WorldWideScience

Sample records for computerized diagnostic information

  1. A computerized legal information management system | Ohiagu ...

    African Journals Online (AJOL)

    A computerized legal information management system. ... process through the filling system using the survey research methodology. ... A framework for the design and implementation of a legal information management system was presented.

  2. Computerized management information systems and organizational structures

    Science.gov (United States)

    Zannetos, Z. S.; Sertel, M. R.

    1970-01-01

    The computerized management of information systems and organizational structures is discussed. The subjects presented are: (1) critical factors favoring centralization and decentralization of organizations, (2) classification of organizations by relative structure, (3) attempts to measure change in organization structure, and (4) impact of information technology developments on organizational structure changes.

  3. Dose evaluation in diagnostic for computerized tomography

    International Nuclear Information System (INIS)

    Flores, W.; Borges, J.C.; Mota, H.

    1998-01-01

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  4. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Visser, M de; Verbeeten, Jr, B J

    1988-06-04

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs.

  5. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    International Nuclear Information System (INIS)

    Visser, M. de; Verbeeten, B.J. Jr.

    1988-01-01

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs

  6. Computerized reactor pressure vessel materials information system

    International Nuclear Information System (INIS)

    Strosnider, J.; Monserrate, C.; Kenworthy, L.D.; Tether, C.D.

    1980-10-01

    A computerized information system for storage and retrieval of reactor pressure vessel materials data was established, as part of Task Action Plan A-11, Reactor Vessel Materials Toughness. Data stored in the system are necessary for evaluating the resistance of reactor pressure vessels to flaw-induced fracture. This report includes (1) a description of the information system; (2) guidance on accessing the system; and (3) a user's manual for the system

  7. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  8. Computerized information management for institutional review boards.

    Science.gov (United States)

    Hood, Maureen N; Gugerty, Brian; Levine, Richard; Ho, Vincent B

    2005-01-01

    The use of human subjects for medical research in most industrialized nations requires the scientific and ethical scrutiny of research proposals by a governing institutional review board (IRB) or its equivalent. As part of their primary charge to protect human subjects, IRBs are responsible for the regulatory oversight of not only the research protocol itself but also the research conduct of the investigators and, if applicable, the funding sponsor. This article will discuss the regulatory requirements for an accurate account of IRB protocols and investigators and present an overview of the general flow of information for an IRB protocol. The current and potential uses of information management systems by IRBs will also be reviewed and accompanied by a discussion of the potential advantages and disadvantages of various computerized information systems for management of clinical research.

  9. Radiation protection in computerized tomography diagnostics; Strahlenschutz in der Computertomografie

    Energy Technology Data Exchange (ETDEWEB)

    Grust, Andreas [Radiologie am Hauptbahnhof, Duesseldorf (Germany)

    2012-11-01

    The essential advantage of computerized tomography (CT) compared to projecting radiographic techniques is the display of organs free of superposition using a 3D data set and additional enhanced contrast resolution. CT is a mostly objective and examination-independent technique that has developed towards an indispensable tool for tumor diagnostics and traumatology. With respect to the total amount of X-ray diagnostic examinations CT is a rather seldom used technique, nevertheless causing a disproportionately high amount of the collective effective dose of the German population. This disadvantage triggers the necessity to work on a radiation dose reduction. The author discusses the issues X-ray tube current reduction, layer thickness, pitch factor, scan length, dose modulation, adaptive collimation, and iterative reconstruction.

  10. Analysis of errors during medical and computerized diagnostics of spherical lung neoplasms

    International Nuclear Information System (INIS)

    Pozmogov, A.I.; Petruk, D.A.

    1985-01-01

    Reasons for errors in medical and computerized diagnostics of spherical lung neoplasms are studied based on material of 212 case records and clinicoroentgenological data; it should promote improvement of their diagnostics

  11. Diagnostic medical imaging systems. X-ray radiography and angiography, computerized tomography, nuclear medicine, NMR imaging, sonography, integrated image information systems. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Morneburg, H.

    1995-01-01

    This third edition is based on major review and updating work. Many recent developments have been included, as for instance novel systems for fluoroscopy and mammography, spiral CT and electron beam CT, nuclear medical tomography ( SPECT and PET), novel techniques for fast NMR imaging, spectral and colour coded duplex sonography, as well as a new chapter on integrated image information systems, including network installations. (orig.) [de

  12. Computerized tomography and its diagnostic value in the imaging of limbs

    International Nuclear Information System (INIS)

    Myllylae, V.; Tervonen, O.; Paeivaensalo, M.; Jalovaara, P.; Merikanto, J.; Maekaeraeinen, H.; Oulu Univ.

    1987-01-01

    The application of computerized tomography in skeletal diagnostics has many advantages over plain film radiography. Its use as a supplementary technique in traumatology and oncology is strongly advised. (orig.) [de

  13. A COMPUTERIZED DIAGNOSTIC COMPLEX FOR RELIABILITY TESTING OF ELECTRIC MACHINES

    Directory of Open Access Journals (Sweden)

    O.О. Somka

    2015-06-01

    Full Text Available Purpose. To develop a diagnostic complex meeting the criteria and requirements for carrying out accelerated reliability test and realizing the basic modes of electric machines operation and performance of the posed problems necessary in the process of such test. Methodology. To determine and forecast the indices of electric machines reliability in accordance with the statistic data of repair plants we have conditionally divided them into structural parts that are most likely to fail. We have preliminarily assessed the state of each of these parts, which includes revelation of faults and deviations of technical and geometric parameters. We have determined the analyzed electric machine controlled parameters used for assessment of quantitative characteristics of reliability of these parts and electric machines on the whole. Results. As a result of the research, we have substantiated the structure of a computerized complex for electric machines reliability test. It allows us to change thermal and vibration actions without violation of the physics of the processes of aging and wearing of the basic structural parts and elements material. The above mentioned makes it possible to considerably reduce time spent on carrying out electric machines reliability tests and improve trustworthiness of the data obtained as a result of their performance. Originality. A special feature of determination of the controlled parameters consists in removal of vibration components in the idle mode and after disconnection of the analyzed electric machine from the power supply with the aim of singling out the vibration electromagnetic component, fixing the degree of sparking and bend of the shaft by means of phototechnique and local determination of structural parts temperature provided by corresponding location of thermal sensors. Practical value. We have offered a scheme of location of thermal and vibration sensors, which allows improvement of parameters measuring accuracy

  14. Wilderness Management... A Computerized System for Summarizing Permit Information

    Science.gov (United States)

    Gary H. Elsner

    1972-01-01

    Permits were first needed for visits to wilderness areas in California during summer 1971. A computerized system for analyzing these permits and summarizing information from them has been developed. It produces four types of summary tables: point-of-origin of visitors; daily variation in total number of persons present; variations in group size; and variations in...

  15. Computerized health information and the demand for medical care.

    Science.gov (United States)

    Wagner, Todd H; Jimison, Holly B

    2003-01-01

    Consumer health information, once the domain of books and booklets, has become increasingly digitized and available on the Internet. This study assessed the effect of using computerized health information on consumers' demand for medical care. The dependent variable was self-reported number of visits to the doctor in the past year. The key independent variable was the use of computerized health information, which was treated as endogenous. We tested the effect of using computerized health information on physician visits using ordinary least squares, instrumental variables, fixed effects, and fixed-effects instrumental variables models. The instrumental variables included exposure to the Healthwise Communities Project, a community-wide health information intervention; computer ownership; and Internet access. Random households in three cities were mailed questionnaires before and after the Healthwise Communities Project. In total, 5909 surveys were collected for a response rate of 54%. In both the bivariate and the multivariate analyses, the use of computerized health information was not associated with self-reported entry into care or number of visits. The instrumental variables models also found no differences, with the exception that the probability of entering care was significantly greater with the two-stage conditional logit model (P information is intuitively appealing, we found little evidence of an association between using a computer for health information and self-reported medical visits in the past year. This study used overall self-reported utilizations as the dependent variable, and more research is needed to determine whether health information affects the health production function in other important ways, such as the location of care, the timing of getting care, or the intensity of treatment.

  16. Diagnostic perspectives of mobile x-ray computerized tomography

    International Nuclear Information System (INIS)

    Portnoj, L.M.; Dibirov, M.P.; Denisova, L.B.

    1992-01-01

    Mobile x-ray computerized tomography (CT) and an organization and methodological scheme of its application were assessed. CT is realized in special hospitals of large regions, where the patients with the optimal indications for CT are assembled. Over 15000 examinations were carried out with the use of the suggested CT program over 4 years, that resulted in detection of 1295 brain tumors, 804 cases with neoplastic involvement of the abdominal cavity and the retroperitoneal space. Wide application of mobile CT devices according to the program will help to decide the problem of unavailability of such examinations. One mobile device may replace 3 permanent CT devices

  17. A Computerized Hospital Patient Information Management System

    Science.gov (United States)

    Wig, Eldon D.

    1982-01-01

    The information processing needs of a hospital are many, with varying degrees of complexity. The prime concern in providing an integrated hospital information management system lies in the ability to process the data relating to the single entity for which every hospital functions - the patient. This paper examines the PRIMIS computer system developed to accommodate hospital needs with respect to a central patient registry, inpatients (i.e., Admission/Transfer/Discharge), and out-patients. Finally, the potential for expansion to permit the incorporation of more hospital functions within PRIMIS is examined.

  18. An automated computerized auscultation and diagnostic system for pulmonary diseases.

    Science.gov (United States)

    Abbas, Ali; Fahim, Atef

    2010-12-01

    Respiratory sounds are of significance as they provide valuable information on the health of the respiratory system. Sounds emanating from the respiratory system are uneven, and vary significantly from one individual to another and for the same individual over time. In and of themselves they are not a direct proof of an ailment, but rather an inference that one exists. Auscultation diagnosis is an art/skill that is acquired and honed by practice; hence it is common to seek confirmation using invasive and potentially harmful imaging diagnosis techniques like X-rays. This research focuses on developing an automated auscultation diagnostic system that overcomes the limitations inherent in traditional auscultation techniques. The system uses a front end sound signal filtering module that uses adaptive Neural Networks (NN) noise cancellation to eliminate spurious sound signals like those from the heart, intestine, and ambient noise. To date, the core diagnosis module is capable of identifying lung sounds from non-lung sounds, normal lung sounds from abnormal ones, and identifying wheezes from crackles as indicators of different ailments.

  19. Computerized diagnostic data analysis and 3-D visualization

    International Nuclear Information System (INIS)

    Schuhmann, D.; Haubner, M.; Krapichler, C.; Englmeier, K.H.; Seemann, M.; Schoepf, U.J.; Gebicke, K.; Reiser, M.

    1998-01-01

    Purpose: To survey methods for 3D data visualization and image analysis which can be used for computer based diagnostics. Material and methods: The methods available are explained in short terms and links to the literature are presented. Methods which allow basic manipulation of 3D data are windowing, rotation and clipping. More complex methods for visualization of 3D data are multiplanar reformation, volume projections (MIP, semi-transparent projections) and surface projections. Methods for image analysis comprise local data transformation (e.g. filtering) and definition and application of complex models (e.g. deformable models). Results: Volume projections produce an impression of the 3D data set without reducing the data amount. This supports the interpretation of the 3D data set and saves time in comparison to any investigation which requires examination of all slice images. More advanced techniques for visualization, e.g. surface projections and hybrid rendering visualize anatomical information to a very detailed extent, but both techniques require the segmentation of the structures of interest. Image analysis methods can be used to extract these structures (e.g. an organ) from the image data. Discussion: At the present time volume projections are robust and fast enough to be used routinely. Surface projections can be used to visualize complex and presegmented anatomical features. (orig.) [de

  20. Examinations and patient management in radiologic diagnostics by means of a computerized data-processing communications system

    International Nuclear Information System (INIS)

    Klotz, E.; Remplik, V.; Opfer, M.; Wilde, E.

    1986-01-01

    Concept, realization and a two-year experience in routine use of a computerized data-processing communications system supporting the central radiology department in a 1.625-bed, municipal hospital are discussed. Via the hospital ward-linked terminal network, routine X-ray examination is so ordered, that individual medical case information is provided, which certifies qualified clinical and diagnostic procedure along with good patient preparation and transportation. Complete information and documentation are also ensured. It was shown, that good motivation among involved radiologists and their close working-association with other departments are mandatory from the start to maintain exact time schedules and satisfactory completion of ordered X-ray procedures. Subsequently, the assistance through computerized data-processing becomes an accepted help - so far as it is appropriately used - as time goes by in its routine use. (orig.) [de

  1. Carolina Power and Light Company's computerized Radiological Information Management System

    International Nuclear Information System (INIS)

    Meyer, B.A.

    1987-01-01

    Carolina Power and Lignt Company has recently implement a new version of their computerized Radiological Information management System. The new version was programmed in-house and is run on the Company's mainframe computers. In addition to providing radiation worker dose histories and current dose updates, the system provides real-time access control for all three of the Company's nuclear plants such as respirator and survey equipment control and inventory, TLD QC records, and many other functions

  2. Diagnostic Yield of Transbronchial Biopsy in Comparison to High Resolution Computerized Tomography in Sarcoidosis Cases

    Science.gov (United States)

    Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan

    2018-04-25

    This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License

  3. Development of a computerized system for performance monitoring and diagnostics in nuclear power plants

    International Nuclear Information System (INIS)

    Chou, G.H.; Chao, H.J.

    1995-01-01

    An on-line computerized system for thermal performance monitoring and diagnostics has been developed at the Institute of Nuclear Energy Research (INER). It was the product of the ChinShan plant performance Monitoring, Analysis and Diagnostics Expert System (CS-MADES) project sponsored by Taiwan Power Company (TPC). The system can carry out turbine performance monitoring and analysis during normal operation, and yield diagnostic results of component degradation after finding out the missing generation problems. Three subsystems were generated to support the whole system framework. They are Test Data Processing Subsystem (TDPS), On-line Monitoring and Analysis Subsystem (OMAS), and Thermal Performance Diagnostics Expert System (TPDES). Some visible benefits have been gained so far through the prototype system installed at the Chinshan nuclear power station

  4. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  5. Diagnostic Value of Manual and Computerized Methods of Dental Casts Analysis

    Directory of Open Access Journals (Sweden)

    H. Rahimi

    2009-06-01

    Full Text Available Objective: The aim of this study was to evaluate the validity of computerized and manual methods of dental cast analysis.Materials and Methods: Twenty set-ups of upper and lower casts using artificial teeth corresponding to various malocclusions were created for a diagnostic in vitro study. Values of tooth size were calculated from the isolated artificial teeth out of the set-ups, results were considered as a gold standard for the tooth size. Arch width was calculated from the existing set-ups on the dentins.Impressions were taken of the casts with alginate and duplicated with dental stone. Models were measured with digital caliper manually. Then images were taken from the occlusal views of the casts by a digital camera. Measurements were done on digital images with the AutoCAD software.The results of the computerized and manual methods were compared with the gold standard.Intra class correlation coefficient of reliability was used to measure the accuracy ofthe methods and the Friedman technique used to evaluate the significance of differences.Results: Results indicated that all measurements were highly correlated, e.g. gold standard and manual (0.9613-0.9991, gold standard and computerized (0.7118-0.9883, manual and computerized (0.6734-0.9914. Statistically significant differences were present between these methods (P<0.05, but they proved not to be clinically significant.Conclusion: Manual measurement is still the most accurate method when compared to the computerized measurements and the results of measurement by computer should be interpreted with caution.

  6. 15 CFR 950.9 - Computerized Environmental Data and Information Retrieval Service.

    Science.gov (United States)

    2010-01-01

    ... Information Retrieval Service. 950.9 Section 950.9 Commerce and Foreign Trade Regulations Relating to Commerce... Computerized Environmental Data and Information Retrieval Service. The Environmental Data Index (ENDEX... computerized, information retrieval service provides a parallel subject-author-abstract referral service. A...

  7. Computerized tools in psychology: cross cultural and genetically informative studies of memory

    Directory of Open Access Journals (Sweden)

    Ismatullina V.

    2016-01-01

    Full Text Available In this article we presented the computerized tools for psychological studies of memory. The importance of implementing computerized automated tools for psychological studies is discussed. It has been shown that this tools can be used both for cross-cultural and genetically informative studies. The validity of these tools for cross-cultural and genetically informative studies of memory can be seen as the first step to use automated computerized tools for big data collection in psychology.

  8. Analysis of risk in computerized tomography and other diagnostic radiology procedures

    International Nuclear Information System (INIS)

    Mossman, K.L.

    1982-01-01

    Medical practice entails continuous risks to the patient taken in good faith by the physician for the benefit of the patient. Risk of radiation induced cancer death approximates 10(-4) per cGy (rad). Assuming an average whole body dose of 0.1 cGy for many diagnostic X-ray procedures, the probability of radiation-induced cancer death is about 10(-5). The purpose of this paper is to compare the risks of common diagnostic X-ray procedures including computerized tomography (CT) with risks of smoking or automobile travel. Such comparisons should be constructive in putting radiation in perspective and facilitating explanation of risk/benefit to patients

  9. Diagnostic information management system for the evaluation of medical images

    Energy Technology Data Exchange (ETDEWEB)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina

    1985-04-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions.

  10. Diagnostic information management system for the evaluation of medical images

    International Nuclear Information System (INIS)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina.

    1985-01-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions. (author)

  11. Information engineering for molecular diagnostics.

    Science.gov (United States)

    Sorace, J. M.; Ritondo, M.; Canfield, K.

    1994-01-01

    Clinical laboratories are beginning to apply the recent advances in molecular biology to the testing of patient samples. The emerging field of Molecular Diagnostics will require a new Molecular Diagnostics Laboratory Information System which handles the data types, samples and test methods found in this field. The system must be very flexible in regards to supporting ad-hoc queries. The requirements which are shaping the developments in this field are reviewed and a data model developed. Several queries which demonstrate the data models ability to support the information needs of this area have been developed and run. These results demonstrate the ability of the purposed data model to meet the current and projected needs of this rapidly expanding field. PMID:7949937

  12. Computerized systems for on-line management of failures: a state-of-the-art discussion of alarm systems and diagnostic systems applied in the nuclear industry

    International Nuclear Information System (INIS)

    Kim, I.S.

    1994-01-01

    It is now well perceived in the nuclear industry that improving plant information systems is vital for enhancing the operational safety of nuclear power plants. Considerable work is underway worldwide to support operators' decision-making, particularly in their difficult tasks of managing process anomalies on-line. The work includes development of (1) advanced alarm systems, such as various kinds of computer-based alarm processing systems, Critical Function Monitoring System, Success Path Monitoring System and Safety Assessment System II, and (2) real-timer diagnostic systems, such as Disturbance Analysis System, Maryland Operator Advisory System II, Model-Integrated Diagnostic Analysis System, Diagnosis System using Knowledge Engineering Technique, Detailed Diagnosis, and Operator Advisor System. This paper presents a state-of-the-art review of plant information systems for on-line management of failures in nuclear power plants, focusing on the methodological features of computerized alarm systems and diagnostic systems. (author)

  13. Evaluation of computerized health management information system for primary health care in rural India

    Directory of Open Access Journals (Sweden)

    Singh Satyavir

    2010-11-01

    Full Text Available Abstract Background The Comprehensive Rural Health Services Project Ballabgarh, run by All India Institute of Medical Sciences (AIIMS, New Delhi has a computerized Health Management Information System (HMIS since 1988. The HMIS at Ballabgarh has undergone evolution and is currently in its third version which uses generic and open source software. This study was conducted to evaluate the effectiveness of a computerized Health Management Information System in rural health system in India. Methods The data for evaluation were collected by in-depth interviews of the stakeholders i.e. program managers (authors and health workers. Health Workers from AIIMS and Non-AIIMS Primary Health Centers were interviewed to compare the manual with computerized HMIS. A cost comparison between the two methods was carried out based on market costs. The resource utilization for both manual and computerized HMIS was identified based on workers' interviews. Results There have been no major hardware problems in use of computerized HMIS. More than 95% of data was found to be accurate. Health workers acknowledge the usefulness of HMIS in service delivery, data storage, generation of workplans and reports. For program managers, it provides a better tool for monitoring and supervision and data management. The initial cost incurred in computerization of two Primary Health Centers was estimated to be Indian National Rupee (INR 1674,217 (USD 35,622. Equivalent annual incremental cost of capital items was estimated as INR 198,017 (USD 4213. The annual savings is around INR 894,283 (USD 11,924. Conclusion The major advantage of computerization has been in saving of time of health workers in record keeping and report generation. The initial capital costs of computerization can be recovered within two years of implementation if the system is fully operational. Computerization has enabled implementation of a good system for service delivery, monitoring and supervision.

  14. Simplified diagnostic coding sheet for computerized data storage and analysis in ophthalmology.

    Science.gov (United States)

    Tauber, J; Lahav, M

    1987-11-01

    A review of currently-available diagnostic coding systems revealed that most are either too abbreviated or too detailed. We have compiled a simplified diagnostic coding sheet based on the International Coding and Diagnosis (ICD-9), which is both complete and easy to use in a general practice. The information is transferred to a computer, which uses the relevant (ICD-9) diagnoses as database and can be retrieved later for display of patients' problems or analysis of clinical data.

  15. A new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus

    Science.gov (United States)

    Nam, Kyoung Won; Kim, In Young; Kang, Ho Chul; Yang, Hee Kyung; Yoon, Chang Ki; Hwang, Jeong Min; Kim, Young Jae; Kim, Tae Yun; Kim, Kwang Gi

    2012-10-01

    Accurate measurement of binocular misalignment between both eyes is important for proper preoperative management, surgical planning, and postoperative evaluation of patients with strabismus. In this study, we proposed a new computerized diagnostic algorithm that can calculate the angle of binocular eye misalignment photographically by using a dedicated three-dimensional eye model mimicking the structure of the natural human eye. To evaluate the performance of the proposed algorithm, eight healthy volunteers and eight individuals with strabismus were recruited in this study, the horizontal deviation angle, vertical deviation angle, and angle of eye misalignment were calculated and the angular differences between the healthy and the strabismus groups were evaluated using the nonparametric Mann-Whitney test and the Pearson correlation test. The experimental results demonstrated a statistically significant difference between the healthy and strabismus groups (p = 0.015 0.05). The measurements of the two methods were highly correlated (r = 0.969, p human eye to diagnose non-invasively the severity of strabismus.

  16. Diagnostic radiology for head and neck neoplasms with emphasis on computerized tomography

    International Nuclear Information System (INIS)

    Weber, A.L.; Manzione, J.V.

    1986-01-01

    The radiologic evaluation of head and neck neoplasms constitutes an important part in their diagnosis and treatment. The introduction of computerized tomography (CT) and the further development of this modality since 1972 have contributed significantly to the staging of these neoplasms. CT not only demonstrates soft tissue densities, but also bony structures, muscles, fascial planes, opacified vascular structures, and enlarged lymph nodes. CT, however, fails to differentiate the various histologic types of lesions in the majority of cases. Features such as size of the lesion, marginal definition, lytic bone destruction, sclerotic bony reaction, bony expansion, calcific densities, fat content, and obliteration of fascial planes are utilized to delimit the spectrum of diagnostic possibilities. Conventional films including tomography are also indicated as preliminary examinations in the investigation of head and neck neoplasms. They provide a survey of the abnormality in question and form the basis for special studies such as CT and angiography. They are often the first examination to demonstrate a lesion that may be suspected from the history and clinical examination. 13 refs.; 11 figs

  17. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  18. Computerized Diagnostic Assistant for the Automatic Detection of Pneumothorax on Ultrasound: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Shane M. Summers, MD, RDMS

    2016-03-01

    Full Text Available Introduction: Bedside thoracic ultrasound (US can rapidly diagnose pneumothorax (PTX with improved accuracy over the physical examination and without the need for chest radiography (CXR; however, US is highly operator dependent. A computerized diagnostic assistant was developed by the United States Army Institute of Surgical Research to detect PTX on standard thoracic US images. This computer algorithm is designed to automatically detect sonographic signs of PTX by systematically analyzing B-mode US video clips for pleural sliding and M-mode still images for the seashore sign. This was a pilot study to estimate the diagnostic accuracy of the PTX detection computer algorithm when compared to an expert panel of US trained physicians. Methods: This was a retrospective study using archived thoracic US obtained on adult patients presenting to the emergency department (ED between 5/23/2011 and 8/6/2014. Emergency medicine residents, fellows, attending physicians, physician assistants, and medical students performed the US examinations and stored the images in the picture archive and communications system (PACS. The PACS was queried for all ED bedside US examinations with reported positive PTX during the study period along with a random sample of negatives. The computer algorithm then interpreted the images, and we compared the results to an independent, blinded expert panel of three physicians, each with experience reviewing over 10,000 US examinations. Results: Query of the PACS system revealed 146 bedside thoracic US examinations for analysis. Thirteen examinations were indeterminate and were excluded. There were 79 true negatives, 33 true positives, 9 false negatives, and 12 false positives. The test characteristics of the algorithm when compared to the expert panel were sensitivity 79% (95 % CI [63-89] and specificity 87% (95% CI [77-93]. For the 20 images scored as highest quality by the expert panel, the algorithm demonstrated 100% sensitivity

  19. Information security risk management for computerized health information systems in hospitals: a case study of Iran.

    Science.gov (United States)

    Zarei, Javad; Sadoughi, Farahnaz

    2016-01-01

    In recent years, hospitals in Iran - similar to those in other countries - have experienced growing use of computerized health information systems (CHISs), which play a significant role in the operations of hospitals. But, the major challenge of CHIS use is information security. This study attempts to evaluate CHIS information security risk management at hospitals of Iran. This applied study is a descriptive and cross-sectional research that has been conducted in 2015. The data were collected from 551 hospitals of Iran. Based on literature review, experts' opinion, and observations at five hospitals, our intensive questionnaire was designed to assess security risk management for CHISs at the concerned hospitals, which was then sent to all hospitals in Iran by the Ministry of Health. Sixty-nine percent of the studied hospitals pursue information security policies and procedures in conformity with Iran Hospitals Accreditation Standards. At some hospitals, risk identification, risk evaluation, and risk estimation, as well as risk treatment, are unstructured without any specified approach or methodology. There is no significant structured approach to risk management at the studied hospitals. Information security risk management is not followed by Iran's hospitals and their information security policies. This problem can cause a large number of challenges for their CHIS security in future. Therefore, Iran's Ministry of Health should develop practical policies to improve information security risk management in the hospitals of Iran.

  20. Information security risk management for computerized health information systems in hospitals: a case study of Iran

    Science.gov (United States)

    Zarei, Javad; Sadoughi, Farahnaz

    2016-01-01

    Background In recent years, hospitals in Iran – similar to those in other countries – have experienced growing use of computerized health information systems (CHISs), which play a significant role in the operations of hospitals. But, the major challenge of CHIS use is information security. This study attempts to evaluate CHIS information security risk management at hospitals of Iran. Materials and methods This applied study is a descriptive and cross-sectional research that has been conducted in 2015. The data were collected from 551 hospitals of Iran. Based on literature review, experts’ opinion, and observations at five hospitals, our intensive questionnaire was designed to assess security risk management for CHISs at the concerned hospitals, which was then sent to all hospitals in Iran by the Ministry of Health. Results Sixty-nine percent of the studied hospitals pursue information security policies and procedures in conformity with Iran Hospitals Accreditation Standards. At some hospitals, risk identification, risk evaluation, and risk estimation, as well as risk treatment, are unstructured without any specified approach or methodology. There is no significant structured approach to risk management at the studied hospitals. Conclusion Information security risk management is not followed by Iran’s hospitals and their information security policies. This problem can cause a large number of challenges for their CHIS security in future. Therefore, Iran’s Ministry of Health should develop practical policies to improve information security risk management in the hospitals of Iran. PMID:27313481

  1. Computerized information system of the Mochovce nuclear power plant

    International Nuclear Information System (INIS)

    Holik, V.

    1986-01-01

    The computer-based information system for the Mochovce nuclear power plant has a hierarchic structure which incorporates SM 1804 microcomputers and SM 1420 minicomputers. With regard to operation it is divided into two levels: the information system at the level of power plant units and the information system t the level of the whole power plant. The information system of a unit provides the collection of information on the technological equipment of each unit for the operative control of the unit and documentation on unit operation. Each unit has its own independent computer information system. The actual nucleus of each unit information system consists of two computer complexes based on SM 1420 twin computers, mutually substitutional. The power plant level information system provides the processing and output of information for personnel in the central control room of the power plant and for other managerial staff. It uses preprocessed information from the unit information systems and direct information from non-unit installations and from dosimetric control rooms of the power plant units. This information system is also based on a computer complex with two SM 1420 computers. (Z.M.)

  2. Quality indicators in a computerized technology information system

    International Nuclear Information System (INIS)

    Mancuso, C.A.; Hyde, R.A.

    1992-01-01

    An environmental technology information system was developed by EG ampersand G Idaho, Inc. at the Idaho National Engineering Laboratory (INEL) for the Department of Energy (DOE). The purpose of the system is to reduce costs and time associated with evaluating potential remedial alternatives for a waste site. The information system is organized to aid in the CERCLA process by describing the implementability, effectiveness, and cost of many remedial technologies. Technology categories included in the information system include: Institutional Controls, Retrieval, Separation, Characterization, Physical/Chemical Treatment, Biological Treatment, Thermal Treatment, Storage, Transportation, Disposal, Migration Control (containment), Support Systems, Waste Minimization, and Remote Operations. Two hundred and sixty processes are summarized in these technology areas. Information on these processes was collected from EPA publications, books, journal articles, conference proceedings, vendors, DOE publications, and technical experts. The purpose of this paper is to familiarize readers with issues associated with the development of information systems. A major issue is the system and software quality, which can be controlled by configuration management. Another major issue is the documentation of data quality indicators in references used to collect data for the system, which can not be controlled but must be planned for in the review process

  3. Energy for agriculture. A computerized information retrieval system

    Energy Technology Data Exchange (ETDEWEB)

    Stout, B.A.; Myers, C.A. (comps.)

    1979-12-01

    Energy may come from the sun or the earth or be the product of plant materials or agricultural wastes. Whatever its source, energy is indispensable to our way of life, beginning with the production, processing, and distribution of abundant, high quality food and fiber supplies. This specialized bibliography on the subject of energy for agriculture contains 2613 citations to the literature for 1973 through May 1979. Originally issued by Michigan State University (MSU), it is being reprinted and distributed by the U.S. Department of Agriculture. The literature citations will be incorporated into AGRICOLA (Agricultural On-Line Access), the comprehensive bibliographic data base maintained by Technical Information Systems (TIS), a component of USDA's Science and Education Administration (SEA). The citations and the listing of research projects will be combined with other relevant references to provide a continuously updated source of information on energy programs in the agricultural field. No abstracts are included.

  4. Tight integration of computerized procedures with plant information at the South Texas Project

    International Nuclear Information System (INIS)

    Brtis, J.S.; Green, T.

    1996-01-01

    This paper describes a unique undertaking that is underway at Houston Lighting and Power's South Texas Project (STP). The paper presents an information upgrade project that uses expert system technologies to computerize design change procedures and to tightly integrate the resulting on-line, interactive procedures with the on-line information that design change activities use and generate. This effort will show how procedure computerization can leverage the large investments in plant data. The expected benefits include reduced costs and improved quality of design change work, plus a significant reduction in the burden of configuration management that comes from design changes. Both process computerization and the integration of process with data are being implemented at STP. This work is part of a major migration of information from a mainframe to a LAN platform. This paper will be of greatest interest to those involved in: (1) configuration management, (2) coordinating information to support design change procedures, (3) plant information management, and (4) business process reengineering

  5. A computerized energy systems code and information library at Soreq

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, I; Shapira, M; Caner, D; Sapier, D [Israel Atomic Energy Commission, Yavne (Israel). Soreq Nuclear Research Center

    1996-12-01

    In the framework of the contractual agreement between the Ministry of Energy and Infrastructure and the Division of Nuclear Engineering of the Israel Atomic Energy Commission, both Soreq-NRC and Ben-Gurion University have agreed to establish, in 1991, a code center. This code center contains a library of computer codes and relevant data, with particular emphasis on nuclear power plant research and development support. The code center maintains existing computer codes and adapts them to the ever changing computing environment, keeps track of new code developments in the field of nuclear engineering, and acquires the most recent revisions of computer codes of interest. An attempt is made to collect relevant codes developed in Israel and to assure that proper documentation and application instructions are available. En addition to computer programs, the code center collects sample problems and international benchmarks to verify the codes and their applications to various areas of interest to nuclear power plant engineering and safety evaluation. Recently, the reactor simulation group at Soreq acquired, using funds provided by the Ministry of Energy and Infrastructure, a PC work station operating under a Linux operating system to give users of the library an easy on-line way to access resources available at the library. These resources include the computer codes and their documentation, reports published by the reactor simulation group, and other information databases available at Soreq. Registered users set a communication line, through a modem, between their computer and the new workstation at Soreq and use it to download codes and/or information or to solve their problems, using codes from the library, on the computer at Soreq (authors).

  6. A computerized energy systems code and information library at Soreq

    International Nuclear Information System (INIS)

    Silverman, I.; Shapira, M.; Caner, D.; Sapier, D.

    1996-01-01

    In the framework of the contractual agreement between the Ministry of Energy and Infrastructure and the Division of Nuclear Engineering of the Israel Atomic Energy Commission, both Soreq-NRC and Ben-Gurion University have agreed to establish, in 1991, a code center. This code center contains a library of computer codes and relevant data, with particular emphasis on nuclear power plant research and development support. The code center maintains existing computer codes and adapts them to the ever changing computing environment, keeps track of new code developments in the field of nuclear engineering, and acquires the most recent revisions of computer codes of interest. An attempt is made to collect relevant codes developed in Israel and to assure that proper documentation and application instructions are available. En addition to computer programs, the code center collects sample problems and international benchmarks to verify the codes and their applications to various areas of interest to nuclear power plant engineering and safety evaluation. Recently, the reactor simulation group at Soreq acquired, using funds provided by the Ministry of Energy and Infrastructure, a PC work station operating under a Linux operating system to give users of the library an easy on-line way to access resources available at the library. These resources include the computer codes and their documentation, reports published by the reactor simulation group, and other information databases available at Soreq. Registered users set a communication line, through a modem, between their computer and the new workstation at Soreq and use it to download codes and/or information or to solve their problems, using codes from the library, on the computer at Soreq (authors)

  7. Process information displays from a computerized nuclear materials control and accounting system

    International Nuclear Information System (INIS)

    Ellis, J.H.

    1981-11-01

    A computerized nuclear materials control and accounting system is being developed for an LWR spent fuel reprocessing facility. This system directly accesses process instrument readings, sample analyses, and outputs of various on-line analytical instruments. In this paper, methods of processing and displaying this information in ways that aid in the efficient, timely, and safe control of the chemical processes of the facility are described

  8. The diagnostic value of cranial computerized tomography in exogenous psychoses and mental disorders associated with organic diseases

    International Nuclear Information System (INIS)

    Strobl, G.; Reisner, Th.; Zeiler, K.; Vienna Univ.

    1980-01-01

    205 patients hospitalized in a psychiatric department were subjected to cranial computerized tomography. The diagnosis on discharge according to the ICD key in each case was ''psychoses or mental disorders associated with physical conditions''. Pathological findings were obtained in 67.8% of the patients. In the case of space-occupying lesions the connection between psychiatric symptoms and syndromes and the underlying organic disease is obvious. Moreover, with inflammatory, vascular or traumatic diseases, a relationship to focal lesions found on the computer tomography appears likely if backed by appropriate neurological indications in the history or an clinical examinations. However, when alterations signifying diffuse brain atrophy are obtained on computer tomography any connections with psychiatric features should be very critically evaluated and, in individual cases, such connections had better not be looked for at all. Especially in cases of psychoses or mental disorders associated with physical conditions cranial computerized tomography is of high diagnostic value and the indications for its implementation in these cases should be judged very leniently. (author)

  9. Computerized analysis of isometric tension studies provides important additional information about vasomotor activity

    Directory of Open Access Journals (Sweden)

    Vincent M.B.

    1997-01-01

    Full Text Available Concentration-response curves of isometric tension studies on isolated blood vessels are obtained traditionally. Although parameters such as Imax, EC50 and pA2 may be readily calculated, this method does not provide information on the temporal profile of the responses or the actual nature of the reaction curves. Computerized data acquisition systems can be used to obtain average data that represent a new source of otherwise inaccessible information, since early and late responses may be observed separately in detail

  10. Diagnostic causal reasoning with verbal information.

    Science.gov (United States)

    Meder, Björn; Mayrhofer, Ralf

    2017-08-01

    In diagnostic causal reasoning, the goal is to infer the probability of causes from one or multiple observed effects. Typically, studies investigating such tasks provide subjects with precise quantitative information regarding the strength of the relations between causes and effects or sample data from which the relevant quantities can be learned. By contrast, we sought to examine people's inferences when causal information is communicated through qualitative, rather vague verbal expressions (e.g., "X occasionally causes A"). We conducted three experiments using a sequential diagnostic inference task, where multiple pieces of evidence were obtained one after the other. Quantitative predictions of different probabilistic models were derived using the numerical equivalents of the verbal terms, taken from an unrelated study with different subjects. We present a novel Bayesian model that allows for incorporating the temporal weighting of information in sequential diagnostic reasoning, which can be used to model both primacy and recency effects. On the basis of 19,848 judgments from 292 subjects, we found a remarkably close correspondence between the diagnostic inferences made by subjects who received only verbal information and those of a matched control group to whom information was presented numerically. Whether information was conveyed through verbal terms or numerical estimates, diagnostic judgments closely resembled the posterior probabilities entailed by the causes' prior probabilities and the effects' likelihoods. We observed interindividual differences regarding the temporal weighting of evidence in sequential diagnostic reasoning. Our work provides pathways for investigating judgment and decision making with verbal information within a computational modeling framework. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Information theoretic quantification of diagnostic uncertainty.

    Science.gov (United States)

    Westover, M Brandon; Eiseman, Nathaniel A; Cash, Sydney S; Bianchi, Matt T

    2012-01-01

    Diagnostic test interpretation remains a challenge in clinical practice. Most physicians receive training in the use of Bayes' rule, which specifies how the sensitivity and specificity of a test for a given disease combine with the pre-test probability to quantify the change in disease probability incurred by a new test result. However, multiple studies demonstrate physicians' deficiencies in probabilistic reasoning, especially with unexpected test results. Information theory, a branch of probability theory dealing explicitly with the quantification of uncertainty, has been proposed as an alternative framework for diagnostic test interpretation, but is even less familiar to physicians. We have previously addressed one key challenge in the practical application of Bayes theorem: the handling of uncertainty in the critical first step of estimating the pre-test probability of disease. This essay aims to present the essential concepts of information theory to physicians in an accessible manner, and to extend previous work regarding uncertainty in pre-test probability estimation by placing this type of uncertainty within a principled information theoretic framework. We address several obstacles hindering physicians' application of information theoretic concepts to diagnostic test interpretation. These include issues of terminology (mathematical meanings of certain information theoretic terms differ from clinical or common parlance) as well as the underlying mathematical assumptions. Finally, we illustrate how, in information theoretic terms, one can understand the effect on diagnostic uncertainty of considering ranges instead of simple point estimates of pre-test probability.

  12. Diagnostic significance of elements in hair with esophageal cancer by computerized pattern recognition and PIXE

    International Nuclear Information System (INIS)

    Sha Yin; Liu Pingsheng; Zhang Peiqun; Dong Yulan; Yang Zhenjun; Wu Yue; Li Jingxiu

    1994-01-01

    The concentration of 12 elements in 414 hair samples of male adults from esophageal cancer group(ECG), serious esophagus epithelial cell hyperplasia group (SEECHG) and normal control group (NCG) were determined by PIXE. By at t-test it is found that significant differences exist for 10 elements (Si, S, Ca, Cr, Mn, Fe, Ni, Cu, Pb and Sr) between ECG and NCG and for 9 elements (Si, P, S, Ca, Cr, Mn, Fe, Ni and Zn) between SEECHG and NCG. The three types of persons mentioned above were classified by Mahalanobis distance discriminatory analysis (one of the computerized pattern recognition methods). The results show that the ratio of correct classification is around 72%, suggesting that this may become a promising method for the early diagnosis of esophageal cancer

  13. Dose evaluation in diagnostic for computerized tomography; Evaluacion de dosis en diagnostico por tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Flores, W.; Borges, J.C.; Mota, H. [Universidad Federal de Rio de Janeiro, PEN/COPPE/UFRJ. Caixa Postal 68509. 21945-970 Rio de Janeiro (Brazil)

    1998-12-31

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  14. Using three-dimensional-computerized tomography as a diagnostic tool for temporo-mandibular joint ankylosis: a case report.

    Science.gov (United States)

    Kao, S Y; Chou, J; Lo, J; Yang, J; Chou, A P; Joe, C J; Chang, R C

    1999-04-01

    Roentgenographic examination has long been a useful diagnostic tool for temporo-mandibular joint (TMJ) disease. The methods include TMJ tomography, panoramic radiography and computerized tomography (CT) scan with or without injection of contrast media. Recently, three-dimensional CT (3D-CT), reconstructed from the two-dimensional image of a CT scan to simulate the soft tissue or bony structure of the real target, was proposed. In this report, a case of TMJ ankylosis due to traumatic injury is presented. 3D-CT was employed as one of the presurgical roentgenographic diagnostic tools. The conventional radiographic examination including panoramic radiography and tomography showed lesions in both sides of the mandible. CT scanning further suggested that the right-sided lesion was more severe than that on the left. With 3D-CT image reconstruction the size and extent of the lesions were clearly observable. The decision was made to proceed with an initial surgical approach on the right side. With condylectomy and condylar replacement using an autogenous costochondral graft on the right side, the range of mouth opening improved significantly. In this case report, 3D-CT demonstrates its advantages as a tool for the correct and precise diagnosis of TMJ ankylosis.

  15. Computerized information system on the impacts of coal-fired energy development in the Southwest

    International Nuclear Information System (INIS)

    Layton, D.W.

    1975-01-01

    An important part of the process of assessing the environmental impacts of coal-fired energy development in the Southwest is the transfer of information between electric utilities, federal agencies, and the interested public. There are, however, several problems associated with the transfer of information among the different groups. The acquisition of factual material on power projects by the interested public, for example, is adversely affected by the sufficiency, convenience, and credibility of present sources. Efforts of electric utilities and federal agencies to effectively communicate impact information are hindered by the inability of existing sources to selectively transfer information and to rapidly transmit information on the cumulative impacts of many combinations of power plants. This research concerns the development and evaluation of a computerized information system designed to selectively transfer information on both the cumulative and individual impacts of several electric generating facilities located in the southwestern United States. The information system incorporates features of management information systems, environmental information systems, and an issue-oriented system developed at The University of Illinois, making it a hybrid system capable of communicating impact information derived from a variety of sources

  16. The role of computerized diagnostic proposals in the interpretation of the 12-lead electrocardiogram by cardiology and non-cardiology fellows.

    Science.gov (United States)

    Novotny, Tomas; Bond, Raymond; Andrsova, Irena; Koc, Lumir; Sisakova, Martina; Finlay, Dewar; Guldenring, Daniel; Spinar, Jindrich; Malik, Marek

    2017-05-01

    Most contemporary 12-lead electrocardiogram (ECG) devices offer computerized diagnostic proposals. The reliability of these automated diagnoses is limited. It has been suggested that incorrect computer advice can influence physician decision-making. This study analyzed the role of diagnostic proposals in the decision process by a group of fellows of cardiology and other internal medicine subspecialties. A set of 100 clinical 12-lead ECG tracings was selected covering both normal cases and common abnormalities. A team of 15 junior Cardiology Fellows and 15 Non-Cardiology Fellows interpreted the ECGs in 3 phases: without any diagnostic proposal, with a single diagnostic proposal (half of them intentionally incorrect), and with four diagnostic proposals (only one of them being correct) for each ECG. Self-rated confidence of each interpretation was collected. Availability of diagnostic proposals significantly increased the diagnostic accuracy (p<0.001). Nevertheless, in case of a single proposal (either correct or incorrect) the increase of accuracy was present in interpretations with correct diagnostic proposals, while the accuracy was substantially reduced with incorrect proposals. Confidence levels poorly correlated with interpretation scores (rho≈2, p<0.001). Logistic regression showed that an interpreter is most likely to be correct when the ECG offers a correct diagnostic proposal (OR=10.87) or multiple proposals (OR=4.43). Diagnostic proposals affect the diagnostic accuracy of ECG interpretations. The accuracy is significantly influenced especially when a single diagnostic proposal (either correct or incorrect) is provided. The study suggests that the presentation of multiple computerized diagnoses is likely to improve the diagnostic accuracy of interpreters. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The use of diagnostic computerized tomography and radiation therapy in canine and feline hyperadenocorticism

    International Nuclear Information System (INIS)

    Mauldin, G.N.; Burk, R.L.

    1990-01-01

    Therapy for canine pituitary-dependent Cushing's syndrome (PDC) has primarily been medical management with o,p'-DDD. This drug therapy does not directly affect the underlying pituitary pathology, and may have undesirable side effects. Pituitary-dependent Cushing's syndrome may be caused by pituitary microadenomas or macroadenomas. Advances in diagnostic imagery have allowed the antemortem diagnosis of pituitary macrotumors. Treatment of pituitary tumors may be attempted with radiotherapy, especially if a diagnosis of macrotumor can be made before the onset of profound neurologic signs

  18. Clinical performance of dual-source computerized tomography (DSCT) in primary diagnostics of coronary heart diseases

    International Nuclear Information System (INIS)

    Brunner, H.; Froehner, S.; Wagner, M.; Schmitt, R.; Brunn, J.; Gietzen, F.H.; Kerber, S.

    2008-01-01

    Dual-source-CT-technology (DSCT) improves temporal resolution of cardiac computed tomography to 83 ms per heart-phase. In this study, the clinical performance of this new method is evaluated. Materials and Methods: In fifty patients (33 male, 17 female; age 50±13 years) with suspected coronary heart disease, CT angiography (slice thickness 0,75 mm, contrast-agent 60-80 ml iomeprol) was performed with a Somatom Definition scanner. Based on the coronary 15-segment-model of the AHA, scores for image quality and lumen reduction were established to enable the observer, to give recommendations for further therapy. Results: Out of 750 possible AHA-segments, 655 were depicted (87,3%). 591 segments (90,2%) were assessed without any limitation of quality, 49 (7,5%) segments showed moderate, and 15 (2,3%) segments severe limitation in image quality. 508 (77,6%) segments were without pathological findings, 92 (14,0%) segments had minimal atherosclerotic lesions, 42 (6,4%) segments suffered from stenoses with lumen reduction less than 70%, and 13 (2,0%) showed significant stenoses of more than 70%. In 31 patients (62%), coronary heart disease was ruled out by CT angiography without any need for further non-invasive or invasive diagnostics. 8 patients (16%) underwent stress-testing for ischemia. In 11 (22%) patients coronary angiography was recommended, and DSCT findings were confirmed in 10 cases. Only one LCx stenosis was overestimated in DSCT. Conclusion: Contrast-enhanced DSCT is a powerful tool in diagnosis of coronary heart disease. 98% of coronary segments could be assessed in diagnostic quality, and at least 90% of haemodynamically significant coronary stenoses were detected. (orig.)

  19. Method of evaluation of diagnostics reference levels in computerized tomography; Metodo de avaliacao de niveis de referencia de radiodiagnostico em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  20. Cognitive diagnostic assessment via Bayesian evaluation of informative diagnostic hypotheses.

    NARCIS (Netherlands)

    Hoijtink, Herbert; Béland, Sébastien; Vermeulen, Jorine A.

    2014-01-01

    There exist diverse approaches that can be used for cognitive diagnostic assessment, such as mastery testing, constrained latent class analysis, rule space methodology, diagnostic cognitive modeling, and person-fit analysis. Each of these approaches can be used within 1 of the 4 psychometric

  1. Cognitive Diagnostic Assessment via Bayesian Evaluation of Informative Diagnostic Hypotheses

    NARCIS (Netherlands)

    Hoitink, Herbert; Beland, Sebastien; Vermeulen, Jorine

    2014-01-01

    There exist diverse approaches that can be used for cognitive diagnostic assessment, such as mastery testing, constrained latent class analysis, rule space methodology, diagnostic cognitive modeling, and person-fit analysis. Each of these approaches can be used within 1 of the 4 psychometric

  2. The clinical significance of computerized axial tomography (CAT) in consideration of conventional diagnostic methods

    International Nuclear Information System (INIS)

    Huenig, R.

    1976-01-01

    Regarding CAT of the intracranial region, the article informs on a) techniques of examination including the production of normal structures, b) the recognizable pathological changes, c) possibilities of enhancement, d) possibilities of course observation, e) limitations of the methods, as well as on f) risk/benefit aspects g) benefit/cost calculations as compared to conventional methods, and on h) the influence of CAT on the frequency of conventional methods of examination. Regarding CAT of the extracranial region, the information available up to the meeting is reported on. (orig./LH) [de

  3. Assessing a computerized routine health information system in Mali using LQAS.

    Science.gov (United States)

    Stewart, J C; Schroeder, D G; Marsh, D R; Allhasane, S; Kone, D

    2001-09-01

    Between 1987 and 1998 Save the Children conducted a child survival programme in Mali with the goal of reducing maternal and child morbidity and mortality. An integral part of this programme was a computerized demographic surveillance and health information system (HIS) that gathered data on individuals on an on-going basis. To assess the overall coverage and quality of the data in the HIS, to identify specific health districts that needed improvements in data collection methods, and to determine particular areas of weakness in data collection. Random samples of 20 mothers with children LQAS) was used to identify districts in which records and interview results did not meet predetermined levels of acceptability. Data collected in the interviews were combined to estimate overall coverage and quality. When all variables were analyzed, all 14 lots were rejected, and it was estimated that 52% of all events occurring in the community were registered in ProMIS. Much of this poor performance was due to immunization and growth monitoring data, which were not updated due to printer problems. Coverage of events increased (92%) when immunizations and growth monitoring were excluded, and no lots were rejected. When all variables were analyzed for quality of data recorded, six lots were rejected and the overall estimation was 83%. With immunizations and growth monitoring excluded, overall quality was 86% and no lots were rejected. The comprehensive computerized HIS did not meet expectations. This may be due, in part, to the ambitious objective of complete and intensive monitoring of a large population without adequate staff and equipment. Future efforts should consider employing a more targeted and streamlined HIS so that data can be more complete and useful.

  4. Computerized map-based information management system for natural resource management

    Energy Technology Data Exchange (ETDEWEB)

    Miller, K.

    1995-12-01

    Federal agencies, states and resource managers have control and stewardship responsibility over a significant inventory of natural resources. A number of federal regulations require the review, protection and preservation of natural resource protection. Examples of such actions include the reauthorization of the Clean Water Act and the modification of the National Contingency Plan to incorporate the requirements of the Oil Pollution Act of 1990. To successfully preserve conserve and restore natural resources on federal reservations, and state and private lands, and to comply with Federal regulations designed to protect natural resources located on their sites, and the type of information on these resources required by environmental regulations. This paper presents an approach using a computerized, graphical information management system to catalogue and track data for the management of natural resources under Federal and state regulations, and for promoting resource conservation, preservation and restoration. The system is designed for use by Federal facility resource managers both for the day-to-day management of resources under their control, and for the longer-term management of larger initiatives, including restoration of significant or endangered resources, participation in regional stewardship efforts, and general ecosystem management. The system will be valuable for conducting natural resource baseline inventories an implementing resource management plans on lands other than those controlled by the Federal government as well. The system can provide a method for coordinating the type of natural resource information required by major federal environmental regulations--thereby providing a cost-effective means for managing natural resource information.

  5. The effects of mild and severe traumatic brain injury on speed of information processing as measured by the computerized tests of information processing (CTIP).

    Science.gov (United States)

    Tombaugh, Tom N; Rees, Laura; Stormer, Peter; Harrison, Allyson G; Smith, Andra

    2007-01-01

    In spite of the fact that reaction time (RT) measures are sensitive to the effects of traumatic brain injury (TBI), few RT procedures have been developed for use in standard clinical evaluations. The computerized test of information processing (CTIP) [Tombaugh, T. N., & Rees, L. (2000). Manual for the computerized tests of information processing (CTIP). Ottawa, Ont.: Carleton University] was designed to measure the degree to which TBI decreases the speed at which information is processed. The CTIP consists of three computerized programs that progressively increase the amount of information that is processed. Results of the current study demonstrated that RT increased as the difficulty of the CTIP tests increased (known as the complexity effect), and as severity of injury increased (from mild to severe TBI). The current study also demonstrated the importance of selecting a non-biased measure of variability. Overall, findings suggest that the CTIP is an easy to administer and sensitive measure of information processing speed.

  6. Key diagnostic information for the oncologist

    International Nuclear Information System (INIS)

    Zlatareva, D.

    2012-01-01

    Full text: The radiologists use many modalities for imaging of oncologic patients. In order to get the most out of these imaging studies oncologist have to provide with precise information: what is the working diagnosis, what treatment the patients has had and what is the clinical question should be answered by imaging study. The main indications for imaging are confirmation of diagnosis, evaluation of the patient for surgery or assessment of response to the therapy. These will influence the choice of the test, the protocol and interpretation of the results. Imaging plays a vital role in the management of patients with cancer. It is important not only for diagnosis, indicating sites of abnormality, and guiding biopsies, but it is also crucial in assessing disease extent and thereby determining treatment. The stage of cancer at the time of diagnosis is a key factor to define prognosis and is important element in determining appropriate treatment. The most clinically used cancer staging system is tumor node metastasis (TNM). Stage is determined from information on the tumor, regional nodes, and metastases and by grouping cases with similar prognosis. The criteria for defining anatomic extent of disease are specific for tumors at different anatomic sites and of different histologic types. Therefore, the criteria for T, N and M are defined separately for each tumor and histologic type. For Hodgkin and other lymphomas, a different system for the extent of disease and prognosis is used. It is mandatory for the radiologist to learn TNM system to provide the oncologist with key diagnostic information. Learning objectives: To understand TNM staging system for the most common malignancies To review the changes from the sixth to the seven edition of the American Joint committee on cancer staging manual To describe diagnostic information provided by CT and MRI in preoperative planning and after therapy To discuss the role of PET/CT imaging in oncology

  7. Information security risk management for computerized health information systems in hospitals: a case study of Iran

    OpenAIRE

    Zarei, Javad; Sadoughi, Farahnaz

    2016-01-01

    Javad Zarei,1 Farahnaz Sadoughi2 1Health Information Management, Health Management and Economics Research Center, School of Health Management and Information Science, Iran University of Medical Sciences, Tehran, Islamic Republic of Iran, 2Health Information Management Department, School of Health Management and Information Science, Iran University of Medical Sciences, Tehran, Islamic Republic of Iran Background: In recent years, hospitals in Iran – similar to those in other...

