-based orders and requisitions. However, paper orders are becoming increasingly incompatible with the complexities, challenges, and resource constraints of our modern healthcare systems and are being replaced by electronic order entry systems. Electronic systems that allow direct provider input of diagnostic testing or medication orders into a computer system are known as Computerized Provider Order Entry (CPOE systems. Adoption of laboratory CPOE systems may offer institutions many benefits, including reduced test turnaround time, improved test utilization, and better adherence to practice guidelines. In this review, we outline the functionality of various CPOE implementations, review the reported benefits, and discuss strategies for using CPOE to improve the test ordering process. Further, we discuss barriers to the implementation of CPOE systems that have prevented their more widespread adoption.

  16. Computerized industrial tomography

    International Nuclear Information System (INIS)

    Ashraf, M.M.

    1999-01-01

    Computerized Tomographic (CT) has been used for a number of applications in the field of medicine and industry. For the last couple of years, the technique has been applied for the material characterization and detection of defects and flaws inside the industrial components of nuclear, aerospace and missile industries. A CT scanner of first generation was developed at the institute. The scanner has been used to demonstrate couple of applications of CT in the field of non destructive testing of materials. The data acquired by placing the test objects at various angles and scanning the object through a source detector assembly has been processed on a Pentium computer for image reconstruction using a filtered back projection method. The technique has been developed which can be modified and improved to study various other applications in materials science and a modern computerized tomographic facility can be established. (author)

  17. Carolina Power and Light Company's computerized Radiological Information Management System

    International Nuclear Information System (INIS)

    Meyer, B.A.

    1987-01-01

    Carolina Power and Lignt Company has recently implement a new version of their computerized Radiological Information management System. The new version was programmed in-house and is run on the Company's mainframe computers. In addition to providing radiation worker dose histories and current dose updates, the system provides real-time access control for all three of the Company's nuclear plants such as respirator and survey equipment control and inventory, TLD QC records, and many other functions

  18. ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Huang, S.C.; Kuhl, D.E.

    1977-01-01

    The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems

  19. Computerized operator support system for the JMTR: ARGUS

    International Nuclear Information System (INIS)

    Oyamada, R.; Yamamoto, K.; Ishii, Y.; Sekine, N.; Nemoto, N.

    1988-01-01

    ARGUS is computerized operator support system developed for the JMTR Function keybords, alphanumic keybords, and colour display terminals serve as comminication interface between ARGUS and operating personnel. ARGUS serves the following purposes; 1) data logging, 2) early abnormality detection, 3) presenting relevant and concentrated information to the operators to support their accurate judgment in case of abnormality occurrence, 4) save of time-historical data for diagnostics, and 5) data base necessary for JMTR operation and maintenance. ARGUS has been implemented on a VAX-11/750 with mos memories of 7.25 MB. (author)

  20. Computer-based test system for the Tactical Airfield Attack Munition (TAAM) safing, arming, and fuzing system

    International Nuclear Information System (INIS)

    Warhus, J.; Castleton, R.; Lanning, S.

    1981-12-01

    Testing and quality assurance of large numbers of firing systems are an essential part of the development of the Tactical Airfield Attack Munition (TAAM). A computerized test and data acquisition system has been developed to make the testing and quality assurance workload manageable. The system hardware utilizes an LSI-11/23 computer, a Tektronix 7612 transient digitizer, and various other programmable instruments and power supplies. The system is capable of measuring and analyzing mechanical shock and fireset transient waveforms, automating testing sequences, and making records and comparisons of the test results. The system architecture is flexible for general purpose firing system development work

  1. Ten years experience with a large computerized TLD-personnel monitoring system

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1986-01-01

    It is now ten years since our Institute for Radiation Protection has fully replaced its filmdosimetry service by a computerized automated TLD system. Presently more than 13000 radiation workers are monthly monitored by three automated TLD readers linked to the computer center. The paper describes system hardware and software and experience gained in long-term routine operation. In particular the introduction of the new ICRU quantities for personnel dosimetry in the existing TLD system is discussed. (Author)

  2. COST ANALYSIS OF ALTERNATIVE COMPUTERIZED SYSTEMS FOR THE MARKETING AND DISTRIBUTION OF MULTIPLE FOOD COMMODITIES

    OpenAIRE

    Epperson, James E.; Helmreich, D.P.; Moon, Leonard C.; Carley, Dale H.; Huang, Chung L.; Fletcher, Stanley M.

    1981-01-01

    The authors make cost comparisons among alternative computerized marketing systems. The systems described could encompass any number of commodities and stages of distribution involving cash and/or futures transactions.

  3. Safety assessment of computerized control and protection systems. Report of a technical committee meeting held in Vienna, 12-16 October 1992

    International Nuclear Information System (INIS)

    1994-12-01

    In developing the views expressed in this document, papers were presented by delegates from Member States. A total of 6 papers were presented in all on topics ranging from applications of computerized control and protection systems in older plants and in new advanced reactors to methods for improving software reliability. In addition two informal presentations were provided by a vendor and a licensing authority. These presentations provided valuable insights into the application of computerized control and protection systems and into the concern of software reliability with proposals for diverse 'backup' systems of different types. This was supplemented by utility and vendor presentations on system designs. Following the presentations, three working groups were formed to produce their views on the licensing of software based safety systems on reliability models and techniques for assessment of computerized safety systems, and on systems considered for computerized upgrading (need, criteria, approach, pitfalls and benefits). This document represents these collected views with the papers presented attached as an annex. Refs, figs and tabs

  4. Safety-technical comparison of a hard-wired dynamic reactor protection system with a computerized alternative. Pt. 2

    International Nuclear Information System (INIS)

    Buettner, W.E.

    1978-03-01

    The investigation presented here compares a conventional hard-wired dynamic reactor protection system with a computerized alternative. For both systems the spurious trip probability is determined, i.e. the probability of a false release of one or more protection actions due to failures. The mean unavailability is also determined for those not distinctly safety-oriented protection actions of the computerized protection system which are released via the open circuit current principle. This is because system breakdowns prevent the release of those protection actions in case of demand. The advantages and disadvantages of either type of system are viewed against each other. (orig.) [de

  5. Computerized planning system for nuclear power plant evaluation

    International Nuclear Information System (INIS)

    Bonczek, R.H.; Holsapple, C.W.; Whinston, A.B.

    1976-01-01

    A computerized system is described for information storage and query processing adapted to complex socio-technological issues. The system is referred to as GPLAN (Generalized Planning System) and can accommodate both qualitative (verbal) and quantitative data. The issue illustrated is the construction of a nuclear power plant, and involves interdisciplinary research and planning. The system's outstanding features are the use of the network variety of data base, the selective retrieval of any configuration of data from a particular network structure, automatic execution of any desired application program from a standard or special library of applications, user interface with a data base and applications by submitting English-like, non-procedural queries, and generality which allows tailoring to specific applications and provides a basis for integration of planning and research activities. The system is general and can be used for a wide variety of socio-technological issues which involve complex data relationships

  6. Conceptualising computerized adaptive testing for measurement of latent variables associated with physical objects

    International Nuclear Information System (INIS)

    Camargo, F R; Henson, B

    2015-01-01

    The notion of that more or less of a physical feature affects in different degrees the users' impression with regard to an underlying attribute of a product has frequently been applied in affective engineering. However, those attributes exist only as a premise that cannot directly be measured and, therefore, inferences based on their assessment are error-prone. To establish and improve measurement of latent attributes it is presented in this paper the concept of a stochastic framework using the Rasch model for a wide range of independent variables referred to as an item bank. Based on an item bank, computerized adaptive testing (CAT) can be developed. A CAT system can converge into a sequence of items bracketing to convey information at a user's particular endorsement level. It is through item banking and CAT that the financial benefits of using the Rasch model in affective engineering can be realised

  7. Reduced Clostridium difficile Tests and Laboratory-Identified Events With a Computerized Clinical Decision Support Tool and Financial Incentive.

    Science.gov (United States)

    Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B

    2018-06-01

    We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.

  8. Computerized scoring algorithms for the Autobiographical Memory Test.

    Science.gov (United States)

    Takano, Keisuke; Gutenbrunner, Charlotte; Martens, Kris; Salmon, Karen; Raes, Filip

    2018-02-01

    Reduced specificity of autobiographical memories is a hallmark of depressive cognition. Autobiographical memory (AM) specificity is typically measured by the Autobiographical Memory Test (AMT), in which respondents are asked to describe personal memories in response to emotional cue words. Due to this free descriptive responding format, the AMT relies on experts' hand scoring for subsequent statistical analyses. This manual coding potentially impedes research activities in big data analytics such as large epidemiological studies. Here, we propose computerized algorithms to automatically score AM specificity for the Dutch (adult participants) and English (youth participants) versions of the AMT by using natural language processing and machine learning techniques. The algorithms showed reliable performances in discriminating specific and nonspecific (e.g., overgeneralized) autobiographical memories in independent testing data sets (area under the receiver operating characteristic curve > .90). Furthermore, outcome values of the algorithms (i.e., decision values of support vector machines) showed a gradient across similar (e.g., specific and extended memories) and different (e.g., specific memory and semantic associates) categories of AMT responses, suggesting that, for both adults and youth, the algorithms well capture the extent to which a memory has features of specific memories. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  9. ANAPPRES: An expert system for interference well-test analysis

    Energy Technology Data Exchange (ETDEWEB)

    Arellano, V.M.; Iglesias, E.R.; Arellano, J.; Schwarzblat, M.

    1988-01-01

    We present ANAPPRES V1.0, the first version of a computerized expert system capable of analyzing constant- and variable-flowrate interference tests, in which there is one active well and an arbitrary number of observation wells, in liquid-saturated homogeneous reservoirs. ANAPPRES successfully couples mathematical models, optimization techniques, heuristic knowledge and computerized graphics, a combination not often found in published expert systems. Its main advantages are that it is user friendly, requires essentially no experience on the part of the analyst, eliminates subjectivity associated with earlier techniques of analysis, can handle complex cases and large data sets, completes the analysis of even the most complex cases (including plotting the results) in one run, and is significantly faster than a human expert.

  10. A Method of Retrospective Computerized System Validation for Drug Manufacturing Software Considering Modifications

    Science.gov (United States)

    Takahashi, Masakazu; Fukue, Yoshinori

    This paper proposes a Retrospective Computerized System Validation (RCSV) method for Drug Manufacturing Software (DMSW) that relates to drug production considering software modification. Because DMSW that is used for quality management and facility control affects big impact to quality of drugs, regulatory agency required proofs of adequacy for DMSW's functions and performance based on developed documents and test results. Especially, the work that explains adequacy for previously developed DMSW based on existing documents and operational records is called RCSV. When modifying RCSV conducted DMSW, it was difficult to secure consistency between developed documents and test results for modified DMSW parts and existing documents and operational records for non-modified DMSW parts. This made conducting RCSV difficult. In this paper, we proposed (a) definition of documents architecture, (b) definition of descriptive items and levels in the documents, (c) management of design information using database, (d) exhaustive testing, and (e) integrated RCSV procedure. As a result, we could conduct adequate RCSV securing consistency.

  11. Computerized Adaptive Testing with R: Recent Updates of the Package catR

    Directory of Open Access Journals (Sweden)

    David Magis

    2017-01-01

    Full Text Available The purpose of this paper is to list the recent updates of the R package catR. This package allows for generating response patterns under a computerized adaptive testing (CAT framework with underlying item response theory (IRT models. Among the most important updates, well-known polytomous IRT models are now supported by catR; several item selection rules have been added; and it is now possible to perform post-hoc simulations. Some functions were also rewritten or withdrawn to improve the usefulness and performances of the package.

  12. Transversal of Procedure Elements in a Computerized Procedure System

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yeonsub [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    APR1400 MCR(Main Control Room) has introduced CPS(Computerized Procedure System). APR400 CPS is framed with overview pane, step detail pane, and monitoring pane. The overview shows the step in one dimensional array. Diagram in the step detail pane is called as flowlogic diagram. The flowlogic diagram has advantage of being intuitive and not being segmented so that the interfaces are easy to follow and understand. While developing CPS software or training operators these interfaces, however, there is still areas to refine behaviors of flowlogic diagram. If flowlogic diagram has contingency instructions, it is sometime difficult to interpret it properly. Therefore this paper is trying to explain behavior of flowlogic diagram in view of procedure elements. Procedure execution can be called as transversal of steps and instructions in flowlogic diagram. Both hierarchy of procedures elements and flowlogic diagram provides useful framework to test transversal with completeness. Navigation button behaviors are interpreted in view of flowlogic diagram. The framework and flowlogic diagram can be further applied to improve CPS user interfaces.

  13. Validity of Cognitive ability tests – comparison of computerized adaptive testing with paper and pencil and computer-based forms of administrations

    Czech Academy of Sciences Publication Activity Database

    Žitný, P.; Halama, P.; Jelínek, Martin; Květon, Petr

    2012-01-01

    Roč. 54, č. 3 (2012), s. 181-194 ISSN 0039-3320 R&D Projects: GA ČR GP406/09/P284 Institutional support: RVO:68081740 Keywords : item response theory * computerized adaptive testing * paper and pencil * computer-based * criterion and construct validity * efficiency Subject RIV: AN - Psychology Impact factor: 0.215, year: 2012

  14. Reliability of computerized safety systems at nuclear power plants. Report of a technical committee meeting held in Vienna, 21-25 June 1993

    International Nuclear Information System (INIS)

    1995-03-01

    Computer based technology is increasingly used in order to perform safety functions. In some recently designed nuclear power plants the whole safety system is computerized. In older plants replacement of conventional technology based system is seen to be of benefit. If the new technology is to be used, it must meet at least the same level of quality and reliability requirements as specified for conventional technology. However, there is a potential for enhancing the safety of nuclear power plants if the full power of computer technology is applied correctly through well designed, engineered and tested systems which are properly installed and maintained. It is essential that areas where reliability and quality can be improved are identified and that methods for assessing and assuring reliability are developed. The results of the Technical Committee Meeting on Reliability of Computerized Safety Systems at Nuclear Power Plants presented in this report are a step on the road to this goal of improved nuclear safety. Refs, figs and tabs

  15. A computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. I

    International Nuclear Information System (INIS)

    Wouters, F.R.; Jon-And, C.; Frithiof, L.; Soeder, P.Oe.; Lavstedt, S.

    1988-01-01

    The aims of the study were to adapt a computerized system to epidemiologic conditions, for rapid full-mouth measurements of alveolar bone levels from X5-magnified periapical radiographs and to analyze the variations in measurement due to different system components. Full-mouth measurements of interproximal alveolar bone height in percentage of root and tooth lengths were completed within av average time of 15 min. per set of radiographs. An analysis of variance showed that the examiner variation in measurement of a linear scale distance was 0.02 mm. The measurement accuracy was different for different distances. Each distance (d) measured with this system should therefore be calibrated with the equation Y = -0.007 - 0.014 (log 3d - 1.50) where Y is the estimate of measurement accuracy. The present computerized system enabled rapid recordings and demonstrated good measurement precision and accuracy. These are valuable features in epidemiologic investigations

  16. Integration of computerized operation support systems on a nuclear power plant environment

    Energy Technology Data Exchange (ETDEWEB)

    Jaime, Guilherme D.G.; Almeida, Jose C.S.; Oliveira, Mauro V., E-mail: gdjaime@ien.gov.br, E-mail: jcsa@ien.gov.br, E-mail: mvitor@ien.gov.br [Instituto Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Servico de Sistemas Complexos. Divisao de Engenharia Nuclear

    2015-07-01

    Automation of certain tasks in a Nuclear Power Plant (NPP) control room is expected to result in reduced operators' mental workload, which may induce other benefits such as enhanced situation awareness and improved system performance. The final goal should be higher level of operational safety. Thus, recent works are increasingly assessing automation. The LABIHS compact NPP simulator, though, still operates under strictly manual printed hard-copy procedures, despite of the fact that the simulator incorporates several advancements in design of digitalized Human-Interfaces (HSIs). This work presents the development, implementation and integration of selected components to achieve increased level of computerized/automated operation of the LABIHS compact NPP simulator. Specifically, we discuss three components: (I) Automatic Plant Mode Detection, (II) Automatic Alarm Filtering, and (III) Computerized Procedures. Each one of these components has to be carefully designed/integrated so that one can avoid the undesired effects of some known implementations of automated systems on NPP, such as the reduction in the operator's system awareness, an increase in monitoring workload, and the degradation in manual skills, which could lead to automation-induced system failures. (author)

  17. Integration of computerized operation support systems on a nuclear power plant environment

    International Nuclear Information System (INIS)

    Jaime, Guilherme D.G.; Almeida, Jose C.S.; Oliveira, Mauro V.

    2015-01-01

    Automation of certain tasks in a Nuclear Power Plant (NPP) control room is expected to result in reduced operators' mental workload, which may induce other benefits such as enhanced situation awareness and improved system performance. The final goal should be higher level of operational safety. Thus, recent works are increasingly assessing automation. The LABIHS compact NPP simulator, though, still operates under strictly manual printed hard-copy procedures, despite of the fact that the simulator incorporates several advancements in design of digitalized Human-Interfaces (HSIs). This work presents the development, implementation and integration of selected components to achieve increased level of computerized/automated operation of the LABIHS compact NPP simulator. Specifically, we discuss three components: (I) Automatic Plant Mode Detection, (II) Automatic Alarm Filtering, and (III) Computerized Procedures. Each one of these components has to be carefully designed/integrated so that one can avoid the undesired effects of some known implementations of automated systems on NPP, such as the reduction in the operator's system awareness, an increase in monitoring workload, and the degradation in manual skills, which could lead to automation-induced system failures. (author)

  18. Process information displays from a computerized nuclear materials control and accounting system

    International Nuclear Information System (INIS)

    Ellis, J.H.

    1981-11-01

    A computerized nuclear materials control and accounting system is being developed for an LWR spent fuel reprocessing facility. This system directly accesses process instrument readings, sample analyses, and outputs of various on-line analytical instruments. In this paper, methods of processing and displaying this information in ways that aid in the efficient, timely, and safe control of the chemical processes of the facility are described

  19. Computerized automated remote inspection system

    International Nuclear Information System (INIS)

    The automated inspection system utilizes a computer to control the location of the ultrasonic transducer, the actual inspection process, the display of the data, and the storage of the data on IBM magnetic tape. This automated inspection equipment provides two major advantages. First, it provides a cost savings, because of the reduced inspection time, made possible by the automation of the data acquisition, processing, and storage equipment. This reduced inspection time is also made possible by a computerized data evaluation aid which speeds data interpretation. In addition, the computer control of the transducer location drive allows the exact duplication of a previously located position or flaw. The second major advantage is that the use of automated inspection equipment also allows a higher-quality inspection, because of the automated data acquisition, processing, and storage. This storage of data, in accurate digital form on IBM magnetic tape, for example, facilitates retrieval for comparison with previous inspection data. The equipment provides a multiplicity of scan data which will provide statistical information on any questionable volume or flaw. An automatic alarm for location of all reportable flaws reduces the probability of operator error. This system has the ability to present data on a cathode ray tube as numerical information, a three-dimensional picture, or ''hard-copy'' sheet. One important advantage of this system is the ability to store large amounts of data in compact magnetic tape reels

  20. Evaluation of brain scintigraphy and computerized tomography

    International Nuclear Information System (INIS)

    Cavailloles, F.; Dairou, R.; Desbleds, M.T.; Benoit, C.; Larmande, P.; Bok, B.; Alperovitch, A.

    1983-01-01

    In order to assess the clinical usefulness of brain computerized tomography and radionuclide scan, a prospective study was performed on a series of 554 patients. The detection rate was assessed as well as the identification rate of lesions. In addition, the usefulness of both tests was appreciated subjectively by two neurologists reviewing the patients' files. Both give reasonably similar results: computerized tomography is superior to radionuclide scan in the diagnosis of tumors and intracerebral hematomas, the radionuclide scan being slightly superior in the diagnosis of purely ischemic CVA and subdural hematomas. The superiority which was subjectively conceded to computerized tomography was greater than that objectively demonstrated. However, clinical usefulness of computerized tomography was judged important in only 50% of the cases. Moreover, to request both computerized tomography and radionuclide scan appeared as having no interest in 83% of the cases. In that series, the diagnostic hypotheses were in agreement with the final diagnosis in 88% of the cases. Bias encountered in this type of studies are discussed [fr

  1. Application of computerized procedure system for AP1000

    International Nuclear Information System (INIS)

    Wen Fang

    2012-01-01

    With the tendency of digitalisation in instrumentation and control system of nuclear power plants, AP1000, as well as other advanced PWRs, is provided with the technical basis for the application of CPS (computerized procedure system). This paper makes a brief introduction on CPS construction and function. CPS, as an advanced procedure system, does not only have the function of electronic indication for operation procedures, but also have the ability to monitor plant data, process the data and then present the status of the procedure steps to the reactor operator. In addition, advantages of CPS compared with paper-based procedures and comparison with digital operating system of one M310 plus advanced nuclear power plant are described. Moreover, based on current situation, this paper offers several suggestions on CPS localization for Sanmen AP1000 nuclear power project. Besides, the last part of this paper discusses problems we might meet during the process of CPS localization. (author)

  2. Development of BWR computerized operator support system for emergency conditions

    International Nuclear Information System (INIS)

    Murata, F.

    1984-01-01

    A BWR computerized operator support system (COSS) for emergency conditions has been under development for three years. The conceptual design of the system has been settled and some of the subsystems are in the detailed design or manufacturing stage. The principal functions are technical specification monitoring, diagnosis, guidance during emergency conditions, predictive simulation and safety monitoring. Before a reactor trip, alternative operational guidance for anomalous events is provided by utilization of the CTT (cause consequence tree) and FPS (failure propagation simulator). After the trip, operational guidance is based on event-oriented and symptom-oriented methods in association with the safety function monitor. The technical specification monitor controls the readiness monitor and performs surveillance tests of safety systems to maintain plant operational reliability and to ensure correct performance when initiated. The predictive simulator gives the future trends of significant plant parameters. These subsystems are expected to assist the operational personnel. The feasibility of the COSS functions is confirmed separately by off-line simulation. The paper considers the conceptual design, the functions of the subsystems and the off-line simulation results. Each subsystem has shown that useful information to operational personnel is provided. Henceforth these functions will be integrated into a single system and the feasibility will be thoroughly evaluated using a plant simulator which is being separately developed to verify the COSS. (author)

  3. Materials testing by computerized tomography with neutrons and gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    El-Ghobary, A M; Bakkoush, F A; Megahid, R M [Reactor and Neutron Physics Department, Nuclear Research Center, A.E.A., Cairo (Egypt)

    1997-12-31

    The method of computerized tomography by fast neutrons and gamma-rays are used for inspecting and testing of materials by non-destructive technique. The transmission technique was applied using narrow collimated beams of reactor neutrons and gamma-ray. The neutron and gamma-rays transmitted through the object inspection were measured by means of a neutron gamma detector with Ne - 213 liquid organic scintillator. The undesired pulses of neutrons or gamma-rays are rejected from the transmitted beam by a discrimination technique based on the difference in the decay part of light pulse produced by recoil electrons or recoil protons. The transmitted neutrons or gamma-rays for different projections used to get the image of the section through the object investigated using the method of filtered back projection (FBP) algorithm. 8 figs.

  4. Simulator testing of the Westinghouse aware alarm management system

    International Nuclear Information System (INIS)

    Carrera, J.P.; Easter, J.R.; Roth, E.M.

    1997-01-01

    Over the last year, Westinghouse engineers and operators from the Beznau nuclear power station (KKB), owned by the Nordostschweizerische Krafwerke AG of Baden, Switzerland, have been installing and testing the Westinghouse AWARE Alarm Management System in Beznau/SNUPPS operator training simulator, owned and operated by the Westinghouse Electric Corp., in Waltz Mill, PA, USA. The testing has focused primarily on validating the trigger logic data base and on familiarizing the utility's training department with the operation of the system in a real-time environment. Some of the tests have included plant process scenarios in which the computerized Emergency Procedures were available and used through the COMPRO (COMputerized PROcedures) System in conjunction with the AWARE System. While the results to date are qualitative from the perspective of system performance and improvement in message presentation, the tests have generally confirmed the expectations of the design. There is a large reduction in the number of messages that the control room staff must deal with during major process abnormalities, yet at times of relative minor disturbances, some additional messages are available which add clarification, e.g., ''Pump Trouble'' messages. The ''flow'' of an abnormality as it progresses from one part of the plant's processes to another is quite visible. Timing of the messages and the lack of message avalanching is proving to give the operators additional time to respond to messages. Generally, the anxiety level to ''do something'' immediately upon a reactor trip appears to be reduced. (author). 8 refs

  5. Use of computerized tests to evaluate psychomotor performance in children with specific learning disabilities in comparison to normal children

    Directory of Open Access Journals (Sweden)

    Santosh Taur

    2014-01-01

    Full Text Available Background & objectives: Children with specific learning disabilities (SpLD have an unexplained difficulty in acquiring basic academic skills resulting in a significant discrepancy between their academic potential and achievements. This study was undertaken to compare the performance on a battery of six psychomotor tests of children with SpLD and those without any learning disabilities (controls using computerized tests. Methods: In this study, 25 children with SpLD and 25 controls (matched for age, socio-economic status and medium of instruction were given three training sessions over one week. Then children were asked to perform on the six computerized psychomotor tests. Results were compared between the two groups. Results: Children with SpLD fared significantly worse on finger tapping test, choice reaction test, digit picture substitution test and card sorting test compared to the controls ( p <0.05. Interpretation & conclusions: Children with SpLD have impairment of psychomotor skills like attention, sensory-motor coordination and executive functioning. Further research is needed to evaluate if the remedial education plan results in improvement in psychomotor performance of children with SpLD on these selected tests.

  6. A hard tissue cephalometric comparative study between hand tracing and computerized tracing

    Directory of Open Access Journals (Sweden)

    Ramachandra Prabhakar

    2014-01-01

    Full Text Available Aims: To analyze and compare the angular and linear hard tissue cephalometric measurements using hand-tracing and computerized tracings with Nemoceph and Dolphin software systems. Subjects and Methods: A total of 30 cephalograms were randomly chosen for study with the following criteria, cephalograms of patients with good contrast, no distortion, and minimal radiographic artifacts were considered using the digital method (Kodak 8000 C with 12 angular and nine linear parameters selected for the study. Comparisons were determined by post-hoc test using Tukey HSD method. The N-Par tests were performed using Kruskal-Walli′s method. Statistical Analysis Used: ANOVA and post-hoc. Results: The results of this study show that there is no significant difference in the angular and linear measurements recorded. The P values were significant at 0.05 levels for two parameters, Co-A and Co-Gn with the hand-tracing method. This was significant in ANOVA and post-hoc test by Tukey HSD method. Conclusions: This study of comparison provides support for transition from digital hand to computerized tracing methodology. In fact, digital computerized tracings were easier and less time consuming, with the same reliability irrespective of each method of tracing.

  7. The use of inverse systems in computerized operator support systems for load-following control

    International Nuclear Information System (INIS)

    Klebau, J.; Hentschel, B.; Ziegenbein, D.

    1987-01-01

    The basic problem in load-following control of nuclear power reactors consists in calculation of control rod movement to realize desired local power density distribution in the reactor. Well-known solutions are based on optimal control theory. The paper describes the concept of systems inverses which makes it possible to solve the load-following control problem not in an optimal but in an 'ideal' way, vanishing the optimization criterion of the classical approaches. The advantages of inverse systems are simple calculation procedures, low on-line-storage capacity and low on-line computational amount. This makes it attractive to use inverse systems in computerized operator support systems. 19 refs. (author)

  8. Development of a computerized adaptive test for Schizotypy assessment.

    Directory of Open Access Journals (Sweden)

    Eduardo Fonseca-Pedrero

    Full Text Available BACKGROUND: Schizotypal traits in adolescents from the general population represent the behavioral expression of liability for psychotic disorders. Schizotypy assessment in this sector of population has advanced considerably in the last few years; however, it is necessary to incorporate recent advances in psychological and educational measurement. OBJECTIVE: The main goal of this study was to develop a Computerized Adaptive Test (CAT to evaluate schizotypy through "The Oviedo Questionnaire for Schizotypy Assessment" (ESQUIZO-Q, in non-clinical adolescents. METHODS: The final sample consisted of 3,056 participants, 1,469 males, with a mean age of 15.9 years (SD=1.2. RESULTS: The results indicated that the ESQUIZO-Q scores presented adequate psychometric properties under both Classical Test Theory and Item Response Theory. The Information Function estimated using the Gradual Response Model indicated that the item pool effectively assesses schizotypy at the high end of the latent trait. The correlation between the CAT total scores and the paper-and-pencil test was 0.92. The mean number of presented items in the CAT with the standard error fixed at ≤ 0.30 was of 34 items. CONCLUSION: The CAT showed adequate psychometric properties for schizotypy assessment in the general adolescent population. The ESQUIZO-Q adaptive version could be used as a screening method for the detection of adolescents at risk for psychosis in both educational and mental health settings.

  9. Testing objects in Computerized Axial Tomography. Contributions to the Spanish Protocol on quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    Villaescusa, J.I.; Campayo, J.M.

    1995-01-01

    In the provisional version of the Spanish Protocol about the technical aspects of Quality Control in Radiodiagnostic,SEFM-SEPR 1993, it is dedicated a section to Computerized Axial tomography, establishing a total of eleven technical parameters of the equipment for examination. The present work describes the practical use of the Protocol using various types of Test Object. The authors also propose new tests that should be considered in the final version of the Spanish Protocol. (Author)

  10. The evolution of the market for commercial computerized physician order entry and computerized decision support systems for prescribing.

    Science.gov (United States)

    Mozaffar, Hajar; Williams, Robin; Cresswell, Kathrin; Morrison, Zoe; Bates, David W; Sheikh, Aziz

    2016-03-01

    To understand the evolving market of commercial off-the-shelf Computerized Physician Order Entry (CPOE) and Computerized Decision Support (CDS) applications and its effects on their uptake and implementation in English hospitals. Although CPOE and CDS vendors have been quick to enter the English market, uptake has been slow and uneven. To investigate this, the authors undertook qualitative ethnography of vendors and adopters of hospital CPOE/CDS systems in England. The authors collected data from semi-structured interviews with 11 individuals from 4 vendors, including the 2 most entrenched suppliers, and 6 adopter hospitals, and 21 h of ethnographic observation of 2 user groups, and 1 vendor event. The research and analysis was informed by insights from studies of the evolution of technology fields and the emergence of generic COTS enterprise solutions. Four key themes emerged: (1) adoption of systems that had been developed outside of England, (2) vendors' configuration and customization strategies, (3) localized adopter practices vs generic systems, and (4) unrealistic adopter demands. Evidence for our over-arching finding concerning the current immaturity of the market was derived from vendors' strategies, adopters' reactions to the technology, and policy makers' incomplete insights. The CPOE/CDS market in England is still in an emergent phase. The rapid entrance of diverse products, triggered by federal policy initiatives, has resulted in premature adoption of systems that do not yet adequately meet the needs of hospitals. Vendors and adopters lacked understanding of how to design and implement generic solutions to meet diverse user needs. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Computerized database management system for breast cancer patients.

    Science.gov (United States)

    Sim, Kok Swee; Chong, Sze Siang; Tso, Chih Ping; Nia, Mohsen Esmaeili; Chong, Aun Kee; Abbas, Siti Fathimah

    2014-01-01

    Data analysis based on breast cancer risk factors such as age, race, breastfeeding, hormone replacement therapy, family history, and obesity was conducted on breast cancer patients using a new enhanced computerized database management system. My Structural Query Language (MySQL) is selected as the application for database management system to store the patient data collected from hospitals in Malaysia. An automatic calculation tool is embedded in this system to assist the data analysis. The results are plotted automatically and a user-friendly graphical user interface is developed that can control the MySQL database. Case studies show breast cancer incidence rate is highest among Malay women, followed by Chinese and Indian. The peak age for breast cancer incidence is from 50 to 59 years old. Results suggest that the chance of developing breast cancer is increased in older women, and reduced with breastfeeding practice. The weight status might affect the breast cancer risk differently. Additional studies are needed to confirm these findings.

  12. Development of computerized adaptive testing (CAT) for the EORTC QLQ-C30 physical functioning dimension

    DEFF Research Database (Denmark)

    Petersen, Morten Aa; Groenvold, Mogens; Aaronson, Neil K

    2011-01-01

    Computerized adaptive test (CAT) methods, based on item response theory (IRT), enable a patient-reported outcome instrument to be adapted to the individual patient while maintaining direct comparability of scores. The EORTC Quality of Life Group is developing a CAT version of the widely used EORTC...... QLQ-C30. We present the development and psychometric validation of the item pool for the first of the scales, physical functioning (PF)....

  13. The effects of mild and severe traumatic brain injury on speed of information processing as measured by the computerized tests of information processing (CTIP).

    Science.gov (United States)

    Tombaugh, Tom N; Rees, Laura; Stormer, Peter; Harrison, Allyson G; Smith, Andra

    2007-01-01

    In spite of the fact that reaction time (RT) measures are sensitive to the effects of traumatic brain injury (TBI), few RT procedures have been developed for use in standard clinical evaluations. The computerized test of information processing (CTIP) [Tombaugh, T. N., & Rees, L. (2000). Manual for the computerized tests of information processing (CTIP). Ottawa, Ont.: Carleton University] was designed to measure the degree to which TBI decreases the speed at which information is processed. The CTIP consists of three computerized programs that progressively increase the amount of information that is processed. Results of the current study demonstrated that RT increased as the difficulty of the CTIP tests increased (known as the complexity effect), and as severity of injury increased (from mild to severe TBI). The current study also demonstrated the importance of selecting a non-biased measure of variability. Overall, findings suggest that the CTIP is an easy to administer and sensitive measure of information processing speed.

  14. Developing a computerized aging management system for concrete structures in finnish nuclear power plants

    International Nuclear Information System (INIS)

    Al-Neshawy, F.; Piironen, J.; Sistonen, E.; Vesikari, E.; Tuomisto, M.; Hradil, P.; Ferreira, M.

    2013-01-01

    Finland has four nuclear reactors units in two power plants. The first unit started operation in 1977 and in the early 1980's all four units were in use. During the last few years the aging management of the Nuclear Power Plant's (NPP) concrete structures has grown an important issue because the existing structures are reaching the end of their licensed operating lifetime (about 40 years). Therefore the nuclear power companies are developing aging management systems to avoid premature degradation of NPP facilities and to be able to extend their operating lifetime. This paper is about the development of a computerized ageing management system for the nuclear power plants concrete structures. The computerized ageing management system is built upon central database and implementation applications. It will assist the personnel of power companies to implement the aging management activities at different phases of the lifetime of a power plant. It will provide systematic methods for planning, surveillance, inspection, monitoring, condition assessment, maintenance and repair of structures. (authors)

  15. The water reactor safety research project index: a description of the computerized system for its databank

    International Nuclear Information System (INIS)

    Della Loggia, E.; Primavera, R.

    1993-01-01

    The water reactor nuclear safety research project index has been published by the CEC for many years as a compilation of information on research projects relating to LWR nuclear safety. Since 1981, it has been published, alternatively with NEA (OECD), every second year. The number of contributions from research organizations in Community member countries has steadily increased and reached the level of 1 700 pages, in which more than 600 project descriptions have been collected. In 1988, for the first time, the document was produced using a computerized system developed with the assistance of the ISEI (Institute for Systems Engineering and Informatics) of JRC Ispra. The data have been stored in a computer based in Ispra. The system allows searching a preselected set of subjects through the information stored in the computer: it makes the updating of the projects description much easier and makes the retrieval of the data possible. This report presents a short description of the computerized system developed for the databank of the index. The computerized system presented in this report is structured in a quite general way and for that reason can be adapted very easily to every field where a databank needs to be constituted in order to collect extended information on several projects. (authors). 6 figs., 5 tabs., 5 refs

  16. The computerized system of meteorology data process for nuclear power plant

    International Nuclear Information System (INIS)

    Yan Jun; Dai Zhongde; Huang Haitao; Zhang Yiqing; Gu Zhijie

    1994-06-01

    Based on some specifications of the second-stage of the Qinshan Nuclear Power Plant and combined with advantages of STD-BUS, the computerized acquisition system with 7 kinds of meteorology data was developed. The system was put into operation in Nov. 1991, and acquisition rate reached 90% in one year. The system consists of two sub-systems, 7 kinds of meteorology sensors and their interface. Rain and sun radiation quantities are transmitted by means of V/F conversion. In order to enhance the system reliability all sensors are calibrated, the industrial control computer with STD-BUS is applied. The system has keyboard, micro-printer and LED display with block construction and has good resistance to interference

  17. A production system for computerized emergency procedures tracking

    International Nuclear Information System (INIS)

    Petrick, W.; Ng, K.; Stuart, C.; Cain, D.

    1988-01-01

    This paper describes a methodology used to implement a computerized Emergency Operating Procedures (EOP) tracking system based on artificial intelligence (AI) technologies. In AI parlance, the system is a production system in which the knowledge representation is a set of productions (IF-THEN rules) which are interpreted by an inference engine or rule interpreter. The inference engine looks for pattern matches in the rule premises which lead to a conclusion. This inferred conclusion is subsequently used in further pattern matches. By separating the knowledge representation from the inference engine, the system can readily accommodate changes to the written procedures. The system is written in the C language and is co-resident on the same computer as the Safety Parameter Display System (SPDS). The plant EOPs have been written in about 250 rules which are evaluated in less than one second using about 10-20% of the CPU. The conclusions are available to multiple users within seconds after a parameter value changes. The benefits achieved with this production rule system include compatibility with the written procedures used as the knowledge source, compatibility with control room instrumentation, compatibility with the SPDS, realtime performance, and efficient computer usage

  18. The Computerized Table Setting Test for Detecting Unilateral Neglect.

    Directory of Open Access Journals (Sweden)

    Seok Jong Chung

    Full Text Available Patients with unilateral neglect fail to respond normally to stimuli on the left side. To facilitate the evaluation of unilateral spatial neglect, we developed a new application that runs on a tablet device and investigated its feasibility in stroke patients.We made the computerized table setting test (CTST to run on the tablet computer. Forty acute ischemic stroke patients (20 patients with right hemispheric infarction with neglect, 10 patients with right hemispheric infarction without neglect, and 10 patients with left hemispheric infarction and 10 healthy controls were prospectively enrolled to validate the CTST. The test requires subjects to set a table by dragging 12 dishes located below the table on the tablet screen. The horizontal deviation of the 12 dishes from the midline of the table, the selection tendency measured by the sequence of the dish selection, and the elapsed time for table setting were calculated automatically.Parameters measured by the CTST were correlated with the results of conventional neglect tests. The horizontal deviation was significantly higher in patients with right hemispheric infarction with neglect compared with the other groups. The selection tendency and elapsed time also were significantly different in patients with right hemispheric infarction with neglect compared with the left hemispheric infarction and control groups, but were similar to those with right hemispheric infarction without neglect.The CTST is feasible to administer and comparable with conventional neglect tests. This new application may be useful for the initial diagnosis and follow-up of neglect patients.

  19. [Introduction of computerized anesthesia-recording systems and construction of comprehensive medical information network for patients undergoing surgery in the University of Tokyo Hospital].

    Science.gov (United States)

    Kitamura, Takayuki; Hoshimoto, Hiroyuki; Yamada, Yoshitsugu

    2009-10-01

    The computerized anesthesia-recording systems are expensive and the introduction of the systems takes time and requires huge effort. Generally speaking, the efficacy of the computerized anesthesia-recording systems on the anesthetic managements is focused on the ability to automatically input data from the monitors to the anesthetic records, and tends to be underestimated. However, once the computerized anesthesia-recording systems are integrated into the medical information network, several features, which definitely contribute to improve the quality of the anesthetic management, can be developed; for example, to prevent misidentification of patients, to prevent mistakes related to blood transfusion, and to protect patients' personal information. Here we describe our experiences of the introduction of the computerized anesthesia-recording systems and the construction of the comprehensive medical information network for patients undergoing surgery in The University of Tokyo Hospital. We also discuss possible efficacy of the comprehensive medical information network for patients during surgery under anesthetic managements.