  8. Design and validation of a questionnaire to evaluate the usability of computerized critical care information systems.

    Science.gov (United States)

    von Dincklage, Falk; Lichtner, Gregor; Suchodolski, Klaudiusz; Ragaller, Maximilian; Friesdorf, Wolfgang; Podtschaske, Beatrice

    2017-08-01

    The implementation of computerized critical care information systems (CCIS) can improve the quality of clinical care and staff satisfaction, but also holds risks of disrupting the workflow with consecutive negative impacts. The usability of CCIS is one of the key factors determining their benefits and weaknesses. However, no tailored instrument exists to measure the usability of such systems. Therefore, the aim of this study was to design and validate a questionnaire that measures the usability of CCIS. Following a mixed-method design approach, we developed a questionnaire comprising two evaluation models to assess the usability of CCIS: (1) the task-specific model rates the usability individually for several tasks which CCIS could support and which we derived by analyzing work processes in the ICU; (2) the characteristic-specific model rates the different aspects of the usability, as defined by the international standard "ergonomics of human-system interaction". We tested validity and reliability of the digital version of the questionnaire in a sample population. In the sample population of 535 participants both usability evaluation models showed a strong correlation with the overall rating of the system (multiple correlation coefficients ≥0.80) as well as a very high internal consistency (Cronbach's alpha ≥0.93). The novel questionnaire is a valid and reliable instrument to measure the usability of CCIS and can be used to study the influence of the usability on their implementation benefits and weaknesses.

  9. A formal design verification and validation on the human factors of a computerized information system in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Yong Hee; Park, Jae Chang; Cheon, Se Woo; Jung, Kwang Tae; Baek, Seung Min; Han, Seung; Park, Hee Suk; Son, Ki Chang; Kim, Jung Man; Jung Yung Woo

    1999-11-01

    This report describe a technical transfer under the title of ''A formal design verification and validation on the human factors of a computerized information system in nuclear power plants''. Human factors requirements for the information system designs are extracted from various regulatory and industrial standards and guidelines, and interpreted into a more specific procedures and checklists for verifying the satisfaction of those requirements. A formalized implementation plan is established for human factors verification and validation of a computerized information system in nuclear power plants. Additionally, a Computer support system, named as DIMS-web (design Issue Management System), is developed based upon web internet environment so as to enhance the implementation of the human factors activities. DIMS-Web has three maine functions: supporting requirements review, tracking design issues, and management if issues screening evaluation. DIMS-Web shows its benefits in practice through a trial application to the design review of CFMS for YGN nuclear unit 5 and 6. (author)

  10. Investigation of the Usability of Computerized Critical Care Information Systems in Germany.

    Science.gov (United States)

    von Dincklage, Falk; Suchodolski, Klaudiusz; Lichtner, Gregor; Friesdorf, Wolfgang; Podtschaske, Beatrice; Ragaller, Maximilian

    2017-01-01

    The term "usability" describes how effectively, efficiently, and with what level of user satisfaction an information system can be used to accomplish specific goals. Computerized critical care information systems (CCISs) with high usability increase quality of care and staff satisfaction, while reducing medication errors. Conversely, systems lacking usability can interrupt clinical workflow, facilitate errors, and increase charting time. The aim of this study was to investigate and compare usability across CCIS currently used in Germany. In this study, German intensive care unit (ICU) nurses and physicians completed a specialized, previously validated, web-based questionnaire. The questionnaire assessed CCIS usability based on three rating models: an overall rating of the systems, a model rating technical usability, and a model rating task-specific usability. We analyzed results from 535 survey participants and compared eight different CCIS commonly used in Germany. Our results showed that usability strongly differs across the compared systems. The system ICUData had the best overall rating and technical usability, followed by the platforms ICM and MetaVision. The same three systems performed best in the rating of task-specific usability without significant differences between each other. Across all systems, overall ratings were more dependent on ease-of-use aspects than on aspects of utility/functionality, and the general scope of the functions offered was rated better than how well the functions are realized. Our results suggest that manufacturers should shift some of their effort away from the development of new features and focus more on improving the ease-of-use and quality of existing features.

  11. Post transplant urinary tract infection in Autosomal dominant polycystic kidney disease a perpetual diagnostic dilema - 18-fluorodeoxyglucose - Positron emission computerized tomography - A valuable tool

    International Nuclear Information System (INIS)

    Sainaresh, VV; Jain, SH; Patel, HV; Shah, PR; Vanikar, AV; Trivedi, HL

    2011-01-01

    Urinary tract infection (UTI) is the most common infection contracted by renal allograft recipients. In patients of autosomal dominant polycystic kidney disease (ADPKD), cyst infection presents a complex diagnostic and therapeutic challenge especially in the post transplant period. Accurate diagnosis forms the cornerstone in salvaging the graft from potentially catastrophic outcome. We describe a case of xanthogranulomatous pyelonephritis (XPN) in the native kidney in a patient of post transplant ADPKD which presented as frequently relapsing UTI with graft dysfunction where in accurate diagnosis was made possible with the aid of 18-fluorodeoxyglucose (FDG) - Positron emission computerized tomography (PET/CT)

  12. Joint two-view information for computerized detection of microcalcifications on mammograms

    International Nuclear Information System (INIS)

    Sahiner, Berkman; Chan, H.-P.; Hadjiiski, Lubomir M.; Helvie, Mark A.; Paramagul, Chinatana; Ge Jun; Wei Jun; Zhou Chuan

    2006-01-01

    We are developing new techniques to improve the accuracy of computerized microcalcification detection by using the joint two-view information on craniocaudal (CC) and mediolateral-oblique (MLO) views. After cluster candidates were detected using a single-view detection technique, candidates on CC and MLO views were paired using their radial distances from the nipple. Candidate pairs were classified with a similarity classifier that used the joint information from both views. Each cluster candidate was also characterized by its single-view features. The outputs of the similarity classifier and the single-view classifier were fused and the cluster candidate was classified as a true microcalcification cluster or a false-positive (FP) using the fused two-view information. A data set of 116 pairs of mammograms containing microcalcification clusters and 203 pairs of normal images from the University of South Florida (USF) public database was used for training the two-view detection algorithm. The trained method was tested on an independent test set of 167 pairs of mammograms, which contained 71 normal pairs and 96 pairs with microcalcification clusters collected at the University of Michigan (UM). The similarity classifier had a very low FP rate for the test set at low and medium levels of sensitivity. However, the highest mammogram-based sensitivity that could be reached by the similarity classifier was 69%. The single-view classifier had a higher FP rate compared to the similarity classifier, but it could reach a maximum mammogram-based sensitivity of 93%. The fusion method combined the scores of these two classifiers so that the number of FPs was substantially reduced at relatively low and medium sensitivities, and a relatively high maximum sensitivity was maintained. For the malignant microcalcification clusters, at a mammogram-based sensitivity of 80%, the FP rates were 0.18 and 0.35 with the two-view fusion and single-view detection methods, respectively. When the

  13. Computerized tomography

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the design of computerized tomographic X-ray equipment are described which lead to improvements in the mechanical properties, speed and size of scanning areas. The method envisages the body being scanned as a two-dimensional matrix of elements arising from a plurality of concentric rings. The concentric centre need not coincide with the axis of rotation. The procedures for rotation of the X-ray beam and detectors around the patient and for translating the measured information into attenuation coefficients for each matrix element of the body are described in detail. Explicit derivations are given for the mathematical formulae used. (U.K.)

  14. [Introduction of computerized anesthesia-recording systems and construction of comprehensive medical information network for patients undergoing surgery in the University of Tokyo Hospital].

    Science.gov (United States)

    Kitamura, Takayuki; Hoshimoto, Hiroyuki; Yamada, Yoshitsugu

    2009-10-01

    The computerized anesthesia-recording systems are expensive and the introduction of the systems takes time and requires huge effort. Generally speaking, the efficacy of the computerized anesthesia-recording systems on the anesthetic managements is focused on the ability to automatically input data from the monitors to the anesthetic records, and tends to be underestimated. However, once the computerized anesthesia-recording systems are integrated into the medical information network, several features, which definitely contribute to improve the quality of the anesthetic management, can be developed; for example, to prevent misidentification of patients, to prevent mistakes related to blood transfusion, and to protect patients' personal information. Here we describe our experiences of the introduction of the computerized anesthesia-recording systems and the construction of the comprehensive medical information network for patients undergoing surgery in The University of Tokyo Hospital. We also discuss possible efficacy of the comprehensive medical information network for patients during surgery under anesthetic managements.

  15. Computerized systems for high level information processing and decision making in the field of PSA

    International Nuclear Information System (INIS)

    Kafka, P.; Kunitz, H.

    1990-01-01

    A comprehensive review of Probabilistic Safety Assessment (PSA) related program packages is made. Three fields in methodological succession are covered: plant modeling, data quantification procedures and decision-making support. Packages for fault tree construction and minimal cut sets evaluation are referred to and the performances of three of them: RALLY, ORCHARD and SALP-PC, are discussed and compared. Notions on the raw data sources are presented and the Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is given as an example for data base management system generating PSA data. Aggregated risk models for support in safety assessment, plant operation and accident management (SARA, ESSM, PRISIM) are cited. Examples of systems supporting 'living PSA' (SAIS, SUPER-NET, LESSEPS 1300, NUPRA, SPSA) are given. The concluding remarks outline the state-of-the-art developments of computerized systems for reliability analyses. 1 fig., 1 tab., 51 refs. (R.Ts)

  16. [Computerization and the importance of information in health system, as in health care resources registry].

    Science.gov (United States)

    Troselj, Mario; Fanton, Davor

    2005-01-01

    The possibilities of creating a health care resources registry and its operating in Croatia as well as the importance of information in health system are described. At the Croatian Institute of Public Health, monitoring of human resources is performed through the national Health Workers Registry. It also covers basic data on all health units, bed capacities of health facilities included. The initiated health care computerization has urged the idea of forming one more database on physical resources, i.e. on registered medical devices and equipment, more complete. Linking these databases on health resources would produce a single Health Care Resources Registry. The concept views Health Care Resources Registry as part of the overall health information system with centralized information on the health system. The planned development of segments of a single health information system is based on the implementation of the accepted international standards and common network services. Network services that are based on verified Internet technologies are used within a safe, reliable and closed health computer network, which makes up the health intranet (WAN--Wide Area Network). The resource registry is a software solution based on the relational database that monitors history, thus permitting the data collected over a longer period to be analyzed. Such a solution assumes the existence of a directory service, which would replace the current independent software for the Health Workers Registry. In the Health Care Resources Registry, the basic data set encompasses data objects and attributes from the directory service. The directory service is compatible with the LDAP protocol (Lightweight Directory Access Protocol), providing services uniformly to the current records on human and physical resources. Through the storage of attributes defined according to the HL7 (Health Level Seven) standard, directory service is accessible to all applications of the health information system

  17. Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: Validation on a physical dynamic cardiac phantom

    International Nuclear Information System (INIS)

    King, Martin; Rodgers, Zachary; Giger, Maryellen L.; Bardo, Dianna M. E.; Patel, Amit R.

    2010-01-01

    Purpose: In cardiac computed tomography (CT), important clinical indices, such as the coronary calcium score and the percentage of coronary artery stenosis, are often adversely affected by motion artifacts. As a result, the expert observer must decide whether or not to use these indices during image interpretation. Computerized methods potentially can be used to assist in these decisions. In a previous study, an artificial neural network (ANN) regression model provided assessability (image quality) indices of calcified plaque images from the software NCAT phantom that were highly agreeable with those provided by expert observers. The method predicted assessability indices based on computer-extracted features of the plaque. In the current study, the ANN-predicted assessability indices were used to identify calcified plaque images with diagnostic calcium scores (based on mass) from a physical dynamic cardiac phantom. The basic assumption was that better quality images were associated with more accurate calcium scores. Methods: A 64-channel CT scanner was used to obtain 500 calcified plaque images from a physical dynamic cardiac phantom at different heart rates, cardiac phases, and plaque locations. Two expert observers independently provided separate sets of assessability indices for each of these images. Separate sets of ANN-predicted assessability indices tailored to each observer were then generated within the framework of a bootstrap resampling scheme. For each resampling iteration, the absolute calcium score error between the calcium scores of the motion-contaminated plaque image and its corresponding stationary image served as the ground truth in terms of indicating images with diagnostic calcium scores. The performances of the ANN-predicted and observer-assigned indices in identifying images with diagnostic calcium scores were then evaluated using ROC analysis. Results: Assessability indices provided by the first observer and the corresponding ANN performed

  18. Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: Validation on a physical dynamic cardiac phantom

    Energy Technology Data Exchange (ETDEWEB)

    King, Martin; Rodgers, Zachary; Giger, Maryellen L.; Bardo, Dianna M. E.; Patel, Amit R. [Department of Radiology, Committee on Medical Physics, University of Chicago, 5841 South Maryland Avenue, MC 2026, Chicago, Illinois 60637 (United States); Department of Diagnostic Radiology, Oregon Health and Science University, 3181 Southwest Sam Jackson Park Road, Portland, Oregon 97239 (United States); Department of Medicine, University of Chicago, 5841 South Maryland Avenue, MC 5084, Chicago, Illinois 60637 (United States)

    2010-11-15

    Purpose: In cardiac computed tomography (CT), important clinical indices, such as the coronary calcium score and the percentage of coronary artery stenosis, are often adversely affected by motion artifacts. As a result, the expert observer must decide whether or not to use these indices during image interpretation. Computerized methods potentially can be used to assist in these decisions. In a previous study, an artificial neural network (ANN) regression model provided assessability (image quality) indices of calcified plaque images from the software NCAT phantom that were highly agreeable with those provided by expert observers. The method predicted assessability indices based on computer-extracted features of the plaque. In the current study, the ANN-predicted assessability indices were used to identify calcified plaque images with diagnostic calcium scores (based on mass) from a physical dynamic cardiac phantom. The basic assumption was that better quality images were associated with more accurate calcium scores. Methods: A 64-channel CT scanner was used to obtain 500 calcified plaque images from a physical dynamic cardiac phantom at different heart rates, cardiac phases, and plaque locations. Two expert observers independently provided separate sets of assessability indices for each of these images. Separate sets of ANN-predicted assessability indices tailored to each observer were then generated within the framework of a bootstrap resampling scheme. For each resampling iteration, the absolute calcium score error between the calcium scores of the motion-contaminated plaque image and its corresponding stationary image served as the ground truth in terms of indicating images with diagnostic calcium scores. The performances of the ANN-predicted and observer-assigned indices in identifying images with diagnostic calcium scores were then evaluated using ROC analysis. Results: Assessability indices provided by the first observer and the corresponding ANN performed

  19. A formal design verification and validation on the human factors of a computerized information system in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Park, Jae Chang; Cheon, Se Woo; Jung, Kwang Tae; Baek, Seung Min; Han, Seung; Park, Hee Suk; Son, Ki Chang; Kim, Jung Man; Jung Yung Woo

    1999-11-01

    This report describe a technical transfer under the title of ''A formal design verification and validation on the human factors of a computerized information system in nuclear power plants''. Human factors requirements for the information system designs are extracted from various regulatory and industrial standards and guidelines, and interpreted into a more specific procedures and checklists for verifying the satisfaction of those requirements. A formalized implementation plan is established for human factors verification and validation of a computerized information system in nuclear power plants. Additionally, a Computer support system, named as DIMS-web (design Issue Management System), is developed based upon web internet environment so as to enhance the implementation of the human factors activities. DIMS-Web has three maine functions: supporting requirements review, tracking design issues, and management if issues screening evaluation. DIMS-Web shows its benefits in practice through a trial application to the design review of CFMS for YGN nuclear unit 5 and 6. (author)

  20. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    Science.gov (United States)

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  1. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  2. Accessing leaking underground storage tank case studies and publications through the EPA's Computerized On-Line Information System (COLIS)

    International Nuclear Information System (INIS)

    Hillger, R.; Tibay, P.

    1991-01-01

    The US EPA's regulations for underground storage tanks (USTs) require corrective action to be taken in response to leaking USTs. Recent developments of UST programs nationwide as well as the introduction of new technologies to clean up UST sites have increased the diversity of experience levels among personnel involved with this type of work. The EPA's Computerized On-Line Information System (COLIS) has been developed to facilitate technology transfer among the personnel involved in UST cleanup. The system allows for the quick and simple retrieval of data relating to UST incidents, as well as other hazardous waste-related information. The system has been used by response personnel at all levels of government, academia, and private industry. Although it has been in existence for many years, users are just now realizing the potential wealth of information stored in this system. COLIS access can be accomplished via telephone lines utilizing a personal computer and a modem

  3. Ordering of diagnostic information in encoded medical images. Accuracy progression

    Science.gov (United States)

    Przelaskowski, A.; Jóźwiak, R.; Krzyżewski, T.; Wróblewska, A.

    2008-03-01

    A concept of diagnostic accuracy progression for embedded coding of medical images was presented. Implementation of JPEG2000 encoder with a modified PCRD optimization algorithm was realized and initially verified as a tool for accurate medical image streaming. Mean square error as a distortion measure was replaced by other numerical measures to revise quality progression according to diagnostic importance of successively encoded image information. A faster increment of image diagnostic importance during reconstruction of initial packets of code stream was reached. Modified Jasper code was initially tested on a set of mammograms containing clusters of microcalcifications and malignant masses, and other radiograms. Teleradiologic applications were considered as the first area of interests.

  4. Diagnostics of communication and information environment of pedagogical program means

    Directory of Open Access Journals (Sweden)

    Елена Вадимовна Журавлёва

    2010-06-01

    Full Text Available The efficiency of pedagogical program means is considered through the correctness of a communication and information environment organization. The totality of pedagogical conditions is adduced; the communication and information environment answers these conditions. The main directions (didactic, psychological, ergonomic of analysis are determined and the methods choice for their diagnostics is grounded.

  5. Development of a Diagnostic System for Information Ethics Education

    Science.gov (United States)

    Shiota, Shingo; Sakai, Kyohei; Kobayashi, Keita

    2016-01-01

    This paper presents a new diagnostic system for information ethics education. In order to educate children about information ethics, it is necessary to know the stage at which they currently are in terms of their knowledge of the same. Some actual condition surveys have been conducted by the Cabinet Office and the National Police Agency to gauge…

  6. Information sharing during diagnostic assessments: what is relevant for parents?

    Science.gov (United States)

    Klein, Sheryl; Wynn, Kerry; Ray, Lynne; Demeriez, Lori; LaBerge, Patricia; Pei, Jacqueline; St Pierre, Cherie

    2011-05-01

    ABSTRACT This descriptive qualitative study facilitates the application of family-centered care within a tertiary care interdisciplinary neurodevelopmental diagnostic assessment clinic by furthering an understanding of parent perceptions of the relevance of diagnostic information provision. An interdisciplinary assessment team completed an open-ended questionnaire to describe parent information provision. Parents from 9 families completed in-depth parent interviews following clinic attendance to discuss perceptions of information received. Interviews were audiotaped, transcribed, and coded by related themes. Parents did not perceive the information in the way professionals expected. Parents acknowledged receipt of comprehensive information relevant to the diagnosis but indicated that not all their needs were met. During the interviews, parents described the assessment process, preassessment information, and "steps in their journey." They noted that a strength-based approach and a focus on parental competency would support their coping efforts. Results underscore the need for professionals to be attentive to parents' individualized needs.

  7. Social emotional information processing in adults: Development and psychometrics of a computerized video assessment in healthy controls and aggressive individuals.

    Science.gov (United States)

    Coccaro, Emil F; Fanning, Jennifer R; Fisher, Eliana; Couture, Laurel; Lee, Royce J

    2017-02-01

    A computerized version of an assessment of Social-Emotional Information Processing (SEIP) using audio-video film stimuli instead of written narrative vignettes was developed for use in adult participants. This task allows for an assessment of encoding or relevant/irrelevant social-emotional information, attribution bias, and endorsement of appropriate, physically aggressive, and relationally aggressive responses to aversive social-emotional stimuli. The psychometric properties of this Video-SEIP (V-SEIP) assessment were examined in 75 healthy controls (HC) and in 75 individuals with DSM-5 Intermittent Explosive Disorder (IED) and were also compared with the original questionnaire (SEIP-Q) version of the task (HC=26; IED=26). Internal consistency, inter-rater reliability, and test-retest properties of the V-SEIP were good to excellent. In addition, IED participants displayed reduced encoding of relevant information from the film clips, elevated hostile attribution bias, elevated negative emotional response, and elevated endorsement of physically aggressive and relationally aggressive responses to the ambiguous social-emotional stimuli presented in the V-SEIP. These data indicate that the V-SEIP represents a valid and comprehensive alternative to the paper-and-pencil assessment of social-emotional information processing biases in adults. Copyright © 2016. Published by Elsevier B.V.

  8. Technologies in computerized lexicography | Kruyt | Lexikos

    African Journals Online (AJOL)

    Although the topic of this paper is technology, focus is on functional rather than technical aspects of computerized lexicography. Keywords: computerized lexicography, electronic dictionary, electronic text corpus, lexicographer's workbench, integrated language database, automatic linguistic analysis, information retrieval, ...

  9. Computerized adaptive testing item selection in computerized adaptive learning systems

    NARCIS (Netherlands)

    Eggen, Theodorus Johannes Hendrikus Maria; Eggen, T.J.H.M.; Veldkamp, B.P.

    2012-01-01

    Item selection methods traditionally developed for computerized adaptive testing (CAT) are explored for their usefulness in item-based computerized adaptive learning (CAL) systems. While in CAT Fisher information-based selection is optimal, for recovering learning populations in CAL systems item

  10. A novel class of laboratory middleware. Promoting information flow and improving computerized provider order entry.

    Science.gov (United States)

    Grisson, Ricky; Kim, Ji Yeon; Brodsky, Victor; Kamis, Irina K; Singh, Balaji; Belkziz, Sidi M; Batra, Shalini; Myers, Harold J; Demyanov, Alexander; Dighe, Anand S

    2010-06-01

    A central duty of the laboratory is to inform clinicians about the availability and usefulness of laboratory testing. In this report, we describe a new class of laboratory middleware that connects the traditional clinical laboratory information system with the rest of the enterprise, facilitating information flow about testing services. We demonstrate the value of this approach in efficiently supporting an inpatient order entry application. We also show that order entry monitoring and iterative middleware updates can enhance ordering efficiency and promote improved ordering practices. Furthermore, we demonstrate the value of algorithmic approaches to improve the accuracy and completeness of laboratory test searches. We conclude with a discussion of design recommendations for middleware applications and discuss the potential role of middleware as a sharable, centralized repository of laboratory test information.

  11. The effect of information types on diagnostic strategies in the information aid

    International Nuclear Information System (INIS)

    Kim, Jong Hyun; Seong, Poong Hyun

    2007-01-01

    Through experiments, this paper investigates the compatibility of information types with the diagnostic strategy in information aid. Compatibility with operator strategies is an important requirement for information aiding systems in nuclear power plants (NPPs). This paper used three typical types of information aids for MCR operators to investigate the effect of the aids on diagnostic strategies: 'alarm (A),' 'hypothesis on faults (H),' and 'hypothesis on faults and expected symptoms (HS).' The experimental results indicate that the effectiveness of information aid types can vary, dependent on the strategies subjects employ. The results also show that the HS aid improved the diagnosis performance in the hypothesis-and-test strategy

  12. Physicians' Perceptions on the usefulness of contextual information for prioritizing and presenting alerts in computerized physician order entry systems

    Directory of Open Access Journals (Sweden)

    Jung Martin

    2012-10-01

    Full Text Available Abstract Background One possible approach towards avoiding alert overload and alert fatigue in Computerized Physician Order Entry (CPOE systems is to tailor their drug safety alerts to the context of the clinical situation. Our objective was to identify the perceptions of physicians on the usefulness of clinical context information for prioritizing and presenting drug safety alerts. Methods We performed a questionnaire survey, inquiring CPOE-using physicians from four hospitals in four European countries to estimate the usefulness of 20 possible context factors. Results The 223 participants identified the ‘severity of the effect’ and the ‘clinical status of the patient’ as the most useful context factors. Further important factors are the ‘complexity of the case’ and the ‘risk factors of the patient’. Conclusions Our findings confirm the results of a prior, comparable survey inquiring CPOE researchers. Further research should focus on implementing these context factors in CPOE systems and on subsequently evaluating their impact.

  13. 76 FR 2144 - Quest Diagnostics, Inc. Information Technology Help Desk Services Including On-Site Leased...

    Science.gov (United States)

    2011-01-12

    .... Information Technology Help Desk Services Including On-Site Leased Workers From Modis, West Norriton, PA..., applicable to workers of Quest Diagnostics, Inc., Information Technology Help Desk Services, West Norriton... Quest Diagnostics, Inc., Information Technology Help Desk [[Page 2145

  14. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  15. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  16. Disclosure of computerized health care information: provider privacy rights under supply side competition.

    Science.gov (United States)

    Watson, B L

    1981-01-01

    This Article explores the constitutional, statutory and common law privacy rights of physicians given the inescapable role of delivery data under supply side competition. The Article begins with a general review of the federal constitutional right of privacy. It then discusses the statutory protection given to physician-specific data under current federal law, and considers the insights gained from the controversy over physician data and the federal Freedom of Information Act. The remainder of the Article analyzes the usefulness of several common law causes of action to remedy the misuse of physician data, and concludes with recommendations which may obviate the need for litigation to protect against misuse of physician-specific data.

  17. Diagnostic Reasoning using Prognostic Information for Unmanned Aerial Systems

    Science.gov (United States)

    Schumann, Johann; Roychoudhury, Indranil; Kulkarni, Chetan

    2015-01-01

    With increasing popularity of unmanned aircraft, continuous monitoring of their systems, software, and health status is becoming more and more important to ensure safe, correct, and efficient operation and fulfillment of missions. The paper presents integration of prognosis models and prognostic information with the R2U2 (REALIZABLE, RESPONSIVE, and UNOBTRUSIVE Unit) monitoring and diagnosis framework. This integration makes available statistically reliable health information predictions of the future at a much earlier time to enable autonomous decision making. The prognostic information can be used in the R2U2 model to improve diagnostic accuracy and enable decisions to be made at the present time to deal with events in the future. This will be an advancement over the current state of the art, where temporal logic observers can only do such valuation at the end of the time interval. Usefulness and effectiveness of this integrated diagnostics and prognostics framework was demonstrated using simulation experiments with the NASA Dragon Eye electric unmanned aircraft.

  18. Clinical neuroanatomy and diagnostic imaging of the skull. Computerized tomography and nmr imaging. 2. rev. and enlarged ed. Klinische Neuroanatomie und kranielle Bilddiagnostik. Computertomographie und Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Kretschmann, H.J. (Medizinische Hochschule Hannover (Germany). Abt. Neuroanatomie); Weinrich, W. (Krankenhaus Nordstadt, Hannover (Germany). Neurologische Klinik)

    1991-01-01

    In the last few years, the techniques of CT, MRI, PET and utrasonography have been improved in their diagnostic efficiency, but in spite of the much enhanced resolution achievable with the new techniques, a large part of the neurofunctional systems that are of great significance to clinical diagnostic evaluation remains in the dark. The local structure of the neurofunctional systems is derived from the data describing the position of the conductive structures such as cerebral ventricles or typical cerebral sulci or gyri. A good knowledge of the three-dimensional topography of the neuroanatomy in the skull is required for this purpose, and this is what the book at hand is intended to confer. The arteries and their vascular environment are shown in the frontal, sagittal and axial plane and are compared with drawings produced from angiographies. The information given covers the cranium viscerale, the craniocervical neighbouring areas, and the motor innervation areas of the skull. The term 'diagnostic imaging of the skull' comprises the whole head and the transitional zones. The illustration of the neurofunctional system anatomy in the tomogram presented in this book is a source of information that may serve as a guide for pathfinding in CT, MRI, PET and ultrasonography. In addition, the knowledge found in the book will help to assign clinical data to pathologic findings revealed by CT or MRI. (orig.) With 596 mostly coloured figs.

  19. Dosimetry of computerized tomography in the evaluation of hip dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Guyer, B.; Bassano, D.A.; Levinsohn, E.M.; Smith, D.S.; Cady, R.B.

    1984-07-01

    The usefulness of computerized tomography (CT) in the assessment of hip dysplasia has recently been given attention in the literature and concern regarding radiation dose has been raised. This study was undertaken to measure the radiation dose, both in and out of plaster, for plain films, arthrography, tomography, and CT. A method is suggested to reduce dosage by 80% without compromising diagnostic information. Our experience with 25 scans of patients aged 4 months to 39 years is presented.

  20. X-ray computerized tomography based on the method of reciprocal projection with filtration by double differentiation. Procedure and information peculiarities

    International Nuclear Information System (INIS)

    Vajnberg, Eh.I.; Kazak, I.A.; Fajngojz, M.L.

    1985-01-01

    The results of experimental evaluation of procedure and information peculiarities of the method of reciprocal projection with filtration of projections by double differentiation (RPFDD) for the monitoring of industrial products are generalized. Succession of stages n the RPFDD method permits to separately optimize reconstruction of high-frequeny and low-frequency tomogram structure which sharply reduces the acuteness of contradictions of conventional scheme between the required increase of accuracy and intolerable growth of computerized charges. High accuracy of evaluation of the linear attenuation factor of low-frequency structures in a wide range of densities at the last stage of RPFDD scheme is attained despite the non-conventionally small range of values at earlier stages of computerized processing

  1. Computerized extraction of information on the quality of diabetes care from free text in electronic patient records of general practitioners

    NARCIS (Netherlands)

    Voorham, Jaco; Denig, Petra

    2007-01-01

    Objective: This study evaluated a computerized method for extracting numeric clinical measurements related to diabetes care from free text in electronic patient records (EPR) of general practitioners. Design and Measurements: Accuracy of this number-oriented approach was compared to manual chart

  2. Physicians' Perceptions on the usefulness of contextual information for prioritizing and presenting alerts in computerized physician order entry systems

    NARCIS (Netherlands)

    Jung, Martin; Riedmann, Daniel; Hackl, Werner O.; Hoerbst, Alexander; Jaspers, Monique W.; Ferret, Laurie; Lawton, Kitta; Ammenwerth, Elske

    2012-01-01

    Background: One possible approach towards avoiding alert overload and alert fatigue in Computerized Physician Order Entry (CPOE) systems is to tailor their drug safety alerts to the context of the clinical situation. Our objective was to identify the perceptions of physicians on the usefulness of

  3. The 10/66 Dementia Research Group's fully operationalised DSM-IV dementia computerized diagnostic algorithm, compared with the 10/66 dementia algorithm and a clinician diagnosis: a population validation study

    Directory of Open Access Journals (Sweden)

    Krishnamoorthy ES

    2008-06-01

    Full Text Available Abstract Background The criterion for dementia implicit in DSM-IV is widely used in research but not fully operationalised. The 10/66 Dementia Research Group sought to do this using assessments from their one phase dementia diagnostic research interview, and to validate the resulting algorithm in a population-based study in Cuba. Methods The criterion was operationalised as a computerised algorithm, applying clinical principles, based upon the 10/66 cognitive tests, clinical interview and informant reports; the Community Screening Instrument for Dementia, the CERAD 10 word list learning and animal naming tests, the Geriatric Mental State, and the History and Aetiology Schedule – Dementia Diagnosis and Subtype. This was validated in Cuba against a local clinician DSM-IV diagnosis and the 10/66 dementia diagnosis (originally calibrated probabilistically against clinician DSM-IV diagnoses in the 10/66 pilot study. Results The DSM-IV sub-criteria were plausibly distributed among clinically diagnosed dementia cases and controls. The clinician diagnoses agreed better with 10/66 dementia diagnosis than with the more conservative computerized DSM-IV algorithm. The DSM-IV algorithm was particularly likely to miss less severe dementia cases. Those with a 10/66 dementia diagnosis who did not meet the DSM-IV criterion were less cognitively and functionally impaired compared with the DSMIV confirmed cases, but still grossly impaired compared with those free of dementia. Conclusion The DSM-IV criterion, strictly applied, defines a narrow category of unambiguous dementia characterized by marked impairment. It may be specific but incompletely sensitive to clinically relevant cases. The 10/66 dementia diagnosis defines a broader category that may be more sensitive, identifying genuine cases beyond those defined by our DSM-IV algorithm, with relevance to the estimation of the population burden of this disorder.

  4. Staging of bronchogenic carcinoma by computerized tomography

    International Nuclear Information System (INIS)

    Sommer, B.; Bauer, W.M.; Rath, M.; Fenzl, G.; Stelter, W.J.; Lissner, J.

    1981-01-01

    It was possible to check the information obtained by CT scanning in 36 patients out of 49 who had been subjected to computerized tomography, in respect of the extension of the primary tumour (T stage), and in 25 patients in respect of the degree of mediastinal lymphatic node involvement (N stage). In all 49 patients, the presence of bronchogenic carcinoma had been safely established. In 97% of the cases, assessment of the extension of the primary tumour was found to be correct. Assessment of the N stage, however, is more problematic, since detection of mediastinal lymphatic nodes by computerized tomography does not necessarily tell us something about their metastatic involvement. If all recognizable lymphatic nodes are interpreted as potential metastases, we have no false negative but 61% false positive results because of the frequency of postinflammatory or anthracotic lymphatic nodes. In case of exclusive assessment of lymphatic node enlargement above 1 cm diameter, the rate of metastatic nodes increases considerably (83%). Computerized tomography is definitely superior to all roentgenological methods in assessing the stage of a bronchogenic carcinoma; hence, it could occupy a key position in determining the diagnostic and therapeutic approach in patients with this disease. (orig.) [de

  5. Development of an instrument to measure health center (HC) personnel's computer use, knowledge and functionality demand for HC computerized information system in Thailand.

    Science.gov (United States)

    Kijsanayotin, Boonchai; Pannarunothai, Supasit; Speedie, Stuart

    2005-01-01

    Knowledge about socio-technical aspects of information technology (IT) is vital for the success of health IT projects. The Thailand health administration anticipates using health IT to support the recently implemented national universal health care system. However, the national knowledge associate with the socio-technical aspects of health IT has not been studied in Thailand. A survey instrument measuring Thai health center (HC) personnel's computer use, basic IT knowledge and HC computerized information system functionality needs was developed. The instrument reveals acceptable test-retest reliability and reasonable internal consistency of the measures. The future nation-wide demonstration study will benefit from this study.

  6. A computerized method of estimation of sensor motor reaction, complicated with additional cognitive component

    Directory of Open Access Journals (Sweden)

    Gennadij V. Ganin

    2011-05-01

    Full Text Available This article is related to new integrated approach to objective computerizing evaluation of cognitive-component which delays the latent period of the sensor-motor reaction on specific visual stimuli, which carried different semantic information. It is recommended to use this method for clinical diagnostic of pathologies associated with disorders of cognitive human activity and for assessment of mental fatigue.

  7. DYNAMICS OF VIEWS ON ETHICS OF PEDAGOGICAL DIAGNOSTICS IN INFORMATION AND COMMUNICATION LEARNING ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Oleksandr Kolgatin

    2016-11-01

    Full Text Available Didactical demands for pedagogical diagnostics and its realisation specific characters in information and communication learning environment of university are analysed. The questions of ethics and information security of pedagogical diagnostics are considered. Ethic aspects, connected with using of the automated pedagogical diagnostic systems, are underlined. Results of survey of students about their view points on issues of security of pedagogical diagnostics data are discussed.

  8. Assessment Stability and Informative of Diagnostic Matrix in Analysis States of Reinforced Concrete Slab

    Directory of Open Access Journals (Sweden)

    Sokolov Vladimir

    2016-01-01

    Full Text Available In this article was examined the issues of sustainability and informative of diagnostic matrix, which are used when it is necessary to determinate the technical condition of constructions. Determination based on the mathematical instrument of technical diagnostics. One of the most widespread methods of technical diagnostics – a statistical method of Bayes is used.

  9. The Role of Radiology in the Diagnostic Process: Information, Communication, and Teamwork.

    Science.gov (United States)

    Larson, David B; Langlotz, Curtis P

    2017-11-01

    The diagnostic radiology process represents a partnership between clinical and radiology teams. As such, breakdowns in interpersonal interactions and communication can result in patient harm. We explore the role of radiology in the diagnostic process, focusing on key concepts of information and communication, as well as key interpersonal interactions of teamwork, collaboration, and collegiality, all based on trust. We propose 10 principles to facilitate effective information flow in the diagnostic process.

  10. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  11. Computerizing marine biota: a rational approach

    Digital Repository Service at National Institute of Oceanography (India)

    Chavan, V.S.; Chandramohan, D.; Parulekar, A.H.

    Data on marine biota while being extensive are also patchy and scattered; thus making retrieval and dissemination of information time consuming. This emphasise the need for computerizing information on marine biota with the objective to collate...

  12. Using Meta-Analysis to Inform the Design of Subsequent Studies of Diagnostic Test Accuracy

    Science.gov (United States)

    Hinchliffe, Sally R.; Crowther, Michael J.; Phillips, Robert S.; Sutton, Alex J.

    2013-01-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial…

  13. Comparison of Diagnostic Information from Regular Telemetry Equipment and a Novel Patch Type Electrocardiogram Recorder

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Egstrup, Kenneth; Hoppe, Karsten

    2014-01-01

    The purpose of this pilot study is to compare the diagnostic information obtained using regular telemetry equipment and the novel ePatch heart monitor. The comparison was conducted by a cardiologist on 24-hour recordings from 11 admitted patients. For all 11 recordings, the same diagnostic inform...

  14. Computerized tomography

    International Nuclear Information System (INIS)

    Caille, J.M.; Salamon, G.

    1980-01-01

    As X-ray Ct becomes more commonplace, other techniques of investigation using roughly comparable hardware and software have appeared. Positron-Emission Tomography already provides indispensable physiological and physio-pathological information. Similarly, in the histo-chemical field, Nuclear Magnetic Resonance seems very promising. Some of these new techniques will no doubt shortly be considered as essential as CT in establishing accurate diagnoses non-invasively. (orig./VJ) [de

  15. Reducing Diagnostic Errors through Effective Communication: Harnessing the Power of Information Technology

    Science.gov (United States)

    Naik, Aanand Dinkar; Rao, Raghuram; Petersen, Laura Ann

    2008-01-01

    Diagnostic errors are poorly understood despite being a frequent cause of medical errors. Recent efforts have aimed to advance the "basic science" of diagnostic error prevention by tracing errors to their most basic origins. Although a refined theory of diagnostic error prevention will take years to formulate, we focus on communication breakdown, a major contributor to diagnostic errors and an increasingly recognized preventable factor in medical mishaps. We describe a comprehensive framework that integrates the potential sources of communication breakdowns within the diagnostic process and identifies vulnerable steps in the diagnostic process where various types of communication breakdowns can precipitate error. We then discuss potential information technology-based interventions that may have efficacy in preventing one or more forms of these breakdowns. These possible intervention strategies include using new technologies to enhance communication between health providers and health systems, improve patient involvement, and facilitate management of information in the medical record. PMID:18373151

  16. Efficiency of computerized tomography in comparison with other neuroradiological investigation methods

    International Nuclear Information System (INIS)

    Kretzschmar, H.

    1979-01-01

    Computerized tomography is considered to be a decisive and the most reliable investigation method for the diagnosis of cerebral tumors. The rate of detection of intracranial blastomas is over 90%. Supratentorial growths are more easy to prove than tumors at the posterior cranial fossa. In the group of patients examined, 97.3% of the cerebral tumors were confirmed by computerized tomography: 98.7% of these were located above the tentorium and 89.3% under the tentorium. But the diagnostic value of computerized tomography is not only due to the high growth detection rate but also to its informative power as regards the position of growths in relation to vital centres, the type of the blastomas and their space-occupying effect. Thus this investigation method permits to evaluate the complex ''space occupation'' at one glance. By the angiographic method cerebral growths are confirmed in 86% of the cases; 88.6% of these are located above the tentorium. (orig.) [de

  17. Computerized operator support system for the JMTR: ARGUS

    International Nuclear Information System (INIS)

    Oyamada, R.; Yamamoto, K.; Ishii, Y.; Sekine, N.; Nemoto, N.

    1988-01-01

    ARGUS is computerized operator support system developed for the JMTR Function keybords, alphanumic keybords, and colour display terminals serve as comminication interface between ARGUS and operating personnel. ARGUS serves the following purposes; 1) data logging, 2) early abnormality detection, 3) presenting relevant and concentrated information to the operators to support their accurate judgment in case of abnormality occurrence, 4) save of time-historical data for diagnostics, and 5) data base necessary for JMTR operation and maintenance. ARGUS has been implemented on a VAX-11/750 with mos memories of 7.25 MB. (author)

  18. Diagnostic Accuracy of Dual-Source Computerized Tomography Coronary Angiography in Symptomatic Patients Presenting to a Referral Cardiovascular Center During Daily Clinical Practice

    International Nuclear Information System (INIS)

    Mahdavi, Arash; Mohammadzadeh, Ali; Joodi, Golsa; Tabatabaei, Mohammad Reza; Sheikholeslami, Farhad; Motevalli, Marzieh

    2016-01-01

    There are numerous studies that address the diagnostic value of dual-source computed tomography (DSCT) as an alternative to conventional coronary angiography (CCA). However, the benefit of application of DSCT in a real world clinical setting should be evaluated. To determine the diagnostic accuracy of DSCT technique compared with CCA as the gold standard method in detection of coronary artery stenosis among symptomatic patients who are presented to a referral cardiovascular center during daily clinical practice. Evaluating the medical records of a tertiary care referral cardiovascular center, 47 patients who had undergone DSCT and CCA, and also met the inclusion and exclusion criteria of the study were selected. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratios (LRs) of the DSCT imaging technique were calculated. In total, 97.8% of the segments (628/642) could be visualized with diagnostic image quality via DSCT coronary angiography. The mean heart rate during DSCT was 69.2 ± 12.2 bpm (range: 39 - 83 bpm), and the mean Agatston score was 507.7 ± 590.5 (range: 0 - 2328). Per segment analysis of the findings revealed that the sensitivity, specificity, PPV, NPV, positive LR (PLR) and negative LR (NLR) of DSCT technique for evaluation of patients with coronary artery disease were 93.7%, 96.8%, 92.7%, 97.2%, 29.4, and 0.066, respectively. Also per vessel, analysis of the findings showed a sensitivity of 97.1%, a specificity of 94.0%, PPV of 95.3%, NPV of 96.3%, PLR of 16.1, and NLR of 0.030. Our results indicate that DSCT coronary angiography provides high diagnostic accuracy for the evaluation of CAD patients during daily routine practice of a referral cardiovascular setting

  19. Informativeness of Diagnostic Marker Values and the Impact of Data Grouping.

    Science.gov (United States)

    Ma, Hua; Bandos, Andriy I; Gur, David

    2018-01-01

    Assessing performance of diagnostic markers is a necessary step for their use in decision making regarding various conditions of interest in diagnostic medicine and other fields. Globally useful markers could, however, have ranges of values that are " diagnostically non-informative" . This paper demonstrates that the presence of marker values from diagnostically non-informative ranges could lead to a loss in statistical efficiency during nonparametric evaluation and shows that grouping non-informative values provides a natural resolution to this problem. These points are theoretically proven and an extensive simulation study is conducted to illustrate the possible benefits of using grouped marker values in a number of practically reasonable scenarios. The results contradict the common conjecture regarding the detrimental effect of grouped marker values during performance assessments. Specifically, contrary to the common assumption that grouped marker values lead to bias, grouping non-informative values does not introduce bias and could substantially reduce sampling variability. The proven concept that grouped marker values could be statistically beneficial without detrimental consequences implies that in practice, tied values do not always require resolution whereas the use of continuous diagnostic results without addressing diagnostically non-informative ranges could be statistically detrimental. Based on these findings, more efficient methods for evaluating diagnostic markers could be developed.

  20. Future-oriented computerized information system for power plant process control in a pilot project at Philippsburg nuclear power plant

    International Nuclear Information System (INIS)

    Woehrle, G.; Kraft, M.

    1988-01-01

    The motivation for the pilot project at Philippsburg nuclear power plant resulted from the Three Mile Island accident in 1979. The primary task embraces an efficient computer-aided reduction of information when a fault occurs based on a process engineering analysis of the information accrued. Accompanying this are a consolidation and evaluation of the information available in the control room. In this pilot project the new tasks of status monitoring, information reduction and operationalcontrol have been realized for the first time using a computer-aided process information system. In addition to the existing control computer, an information computer with approximately 1200 analogue and about 10000 binary signals has been installed. The installation of the system was completed in 1984 and in the meantime initial operational experience has become available. (orig.) [de

  1. A Management Information System Model for Program Management. Ph.D. Thesis - Oklahoma State Univ.; [Computerized Systems Analysis

    Science.gov (United States)

    Shipman, D. L.

    1972-01-01

    The development of a model to simulate the information system of a program management type of organization is reported. The model statistically determines the following parameters: type of messages, destinations, delivery durations, type processing, processing durations, communication channels, outgoing messages, and priorites. The total management information system of the program management organization is considered, including formal and informal information flows and both facilities and equipment. The model is written in General Purpose System Simulation 2 computer programming language for use on the Univac 1108, Executive 8 computer. The model is simulated on a daily basis and collects queue and resource utilization statistics for each decision point. The statistics are then used by management to evaluate proposed resource allocations, to evaluate proposed changes to the system, and to identify potential problem areas. The model employs both empirical and theoretical distributions which are adjusted to simulate the information flow being studied.

  2. USING THE INFORMATION OF ON-BOARD DIAGNOSTIC SYSTEMS IN DETERMINING THE TECHNICAL STATE OF THE LOCOMOTIVE

    Directory of Open Access Journals (Sweden)

    B. Ye. Bodnar

    2008-12-01

    Full Text Available The issues of increase of efficiency of information processing by оn-board systems of diagnostics of locomotives are considered. The examples of information processing by the on-board system of diagnostics of electric locomotives DE1 are presented. The suggestions on improvement of systematization and processing of information by on-board systems of diagnostics are given.

  3. Information matrix estimation procedures for cognitive diagnostic models.

    Science.gov (United States)

    Liu, Yanlou; Xin, Tao; Andersson, Björn; Tian, Wei

    2018-03-06

    Two new methods to estimate the asymptotic covariance matrix for marginal maximum likelihood estimation of cognitive diagnosis models (CDMs), the inverse of the observed information matrix and the sandwich-type estimator, are introduced. Unlike several previous covariance matrix estimators, the new methods take into account both the item and structural parameters. The relationships between the observed information matrix, the empirical cross-product information matrix, the sandwich-type covariance matrix and the two approaches proposed by de la Torre (2009, J. Educ. Behav. Stat., 34, 115) are discussed. Simulation results show that, for a correctly specified CDM and Q-matrix or with a slightly misspecified probability model, the observed information matrix and the sandwich-type covariance matrix exhibit good performance with respect to providing consistent standard errors of item parameter estimates. However, with substantial model misspecification only the sandwich-type covariance matrix exhibits robust performance. © 2018 The British Psychological Society.

  4. Methodology of nuclear reactor monitoring and diagnostics using information dimension

    International Nuclear Information System (INIS)

    Suzudo, Tomoaki; Hayashi, Koji; Shinohara, Yoshikuni

    1993-01-01

    Reactor noise analysis method based on information dimension is applied to the monitoring and diagnosing of power oscillation. The method focuses on the utilization of the slope of the correlation integral (SOCI) which determines the information dimension of attractors. For practical application, the information dimension is expected to be the same as the fractal dimension of attractors; it can be used to classify different asymptotic regimes of nonlinear dynamical systems. We examined a real power oscillation using SOCI and the results implied that the oscillation was just a noisy limit cycle, although it is not possible to assert that there is no chaotic character in the oscillation because large oscillatory time-series data sets are not available. In addition, the application of SOCI to the real-time monitoring of power oscillation is proposed and examined. (author)

  5. The integrated workstation: A common, consistent link between nuclear plant personnel and plant information and computerized resources

    International Nuclear Information System (INIS)

    Wood, R.T.; Knee, H.E.; Mullens, J.A.; Munro, J.K. Jr.; Swail, B.K.; Tapp, P.A.

    1993-01-01

    The increasing use of computer technology in the US nuclear power industry has greatly expanded the capability to obtain, analyze, and present data about the plant to station personnel. Data concerning a power plant's design, configuration, operational and maintenance histories, and current status, and the information that can be derived from them, provide the link between the plant and plant staff. It is through this information bridge that operations, maintenance and engineering personnel understand and manage plant performance. However, it is necessary to transform the vast quantity of data available from various computer systems and across communications networks into clear, concise, and coherent information. In addition, it is important to organize this information into a consolidated, structured form within an integrated environment so that various users throughout the plant have ready access at their local station to knowledge necessary for their tasks. Thus, integrated workstations are needed to provide the inquired information and proper software tools, in a manner that can be easily understood and used, to the proper users throughout the plant. An effort is underway at the Oak Ridge National Laboratory to address this need by developing Integrated Workstation functional requirements and implementing a limited-scale prototype demonstration. The integrated Workstation requirements will define a flexible, expandable computer environment that permits a tailored implementation of workstation capabilities and facilitates future upgrades to add enhanced applications. The functionality to be supported by the integrated workstation and inherent capabilities to be provided by the workstation environment win be described. In addition, general technology areas which are to be addressed in the Integrated Workstation functional requirements will be discussed

  6. Computerized tomography of the vertebral column following traumatic lesion

    International Nuclear Information System (INIS)

    Taenzer, B.; Gmelin, E.; Burmester, E.; Babaian, E.; Weiss, H.D.; Hohlbach, G.

    1984-01-01

    In 58 patients with lesions of the vertebral column in the thoracal and lumbar section established by conventional X-ray, the informative power of computerized tomography was tested. Axial projection with the superimposition-free presentation of bone and soft-tissue structures in the motional segment clears up the diagnostically decisive question of the extent of the lesion and form of fracture, and thus provides information on the stability or instability of the fracture relevant for the therapeutic action taken. All patients had compression fractures of vertebrae, with a fragment of the front edge broken away in 50 cases and one of the back edge broken away in 17 cases. In 30 cases the intervertebral disks were damaged. 43 fractures were stable, 25 were unstable. The instability of 13 fractures was only recognized by CT. In essence, the diagnostic action to be taken begins with a grand-survey X-ray in two planes as a screening, with computerized tomography following in the positive case. Conventional tomograms are not necessary. (BWU) [de

  7. Quantitative inspection by computerized tomography

    International Nuclear Information System (INIS)

    Lopes, R.T.; Assis, J.T. de; Jesus, E.F.O. de

    1989-01-01

    The computerized Tomography (CT) is a method of nondestructive testing, that furnish quantitative information, that permit the detection and accurate localization of defects, internal dimension measurement, and, measurement and chart of the density distribution. The CT technology is much versatile, not presenting restriction in relation to form, size or composition of the object. A tomographic system, projected and constructed in our laboratory is presented. The applications and limitation of this system, illustrated by tomographyc images, are shown. (V.R.B.)

  8. Computerized tomography in endocrinology

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Schmiedl, U.; Huebener, K.H.

    1987-01-05

    The role of CT in the evaluation of endocrinologic disorders is discussed and typical CT-findings in disease of the hypophysis, the thyroid, the parathyroid, the thymus and the pancreas are shown. Special interest is laid on adrenal disorders. This survey informs the clinician about the diagnostic value of CT in endocrinology.

  9. Computerized tomography in endocrinology

    International Nuclear Information System (INIS)

    Kurtz, B.; Schmiedl, U.; Huebener, K.H.

    1987-01-01

    The role of CT in the evaluation of endocrinologic disorders is discussed and typical CT-findings in disease of the hypophysis, the thyroid, the parathyroid, the thymus and the pancreas are shown. Special interest is laid on adrenal disorders. This survey informs the clinician about the diagnostic value of CT in endocrinology. (orig.) [de

  10. Computerized tomography in the diagnosis of hyperparathyroidism

    International Nuclear Information System (INIS)

    Sobota, J.; Girl, J.; Sotornik, I.; Kocandrle, V.

    1990-01-01

    Long-term experience in the application of computerized tomography to the diagnosis of hyperparathyroidism is summarized. Based on a large number of examinations (164) of parathyroid glands associated with the possibility of verification and comparison with the results of ultrasonography and other imaging methods, the potential of computerized tomography in the diagnosis of hyperparathyroidism and its advantages and limitations are summarized. It is concluded that owing to its high diagnostic precision, this technique can be regarded reliable in detecting enlarged parathyroid glands. (author). 11 figs., 1 tab., 19 refs

  11. INIS Pioneering Information Management: The early days of computerized acquisition, processing and storage of data at the IAEA

    International Nuclear Information System (INIS)

    Rubini, Riccardo

    2015-01-01

    In his third Law, British author, Sir Arthur C. Clarke, states that “any sufficiently advanced technology is indistinguishable from magic”. When a technology becomes estranged due to the inevitable process of obsolescence, it becomes alien to the untrained eye, unfamiliar and obscure – elements that possibly add up on the original mystique of early computers. In this article we will take a look at a number of early information technologies, some gone, some forgotten, some still alive-and-well, to unveil the magic that has greatly contributed to INIS, throughout its 45 year journey in the realms of nuclear culture for peaceful uses

  12. Computerized tomography in orthopaedics and traumatology

    International Nuclear Information System (INIS)

    Boettger, E.; Heckl, R.; Rehabilitations-Krankenhaus Langensteinbach, Karlsbad

    1981-01-01

    Computerized tomography in traumatology is the selected method for the indications mentioned, so that angiographic investigations are only necessary in exceptional cases. Computerized tomography is also better than other methods when diagnozing soft part tumours, however, angiography is still indicated preoperatively for individual cases. CT is only good as additional help to conventional diagnostics with bone tumours. The differential diagnosis cysts-tumour is possible using contrast medium injections. The frequently large soft part share of tumours is recognizable with osteolytic tumours so that a better irradiation and operation planning can be effected. Diseases in the spinal canal can only be assessed with reservation using modern equipment. Lumbar dislocations of the disk can mostly not be sufficiently determined. Perivertebral abscesses can be certainly detected using computerized tomography. This is particularly so for abscesses prior to calcification. (orig.) [de

  13. Validation of Patient-Reported Outcomes Measurement Information System (PROMIS) computerized adaptive tests in cervical spine surgery.

    Science.gov (United States)

    Boody, Barrett S; Bhatt, Surabhi; Mazmudar, Aditya S; Hsu, Wellington K; Rothrock, Nan E; Patel, Alpesh A

    2018-03-01

    OBJECTIVE The Patient-Reported Outcomes Measurement Information System (PROMIS), which is funded by the National Institutes of Health, is a set of adaptive, responsive assessment tools that measures patient-reported health status. PROMIS measures have not been validated for surgical patients with cervical spine disorders. The objective of this project is to evaluate the validity (e.g., convergent validity, known-groups validity, responsiveness to change) of PROMIS computer adaptive tests (CATs) for pain behavior, pain interference, and physical function in patients undergoing cervical spine surgery. METHODS The legacy outcome measures Neck Disability Index (NDI) and SF-12 were used as comparisons with PROMIS measures. PROMIS CATs, NDI-10, and SF-12 measures were administered prospectively to 59 consecutive tertiary hospital patients who were treated surgically for degenerative cervical spine disorders. A subscore of NDI-5 was calculated from NDI-10 by eliminating the lifting, headaches, pain intensity, reading, and driving sections and multiplying the final score by 4. Assessments were administered preoperatively (baseline) and postoperatively at 6 weeks and 3 months. Patients presenting for revision surgery, tumor, infection, or trauma were excluded. Participants completed the measures in Assessment Center, an online data collection tool accessed by using a secure login and password on a tablet computer. Subgroup analysis was also performed based on a primary diagnosis of either cervical radiculopathy or cervical myelopathy. RESULTS Convergent validity for PROMIS CATs was supported with multiple statistically significant correlations with the existing legacy measures, NDI and SF-12, at baseline. Furthermore, PROMIS CATs demonstrated known-group validity and identified clinically significant improvements in all measures after surgical intervention. In the cervical radiculopathy and myelopathic cohorts, the PROMIS measures demonstrated similar responsiveness to the

  14. Beyond the 2×2 -contingency table: a primer on entropies and mutual information in various scenarios involving m diagnostic categories and n categories of diagnostic tests.

    Science.gov (United States)

    Reibnegger, Gilbert

    2013-10-21

    Usual evaluation tools for diagnostic tests such as, sensitivity/specificity and ROC analyses, are designed for the discrimination between two diagnostic categories, using dichotomous test results. Information theoretical quantities such as mutual information allow in depth-analysis of more complex discrimination problems, including continuous test results, but are rarely used in clinical chemistry. This paper provides a primer on useful information theoretical concepts with a strong focus on typical diagnostic scenarios. Information theoretical concepts are shortly explained. Mathematica CDF documents are provided which compute entropies and mutual information as function of pretest probabilities and the distribution of test results among the categories, and allow interactive exploration of the behavior of these quantities in comparison with more conventional diagnostic measures. Using data from a previously published study, the application of information theory to practical diagnostic problems involving up to 4×4 -contingency tables is demonstrated. Information theoretical concepts are particularly useful for diagnostic problems requiring more than the usual binary classification. Quantitative test results can be properly analyzed, and in contrast to popular concepts such as ROC analysis, the effects of variations of pre-test probabilities of the diagnostic categories can be explicitly taken into account. © 2013 Elsevier B.V. All rights reserved.

  15. Evaluation of brain scintigraphy and computerized tomography

    International Nuclear Information System (INIS)

    Cavailloles, F.; Dairou, R.; Desbleds, M.T.; Benoit, C.; Larmande, P.; Bok, B.; Alperovitch, A.

    1983-01-01

    In order to assess the clinical usefulness of brain computerized tomography and radionuclide scan, a prospective study was performed on a series of 554 patients. The detection rate was assessed as well as the identification rate of lesions. In addition, the usefulness of both tests was appreciated subjectively by two neurologists reviewing the patients' files. Both give reasonably similar results: computerized tomography is superior to radionuclide scan in the diagnosis of tumors and intracerebral hematomas, the radionuclide scan being slightly superior in the diagnosis of purely ischemic CVA and subdural hematomas. The superiority which was subjectively conceded to computerized tomography was greater than that objectively demonstrated. However, clinical usefulness of computerized tomography was judged important in only 50% of the cases. Moreover, to request both computerized tomography and radionuclide scan appeared as having no interest in 83% of the cases. In that series, the diagnostic hypotheses were in agreement with the final diagnosis in 88% of the cases. Bias encountered in this type of studies are discussed [fr

  16. About increasing informativity of diagnostic system of asynchronous electric motor by extracting additional information from values of consumed current parameter

    Science.gov (United States)

    Zhukovskiy, Y.; Korolev, N.; Koteleva, N.

    2018-05-01

    This article is devoted to expanding the possibilities of assessing the technical state of the current consumption of asynchronous electric drives, as well as increasing the information capacity of diagnostic methods, in conditions of limited access to equipment and incompleteness of information. The method of spectral analysis of the electric drive current can be supplemented by an analysis of the components of the current of the Park's vector. The research of the hodograph evolution in the moment of appearance and development of defects was carried out using the example of current asymmetry in the phases of an induction motor. The result of the study is the new diagnostic parameters of the asynchronous electric drive. During the research, it was proved that the proposed diagnostic parameters allow determining the type and level of the defect. At the same time, there is no need to stop the equipment and taky it out of service for repair. Modern digital control and monitoring systems can use the proposed parameters based on the stator current of an electrical machine to improve the accuracy and reliability of obtaining diagnostic patterns and predicting their changes in order to improve the equipment maintenance systems. This approach can also be used in systems and objects where there are significant parasitic vibrations and unsteady loads. The extraction of useful information can be carried out in electric drive systems in the structure of which there is a power electric converter.

  17. Computerized accounting methods. Final report

    International Nuclear Information System (INIS)

    1994-01-01

    This report summarizes the results of the research performed under the Task Order on computerized accounting methods in a period from 03 August to 31 December 1994. Computerized nuclear material accounting methods are analyzed and evaluated. Selected methods are implemented in a hardware-software complex developed as a prototype of the local network-based CONMIT system. This complex has been put into trial operation for test and evaluation of the selected methods at two selected ''Kurchatov Institute'' Russian Research Center (''KI'' RRC) nuclear facilities. Trial operation is carried out since the beginning of Initial Physical Inventory Taking in these facilities that was performed in November 1994. Operation of CONMIT prototype system was demonstrated in the middle of December 1994. Results of evaluation of CONMIT prototype system features and functioning under real operating conditions are considered. Conclusions are formulated on the ways of further development of computerized nuclear material accounting methods. The most important conclusion is a need to strengthen computer and information security features supported by the operating environment. Security provisions as well as other LANL Client/Server System approaches being developed by Los Alamos National Laboratory are recommended for selection of software and hardware components to be integrated into production version of CONMIT system for KI RRC

  18. Development of an Information Fusion System for Engine Diagnostics and Health Management

    Science.gov (United States)

    Volponi, Allan J.; Brotherton, Tom; Luppold, Robert; Simon, Donald L.

    2004-01-01

    Aircraft gas-turbine engine data are available from a variety of sources including on-board sensor measurements, maintenance histories, and component models. An ultimate goal of Propulsion Health Management (PHM) is to maximize the amount of meaningful information that can be extracted from disparate data sources to obtain comprehensive diagnostic and prognostic knowledge regarding the health of the engine. Data Fusion is the integration of data or information from multiple sources, to achieve improved accuracy and more specific inferences than can be obtained from the use of a single sensor alone. The basic tenet underlying the data/information fusion concept is to leverage all available information to enhance diagnostic visibility, increase diagnostic reliability and reduce the number of diagnostic false alarms. This paper describes a basic PHM Data Fusion architecture being developed in alignment with the NASA C17 Propulsion Health Management (PHM) Flight Test program. The challenge of how to maximize the meaningful information extracted from disparate data sources to obtain enhanced diagnostic and prognostic information regarding the health and condition of the engine is the primary goal of this endeavor. To address this challenge, NASA Glenn Research Center (GRC), NASA Dryden Flight Research Center (DFRC) and Pratt & Whitney (P&W) have formed a team with several small innovative technology companies to plan and conduct a research project in the area of data fusion as applied to PHM. Methodologies being developed and evaluated have been drawn from a wide range of areas including artificial intelligence, pattern recognition, statistical estimation, and fuzzy logic. This paper will provide a broad overview of this work, discuss some of the methodologies employed and give some illustrative examples.

  19. Use of computerized tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tjoerstad, K.

    1992-01-01

    This is a neurologist's opinion on how computerized tomography and magnetic resonance imaging have improved the doctor's diagnostic possibilities, changed patient/doctor relationship and increased the patients' expectations from diagnostic tests. How should the often conflicting interests of patients, society and doctors be handled? 15 refs., 1 fig., 1 tab

  20. How will computerization revolutionize managed care?

    Science.gov (United States)

    Trabin, T

    1994-01-01

    Computerization of behavioral health care information systems is revolutionizing how payors, managed care companies, and providers exchange information. In this article, an imaginary scenario is depicted of how patient data will be accessed and communicated to facilitate care management of behavioral health care services in the near future.

  1. Textbook on X-ray diagnostics. Substantiated by Marianne Zimmer-Brossy. 6. new rev. ed.

    International Nuclear Information System (INIS)

    Becht, Stefanie; Bittner, Roland C.; Ohmstede, Anke; Pfeiffer, Andreas; Rossdeutscher, Reinhard

    2008-01-01

    The standard textbook on x-ray diagnostics has been revised by the MTRA team and radiologists: The book covers the following topics: General information: the profession of a radiologist, the x-ray department, radiation protection, quality assurance, basic physics, x-ray imaging, analog and digital image processing, archives, image interpretation. Skeleton diagnostics; Inner organs (thorax organs, neck, abdomen, gastrointestinal tract, colon, gall bladder and biliary tract): Special x-ray diagnostic methods: x-ray diagnostic of the female and male chest, x-ray diagnostics of bone joints (arthrography, and contrast media), x-ray diagnostics of the urinary-genital system, x-ray diagnostics of cavities and syrinx, x-ray diagnostics of arteries (arteriography, angiography), percutaneous transluminal angioplasty, x-ray diagnostics of veins (phlebography), x-ray diagnostics of lymphatic vessels and lymph nodes, x-ray diagnostics of spinal cord (myelography); Specific imaging methods: computerized tomography [de

  2. Using qualitative research to inform development of a diagnostic algorithm for UTI in children.

    Science.gov (United States)

    de Salis, Isabel; Whiting, Penny; Sterne, Jonathan A C; Hay, Alastair D

    2013-06-01

    Diagnostic and prognostic algorithms can help reduce clinical uncertainty. The selection of candidate symptoms and signs to be measured in case report forms (CRFs) for potential inclusion in diagnostic algorithms needs to be comprehensive, clearly formulated and relevant for end users. To investigate whether qualitative methods could assist in designing CRFs in research developing diagnostic algorithms. Specifically, the study sought to establish whether qualitative methods could have assisted in designing the CRF for the Health Technology Association funded Diagnosis of Urinary Tract infection in Young children (DUTY) study, which will develop a diagnostic algorithm to improve recognition of urinary tract infection (UTI) in children aged children in primary care and a Children's Emergency Department. We elicited features that clinicians believed useful in diagnosing UTI and compared these for presence or absence and terminology with the DUTY CRF. Despite much agreement between clinicians' accounts and the DUTY CRFs, we identified a small number of potentially important symptoms and signs not included in the CRF and some included items that could have been reworded to improve understanding and final data analysis. This study uniquely demonstrates the role of qualitative methods in the design and content of CRFs used for developing diagnostic (and prognostic) algorithms. Research groups developing such algorithms should consider using qualitative methods to inform the selection and wording of candidate symptoms and signs.

  3. Computerized tomography of orbital lesions

    International Nuclear Information System (INIS)

    Kuroiwa, Mayumi

    1981-01-01

    Two different types of computerized tomography scanners (CT scanner), i.e. a whole-body CT scanner (GE-CT/T8800) and a cerebral CT scanner (EMI-1010), were compared in the assessment and diagnosis of various orbital lesions. The whole-body CT scanner was found to be advantageous over the cerebral CT scanner for the following reasons: (1) CT images were more informative due to thinner slices associated with smaller-sized and larger-numbered matrices; (2) less artifacts derived from motion of the head or eyeball were produced because of the shorter scanning time; (3) with a devised gantry, coronal dissections were available whenever demanded. (author)

  4. Quality of information accompanying on-line marketing of home diagnostic tests.

    Science.gov (United States)

    Datta, Adrija K; Selman, Tara J; Kwok, Tony; Tang, Teresa; Khan, Khalid S

    2008-01-01

    To assess the quality of information provided to consumers by websites marketing medical home diagnostic tests. A cross-sectional analysis of a database developed from searching targeted websites. Data sources were websites written in English which marketed medical home diagnostic tests. A meta-search engine was used to identify the first 20 citations for each type of home diagnostic medical test. Relevant websites limited to those written in English were reviewed independently and in triplicate, with disputes resolved by two further reviewers. Information on the quality of these sites was extracted using a pre-piloted performer. 168 websites were suitable for inclusion in the review. The quality of these sites showed marked variation. Only 24 of 168 (14.2%) complied with at least three-quarters of the quality items and just over half (95 of 168, 56.5%) reported official approval or certification of the test. Information on accuracy of the test marketed was reported by 87 of 168 (51.7%) websites, with 15 of 168 (8.9%) providing a scientific reference. Instructions for use of the product were found in 97 of 168 (57.9%). However, the course of action to be taken after obtaining the test result was stated in only 63 of 168 (37.5%) for a positive result and 43 of 168 (25.5%) for a negative result. The quality of information posted on commercial websites marketing home tests online is unsatisfactory and potentially misleading for consumers.

  5. Method for Evaluating Information to Solve Problems of Control, Monitoring and Diagnostics

    Science.gov (United States)

    Vasil'ev, V. A.; Dobrynina, N. V.

    2017-06-01

    The article describes a method for evaluating information to solve problems of control, monitoring and diagnostics. It is necessary for reducing the dimensionality of informational indicators of situations, bringing them to relative units, for calculating generalized information indicators on their basis, ranking them by characteristic levels, for calculating the efficiency criterion of a system functioning in real time. The design of information evaluation system has been developed on its basis that allows analyzing, processing and assessing information about the object. Such object can be a complex technical, economic and social system. The method and the based system thereof can find a wide application in the field of analysis, processing and evaluation of information on the functioning of the systems, regardless of their purpose, goals, tasks and complexity. For example, they can be used to assess the innovation capacities of industrial enterprises and management decisions.

  6. Data on multicultural education and diagnostic information profiling: Culture, learning styles and creativity.

    Science.gov (United States)

    Maseleno, Andino; Hardaker, Glenn; Sabani, Noraisikin; Suhaili, Nabilah

    2016-12-01

    This article contains data related to multicultural education and diagnostic information profiling preliminary findings. It includes the responses of 253 students. The data consists of six sections, i) culture: race, ethnicity, language and identity; ii) learning preferences: physiological and perceptual; iii) cognitive learning styles: physical, emotional and mental; iv) creativity skills and problem solving skills; v) motivation; and vi) students' background knowledge. The data may be used as part of data analytics for specific personalized e-learning platform.

  7. Data on multicultural education and diagnostic information profiling: Culture, learning styles and creativity

    Directory of Open Access Journals (Sweden)

    Andino Maseleno

    2016-12-01

    Full Text Available This article contains data related to multicultural education and diagnostic information profiling preliminary findings. It includes the responses of 253 students. The data consists of six sections, i culture: race, ethnicity, language and identity; ii learning preferences: physiological and perceptual; iii cognitive learning styles: physical, emotional and mental; iv creativity skills and problem solving skills; v motivation; and vi students’ background knowledge. The data may be used as part of data analytics for specific personalized e-learning platform.

  8. Evaluation of Diagnostic Tests Using Information Theory for Multi-Class Diagnostic Problems and its Application for the Detection of Occlusal Caries Lesions

    Directory of Open Access Journals (Sweden)

    Umut Arslan

    2014-09-01

    Full Text Available Background: Several methods are available to evaluate the performance of the tests when the purpose of the diagnostic test is to discriminate between two possible disease states. However multi-class diagnostic problems frequently appear in many areas of medical science. Hence, there is a need for methods which will enable us to characterize the accuracy of diagnostic tests when there are more than two possible disease states. Aims: To show that two information theory measures, information content (IC and proportional reduction in diagnostic uncertainty (PRDU, can be used for the evaluation of the performance of diagnostic tests for multi-class diagnostic problems that may appear in different areas of medical science. Study Design: Diagnostic accuracy study. Methods: Sixty freshly extracted permanent human molar and premolar teeth suspected to have occlusal caries lesions were selected for the study and were assessed by two experienced examiners. Each examiner performed two evaluations. Histological examination was used as the gold standard. The scores of the histological examination were defined as sound (n=11, enamel caries (n=22 and dentin caries (n=27. Diagnostic performance of i visual inspection, ii radiography, iii laser fluorescence (LF and iv micro-computed tomography (M-CT caries detection methods was evaluated by calculating IC and PRDU. Results: Micro-computed tomography examination was the best method among the diagnostic techniques for the diagnosis of occlusal caries in terms of both IC and PRDU. M-CT examination supplied the maximum diagnostic information about the diagnosis of occlusal caries in the first (IC: 1.056; p<0.05, (PRDU: 70.5% and second evaluation (IC: 1.105; p<0.05, (PRDU: 73.8% for the first examiner. M-CT examination was the best method among the diagnostic techniques for the second examiner in both the first (IC:1.105; p<0.05, (PRDU:73.8% and second evaluation (IC:1.061; p<0.05, (PRDU:70.8%. IC and PRDU were

  9. Computerization of the safeguards analysis decision process

    International Nuclear Information System (INIS)

    Ehinger, M.H.

    1990-01-01

    This paper reports that safeguards regulations are evolving to meet new demands for timeliness and sensitivity in detecting the loss or unauthorized use of sensitive nuclear materials. The opportunities to meet new rules, particularly in bulk processing plants, involve developing techniques which use modern, computerized process control and information systems. Using these computerized systems in the safeguards analysis involves all the challenges of the man-machine interface experienced in the typical process control application and adds new dimensions to accuracy requirements, data analysis, and alarm resolution in the regulatory environment

  10. Motion Estimation and Compensation Strategies in Dynamic Computerized Tomography

    Science.gov (United States)

    Hahn, Bernadette N.

    2017-12-01

    A main challenge in computerized tomography consists in imaging moving objects. Temporal changes during the measuring process lead to inconsistent data sets, and applying standard reconstruction techniques causes motion artefacts which can severely impose a reliable diagnostics. Therefore, novel reconstruction techniques are required which compensate for the dynamic behavior. This article builds on recent results from a microlocal analysis of the dynamic setting, which enable us to formulate efficient analytic motion compensation algorithms for contour extraction. Since these methods require information about the dynamic behavior, we further introduce a motion estimation approach which determines parameters of affine and certain non-affine deformations directly from measured motion-corrupted Radon-data. Our methods are illustrated with numerical examples for both types of motion.

  11. Computerized three-dimensional normal atlas

    International Nuclear Information System (INIS)

    Mano, Isamu; Suto, Yasuzo; Suzuki, Masataka; Iio, Masahiro.

    1990-01-01

    This paper presents our ongoing project in which normal human anatomy and its quantitative data are systematically arranged in a computer. The final product, the Computerized Three-Dimensional Normal Atlas, will be able to supply tomographic images in any direction, 3-D images, and coded information on organs, e.g., anatomical names, CT numbers, and T 1 and T 2 values. (author)

  12. Quality of information accompanying on-line marketing of home diagnostic tests

    Science.gov (United States)

    Datta, Adrija K; Selman, Tara J; Kwok, Tony; Tang, Teresa; Khan, Khalid S

    2008-01-01

    Objective To assess the quality of information provided to consumers by websites marketing medical home diagnostic tests. Design A cross-sectional analysis of a database developed from searching targeted websites. Setting Data sources were websites written in English which marketed medical home diagnostic tests. Main outcome measures A meta-search engine was used to identify the first 20 citations for each type of home diagnostic medical test. Relevant websites limited to those written in English were reviewed independently and in triplicate, with disputes resolved by two further reviewers. Information on the quality of these sites was extracted using a pre-piloted performer. Results 168 websites were suitable for inclusion in the review. The quality of these sites showed marked variation. Only 24 of 168 (14.2%) complied with at least three-quarters of the quality items and just over half (95 of 168, 56.5%) reported official approval or certification of the test. Information on accuracy of the test marketed was reported by 87 of 168 (51.7%) websites, with 15 of 168 (8.9%) providing a scientific reference. Instructions for use of the product were found in 97 of 168 (57.9%). However, the course of action to be taken after obtaining the test result was stated in only 63 of 168 (37.5%) for a positive result and 43 of 168 (25.5%) for a negative result. Conclusions The quality of information posted on commercial websites marketing home tests online is unsatisfactory and potentially misleading for consumers. PMID:18263912

  13. Cranial computerized tomography in children suffering from acute leukemia

    International Nuclear Information System (INIS)

    Metz, O.

    1981-01-01

    Cranial computerized (axial) tomography permits a more complete neurologic supervision of children with acute leukemia and a better knowledge of the frequency and varieties of cerebral complications in leukemia. Endocranial complications in acute leukemia are essentially infiltrative, hemorrhagic, infectious or iatrogenic. Cranial computerized tomography can demonstrate cerebral changes in meningeal leukemia, hemorrhages, calcifications, brain atrophy or leukencephalopathy. The preliminary results of cranial computerized tomography in childhood leukemia suggest that the iatrogenic main lesion of the brain due to combined radiation-chemotherapy is atrophy whereas that of the intrathecal cytostatic therapy is demyelination. Accurate diagnostics and control of possible cerebral complications in therapy of leukemia is essentially for appropriate therapeutic management. For that cranial computerized tomography is the best method to a effective supervision of the brain. (author)

  14. DOE transporation programs - computerized techniques

    Energy Technology Data Exchange (ETDEWEB)

    Joy, D.S.; Johnson, P.E.; Fore, C.S.; Peterson, B.E.

    1983-01-01

    One of the major thrusts of the transportation programs at the Oak Ridge National Laboratory has been the development of a number of computerized transportation programs and data bases. The U.S. Department of Energy (DOE) is supporting these efforts through the Transportation Technology Center at Sandia National Laboratories and the Tranportation Operations and Traffic Management (TOTM) organization at DOE Headquarters. Initially this project was centered upon research activities. However, since these tools provide traffic managers and key personnel involved in preshipment planning with a unique resource for ensuring that the movement of radioactive materials can be properly accomplished, additional interest and support is coming from the operational side of DOE. The major accomplishments include the development of two routing models (one for rail shipments and the other for highway shipments), an emergency response assistance program, and two data bases containing pertinent legislative and regulatory information. This paper discusses the mose recent advances in, and additions to, these computerized techniques and provides examples of how they are used.

  15. Computerized industrial tomography

    International Nuclear Information System (INIS)

    Ashraf, M.M.

    1999-01-01

    Computerized Tomographic (CT) has been used for a number of applications in the field of medicine and industry. For the last couple of years, the technique has been applied for the material characterization and detection of defects and flaws inside the industrial components of nuclear, aerospace and missile industries. A CT scanner of first generation was developed at the institute. The scanner has been used to demonstrate couple of applications of CT in the field of non destructive testing of materials. The data acquired by placing the test objects at various angles and scanning the object through a source detector assembly has been processed on a Pentium computer for image reconstruction using a filtered back projection method. The technique has been developed which can be modified and improved to study various other applications in materials science and a modern computerized tomographic facility can be established. (author)

  16. Computerized plant maintenance management

    International Nuclear Information System (INIS)

    Kozusko, A.M.

    1986-01-01

    The evolution of the computer has and continues to have a great impact on industry. We are in an adjustment cycle with the current computer evolution, and will need to adapt to make the changes for the coming decade. Hardware and software are continually being enhanced. Computers are becoming more powerful and will eventually provide an effective man-machine interface. This paper shares experiences encountered during implementations of computerized maintenance systems

  17. Computerized medical convocations

    International Nuclear Information System (INIS)

    Roche, Annie; Gilbert, Jean-Francois; Chiadot, Pierre; Vanzetto, Rene; Darnault, Jean

    1969-06-01

    Thanks to a close collaboration between the Medical and Social department and the Numerical Calculation Laboratory, a computerized convocation system has been implemented to reduce the administrative workload and to introduce more rigor in medical management, patient historical background and statistics. This work comprises: - a preliminary study of the data generating medical convocations and the related practical requirements; - the programming work according to these data; - the realisation of the mechano-graphical file covering the overall personnel [fr

  18. Mining for diagnostic information in body surface potential maps: A comparison of feature selection techniques

    Directory of Open Access Journals (Sweden)

    McCullagh Paul J

    2005-09-01

    Full Text Available Abstract Background In body surface potential mapping, increased spatial sampling is used to allow more accurate detection of a cardiac abnormality. Although diagnostically superior to more conventional electrocardiographic techniques, the perceived complexity of the Body Surface Potential Map (BSPM acquisition process has prohibited its acceptance in clinical practice. For this reason there is an interest in striking a compromise between the minimum number of electrocardiographic recording sites required to sample the maximum electrocardiographic information. Methods In the current study, several techniques widely used in the domains of data mining and knowledge discovery have been employed to mine for diagnostic information in 192 lead BSPMs. In particular, the Single Variable Classifier (SVC based filter and Sequential Forward Selection (SFS based wrapper approaches to feature selection have been implemented and evaluated. Using a set of recordings from 116 subjects, the diagnostic ability of subsets of 3, 6, 9, 12, 24 and 32 electrocardiographic recording sites have been evaluated based on their ability to correctly asses the presence or absence of Myocardial Infarction (MI. Results It was observed that the wrapper approach, using sequential forward selection and a 5 nearest neighbour classifier, was capable of choosing a set of 24 recording sites that could correctly classify 82.8% of BSPMs. Although the filter method performed slightly less favourably, the performance was comparable with a classification accuracy of 79.3%. In addition, experiments were conducted to show how (a features chosen using the wrapper approach were specific to the classifier used in the selection model, and (b lead subsets chosen were not necessarily unique. Conclusion It was concluded that both the filter and wrapper approaches adopted were suitable for guiding the choice of recording sites useful for determining the presence of MI. It should be noted however

  19. Triggering radiation alarm at security checks. Patients should be informed even after diagnostic nuclear medicine procedures.

    Science.gov (United States)

    Palumbo, Barbara; Neumann, Irmgard; Havlik, Ernst; Palumbo, Renato; Sinzinger, Helmut

    2009-01-01

    During the last few years an increasing number of nuclear medicine patients in various countries evoked a radiation alarm after therapeutic or diagnostic procedures, and even after passive exposure. A prospective calculation of activity retention in the patient's body is difficult due to extremely high variation of uptake and kinetics. Furthermore, different sensitivities and distances of the detectors make a prospective calculation even more difficult. In this article a number of cases are being reported, related problems are discussed and the surprisingly very limited literature reviewed. In order to minimize problems after eventually triggering alarms, we strongly recommend that each patient receives a certificate providing personal data, tracer, dose, half-life of the radionuclide, type and date of procedure applied as well as the nuclear medicine unit to contact for further information. Furthermore, a closer cooperation and exchange of information between the authorities and local nuclear medicine societies, would be welcome.

  20. Emission computerized-tomography and determination of local brain function

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Alavi, A.; Reivich, M.; Edwards, R.Q.; Fenton, C.A.; Zimmerman, R.A.

    1975-01-01

    Methods for the three dimensional reconstruction of /sup 99m/Tc brain scans are described. The diagnostic advantages of computerized tomography in the localization of brain tumors and in measurements of local cerebral blood flow are discussed. (U.S.)

  1. Computerized operator decision aids

    International Nuclear Information System (INIS)

    Long, A.B.

    1984-01-01

    This article explores the potential benefits associated with the use of computers in nuclear plants by the operating crew as an aid in making decisions. Pertinent findings are presented from recently completed projects to establish the context in which operating decisions have to be made. Key factors influencing the decision-making process itself are also identified. Safety parameter display systems, which are being implemented in various forms by the nuclear industry, are described within the context of decision making. In addition, relevant worldwide research and development activities are examined as potential enhancements to computerized operator decision aids to further improve plant safety and availability

  2. Computerized procedures system

    Science.gov (United States)

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  3. Computerized spleen volumetry

    International Nuclear Information System (INIS)

    Jahnke, T.; Mohring, R.; Schertel, L.

    1981-01-01

    We examined in experimental studies and clinical investigations on 34 patients in how far volumetry of the spleen can be carried out with a commonly available program, a whole-body computerized tomograph (SOMATOM) and an analytic equipment (EVALUSKOP). In this connection the authors tried to find also other ways of spleen volumetry by means of this unit combination. Our final result was that the given program for the usage of labelled areas presents itself as the best-suited technique for spleen volumetry which is also applicable in practice. (orig./MG) [de

  4. Computerized data base of the fundamental constants of nature

    International Nuclear Information System (INIS)

    Henry, E.A.; Hampel, V.E.

    1975-01-01

    Fifty-seven fundamental constants of nature were computerized from the up-to-date evaluations of E. R. Cohen and B. N. Taylor. The constants are annotated with regard to symbol, value, uncertainty, and scaling factor. This computerization is part of the scientific data base project of the Information Research Group at Lawrence Livermore Laboratory. The MASTER CONTROL data base management system is used. The computerized fundamental constants can be requested from the ERDA Computer Program Exchange and Information Center of the Argonne National Laboratory or from the National Technical Information Service of the U. S. Department of Commerce. This is the first of a series of releases on preparation of computerized scientific and technological data banks. The next release is a data bank of conversion factors for different units of measurements. 3 figures

  5. The value of diagnostic information to patients with suspected multiple sclerosis. Rochester-Toronto MRI Study Group.

    Science.gov (United States)

    Mushlin, A I; Mooney, C; Grow, V; Phelps, C E

    1994-01-01

    To determine the value of diagnostic information to patients with suspected multiple sclerosis (MS). Because treatment choices would be only minimally affected by earlier diagnosis for most patients with this clinical problem, this study assessed the "nondecisional" value of diagnosis. Prospective survey of patients before and after diagnostic workup, including imaging with magnetic resonance scanning. We assessed the effect of diagnostic information on patients' sense of well-being, as well as direct measures of the utility of information (using time trade-off and willingness-to-pay techniques). Patients referred from primary care practices for diagnostic workup for suspected MS to neurology clinics and practices. Sixty-eight individuals, mean age 37.5 years, 53 female and 15 male. Thirty-one patients were classified as having "probable MS," and 37 were classified as having "possible MS" by the examining neurologist before workup. Present and future health perception, uncertainty about diagnosis-prognosis, and level of anxiety. Willingness to pay for diagnostic information, quality of life as measured by the time trade-off technique, and psychological state of the patient before and after diagnosis. Diagnostic uncertainty fell significantly as a result of the diagnostic workup. Most patients (59/62) said that they were better off having received diagnostic information. Although anxiety seemed to be reduced by testing, overall anxiety levels did not decrease as much as anticipated. Patients also became less optimistic about their future health after testing. On average, patients were willing to forgo 4.5 quality-adjusted life days to receive an earlier diagnosis and their quality of life after diagnosis improved slightly. Subgroups of patients differed in their response to diagnostic information. Those in whom no definitive diagnosis emerged tend to be more anxious rather than being reassured by the "negative" workup. Individuals with "positive" workups became less

  6. Research on accounting transition from computerization to informationization

    Directory of Open Access Journals (Sweden)

    Shu Chen

    2017-11-01

    Full Text Available The application for computer technology, digitalization technology and network technology in the accounting field has promoted the development of accounting informationization. Accounting informationization is a product integrated with traditional accounting theory and modern information technology, which is an inevitable trend of continuous development of modern accounting. This paper discusses the basic concepts and characteristics of accounting computerization and informationization based on the normative research method and literature data method, analyzes the feasibility of accounting transition from computerization to informationization, and finally puts forward the specific approaches and ultimate goals of accounting transition from computerization to informationization.

  7. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  8. Methodology for vocational psychodiagnostics of senior schoolchildren using information technologies

    Science.gov (United States)

    Bogdanovskaya, I. M.; Kosheleva, A. N.; Kiselev, P. B.; Davydova, Yu. A.

    2017-01-01

    The article identifies the role and main problems of vocational psychodiagnostics in modern socio-cultural conditions. It analyzes the potentials of information technologies in vocational psychodiagnostics of senior schoolchildren. The article describes the theoretical and methodological grounds, content and diagnostic potentials of the computerized method in vocational psychodiagnostics. The computerized method includes three blocks of sub-tests to identify intellectual potential, personal qualities, professional interests and values, career orientations, as well as subtests to analyze the specific life experience of senior schoolchildren. The results of diagnostics allow developing an integrated psychodiagnostic conclusion with recommendations. The article contains options of software architecture for the given method.

  9. Location of core diagnostic information across various sequences in brain MRI and implications for efficiency of MRI scanner utilization.

    Science.gov (United States)

    Sharma, Aseem; Chatterjee, Arindam; Goyal, Manu; Parsons, Matthew S; Bartel, Seth

    2015-04-01

    Targeting redundancy within MRI can improve its cost-effective utilization. We sought to quantify potential redundancy in our brain MRI protocols. In this retrospective review, we aggregated 207 consecutive adults who underwent brain MRI and reviewed their medical records to document clinical indication, core diagnostic information provided by MRI, and its clinical impact. Contributory imaging abnormalities constituted positive core diagnostic information whereas absence of imaging abnormalities constituted negative core diagnostic information. The senior author selected core sequences deemed sufficient for extraction of core diagnostic information. For validating core sequences selection, four readers assessed the relative ease of extracting core diagnostic information from the core sequences. Potential redundancy was calculated by comparing the average number of core sequences to the average number of sequences obtained. Scanning had been performed using 9.4±2.8 sequences over 37.3±12.3 minutes. Core diagnostic information was deemed extractable from 2.1±1.1 core sequences, with an assumed scanning time of 8.6±4.8 minutes, reflecting a potential redundancy of 74.5%±19.1%. Potential redundancy was least in scans obtained for treatment planning (14.9%±25.7%) and highest in scans obtained for follow-up of benign diseases (81.4%±12.6%). In 97.4% of cases, all four readers considered core diagnostic information to be either easily extractable from core sequences or the ease to be equivalent to that from the entire study. With only one MRI lacking clinical impact (0.48%), overutilization did not seem to contribute to potential redundancy. High potential redundancy that can be targeted for more efficient scanner utilization exists in brain MRI protocols.

  10. Rapid and highly informative diagnostic assay for H5N1 influenza viruses.

    Directory of Open Access Journals (Sweden)

    Nader Pourmand

    Full Text Available A highly discriminative and information-rich diagnostic assay for H5N1 avian influenza would meet immediate patient care needs and provide valuable information for public health interventions, e.g., tracking of new and more dangerous variants by geographic area as well as avian-to-human or human-to-human transmission. In the present study, we have designed a rapid assay based on multilocus nucleic acid sequencing that focuses on the biologically significant regions of the H5N1 hemagglutinin gene. This allows the prediction of viral strain, clade, receptor binding properties, low- or high-pathogenicity cleavage site and glycosylation status. H5 HA genes were selected from nine known high-pathogenicity avian influenza subtype H5N1 viruses, based on their diversity in biologically significant regions of hemagglutinin and/or their ability to cause infection in humans. We devised a consensus pre-programmed pyrosequencing strategy, which may be used as a faster, more accurate alternative to de novo sequencing. The available data suggest that the assay described here is a reliable, rapid, information-rich and cost-effective approach for definitive diagnosis of H5N1 avian influenza. Knowledge of the predicted functional sequences of the HA will enhance H5N1 avian influenza surveillance efforts.

  11. Computerized tomography of gall bladder cancer

    International Nuclear Information System (INIS)

    Todua, F.I.; Karmazanovskij, G.G.

    1989-01-01

    The authors have summed up the experience in the use of computerized tomography (CT) in diagnosis of gall bladder cancer. The investigation of 17 patients with cancer of this site showed a high informative value of the method. A retrospective comparative study of the results of CT and surgical interventions was carried out. It has been concluded that CT makes it possible not only to diagnose malignant lesions of the bile ducts but also to assess a possible scope of a forthcoming operation

  12. Recurrent lymph node metastases after craniocervical tumours: Computerized tomography

    International Nuclear Information System (INIS)

    Helmberger, H.; Lenz, M.; Kersting-Sommerhoff, B.; Bautz, W.; Kretz, S.

    1992-01-01

    A total of 544 CT examinations of the craniocervical region carried out in 231 patients were analyzed on a retrospective basis in order to assess the clinical value of contrast-enhanced computerized tomography, being carried out either for comparison with or in combination with clinical control examinations, in the post-therapeutic surveillance of patients treated for craniocervical tumours. The diagnostic accuracy attained with computerized tomography in the detection of recurrent lymph node metastases was 95% and thus superior to that determined for clinical control examinations (80%). (orig./GDG) [de

  13. Computerized tomographic system

    International Nuclear Information System (INIS)

    Godbarsen, R.; Barrett, D.M.; Garrott, P.M.; Foley, L.E.; Redington, R.W.; Lambert, T.W.; Edelheit, L.S.

    1981-01-01

    A computerized tomographic system for examining human breasts is described in detail. Conventional X-ray scanning apparatus has difficulty in achieving the levels of image definition and examination speeds required for mass screening. A novel method of scanning successive layers of the breast with a rotating X-ray beam is discussed and details of the control circuitry and sequence steps are given. The method involves immersing the breast in an inner fluid (e.g. water) filled container which is stationary during an examination and is surrounded by a large outer container which is also filled with the fluid; the inner and outer containers are always maintained at a constant height and the X-ray absorption across the fan-shaped beam is as close as possible to constant. (U.K.)

  14. Computerized automated remote inspection system

    International Nuclear Information System (INIS)

    The automated inspection system utilizes a computer to control the location of the ultrasonic transducer, the actual inspection process, the display of the data, and the storage of the data on IBM magnetic tape. This automated inspection equipment provides two major advantages. First, it provides a cost savings, because of the reduced inspection time, made possible by the automation of the data acquisition, processing, and storage equipment. This reduced inspection time is also made possible by a computerized data evaluation aid which speeds data interpretation. In addition, the computer control of the transducer location drive allows the exact duplication of a previously located position or flaw. The second major advantage is that the use of automated inspection equipment also allows a higher-quality inspection, because of the automated data acquisition, processing, and storage. This storage of data, in accurate digital form on IBM magnetic tape, for example, facilitates retrieval for comparison with previous inspection data. The equipment provides a multiplicity of scan data which will provide statistical information on any questionable volume or flaw. An automatic alarm for location of all reportable flaws reduces the probability of operator error. This system has the ability to present data on a cathode ray tube as numerical information, a three-dimensional picture, or ''hard-copy'' sheet. One important advantage of this system is the ability to store large amounts of data in compact magnetic tape reels

  15. Diagnostic Strategy in APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongyoung; Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-05-15

    These features may bring out changes in operator tasks, changing the characteristics of tasks, or creating new tasks. Diagnostic strategy for identifying anomaly may be different especially in APR1400 from that in the analog control room due to the change of human-system interface, i.e. alarm system and display system. Since the first plant of APR1400 is being built at this moment, it is not known what strategies the operators will adopt in diagnosis tasks in the new operating environment. In this light, this paper aims at investigating operator's diagnostic strategies which are appropriate for APR1400. In order to collect data, several different approaches which are complementary are used to identify diagnostic strategies in the digital control room: analysis on audio/video recording of operation, observation in the simulator, and interview with the operators. The result shows that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of strategies, mostly, by getting more support from the computerized system. This paper investigated how the digitalized control room may influence operator's diagnostic strategies. Several different approaches, i. e., audio/video record, observation of training, and the interview with operators, were used to gather information about the operator's behaviors. As a conclusion, this paper figured out that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of the strategies, mostly, by getting more support from the computerized system. The operators interviewed also commented that the diagnosis in the APR1400 is quicker, more correct, and easier, compared with the analog control room.

  16. Diagnostic Strategy in APR1400

    International Nuclear Information System (INIS)

    Kim, Dongyoung; Kim, Jonghyun

    2013-01-01

    These features may bring out changes in operator tasks, changing the characteristics of tasks, or creating new tasks. Diagnostic strategy for identifying anomaly may be different especially in APR1400 from that in the analog control room due to the change of human-system interface, i.e. alarm system and display system. Since the first plant of APR1400 is being built at this moment, it is not known what strategies the operators will adopt in diagnosis tasks in the new operating environment. In this light, this paper aims at investigating operator's diagnostic strategies which are appropriate for APR1400. In order to collect data, several different approaches which are complementary are used to identify diagnostic strategies in the digital control room: analysis on audio/video recording of operation, observation in the simulator, and interview with the operators. The result shows that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of strategies, mostly, by getting more support from the computerized system. This paper investigated how the digitalized control room may influence operator's diagnostic strategies. Several different approaches, i. e., audio/video record, observation of training, and the interview with operators, were used to gather information about the operator's behaviors. As a conclusion, this paper figured out that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of the strategies, mostly, by getting more support from the computerized system. The operators interviewed also commented that the diagnosis in the APR1400 is quicker, more correct, and easier, compared with the analog control room

  17. Diagnostic information of TL-201 myocardial kinetics shortly after termination of exercise

    International Nuclear Information System (INIS)

    Wackers, F.J.; Fetterman, R.C.; Heitzman, M.; Clements, J.

    1984-01-01

    Traditionally, T1-201 stress imaging is performed immediately post exercise (EX) and 2-4 hrs later. This interval was chosen initially for visual comparison of T1-201 images and more recently for assessment of T1-201 washout (WO). Previously, the authors demonstrated that T1-201 kinetics shortly after EX are variable in patients (pts) with coronary artery disease (CAD). In this study, the authors evaluated the potential diagnostic information to be gained from analysis of early post EX T1-201 kinetics. In 70 pts, quantitative T1-201 stress imaging was performed. Sixteen pts were normal, 54 pts had CAD by angiography. All pts had symptom-limited EX. Serial LAO imaging was performed: 1) 5 min post EX; 2) 30 min post EX; 3) 2 hrs post EX. After interpolative background correction, circumferential WO profiles were generated. All normals had WO of T1-201 at 30 min post EX (average WO 14%). In contrast, 21 (39%) of pts with CAD had accumulation of T1-201, 5 (9%) had no change and 28 (52%) had WO at 30 min post EX. Between 30 min and 2 hrs post EX, 50 of 54 (93%) pts with CAD had WO. At 2 hrs, compared to 5 min post EX, 39 (72%) of pts with CAD had abnormal low WO (<30%) including all 21 with initial accumulation and 3 of 5 with initially no change of T1-201. Thus, whereas at 2 hrs post EX 72% of pts with CAD are abnormal by degree of WO, at 30 min post EX 48% are abnormal by direction of T1-201 kinetics. Continued increase of T1-201 at 30 min post EX is highly specific for CAD, although less sensitive than abnormal WO at 2 hrs post EX. Nevertheless, T1-201 kinetics shortly post EX contribute useful diagnostic information that may enhance reliability and confidence in interpretation of quantitative T1-201 analysis

  18. Computerized radiation treatment planning

    International Nuclear Information System (INIS)

    Laarse, R. van der.

    1981-01-01

    Following a general introduction, a chain consisting of three computer programs which has been developed for treatment planning of external beam radiotherapy without manual intervention is described. New score functions used for determination of optimal incidence directions are presented and the calculation of the position of the isocentre for each optimum combination of incidence directions is explained. A description of how a set of applicators, covering fields with dimensions of 4 to 20 cm, for the 6 to 20 MeV electron beams of a MEL SL75-20 linear accelerator was developed, is given. A computer program for three dimensional electron beam treatment planning is presented. A microprocessor based treatment planning system for the Selectron remote controlled afterloading system for intracavitary radiotherapy is described. The main differences in treatment planning procedures for external beam therapy with neutrons instead of photons is discussed. A microprocessor based densitometer for plotting isodensity lines in film dosimetry is described. A computer program for dose planning of brachytherapy is presented. Finally a general discussion about the different aspects of computerized treatment planning as presented in this thesis is given. (Auth.)

  19. Radioactive waste computerized management

    International Nuclear Information System (INIS)

    Communaux, M.; Lantes, B.

    1993-01-01

    Since December 31, 1990, the management of the nuclear wastes for all the power stations has been computerized, using the DRA module of the Power Generation and Transmission Group's data processing master plan. So now EDF has a software package which centralizes all the data, enabling it to declare the characteristics of the nuclear wastes which are to be stored on the sites operated by the National Radioactive Waste Management Agency (ANDRA). Among other uses, this application makes it possible for EDF, by real time data exchange with ANDRA, to constitute an inventory of validated, shippable packs. It also constitutes a data base for all the wastes produced on the various sites. This application was developed to meet the following requirements: give the producers of radioactive waste a means to fully manage all the characteristics and materials that are necessary to condition their waste correctly; guarantee the traceability and safety of data and automatically assure the transmission of this data in real time between the producers and the ANDRA; give the Central Services of EDF an operation and statistical tool permitting an experienced feed-back based on the complete national production (single, centralized data base); and integrate the application within the products of the processing master plan in order to assure its maintenance and evolution

  20. Unrequested information from routine diagnostic chest CT predicts future cardiovascular events

    International Nuclear Information System (INIS)

    Jacobs, Peter C.; Gondrie, Martijn J.; Grobbee, Diederick E.; Graaf, Yolanda van der; Mali, Willem P.; Oen, Ayke L.; Prokop, Mathias

    2011-01-01

    An increase in the number of CT investigations will likely result in a an increase in unrequested information. Clinical relevance of these findings is unknown. This is the first follow-up study to investigate the prognostic relevance of subclinical coronary (CAC) and aortic calcification (TAC) as contained in routine diagnostic chest CT in a clinical care population. The follow-up of 10,410 subjects (>40 years) from a multicentre, clinical care-based cohort of patients included 240 fatal to 275 non-fatal cardiovascular disease (CVD) events (mean follow-up 17.8 months). Patients with a history of CVD were excluded. Coronary (0-12) and aortic calcification (0-8) were semi-quantitatively scored. We used Cox proportional-hazard models to compute hazard ratios to predict CVD events. CAC and TAC were significantly and independently predictive of CVD events. Compared with subjects with no calcium, the adjusted risk of a CVD event was 3.7 times higher (95% CI, 2.7-5.2) among patients with severe coronary calcification (CAC score ≥6) and 2.7 times higher (95% CI, 2.0-3.7) among patients with severe aortic calcification (TAC score ≥5). Subclinical vascular calcification on CT is a strong predictor of incident CVD events in a routine clinical care population. (orig.)

  1. Validation of diabetes mellitus and hypertension diagnosis in computerized medical records in primary health care

    Directory of Open Access Journals (Sweden)

    Abánades-Herranz Juan C

    2011-10-01

    Full Text Available Abstract Background Computerized Clinical Records, which are incorporated in primary health care practice, have great potential for research. In order to use this information, data quality and reliability must be assessed to prevent compromising the validity of the results. The aim of this study is to validate the diagnosis of hypertension and diabetes mellitus in the computerized clinical records of primary health care, taking the diagnosis criteria established in the most prominently used clinical guidelines as the gold standard against which what measure the sensitivity, specificity, and determine the predictive values. The gold standard for diabetes mellitus was the diagnostic criteria established in 2003 American Diabetes Association Consensus Statement for diabetic subjects. The gold standard for hypertension was the diagnostic criteria established in the Joint National Committee published in 2003. Methods A cross-sectional multicentre validation study of diabetes mellitus and hypertension diagnoses in computerized clinical records of primary health care was carried out. Diagnostic criteria from the most prominently clinical practice guidelines were considered for standard reference. Sensitivity, specificity, positive and negative predictive values, and global agreement (with kappa index, were calculated. Results were shown overall and stratified by sex and age groups. Results The agreement for diabetes mellitus with the reference standard as determined by the guideline was almost perfect (κ = 0.990, with a sensitivity of 99.53%, a specificity of 99.49%, a positive predictive value of 91.23% and a negative predictive value of 99.98%. Hypertension diagnosis showed substantial agreement with the reference standard as determined by the guideline (κ = 0.778, the sensitivity was 85.22%, the specificity 96.95%, the positive predictive value 85.24%, and the negative predictive value was 96.95%. Sensitivity results were worse in patients who

  2. Risk-adjusted capitation based on the Diagnostic Cost Group Model: an empirical evaluation with health survey information

    NARCIS (Netherlands)

    L.M. Lamers (Leida)

    1999-01-01

    textabstractOBJECTIVE: To evaluate the predictive accuracy of the Diagnostic Cost Group (DCG) model using health survey information. DATA SOURCES/STUDY SETTING: Longitudinal data collected for a sample of members of a Dutch sickness fund. In the Netherlands the sickness

  3. Effects of Diagnostic Label and Disease Information on Emotions, Beliefs, and Willingness to Help Older Parents with Osteoarthritis

    Science.gov (United States)

    Thomas, Kali S.; McIlvane, Jessica M.; Haley, William E.

    2012-01-01

    We studied the impact of the diagnostic label of osteoarthritis and educational information on family members' attributions, perceptions, and willingness to help older parents with pain. Undergraduate students (N = 636) were randomly assigned to one of three conditions where they read vignettes about an older mother with chronic pain, which varied…

  4. Integrating Research-Informed Teaching within an Undergraduate Level 4 (Year 1) Diagnostic Radiography Curriculum: A Pilot Study

    Science.gov (United States)

    Higgins, Robert; Hogg, Peter; Robinson, Leslie

    2013-01-01

    This article discusses the piloting and evaluation of the Research-informed Teaching experience (RiTe) project. The aim of RiTe was to link teaching and learning with research within an undergraduate diagnostic radiography curriculum. A preliminary pilot study of RiTe was undertaken with a group of level 4 (year 1) volunteer BSc (Hons) diagnostic…

  5. Early evaluation of a second generation information monitoring and diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Kinney, Satkartar; Bourassa, Norman; Xu, Peng; Haves, Philip; Kinney, Kristopher; Shockman, Christine

    2002-03-25

    Private sector commercial office buildings are challenging environments for energy efficiency projects. This challenge is related to the complexity of business environments that involve ownership, operation, and tenant relationships. Whether it is poor quality design, inefficient operations, degradation of equipment over time, or merely the increasing use of energy by tenants and inattention from landlords, commercial office building energy use continues to increase. This research project was developed to examine the environment for building operations and identify causes of inefficient use of energy related to technical and organizational issues. This report discusses a second-generation Information Monitoring and Diagnostic System (IMDS) installed at a leased office building in Sacramento, California. The report begins with a brief summary of the IMDS research at the previous building, followed by a discussion of the building selection process, the IMDS design and installation, recent use of the IMDS, costs and benefits, and fault detection and diagnostic research using the IMDS. A web site describes the IMDS in detail (see imds.lbl.gov). The underlying principle of this research project is that high quality building performance data can help show where energy is being used and how buildings systems actually perform is an important first step toward improving building energy efficiency. The project utilizes a high-quality monitoring system that has been developed during the past decade by a partnership between LBNL and private industry. This research project has been successful in demonstrating that the IMDS is tremendously valuable to the building operators at the Sacramento site. The building operators not only accept the technology, but it has become the core of their day-to-day building control concepts. The innovative property management company, Jones Lang LaSalle, is interested in installing more sites to determine if the system could provide an economic

  6. Computerized data treatment technology

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Maddox, J.H.; Wren, H.F.

    1977-01-01

    The Savannah River Laboratory (SRL) has accepted responsibility for a hydrogeochemical and stream-sediment reconnaissance in 25 eastern states as part of the National Uranium Resource Evaluation (NURE). SRL has developed a computerized program for recording, processing, updating, retrieving, and analyzing hydrogeochemical data from this reconnaissance. This program will handle an expected 150 million bytes of hydrogeochemical data from 150,000 to 200,000 sample sites over the next four years. The SRL--NURE hydrogeochemical data management system is written in FORTRAN IV for an IBM System 360/195 computer and is designed to easily accommodate changes in types of collected data and input format. As the data become available, they are accepted and combined with relevant data already in the system. SRL also developed a sample inventory and control system and a graphics and analysis system. The sample inventory and control system accounts for the movements of all samples and forms from initial receipt through final storage. Approximately six million sample movements are expected. The graphics and analysis system provides easily usable programs for reporting and interpreting data. Because of the large volume of data to be interpreted, the graphics and analysis system plays a central role in the hydrogeochemical program. Programs developed to provide two- and three-dimensional plots of sampled geographic areas show concentrations and locations of individual variables which are displayed and reproduced photographically. Pattern recognition techniques are also available, and they allow multivariate data to be categorized into ''clusters,'' which may indicate sites favorable for uranium exploration

  7. Patient surface doses in computerized tomography examinations

    International Nuclear Information System (INIS)

    Vekic, B; Kovacevic, S.; Ranogajec-Komor, M.; Duvnjak, N.; Marusic, P.; Anic, P.; Dolencic, P.