  20. Failed fuel rod detection system and computerized manipulator during outages

    International Nuclear Information System (INIS)

    Boehm, H.H.; Foerch, H.

    1984-01-01

    During regular outages spent fuel assemblies need to be replaced and relocated within the core. Defective fuel rods in particular fuel assemblies have to be removed from further service and before delivery of such faulty fuel assemblies to a reprocessing plant. The system which Brown Boveri Reaktor GmbH and Krautkraemer have developed in the Federal Republic of Germany is capable of directly locating the defective rods in a proper fuel assembly. Inspection times are comparable to those of standard sipping methods, with the advantages of immediately available results and direct identification of the defective fuel rods. During the repair of fuel assemblies this system allows withdrawal of individual defective rods. With the sipping method all the fuel rods of a defective fuel assembly need to be removed and inspected by eddy current testing. During steam generator inspection and repair personnel are exposed to ample radiation. A remotely controlled, computerized manipulator was used to significantly reduce the radiation dose by automating steps in the procedures; at the same time inspection and repair times were reduced. The main features of the manipulator are a rigid component construction of the leg and two arms, and a resolver control for horizontal and vertical motion that enables rapid and accurate access to a desired tube (author)

  1. Simulator testing of the Westinghouse aware alarm management system

    Energy Technology Data Exchange (ETDEWEB)

    Carrera, J P; Easter, J R; Roth, E M [Westinghouse Electric Corp., Pittsburgh, PA (United States)

    1997-09-01

    Over the last year, Westinghouse engineers and operators from the Beznau nuclear power station (KKB), owned by the Nordostschweizerische Krafwerke AG of Baden, Switzerland, have been installing and testing the Westinghouse AWARE Alarm Management System in Beznau/SNUPPS operator training simulator, owned and operated by the Westinghouse Electric Corp., in Waltz Mill, PA, USA. The testing has focused primarily on validating the trigger logic data base and on familiarizing the utility`s training department with the operation of the system in a real-time environment. Some of the tests have included plant process scenarios in which the computerized Emergency Procedures were available and used through the COMPRO (COMputerized PROcedures) System in conjunction with the AWARE System. While the results to date are qualitative from the perspective of system performance and improvement in message presentation, the tests have generally confirmed the expectations of the design. There is a large reduction in the number of messages that the control room staff must deal with during major process abnormalities, yet at times of relative minor disturbances, some additional messages are available which add clarification, e.g., ``Pump Trouble`` messages. The ``flow`` of an abnormality as it progresses from one part of the plant`s processes to another is quite visible. Timing of the messages and the lack of message avalanching is proving to give the operators additional time to respond to messages. Generally, the anxiety level to ``do something`` immediately upon a reactor trip appears to be reduced. (author). 8 refs.

  2. Review of trends in computerized systems for operator support

    International Nuclear Information System (INIS)

    Cain, D.G.

    1985-01-01

    The major trends shaping the development of computerized operator support systems in nuclear power plants are reviewed. These trends are the result of prior research in disturbance analysis systems that provided the technology base, and the SPDS requirement, which has been the impetus for change. The process is expected to result in hybrid control rooms with computer-driven supervisory workstations that complement conventional control board lay-outs. In the next three to five year period substantial upgrading of computer hardware will allow new and more sophisticated applications routines to be developed for operator support. Greater attention is being given to on-line validation of input signals for computer applications. A general movement towards operating strategies that are not based upon pre-analyzed event sequences is expected to influence the development of operator aids. The integration of displays with operating procedures will enable the computer system to a better coupling between problem detection and its resolution. Improved design methodology will assure that computer applications are accepted and used by operations personnel. Greater on-line analysis capability is stimulating the trend towards more on-site analysis and decision-making at nuclear power plants. Software standardization reflects the high cost of software development and the desire by utilities to gain greater independence from suppliers. There is growing realization that control rooms are beset by many of the demands and limitations of other office settings and that some of these may be addressed by the burgeoning office automation technology. Trends beyond the next five years are difficult to predict; however, there will be a trend towards more intelligent software. Artificial intelligence technology may play a pivotal role in future applications. Taking these trends into perspective, the author concludes that a promising future exists for computerized operator support in nuclear

  3. How to Maintain Computerized Procedure System in the same Version

    International Nuclear Information System (INIS)

    Jung, Yeon Sub

    2016-01-01

    CPS(Computerized Procedure System) has been introduced in advanced nuclear power plant worldwide. Korean CPS complies with this trend. It has been applied to Shinkori3,4 and all their successors including BNPP1,2,3,4. CPS is designed by KHNP CRI, and developed by Westinghouse or Doosan. Initial design has been improved by reflecting operator experience, human factor V and V, and advanced engineering method. Design improvement makes CPS differ from plant to plant. For example CPS in Shinhanul cannot interpret CP(Computerized Procedure) of ShinKori3, 4. Different CPS makes it difficult to utilize CP and train operators. Therefore it is important to keep CPS in single version. Note that typical text editors in the office are kept in single version. On the other hand, plant monitoring systems in main control room are actually different. Because CPS is positioned between text editor and monitoring system, goal to maintain CPS in single version is not an easy task. From Shinkori3,4, lots of improvements are achieved in CPS. This improvement surely makes operation easy and will not introduce human errors. Side effect of improvement is that PXS and CPS ES may not be compatible among nuclear power plants. So the side effect should be avoided by minimizing change of XML. Initial XML had been developed for Shinkori3,4. The XML has been modified slightly for Shinhanul1,2. PXS and CPS ES are being developed for the same version for all nuclear power plants of APR1400

  4. Improvements on computerized procedure system of advanced power reactor 1400 MWe

    International Nuclear Information System (INIS)

    Seong, Nokyu; Jung, Yeonsub; Sung, Chanho; Kang, Sungkon

    2017-01-01

    Plant procedures are instructions to help operator in monitoring, decision making, and controlling Nuclear Power Plants (NPPs). While plant procedures conventionally have been paper-based, computerized-based procedures are being implemented to reduce the drawbacks of paper-based procedures in many nuclear power plants. The Computerized Procedure System (CPS) designed by Korea Hydro and Nuclear Power Central Research Institute (KHNP CRI) is one of the human-system interfaces (HSIs) in digitalized Main Control Room (MCR) of APR1400 (Advanced Power Reactor 1400 MWe). Currently, CPS is being applied to constructing nuclear power plants of Korea and Barakah NPP 1, 2, 3 and 4 units of United Arab Emirates. The CPS has many advantages to perform the procedure in fully digitalized MCR. First, CPS provides the procedure flow with logic diagram to operators. The operator easily can be aware of the procedure flow from a previous instruction to the next instruction and also can find out the relation between parent instruction and child instructions such as AND, OR and SEQUENCE logics. Second, CPS has three logic-based functions such as procedure entry condition monitoring logic, continuously applied step (CAS) re-execution monitoring logic and auto evaluation logic on instructions. E.g. CPS provides the standard post trip actions procedure open popup message when the reactor trips by calculating the entry condition logic that procedure writer had made in the writing process. Third, CPS can directly display the task information related to instructions such as valves, pumps, process parameters, etc. and also the operator can call the system display related to procedure execution. If an operator clicks the system display link, the related system display popups on the right side monitor of CPS display. Lastly, CPS supports the synchronization of procedure among the operators. This synchronization function helps operators to succeed the goal of procedure and improve the situation

  5. Experience feedback of computerized controlled nuclear power plants

    International Nuclear Information System (INIS)

    Poizat, F.

    2004-01-01

    The N4 step of French PWR-type nuclear power plants is characterized by an instrumentation and control system entirely computerized (operation procedures including normal and accidental operation). Four power plants of this type (Chooz and Civaux sites) of 1450 MWe each were connected to the power grid between August 1996 and December 1999. The achievement of this program make it possible and necessary to carry out an experience feedback about the development, successes and difficulties encountered in order to draw out some lessons for future realizations. This is the aim of this article: 1 - usefulness and difficulties of such an experience feedback: evolution of instrumentation and control systems, necessary cautions; 2 - a successful computerized control: checking of systems operation, advantages, expectations; 3 - efficiency of computerized systems: demonstration of operation safety, profitability; 4 - conclusions and interrogations: system approach instead of 'micro-software' approach, commercial or 'made to measure' products, contract agreement with a supplier, when and how upgrading. (J.S.)

  6. A Novel Computerized Test for Detecting and Monitoring Visual Attentional Deficits and Delirium in the ICU.

    Science.gov (United States)

    Green, Cameron; Hendry, Kirsty; Wilson, Elizabeth S; Walsh, Timothy; Allerhand, Mike; MacLullich, Alasdair M J; Tieges, Zoë

    2017-07-01

    Delirium in the ICU is associated with poor outcomes but is under-detected. Here we evaluated performance of a novel, graded test for objectively detecting inattention in delirium, implemented on a custom-built computerized device (Edinburgh Delirium Test Box-ICU). A pilot study was conducted, followed by a prospective case-control study. Royal Infirmary of Edinburgh General ICU. A pilot study was conducted in an opportunistic sample of 20 patients. This was followed by a validation study in 30 selected patients with and without delirium (median age, 63 yr; range, 23-84) who were assessed with the Edinburgh Delirium Test Box-ICU on up to 5 separate days. Presence of delirium was assessed using the Confusion Assessment Method for the ICU. The Edinburgh Delirium Test Box-ICU involves a behavioral assessment and a computerized test of attention, requiring patients to count slowly presented lights. Thirty patients were assessed a total of 79 times (n = 31, 23, 15, 8, and 2 for subsequent assessments; 38% delirious). Edinburgh Delirium Test Box-ICU scores (range, 0-11) were lower for patients with delirium than those without at the first (median, 0 vs 9.5), second (median, 3.5 vs 9), and third (median, 0 vs 10.5) assessments (all p Delirium Test Box-ICU score less than or equal to 5 was 100% sensitive and 92% specific to delirium across assessments. Longitudinally, participants' Edinburgh Delirium Test Box-ICU performance was associated with delirium status. These findings suggest that the Edinburgh Delirium Test Box-ICU has diagnostic utility in detecting ICU delirium in patients with Richmond Agitation and Sedation Scale Score greater than -3. The Edinburgh Delirium Test Box-ICU has potential additional value in longitudinally tracking attentional deficits because it provides a range of scores and is sensitive to change.

  7. Software design for the Tritium System Test Assembly

    International Nuclear Information System (INIS)

    Claborn, G.W.; Heaphy, R.T.; Lewis, P.S.; Mann, L.W.; Nielson, C.W.

    1983-01-01

    The control system for the Tritium Systems Test Assembly (TSTA) must execute complicated algorithms for the control of several sophisticated subsystems. It must implement this control with requirements for easy modifiability, for high availability, and provide stringent protection for personnel and the environment. Software techniques used to deal with these requirements are described, including modularization based on the structure of the physical systems, a two-level hierarchy of concurrency, a dynamically modifiable man-machine interface, and a specification and documentation language based on a computerized form of structured flowcharts

  8. Software design for the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Claborn, G.W.; Keaphy, R.T.

    1983-01-01

    The control system for the Tritium Systems Test Assembly (TSTA) must execute complicated algorithms for the control of several sophisticated subsystems. It must implement this control with requirements for easy modifiability, for high availability, and provide stringent protection for personnel and the environment. Software techniques used to deal with these requirements are described, including modularization based on the structure of the physical systems, a two-level hierarchy of concurrency, a dynamically modifiable manmachine interface, and a specification and documentation language based on a computerized form of structured flowcharts

  9. Computerized systems for high level information processing and decision making in the field of PSA

    International Nuclear Information System (INIS)

    Kafka, P.; Kunitz, H.

    1990-01-01

    A comprehensive review of Probabilistic Safety Assessment (PSA) related program packages is made. Three fields in methodological succession are covered: plant modeling, data quantification procedures and decision-making support. Packages for fault tree construction and minimal cut sets evaluation are referred to and the performances of three of them: RALLY, ORCHARD and SALP-PC, are discussed and compared. Notions on the raw data sources are presented and the Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is given as an example for data base management system generating PSA data. Aggregated risk models for support in safety assessment, plant operation and accident management (SARA, ESSM, PRISIM) are cited. Examples of systems supporting 'living PSA' (SAIS, SUPER-NET, LESSEPS 1300, NUPRA, SPSA) are given. The concluding remarks outline the state-of-the-art developments of computerized systems for reliability analyses. 1 fig., 1 tab., 51 refs. (R.Ts)

  10. Experience feedback learned from commissioning and operation of the fully computerized I and C system of the French N4 series

    International Nuclear Information System (INIS)

    Maillart, H.

    1999-01-01

    The I and C system of new N4 series of French Nuclear Power Plant, has a fully computerized multilevel architecture from process to technical management. This I and C system includes a computerized control room, which allows seated operation from compact computerized workstations in the control room in the full range of operation situations. This architecture makes a deep use of diversification and redundancy at each level. A CAD tool ensures management, quality and consistency of the data in the different systems of the architecture. Major companies have participated in this project : FRAMATOME together with SCHNEIDER ELECTRIC (Reactor Protection and Control Systems Vendor) and SEMA GROUP together with BAILEY-SEREG HARTMANN and BRAUN (General Automation and Central Data Processing Systems Vendor). The assessment of project performance and the first months of operation of the N4 I and C system that can be established as of now is completely positive: firstly, it confirms the ability of a fully computerized I and C system to meet the reliability, dependability and operation constraints necessary for the control of a nuclear plant unit, secondly, it confirms the validity of the technical choices made by EDF and its suppliers, lastly, this period of operation allows the validation of the choices made for the organization and architecture of the CAD chain upstream of the system. (author)

  11. Computerized training program usage at the Fort Calhoun Nuclear Power Station

    International Nuclear Information System (INIS)

    Ruzic, D.H.; Reed, W.H.; Lawton, R.K.; Fluehr, J.J.

    1987-01-01

    The increased US Nuclear Regulatory Commission and Institute of Nuclear Power Operations (INPO) interest in the nuclear power industry training programs resulted in the Omaha Public Power District staff at the Fort Calhoun Nuclear Power Station investigating the potential for computerizing their recently accredited training records, student training requirements, and the process of determining student certification status. Additional areas that were desirable were a computerized question data bank with random test generation, maintaining history of question usage, and tracking of the job task analysis process and course objectives. SCI Software's online personnel training information management system (OPTIM) was selected, subsequent to a bid evaluation, to provide these features while operating on the existing corporate IBM mainframe

  12. Antipsychotic treatment in schizophrenia: the role of computerized neuropsychological assessment.

    Science.gov (United States)

    Kertzman, Semion; Reznik, Ilya; Grinspan, Haim; Weizman, Abraham; Kotler, Moshe

    2008-01-01

    The present study analyzes the role of neurocognitive assessment instruments in the detection of the contribution of antipsychotic treatment to cognitive functioning. Recently, a panel of experts suggested six main domains (working memory; attention/vigilance; verbal/visual learning and memory; reasoning and problem solving; speed of processing) implicated in schizophrenia-related cognitive deficits, which serve as a theoretical base for creation of real-time computerized neurocognitive batteries. The high sensitivity of computerized neuropsychological testing is based on their ability to adopt the reaction time (RT) paradigm for the assessment of brain function in a real-time regime. This testing is highly relevant for the monitoring of the cognitive effects of antipsychotics. Computerized assessment assists in the identification of state- and trait-related cognitive impairments. The optimal real-time computerized neurocognitive battery should composite balance between broad and narrow coverage of cognitive domains relevant to the beneficial effects of antipsychotics and will enable better planning of treatment and rehabilitation programs.

  13. Acceptance and implementation of a system of planning computerized based on Monte Carlo

    International Nuclear Information System (INIS)

    Lopez-Tarjuelo, J.; Garcia-Molla, R.; Suan-Senabre, X. J.; Quiros-Higueras, J. Q.; Santos-Serra, A.; Marco-Blancas, N.; Calzada-Feliu, S.

    2013-01-01

    It has been done the acceptance for use clinical Monaco computerized planning system, based on an on a virtual model of the energy yield of the head of the linear electron Accelerator and that performs the calculation of the dose with an algorithm of x-rays (XVMC) based on Monte Carlo algorithm. (Author)

  14. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  15. Computerized access to materials data. A progress report

    International Nuclear Information System (INIS)

    Rumble, J. Jr.

    1985-01-01

    As the effort to build a comprehensive computerized materials data system grows, it becomes more obvious that the benefits will be far-reaching. During this workshop, the enthusiasm of the participants grew steadily until the questions became not''What,'' but ''When?''. The engineering community within the United States has banded together many times to advance progress in engineering capability. The computerized materials data system requires such an effort, and the rewards will be substantial. Chapter 3 identifies changes in the use of materials data in the Nuclear Power Industry. Chapter 4 describes the EPRI experience in building computerized materials databases. In Chapter 5, the National Materials Property Data Network is discussed. The next four chapters present summaries of the workshop discussions and its conclusions. Chapter 6 discusses the content of the proposed system, Chapter 7 its size and the data sources, and Chapter 8 the user interfaces and system capabilities. In Chapter 9, ways of making further progress are outlined

  16. Computerization of the safeguards analysis decision process

    International Nuclear Information System (INIS)

    Ehinger, M.H.

    1990-01-01

    This paper reports that safeguards regulations are evolving to meet new demands for timeliness and sensitivity in detecting the loss or unauthorized use of sensitive nuclear materials. The opportunities to meet new rules, particularly in bulk processing plants, involve developing techniques which use modern, computerized process control and information systems. Using these computerized systems in the safeguards analysis involves all the challenges of the man-machine interface experienced in the typical process control application and adds new dimensions to accuracy requirements, data analysis, and alarm resolution in the regulatory environment

  17. Outline of a computerized nuclear material accounting system applicable to nuclear power reactors

    International Nuclear Information System (INIS)

    Handshuh, J.W.

    1975-01-01

    A computerized nuclear material accounting system is described which enables a utility to account for its material throughout the entire fuel cycle. From input of transactions, the system records and reports inventories and transactions by accounts which the user may establish for discrete locations, item control areas, further subdivisions, and material types. Account numbers are designed so that accounts and records are automatically sorted in the order desired. The system also generates the Material Status Reports for the Nuclear Regulatory Commission

  18. Integrated System Validation Usability Questionnaire: Computerized Procedures

    International Nuclear Information System (INIS)

    Garcés, Ma. I.; Torralba, B.

    2015-01-01

    The Research and Development (R&D) project on “Theoretical and Methodological Approaches to Integrated System Validation of Control Rooms, 2014-2015”, in which the research activities described in this report are framed, has two main objectives: to develop the items for an usability methodology conceived as a part of the measurement framework for performance-based control room evaluation that the OECD Halden Reactor Project will test in the experiments planned for 2015; and the statistical analysis of the data generated in the experimental activities of the Halden Man-Machine Laboratory (HAMMLAB) facility, with previous usability questionnaires, in 2010 and 2011. In this report, the procedure designed to meet the first goal of the project is described, in particular, the process followed to identify the items related to operating procedures, both computer and paper-based, one of the elements to be included in the usability questionnaire. Three phases are performed, in the first one, the approaches developed by the United States Nuclear Regulatory Commission, NRC, are reviewed, the models used by the nuclear industry and their technical support organizations, mainly, the Electric Power Research Institute, EPRI, are analyzed, and scientist advances are also explored. In the remaining stages, general and specific guidelines for computerized and paper-based procedures are compared and criteria for the preliminary selection of the items that should be incorporated into the usability questionnaire are defined. This proposal will be reviewed and adapted by the Halden Reactor Project to the design of the specific experiments performed in HAMLAB.

  19. Computerized asset management and maintenance systems in ST

    CERN Document Server

    Sánchez-Corral, E

    1999-01-01

    The ST division manages and therefore maintains the CERN technical installations. A maintenance database application exists for every technical domain. A total of six different databases were built during the last 10 years and are based on the RAPIER maintenance program. As the Computerized Asset Management and Maintenance Systems (CAMMS) technology has evolved, the RAPIER system has become obsolete. Therefore we are forced to migrate to its latest version, MP5, before the year 2000. The migration path must be defined, leading from the current situation to a fully operational MP5 application. The major elements of each migration path consist in determining the functionality to use, defining the operation of it, adapting and/or creating procedures, converting data and providing training. A migration is always a process of change. The migration presents a unique opportunity to evaluate the current implementations, adapt them to the requirements and exploit the new features offered. Obsolete data and inconsisten...

  20. Quality control of online calibration in computerized assessment

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    In computerized adaptive testing, updating item parameter estimates using adaptive testing data is often called online calibration. This study investigated how to evaluate whether the adaptive testing data used for online calibration sufficiently fit the item response model used. Three approaches

  1. Progress of Design Improvements for APR1400 Computerized Procedure System from HFE V and V results and Design Experience

    International Nuclear Information System (INIS)

    Lee, Sungjin; Seong, Nokyu

    2015-01-01

    This study shows major already improved design features from the above three processes and a design proposal for to-be-improving items. APR1400 CPS has been verified and validated by the HFE process, internal design review and site acceptance tests. APR1400 Computerized Procedure System (CPS) has been applied to Shin-Kori Nuclear Power Plant (SKN) 3 and 4 units, Shin-Hanul Nuclear Power Plant (SHN) 1 and 2 units and Baraka Nuclear Power Plant (BNPP) 1, 2, 3 and 4 units. Since APR1400 CPS is a first-of-a-kind (FOAK) human machine interface (HMI) for executing a computerized procedure in the nuclear power plant's main control room in South Korea, it has been continuously improved through a) the human factor engineering (HFE) verification and validation (V and V), b) the internal design review and c) prototype tests. Human engineering discrepancies (HEDs) can be identified by the HFE V and V activity. Some HEDs of APR1400 CPS for SKN 3 and 4 and SHN 1 and 2 have been adopted as a role of design improvement in the CPS system while others were regarded as an operator training requirement or part of task contents. Various requests for improving the CPS have been collected from those results. A HMI system should be improved continuously for removing potential defects. Some of introduced design features in this paper has been adopted for APR1400 nuclear power plants. Some of them are under the review in the CPS design team of KHNP

  2. DARE: Unesco Computerized Data Retrieval System for Documentation in the Social and Human Sciences (Including an Analysis of the Present System).

    Science.gov (United States)

    Vasarhelyi, Paul

    The new data retrieval system for the social sciences which has recently been installed in the UNESCO Secretariat in Paris is described in this comprehensive report. The computerized system is designed to facilitate the existing storage systems in the circulation of information, data retrieval, and indexing services. Basically, this report…

  3. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  4. Features of Computerized Procedure System of Shin-Kori unit 5 and 6

    International Nuclear Information System (INIS)

    Seong, Nokyu; Jung, Yeonsub; Sung, Chanho

    2016-01-01

    The Computerized Procedure System (CPS) is one of the Man Machine Interface (MMI) resources of Main Control Room (MCR) of the Advanced Power Reactor 1400 (APR1400). The CPS has been continuously improved since it was installed in Shin-Kori unit 3 and 4. The Korea Hydro Nuclear Power Central Research Institute (KHNP CRI) has found the points of improvement of CPS through CPS centered Human Factors Engineering Verification and Validation (HFE V and V) and Operating Experience Review (OER) of reference power plant. This paper shows the main features of CPS of Shin-Kori 5 and 6 unit. This paper shows the main features of CPS of Shin-Kori 5 and 6. These are some of improvements of CPS. This prototype of CPS currently is implementing in CRI. The respective function can be more detailed after testing the prototype. These features will be applied to Shin-Kori 5 and 6 CPS after HFE V and V

  5. Features of Computerized Procedure System of Shin-Kori unit 5 and 6

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Nokyu; Jung, Yeonsub; Sung, Chanho [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The Computerized Procedure System (CPS) is one of the Man Machine Interface (MMI) resources of Main Control Room (MCR) of the Advanced Power Reactor 1400 (APR1400). The CPS has been continuously improved since it was installed in Shin-Kori unit 3 and 4. The Korea Hydro Nuclear Power Central Research Institute (KHNP CRI) has found the points of improvement of CPS through CPS centered Human Factors Engineering Verification and Validation (HFE V and V) and Operating Experience Review (OER) of reference power plant. This paper shows the main features of CPS of Shin-Kori 5 and 6 unit. This paper shows the main features of CPS of Shin-Kori 5 and 6. These are some of improvements of CPS. This prototype of CPS currently is implementing in CRI. The respective function can be more detailed after testing the prototype. These features will be applied to Shin-Kori 5 and 6 CPS after HFE V and V.

  6. A Comparison of Item Selection Procedures Using Different Ability Estimation Methods in Computerized Adaptive Testing Based on the Generalized Partial Credit Model

    Science.gov (United States)

    Ho, Tsung-Han

    2010-01-01

    Computerized adaptive testing (CAT) provides a highly efficient alternative to the paper-and-pencil test. By selecting items that match examinees' ability levels, CAT not only can shorten test length and administration time but it can also increase measurement precision and reduce measurement error. In CAT, maximum information (MI) is the most…

  7. Comparison, with regard to safety, between a hard-wired reactor protection system and a computerized protection system. Pt. 1

    International Nuclear Information System (INIS)

    Buettner, W.E.

    1976-07-01

    The study compares a conventional hard-wired dynamic reactor protection system with a computerized protection system. In the comparison, only the unequivocally safety-oriented protection actions are considered. In the first part, the different structures of both systems and the method of verification for their functional safety will be described. In the second part, the mean unavailability in case of demand for both systems under defined conditions will be determined. (orig.) [de

  8. Development of a computerized tomographic system based on the FAN-BEAM technique

    International Nuclear Information System (INIS)

    Junqueira, M.M.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory, at COPPE/UFRJ, concentrates its researches in the development of computerized tomographic systems, looking for applications in industrial and medical non destructive analysing techniques. In this work we have projected and constructed a tomographic prototype, based on the FAN-BEAM technique for irradiating the object under analysis. An algorithm previously developed to analyse parallel beams, was modified and adapted to the FAN-BEAM geometry. (Author) [pt

  9. Computerized reactor protection and safety related systems in nuclear power plants. Proceedings of a specialists' meeting. Working material

    International Nuclear Information System (INIS)

    1998-01-01

    Though the majority of existing control and protection systems in nuclear power plants use old analogue technology and design philosophy, the use of computers in safety and safety related systems is becoming a current practice. The Specialists Meeting on ''Computerized Reactor Protection and Safety Related Systems in Nuclear Power Plants'' was organized by IAEA (jointly by the Division of Nuclear Power and the Fuel Cycle and the Division of Nuclear Installation Safety), in co-operation with Paks Nuclear Power Plant in Hungary and was held from 27-29 October 1997 in Budapest, Hungary. The meeting focused on computerized safety systems under refurbishment, software reliability issues, licensing experiences and experiences in implemented computerized safety and safety related systems. Within a meeting programme a technical visit to Paks NPP was organized. The objective of the meeting was to provide an international forum for the presentation and discussion on R and D, in-plant experiences in I and C important to safety, backfits and arguments for and reservations against the digital safety systems. The meeting was attended by 70 participants from 16 countries representing NPPs and utility organizations, design/engineering, research and development, and regulatory organizations. In the course of 4 sessions 25 technical presentations were made. The present volume contains the papers presented by national delegates and the conclusions drawn from the final general discussion

  10. Reliability and Validity of the Computerized Revised Token Test: Comparison of Reading and Listening Versions in Persons with and without Aphasia

    Science.gov (United States)

    McNeil, Malcolm R.; Pratt, Sheila R.; Szuminsky, Neil; Sung, Jee Eun; Fossett, Tepanta R. D.; Fassbinder, Wiltrud; Lim, Kyoung Yuel

    2015-01-01

    Purpose: This study assessed the reliability and validity of intermodality associations and differences in persons with aphasia (PWA) and healthy controls (HC) on a computerized listening and 3 reading versions of the Revised Token Test (RTT; McNeil & Prescott, 1978). Method: Thirty PWA and 30 HC completed the test versions, including a…

  11. Establishment of computerized support system for the assessment of radiation exposure in a nuclear emergency

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hui; Lee, Yeong Bok; Kim, Eun Han; Seo, Kyeong Seok; Hwang, Won Tae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, Byeong Woo [Sungkyunkwan Univ., Seoul (Korea, Republic of)

    1994-12-15

    For the development of a real-time dose assessment, the knowledge over several fields is necessary. For the establishment of the computerized support system for radiation dose assessment, the followings activities have been carried out in this first year. The first test operation of FADAS on HP workstation has been done by editing the basic modules which had been developed as a nuclear long-term project of Korea Atomic Energy Research Institute. The environmental information around the Kori site have been investigated and the information related to the emergency planning such as population density, road network, and socio-environmental data have been displayed on the computer screen. For the automatic control of the basic modules of FADAS, a first-step control program has been organized.

  12. Using the Five-Level Taiwan Triage and Acuity Scale Computerized System: Factors in Decision Making by Emergency Department Triage Nurses.

    Science.gov (United States)

    Chang, Wen; Liu, Hsueh-Erh; Goopy, Suzanne; Chen, Li-Chin; Chen, Hsiao-Jung; Han, Chin-Yen

    2017-10-01

    Triage classifies and prioritizes patients' care based on the acuity of the illness in emergency departments (EDs). In Taiwan, the five-level Taiwan Triage and Acuity Scale (TTAS) computerized system was implemented nationally in 2010. The purpose of this study was to understand which factors affect decision-making practices of triage nurses in the light of the implementation of the new TTAS tool and computerized system. The qualitative data were collected by in-depth interviews. Data saturation was reached with 16 participants. Content analysis was used. The results demonstrated that the factors affecting nurses' decision making in the light of the newly implemented computerized system sit within three main categories: external environmental, patients' health status, and nurses' experiences. This study suggests ensuring the patient's privacy while attending the triage desk, improving the critical thinking of triage nurses, and strengthening the public's understanding of the ED visits. These will make ED triage more efficient.

  13. Design and development of computerized local and overall country's environmental data analysis network system

    International Nuclear Information System (INIS)

    Kim, Chang Gyu; Kang, Jong Gyu; Han, H.; Han, J. S.; Lee, Y. D.; Lee, S. R.; Kang, D. J.; Cho, Y. G.; Yun, S. H.

    2001-03-01

    In this development, we designed a integrated database for efficient data processing of radiation-environment data and developed the CLEAN (Computerized Local and overall country's Environmental data Analysis Network) system. The CLEAN system consists of local radiation-environment network, data analysis system, data open system. We developed the CLEAN system focused on building an integrated database, a data mart, and a CLEAN web site. It is expected that the developed system, which organizes the information related to environmental radiation data systematically, can be utilize for the accurate interpretation, analysis and evaluation

  14. Development of a generic, computerized nuclear material accountability system: NucMAS

    International Nuclear Information System (INIS)

    Cornell, M.D.; O'Leary, J.M.

    1987-01-01

    The application NucMAS provides basic computerized accountability functions for the Savannah River Plant (SRP) Separations Department Material Balance Areas (MBA's). These functions include data entry, data management, calculations, and report generation. NucMAS can be used both for routine reporting to the SRP central Material Control and Accounting (MC and A) system and for rapid ad hoc queries in emergency situations. The system is designed to work with any process handling one or more of the 17 accountable nuclear materials specified by the Department of Energy (DOE). It relies on user-supplied configuration data to drive data prompts, report headings, data validations, and calculations

  15. Barriers to implementation of a computerized decision support system for depression: an observational report on lessons learned in "real world" clinical settings

    Directory of Open Access Journals (Sweden)

    Sunderajan Prabha

    2009-01-01

    Full Text Available Abstract Background Despite wide promotion, clinical practice guidelines have had limited effect in changing physician behavior. Effective implementation strategies to date have included: multifaceted interventions involving audit and feedback, local consensus processes, marketing; reminder systems, either manual or computerized; and interactive educational meetings. In addition, there is now growing evidence that contextual factors affecting implementation must be addressed such as organizational support (leadership procedures and resources for the change and strategies to implement and maintain new systems. Methods To examine the feasibility and effectiveness of implementation of a computerized decision support system for depression (CDSS-D in routine public mental health care in Texas, fifteen study clinicians (thirteen physicians and two advanced nurse practitioners participated across five sites, accruing over 300 outpatient visits on 168 patients. Results Issues regarding computer literacy and hardware/software requirements were identified as initial barriers. Clinicians also reported concerns about negative impact on workflow and the potential need for duplication during the transition from paper to electronic systems of medical record keeping. Conclusion The following narrative report based on observations obtained during the initial testing and use of a CDSS-D in clinical settings further emphasizes the importance of taking into account organizational factors when planning implementation of evidence-based guidelines or decision support within a system.

  16. EMERIS: an advanced information system for a materials testing reactor

    International Nuclear Information System (INIS)

    Adorjan, F.; Buerger, L.; Lux, I.; Mesko, L.; Szabo, K.; Vegh, J.; Ivanov, V.V.; Mozhaev, A.A.; Yakovlev, V.V.

    1990-06-01

    The basic features of the Materials Testing Reactor of IAE, Moscow (MR) Information System (EMERIS) are outlined. The purpose of the system is to support reactor and experimental test loop operators by a flexible, fully computerized and user-friendly tool for the aquisition, analysis, archivation and presentation of data obtained during operation of the experimental facility. High availability of EMERIS services is ensured by redundant hardware and software components, and by automatic configuration procedure. A novel software feature of the system is the automatic Disturbance Analysis package, which is aimed to discover primary causes of irregularities occurred in the technology. (author) 2 refs.; 2 figs

  17. Effects of computerized decision support systems on blood glucose regulation in critically ill surgical patients.

    Science.gov (United States)

    Fogel, Sandy L; Baker, Christopher C

    2013-04-01

    The use of computerized decision support systems (CDSS) in glucose control for critically ill surgical patients has been reported in both diabetic and nondiabetic patients. Prospective studies evaluating its effect on glucose control are, however, lacking. The objective of this study was to evaluate patient-specific computerized IV insulin dosing on blood glucose levels (BGLs) by comparing patients treated pre-CDSS with those treated post-CDSS. A prospective study was performed in 4 surgical ICUs and 1 progressive care unit comparing patient data pre- and post-implementation of CDSS. The primary outcomes measures were the impact of the CDSS on glycemic control in this population and on reducing the incidence of severe hypoglycemia. Data on 1,682 patient admissions were evaluated, which corresponded to 73,290 BGLs post-CDSS compared with 44,972 BGLs pre-CDSS. The percentage of hyperglycemic events improved, with BGLs of >150 mg/dL decreasing by 50% compared with 6-month historical controls during the 18-month study period from July 2010 through December 2011. This was true for all 5 units individually (p < 0.0001, by one sample sign test). In addition, severe hypoglycemia (defined as BGL <40 mg/dL) decreased from 1% to 0.05% after implementing CDSS (p < 0.0001 by 2-sided binomial test). Patients whose BGLs were managed using CDSS were statistically significantly more likely to have a glucose reading under control (<150 mg/dL) than in the 6-month historical controls and to avoid serious hypoglycemia (p < 0.0001). Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  18. A study on the development of the computerized safety evaluation system of the motor operated valve

    International Nuclear Information System (INIS)

    Kim, J. C.; Park, S. G.; Lee, D. H.; Ahn, N. S.; Bae, H. J.; Hong, J. S.

    2001-01-01

    The MOVIDIK (Motor-Operated Valves Integrated Database and Information of KEPCO) system was developed to assist the design basis safety evaluation and to manage the overall data made by evaluation on the safety-related Motor-operated Valves(MOV) in the nuclear power plant. The huge amount of safety evaluation data of the MOV is being piled up as the safety evaluation work goes on. Much time and manpower was needed to do safety evaluation works without computerized system and it was not easy to obtain the statistic information from the evaluation data. The MOVIDIK will improve the efficiency of safety evaluation works and standardize the analysis process. But the some process which needs specific evaluation codes and engineering calculation by the specialists was not computerized. The MOVIDIK was developed by JAVA/JSP language known by the flexibility of language and the easiness of transplantation between operating systems. The Oracle 8i which is the world's most popular database was used for MOVIDIK database

  19. Development and application of computerized maintenance management system at a nuclear fuel cycle facilities

    International Nuclear Information System (INIS)

    Oh, Yon Woo; Kim, S. D.; Jang, K. D.; Kim, Y. G.

    2001-12-01

    In order to accomplish the purpose of research, it is the most important for the equipment to work well. The computerized maintenance management system proven by the case-studies can have an effect on the research and it can be one of the most major elements to assist the research at the research laboratory. To prevent the breakdown of the equipment at the research facility which can hinder the improvement of the research work, it is essential to maintain the equipment of facility without the sudden breakdown and to short the recovery time. If these elements such as the causes of the breakdown were well-managed and suvervised with care, this recovery time could be minimized. The aims of this research, therefore, are to introduce the development of the computerized maintenance management system and to apply it at the field in order to minimize the breakdown of the equipment and the recovery time and in order to perform the equipment maintenance service with the minimized expense and maximize the service efficiency through the planned management of the budget, the manpower and the service

  20. Replacement of the computerized control system at NPP under operation

    International Nuclear Information System (INIS)

    Ermolaev, A.D.; Rakitin, I.D.

    1985-01-01

    Reasons and preconditions for replacement of the computerized control systems (CCS) at NPP under operation are consi-- dered. Problems dealing with management of CCS replacement, maintenance of a new CCS as well as NPP personnel training for the new system maintenance are discussed. A necessity of NPP personnel participation in these works in order to adapt CCS to requirements of NPP operation personnel and to initiate the training process is underlined. Replacement of CCS at NPP under operation is associated, as a rule, with obsolescence of old systems not ensuring growing requirements to NPP workability and safety. Principles observed at CCS replacement are reduced, mainly, to the following; maximum utilizatian of existing equipment, metal strUctures, cables, instruments, power supplies, ventilation system minimum of construction works and new communications; the least change of acting panels and boxes; changes in control desks should be introduced on the basis of the analysis of operator actions '

  1. Computerized data base of the fundamental constants of nature

    International Nuclear Information System (INIS)

    Henry, E.A.; Hampel, V.E.

    1975-01-01

    Fifty-seven fundamental constants of nature were computerized from the up-to-date evaluations of E. R. Cohen and B. N. Taylor. The constants are annotated with regard to symbol, value, uncertainty, and scaling factor. This computerization is part of the scientific data base project of the Information Research Group at Lawrence Livermore Laboratory. The MASTER CONTROL data base management system is used. The computerized fundamental constants can be requested from the ERDA Computer Program Exchange and Information Center of the Argonne National Laboratory or from the National Technical Information Service of the U. S. Department of Commerce. This is the first of a series of releases on preparation of computerized scientific and technological data banks. The next release is a data bank of conversion factors for different units of measurements. 3 figures

  2. Radiodiagnostic system combining scintillation GKS-2 γ camera and SAORI-01 computerized unit

    International Nuclear Information System (INIS)

    Kalashnikov, S.D.; Mishchenko, S.V.; Chuprov, P.V.

    1986-01-01

    A medical radiodiagnostic system prising the GKS-2 scintillation gamma chamber and the on-line data processing system is described. The gamma chamber consists of a detector, a two-channel control console, a microprocessor system for correction of distortions,system of photographic recording of images from an oscilloscopic display, a digital display-monitor and 6 accessiory collimators with trucks. GKS-2 has the increased spatial resolution, fast response and image homogeneity. Application of GKS-2 together with the SAORI-01 specialized on-line system,comprising the measuring computerized system, the colour-graphic display controller the polarizer photographic recording device for scanning image from the display screen and a system of base software, expands substantially diagnostic possibilities of equipment

  3. Experimental studies of computerized procedures and team size in nuclear power plant operations

    International Nuclear Information System (INIS)

    Huang, F.-H.; Hwang, S.-L.