    1996-01-01

    The diagnostic value of computerized tomography has increased due to very rapid technical advances in both equipment and techniques. When the CT scanners were introduced, a significant problem for the specification of the radiation dose imparted to the patient undergoing CT examination has been created. In CT, the conditions of exposure are quite different from those in conventional X-ray imaging. CT procedure involves the continuous tomography of thin layers. Some of these layers touch each other while others overlap. The radiation doses received by patients can vary considerably. In addition to the radiation from the collimated primary beam, patients are exposed to significant scattered doses in unpredictable amounts. Every effort should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The aims of this work were to determine the surface doses delivered to various organs of patients during various computerized tomography examinations (head, thorax, kidney, abdomen and pelvis). Particular attention was directed to the precise determination of doses received by the eyes (during CT of head) and gonads (during CT of pelvis and lower abdomen) since these organs can be near or even in the primary X-ray beam

  8. Performance assessment and adoption processes of an information monitoring and diagnostic system prototype; FINAL

    International Nuclear Information System (INIS)

    Piette, Mary Ann

    1999-01-01

    This report addresses the problem that buildings do not perform as well as anticipated during design. We partnered with an innovative building operator to evaluate a prototype Information Monitoring and Diagnostic System (IMDS). The IMDS consists of high-quality measurements archived each minute, a data visualization tool, and a web-based capability. The operators recommend similar technology be adopted in other buildings. The IMDS has been used to identify and correct a series of control problems. It has also allowed the operators to make more effective use of the building control system, freeing up time to take care of other tenant needs. They believe they have significantly improved building comfort, potentially improving tenant health, and productivity. The reduction in hours to operate the building are worth about$20,000 per year, which could pay for the IMDS in about five years. A control system retrofit based on findings from the IMDS is expected to reduce energy use by 20 percent over the next year, worth over$30,000 per year. The main conclusion of the model-based chiller fault detection work is that steady-state models can be used as reference models to monitor chiller operation and detect faults. The ability of the IMDS to measure cooling load and chiller power to one-percent accuracy with a one-minute sampling interval permits detection of additional faults. Evolutionary programming techniques were also evaluated, showing promise in the detection of patterns in building data. We also evaluated two technology adoption processes, radical and routine. In routine adoption, managers enhance features of existing products that are already well understood. In radical adoption, innovative building managers introduce novel technology into their organizations without using the rigorous payback criteria used in routine innovations

  9. Performance assessment and adoption processes of an information monitoring and diagnostic system prototype

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann

    1999-10-01

    This report addresses the problem that buildings do not perform as well as anticipated during design. We partnered with an innovative building operator to evaluate a prototype Information Monitoring and Diagnostic System (IMDS). The IMDS consists of high-quality measurements archived each minute, a data visualization tool, and a web-based capability. The operators recommend similar technology be adopted in other buildings. The IMDS has been used to identify and correct a series of control problems. It has also allowed the operators to make more effective use of the building control system, freeing up time to take care of other tenant needs. They believe they have significantly improved building comfort, potentially improving tenant health, and productivity. The reduction in hours to operate the building are worth about $20,000 per year, which could pay for the IMDS in about five years. A control system retrofit based on findings from the IMDS is expected to reduce energy use by 20 percent over the next year, worth over $30,000 per year. The main conclusion of the model-based chiller fault detection work is that steady-state models can be used as reference models to monitor chiller operation and detect faults. The ability of the IMDS to measure cooling load and chiller power to one-percent accuracy with a one-minute sampling interval permits detection of additional faults. Evolutionary programming techniques were also evaluated, showing promise in the detection of patterns in building data. We also evaluated two technology adoption processes, radical and routine. In routine adoption, managers enhance features of existing products that are already well understood. In radical adoption, innovative building managers introduce novel technology into their organizations without using the rigorous payback criteria used in routine innovations.

  10. Relative performance of commonly used physical function questionnaires in rheumatoid arthritis and a patient-reported outcomes measurement information system computerized adaptive test

    NARCIS (Netherlands)

    Oude Voshaar, Antonius H.; ten Klooster, Peter M.; Glas, Cornelis A.W.; Vonkeman, Harald Erwin; Krishnan, Eswar; van de Laar, Mart A F J

    2014-01-01

    OBJECTIVE: To evaluate and compare the measurement precision and sensitivity to change of the Health Assessment Questionnaire disability index (HAQ DI), the Short Form 36 physical functioning scale (PF-10), and simulated Patient-Reported Outcomes Measurement Information System (PROMIS) physical

  11. Usability of computerized nursing process from the ICNP® in intensive care units

    Directory of Open Access Journals (Sweden)

    Daniela Couto Carvalho Barra

    2015-04-01

    Full Text Available OBJECTIVE To analyze the usability of Computerized Nursing Process (CNP from the ICNP® 1.0 in Intensive Care Units in accordance with the criteria established by the standards of the International Organization for Standardization and the Brazilian Association of Technical Standards of systems. METHOD This is a before-and-after semi-experimental quantitative study, with a sample of 34 participants (nurses, professors and systems programmers, carried out in three Intensive Care Units. RESULTS The evaluated criteria (use, content and interface showed that CNP has usability criteria, as it integrates a logical data structure, clinical assessment, diagnostics and nursing interventions. CONCLUSION The CNP is a source of information and knowledge that provide nurses with new ways of learning in intensive care, for it is a place that provides complete, comprehensive, and detailed content, supported by current and relevant data and scientific research information for Nursing practices.

  12. Benefits of a relational database for computerized management

    International Nuclear Information System (INIS)

    Shepherd, W.W.

    1991-01-01

    This paper reports on a computerized relational database which is the basis for a hazardous materials information management system which is comprehensive, effective, flexible and efficient. The system includes product information for Material Safety Data Sheets (MSDSs), labels, shipping, and the environment and is used in Dowell Schlumberger (DS) operations worldwide for a number of programs including planning, training, emergency response and regulatory compliance

  13. Development of an Instrument to Measure Health Center (HC) Personnel's Computer Use, Knowledge and Functionality Demand for HC Computerized Information System in Thailand

    OpenAIRE

    Kijsanayotin, Boonchai; Pannarunothai, Supasit; Speedie, Stuart

    2005-01-01

    Knowledge about socio-technical aspects of information technology (IT) is vital for the success of health IT projects. The Thailand health administration anticipates using health IT to support the recently implemented national universal health care system. However, the national knowledge associate with the socio-technical aspects of health IT has not been studied in Thailand. A survey instrument measuring Thai health center (HC) personnel’s computer use, basic IT knowledge a...

  14. Intelligent Information Retrieval: Diagnosing Information Need. Part II. Uncertainty Expansion in a Prototype of a Diagnostic IR Tool.

    Science.gov (United States)

    Cole, Charles; Cantero, Pablo; Sauve, Diane

    1998-01-01

    Outlines a prototype of an intelligent information-retrieval tool to facilitate information access for an undergraduate seeking information for a term paper. Topics include diagnosing the information need, Kuhlthau's information-search-process model, Shannon's mathematical theory of communication, and principles of uncertainty expansion and…

  15. Quality criteria for abdominal computerized tomography

    International Nuclear Information System (INIS)

    Huebener, K.H.; Kurtz, B.; Metzger, H.O.F.

    1985-01-01

    Quality, not only in obdominal computerized tomography, is determined by the measurable technical parameters and, to an important extent, also bei individual factors, among which the diagnostic skill and experience of the examiner is one of the most decisive. These individual factors and the part they play with regard to the quality of CT-assisted diagnosis may well equal the technical parameters, as they significantly influence the course of examinations, resulting indications for contrast medium application, and the sensitivity of the diagnosis. The authors are convinced that especially for abdominal CT, standardized examination techniques inevitably would bring down the diagnostic quality. The technical parameters are of equal significance to achieving the diagnostic optimum, and to these parameters one has to count equipment characteristics as well as the data given by the examiner. Exposure time, spatial resolution and density differentiation are given by the equipment specifications but have to be adapted to and optimised to the clinical problems involved in every case. Another important task is that of routine imaging of given anatomic structures, for adequate evaluation of individual conditions. (orig./MG) [de

  16. Validation of Patient-Reported Outcomes Measurement Information System Computerized Adaptive Tests Against the Foot and Ankle Outcome Score for 6 Common Foot and Ankle Pathologies.

    Science.gov (United States)

    Koltsov, Jayme C B; Greenfield, Stephen T; Soukup, Dylan; Do, Huong T; Ellis, Scott J

    2017-08-01

    The field of foot and ankle surgery lacks a widely accepted gold-standard patient-reported outcome instrument. With the changing infrastructure of the medical profession, more efficient patient-reported outcome tools are needed to reduce respondent burden and increase participation while providing consistent and reliable measurement across multiple pathologies and disciplines. The primary purpose of the present study was to validate 3 Patient-Reported Outcomes Measurement Information System computer adaptive tests (CATs) most relevant to the foot and ankle discipline against the Foot and Ankle Outcome Score (FAOS) and the Short Form 12 general health status survey in patients with 6 common foot and ankle pathologies. Patients (n = 240) indicated for operative treatment for 1 of 6 common foot and ankle pathologies completed the CATs, FAOS, and Short Form 12 at their preoperative surgical visits, 1 week subsequently (before surgery), and at 6 months postoperatively. The psychometric properties of the instruments were assessed and compared. The Patient-Reported Outcomes Measurement Information System CATs each took less than 1 minute to complete, whereas the FAOS took 6.5 minutes, and the Short Form 12 took 3 minutes. CAT scores were more normally distributed and had fewer floor and ceiling effects than those on the FAOS, which reached as high as 24%. The CATs were more precise than the FAOS and had similar responsiveness and test-retest reliability. The physical function and mobility CATs correlated strongly with the activities subscale of the FAOS, and the pain interference CAT correlated strongly with the pain subscale of the FAOS. The CATs and FAOS were responsive to changes with operative treatment for 6 common foot and ankle pathologies. The CATs performed as well as or better than the FAOS in all aspects of psychometric validity. The Patient-Reported Outcomes Measurement Information System CATs show tremendous potential for improving the study of patient

  17. Towards a Clinical Trial Protocol to Evaluate Health Information Systems: Evaluation of a Computerized System for Monitoring Tuberculosis from a Patient Perspective in Brazil.

    Science.gov (United States)

    Crepaldi, Nathalia Yukie; de Lima, Inacia Bezerra; Vicentine, Fernanda Bergamini; Rodrigues, Lídia Maria Lourençon; Sanches, Tiago Lara Michelin; Ruffino-Netto, Antonio; Alves, Domingos; Rijo, Rui Pedro Charters Lopes

    2018-05-08

    Assessment of health information systems consider different aspects of the system itself. They focus or on the professional who will use the software or on its usability or on the software engineering metrics or on financial and managerial issues. The existent approaches are very resources consuming, disconnected, and not standardized. As the software becomes more critical in the health organizations and in patients, becoming used as a medical device or a medicine, there is an urgency to identify tools and methods that can be applied in the development process. The present work is one of the steps of a broader study to identify standardized protocols to evaluate the health information systems as medicines and medical devices are evaluated by clinical trials. The goal of the present work was to evaluate the effect of the introduction of an information system for monitoring tuberculosis treatment (SISTB) in a Brazilian municipality from the patients' perspective. The Patient Satisfaction Questionnaire and the Hospital Consumer Assessment of Healthcare Providers and Systems were answered by the patients before and after the SISTB introduction, for comparison. Patients from an outpatient clinic, formed the control group, that is, at this site was not implanted the SISTB. Descriptive statistics and mixed effects model were used for data analysis. Eighty-eight interviews were conducted in the study. The questionnaire's results presented better averages after the system introduction but were not considered statistically significant. Therefore, it was not possible to associate system implantation with improved patient satisfaction. The HIS evaluation need be complete, the technical and managerial evaluation, the safety, the impact on the professionals and direct and/or indirect impact on patients are important. Developing the right tools and methods that can evaluate the software in its entirety, from the beginning of the development cycle with a normalized scale, are

  18. 45 CFR 307.13 - Security and confidentiality for computerized support enforcement systems in operation after...

    Science.gov (United States)

    2010-10-01

    ... ENFORCEMENT SYSTEMS § 307.13 Security and confidentiality for computerized support enforcement systems in... systems in operation after October 1, 1997. (a) Information integrity and security. Have safeguards... 45 Public Welfare 2 2010-10-01 2010-10-01 false Security and confidentiality for computerized...

  19. Computerized information system of support to the electric energy losses control; Sistema de informacion computarizado de apoyo al control de perdidas de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Barba Mar, Alvaro R; Perez Ortega, Joaquin; Rodriguez Ortiz, Guillermo; Rodriguez Cano, Rene; Zapata Garcia, Juan Antonio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The energy losses are due to several reasons, among others, to the same nature of the generation, transmission, and distribution processes. The purpose of this paper is to describe in a general manner a decentralized system that processes the information of the energy and demand meters, to obtain the energy balances and losses indexes at national level. Additionally, the main services offered by the functional model and of the data base, the adopted policies for the energy interchanges among responsibility areas and the concepts of use, are described; next, the data sources of the system are described, the fragmentation and corresponding replication to the database are described and its architecture of software and hardware is shown. [Espanol] Las perdidas de energia se deben a varias razones, entre otras, a la naturaleza misma de los procesos de generacion, transmision y distribucion de la electricidad. El proposito de este articulo es describir de manera general un sistema descentralizado que procesa la informacion de los medidores de energia y demanda, para la obtencion de balances de energia e indices de perdidas a nivel nacional. Ademas, se describen los principales servicios que ofrece, el modelo funcional y el de la base de datos, las politicas adoptadas para los intercambios de energia entre areas de responsabilidad y los conceptos de uso; despues se describen las fuentes de datos del sistema, la fragmentacion y replicacion correspondiente a la base de datos y se muestra su arquitectura de hardware y software.

  20. Computerized information system of support to the electric energy losses control; Sistema de informacion computarizado de apoyo al control de perdidas de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Barba Mar, Alvaro R.; Perez Ortega, Joaquin; Rodriguez Ortiz, Guillermo; Rodriguez Cano, Rene; Zapata Garcia, Juan Antonio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    The energy losses are due to several reasons, among others, to the same nature of the generation, transmission, and distribution processes. The purpose of this paper is to describe in a general manner a decentralized system that processes the information of the energy and demand meters, to obtain the energy balances and losses indexes at national level. Additionally, the main services offered by the functional model and of the data base, the adopted policies for the energy interchanges among responsibility areas and the concepts of use, are described; next, the data sources of the system are described, the fragmentation and corresponding replication to the database are described and its architecture of software and hardware is shown. [Espanol] Las perdidas de energia se deben a varias razones, entre otras, a la naturaleza misma de los procesos de generacion, transmision y distribucion de la electricidad. El proposito de este articulo es describir de manera general un sistema descentralizado que procesa la informacion de los medidores de energia y demanda, para la obtencion de balances de energia e indices de perdidas a nivel nacional. Ademas, se describen los principales servicios que ofrece, el modelo funcional y el de la base de datos, las politicas adoptadas para los intercambios de energia entre areas de responsabilidad y los conceptos de uso; despues se describen las fuentes de datos del sistema, la fragmentacion y replicacion correspondiente a la base de datos y se muestra su arquitectura de hardware y software.

  1. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Additional information

    International Nuclear Information System (INIS)

    2009-03-01

    The reports from Argentina, Canada, India, Korea and Romania are presented concerning the projects carried out under the Coordinated Research Program (CRP) I3.30.10 of the International Agency for Atomic Energy - Vienna related to 'Intercomparison of Techniques for Pressure Tube Inspection and Diagnostics'

  2. Computerized Proof Techniques for Undergraduates

    Science.gov (United States)

    Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu

    2012-01-01

    The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete…

  3. Computerized adaptive testing in computer assisted learning?

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; Eggen, Theodorus Johannes Hendrikus Maria; De Wannemacker, Stefan; Clarebout, Geraldine; De Causmaecker, Patrick

    2011-01-01

    A major goal in computerized learning systems is to optimize learning, while in computerized adaptive tests (CAT) efficient measurement of the proficiency of students is the main focus. There seems to be a common interest to integrate computerized adaptive item selection in learning systems and

  4. Technologies in Computerized Lexicography

    African Journals Online (AJOL)

    guage technology, information technology and knowledge engineering, may .... character recognition (OCR) with computer-aided correction (Kruyt and Van ..... encoded for headword and part of speech by linguistic software developed at.

  5. Modernizing computerized nuclear material accounting systems

    International Nuclear Information System (INIS)

    Erkkila, B.H.; Claborn, J.

    1995-01-01

    DOE Orders and draft orders for nuclear material control and accountability address a complete material control and accountability (MC and A) program for all DOE contractors processing, using, or storing nuclear materials. A critical element of an MC and A program is the accounting system used to track and record all inventories of nuclear material and movements of materials in those inventories. Most DOE facilities use computerized accounting systems to facilitate the task of accounting for all their inventory of nuclear materials. Many facilities still use a mixture of a manual paper system with a computerized system. Also, facilities may use multiple systems to support information needed for MC and A. For real-time accounting it is desirable to implement a single integrated data base management system for a variety of users. In addition to accountability needs, waste management, material management, and production operations must be supported. Information in these systems can also support criticality safety and other safety issues. Modern networked microcomputers provide extensive processing and reporting capabilities that single mainframe computer systems struggle with. This paper describes an approach being developed at Los Alamos to address these problems

  6. Motivation and challenges for use of malaria rapid diagnostic tests among informal providers in Myanmar: a qualitative study.

    Science.gov (United States)

    Sudhinaraset, May; Briegleb, Christina; Aung, Moe; Khin, Hnin Su Su; Aung, Tin

    2015-02-06

    Rapid diagnostic tests (RDTs) for malaria enable proper diagnosis and have been shown to reduce overuse of artemisinin combination therapy. Few studies have evaluated the feasibility and use of RDTs in the private sector in Myanmar. The objectives of the study were to: 1) understand the acceptability of using RDTs in the informal sector in Myanmar; 2) examine motivations for use among informal providers; and, 3) highlight decision-making and knowledge of providers for diagnostic testing and treatment. Qualitative interviews were conducted with 30 informal providers. Purposeful sampling was used to enrol study participants in the Mon and Shan State in Myanmar. All interviews were conducted in Burmese, translated into English, and two researchers coded all interviews using Atlas ti. Major themes identified included: 1) informal provider and outlet characteristics, including demographic and background characteristics; 2) the benefits and challenges of using RDTs according to providers; 3) provider experiences with using RDTs, including motivations for using the RDT; 4) adherence to test results, either positive or negative; and, 5) recommendations from informal providers to promote increased use of RDTs in their communities. This study found that introducing RDTs to informal providers in Myanmar was feasible, resulting in improved provider empowerment and patient-provider relationships. Specific challenges included facility infrastructure to use and dispose RDTs and provider knowledge. This varied across the type of informal provider, with itinerant drug vendors more comfortable and knowledgeable about RDTs compared to general retail sellers and medical drug representatives. This study found informal providers in Myanmar found the introduction of RDTs to be highly acceptable. Providers discussed improvement in service quality including provider empowerment and patient-provider relationships. The study also highlighted a number of challenges that informal providers

  7. A Computerized Procedure linked to Virtual Equipment

    International Nuclear Information System (INIS)

    Jung, Yeon Sub; Song, Tae Young

    2011-01-01

    Digital, information, and communication technologies have change human's behavior. This is because human has limitation to memorize and process information. Human has to access other information and real time information for important decisions. Those technologies are playing important roles. Nuclear power plants cannot be exception. Many accidents in nuclear power plants result from absent or incorrect information. The information for nuclear personnel is context sensitive. They don't have enough time to verify the context sensitive information. Therefore they skip the information, as resulting in incident. Nuclear personnel are usually carrying static paper procedures during local task performance. The procedure guides them steps to follow. There is, however, no dynamic and context sensitive information in the paper. The effect of the work is evaluated once while getting permission of the work. Afterward they are not informed. The static paper is generally simplified, so that it does not show detail of equipment being manipulated. Particularly novice workers feel difficult to understand the procedure due to lack of detail. Pictures of equipment inserted in the procedure are not enough for comprehension. A computerized procedure linked with virtual equipment is one of the best solutions to increase the detail of procedure. Virtual equipment, however, has still limitation not to provide real time information, because the virtual equipment is not synchronized with real plants

  8. NRC Information Notice No. 93-01: Accuracy of motor-operated valve diagnostic equipment manufactured by Liberty Technologies

    International Nuclear Information System (INIS)

    Grimes, B.K.

    1993-01-01

    Most licensees rely on MOV diagnostic equipment to provide information on the thrust delivered by the motor actuator in opening or closing its valve. The various types of MOV diagnostic equipment estimate valve stem thrust using different parameters, such as displacement of the spring pack or strain in the stem, mounting bolts, or yoke. Liberty Technologies has developed MOV diagnostic equipment, referred to as the Valve Operation Test and Evaluation System (VOTES), that estimates the thrust needed to open or close a valve based on strain of the valve yoke. The VOTES equipment derives thrust from yoke strain that has been calibrated to stem thrust using measured diametral strain of the valve stem and nominal engineering material properties. On October 2, 1992, Liberty Technologies notified the NRC that it had determined that two new factors can affect the thrust values obtained with its equipment. Those factors involve (1) the possible use of improper stem material constants and (2) the failure to account for a torque effect when the VOTES equipment is calibrated by measuring strain in the threaded portion of the valve stem. Liberty Technologies provided information on performing manual calculations to address these factors and stated that its new software, Version 2.3, assists in performing corrections to the thrust data

  9. Quality criteria in computerized tomography of the chest

    International Nuclear Information System (INIS)

    Doehring, W.

    1985-01-01

    The quality of thoracical computerized tomography (CT) - like any other CT examination - depends from the quality of the equipment used, from the skill of the examinor and the properties of the patient. Concerning computerized chest tomograms, rapid scan equipment should be used only and slow translation - rotation systems should not be used any more. Whereas the quality of computerized tomograms may be influenced by the patient in the scanning process only, the examining physician will decisively influence the possible informative value of the examination also in the reconstruction of the CT value matrix, in single demonstration of CT values and, possibly, in additional measurement value processing as well as in the interpretation of findings. Use of equipment should always consider the technical potential provided by the equipment to be oriented to the clinical issue, and the conditions preset by the patient. (orig.) [de

  10. Cognitive task analysis and the design of computerized operator aids

    International Nuclear Information System (INIS)

    Andersson, H.

    1985-01-01

    The new technological possibilities have led to the initiation of many projects for the design and evaluation of computerized operator support systems to be implemented in nuclear power plant control rooms. A typical finding so far has been that operators often have a positive attitude towards such systems but still don't use them very much, mostly because they find almost the same information on the conventional control boards which they are accustomed to use. Still, however, there is a widely shared belief that conventional control rooms have short-comings that make the use of computerized aids necessary. One reason for the limited success so far is that the new systems often are poorly integrated with the existing conventional instrumentation and with the working procedures. The reluctance to use new computer based aids, despite their nice features, is therefore probably caused by an inadequate task analysis made prior to the design of these computerized operator support systems

  11. Computerized tomography in the examination of the orbit

    International Nuclear Information System (INIS)

    Ammerich, H.; Wackenheim, A.; Golabek, R.

    1980-01-01

    The importance of computerized tomography in the ophtalmological diagnosis is discussed. A great value of the information obtained by this not cumbersome method is stressed. The findings achieved this method in the most frequent diseases of the eyeball, orbit and neighbouring anatomical structures are described. (author)

  12. Robinson's computerized model of eye muscle mechanics revised.

    NARCIS (Netherlands)

    H.J. Simonsz (Huib)

    1994-01-01

    textabstractThe computerized model of static eye-muscle mechanics developed by Robinson was revised extensively and improved. An extensive literature study yielded additional information on the average diameter of the eye as related to age, on the average location of the insertions and origins of

  13. Computerized spirography and roentgenopneumopolygraphy in diagnosis of tracheobroncheal dyskinesia

    International Nuclear Information System (INIS)

    Gladkij, A.V.; Gul'ko, S.I.; Vyalyj, N.P.; Salivon, A.P.; Orlovskaya, I.I.

    1991-01-01

    The results of comprehensive examination of respiratory organs in 103 patients with hypotonic dyskinesia syndrome of trachea and large bronchi were presented. The comprehensive examination included computerized spirography and roentgenopneumopolygraphy with additional tests: exercise and drug. It was shown that the conducted comprehensive examination helped to receive an information about breathh physiology, to diagnose tracheobroncheal dyskinesia and to evaluate the degree of ventilation disorders

  14. Health Risks of Diagnostic Radiology

    International Nuclear Information System (INIS)

    Al-Oraby, M.N.A.

    2014-01-01

    Exposure to ionizing radiation during diagnostic radiologic procedures carries small but real risks. Children, young adults and pregnant women are especially vulnerable. Exposure of patients to diagnostic energy levels of ionizing radiation should be kept to the minimum necessary to provide useful clinical information and allay patients concerns about radiation-related risks. Computerized Tomography (CT) accounts for two thirds of the cumulative patient dose from diagnostic radiological procedures and the cumulative dose from CT is rising as technological advances increase the number of indications and the capabilities of CT. Carcinogenesis and teratogenesis are the main concerns with ionizing radiation. The risk increases as the radiation dose increases. There is no minimum threshold and the risk is cumulative: a dose of 1 mSv once a year for 10 years is equivalent to a single dose of 10 mSv. Whenever practical, choose an imaging test that uses less radiation or no radiation and lengthen the periods between follow-up imaging tests. Some patients may avoid screening mammography because of fear of radiation-induced cancer, yet this test uses a very small radiation dose (0.6 mSv, much less than the annual dose from background radiation, 3.6 mSv). (author)

  15. Computerized and Networked Government Information Column

    Science.gov (United States)

    Stratford, Juri

    2004-01-01

    The efforts of the U.S. federal government to develop E-Government services have been the subject of many recent news stories. In February 2002, Arthur Andersen's Office of Government Services released a usability analysis of federal government Web sites. In addition, in February, Vice-President Cheney announced the release of a report detailing…

  16. Health-based risk adjustment: is inpatient and outpatient diagnostic information sufficient?

    Science.gov (United States)

    Lamers, L M

    Adequate risk adjustment is critical to the success of market-oriented health care reforms in many countries. Currently used risk adjusters based on demographic and diagnostic cost groups (DCGs) do not reflect expected costs accurately. This study examines the simultaneous predictive accuracy of inpatient and outpatient morbidity measures and prior costs. DCGs, pharmacy cost groups (PCGs), and prior year's costs improve the predictive accuracy of the demographic model substantially. DCGs and PCGs seem complementary in their ability to predict future costs. However, this study shows that the combination of DCGs and PCGs still leaves room for cream skimming.

  17. A prototype of a computerized patient record.

    Science.gov (United States)

    Adelhard, K; Eckel, R; Hölzel, D; Tretter, W

    1995-01-01

    Computerized medical record systems (CPRS) should present user and problem oriented views of the patient file. Problem lists, clinical course, medication profiles and results of examinations have to be recorded in a computerized patient record. Patient review screens should give a synopsis of the patient data to inform whenever the patient record is opened. Several different types of data have to be stored in a patient record. Qualitative and quantitative measurements, narratives and images are such examples. Therefore, a CPR must also be able to handle these different data types. New methods and concepts appear frequently in medicine. Thus a CPRS must be flexible enough to cope with coming demands. We developed a prototype of a computer based patient record with a graphical user interface on a SUN workstation. The basis of the system are a dynamic data dictionary, an interpreter language and a large set of basic functions. This approach gives optimal flexibility to the system. A lot of different data types are already supported. Extensions are easily possible. There is also almost no limit concerning the number of medical concepts that can be handled by our prototype. Several applications were built on this platform. Some of them are presented to exemplify the patient and problem oriented handling of the CPR.

  18. Computerized radionuclidic analysis in production facilities

    International Nuclear Information System (INIS)

    Gibbs, A.

    1978-03-01

    The Savannah River Plant Laboratories Department has been using a dual computer system to control all radionuclidic pulse height analyses since 1971. This computerized system analyzes 7000 to 8000 samples per month and has allowed the counting room staff to be reduced from three persons to one person. More reliable process information is being returned to the production facilities and for environmental evaluations and being returned faster, even though the sample load has more than tripled. This information is now more easily retrievable for other evaluations. The computer is also used for mass spectrometer data reduction and for quality control data analysis. The basic system is being expanded by interfacing microcomputers which provide data input from all of the laboratory modules for quality assurance programs

  19. Computerized ECT data analysis system

    International Nuclear Information System (INIS)

    Miyake, Y.; Fukui, S.; Iwahashi, Y.; Matsumoto, M.; Koyama, K.

    1988-01-01

    For the analytical method of the eddy current testing (ECT) of steam generator tubes in nuclear power plants, the authors have developed the computerized ECT data analysis system using a large-scale computer with a high-resolution color graphic display. This system can store acquired ECT data up to 15 steam generators, and ECT data can be analyzed immediately on the monitor in dialogue communication with a computer. Analyzed results of ECT data are stored and registered in the data base. This system enables an analyst to perform sorting and collecting of data under various conditions and obtain the results automatically, and also to make a plan of tube repair works. This system has completed the test run, and has been used for data analysis at the annual inspection of domestic plants. This paper describes an outline, features and examples of the computerized eddy current data analysis system for steam generator tubes in PWR nuclear power plants

  20. Informativity of proteinograms as a clinical-diagnostic test at dispoteinemia in the age aspect

    Directory of Open Access Journals (Sweden)

    R. F. Yeriomenko

    2017-02-01

    Full Text Available The article analyzed dates of the usefulness of proteinograms as a clinical diagnostic test at dysproteinemia in age aspect. Established that proteinograms has  differences that depending on age, so these aspects should be considered in the diagnosis of certain pathological conditions in different age groups. Studying of children’s proteinograms in various pathological conditions indicates the appropriate changes in the fractional part of albumin and globulin, that characterized the development of inflammation and destruction of connective tissue. Besides diagnostic tests that help in the diagnosis, determine the stage of disease and the effectiveness of therapy is to study proteins "acute phase" and rheumatoid factor. Established the feasibility of proteinograms on the studying of dysproteinemia in different pathological conditions in adult age. It is found correlation between changes in protein fractions and stage of pathological process in connective tissue diseases (rheumatoid arthritis and systemic lupus erythema. At skin diseases, urinary, respiratory and hepatobiliary systems were recorded proteinograms changes depending on the damage of a system. Analysis of the results allows more accurate founded the diagnosis, determine the stage of the pathological process and evaluate the effectiveness of the pharmacotherapy.

  1. Use of diagnostic information submitted to the United Kingdom Central Cardiac Audit Database: development of categorisation and allocation algorithms.

    Science.gov (United States)

    Brown, Kate L; Crowe, Sonya; Pagel, Christina; Bull, Catherine; Muthialu, Nagarajan; Gibbs, John; Cunningham, David; Utley, Martin; Tsang, Victor T; Franklin, Rodney

    2013-08-01

    To categorise records according to primary cardiac diagnosis in the United Kingdom Central Cardiac Audit Database in order to add this information to a risk adjustment model for paediatric cardiac surgery. Codes from the International Paediatric Congenital Cardiac Code were mapped to recognisable primary cardiac diagnosis groupings, allocated using a hierarchy and less refined diagnosis groups, based on the number of functional ventricles and presence of aortic obstruction. A National Clinical Audit Database. Patients Children undergoing cardiac interventions: the proportions for each diagnosis scheme are presented for 13,551 first patient surgical episodes since 2004. In Scheme 1, the most prevalent diagnoses nationally were ventricular septal defect (13%), patent ductus arteriosus (10.4%), and tetralogy of Fallot (9.5%). In Scheme 2, the prevalence of a biventricular heart without aortic obstruction was 64.2% and with aortic obstruction was 14.1%; the prevalence of a functionally univentricular heart without aortic obstruction was 4.3% and with aortic obstruction was 4.7%; the prevalence of unknown (ambiguous) number of ventricles was 8.4%; and the prevalence of acquired heart disease only was 2.2%. Diagnostic groups added to procedural information: of the 17% of all operations classed as "not a specific procedure", 97.1% had a diagnosis identified in Scheme 1 and 97.2% in Scheme 2. Diagnostic information adds to surgical procedural data when the complexity of case mix is analysed in a national database. These diagnostic categorisation schemes may be used for future investigation of the frequency of conditions and evaluation of long-term outcome over a series of procedures.

  2. A diagnostic of the strategy employed for communicating nuclear related information to Brazilian communities around uranium mining areas

    International Nuclear Information System (INIS)

    Ferrari Dias, Fabiana; Tirollo Taddei, Maria H.

    2008-01-01

    This paper presents a diagnostic of the strategy used by the Brazilian uranium mining industry to communicate nuclear related information to communities around a mining area. The uranium mining industry in Brazil, which is run by the government, has been concerned with communication issues for quite some time. The need to communicate became more apparent after new mining operations started in the Northern region of Brazil. The fact that the government does not have a clear communication guideline made the operators of the uranium mining industry aware of the increasing demand for establishment of a good relationship with several types of Stake holders as well as employment of personnel with experience in dealing with them. A diagnostic of the current communication situation in Brazil and an analysis of the approaches over the past years was done through interviews with employees of the mining industry and review of institutional communication materials. The results were discussed during a Consultant's Meeting organized by the IAEA 's Seibersdorf Laboratory in October 2007. The output of the meeting included an overview of modern communication strategies used by different countries and a suggestion for new uranium mining operations in developing or under developed countries. The strategy for communicating nuclear related information to Brazilian communities varied according to the influence of different Stake holder groups. One initiative worth mentioning was the creation of a Mobile Nuclear Information Thematic Room, which was installed in several locations. This project was seen as one of the main tools to relate to community. Many Stake holders were identified during the diagnostic phase in preparation for the IAEA 's meeting on communication strategy: children, NGOs (Non Government Organizations), local churches, media and internal Stake holders, among others. An initial evaluation showed that the perception of a neighbouring community regarding an uranium

  3. Diagnostic systems in nuclear power plants. Proceedings of a technical committee meeting. Working material

    International Nuclear Information System (INIS)

    1998-01-01

    Nuclear power industry has a quite long tradition in on-line diagnostic of mechanical components and a considerable effort was put in developing diagnostic systems which are able to detect arising mechanical problems at an early stage. Computers are increasingly exploited to provide higher level information on process behaviour such as: early indication of the process deviation from normal conditions; rapid identification of the cause of any disturbance; prediction of the evolution of a disturbance; operator aid through computerized help. Following the recommendation of Several Member States to strengthen the activity in this field two divisions of IAEA established in 1995 the International Task Force on Nuclear Power Plant Diagnostics. The scope of the task force cover both technological developments and safety/licensing aspects of diagnostics. This report contains papers presented at the last in the series of Technical Committee Meetings on the Diagnostic Systems in Nuclear Power Plants organized in the framework of International Task Force

  4. Diagnostic systems in nuclear power plants. Proceedings of a technical committee meeting. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-31

    Nuclear power industry has a quite long tradition in on-line diagnostic of mechanical components and a considerable effort was put in developing diagnostic systems which are able to detect arising mechanical problems at an early stage. Computers are increasingly exploited to provide higher level information on process behaviour such as: early indication of the process deviation from normal conditions; rapid identification of the cause of any disturbance; prediction of the evolution of a disturbance; operator aid through computerized help. Following the recommendation of Several Member States to strengthen the activity in this field two divisions of IAEA established in 1995 the International Task Force on Nuclear Power Plant Diagnostics. The scope of the task force cover both technological developments and safety/licensing aspects of diagnostics. This report contains papers presented at the last in the series of Technical Committee Meetings on the Diagnostic Systems in Nuclear Power Plants organized in the framework of International Task Force Refs, figs, tabs

  5. Computerized intrapartum fetal monitoring

    International Nuclear Information System (INIS)

    Divon, M.Y.

    1986-01-01

    Preliminary clinical evaluation: Twenty healthy women were studied for 40 minutes each. All were at full-term gestation and had taken no medications during pregnancy or labor. The outcome of each of the pregnancies was entirely normal resulting in appropriately grown, non-asphyxiated infants. Results: (1) uterine contractions occupied 34% of the total observation time (mean duration = 67 +- 15 seconds (+- SD)), (2) all fetuses demonstrated FM (mean frequency = 2.5 per 10 minutes; mean duration = 11 seconds). FM were significantly more common during UC., 3) 85% of FHR accelerations were associated with FM as detected by real-time sonography, (4) FHRV rose from 5.1 +- 1.3 (mean +- SD) between UC to 6.0 +- 1.5 during UC, rho < 0.001. This system provides the clinician with clear, objective and concise information which may be useful in early recognition of the compromised fetus

  6. Computerizing clinical practice guidelines

    DEFF Research Database (Denmark)

    Lyng, Karen Marie

    It is well described that hospitals have problems with sustaining high quality of care and expedient introduction of new medical knowledge. Clinical practice guidelines (CPGs) have been promoted as a remedy to deal with these problems. It is, however, also well described that application and comp......It is well described that hospitals have problems with sustaining high quality of care and expedient introduction of new medical knowledge. Clinical practice guidelines (CPGs) have been promoted as a remedy to deal with these problems. It is, however, also well described that application...... is comprised by fieldwork in three oncology departments and a case study of advanced life support. Although close to all patients within oncology are treated according to a CPG, I found limited application of physical CPGs and web-based CPG portals. However, I found comprehensive application of activity...... of the business strategic aims, and 3) analysis and formalization of CPGs. This will imply orchestration of design teams with competencies from a wide array of disciplines such as health practice, business management, knowledge management and information systems....

  7. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  8. Duty to Inform and Informed Consent in Diagnostic Radiology: How Ethics and Law can Better Guide Practice.

    Science.gov (United States)

    Doudenkova, Victoria; Bélisle Pipon, Jean-Christophe

    2016-03-01

    Although there is consensus on the fact that ionizing radiation used in radiological examinations can affect health, the stochastic (random) nature of risk makes it difficult to anticipate and assess specific health implications for patients. The issue of radiation protection is peculiar as any dosage received in life is cumulative, the sensitivity to radiation is highly variable from one person to another, and between 20 % and 50 % of radiological examinations appear not to be necessary. In this context, one might reasonably assume that information and patient consent would play an important role in regulating radiological practice. However, there is to date no clear consensus regarding the nature and content of-or even need for-consent by patients exposed to ionizing radiation. While law and ethics support the same principles for respecting the dignity of the person (inviolability and integrity), in the context of radiology practice, they do not provide a consistent message to guide clinical decision-making. This article analyzes the issue of healthcare professionals' duty to inform and obtain patient consent for radiological examinations. Considering that both law and ethics have as one of their aims to protect vulnerable populations, it is important that they begin to give greater attention to issues raised by the use of ionizing radiation in medicine. While the situation in Canada serves as a backdrop for a reflective analysis of the problem, the conclusions are pertinent for professional practice in other jurisdictions because the principles underlying health law and jurisprudence are fairly general.

  9. Vectorcardiographic diagnostic & prognostic information derived from the 12-lead electrocardiogram: Historical review and clinical perspective.

    Science.gov (United States)

    Man, Sumche; Maan, Arie C; Schalij, Martin J; Swenne, Cees A

    2015-01-01

    In the course of time, electrocardiography has assumed several modalities with varying electrode numbers, electrode positions and lead systems. 12-lead electrocardiography and 3-lead vectorcardiography have become particularly popular. These modalities developed in parallel through the mid-twentieth century. In the same time interval, the physical concepts underlying electrocardiography were defined and worked out. In particular, the vector concept (heart vector, lead vector, volume conductor) appeared to be essential to understanding the manifestations of electrical heart activity, both in the 12-lead electrocardiogram (ECG) and in the 3-lead vectorcardiogram (VCG). Not universally appreciated in the clinic, the vectorcardiogram, and with it the vector concept, went out of use. A revival of vectorcardiography started in the 90's, when VCGs were mathematically synthesized from standard 12-lead ECGs. This facilitated combined electrocardiography and vectorcardiography without the need for a special recording system. This paper gives an overview of these historical developments, elaborates on the vector concept and seeks to define where VCG analysis/interpretation can add diagnostic/prognostic value to conventional 12-lead ECG analysis. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The PROgnostic Value of unrequested Information in Diagnostic Imaging (PROVIDI) Study: rationale and design

    International Nuclear Information System (INIS)

    Gondrie, M. J. A.; Mali, W. P. Th. M.; Buckens, C. F. M.; Jacobs, P. C. A.; Grobbee, D. E.; Graaf, Y van der

    2010-01-01

    We describe the rationale for a new study examining the prognostic value of unrequested findings in diagnostic imaging. The deployment of more advanced imaging modalities in routine care means that such findings are being detected with increasing frequency. However, as the prognostic significance of many types of unrequested findings is unknown, the optimal response to such findings remains uncertain and in many cases an overly defensive approach is adopted, to the detriment of patient-care. Additionally, novel and promising image findings that are newly available on many routine scans cannot be used to improve patient care until their prognostic value is properly determined. The PROVIDI study seeks to address these issues using an innovative multi-center case-cohort study design. PROVIDI is to consist of a series of studies investigating specific, selected disease entities and clusters. Computed Tomography images from the participating hospitals are reviewed for unrequested findings. Subsequently, this data is pooled with outcome data from a central population registry. Study populations consist of patients with endpoints relevant to the (group of) disease(s) under study along with a random control sample from the cohort. This innovative design allows PROVIDI to evaluate selected unrequested image findings for their true prognostic value in a series of manageable studies. By incorporating unrequested image findings and outcomes data relevant to patients, truly meaningful conclusions about the prognostic value of unrequested and emerging image findings can be reached and used to improve patient-care.

  11. A COMPUTERIZED OPERATOR SUPPORT SYSTEM PROTOTYPE

    Energy Technology Data Exchange (ETDEWEB)

    Thomas A. Ulrich; Roger Lew; Ronald L. Boring; Ken Thomas

    2015-03-01

    A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. A prototype COSS was developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, piping and instrumentation diagram system representations, and a recommender module for mitigation actions. The initial version of the prototype is now operational at the Idaho National Laboratory using the Human System Simulation Laboratory.

  12. Normal anatomical measurements in cervical computerized tomography

    International Nuclear Information System (INIS)

    Zaunbauer, W.; Daepp, S.; Haertel, M.

    1985-01-01

    Radiodiagnostically relevant normal values and variations for measurements of the cervical region, the arithmetical average and the standard deviation were determined from adequate computer tomograms on 60 healthy women and men, aged 20 to 83 years. The sagittal diameter of the prevertebral soft tissue and the lumina of the upper respiratory tract were evaluated at exactly defined levels between the hyoid bone and the incisura jugularis sterni. - The thickness of the aryepiglottic folds, the maximal sagittal and transverse diameters of the thyroid gland and the calibre of the great cervical vessels were defined. - To assess information about laryngeal function in computerized tomography, measurements of distances between the cervical spine and anatomical fixed points of the larynx and hypopharynx were made as well as of the degree of vocal cord movement during normal respiration and phonation. (orig.) [de

  13. Systèmes d'information en Imagerie médicale : Moyen de diagnostic ...

    African Journals Online (AJOL)

    Information Systems of the Medical Imagery: A Means of diagnosis, of therapy and of economy. The digital medical images got by the different existing modalities, and processed by powerful computers, became a very powerful means of diagnosis. They allow to follow a pathology, compare an image to another having some ...

  14. Patient radiation exposure in computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pavlov, V [Meditsinska Akademiya, Sofia (Bulgaria)

    1980-01-01

    Radiation exposure to patients undergoing axial computerized tomography as a tool of neurological X-ray diagnostics was studied. Doses thereby delivered were compared with those from routine head films at X-ray tube parameters 200 W, 70 kV, and 70 cm target-to-patient distance. Radiation exposures were analyzed with a view to improving shielding and procedural techniques. Comparisons were made using LiF TLD measurements with an Alderson phantom (standard for axial computer tomography). Skin and intracranial space doses were compared using two computers, Siretom I and Siretom 2000, for various positionings: frontal, fronto-lateral, temporal, temporo-occipital, and occipital. In addition, patient body doses with or without shielding and doses to subjects attending sick children or restless adults were examined. Achievable protection was estimated for lead shields of 0.5 mm lead equivalent. It was concluded that radiation doses delivered to neurologic patients undergoing axial computer tomography are smaller than those resulting from conventional X-ray examinations.

  15. Depression and suicidal behavior in adolescents: a multi-informant and multi-methods approach to diagnostic classification.

    Directory of Open Access Journals (Sweden)

    Andrew James Lewis

    2014-07-01

    Full Text Available Background: Informant discrepancies have been reported between parent and adolescent measures of depressive disorders and suicidality. We aimed to examine the concordance between adolescent and parent ratings of depressive disorder using both clinical interview and questionnaire measures and assess multi-informant and multi-method approaches to classification.Method: Within the context of assessment of eligibility for a randomized clinical trial, 50 parent–adolescent pairs (mean age of adolescents = 15.0 years were interviewed separately with a structured diagnostic interview for depression, the KID-SCID. Adolescent self-report and parent-report versions of the Strengths and Difficulties Questionnaire, the Short Mood and Feelings Questionnaire and the Depressive Experiences Questionnaire were also administered. We examined the diagnostic concordance rates of the parent vs. adolescent structured interview methods and the prediction of adolescent diagnosis via questionnaire methods.Results: Parent proxy reporting of adolescent depression and suicidal thoughts and behavior is not strongly concordant with adolescent report. Adolescent self-reported symptoms on depression scales provide a more accurate report of diagnosable adolescent depression than parent proxy reports of adolescent depressive symptoms. Adolescent self-report measures can be combined to improve the accuracy of classification. Parents tend to over report their adolescent’s depressive symptoms while under reporting their suicidal thoughts and behavior.Conclusion: Parent proxy report is clearly less reliable than the adolescent’s own report of their symptoms and subjective experiences, and could be considered inaccurate for research purposes. While parent report would still be sought clinically where an adolescent refuses to provide information, our findings suggest that parent reporting of adolescent suicidality should be interpreted with caution.

  16. Computerized index for teaching files

    International Nuclear Information System (INIS)

    Bramble, J.M.

    1989-01-01

    A computerized index can be used to retrieve cases from a teaching file that have radiographic findings similar to an unknown case. The probability that a user will review cases with a correct diagnosis was estimated with use of radiographic findings of arthritis in hand radiographs of 110 cases from a teaching file. The nearest-neighbor classification algorithm was used as a computer index to 110 cases of arthritis. Each case was treated as an unknown and inputted to the computer index. The accuracy of the computer index in retrieving cases with the same diagnosis (including rheumatoid arthritis, gout, psoriatic arthritis, inflammatory osteoarthritis, and pyrophosphate arthropathy) was measured. A Bayes classifier algorithm was also tested on the same database. Results are presented. The nearest-neighbor algorithm was 83%. By comparison, the estimated accuracy of the Bayes classifier algorithm was 78%. Conclusions: A computerized index to a teaching file based on the nearest-neighbor algorithm should allow the user to review cases with the correct diagnosis of an unknown case, by entering the findings of the unknown case

  17. Integration of 3d Models and Diagnostic Analyses Through a Conservation-Oriented Information System

    Science.gov (United States)

    Mandelli, A.; Achille, C.; Tommasi, C.; Fassi, F.

    2017-08-01

    In the recent years, mature technologies for producing high quality virtual 3D replicas of Cultural Heritage (CH) artefacts has grown thanks to the progress of Information Technologies (IT) tools. These methods are an efficient way to present digital models that can be used with several scopes: heritage managing, support to conservation, virtual restoration, reconstruction and colouring, art cataloguing and visual communication. The work presented is an emblematic case of study oriented to the preventive conservation through monitoring activities, using different acquisition methods and instruments. It was developed inside a project founded by Lombardy Region, Italy, called "Smart Culture", which was aimed to realise a platform that gave the users the possibility to easily access to the CH artefacts, using as an example a very famous statue. The final product is a 3D reality-based model that contains a lot of information inside it, and that can be consulted through a common web browser. In the end, it was possible to define the general strategies oriented to the maintenance and the valorisation of CH artefacts, which, in this specific case, must consider the integration of different techniques and competencies, to obtain a complete, accurate and continuative monitoring of the statue.

  18. Computerized cost model for pressurized water reactors

    International Nuclear Information System (INIS)

    Meneely, T.K.; Tabata, Hiroaki; Labourey, P.

    1999-01-01

    A computerized cost model has been developed in order to allow utility users to improve their familiarity with pressurized water reactor overnight capital costs and the various factors which influence them. This model organizes its cost data in the standard format of the Energy Economic Data Base (EEDB), and encapsulates simplified relationships between physical plant design information and capital cost information in a computer code. Model calculations are initiated from a base case, which was established using traditional cost calculation techniques. The user enters a set of plant design parameters, selected to allow consideration of plant models throughout the typical three- and four-loop PWR power range, and for plant sites in Japan, Europe, and the United States. Calculation of the new capital cost is then performed in a very brief time. The presentation of the program's output allows comparison of various cases with each other or with separately calculated baseline data. The user can start at a high level summary, and by selecting values of interest on a display grid show progressively more and more detailed information, including links to background information such as individual cost driver accounts and physical plant variables for each case. Graphical presentation of the comparison summaries is provided, and the numerical results may be exported to a spreadsheet for further processing. (author)

  19. Computerized Classification Testing with the Rasch Model

    Science.gov (United States)

    Eggen, Theo J. H. M.

    2011-01-01

    If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…

  20. Computerized operation manual (COM) of nuclear power plants

    International Nuclear Information System (INIS)

    Szegi, Z.

    1985-01-01

    This paper is to be presented at the International Seminar on Diagnoses of and Response to Abnormal Occurrences at Nuclear Power Plants organized by the International Atomic Energy Agency. The topic of presentation is the Computerized Operational Manual. This system supports the operator at disturbance situations by displaying quickly and unambiguously the operational instructions and the relevant information without mistakes. By the computerized manual the operator can determine the instruction-subsystem which reflects the real state of the power unit. From this point the system guides the operator on how to drive the unit to another determined state by providing the operational instructions at any time. A data bank is also included which contains information concerning rules restricting on maintenance and repair. The system will be realized at Paks NPP. (author)

  1. [Discussion on development of four diagnostic information scale for clinical re-evaluation of postmarketing herbs].

    Science.gov (United States)

    He, Wei; Xie, Yanming; Wang, Yongyan

    2011-12-01

    Post-marketing re-evaluation of Chinese herbs can well reflect Chinese medicine characteristics, which is the most easily overlooked the clinical re-evaluation content. Since little attention has been paid to this, study on the clinical trial design method was lost. It is difficult to improving the effectiveness and safety of traditional Chinese medicine. Therefore, more attention should be paid on re-evaluation of the clinical trial design method point about tcm syndrome such as the type of research program design, the study of Chinese medical information collection scale and statistical analysis methods, so as to improve the clinical trial design method study about tcm syndrome of Chinese herbs postmarketing re-evalutation status.

  2. Enhancing the functionality of reactor protection systems to provide diagnostic and monitoring information: The ISATTM approach

    International Nuclear Information System (INIS)

    Baldwin, J.A.; Rowe, B.J.; Jones, C.D.

    1996-01-01

    The ISAT TM architecture has been successfully implemented as the Single Channel Trip System (SCTS), part of the primary protection system of Nuclear Electric's Dungeness 'B' Advanced Gas-Cooled Reactors. The system is the first computer-based protection system licensed on a UK civil nuclear reactor. The system provides protection against single channel faults resulting in high coolant gas outlet temperature. The SCTS was designed to output data at several points in the system to an Ethernet to allow checks to be made on the operation of parts of the protection system and the system as a whole. In order to monitor the performance of this shutdown system a PC based monitoring system was developed to take input as data from the Ethernet, check its integrity and then analyze the data to provide information of the state of the system and subsystems. The SCTS monitor was basically intended to alert the operator to any fault on the safety system and indicate its source, provide a diagnosis of the cause of any trip initiated by the safety system, and log the occurrences of these incidents for later inspection. The intention was also to provide accurate real-time information on the thermocouple readings and to decrease the effort required to maintain the safety system. This paper will describe briefly the development of the ISAT TM monitoring system: how its requirements were arrived at, and how the design, code and testing were carried out to ensure approval for this application. It will then go on to report how the ISAT TM monitor has performed during its time in service: how more functionality has been added over and above its original requirements. Features of additional monitors for the SCTS and other ISAT TM systems will also be described. (author). 2 refs, 5 figs

  3. Computerizing primary schools in rural kenya

    DEFF Research Database (Denmark)

    Ogembo, J.G.; Ngugi, B.; Pelowski, Matthew John

    2012-01-01

    questions surrounding this endeavour. Specifically: 1.) what problems do rural schools actually want to solve with computerization; 2.) is computerization the most important priority for rural schools; 3.) are schools ready, in terms of infrastructure, for a computer in the classroom; or 4.) might...... and protective roofing -posing severe challenges to the outstanding conception of computerization. We consider these results and make recommendations for better adapting programs for computer introduction, and also suggest the use of new innovative devices, such as cell phones, which might already have overcome......This paper investigates the outstanding challenges facing primary schools' computerization in rural Kenya. Computerization of schools is often envisaged as a 'magic', or at least a particularly efficient, solution to many of the problems that developing countries face in improving primary school...

  4. Computerized radiation control system in the Chernobyl 30-km zone

    International Nuclear Information System (INIS)

    Vasil'chenko, D.L.; Pis'mak, A.D.; Livertovskij, G.P.; Chikhladze, V.S.

    1992-01-01

    Computerized radiation control system is intended for monitoring radiation in the zone of radiation-hazardous objects for providing nuclear power station services with current information on radiactive situation in the zone of observation and the doses of radiation taken by the personnel. Described are tasks and functions of the system, as well as its structure. It is noted that unique conditions of the Chernobyl' 30-km zone open up opportunities for experiments and testing new models of equipment. 2 figs

  5. The effects of lossy compression on diagnostically relevant seizure information in EEG signals.

    Science.gov (United States)

    Higgins, G; McGinley, B; Faul, S; McEvoy, R P; Glavin, M; Marnane, W P; Jones, E

    2013-01-01

    This paper examines the effects of compression on EEG signals, in the context of automated detection of epileptic seizures. Specifically, it examines the use of lossy compression on EEG signals in order to reduce the amount of data which has to be transmitted or stored, while having as little impact as possible on the information in the signal relevant to diagnosing epileptic seizures. Two popular compression methods, JPEG2000 and SPIHT, were used. A range of compression levels was selected for both algorithms in order to compress the signals with varying degrees of loss. This compression was applied to the database of epileptiform data provided by the University of Freiburg, Germany. The real-time EEG analysis for event detection automated seizure detection system was used in place of a trained clinician for scoring the reconstructed data. Results demonstrate that compression by a factor of up to 120:1 can be achieved, with minimal loss in seizure detection performance as measured by the area under the receiver operating characteristic curve of the seizure detection system.

  6. Physician Acceptance of a Computerized Outpatient Medication System in a Teaching Hospital Group Practice

    OpenAIRE

    Blish, Christi; Proctor, Rita; Fletcher, Suzanne W.; O'Malley, Michael

    1983-01-01

    As part of a new automated ambulatory medical record, a computerized outpatient medication system was developed for a teaching hospital general medicine group practice. Seven months after its implementation, the system was evaluated to determine physician acceptance and approval. Practice physicians were surveyed, and 94% of the respondents approved of the system. Over 90% thought that the computerized system had improved the completeness and accuracy of medication information as well as thei...

  7. A computerized system for improved management and execution of plant procedures

    International Nuclear Information System (INIS)

    Lipner, M.H.; Orendi, R.G.; Impink, A.J.; Mundy, R.A.

    1987-01-01

    The authors have shown how the deficiencies reported in this paper can be resolved by using the Computerized Procedures System. The Westinghouse Computerized Procedures System solves many of the human performance problems associated with procedures. It has been designed to assist plant operators in executing procedures more efficiently and cost effectively. The system brings all of the necessary information to one location for easy and continuous assessment of plant conditions and permits the operator to concentrate on the big picture

  8. The Extent of computerization in big companies of the Spanish hotel sector

    OpenAIRE

    Infante Moro, Alfonso; Martínez López, Francisco José; Infante Moro, Juan Carlos

    2015-01-01

    This is the first study of the hotel sector regarding the extent of computerization in its big companies. This study examines the extent of computerization in big companies of the Spanish hotel sector with the aim of confirming the viability and sustainability of this sector relative to changes in ICT, a stage which is defined by the extensive use of the Internet and online social networks, and the handling of large quantities of information generated within these new env...

  9. Computerized tomography in diagnosis of parasitic hepatic lesions

    International Nuclear Information System (INIS)

    Filimonov, G.P.; Garibashvili, R.N.; Tumol'skaya, N.I.

    1984-01-01

    An attempt has been made to estimate the diagnostic importance of computerized tomography (CT) in cases of hepatic echinococcosis and alveococcosis to outline the semiotics of these lesions and to establish an order of using CT in a general diagnostic complex. 73 patients at the age of 15-70 (49 with echinococcosis, 24-alveococcosis) have been supervised. The analysis of the results of clinical CT application in cases of parasitic hepatic lesions has shown that CT permits not only to reveal parasitic nodes up to 2 cm size in the liver and other organs but give also their topographoanatomic characteristic. By means of CT one can determine interrelations of parasitic formation with vessels and hepatic bileducts, vena cava inferior, other organs. One can judge at the same time on their compression and germination, remote echinococcosis residues, other complications

  10. The Galah Survey: Classification and Diagnostics with t-SNE Reduction of Spectral Information

    Energy Technology Data Exchange (ETDEWEB)

    Traven, G.; Zwitter, T.; Žerjal, M. [Faculty of Mathematics and Physics, University of Ljubljana, Jadranska 19, 1000 Ljubljana (Slovenia); Matijevič, G. [Leibniz-Institut für Astrophysik Potsdam (AIP), An der Sternwarte 16, D-14482 Potsdam (Germany); Kos, J.; Bland-Hawthorn, J.; De Silva, G.; Sharma, S. [Sydney Institute for Astronomy, School of Physics, A28, The University of Sydney, NSW 2006 (Australia); Asplund, M.; Freeman, K.; Lin, J.; Da Costa, G.; Duong, L. [Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 2611 (Australia); Casey, A. R. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Martell, S. L. [School of Physics, University of New South Wales, Sydney, NSW 2052 (Australia); Schlesinger, K. J. [Research School of Astronomy and Astrophysics, Mount Stromlo Observatory, Cotter Road, Weston Creek, ACT 2611 (Australia); Simpson, J. D. [Australian Astronomical Observatory, North Ryde, NSW 2113 (Australia); Zucker, D. B. [Australian Astronomical Observatory, P.O. Box 915, North Ryde, NSW 1670 (Australia); Anguiano, B. [Department of Physics and Astronomy, Macquarie University, North Ryde, NSW 2109 (Australia); Horner, J., E-mail: gregor.traven@fmf.uni-lj.si [Computational Engineering and Science Research Centre, University of Southern Queensland, Towoomba QLD 4350 (Australia); and others

    2017-02-01

    Galah is an ongoing high-resolution spectroscopic survey with the goal of disentangling the formation history of the Milky Way using the fossil remnants of disrupted star formation sites that are now dispersed around the Galaxy. It is targeting a randomly selected magnitude-limited ( V ≤ 14) sample of stars, with the goal of observing one million objects. To date, 300,000 spectra have been obtained. Not all of them are correctly processed by parameter estimation pipelines, and we need to know about them. We present a semi-automated classification scheme that identifies different types of peculiar spectral morphologies in an effort to discover and flag potentially problematic spectra and thus help to preserve the integrity of the survey results. To this end, we employ the recently developed dimensionality reduction technique t-SNE ( t -distributed stochastic neighbor embedding), which enables us to represent the complex spectral morphology in a two-dimensional projection map while still preserving the properties of the local neighborhoods of spectra. We find that the majority (178,483) of the 209,533 Galah spectra considered in this study represents normal single stars, whereas 31,050 peculiar and problematic spectra with very diverse spectral features pertaining to 28,579 stars are distributed into 10 classification categories: hot stars, cool metal-poor giants, molecular absorption bands, binary stars, H α /H β emission, H α /H β emission superimposed on absorption, H α /H β P-Cygni, H α /H β inverted P-Cygni, lithium absorption, and problematic. Classified spectra with supplementary information are presented in the catalog, indicating candidates for follow-up observations and population studies of the short-lived phases of stellar evolution.

  11. Work improvement by computerizing the process of shielding block production

    International Nuclear Information System (INIS)

    Kang, Dong Hyuk; Jeong, Do Hyeong; Kang, Dong Yoon; Jeon, Young Gung; Hwang, Jae Woong

    2013-01-01

    Introducing CR (Computed Radiography) system created a process of printing therapy irradiation images and converting the degree of enlargement. This is to increase job efficiency and contribute to work improvement using a computerized method with home grown software to simplify this process, work efficiency. Microsoft EXCEL (ver. 2007) and VISUAL BASIC (ver. 6.0) have been used to make the software. A window for each shield block was designed to enter patients' treatment information. Distances on the digital images were measured, the measured data were entered to the Excel program to calculate the degree of enlargement, and printouts were produced to manufacture shield blocks. By computerizing the existing method with this program, the degree of enlargement can easily be calculated and patients' treatment information can be entered into the printouts by using macro function. As a result, errors in calculation which may occur during the process of production or errors that the treatment information may be delivered wrongly can be reduced. In addition, with the simplification of the conversion process of the degree of enlargement, no copy machine was needed, which resulted in the reduction of use of paper. Works have been improved by computerizing the process of block production and applying it to practice which would simplify the existing method. This software can apply to and improve the actual conditions of each hospital in various ways using various features of EXCEL and VISUAL BASIC which has already been proven and used widely

  12. Work improvement by computerizing the process of shielding block production

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dong Hyuk; Jeong, Do Hyeong; Kang, Dong Yoon; Jeon, Young Gung; Hwang, Jae Woong [Proton Therapy Center, National Cancer Center, Goyang (Korea, Republic of)

    2013-09-15

    Introducing CR (Computed Radiography) system created a process of printing therapy irradiation images and converting the degree of enlargement. This is to increase job efficiency and contribute to work improvement using a computerized method with home grown software to simplify this process, work efficiency. Microsoft EXCEL (ver. 2007) and VISUAL BASIC (ver. 6.0) have been used to make the software. A window for each shield block was designed to enter patients' treatment information. Distances on the digital images were measured, the measured data were entered to the Excel program to calculate the degree of enlargement, and printouts were produced to manufacture shield blocks. By computerizing the existing method with this program, the degree of enlargement can easily be calculated and patients' treatment information can be entered into the printouts by using macro function. As a result, errors in calculation which may occur during the process of production or errors that the treatment information may be delivered wrongly can be reduced. In addition, with the simplification of the conversion process of the degree of enlargement, no copy machine was needed, which resulted in the reduction of use of paper. Works have been improved by computerizing the process of block production and applying it to practice which would simplify the existing method. This software can apply to and improve the actual conditions of each hospital in various ways using various features of EXCEL and VISUAL BASIC which has already been proven and used widely.

  13. Sustained User Engagement in Health Information Technology: The Long Road from Implementation to System Optimization of Computerized Physician Order Entry and Clinical Decision Support Systems for Prescribing in Hospitals in England.

    Science.gov (United States)

    Cresswell, Kathrin M; Lee, Lisa; Mozaffar, Hajar; Williams, Robin; Sheikh, Aziz

    2017-10-01

    To explore and understand approaches to user engagement through investigating the range of ways in which health care workers and organizations accommodated the introduction of computerized physician order entry (CPOE) and computerized decision support (CDS) for hospital prescribing. Six hospitals in England, United Kingdom. Qualitative case study. We undertook qualitative semi-structured interviews, non-participant observations of meetings and system use, and collected organizational documents over three time periods from six hospitals. Thematic analysis was initially undertaken within individual cases, followed by cross-case comparisons. We conducted 173 interviews, conducted 24 observations, and collected 17 documents between 2011 and 2015. We found that perceived individual and safety benefits among different user groups tended to facilitate engagement in some, while other less engaged groups developed resistance and unsanctioned workarounds if systems were perceived to be inadequate. We identified both the opportunity and need for sustained engagement across user groups around system enhancement (e.g., through customizing software) and the development of user competencies and effective use. There is an urgent need to move away from an episodic view of engagement focused on the preimplementation phase, to more continuous holistic attempts to engage with and respond to end-users. © Health Research and Educational Trust.

  14. Psychometrics behind Computerized Adaptive Testing.

    Science.gov (United States)

    Chang, Hua-Hua

    2015-03-01

    The paper provides a survey of 18 years' progress that my colleagues, students (both former and current) and I made in a prominent research area in Psychometrics-Computerized Adaptive Testing (CAT). We start with a historical review of the establishment of a large sample foundation for CAT. It is worth noting that the asymptotic results were derived under the framework of Martingale Theory, a very theoretical perspective of Probability Theory, which may seem unrelated to educational and psychological testing. In addition, we address a number of issues that emerged from large scale implementation and show that how theoretical works can be helpful to solve the problems. Finally, we propose that CAT technology can be very useful to support individualized instruction on a mass scale. We show that even paper and pencil based tests can be made adaptive to support classroom teaching.

  15. Chinese computerized nuclear data library

    International Nuclear Information System (INIS)

    Liang Qichang; Cai Dunjiu

    1996-01-01

    The Second Version of Chinese Evaluated Nuclear Data Library (CENDL-2) includes the complete neutron nuclear data sets of 54 important elements and isotopes used for nuclear science and engineering with the incident neutron energy from 10 -5 eV to 20 MeV, the international universal format ENDF/B-6 was adopted. Now, the Chinese Computerized nuclear data library has been developed and put into operation. That is, the users can make on-line use of the main data libraries for evaluated neutron reaction data in the world of EXFOR experimental nuclear data library on the terminal of computer via the perfect computer software system, carry out directly the nuclear engineering calculation or nuclear data evaluation, enjoy the use of the resource of our nuclear data libraries for their development of nuclear energy and nuclear technology applications

  16. Computerized evaluation of flood impact

    International Nuclear Information System (INIS)

    Gagnon, J.; Quach, T.T.; Marche, C.; Lessard, G.

    1998-01-01

    A computerized evaluation process for assessing the economic impacts of a potential dam failure is described. The DOMINO software, which was developed by Hydro-Quebec, takes into account flow data from dam break simulations of floods, the territory involved, plus the economic evaluations of the real estate and infrastructures affected. Some examples of software applications and impact evaluations are presented. The principal elements involved in estimating economic or other types of impacts induced by natural flooding or dam failure, are: (1) flow forecasting, (2) defining the contour of the involved territory, and (3) accounting for the various impacts identified in the affected zone. Owing to its wide range of functions and utilities, DOMINO has proven to be a very useful, user-friendly and portable decision-making tool. 5 refs., 6 tabs

  17. Computers in radiology. The sedation, analgesia, and contrast media computerized simulator: a new approach to train and evaluate radiologists' responses to critical incidents

    International Nuclear Information System (INIS)

    Medina, L.S.; Racadio, J.M.; Schwid, H.A.

    2000-01-01

    Background. Awareness and preparedness to handle sedation, analgesia, and contrast-media complications are key in the daily radiology practice. Objective. The purpose is to create a computerized simulator (PC-Windows-based) that uses a graphical interface to reproduce critical incidents in pediatric and adult patients undergoing a wide spectrum of radiologic sedation, analgesia and contrast media complications. Materials and methods. The computerized simulator has a comprehensive set of physiologic and pharmacologic models that predict patient response to management of sedation, analgesia, and contrast-media complications. Photorealistic images, real-time monitors, and mouse-driven information demonstrate in a virtual-reality fashion the behavior of the patient in crisis. Results. Thirteen pediatric and adult radiology scenarios are illustrated encompassing areas such as pediatric radiology, neuroradiology, interventional radiology, and body imaging. The multiple case scenarios evaluate randomly the diagnostic and management performance of the radiologist in critical incidents such as oversedation, anaphylaxis, aspiration, airway obstruction, apnea, agitation, bronchospasm, hypotension, hypertension, cardiac arrest, bradycardia, tachycardia, and myocardial ischemia. The user must control the airway, breathing and circulation, and administer medications in a timely manner to save the simulated patient. On-line help is available in the program to suggest diagnostic and treatment steps to save the patient, and provide information about the medications. A printout of the case management can be obtained for evaluation or educational purposes. Conclusion. The interactive computerized simulator is a new approach to train and evaluate radiologists' responses to critical incidents encountered during radiologic sedation, analgesia, and contrast-media administration. (orig.)

  18. Diagnostic information system dynamics in the evaluation of machine learning algorithms for the supervision of energy efficiency of district heating-supplied buildings

    International Nuclear Information System (INIS)

    Kiluk, Sebastian

    2017-01-01

    Highlights: • Energy efficiency classification sustainability benefits from knowledge prediction. • Diagnostic classification can be validated with its dynamics and current data. • Diagnostic classification dynamics provides novelty extraction for knowledge update. • Data mining comparison can be performed with knowledge dynamics and uncertainty. • Diagnostic information refinement benefits form comparing classifiers dynamics. - Abstract: Modern ways of exploring the diagnostic knowledge provided by data mining and machine learning raise some concern about the ways of evaluating the quality of output knowledge, usually represented by information systems. Especially in district heating, the stationarity of efficiency models, and thus the relevance of diagnostic classification system, cannot be ensured due to the impact of social, economic or technological changes, which are hard to identify or predict. Therefore, data mining and machine learning have become an attractive strategy for automatically and continuously absorbing such dynamics. This paper presents a new method of evaluation and comparison of diagnostic information systems gathered algorithmically in district heating efficiency supervision based on exploring the evolution of information system and analyzing its dynamic features. The process of data mining and knowledge discovery was applied to the data acquired from district heating substations’ energy meters to provide the automated discovery of diagnostic knowledge base necessary for the efficiency supervision of district heating-supplied buildings. The implemented algorithm consists of several steps of processing the billing data, including preparation, segmentation, aggregation and knowledge discovery stage, where classes of abstract models representing energy efficiency constitute an information system representing diagnostic knowledge about the energy efficiency of buildings favorably operating under similar climate conditions and

  19. Presentation of Diagnostic Information to Doctors May Change Their Interpretation and Clinical Management: A Web-Based Randomised Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Yoav Ben-Shlomo

    Full Text Available There is little evidence on how best to present diagnostic information to doctors and whether this makes any difference to clinical management. We undertook a randomised controlled trial to see if different data presentations altered clinicians' decision to further investigate or treat a patient with a fictitious disorder ("Green syndrome" and their ability to determine post-test probability.We recruited doctors registered with the United Kingdom's largest online network for medical doctors between 10 July and 6" November 2012. Participants were randomised to one of four arms: (a text summary of sensitivity and specificity, (b Fagan's nomogram, (c probability-modifying plot (PMP, (d natural frequency tree (NFT. The main outcome measure was the decision whether to treat, not treat or undertake a brain biopsy on the hypothetical patient and the correct post-test probability. Secondary outcome measures included knowledge of diagnostic tests.917 participants attempted the survey and complete data were available from 874 (95.3%. Doctors randomized to the PMP and NFT arms were more likely to treat the patient than those randomized to the text-only arm. (ORs 1.49, 95% CI 1.02, 2.16 and 1.43, 95% CI 0.98, 2.08 respectively. More patients randomized to the PMP (87/218-39.9% and NFT (73/207-35.3% arms than the nomogram (50/194-25.8% or text only (30/255-11.8% arms reported the correct post-test probability (p <0.001. Younger age, postgraduate training and higher self-rated confidence all predicted better knowledge performance. Doctors with better knowledge were more likely to view an optional learning tutorial (OR per correct answer 1.18, 95% CI 1.06, 1.31.Presenting diagnostic data using a probability-modifying plot or natural frequency tree influences the threshold for treatment and improves interpretation of tests results compared to text summary of sensitivity and specificity or Fagan's nomogram.

  20. Presentation of Diagnostic Information to Doctors May Change Their Interpretation and Clinical Management: A Web-Based Randomised Controlled Trial.

    Science.gov (United States)

    Ben-Shlomo, Yoav; Collin, Simon M; Quekett, James; Sterne, Jonathan A C; Whiting, Penny

    2015-01-01

    There is little evidence on how best to present diagnostic information to doctors and whether this makes any difference to clinical management. We undertook a randomised controlled trial to see if different data presentations altered clinicians' decision to further investigate or treat a patient with a fictitious disorder ("Green syndrome") and their ability to determine post-test probability. We recruited doctors registered with the United Kingdom's largest online network for medical doctors between 10 July and 6" November 2012. Participants were randomised to one of four arms: (a) text summary of sensitivity and specificity, (b) Fagan's nomogram, (c) probability-modifying plot (PMP), (d) natural frequency tree (NFT). The main outcome measure was the decision whether to treat, not treat or undertake a brain biopsy on the hypothetical patient and the correct post-test probability. Secondary outcome measures included knowledge of diagnostic tests. 917 participants attempted the survey and complete data were available from 874 (95.3%). Doctors randomized to the PMP and NFT arms were more likely to treat the patient than those randomized to the text-only arm. (ORs 1.49, 95% CI 1.02, 2.16) and 1.43, 95% CI 0.98, 2.08 respectively). More patients randomized to the PMP (87/218-39.9%) and NFT (73/207-35.3%) arms than the nomogram (50/194-25.8%) or text only (30/255-11.8%) arms reported the correct post-test probability (p text summary of sensitivity and specificity or Fagan's nomogram.

  1. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians.

    Science.gov (United States)

    Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir

    2013-01-01

    We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Sonography and computerized tomography in a comparison in renal mass diseases

    International Nuclear Information System (INIS)

    Brommer, M.

    1981-01-01

    One hundred and thirteen patients with renal mass processes were examined sonographically and by computized tomography. The diagnosis was assured in 32 cases histologically, in 40 cases angiographically clinically and by the course and in 41 cases only clinically and by the course resp. by sonographic and computerized tomography control studies. The accuracy of a hit in sonography is smaller compared with computerized tomography with fast image formation. However, due to its relative safety, it is judged as the most useful technique for a first diagnossis of renal masses after ureographic diagnostic of excreta. A diagnostic procedure is proposed in which the number of necessary angiographies and diagnostic sampling surgery can be considerably reduced. (orig.) [de

  3. Contrast-enhanced multidetector computerized tomography for odontogenic cysts and cystic-appearing tumors of the jaws: is it useful?

    Science.gov (United States)

    Kakimoto, Naoya; Chindasombatjaroen, Jira; Tomita, Seiki; Shimamoto, Hiroaki; Uchiyama, Yuka; Hasegawa, Yoko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei

    2013-01-01

    The purpose of this study was to investigate the usefulness of computerized tomography (CT), particularly contrast-enhanced CT, in differentiation of jaw cysts and cystic-appearing tumors. We retrospectively analyzed contrast-enhanced CT images of 90 patients with odontogenic jaw cysts or cystic-appearing tumors. The lesion size and CT values were measured and the short axis to long axis (S/L) ratio, contrast enhancement (CE) ratio, and standard deviation ratio were calculated. The lesion size and the S/L ratio of keratocystic odontogenic tumors were significantly different from those of radicular cysts and follicular cysts. There were no significant differences in the CE ratio among the lesions. Multidetector CT provided diagnostic information about the size of odontogenic cysts and cystic-appearing tumors of the jaws that was related to the lesion type, but showed no relation between CE ratio and the type of these lesions. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Reflecting on the ethical administration of computerized medical records

    Science.gov (United States)

    Collmann, Jeff R.

    1995-05-01

    This presentation examines the ethical issues raised by computerized image management and communication systems (IMAC), the ethical principals that should guide development of policies, procedures and practices for IMACS systems, and who should be involved in developing a hospital's approach to these issues. The ready access of computerized records creates special hazards of which hospitals must beware. Hospitals must maintain confidentiality of patient's records while making records available to authorized users as efficiently as possible. The general conditions of contemporary health care undermine protecting the confidentiality of patient record. Patients may not provide health care institutions with information about themselves under conditions of informed consent. The field of information science must design sophisticated systems of computer security that stratify access, create audit trails on data changes and system use, safeguard patient data from corruption, and protect the databases from outside invasion. Radiology professionals must both work with information science experts in their own hospitals to create institutional safeguards and include the adequacy of security measures as a criterion for evaluating PACS systems. New policies and procedures on maintaining computerized patient records must be developed that obligate all members of the health care staff, not just care givers. Patients must be informed about the existence of computerized medical records, the rules and practices that govern their dissemination and given the opportunity to give or withhold consent for their use. Departmental and hospital policies on confidentiality should be reviewed to determine if revisions are necessary to manage computer-based records. Well developed discussions of the ethical principles and administrative policies on confidentiality and informed consent and of the risks posed by computer-based patient records systems should be included in initial and continuing

  5. Cost-effectiveness analysis of malaria rapid diagnostic test incentive schemes for informal private healthcare providers in Myanmar.

    Science.gov (United States)

    Chen, Ingrid T; Aung, Tin; Thant, Hnin Nwe Nwe; Sudhinaraset, May; Kahn, James G

    2015-02-05

    The emergence of artemisinin-resistant Plasmodium falciparum parasites in Southeast Asia threatens global malaria control efforts. One strategy to counter this problem is a subsidy of malaria rapid diagnostic tests (RDTs) and artemisinin-based combination therapy (ACT) within the informal private sector, where the majority of malaria care in Myanmar is provided. A study in Myanmar evaluated the effectiveness of financial incentives vs information, education and counselling (IEC) in driving the proper use of subsidized malaria RDTs among informal private providers. This cost-effectiveness analysis compares intervention options. A decision tree was constructed in a spreadsheet to estimate the incremental cost-effectiveness ratios (ICERs) among four strategies: no intervention, simple subsidy, subsidy with financial incentives, and subsidy with IEC. Model inputs included programmatic costs (in dollars), malaria epidemiology and observed study outcomes. Data sources included expenditure records, study data and scientific literature. Model outcomes included the proportion of properly and improperly treated individuals with and without P. falciparum malaria, and associated disability-adjusted life years (DALYs). Results are reported as ICERs in US dollars per DALY averted. One-way sensitivity analysis assessed how outcomes depend on uncertainty in inputs. ICERs from the least to most expensive intervention are: $1,169/DALY averted for simple subsidy vs no intervention, $185/DALY averted for subsidy with financial incentives vs simple subsidy, and $200/DALY averted for a subsidy with IEC vs subsidy with financial incentives. Due to decreasing ICERs, each strategy was also compared to no intervention. The subsidy with IEC was the most favourable, costing $639/DALY averted compared with no intervention. One-way sensitivity analysis shows that ICERs are most affected by programme costs, RDT uptake, treatment-seeking behaviour, and the prevalence and virulence of non

  6. [Computerized medical record: deontology and legislation].

    Science.gov (United States)

    Allaert, F A; Dusserre, L

    1996-02-01

    Computerization of medical records is making headway for patients' follow-up, scientific research, and health expenses control, but it must not alter the guarantees provided to the patients by the medical code of ethics and the law of January 6, 1978. This law, modified on July 1, 1994, requires to register all computerized records of personal data and establishes rights to protect privacy against computer misdemeanor. All medical practitioners using computerized medical records must be aware that the infringement of this law may provoke suing in professional, civil or criminal court.

  7. Microcomputer Network for Computerized Adaptive Testing (CAT)

    Science.gov (United States)

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  8. Molecular classification of endometrial carcinoma on diagnostic specimens is highly concordant with final hysterectomy: Earlier prognostic information to guide treatment.

    Science.gov (United States)

    Talhouk, Aline; Hoang, Lien N; McConechy, Melissa K; Nakonechny, Quentin; Leo, Joyce; Cheng, Angela; Leung, Samuel; Yang, Winnie; Lum, Amy; Köbel, Martin; Lee, Cheng-Han; Soslow, Robert A; Huntsman, David G; Gilks, C Blake; McAlpine, Jessica N

    2016-10-01

    Categorization and risk stratification of endometrial carcinomas is inadequate; histomorphologic assessment shows considerable interobserver variability, and risk of metastases and recurrence can only be derived after surgical staging. We have developed a Proactive Molecular Risk classification tool for Endometrial cancers (ProMisE) that identifies four distinct prognostic subgroups. Our objective was to assess whether molecular classification could be performed on diagnostic endometrial specimens obtained prior to surgical staging and its concordance with molecular classification performed on the subsequent hysterectomy specimen. Sequencing of tumors for exonuclease domain mutations (EDMs) in POLE and immunohistochemistry for mismatch repair (MMR) proteins and p53 were applied to both pre- and post-staging archival specimens from 60 individuals to identify four molecular subgroups: MMR-D, POLE EDM, p53 wild type, p53 abn (abnormal). Three gynecologic subspecialty pathologists assigned histotype and grade to a subset of samples. Concordance of molecular and clinicopathologic subgroup assignments were determined, comparing biopsy/curetting to hysterectomy specimens. Complete molecular and pathologic categorization was achieved in 57 cases. Concordance metrics for pre- vs. post-staging endometrial samples categorized by ProMisE were highly favorable; average per ProMisE class sensitivity(0.9), specificity(0.96), PPV(0.9), NPV(0.96) and kappa statistic 0.86(95%CI, 0.72-0.93), indicating excellent agreement. We observed the highest level of concordance for 'p53 abn' tumors, the group associated with the worst prognosis. In contrast, grade and histotype assignment from original pathology reports pre- vs. post-staging showed only moderate levels of agreement (kappa=0.55 and 0.44 respectively); even with subspecialty pathology review only moderate levels of agreement were observed. Molecular classification can be achieved on diagnostic endometrial samples and accurately

  9. Validation of the computerized annunciation message list system (CAMLS)

    Energy Technology Data Exchange (ETDEWEB)

    Feher, M P; Davey, E C; Lupton, L R [AECL, Chalk River Labs., Chalk River, ON (Canada)

    1997-09-01

    The Computerized Annunciation Message List System is a computerized annunciation system for the control rooms of nuclear generating stations. CAMLS will alert operators to changes in plant conditions that may impact on safety and production and help staff to effectively respond. CAMLS is designed to: provide a clear and concise overview of the current problems or faults in the plant; provide an overview of the current state of the plant in terms of automatic process and equipment actions; provide support for specific operational tasks, through either pre-configured or operator-configured annunciation displays, including: rapid and efficient upset response, plant stabilization, problem diagnosis, recovery action planning and implementation, and rapid recovery from trip and return to power operation. To achieve this, several information processing, presentation,a nd interaction concepts were developed. 2 refs, 6 figs, 7 tabs.

  10. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  11. Transformations and algorithms in a computerized brain atlas

    International Nuclear Information System (INIS)

    Thurfjell, L.; Bohm, C.; Eriksson, L.; Karolinska Institute/Hospital, Stockholm

    1993-01-01

    The computerized brain atlas constructed at the Karolinska Hospital, Stockholm, Sweden, has been further developed. This atlas was designed to be employed in different fields of neuro imaging such as positron emission tomography (PET), single photon emission tomography (SPECT), computerized tomography (CT) and magnetic resonance imaging (MR). The main objectives with the atlas is to aid the interpretation of functional images by introducing anatomical information, to serve as a tool in the merging of data from different imaging modalities and to facilitate the comparisons of data from different individuals by allowing for anatomical standardization of individual data. The purpose of this paper is to describe the algorithms and transformations used in the implementation of the atlas software

  12. Validation of the computerized annunciation message list system (CAMLS)

    International Nuclear Information System (INIS)

    Feher, M.P.; Davey, E.C.; Lupton, L.R.

    1997-01-01

    The Computerized Annunciation Message List System is a computerized annunciation system for the control rooms of nuclear generating stations. CAMLS will alert operators to changes in plant conditions that may impact on safety and production and help staff to effectively respond. CAMLS is designed to: provide a clear and concise overview of the current problems or faults in the plant; provide an overview of the current state of the plant in terms of automatic process and equipment actions; provide support for specific operational tasks, through either pre-configured or operator-configured annunciation displays, including: rapid and efficient upset response, plant stabilization, problem diagnosis, recovery action planning and implementation, and rapid recovery from trip and return to power operation. To achieve this, several information processing, presentation,a nd interaction concepts were developed. 2 refs, 6 figs, 7 tabs

  13. Strategy generator in computerized accident management support system

    International Nuclear Information System (INIS)

    Sirola, M.

    1994-02-01

    An increased interest for research in the field of accident management of nuclear power plants can be noted. Several international programmes have been started in order to be able to understand the basic physical and chemical phenomena in accident conditions. A feasibility study has shown that it would be possible to design and develop a computerized support system for plant staff in accident situations. To achieve this goal the Halden Project has initiated a research programme on Computerized Accident Management Support (CAMS project). The aim is to utilize the capabilities of computerized tools to support the plant staff during the various accident stages. The system will include identification of the accident state, assessment of the future development of the accident and planning of accident mitigation strategies. A prototype is developed to support operators and the Technical Support Centre in decision making during serious accidents in nuclear power plants. A rule based system has been built to take care of the strategy generation. This system assists plant personnel in planning control proposals and mitigation strategies from normal operation to severe accident conditions. The idea of a safety objective tree and knowledge from the emergency procedures have been used. Future prediction requires good state identification of the plant status and some knowledge about the history of some critical variables. The information needs to be validated as well. Accurate calculations in simulators and a large database including all important information from the plant will help the strategy planning. (orig.). (40 refs., 20 figs.)

  14. Experimental studies of computerized procedures and team size in nuclear power plant operations

    International Nuclear Information System (INIS)

    Huang, F.-H.; Hwang, S.-L.

    2009-01-01

    The operation of a nuclear power plant is so complex that it requires teamwork. To support team performance, a system need to provide all team members integrated information displays as well as decision aids (e.g., computerized procedures). Two experiments were conducted to investigate the effects of computerized procedures and team size on operating performance. Forty-five participants were involved in the experiments. Each participant executed decision and action tasks to deal with alarm signals, while detecting occasional system errors in the interface. Results showed that effects of computerized procedures were significant on various performance indicators, such as operation time, operation errors, and learning effect, and that two operators would be a satisfactory size in the teamwork system providing computerized procedures

  15. Towards a research informed teaching experience within a diagnostic radiography curriculum: The level 4 (year 1) student holistic experience

    International Nuclear Information System (INIS)

    Higgins, Robert; Hogg, Peter; Robinson, Leslie

    2013-01-01

    Aim: This article discusses the level 4 (year 1) diagnostic radiography student holistic experience of the Research-informed Teaching experience (RiTe) at the University of Salford, UK. The purpose of RiTe is to expose undergraduate radiography students to more formal research, as part of their normal teaching and learning experience. Method: A grounded theory approach was adopted and a focus group with eight level 4 students was used to explore and evaluate the student experience and perception of RiTe. Results: Open coding defined categories and sub-categories, with axial and selective coding used to interrogate and explore the relationships between the focus group data. A number of insights were gained into the student holistic experience of RiTe. The issue of leadership for level 4 students was also identified. Discussion: The focus group participants found RiTe to be an extremely positive learning experience. RiTe also facilitated their translation of learnt theory into clinical skills knowledge alongside their understanding of and desire to participate in more research as undergraduates. The article also highlights areas for future research.

  16. Human Reliability Analysis For Computerized Procedures

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Gertman, David I.; Le Blanc, Katya

    2011-01-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  17. Computerized Interpretation of Dynamic Breast MRI

    National Research Council Canada - National Science Library

    Chen, Weijie; Giger, Maryellen Lissak

    2005-01-01

    ... and prognosis of breast cancer. The research involves investigation of automatic methods for image artifacts correction, tumor segmentation, and extraction of computerized features that help distinguish between benign and malignant lesions...

  18. Effective doses and standardised risk factors from paediatric diagnostic medical radiation exposures: Information for radiation risk communication

    International Nuclear Information System (INIS)

    Bibbo, Giovanni

    2018-01-01

    In the paediatric medical radiation setting, there is no consistency on the radiation risk information conveyed to the consumer (patient/carer). Each communicator may convey different information about the level of risk for the same radiation procedure, leaving the consumer confused and frustrated. There is a need to standardise risks resulting from medical radiation exposures. In this study, paediatric radiographic, fluoroscopic, CT and nuclear medicine examination data have been analysed to provide (i) effective doses and radiation induced cancer risk factors from common radiological and nuclear medicine diagnostic procedures in standardised formats, (II) awareness of the difficulties that may be encountered in communicating risks to the layperson, and (iii) an overview of the deleterious effects of ionising radiation so that the risk communicator can convey with confidence the risks resulting from medical radiation exposures. Paediatric patient dose data from general radiographic, computed tomography, fluoroscopic and nuclear medicine databases have been analysed in age groups 0 to <5 years, 5 to <10 years, 10 to <15 years and 15 to <18 years to determine standardised risk factors. Mean, minimum and maximum effective doses and the corresponding mean lifetime risks for general radiographic, fluoroscopic, CT and nuclear medicine examinations for different age groups have been calculated. For all examinations, the mean lifetime cancer induction risk is provided in three formats: statistical, fraction and category. Standardised risk factors for different radiological and nuclear medicine examinations and an overview of the deleterious effects of ionising radiation and the difficulties encountered in communicating the risks should facilitate risk communication to the patient/carer.

  19. Study on computerized presentation of emergency procedures of a nuclear plant (step 2). The guidelines of the prototype of the computerized procedure presentation system

    International Nuclear Information System (INIS)

    Niwa, Yuji; Hollnagel, E.; Iwaki, Toshio.

    1995-01-01

    New methods of information presentation and interface design are changing the working conditions in the modern Nuclear Power Plant (NPP) control room. One area receiving considerable attention is that of Emergency Operating Procedures (EOPs), which plays an essential role in NPPs. Conventionally procedures are presented in a hard copy form. However developments in information technology have offered new opportunities for the computerization of such procedures. Consideration for the first stage of computerization should be focused upon the presentation of procedures. The specification of the computerized presentation of procedures is discussed with respect to the issues which were central to the project: navigation through procedures; formatting and presentation of procedures; and process monitoring. Issues that would be included in more advanced systems, such as help and explanation facilities features, and process linking, are also discussed. This paper deals with the specific design guidelines that were implemented for the computerization of procedure presentation. Issues of principal concern that were identified from this experience are highlighted, such as the relationship between procedure presentation and format; the registration of progress through a procedure; compensation for the limitations of computer displays versus printed documents; and the way in which the added capabilities of computerized presentation can be generally utilized in the operators' working environment. (author)

  20. Computerized provider order entry systems.

    Science.gov (United States)

    2001-01-01

    Computerized provider order entry (CPOE) systems are designed to replace a hospital's paper-based ordering system. They allow users to electronically write the full range of orders, maintain an online medication administration record, and review changes made to an order by successive personnel. They also offer safety alerts that are triggered when an unsafe order (such as for a duplicate drug therapy) is entered, as well as clinical decision support to guide caregivers to less expensive alternatives or to choices that better fit established hospital protocols. CPOE systems can, when correctly configured, markedly increase efficiency and improve patient safety and patient care. However, facilities need to recognize that currently available CPOE systems require a tremendous amount of time and effort to be spent in customization before their safety and clinical support features can be effectively implemented. What's more, even after they've been customized, the systems may still allow certain unsafe orders to be entered. Thus, CPOE systems are not currently a quick or easy remedy for medical errors. ECRI's Evaluation of CPOE systems--conducted in collaboration with the Institute for Safe Medication Practices (ISMP)--discusses these and other related issues. It also examines and compares CPOE systems from three suppliers: Eclipsys Corp., IDX Systems Corp., and Siemens Medical Solutions Health Services Corp. Our testing focuses primarily on the systems' interfacing capabilities, patient safeguards, and ease of use.

  1. Physical and Cognitive Functioning After 3 Years Can Be Predicted Using Information From the Diagnostic Process in Recently Diagnosed Multiple Sclerosis

    NARCIS (Netherlands)

    de Groot, V.; Beckerman, H.; Uitdehaag, B.M.J.; Hintzen, R.Q.; Minneboo, A.; Heymans, M.W.; Lankhorst, G.J.; Polman, C.H.; Bouter, L.M.

    2009-01-01

    de Groot V, Beckerman H, Uitdehaag BM, Hintzen RQ, Minneboo A, Heymans MW, Lankhorst GJ, Polman CH, Bouter LM, on behalf of the Functional Prognostication and Disability (FuPro) Study Group. Physical and cognitive functioning after 3 years can be predicted using information from the diagnostic

  2. Appropriate use of diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, P.E.S.; Cockshott, W.P.

    1984-11-16

    This article discusses ways in which more appropriate use can be made of roentgenography with a resulting decrease in radiation doses to the patient population. The authors recommend that fewer films be made and that traditional roentgenography be replaced with endoscopy, ultrasound, computerized tomography, or angiography where appropriate. They also recommend that medical schools and medical subspecialty groups study the World Health Organization document which provides indications for diagnostic imaging, the choice of procedure and the limitations of each.

  3. Language networks associated with computerized semantic indices.

    Science.gov (United States)

    Pakhomov, Serguei V S; Jones, David T; Knopman, David S

    2015-01-01

    Tests of generative semantic verbal fluency are widely used to study organization and representation of concepts in the human brain. Previous studies demonstrated that clustering and switching behavior during verbal fluency tasks is supported by multiple brain mechanisms associated with semantic memory and executive control. Previous work relied on manual assessments of semantic relatedness between words and grouping of words into semantic clusters. We investigated a computational linguistic approach to measuring the strength of semantic relatedness between words based on latent semantic analysis of word co-occurrences in a subset of a large online encyclopedia. We computed semantic clustering indices and compared them to brain network connectivity measures obtained with task-free fMRI in a sample consisting of healthy participants and those differentially affected by cognitive impairment. We found that semantic clustering indices were associated with brain network connectivity in distinct areas including fronto-temporal, fronto-parietal and fusiform gyrus regions. This study shows that computerized semantic indices complement traditional assessments of verbal fluency to provide a more complete account of the relationship between brain and verbal behavior involved organization and retrieval of lexical information from memory. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Nuclear Computerized Library for Assessing Reactor Risk (NUCLARR)

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Blackman, H.S.; Ryan, T.G.

    1986-01-01

    The Nuclear Computerized Library for Assessing Reactor Risk (NUCLARR) program is a multiyear effort sponsored by the NRC and is being conducted at the Idaho National Engineering Laboratory (INEL). The goal of this program is to establish and operate computerized data base management tools for the human reliability data bank specification developed by Comer and Donovan. The NRC and the risk analysis community recognized that implementing a fully functional library would not be feasible, or practical, without the aid of computerized tools for management and manipulation of its data sources. The end users of the NUCLARR can be classified into three categories according to specific needs. The first category is those users interested in reviewing individual data sources for a given situation. The second category of users selects multiple data sources for a specific case, summarizing the information, and performing comparative studies. The last category of users interfaces the NUCLARR with other programming applications, such as other data banks, and simulation models of risk assessment. Project status is provided in the paper

  5. How does a change in the control room design affect diagnostic strategies in nuclear power plants?

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Jonghyun

    2014-01-01

    Recently, main control rooms have been considerably changed by modern computer techniques. Some of the features that distinguish digital control rooms from conventional, analog rooms in nuclear power plants include advanced alarm systems, graphic information display systems, computerized procedure systems, and soft control. These features can bring changes in operator tasks, changing the characteristics of tasks or creating new tasks for operators. It is especially expected that these features may bring out changes in the operator's diagnostic tasks and strategies in a digital control room as compared with an analog control room. This study investigates the differences in the operator's diagnostic tasks and strategies in analog and digital control rooms. This study also attempts to evaluate how new systems in a digital control room affect diagnostic strategies. Three different approaches, which are complementary, are used to identify diagnostic strategies in the digital control room and in the analog control room: (1) observation in the simulator, (2) interview with operators, and (3) a literature review. The results show that the digital control room introduces new diagnosis strategies compared with the analog control room while also changing the characteristics of the strategies, mostly by gaining more support from the computerized system. (author)

  6. The Development of CPSES Plug-in(CPMP) for APR1400 Computerized Procedure Effective Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Seong, No Kyu; Park, Jin Kyun; Jung, Yeon Sub [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The Computerized Procedure System (CPS) is one of the Man Machine Interface (MMI) resources of the Shin-Kori 3 and 4 nuclear power plants. The CPS is a computerized operator support system that enables operating crew to execute procedures in an accurate and fast manner. The Computerized Procedure (CP) is the XML data file in executable format that can be installed in the Procedure eXecution System (PXS) for execution. The CP contains specific information related to a particular procedure (i.e. LOCA). These computerized procedures such as Alarm Response Procedures (ARP) are separated into individual alarm procedure to maximize function interface between CPS and DCS. E.g. 'Procedure open by alarm list'. The procedure writer's burden to manage many procedures has been increased because of separated procedures. This paper introduces Computerized Procedure System Engineering System (CPSES) plug-in that is computerized procedure management program (CPMP) to reduce procedure writer's burden. This paper introduces the main features of CPMP. CPMP reduces procedure writer's or CPX maintainer's burden. This program is implemented and tested by program design requirement.

  7. An ergonomics study of computerized emergency operating procedures: Presentation style, task complexity, and training level

    International Nuclear Information System (INIS)

    Xu Song; Song Fei; Li Zhizhong; Zhao Qianyi; Luo Wei; He Xuhong; Salvendy, Gavriel

    2008-01-01

    Emergency operating procedures (EOPs) are widely used in nuclear power plants (NPPs). With the development of information technology, computerized EOPs are taking the place of paper-based ones. Unlike paper-based EOPs, the industrial practice of computerized EOPs is still quite limited. Ergonomics issues of computerized EOPs have not been studied adequately. This study focuses on the effects of EOP presentation style, task complexity, and training level on the performance of the operators in the execution of computerized EOPs. One simulated computerized EOP system was developed to present two EOPs, each with different task complexity levels, by two presentation styles (Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination). Forty subjects participated in the experiment of EOP execution using the simulated system. Statistical analysis of the experimental results indicates that: (1) complexity, presentation style, and training level all can significantly influence the error rate. High-complexity tasks and lack of sufficient training may lead to a higher error rate. Style B caused a significantly higher error rate than style A did in the skilled phase. So the designers of computerized procedures should take the presentation styles of EOPs into account. (2) Task complexity and training level can significantly influence operation time. No significant difference was found in operation time between the two presentation styles. (3) Training level can also significantly influence the subjective workload of EOPs operations. This implies that adequate training is very important for the performance of computerized EOPs even if emergency responses with computerized EOPs are much more simple and easy than that with paper-based EOPs

  8. An ergonomics study of computerized emergency operating procedures: Presentation style, task complexity, and training level

    Energy Technology Data Exchange (ETDEWEB)

    Xu Song; Song Fei [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Li Zhizhong [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)], E-mail: zzli@tsinghua.edu.cn; Zhao Qianyi; Luo Wei [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); He Xuhong [Scanpower Risk Management China Inc., Towercrest International Plaza, No. 3 Maizidian West Road, Chaoyang District, Beijing 100016 (China); Salvendy, Gavriel [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)

    2008-10-15

    Emergency operating procedures (EOPs) are widely used in nuclear power plants (NPPs). With the development of information technology, computerized EOPs are taking the place of paper-based ones. Unlike paper-based EOPs, the industrial practice of computerized EOPs is still quite limited. Ergonomics issues of computerized EOPs have not been studied adequately. This study focuses on the effects of EOP presentation style, task complexity, and training level on the performance of the operators in the execution of computerized EOPs. One simulated computerized EOP system was developed to present two EOPs, each with different task complexity levels, by two presentation styles (Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination). Forty subjects participated in the experiment of EOP execution using the simulated system. Statistical analysis of the experimental results indicates that: (1) complexity, presentation style, and training level all can significantly influence the error rate. High-complexity tasks and lack of sufficient training may lead to a higher error rate. Style B caused a significantly higher error rate than style A did in the skilled phase. So the designers of computerized procedures should take the presentation styles of EOPs into account. (2) Task complexity and training level can significantly influence operation time. No significant difference was found in operation time between the two presentation styles. (3) Training level can also significantly influence the subjective workload of EOPs operations. This implies that adequate training is very important for the performance of computerized EOPs even if emergency responses with computerized EOPs are much more simple and easy than that with paper-based EOPs.

  9. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    Science.gov (United States)

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  10. Computerization of atomic level and transition data for the first and second ionization states of the elements hydrogen through phosphorous

    International Nuclear Information System (INIS)

    Henry, E.A.

    1976-01-01

    A computerized data base of atomic energy levels and atomic transition data has been developed from data published by the National Bureau of Standards. These data are of potential use for laser application. The MASTER CONTROL data-base management system is used. These computerized data can be requested from the ERDA Computer Program Exchange and Information Center of the Argonne National Laboratory or from the National Technical Information Service of the U.S. Department of Commerce

  11. Computerized tomography of intracranial tumors

    International Nuclear Information System (INIS)

    Hungenberg, T.

    1982-01-01

    The author discusses the possibilities and limits of CT in the differential diagnosis of intracranial tumours. His discussion is based on a quantitative classification and a number of case studies selected under the following aspects: Misinterpretation of the CT image; specific diagnostic problems; uncommon CT image of the tumour; rare histological findings. 118 patients were examined between November 1976 and April 1979. (orig./MG) [de

  12. Quality of referral: What information should be included in a request for diagnostic imaging when a patient is referred to a clinical radiologist?

    Science.gov (United States)

    G Pitman, Alexander

    2017-06-01

    Referral to a clinical radiologist is the prime means of communication between the referrer and the radiologist. Current Australian and New Zealand government regulations do not prescribe what clinical information should be included in a referral. This work presents a qualitative compilation of clinical radiologist opinion, relevant professional recommendations, governmental regulatory positions and prior work on diagnostic error to synthesise recommendations on what clinical information should be included in a referral. Recommended requirements on what clinical information should be included in a referral to a clinical radiologist are as follows: an unambiguous referral; identity of the patient; identity of the referrer; and sufficient clinical detail to justify performance of the diagnostic imaging examination and to confirm appropriate choice of the examination and modality. Recommended guideline on the content of clinical detail clarifies when the information provided in a referral meets these requirements. High-quality information provided in a referral allows the clinical radiologist to ensure that exposure of patients to medical radiation is justified. It also minimises the incidence of perceptual and interpretational diagnostic error. Recommended requirements and guideline on the clinical detail to be provided in a referral to a clinical radiologist have been formulated for professional debate and adoption. © 2017 The Royal Australian and New Zealand College of Radiologists.

  13. ICT diagnostic method of beryllium welding quality

    International Nuclear Information System (INIS)

    Sun Lingxia; Wei Kentang; Ye Yunchang

    2002-01-01

    To avoid the interference of high density material for the quality assay of beryllium welding line, a slice by slice scanning method was proposed based upon the research results of the Industrial Computerized Tomography (ICT) diagnostics for weld penetration, weld width, off-centered deviation and weld defects of beryllium-ring welding seam with high density material inside

  14. Knowledge based diagnostics in nuclear power plants

    International Nuclear Information System (INIS)

    Baldeweg, F.; Fiedler, U.; Weiss, F.P.; Werner, M.

    1987-01-01

    In this paper a special process diagnostic system (PDS) is presented. It must be seen as the result of a long term work on computerized process surveillance and control; it includes a model based system for noise analysis of mechanical vibrations, which has recently been enhanced by using of knowledge based technique (expert systems). The paper discusses the process diagnostic frame concept and emphasize the vibration analysis expert system

  15. Improving the utility of the fine motor skills subscale of the comprehensive developmental inventory for infants and toddlers: a computerized adaptive test.

    Science.gov (United States)

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Chou, Willy; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2017-07-27

    This study aimed at improving the utility of the fine motor subscale of the comprehensive developmental inventory for infants and toddlers (CDIIT) by developing a computerized adaptive test of fine motor skills. We built an item bank for the computerized adaptive test of fine motor skills using the fine motor subscale of the CDIIT items fitting the Rasch model. We also examined the psychometric properties and efficiency of the computerized adaptive test of fine motor skills with simulated computerized adaptive tests. Data from 1742 children with suspected developmental delays were retrieved. The mean scores of the fine motor subscale of the CDIIT increased along with age groups (mean scores = 1.36-36.97). The computerized adaptive test of fine motor skills contains 31 items meeting the Rasch model's assumptions (infit mean square = 0.57-1.21, outfit mean square = 0.11-1.17). For children of 6-71 months, the computerized adaptive test of fine motor skills had high Rasch person reliability (average reliability >0.90), high concurrent validity (rs = 0.67-0.99), adequate to excellent diagnostic accuracy (area under receiver operating characteristic = 0.71-1.00), and large responsiveness (effect size = 1.05-3.93). The computerized adaptive test of fine motor skills used 48-84% fewer items than the fine motor subscale of the CDIIT. The computerized adaptive test of fine motor skills used fewer items for assessment but was as reliable and valid as the fine motor subscale of the CDIIT. Implications for Rehabilitation We developed a computerized adaptive test based on the comprehensive developmental inventory for infants and toddlers (CDIIT) for assessing fine motor skills. The computerized adaptive test has been shown to be efficient because it uses fewer items than the original measure and automatically presents the results right after the test is completed. The computerized adaptive test is as reliable and valid as the CDIIT.

  16. Computerized provider order entry in the clinical laboratory

    Science.gov (United States)

    Baron, Jason M.; Dighe, Anand S.

    2011-01-01

    Clinicians have traditionally ordered laboratory tests using paper-based orders and requisitions. However, paper orders are becoming increasingly incompatible with the complexities, challenges, and resource constraints of our modern healthcare systems and are being replaced by electronic order entry systems. Electronic systems that allow direct provider input of diagnostic testing or medication orders into a computer system are known as Computerized Provider Order Entry (CPOE) systems. Adoption of laboratory CPOE systems may offer institutions many benefits, including reduced test turnaround time, improved test utilization, and better adherence to practice guidelines. In this review, we outline the functionality of various CPOE implementations, review the reported benefits, and discuss strategies for using CPOE to improve the test ordering process. Further, we discuss barriers to the implementation of CPOE systems that have prevented their more widespread adoption. PMID:21886891

  17. Computerized provider order entry in the clinical laboratory

    Directory of Open Access Journals (Sweden)

    Jason M Baron

    2011-01-01

    Full Text Available Clinicians have traditionally ordered laboratory tests using paper-based orders and requisitions. However, paper orders are becoming increasingly incompatible with the complexities, challenges, and resource constraints of our modern healthcare systems and are being replaced by electronic order entry systems. Electronic systems that allow direct provider input of diagnostic testing or medication orders into a computer system are known as Computerized Provider Order Entry (CPOE systems. Adoption of laboratory CPOE systems may offer institutions many benefits, including reduced test turnaround time, improved test utilization, and better adherence to practice guidelines. In this review, we outline the functionality of various CPOE implementations, review the reported benefits, and discuss strategies for using CPOE to improve the test ordering process. Further, we discuss barriers to the implementation of CPOE systems that have prevented their more widespread adoption.