    2009-01-01

    The operation of a nuclear power plant is so complex that it requires teamwork. To support team performance, a system need to provide all team members integrated information displays as well as decision aids (e.g., computerized procedures). Two experiments were conducted to investigate the effects of computerized procedures and team size on operating performance. Forty-five participants were involved in the experiments. Each participant executed decision and action tasks to deal with alarm signals, while detecting occasional system errors in the interface. Results showed that effects of computerized procedures were significant on various performance indicators, such as operation time, operation errors, and learning effect, and that two operators would be a satisfactory size in the teamwork system providing computerized procedures

  4. Computerized materials protection, control, and accountability

    International Nuclear Information System (INIS)

    Whiteson, R.; Seitz, S.; Landry, R.P.; Hadden, M.L.; Painter, J.A.

    1997-01-01

    The proliferation of nuclear weapons, along with the technical knowledge and materials needed to make these weapons, is an enduring problem of international urgency. Current international nuclear nonproliferation efforts are aimed at deterring, detecting, and responding to proliferation of weapons of mass destruction. These safeguards efforts are being implemented by applying preeminent science and technology to the management and control of nuclear materials. By strengthening systems of nuclear material protection, control, and accountability (MPC and A), one can reduce the threat of nuclear weapons proliferation. Two major programs of international cooperation are now underway to achieve this goal. The first is between the US Department of Energy (DOE) and the Institutes of the Russian Federation (Laboratory-to-Laboratory Program), and the second is between the US Government and Governments of the former Soviet Republics (Government-to-Government Program). As part of these programs, the DOE is working with facilities to assist them in implementing computerized MPC and A systems. This work is a collaboration between computer scientists and safeguards experts in both the US and the new Republics. The US is making available technology and expertise to enable Russian experts to build on computerized MPC and A software developed in the US. This paper describes the joint efforts of these international teams to develop sophisticated computerized MPC and A systems using modern computer hardware and software technology. These systems are being customized to meet the site-specific needs of each facility

  5. Survey of methods for improving operator acceptance of computerized aids

    International Nuclear Information System (INIS)

    Frey, P.R.; Kisner, R.A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room

  6. Survey of methods for improving operator acceptance of computerized aids

    Energy Technology Data Exchange (ETDEWEB)

    Frey, P. R.; Kisner, R. A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room.

  7. Build Your Own Inventory System. Annual Cost: $100.00 (Approximate). Fixed Assets, Materials and Supplies. The Practical Elements for a Computerized, Continuing Inventory System in Schools and Use in Determining a Measure for Instructional Cost.

    Science.gov (United States)

    Payne, Arnold, Comp.

    This publication presents performance flow charts and other accompanying forms that are elements of an economical computerized continuing inventory system. The system described here is intended to serve school systems as an adequate fixed asset system and to provide a computerized inventory model that offers support for costs of future educational…

  8. Computerized Operator Support System – Phase II Development

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Thomas A.; Boring, Ronald L.; Lew, Roger T.; Thomas, Kenneth D.

    2015-02-01

    A computerized operator support system (COSS) prototype for nuclear control room process control is proposed and discussed. The COSS aids operators in addressing rapid plant upsets that would otherwise result in the shutdown of the power plant and interrupt electrical power generation, representing significant costs to the owning utility. In its current stage of development the prototype demonstrates four advanced functions operators can use to more efficiently monitor and control the plant. These advanced functions consist of: (1) a synthesized and intuitive high level overview display of system components and interrelations, (2) an enthalpy-based mathematical chemical and volume control system (CVCS) model to detect and diagnose component failures, (3) recommended strategies to mitigate component failure effects and return the plant back to pre-fault status, and (4) computer-based procedures to walk the operator through the recommended mitigation actions. The COSS was demonstrated to a group of operators and their feedback was collected. The operators responded positively to the COSS capabilities and features and indicated the system would be an effective operator aid. The operators also suggested several additional features and capabilities for the next iteration of development. Future versions of the COSS prototype will include additional plant systems, flexible computer-based procedure presentation formats, and support for simultaneous component fault diagnosis and dual fault synergistic mitigation action strategies to more efficiently arrest any plant upsets.

  9. Quality control of on-line calibration in computerized assessment

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1998-01-01

    In computerized adaptive testing, updating parameter estimates using adaptive testing data is often called online calibration. In this paper, how to evaluate whether the adaptive testing model used for online calibration fits the item response model used sufficiently is studied. Three approaches are

  10. Analysis of the percentage voids of test and field specimens using computerized tomography

    International Nuclear Information System (INIS)

    Braz, D.; Lopes, R.T.; Motta, L.M.G. da

    1999-01-01

    Computerized tomography has been an excellent tool of analysis of asphaltics mixtures, because it allows comparison of the quality and integrity of test and field specimens. It was required to detect and follow the evolution of cracks, when these mixtures were submitted to fatigue tests, and also helping to interpret the distribution of tensions and deformations which occur in the several types of solicitations imposed to the mixtures. Comparing the medium values of percentage voids obtained from tomographic images with the project's values, it can be observed that the values of test and field specimens for the wearing course are closer to the ones of the project than the ones of the binder. It can be verified that the wearing course specimens always present a distribution of the aggregate, and voids quite homogeneously in the whole profile of the sample, while the binder specimens show an accentuated differentiation of the same factors in the several heights of the sample. Therefore, when choosing a slice for tomography, these considerations should be taken into account

  11. The Use of Statistical Process Control-Charts for Person-Fit Analysis on Computerized Adaptive Testing. LSAC Research Report Series.

    Science.gov (United States)

    Meijer, Rob R.; van Krimpen-Stoop, Edith M. L. A.

    In this study a cumulative-sum (CUSUM) procedure from the theory of Statistical Process Control was modified and applied in the context of person-fit analysis in a computerized adaptive testing (CAT) environment. Six person-fit statistics were proposed using the CUSUM procedure, and three of them could be used to investigate the CAT in online test…

  12. Increasing Personal Value Congruence in Computerized Decision Support Using System Feedback

    Directory of Open Access Journals (Sweden)

    Bryan Hosack

    2014-02-01

    Full Text Available The Theory of Universals in Values (TUV, a reliable and validated conceptualization of personal values used in psychology, is used to examine the effect of system feedback delivered by a Decision Support System (DSS on personal values. The results indicate that value-based decision-making behavior can be influenced by DSS feedback to address value congruence in decision-making. User behavior was shown to follow the outcomes expected by operant theory when feedback was supportive and to follow the outcomes of reactance theory when feedback was challenging. This result suggests that practitioners and Information System (IS researchers should consider user values when designing computerized decision feedback to adjust a system’s design such that the potential user backlash is avoided or congruence between organizational and personal values is achieved.

  13. Development of a computerized operator support system for BWR power plant

    International Nuclear Information System (INIS)

    Monta, K.; Sekimizu, K.; Sato, N.; Araki, T.; Mori, N.

    1985-01-01

    A computerized operator support system for BWR power plant has been developed since 1980 supported by the Japanese government. The main functions of the systems are post trip operational guidance, disturbance analysis, standby system management, operational margin monitoring and control rod operational guidance. The former two functions aim at protection against incidents during operation of nuclear power plants and the latter three functions aim at their prevention. As the final stage of the development, these functions are combined with the plant supervision function and are organized as an advanced man-machine interface for BWR power plant. During the above process, operator task analyses are performed to enable synthesis of these support functions for right fit to operator tasks and to realize a hierarchical structure for CRT displays for right fit to operators cognitive needs. (author)

  14. Development and trial operation of a site-wide computerized material accounting system at Kurchatov Institute

    International Nuclear Information System (INIS)

    Roumiantsev, A.N.; Ostroumov, Y.A.; Yevstropov, A.V.

    1997-01-01

    Since August 1994 Kurchatov Institute in cooperation with several US Department of Energy Laboratories has been developing a site-wide computerized material accounting system for nuclear materials. In 1994 a prototype system was put into trial operation at two Kurchatov facilities. Evaluation of this prototype led to the development of a new computerized material accounting system named KI-MACS, which has been operational since 1996. This system is a site-wide local secure computer network with centralized database capable of dealing with strictly confidential data and performing near-real time accountancy. It utilizes a Microsoft Windows NT operating system with SQL Server and Visual Basic, and has a 'star'-like network architecture. KI-MACS is capable of dealing with materials in itemized and bulk form, and can perform statistical evaluations of measurements and material balance. KI-MACS is fully integrated with bar code equipment, electronic scales, gamma-ray spectrometers and an Active Well Coincidence Counter, thus providing almost on-line evaluation and utilization of results of measurements, item identification and accounting. At present KI-MACS is being used in Physical Inventory Taking at the Kurchatov Central Storage Facility, and by the end of 1997 will be installed at twelve Kurchatov nuclear facilities

  15. Development and trial operation of a site-wide computerized material accounting system at Kurchatov Institute

    Energy Technology Data Exchange (ETDEWEB)

    Roumiantsev, A.N.; Ostroumov, Y.A.; Yevstropov, A.V. [Kurchatov Institute RRC, Moscow (Russian Federation)] [and others

    1997-11-01

    Since August 1994 Kurchatov Institute in cooperation with several US Department of Energy Laboratories has been developing a site-wide computerized material accounting system for nuclear materials. In 1994 a prototype system was put into trial operation at two Kurchatov facilities. Evaluation of this prototype led to the development of a new computerized material accounting system named KI-MACS, which has been operational since 1996. This system is a site-wide local secure computer network with centralized database capable of dealing with strictly confidential data and performing near-real time accountancy. It utilizes a Microsoft Windows NT operating system with SQL Server and Visual Basic, and has a `star`-like network architecture. KI-MACS is capable of dealing with materials in itemized and bulk form, and can perform statistical evaluations of measurements and material balance. KI-MACS is fully integrated with bar code equipment, electronic scales, gamma-ray spectrometers and an Active Well Coincidence Counter, thus providing almost on-line evaluation and utilization of results of measurements, item identification and accounting. At present KI-MACS is being used in Physical Inventory Taking at the Kurchatov Central Storage Facility, and by the end of 1997 will be installed at twelve Kurchatov nuclear facilities.

  16. Computerized operator support system with new man-machine interface for BWR power plants

    International Nuclear Information System (INIS)

    Monta, K.; Naito, N.; Sugawara, M.; Sato, N.; Mori, N.; Tai, I.; Fukumoto, A.; Tsuchida, M.

    1984-01-01

    Improvement of the man-machine interface of nuclear power plants is an important contribution to the further enhancement of operational safety. In addition, recent advances in computer technology seem to offer the greatest opportunity to date for achieving improvement in the man-machine interface. The development of a computerized operator support system for BWRs has been undertaken since 1980 with the support of the Japanese Government. The conceptual design of this system is based on the role of the operators. The main functions are standby system management, disturbance analysis and post-trip operational guidance. The objective of the standby system management is to monitor the standby status of the engineered safety feature during normal operation to assure its proper functioning at the onset of emergency situations. The disturbance analysis system detects disturbances in the plant in their early stages and informs the plant operators about, for example, the cause of the disturbances, the plant status and possible propagations. Consequently, operators can take corrective actions to prevent unnecessary plant shutdown. The objective of the post trip operational guide is to support operators in diagnosis and corrective action after a plant trip. Its functions are to monitor the performance of the engineered safety feature, to identify the plant status and to guide the appropriate corrective action to achieve safe plant shutdown. The information from the computerized operator support system is supplied to operators through a colour CRT operator console. The authors have evaluated the performance of various new man-machine interfacing tools and proposed a new operator console design. A prototype system has been developed and verification/validation is proceeding with a BWR plant simulator. (author)

  17. Adjustment of the Kompleks Titan-2 monitoring computerized system at the Rovno NPP third unit

    International Nuclear Information System (INIS)

    Zigaev, B.P.

    1987-01-01

    Information signal origin and processing processes in the monitoring computerized system 'Komplex Titan-2' at the Rovno NPP third unit are considered. The system exercises control over the following production equipment parameters: the state of keys of control of lock fittings, mechanisms, regulators, reserve mechanism automatic shut-down circuit; the state of lock fittings, mechanisms, regulators, reserve mechanism automated switching on; parameter deviation from permissible values; interlock operation; protection system state; the state of autonomous units and devices

  18. Potential of Computerized Maintenance Management System in Facilities Management

    Directory of Open Access Journals (Sweden)

    Noor Farisya Azahar

    2014-07-01

    Full Text Available For some time it has been clear that managing buildings or estates has been carried out in the context of what has become known as facilities management. British Institute of Facilities Management defined facilities management is the integration of multi-disciplinary activities within the built environment and the management of their impact upon people and the workplace. Effective facilities management is vital to the success of an organisation by contributing to the delivery of its strategic and operational objectives. Maintenance of buildings should be given serious attention before (stage design, during and after a building is completed. But total involvement in building maintenance is after the building is completed and during its operations. Residents of and property owners require their building to look attractive, durable and have a peaceful indoor environment and efficient. The objective of the maintenance management system is to stream line the vast maintenance information system to improve the productivity of an industrial plant. a good maintenance management system makes equipment and facilities available. This paper will discuss the fundamental steps of maintenance management program and Computerized Maintenance Management System (CMMS

  19. Development and validation of the computerized family relations

    NARCIS (Netherlands)

    Skoczen, I.; Cieciuch, J.; Oud, J.H.L.; Welzen, K.F.

    2015-01-01

    The aim of the present study was to develop and investigate the psychometric properties of the Computerized Family Relations Test (CFRT) for children. This test assesses the quality of family relationships with the mother and father from a child's perspective. The CFRT consists of six scales

  20. Item response theory, computerized adaptive testing, and PROMIS: assessment of physical function.

    Science.gov (United States)

    Fries, James F; Witter, James; Rose, Matthias; Cella, David; Khanna, Dinesh; Morgan-DeWitt, Esi

    2014-01-01

    Patient-reported outcome (PRO) questionnaires record health information directly from research participants because observers may not accurately represent the patient perspective. Patient-reported Outcomes Measurement Information System (PROMIS) is a US National Institutes of Health cooperative group charged with bringing PRO to a new level of precision and standardization across diseases by item development and use of item response theory (IRT). With IRT methods, improved items are calibrated on an underlying concept to form an item bank for a "domain" such as physical function (PF). The most informative items can be combined to construct efficient "instruments" such as 10-item or 20-item PF static forms. Each item is calibrated on the basis of the probability that a given person will respond at a given level, and the ability of the item to discriminate people from one another. Tailored forms may cover any desired level of the domain being measured. Computerized adaptive testing (CAT) selects the best items to sharpen the estimate of a person's functional ability, based on prior responses to earlier questions. PROMIS item banks have been improved with experience from several thousand items, and are calibrated on over 21,000 respondents. In areas tested to date, PROMIS PF instruments are superior or equal to Health Assessment Questionnaire and Medical Outcome Study Short Form-36 Survey legacy instruments in clarity, translatability, patient importance, reliability, and sensitivity to change. Precise measures, such as PROMIS, efficiently incorporate patient self-report of health into research, potentially reducing research cost by lowering sample size requirements. The advent of routine IRT applications has the potential to transform PRO measurement.

  1. Computerized three-dimensional treatment planning system utilizing interactive colour graphics

    Energy Technology Data Exchange (ETDEWEB)

    McShan, D L; Silverman, A; Lanza, D M; Reinstein, L E; Glicksman, A S [Rhode Island Hospital (US). Dept. of Radiation Oncology

    1979-06-01

    A new computerized radiation treatment planning system has been developed to aid in three-dimensional treatment planning. Using interactive colour graphics in conjunction with a PDP 11/45 computer, the system can take multiple transverse contours and construct a perspective display of the treatment region showing organ surfaces as well as cross-sectional contours. With interactively selected orientations, the display allows easy perception of the relative positioning of the treatment volume and the neighbouring anatomy. For external beam treatment planning, interactive computer simulation is used to select diaphragm sizes which best conform to the target area while avoiding sensitive structures. Dose calculations for the selected beams are carried out on multiple transverse planes. The calculational planes and surfaces are displayed in perspective with radiation dosage displayed in an interactively manipulated colour display. Altogether the system provides an easy assessment of the volume to be irradiated, interactive selection of optimal arrangements of treatment fields and a means of visualizing and evaluating the resulting dose distributions.

  2. Cognitive task analysis and the design of computerized operator aids

    International Nuclear Information System (INIS)

    Andersson, H.

    1985-01-01

    The new technological possibilities have led to the initiation of many projects for the design and evaluation of computerized operator support systems to be implemented in nuclear power plant control rooms. A typical finding so far has been that operators often have a positive attitude towards such systems but still don't use them very much, mostly because they find almost the same information on the conventional control boards which they are accustomed to use. Still, however, there is a widely shared belief that conventional control rooms have short-comings that make the use of computerized aids necessary. One reason for the limited success so far is that the new systems often are poorly integrated with the existing conventional instrumentation and with the working procedures. The reluctance to use new computer based aids, despite their nice features, is therefore probably caused by an inadequate task analysis made prior to the design of these computerized operator support systems

  3. An Item Response Theory-Based, Computerized Adaptive Testing Version of the MacArthur-Bates Communicative Development Inventory: Words & Sentences (CDI:WS)

    Science.gov (United States)

    Makransky, Guido; Dale, Philip S.; Havmose, Philip; Bleses, Dorthe

    2016-01-01

    Purpose: This study investigated the feasibility and potential validity of an item response theory (IRT)-based computerized adaptive testing (CAT) version of the MacArthur-Bates Communicative Development Inventory: Words & Sentences (CDI:WS; Fenson et al., 2007) vocabulary checklist, with the objective of reducing length while maintaining…

  4. Pain assessment by children and adolescents during intraosseous anaesthesia using a computerized system (QuickSleeper).

    Science.gov (United States)

    Sixou, Jean-Louis; Marie-Cousin, Alexia; Huet, Adeline; Hingant, Bernard; Robert, Jean-Claude

    2009-09-01

    Intraosseous (IO) anaesthesia has been shown to be effective in children. However, the pain associated with anaesthetic injections, and its acceptance by children, have never been studied. The aim of this study was to assess the pain associated with the IO injection of 4% articaine with 1 : 200 000 epinephrine using the computerized QuickSleeper' system in a population of children and adolescents. IO anaesthesia was performed on patients aged 10.4 +/- 2.6 years of age. The patients assessed their pain on a faces pain scale (FPS) and on a visual analogue scale (VAS). The operators were also asked to assess signs of patient pain/discomfort. No pain or mild discomfort was reported by, respectively, 81.8% (FPS) and 83.9% (VAS) of the patients. Some 58.9% of children with previous experience of dental anaesthesia reported that computerized IO anaesthesia was more comfortable than traditional infiltration methods. Operators noted signs of discomfort during penetration and injection in 18.3% and 25.3% of the patients, respectively. This study showed that the majority of children reported no pain or mild pain when anaesthetic was administered by computerized needle rotation and solution deposition. This technique holds promise for use by trained paediatric dentists.

  5. Development of a simple computerized torsion test to quantify subjective ocular torsion.

    Science.gov (United States)

    Kim, Y D; Yang, H K; Hwang, J-M

    2017-11-01

    PurposeThe double Maddox-rod test (DMRT) and Lancaster red-green test (LRGT) are the most widely used tests worldwide to assess subjective ocular torsion. However, these tests require equipment and the quantified results of ocular torsion are only provided in rough values. Here we developed a novel computerized torsion test (CTT) for individual assessment of subjective ocular torsion and validated the reliability and accuracy of the test compared with those of the DMRT and LRGT.MethodsA total of 30 patients with cyclovertical strabismus and 30 controls were recruited. The CTT was designed using Microsoft Office PowerPoint. Subjects wore red-green filter spectacles and viewed gradually tilted red and cyan lines on an LCD monitor and pressed the keyboard to go through the slides, until both lines seemed parallel. All subjects underwent the CTT, DMRT, and LRGT. Intraclass correlation coefficients and Bland-Altman plots were analyzed to assess the acceptability of the CTT compared with that of the DMRT.ResultsBoth the DMRT and CTT showed no significant test-retest differences in the strabismus and control groups. The DMRT and CTT results demonstrated an acceptable agreement. The reliability of the CTT was better than that of the DMRT. The LRGT showed low sensitivity for the detection of ocular torsion compared with the DMRT (40.0%) and CTT (39.1%).ConclusionOur results suggest that the assessment of subjective ocular torsion using the CTT based on PowerPoint software is simple, reproducible, and accurate and can be applied in clinical practice.

  6. Development and application of computerized maintenance management system at a nuclear fuel cycle facilities

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Yon Woo; Kim, S D; Jang, K D; Kim, Y G

    2001-12-01

    In order to accomplish the purpose of research, it is the most important for the equipment to work well. The computerized maintenance management system proven by the case-studies can have an effect on the research and it can be one of the most major elements to assist the research at the research laboratory. To prevent the breakdown of the equipment at the research facility which can hinder the improvement of the research work, it is essential to maintain the equipment of facility without the sudden breakdown and to short the recovery time. If these elements such as the causes of the breakdown were well-managed and suvervised with care, this recovery time could be minimized. The aims of this research, therefore, are to introduce the development of the computerized maintenance management system and to apply it at the field in order to minimize the breakdown of the equipment and the recovery time and in order to perform the equipment maintenance service with the minimized expense and maximize the service efficiency through the planned management of the budget, the manpower and the service00.

  7. Computerized health physics record system at a Canadian fabrication facility

    International Nuclear Information System (INIS)

    Thind, K.S.

    1984-01-01

    This poster session will describe the types of Health Physics data input into a Hewlett-Packard 3000 computer. The Health Physics data base at this facility includes the following: employee hours data, airborne uranium concentrations, external dosemetry (badge readings), internal dosemetry (bioassay) and environmental health physics (stack sample results) data. It will describe the types of outputs achievable in the form of various reports, such as: individual employee health physics report for a given period, a general health physics summary report for a given period, individual urinalysis report, local air concentration report and graphs. The use of this computerized health physics record system in the overall radiation protection program at this facility is discussed

  8. Computerized techniques for collecting the radioprotection data

    International Nuclear Information System (INIS)

    Cenusa, V.; Valeca, S.; Guta, C.; Talpalariu, C.; Stoica, V.

    2016-01-01

    An important component of a computerized radioprotection system is the module for the collection of the radioprotection data. The data collection can be made automatically from the measurement equipment or manually by the operators after they read the values measured by the mobile devices. Database systems are used for storing the data, they offer higher performances, more efficient data organization, ensure data integrity and controlled access to the data into a multiuser environment. The experimental program for the automatic collection of the remote data transfers periodically, at programmable time intervals, data files from the fixed radiation monitoring stations to a centralized system for radioprotection data. For this is used the File Transfer Protocol (FTP). A Radiation Monitoring Equipment designed and assembled in the Electronics Department of ICN Pitesti was used as a data source for the testing of the experimental programs. (authors)

  9. Report of the National Sub-Committee to the Interprovincial Standards Program Coordinating Committee on the Interprovincial Computerized Examination Management System=Rapport du Sous-Comite National presente au Comite de Coordination du Programme de Normes Interprovincials sur le systeme de gestion des examens informatises interprovinciaux.

    Science.gov (United States)

    New Brunswick Dept. of Advanced Education and Training, Fredericton. Interprovincial Standards Program Coordinating Committee.

    In January 1985, Employment and Immigration Canada funded a pilot project in New Brunswick for the development and testing of an Interprovincial Computerized Examination Management (ICEM) System. The resulting system is comprised of a dual interprovincial and provincial item bank facility, a software component offering the option of computerized…

  10. Computerized medical convocations

    International Nuclear Information System (INIS)

    Roche, Annie; Gilbert, Jean-Francois; Chiadot, Pierre; Vanzetto, Rene; Darnault, Jean

    1969-06-01

    Thanks to a close collaboration between the Medical and Social department and the Numerical Calculation Laboratory, a computerized convocation system has been implemented to reduce the administrative workload and to introduce more rigor in medical management, patient historical background and statistics. This work comprises: - a preliminary study of the data generating medical convocations and the related practical requirements; - the programming work according to these data; - the realisation of the mechano-graphical file covering the overall personnel [fr

  11. Computerized reactor monitor and control for nuclear reactors

    International Nuclear Information System (INIS)

    Buerger, L.

    1982-01-01

    The analysis of a computerized process control system developed by Transelektro-KFKI-Videoton (Hangary) for a twenty-year-old research reactor in Budapest and or a new one in Tajura (Libya) is given. The paper describes the computer hardware (R-10) and the implemented software (PROCESS-24K) as well as their applications at nuclear reactors. The computer program provides for man-machine communication, data acquisition and processing, trend and alarm analysis, the control of the reactor power, reactor physical calculations and additional operational functions. The reliability and the possible further development of the computerized systems which are suitable for application at reactors of different design are also discussed. (Sz.J.)

  12. Computerized Proof Techniques for Undergraduates

    Science.gov (United States)

    Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu

    2012-01-01

    The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete…

  13. Working Memory Training in Children with Mild Intellectual Disability, Through Designed Computerized Program

    Directory of Open Access Journals (Sweden)

    Mona Delavarian

    2015-12-01

    Full Text Available Objectives: The aim of this research is designing a computerized program, in game format, for working memory training in mild intellectual disabled children. Methods: 24 students participated as test and control groups. The auditory and visual-spatial WM were assessed by primary test, which included computerized Wechsler numerical forward and backward sub- tests, and secondary tests, which contained three parts: dual visual-spatial test, auditory test, and a one-syllable word recalling test. Results: The results showed significant differnces between working memory capacity in the intellectually disabled children and normal ones (P-value<0.00001. After using the computerized working memory training, Visual-spatial WM, auditory WM, and speaking were improved in the trained group. The mentioned four tests showed significant differences between pre-test and post-test. The trained group showed more improvements in forward tasks. The trained participant’s processing speed increased with training. Discussion: According to the results, comprehensive human-computer interfaces and the aplication of computer in children training, especially in traing of intellectual disabled children with impairements in visual and auditory perceptions, could be more effective and vaulable.

  14. Development of an instrument to measure health center (HC) personnel's computer use, knowledge and functionality demand for HC computerized information system in Thailand.

    Science.gov (United States)

    Kijsanayotin, Boonchai; Pannarunothai, Supasit; Speedie, Stuart

    2005-01-01

    Knowledge about socio-technical aspects of information technology (IT) is vital for the success of health IT projects. The Thailand health administration anticipates using health IT to support the recently implemented national universal health care system. However, the national knowledge associate with the socio-technical aspects of health IT has not been studied in Thailand. A survey instrument measuring Thai health center (HC) personnel's computer use, basic IT knowledge and HC computerized information system functionality needs was developed. The instrument reveals acceptable test-retest reliability and reasonable internal consistency of the measures. The future nation-wide demonstration study will benefit from this study.

  15. Reflecting on the ethical administration of computerized medical records

    Science.gov (United States)

    Collmann, Jeff R.

    1995-05-01

    This presentation examines the ethical issues raised by computerized image management and communication systems (IMAC), the ethical principals that should guide development of policies, procedures and practices for IMACS systems, and who should be involved in developing a hospital's approach to these issues. The ready access of computerized records creates special hazards of which hospitals must beware. Hospitals must maintain confidentiality of patient's records while making records available to authorized users as efficiently as possible. The general conditions of contemporary health care undermine protecting the confidentiality of patient record. Patients may not provide health care institutions with information about themselves under conditions of informed consent. The field of information science must design sophisticated systems of computer security that stratify access, create audit trails on data changes and system use, safeguard patient data from corruption, and protect the databases from outside invasion. Radiology professionals must both work with information science experts in their own hospitals to create institutional safeguards and include the adequacy of security measures as a criterion for evaluating PACS systems. New policies and procedures on maintaining computerized patient records must be developed that obligate all members of the health care staff, not just care givers. Patients must be informed about the existence of computerized medical records, the rules and practices that govern their dissemination and given the opportunity to give or withhold consent for their use. Departmental and hospital policies on confidentiality should be reviewed to determine if revisions are necessary to manage computer-based records. Well developed discussions of the ethical principles and administrative policies on confidentiality and informed consent and of the risks posed by computer-based patient records systems should be included in initial and continuing

  16. Computerized detection of acute ischemic stroke in brain computed tomography images

    International Nuclear Information System (INIS)

    Nagashima, Hiroyuki; Shiraishi, Akihisa; Harakawa, Tetsumi; Shiraishi, Junji; Doi, Kunio; Sunaga, Shinichi

    2009-01-01

    The interpretation of acute ischemic stroke (AIS) in computed tomography (CT) images is a very difficult challenge for radiologists. To assist radiologists in CT image interpretation, we have developed a computerized method for the detection of AIS using 100 training cases and 60 testing cases. In our computerized method, the inclination of the isotropic brain CT volume data is corrected by rotation and shifting. The subtraction data for the contralateral volume is then derived by subtraction from the mirrored (right-left reversed) volume data. Initial candidates suspected to have experienced AIS were identified using multiple-thresholding and filtering techniques. Twenty-one image features of these candidates were extracted and applied to a rule-based test to identify final candidates for AIS. The detection sensitivity values for the training cases and for the testing cases were 95.0% with 3.1 false positives per case and 85.7% with 3.4 false positives per case, respectively. Our computerized method showed good performance in the detection of AIS by CT and is expected to be useful in decision-making by radiologists. (author)

  17. A formal design verification and validation on the human factors of a computerized information system in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Yong Hee; Park, Jae Chang; Cheon, Se Woo; Jung, Kwang Tae; Baek, Seung Min; Han, Seung; Park, Hee Suk; Son, Ki Chang; Kim, Jung Man; Jung Yung Woo

    1999-11-01

    This report describe a technical transfer under the title of ''A formal design verification and validation on the human factors of a computerized information system in nuclear power plants''. Human factors requirements for the information system designs are extracted from various regulatory and industrial standards and guidelines, and interpreted into a more specific procedures and checklists for verifying the satisfaction of those requirements. A formalized implementation plan is established for human factors verification and validation of a computerized information system in nuclear power plants. Additionally, a Computer support system, named as DIMS-web (design Issue Management System), is developed based upon web internet environment so as to enhance the implementation of the human factors activities. DIMS-Web has three maine functions: supporting requirements review, tracking design issues, and management if issues screening evaluation. DIMS-Web shows its benefits in practice through a trial application to the design review of CFMS for YGN nuclear unit 5 and 6. (author)

  18. A formal design verification and validation on the human factors of a computerized information system in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Park, Jae Chang; Cheon, Se Woo; Jung, Kwang Tae; Baek, Seung Min; Han, Seung; Park, Hee Suk; Son, Ki Chang; Kim, Jung Man; Jung Yung Woo

    1999-11-01

    This report describe a technical transfer under the title of ''A formal design verification and validation on the human factors of a computerized information system in nuclear power plants''. Human factors requirements for the information system designs are extracted from various regulatory and industrial standards and guidelines, and interpreted into a more specific procedures and checklists for verifying the satisfaction of those requirements. A formalized implementation plan is established for human factors verification and validation of a computerized information system in nuclear power plants. Additionally, a Computer support system, named as DIMS-web (design Issue Management System), is developed based upon web internet environment so as to enhance the implementation of the human factors activities. DIMS-Web has three maine functions: supporting requirements review, tracking design issues, and management if issues screening evaluation. DIMS-Web shows its benefits in practice through a trial application to the design review of CFMS for YGN nuclear unit 5 and 6. (author)

  19. Feasibility of a computerized intervention for offenders with substance use disorders: a research note.

    Science.gov (United States)

    Chaple, Michael; Sacks, Stanley; McKendrick, Karen; Marsch, Lisa A; Belenko, Steven; Leukefeld, Carl; Prendergast, Michael; French, Michael

    2014-01-01

    Despite evidence that treatment is effective in reducing recidivism among inmates with substance use problems, scarce resources mean that few of those in need of treatment actually receive it. Computerized substance abuse interventions could be used to expand access to treatment in prisons without placing an undue burden on resources. The major aim of the study was to compare treatment conditions in terms of their service utilization, skills acquisition, and treatment satisfaction. The study recruited men and women with substance use disorders from 10 prisons in 4 states. In an open label clinical trial, 494 subjects were randomly assigned either to the Experimental condition, a computerized drug treatment intervention, the Therapeutic Education System (TES; n  = 249), or to the Control condition, Standard Care ( n  = 245). Chi-square tests compared groups on categorical variables and independent samples t tests were used for interval level continuous variables. Initial evidence demonstrated: (1) comparable group rates of session attendance and high rates of TES module completion for experimental subjects; (2) comparable group gains in the development of coping skills; and (3) a more favorable view of TES than of Standard Care . Collectively, these results show that a computerized intervention, such as TES, can be implemented successfully in prison. Given the barriers to the delivery of substance abuse treatment typically encountered in correctional settings, computerized interventions have the potential to fill a significant treatment gap and are particularly well suited to inmates with mild to moderate substance use disorders who often are not treated.

  20. Computerized photogrammetry used to calculate the brow position index.

    Science.gov (United States)

    Naif-de-Andrade, Naif Thadeu; Hochman, Bernardo; Naif-de-Andrade, Camila Zirlis; Ferreira, Lydia Masako

    2012-10-01

    The orbital region is of vital importance to facial expression. Brow ptosis, besides having an impact on facial harmony, is a sign of aging. Various surgical techniques have been developed to increase the efficacy of brow-lift surgery. However, no consensus method exists for an objective measurement of the eyebrow position due to the curvature of the face. Therefore, this study aimed to establish a method for measuring the eyebrow position using computerized photogrammetry. For this study, 20 orbital regions of 10 volunteers were measured by direct anthropometry using a digital caliper and by indirect anthropometry (computerized photogrammetry) using standardized digital photographs. Lines, points, and distances were defined based on the position of the anthropometric landmarks endocanthion and exocanthion and then used to calculate the brow position index (BPI). Statistical analysis was performed using Student's t test with a significance level of 5 %. The BPI values obtained by computerized photogrammetric measurements did not differ significantly from those obtained by direct anthropometric measurements (p > 0.05). The mean BPI was 84.89 ± 10.30 for the computerized photogrammetric measurements and 85.27 ± 10.67 for the direct anthropometric measurements. The BPI defined in this study and obtained by computerized photogrammetry is a reproducible and efficient method for measuring the eyebrow position. This journal requires that authors assign a level of evidence to each article.

  1. Design and development of computerized local and overall country's environmental data analysis network system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Gyu; Kang, Jong Gyu; Han, H.; Han, J. S.; Lee, Y. D.; Lee, S. R.; Kang, D. J.; Cho, Y. G.; Yun, S. H. [Daedeok College, Taejon (Korea, Republic of)

    2001-03-15

    In this development, we designed a integrated database for efficient data processing of radiation-environment data and developed the CLEAN (Computerized Local and overall country's Environmental data Analysis Network) system. The CLEAN system consists of local radiation-environment network, data analysis system, data open system. We developed the CLEAN system focused on building an integrated database, a data mart, and a CLEAN web site. It is expected that the developed system, which organizes the information related to environmental radiation data systematically, can be utilize for the accurate interpretation, analysis and evaluation.

  2. Interoperable computerized smart card based system for health insurance and health services applied in cardiology.

    Science.gov (United States)

    Cocei, Horia-Delatebea; Stefan, Livia; Dobre, Ioana; Croitoriu, Mihai; Sinescu, Crina; Ovricenco, Eduard

    2002-01-01

    In 1999 Romania started its health care reform by promulgating the Health Insurance Law. A functional and efficient health care system needs procedures for monitoring and evaluation of the medical services, communication between different service providers and entities involved in the system, integration and availability of the information. The final goal is a good response to the needs and demands of the patients and of the real life. For this project we took into account, on one hand, the immediate need for computerized systems for the health care providers and, on the other hand, the large number of trials and experiments with health smart cards across Europe. Our project will implement a management system based on electronic patient records to be used in all cardiology clinics and will experiment the health smart cards, will promote and demonstrate the capabilities of the smart card technology. We focused our attention towards a specific and also critical category of patients, those with heart diseases, and also towards a critical sector of the health care system--the emergency care. The patient card was tested on a number of 150 patients at a cardiology clinic in Bucharest. This was the first trial of a health smart card in Romania.

  3. Human Factors and Technical Considerations for a Computerized Operator Support System Prototype

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Thomas Anthony [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lew, Roger Thomas [Idaho National Lab. (INL), Idaho Falls, ID (United States); Medema, Heather Dawne [Idaho National Lab. (INL), Idaho Falls, ID (United States); Boring, Ronald Laurids [Idaho National Lab. (INL), Idaho Falls, ID (United States); Thomas, Kenneth David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    A prototype computerized operator support system (COSS) has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment. A COSS demonstration scenario has been developed for the prototype involving the Chemical & Volume Control System (CVCS) of the PWR simulator. It involves a primary coolant leak outside of containment that would require tripping the reactor if not mitigated in a very short timeframe. The COSS prototype presents a series of operator screens that provide the needed information and soft controls to successfully mitigate the event.

  4. Pain Perception: Computerized versus Traditional Local Anesthesia in Pediatric Patients.

    Science.gov (United States)

    Mittal, M; Kumar, A; Srivastava, D; Sharma, P; Sharma, S

    2015-01-01

    Local anesthetic injection is one of the most anxiety- provoking procedure for both children and adult patients in dentistry. A computerized system for slow delivery of local anesthetic has been developed as a possible solution to reduce the pain related to the local anesthetic injection. The present study was conducted to evaluate and compare pain perception rates in pediatric patients with computerized system and traditional methods, both objectively and subjectively. It was a randomized controlled study in one hundred children aged 8-12 years in healthy physical and mental state, assessed as being cooperative, requiring extraction of maxillary primary molars. Children were divided into two groups by random sampling - Group A received buccal and palatal infiltration injection using Wand, while Group B received buccal and palatal infiltration using traditional syringe. Visual Analog scale (VAS) was used for subjective evaluation of pain perception by patient. Sound, Eye, Motor (SEM) scale was used as an objective method where sound, eye and motor reactions of patient were observed and heart rate measurement using pulse oximeter was used as the physiological parameter for objective evaluation. Patients experienced significantly less pain of injection with the computerized method during palatal infiltration, while less pain was not statistically significant during buccal infiltration. Heart rate increased during both buccal and palatal infiltration in traditional and computerized local anesthesia, but difference between traditional and computerized method was not statistically significant. It was concluded that pain perception was significantly more during traditional palatal infiltration injection as compared to computerized palatal infiltration, while there was no difference in pain perception during buccal infiltration in both the groups.

  5. Correlations between the scores of computerized adaptive testing, paper and pencil tests, and the Korean Medical Licensing Examination

    Directory of Open Access Journals (Sweden)

    Mee Young Kim

    2005-06-01

    Full Text Available To evaluate the usefulness of computerized adaptive testing (CAT in medical school, the General Examination for senior medical students was administered as a paper and pencil test (P&P and using CAT. The General Examination is a graduate examination, which is also a preliminary examination for the Korean Medical Licensing Examination (KMLE. The correlations between the results of the CAT and P&P and KMLE were analyzed. The correlation between the CAT and P&P was 0.8013 (p=0.000; that between the CAT and P&P was 0.7861 (p=0.000; and that between the CAT and KMLE was 0.6436 (p=0.000. Six out of 12 students with an ability estimate below 0.52 failed the KMLE. The results showed that CAT could replace P&P in medical school. The ability of CAT to predict whether students would pass the KMLE was 0.5 when the criterion of the theta value was set at -0.52 that was chosen arbitrarily for the prediction of pass or failure.

  6. Computerizing Maintenance Management Improves School Processes.

    Science.gov (United States)

    Conroy, Pat

    2002-01-01

    Describes how a Computerized Maintenance Management System (CMMS), a centralized maintenance operations database that facilitates work order procedures and staff directives, can help individual school campuses and school districts to manage maintenance. Presents the benefits of CMMS and things to consider in CMMS selection. (EV)

  7. Quality criteria in computerized tomography of the chest

    International Nuclear Information System (INIS)

    Doehring, W.

    1985-01-01

    The quality of thoracical computerized tomography (CT) - like any other CT examination - depends from the quality of the equipment used, from the skill of the examinor and the properties of the patient. Concerning computerized chest tomograms, rapid scan equipment should be used only and slow translation - rotation systems should not be used any more. Whereas the quality of computerized tomograms may be influenced by the patient in the scanning process only, the examining physician will decisively influence the possible informative value of the examination also in the reconstruction of the CT value matrix, in single demonstration of CT values and, possibly, in additional measurement value processing as well as in the interpretation of findings. Use of equipment should always consider the technical potential provided by the equipment to be oriented to the clinical issue, and the conditions preset by the patient. (orig.) [de

  8. Computerized operation manual (COM) of nuclear power plants

    International Nuclear Information System (INIS)

    Szegi, Z.

    1985-01-01

    This paper is to be presented at the International Seminar on Diagnoses of and Response to Abnormal Occurrences at Nuclear Power Plants organized by the International Atomic Energy Agency. The topic of presentation is the Computerized Operational Manual. This system supports the operator at disturbance situations by displaying quickly and unambiguously the operational instructions and the relevant information without mistakes. By the computerized manual the operator can determine the instruction-subsystem which reflects the real state of the power unit. From this point the system guides the operator on how to drive the unit to another determined state by providing the operational instructions at any time. A data bank is also included which contains information concerning rules restricting on maintenance and repair. The system will be realized at Paks NPP. (author)

  9. Computerized plant maintenance management

    International Nuclear Information System (INIS)

    Kozusko, A.M.

    1986-01-01

    The evolution of the computer has and continues to have a great impact on industry. We are in an adjustment cycle with the current computer evolution, and will need to adapt to make the changes for the coming decade. Hardware and software are continually being enhanced. Computers are becoming more powerful and will eventually provide an effective man-machine interface. This paper shares experiences encountered during implementations of computerized maintenance systems

  10. Computerizing primary schools in rural kenya

    DEFF Research Database (Denmark)

    Ogembo, J.G.; Ngugi, B.; Pelowski, Matthew John

    2012-01-01

    questions surrounding this endeavour. Specifically: 1.) what problems do rural schools actually want to solve with computerization; 2.) is computerization the most important priority for rural schools; 3.) are schools ready, in terms of infrastructure, for a computer in the classroom; or 4.) might...... and protective roofing -posing severe challenges to the outstanding conception of computerization. We consider these results and make recommendations for better adapting programs for computer introduction, and also suggest the use of new innovative devices, such as cell phones, which might already have overcome......This paper investigates the outstanding challenges facing primary schools' computerization in rural Kenya. Computerization of schools is often envisaged as a 'magic', or at least a particularly efficient, solution to many of the problems that developing countries face in improving primary school...

  11. A novel computerized surgeon-machine interface for robot-assisted laser phonomicrosurgery.

    Science.gov (United States)

    Mattos, Leonardo S; Deshpande, Nikhil; Barresi, Giacinto; Guastini, Luca; Peretti, Giorgio

    2014-08-01

    To introduce a novel computerized surgical system for improved usability, intuitiveness, accuracy, and controllability in robot-assisted laser phonomicrosurgery. Pilot technology assessment. The novel system was developed involving a newly designed motorized laser micromanipulator, a touch-screen display, and a graphics stylus. The system allows the control of a CO2 laser through interaction between the stylus and the live video of the surgical area. This empowers the stylus with the ability to have actual effect on the surgical site. Surgical enhancements afforded by this system were established through a pilot technology assessment using randomized trials comparing its performance with a state-of-the-art laser microsurgery system. Resident surgeons and medical students were chosen as subjects in performing sets of trajectory-following exercises. Image processing-based techniques were used for an objective performance assessment. A System Usability Scale-based questionnaire was used for the qualitative assessment. The computerized interface demonstrated superiority in usability, accuracy, and controllability over the state-of-the-art system. Significant ease of use and learning experienced by the subjects were demonstrated by the usability score assigned to the two compared interfaces: computerized interface = 83.96% versus state-of-the-art = 68.02%. The objective analysis showed a significant enhancement in accuracy and controllability: computerized interface = 90.02% versus state-of-the-art = 75.59%. The novel system significantly enhances the accuracy, usability, and controllability in laser phonomicrosurgery. The design provides an opportunity to improve the ergonomics and safety of current surgical setups. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  12. Development of an item bank for computerized adaptive test (CAT) measurement of pain

    DEFF Research Database (Denmark)

    Petersen, Morten Aa.; Aaronson, Neil K; Chie, Wei-Chu

    2016-01-01

    PURPOSE: Patient-reported outcomes should ideally be adapted to the individual patient while maintaining comparability of scores across patients. This is achievable using computerized adaptive testing (CAT). The aim here was to develop an item bank for CAT measurement of the pain domain as measured...... were obtained from 1103 cancer patients from five countries. Psychometric evaluations showed that 16 items could be retained in a unidimensional item bank. Evaluations indicated that use of the CAT measure may reduce sample size requirements with 15-25 % compared to using the QLQ-C30 pain scale....... CONCLUSIONS: We have established an item bank of 16 items suitable for CAT measurement of pain. While being backward compatible with the QLQ-C30, the new item bank will significantly improve measurement precision of pain. We recommend initiating CAT measurement by screening for pain using the two original QLQ...

  13. Neurosurgical operating computerized tomographic scanner system. The CT scanner in the operating theater

    Energy Technology Data Exchange (ETDEWEB)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi

    1988-12-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place.

  14. Computerized accident management support system: development for severe accident management

    International Nuclear Information System (INIS)

    Garcia, V.; Saiz, J.; Gomez, C.

    1998-01-01

    The activities involved in the international Halden Reactor Project (HRP), sponsored by the OECD, include the development of a Computerized Accident Management Support System (CAMS). The system was initially designed for its operation under normal conditions, operational transients and non severe accidents. Its purpose is to detect the plant status, analyzing the future evolution of the sequence (initially using the APROS simulation code) and the possible recovery and mitigation actions in case of an accident occurs. In order to widen the scope of CAMS to severe accident management issues, the integration of the MAAP code in the system has been proposed, as the contribution of the Spanish Electrical Sector to the project (with the coordination of DTN). To include this new capacity in CAMS is necessary to modify the system structure, including two new modules (Diagnosis and Adjustment). These modules are being developed currently for Pressurized Water Reactors and Boiling Water REactors, by the engineering of UNION FENOSA and IBERDROLA companies (respectively). This motion presents the characteristics of the new structure of the CAMS, as well as the general characteristics of the modules, developed by these companies in the framework of the Halden Reactor Project. (Author)

  15. Computerized materials protection, control, and accountability at the Institute of Physics and Power Engineering

    International Nuclear Information System (INIS)

    Efimenko, V.; Goryunov, V.; Ilyantsev, A.

    1998-01-01

    As part of a multifaceted approach to protecting its nuclear materials, The Institute of Physics and Power Engineering (IPPE) at Obninsk, Russia, has been computerizing its materials protection, control, and accountability capabilities. This is being accomplished in collaboration with the CoreMAS team at Los Alamos National Laboratory. Such international cooperation in applying advanced science and technology to managing and controlling nuclear materials will help reduce the threat of nuclear weapons proliferation by preventing acquisition of weapons-grade nuclear materials by unauthorized individuals, organizations, or states. One important characteristic of IPPE is that it encompasses several facilities that manage nuclear materials, and three of these facilities already operate their own independent (or independently developed) computerized accounting systems. This paper focuses on the importance of compatibility between the computerized accountability systems at the facilities, the ability of the individual systems to communicate with a single site-wide system, and the necessity of coordination between facilities in designing and developing computerized systems. The authors believe that the lessons learned at IPPE in coordinating these efforts have wide-ranging significance for other sites with multiple facilities

  16. Feasibility analysis of CNP 1000 computerized I and C system design objectives

    International Nuclear Information System (INIS)

    Zhang Mingguang; Xu Jijun; Zhang Qinshen

    2000-01-01

    The author states the design objectives of the computerized I and C (CIC) system and advanced main control room (AMCR), which could and should be achieved in CNP 1000, based on the national 1E computer production technology including software and hardware, and current instrumentation and control design technique of nuclear power plant. The feasibility analysis on the design objectives and the reasons or necessity to do the design research projects have been described. The objectives of design research on CIC and AMCR as well as the self-design proficiency after the design research have been given

  17. Geometrical efficiency in computerized tomography: generalized model

    International Nuclear Information System (INIS)

    Costa, P.R.; Robilotta, C.C.

    1992-01-01

    A simplified model for producing sensitivity and exposure profiles in computerized tomographic system was recently developed allowing the forecast of profiles behaviour in the rotation center of the system. The generalization of this model for some point of the image plane was described, and the geometrical efficiency could be evaluated. (C.G.C.)

  18. Examinations and patient management in radiologic diagnostics by means of a computerized data-processing communications system

    International Nuclear Information System (INIS)

    Klotz, E.; Remplik, V.; Opfer, M.; Wilde, E.

    1986-01-01

    Concept, realization and a two-year experience in routine use of a computerized data-processing communications system supporting the central radiology department in a 1.625-bed, municipal hospital are discussed. Via the hospital ward-linked terminal network, routine X-ray examination is so ordered, that individual medical case information is provided, which certifies qualified clinical and diagnostic procedure along with good patient preparation and transportation. Complete information and documentation are also ensured. It was shown, that good motivation among involved radiologists and their close working-association with other departments are mandatory from the start to maintain exact time schedules and satisfactory completion of ordered X-ray procedures. Subsequently, the assistance through computerized data-processing becomes an accepted help - so far as it is appropriately used - as time goes by in its routine use. (orig.) [de

  19. Computerized Clinical Decision Support: Contributions from 2015

    Science.gov (United States)

    Bouaud, J.

    2016-01-01

    Summary Objective To summarize recent research and select the best papers published in 2015 in the field of computerized clinical decision support for the Decision Support section of the IMIA yearbook. Method A literature review was performed by searching two bibliographic databases for papers related to clinical decision support systems (CDSSs) and computerized provider order entry (CPOE) systems. The aim was to identify a list of candidate best papers from the retrieved papers that were then peer-reviewed by external reviewers. A consensus meeting between the two section editors and the IMIA editorial team was finally conducted to conclude in the best paper selection. Results Among the 974 retrieved papers, the entire review process resulted in the selection of four best papers. One paper reports on a CDSS routinely applied in pediatrics for more than 10 years, relying on adaptations of the Arden Syntax. Another paper assessed the acceptability and feasibility of an important CPOE evaluation tool in hospitals outside the US where it was developed. The third paper is a systematic, qualitative review, concerning usability flaws of medication-related alerting functions, providing an important evidence-based, methodological contribution in the domain of CDSS design and development in general. Lastly, the fourth paper describes a study quantifying the effect of a complex, continuous-care, guideline-based CDSS on the correctness and completeness of clinicians’ decisions. Conclusions While there are notable examples of routinely used decision support systems, this 2015 review on CDSSs and CPOE systems still shows that, despite methodological contributions, theoretical frameworks, and prototype developments, these technologies are not yet widely spread (at least with their full functionalities) in routine clinical practice. Further research, testing, evaluation, and training are still needed for these tools to be adopted in clinical practice and, ultimately, illustrate

  20. Computerized flow monitors detect small kicks

    Energy Technology Data Exchange (ETDEWEB)

    McCann, D.; White, D. (Sedco Forex, Paris (FR))

    1992-02-24

    This paper reports on a smart alarm system installed on a number of offshore rigs and one land rig which can detect kicks more quickly than conventional systems. This rapid kick detection improves rig safety because the smaller the detected influx, the easier it is to control the well. The extensive computerized monitoring system helps drilling personnel detect fluid influxes and fluid losses before the changes in flow would normally be apparent.

  1. Advantages obtained in radiation protection when using computerized radiography tests - CR (digital) in processing plants

    International Nuclear Information System (INIS)

    Jose, Joao Carlos Videira; Milani, Hilton Sergio B.; Paes, Eliseu Almir de Oliveira; Boita, Mario de; Souza, Laercio de; Serra, Flavio Augusto dos Santos

    2002-01-01

    During the year 2000, the ARCtest initiated the development of the research for adapting the Computerized Radiography - CR, originally conceived for medical applications, for the Industry, trying initially to attend the requirements of the processing plants, concerning to the detection of deterioration mechanisms (evaluation of the piping integrity). Due to the obtained excellent results, the possibility of utilization the Computerized Radiography - CR in the radiographic inspection were studied during the shutdown of the Catalytic Cracking Unit of the PETROBRAS-REPLAN, specifically in the replacement of the CO boiler superheater, where a large number of the small diameter welded joints have been predicted

  2. How will computerization revolutionize managed care?

    Science.gov (United States)

    Trabin, T

    1994-01-01

    Computerization of behavioral health care information systems is revolutionizing how payors, managed care companies, and providers exchange information. In this article, an imaginary scenario is depicted of how patient data will be accessed and communicated to facilitate care management of behavioral health care services in the near future.

  3. A COMPUTERIZED DIAGNOSTIC COMPLEX FOR RELIABILITY TESTING OF ELECTRIC MACHINES

    Directory of Open Access Journals (Sweden)

    O.О. Somka

    2015-06-01

    Full Text Available Purpose. To develop a diagnostic complex meeting the criteria and requirements for carrying out accelerated reliability test and realizing the basic modes of electric machines operation and performance of the posed problems necessary in the process of such test. Methodology. To determine and forecast the indices of electric machines reliability in accordance with the statistic data of repair plants we have conditionally divided them into structural parts that are most likely to fail. We have preliminarily assessed the state of each of these parts, which includes revelation of faults and deviations of technical and geometric parameters. We have determined the analyzed electric machine controlled parameters used for assessment of quantitative characteristics of reliability of these parts and electric machines on the whole. Results. As a result of the research, we have substantiated the structure of a computerized complex for electric machines reliability test. It allows us to change thermal and vibration actions without violation of the physics of the processes of aging and wearing of the basic structural parts and elements material. The above mentioned makes it possible to considerably reduce time spent on carrying out electric machines reliability tests and improve trustworthiness of the data obtained as a result of their performance. Originality. A special feature of determination of the controlled parameters consists in removal of vibration components in the idle mode and after disconnection of the analyzed electric machine from the power supply with the aim of singling out the vibration electromagnetic component, fixing the degree of sparking and bend of the shaft by means of phototechnique and local determination of structural parts temperature provided by corresponding location of thermal sensors. Practical value. We have offered a scheme of location of thermal and vibration sensors, which allows improvement of parameters measuring accuracy

  4. Development and implementation of computerized operator support systems in nuclear installations

    International Nuclear Information System (INIS)

    1994-01-01

    This report has been prepared to address the development and implementation of computerized operator support systems (COSS) in nuclear installations. The requirements of operators in information management and job performance in a control room environment are discussed. These requirements, which must be agreed to by the operators, provide a focus for the developers of COSS for implementation in an operational environment. The design methodology presents good practice approaches derived from the experience gained and the lessons learned during actual development of the COSS. The team concept, pilot study and structured step by step phases of software development and implementation should help COSS developers to achieve the level of quality and reliability required. 8 figs, 1 tab

  5. Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, F.J.O. [Instituto de Engenharia Nuclear, Cidade Universitaria, Rio de Janeiro, CEP 21945-970, Caixa Postal 68550 (Brazil)], E-mail: fferreira@ien.gov.br; Crispim, V.R.; Silva, A.X. [DNC/Poli, PEN COPPE CT, UFRJ Universidade Federal do Rio de Janeiro, CEP 21941-972, Caixa Postal 68509, Rio de Janeiro (Brazil)

    2010-06-15

    In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

  6. Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques

    International Nuclear Information System (INIS)

    Ferreira, F.J.O.; Crispim, V.R.; Silva, A.X.

    2010-01-01

    In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

  7. Risk-based management system development for the Advanced Test Reactor

    International Nuclear Information System (INIS)

    Davis, M.L.; Eide, S.A.

    1990-01-01

    A Risk-Based Management System (RBMS) is being developed to facilitate the use of the Advanced Test Reactor (ATR) probabilistic risk assessment to support ATR operation. Most ATR RBMS questions can best be answered using the System Analysis and Risk Assessment System (SARA) developed at the Idaho National Engineering Laboratory. However, some applications may require employment of the other four codes used to develop and report the PRA. These four codes include the Integrated Reliability and Risk Analysis System (IRRAS), SETS, ETA-II, and the Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR). The ATR RBMS will evolve over three years, and will include the results of the Level 3 and external events analysis

  8. The Computerized Reference Department: Buying the Future.

    Science.gov (United States)

    Kriz, Harry M.; Kok, Victoria T.

    1985-01-01

    Basis for systematic computerization of academic research library's reference, collection development, and collection management functions emphasizes productivity enhancement for librarians and support staff. Use of microcomputer and university's mainframe computer to develop applications of database management systems, electronic spreadsheets,…

  9. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  10. Development of a Computerized In-Basket Exercise for the Classroom: A Sales Management Example

    Science.gov (United States)

    Pearson, Michael M.; Barnes, John W.; Onken, Marina H.

    2006-01-01

    This article follows the development of a sales management in-basket exercise for use in the classroom. The authors have computerized the exercise and added features to allow for additional and more quantitative input from the students. The exercise has evolved and been tested in numerous classroom situations. The computerized in-basket exercise…

  11. Computerized analysis of fetal heart rate variability signal during the stages of labor.

    Science.gov (United States)

    Annunziata, Maria Laura; Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Giuliano, Natascia; Mereghini, Flavia; Di Lieto, Andrea; Campanile, Marta

    2016-03-01

    To analyze computerized cardiotocographic (cCTG) parameters (baseline fetal heart rate, baseline FHR; short term variability, STV; approximate entropy, ApEn; low frequency, LF; movement frequency, MF; high frequency, HF) in physiological pregnancy in order to correlate them with the stages of labor. This could provide more information for understanding the mechanisms of nervous system control of FHR during labor progression. A total of 534 pregnant women were monitored on cCTG from the 37th week before the onset of spontaneous labor and during the first and the second stage of labor. Statistical analysis was performed using Kruskal-Wallis test and Wilcoxon rank-sum test with the Bonferroni adjusted α (labor, and the first and second stages of labor. Differences between some of the stages were found for ApEn, LF and for LF/(HF + MF), where the first and the third were reduced and the second was increased. cCTG modifications during labor may reflect the physiologic increased activation of the autonomous nervous system. Using computerized fetal heart rate analysis during labor it may be possible to obtain more information from the fetal cardiac signal, in comparison with the traditional tracing. © 2016 Japan Society of Obstetrics and Gynecology.

  12. Normatização de um teste computadorizado de atenção visual: (TAVIS Normatization of a computerized visual attention test (TAVIS

    Directory of Open Access Journals (Sweden)

    Mônica Duchesne

    1997-01-01

    Full Text Available Os autores apresentam os dados normativos de um teste computadorizado de atenção visual (TAVIS para crianças e adolescentes, que representa o primeiro instrumento neuropsicológico deste tipo projetado e desenvolvido no Brasil. Três tarefas diferentes avaliam os apectos de seletividade, alternância e sustentação da atenção. Erros de omissão e ação, bem como o tempo de reação, são avaliados. São comentadas as vantagens e limitações do teste.The authors present the normative data of a computerized test (TAVIS that address visual attention in children and adolescents being the first neuropsychological instrument as such devised and developed in Brazil. Selective, alternate and sustained attention aspects are evaluated through three different tasks. Omission and action errors as well as time reaction are evaluated. The advantages and limitations of the test are commented.

  13. Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: methods of a decision-maker-researcher partnership systematic review.

    Science.gov (United States)

    Haynes, R Brian; Wilczynski, Nancy L

    2010-02-05

    Computerized clinical decision support systems are information technology-based systems designed to improve clinical decision-making. As with any healthcare intervention with claims to improve process of care or patient outcomes, decision support systems should be rigorously evaluated before widespread dissemination into clinical practice. Engaging healthcare providers and managers in the review process may facilitate knowledge translation and uptake. The objective of this research was to form a partnership of healthcare providers, managers, and researchers to review randomized controlled trials assessing the effects of computerized decision support for six clinical application areas: primary preventive care, therapeutic drug monitoring and dosing, drug prescribing, chronic disease management, diagnostic test ordering and interpretation, and acute care management; and to identify study characteristics that predict benefit. The review was undertaken by the Health Information Research Unit, McMaster University, in partnership with Hamilton Health Sciences, the Hamilton, Niagara, Haldimand, and Brant Local Health Integration Network, and pertinent healthcare service teams. Following agreement on information needs and interests with decision-makers, our earlier systematic review was updated by searching Medline, EMBASE, EBM Review databases, and Inspec, and reviewing reference lists through 6 January 2010. Data extraction items were expanded according to input from decision-makers. Authors of primary studies were contacted to confirm data and to provide additional information. Eligible trials were organized according to clinical area of application. We included randomized controlled trials that evaluated the effect on practitioner performance or patient outcomes of patient care provided with a computerized clinical decision support system compared with patient care without such a system. Data will be summarized using descriptive summary measures, including proportions

  14. Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: Methods of a decision-maker-researcher partnership systematic review

    Directory of Open Access Journals (Sweden)

    Wilczynski Nancy L

    2010-02-01

    Full Text Available Abstract Background Computerized clinical decision support systems are information technology-based systems designed to improve clinical decision-making. As with any healthcare intervention with claims to improve process of care or patient outcomes, decision support systems should be rigorously evaluated before widespread dissemination into clinical practice. Engaging healthcare providers and managers in the review process may facilitate knowledge translation and uptake. The objective of this research was to form a partnership of healthcare providers, managers, and researchers to review randomized controlled trials assessing the effects of computerized decision support for six clinical application areas: primary preventive care, therapeutic drug monitoring and dosing, drug prescribing, chronic disease management, diagnostic test ordering and interpretation, and acute care management; and to identify study characteristics that predict benefit. Methods The review was undertaken by the Health Information Research Unit, McMaster University, in partnership with Hamilton Health Sciences, the Hamilton, Niagara, Haldimand, and Brant Local Health Integration Network, and pertinent healthcare service teams. Following agreement on information needs and interests with decision-makers, our earlier systematic review was updated by searching Medline, EMBASE, EBM Review databases, and Inspec, and reviewing reference lists through 6 January 2010. Data extraction items were expanded according to input from decision-makers. Authors of primary studies were contacted to confirm data and to provide additional information. Eligible trials were organized according to clinical area of application. We included randomized controlled trials that evaluated the effect on practitioner performance or patient outcomes of patient care provided with a computerized clinical decision support system compared with patient care without such a system. Results Data will be summarized

  15. Unintended Transformations of Clinical Relations with a Computerized Physician Order Entry System

    DEFF Research Database (Denmark)

    Wentzer, Helle; Böttger, Ulrich; Boye, Niels

    2007-01-01

    A socio-technical approach was used to study the qualitative effects of deploying a medication CPOE (Computerized Physician Order Entry System with no decision support) at two internal medical wards in a hospital in Denmark. Our results show spatial and temporal transformations of core acts...... and relations in medication work, i.e. of the intended use of the system inscribed in hardware and software, in the relations of care between doctors and patients, of collaboration between doctors and nurses, and prospectively of the patients’ trajectories when readmitted to hospital or another health care...... or ‘doing medication’. The paper argues for the project organization to support the local collaboration and renegotiation of time and place of enacting medication with CPOE, as well as set up feedback for maturation of the software for future clinical use....

  16. Computerization of the standard corsi block-tapping task affects its underlying cognitive concepts : A pilot study

    NARCIS (Netherlands)

    Claessen, Michiel H G; Van Der Ham, Ineke J M; Van Zandvoort, Martine J E

    2015-01-01

    The tablet computer initiates an important step toward computerized administration of neuropsychological tests. Because of its lack of standardization, the Corsi Block-Tapping Task could benefit from advantages inherent to computerization. This task, which requires reproduction of a sequence of

  17. Computerization of the Standard Corsi Block-Tapping Task Affects Its Underlying Cognitive Concepts : A Pilot Study

    NARCIS (Netherlands)

    Claessen, Michiel H G; Van Der Ham, Ineke J M; Van Zandvoort, Martine J E

    2014-01-01

    The tablet computer initiates an important step toward computerized administration of neuropsychological tests. Because of its lack of standardization, the Corsi Block-Tapping Task could benefit from advantages inherent to computerization. This task, which requires reproduction of a sequence of

  18. Development of a Computerized Adaptive Test of Children's Gross Motor Skills.

    Science.gov (United States)

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Wu, Hing-Man; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2018-03-01

    To (1) develop a computerized adaptive test for gross motor skills (GM-CAT) as a diagnostic test and an outcome measure, using the gross motor skills subscale of the Comprehensive Developmental Inventory for Infants and Toddlers (CDIIT-GM) as the candidate item bank; and (2) examine the psychometric properties and the efficiency of the GM-CAT. Retrospective study. A developmental center of a medical center. Children with and without developmental delay (N=1738). Not applicable. The CDIIT-GM contains 56 universal items on gross motor skills assessing children's antigravity control, locomotion, and body movement coordination. The item bank of the GM-CAT had 44 items that met the dichotomous Rasch model's assumptions. High Rasch person reliabilities were found for each estimated gross motor skill for the GM-CAT (Rasch person reliabilities =.940-.995, SE=.68-2.43). For children aged 6 to 71 months, the GM-CAT had good concurrent validity (r values =.97-.98), adequate to excellent diagnostic accuracy (area under receiver operating characteristics curve =.80-.98), and moderate to large responsiveness (effect size =.65-5.82). The averages of items administered for the GM-CAT were 7 to 11, depending on the age group. The results of this study support the use of the GM-CAT as a diagnostic and outcome measure to estimate children's gross motor skills in both research and clinical settings. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. Reducing drug–herb interaction risk with a computerized reminder system

    Science.gov (United States)

    Lin, Sheng-Shing; Tsai, Chiu-Lin; Tu, Ching-Yeh; Hsieh, Ching-Liang

    2015-01-01

    Background Traditional Chinese medicine (TCM) and Western medicine are both popular in Taiwan. Approximately 14.1% of Taiwanese residents use Western drugs and Chinese herbs concurrently; therefore, drug–herb interaction is critical to patient safety. This paper presents a new procedure for reducing the risk of drug interactions. Methods Hospital computer systems are modified to ensure that drug–herb interactions are automatically detected when a TCM practitioner is writing a prescription. A pop-up reminder appears, warning of interactions, and the practitioner may adjust doses, delete herbs, or leave the prescription unchanged. A pharmacist will receive interaction information through the system and provide health education to the patient. Results During the 2011–2013 study period, 256 patients received 891 herbal prescriptions with potential drug–herb interactions. Three of the 50 patients who concurrently used ginseng and antidiabetic drugs manifested hypoglycemia (fasting blood sugar level ≤70 mg/dL). Conclusion Drug–herb interactions can cause adverse reactions. A computerized reminder system can enable TCM practitioners to reduce the risk of drug–herb interactions. In addition, health education for patients is crucial in avoiding adverse reaction by the interactions. PMID:25733840

  20. Computerized index for teaching files

    International Nuclear Information System (INIS)

    Bramble, J.M.

    1989-01-01

    A computerized index can be used to retrieve cases from a teaching file that have radiographic findings similar to an unknown case. The probability that a user will review cases with a correct diagnosis was estimated with use of radiographic findings of arthritis in hand radiographs of 110 cases from a teaching file. The nearest-neighbor classification algorithm was used as a computer index to 110 cases of arthritis. Each case was treated as an unknown and inputted to the computer index. The accuracy of the computer index in retrieving cases with the same diagnosis (including rheumatoid arthritis, gout, psoriatic arthritis, inflammatory osteoarthritis, and pyrophosphate arthropathy) was measured. A Bayes classifier algorithm was also tested on the same database. Results are presented. The nearest-neighbor algorithm was 83%. By comparison, the estimated accuracy of the Bayes classifier algorithm was 78%. Conclusions: A computerized index to a teaching file based on the nearest-neighbor algorithm should allow the user to review cases with the correct diagnosis of an unknown case, by entering the findings of the unknown case

  1. Computerized adaptive and multistage testing with R using packages catR and mstR

    CERN Document Server

    Magis, David; von Davier, Alina A

    2017-01-01

    The goal of this guide and manual is to provide a practical and brief overview of the theory on computerized adaptive testing (CAT) and multistage testing (MST) and to illustrate the methodologies and applications using R open source language and several data examples.  Implementation relies on the R packages catR and mstR that have been already or are being developed by the first author (with the team) and that include some of the newest research algorithms on the topic. The book covers many topics along with the R-code: the basics of R, theoretical overview of CAT and MST, CAT designs, CAT assembly methodologies, CAT simulations, catR package, CAT applications, MST designs, IRT-based MST methodologies, tree-based MST methodologies, mstR package, and MST applications.  CAT has been used in many large-scale assessments over recent decades, and MST has become very popular in recent years.  R open source language also has become one of the most useful tools for applications in almost all fields, including b...

  2. Computerized dosimetric system for studying radiation fields of afterloading apparatus

    International Nuclear Information System (INIS)

    Andryushin, O.S.; Gorshkov, M.I.

    1988-01-01

    Works on designing a computerized dosimetric scanner (CODOS) for studying radiation fields of remote therapeutic apparatus, providing dosimetric data input from semiconductor transducers and ionization chambers directly into the computer memory were carried out. The basic problems were to provide reproducibility and accuracy of the initial dosimetric data, formation of the data bank on LUEhV-15M1 accelerator bremsstrahlung and electron radiation fields. An extra problem was to provide isodose curves for manual scheduling of radiotherapy. The 15 VUMS-28-025 complex based on Elektronika-60 computer was chosen as a host computer, photodiodes were used as a semiconductor detector, the 70108 rod chamber and VA-J-18 dosemeters were used as an ionization chamber. The results of studies with the CODOS system have been shown that it meets the dosimetric requirements for therapeutic apparatus

  3. A modified conjugate gradient method based on the Tikhonov system for computerized tomography (CT).

    Science.gov (United States)

    Wang, Qi; Wang, Huaxiang

    2011-04-01

    During the past few decades, computerized tomography (CT) was widely used for non-destructive testing (NDT) and non-destructive examination (NDE) in the industrial area because of its characteristics of non-invasiveness and visibility. Recently, CT technology has been applied to multi-phase flow measurement. Using the principle of radiation attenuation measurements along different directions through the investigated object with a special reconstruction algorithm, cross-sectional information of the scanned object can be worked out. It is a typical inverse problem and has always been a challenge for its nonlinearity and ill-conditions. The Tikhonov regulation method is widely used for similar ill-posed problems. However, the conventional Tikhonov method does not provide reconstructions with qualities good enough, the relative errors between the reconstructed images and the real distribution should be further reduced. In this paper, a modified conjugate gradient (CG) method is applied to a Tikhonov system (MCGT method) for reconstructing CT images. The computational load is dominated by the number of independent measurements m, and a preconditioner is imported to lower the condition number of the Tikhonov system. Both simulation and experiment results indicate that the proposed method can reduce the computational time and improve the quality of image reconstruction. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  4. Human Reliability Analysis For Computerized Procedures

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Gertman, David I.; Le Blanc, Katya

    2011-01-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  5. Intraosseous anesthesia with solution injection controlled by a computerized system versus conventional oral anesthesia: A preliminary study

    OpenAIRE

    Beneito-Brotons, Rut; Peñarrocha-Oltra, David; Ata-Ali, Javier; Peñarrocha, María

    2011-01-01

    Objective: To compare a computerized intraosseous anesthesia system with the conventional oral anesthesia techniques, and analyze the latency and duration of the anesthetic effect and patient preference. Design: A simple-blind prospective study was made between March 2007 and May 2008. Each patient was subjected to two anesthetic techniques: conventional and intraosseous using the Quicksleeper® system (DHT, Cholet, France). A split-mouth design was adopted in which each patient underwent trea...

  6. Aiming for a fully integrated computerized procedure system

    International Nuclear Information System (INIS)

    Marron, J. E.

    2006-01-01

    A fully integrated Computerized Procedure System must provide, at a minimum, a) Specification: access to design basis procedures, b) Monitoring: incorporation of real-time plant status, c) Advise: highlighting likely decision paths, and d) Reporting: logging conditions and actions taken. The CPS plays a critical role in overcoming the human factors that lead to accidents. At the same time it can be an essential tool in providing the information and automation to augment what humans do best, identify patterns and make associative leaps in the presence of ambiguous data. Timeliner and TaskGuide are examples of CPS that have evolved from projects in the aerospace industry. They illustrate certain common characteristics of a CPS, namely the knowledge base, user interface, and traceability features. The complexity and number of procedures for a current nuclear project has led to the development of two tools, the Power Generation Control System (PGCS) and the Online Procedure System (OLPS). Together, these systems address the knowledge-base and user interface aspects of a CPS and go a long way in addressing other areas. PGCS and OLPS contain full configuration management capabilities for procedures and the operating recipe. They include administrative functions for online and offline management of documents and data. Some lessons learned from this pair of programs developed by Invensys is the need for more integrated recording mechanisms. The future of CPS is likely to see higher integration of the document access, system status, decision support and logging capabilities. The CPS may evolve into the standard operational interface. Internet technologies that are common-place today have made the possibility of the Active Document a reality. The OPC Foundation is pursuing standards that may accelerate such developments. (authors)

  7. Abnormal computerized dynamic posturography findings in dizzy patients with normal ENG results.

    Science.gov (United States)

    Sataloff, Robert T; Hawkshaw, Mary J; Mandel, Heidi; Zwislewski, Amy B; Armour, Jonathan; Mandel, Steven

    2005-04-01

    The complexities of the balance system create difficulties for professionals interested in testing equilibrium function objectively. Traditionally, electronystagmography (ENG) has been used for this purpose, but it provides information on only a limited portion of the equilibrium system. Computerized dynamic posturography (CDP) is less specific than ENG, but it provides more global insight into a patient's ability to maintain equilibrium under more challenging environmental circumstances. CD Palso appears to be valuable in obtaining objective confirmation of an abnormality in some dizzy patients whose ENG findings are normal. Our review of 33 patients with normal ENG results and abnormal CDP findings suggests that posturography is useful for confirming or quantifying a balance abnormality in some patients whose complaints cannot be confirmed by other tests frequently used by otologists.

  8. On the article of V. A. Mashin 'Computerized systems of NPP operators support. (Psychological problems)'

    International Nuclear Information System (INIS)

    Prushinskij, B.Ya.

    1995-01-01

    Basic aspects of V.A. Mashin's article on NPP operator support computerized systems and problems of man-machine interrelation are analyzed. Sharing in the significant degree Mashin's point of view the author of this article considers that the most important aspects of this problem consist in dividing the responsibility for NPP safe operation between all participants of the NPP creation and operation and in the area of practical experience in assuring control functions reliability

  9. Computerization of the nuclear material accounting system for safeguards purposes at nuclear power plants with WWER-440 reactors

    International Nuclear Information System (INIS)

    Antonov, V.P.; Konnov, Yu.I.; Semenets, A.N.

    1983-01-01

    The paper sets forth the basic principles underlying nuclear material accounting at nuclear power plants with WWER-440 reactors. It briefly describes the general structure and individual units in a program for computerized accounting. The use of this program is illustrated by the actual accounting data from the fifth unit of the Novovoronezh nuclear power station. The NUMIS program seems to be of interest both for the purposes of IAEA safeguards and for nuclear power plant operators in countries where power plants with WWER-440 reactors subject to IAEA safeguards are either in operation or under construction. The research in question was conducted initially under an IAEA research contract; the system is now being developed further and tested under the IAEA-USSR technical and scientific co-operation programme on safeguards. (author)

  10. Computerized method and system for designing an aerodynamic focusing lens stack

    Science.gov (United States)

    Gard, Eric [San Francisco, CA; Riot, Vincent [Oakland, CA; Coffee, Keith [Diablo Grande, CA; Woods, Bruce [Livermore, CA; Tobias, Herbert [Kensington, CA; Birch, Jim [Albany, CA; Weisgraber, Todd [Brentwood, CA

    2011-11-22

    A computerized method and system for designing an aerodynamic focusing lens stack, using input from a designer related to, for example, particle size range to be considered, characteristics of the gas to be flowed through the system, the upstream temperature and pressure at the top of a first focusing lens, the flow rate through the aerodynamic focusing lens stack equivalent at atmosphere pressure; and a Stokes number range. Based on the design parameters, the method and system determines the total number of focusing lenses and their respective orifice diameters required to focus the particle size range to be considered, by first calculating for the orifice diameter of the first focusing lens in the Stokes formula, and then using that value to determine, in iterative fashion, intermediate flow values which are themselves used to determine the orifice diameters of each succeeding focusing lens in the stack design, with the results being output to a designer. In addition, the Reynolds numbers associated with each focusing lens as well as exit nozzle size may also be determined to enhance the stack design.

  11. Safety implications of computerized process control in nuclear power plants

    International Nuclear Information System (INIS)

    1991-02-01

    Modern nuclear power plants are making increasing use of computerized process control because of the number of potential benefits that accrue. This practice not only applies to new plants but also to those in operation. Here, the replacement of both conventional process control systems and outdated computerized systems is seen to be of benefit. Whilst this contribution is obviously of great importance to the viability of nuclear electricity generation, it must be recognized that there are major safety concerns in taking this route. However, there is the potential for enhancing the safety of nuclear power plants if the full power of microcomputers and the associated electronics is applied correctly through well designed, engineered, installed and maintained systems. It is essential that areas where safety can be improved be identified and that the pitfalls are clearly marked so that they can be avoided. The deliberations of this Technical Committee Meeting are a step on the road to this goal of improved safety through computerized process control. This report also contains the papers presented at the technical committee meeting by participants. A separate abstract was prepared for each of these 15 presentations. Refs, figs and tabs

  12. A computerized system to monitor resilience indicators in organizations.

    Science.gov (United States)

    de Carvalho, Paulo Victor Rodrigues; de Souza, Alan Pinheiro; Gomes, Jose Orlando

    2012-01-01

    The concepts developed by resilience engineering allow the understanding and monitoring the functioning of organizations and, particularly, to map the role of human activities, in success or in failure, enabling a better comprehension about how people make decisions in unexpected situations. The capture of information about human activities in the various organization levels gives managers a deeper real-time understanding of what is influencing the people performance, providing awareness of the factors that influence positively or negatively the organizational goals initially projected. The monitoring is important because the correct functioning of complex systems depends on the knowledge that people have to perform their activities and how the system environment provides tools that actually support the human performance. Therefore, organizations should look forward through precursors in operating signals to identify possible problems or solutions in the structure of tasks and activities, safety, quality, schedule, rework, and maintenance. We apply the concepts of resilience engineering to understand the organization by the analysis of cognitive tasks and activities. The aim is the development of a computerized system to monitor human activities to produce indicators to access system resilience. The validation of the approach was made in a real organization and the results show the successful applicability of the system. Based on findings obtained after the experiment of the system in a real organization, and managers and workers opinions, it was possible to show that the use of system provided an anticipated (real-time) perception about how activities are effectively being performed, allowing managers and workers to make decisions more consistent with daily problems, and also to anticipate solutions to cope with unexpected situations.