  18. Computerized occlusal analysis in bruxism

    Directory of Open Access Journals (Sweden)

    Lazić Vojkan

    2006-01-01

    Full Text Available Introduction. Sleep bruxism as nocturnal parafunction, also known as tooth grinding, is the most common parasomnia (sleep disorder. Most tooth grinding occurs during rapid eye movement - REM sleep. Sleep bruxism is an oral habit characterized by rhythmic activity of the masticatory muscles (m. masseter that causes forced contact between dental surfaces during sleep. Sleep bruxism has been associated with craniomandibular disorders including temporomandibular joint discomfort, pulpalgia, premature loss of teeth due to excessive attrition and mobility, headache, muscle ache, sleep interruption of an individual and problems with removable and fixed denture. Basically, two groups of etiological factors can be distinguished, viz., peripheral (occlusal factors and central (pathophysiological and psychological factors. The role of occlusion (occlusal discrepancies as the causative factor is not enough mentioned in relation to bruxism. Objective. The main objective of this paper was to evaluate the connection between occlusal factors and nocturnal parafunctional activities (occlusal disharmonies and bruxism. Method. Two groups were formed- experimental of 15 persons with signs and symptoms of nocturnal parafunctional activity of mandible (mean age 26.6 years and control of 42 persons with no signs and symptoms of bruxism (mean age 26.3 yrs.. The computerized occlusal analyses were performed using the T-Scan II system (Tekscan, Boston, USA. 2D occlusograms were analyzed showing the occlusal force, the center of the occlusal force with the trajectory and the number of antagonistic tooth contacts. Results. Statistically significant difference of force distribution was found between the left and the right side of the arch (L%-R% (t=2.773; p<0.02 in the group with bruxism. The difference of the centre of occlusal force - COF trajectory between the experimental and control group was not significant, but the trajectory of COF was longer in the group of

  19. Formal Verification of Computerized Procedure with Colored Petri Nets

    International Nuclear Information System (INIS)

    Kim, Yun Goo; Shin, Yeong Cheol

    2008-01-01

    Computerized Procedure System (CPS) supports nuclear power plant operators in performing operating procedures which are instructions to guide in monitoring, decision making and controlling nuclear power plants. Computerized Procedure (CP) should be loaded to CPS. Due to its execution characteristic, computerized procedure acts like a software in CPS. For example, procedure flows are determined by operator evaluation and computerized procedure logic which are pre-defined. So the verification of Computerized Procedure logic and execution flow is needed before computerized procedures are installed in the system. Formal verification methods are proposed and the modeling of operating procedures with Coloured Petri Nets(CP-nets) is presented

  20. A unified plant information network

    International Nuclear Information System (INIS)

    Niederauer, G.F.

    1986-01-01

    Technology is bringing power plants fully into the age of computerization. Microcomputers, data base managers, networking, and friendly, expert software are principal technology factors. Monitoring will improve, and the number and power of computers is increasing. The huge information flow will cause computers to be integrated into a communication network. The total plant operating triangle includes process, engineering, and management systems. The total network will integrate all of these into a Total Unified Plant Information Network (TUPIN). Software will take the type of information beyond monitored data. Analysis will improve through direct access to logical, physical, and procedural models by end users. Information management will improve through widespread use of hierarchical, relational, and expert data base managers. Expert systems will aid in diagnostics and interpretation. The goal is to automate plant operations to enhance safety and performance and to reduce cost by making both the plants and the personnel more expert

  1. Vision-based building energy diagnostics and retrofit analysis using 3D thermography and building information modeling

    Science.gov (United States)

    Ham, Youngjib

    The emerging energy crisis in the building sector and the legislative measures on improving energy efficiency are steering the construction industry towards adopting new energy efficient design concepts and construction methods that decrease the overall energy loads. However, the problems of energy efficiency are not only limited to the design and construction of new buildings. Today, a significant amount of input energy in existing buildings is still being wasted during the operational phase. One primary source of the energy waste is attributed to unnecessary heat flows through building envelopes during hot and cold seasons. This inefficiency increases the operational frequency of heating and cooling systems to keep the desired thermal comfort of building occupants, and ultimately results in excessive energy use. Improving thermal performance of building envelopes can reduce the energy consumption required for space conditioning and in turn provide building occupants with an optimal thermal comfort at a lower energy cost. In this sense, energy diagnostics and retrofit analysis for existing building envelopes are key enablers for improving energy efficiency. Since proper retrofit decisions of existing buildings directly translate into energy cost saving in the future, building practitioners are increasingly interested in methods for reliable identification of potential performance problems so that they can take timely corrective actions. However, sensing what and where energy problems are emerging or are likely to emerge and then analyzing how the problems influence the energy consumption are not trivial tasks. The overarching goal of this dissertation focuses on understanding the gaps in knowledge in methods for building energy diagnostics and retrofit analysis, and filling these gaps by devising a new method for multi-modal visual sensing and analytics using thermography and Building Information Modeling (BIM). First, to address the challenges in scaling and

  2. Computerized tomography in the diagnosis of mechanical jaundice

    International Nuclear Information System (INIS)

    Grushin, Yu.V.; Manasov, T.Zh.; Raskolenko, A.A.; Nazyrova, N.K.; Dzhumashev, E.Z.

    1987-01-01

    A total of 51 patients with suspected mechanical jaundice were examined using the 3rd generation computerized tomograph. A correct conclusion as to the level and mechanism of obstruction was made in 77% of cases. The most serious problems arose in analysis of extrahepatic biliary ducts. The dilatation of the biliary passages was not always combined with their obturation. In cases which were difficult for interpretation, additional information could be obtained by using thin tomographic layers, i.v. contrast enhancement, and retrograde endoscopic cholangiography

  3. The computerized point of order processing at the dairying plant

    OpenAIRE

    Pankauskienė, Dalia

    2007-01-01

    Darbe išanalizuota IS kūrimo principai ir problemos, pieno perdirbimo įmonės veikla. Pasirinktos užsakymų priėmimo sistemos projektavimo ir projekto realizavimo priemonės. Atliktas užsakymų priėmimo IS projektavimas. Sukurta duomenų bazė, kurios pagalba suprojektuota užsakymų priėmimo kompiuterizuota darbo vieta pieno perdirbimo įmonėje. Company’s business computerization stands for creating and installing an information system which would satisfy all company’s needs. Such system’s creatio...

  4. Core on-line monitoring and computerized procedures systems

    International Nuclear Information System (INIS)

    Gangloff, W.C.

    1986-01-01

    The availability of operating nuclear power plants has been affected significantly by the difficulty people have in coping with the complexity of the plants and the operating procedures. Two ways to use modern computer technology to ease the burden of coping are discussed in this paper, an on-line core monitoring system with predictive capability and a computerized procedures system using live plant data. These systems reduce human errors by presenting information rather than simply data, using the computer to manipulate the data, but leaving the decisions to the plant operator

  5. The evolution of computerized displays in accident management

    International Nuclear Information System (INIS)

    DeBor, J.

    1988-01-01

    Key regulations implemented by the NRC in 1982, which included requirements such as upgraded emergency operating procedures, detailed control room design reviews, the addition of a safety parameter display system, and the inclusion of a degreed shift technical advisor as part of the operating staff, have enabled the use of computerized displays to evolve as an integral part of accident management within each of the four main vendor groups. Problems, however, remain to be resolved in the area of technical content, information reliability, and rules for use in order to achieve the goal of more reliable accident management in nuclear power plants

  6. 2D histomorphometric quantification from 3D computerized tomography

    International Nuclear Information System (INIS)

    Lima, Inaya; Oliveira, Luis Fernando de; Lopes, Ricardo T.; Jesus, Edgar Francisco O. de; Alves, Jose Marcos

    2002-01-01

    In the present article, preliminary results are presented showing the application of the tridimensional computerized microtomographic technique (3D-μCT) to bone tissue characterization, through histomorphometric quantification which are based on stereologic concepts. Two samples of human bone were correctly prepared to be submitted to the tomographic system. The system used to realize that process were a radiographic system with a microfocus X-ray tube. Through these three processes, acquisition, reconstruction and quantification, it was possible to get the good results and coherent to the literature data. From this point, it is intended to compare these results with the information due the conventional method, that is, conventional histomorphometry. (author)

  7. Pocket book on setting techniques for medical imaging. X-ray diagnostics, angiography, CT, MRT. 4. rev. and enl. ed.; Taschenatlas Einstelltechnik. Roentgendiagnostik, Angiografie, CT, MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Torsten B.; Reif, Emil [Caritas-Krankenhaus, Dillingen/Saar (Germany)

    2009-07-01

    The pocketbook on setting techniques for medical imaging is concerned with the problem to prepare appropriate images for diagnostic purposes using modern high-technology instruments like x-ray diagnostics, angiography, computerized tomography and magnetic resonance tomography. The following issues are covered: Head, spinal column, upper extremities, lower extremities, thorax, gastrointestinal tract, intravenous organ examination, angiography, computerized tomography, NMR imaging.

  8. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Remacle, J.; Quoidbach, G.

    1993-01-01

    The concept of 'computerized management' of plant intervention tasks was developed by TRACTEBEL in 1983 for the Belgian power plants of ELECTRABEL. The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant in planning, organizing, and carrying out any (preventive or corrective) maintenance task. It consists of a group of interconnected functional modules acting on a unique and homogeneous data base. A short description of 3 modules is given, i.e., the 'User' Module, the 'Equipment' Module and the 'Periodic Procedure' Module. (Z.S.)

  9. MEDICAL DIAGNOSTICS BY MICROSTRUCTURAL ANALYSIS OF BIOLOGICAL LIQUID DRIED PATTERNS AS A PROBLEM OF BIOINFORMATICS

    Directory of Open Access Journals (Sweden)

    Petr Vladimirovich Lebedev-Stepanov, Dr.

    2018-02-01

    Full Text Available Motivation: It is important to develop the high-precision computerized methods for medical rapid diagnostic which is generalizing the unique clinical experience obtained in the past decade as specialized solutions for diagnostic problems of control of specific diseases and, potentially, for a wide health monitoring of virtually healthy population, identify the reserves of human health and take the actions to prevent of these reserves depletion. In this work we present one of the new directions in bioinformatics, i.e. medical diagnostics by automated expert system on basis of morphology analysis of digital image of biological liquid dried pattern. Results: Proposed method is combination of bioinformatics and biochemistry approaches for obtaining diagnostic information from a morphological analysis of standardized dried patterns of biological liquid sessile drop. We have carried out own research in collaboration with medical diagnostic centers and formed the electronic database for recognition the following types of diseases: candidiasis; neoplasms; diabetes mellitus; diseases of the circulatory system; cerebrovascular disease; diseases of the digestive system; diseases of the genitourinary system; infectious diseases; factors relevant to the work; factors associated with environmental pollution; factors related to lifestyle. The laboratory setup for diagnostics of the human body in pathology states is developed. The diagnostic results are considered. Availability: Access to testing the software can be obtained on request to the contact email below.

  10. Computerized tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Delouvrier, J.J.; Tritschler, J.L.; Desbleds, M.T.; Cambier, J.; Nahum, H.

    1980-01-01

    The double scan CT method was applied to a homogeneous population of 50 multiple sclerosis patients and the following features were studied: well defined low-density areas, localized contrast enhancements, cerebral atrophy and white matter homogeneity. The analyses of the variance of the white matter (centrum ovale) can disclose those lesions which individually do not surpass the visibility threshold. The lesions that are localized in the white matter are mainly periventricular, most often multiple, and they do not displace the neighbouring structures. By revealing a large number of clinically silent cerebral lesions, the cerebral CT becomes a highly important diagnostic tool. The value of the CT examinations seems to be of major importance each time that the clinical diagnosis is hesitant, particularly when faced with medullary signs or an initial neurological episode. (C.F.)

  11. Critical factors influencing physicians' intention to use computerized clinical practice guidelines: an integrative model of activity theory and the technology acceptance model.

    Science.gov (United States)

    Hsiao, Ju-Ling; Chen, Rai-Fu

    2016-01-16

    With the widespread use of information communication technologies, computerized clinical practice guidelines are developed and considered as effective decision supporting tools in assisting the processes of clinical activities. However, the development of computerized clinical practice guidelines in Taiwan is still at the early stage and acceptance level among major users (physicians) of computerized clinical practice guidelines is not satisfactory. This study aims to investigate critical factors influencing physicians' intention to computerized clinical practice guideline use through an integrative model of activity theory and the technology acceptance model. The survey methodology was employed to collect data from physicians of the investigated hospitals that have implemented computerized clinical practice guidelines. A total of 505 questionnaires were sent out, with 238 completed copies returned, indicating a valid response rate of 47.1 %. The collected data was then analyzed by structural equation modeling technique. The results showed that attitudes toward using computerized clinical practice guidelines (γ = 0.451, p technology) factors mentioned in the activity theory should be carefully considered when introducing computerized clinical practice guidelines. Managers should pay much attention on those identified factors and provide adequate resources and incentives to help the promotion and use of computerized clinical practice guidelines. Through the appropriate use of computerized clinical practice guidelines, the clinical benefits, particularly in improving quality of care and facilitating the clinical processes, will be realized.

  12. Robinson's Computerized Strabismus Model Comes of Age

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); H. Spekreijse (Henk)

    1996-01-01

    textabstractIn this article we review our further development of D.A. Robinson's computerized strabismus model. First, an extensive literature study has been carried out to get more accurate data on the anatomy of the average eye and the eye muscles, and about how these vary with age and with

  13. Computerized Italian criticality guide, description and validation

    International Nuclear Information System (INIS)

    Carotenuto, M.; Landeyro, P.A.

    1988-10-01

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  14. Some procedures for computerized ability testing

    NARCIS (Netherlands)

    van der Linden, Willem J.; Zwarts, Michel A.

    1989-01-01

    For computerized test systems to be operational, the use of item response theory is a prerequisite. As opposed to classical test theory, in item response models the abilities of the examinees and the properties of the items are parameterized separately. Hence, when measuring the abilities of

  15. Implementation of a Computerized Maintenance Management System

    Science.gov (United States)

    Shen, Yong-Hong; Askari, Bruce

    1994-01-01

    A primer Computerized Maintenance Management System (CMMS) has been established for NASA Ames pressure component certification program. The CMMS takes full advantage of the latest computer technology and SQL relational database to perform periodic services for vital pressure components. The Ames certification program is briefly described and the aspects of the CMMS implementation are discussed as they are related to the certification objectives.

  16. Computerizing Maintenance Management Improves School Processes.

    Science.gov (United States)

    Conroy, Pat

    2002-01-01

    Describes how a Computerized Maintenance Management System (CMMS), a centralized maintenance operations database that facilitates work order procedures and staff directives, can help individual school campuses and school districts to manage maintenance. Presents the benefits of CMMS and things to consider in CMMS selection. (EV)

  17. The limited angle problem in computerized tomography

    International Nuclear Information System (INIS)

    Louis, A.K.

    1984-01-01

    Fast reconstruction formulae in X-ray computerized tomography demand the directions, in which the measurements are taken, to be equally distributed over the whole circle. In many applications data can only be provided in a restricted range. Here the intrinsic difficulties are studied by giving a singular value decomposition of the Radon transform in a restricted range. Practical limitations are deduced. (orig.)

  18. Ethics and the Computerization of Pharmacy.

    Science.gov (United States)

    McCarthy, Robert L.; Perrolle, Judith A.

    1991-01-01

    The current and potential impact of computerization on pharmacy practice is discussed, focusing on ethical dilemmas in the pharmacist-patient relationship, confidentiality of records, and the role of artificial intelligence in decision making about drug therapy. Case studies for use by teachers of pharmaceutical ethics are provided. (Author/MSE)

  19. Individual Differences in Computerized Adaptive Testing.

    Science.gov (United States)

    Kim, JinGyu

    Research on the major computerized adaptive testing (CAT) strategies is reviewed, and some findings are reported that examine effects of examinee demographic and psychological characteristics on CAT strategies. In fixed branching strategies, all examinees respond to a common routing test, the score of which is used to assign examinees to a…

  20. Computerized management support for swine breeding farms

    NARCIS (Netherlands)

    Huirne, R.B.M.

    1990-01-01

    1. INTRODUCTION

    The investigations described in this thesis have been directed towards computerized management support for swine breeding farms, focused on sow productivity and profitability. The study is composed of three basic parts: (1) basic description and

  1. The Computerized Reference Department: Buying the Future.

    Science.gov (United States)

    Kriz, Harry M.; Kok, Victoria T.

    1985-01-01

    Basis for systematic computerization of academic research library's reference, collection development, and collection management functions emphasizes productivity enhancement for librarians and support staff. Use of microcomputer and university's mainframe computer to develop applications of database management systems, electronic spreadsheets,…

  2. Computerized system for measuring cerebral metabolism

    International Nuclear Information System (INIS)

    McGlone, J.S.; Hibbard, L.S.; Hawkins, R.A.; Kasturi, R.

    1987-01-01

    A computerized stereotactic measurement system for evaluating rat brain metabolism was developed to utilize the large amount of data generated by quantitative autoradiography. Conventional methods of measurement only analyze a small percent of these data because these methods are limited by instrument design and the subjectiveness of the investigator. However, a computerized system allows digital images to be analyzed by placing data at their appropriate three-dimensional stereotactic coordinates. The system automatically registers experimental data to a standard three-dimensional image using alignment, scaling, and matching operations. Metabolic activity in different neuronal structures is then measured by generating digital masks and superimposing them on to experimental data. Several experimental data sets were evaluated and it was noticed that the structures measured by the computerized system, had in general, lower metabolic activity than manual measurements had indicated. This was expected because the computerized system measured the structure over its volume while the manual readings were taken from the most active metabolic area of a particular structure

  3. Computerized Italian criticality guide, description and validation

    Energy Technology Data Exchange (ETDEWEB)

    Carotenuto, M; Landeyro, P A [ENEA - Dipartimento Ciclo del Combustibile, Centro Ricerche Energia, Casaccia (Italy)

    1988-10-15

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  4. Geometrical efficiency in computerized tomography: generalized model

    International Nuclear Information System (INIS)

    Costa, P.R.; Robilotta, C.C.

    1992-01-01

    A simplified model for producing sensitivity and exposure profiles in computerized tomographic system was recently developed allowing the forecast of profiles behaviour in the rotation center of the system. The generalization of this model for some point of the image plane was described, and the geometrical efficiency could be evaluated. (C.G.C.)

  5. Computerized reactor monitor and control for research reactors

    International Nuclear Information System (INIS)

    Buerger, L.; Vegh, E.

    1981-09-01

    The computerized process control system developed in the Central Research Institute for Physics, Budapest, Hungary, is described together with its special applications at research reactors. The nuclear power of the Hungarian research reactor is controlled by this computerized system, too, while in Lybia many interesting reactor-hpysical calculations are built into the computerized monitor system. (author)

  6. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  7. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Data manual

    International Nuclear Information System (INIS)

    Gilbert, B.G.; Reece, W.J.; Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.

    1990-12-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal computer. NUCLARR can furnish the end user with data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented is a five-volume series of reports. Volume V: Data Manual provides a hard-copy representation of all data and related information available within the NUCLARR system software. This document is organized in three sections. Part 1 is the summary description, which presents an overview of the NUCLARR system and data processing procedures. Part 2 contains all data and information relevant to the human error probability (HEP) data side of NUCLARR. Data and information for the hardware component failure data (HCFD) side are presented in Part 3. 7 refs

  8. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR)

    International Nuclear Information System (INIS)

    Gilbert, B.G.; Reece, W.J.; Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.

    1990-12-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal computer. NUCLARR can furnish the end user with data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume 5: Data Manual provides a hard-copy representation of all data and related information available within the NUCLARR system software. This document is organized in three sections. Part 1 is the summary description, which presents an overview of the NUCLARR system and data processing procedures. Part 2 contains all data and information relevant to the human error probability (HEP) data side of NUCLARR. Data and information for the hardware component failure data (HCFD) side are presented in Part 3. 7 refs

  9. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Data manual

    International Nuclear Information System (INIS)

    Gilbert, B.G.; Reece, W.J.; Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.

    1990-12-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal computer. NUCLARR can furnish the end user with data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume V: Data Manual provides a hard-copy representation of all data and related information available within the NUCLARR system software. This document is organized in three sections. Part 1 is the summary description, which presents an overview of the NUCLARR system and data processing procedures. Part 2 contains all data and information relevant to the human error probability (HEP) side of NUCLARR. Data and information for the hardware component failure data (HCFD) side are presented in Part 3. 7 refs., 1 fig

  10. Serum peptide/protein profiling by mass spectrometry provides diagnostic information independently of CA125 in women with an ovarian tumor

    DEFF Research Database (Denmark)

    Callesen, Anne; Madsen, Jonna S; Iachina, Maria

    2010-01-01

    In the present study, the use of a robust and sensitive mass spectrometry based protein profiling analysis was tested as diagnostic tools for women with an ovarian tumor. The potential additional diagnostic value of serum protein profiles independent of the information provided by CA125 were also...... investigated. Protein profiles of 113 serum samples from women with an ovarian tumor (54 malign and 59 benign) were generated using MALDI-TOF MS. A total of 98 peaks with a significant difference (pwomen with benign tumors/cysts and malignant ovarian tumors were identified. After...... average linkage clustering, a profile of 46 statistical significant mass peaks was identified to distinguish malignant tumors and benign tumors/cysts. In the subgroup of women with normal CA125 values (

  11. Optimizing the Use of Response Times for Item Selection in Computerized Adaptive Testing

    Science.gov (United States)

    Choe, Edison M.; Kern, Justin L.; Chang, Hua-Hua

    2018-01-01

    Despite common operationalization, measurement efficiency of computerized adaptive testing should not only be assessed in terms of the number of items administered but also the time it takes to complete the test. To this end, a recent study introduced a novel item selection criterion that maximizes Fisher information per unit of expected response…

  12. 'High resolution' computerized tomography in spinal narrow and spinal column diagnosis

    International Nuclear Information System (INIS)

    Koester, O.

    1985-01-01

    Bearing in mind that direct comparison is lacking, high resolution computerized tomography in spinal column diagnosis can be said to supply considerably increased information when dealing with the issues of a cervical prolapse and bony changes of any origin. Its advantages appear to be reduced when assessing lumbar prolapse, intraspinal masses and paravertebral soft-tissue processes. (orig.) [de

  13. Status of routine post-mortem computerized tomography in Odense, Denmark

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2008-01-01

    rarely is a substitute for autopsy, but may contribute with important new information in many cases such as identifications (including mass-disasters), battered child, gunshot wounds, traffic accidents and air embolism. Computerized tomography provides documentation in digital form - easily stored...

  14. Computerized study with 201Tl of the gold thyroid node

    International Nuclear Information System (INIS)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-01-01

    Because of its physical and potassium-metabolic characteristics 201 Tl is more suitable than 131 Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 μCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201 Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201 Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index. (orig.) [de

  15. Computerized Decision Aids for Shared Decision Making in Serious Illness: Systematic Review.

    Science.gov (United States)

    Staszewska, Anna; Zaki, Pearl; Lee, Joon

    2017-10-06

    Shared decision making (SDM) is important in achieving patient-centered care. SDM tools such as decision aids are intended to inform the patient. When used to assist in decision making between treatments, decision aids have been shown to reduce decisional conflict, increase ease of decision making, and increase modification of previous decisions. The purpose of this systematic review is to assess the impact of computerized decision aids on patient-centered outcomes related to SDM for seriously ill patients. PubMed and Scopus databases were searched to identify randomized controlled trials (RCTs) that assessed the impact of computerized decision aids on patient-centered outcomes and SDM in serious illness. Six RCTs were identified and data were extracted on study population, design, and results. Risk of bias was assessed by a modified Cochrane Risk of Bias Tool for Quality Assessment of Randomized Controlled Trials. Six RCTs tested decision tools in varying serious illnesses. Three studies compared different computerized decision aids against each other and a control. All but one study demonstrated improvement in at least one patient-centered outcome. Computerized decision tools may reduce unnecessary treatment in patients with low disease severity in comparison with informational pamphlets. Additionally, electronic health record (EHR) portals may provide the opportunity to manage care from the home for individuals affected by illness. The quality of decision aids is of great importance. Furthermore, satisfaction with the use of tools is associated with increased patient satisfaction and reduced decisional conflict. Finally, patients may benefit from computerized decision tools without the need for increased physician involvement. Most computerized decision aids improved at least one patient-centered outcome. All RCTs identified were at a High Risk of Bias or Unclear Risk of Bias. Effort should be made to improve the quality of RCTs testing SDM aids in serious

  16. [Computerized clinical protocol for occlusion].

    Science.gov (United States)

    Salsench, J; Ferrer, J; Nogueras, J

    1988-11-01

    In making a protocol it is necessary that all members of the team who are going to collect information have the same unity of criterion about the different variables that compose it. The drawing up of this document is as much or more necessary than the protocol itself. In this work we all data collected in the protocol and we give the explanations of each concept.

  17. Computerized bioterrorism education and training for nurses on bioterrorism attack agents.

    Science.gov (United States)

    Nyamathi, Adeline M; Casillas, Adrian; King, Major L; Gresham, Louise; Pierce, Elaine; Farb, Daniel; Wiechmann, Carrie; Weichmann, Carrie

    2010-08-01

    Biological agents have the ability to cause large-scale mass casualties. For this reason, their likely use in future terrorist attacks is a concern for national security. Recent studies show that nurses are ill prepared to deal with agents used in biological warfare. Achieving a goal for bioterrorism preparedness is directly linked to comprehensive education and training that enables first-line responders such as nurses to diagnose infectious agents rapidly. The study evaluated participants' responses to biological agents using a computerized bioterrorism education and training program versus a standard bioterrorism education and training program. Both programs improved participants' ability to complete and solve case studies involving the identification of specific biological agents. Participants in the computerized bioterrorism education and training program were more likely to solve the cases critically without reliance on expert consultants. However, participants in the standard bioterrorism education and training program reduced the use of unnecessary diagnostic tests.

  18. A case of multiple intracranial tuberculoma followed by serial computerized tomography

    International Nuclear Information System (INIS)

    Kummer, R. von; Storch, B.; Krause, K.H.; Rauch, H.

    1981-01-01

    This is the case report of an Indian living in Europe who suffered from multiple cerebral tuberculomes in connexion with extrapulmonal tuberculosis. The retrogression of the inflammatory granulomes and the surrounding cerebral edema by treatment with tuberculostatics and Dexamethasone was observed by means of computerized tomography (CT) over a period of 8 months. The value of CT in the diagnosis and treatment of cerebral tuberculomes is discussed. The diagnosis of cerebral tuberculomes is difficult as neither the clinical picture nor additional neuroradiological tests ensure safe delimitation against other intracranial growths. In how far this situation has changed by the introduction of CT into diagnostics is discussed by the example of serial computerized tomography on a patient with multiple cerebral tuberculomes. (orig.) [de

  19. Effective Heart Disease Detection Based on Quantitative Computerized Traditional Chinese Medicine Using Representation Based Classifiers

    Directory of Open Access Journals (Sweden)

    Ting Shu

    2017-01-01

    Full Text Available At present, heart disease is the number one cause of death worldwide. Traditionally, heart disease is commonly detected using blood tests, electrocardiogram, cardiac computerized tomography scan, cardiac magnetic resonance imaging, and so on. However, these traditional diagnostic methods are time consuming and/or invasive. In this paper, we propose an effective noninvasive computerized method based on facial images to quantitatively detect heart disease. Specifically, facial key block color features are extracted from facial images and analyzed using the Probabilistic Collaborative Representation Based Classifier. The idea of facial key block color analysis is founded in Traditional Chinese Medicine. A new dataset consisting of 581 heart disease and 581 healthy samples was experimented by the proposed method. In order to optimize the Probabilistic Collaborative Representation Based Classifier, an analysis of its parameters was performed. According to the experimental results, the proposed method obtains the highest accuracy compared with other classifiers and is proven to be effective at heart disease detection.

  20. [Parenting stress and the reliability of parental information in the diagnostics of children and adolescents with symptoms of psychiatric and behavioral disorders].

    Science.gov (United States)

    Irlbauer-Müller, Viktoria; Eichler, Anna; Stemmler, Mark; Moll, Gunther H; Kratz, Oliver

    2017-07-01

    Information from parents is regularly used in the diagnostic process of children and adolescents with psychiatric symptoms. But the reliability of this information is debatable, because the parents’ own stress can distort their perceptions of the child’s symptoms. For each of N = 68 children and adolescents (11–18 years) who were using mental health services for the first time, we evaluated the ratings of a parent and a professional clinician (internalizing, externalizing symptoms, total-problem score). In addition, parenting stress was scored on the Eltern-Belastungs-Inventars (EBI, Tröster, 2011), which measures both child-related stress and parent-related stress as well as total stress. Highly stressed parent ratings differed more from the clinicians’ ratings than the ratings of less stressed parents. Additionally, correlations showed that higher parenting stress resulted in larger differences between the parent’s and the clinician’s assessments. Multiple regressions proved the predictive value of child-caused parenting stress for these differences. These results apply for internalizing symptoms, externalizing symptoms, and total-problem score. Parenting stress should be evaluated systematically in order to carefully assess the value of the information from parents and to determine how it should be included in diagnostic and therapeutical decisions.

  1. Assessment of Minimal HE (with emphasis on computerized psychometric tests)

    Science.gov (United States)

    Kappus, Matthew R; Bajaj, Jasmohan S

    2012-01-01

    Synopsis Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life and driving accidents. The detection of MHE requires specialized testing since it cannot by definition, be diagnosed on standard clinical examination. Psychometric (paper-pencil or computerized or a combination) and neuro-physiological techniques are often used to test for MHE. Paper-pencil psychometric batteries like the Psychometric Hepatic Encephalopathy Score (PHES) have been validated in several countries but do not have US normative values. Computerized tests such as the inhibitory control test (ICT), cognitive drug research system and Scan test have proven useful to diagnose MHE and predict outcomes. The specificity and sensitivity of these tests are similar to the recommended gold standards. Neuro-physiological tests such as the EEG and its interpretations, evoked potentials and Critical Flicker Frequency (CFF) also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike and the testing strategies depend on the normative data available, patient comfort and local expertise. PMID:22321464

  2. Computerized classification of mass lesions in digital mammograms

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; Yin, F.F.; Schmidt, R.A.; Vyborny, C.J.

    1989-01-01

    Subjective classification of masses on mammograms is a difficult task. On average, about 25% of masses referred for surgical biopsy are actually malignant. The authors are developing, as an aid to radiologists, a computerized scheme for the classification of lesions in mammograms to reduce the false-negative and false-positive diagnoses of malignancies. The classification scheme involves the extraction of border information from the mammographic lesion in order to quantify the degree of spiculation, which is related to the possibility of malignancy. Clinical film mammograms are digitized with an optical drum scanner (0.1-mm pixel size) for analysis on a Micro VAX 3500 computer. Border information (fluctuations) is obtained from the difference between the lesion border and its smoothed border. Using the rms variation of the frequency content of these fluctuations, approximately 85% of the cancerous lesions were correctly classified as malignant, while 15% of benign lesions were misclassified, in a preliminary study

  3. Computerized tomography in atypical Pott's disease

    International Nuclear Information System (INIS)

    Cabrera, M.N.B.; Wang, E.H.M.

    1993-01-01

    Classical Pott's disease is described as a two-vertebrae disease with the destruction of the intervening invertebral disc. Computerized tomography has been used in the differential diagnosis of spine infections and neoplasms. We reviewed CT scans of patients seen at the Philippine General Hospital over a two-year period with atypical presentations of atypical tuberculous spondylitis. We used the computerized tomography findings described as characteristic of classical Pott's disease as criteria in evaluating the CT scans of patients diagnosed to have Atypical Pott's Disease. Although the number of patients prevented sensitivity and specificity studies to be done, our results strongly suggest that the same CT criteria used to diagnose Classical Pott's Disease may also be used to diagnose Pott's disease in its atypical form. (Author.). 13 refs

  4. Evidence synthesis to inform model-based cost-effectiveness evaluations of diagnostic tests: a methodological review of health technology assessments

    Directory of Open Access Journals (Sweden)

    Bethany Shinkins

    2017-04-01

    Full Text Available Abstract Background Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. Methods We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1 what evidence aside from test accuracy was searched for and synthesised, 2 which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3 how/whether threshold effects were explored, 4 how the potential dependency between multiple tests in a pathway was accounted for, and 5 for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. Results The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings

  5. Computerized flow monitors detect small kicks

    Energy Technology Data Exchange (ETDEWEB)

    McCann, D.; White, D. (Sedco Forex, Paris (FR))

    1992-02-24

    This paper reports on a smart alarm system installed on a number of offshore rigs and one land rig which can detect kicks more quickly than conventional systems. This rapid kick detection improves rig safety because the smaller the detected influx, the easier it is to control the well. The extensive computerized monitoring system helps drilling personnel detect fluid influxes and fluid losses before the changes in flow would normally be apparent.

  6. The EORTC emotional functioning computerized adaptive test

    DEFF Research Database (Denmark)

    Gamper, Eva-Maria; Grønvold, Mogens; Petersen, Morten Aa

    2014-01-01

    The European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Group is currently developing computerized adaptive testing measures for the Quality of Life Questionnaire Core-30 (QLQ-C30) scales. The work presented here describes the development of an EORTC item bank for e...... for emotional functioning (EF), which is one of the core domains of the QLQ-C30....

  7. 10 years of computerized tomography reviewed

    International Nuclear Information System (INIS)

    Duemmling, K.

    1984-01-01

    The history and some highlights of computerized tomography are reviewed. The various technologies employed in the course of CT development are described along with the limitations that led to their disappearance. The problems still to be solved in medicine, the increasing influence of nuclear magnetic resonance, and some scientific aspects have opened up new lines of development which are briefly mentioned. (orig./WU) [de

  8. Computerized reactor power regulation with logarithmic controller

    International Nuclear Information System (INIS)

    Gossanyi, A.; Vegh, E.

    1982-11-01

    A computerized reactor control system has been operating at a 5 MW WWR-SM research reactor in the Central Research Institute for Physics, Budapest, for some years. This paper describes the power controller used in the SPC operating mode of the system, which operates in a 5-decade wide power range with +-0.5% accuracy. The structure of the controller easily limits the minimal reactor period and produces a reactor transient with constant period if the power demand changes. (author)

  9. COMPRESS - a computerized reactor safety system

    International Nuclear Information System (INIS)

    Vegh, E.

    1986-01-01

    The computerized reactor safety system, called COMPRESS, provides the following services: scram initiation; safety interlockings; event recording. The paper describes the architecture of the system and deals with reliability problems. A self-testing unit checks permanently the correct operation of the independent decision units. Moreover the decision units are tested by short pulses whether they can initiate a scram. The self-testing is described in detail

  10. Computerized UT system for stud bolt

    International Nuclear Information System (INIS)

    Kisanuki, T.; Uchida, K.; Fushimi, T.; Onda, K.

    1988-01-01

    Cracking of stud bolts used in steam turbine casing, valve and pressure vessel has caused concern regarding the safety and reliability of power plants. In order to detect harmful cracks in early state, the improvement of UT technique is required. As regarding the ultrasonic inspection technique, a longitudinal beam technique and/or an angle beam technique are generally used. The authors report their development of a computerized UT system for bolt inspection and improvement of the angle beam technique

  11. Computerized dosimetry management systems within EDF

    International Nuclear Information System (INIS)

    Daubert, G.

    1996-01-01

    EDF, using the ALARA approach, has embarked an ambitious project of optimising the doses received in its power plants. In directing its choice of actions and the effectiveness of such actions, the French operator is using a computerized personal and collective dosimetry management system. This system provides for ongoing monitoring of dosimetry at personal, site and unit level or indeed for the entire population of EDF nuclear power plants. (author)

  12. Increased intracranial pressure: evaluation by computerized tomography

    International Nuclear Information System (INIS)

    Lightfoote, W.E.; Pressman, B.D.

    1975-01-01

    Computerized tomography is clearly very useful in the evaluation of patients with increased intracranial pressure and suspected pseudotumor cerebri. It provides an index of ventricular size and configuration and has the capability of demonstrating intracranial lesions. Moreover, this new technique is rapid and non-invasive, and is without attendant risks. Examinations may be performed serially as the clinical process evolves, thereby giving roentgenographic correlation to the clinical features. (U.S.)

  13. Computerized materials protection, control, and accountability

    International Nuclear Information System (INIS)

    Whiteson, R.; Seitz, S.; Landry, R.P.; Hadden, M.L.; Painter, J.A.

    1997-01-01

    The proliferation of nuclear weapons, along with the technical knowledge and materials needed to make these weapons, is an enduring problem of international urgency. Current international nuclear nonproliferation efforts are aimed at deterring, detecting, and responding to proliferation of weapons of mass destruction. These safeguards efforts are being implemented by applying preeminent science and technology to the management and control of nuclear materials. By strengthening systems of nuclear material protection, control, and accountability (MPC and A), one can reduce the threat of nuclear weapons proliferation. Two major programs of international cooperation are now underway to achieve this goal. The first is between the US Department of Energy (DOE) and the Institutes of the Russian Federation (Laboratory-to-Laboratory Program), and the second is between the US Government and Governments of the former Soviet Republics (Government-to-Government Program). As part of these programs, the DOE is working with facilities to assist them in implementing computerized MPC and A systems. This work is a collaboration between computer scientists and safeguards experts in both the US and the new Republics. The US is making available technology and expertise to enable Russian experts to build on computerized MPC and A software developed in the US. This paper describes the joint efforts of these international teams to develop sophisticated computerized MPC and A systems using modern computer hardware and software technology. These systems are being customized to meet the site-specific needs of each facility

  14. Computerized analysis of brain perfusion parameter images

    International Nuclear Information System (INIS)

    Turowski, B.; Haenggi, D.; Wittsack, H.J.; Beck, A.; Aurich, V.

    2007-01-01

    Purpose: The development of a computerized method which allows a direct quantitative comparison of perfusion parameters. The display should allow a clear direct comparison of brain perfusion parameters in different vascular territories and over the course of time. The analysis is intended to be the basis for further evaluation of cerebral vasospasm after subarachnoid hemorrhage (SAH). The method should permit early diagnosis of cerebral vasospasm. Materials and Methods: The Angiotux 2D-ECCET software was developed with a close cooperation between computer scientists and clinicians. Starting from parameter images of brain perfusion, the cortex was marked, segmented and assigned to definite vascular territories. The underlying values were averages for each segment and were displayed in a graph. If a follow-up was available, the mean values of the perfusion parameters were displayed in relation to time. The method was developed under consideration of CT perfusion values but is applicable for other methods of perfusion imaging. Results: Computerized analysis of brain perfusion parameter images allows an immediate comparison of these parameters and follow-up of mean values in a clear and concise manner. Values are related to definite vascular territories. The tabular output facilitates further statistic evaluations. The computerized analysis is precisely reproducible, i. e., repetitions result in exactly the same output. (orig.)

  15. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Quoidbach, G.

    2004-01-01

    The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant or of any other complex industrial facility (chemical industries, refineries, and so on) in planning, organizing, and carrying out any (preventive or corrective) maintenance task. This 'Computerized Management of Plant Intervention Tasks' is organized around a data base of all plant components in the facility that might be subjected to maintenance or tagout. It allows to manage, by means of intelligent and configurable 'mail service', the course of the intervention requests as well as various treatments of those requests, in a safe and efficient way, adapted to each particular organization. The concept of 'Computerized Management' of plant intervention tasks was developed by BELGATOM in 1983 for the Belgian nuclear power plants of ELECTRABEL. A first implementation of this concept was made at that time for the Doel NPP under the name POPIT (Programming Of Plant Intervention Tasks). In 1988, it was decided to proceed to a functional upgrade of the application, using advanced software and hardware techniques and products, and to realize a second implementation in the Tihange NPP under the name ACM (Application Consignation Maintenance). (author)

  16. Diversity in computerized reactor protection systems

    International Nuclear Information System (INIS)

    Fischer, H.D.; Piel, L.

    1999-01-01

    Based on engineering judgement, the most important measures to increase the independency of redundant trains of a computerized safety instrumentation and control system (I and C) in a nuclear power plant are evaluated with respect to practical applications. This paper will contribute to an objective discussion on the necessary and justifiable arrangement of diversity in a computerized safety I and C system. Important conclusions are: - (i) diverse equipment may be used to control dependent failures only if measures necessary for designing, licensing, and operating a computerized safety I and C system homogeneous in equipment are neither technically nor economically feasible; - (ii) the considerable large operating experience in France with a non-diverse equipment digital reactor protection system does not call for equipment diversity. Although there are no generally accepted methods, the licensing authority is still required to take into account dependent failures in a probabilistic safety analysis; - (ii) the frequency of postulated initiating events implies which I and C functionality should be implemented on diverse equipment. Using non-safety I and C equipment in addition to safety I and C equipment is attractive because its necessary unavailability to control an initiating event in teamwork with the safety I and C equipment is estimated to range from 0.01 to 0.1. This can be achieved by operational experience

  17. Case of neurosarcoidosis monitored by computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, T; Kimura, M; Komai, T; Yamamoto, S; Yamamura, I [Kanazawa Univ. (Japan). School of Medicine

    1979-12-01

    A 21-year-old man complaining of impaired visual acuity was admitted to the hospital. Physical examinations showed asymptomatic bilateral hilar lymphadenopathy and cardiomyopathy. Neurological findings disclosed left blindness and right temporal hemianopsia. Computerized tomography, pneumoencephalography and carotid angiography revealed a suprasellar mass. After the admission, the following symptoms deteriorated rapidly: diabetes insipidus, anterior pituitary dysfunction, visual loss of the right eye and hepatomegaly, subsequently consciousness disorder developed during a month though he was given steroids. The more deteriorated the clinical course, the larger the suprasellar mass with expanding hydrocephalus in repeated computerized tomographies. After the ventriculo-peritoneal shunt operation, consciousness improved. Diabetes insipidus also improved after Diabenese administration. On the operation, adhesive arachnoiditis over all the frontotemporal cortex and swollen purplishly red optic chiasm were exposed. Microscopically the specimen from the optic chiasm evidenced a sarcoid granuloma which composed of epitheroid cells, lymphocytes and multi-nucleated giant cells with numerous hemosiderin droplets. The specimen from the surface of the left frontal lobe showed thick fibrosis in the subarachnoid space. By steroids therapy, diabetes insipidus and hepatomegaly disappeared five months after the admission, whereas blindness never recovered. He died of developed status epilepticus eleven months after the admission. The authors reviewed neuroradiological findings of neurocarcoidosis based on pathological findings in the literature, and emphasized that computerized tomography was the most useful for diagnosis and treatment of neurosarcoidosis.

  18. Supervisory control and diagnostics system for the mirror fusion test facility: overview and status 1980

    International Nuclear Information System (INIS)

    McGoldrick, P.R.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is a complex facility requiring a highly-computerized Supervisory Control and Diagnostics System (SCDS) to monitor and provide control over ten subsystems; three of which require true process control. SCDS will provide physicists with a method of studying machine and plasma behavior by acquiring and processing up to four megabytes of plasma diagnostic information every five minutes. A high degree of availability and throughput is provided by a distributed computer system (nine 32-bit minicomputers on shared memory). Data, distributed across SCDS, is managed by a high-bandwidth Distributed Database Management System. The MFTF operators' control room consoles use color television monitors with touch sensitive screens; this is a totally new approach. The method of handling deviations to normal machine operation and how the operator should be notified and assisted in the resolution of problems has been studied and a system designed

  19. Computerized automatic tip scanning operation

    International Nuclear Information System (INIS)

    Nishikawa, K.; Fukushima, T.; Nakai, H.; Yanagisawa, A.

    1984-01-01

    In BWR nuclear power stations the Traversing Incore Probe (TIP) system is one of the most important components in reactor monitoring and control. In previous TIP systems, however, operators have suffered from the complexity of operation and long operation time required. The system presented in this paper realizes the automatic operation of the TIP system by monitoring and driving it with a process computer. This system significantly reduces the burden on customer operators and improves plant efficiency by simplifying the operating procedure, augmenting the accuracy of the measured data, and shortening operating time. The process computer is one of the PODIA (Plant Operation by Displayed Information Automation) systems. This computer transfers control signals to the TIP control panel, which in turn drives equipment by microprocessor control. The process computer contains such components as the CRT/KB unit, the printer plotter, the hard copier, and the message typers required for efficient man-machine communications. Its operation and interface properties are described

  20. Computerized aids and human factors in nuclear power plant operation

    International Nuclear Information System (INIS)

    Bastl, W.

    1988-01-01

    When guiding a complex process and associated intermeshed systems in a nuclear power plant, a primary issue consists of the call for excellent information. Technically speaking, today's centralized control rooms are at the end of a development phase which has been governed by the introduction of remote information and remote control systems. But by centralization, an information overload problem arose, and it has been solved by dividing panels according to systems, operational phases and specific tasks. In addition, the overview and relationship of systems have been visualized by mimic diagrams. It is attempted to make transparent the technical back-ground of the processes and systems to be controlled, thus to provide the necessary basis for understanding the problems of operators. Practical examples are used for the purpose. The information dilemma, the systems for high level information, automation and information, plant safety and information, and the problem of where to go from here are described. Computerized operator aids must be discussed along assistance in information and assistance in automatic control. (Kako, I.)

  1. Image-based medical expert teleconsultation in acute care of injuries. A systematic review of effects on information accuracy, diagnostic validity, clinical outcome, and user satisfaction.

    Directory of Open Access Journals (Sweden)

    Marie Hasselberg

    Full Text Available OBJECTIVE: To systematically review the literature on image-based telemedicine for medical expert consultation in acute care of injuries, considering system, user, and clinical aspects. DESIGN: Systematic review of peer-reviewed journal articles. DATA SOURCES: Searches of five databases and in eligible articles, relevant reviews, and specialized peer-reviewed journals. ELIGIBILITY CRITERIA: Studies were included that covered teleconsultation systems based on image capture and transfer with the objective of seeking medical expertise for the diagnostic and treatment of acute injury care and that presented the evaluation of one or several aspects of the system based on empirical data. Studies of systems not under routine practice or including real-time interactive video conferencing were excluded. METHOD: The procedures used in this review followed the PRISMA Statement. Predefined criteria were used for the assessment of the risk of bias. The DeLone and McLean Information System Success Model was used as a framework to synthesise the results according to system quality, user satisfaction, information quality and net benefits. All data extractions were done by at least two reviewers independently. RESULTS: Out of 331 articles, 24 were found eligible. Diagnostic validity and management outcomes were often studied; fewer studies focused on system quality and user satisfaction. Most systems were evaluated at a feasibility stage or during small-scale pilot testing. Although the results of the evaluations were generally positive, biases in the methodology of evaluation were concerning selection, performance and exclusion. Gold standards and statistical tests were not always used when assessing diagnostic validity and patient management. CONCLUSIONS: Image-based telemedicine systems for injury emergency care tend to support valid diagnosis and influence patient management. The evidence relates to a few clinical fields, and has substantial methodological

  2. Image-based medical expert teleconsultation in acute care of injuries. A systematic review of effects on information accuracy, diagnostic validity, clinical outcome, and user satisfaction.

    Science.gov (United States)

    Hasselberg, Marie; Beer, Netta; Blom, Lisa; Wallis, Lee A; Laflamme, Lucie

    2014-01-01

    To systematically review the literature on image-based telemedicine for medical expert consultation in acute care of injuries, considering system, user, and clinical aspects. Systematic review of peer-reviewed journal articles. Searches of five databases and in eligible articles, relevant reviews, and specialized peer-reviewed journals. Studies were included that covered teleconsultation systems based on image capture and transfer with the objective of seeking medical expertise for the diagnostic and treatment of acute injury care and that presented the evaluation of one or several aspects of the system based on empirical data. Studies of systems not under routine practice or including real-time interactive video conferencing were excluded. The procedures used in this review followed the PRISMA Statement. Predefined criteria were used for the assessment of the risk of bias. The DeLone and McLean Information System Success Model was used as a framework to synthesise the results according to system quality, user satisfaction, information quality and net benefits. All data extractions were done by at least two reviewers independently. Out of 331 articles, 24 were found eligible. Diagnostic validity and management outcomes were often studied; fewer studies focused on system quality and user satisfaction. Most systems were evaluated at a feasibility stage or during small-scale pilot testing. Although the results of the evaluations were generally positive, biases in the methodology of evaluation were concerning selection, performance and exclusion. Gold standards and statistical tests were not always used when assessing diagnostic validity and patient management. Image-based telemedicine systems for injury emergency care tend to support valid diagnosis and influence patient management. The evidence relates to a few clinical fields, and has substantial methodological shortcomings. As in the case of telemedicine in general, user and system quality aspects are poorly

  3. Computerized tomography using fast neutrons

    International Nuclear Information System (INIS)

    Maier-Schuler, P.

    1992-03-01

    The equipment is transportable and can be used at different neutron sources. CT-images are presented showing that it is possible to get good results by using CT with fast neutrons in non destructive testing. Small defects with high contrasts can be detected as well as larger defects with small differences in material density. Since the neutrons interact with the nuclei and not with the electron density the CT-images contain different information compared with X-ray or γ images. As neutron sources always emit γ-radiation too, this radiation can be detected simultaneously with the neutrons. Therefore one can get a γ CT-image along with the neutron image. For the examination of small samples or objects containing materials with great differences in the linear attenuation coefficients like Al and H 2 thermal neutrons have been used for CT-measurements too. A spatial resolution and a density resolution of 0.1 mm and about 5% respectively could be achieved in the CT-images with fast neutrons and 0.04 mm with thermal neutrons. (orig./HP) [de

  4. [Is the ICU staff satisfied with the computerized physician order entry? A cross-sectional survey study].

    Science.gov (United States)

    Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto

    2014-01-01

    To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, phealthcare workers were satisfied, albeit not entirely, with the computerized physician order entry. The overall users' satisfaction with computerized physician order entry was lower among physicians compared to other healthcare professionals. The factors associated with satisfaction included the belief that digitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame.

  5. DEVELOPMENT OF INFORMATION-MEASURING SYSTEM OF DIAGNOSTICS OF ONCOLOGICAL DISEASES WITH APPLICATION OF TECHNOLOGIES OF MACHINE TRAINING

    Directory of Open Access Journals (Sweden)

    Vsevolod Novikov

    2017-12-01

    Full Text Available The purpose of the work is to create an information and measurement system of cancer with the use of machine learning technology. In this work, the object of research is the information and measuring system for diagnosing cancer, and the subject of the study is the machine learning technology based on Microsoft Azure. They are based on methods of empirical level such as: calculations, measurements, comparisons. Experimental-theoretical level methods: experiment, analysis and modeling.

  6. Informational Reinforcement of Students’ Course Design Aimed at Promoting Engineers Training Quality in Technical Education

    Directory of Open Access Journals (Sweden)

    B. N. Guzanov

    2012-01-01

    Full Text Available Using the modern information technologies in educational process is regarded as one of the main directions in training the qualified specialists with systematic engineering thinking. The optimum combination of various educational technologies and computerized resources can improve teaching quality and promote students’ professional level. Taking as an example one of the basic technical disciplines of the engineering training curriculum at a technical higher school, the authors describe the computerized technology facilitating the course design. The technology in question - the «Reduktor» courseware - adapts the complex product of Autodesk –AutoCAD for educational purposes. The above program is the enhanced interface of AutoCAD, linked to the Microsoft Excel spreadsheet and the reference data library used for designing the reduction gear. The experimental research, based on the qualimetric approach and continuous diagnostic and prognostic monitoring of the key indices of knowledge acquisition, proves the effectiveness of informational reinforcement of students self-dependent work. 

  7. A computerized program to educate adults about environmental health risks

    International Nuclear Information System (INIS)

    Adams, M.; Dewey, J.; Schur, P.

    1993-01-01

    A computerized program called Environmental Risk Appraisal (ERA) has been developed to educate adults about environmental health risks and to motivate positive behavior change. A questionnaire addresses issues such as radon, environmental tobacco smoke, pesticides, lead, air and water pollution, and work-site risks. Responses are computer processed in seconds to produce an individualized computer printout containing a score, educational messages, and phone numbers to call for more information. A variety of audiences including environmental groups, worksites, women's organizations and health professionals were represented in this study of 269 participants. Many respondents indicated they were exposed to important environmental hazards and nearly 40 percent reported they had, or might have had, an environmental related illness at some time. Preliminary evaluation indicates the program is effective as an educational tool in raising awareness of environmental health risks

  8. Computerized engineering logic for procurement and dedication processes

    International Nuclear Information System (INIS)

    Tulay, M.P.

    1996-01-01

    This paper summarizes the work performed for designing the system and especially for calculating on-line expected performance and gives some significant results. In an attempt to better meet the needs of operations and maintenance organizations, many nuclear utility procurement engineering groups have simplified their procedures, developed on-line tools for performing the specification of replacement items, and developed relational databases containing part-level information necessary to automate the procurement process. Although these improvements have helped to reduce the engineering necessary to properly specify and accept/dedicate items for nuclear safety-related applications, a number of utilities have recognized that additional long-term savings can be realized by integrating a computerized logic to assist technical procurement engineering personnel

  9. The computerized OMAHA system in microsoft office excel.

    Science.gov (United States)

    Lai, Xiaobin; Wong, Frances K Y; Zhang, Peiqiang; Leung, Carenx W Y; Lee, Lai H; Wong, Jessica S Y; Lo, Yim F; Ching, Shirley S Y

    2014-01-01

    The OMAHA System was adopted as the documentation system in an interventional study. To systematically record client care and facilitate data analysis, two Office Excel files were developed. The first Excel file (File A) was designed to record problems, care procedure, and outcomes for individual clients according to the OMAHA System. It was used by the intervention nurses in the study. The second Excel file (File B) was the summary of all clients that had been automatically extracted from File A. Data in File B can be analyzed directly in Excel or imported in PASW for further analysis. Both files have four parts to record basic information and the three parts of the OMAHA System. The computerized OMAHA System simplified the documentation procedure and facilitated the management and analysis of data.

  10. Computerized planning system for nuclear power plant evaluation

    International Nuclear Information System (INIS)

    Bonczek, R.H.; Holsapple, C.W.; Whinston, A.B.

    1976-01-01

    A computerized system is described for information storage and query processing adapted to complex socio-technological issues. The system is referred to as GPLAN (Generalized Planning System) and can accommodate both qualitative (verbal) and quantitative data. The issue illustrated is the construction of a nuclear power plant, and involves interdisciplinary research and planning. The system's outstanding features are the use of the network variety of data base, the selective retrieval of any configuration of data from a particular network structure, automatic execution of any desired application program from a standard or special library of applications, user interface with a data base and applications by submitting English-like, non-procedural queries, and generality which allows tailoring to specific applications and provides a basis for integration of planning and research activities. The system is general and can be used for a wide variety of socio-technological issues which involve complex data relationships

  11. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  12. SU-E-P-01: An Informative Review On the Role of Diagnostic Medical Physicist in the Academic and Private Medical Centers

    International Nuclear Information System (INIS)

    Weir, V; Zhang, J

    2014-01-01

    Purpose: The role of physicist in the academic and private hospital environment continues to evolve and expand. This becomes more obvious with the newly revised requirements of the Joint Commission (JC) on imaging modalities and the continued updated requirements of ACR accreditation for medical physics (i.e., starting in June 2014, a physicists test will be needed before US accreditation). We provide an informative review on the role of diagnostic medical physicist and hope that our experience will expedite junior physicists in understanding their role in medical centers, and be ready to more opportunities. Methods: Based on our experience, diagnostic medical physicists in both academic and private medical centers perform several clinical functions. These include providing clinical service and physics support, ensuring that all ionizing radiation devices are tested and operated in compliance with the State and Federal laws, regulations and guidelines. We also discuss the training and education required to ensure that the radiation exposure to patients and staff is as low as reasonably achievable. We review the overlapping roles of medical and health physicist in some institutions. Results: A detailed scheme on the new requirements (effective 7/1/2014) of the JC is provided. In 2015, new standards for fluoroscopy, cone beam CT and the qualifications of staff will be phased in. A summary of new ACR requirements for different modalities is presented. Medical physicist have other duties such as sitting on CT and fluoroscopy committees for protocols design, training of non-radiologists to meet the new fluoroscopy rules, as well as helping with special therapies such as Yittrium 90 cases. Conclusion: Medical physicists in both academic and private hospitals are positioned to be more involved and prominent. Diagnostic physicists need to be more proactive to involve themselves in the day to day activities of the radiology department

  13. SU-E-P-01: An Informative Review On the Role of Diagnostic Medical Physicist in the Academic and Private Medical Centers

    Energy Technology Data Exchange (ETDEWEB)

    Weir, V [Baylor Health Care System, Dallas, TX (United States); Zhang, J [University of Kentucky, Lexington, KY (United States)

    2014-06-01

    Purpose: The role of physicist in the academic and private hospital environment continues to evolve and expand. This becomes more obvious with the newly revised requirements of the Joint Commission (JC) on imaging modalities and the continued updated requirements of ACR accreditation for medical physics (i.e., starting in June 2014, a physicists test will be needed before US accreditation). We provide an informative review on the role of diagnostic medical physicist and hope that our experience will expedite junior physicists in understanding their role in medical centers, and be ready to more opportunities. Methods: Based on our experience, diagnostic medical physicists in both academic and private medical centers perform several clinical functions. These include providing clinical service and physics support, ensuring that all ionizing radiation devices are tested and operated in compliance with the State and Federal laws, regulations and guidelines. We also discuss the training and education required to ensure that the radiation exposure to patients and staff is as low as reasonably achievable. We review the overlapping roles of medical and health physicist in some institutions. Results: A detailed scheme on the new requirements (effective 7/1/2014) of the JC is provided. In 2015, new standards for fluoroscopy, cone beam CT and the qualifications of staff will be phased in. A summary of new ACR requirements for different modalities is presented. Medical physicist have other duties such as sitting on CT and fluoroscopy committees for protocols design, training of non-radiologists to meet the new fluoroscopy rules, as well as helping with special therapies such as Yittrium 90 cases. Conclusion: Medical physicists in both academic and private hospitals are positioned to be more involved and prominent. Diagnostic physicists need to be more proactive to involve themselves in the day to day activities of the radiology department.

  14. Diffuse lung neoplasms. Correlation between high resolution computerized tomography and anatomopathology; Neoplasias pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil). Servico de Radiologia do Pavilhao Pereira Filho; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto, SP (Brazil)]. E-mail: edmarchiori@zipmail.com.br

    2002-08-01

    A short comparative evaluation study between high resolution computerized tomography and anatomopathologic findings is presented. The association of these two diagnostic techniques is discussed as a factor to enhance the accuracy of diffuse lung diseases, such as carcinomatous lymphangitis, Kaposi's Sarcoma, lymphomas, hematogenic metastases, bronchiole-alveolar carcinoma and leukemia. (MAC)

  15. Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: methods of a decision-maker-researcher partnership systematic review.

    Science.gov (United States)

    Haynes, R Brian; Wilczynski, Nancy L

    2010-02-05

    Computerized clinical decision support systems are information technology-based systems designed to improve clinical decision-making. As with any healthcare intervention with claims to improve process of care or patient outcomes, decision support systems should be rigorously evaluated before widespread dissemination into clinical practice. Engaging healthcare providers and managers in the review process may facilitate knowledge translation and uptake. The objective of this research was to form a partnership of healthcare providers, managers, and researchers to review randomized controlled trials assessing the effects of computerized decision support for six clinical application areas: primary preventive care, therapeutic drug monitoring and dosing, drug prescribing, chronic disease management, diagnostic test ordering and interpretation, and acute care management; and to identify study characteristics that predict benefit. The review was undertaken by the Health Information Research Unit, McMaster University, in partnership with Hamilton Health Sciences, the Hamilton, Niagara, Haldimand, and Brant Local Health Integration Network, and pertinent healthcare service teams. Following agreement on information needs and interests with decision-makers, our earlier systematic review was updated by searching Medline, EMBASE, EBM Review databases, and Inspec, and reviewing reference lists through 6 January 2010. Data extraction items were expanded according to input from decision-makers. Authors of primary studies were contacted to confirm data and to provide additional information. Eligible trials were organized according to clinical area of application. We included randomized controlled trials that evaluated the effect on practitioner performance or patient outcomes of patient care provided with a computerized clinical decision support system compared with patient care without such a system. Data will be summarized using descriptive summary measures, including proportions

  16. Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: Methods of a decision-maker-researcher partnership systematic review

    Directory of Open Access Journals (Sweden)

    Wilczynski Nancy L

    2010-02-01

    Full Text Available Abstract Background Computerized clinical decision support systems are information technology-based systems designed to improve clinical decision-making. As with any healthcare intervention with claims to improve process of care or patient outcomes, decision support systems should be rigorously evaluated before widespread dissemination into clinical practice. Engaging healthcare providers and managers in the review process may facilitate knowledge translation and uptake. The objective of this research was to form a partnership of healthcare providers, managers, and researchers to review randomized controlled trials assessing the effects of computerized decision support for six clinical application areas: primary preventive care, therapeutic drug monitoring and dosing, drug prescribing, chronic disease management, diagnostic test ordering and interpretation, and acute care management; and to identify study characteristics that predict benefit. Methods The review was undertaken by the Health Information Research Unit, McMaster University, in partnership with Hamilton Health Sciences, the Hamilton, Niagara, Haldimand, and Brant Local Health Integration Network, and pertinent healthcare service teams. Following agreement on information needs and interests with decision-makers, our earlier systematic review was updated by searching Medline, EMBASE, EBM Review databases, and Inspec, and reviewing reference lists through 6 January 2010. Data extraction items were expanded according to input from decision-makers. Authors of primary studies were contacted to confirm data and to provide additional information. Eligible trials were organized according to clinical area of application. We included randomized controlled trials that evaluated the effect on practitioner performance or patient outcomes of patient care provided with a computerized clinical decision support system compared with patient care without such a system. Results Data will be summarized

  17. Computerized tomography of the lumbar vertebral column after intervertebral disk operation. Pt. 1

    International Nuclear Information System (INIS)

    Schindler, G.; Klott, K.

    1984-01-01

    Problems after intervertebral disk operations are to be expected in about 25-40% of the patients operated. Progressive degnerative alterations at the disks, the vertebrae and the intervertebral joints entail chronic mechanical pain resulting from the sensitive innervation of the structures mentioned, or lead in severe cases to the alteration of the epidural space respectively the spinal nerves with corresponding peripheral neurological symptoms. As post-surgical complications spondylodiscitis, spondylitis, haematomae, liquor fistulae, and split-off bone fragments can be the cause of complaints, for which computerized tomography is a better diagnostical method than myelography. (BWU) [de

  18. Intoxication for methyl alcohol: computerized tomography and finding in the necrosis

    International Nuclear Information System (INIS)

    Abaitua Ibanez, J.M.; Garcia Monco, J.C.; Gallardo Rebollan, S.; Hernando Aguado, G.; Alcaraz, R.; Lopez-Ruiz, J.A.

    1994-01-01

    We present a case of voluntary intake of methyl alcohol studied by means of computerized tomography (CT) in a previously healthy patient. The classical findings of bilateral putaminal necrosis are corroborated and cerebral white matter lesions are detected in frontal and occipital zones, signs that are unusual in this disorder. CT can be of diagnostic interest in certain comas of metabolic origin such as methanol intoxication, revealing antemortem lesions of both putamens and white matter. Finally, a correlation between the CT and necropsy findings is established. (Author) 11 refs

  19. Emission computerized axial tomography from multiple gamma-camera views using frequency filtering.

    Science.gov (United States)

    Pelletier, J L; Milan, C; Touzery, C; Coitoux, P; Gailliard, P; Budinger, T F

    1980-01-01

    Emission computerized axial tomography is achievable in any nuclear medicine department from multiple gamma camera views. Data are collected by rotating the patient in front of the camera. A simple fast algorithm is implemented, known as the convolution technique: first the projection data are Fourier transformed and then an original filter designed for optimizing resolution and noise suppression is applied; finally the inverse transform of the latter operation is back-projected. This program, which can also take into account the attenuation for single photon events, was executed with good results on phantoms and patients. We think that it can be easily implemented for specific diagnostic problems.

  20. Tree-structured vector quantization of CT chest scans: Image quality and diagnostic accuracy

    International Nuclear Information System (INIS)

    Cosman, P.C.; Tseng, C.; Gray, R.M.; Olshen, R.A.; Moses, L.E.; Davidson, H.C.; Bergin, C.J.; Riskin, E.A.

    1993-01-01

    The quality of lossy compressed images is often characterized by signal-to-noise ratios, informal tests of subjective quality, or receiver operating characteristic (ROC) curves that include subjective appraisals of the value of an image for a particular application. The authors believe that for medical applications, lossy compressed images should be judged by a more natural and fundamental aspect of relative image quality: their use in making accurate diagnoses. They apply a lossy compression algorithm to medical images, and quantify the quality of the images by the diagnostic performance of radiologists, as well as by traditional signal-to-noise ratios and subjective ratings. The study is unlike previous studies of the effects of lossy compression in that they consider non-binary detection tasks, simulate actual diagnostic practice instead of using paired tests or confidence rankings, use statistical methods that are more appropriate for non-binary clinical data than are the popular ROC curves, and use low-complexity predictive tree-structured vector quantization for compression rather than DCT-based transform codes combined with entropy coding. Their diagnostic tasks are the identification of nodules (tumors) in the lungs and lymphadenopathy in the mediastinum from computerized tomography (CT) chest scans. For the image modality, compression algorithm, and diagnostic tasks they consider, the original 12 bit per pixel (bpp) CT image can be compressed to between 1 bpp and 2 bpp with no significant changes in diagnostic accuracy

  1. Ultrasonic and computerized tomographic semiotics of cholelithiasis

    International Nuclear Information System (INIS)

    Kishkovskij, A.N.; Kuznetsov, S.V.; Fadeev, V.D.

    1986-01-01

    Altogether 447 patients with suspected cholelithiasis were examined by means of routine X-ray methods, ultrasound (US) and computerized tomography (CT).Of them in 104 (23.3%) chole- and/or choledocholithiasis were later confirmed. An US and CT-picture of the biliferous tracts in health were described.In cholelithiasis during US examination echogenic concrements producing a stable acoustic shadow were defined in the gall bladder cavity and/or in the biliferous ducts. A study was made of the features of the US picture with relation to size, quantity, echodensity and grouping of concrements in the biliferous ducts. CT-symptomatology of cholelithiasis was described

  2. Computerized tomography in radiodiagnosis of pneumonia

    International Nuclear Information System (INIS)

    Degtyareva, I.A.; Mamaev, V.V.; Savchenko, A.P.

    1989-01-01

    Experience in the use of computerized tomography (CT) in combined radiodiagnosis of pneumonia was analysed. It has been concluded that CT objectively reflects morphological inflammatory changes and permits their all-round assessment over time. The diagnosis of pneumonia in CT is based on classical x-ray symptoms. As compared to survery radiography CT reveals symptoms of pneumonia to the full at earlier stages. CT is an important additional method of investigation of inflammatory pulmonary diseases but it should not be used separately without survey radiography. In a majority of cases when CT is performed there is no need in x-ray tomography

  3. Visualization in the age of computerization

    CERN Document Server

    Carusi, Annamaria; Webmoor, Timothy; Woolgar, Steve

    2014-01-01

    Digitalization and computerization are now pervasive in science. This has deep consequences for our understanding of scientific knowledge and of the scientific process, and challenges longstanding assumptions and traditional frameworks of thinking of scientific knowledge. Digital media and computational processes challenge our conception of the way in which perception and cognition work in science, of the objectivity of science, and the nature of scientific objects. They bring about new relationships between science, art and other visual media, and new ways of practicing science and organizing

  4. Development of a computerized tomographic system

    International Nuclear Information System (INIS)

    Borges, J.C.; Santos, C.A.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory at COPPE/UFRJ has been developing techniques for detection and applications of nuclear radiations. A lot of research work has been done and resulted in several M.Sc. and D.Sc. thesis, concerning subjects like neutrongraphy, gammagraphy, image reconstruction, special detectors, etc. Recent progress and multiple applications of the computerized tomography to medical and industrial non-destructive tests, pushed the Laboratory to a vast program in this field of research. In this paper, we report what has been done and the results obtained. (Author) [pt

  5. Computerized tomography in diagnosis of cerebrocranial injury

    International Nuclear Information System (INIS)

    Kornienko, V.N.; Vasin, N.Ya.; Kuz'menko, V.A.

    1987-01-01

    The method of computerized tomographical examination are presented. Th KT-characters of concussion of the brain, its contusion of different severity, compressions in case of traumatic intracranial hematomas, contusion injuries, brain edema and different aftereffects of cerebrocranial injury are given. On the basis of comparison of the data of clinical and KT examination the dynamics of intracranial traumatic injuries in the course of treatment is described. The problems of therapeutic and surgical tactics depending on the degree and form of intracranial structure injuries and the phase of clinical course of posttraumatic process are discussed

  6. Computerized abdominal tomography in Wilson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchikura, Keiko; Ogawa, Teruyuki; Nakajima, Akihisa; Ono, Yasuhiko

    1986-05-01

    Cranial and abdominal computerized tomography (CT) was performed in a 10-year-old boy with Wilson's disease complicated by liver cirrhosis. Abdominal CT showed diffuse high density areas over the whole part of the liver propably due to copper sediments, although there was no abnormal cranial CT findings. Decreased high density area of the liver was seen 60 days after the administration of D-penicillamine, suggesting the excretion of copper from the liver. Abdominal CT, as well as cranial CT, may be of help to diagnose Wilson's disease and evaluate therapeutic effects. (Namekawa, K.).

  7. Assessment of computerized tomography devices in Minas Gerais state, Brazil

    International Nuclear Information System (INIS)

    Oliveira, Paulo Marcio C.; Horta, Mara Alice Avelar Saraiva; Santana, Priscila do Carmo; Magalhaes, Marcos Juliano

    2011-01-01

    Computed Tomography (CT) is the diagnostic imaging method most commonly performed today. It is a device that is undergoing a technological evolution and their quality control is sorely needed. The image quality evaluation process allow a better diagnosis and control of the patient dose received during image acquisition. The CT doses are higher than other X-ray examination techniques, like a conventional X-ray. Performance evaluation of computed tomography in Minas Gerais is not significant. Therefore, this work aims to analyze 20 CT equipment in Minas Gerais, with parameters according to the national regulatory agency (ANVISA - Agencia Nacional de Vigilancia Sanitaria) in twelve quality control tests. Sixty five percent (65%) of CT equipment evaluated showed excellent results and were not disapproved in any of the tests performed and 30% had failed in only one of the twelve tests performed. The worst result was found in the CT scanners in the test that evaluates the low contrast resolution, where 20% of CT showed non-compliance, followed by the test that evaluates the x-rays collimation beam, where 15% had failed. The tests allowed us to observe that the twenty computerized tomography equipment achieved a great pass rate. Considering that the evaluated CTs performed the quality control tests for the first time, it is concluded that the equipment used in clinics and hospitals are of good quality image and low radiation doses. (author)

  8. Influence of step complexity and presentation style on step performance of computerized emergency operating procedures

    Energy Technology Data Exchange (ETDEWEB)

    Xu Song [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Li Zhizhong [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)], E-mail: zzli@tsinghua.edu.cn; Song Fei; Luo Wei; Zhao Qianyi; Salvendy, Gavriel [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)

    2009-02-15

    With the development of information technology, computerized emergency operating procedures (EOPs) are taking the place of paper-based ones. However, ergonomics issues of computerized EOPs have not been studied adequately since the industrial practice is quite limited yet. This study examined the influence of step complexity and presentation style of EOPs on step performance. A simulated computerized EOP system was developed in two presentation styles: Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination. Step complexity was quantified by a complexity measure model based on an entropy concept. Forty subjects participated in the experiment of EOP execution using the simulated system. The results of data analysis on the experiment data indicate that step complexity and presentation style could significantly influence step performance (both step error rate and operation time). Regression models were also developed. The regression analysis results imply that operation time of a step could be well predicted by step complexity while step error rate could only partly predicted by it. The result of a questionnaire investigation implies that step error rate was influenced not only by the operation task itself but also by other human factors. These findings may be useful for the design and assessment of computerized EOPs.

  9. Prostate carcinoma: current diagnostic strategy

    International Nuclear Information System (INIS)

    Schwarzschild, Monica Maria Agata Stiepcich; Ferraz, Maria Lucia Cardoso Gomes; Oliveira, Jose Marcelo Amatuzzi; Andriolo, Adagmar

    2001-01-01

    Prostate cancer is the second cause of cancer death in men in the Western world. Despite progress in the treatment of advanced disease, it is recognized that the only possibility of reduction in prostate cancer death is nearly diagnosis when the disease is localized. In the present study our aim was to review the current strategy for diagnosis of prostate carcinoma. Prostate-specific antigen (PSA) is a valuable tumor marker and has demonstrated effectiveness in detecting prostate carcinoma, monitoring therapeutic efficacy, and disclosing disease recurrence. However, alternative methods are been proposed just as the free to total PSA ratio, PSA density, PSA velocity, which could improve the diagnostic sensibility and the specificity. Image diagnostic methods include transrectal ultra sound, computerized tomography, magnetic resonance image, and bone cintigraphy. The ultra sound is the best approach to guide the prostate biopsy and, together with the magnetic resonance is still useful for loco regional graduation. Computerized tomography as magnetic resonance image can be used for identification of linfonodal involvement. Bone cintigraphy is the best method for the identification of metastatic disease. (author)

  10. Constructive alignment of a research-informed teaching activity within an undergraduate diagnostic radiography curriculum: A reflection.

    Science.gov (United States)

    Higgins, R; Hogg, P; Robinson, L

    2017-09-01

    To evaluate the learning experience of a level 5 (year 2) student cohort within a research-informed teaching (RiT) activity and to map findings against learning outcomes and level descriptors using constructive alignment. An online questionnaire was used to explore the level 5 student experience of a Research-informed Teaching (RiT) activity. Responses were retrospectively mapped against Framework for Higher Education Qualifications (FHEQ) level descriptors for level 5 using constructive alignment. Thirty one out of 46 level 5 students completed the questionnaire (67% response rate). Analysis of the questionnaire supported the integration of this RiT activity within the curriculum in terms of learning and research skill development by students. However, it was identified that this activity could be revised further to better align with level 5 descriptors and incorporate additional higher level cognitive processes. Learning outcomes for this RiT activity were constructively aligned with FHEQ level 5 descriptors. Recommendations are provided on how these could be further refined to ensure students undertake a more critical approach to the application of theory into practice. Discussion also considers how this process could be used to develop a similar RiT activity at level 6 (year 3). Copyright © 2016 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  11. TFTR diagnostic control and data acquisition system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-01-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development

  12. Diagnostics of the Enterprise Economic Security and the Role of Information and Communication in the Context of Sustainability of Dynamical Equilibrium, Operation and Development

    Directory of Open Access Journals (Sweden)

    Skrynkovskyy Ruslan M.

    2015-03-01

    Full Text Available In the scientific article a system for diagnostics of the enterprise economic security is developed. It has been determined that the main business indicators for diagnostics of the enterprise economic security are: the level of the enterprise financial stability (contains the indicator for the enterprise provision with its own funds, rate of independence, financial stability indicator, current assets to equity ratio, liquid ratio, absolute liquidity ratio, current liquidity ratio; level of the enterprise production activity (calculated on the output-capital ratio, capital-labor ratio, index of workforce productivity, quality indicators of fixed assets, production potential indicator, production profitability ratio, input-output coefficient; level of organizational and administrative activities of the enterprise (takes into account the ratio of administrative expenses to the rate of increase in production volume, rate of saving of the managerial apparatus, rate of information processing; level of employee loyalty to the enterprise (calculated on the rate of personnel turnover, rate of personnel continuity, indicator of employee satisfaction, personnel development indicator, education level of employees; level of scientific and technical and innovative activity of the enterprise (including index of profitability of innovations, profitability of expenditures on research and development works; level of investment activity of the enterprise (includes index of investment profitability, rate of investment activity, rate of return on investments, rate of investment in production; level of market reliability (calculated on index of return on sales, index of return on net assets, index of marketability, level of market research. It has been identified that an important role in the context of sustainability of dynamical equilibrium, operation and development of enterprises is played by information and communication.

  13. Computerized tomographic in non-destructive testing

    International Nuclear Information System (INIS)

    Lopes, R.T.

    1988-01-01

    The process of computerized tomography has been developed for medical imaging purposes using tomographs with X-ray, and little attention has been given to others possibles applications of technique, because of its cost. As an alternative for the problem, we constructed a Tomographic System (STAC-1), using gamma-rays, for nonmedical applications. In this work we summarize the basic theory of reconstructing images using computerized tomography and we describe the considerations leading to the development of the experimental system. The method of reconstruction image implanted in the system is the filtered backprojection or convolution, with a digital filters system to carried on a pre-filtering in the projections. The experimental system is described, with details of control and the data processing. An alternative and a complementary system, using film as a detector is shown in preliminary form . This thesis discuss and shows the theorical and practical aspects, considered in the construction of the STAC-1, and also its limitations and apllications [pt

  14. Staging of pharyngeal cancer by computerized tomography during phonation. Comparison of CT findings with endoscopy and pharyngography

    International Nuclear Information System (INIS)

    Warmuth-Metz, M.; Feyerabend, T.; Schmitt, R.; Richter, E.

    1989-01-01

    46 patients with histologically proven carcinoma of the oro- and/or hypopharynx underwent clinical and endoscopic examination as well as double-contrast-pharyngography and computerized tomography (CT). The results of the different diagnostic procedures according to the TNM-classification (UICC) were compared with each other. Additional information by CT was obtained in 40% of cases. In 30%, the TNM-classification had to be changed up to one or even up to two T-categories. Major improvement of the CT-evaluation of carcinoma of the pharynx can be achieved by the additional use of CT during phonation: in our study 50% of pharyngeal cancers were thus better delimited in their extent and relations to the surrounding anatomical structures. Especially for the evaluation of the base of the tongue, the hypopharynx and the epiglottis CT during phonation (similar to the use of the double-contrast technique in pharyngography) is superior to CT at rest because the anatomy of the pharynx and therefore the extent of a mass is much better demonstrated. (orig.) [de

  15. The system for diagnostics and monitoring of the IBR-2 reactor state. Data acquisition, accumulation and storage of information

    International Nuclear Information System (INIS)

    Ermilov, V.G.; Ivanov, V.V.; Korolev, V.S.; Pepelyshev, Yu.N.; Semashko, S.V.; Tulaev, A.B.

    2000-01-01

    The architectural decisions for a developed distributed system of the IBR-2 pulsed reactor conditions monitoring are described. The system is intended for measurement of the basic reactor parameters, acquisition, storage and processing of information, the current reactor state monitoring, analysis of reactor parameters for a long time operation period both in on-line, and in off-line modes. The system is constructed in the architecture client-server using DBMS MS SQL Server 7.0 The basic hardware components of the system are measuring workstations and devices, processing and user workstations and the central server. The software of the system consists of the measuring programs, data flows dispatching services, client applications for data processing and visualization, and means for preparing data for subsequent presentation in WWW. The basic results of the first system operation phase and prospect of its development are discussed. (author)

  16. Constructive alignment of a research-informed teaching activity within an undergraduate diagnostic radiography curriculum: A reflection

    International Nuclear Information System (INIS)

    Higgins, R.; Hogg, P.; Robinson, L.

    2017-01-01

    Aim: To evaluate the learning experience of a level 5 (year 2) student cohort within a research-informed teaching (RiT) activity and to map findings against learning outcomes and level descriptors using constructive alignment. Method: An online questionnaire was used to explore the level 5 student experience of a Research-informed Teaching (RiT) activity. Responses were retrospectively mapped against Framework for Higher Education Qualifications (FHEQ) level descriptors for level 5 using constructive alignment. Results and Discussion: Thirty one out of 46 level 5 students completed the questionnaire (67% response rate). Analysis of the questionnaire supported the integration of this RiT activity within the curriculum in terms of learning and research skill development by students. However, it was identified that this activity could be revised further to better align with level 5 descriptors and incorporate additional higher level cognitive processes. Conclusion: Learning outcomes for this RiT activity were constructively aligned with FHEQ level 5 descriptors. Recommendations are provided on how these could be further refined to ensure students undertake a more critical approach to the application of theory into practice. Discussion also considers how this process could be used to develop a similar RiT activity at level 6 (year 3). - Highlights: • Constructive alignment helped to ensure that the learning outcomes were appropriately aligned with level 5 descriptors. • Reflection identified outcomes that required further improvement to focus on higher-order thinking and application skills. • This article also illustrates how this process could be used to develop a level 6 RiT activity.

  17. Enhancing the functionality of reactor protection systems to provide diagnostic and monitoring information: The ISAT{sup TM} approach

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, J A; Rowe, B J [AEA Technology, Winfrith (United Kingdom); Jones, C D [Nuclear Electric Ltd., Kent (United Kingdom). Dungeness ` B` Power Station

    1997-12-31

    The ISAT{sup TM} architecture has been successfully implemented as the Single Channel Trip System (SCTS), part of the primary protection system of Nuclear Electric`s Dungeness `B` Advanced Gas-Cooled Reactors. The system is the first computer-based protection system licensed on a UK civil nuclear reactor. The system provides protection against single channel faults resulting in high coolant gas outlet temperature. The SCTS was designed to output data at several points in the system to an Ethernet to allow checks to be made on the operation of parts of the protection system and the system as a whole. In order to monitor the performance of this shutdown system a PC based monitoring system was developed to take input as data from the Ethernet, check its integrity and then analyze the data to provide information of the state of the system and subsystems. The SCTS monitor was basically intended to alert the operator to any fault on the safety system and indicate its source, provide a diagnosis of the cause of any trip initiated by the safety system, and log the occurrences of these incidents for later inspection. The intention was also to provide accurate real-time information on the thermocouple readings and to decrease the effort required to maintain the safety system. This paper will describe briefly the development of the ISAT{sup TM} monitoring system: how its requirements were arrived at, and how the design, code and testing were carried out to ensure approval for this application. It will then go on to report how the ISAT{sup TM} monitor has performed during its time in service: how more functionality has been added over and above its original requirements. Features of additional monitors for the SCTS and other ISAT{sup TM} systems will also be described. (author). 2 refs, 5 figs.

  18. Radiation conditions for computerized tomography: determination and comparison

    International Nuclear Information System (INIS)

    Andrade, Lucio das Chagas de

    2016-01-01

    Radiology is the practice in which radiation beams, usually radiation X are used to produce an image of the human body in order to obtain a diagnosis, for example, to evaluate a pathological condition by computerized tomography (CT). Although the computerized tomography diagnostic potential is unquestionable, caution must be taken because the doses are almost always higher than the observed in conventional radiology procedures. The ionization chamber used for dosimetry in CT is a unsealed cylindrical chamber with 10 cm and 15 cm of sensitive length. A typical characteristics of this camera is its uniform response to radiation incident at all angles around its axis. The revised edition of IEC 61267 (2005) brought as an innovation the radiation conditions for computed tomography, RQT, that simulate non-attenuated beam and are used in special CT applications. This study aims to establish the necessary conditions to obtain radiation pattern beam computed tomography, RQT, and a calibration laboratory implementation for pencil ionization chambers used in the beam dosimetry produced by these scanners in the Metrology National Laboratory of Ionizing Radiation (LNMRI). In the implementation of RQT conditions we were found that the ratio of kerma rates in the air, with or without additional filtration equivalent to the first HVL (half-value layer), are in accordance with IEC 61267 (2005), which provides a range between 48.5% and 51.5% for each quality. The LNMRI characterized the radiation conditions of RQT series (IEC, 2005), obtaining a percentage of 49.6% for the RQT 8, 50% for the RQT 9 and 50,4% for the RQT 10. With the substitution of the total additional filtration RQT qualities, composed by Al + Cu and by a total filtration composed by copper (Cu) only, it can be seen the emergence of a similar RQT quality named Quality Copper Tomography - QCT. The results of the calibration, the RQT and QCT qualities, had expanded uncertainties with a confidence level 95.45%, less

  19. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  20. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  1. Computerized tomography in evaluation of the pulmonary hilum

    International Nuclear Information System (INIS)

    Secaf, M.; Ferreira, J.L.N.; Secaf, E.

    1987-01-01

    The use of computerized tomography as a method for evaluating the pulmonary hilum and its application in the diagnosis of endobronchial lesions, hilar masss, contiguous involvement of the mediastinum by hilar mass, and vascular hilar lesions are discussed. A comparative evaluation between conventional tomograms and computerized tomography is presented. (M.A.C.) [pt

  2. Legal Issues for an Integrated Information Center.

    Science.gov (United States)

    Rees, Warren; And Others

    1991-01-01

    The ability to collect, store, retrieve, and combine information in computerized databases has magnified the potential for misuse of information. Laws have begun to deal with these new threats by expanding rights of privacy, copyright, misrepresentation, products liability, and defamation. Laws regarding computerized databases are certain to…

  3. Age influence on attitudes of office workers faced with new computerized technologies: a questionnaire analysis.

    Science.gov (United States)

    Marquié, J C; Thon, B; Baracat, B

    1994-06-01

    expected, the study revealed that one third of the users never received any specific training, and that many of those who benefited from it were trained for only a few days. Consultation of the staff during the computerization process also appeared to be poor, to apply mostly to the best trained and qualified workers, and to be more highly developed in small companies. The results are discussed in the light of more qualitative data recorded during the survey. They suggest the need to increase information, training and involvement of all personnel from the very first stages of computerization (or other technical changes) in order to lessen fears and the feeling of disruption, which are particularly obvious among the oldest workers.

  4. Sequential computerized tomography changes and related final outcome in severe head injury patients

    International Nuclear Information System (INIS)

    Lobato, R.D.; Gomez, P.A.; Alday, R.

    1997-01-01

    The authors analyzed the serial computerized tomography (CT) findings in a large series of severely head injured patients in order to assess the variability in gross intracranial pathology through the acute posttraumatic period and determine the most common patterns of CT change. A second aim was to compare the prognostic significance of the different CT diagnostic categories used in the study (Traumatic Coma Data Bank CT pathological classification) when gleaned either from the initial (postadmission) or the control CT scans, and determine the extent to which having a second CT scan provides more prognostic information than only one scan. 92 patients (13.3 % of the total population) died soon after injury. Of the 587 who survived long enough to have at least one control CT scan 23.6 % developed new diffuse brain swelling, and 20.9 % new focal mass lesions most of which had to be evacuated. The relative risk for requiring a delayed operation as related to the diagnostic category established by using the initial CT scans was by decreasing order: diffuse injury IV (30.7 %), diffuse injury III (30.5 %), non evacuated mass (20 %), evacuated mass (20.2 %), diffuse injury II (12.1 %), and diffuse injury I (8.6 %). Overall, 51.2 % of the patients developed significant CT changes (for worse or better) occurring either spontaneously or following surgery, and their final outcomes were more closely related to the control than to the initial CT diagnoses. In fact, the final outcome was more accurately predicted by using the control CT scans (81.2 % of the cases) than by using the initial CT scans (71.5 % of the cases only). Since the majority of relevant CT changes developed within 48 hours after injury a pathological categorization made by using an early control CT scan seems to be most useful for prognostic purposes. Prognosis associated with the CT pathological categories used in the study was similar independently of the moment of the acute posttraumatic period at which

  5. Energy for agriculture: a computerized information retrieval system

    Energy Technology Data Exchange (ETDEWEB)

    Stout, B A; Myers, C A [comp.

    1979-12-01

    This bibliography contains 2613 citations to the literature for 1973 through May 1979. Some of the subjects covered include: accounting, agriculture, animal production, conservation, drying, fertilizer, food processing, greenhouses, home, international, irrigation, organic, solar, storage, tillage, and wind. Author and keyword indexes are included. (MHR)

  6. The evolution of the market for commercial computerized physician order entry and computerized decision support systems for prescribing.

    Science.gov (United States)

    Mozaffar, Hajar; Williams, Robin; Cresswell, Kathrin; Morrison, Zoe; Bates, David W; Sheikh, Aziz

    2016-03-01

    To understand the evolving market of commercial off-the-shelf Computerized Physician Order Entry (CPOE) and Computerized Decision Support (CDS) applications and its effects on their uptake and implementation in English hospitals. Although CPOE and CDS vendors have been quick to enter the English market, uptake has been slow and uneven. To investigate this, the authors undertook qualitative ethnography of vendors and adopters of hospital CPOE/CDS systems in England. The authors collected data from semi-structured interviews with 11 individuals from 4 vendors, including the 2 most entrenched suppliers, and 6 adopter hospitals, and 21 h of ethnographic observation of 2 user groups, and 1 vendor event. The research and analysis was informed by insights from studies of the evolution of technology fields and the emergence of generic COTS enterprise solutions. Four key themes emerged: (1) adoption of systems that had been developed outside of England, (2) vendors' configuration and customization strategies, (3) localized adopter practices vs generic systems, and (4) unrealistic adopter demands. Evidence for our over-arching finding concerning the current immaturity of the market was derived from vendors' strategies, adopters' reactions to the technology, and policy makers' incomplete insights. The CPOE/CDS market in England is still in an emergent phase. The rapid entrance of diverse products, triggered by federal policy initiatives, has resulted in premature adoption of systems that do not yet adequately meet the needs of hospitals. Vendors and adopters lacked understanding of how to design and implement generic solutions to meet diverse user needs. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Adjustment of the Kompleks Titan-2 monitoring computerized system at the Rovno NPP third unit

    International Nuclear Information System (INIS)

    Zigaev, B.P.

    1987-01-01

    Information signal origin and processing processes in the monitoring computerized system 'Komplex Titan-2' at the Rovno NPP third unit are considered. The system exercises control over the following production equipment parameters: the state of keys of control of lock fittings, mechanisms, regulators, reserve mechanism automatic shut-down circuit; the state of lock fittings, mechanisms, regulators, reserve mechanism automated switching on; parameter deviation from permissible values; interlock operation; protection system state; the state of autonomous units and devices

  8. simulate_CAT: A Computer Program for Post-Hoc Simulation for Computerized Adaptive Testing

    Directory of Open Access Journals (Sweden)

    İlker Kalender

    2015-06-01

    Full Text Available This paper presents a computer software developed by the author. The software conducts post-hoc simulations for computerized adaptive testing based on real responses of examinees to paper and pencil tests under different parameters that can be defined by user. In this paper, short information is given about post-hoc simulations. After that, the working principle of the software is provided and a sample simulation with required input files is shown. And last, output files are described

  9. Proposal for dose measurement in the crystalline lens and thyroid in computerized tomography of paranasal sinuses

    International Nuclear Information System (INIS)

    Mello, Ana Caroline; Machado Neto, Vicente

    2014-01-01

    With the evolution of diagnostic imaging equipment, a computerized tomography (CT) has become one of the most used tests to assess pathologies affecting the paranasal sinuses. This work aims at presenting a method of obtaining measurements of dose in the eye lenses and thyroid, from the execution of CT of the paranasal sinuses protocol. Experimental procedure will be used in an object simulator (phantom) head and neck made with accessible materials and thermoluminescent dosimeters (TLDs) of LiF: Mg,Ti for the absorbed dose in the regions of interest, when exposed to radiation in a CT scanner 16 channels. After the dosimetric evaluation with phantom use, this methodology will be applied in vivo, or in patients with medical request for the examination and approval by the Ethics Committee. Thus, at the end of this survey protocols and actions aimed at reducing the absorbed dose in the eye lenses and thyroid without impairing the diagnostic image quality can be proposed. (author)

  10. [Differentiation Study of Chinese Medical Syndrome Typing for Diarrhea-predominant Irritable Bowel Syndrome Based on Information of Four Chinese Medical Diagnostic Methods and Brain-gut Peptides].

    Science.gov (United States)

    Wu, Hao-meng; Xu, Zhi-wei; Ao, Hai-qing; Shi, Ya-fei; Hu, Hai-yan; Ji, Yun-peng

    2015-10-01

    To establish discriminant functions of diarrhea-predominant irritable bowel syndrome (IBS-D) by studying it from quantitative diagnosis angle, hoping to reduce interference of subjective factors in diagnosing and differentially diagnosing Chinese medical syndromes of IBS-D. A Chinese medical clinical epidemiological survey was carried out in 439 IBS-D patients using Clinical Information Collection Table of IBS. Initial syndromes were obtained by cluster analysis. They were analyzed using step-by-step discrimination by taking information of four Chinese medical diagnostic methods and serum brain-gut peptides (BGP) as variables. Clustering results were Gan stagnation Pi deficiency syndrome (GSPDS), Pi-Wei weakness syndrome (PWWS), Gan stagnation qi stasis syndrome (GSQSS), Pi-Shen yang deficiency syndrome (PSYDS), Pi-Wei damp-heat syndrome (PWDHS), cold-damp disturbing Pi syndrome (CDDPS). Of them, GSPDS was mostly often seen with effective percentage of 34. 2%, while CDDPS was the least often seen with effective percentage of 5.5%. A total of 5 discriminant functions for GSPDS, PWWS, GSQSS, PSYDS, and PWDHS were obtained by step-by-step dis- crimination method. The retrospective misjudgment rate was 4.1% (16/390), while the cross-validation misjudgment rate was 15.4% (60/390). The establishment of discriminant functions is of value in objectively diagnosing and differentially diagnosing Chinese medical syndromes of IBS-D.

  11. The water reactor safety research project index: a description of the computerized system for its databank

    International Nuclear Information System (INIS)

    Della Loggia, E.; Primavera, R.

    1993-01-01

    The water reactor nuclear safety research project index has been published by the CEC for many years as a compilation of information on research projects relating to LWR nuclear safety. Since 1981, it has been published, alternatively with NEA (OECD), every second year. The number of contributions from research organizations in Community member countries has steadily increased and reached the level of 1 700 pages, in which more than 600 project descriptions have been collected. In 1988, for the first time, the document was produced using a computerized system developed with the assistance of the ISEI (Institute for Systems Engineering and Informatics) of JRC Ispra. The data have been stored in a computer based in Ispra. The system allows searching a preselected set of subjects through the information stored in the computer: it makes the updating of the projects description much easier and makes the retrieval of the data possible. This report presents a short description of the computerized system developed for the databank of the index. The computerized system presented in this report is structured in a quite general way and for that reason can be adapted very easily to every field where a databank needs to be constituted in order to collect extended information on several projects. (authors). 6 figs., 5 tabs., 5 refs

  12. Computerized accountability program is operating - DYMCAS

    International Nuclear Information System (INIS)

    Combs, S.W.; Mee, W.T.

    1983-01-01

    The nuclear materials control and accountability program in the Oak Ridge Y-12 Plant has been placed on a computerized system identified as DYMCAS (Dynamic Special Nuclear Materials Control and Accountability System). The primary gola of the DYMCAS is to assist in detecting the diversion of special nuclear material (SNM). Secondly, the system is expected to assure quality inventory reconciliations both under normal and emergency situations. The system has been installed and was placed on active status in April 1982. Since that time numerous problems have surfaced and been resolved; i.e., delays of input, hardware breakdown, and misunderstandings of needs. An explanation of these problems, including examples and alterations that have made the system workable, are presented

  13. A computerized accountability program is operating - DYMCAS

    International Nuclear Information System (INIS)

    Combs, S.W.; Mee, W.T.

    1983-01-01

    The nuclear materials control and accountability program in the Oak Ridge Y-12 Plant has been placed on a computerized system identified as DYMCAS (Dynamic Special Nuclear Materials Control and Accountability System). The primary goal of the DYMCAS is to assist in detecting the diversion of special nuclear material (SNM). Secondly, the system is expected to assure quality inventory reconciliations both under normal and emergency situations. The system has been installed and was placed on active status in April 1982. Since that time numerous problems have surfaced and been resolved; i.e., delays of input, hardware breakdown, and misunderstandings of needs. An explanation of these problems, including examples and alterations that have made the system workable, are presented

  14. Computerized tomographic scanner with shaped radiation filter

    International Nuclear Information System (INIS)

    Carlson, R.W.; Walters, R.G.

    1981-01-01

    The invention comprises a shaped filter and a filter correction circuitry for computerized tomographic scanners. The shaped filter is a generally u-shaped block of filter material which is adapted to be mounted between the source of radiation and the scan circle. The u-shaped block has a parabolic recess. The filter material may be beryllium, aluminum, sulphur, calcium, titanium, erbium, copper, and compounds including oxides and alloys thereof. The filter correction circuit comprises a first filter correction profile adding circuit for adding a first scaler valve to each intensity valve in a data line. The data line is operated on by a beam hardness correction polynomial. After the beam hardness polynomial correction operation, a second filter correction circuit adds a second filter correction profile consisting of a table of scalor values, one corresponding to each intensity reading in the data line

  15. Computerized tomography findings in nasolacrimal dysfunction

    International Nuclear Information System (INIS)

    Ishida, Toshio; Nakamura, Yasuhisa; Kumagai, Michiasa

    1985-01-01

    We examined 17 cases (22 lesions) with stenosis or obstruction in the lacrimal drainage system with the use of computerized tomography (CT). In idio pathic cases, the site of obstruction was located either in the upper nasolacrimal duct or at the junction of the lacrimal sac and the nasolacrimal duct. In post-traumatic cases, it was located in the lower nasolacrimal duct. The obstructed areas appeared as homogenous in CT image with CT values ranging between +60 and +80. These findings were suggestive of granulation tissue. The stenosed areas appeared, on the other hand, as areas of unequal density. Lacrimal passage appeared to be maintained through the low-density portion. The CT values of the lacrimal sac was around +40 in dacryocystitis and around +20 to +30 other cases. (author)

  16. Organ doses from computerized tomography examinations

    Energy Technology Data Exchange (ETDEWEB)

    Janeczek, J.

    1995-12-31

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs.

  17. Computerized techniques for collecting the radioprotection data

    International Nuclear Information System (INIS)

    Cenusa, V.; Valeca, S.; Guta, C.; Talpalariu, C.; Stoica, V.

    2016-01-01

    An important component of a computerized radioprotection system is the module for the collection of the radioprotection data. The data collection can be made automatically from the measurement equipment or manually by the operators after they read the values measured by the mobile devices. Database systems are used for storing the data, they offer higher performances, more efficient data organization, ensure data integrity and controlled access to the data into a multiuser environment. The experimental program for the automatic collection of the remote data transfers periodically, at programmable time intervals, data files from the fixed radiation monitoring stations to a centralized system for radioprotection data. For this is used the File Transfer Protocol (FTP). A Radiation Monitoring Equipment designed and assembled in the Electronics Department of ICN Pitesti was used as a data source for the testing of the experimental programs. (authors)

  18. Computerization of a telescope at secondary education

    Science.gov (United States)

    García Santiago, A.; Martos Jumillas, J.

    2017-03-01

    The work we are presenting in this paper is the computerization of a refractor telescope on an EQ3 type equatorial mount through Arduino. The control of the mount is done via three different interfaces: Stellarium, an Android interface for mobile phones and a second interface for PC made with Processing. The aforementioned work was done by the authors with a double purpose: presenting the interest in astronomy in the Mathematics department, and the development of applications within the subject of Technology in 4th ESO. So, it is a collaborative project between both departments. Except for the telescope and the mount, all the resources we have used can be found in any high school: free software (Guadalinex v9), App Inventor and Processing.The project was carried out under the principle of reducing all possible costs given the economic possibilities of the institution.

  19. Development of computerized risk management tool

    International Nuclear Information System (INIS)

    Kil Yoo Kim; Mee Jung Hwang; Seung Cheol Jang; Sang Hoon Han; Tae Woon Kim

    1997-01-01

    The author describes the kinds of efforts for the development of computerized risk management tool; (1) development of a risk monitor, Risk Monster, (2) improvement of McFarm (Missing Cutsets Finding Algorithm for Risk Monitor) and finally (3) development of reliability database management system, KwDBMan. Risk Monster supports for plant operators and maintenance schedulers to monitor plant risk and to avoid high peak risk by rearranging maintenance work schedule. Improved McFarm significantly improved calculation speed of Risk Monster for the cases of supporting system OOS (Out Of Service). KwDBMan manages event data, generic data and CCF (Common Cause Failure) data to support Risk Monster as well as PSA tool, KIRAP (KAERI Integrated Reliability Analysis Package)

  20. Computerized tomographic evaluation of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Young; Lee, Mi Sook; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Precbyterian Medical Center, Chonju (Korea, Republic of)

    1988-08-15

    Cerebral cysticercosis, unfortunately frequent in Korea, is a parastic disease in which man serve as the intermediate host of taenia solium. The larvae have a predilection for the central nervous system and can cause a variety of neurologic symptoms. The authors reviewed 19 cases of surgically proven cerebral cysticercosis and following results were obtained. 1. The most frequent age distribution was 5th and 6th decade and male to female ratio was 14:5. 2. The most frevalent involving site was cerebral parenchyme and following by ventricles. 3. Clinical manifestations were symtom and sign of increased ICP, seizure and focal neurological dificit. 4. It was assumed that computerized tomography was the procedure of choice for the diagnosis of these parasitic brain disease.

  1. Computerized axial tomography in traumatic cervical lesions

    International Nuclear Information System (INIS)

    Koyama, Tsunemaro

    1982-01-01

    Although plain computerized axial tomography cannot routinely demonstrate the spinal cord, it does provide excellent visualization of the bony outline of the spinal canal and vertebral column. So it should be reasonable to use this technique in cases of cervical traumatic disorders. In this paper we presented 10 cases of cervical traumatic lesions; 3 atlanto-axial dislocation, 2 cervical canal stenosis, 3 OPLL, 1 intramedullary hematoma and 1 C 2 -neurinoma. In some patients neurologic deficits were induced by cervical trauma. Bony lesions appeared more adequately deliniated than intraspinal lesions, however, in some cases intramedullary changes could also be demonstrated. The use of metrizamide with high resolution CT-scanner could improve the usefullness of this technique. (author)

  2. Organ doses from computerized tomography examinations

    International Nuclear Information System (INIS)

    Janeczek, J.

    1995-01-01

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs

  3. Termination Criteria for Computerized Classification Testing

    Directory of Open Access Journals (Sweden)

    Nathan A. Thompson

    2011-02-01

    Full Text Available Computerized classification testing (CCT is an approach to designing tests with intelligent algorithms, similar to adaptive testing, but specifically designed for the purpose of classifying examinees into categories such as - pass- and - fail.- Like adaptive testing for point estimation of ability, the key component is the termination criterion, namely the algorithm that decides whether to classify the examinee and end the test or to continue and administer another item. This paper applies a newly suggested termination criterion, the generalized likelihood ratio (GLR, to CCT. It also explores the role of the indifference region in the specification of likelihood-ratio based termination criteria, comparing the GLR to the sequential probability ratio test. Results from simulation studies suggest that the GLR is always at least as efficient as existing methods.

  4. Computerized Clinical Decision Support: Contributions from 2015

    Science.gov (United States)

    Bouaud, J.

    2016-01-01

    Summary Objective To summarize recent research and select the best papers published in 2015 in the field of computerized clinical decision support for the Decision Support section of the IMIA yearbook. Method A literature review was performed by searching two bibliographic databases for papers related to clinical decision support systems (CDSSs) and computerized provider order entry (CPOE) systems. The aim was to identify a list of candidate best papers from the retrieved papers that were then peer-reviewed by external reviewers. A consensus meeting between the two section editors and the IMIA editorial team was finally conducted to conclude in the best paper selection. Results Among the 974 retrieved papers, the entire review process resulted in the selection of four best papers. One paper reports on a CDSS routinely applied in pediatrics for more than 10 years, relying on adaptations of the Arden Syntax. Another paper assessed the acceptability and feasibility of an important CPOE evaluation tool in hospitals outside the US where it was developed. The third paper is a systematic, qualitative review, concerning usability flaws of medication-related alerting functions, providing an important evidence-based, methodological contribution in the domain of CDSS design and development in general. Lastly, the fourth paper describes a study quantifying the effect of a complex, continuous-care, guideline-based CDSS on the correctness and completeness of clinicians’ decisions. Conclusions While there are notable examples of routinely used decision support systems, this 2015 review on CDSSs and CPOE systems still shows that, despite methodological contributions, theoretical frameworks, and prototype developments, these technologies are not yet widely spread (at least with their full functionalities) in routine clinical practice. Further research, testing, evaluation, and training are still needed for these tools to be adopted in clinical practice and, ultimately, illustrate

  5. Molecular Diagnostics

    OpenAIRE

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid...

  6. Computerized Provider Order Entry and Health Care Quality on Hospital Level among Pediatric Patients during 2006-2009

    Science.gov (United States)

    Wang, Liya

    2016-01-01

    This study examined the association between Computerized Physician Order Entry (CPOE) application and healthcare quality in pediatric patients at hospital level. This was a retrospective study among 1,428 hospitals with pediatric setting in Healthcare Cost and Utilization Project (HCUP) Kid's Inpatient Database (KID) and Health Information and…

  7. The Reliability and Validity of the Dominic Interactive: A Computerized Child Report Instrument for Mental Health Problems

    NARCIS (Netherlands)

    Kuijpers, R.C.W.M.; Otten, R.; Krol, N.P.C.M.; Vermulst, A.A.; Engels, R.C.M.E.

    2013-01-01

    Children and youths' self-report of mental health problems is considered essential but complicated. This study examines the psychometric properties of the Dominic Interactive, a computerized DSM-IV based self-report questionnaire and explores informant correspondence. The Dominic Interactive was

  8. The Effects of Computerized Auditory Feedback on Electronic Article Surveillance Tag Placement in an Auto-Parts Distribution Center

    Science.gov (United States)

    Goomas, David T.

    2008-01-01

    In this report from the field, computerized auditory feedback was used to inform order selectors and order selector auditors in a distribution center to add an electronic article surveillance (EAS) adhesive tag. This was done by programming handheld computers to emit a loud beep for high-priced items upon scanning the item's bar-coded Universal…

  9. A computational framework for converting textual clinical diagnostic criteria into the quality data model.

    Science.gov (United States)

    Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian

    2016-10-01

    Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Textbook on X-ray diagnostics. Substantiated by Marianne Zimmer-Brossy. 6. new rev. ed.; Lehrbuch der roentgendiagnostischen Einstelltechnik. Begruendet von Marianne Zimmer-Brossy

    Energy Technology Data Exchange (ETDEWEB)

    Becht, Stefanie [Unfallkrankenhaus Berlin (Germany). Inst. fuer Radiologie; Bittner, Roland C. [Helios Klinikum Emil von Behring, Berlin (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Ohmstede, Anke [Klinikum Oldenburg gGmbH (Germany). MTA-Schule; Pfeiffer, Andreas [Klinikum Stuttgart (Germany). Servicecenter Informationstechnik; Rossdeutscher, Reinhard [Johanniter-Krankenhaus im Flaeming, Treuenbrietzen (Germany). Abt. fuer Roentgendiagnostik

    2008-07-01

    The standard textbook on x-ray diagnostics has been revised by the MTRA team and radiologists: The book covers the following topics: General information: the profession of a radiologist, the x-ray department, radiation protection, quality assurance, basic physics, x-ray imaging, analog and digital image processing, archives, image interpretation. Skeleton diagnostics; Inner organs (thorax organs, neck, abdomen, gastrointestinal tract, colon, gall bladder and biliary tract): Special x-ray diagnostic methods: x-ray diagnostic of the female and male chest, x-ray diagnostics of bone joints (arthrography, and contrast media), x-ray diagnostics of the urinary-genital system, x-ray diagnostics of cavities and syrinx, x-ray diagnostics of arteries (arteriography, angiography), percutaneous transluminal angioplasty, x-ray diagnostics of veins (phlebography), x-ray diagnostics of lymphatic vessels and lymph nodes, x-ray diagnostics of spinal cord (myelography); Specific imaging methods: computerized tomography. [German] Ein erfahrenes Team aus MTRA und Radiologen ueberarbeitete und verbesserte das bewaehrte Standardwerk grundlegend. Detailliert, praezise und ausfuehrlich erlaeutert die 6. Neuauflage technische und physikalische Grundlagen, Strahlenschutz, alle wichtigen Einstellungen (vom Skelettsystem bis hin zur Mammadiagnostik) und aktuelle Leitlinien. Nah an der Praxis sind insbesondere die Hinweise zur Patientenvorbereitung und -lagerung, Qualitaetskriterien und Bildmerkmale sowie viele Tipps und Checklisten. Alle Einstellbilder sowie die Mehrzahl der radiologischen Aufnahmen sind erneuert. Die Kapitel zur digitalen Radiographie und den Grundlagen der MRT sind neu, die Kapitel zu CT-Protokollen und zur interventionellen Radiologie erweitert. Ein ausfuehrliches Glossar rundet das Buch ab. Insgesamt ein wertvolles und unverzichtbares Standardwerk fuer Ausbildung und Beruf. (orig.)