  13. An accurate and efficient identification of children with psychosocial problems by means of computerized adaptive testing

    Directory of Open Access Journals (Sweden)

    Reijneveld Symen A

    2011-08-01

    Full Text Available Abstract Background Questionnaires used by health services to identify children with psychosocial problems are often rather short. The psychometric properties of such short questionnaires are mostly less than needed for an accurate distinction between children with and without problems. We aimed to assess whether a short Computerized Adaptive Test (CAT can overcome the weaknesses of short written questionnaires when identifying children with psychosocial problems. Method We used a Dutch national data set obtained from parents of children invited for a routine health examination by Preventive Child Healthcare with 205 items on behavioral and emotional problems (n = 2,041, response 84%. In a random subsample we determined which items met the requirements of an Item Response Theory (IRT model to a sufficient degree. Using those items, item parameters necessary for a CAT were calculated and a cut-off point was defined. In the remaining subsample we determined the validity and efficiency of a Computerized Adaptive Test using simulation techniques, with current treatment status and a clinical score on the Total Problem Scale (TPS of the Child Behavior Checklist as criteria. Results Out of 205 items available 190 sufficiently met the criteria of the underlying IRT model. For 90% of the children a score above or below cut-off point could be determined with 95% accuracy. The mean number of items needed to achieve this was 12. Sensitivity and specificity with the TPS as a criterion were 0.89 and 0.91, respectively. Conclusion An IRT-based CAT is a very promising option for the identification of psychosocial problems in children, as it can lead to an efficient, yet high-quality identification. The results of our simulation study need to be replicated in a real-life administration of this CAT.

  14. Use of computerized tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tjoerstad, K.

    1992-01-01

    This is a neurologist's opinion on how computerized tomography and magnetic resonance imaging have improved the doctor's diagnostic possibilities, changed patient/doctor relationship and increased the patients' expectations from diagnostic tests. How should the often conflicting interests of patients, society and doctors be handled? 15 refs., 1 fig., 1 tab

  15. Laboratory Computerization: The Case for a Prospective Analysis

    OpenAIRE

    Hurdle, John F.; Schwamm, Harry A.

    1982-01-01

    The argument is made that computerization of a laboratory should be preceeded by a thorough prospective analysis of laboratory operations. Points to be pondered include complementation of retrospective data, system cost justification, system performance justification, post-installation personnel adjustments, improved system utilization, improved manual performance, and insight into “how much” system to buy. A brief, general outline is offered describing how to approach such a study.

  16. Algorithms for Computerized Fetal Heart Rate Diagnosis with Direct Reporting

    Directory of Open Access Journals (Sweden)

    Kazuo Maeda

    2015-06-01

    Full Text Available Aims: Since pattern classification of fetal heart rate (FHR was subjective and enlarged interobserver difference, objective FHR analysis was achieved with computerized FHR diagnosis. Methods: The computer algorithm was composed of an experts’ knowledge system, including FHR analysis and FHR score calculation, and also of an objective artificial neural network system with software. In addition, a FHR frequency spectrum was studied to detect ominous sinusoidal FHR and the loss of baseline variability related to fetal brain damage. The algorithms were installed in a central-computerized automatic FHR monitoring system, which gave the diagnosis rapidly and directly to the attending doctor. Results: Clinically perinatal mortality decreased significantly and no cerebral palsy developed after introduction of the centralized system. Conclusion: The automatic multichannel FHR monitoring system improved the monitoring, increased the objectivity of FHR diagnosis and promoted clinical results.

  17. Physicians' Perceptions on the usefulness of contextual information for prioritizing and presenting alerts in computerized physician order entry systems

    NARCIS (Netherlands)

    Jung, Martin; Riedmann, Daniel; Hackl, Werner O.; Hoerbst, Alexander; Jaspers, Monique W.; Ferret, Laurie; Lawton, Kitta; Ammenwerth, Elske

    2012-01-01

    Background: One possible approach towards avoiding alert overload and alert fatigue in Computerized Physician Order Entry (CPOE) systems is to tailor their drug safety alerts to the context of the clinical situation. Our objective was to identify the perceptions of physicians on the usefulness of

  18. Seize the data (Carpe data) : wave of computerized data capture technology sweeps drilling industry

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, J.

    1999-02-01

    The computerization of all aspects of the monitoring and collection of well drilling information is discussed. Global Link International Inc. of Calgary, has developed a computerized system for tracking and recording drilling data. This operations recording database is named the Electronic Tour Book (ETB). It is similar to the Electronic Tour Sheet (ETS) developed by Chimo Equipment Ltd. of Alberta. Both Windows-based systems represent computerized reporting mechanisms for operators, producers, loggers and rig-managers. Another Alberta company, Ryan Energy Technologies Inc., has begun marketing the Tru Vu Fusion system of hardware and software, yet another system for gathering and recording drilling data. Tru Vu Fusion can capture data and display it in a format that everybody at the wellsite can use for decision making. Another drilling data management system, entitled INSITE (for Integrated System for Information Technology and Engineering) is marketed by Sperry-Sun Drilling Services. While INSITE is intended primarily for offshore drilling applications, it can be used onshore with equal success. 4 figs.

  19. Development of a computerized handbook of architectural plans

    NARCIS (Netherlands)

    Koutamanis, A.

    1990-01-01

    The dissertation investigates an approach to the development of visual / spatial computer representations for architectural purposes through the development of the computerized handbook of architectural plans (chap), a knowledge-based computer system capable of recognizing the metric properties of

  20. Computerized coding system for life narratives to assess students' personality adaption

    NARCIS (Netherlands)

    He, Q.; Veldkamp, B.P.; Westerhof, G.J.; Pechenizkiy, Mykola; Calders, Toon; Conati, Cristina; Ventura, Sebastian; Romero, Cristobal; Stamper, John

    2011-01-01

    The present study is a trial in developing an automatic computerized coding framework with text mining techniques to identify the characteristics of redemption and contamination in life narratives written by undergraduate students. In the initial stage of text classification, the keyword-based

  1. Density evaluation by computerized tomography in plain soils over different manipulation systems; Avaliacao da densidade pelo metodo da tomografia computadorizada de um planossolo sob diferentes sistemas de manejo

    Energy Technology Data Exchange (ETDEWEB)

    Pedrotti, Alceu [Lavras Univ., MG (Brazil). Dept. de Ciencia do Solo; Pauletto, Eloy Antonio [Pelotas Univ., RS (Brazil). Dept. de Solos; Crestana, Silvio [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Sao Carlos, SP (Brazil). Centro Nacional de Pesquisa e Desenvolvimento de Instrumentacao Agropecuaria (CNPDIA)

    1996-08-01

    The objective of this paper is the evaluation of a plain soil density in different culture systems determined by X ray computerized tomography.It was observed a larger variation in densities in soils profiles analysed. The identification of layers is better utilising computerized tomography than others technic 1 fig.

  2. Statistical tests for person misfit in computerized adaptive testing

    NARCIS (Netherlands)

    Glas, Cornelis A.W.; Meijer, R.R.; van Krimpen-Stoop, Edith

    1998-01-01

    Recently, several person-fit statistics have been proposed to detect nonfitting response patterns. This study is designed to generalize an approach followed by Klauer (1995) to an adaptive testing system using the two-parameter logistic model (2PL) as a null model. The approach developed by Klauer

  3. Technologies in computerized lexicography | Kruyt | Lexikos

    African Journals Online (AJOL)

    Although the topic of this paper is technology, focus is on functional rather than technical aspects of computerized lexicography. Keywords: computerized lexicography, electronic dictionary, electronic text corpus, lexicographer's workbench, integrated language database, automatic linguistic analysis, information retrieval, ...

  4. Computerized Point of Sale = Faster Service + Better Accountability.

    Science.gov (United States)

    Pannell, Dorothy V.

    1991-01-01

    Describes selecting and installing a computerized point of sale for a district food service program; the equipment needed and preferred; and the training of trainers, managers, and cashiers. Also discusses the direct benefits and side benefits of the system. (MLF)

  5. Towards Computerized Adaptive Assessment Based on Structured Tasks

    NARCIS (Netherlands)

    Tvarožek, Jozef; Kravcik, Milos; Bieliková, Mária

    2008-01-01

    Tvarožek, J., Kravčík, M., & Bieliková, M. (2008). Towards Computerized Adaptive Assessment Based on Structured Tasks. In W. Nejdl et al. (Eds.), Adaptive Hypermedia and Adaptive Web-Based Systems (pp. 224-234). Springer Berlin / Heidelberg.

  6. A Multisite, Randomized Controlled Clinical Trial of Computerized Cognitive Remediation Therapy for Schizophrenia.

    Science.gov (United States)

    Gomar, Jesús J; Valls, Elia; Radua, Joaquim; Mareca, Celia; Tristany, Josep; del Olmo, Francisco; Rebolleda-Gil, Carlos; Jañez-Álvarez, María; de Álvaro, Francisco J; Ovejero, María R; Llorente, Ana; Teixidó, Cristina; Donaire, Ana M; García-Laredo, Eduardo; Lazcanoiturburu, Andrea; Granell, Luis; Mozo, Cristina de Pablo; Pérez-Hernández, Mónica; Moreno-Alcázar, Ana; Pomarol-Clotet, Edith; McKenna, Peter J

    2015-11-01

    The effectiveness of cognitive remediation therapy (CRT) for the neuropsychological deficits seen in schizophrenia is supported by meta-analysis. However, a recent methodologically rigorous trial had negative findings. In this study, 130 chronic schizophrenic patients were randomly assigned to computerized CRT, an active computerized control condition (CC) or treatment as usual (TAU). Primary outcome measures were 2 ecologically valid batteries of executive function and memory, rated under blind conditions; other executive and memory tests and a measure of overall cognitive function were also employed. Carer ratings of executive and memory failures in daily life were obtained before and after treatment. Computerized CRT was found to produce improvement on the training tasks, but this did not transfer to gains on the primary outcome measures and most other neuropsychological tests in comparison to either CC or TAU conditions. Nor did the intervention result in benefits on carer ratings of daily life cognitive failures. According to this study, computerized CRT is not effective in schizophrenia. The use of both active and passive CCs suggests that nature of the control group is not an important factor influencing results. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center.

  7. Computerized Analytical Data Management System and Automated Analytical Sample Transfer System at the COGEMA Reprocessing Plants in La Hague

    International Nuclear Information System (INIS)

    Flament, T.; Goasmat, F.; Poilane, F.

    2002-01-01

    Managing the operation of large commercial spent nuclear fuel reprocessing plants, such as UP3 and UP2-800 in La Hague, France, requires an extensive analytical program and the shortest possible analysis response times. COGEMA, together with its engineering subsidiary SGN, decided to build high-performance laboratories to support operations in its plants. These laboratories feature automated equipment, safe environments for operators, and short response times, all in centralized installations. Implementation of a computerized analytical data management system and a fully automated pneumatic system for the transfer of radioactive samples was a key factor contributing to the successful operation of the laboratories and plants

  8. [Computerized medical record: deontology and legislation].

    Science.gov (United States)

    Allaert, F A; Dusserre, L

    1996-02-01

    Computerization of medical records is making headway for patients' follow-up, scientific research, and health expenses control, but it must not alter the guarantees provided to the patients by the medical code of ethics and the law of January 6, 1978. This law, modified on July 1, 1994, requires to register all computerized records of personal data and establishes rights to protect privacy against computer misdemeanor. All medical practitioners using computerized medical records must be aware that the infringement of this law may provoke suing in professional, civil or criminal court.

  9. Computerized system of team make-up and work allocation in the Belgian Zolder mine

    Energy Technology Data Exchange (ETDEWEB)

    Rustanowicz, M.

    1979-01-01

    System of work allocation introduced in 1974 in the Zolder Coal Mine (NV Kempense Steenkolenmijnen) in Belgium is evaluated. The system is based on an IBM 370/158 computer. An information management system supervises the programing work. There are approximately 30 programs. Absenteeism in the Belgian coal mines is generally high at approximately 24% and some months as high as 40%. Therefore, introducing a computerized system of work allocation and team make-up was advantageous. Operation of the system is described on the levels of foreman, engineers and director of the mine. Advantages of the system are numerous. It enables optimization of team make-up and work allocation, shortens the time of allocation of work by a foreman, increases efficiency of foremen's work and provides the director with the means and information necessary for efficient decision making in improving the productivity of the mine. (5 refs.) (In Polish)

  10. Assessing a computerized routine health information system in Mali using LQAS.

    Science.gov (United States)

    Stewart, J C; Schroeder, D G; Marsh, D R; Allhasane, S; Kone, D

    2001-09-01

    Between 1987 and 1998 Save the Children conducted a child survival programme in Mali with the goal of reducing maternal and child morbidity and mortality. An integral part of this programme was a computerized demographic surveillance and health information system (HIS) that gathered data on individuals on an on-going basis. To assess the overall coverage and quality of the data in the HIS, to identify specific health districts that needed improvements in data collection methods, and to determine particular areas of weakness in data collection. Random samples of 20 mothers with children LQAS) was used to identify districts in which records and interview results did not meet predetermined levels of acceptability. Data collected in the interviews were combined to estimate overall coverage and quality. When all variables were analyzed, all 14 lots were rejected, and it was estimated that 52% of all events occurring in the community were registered in ProMIS. Much of this poor performance was due to immunization and growth monitoring data, which were not updated due to printer problems. Coverage of events increased (92%) when immunizations and growth monitoring were excluded, and no lots were rejected. When all variables were analyzed for quality of data recorded, six lots were rejected and the overall estimation was 83%. With immunizations and growth monitoring excluded, overall quality was 86% and no lots were rejected. The comprehensive computerized HIS did not meet expectations. This may be due, in part, to the ambitious objective of complete and intensive monitoring of a large population without adequate staff and equipment. Future efforts should consider employing a more targeted and streamlined HIS so that data can be more complete and useful.

  11. Computerized Decision Aids for Shared Decision Making in Serious Illness: Systematic Review.

    Science.gov (United States)

    Staszewska, Anna; Zaki, Pearl; Lee, Joon

    2017-10-06

    Shared decision making (SDM) is important in achieving patient-centered care. SDM tools such as decision aids are intended to inform the patient. When used to assist in decision making between treatments, decision aids have been shown to reduce decisional conflict, increase ease of decision making, and increase modification of previous decisions. The purpose of this systematic review is to assess the impact of computerized decision aids on patient-centered outcomes related to SDM for seriously ill patients. PubMed and Scopus databases were searched to identify randomized controlled trials (RCTs) that assessed the impact of computerized decision aids on patient-centered outcomes and SDM in serious illness. Six RCTs were identified and data were extracted on study population, design, and results. Risk of bias was assessed by a modified Cochrane Risk of Bias Tool for Quality Assessment of Randomized Controlled Trials. Six RCTs tested decision tools in varying serious illnesses. Three studies compared different computerized decision aids against each other and a control. All but one study demonstrated improvement in at least one patient-centered outcome. Computerized decision tools may reduce unnecessary treatment in patients with low disease severity in comparison with informational pamphlets. Additionally, electronic health record (EHR) portals may provide the opportunity to manage care from the home for individuals affected by illness. The quality of decision aids is of great importance. Furthermore, satisfaction with the use of tools is associated with increased patient satisfaction and reduced decisional conflict. Finally, patients may benefit from computerized decision tools without the need for increased physician involvement. Most computerized decision aids improved at least one patient-centered outcome. All RCTs identified were at a High Risk of Bias or Unclear Risk of Bias. Effort should be made to improve the quality of RCTs testing SDM aids in serious

  12. Commissioning and quality assurance of computerized planning systems for radiation treatment of cancer

    International Nuclear Information System (INIS)

    2004-01-01

    Cancer is a significant health care problem; on average about half of all cancer patients are treated with radiation therapy worldwide. This mode of treatment uses complex technology that involves megavoltage radiation that, if not handled with the greatest of care, could lead to significant patient treatment errors and exposures of staff. Recent years have seen a rapid development in the technology of radiation oncology. One of the prime factors contributing to this rapid development has been the evolution of computer technology and its applications in: (a) patient diagnosis using sophisticated computerized diagnostic imaging equipment; (b) the process of radiation treatment planning using computerized radiation treatment planning systems (TPSs) that are capable of using data from diagnostic imagers; and (c) radiation dose delivery using relatively simple 60 Co machines or complex linear accelerators with computer controlled delivery systems including multileaf collimators (MLCs) for field shaping, possibly in a dynamic mode while the beam is on. The radiation treatment process involves the application of some or all of these technologies to provide the desired dose to the target volume while minimizing exposure to adjacent normal tissues. While dose computational equipment was available as early as 1951, more generalized treatment planning calculations evolved, including under the sponsorship of the IAEA, in the 1960s that made use of time sharing systems to develop atlases of isodose distributions for general use. In the 1970s and 1980s treatment planning computers became more specialized and readily available to individual radiation therapy centres. As computer technology evolved and became more compact so did TPSs, while at the same time dose calculation algorithms and image display capabilities became more sophisticated. While there is a substantial variation in capabilities, today's treatment planning computers have become readily available to virtually all

  13. An ergonomics study of computerized emergency operating procedures: Presentation style, task complexity, and training level

    International Nuclear Information System (INIS)

    Xu Song; Song Fei; Li Zhizhong; Zhao Qianyi; Luo Wei; He Xuhong; Salvendy, Gavriel

    2008-01-01

    Emergency operating procedures (EOPs) are widely used in nuclear power plants (NPPs). With the development of information technology, computerized EOPs are taking the place of paper-based ones. Unlike paper-based EOPs, the industrial practice of computerized EOPs is still quite limited. Ergonomics issues of computerized EOPs have not been studied adequately. This study focuses on the effects of EOP presentation style, task complexity, and training level on the performance of the operators in the execution of computerized EOPs. One simulated computerized EOP system was developed to present two EOPs, each with different task complexity levels, by two presentation styles (Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination). Forty subjects participated in the experiment of EOP execution using the simulated system. Statistical analysis of the experimental results indicates that: (1) complexity, presentation style, and training level all can significantly influence the error rate. High-complexity tasks and lack of sufficient training may lead to a higher error rate. Style B caused a significantly higher error rate than style A did in the skilled phase. So the designers of computerized procedures should take the presentation styles of EOPs into account. (2) Task complexity and training level can significantly influence operation time. No significant difference was found in operation time between the two presentation styles. (3) Training level can also significantly influence the subjective workload of EOPs operations. This implies that adequate training is very important for the performance of computerized EOPs even if emergency responses with computerized EOPs are much more simple and easy than that with paper-based EOPs

  14. An ergonomics study of computerized emergency operating procedures: Presentation style, task complexity, and training level

    Energy Technology Data Exchange (ETDEWEB)

    Xu Song; Song Fei [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Li Zhizhong [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)], E-mail: zzli@tsinghua.edu.cn; Zhao Qianyi; Luo Wei [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); He Xuhong [Scanpower Risk Management China Inc., Towercrest International Plaza, No. 3 Maizidian West Road, Chaoyang District, Beijing 100016 (China); Salvendy, Gavriel [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)

    2008-10-15

    Emergency operating procedures (EOPs) are widely used in nuclear power plants (NPPs). With the development of information technology, computerized EOPs are taking the place of paper-based ones. Unlike paper-based EOPs, the industrial practice of computerized EOPs is still quite limited. Ergonomics issues of computerized EOPs have not been studied adequately. This study focuses on the effects of EOP presentation style, task complexity, and training level on the performance of the operators in the execution of computerized EOPs. One simulated computerized EOP system was developed to present two EOPs, each with different task complexity levels, by two presentation styles (Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination). Forty subjects participated in the experiment of EOP execution using the simulated system. Statistical analysis of the experimental results indicates that: (1) complexity, presentation style, and training level all can significantly influence the error rate. High-complexity tasks and lack of sufficient training may lead to a higher error rate. Style B caused a significantly higher error rate than style A did in the skilled phase. So the designers of computerized procedures should take the presentation styles of EOPs into account. (2) Task complexity and training level can significantly influence operation time. No significant difference was found in operation time between the two presentation styles. (3) Training level can also significantly influence the subjective workload of EOPs operations. This implies that adequate training is very important for the performance of computerized EOPs even if emergency responses with computerized EOPs are much more simple and easy than that with paper-based EOPs.

  15. Validation of the news computerizing renography system developed of the CEADEN in order to improve the renography system existing at the National Nephrology Institute

    International Nuclear Information System (INIS)

    Medina Martin, D.; Rodriguez Gonzalez, F.; Arista Romeu, E.; Diaz Barreto, M.; Fraxedas Mayor, R.

    1999-01-01

    The isotopic renography is a technique that permits the evaluation of renal and the urinary tract diseases. In our country is not possible performs these studies only using gamma cameras due to the high costs of this technique, so the renography results an important method for this. It was developed a computerizing renography system in order to improve the renography system existing at the National Nephrology Institute (INEF), which is the head institute in this field in Cuba. The computerizing renography system includes a detection system, an interface card and software. As detection system was using the existing at the Institute. Specialists of the CEADEN using the high experience of the INEF and the international standards developed the card and software. The new software has several advantages with respect to the ancient, as example: normalized and standardizing control and processing protocols, a higher number of studies, the conduction and parameters validation of the studies, help system included, a database with the study results, teaching possibilities, etc. The validation of the news card and software was carried out simultaneously with the old system during 1 year approximately. This permitted to compare the main parameters and results in both systems. The results obtained were analyzed using statistical programs. As conclusion we obtained that both systems have a high correlation, so it is possible to substitute the old system with a more powerful and integral renography system

  16. Value of computerized tomography in the diagnosis of bone and musculoskeletal system tumors of the pelvis and extremities

    International Nuclear Information System (INIS)

    Langer, R.; Langer, M.

    1983-01-01

    49 cases of tumors of the musculoskeletal system of the pelvis and the extremities have been investigated by computerized tomography. The CT was performed only after conventional radiologic methods. The results are discussed and compared with those described in the literature. The advantages and disadvantages of CT of musculoskeletal disorders are discussed. We consider the CT to be of value in disorders of the musculoskeletal system, specially, if operative- or radiotherapy is planned. (orig.) [de

  17. Safeguarding nuclear materials in the former Soviet Republics through computerized materials protection, control and accountability

    International Nuclear Information System (INIS)

    Roumiantsev, A.N.; Ostroumov, Y.A.; Whiteson, R.; Seitz, S.L.; Landry, R.P.; Martinez, B.J.; Boor, M.G.; Anderson, L.K.; Gary, S.P.

    1997-01-01

    The threat of nuclear weapons proliferation is a problem of global concern. International efforts at nonproliferation focus on preventing acquisition of weapons-grade nuclear materials by unauthorized states, organizations, or individuals. Nonproliferation can best be accomplished through international cooperation in the application of advanced science and technology to the management and control of nuclear materials. Computerized systems for nuclear material protection, control, and accountability (MPC and A) are a vital component of integrated nuclear safeguards programs. This paper describes the progress of scientists in the United States and former Soviet Republics in creating customized, computerized MPC and A systems. The authors discuss implementation of the Core Material Accountability System (CoreMAS), which was developed at Los Alamos National Laboratory by the US Department of Energy and incorporates, in condensed and integrated form, the most valuable experience gained by US nuclear enterprises in accounting for and controlling nuclear materials. The CoreMAS approach and corresponding software package have been made available to sites internationally. CoreMAS provides methods to evaluate their existing systems and to examine advantages and disadvantages of customizing CoreMAS or improving their own existing systems. The sites can also address crucial issues of software assurance, data security, and system performance; compare operational experiences at sites with functioning computerized systems; and reasonably evaluate future efforts. The goal of the CoreMAS project is to introduce facilities at sites all over the world to modern international MPC and A practices and to help them implement effective, modern, computerized MPC and A systems to account for their nuclear materials, and thus reduce the likelihood of theft or diversion. Sites are assisted with MPC and A concepts and the implementation of an effective computerized MPC and A system

  18. Computerised weld strength testing machine for PHWR fuel elements with a versatile control system

    International Nuclear Information System (INIS)

    Gupta, U.C.; Sastry, V.S.; Rasheed, Jawad; Bibawe, S.R.

    1994-01-01

    Spacer pads and bearing pads are resistance spot welded on PHWR fuel elements to ensure inter-element gap for coolant flow. These welds are subjected to destructive tests as per SQC specifications while qualifying a machine and during production. The testing machine used earlier over the years was tedious involving manual operations of clamping, tool actuation, increasing and decreasing the pressure, referring to charts and statistical calculations. To carry out the destructive testing of the welds conveniently and reliably, an automatic machine is developed in-house in which are incorporated a quartz force transducer and a computerized data-acquisition and processing system together with a very versatile electronic control system based on a single-chip microcomputer. This paper describes the salient features of the machine and the control system. (author). 4 figs

  19. Cost-effectiveness analysis of computerized ECG interpretation system in an ambulatory health care organization.

    Science.gov (United States)

    Carel, R S

    1982-04-01

    The cost-effectiveness of a computerized ECG interpretation system in an ambulatory health care organization has been evaluated in comparison with a conventional (manual) system. The automated system was shown to be more cost-effective at a minimum load of 2,500 patients/month. At larger monthly loads an even greater cost-effectiveness was found, the average cost/ECG being about $2. In the manual system the cost/unit is practically independent of patient load. This is primarily due to the fact that 87% of the cost/ECG is attributable to wages and fees of highly trained personnel. In the automated system, on the other hand, the cost/ECG is heavily dependent on examinee load. This is due to the relatively large impact of equipment depreciation on fixed (and total) cost. Utilization of a computer-assisted system leads to marked reduction in cardiologists' interpretation time, substantially shorter turnaround time (of unconfirmed reports), and potential provision of simultaneous service at several remotely located "heart stations."

  20. Morphological analysis of the vestibular aqueduct by computerized tomography images

    International Nuclear Information System (INIS)

    Marques, Sergio Ricardo; Smith, Ricardo Luiz; Isotani, Sadao; Alonso, Luis Garcia; Anadao, Carlos Augusto; Prates, Jose Carlos; Lederman, Henrique Manoel

    2007-01-01

    Objective: In the last two decades, advances in the computerized tomography (CT) field revise the internal and medium ear evaluation. Therefore, the aim of this study is to analyze the morphology and morphometric aspects of the vestibular aqueduct on the basis of computerized tomography images (CTI). Material and method: Computerized tomography images of vestibular aqueducts were acquired from patients (n = 110) with an age range of 1-92 years. Thereafter, from the vestibular aqueducts images a morphometric analysis was performed. Through a computerized image processing system, the vestibular aqueduct measurements comprised of its area, external opening, length and the distance from the vestibular aqueduct to the internal acoustic meatus. Results: The morphology of the vestibular aqueduct may be funnel-shaped, filiform or tubular and the respective proportions were found to be at 44%, 33% and 22% in children and 21.7%, 53.3% and 25% in adults. The morphometric data showed to be of 4.86 mm 2 of area, 2.24 mm of the external opening, 4.73 mm of length and 11.88 mm of the distance from the vestibular aqueduct to the internal acoustic meatus, in children, and in adults it was of 4.93 mm 2 , 2.09 mm, 4.44 mm, and 11.35 mm, respectively. Conclusions: Computerized tomography showed that the vestibular aqueduct presents high morphological variability. The morphometric analysis showed that the differences found between groups of children and adults or between groups of both genders were not statistically significant

  1. Sex differences in strategy and performance on computerized neuropsychological tests as related to gender identity and age at puberty.

    Science.gov (United States)

    Meurling, A W; Tonning-Olsson, I; Levander, S

    2000-06-01

    Neuropsychological sex differences have since long been under debate. Support for the relation between behavioral differences and biological variables like hormone influence is, however, emerging. Sixteen men and sixteen women, all university students, were tested with computerized neuropsychological tests (APT), the Bem Sexual Role Inventory, and asked about pubertal age. The results were in line with earlier findings of sex differences in neuropsychological tests, men being faster and women more cautious. The assumption that women tend to use left-hemispheric, verbal/serial strategies also in spatial tasks was also partly supported. In women, late onset of puberty was related to better spatial performance, and there were also more intercorrelations between verbal and spatial tests in the female than in the male group, indicating that women use less specific strategies (more g-factor intelligence) in problem solving, or that aptitudes are less compartmentalized in women than in men.

  2. Modification and upgradation of corrosion fatigue testing system

    International Nuclear Information System (INIS)

    Farooq, A.; Qamar, R.

    2006-08-01

    Stress Corrosion Cracking (SCC) and Corrosion Fatigue (CF) are important tests which are performed to check the integrity of structural materials operating in different environments, such as nuclear power system, steam and gas turbines, aircraft marine structure, pipelines and bridges. To establish the environmental testing facility on laboratory scale, NMD acquired a computerized (286 Based PC) electromechanical testing machine from M/S CorTest, USA. This machine was commissioned at NMD in 1989. Since then it has been utilized to test and qualify the materials provided by different establishments of PAEC for SCC and CF behavior. However, in October 2004, computer attached to the machine was corrupted and became out of order. Users were handicapped because there was no any alternate system i.e. Manual control tower to operate the machine. Then users approached to Computer Division to investigate the malfunctioning at the computer. Therefore, upon complete checkup of system, it was diagnosed that there was a serious problem in the hard disk and mother board of the computer. Much difficulty was faced in retrieving the application software from the obsolete 286 computer system. Then the basic aim was to replace the old computer with Pentium System. But with Pentium system application software was not working. Since we have already recovered full application software package including source programs, so all the seventeen programs has been thoroughly studied. Four programs had to be modified according to the new hardware. Now the new Pentium system with modified software has been interfaced with the machine. Machine was tested for the both types of above mentioned tests and compared with previous results. The performance of machine was confirmed satisfactory on the new setup. (author)

  3. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  4. Computerized Adaptive Tests Detect Change Following Orthopaedic Surgery in Youth with Cerebral Palsy.

    Science.gov (United States)

    Mulcahey, M J; Slavin, Mary D; Ni, Pengsheng; Vogel, Lawrence C; Kozin, Scott H; Haley, Stephen M; Jette, Alan M

    2015-09-16

    The Cerebral Palsy Computerized Adaptive Test (CP-CAT) is a parent-reported outcomes instrument for measuring lower and upper-extremity function, activity, and global health across impairment levels and a broad age range of children with cerebral palsy (CP). This study was performed to examine whether the Lower Extremity/Mobility (LE) CP-CAT detects change in mobility following orthopaedic surgery in children with CP. This multicenter, longitudinal study involved administration of the LE CP-CAT, the Pediatric Outcomes Data Collection Instrument (PODCI) Transfer/Mobility and Sports/Physical Functioning domains, and the Timed "Up & Go" test (TUG) before and after elective orthopaedic surgery in a convenience sample of 255 children, four to twenty years of age, who had CP and a Gross Motor Function Classification System (GMFCS) level of I, II, or III. Standardized response means (SRMs) and 95% confidence intervals (CIs) were calculated for all measures at six, twelve, and twenty-four months following surgery. SRM estimates for the LE CP-CAT were significantly greater than the SRM estimates for the PODCI Transfer/Mobility domain at twelve months, the PODCI Sports/Physical Functioning domain at twelve months, and the TUG at twelve and twenty-four months. When the results for the children at GMFCS levels I, II, and III were grouped together, the improvements in function detected by the LE CP-CAT at twelve and twenty-four months were found to be greater than the changes detected by the PODCI Transfer/Mobility and Sports/Physical Functioning scales. The LE CP-CAT outperformed the PODCI scales for GMFCS levels I and III at both of these follow-up intervals; none of the scales performed well for patients with GMFCS level II. The results of this study showed that the LE CP-CAT displayed superior sensitivity to change than the PODCI and TUG scales after musculoskeletal surgery in children with CP. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  5. A computerized system for control and management of radionuclide inventory: application in nuclear medicine

    International Nuclear Information System (INIS)

    Hoory, S.; Levy, I.M.; Moskowitz, G.; Bandyopadhyay, D.; Vaugeois, J.C.

    1982-01-01

    An interactive computerized system for radioisotope management and instantaneous inventory is reported. The system is capable of handling operations such as filing, nuclear imaging and disposing of various radionuclides. All radiopharmaceutical transactions are achieved with the aid of a Prime 300 mini-computer of 192K words of high speed semi-conductor memory and over 120 mega bytes of disk storage. The system automatically corrects for the appropriate decay, monitors and updates the storage file after every subsequent study. The performed study is recorded in a special file, together with the time and data retrieved from the computer's real time clock at the time of the entry. The system provides an organized and complete bookkeeping of all records concerning radionuclide transactions. It is found to be simple, efficient, highly versatile, and drastically reduces the time of operation and errors in handling the radioisotope inventory. (author)

  6. Russian system of computerized analysis for licensing at atomic industry (SCALA) and its validation on ICSBEP handbook data and some burnup calculations

    International Nuclear Information System (INIS)

    Ivanova, T.; Nikolaev, M.; Polyakov, A.; Saraeva, T.; Tsiboulia, A.

    2000-01-01

    The System of Computerized Analysis for Licensing at Atomic industry (SCALA) is a Russian analogue of the well-known SCALE system. For criticality evaluations the ABBN-93 system is used with TWODANT and with joined American KENO and Russian MMK Monte-Carlo code MMKKENO. Using the same cross sections and input models, all these codes give results that coincide within the statistical uncertainties (for Monte-Carlo codes). Validation of criticality calculations using SCALA was performed using data presented in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Another task of the work was to test the burnup capability of SCALA system in complex geometry in compare with other codes. Benchmark models of VVER type reactor assemblies with UO 2 and MOX fuel including the cases with burnable gadolinium absorbers were calculated. KENO-VI and MMK codes were used for power distribution calculations, ORIGEN code was used for the isotopic kinetics calculations. (authors)

  7. Examination of the consistency and accuracy of computerized brachytherapy dose predictions

    International Nuclear Information System (INIS)

    Tolbert, D.D.; Reed, S.A.

    1981-01-01

    Four brachytherapy test cases were sent to representatives of commercial and non-commercial, computerized radiation oncology treatment planning systems. Four commercial systems are represented herein. The non-commercial, state-of-the-art systems represented are (in alphabetical order) BRACHY, ISODOS and RADCOMP. Mutual comparisons were made to examine consistency and a comparison with experimental measurements around a single source was made to examine accuracy. The systems represented are most consistent within 5 cm from the center of a single source, and within rays from the center making angles of greater than or equal to 20 0 relative to the source axis. Taking into account tissue absorption and scatter, the spatial uncertainty in the location of a particular isodose rate value is less than or equal to 0.7 mm for commercial systems and less than or equal to 0.5 mm for non-commercial systems

  8. Instrumentation and control activities at the electric power research institute to support computerized support systems

    International Nuclear Information System (INIS)

    Naser, J.

    1996-01-01

    Most nuclear power plants in the United States are operating with their original analog I and C equipment. This equipment requires increasing maintenance efforts to sustain systems performance. Decreasing availability of replacement parts and support organization for analog technology accentuate obsolescence problems and resultant O and M cost increases. Modern technology, especially digital systems, offers improved functionality, performance, and reliability; solutions to obsolescence of equipment; reduction in O and M costs; and the potential to enhance safety. Digital systems, including computerized support systems, with their inherent advantages will be implemented only if reliable and cost-effective implementation and licensing acceptance is achieved and if the upgraded systems supports reduced power production costs. EPRI and its member utilities are working together under the Integrated I and C Upgrade Initiative to address I and C issues. (author). 23 refs

  9. A practical appreciation of the implementation of a fully computerized monitoring and control system in N4 NFP series: An advanced instrumentation and control system

    Energy Technology Data Exchange (ETDEWEB)

    DaCruz, P. [Atos Origin, 4, Triton Square, Regent' s Place, London NW1 3HG (United Kingdom)

    2006-07-01

    Sema Group (acquired in February 2004 by Atos Origin) was selected by EDF to design, develop and supply this system, based on their product Advanced Data Acquisition and Control System (ADACS). The purpose of this paper is to give a practical appreciation from both the demand and supply perspectives of the implementation of the fully computerized Monitoring and Control systems. This is a joint presentation by EDF and Atos Origin based on their experiences of the N4 programme.

  10. A new Brief computerized cognitive screening battery (CompCogs for early diagnosis of Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Helenice Charchat Fichman

    Full Text Available Abstract Screening tests for early diagnosis of dementia are of great clinical relevance. The ideal test set must be brief and reliable, and should probe cognitive components impaired in Alzheimer's disease (AD. Objectives: To develop a new Computerized Cognitive Screening test (CompCogs, and to investigate its validity for the early diagnosis of AD, and evaluate its heuristic value in understanding the processing of information in AD. Methods: The computerized neuropsychological performance battery, originally including six tests, was applied in forty seven patients with probable mild AD and 97 controls matched for age and education. This computerized neuropsychological test battery, developed with MEL Professional, allows control of timing and order of stimuli presentation, as well as recording of response type and latency. A brief-screening version, CompCogs, was selected using the most discriminative neuropsychological test variables derived from logistic regression analysis. Full battery administration lasted about 40 minutes, while the CompCogs took only 15 minutes. Results: CompCogs included the Face test (correct response and Word and Forms with Short term memory tests (reaction time. CompCogs presented 91.8% sensitivity and 93.6% specificity for the diagnosis of AD using ROC analyses of AD diagnosis probability derived by logistic regression. Conclusions: CompCogs showed high validity for AD early diagnosis and, therefore, may be a useful alternative screening instrument.

  11. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  12. A programming system for a modular, flexible multicomputer system for the automatic control of automated test equipment

    International Nuclear Information System (INIS)

    Schmidt, J.

    1984-11-01

    The hardware used is operationally directed, consisting of largely self-functioning, micro-computing modules, combined together over a parallel systembus. For communication purposes between the modules and to synchronize their activities a multi microcomputing operating system is being developed which corresponds to the specific demands of computerized process-control (handling of real-word events under real-time conditions and operation of several parallel-running subprocesses). In order to program the user-specific test cycles a programming language has to be made available which can be coordinated with the operational range of specific test equipment in terms of commands and syntax and which can also easily be learned by operators having no specialised knowledge of data processing. With this objective in mind, a structural system is developed in this work, by the aid of which application-oriented programming languages can be implemented. The adaption of the programming system to a wide spectrum of applications in automatic testing is facilitated by its modular structure. The efficiency of the system is demonstrated by means of an industrial pilot-scale implementation. (orig./HP) [de

  13. Development of computerized supporting system for emergency response in nuclear power plant

    International Nuclear Information System (INIS)

    Lee, Jae Il

    1992-02-01

    In emergency situation of nuclear power plants, effective use of emergency operating procedures (EOPs) is a crucial part of the emergency response process. However, there are several problems in the emergency operating procedures because of the form of the written procedures. They are voluminous and complicate for effective references under high stress situation. Inevitably, it takes time that could be better spent employing measures to control and stabilize to select the correct procedures and apply the decision logic. In this study, a computerized supporting system has been developed to reduce the operator error possibility under emergency situations of nuclear power plant. Using on-line input parameters, the system can determine the status of the critical safety functions and can find appropriate procedures and necessary operator actions automatically. Moreover, the system can help the operator decision making in the core melt accident situation. By tracking the EOP in an on-line mode, most steps concerning checking or verifying plant state are processed automatically without operator participations. Therefore, the interactions between the system and the operator are simplified significantly and the possibility of human error is reduced

  14. Benefits of a relational database for computerized management

    International Nuclear Information System (INIS)

    Shepherd, W.W.

    1991-01-01

    This paper reports on a computerized relational database which is the basis for a hazardous materials information management system which is comprehensive, effective, flexible and efficient. The system includes product information for Material Safety Data Sheets (MSDSs), labels, shipping, and the environment and is used in Dowell Schlumberger (DS) operations worldwide for a number of programs including planning, training, emergency response and regulatory compliance

  15. Introduction to CRRIS: a computerized radiological risk investigation system for assessing atmospheric releases of radionuclides

    International Nuclear Information System (INIS)

    Baes, C.F. III; Miller, C.W.; Kocher, D.C.; Sjoreen, A.L.; Murphy, B.D.

    1985-08-01

    The CRRIS is a Computerized Radiological Risk Investigation System consisting of eight fully integrated computer codes which calculate environmental transport of atmospheric releases of radionuclides and resulting doses and health risks to individuals or populations. Each code may also be used alone for various assessment applications. Radionuclides are handled by the CRRIS either in terms of the released radionuclides or the exposure radionuclides which consist of both the released nuclides and decay products that grow in during environmental transport. The CRRIS is not designed to simulate short-term effects. 51 refs

  16. Dosimetric and non-dosimetric evaluation of PrecisePLAN computerized radiation treatment planning system

    International Nuclear Information System (INIS)

    Srinidhi, G.C.; Ramya, B.; Aswathi, Raj; Boban, Minu; Solomon, J.G.R; Vidyasagar, M.S.

    2008-01-01

    Cancer is a significant health care problem; on an average about half of all cancer patients are treated with radiation therapy worldwide. This mode of treatment uses complex technology that involves megavoltage radiation, computerized TPSs and delivery systems like MLCs, if not handled with the greatest of care, could lead to significant patient treatment errors and exposures of staff. As computer technology evolved and became more compact so did TPSs, while at the same time dose calculation algorithms and image display capabilities became more sophisticated. As part of the implementation of radiation therapy technology into clinical practice, it is important to recognize that such technology has inherent risks if not handled and administered properly

  17. Computerized strain-gauge plethysmography - An alternative method for the detection of lower limb deep venous thrombosis?

    Energy Technology Data Exchange (ETDEWEB)

    Elford, Julian; Wells, Irving; Cowie, Jim; Hurlock, Carol; Sanders, Hilary

    2000-01-01

    AIM: To test the ability of computerized strain-gauge plethysmography to act as a screening test for lower limb deep venous thrombosis (DVT). MATERIALS AND METHODS: Over an 8-month period, all patients referred to our Medical Assessment Unit with suspected lower limb DVT were considered for inclusion in the study. Each patient underwent both plethysmography and ascending venography within 24 h, and the presence or absence of thrombus in the popliteal, superficial femoral or iliac veins was noted. The results of the two tests were then used to determine the accuracy of computerized strain-gauge plethysmography in detecting above knee DVT. RESULTS: The screening tests and venograms of 239 patients referred with clinically suspected lower limb DVT were compared. The false negative rate of plethysmography was 15.4%, which is significantly different from the 4.8% claimed by the manufacturers of this device (P = 0.00003). CONCLUSIONS: In a population of acute admissions with suspected lower limb DVT, computerized strain-gauge plethysmography is not suitable for use as a screening test due to an unacceptably high proportion of false negative screens. J. Elford (2000)

  18. Computerized accountability program is operating - DYMCAS

    International Nuclear Information System (INIS)

    Combs, S.W.; Mee, W.T.

    1983-01-01

    The nuclear materials control and accountability program in the Oak Ridge Y-12 Plant has been placed on a computerized system identified as DYMCAS (Dynamic Special Nuclear Materials Control and Accountability System). The primary gola of the DYMCAS is to assist in detecting the diversion of special nuclear material (SNM). Secondly, the system is expected to assure quality inventory reconciliations both under normal and emergency situations. The system has been installed and was placed on active status in April 1982. Since that time numerous problems have surfaced and been resolved; i.e., delays of input, hardware breakdown, and misunderstandings of needs. An explanation of these problems, including examples and alterations that have made the system workable, are presented

  19. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  20. Post-hoc simulation study to adopt a computerized adaptive testing (CAT) for a Korean Medical License Examination.

    Science.gov (United States)

    Seo, Dong Gi; Choi, Jeongwook

    2018-05-17

    Computerized adaptive testing (CAT) has been adopted in license examinations due to a test efficiency and accuracy. Many research about CAT have been published to prove the efficiency and accuracy of measurement. This simulation study investigated scoring method and item selection methods to implement CAT in Korean medical license examination (KMLE). This study used post-hoc (real data) simulation design. The item bank used in this study was designed with all items in a 2017 KMLE. All CAT algorithms for this study were implemented by a 'catR' package in R program. In terms of accuracy, Rasch and 2parametric logistic (PL) model performed better than 3PL model. Modal a Posteriori (MAP) or Expected a Posterior (EAP) provided more accurate estimates than MLE and WLE. Furthermore Maximum posterior weighted information (MPWI) or Minimum expected posterior variance (MEPV) performed better than other item selection methods. In terms of efficiency, Rasch model was recommended to reduce test length. Simulation study should be performed under varied test conditions before adopting a live CAT. Based on a simulation study, specific scoring and item selection methods should be predetermined before implementing a live CAT.

  1. Overview and current management of computerized adaptive testing in licensing/certification examinations

    Directory of Open Access Journals (Sweden)

    Dong Gi Seo

    2017-07-01

    Full Text Available Computerized adaptive testing (CAT has been implemented in high-stakes examinations such as the National Council Licensure Examination-Registered Nurses in the United States since 1994. Subsequently, the National Registry of Emergency Medical Technicians in the United States adopted CAT for certifying emergency medical technicians in 2007. This was done with the goal of introducing the implementation of CAT for medical health licensing examinations. Most implementations of CAT are based on item response theory, which hypothesizes that both the examinee and items have their own characteristics that do not change. There are 5 steps for implementing CAT: first, determining whether the CAT approach is feasible for a given testing program; second, establishing an item bank; third, pretesting, calibrating, and linking item parameters via statistical analysis; fourth, determining the specification for the final CAT related to the 5 components of the CAT algorithm; and finally, deploying the final CAT after specifying all the necessary components. The 5 components of the CAT algorithm are as follows: item bank, starting item, item selection rule, scoring procedure, and termination criterion. CAT management includes content balancing, item analysis, item scoring, standard setting, practice analysis, and item bank updates. Remaining issues include the cost of constructing CAT platforms and deploying the computer technology required to build an item bank. In conclusion, in order to ensure more accurate estimations of examinees’ ability, CAT may be a good option for national licensing examinations. Measurement theory can support its implementation for high-stakes examinations.

  2. A prototype of a computerized patient record.

    Science.gov (United States)

    Adelhard, K; Eckel, R; Hölzel, D; Tretter, W

    1995-01-01

    Computerized medical record systems (CPRS) should present user and problem oriented views of the patient file. Problem lists, clinical course, medication profiles and results of examinations have to be recorded in a computerized patient record. Patient review screens should give a synopsis of the patient data to inform whenever the patient record is opened. Several different types of data have to be stored in a patient record. Qualitative and quantitative measurements, narratives and images are such examples. Therefore, a CPR must also be able to handle these different data types. New methods and concepts appear frequently in medicine. Thus a CPRS must be flexible enough to cope with coming demands. We developed a prototype of a computer based patient record with a graphical user interface on a SUN workstation. The basis of the system are a dynamic data dictionary, an interpreter language and a large set of basic functions. This approach gives optimal flexibility to the system. A lot of different data types are already supported. Extensions are easily possible. There is also almost no limit concerning the number of medical concepts that can be handled by our prototype. Several applications were built on this platform. Some of them are presented to exemplify the patient and problem oriented handling of the CPR.

  3. Nuclear computerized library for assessing reactor reliability (NUCLARR): User's guide: Part 3, NUCLARR system description

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Gentillon, C.D.; Gertman, D.I.; Beers, G.H.; Galyean, W.J.; Gilbert, B.G.

    1988-06-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal micro-computer. NUCLARR can be used by the end user to furnish data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume IV of this series is the User's Guide for operating the NUCLARR software and is presented in three parts. This document, Part 3: NUCLARR System Description, provides an in-depth discussion of the design characteristics and special features of the NUCLARR software. Part 3 also presents the organization of the data base structures and techniques used to manipulate the data

  4. Young Learners' Response Processes When Taking Computerized Tasks for Speaking Assessment

    Science.gov (United States)

    Lee, Shinhye; Winke, Paula

    2018-01-01

    We investigated how young language learners process their responses on and perceive a computer-mediated, timed speaking test. Twenty 8-, 9-, and 10-year-old non-native English-speaking children (NNSs) and eight same-aged, native English-speaking children (NSs) completed seven computerized sample TOEFL® Primary™ speaking test tasks. We investigated…

  5. Development of computerized stocktaking system in mine surveying for ore mineral volume calculation in covered storehouses

    Science.gov (United States)

    Valdman, V. V.; Gridnev, S. O.

    2017-10-01

    The article examines into the vital issues of measuring and calculating the raw stock volumes in covered storehouses at mining and processing plants. The authors bring out two state-of-the-art high-technology solutions: 1 - to use the ground-based laser scanning system (the method is reasonably accurate and dependable, but costly and time consuming; it also requires the stoppage of works in the storehouse); 2 - to use the fundamentally new computerized stocktaking system in mine surveying for the ore mineral volume calculation, based on the profile digital images. These images are obtained via vertical projection of the laser plane onto the surface of the stored raw materials.

  6. Design and validation of a questionnaire to evaluate the usability of computerized critical care information systems.

    Science.gov (United States)

    von Dincklage, Falk; Lichtner, Gregor; Suchodolski, Klaudiusz; Ragaller, Maximilian; Friesdorf, Wolfgang; Podtschaske, Beatrice

    2017-08-01

    The implementation of computerized critical care information systems (CCIS) can improve the quality of clinical care and staff satisfaction, but also holds risks of disrupting the workflow with consecutive negative impacts. The usability of CCIS is one of the key factors determining their benefits and weaknesses. However, no tailored instrument exists to measure the usability of such systems. Therefore, the aim of this study was to design and validate a questionnaire that measures the usability of CCIS. Following a mixed-method design approach, we developed a questionnaire comprising two evaluation models to assess the usability of CCIS: (1) the task-specific model rates the usability individually for several tasks which CCIS could support and which we derived by analyzing work processes in the ICU; (2) the characteristic-specific model rates the different aspects of the usability, as defined by the international standard "ergonomics of human-system interaction". We tested validity and reliability of the digital version of the questionnaire in a sample population. In the sample population of 535 participants both usability evaluation models showed a strong correlation with the overall rating of the system (multiple correlation coefficients ≥0.80) as well as a very high internal consistency (Cronbach's alpha ≥0.93). The novel questionnaire is a valid and reliable instrument to measure the usability of CCIS and can be used to study the influence of the usability on their implementation benefits and weaknesses.

  7. Feasibility of computerized screening for intimate partner violence in a pediatric emergency department.

    Science.gov (United States)

    Scribano, Philip V; Stevens, Jack; Marshall, Jessica; Gleason, Erica; Kelleher, Kelly J

    2011-08-01

    This study aimed to evaluate the feasibility of caregiver-initiated computerized screening in a pediatric emergency department (ED) to identify home safety risks, with a specific emphasis on intimate partner violence (IPV). Home safety screening kiosks were developed using information technology as the first step in a plan to decrease family violence. Caregivers self-initiated a standard-of-care screening process that included both non-IPV and IPV items. An ED social worker received an automated text page and printed summary of the findings when a caregiver endorsed IPV. System activity was tracked by comparing frequency of completed screens to the daily ED census and by determining the percentage of completed screens that were positive for IPV. The reliability of the technology was evaluated as percentage of days of system downtime. Meetings with ED personnel and direct observations of families were conducted to identify potential barriers and successes to the technology utilization. During a 15-month period, 13,057 computerized screens occurred, with a 4-fold increase in the computerized screening rate after ED triage nurses became champions of these efforts. Fourteen percent of the computerized screens were positive for IPV. The reliability of the technology was considered quite high, with rare system downtime (4.2% of days) reported during the 15 months. There were several themes identified by caregivers and providers regarding barriers to successful use of the safety screening. A reliable, caregiver-initiated system is possible to offer consistent opportunity to conduct unobtrusive, private screening for IPV and other home safety concerns.

  8. Computerized reactor power regulation with logarithmic controller

    International Nuclear Information System (INIS)

    Gossanyi, A.; Vegh, E.

    1982-11-01

    A computerized reactor control system has been operating at a 5 MW WWR-SM research reactor in the Central Research Institute for Physics, Budapest, for some years. This paper describes the power controller used in the SPC operating mode of the system, which operates in a 5-decade wide power range with +-0.5% accuracy. The structure of the controller easily limits the minimal reactor period and produces a reactor transient with constant period if the power demand changes. (author)

  9. Computerized literature reference system: use of an optical scanner and optical character recognition software.

    Science.gov (United States)

    Lossef, S V; Schwartz, L H

    1990-09-01

    A computerized reference system for radiology journal articles was developed by using an IBM-compatible personal computer with a hand-held optical scanner and optical character recognition software. This allows direct entry of scanned text from printed material into word processing or data-base files. Additionally, line diagrams and photographs of radiographs can be incorporated into these files. A text search and retrieval software program enables rapid searching for keywords in scanned documents. The hand scanner and software programs are commercially available, relatively inexpensive, and easily used. This permits construction of a personalized radiology literature file of readily accessible text and images requiring minimal typing or keystroke entry.

  10. Quality of computerized blast load simulation for non-linear dynamic ...

    African Journals Online (AJOL)

    Quality of computerized blast load simulation for non-linear dynamic response ... commercial software system and a special-purpose, blast-specific software product to ... depend both on the analysis model of choice and the stand-off distances.

  11. Computerized systems for on-line management of failures: a state-of-the-art discussion of alarm systems and diagnostic systems applied in the nuclear industry

    International Nuclear Information System (INIS)

    Kim, I.S.

    1994-01-01

    It is now well perceived in the nuclear industry that improving plant information systems is vital for enhancing the operational safety of nuclear power plants. Considerable work is underway worldwide to support operators' decision-making, particularly in their difficult tasks of managing process anomalies on-line. The work includes development of (1) advanced alarm systems, such as various kinds of computer-based alarm processing systems, Critical Function Monitoring System, Success Path Monitoring System and Safety Assessment System II, and (2) real-timer diagnostic systems, such as Disturbance Analysis System, Maryland Operator Advisory System II, Model-Integrated Diagnostic Analysis System, Diagnosis System using Knowledge Engineering Technique, Detailed Diagnosis, and Operator Advisor System. This paper presents a state-of-the-art review of plant information systems for on-line management of failures in nuclear power plants, focusing on the methodological features of computerized alarm systems and diagnostic systems. (author)

  12. The process of development of a prioritization tool for a clinical decision support build within a computerized provider order entry system: Experiences from St Luke's Health System.

    Science.gov (United States)

    Wolf, Matthew; Miller, Suzanne; DeJong, Doug; House, John A; Dirks, Carl; Beasley, Brent

    2016-09-01

    To establish a process for the development of a prioritization tool for a clinical decision support build within a computerized provider order entry system and concurrently to prioritize alerts for Saint Luke's Health System. The process of prioritizing clinical decision support alerts included (a) consensus sessions to establish a prioritization process and identify clinical decision support alerts through a modified Delphi process and (b) a clinical decision support survey to validate the results. All members of our health system's physician quality organization, Saint Luke's Care as well as clinicians, administrators, and pharmacy staff throughout Saint Luke's Health System, were invited to participate in this confidential survey. The consensus sessions yielded a prioritization process through alert contextualization and associated Likert-type scales. Utilizing this process, the clinical decision support survey polled the opinions of 850 clinicians with a 64.7 percent response rate. Three of the top rated alerts were approved for the pre-implementation build at Saint Luke's Health System: Acute Myocardial Infarction Core Measure Sets, Deep Vein Thrombosis Prophylaxis within 4 h, and Criteria for Sepsis. This study establishes a process for developing a prioritization tool for a clinical decision support build within a computerized provider order entry system that may be applicable to similar institutions. © The Author(s) 2015.

  13. Computerized map-based information management system for natural resource management

    Energy Technology Data Exchange (ETDEWEB)

    Miller, K.

    1995-12-01

    Federal agencies, states and resource managers have control and stewardship responsibility over a significant inventory of natural resources. A number of federal regulations require the review, protection and preservation of natural resource protection. Examples of such actions include the reauthorization of the Clean Water Act and the modification of the National Contingency Plan to incorporate the requirements of the Oil Pollution Act of 1990. To successfully preserve conserve and restore natural resources on federal reservations, and state and private lands, and to comply with Federal regulations designed to protect natural resources located on their sites, and the type of information on these resources required by environmental regulations. This paper presents an approach using a computerized, graphical information management system to catalogue and track data for the management of natural resources under Federal and state regulations, and for promoting resource conservation, preservation and restoration. The system is designed for use by Federal facility resource managers both for the day-to-day management of resources under their control, and for the longer-term management of larger initiatives, including restoration of significant or endangered resources, participation in regional stewardship efforts, and general ecosystem management. The system will be valuable for conducting natural resource baseline inventories an implementing resource management plans on lands other than those controlled by the Federal government as well. The system can provide a method for coordinating the type of natural resource information required by major federal environmental regulations--thereby providing a cost-effective means for managing natural resource information.

  14. Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: Methods of a decision-maker-researcher partnership systematic review

    OpenAIRE

    Wilczynski Nancy L; Haynes R Brian

    2010-01-01

    Abstract Background Computerized clinical decision support systems are information technology-based systems designed to improve clinical decision-making. As with any healthcare intervention with claims to improve process of care or patient outcomes, decision support systems should be rigorously evaluated before widespread dissemination into clinical practice. Engaging healthcare providers and managers in the review process may facilitate knowledge translation and uptake. The objective of this...

  15. Computerized content analysis of some adolescent writings of Napoleon Bonaparte: a test of the validity of the method.

    Science.gov (United States)

    Gottschalk, Louis A; DeFrancisco, Don; Bechtel, Robert J

    2002-08-01

    The aim of this study was to test the validity of a computer software program previously demonstrated to be capable of making DSM-IV neuropsychiatric diagnoses from the content analysis of speech or verbal texts. In this report, the computer program was applied to three personal writings of Napoleon Bonaparte when he was 12 to 16 years of age. The accuracy of the neuropsychiatric evaluations derived from the computerized content analysis of these writings of Napoleon was independently corroborated by two biographers who have described pertinent details concerning his life situations, moods, and other emotional reactions during this adolescent period of his life. The relevance of this type of computer technology to psychohistorical research and clinical psychiatry is suggested.

  16. The Characteristics of Personal Order Sets in a Computerized Physician Order Entry System at a Community Hospital

    OpenAIRE

    Thomas, Sean M.; Davis, Daniel C.

    2003-01-01

    Personal order sets (POS) have been touted as important for the success of a computerized physician order entry (CPOE) system1. However, POS may systematize practice variability and are difficult to centrally administer. Few studies have looked at the characteristics and use of POS in a community hospital. We examined how POS are used at the Queen’s Medical Center (QMC). POS are an important part of the success of the QMC CPOE, but have definite disadvantages.

  17. Mobile Computerized Procedure System for the Improved Situation Awareness among Field Workers and Main Control Room Operators

    International Nuclear Information System (INIS)

    Lee, Sungjin; Seong, Nokyu; Jung, Yeonsub

    2013-01-01

    This paper explains the technical issues of the mobile CPS (m-CPS) in the conceptual development stage. The proposed m-CPS can be developed with many recent technologies in the various industry fields based on CRI CPS. Performance and stability of CRI CPS have been tested several times until now. It is expected that more human errors can be reduced by the m-CPS through improved situation awareness and human performance tools for local workers and MCR operators. Some considerations as well as mentioned ones will be reflected in the m-CPS development. Human errors can occur during the test and maintenance of the generator, safety injection system and reactor coolant inventory in nuclear power plants (NPPs). Most of human errors have been occurred by the omission of the prevention techniques such as the self-check, the peer-check, the concurrent verification and etc. Another important reason is the insufficient information sharing among main control room (MCR) operators and field workers. Various field service automation tools have been developed with recent information technology in many countries. APR1400 computerized procedure system (CPS) has been developed for the MCR operators of Shin-Kori 3 and 4 units. Especially, the concurrent verification support design is applied in the construction project of Shin-Hanul 1 and 2 CPS. KHNP central research institute (CRI) expects that the extended application of CPS including the field activity, that is a kind of mobile CPS, can enhance the reduction of human errors

  18. Computerized operator decision aids

    International Nuclear Information System (INIS)

    Long, A.B.

    1984-01-01

    This article explores the potential benefits associated with the use of computers in nuclear plants by the operating crew as an aid in making decisions. Pertinent findings are presented from recently completed projects to establish the context in which operating decisions have to be made. Key factors influencing the decision-making process itself are also identified. Safety parameter display systems, which are being implemented in various forms by the nuclear industry, are described within the context of decision making. In addition, relevant worldwide research and development activities are examined as potential enhancements to computerized operator decision aids to further improve plant safety and availability

  19. Computerized health information and the demand for medical care.

    Science.gov (United States)

    Wagner, Todd H; Jimison, Holly B

    2003-01-01

    Consumer health information, once the domain of books and booklets, has become increasingly digitized and available on the Internet. This study assessed the effect of using computerized health information on consumers' demand for medical care. The dependent variable was self-reported number of visits to the doctor in the past year. The key independent variable was the use of computerized health information, which was treated as endogenous. We tested the effect of using computerized health information on physician visits using ordinary least squares, instrumental variables, fixed effects, and fixed-effects instrumental variables models. The instrumental variables included exposure to the Healthwise Communities Project, a community-wide health information intervention; computer ownership; and Internet access. Random households in three cities were mailed questionnaires before and after the Healthwise Communities Project. In total, 5909 surveys were collected for a response rate of 54%. In both the bivariate and the multivariate analyses, the use of computerized health information was not associated with self-reported entry into care or number of visits. The instrumental variables models also found no differences, with the exception that the probability of entering care was significantly greater with the two-stage conditional logit model (P information is intuitively appealing, we found little evidence of an association between using a computer for health information and self-reported medical visits in the past year. This study used overall self-reported utilizations as the dependent variable, and more research is needed to determine whether health information affects the health production function in other important ways, such as the location of care, the timing of getting care, or the intensity of treatment.

  20. Método computadorizado para medida da acuidade visual A computerized method for visual acuity assessment

    Directory of Open Access Journals (Sweden)

    Patrícia Katayama Kjaer Arippol

    2006-12-01

    Full Text Available OBJETIVO: Elaborar e validar teste computadorizado para medida da acuidade visual de escolares. MÉTODOS: Foi elaborado teste computadorizado para determinação da acuidade visual utilizando os padrões das tabelas logarítmicas impressas adotadas na clínica oftalmológica. Foram avaliados 90 alunos da primeira série do ensino básico, oito estudantes do curso de Tecnologia Oftálmica da UNIFESP-EPM e 10 pacientes do ambulatório de Estrabismo do Departamento de Oftalmologia da UNIFESP-EPM. Todos os sujeitos foram avaliados pelo mesmo examinador e submetidos ao exame de acuidade visual monocular, pela tabela logarítmica de optotipos E impressa e do novo teste computadorizado no mesmo momento. Os participantes forneceram os seus consentimentos após esclarecimento. RESULTADOS: As análises estatísticas revelaram correlação excelente (r>0,75 entre os dois métodos, apesar da leve tendência apresentada pelo teste computadorizado em superestimar a acuidade visual quando comparado com o padrão-ouro. O teste computadorizado apresentou sensibilidade de 100% e especificidade de 94%. CONCLUSÕES: Os resultados obtidos nos permitem dizer que o teste computadorizado pode ser utilizado como novo recurso para triagem da qualidade visual dos escolares, por ser método rápido, de fácil aplicação, barato, automático e atrativo para as crianças. A automatização desvincula o aplicador da interpretação das respostas dadas pelo aluno testado, garante padronização do procedimento, que favorece as análises de acompanhamento e pode ser realizado por diferentes examinadores. Para melhor compreensão da efetividade do teste como instrumento de triagem visual, seria interessante instituí-lo nas escolas do curso básico, após treinamento dos professores para sua aplicação.PURPOSE: To elaborate and to validate a computerized test for visual acuity screening of school-age children. METHODS: We have created a computerized test for visual acuity

  1. Computerized tomography using high resolution X-ray imaging system with a microfocus source

    International Nuclear Information System (INIS)

    Zaprazny, Z.; Korytar, D.; Konopka, P.; Ac, V.; Bielecki, J.

    2011-01-01

    In recent years there is an effort to image an internal structure of an object by using not only conventional 2D X-ray radiography but also using high resolution 3D tomography which is based on reconstruction of multiple 2D projections at various angular positions of the object. We have previously reported [1] the development and basic parameters of a high resolution x-ray imaging system with a microfocus source. We report the recent progress using this high resolution X-ray laboratory system in this work. These first findings show that our system is particularly suitable for light weight and nonmetallic objects such as biological objects, plastics, wood, paper, etc. where phase contrast helps to increase the visibility of the finest structures of the object. Phase-contrast X-ray Computerized Tomography is of our special interest because it is an emerging imaging technique that can be implemented at third generation synchrotron radiation sources and also in laboratory conditions using a microfocus X-ray tube or beam conditioning optics. (authors)

  2. A novel approach to sports concussion assessment: Computerized multilimb reaction times and balance control testing.

    Science.gov (United States)

    Vartiainen, Matti V; Holm, Anu; Lukander, Jani; Lukander, Kristian; Koskinen, Sanna; Bornstein, Robert; Hokkanen, Laura

    2016-01-01

    Mild traumatic brain injuries (MTBI) or concussions often result in problems with attention, executive functions, and motor control. For better identification of these diverse problems, novel approaches integrating tests of cognitive and motor functioning are needed. The aim was to characterize minor changes in motor and cognitive performance after sports-related concussions with a novel test battery, including balance tests and a computerized multilimb reaction time test. The cognitive demands of the battery gradually increase from a simple stimulus response to a complex task requiring executive attention. A total of 113 male ice hockey players (mean age = 24.6 years, SD = 5.7) were assessed before a season. During the season, nine concussed players were retested within 36 hours, four to six days after the concussion, and after the season. A control group of seven nonconcussed players from the same pool of players with comparable demographics were retested after the season. Performance was measured using a balance test and the Motor Cognitive Test battery (MotCoTe) with multilimb responses in simple reaction, choice reaction, inhibition, and conflict resolution conditions. The performance of the concussed group declined at the postconcussion assessment compared to both the baseline measurement and the nonconcussed controls. Significant changes were observed in the concussed group for the multilimb choice reaction and inhibition tests. Tapping and balance showed a similar trend, but no statistically significant difference in performance. In sports-related concussions, complex motor tests can be valuable additions in assessing the outcome and recovery. In the current study, using subtasks with varying cognitive demands, it was shown that while simple motor performance was largely unaffected, the more complex tasks induced impaired reaction times for the concussed subjects. The increased reaction times may reflect the disruption of complex and integrative cognitive

  3. Radiation exposure of the gonads in infant brain computerized tomography

    International Nuclear Information System (INIS)

    Berndt, L.; Rosenkranz, G.; Tellkamp, H.

    1988-01-01

    In 61 babies and infants the gonadal dose due to brain computerized tomography was determined over the symphysis by thermoluminescent dosimetry. The average radiation dose was 43 mGy corresponding with data reported. Shielding of the testes in infants is an additional burden and worth discussing because of the low absolute gonadal dose

  4. Cumulative Effects of Concussion History on Baseline Computerized Neurocognitive Test Scores: Systematic Review and Meta-analysis.

    Science.gov (United States)

    Alsalaheen, Bara; Stockdale, Kayla; Pechumer, Dana; Giessing, Alexander; He, Xuming; Broglio, Steven P

    It is unclear whether individuals with a history of single or multiple clinically recovered concussions exhibit worse cognitive performance on baseline testing compared with individuals with no concussion history. To analyze the effects of concussion history on baseline neurocognitive performance using a computerized neurocognitive test. PubMed, CINAHL, and psycINFO were searched in November 2015. The search was supplemented by a hand search of references. Studies were included if participants completed the Immediate Post-concussion Assessment and Cognitive Test (ImPACT) at baseline (ie, preseason) and if performance was stratified by previous history of single or multiple concussions. Systematic review and meta-analysis. Level 2. Sample size, demographic characteristics of participants, as well as performance of participants on verbal memory, visual memory, visual-motor processing speed, and reaction time were extracted from each study. A random-effects pooled meta-analysis revealed that, with the exception of worsened visual memory for those with 1 previous concussion (Hedges g = 0.10), no differences were observed between participants with 1 or multiple concussions compared with participants without previous concussions. With the exception of decreased visual memory based on history of 1 concussion, history of 1 or multiple concussions was not associated with worse baseline cognitive performance.

  5. 45 CFR 310.30 - Under what circumstances would FFP be suspended or disallowed in the costs of Computerized Tribal...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Under what circumstances would FFP be suspended or... SYSTEMS AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.30 Under what circumstances would FFP be suspended or disallowed in the costs of Computerized Tribal IV-D...

  6. Field testing and applications of the Ultrasonic Ranging and Data (USRAD) System

    International Nuclear Information System (INIS)

    Dickerson, K.S.; Pickering, D.A.; Blair, M.S.; Espegren, M.L.; Nyquist, J.E.

    1989-01-01

    The Ultrasonic Ranging and Data (USRAD) System is a patented, computerized data acquisition system developed to relate the radiological surveyor's precise physical location to instantaneous radiation data taken during walk-on surveys. The USRAD System incorporates three technologies: radio frequency communications, ultrasonics, and microcomputers. Initial field testing of the USRAD System has resulted in several improvements to walk-on radiological surveys including real-time position data, reproducible survey results, on-site verification of survey coverage, on-site data reduction and graphics, and permanent data storage on magnetic media. Although the USRAD System was developed specifically for use with a gamma-ray detector, it is adaptable to other instruments. Applications of the USRAD System may include verification of remediated and uncontaminated areas, emergency response in mapping pollutant locations after accidents, and characterization of hazardous waste areas. 2 refs., 8 figs

  7. Computerized transportation model for the NRC Physical Protection Project. Versions I and II

    International Nuclear Information System (INIS)

    Anderson, G.M.

    1978-01-01

    Details on two versions of a computerized model for the transportation system of the NRC Physical Protection Project are presented. The Version I model permits scheduling of all types of transport units associated with a truck fleet, including truck trailers, truck tractors, escort vehicles and crews. A fixed-fleet itinerary construction process is used in which iterations on fleet size are required until the service requirements are satisfied. The Version II model adds an aircraft mode capability and provides for a more efficient non-fixed-fleet itinerary generation process. Test results using both versions are included

  8. Computerized tomography in orthopaedics and traumatology

    International Nuclear Information System (INIS)

    Boettger, E.; Heckl, R.; Rehabilitations-Krankenhaus Langensteinbach, Karlsbad

    1981-01-01

    Computerized tomography in traumatology is the selected method for the indications mentioned, so that angiographic investigations are only necessary in exceptional cases. Computerized tomography is also better than other methods when diagnozing soft part tumours, however, angiography is still indicated preoperatively for individual cases. CT is only good as additional help to conventional diagnostics with bone tumours. The differential diagnosis cysts-tumour is possible using contrast medium injections. The frequently large soft part share of tumours is recognizable with osteolytic tumours so that a better irradiation and operation planning can be effected. Diseases in the spinal canal can only be assessed with reservation using modern equipment. Lumbar dislocations of the disk can mostly not be sufficiently determined. Perivertebral abscesses can be certainly detected using computerized tomography. This is particularly so for abscesses prior to calcification. (orig.) [de

  9. A computerized accountability program is operating - DYMCAS

    International Nuclear Information System (INIS)

    Combs, S.W.; Mee, W.T.

    1983-01-01

    The nuclear materials control and accountability program in the Oak Ridge Y-12 Plant has been placed on a computerized system identified as DYMCAS (Dynamic Special Nuclear Materials Control and Accountability System). The primary goal of the DYMCAS is to assist in detecting the diversion of special nuclear material (SNM). Secondly, the system is expected to assure quality inventory reconciliations both under normal and emergency situations. The system has been installed and was placed on active status in April 1982. Since that time numerous problems have surfaced and been resolved; i.e., delays of input, hardware breakdown, and misunderstandings of needs. An explanation of these problems, including examples and alterations that have made the system workable, are presented

  10. Computerized information system on the impacts of coal-fired energy development in the Southwest

    International Nuclear Information System (INIS)

    Layton, D.W.

    1975-01-01

    An important part of the process of assessing the environmental impacts of coal-fired energy development in the Southwest is the transfer of information between electric utilities, federal agencies, and the interested public. There are, however, several problems associated with the transfer of information among the different groups. The acquisition of factual material on power projects by the interested public, for example, is adversely affected by the sufficiency, convenience, and credibility of present sources. Efforts of electric utilities and federal agencies to effectively communicate impact information are hindered by the inability of existing sources to selectively transfer information and to rapidly transmit information on the cumulative impacts of many combinations of power plants. This research concerns the development and evaluation of a computerized information system designed to selectively transfer information on both the cumulative and individual impacts of several electric generating facilities located in the southwestern United States. The information system incorporates features of management information systems, environmental information systems, and an issue-oriented system developed at The University of Illinois, making it a hybrid system capable of communicating impact information derived from a variety of sources

  11. Test-retest of computerized health status questionnaires frequently used in the monitoring of knee osteoarthritis

    DEFF Research Database (Denmark)

    Gudbergsen, Henrik; Bartels, Else M.; Krusager, Peter

    2011-01-01

    ABSTRACT: BACKGROUND: To compare data based on touch screen to data based on traditional paper versions of questionnaires frequently used to examine patient reported outcomes in knee osteoarthritis patients and to examine the impact of patient characteristics on this comparison METHODS: Participa......ABSTRACT: BACKGROUND: To compare data based on touch screen to data based on traditional paper versions of questionnaires frequently used to examine patient reported outcomes in knee osteoarthritis patients and to examine the impact of patient characteristics on this comparison METHODS...... subgroups, completing either the paper or touch screen version first. Mean, mean differences (95% CI), median, median differences and Intraclass Correlation Coefficients (ICCs) were calculated for all questionnaires. RESULTS: ICCs between data based on computerized and paper versions ranged from 0.86 to 0.......99. Analysis revealed a statistically significant difference between versions of the ADL Taxonomy, but not for the remaining questionnaires. Age, computer experience or education-level had no significant impact on the results. The computerized questionnaires were reported to be easier to use. CONCLUSION...

  12. Computerized spirography and roentgenopneumopolygraphy in diagnosis of tracheobroncheal dyskinesia

    International Nuclear Information System (INIS)

    Gladkij, A.V.; Gul'ko, S.I.; Vyalyj, N.P.; Salivon, A.P.; Orlovskaya, I.I.

    1991-01-01

    The results of comprehensive examination of respiratory organs in 103 patients with hypotonic dyskinesia syndrome of trachea and large bronchi were presented. The comprehensive examination included computerized spirography and roentgenopneumopolygraphy with additional tests: exercise and drug. It was shown that the conducted comprehensive examination helped to receive an information about breathh physiology, to diagnose tracheobroncheal dyskinesia and to evaluate the degree of ventilation disorders

  13. A case of multiple intracranial tuberculoma followed by serial computerized tomography

    International Nuclear Information System (INIS)

    Kummer, R. von; Storch, B.; Krause, K.H.; Rauch, H.

    1981-01-01

    This is the case report of an Indian living in Europe who suffered from multiple cerebral tuberculomes in connexion with extrapulmonal tuberculosis. The retrogression of the inflammatory granulomes and the surrounding cerebral edema by treatment with tuberculostatics and Dexamethasone was observed by means of computerized tomography (CT) over a period of 8 months. The value of CT in the diagnosis and treatment of cerebral tuberculomes is discussed. The diagnosis of cerebral tuberculomes is difficult as neither the clinical picture nor additional neuroradiological tests ensure safe delimitation against other intracranial growths. In how far this situation has changed by the introduction of CT into diagnostics is discussed by the example of serial computerized tomography on a patient with multiple cerebral tuberculomes. (orig.) [de

  14. Protocol for implementation of family health history collection and decision support into primary care using a computerized family health history system

    Directory of Open Access Journals (Sweden)

    Agbaje Astrid B

    2011-10-01

    Full Text Available Abstract Background The CDC's Family History Public Health Initiative encourages adoption and increase awareness of family health history. To meet these goals and develop a personalized medicine implementation science research agenda, the Genomedical Connection is using an implementation research (T3 research framework to develop and integrate a self-administered computerized family history system with built-in decision support into 2 primary care clinics in North Carolina. Methods/Design The family health history system collects a three generation family history on 48 conditions and provides decision support (pedigree and tabular family history, provider recommendation report and patient summary report for 4 pilot conditions: breast cancer, ovarian cancer, colon cancer, and thrombosis. All adult English-speaking, non-adopted, patients scheduled for well-visits are invited to complete the family health system prior to their appointment. Decision support documents are entered into the medical record and available to provider's prior to the appointment. In order to optimize integration, components were piloted by stakeholders prior to and during implementation. Primary outcomes are change in appropriate testing for hereditary thrombophilia and screening for breast cancer, colon cancer, and ovarian cancer one year after study enrollment. Secondary outcomes include implementation measures related to the benefits and burdens of the family health system and its impact on clinic workflow, patients' risk perception, and intention to change health related behaviors. Outcomes are assessed through chart review, patient surveys at baseline and follow-up, and provider surveys. Clinical validity of the decision support is calculated by comparing its recommendations to those made by a genetic counselor reviewing the same pedigree; and clinical utility is demonstrated through reclassification rates and changes in appropriate screening (the primary outcome

  15. Usability testing of a computerized communication tool in a diverse urban pediatric population.

    Science.gov (United States)

    Tsimicalis, Argerie; Stone, Patricia W; Bakken, Suzanne; Yoon, Sunmoo; Sands, Stephen; Porter, Rechelle; Ruland, Cornelia

    2014-01-01

    Developed in Norway, Sisom is an interactive, rigorously tested, computerized, communication tool designed to help children with cancer express their perceived symptoms/problems. Children travel virtually from island to island rating their symptoms/problems. While Sisom has been found to significantly improve communication in patient consultations in Norway, usability testing is warranted with US children prior to further use in research studies. The objective of this study was to determine the usability of Sisom in a sample of English- and Spanish-speaking children in an urban US community. A mixed-methods usability study was conducted with a purposive sample of healthy children and children with cancer. Semistructured interviews were used to assess healthy children's symptom recognition. Children with cancer completed 8 usability tasks captured with Morae 3.3 software. Data were downloaded, transcribed, and analyzed descriptively. Four healthy children and 8 children with cancer participated. Of the 44 symptoms assessed, healthy children recognized 15 (34%) pictorial symptoms immediately or indicated 13 (30%) pictures were good representations of the symptom. Six children with cancer completed all tasks. All children navigated successfully from one island to the next, ranking their symptom/problem severity, clicking the magnifying glass for help, or asking the researcher for assistance. All children were satisfied with the aesthetics and expressed an interest in using Sisom to communicate their symptoms/problems. A few minor suggestions for improvement and adjustment may optimize the use of Sisom for US children. Sisom may help clinicians overcome challenges assessing children's complex symptoms/problems in a child-friendly manner.

  16. Dose evaluation in diagnostic for computerized tomography

    International Nuclear Information System (INIS)

    Flores, W.; Borges, J.C.; Mota, H.

    1998-01-01

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  17. Investigation of the Usability of Computerized Critical Care Information Systems in Germany.

    Science.gov (United States)

    von Dincklage, Falk; Suchodolski, Klaudiusz; Lichtner, Gregor; Friesdorf, Wolfgang; Podtschaske, Beatrice; Ragaller, Maximilian

    2017-01-01

    The term "usability" describes how effectively, efficiently, and with what level of user satisfaction an information system can be used to accomplish specific goals. Computerized critical care information systems (CCISs) with high usability increase quality of care and staff satisfaction, while reducing medication errors. Conversely, systems lacking usability can interrupt clinical workflow, facilitate errors, and increase charting time. The aim of this study was to investigate and compare usability across CCIS currently used in Germany. In this study, German intensive care unit (ICU) nurses and physicians completed a specialized, previously validated, web-based questionnaire. The questionnaire assessed CCIS usability based on three rating models: an overall rating of the systems, a model rating technical usability, and a model rating task-specific usability. We analyzed results from 535 survey participants and compared eight different CCIS commonly used in Germany. Our results showed that usability strongly differs across the compared systems. The system ICUData had the best overall rating and technical usability, followed by the platforms ICM and MetaVision. The same three systems performed best in the rating of task-specific usability without significant differences between each other. Across all systems, overall ratings were more dependent on ease-of-use aspects than on aspects of utility/functionality, and the general scope of the functions offered was rated better than how well the functions are realized. Our results suggest that manufacturers should shift some of their effort away from the development of new features and focus more on improving the ease-of-use and quality of existing features.