  11. Results of CT brain examinations in cerebrovascular emergency. [computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pinta, Z; Dolansky, J; Sorfova, J; Jerie, T

    1987-07-01

    Experience is briefly reported with CT (computerized tomography) diagnosis of cerebrovascular emergencies. It is pointed out that the introduction of computerized tomography greatly improved and made more accurate the diagnosis of focal ischemias and revealed significant differences in the foci of ischemia in hypertension patients and atherosclerosis patients without hypertension, and showed a higher incidence of intracerebral and subarachnoidal hemorrhages than previously thought. It is believed that knowledge gained thanks to CT (computerized tomography) will be of benefit to the primary and secondary prevention of cerebrovascular ischemias. (L.O.). 1 fig., 5 refs.

  12. Diagnostic information in compliance checking

    NARCIS (Netherlands)

    Ramezani Taghiabadi, E.; Fahland, D.; Aalst, van der W.M.P.

    2012-01-01

    Compliance checking is gaining importance as today's organizations need to show that operational processes are executed in a controlled manner while satisfying predefined (legal) requirements. Deviations may be costly and expose the organization to severe risks. Compliance checking is of growing

  13. What does the psychiatrist expect as to computerized tomography

    International Nuclear Information System (INIS)

    Huber, G.

    1980-01-01

    The computerized tomography (CT) can be applied also in psychiatry as an instrument of basic research. The problem of normative data as visualized by CT-scanning is up to now not yet satisfactory solved. Faulty appreciations especially on the cebral cortex in the sense of false-positive findings with possible serious social consequences are frequently. For judging of brain cortex as to atrophy primarily more basically situated sulci in various slices are taken into consideration, while the sulci of upper slices near the vertex just as the representations of cisterns, the interhemispheric fissure and Pacchionian granulations should not to be evaluated. On a new revision of the subject cerebral atrophy and irreversible psychosyndrome it is necessary and useful to compare the results of CT-scanning with those of pneumoencephalographic studies. The favourable possibilities which the CT offers also for diagnostic and research in psychiatry are to be used by critical appreciation of already existing experiences. The indication fpr TC requires complete psychiatric-neurological investigation. The interpretation of findings and the attempts to correlate them with the clinical data must take place in close cooperation with the clinical psychiatry. The neuroradiological evidence of cerebral atrophy can give hints concerning the diagnosis and prognosis only in connection with all clinical data. Findings of cerebral atrophy, combined cortical and subcortical, exclusively subcortical of preferably on the 3rd ventricle are non-specific and not characteristic of a certain disease. There are only correlations between certain types of cerebral atrophy and certain types of irreversible psychopathological syndromes. (orig.) [de

  14. Computerized heat balance models to predict performance of operating nuclear power plants

    International Nuclear Information System (INIS)

    Breeding, C.L.; Carter, J.C.; Schaefer, R.C.

    1983-01-01

    The use of computerized heat balance models has greatly enhanced the decision making ability of TVA's Division of Nuclear Power. These models are utilized to predict the effects of various operating modes and to analyze changes in plant performance resulting from turbine cycle equipment modifications with greater speed and accuracy than was possible before. Computer models have been successfully used to optimize plant output by predicting the effects of abnormal condenser circulating water conditions. They were utilized to predict the degradation in performance resulting from installation of a baffle plate assembly to replace damaged low-pressure blading, thereby providing timely information allowing an optimal economic judgement as to when to replace the blading. Future use will be for routine performance test analysis. This paper presents the benefits of utility use of computerized heat balance models

  15. Warning systems in a computerized nursing process for Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Daniela Couto Carvalho Barra

    2014-02-01

    Full Text Available A hybrid study combining technological production and methodological research aiming to establish associations between the data and information that are part of a Computerized Nursing Process according to the ICNP® Version 1.0, indicators of patient safety and quality of care. Based on the guidelines of the Agency for Healthcare Research and Quality and the American Association of Critical Care Nurses for the expansion of warning systems, five warning systems were developed: potential for iatrogenic pneumothorax, potential for care-related infections, potential for suture dehiscence in patients after abdominal or pelvic surgery, potential for loss of vascular access, and potential for endotracheal extubation. The warning systems are a continuous computerized resource of essential situations that promote patient safety and enable the construction of a way to stimulate clinical reasoning and support clinical decision making of nurses in intensive care.

  16. Computerization of nuclear material accounting and control at storage facilities of RT-1 plant, PA Mayak

    International Nuclear Information System (INIS)

    Krakhmal'nik, V.I.; Menshchikov, Yu.L.; Mozhaev, D.A.

    1999-01-01

    Computerized system for nuclear material (NM) accounting and control at RT-1 plant is being created on the basis of advanced engineering and programming tools, which give a possibility to ensure prompt access to the information required, to unify the accounting and report documentation, make statistical processing of the data, and trace the NM transfers in the chain of its storage at facilities of RT-1 plant. Currently, the accounting is performed in parallel, both by the old methods and with computerized system. The following functions are performed by the system at the current stage: input of data on the end product's (plutonium dioxide) quantitative and qualitative composition; data input on the localization of containers with finished products at storage facilities of the plant and the product's temporary characteristics; selective verification of the data on containers and batches, according to the criteria prespecified by the user; data protection against unauthorized access; data archiving; report documents formation and providing [ru

  17. Computerized training program usage at the Fort Calhoun Nuclear Power Station

    International Nuclear Information System (INIS)

    Ruzic, D.H.; Reed, W.H.; Lawton, R.K.; Fluehr, J.J.

    1987-01-01

    The increased US Nuclear Regulatory Commission and Institute of Nuclear Power Operations (INPO) interest in the nuclear power industry training programs resulted in the Omaha Public Power District staff at the Fort Calhoun Nuclear Power Station investigating the potential for computerizing their recently accredited training records, student training requirements, and the process of determining student certification status. Additional areas that were desirable were a computerized question data bank with random test generation, maintaining history of question usage, and tracking of the job task analysis process and course objectives. SCI Software's online personnel training information management system (OPTIM) was selected, subsequent to a bid evaluation, to provide these features while operating on the existing corporate IBM mainframe

  18. Seize the data (Carpe data) : wave of computerized data capture technology sweeps drilling industry

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, J.

    1999-02-01

    The computerization of all aspects of the monitoring and collection of well drilling information is discussed. Global Link International Inc. of Calgary, has developed a computerized system for tracking and recording drilling data. This operations recording database is named the Electronic Tour Book (ETB). It is similar to the Electronic Tour Sheet (ETS) developed by Chimo Equipment Ltd. of Alberta. Both Windows-based systems represent computerized reporting mechanisms for operators, producers, loggers and rig-managers. Another Alberta company, Ryan Energy Technologies Inc., has begun marketing the Tru Vu Fusion system of hardware and software, yet another system for gathering and recording drilling data. Tru Vu Fusion can capture data and display it in a format that everybody at the wellsite can use for decision making. Another drilling data management system, entitled INSITE (for Integrated System for Information Technology and Engineering) is marketed by Sperry-Sun Drilling Services. While INSITE is intended primarily for offshore drilling applications, it can be used onshore with equal success. 4 figs.

  19. Computer-Supported Information Systems.

    Science.gov (United States)

    Mayhew, William H.

    1983-01-01

    The planning and implementation of a computerized management information system at a fictional small college is described. Nine key points are made regarding department involvement, centralization, gradual program implementation, lowering costs, system documentation, and upper-level administrative support. (MSE)

  20. Information manager-2011-Vol 11

    African Journals Online (AJOL)

    Library _info_Sc_ 1

    university libraries in Lagos state that have automated their catalogues. ... Catalogues include shortage of terminals, improper working OPAC modules and ... and perpetuation of human race. ..... computerized information services so as to help.

  1. Informing Antibiotic Treatment Decisions: Evaluating Rapid Molecular Diagnostics To Identify Susceptibility and Resistance to Carbapenems against Acinetobacter spp. in PRIMERS III.

    Science.gov (United States)

    Evans, Scott R; Hujer, Andrea M; Jiang, Hongyu; Hill, Carol B; Hujer, Kristine M; Mediavilla, Jose R; Manca, Claudia; Tran, Thuy Tien T; Domitrovic, T Nicholas; Higgins, Paul G; Seifert, Harald; Kreiswirth, Barry N; Patel, Robin; Jacobs, Michael R; Chen, Liang; Sampath, Rangarajan; Hall, Thomas; Marzan, Christine; Fowler, Vance G; Chambers, Henry F; Bonomo, Robert A

    2017-01-01

    The widespread dissemination of carbapenem-resistant Acinetobacter spp. has created significant therapeutic challenges. At present, rapid molecular diagnostics (RMDs) that can identify this phenotype are not commercially available. Two RMD platforms, PCR combined with electrospray ionization mass spectrometry (PCR/ESI-MS) and molecular beacons (MB), for detecting genes conferring resistance/susceptibility to carbapenems in Acinetobacter spp. were evaluated. An archived collection of 200 clinical Acinetobacter sp. isolates was tested. Predictive values for susceptibility and resistance were estimated as a function of susceptibility prevalence and were based on the absence or presence of beta-lactamase (bla) NDM, VIM, IMP, KPC, and OXA carbapenemase genes (e.g., bla OXA-23 , bla OXA-24/40 , and bla OXA-58 found in this study) against the reference standard of MIC determinations. According to the interpretation of MICs, 49% (n = 98) of the isolates were carbapenem resistant (as defined by either resistance or intermediate resistance to imipenem). The susceptibility sensitivities (95% confidence interval [CI]) for imipenem were 82% (74%, 89%) and 92% (85%, 97%) for PCR/ESI-MS and MB, respectively. Resistance sensitivities (95% CI) for imipenem were 95% (88%, 98%) and 88% (80%, 94%) for PCR/ESI-MS and MB, respectively. PRIMERS III establishes that RMDs can discriminate between carbapenem resistance and susceptibility in Acinetobacter spp. In the context of a known prevalence of resistance, SPVs and RPVs can inform clinicians regarding the best choice for empiric antimicrobial therapy against this multidrug-resistant pathogen. Copyright © 2016 American Society for Microbiology.

  2. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently....... Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...

  3. Computerized Point of Sale = Faster Service + Better Accountability.

    Science.gov (United States)

    Pannell, Dorothy V.

    1991-01-01

    Describes selecting and installing a computerized point of sale for a district food service program; the equipment needed and preferred; and the training of trainers, managers, and cashiers. Also discusses the direct benefits and side benefits of the system. (MLF)

  4. 381 Developing of a Computerized Brain Diagnosing System for ...

    African Journals Online (AJOL)

    User

    Ogunsanwo O. D. - Department of Computer Science, Gate way ICT ... computerized brain diagnosing system that would be used in carrying out the ..... This aspect explores the techniques use for the design of interface, menus and databases ...

  5. Computerized Tomography and its Applications : a Guided Tour

    NARCIS (Netherlands)

    Roerdink, J.B.T.M.

    1992-01-01

    We present a review of the mathematical principles of computerized tomography. Topics treated include the role of the Radon transform and related transforms, inversion formulas, uniqueness, ill-posedness and stability, practical reconstruction algorithms, and various generalizations such as

  6. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  7. Survey of methods for improving operator acceptance of computerized aids

    International Nuclear Information System (INIS)

    Frey, P.R.; Kisner, R.A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room

  8. Development of a computerized handbook of architectural plans

    NARCIS (Netherlands)

    Koutamanis, A.

    1990-01-01

    The dissertation investigates an approach to the development of visual / spatial computer representations for architectural purposes through the development of the computerized handbook of architectural plans (chap), a knowledge-based computer system capable of recognizing the metric properties of

  9. Survey of methods for improving operator acceptance of computerized aids

    Energy Technology Data Exchange (ETDEWEB)

    Frey, P. R.; Kisner, R. A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room.

  10. Computerized tomographic evaluation of aortic prosthetic graft complications

    International Nuclear Information System (INIS)

    Kay, D.; Kalmar, J.A.

    1985-01-01

    Computerized tomography has been found to be an accurate and sensitive method of diagnosing complications of synthetic aortic grafts. Complications in this series of four cases included aortoesophageal fistula, aortoduodenal fistula, pseudoaneurysm, and retroperitoneal hematoma. 6 references, 5 figures

  11. Computerized Analysis and Detection of Missed Cancer in Screening Mammogram

    National Research Council Canada - National Science Library

    Li, Lihua

    2005-01-01

    This project is to explore an innovative CAD strategy for improving early detection of breast cancer in screening mammograms by focusing on computerized analysis and detection of cancers missed by radiologists...

  12. Computerized Analysis and Detection of Missed Cancer in Screening Mammogram

    National Research Council Canada - National Science Library

    Li, Lihua

    2004-01-01

    This project is to explore an innovative CAD strategy for improving early detection of breast cancer in screening mammograms by focusing on computerized analysis and detection of cancers missed by radiologists...

  13. Journal of EEA, Vol. 30, 2013 COMPUTERIZED FACILITIES ...

    African Journals Online (AJOL)

    dell

    Key words: Computer Aided Layout Design,. Construction ... Commonly used software are ... popular improvement-type methods are. Computerized Relative Allocation of Facilities .... closeness ratings values are given different numerical.

  14. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  15. Computerized systems of NPP operators support. (Psychological problems)

    International Nuclear Information System (INIS)

    Mashin, V.A.

    1995-01-01

    Operator psychological problems arising in the work with NPP operators support computerized systems (OSCS) are considered. The conclusion is made that the OSCS intellectual application will bring the operator into dangerous dependence on his computerized assistant. To avoid this danger it is necessary by creation of the OSCS to divide specially the tasks areas of the operator and OSCS in order to assure the active role of the operator in the NPP control

  16. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  17. Computerized adaptive testing--ready for ambulatory monitoring?

    DEFF Research Database (Denmark)

    Rose, Matthias; Bjørner, Jakob; Fischer, Felix

    2012-01-01

    Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted.......Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted....

  18. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which is consisted of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for filed geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  19. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zhou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which consists of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for field geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  20. Single photon emission computerized tomography (SPECT)

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as 123 I and 99 Tc m that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  1. Computerized 50 liter volume calibration system

    International Nuclear Information System (INIS)

    Proffitt, T.H.

    1990-01-01

    A system has been designed for the Savannah River Site that will be used to calibrate product shipping containers. For accountability purposes, it is necessary that these containers be calibrated to a very high precision. The Computerized 50 Liter Volume Calibration System (CVCS), which is based on the Ideal Gas Law (IGL), will use reference volumes with precision of no less ±0.03%, and helium to calibrate the containers to have a total error of no greater than ±0.10%. A statistical interpretation of the system has given a theoretical total calculated error of ±0.08%. Tests with the system will be performed once fabrication is complete to experimentally verify the calculated error. Since the total error was calculated using the worst case scenario, the actual error should be significantly less than the calculated value. The computer controlled, totally automated system is traceable to the National Institute of Standards and Technology. The design, calibration procedure, and statistical interpretation of the system will be discussed. 1 ref

  2. Computerized portable microwave hyperthermia quality assurance kit

    International Nuclear Information System (INIS)

    Cheung, A.Y.; Neyzari, A.

    1985-01-01

    A computerized quality assurance kit to provide precise measurement and calibration of microwave power and temperature, as well as capabilities to map SAR (Specific absorption rate) distribution in phantoms; and survey of hazardous microwave leakage has been designed. The kit is also capable of performing corelation studies on the relationship between SAR and net microwave power delivered at various anatomical sites. The kit consists of a portable microcomputer, a time-multiplexed A/D converter, a 4-channel dual directional microwave power monitor, a 4-channel thin-wire thermocouple thermometry system, an electronic thermal calibrator, a microwave leakage hazard survey meter, and a dynamic phantom tank for dosimetric analysis. Comparative performance studies were made against NBS-traceable power and temperature standards, non-perturbing optical temperature sensors, and established power and temperature measurement devices. The test results indicate that this instrument is providing its user with measurement accuracy of 0.1 0 C in temperature, 10% accuracy in power. The thin-wire thermocouple, with computer assisted error compensation, performs equally well in a strong microwave field in comparison with non-perturbing optical temperature sensors

  3. Single photon emission computerized tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as {sup 123}I and {sup 99}Tc{sup m} that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  4. Study on forefoot by computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Machida, Eiichi (Nihon Univ., Tokyo. School of Medicine)

    1983-10-01

    Computerized tomography (CT) was used to study coronary sections of the forefoot in both normal and abnormal human feet. CT images of the transverse arches at the metatarsal head, middle and base of the shaft were classified into five patterns. In the pattern most commonly found in normal feet, the second metatarsus appeared elevated above the other metatarsal bones at all points, and there was a gradual and even reduction in elevation from the second to the fifth metatarsal. In cases of hallux valgus, however, a variety of deformities were noted in the arc of the second to fifth metatarsals, particularly at the head. The rotation of the first metatarsus and shift of the sesamoids were measured from CT images at the head of the first metatarsus. In hallux valgus, both the rotation and the sesamoid shift appeared to have a wider angle than in the case of normal feet. In normal feet, the differences between the rotation of the first metatarsus and shift of the sesamoids were relatively small, whereas in hallux valgus there was a much greater degree of variation. Furthermore, while normal feet the variation in rotation of the first metatarsus and sesamoid shift both tended to be either great or small, in hallux valgus a large degree of sesamoid shift was sometimes found in combination with a small degree of rotation of the first metatarsus.

  5. Study on forefoot by computerized tomography

    International Nuclear Information System (INIS)

    Machida, Eiichi

    1983-01-01

    Computerized tomography (CT) was used to study coronary sections of the forefoot in both normal and abnormal human feet. CT images of the transverse arches at the metatarsal head, middle and base of the shaft were classified into five patterns. In the pattern most commonly found in normal feet, the second metatarsus appeared elevated above the other metatarsal bones at all points, and there was a gradual and even reduction in elevation from the second to the fifth metatarsal. In cases of hallux valgus, however, a variety of deformities were noted in the arc of the second to fifth metatarsals, particularly at the head. The rotation of the first metatarsus and shift of the sesamoids were measured from CT images at the head of the first metatarsus. In hallux valgus, both the rotation and the sesamoid shift appeared to have a wider angle than in the case of normal feet. In normal feet, the differences between the rotation of the first metatarsus and shift of the sesamoids were relatively small, whereas in hallux valgus there was a much greater degree of variation. Furthermore, while normal feet the variation in rotation of the first metatarsus and sesamoid shift both tended to be either great or small, in hallux valgus a large degree of sesamoid shift was sometimes found in combination with a small degree of rotatin of the first metatarsus. (author)

  6. Implementing of the nuclear materials accounting and control computerized system at JINR

    International Nuclear Information System (INIS)

    Dobryanskij, V.M.; Kalyakin, N.N.; Koltin, G.P.; Samojlov, V.N.; Cheker, A.V.; Shestakov, B.A.

    2000-01-01

    The results of the development of the computerized nuclear materials accounting system at the Joint Institute for Nuclear Research (JINR) are submitted. This work was carried out under Russian-American Nuclear Materials Protection, Control and Accounting (MPCandA) Program. The System was implemented at the Institute, it was attested to work with sensitive information. The computerized information nuclear materials accounting and control system, named MTIS (Materials Tracking Information System), is intended for the automated accounting of the nuclear materials used in JINR, tracking their moving, changes of their inventory amounts, preparation of the required documentation, and also for information support of the measures spent in the JINR on MPCandA program. MTIS can prepare reports for federal level and can also generate data to be reported for internal purposes. MTIS includes as one of the subsystems a program module to prepare reporting information to the Federal Information System (FIS). The system MTIS provides control of access to the database (DB), protection of the information against the non-authorized access, division of the data into the sensitive and non-sensitive data. (author)

  7. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  8. Expert knowledge for computerized ECG interpretation

    NARCIS (Netherlands)

    J.A. Kors (Jan)

    1992-01-01

    textabstractIn this study, two main questions are addressed: (1) Can the time consuming and cumbersome development and refinement of (heuristic) ECG classifiers be alleviated, and (2) Is it possible to increase diagnostic performance of ECG computer programs by combining knowledge from multiple

  9. Development of a computerized adaptive test for Schizotypy assessment.

    Directory of Open Access Journals (Sweden)

    Eduardo Fonseca-Pedrero

    Full Text Available BACKGROUND: Schizotypal traits in adolescents from the general population represent the behavioral expression of liability for psychotic disorders. Schizotypy assessment in this sector of population has advanced considerably in the last few years; however, it is necessary to incorporate recent advances in psychological and educational measurement. OBJECTIVE: The main goal of this study was to develop a Computerized Adaptive Test (CAT to evaluate schizotypy through "The Oviedo Questionnaire for Schizotypy Assessment" (ESQUIZO-Q, in non-clinical adolescents. METHODS: The final sample consisted of 3,056 participants, 1,469 males, with a mean age of 15.9 years (SD=1.2. RESULTS: The results indicated that the ESQUIZO-Q scores presented adequate psychometric properties under both Classical Test Theory and Item Response Theory. The Information Function estimated using the Gradual Response Model indicated that the item pool effectively assesses schizotypy at the high end of the latent trait. The correlation between the CAT total scores and the paper-and-pencil test was 0.92. The mean number of presented items in the CAT with the standard error fixed at ≤ 0.30 was of 34 items. CONCLUSION: The CAT showed adequate psychometric properties for schizotypy assessment in the general adolescent population. The ESQUIZO-Q adaptive version could be used as a screening method for the detection of adolescents at risk for psychosis in both educational and mental health settings.

  10. The Initial Development of a Computerized Operator Support System

    Energy Technology Data Exchange (ETDEWEB)

    Roger Lew; Ronald L Boring; Thomas A Ulrich; Ken Thomas

    2014-08-01

    A computerized operator support system (COSS) is a collection of resilient software technologies to assist operators in monitoring overall nuclear power plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast- moving, complex events. A prototype COSS for a chemical volume control system at a nuclear power plant has been developed in order to demonstrate the concept and provide a test bed for further research. The development process identified four underlying elements necessary for the prototype, which consist of a digital alarm system, computer-based procedures, piping and instrumentation diagram system representations, and a recommender module for mitigation actions. An operational prototype resides at the Idaho National Laboratory (INL) using the U.S. Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). Several human-machine interface (HMI) considerations are identified and incorporated in the prototype during this initial round of development.

  11. Positron transaxial emission tomograph with computerized image reconstruction

    International Nuclear Information System (INIS)

    Jatteau, Michel.

    1981-01-01

    This invention concerns a positron transaxial emission tomography apparatus with computerized image reconstruction, like those used in nuclear medicine for studying the metabolism of organs, in physiological examinations and as a diagnosis aid. The operation is based on the principle of the detection of photons emitted when the positrons are annihilated by impact with an electron. The appliance is mainly composed of: (a) - a set of gamma ray detectors distributed on a polygonal arrangement around the body area to be examined, (b) - circuits for amplifying the signals delivered by the gamma ray detectors, (c) - computers essentially comprising energy integration and discrimination circuits and provided at the output of the detectors for calculating and delivering, as from the amplified signals, information on the position and energy relative to each occurrence constituted by the detections of photons, (d) - time coincidence circuits for selecting by emission of detector validation signals, only those occurrences, among the ensemble of those detected, which effectively result from the annihilation of positrons inside the area examined, (e) - a data processing system [fr

  12. Potential of Computerized Maintenance Management System in Facilities Management

    Directory of Open Access Journals (Sweden)

    Noor Farisya Azahar

    2014-07-01

    Full Text Available For some time it has been clear that managing buildings or estates has been carried out in the context of what has become known as facilities management. British Institute of Facilities Management defined facilities management is the integration of multi-disciplinary activities within the built environment and the management of their impact upon people and the workplace. Effective facilities management is vital to the success of an organisation by contributing to the delivery of its strategic and operational objectives. Maintenance of buildings should be given serious attention before (stage design, during and after a building is completed. But total involvement in building maintenance is after the building is completed and during its operations. Residents of and property owners require their building to look attractive, durable and have a peaceful indoor environment and efficient. The objective of the maintenance management system is to stream line the vast maintenance information system to improve the productivity of an industrial plant. a good maintenance management system makes equipment and facilities available. This paper will discuss the fundamental steps of maintenance management program and Computerized Maintenance Management System (CMMS

  13. Development of BWR computerized operator support system for emergency conditions

    International Nuclear Information System (INIS)

    Murata, F.

    1984-01-01

    A BWR computerized operator support system (COSS) for emergency conditions has been under development for three years. The conceptual design of the system has been settled and some of the subsystems are in the detailed design or manufacturing stage. The principal functions are technical specification monitoring, diagnosis, guidance during emergency conditions, predictive simulation and safety monitoring. Before a reactor trip, alternative operational guidance for anomalous events is provided by utilization of the CTT (cause consequence tree) and FPS (failure propagation simulator). After the trip, operational guidance is based on event-oriented and symptom-oriented methods in association with the safety function monitor. The technical specification monitor controls the readiness monitor and performs surveillance tests of safety systems to maintain plant operational reliability and to ensure correct performance when initiated. The predictive simulator gives the future trends of significant plant parameters. These subsystems are expected to assist the operational personnel. The feasibility of the COSS functions is confirmed separately by off-line simulation. The paper considers the conceptual design, the functions of the subsystems and the off-line simulation results. Each subsystem has shown that useful information to operational personnel is provided. Henceforth these functions will be integrated into a single system and the feasibility will be thoroughly evaluated using a plant simulator which is being separately developed to verify the COSS. (author)

  14. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  15. A new Brief computerized cognitive screening battery (CompCogs for early diagnosis of Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Helenice Charchat Fichman

    Full Text Available Abstract Screening tests for early diagnosis of dementia are of great clinical relevance. The ideal test set must be brief and reliable, and should probe cognitive components impaired in Alzheimer's disease (AD. Objectives: To develop a new Computerized Cognitive Screening test (CompCogs, and to investigate its validity for the early diagnosis of AD, and evaluate its heuristic value in understanding the processing of information in AD. Methods: The computerized neuropsychological performance battery, originally including six tests, was applied in forty seven patients with probable mild AD and 97 controls matched for age and education. This computerized neuropsychological test battery, developed with MEL Professional, allows control of timing and order of stimuli presentation, as well as recording of response type and latency. A brief-screening version, CompCogs, was selected using the most discriminative neuropsychological test variables derived from logistic regression analysis. Full battery administration lasted about 40 minutes, while the CompCogs took only 15 minutes. Results: CompCogs included the Face test (correct response and Word and Forms with Short term memory tests (reaction time. CompCogs presented 91.8% sensitivity and 93.6% specificity for the diagnosis of AD using ROC analyses of AD diagnosis probability derived by logistic regression. Conclusions: CompCogs showed high validity for AD early diagnosis and, therefore, may be a useful alternative screening instrument.

  16. Enhancing the efficacy of computerized feedback interventions for college alcohol misuse: An exploratory randomized trial.

    Science.gov (United States)

    Miller, Mary Beth; Leavens, Eleanor L; Meier, Ellen; Lombardi, Nathaniel; Leffingwell, Thad R

    2016-02-01

    Personalized feedback interventions (PFIs) have been associated with decreased alcohol consumption and related problems among college students; however, the necessary and sufficient components responsible for efficacy remain unclear. The present study investigated the relative efficacy of 3 computerized PFIs with differing content, the content-specific mechanisms of change within PFIs, and the moderating roles of comparison orientation and baseline risk in intervention outcomes. College students (N = 212) reporting alcohol use in a typical week completed an assessment prior to randomization (norms PFI, enhanced PFI, choice PFI, assessment only) and 1 month postintervention. Participants who received a PFI reported greater decreases in alcohol use, peak blood alcohol concentration (BAC), related problems, and perceptions of typical students' drinking than those in the control group. Neither tendency to compare oneself with others nor baseline risk moderated outcomes. PFIs influenced weekly alcohol use indirectly through changes in descriptive normative perceptions and alcohol-related consequences indirectly through changes in peak BAC. Computerized PFIs are more effective than assessment alone in decreasing alcohol use and related problems among college students. Normative comparisons may be sufficient to elicit behavior change, and inclusion of select additional components may not yield significant improvements in outcomes. However, the consistent benefit of including feedback on physical and monetary costs of drinking and moderation strategies, although nonsignificant, may warrant the negligible increase in time and money required to provide such information electronically. Computerized PFIs seem to be an ideal first step to the prevention and treatment of college alcohol misuse. (c) 2016 APA, all rights reserved).

  17. Clinical Use of the Pediatric Attention Disorders Diagnostic Screener for Children at Risk for Attention Deficit Hyperactivity Disorder: Case Illustrations

    Science.gov (United States)

    Keiser, Ashley; Reddy, Linda

    2013-01-01

    The Pediatric Attention Disorders Diagnostic Screener is a multidimensional, computerized screening tool designed to assess attention and global aspects of executive functioning in children at risk for attention disorders. The screener consists of a semi-structured diagnostic interview, brief parent and teacher rating scales, 3 computer-based…

  18. Feasibility of computerized screening for intimate partner violence in a pediatric emergency department.

    Science.gov (United States)

    Scribano, Philip V; Stevens, Jack; Marshall, Jessica; Gleason, Erica; Kelleher, Kelly J

    2011-08-01

    This study aimed to evaluate the feasibility of caregiver-initiated computerized screening in a pediatric emergency department (ED) to identify home safety risks, with a specific emphasis on intimate partner violence (IPV). Home safety screening kiosks were developed using information technology as the first step in a plan to decrease family violence. Caregivers self-initiated a standard-of-care screening process that included both non-IPV and IPV items. An ED social worker received an automated text page and printed summary of the findings when a caregiver endorsed IPV. System activity was tracked by comparing frequency of completed screens to the daily ED census and by determining the percentage of completed screens that were positive for IPV. The reliability of the technology was evaluated as percentage of days of system downtime. Meetings with ED personnel and direct observations of families were conducted to identify potential barriers and successes to the technology utilization. During a 15-month period, 13,057 computerized screens occurred, with a 4-fold increase in the computerized screening rate after ED triage nurses became champions of these efforts. Fourteen percent of the computerized screens were positive for IPV. The reliability of the technology was considered quite high, with rare system downtime (4.2% of days) reported during the 15 months. There were several themes identified by caregivers and providers regarding barriers to successful use of the safety screening. A reliable, caregiver-initiated system is possible to offer consistent opportunity to conduct unobtrusive, private screening for IPV and other home safety concerns.

  19. Implementation of a Computerized Screening Inventory: Improved Usability Through Iterative Testing and Modification.

    Science.gov (United States)

    Boudreaux, Edwin D; Fischer, Andrew Christopher; Haskins, Brianna Lyn; Saeed Zafar, Zubair; Chen, Guanling; Chinai, Sneha A

    2016-03-09

    The administration of health screeners in a hospital setting has traditionally required (1) clinicians to ask questions and log answers, which can be time consuming and susceptible to error, or (2) patients to complete paper-and-pencil surveys, which require third-party entry of information into the electronic health record and can be vulnerable to error and misinterpretation. A highly promising method that avoids these limitations and bypasses third-party interpretation is direct entry via a computerized inventory. To (1) computerize medical and behavioral health screening for use in general medical settings, (2) optimize patient acceptability and feasibility through iterative usability testing and modification cycles, and (3) examine how age relates to usability. A computerized version of 15 screeners, including behavioral health screeners recommended by a National Institutes of Health Office of Behavioral and Social Sciences Research collaborative workgroup, was subjected to systematic usability testing and iterative modification. Consecutive adult, English-speaking patients seeking treatment in an urban emergency department were enrolled. Acceptability was defined as (1) the percentage of eligible patients who agreed to take the assessment (initiation rate) and (2) average satisfaction with the assessment (satisfaction rate). Feasibility was defined as the percentage of the screening items completed by those who initiated the assessment (completion rate). Chi-square tests, analyses of variance, and Pearson correlations were used to detect whether improvements in initiation, satisfaction, and completion rates were seen over time and to examine the relation between age and outcomes. Of 2157 eligible patients approached, 1280 agreed to complete the screening (initiation rate=59.34%). Statistically significant increases were observed over time in satisfaction (F3,1061=3.35, P=.019) and completion rates (F3,1276=25.44, PUsability testing revealed several critical

  20. Performance assessment and beamline diagnostics based on evaluation of temporal information from infrared spectral datasets by means of R Environment for statistical analysis.

    Science.gov (United States)

    Banas, Krzysztof; Banas, Agnieszka; Gajda, Mariusz; Kwiatek, Wojciech M; Pawlicki, Bohdan; Breese, Mark B H

    2014-07-15

    Assessment of the performance and up-to-date diagnostics of scientific equipment is one of the key components in contemporary laboratories. Most reliable checks are performed by real test experiments while varying the experimental conditions (typically, in the case of infrared spectroscopic measurements, the size of the beam aperture, the duration of the experiment, the spectral range, the scanner velocity, etc.). On the other hand, the stability of the instrument response in time is another key element of the great value. Source stability (or easy predictable temporal changes, similar to those observed in the case of synchrotron radiation-based sources working in non top-up mode), detector stability (especially in the case of liquid nitrogen- or liquid helium-cooled detectors) should be monitored. In these cases, recorded datasets (spectra) include additional variables such as time stamp when a particular spectrum was recorded (in the case of time trial experiments). A favorable approach in evaluating these data is building hyperspectral object that consist of all spectra and all additional parameters at which these spectra were recorded. Taking into account that these datasets could be considerably large in size, there is a need for the tools for semiautomatic data evaluation and information extraction. A comprehensive R archive network--the open-source R Environment--with its flexibility and growing potential, fits these requirements nicely. In this paper, examples of practical implementation of methods available in R for real-life Fourier transform infrared (FTIR) spectroscopic data problems are presented. However, this approach could easily be adopted to many various laboratory scenarios with other spectroscopic techniques.

  1. Diagnostic utility of the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) and its combination with the Addenbrooke's Cognitive Examination-Revised (ACE-R) in a memory clinic-based population.

    Science.gov (United States)

    Hancock, P; Larner, A J

    2009-06-01

    The study aimed to assess the clinical utility of the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) in patients referred to memory clinics, alone and in combination with the Addenbrooke's Cognitive Examination-Revised (ACE-R) and the Mini-mental State Examination (MMSE). This pragmatic prospective study was based on consecutive referrals attending with an informant (n = 144) to two memory clinics over a 12-month period. Patients were diagnosed using standard clinical diagnostic criteria for dementia (DSM-IV) as gold standard (dementia prevalence = 59%). The IQCODE was administered to informants, and the ACE-R and/or MMSE to most patients. The IQCODE proved acceptable to informants, and was quick and easy to use. Using traditional parameters of diagnostic utility (sensitivity, specificity, positive predictive value, likelihood ratios), the performance of the IQCODE at optimal test accuracy was highly sensitive (0.86) for the diagnosis of dementia but specificity was poor (0.39) with suboptimal positive predictive value (0.67) and small or unimportant likelihood ratios. Overall diagnostic accuracy based on area under the receiver operating characteristic (ROC) curve was 0.71. Combining the IQCODE with either ACE-R or MMSE greatly improved accuracy, specificity and positive predictive value when the tests were used in series, but not when used in parallel. In a memory clinic based population, the IQCODE proved sensitive for the diagnosis of dementia but overall diagnostic accuracy was suboptimal. Combining the IQCODE in series with the ACE-R or MMSE greatly improved diagnostic utility.

  2. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  3. Computerized tomographic evaluation of primary brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Ok; Lee, Jong Soon; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Presbyterian Mediacal center, Cheonju (Korea, Republic of); Kim, Jong Deok [Inje Medical College, Paik Hospital, Pusan (Korea, Republic of)

    1985-10-15

    In a study of primary brain tumors 104 cases having satisfactory clinical, operative and histological proofs were analyzed by computerized tomography at Presbyterian Medical Center from May, 1982 to April 1985. The results were as follows: 1. The male to female ratio of primary brain tumor was 54 : 46. 2. The 2nd decade group (26%) was the most prevalent age group, followed by the 5th decade (16.3%), 1st decade (14.4%) , 3rd decade (12.5%), 4th decade (11.5%), 6th decade (10.6%), 7th decade (8.7%) in that order. 3. The incidence of primary brain tumors was found to be: glioma 64 cases (61.6%) among the GM, the most frequent 17 cases (16.3%), followed by meningioma 12 cases (11.5%), pituitary adenoma 10 cases (9.6%), craniopharyngioma 6 cases (5.8%), pinealoma and germinoma 3 cases (2.9%) respectively, and dermoid cyst 2 cases (1.9%) in that order. 4. The location of the primary brain tumors were as follows: cb. hemisphere (49%) of these 24.5% in parietal region, 11.9% in temporal region, 9.7% in frontal region, 3.0% in occipital region: juxtasella area (16.3%), cerebellar hemisphere (8.7%), parapineal and intraventricle (7.7%) respectively, cerebello-pontine angle area (5.8%), vermis and 4th ventricular region (4.8%). 5. There were no remarkable differences in the findings of pre- and post-contrast CT scanning of primary brain tumors computed with others.

  4. Neurosurgical operating computerized tomographic scanner system

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi.

    1988-01-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place. (author)

  5. Integrated System Validation Usability Questionnaire: Computerized Procedures

    International Nuclear Information System (INIS)

    Garcés, Ma. I.; Torralba, B.

    2015-01-01

    The Research and Development (R&D) project on “Theoretical and Methodological Approaches to Integrated System Validation of Control Rooms, 2014-2015”, in which the research activities described in this report are framed, has two main objectives: to develop the items for an usability methodology conceived as a part of the measurement framework for performance-based control room evaluation that the OECD Halden Reactor Project will test in the experiments planned for 2015; and the statistical analysis of the data generated in the experimental activities of the Halden Man-Machine Laboratory (HAMMLAB) facility, with previous usability questionnaires, in 2010 and 2011. In this report, the procedure designed to meet the first goal of the project is described, in particular, the process followed to identify the items related to operating procedures, both computer and paper-based, one of the elements to be included in the usability questionnaire. Three phases are performed, in the first one, the approaches developed by the United States Nuclear Regulatory Commission, NRC, are reviewed, the models used by the nuclear industry and their technical support organizations, mainly, the Electric Power Research Institute, EPRI, are analyzed, and scientist advances are also explored. In the remaining stages, general and specific guidelines for computerized and paper-based procedures are compared and criteria for the preliminary selection of the items that should be incorporated into the usability questionnaire are defined. This proposal will be reviewed and adapted by the Halden Reactor Project to the design of the specific experiments performed in HAMLAB.

  6. Comparative evaluations of the results of common X-ray examinations and computerized tomography in patients with exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Khomenko, A.G.; Dmitrieva, L.I.; Khikkel', Kh.G.; Myuller, S.

    1989-01-01

    A correlative study of the results of x-ray examination using routine methods and computerized tomography (CT) was conducted to specify the roentgenomorphological substrate of changes in patients with exogenous allergic alveolitis. The established complex of routine methods is informative enough to interpret the revealed changes. However, at early stages CT helps to specify semiotics and permits obtaining additional information, particularly on quantitative, i.e. densitometric changes. In diffuse and disseminated pulmonary lesions CT can be used as an additional method

  7. Information technologies in biomedicine

    CERN Document Server

    Kawa, Jacek; Wieclawek, Wojciech

    2014-01-01

    New computerized approaches to various problems have become critically important in healthcare. Computer assisted diagnosis has been extended towards a support of the clinical treatment. Mathematical information analysis, computer applications have become standard tools underpinning the current rapid progress with developing Computational Intelligence. A computerized support in the analysis of patient information and implementation of a computer aided diagnosis and treatment systems, increases the objectivity of the analysis and speeds up the response to pathological changes. This book presents a variety of state-of-the-art information technology and its applications to the networked environment to allow robust computerized approaches to be introduced throughout the healthcare enterprise. Image analysis and its application is the traditional part that deals with the problem of data processing, recognition and classification. Bioinformatics has become a dynamically developed field of computer assisted biologic...

  8. Computerized electrocardiography in American pit bull terrier dogsEletrocardiografia computadorizada em cães da raça American pit bull terrier

    Directory of Open Access Journals (Sweden)

    Mauro José Lahm Cardoso

    2013-10-01

    Full Text Available Electrocardiography (ECG is an essential examination for evaluation of patient with heart disease is great importance the diagnosis of arrhythmias. The examination can determine source f rhythm and frequency depolarization heart, providing information in clinical status myocardium, since deflections P-QRS-T tracing can be altered by disease or physiological factor. With advancement of computer technology, computerized electrocardiography has been used in human medicine as auxiliary diagnostic method and currently is being increasingly used in veterinary medicine. The objectives this study were to study e computerized electrocardiographic parameters in dogs breed American Pit Bull Terrier, comparing them with patterns species. In present study, we evaluated electrocardiographic examinations 42 dogs the breed American Pit Bull clinically healthy, 22 males and 20 females, aged between 1 and 6 years. Sinus rhythm was observed in 57% of dogs showed sinus rhythm and only 26% were wandering pacemaker. The electrocardiographic values obtained from these dogs computerized ECG were within the normal range of species, except the duration of the P wave which had longer than 0.04 seconds in 24% of dogs. We conclude that the dogs of the breed American Pit Bull Terrier have the same electrocardiographic values obtained in other breeds by the computerized method, except for the increase in P-wave duration. A eletrocardiografia (ECG é um exame essencial para avaliação do paciente com doença cardíaca, sendo de grande importância para o diagnóstico das arritmias. O exame pode determinar a origem do ritmo e a freqüência de despolarização do coração, fornecendo informações do estado clínico do miocárdio, uma vez que as deflexões P-QRS-T do traçado podem ser alteradas por uma enfermidade ou fator fisiológico. Com o avanço da informática, a eletrocardiografia computadorizada tem sido utilizada na medicina humana e veterinária como método de

  9. Diagnostic dilemma

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Dobrovolny, Robert; Nazarenko, Irina

    2011-01-01

    Fabry disease, an X-linked lysosomal storage disorder, results from the deficient activity of a-galactosidase A (a-Gal A). In affected males, the clinical diagnosis is confirmed by the markedly decreased a-Gal A activity. However, in female heterozygotes, the a-Gal A activity can range from low t...... on enzyme replacement therapy. Thus, gene dosage analyses can detect large deletions (>50bp) in suspect heterozygotes for X-linked and autosomal dominant diseases that are "sequencing cryptic," resolving molecular diagnostic dilemmas....... to normal due to random X-chromosomal inactivation, and diagnostic confirmation requires identification of the family's a-Gal A gene mutation. In a young female who had occasional acroparesthesias, corneal opacities, and 15 to 50% of the lower limit of normal leukocyte a-Gal A activity, a-Gal A sequencing...... in two expert laboratories did not identify a confirmatory mutation, presenting a diagnostic dilemma. A renal biopsy proved diagnostic and renewed efforts to detect an a-Gal A mutation. Subsequent gene dosage analyses identified a large a-Gal A deletion confirming her heterozygosity, and she was started...

  10. Significance of cranial computerized tomography for diagnosis and therapy of inflammatory diseases of the brain and meninges in children

    Energy Technology Data Exchange (ETDEWEB)

    Kotlarek, F; Hauke, P; Zeumer, H [Technische Hochschule Aachen (Germany, F.R.). Abt. Kinderheilkunde; Technische Hochschule Aachen (Germany, F.R.). Abt. Neurologie)

    1979-01-01

    The significance of cranial computerized tomography (CCT) for the diagnosis and therapy of inflammatory diseases of the central nervous system in children is discussed in connection with five characteristic case studies. CCT is shown to be superior to classical neuroradiological approaches, and to allow important diagnostic insights: 1. the early recognition of diffuse brain edema and the resulting possibility of an early begin of therapy - 2. the pathological expansions of the cerebral ventricles of various etiology before a pathological enlargement of the head can be detected, and the size of the ventricles after neurosurgical therapy can be measured - 3. the early recognition of space-occupying inflammatory complications.

  11. Computerized photogrammetry used to calculate the brow position index.

    Science.gov (United States)

    Naif-de-Andrade, Naif Thadeu; Hochman, Bernardo; Naif-de-Andrade, Camila Zirlis; Ferreira, Lydia Masako

    2012-10-01

    The orbital region is of vital importance to facial expression. Brow ptosis, besides having an impact on facial harmony, is a sign of aging. Various surgical techniques have been developed to increase the efficacy of brow-lift surgery. However, no consensus method exists for an objective measurement of the eyebrow position due to the curvature of the face. Therefore, this study aimed to establish a method for measuring the eyebrow position using computerized photogrammetry. For this study, 20 orbital regions of 10 volunteers were measured by direct anthropometry using a digital caliper and by indirect anthropometry (computerized photogrammetry) using standardized digital photographs. Lines, points, and distances were defined based on the position of the anthropometric landmarks endocanthion and exocanthion and then used to calculate the brow position index (BPI). Statistical analysis was performed using Student's t test with a significance level of 5 %. The BPI values obtained by computerized photogrammetric measurements did not differ significantly from those obtained by direct anthropometric measurements (p > 0.05). The mean BPI was 84.89 ± 10.30 for the computerized photogrammetric measurements and 85.27 ± 10.67 for the direct anthropometric measurements. The BPI defined in this study and obtained by computerized photogrammetry is a reproducible and efficient method for measuring the eyebrow position. This journal requires that authors assign a level of evidence to each article.

  12. Computerized videodefecography versus defecography: do we need radiographs?

    Directory of Open Access Journals (Sweden)

    Carlos Walter Sobrado

    Full Text Available CONTEXT AND OBJECTIVE: Defecography has been recognized as a valuable method for evaluating patients with evacuation disorders. It consists of the use of static radiography and fluoroscopy to record different situations within anorectal dynamics. Conventionally, rectal parameters are measured using radiograms. It is rare for fluoroscopy alone to be used. Computer software has been developed with the specific aim of calculating these measurements from digitized videotaped images obtained during fluoroscopy, without the need for radiographic film, thereby developing a computerized videodefecography method. The objective was thus to compare measurements obtained via computerized videodefecography with conventional measurements and to discuss the advantages of the new method. DESIGN AND SETTING: Prospective study at the radiology service of Hospital das Clínicas, Universidade de São Paulo. METHOD: Ten consecutive normal subjects underwent videodefecography. The anorectal angle, anorectal junction, puborectalis muscle length, anal canal length and degree of anal relaxation were obtained via the conventional method (using radiography film and via computerized videodefecography using the ANGDIST software. Measurement and analysis of these parameters was performed by two independent physicians. RESULTS: Statistical analysis confirmed that the measurements obtained through direct radiography film assessment and using digital image analysis (computerized videodefecography were equivalent. CONCLUSIONS: Computerized videodefecography is equivalent to the traditional defecography examination. It has the advantage of offering reduced radiation exposure through saving on the use of radiography.

  13. Radiodiagnostic system combining scintillation GKS-2 γ camera and SAORI-01 computerized unit

    International Nuclear Information System (INIS)

    Kalashnikov, S.D.; Mishchenko, S.V.; Chuprov, P.V.

    1986-01-01

    A medical radiodiagnostic system prising the GKS-2 scintillation gamma chamber and the on-line data processing system is described. The gamma chamber consists of a detector, a two-channel control console, a microprocessor system for correction of distortions,system of photographic recording of images from an oscilloscopic display, a digital display-monitor and 6 accessiory collimators with trucks. GKS-2 has the increased spatial resolution, fast response and image homogeneity. Application of GKS-2 together with the SAORI-01 specialized on-line system,comprising the measuring computerized system, the colour-graphic display controller the polarizer photographic recording device for scanning image from the display screen and a system of base software, expands substantially diagnostic possibilities of equipment

  14. Is the ICU staff satisfied with the computerized physician order entry? A cross-sectional survey study

    Science.gov (United States)

    Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto

    2014-01-01

    Objective To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. Methods We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). Results The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, pdigitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame. PMID:24770682

  15. Development of a Computerized Adaptive Test of Children's Gross Motor Skills.

    Science.gov (United States)

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Wu, Hing-Man; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2018-03-01

    To (1) develop a computerized adaptive test for gross motor skills (GM-CAT) as a diagnostic test and an outcome measure, using the gross motor skills subscale of the Comprehensive Developmental Inventory for Infants and Toddlers (CDIIT-GM) as the candidate item bank; and (2) examine the psychometric properties and the efficiency of the GM-CAT. Retrospective study. A developmental center of a medical center. Children with and without developmental delay (N=1738). Not applicable. The CDIIT-GM contains 56 universal items on gross motor skills assessing children's antigravity control, locomotion, and body movement coordination. The item bank of the GM-CAT had 44 items that met the dichotomous Rasch model's assumptions. High Rasch person reliabilities were found for each estimated gross motor skill for the GM-CAT (Rasch person reliabilities =.940-.995, SE=.68-2.43). For children aged 6 to 71 months, the GM-CAT had good concurrent validity (r values =.97-.98), adequate to excellent diagnostic accuracy (area under receiver operating characteristics curve =.80-.98), and moderate to large responsiveness (effect size =.65-5.82). The averages of items administered for the GM-CAT were 7 to 11, depending on the age group. The results of this study support the use of the GM-CAT as a diagnostic and outcome measure to estimate children's gross motor skills in both research and clinical settings. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Test and evaluation of computerized nuclear material accounting methods. Final report

    International Nuclear Information System (INIS)

    1995-01-01

    In accordance with the definition of a Material Balance Area (MBA) as a well-defined geographical area involving an Integral operation, the building housing the BFS-1 and BFS-1 critical facilities is considered to consist of one MBA. The BFS materials are in the form of small disks clad in stainless steel and each disk with nuclear material has its own serial number. Fissile material disks in the BFS MBA can be located at three key monitoring points: BFS-1 facility, BFS-2 facility and main storage of BFS fissile materials (storage 1). When used in the BFS-1 or BFS-2 critical facilities, the fissile material disks are loaded in tubes (fuel rods) forming critical assembly cores. The following specific features of the BFS MBA should be taken into account for the purpose of computerized accounting of nuclear material: (1) very large number of nuclear material items (about 70,000 fissile material items); and (2) periodically very intensive shuffling of nuclear material items. Requirements for the computerized system are determined by basic objectives of nuclear material accounting: (1) providing accurate information on the identity and location of all items in the BFS material balance area; (2) providing accurate information on location and identity of tamper-indicating devices; (3) tracking nuclear material inventories; (4) issuing periodic reports; (5) assisting with the detection of material gains or losses; (6) providing a history of nuclear material transactions; (7) preventing unauthorized access to the system and data falsification. In August 1995, the prototype computerized accounting system was installed on the BFS facility for trial operation. Information on two nuclear material types was entered into the data base: weapon-grade plutonium metal and 36% enriched uranium dioxide. The total number of the weapon-grade plutonium disks is 12,690 and the total number of the uranium dioxide disks is 1,700

  17. Corpuscular plasma diagnostics

    International Nuclear Information System (INIS)

    Afrosimov, V.; Petrov, M.

    1984-01-01

    An elementary explanation is presented of the physical principles and important methods of corpuscular plasma diagnostics. The invaluable role of corpuscular methods for measuring the hot plasma ion component in thermonuclear facilities, especially hydrogen ions in tokamaks, is emphasized. All corpuscular methods employ analysis of fast neutral atoms and therefore the mechanism of their creation inside a hot plasma is explained first. The ammount of information obtainable from spectra of fast neutrals is discussed. Multichannel analyzers developed at the FTI A.F. Ioffe in Leningrad are described in detail. Classical passive corpuscular diagnostics are examined as are active methods using artifitial beams of hydrogen atoms. The method used for obtaining local values of ion temperature and density is explained. Corpuscular spectroscopic diagnostics and its application for measuring impurities is mentioned. (J.U.)

  18. [Cytology in uropathological diagnostics].

    Science.gov (United States)

    Gaisa, N T; Lindemann-Docter, K

    2015-11-01

    Cytology in uropathological diagnostics is mainly performed for oncological purposes. The assessment of malignancy by urothelial cell morphology is therefore decisive; however, cytology is only sensitive enough to detect high-grade tumor cells and the different low-grade tumors cannot be reliably diagnosed. Thus, the four-tier classification system of cytological findings (i.e. negative, atypical cells but significance uncertain, suspicious and positive) refers to high-grade tumor cells only. Furthermore, for valid cytological diagnostics not only the cytological specimen but also clinical information on cystoscopy findings and, if applicable, a biopsy should be evaluated together. In difficult differential diagnostic settings, e.g. differentiation between reactive versus neoplastic atypia or difficult to access lesions in the upper urinary tract, additional fluorescence in situ hybridization of cytological preparations might be helpful. At the moment there are no indications for further immunocytology or additional biomarker tests.

  19. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  20. Experience feedback of computerized controlled nuclear power plants

    International Nuclear Information System (INIS)

    Poizat, F.

    2004-01-01

    The N4 step of French PWR-type nuclear power plants is characterized by an instrumentation and control system entirely computerized (operation procedures including normal and accidental operation). Four power plants of this type (Chooz and Civaux sites) of 1450 MWe each were connected to the power grid between August 1996 and December 1999. The achievement of this program make it possible and necessary to carry out an experience feedback about the development, successes and difficulties encountered in order to draw out some lessons for future realizations. This is the aim of this article: 1 - usefulness and difficulties of such an experience feedback: evolution of instrumentation and control systems, necessary cautions; 2 - a successful computerized control: checking of systems operation, advantages, expectations; 3 - efficiency of computerized systems: demonstration of operation safety, profitability; 4 - conclusions and interrogations: system approach instead of 'micro-software' approach, commercial or 'made to measure' products, contract agreement with a supplier, when and how upgrading. (J.S.)