  18. A computerized expert system for mammography

    International Nuclear Information System (INIS)

    Jackson, V.P.; Dines, K.A.; Bassett, L.W.

    1988-01-01

    The authors have developed a computer-based expert system to aid in the interpretation of mammograms, breast sonograms, and clinical findings. The radiologist enters clinical and image data into the artificial intelligence system and receives a prediction of the etiology of lesions seen on breast imaging studies. This prototype interactive system has undergone preliminary clinical testing and evaluation. Ultimately, a more refined and complex system will be of value in mammography education, for general radiologists without ready access to mammography experts, for paramedical personnel, and for all mammographers in need of a breast imaging database and reporting systems

  19. A study on operators' cognitive response characteristics to the computerized working environment

    International Nuclear Information System (INIS)

    Lee, Yong Hee; Lee, Jang Soo; Suh, Sang Moon; Lee, Hyun Cheol; Jung, Kwang Tae; Lee, Dhong Ha

    1998-12-01

    Although the introduction of computerized working environment to the nuclear facilities, the study on the human factors impacts of computers and automation has not been enough like the other industries. It is necessary to prepare the way to cope with the negative aspects in spite of many positive aspects of computerization in nuclear. This study is an empirical study including the survey of the human factor concerning, especially to the cognitive response of operators' and the experiments on the error proneness. At first, we survey the design and its changes of operator interface and interaction in nuclear power plants, and conclude five human factor issues. We discuss situation awareness issues as one of the major human factor concerning, and the assessment method. Secondly, a questionnaire and interviews survey to the operator's response characteristics are performed for possible criterion measures tot he in-depth study on the cognitive characteristics. Finally, several experiments are conducted to test the error proneness. The issues and findings of this study could be utilized to any further study on the cognitive characteristic of operators to the computerized work environment

  20. Computerized radionuclidic analysis in production facilities

    International Nuclear Information System (INIS)

    Gibbs, A.

    1978-03-01

    The Savannah River Plant Laboratories Department has been using a dual computer system to control all radionuclidic pulse height analyses since 1971. This computerized system analyzes 7000 to 8000 samples per month and has allowed the counting room staff to be reduced from three persons to one person. More reliable process information is being returned to the production facilities and for environmental evaluations and being returned faster, even though the sample load has more than tripled. This information is now more easily retrievable for other evaluations. The computer is also used for mass spectrometer data reduction and for quality control data analysis. The basic system is being expanded by interfacing microcomputers which provide data input from all of the laboratory modules for quality assurance programs

  1. Research on accounting transition from computerization to informationization

    Directory of Open Access Journals (Sweden)

    Shu Chen

    2017-11-01

    Full Text Available The application for computer technology, digitalization technology and network technology in the accounting field has promoted the development of accounting informationization. Accounting informationization is a product integrated with traditional accounting theory and modern information technology, which is an inevitable trend of continuous development of modern accounting. This paper discusses the basic concepts and characteristics of accounting computerization and informationization based on the normative research method and literature data method, analyzes the feasibility of accounting transition from computerization to informationization, and finally puts forward the specific approaches and ultimate goals of accounting transition from computerization to informationization.

  2. Development and prospects of X-ray computerized tomography. I

    International Nuclear Information System (INIS)

    Dobes, V.

    1985-01-01

    The history and developmental trends are described of X-ray computerized tomography (CT) as are its applications in clinical practise. Suitable criteria and economic aspects are proposed for the choice of CT systems. The types are listed and described of X-ray CT systems, including brain, whole-body, mobile and special systems. A table is given showing available specifications (types of detectors, X-ray source, resolution, configuration, scan angles, scan fields, image reconstruction, etc.) for machines by different companies. (M.D.)

  3. Cranial computerized tomography in children suffering from acute leukemia

    International Nuclear Information System (INIS)

    Metz, O.

    1981-01-01

    Cranial computerized (axial) tomography permits a more complete neurologic supervision of children with acute leukemia and a better knowledge of the frequency and varieties of cerebral complications in leukemia. Endocranial complications in acute leukemia are essentially infiltrative, hemorrhagic, infectious or iatrogenic. Cranial computerized tomography can demonstrate cerebral changes in meningeal leukemia, hemorrhages, calcifications, brain atrophy or leukencephalopathy. The preliminary results of cranial computerized tomography in childhood leukemia suggest that the iatrogenic main lesion of the brain due to combined radiation-chemotherapy is atrophy whereas that of the intrathecal cytostatic therapy is demyelination. Accurate diagnostics and control of possible cerebral complications in therapy of leukemia is essentially for appropriate therapeutic management. For that cranial computerized tomography is the best method to a effective supervision of the brain. (author)

  4. Use of computerized data acquisition system to auralize NDE data for improved inspection capability

    International Nuclear Information System (INIS)

    Light, Glenn M.; Holt, Amos E.; Polk, Kent D.; Clayton, William T.

    2004-01-01

    Southwest Research Institute has developed computer-aided technology for converting electronic signals generated by conventional nondestructive evaluation (NDE) equipment (i.e., ultrasonic, eddy current, and acoustic emission) into audible information so that the inspector can make use of both the conventional NDE signals (which are often confusing) and the audible information to make a flaw/nonflaw decision. One objective of this work was to develop a computerized data acquisition system that could collect ultrasonic data, perform time dilation of the ultrasonic data, and help develop algorithms. The aural technology has been applied to composite impact damage, composite delamination detection, and corrosion detection. In addition, the aural technology was used to detect and discriminate intergranular stress corrosion cracking. Examples of application of aural NDE technology are described. (author)

  5. A computerized assessment and response system for radiological emergency at Diablo Canyon Nuclear Power Plant

    International Nuclear Information System (INIS)

    Shih, C.C.; Thuillier, R.H.

    1984-01-01

    The U.S. Nuclear Regulatory Commission requires that nuclear power plants provide for rapid assessment and response in the event of a radiological emergency. At the Diablo Canyon Nuclear Power Plant, Pacific Gas and Electric Company uses a system of linked central minicomputer, satellite desktop computers and microprocessors to provide decision makers with timely and pertinent information in emergency situations. The system provides for data acquisition and microprocessing at meteorological and radiological monitoring sites. Current estimates or projections of offsite dose commitment are made in real-time by a dispersion/dose calculation model. Computerized dissemination of data and calculational results to decision makers at the government and utility levels is also available. The basic system in use is a commercially available Emergency Assessment and Response System (EARS). This generic system has been modified in-house to meet requirements specific to emergency situations at the plant. Distinctive features of the modification program includes: a highly professional man-machine interaction; consideration of site-specific factors; simulation of environmental radiology for development of drill scenarios; and concise, pertinent reports as input to decision making

  6. Resposta cardiovascular ao Stroop: comparação entre teste computadorizado e verbal Respuesta cardiovascular al Stroop: comparación entre test computarizado y verbal Cardiovascular response to Stroop test: comparison between the computerized and verbal tests

    Directory of Open Access Journals (Sweden)

    Daniel Fernandes Barbosa

    2010-04-01

    óricos entre el Stroop 3 y la línea de base, se utilizaron test t para muestras apareadas. Además, a fin evaluar el impacto de las diferencias entre las medidas fisiológicas relativas al Stroop 3 y la línea de base, se estimó la magnitud de los efectos (d'. RESULTADOS: Las dos versiones del instrumento produjeron una elevación significativa en la frecuencia cardiaca (p BACKGROUND: The Stroop test requires the individual to respond to specific elements of a stimulus, whereas inhibiting more automated processes. OBJECTIVE: To compare the cardiovascular reactivity induced by the computerized version of the Stroop word-color test TESTINPACS® with the traditional version based on the reading of printed words. METHODS: The sample of convenience consisted of 20 women (22.4 ± 4.1 years. Analyses of variance with repeated measures were used to compare the main effects between the tests (computerized vs verbal, as well as between phases of the test (baseline, Stroop 1, Stroop 3 on the physiological variables (arterial pressure, respiratory sinus arrhythmia, heart failure and respiratory rate. The t tests for paired samples were used to compare the pressure means between Stroop 3 and baseline. Additionally, the magnitude of the effects (d' was estimated in order to assess the impact of the changes in the physiological measurements between Stroop 3 and the baseline. RESULTS: The two versions of the assessment tool caused significant increase in heart rate (p<0.01 and systolic arterial pressure (p<0.05 when the measurements obtained at the Stroop 3 were compared to that of baseline. However, no significant differences were observed regarding the different versions of the test on the other investigated variables. The d' statistics confirmed the high magnitude of the effects (-1.04 to +1.49 between the measurements from the Stroop 3 and the baseline ones. CONCLUSION: It is concluded that the current computerized version (TESTINPACS TM of the Stroop test constitutes a useful

  7. Repeated use of computerized case simulations in a test format does not present a security risk.

    Science.gov (United States)

    Lynch, T G; Zadalis, R J; Schneider, P D

    1999-03-01

    Computer-based examination formats permit evaluation of patient care strategies in a realistic context. Because such examinations are complex and difficult to develop, the same case simulations must often be used on multiple occasions. To determine if repeated, serial administration of computerized case simulations influences performance, 8 simulations were administered over 2 consecutive years to 252 third-year medical students at the conclusion of 16 surgical clerkship rotations (8 per year). One-way analyses of variance were used to compare scores across rotations during the year and to compare scores between 2 consecutive academic years. Scheffe pairwise comparisons were used to identify trends within each academic year. The data demonstrate an increase in scores across rotations during the year. There is, however, no difference between scores in successive years. The data are consistent with an increase in knowledge during the course of the year, without evidence that test information transfer influences the performance of successive classes.

  8. Influence of step complexity and presentation style on step performance of computerized emergency operating procedures

    Energy Technology Data Exchange (ETDEWEB)

    Xu Song [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Li Zhizhong [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)], E-mail: zzli@tsinghua.edu.cn; Song Fei; Luo Wei; Zhao Qianyi; Salvendy, Gavriel [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)

    2009-02-15

    With the development of information technology, computerized emergency operating procedures (EOPs) are taking the place of paper-based ones. However, ergonomics issues of computerized EOPs have not been studied adequately since the industrial practice is quite limited yet. This study examined the influence of step complexity and presentation style of EOPs on step performance. A simulated computerized EOP system was developed in two presentation styles: Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination. Step complexity was quantified by a complexity measure model based on an entropy concept. Forty subjects participated in the experiment of EOP execution using the simulated system. The results of data analysis on the experiment data indicate that step complexity and presentation style could significantly influence step performance (both step error rate and operation time). Regression models were also developed. The regression analysis results imply that operation time of a step could be well predicted by step complexity while step error rate could only partly predicted by it. The result of a questionnaire investigation implies that step error rate was influenced not only by the operation task itself but also by other human factors. These findings may be useful for the design and assessment of computerized EOPs.

  9. Finite impulse testing (FIT) system for Emergency Cooling System (ECS) in Dhruva

    International Nuclear Information System (INIS)

    Punekar, Parag; Ramkumar, N.; Kulkarni, U.S.; Darbhea, M.D.; Bharadhwaj, G; Jangra, L.R.; Geetha, Patil; Das, Shantanu; Sonnis, S.T.; Trevedi, P.; Patil, M.B.; Biswas, B.B.

    2006-01-01

    Finite Impulse Testing (FIT) system for Emergency Cooling System (ECS) is used to check healthiness of ECS logic circuits in an online mode. The ECS is an important safety system that ensures the cooling of reactor core during shutdown state of Main Coolant Pumps (MCPs), and hence FIT-ECS that monitors the health of ECS logic circuits in an online (real time) mode is an important part of it. Based on a Safety Related Unusual Occurrence in ECS system due to the malfunction of its earlier single channel FIT system, the new FIT-ECS system has been designed with new features and is commissioned. The FIT-ECS system feeds the simulated input signals (fine impulses of nominal width 575 μS) to the ECS logic circuits and read the outputs. These output (predicted) signals from ECS logic circuit are processed in the FIT-ECS system and in event of any discrepancy, the FIT-ECS system displays fault signature on local panel, detailed information of the fault on Operator Console (OC), and generates an alarm 'ECS logic Fail' in the control room. FIT-ECS also monitors the inputs and outputs of ECS logic circuit. All the information required is stored as a database that can be subsequently displayed in various formats. ECS system is designated as Category I-A system and is a hardwired system and FIT-ECS monitors the healthiness of the logics of the ECS System is a computerized system. As per IEC 1226, FIT-ECS is categorized as Category I-B system. This paper provides technical information on FIT-ECS system design, its important features, the testing carried on the FIT-ECS system, interconnections of FIT-ECS and ECS and the commissioning experience of FIT-ECS system. (author)

  10. The ECO computerized cognitive battery: collection of normative data using elderly New Zealanders.

    Science.gov (United States)

    Merrick, Paul I; Secker, David I; Fright, Renee; Melding, Pamela

    2004-03-01

    Computerized testing in the elderly has multiple advantages, including increased time-efficiency, a wider range of stimulus options and response forms, and increased psychometric reliability. The French-language ECO (Examen Cognitif par Ordinateur, Ritchie et al., 1993) computerized cognitive battery is investigated in this study. The purpose of the study was to yield normative data for an English-language version of the ECO, test the effects of age and education on test scores, to observe individual subtest sensitivity to cognitive impairment, and to examine participants' receptivity to this form of testing. A sample of 129 community-dwelling elderly with normal cognitive functioning and 56 cognitively impaired older adults living in both independent and supported accommodation were tested using the ECO at either their own residence or an outpatient facility. Standardized scores for three different age bands are given for both impaired and non-impaired groups. Age and education effects varied between subtests. A discriminant analysis of subtest-sensitivity to group prediction is reported using a stepwise regression model. The English version of the ECO appears to be a sensitive and practical cognitive battery that is highly acceptable to older people.

  11. Reducing drug–herb interaction risk with a computerized reminder system

    Directory of Open Access Journals (Sweden)

    Lin SS

    2015-02-01

    Full Text Available Sheng-Shing Lin,1,2 Chiu-Lin Tsai,3 Ching-Yeh Tu,3 Ching-Liang Hsieh2,4,5 1Graduate Institute of Chinese Medicine, College of Chinese Medicine, China Medical University, 2Department of Chinese Medicine, China Medical University Hospital, 3Division of Chinese Medicine, Department of Pharmacy, China Medical University Hospital, 4Graduate Institute of Integrated Medicine, College of Chinese Medicine, China Medical University, 5Research Center for Chinese Medicine and Acupuncture, China Medical University, Taichung, Taiwan Background: Traditional Chinese medicine (TCM and Western medicine are both popular in Taiwan. Approximately 14.1% of Taiwanese residents use Western drugs and Chinese herbs concurrently; therefore, drug–herb interaction is critical to patient safety. This paper presents a new procedure for reducing the risk of drug interactions.Methods: Hospital computer systems are modified to ensure that drug–herb interactions are automatically detected when a TCM practitioner is writing a prescription. A pop-up reminder appears, warning of interactions, and the practitioner may adjust doses, delete herbs, or leave the prescription unchanged. A pharmacist will receive interaction information through the system and provide health education to the patient.Results: During the 2011–2013 study period, 256 patients received 891 herbal prescriptions with potential drug–herb interactions. Three of the 50 patients who concurrently used ginseng and antidiabetic drugs manifested hypoglycemia (fasting blood sugar level ≤70 mg/dL.Conclusion: Drug–herb interactions can cause adverse reactions. A computerized reminder system can enable TCM practitioners to reduce the risk of drug–herb interactions. In addition, health education for patients is crucial in avoiding adverse reaction by the interactions. Keywords: Traditional Chinese medicine, Western medicine, adverse reaction

  12. Development of computerized risk management tool

    International Nuclear Information System (INIS)

    Kil Yoo Kim; Mee Jung Hwang; Seung Cheol Jang; Sang Hoon Han; Tae Woon Kim

    1997-01-01

    The author describes the kinds of efforts for the development of computerized risk management tool; (1) development of a risk monitor, Risk Monster, (2) improvement of McFarm (Missing Cutsets Finding Algorithm for Risk Monitor) and finally (3) development of reliability database management system, KwDBMan. Risk Monster supports for plant operators and maintenance schedulers to monitor plant risk and to avoid high peak risk by rearranging maintenance work schedule. Improved McFarm significantly improved calculation speed of Risk Monster for the cases of supporting system OOS (Out Of Service). KwDBMan manages event data, generic data and CCF (Common Cause Failure) data to support Risk Monster as well as PSA tool, KIRAP (KAERI Integrated Reliability Analysis Package)

  13. Discussion of “Attitude of Physicians Towards Automatic Alerting in Computerized Physician Order Entry Systems”

    DEFF Research Database (Denmark)

    Bates, D. W.; Baysari, M. T.; Dugas, M.

    2013-01-01

    With these comments on the paper “Attitude of Physicians Towards Automatic Alerting in Computerized Physician Order Entry Systems”, written by Martin Jung and coauthors, with Dr. Elske Ammenwerth as senior author, the journal wants to stimulate a broad discussion on computerized physician order...... entry systems. An international group of experts have been invited by the editor of Methods to comment on this paper. Each of the invited commentaries forms one section of this paper....

  14. MMPI-2 and MMPI-A Computerized Interpretation: An Adjunct to Quality Mental Health Service.

    Science.gov (United States)

    Phelps, LeAdelle

    1994-01-01

    Provides reviews of computerized scoring and interpretive systems for the Minnesota Multiphasic Personality Inventory (MMPI-2 and MMPI-A): Caldwell Report, the Psychological Assessment Resources MMPI-2 Interpretive System, and the National Computer Systems Programs. Concludes that when used appropriately, such scoring systems enhance a counselor's…

  15. Computerized videodefecography versus defecography: do we need radiographs?

    Directory of Open Access Journals (Sweden)

    Carlos Walter Sobrado

    Full Text Available CONTEXT AND OBJECTIVE: Defecography has been recognized as a valuable method for evaluating patients with evacuation disorders. It consists of the use of static radiography and fluoroscopy to record different situations within anorectal dynamics. Conventionally, rectal parameters are measured using radiograms. It is rare for fluoroscopy alone to be used. Computer software has been developed with the specific aim of calculating these measurements from digitized videotaped images obtained during fluoroscopy, without the need for radiographic film, thereby developing a computerized videodefecography method. The objective was thus to compare measurements obtained via computerized videodefecography with conventional measurements and to discuss the advantages of the new method. DESIGN AND SETTING: Prospective study at the radiology service of Hospital das Clínicas, Universidade de São Paulo. METHOD: Ten consecutive normal subjects underwent videodefecography. The anorectal angle, anorectal junction, puborectalis muscle length, anal canal length and degree of anal relaxation were obtained via the conventional method (using radiography film and via computerized videodefecography using the ANGDIST software. Measurement and analysis of these parameters was performed by two independent physicians. RESULTS: Statistical analysis confirmed that the measurements obtained through direct radiography film assessment and using digital image analysis (computerized videodefecography were equivalent. CONCLUSIONS: Computerized videodefecography is equivalent to the traditional defecography examination. It has the advantage of offering reduced radiation exposure through saving on the use of radiography.

  16. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  17. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  18. Computerized tomography in evaluation of the pulmonary hilum

    International Nuclear Information System (INIS)

    Secaf, M.; Ferreira, J.L.N.; Secaf, E.

    1987-01-01

    The use of computerized tomography as a method for evaluating the pulmonary hilum and its application in the diagnosis of endobronchial lesions, hilar masss, contiguous involvement of the mediastinum by hilar mass, and vascular hilar lesions are discussed. A comparative evaluation between conventional tomograms and computerized tomography is presented. (M.A.C.) [pt

  19. Computerized measures of finger tapping: effects of hand dominance, age, and sex.

    Science.gov (United States)

    Hubel, Kerry A; Reed, Bruce; Yund, E William; Herron, Timothy J; Woods, David L

    2013-06-01

    Computerized measures of digit tapping rate were obtained over 3 successive, 10-sec. periods in the right and left index fingers, from a community sample of 1,519 participants (ages 18 to 65 years; 607 men, 912 women). Differences between the dominant and non-dominant hands were found for tapping rate, movement initiation, and button down times, and the decline in tapping rate over the successive, 10-sec. periods. Declines were found in tapping rate in older participants in association with increased intertap variability. Men had higher tapping rates than women in all age ranges. The computerized finger tapping test is an efficient and precise measure of tapping speed and kinetics of potential utility in research and clinical studies of motor performance.

  20. Diagnostic Yield of Transbronchial Biopsy in Comparison to High Resolution Computerized Tomography in Sarcoidosis Cases

    Science.gov (United States)

    Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan

    2018-04-25

    This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License

  1. Reduction in unnecessary red blood cell folate testing by restricting computerized physician order entry in the electronic health record.

    Science.gov (United States)

    MacMillan, Thomas E; Gudgeon, Patrick; Yip, Paul M; Cavalcanti, Rodrigo B

    2018-05-02

    Red blood cell folate is a laboratory test with limited clinical utility. Previous attempts to reduce physician ordering of unnecessary laboratory tests, including folate, have resulted in only modest success. The objective of this study was to assess the effectiveness and impacts of restricting red blood cell folate ordering in the electronic health record. This was a retrospective observational study from January 2010 to December 2016 at a large academic healthcare network in Toronto, Canada. All inpatients and outpatients who underwent at least 1 red blood cell folate or vitamin B12 test during the study period were included. Red blood cell folate ordering was restricted to clincians in gastroenterology and hematology and was removed from other physicians' computerized order entry screen in the electronic health record in June 2013. Red blood cell folate testing decreased by 94.4% during the study, from a mean of 493.0 (SD 48.0) tests/month before intervention to 27.6 (SD 10.3) tests/month after intervention (P<.001). Restricting red blood cell folate ordering in the electronic health record resulted in a large and sustained reduction in red blood cell folate testing. Significant cost savings estimated at over a quarter-million dollars (CAD) over three years were achieved. There was no significant clinical impact of the intervention on the diagnosis of folate deficiency. Copyright © 2018. Published by Elsevier Inc.

  2. Computerized portable microwave hyperthermia quality assurance kit

    International Nuclear Information System (INIS)

    Cheung, A.Y.; Neyzari, A.

    1985-01-01

    A computerized quality assurance kit to provide precise measurement and calibration of microwave power and temperature, as well as capabilities to map SAR (Specific absorption rate) distribution in phantoms; and survey of hazardous microwave leakage has been designed. The kit is also capable of performing corelation studies on the relationship between SAR and net microwave power delivered at various anatomical sites. The kit consists of a portable microcomputer, a time-multiplexed A/D converter, a 4-channel dual directional microwave power monitor, a 4-channel thin-wire thermocouple thermometry system, an electronic thermal calibrator, a microwave leakage hazard survey meter, and a dynamic phantom tank for dosimetric analysis. Comparative performance studies were made against NBS-traceable power and temperature standards, non-perturbing optical temperature sensors, and established power and temperature measurement devices. The test results indicate that this instrument is providing its user with measurement accuracy of 0.1 0 C in temperature, 10% accuracy in power. The thin-wire thermocouple, with computer assisted error compensation, performs equally well in a strong microwave field in comparison with non-perturbing optical temperature sensors

  3. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  4. COMPUTERIZED HEAT-TREATMENT IN A ZIMBABWEAN FACTORY

    Directory of Open Access Journals (Sweden)

    M. Collier

    2012-01-01

    Full Text Available In the context of Zimbabwe's current economic problems, parts of the manufacturing industry are turning their attention to the possibility of utilising local design talent in upgrading their manufacturing plants. This paper describes a project undertaken by the National University of Science and Technology to convert the heat-treatment process in a major manufacturing plant from semi -manual to a computerized one. The system comprises microcontroller connection to the furnaces and sensors, and communicates with a central computer on which software for a windowed user-interface is hosted. Experimental results for the system are presented, and a strategy for other companies in the same predicament is proposed.

  5. Computerization of operation and maintenance for nuclear power plants

    International Nuclear Information System (INIS)

    1995-07-01

    This report provides a resource for computerization of activities in plant operation and maintenance. Experience gained from design and implementation of various computer systems around the world is described. The material may be useful as a guide to modification and upgrading of existing plants as well as design and engineering of new plants. It should be particularly of interest to managers and engineers who are engaged in planning, bidding, specifying or designing computer systems for operation and maintenance applications. Refs, figs and tabs

  6. Computerization of operation and maintenance for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    This report provides a resource for computerization of activities in plant operation and maintenance. Experience gained from design and implementation of various computer systems around the world is described. The material may be useful as a guide to modification and upgrading of existing plants as well as design and engineering of new plants. It should be particularly of interest to managers and engineers who are engaged in planning, bidding, specifying or designing computer systems for operation and maintenance applications. Refs, figs and tabs.

  7. Tight integration of computerized procedures with plant information at the South Texas Project

    International Nuclear Information System (INIS)

    Brtis, J.S.; Green, T.

    1996-01-01

    This paper describes a unique undertaking that is underway at Houston Lighting and Power's South Texas Project (STP). The paper presents an information upgrade project that uses expert system technologies to computerize design change procedures and to tightly integrate the resulting on-line, interactive procedures with the on-line information that design change activities use and generate. This effort will show how procedure computerization can leverage the large investments in plant data. The expected benefits include reduced costs and improved quality of design change work, plus a significant reduction in the burden of configuration management that comes from design changes. Both process computerization and the integration of process with data are being implemented at STP. This work is part of a major migration of information from a mainframe to a LAN platform. This paper will be of greatest interest to those involved in: (1) configuration management, (2) coordinating information to support design change procedures, (3) plant information management, and (4) business process reengineering

  8. A Development Method of Mobile Computerized Procedure System for the Cooperation among Field Workers and Main Control Room Operators in Korean Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Sun Jin; Seong, No Kyu; Jung, Yeon Sub

    2014-01-01

    Human errors can occur during the test and maintenance of steam generator, safety injection system and other various systems and devices in nuclear power plants (NPPs). Most of human errors can be improved by the human error prevention techniques such as self-check, peer-check, concurrent verification and etc. Another important technique is to share work information among main control room (MCR) operators and field workers. Various field service automation tools have been developed with recent information technology in many countries. APR1400 computerized procedure system (CPS) has been developed for the MCR operators of Shin-Kori 3 and 4 units. Especially, the concurrent verification support design is applied in the construction project of Shin-Hanul 1 and 2 CPS. It is expected that the proposed mobile CPS can enhance the reduction of human errors by supporting human error prevention techniques and information sharing. This paper describes the technical issues of the mobile CPS (mobile CPS) in the initial development stage. Based on the design of APR1400, CRI CPS has been developed and operated for SKN 3 and 4 HFE V and V and license test for the MCR operating staff. Therefore the mobile CPS will be developed by upgrading the CRI CPS with improved features

  9. A Development Method of Mobile Computerized Procedure System for the Cooperation among Field Workers and Main Control Room Operators in Korean Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sun Jin; Seong, No Kyu; Jung, Yeon Sub [KHNP ,Daejeon (Korea, Republic of)

    2014-08-15

    Human errors can occur during the test and maintenance of steam generator, safety injection system and other various systems and devices in nuclear power plants (NPPs). Most of human errors can be improved by the human error prevention techniques such as self-check, peer-check, concurrent verification and etc. Another important technique is to share work information among main control room (MCR) operators and field workers. Various field service automation tools have been developed with recent information technology in many countries. APR1400 computerized procedure system (CPS) has been developed for the MCR operators of Shin-Kori 3 and 4 units. Especially, the concurrent verification support design is applied in the construction project of Shin-Hanul 1 and 2 CPS. It is expected that the proposed mobile CPS can enhance the reduction of human errors by supporting human error prevention techniques and information sharing. This paper describes the technical issues of the mobile CPS (mobile CPS) in the initial development stage. Based on the design of APR1400, CRI CPS has been developed and operated for SKN 3 and 4 HFE V and V and license test for the MCR operating staff. Therefore the mobile CPS will be developed by upgrading the CRI CPS with improved features.

  10. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Remacle, J.; Quoidbach, G.

    1993-01-01

    The concept of 'computerized management' of plant intervention tasks was developed by TRACTEBEL in 1983 for the Belgian power plants of ELECTRABEL. The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant in planning, organizing, and carrying out any (preventive or corrective) maintenance task. It consists of a group of interconnected functional modules acting on a unique and homogeneous data base. A short description of 3 modules is given, i.e., the 'User' Module, the 'Equipment' Module and the 'Periodic Procedure' Module. (Z.S.)

  11. A computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. II

    International Nuclear Information System (INIS)

    Wouters, F.R.; Frithiof, L.; Soeder, P.Oe.; Hellden, L.; Lavstedt, S.; Salonen, L.

    1988-01-01

    The study was aimed at analyzing intra- and inter-examiner variations in computerized measurement and in non-measurability of alveolar bone level in a cross-sectional, epidemiologic material. At each interproximal tooth surface, alveolar bone height in percentage of root length (B/R) and tooth length (B/T) were determined twice by one examiner and once by a second examiner from X5-magnified periapical radiographs. The overall intra- and inter-examiner variations in measurement were 2.85% and 3.84% of root length and 1.97% and 2.82% of tooth length, respectively. The varations were different for different tooth groups and for different degrees of severity of marginal periodontitis. The overall proportions on non-measurable tooth surfaces varied with examiner from 32% to 39% and from 43% to 48% of the available interproximal tooth surfaces for B/R and B/T, respectively. With regard to the level of reliability, the computerized method reported is appropriate to cross-sectional, epidemiologic investigations from radiographs

  12. Computerized tomography of the vertebral column following traumatic lesion

    International Nuclear Information System (INIS)

    Taenzer, B.; Gmelin, E.; Burmester, E.; Babaian, E.; Weiss, H.D.; Hohlbach, G.

    1984-01-01

    In 58 patients with lesions of the vertebral column in the thoracal and lumbar section established by conventional X-ray, the informative power of computerized tomography was tested. Axial projection with the superimposition-free presentation of bone and soft-tissue structures in the motional segment clears up the diagnostically decisive question of the extent of the lesion and form of fracture, and thus provides information on the stability or instability of the fracture relevant for the therapeutic action taken. All patients had compression fractures of vertebrae, with a fragment of the front edge broken away in 50 cases and one of the back edge broken away in 17 cases. In 30 cases the intervertebral disks were damaged. 43 fractures were stable, 25 were unstable. The instability of 13 fractures was only recognized by CT. In essence, the diagnostic action to be taken begins with a grand-survey X-ray in two planes as a screening, with computerized tomography following in the positive case. Conventional tomograms are not necessary. (BWU) [de

  13. Computerized heat balance models to predict performance of operating nuclear power plants

    International Nuclear Information System (INIS)

    Breeding, C.L.; Carter, J.C.; Schaefer, R.C.

    1983-01-01

    The use of computerized heat balance models has greatly enhanced the decision making ability of TVA's Division of Nuclear Power. These models are utilized to predict the effects of various operating modes and to analyze changes in plant performance resulting from turbine cycle equipment modifications with greater speed and accuracy than was possible before. Computer models have been successfully used to optimize plant output by predicting the effects of abnormal condenser circulating water conditions. They were utilized to predict the degradation in performance resulting from installation of a baffle plate assembly to replace damaged low-pressure blading, thereby providing timely information allowing an optimal economic judgement as to when to replace the blading. Future use will be for routine performance test analysis. This paper presents the benefits of utility use of computerized heat balance models

  14. Computerized Attendance Accounting and Emergency Assistance Communications: Viable Tools in Secondary School Administration

    Science.gov (United States)

    Roberts, Vasel W.

    1971-01-01

    In the late 1968, the Space Technology Application Office at the Jet Propulsion Laboratory (JPL) initiated a pilot study to determine whether technological aids could be developed that would help secondary school administrators cope with the volatile and chaotic situations that often accompany student activism, disorders, and riots. The study was conducted in cooperation with the Sacramento City Unified School District (SCUSD) and at the John F. Kennedy Senior High School (JFK) in Sacramento, California. The problems at JFK and in the SCUSD were identified and described to the JPL team by members of the Kennedy staff and personnel at various levels and departments within the school district. The JPL team of engineers restricted their scope to problems that appeared solvable, or at least partially solvable, through the use of technological systems. Thus far, two hardware systems have been developed for use in the school. The first, a personal emergency assistance communication system, has already been tested operationally at JFK and has met the objectives established for it. The second technological aid developed was a computerized attendance accounting system. This system has been fabricated, tested, and installed at JFK. Full-scale operational testing began in April 1971. While studies and hardware tests were in progress at JFK, contacts were made with several other schools in order that, insofar as practicable, hardware designs could allow for possible adaptation to schools other than JFK.

  15. [Is the ICU staff satisfied with the computerized physician order entry? A cross-sectional survey study].

    Science.gov (United States)

    Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto

    2014-01-01

    To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, phealthcare workers were satisfied, albeit not entirely, with the computerized physician order entry. The overall users' satisfaction with computerized physician order entry was lower among physicians compared to other healthcare professionals. The factors associated with satisfaction included the belief that digitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame.

  16. Use of the Dynamic Visual Acuity Test as a screener for community-dwelling older adults who fall.

    Science.gov (United States)

    Honaker, Julie A; Shepard, Neil T

    2011-01-01

    Adequate function of the peripheral vestibular system, specifically the vestibulo-ocular reflex (VOR; a network of neural connections between the peripheral vestibular system and the extraocular muscles) is essential for maintaining stable vision during head movements. Decreased visual acuity resulting from an impaired peripheral vestibular system may impede balance and postural control and place an individual at risk of falling. Therefore, sensitive measures of the vestibular system are warranted to screen for the tendency to fall, alerting clinicians to recommend further risk of falling assessment and referral to a falling risk reduction program. Dynamic Visual Acuity (DVA) testing is a computerized VOR assessment method to evaluate the peripheral vestibular system during head movements; reduced visual acuity as documented with DVA testing may be sensitive to screen for falling risk. This study examined the sensitivity and specificity of the computerized DVA test with yaw plane head movements for identifying community-dwelling adults (58-78 years) who are prone to falling. A total of 16 older adults with a history of two or more unexplained falls in the previous twelve months and 16 age and gender matched controls without a history of falls in the previous twelve months participated. Computerized DVA with horizontal head movements at a fixed velocity of 120 deg/sec was measured and compared with the Dynamic Gait Index (DGI) a gold standard gait assessment measurement for identifying falling risk. Receiver operating characteristics (ROC) curve analysis and area under the ROC curve (AUC) were used to assess the sensitivity and specificity of the computerized DVA as a screening measure for falling risk as determined by the DGI. Results suggested a link between computerized DVA and the propensity to fall; DVA in the yaw plane was found to be a sensitive (92%) and accurate screening measure when using a cutoff logMAR value of >0.25.

  17. Study of the Switching Errors in an RSFQ Switch by Using a Computerized Test Setup

    International Nuclear Information System (INIS)

    Kim, Se Hoon; Baek, Seung Hun; Yang, Jung Kuk; Kim, Jun Ho; Kang, Joon Hee

    2005-01-01

    The problem of fluctuation-induced digital errors in a rapid single flux quantum (RSFQ) circuit has been a very important issue. In this work, we calculated the bit error rate of an RSFQ switch used in superconductive arithmetic logic unit (ALU). RSFQ switch should have a very low error rate in the optimal bias. Theoretical estimates of the RSFQ error rate are on the order of 10 -50 per bit operation. In this experiment, we prepared two identical circuits placed in parallel. Each circuit was composed of 10 Josephson transmission lines (JTLs) connected in series with an RSFQ switch placed in the middle of the 10 JTLs. We used a splitter to feed the same input signal to both circuits. The outputs of the two circuits were compared with an RSFQ exclusive OR (XOR) to measure the bit error rate of the RSFQ switch. By using a computerized bit-error-rate test setup, we measured the bit error rate of 2.18 x 10 -12 when the bias to the RSFQ switch was 0.398 mA that was quite off from the optimum bias of 0.6 mA.

  18. Reproducibility of ad libitum energy intake with the use of a computerized vending machine system123

    Science.gov (United States)

    Votruba, Susanne B; Franks, Paul W; Krakoff, Jonathan; Salbe, Arline D

    2010-01-01

    Background: Accurate assessment of energy intake is difficult but critical for the evaluation of eating behavior and intervention effects. Consequently, methods to assess ad libitum energy intake under controlled conditions have been developed. Objective: Our objective was to evaluate the reproducibility of ad libitum energy intake with the use of a computerized vending machine system. Design: Twelve individuals (mean ± SD: 36 ± 8 y old; 41 ± 8% body fat) consumed a weight-maintaining diet for 3 d; subsequently, they self-selected all food with the use of a computerized vending machine system for an additional 3 d. Mean daily energy intake was calculated from the actual weight of foods consumed and expressed as a percentage of weight-maintenance energy needs (%WMEN). Subjects repeated the study multiple times during 2 y. The within-person reproducibility of energy intake was determined through the calculation of the intraclass correlation coefficients (ICCs) between visits. Results: Daily energy intake for all subjects was 5020 ± 1753 kcal during visit 1 and 4855 ± 1615 kcal during visit 2. There were no significant associations between energy intake and body weight, body mass index, or percentage body fat while subjects used the vending machines, which indicates that intake was not driven by body size or need. Despite overconsumption (%WMEN = 181 ± 57%), the reproducibility of intake between visits, whether expressed as daily energy intake (ICC = 0.90), %WMEN (ICC = 0.86), weight of food consumed (ICC = 0.87), or fat intake (g/d; ICC = 0.87), was highly significant (P < 0.0001). Conclusion: Although ad libitum energy intake exceeded %WMEN, the within-person reliability of this intake across multiple visits was high, which makes this a reproducible method for the measurement of ad libitum intake in subjects who reside in a research unit. This trial was registered at clinicaltrials.gov as NCT00342732. PMID:19923376

  19. The United States Department of Energy (DOE) Computerized Accident/Incident Reporting System (CAIRS)

    International Nuclear Information System (INIS)

    Briscoe, G.J.

    1993-01-01

    The Department of Energy's (DOE) Computerized Accident/Incident Reporting System (CAIRS) is a comprehensive data base containing more than 50,000 investigation reports of injury/illness, property damage and vehicle accident cases representing safety data from 1975 to the present for more than 150 DOE contractor organizations. A special feature is that the text of each accident report is translated using a controlled dictionary and rigid sentence structure called Factor Relationship and Sequence of Events (FRASE) that enhances the ability to retrieve specific types of information and to perform detailed analyses. DOE summary and individual contractor reports are prepared quarterly and annually. In addition, ''Safety Performance Profile'' reports for individual organizations are prepared to provide advance information to appraisal teams, and special topical reports are prepared for areas of concern such as an increase in the number of security injuries or environmental releases. The data base is open to all DOE and Contractor registered users with no access restrictions other than that required by the Privacy Act

  20. Analysis of concrete material through gamma ray computerized tomography

    International Nuclear Information System (INIS)

    Oliveira Junior, J.M. de

    2004-01-01

    Computerized Tomography (CT) refers to the cross sectional imaging of an object from both transmission or reflection data collected by illuminating the object from many different directions. The most important contribution of CT is to greatly improve abilities to distinguish regions with different gamma ray transmittance and to separate over-lying structures. The mathematical problem of the CT imaging is that of estimating an image from its projections. These projections can represent, for example, the linear attenuation coefficient of γ-rays along the path of the ray. In this work we will present some new results obtained by using tomographic techniques to analyze column samples of concrete to check the distribution of various materials and structural problems. These concrete samples were made using different proportions of stone, sand and cement. Another set of samples with different proportions of sand and cement were also used to verify the outcome from the CT analysis and the differences between them. Those samples were prepared at the Material Laboratory of Faculdade de Engenharia de Sorocaba, following the same procedures used in real case of concrete tests. The projections used in this work was obtained by Mini Computerized Tomograph of Uniso (MTCU), located at the Experimental Nuclear Physics Laboratory at University of Sorocaba. This tomograph operates with a gamma ray source of 241 Am (photons of 60 keV and 100 mCi of intensity) and a NaI(Tl) solid state detector. The system features translation and rotation scanning modes, a 100 mm effective field of view, and 1 mm spatial resolution. The image reconstruction problem is solved using Discrete Filtered Backprojection (FBP). (author)

  1. Default settings of computerized physician order entry system order sets drive ordering habits.

    Science.gov (United States)

    Olson, Jordan; Hollenbeak, Christopher; Donaldson, Keri; Abendroth, Thomas; Castellani, William

    2015-01-01

    Computerized physician order entry (CPOE) systems are quickly becoming ubiquitous, and groups of orders ("order sets") to allow for easy order input are a common feature. This provides a streamlined mechanism to view, modify, and place groups of related orders. This often serves as an electronic equivalent of a specialty requisition. A characteristic, of these order sets is that specific orders can be predetermined to be "preselected" or "defaulted-on" whenever the order set is used while others are "optional" or "defaulted-off" (though there is typically the option is to "deselect" defaulted-on tests in a given situation). While it seems intuitive that the defaults in an order set are often accepted, additional study is required to understand the impact of these "default" settings in an order set on ordering habits. This study set out to quantify the effect of changing the default settings of an order set. For quality improvement purposes, order sets dealing with transfusions were recently reviewed and modified to improve monitoring of outcome. Initially, the order for posttransfusion hematocrits and platelet count had the default setting changed from "optional" to "preselected." The default settings for platelet count was later changed back to "optional," allowing for a natural experiment to study the effect of the default selections of an order set on clinician ordering habits. Posttransfusion hematocrit values were ordered for 8.3% of red cell transfusions when the default order set selection was "off" and for 57.4% of transfusions when the default selection was "preselected" (P default order set selection was "optional," increased to 59.4% when the default was changed to "preselected" (P default selection was returned to "optional." The posttransfusion platelet count rates during the two "optional" periods: 7.0% versus 7.5% - were not statistically different (P = 0.620). Default settings in CPOE order sets can significantly influence physician selection of

  2. Effect of gender on computerized electrocardiogram measurements in college athletes.

    Science.gov (United States)

    Mandic, Sandra; Fonda, Holly; Dewey, Frederick; Le, Vy-van; Stein, Ricardo; Wheeler, Matt; Ashley, Euan A; Myers, Jonathan; Froelicher, Victor F

    2010-06-01

    Broad criteria for classifying an electrocardiogram (ECG) as abnormal and requiring additional testing prior to participating in competitive athletics have been recommended for the preparticipation examination (PPE) of athletes. Because these criteria have not considered gender differences, we examined the effect of gender on the computerized ECG measurements obtained on Stanford student athletes. Currently available computer programs require a basis for "normal" in athletes of both genders to provide reliable interpretation. During the 2007 PPE, computerized ECGs were recorded and analyzed on 658 athletes (54% male; mean age, 19 +/- 1 years) representing 22 sports. Electrocardiogram measurements included intervals and durations in all 12 leads to calculate 12-lead voltage sums, QRS amplitude and QRS area, spatial vector length (SVL), and the sum of the R wave in V5 and S wave in V2 (RSsum). By computer analysis, male athletes had significantly greater QRS duration, PR interval, Q-wave duration, J-point amplitude, and T-wave amplitude, and shorter QTc interval compared with female athletes (all P < 0.05). All ECG indicators of left ventricular electrical activity were significantly greater in males. Although gender was consistently associated with indices of atrial and ventricular electrical activity in multivariable analysis, ECG measurements correlated poorly with body dimensions. Significant gender differences exist in ECG measurements of college athletes that are not explained by differences in body size. Our tables of "normal" computerized gender-specific measurements can facilitate the development of automated ECG interpretation for screening young athletes.

  3. Computerized measures of finger tapping: reliability, malingering and traumatic brain injury.

    Science.gov (United States)

    Hubel, Kerry A; Yund, E William; Herron, Timothy J; Woods, David L

    2013-01-01

    We analyzed computerized finger tapping metrics in four experiments. Experiment 1 showed tapping-rate differences associated with hand dominance, digits, sex, and fatigue that replicated those seen in a previous, large-scale community sample. Experiment 2 revealed test-retest correlations (r = .91) that exceeded those reported in previous tapping studies. Experiment 3 investigated subjects simulating symptoms of traumatic brain injury (TBI); 62% of malingering subjects produced abnormally slow tapping rates. A tapping-rate malingering index, based on rate-independent tapping patterns, provided confirmatory evidence of malingering in 48% of the subjects with abnormal tapping rates. Experiment 4 compared tapping in 24 patients with mild TBI (mTBI) and a matched control group; mTBI patients showed slowed tapping without evidence of malingering. Computerized finger tapping measures are reliable measures of motor speed, useful in detecting subjects performing with suboptimal effort, and are sensitive to motor abnormalities following mTBI.

  4. Computerized bioterrorism education and training for nurses on bioterrorism attack agents.

    Science.gov (United States)

    Nyamathi, Adeline M; Casillas, Adrian; King, Major L; Gresham, Louise; Pierce, Elaine; Farb, Daniel; Wiechmann, Carrie; Weichmann, Carrie

    2010-08-01

    Biological agents have the ability to cause large-scale mass casualties. For this reason, their likely use in future terrorist attacks is a concern for national security. Recent studies show that nurses are ill prepared to deal with agents used in biological warfare. Achieving a goal for bioterrorism preparedness is directly linked to comprehensive education and training that enables first-line responders such as nurses to diagnose infectious agents rapidly. The study evaluated participants' responses to biological agents using a computerized bioterrorism education and training program versus a standard bioterrorism education and training program. Both programs improved participants' ability to complete and solve case studies involving the identification of specific biological agents. Participants in the computerized bioterrorism education and training program were more likely to solve the cases critically without reliance on expert consultants. However, participants in the standard bioterrorism education and training program reduced the use of unnecessary diagnostic tests.

  5. Assessing mental workload and situation awareness in the evaluation of computerized procedures in the main control room

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chih-Wei, E-mail: yangcw@iner.gov.tw [Institute of Nuclear Energy Research, 1000, Wenhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Yang, Li-Chen; Cheng, Tsung-Chieh [Institute of Nuclear Energy Research, 1000, Wenhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Jou, Yung-Tsan; Chiou, Shian-Wei [Department of Industrial Engineering, Chung-Yuan Christian University, 200, Chung Pei Rd., Chung-Li 32023, Taiwan (China)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer This study investigates procedure types' effects on operators' performance. Black-Right-Pointing-Pointer The computer-based procedure is suggested to be implemented in the main control room. Black-Right-Pointing-Pointer The computer-based procedure brings lowest mental workload. Black-Right-Pointing-Pointer And it also generates fewer error of omission, and the highest situation awareness. Black-Right-Pointing-Pointer The shift supervisor has the highest workload and the lowest situation awareness. - Abstract: Computerized procedure (CP) system has been developed in nuclear power plant (NPP) instrumentation and control (I and C) system. The system may include normal operating procedures (OPs), abnormal operating procedures (AOPs), alarm response procedures (ARPs), surveillance test procedures (STPs) and/or emergency operating procedures (EOPs). While there are many ways to evaluate computerized procedures design, the user's mental workload and situation awareness (SA) are particularly important considerations in the supervisory control of safety-critical systems. Users' mental workload and situation awareness may be influenced by human factor issues relating to computerized procedures, e.g., level of automation, dealing with (partially) unavailable I and C, switching to back-up system (e.g., paper-based procedures). Some of the positive impacts of CPs on operator performance include the following: tasks can be performed more quickly; overall workload can be reduced; cognitive workload can be minimized; fewer errors may be made in transitioning through or between procedures. However, various challenges have also been identified with CP systems. These should be addressed in the design and implementation of CPs where they are applicable. For example, narrower 'field of view' provided by CP systems than with paper-based procedures could reduce crew communications and crewmember awareness of the

  6. Assessing mental workload and situation awareness in the evaluation of computerized procedures in the main control room

    International Nuclear Information System (INIS)

    Yang, Chih-Wei; Yang, Li-Chen; Cheng, Tsung-Chieh; Jou, Yung-Tsan; Chiou, Shian-Wei

    2012-01-01

    Highlights: ► This study investigates procedure types’ effects on operators’ performance. ► The computer-based procedure is suggested to be implemented in the main control room. ► The computer-based procedure brings lowest mental workload. ► And it also generates fewer error of omission, and the highest situation awareness. ► The shift supervisor has the highest workload and the lowest situation awareness. - Abstract: Computerized procedure (CP) system has been developed in nuclear power plant (NPP) instrumentation and control (I and C) system. The system may include normal operating procedures (OPs), abnormal operating procedures (AOPs), alarm response procedures (ARPs), surveillance test procedures (STPs) and/or emergency operating procedures (EOPs). While there are many ways to evaluate computerized procedures design, the user's mental workload and situation awareness (SA) are particularly important considerations in the supervisory control of safety-critical systems. Users’ mental workload and situation awareness may be influenced by human factor issues relating to computerized procedures, e.g., level of automation, dealing with (partially) unavailable I and C, switching to back-up system (e.g., paper-based procedures). Some of the positive impacts of CPs on operator performance include the following: tasks can be performed more quickly; overall workload can be reduced; cognitive workload can be minimized; fewer errors may be made in transitioning through or between procedures. However, various challenges have also been identified with CP systems. These should be addressed in the design and implementation of CPs where they are applicable. For example, narrower “field of view” provided by CP systems than with paper-based procedures could reduce crew communications and crewmember awareness of the status and progress through the procedure. Based on a human factors experiment in which each participant monitored and controlled multiple simulated

  7. Applying computerized adaptive testing to the Negative Acts Questionnaire-Revised: Rasch analysis of workplace bullying.

    Science.gov (United States)

    Ma, Shu-Ching; Chien, Tsair-Wei; Wang, Hsiu-Hung; Li, Yu-Chi; Yui, Mei-Shu

    2014-02-17

    Workplace bullying is a prevalent problem in contemporary work places that has adverse effects on both the victims of bullying and organizations. With the rapid development of computer technology in recent years, there is an urgent need to prove whether item response theory-based computerized adaptive testing (CAT) can be applied to measure exposure to workplace bullying. The purpose of this study was to evaluate the relative efficiency and measurement precision of a CAT-based test for hospital nurses compared to traditional nonadaptive testing (NAT). Under the preliminary conditions of a single domain derived from the scale, a CAT module bullying scale model with polytomously scored items is provided as an example for evaluation purposes. A total of 300 nurses were recruited and responded to the 22-item Negative Acts Questionnaire-Revised (NAQ-R). All NAT (or CAT-selected) items were calibrated with the Rasch rating scale model and all respondents were randomly selected for a comparison of the advantages of CAT and NAT in efficiency and precision by paired t tests and the area under the receiver operating characteristic curve (AUROC). The NAQ-R is a unidimensional construct that can be applied to measure exposure to workplace bullying through CAT-based administration. Nursing measures derived from both tests (CAT and NAT) were highly correlated (r=.97) and their measurement precisions were not statistically different (P=.49) as expected. CAT required fewer items than NAT (an efficiency gain of 32%), suggesting a reduced burden for respondents. There were significant differences in work tenure between the 2 groups (bullied and nonbullied) at a cutoff point of 6 years at 1 worksite. An AUROC of 0.75 (95% CI 0.68-0.79) with logits greater than -4.2 (or >30 in summation) was defined as being highly likely bullied in a workplace. With CAT-based administration of the NAQ-R for nurses, their burden was substantially reduced without compromising measurement precision.

  8. A Computerized Tablet with Visual Feedback of Hand Position for Functional Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Mahta eKarimpoor

    2015-03-01

    Full Text Available Neuropsychological tests - behavioral tasks that very commonly involve handwriting and drawing - are widely used in the clinic to detect abnormal brain function. Functional magnetic resonance imaging (fMRI may be useful in increasing the specificity of such tests. However, performing complex pen-and-paper tests during fMRI involves engineering challenges. Previously, we developed an fMRI-compatible, computerized tablet system to address this issue. However, the tablet did not include visual feedback of hand position (VFHP, a human factors component that may be important for fMRI of certain patient populations. A real-time system was thus developed to provide VFHP and integrated with the tablet in an augmented reality display. The effectiveness of the system was initially tested in young healthy adults who performed various handwriting tasks in front of a computer display with and without VFHP. Pilot fMRI of writing tasks were performed by two representative individuals with and without VFHP. Quantitative analysis of the behavioral results indicated improved writing performance with VFHP. The pilot fMRI results suggest that writing with VFHP requires less neural resources compared to the without VFHP condition, to maintain similar behavior. Thus, the tablet system with VFHP is recommended for future fMRI studies involving patients with impaired brain function and where ecologically valid behavior is important.

  9. A computerized tablet with visual feedback of hand position for functional magnetic resonance imaging

    Science.gov (United States)

    Karimpoor, Mahta; Tam, Fred; Strother, Stephen C.; Fischer, Corinne E.; Schweizer, Tom A.; Graham, Simon J.

    2015-01-01

    Neuropsychological tests behavioral tasks that very commonly involve handwriting and drawing are widely used in the clinic to detect abnormal brain function. Functional magnetic resonance imaging (fMRI) may be useful in increasing the specificity of such tests. However, performing complex pen-and-paper tests during fMRI involves engineering challenges. Previously, we developed an fMRI-compatible, computerized tablet system to address this issue. However, the tablet did not include visual feedback of hand position (VFHP), a human factors component that may be important for fMRI of certain patient populations. A real-time system was thus developed to provide VFHP and integrated with the tablet in an augmented reality display. The effectiveness of the system was initially tested in young healthy adults who performed various handwriting tasks in front of a computer display with and without VFHP. Pilot fMRI of writing tasks were performed by two representative individuals with and without VFHP. Quantitative analysis of the behavioral results indicated improved writing performance with VFHP. The pilot fMRI results suggest that writing with VFHP requires less neural resources compared to the without VFHP condition, to maintain similar behavior. Thus, the tablet system with VFHP is recommended for future fMRI studies involving patients with impaired brain function and where ecologically valid behavior is important. PMID:25859201

  10. A study on operators' cognitive response characteristics to the computerized working environment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Lee, Jang Soo; Suh, Sang Moon; Lee, Hyun Cheol; Jung, Kwang Tae; Lee, Dhong Ha

    1998-12-01

    Although the introduction of computerized working environment to the nuclear facilities, the study on the human factors impacts of computers and automation has not been enough like the other industries. It is necessary to prepare the way to cope with the negative aspects in spite of many positive aspects of computerization in nuclear. This study is an empirical study including the survey of the human factor concerning, especially to the cognitive response of operators' and the experiments on the error proneness. At first, we survey the design and its changes of operator interface and interaction in nuclear power plants, and conclude five human factor issues. We discuss situation awareness issues as one of the major human factor concerning, and the assessment method. Secondly, a questionnaire and interviews survey to the operator's response characteristics are performed for possible criterion measures to the in-depth study on the cognitive characteristics. Finally, several experiments are conducted to test the error proneness. The issues and findings of this study could be utilized to any further study on the cognitive characteristic of operators to the computerized work environment.

  11. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  12. Results of CT brain examinations in cerebrovascular emergency. [computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pinta, Z; Dolansky, J; Sorfova, J; Jerie, T

    1987-07-01

    Experience is briefly reported with CT (computerized tomography) diagnosis of cerebrovascular emergencies. It is pointed out that the introduction of computerized tomography greatly improved and made more accurate the diagnosis of focal ischemias and revealed significant differences in the foci of ischemia in hypertension patients and atherosclerosis patients without hypertension, and showed a higher incidence of intracerebral and subarachnoidal hemorrhages than previously thought. It is believed that knowledge gained thanks to CT (computerized tomography) will be of benefit to the primary and secondary prevention of cerebrovascular ischemias. (L.O.). 1 fig., 5 refs.

  13. Extrahepatic portal hypertension in childhood. Portographic findings and evaluation of hepatic blood flow by computerized radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-05-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood.

  14. Coupling two iteratives algorithms for density measurements by computerized tomography

    International Nuclear Information System (INIS)

    Silva, L.E.M.C.; Santos, C.A.C.; Borges, J.C.; Frenkel, A.D.B.; Rocha, G.M.

    1986-01-01

    This work develops a study for coupling two iteratives algotithms for density measurements by computerized tomography. Tomographies have been obtained with an automatized prototype, controled by a microcomputer, projected and assembled in the Nuclear Instrumentation Laboratory, at COPPE/UFRJ. Results show a good performance of the tomographic system, and demonstrate the validity of the method of calculus adopted. (Author) [pt

  15. Spiral Computed Tomographic Imaging Related to Computerized Ultrasonographic Images of Carotid Plaque Morphology and Histology

    DEFF Research Database (Denmark)

    Grønholdt, Marie-Louise M.; Wagner, Aase; Wiebe, Britt M.

    2001-01-01

    Echolucency of carotid atherosclerotic plaques, as evaluated by computerized B-mode ultrasonographic images, has been associated with an increased incidence of brain infarcts on cerebral computed tomographic scans. We tested the hypotheses that characterization of carotid plaques on spiral comput...

  16. Computerized tomography in the diagnosis of hyperparathyroidism

    International Nuclear Information System (INIS)

    Sobota, J.; Girl, J.; Sotornik, I.; Kocandrle, V.

    1990-01-01

    Long-term experience in the application of computerized tomography to the diagnosis of hyperparathyroidism is summarized. Based on a large number of examinations (164) of parathyroid glands associated with the possibility of verification and comparison with the results of ultrasonography and other imaging methods, the potential of computerized tomography in the diagnosis of hyperparathyroidism and its advantages and limitations are summarized. It is concluded that owing to its high diagnostic precision, this technique can be regarded reliable in detecting enlarged parathyroid glands. (author). 11 figs., 1 tab., 19 refs

  17. The Role of Item Feedback in Self-Adapted Testing.

    Science.gov (United States)

    Roos, Linda L.; And Others

    1997-01-01

    The importance of item feedback in self-adapted testing was studied by comparing feedback and no feedback conditions for computerized adaptive tests and self-adapted tests taken by 363 college students. Results indicate that item feedback is not necessary to realize score differences between self-adapted and computerized adaptive testing. (SLD)

  18. PADS (Patient Archiving and Documentation System): a computerized patient record with educational aspects.

    Science.gov (United States)

    Hohnloser, J H; Pürner, F

    1992-01-01

    Rapid acquisition and analysis of information in an Intensive Care Unit (ICU) setting is essential, even more so the documentation of the decision making process which has vital consequences for the lives of ICU patients. We describe an Ethernet based local area network (LAN) with clinical workstations (Macintosh fx, ci). Our Patient Archiving and Documentation System (PADS) represents a computerized patient record presently used in a university hospitals' ICU. Taking full advantage of the Macintosh based graphical user interface (GUI) our system enables nurses and doctors to perform the following tasks: admission, medical history taking, physical examination, generation of problem lists and follow up notes, access to laboratory data and reports, semiautomatic generation of a discharge summary including full word processor capabilities. Furthermore, the system offers rapid, consistent and complete automatic encoding of diagnoses following the International Classification of Disease (ICD; WHO, [1]). For educational purposes the user can also view disease entities or complications related to the diagnoses she/he encoded. The system has links to other educational programs such as cardiac auscultation. A MEDLINE literature search through a CD-ROM based system can be performed without exiting the system; also, CD-ROM based medical textbooks can be accessed as well. Commercially available Macintosh programs can be integrated in the system without existing the main program thus enabling users to customize their working environment. Additional options include automatic background monitoring of users learning behavior, analyses and graphical display of numerous epidemiological and health care related problems. Furthermore, we are in the process of integrating sound and digital video in our system. This system represents one in a line of modular departmental models which will eventually be integrated to form a decentralized Hospital Information System (HIS).

  19. Computerized Hammer Sounding Interpretation for Concrete Assessment with Online Machine Learning.

    Science.gov (United States)

    Ye, Jiaxing; Kobayashi, Takumi; Iwata, Masaya; Tsuda, Hiroshi; Murakawa, Masahiro

    2018-03-09

    Developing efficient Artificial Intelligence (AI)-enabled systems to substitute the human role in non-destructive testing is an emerging topic of considerable interest. In this study, we propose a novel hammering response analysis system using online machine learning, which aims at achieving near-human performance in assessment of concrete structures. Current computerized hammer sounding systems commonly employ lab-scale data to validate the models. In practice, however, the response signal patterns can be far more complicated due to varying geometric shapes and materials of structures. To deal with a large variety of unseen data, we propose a sequential treatment for response characterization. More specifically, the proposed system can adaptively update itself to approach human performance in hammering sounding data interpretation. To this end, a two-stage framework has been introduced, including feature extraction and the model updating scheme. Various state-of-the-art online learning algorithms have been reviewed and evaluated for the task. To conduct experimental validation, we collected 10,940 response instances from multiple inspection sites; each sample was annotated by human experts with healthy/defective condition labels. The results demonstrated that the proposed scheme achieved favorable assessment accuracy with high efficiency and low computation load.

  20. Interrater and Intrarater Reliability of the Balance Computerized Adaptive Test in Patients With Stroke.

    Science.gov (United States)

    Chiang, Hsin-Yu; Lu, Wen-Shian; Yu, Wan-Hui; Hsueh, I-Ping; Hsieh, Ching-Lin

    2018-04-11

    To examine the interrater and intrarater reliability of the Balance Computerized Adaptive Test (Balance CAT) in patients with chronic stroke having a wide range of balance functions. Repeated assessments design (1wk apart). Seven teaching hospitals. A pooled sample (N=102) including 2 independent groups of outpatients (n=50 for the interrater reliability study; n=52 for the intrarater reliability study) with chronic stroke. Not applicable. Balance CAT. For the interrater reliability study, the values of intraclass correlation coefficient, minimal detectable change (MDC), and percentage of MDC (MDC%) for the Balance CAT were .84, 1.90, and 31.0%, respectively. For the intrarater reliability study, the values of intraclass correlation coefficient, MDC, and MDC% ranged from .89 to .91, from 1.14 to 1.26, and from 17.1% to 18.6%, respectively. The Balance CAT showed sufficient intrarater reliability in patients with chronic stroke having balance functions ranging from sitting with support to independent walking. Although the Balance CAT may have good interrater reliability, we found substantial random measurement error between different raters. Accordingly, if the Balance CAT is used as an outcome measure in clinical or research settings, same raters are suggested over different time points to ensure reliable assessments. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. Computerization of the standard corsi block-tapping task affects its underlying cognitive concepts: a pilot study.

    Science.gov (United States)

    Claessen, Michiel H G; van der Ham, Ineke J M; van Zandvoort, Martine J E

    2015-01-01

    The tablet computer initiates an important step toward computerized administration of neuropsychological tests. Because of its lack of standardization, the Corsi Block-Tapping Task could benefit from advantages inherent to computerization. This task, which requires reproduction of a sequence of movements by tapping blocks as demonstrated by an examiner, is widely used as a representative of visuospatial attention and working memory. The aim was to validate a computerized version of the Corsi Task (e-Corsi) by comparing recall accuracy to that on the standard task. Forty university students (Mage = 22.9 years, SD = 2.7 years; 20 female) performed the standard Corsi Task and the e-Corsi on an iPad 3. Results showed higher accuracy in forward reproduction on the standard Corsi compared with the e-Corsi, whereas backward performance was comparable. These divergent performance patterns on the 2 versions (small-to-medium effect sizes) are explained as a result of motor priming and interference effects. This finding implies that computerization has serious consequences for the cognitive concepts that the Corsi Task is assumed to assess. Hence, whereas the e-Corsi was shown to be useful with respect to administration and registration, these findings also stress the need for reconsideration of the underlying theoretical concepts of this task.

  2. Implementation of a Computerized Order Entry Tool to Reduce the Inappropriate and Unnecessary Use of Cardiac Stress Tests With Imaging in Hospitalized Patients.

    Science.gov (United States)

    Gertz, Zachary M; O'Donnell, William; Raina, Amresh; Balderston, Jessica R; Litwack, Andrew J; Goldberg, Lee R

    2016-10-15

    The rising use of imaging cardiac stress tests has led to potentially unnecessary testing. Interventions designed to reduce inappropriate stress testing have focused on the ambulatory setting. We developed a computerized order entry tool intended to reduce the use of imaging cardiac stress tests and improve appropriate use in hospitalized patients. The tool was evaluated using preimplementation and postimplementation cohorts at a single urban academic teaching hospital. All hospitalized patients referred for testing were included. The co-primary outcomes were the use of imaging stress tests as a percentage of all stress tests and the percentage of inappropriate tests, compared between the 2 cohorts. There were 478 patients in the precohort and 463 in the postcohort. The indication was chest pain in 66% and preoperative in 18% and was not significantly different between groups. The use of nonimaging stress tests increased from 4% in the pregroup to 15% in the postgroup (p nonimaging stress tests increased from 7% to 25% (p nonimaging cardiac stress tests and reduced the use of imaging tests yet was not able to reduce inappropriate use. Our study highlights the differences in cardiac stress testing between hospitalized and ambulatory patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Quoidbach, G.

    2004-01-01

    The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant or of any other complex industrial facility (chemical industries, refineries, and so on) in planning, organizing, and carrying out any (preventive or corrective) maintenance task. This 'Computerized Management of Plant Intervention Tasks' is organized around a data base of all plant components in the facility that might be subjected to maintenance or tagout. It allows to manage, by means of intelligent and configurable 'mail service', the course of the intervention requests as well as various treatments of those requests, in a safe and efficient way, adapted to each particular organization. The concept of 'Computerized Management' of plant intervention tasks was developed by BELGATOM in 1983 for the Belgian nuclear power plants of ELECTRABEL. A first implementation of this concept was made at that time for the Doel NPP under the name POPIT (Programming Of Plant Intervention Tasks). In 1988, it was decided to proceed to a functional upgrade of the application, using advanced software and hardware techniques and products, and to realize a second implementation in the Tihange NPP under the name ACM (Application Consignation Maintenance). (author)

  4. The computerized management for individual monitoring data in Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Lin Shumou; Yang Xiaochen

    1995-01-01

    The authors report the individual monitoring data management system (IDOSE) at Daya Bay Nuclear Power Station. The components of the individual monitoring system, the design requirements of IDOSE, the characteristics and application of this computerized management system are mainly presented. Its application shows that IDOSE meets the requirements of the concerning occupational standards of the state and matches with the requirements of IAEA/ISOE

  5. A computerized system based on an alternative pulse echo immersion technique for acoustic characterization of non-porous solid tissue mimicking materials

    Science.gov (United States)

    Nazihah Mat Daud, Anis; Jaafar, Rosly; Kadri Ayop, Shahrul; Supar Rohani, Md

    2018-04-01

    This paper discusses the development of a computerized acoustic characterization system of non-porous solid tissue mimicking materials. This system employs an alternative pulse echo immersion technique and consists of a pulser/receiver generator, a transducer used as both a transmitter and a receiver, a digital oscilloscope, and a personal computer with a custom-developed program installed. The program was developed on the LabVIEW 2012 platform and comprises two main components, a user interface and a block diagram. The user interface consists of three panels: a signal acquisition and selection panel, a display panel, and a calculation panel. The block diagram comprises four blocks: a signal acquisition block, a peak signal analysis block, an acoustic properties calculation and display block, and an additional block. Interestingly, the system can be operated in both online and offline modes. For the online mode, the measurements are performed by connecting the system with a Rigol DS2000 Series digital oscilloscope. In contrast, the measurements are carried out by processing the saved data on the computer for the offline mode. The accuracy and consistency of the developed system was validated by a KB-Aerotech Alpha Series transducer with 5 MHz center frequency and a Rigol DS2202 two-channel 200 MHz 2 GSa s-1 digital oscilloscope, based on the measurement of the acoustic properties of three poly(methyl methacrylate) samples immersed in a medium at a temperature of (24.0  ±  0.1) °C. The findings indicated that the accuracy and consistency of the developed system was exceptionally high, within a 1.04% margin of error compared to the reference values. As such, this computerized system can be efficiently used for the acoustic characterization of non-porous solid tissues, given its spontaneous display of results, user-friendly interface, and convenient hardware connection.

  6. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Visser, M de; Verbeeten, Jr, B J

    1988-06-04

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs.

  7. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    International Nuclear Information System (INIS)

    Visser, M. de; Verbeeten, B.J. Jr.

    1988-01-01

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs

  8. 2D histomorphometric quantification from 3D computerized tomography

    International Nuclear Information System (INIS)

    Lima, Inaya; Oliveira, Luis Fernando de; Lopes, Ricardo T.; Jesus, Edgar Francisco O. de; Alves, Jose Marcos

    2002-01-01

    In the present article, preliminary results are presented showing the application of the tridimensional computerized microtomographic technique (3D-μCT) to bone tissue characterization, through histomorphometric quantification which are based on stereologic concepts. Two samples of human bone were correctly prepared to be submitted to the tomographic system. The system used to realize that process were a radiographic system with a microfocus X-ray tube. Through these three processes, acquisition, reconstruction and quantification, it was possible to get the good results and coherent to the literature data. From this point, it is intended to compare these results with the information due the conventional method, that is, conventional histomorphometry. (author)

  9. Physicians' and Nurses' Opinions about the Impact of a Computerized Provider Order Entry System on Their Workflow.

    Science.gov (United States)

    Ayatollahi, Haleh; Roozbehi, Masoud; Haghani, Hamid

    2015-01-01

    In clinical practices, the use of information technology, especially computerized provider order entry (CPOE) systems, has been found to be an effective strategy to improve patient care. This study aimed to compare physicians' and nurses' views about the impact of CPOE on their workflow. This case study was conducted in 2012. The potential participants included all physicians (n = 28) and nurses (n = 145) who worked in a teaching hospital. Data were collected using a five-point Likert-scale questionnaire and were analyzed using SPSS version 18.0. The results showed a significant difference between physicians' and nurses' views about the impact of the system on interorganizational workflow (p = .001) and working relationships between physicians and nurses (p = .017). Interorganizational workflow and working relationships between care providers are important issues that require more attention. Before a CPOE system is designed, it is necessary to identify workflow patterns and hidden structures to avoid compromising quality of care and patient safety.

  10. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  11. Integration of MSFC Usability Lab with Usability Testing

    Science.gov (United States)

    Cheng, Yiwei; Richardson, Sally

    2010-01-01

    As part of the Stage Analysis Branch, human factors engineering plays an important role in relating humans to the systems of hardware and structure designs of the new launch vehicle. While many branches are involved in the technical aspects of creating a launch vehicle, human factors connects humans to the scientific systems with the goal of improving operational performance and safety while reducing operational error and damage to the hardware. Human factors engineers use physical and computerized models to visualize possible areas for improvements to ensure human accessibility to components requiring maintenance and that the necessary maintenance activities can be accomplished with minimal risks to human and hardware. Many methods of testing are used to fulfill this goal, such as physical mockups, computerized visualization, and usability testing. In this analysis, a usability test is conducted to test how usable a website is to users who are and are not familiar with it. The testing is performed using participants and Morae software to record and analyze the results. This analysis will be a preliminary test of the usability lab in preparation for use in new spacecraft programs, NASA Enterprise, or other NASA websites. The usability lab project is divided into two parts: integration of the usability lab and a preliminary test of the usability lab.

  12. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  13. Computerized tomography

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the design of computerized tomographic X-ray equipment are described which lead to improvements in the mechanical properties, speed and size of scanning areas. The method envisages the body being scanned as a two-dimensional matrix of elements arising from a plurality of concentric rings. The concentric centre need not coincide with the axis of rotation. The procedures for rotation of the X-ray beam and detectors around the patient and for translating the measured information into attenuation coefficients for each matrix element of the body are described in detail. Explicit derivations are given for the mathematical formulae used. (U.K.)

  14. Cognitive performance in relapsing remitting multiple sclerosis: A longitudinal study in daily practice using a brief computerized cognitive battery

    Directory of Open Access Journals (Sweden)

    Jacquerye Philippe

    2011-06-01

    Full Text Available Abstract Background There is need for a cognitive test battery that can be easily used in clinical practice to detect or monitor cognitive performance in patients with multiple sclerosis (MS. In order to conduct, in this patient group, a preliminary investigation of the validity and utility of a brief computerized battery, the Cognitive Drug Research (CDR battery, we longitudinally assessed cognition in patients with relapsing remitting (RR MS. Methods Forty-three mildly disabled, clinically active RRMS patients were repeatedly assessed with the Digit Symbol Substitution Test (DSST, Paced Auditory Serial Addition Test (PASAT and five composite scores derived from the CDR computerized cognitive test system (CDR System: Power of Attention, Continuity of Attention, Quality of Working Memory, Quality of Episodic Memory and Speed of Memory. The Multiple Sclerosis Functional Composite (MSFC and Expanded Disability Status Scale (EDSS measured disability. Results The composite scores from the CDR battery generally showed excellent test-retest reliability over the repeated assessments, though was low on occasions for the Quality of Working Memory and Quality of Episodic Memory measures. The CDR measures tended to be highly correlated with other measures of cognition (DSST and PASAT and were also strongly related to disability (EDSS and MSFC. Baseline scores indicated large impairments to visual information processing speed and attention (DSST, Cohen's d 1.1; Power of Attention d 1.4 [reaction time on tasks of focussed and sustained attention], and a moderate impairment both to sustained attention (Continuity of Attention d 0.6 and complex information processing speed (Speed of memory d 0.7 [reaction time on tasks of working and episodic Memory], when compared to normative data derived from healthy volunteers enrolled in a series of separate, prior clinical trials. Working memory (Quality of Working Memory and episodic memory (Quality of Episodic Memory

  15. Computerized tomography of the mandibular joints and masticatory muscles

    International Nuclear Information System (INIS)

    Huels, A.B.

    1981-01-01

    A methodology for computerized tomography of the mandibular joints was developed and applied in 80 test persons. Imaging of the mandibular joints is possible with a tomographic technique with 5 mm-overlap, full utilisation of the enlargement capacity of the imaging device, and combined use of transversal and coronary tomography. The method yields full latero-medial, cranio-caudal and anterior-posterior views of the condyle and fossa contours, free of interferences and of distortions caused by the projection. Positional diagnoses are thus possible as well as diagnoses of pathological structural changes. (orig./MG) [de

  16. Computerized operation of the DIII-D neutral beams

    International Nuclear Information System (INIS)

    Glad, A.S.; Tooker, J.F.

    1986-01-01

    Operation of the DIII-D neutral beams utilizes computerized control to provide routine tokamak beam heating shots and an effective method for automatic ion source operation. Computerized control reduces operational complexity, thus providing consistent reliability and availability of beams and a significant reduction in the the costs of routine operation. The objectives in implementing computerized control for operation were: (1) to improve operator efficiency for controlling multiple beam lines and increasing beam availability through standard procedures, (2) to provide a simplified scheme that operators and coordinators can construct and maintain, and (3) to provide a single integrated mechanism for both tokamak operation and automatic source conditioning. The years of experience in operating neutral beams at Doublet III provided the data necessary to meet the objectives. The method for computerized control consisted of three integrated functions: (1) a structured command language was implemented to provide the mechanism for automatically sequencing beams, (2) a historical file was constructed from the operational parameters to characterize the ion source, and consists of data from approximately 100,000 beam shots, and (3) procedures were developed integrating the language to the historical file for normal operation and source conditioning. This paper describes the method for sequencing beams automatically, the structure of the historical data file, and the procedures which integrate the historical data with tokamak operation and automatic source conditioning

  17. Accessing leaking underground storage tank case studies and publications through the EPA's Computerized On-Line Information System (COLIS)

    International Nuclear Information System (INIS)

    Hillger, R.; Tibay, P.

    1991-01-01

    The US EPA's regulations for underground storage tanks (USTs) require corrective action to be taken in response to leaking USTs. Recent developments of UST programs nationwide as well as the introduction of new technologies to clean up UST sites have increased the diversity of experience levels among personnel involved with this type of work. The EPA's Computerized On-Line Information System (COLIS) has been developed to facilitate technology transfer among the personnel involved in UST cleanup. The system allows for the quick and simple retrieval of data relating to UST incidents, as well as other hazardous waste-related information. The system has been used by response personnel at all levels of government, academia, and private industry. Although it has been in existence for many years, users are just now realizing the potential wealth of information stored in this system. COLIS access can be accomplished via telephone lines utilizing a personal computer and a modem

  18. Computerized data treatment technology

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Maddox, J.H.; Wren, H.F.

    1977-01-01

    The Savannah River Laboratory (SRL) has accepted responsibility for a hydrogeochemical and stream-sediment reconnaissance in 25 eastern states as part of the National Uranium Resource Evaluation (NURE). SRL has developed a computerized program for recording, processing, updating, retrieving, and analyzing hydrogeochemical data from this reconnaissance. This program will handle an expected 150 million bytes of hydrogeochemical data from 150,000 to 200,000 sample sites over the next four years. The SRL--NURE hydrogeochemical data management system is written in FORTRAN IV for an IBM System 360/195 computer and is designed to easily accommodate changes in types of collected data and input format. As the data become available, they are accepted and combined with relevant data already in the system. SRL also developed a sample inventory and control system and a graphics and analysis system. The sample inventory and control system accounts for the movements of all samples and forms from initial receipt through final storage. Approximately six million sample movements are expected. The graphics and analysis system provides easily usable programs for reporting and interpreting data. Because of the large volume of data to be interpreted, the graphics and analysis system plays a central role in the hydrogeochemical program. Programs developed to provide two- and three-dimensional plots of sampled geographic areas show concentrations and locations of individual variables which are displayed and reproduced photographically. Pattern recognition techniques are also available, and they allow multivariate data to be categorized into ''clusters,'' which may indicate sites favorable for uranium exploration

  19. Computerized tomography in atypical Pott's disease

    International Nuclear Information System (INIS)

    Cabrera, M.N.B.; Wang, E.H.M.

    1993-01-01

    Classical Pott's disease is described as a two-vertebrae disease with the destruction of the intervening invertebral disc. Computerized tomography has been used in the differential diagnosis of spine infections and neoplasms. We reviewed CT scans of patients seen at the Philippine General Hospital over a two-year period with atypical presentations of atypical tuberculous spondylitis. We used the computerized tomography findings described as characteristic of classical Pott's disease as criteria in evaluating the CT scans of patients diagnosed to have Atypical Pott's Disease. Although the number of patients prevented sensitivity and specificity studies to be done, our results strongly suggest that the same CT criteria used to diagnose Classical Pott's Disease may also be used to diagnose Pott's disease in its atypical form. (Author.). 13 refs

  20. Work improvement by computerizing the process of shielding block production

    International Nuclear Information System (INIS)

    Kang, Dong Hyuk; Jeong, Do Hyeong; Kang, Dong Yoon; Jeon, Young Gung; Hwang, Jae Woong

    2013-01-01

    Introducing CR (Computed Radiography) system created a process of printing therapy irradiation images and converting the degree of enlargement. This is to increase job efficiency and contribute to work improvement using a computerized method with home grown software to simplify this process, work efficiency. Microsoft EXCEL (ver. 2007) and VISUAL BASIC (ver. 6.0) have been used to make the software. A window for each shield block was designed to enter patients' treatment information. Distances on the digital images were measured, the measured data were entered to the Excel program to calculate the degree of enlargement, and printouts were produced to manufacture shield blocks. By computerizing the existing method with this program, the degree of enlargement can easily be calculated and patients' treatment information can be entered into the printouts by using macro function. As a result, errors in calculation which may occur during the process of production or errors that the treatment information may be delivered wrongly can be reduced. In addition, with the simplification of the conversion process of the degree of enlargement, no copy machine was needed, which resulted in the reduction of use of paper. Works have been improved by computerizing the process of block production and applying it to practice which would simplify the existing method. This software can apply to and improve the actual conditions of each hospital in various ways using various features of EXCEL and VISUAL BASIC which has already been proven and used widely