WorldWideScience

Sample records for computer-assisted tumor volume

  1. CT-MR image data fusion for computer assisted navigated neurosurgery of temporal bone tumors

    International Nuclear Information System (INIS)

    Nemec, Stefan Franz; Donat, Markus Alexander; Mehrain, Sheida; Friedrich, Klaus; Krestan, Christian; Matula, Christian; Imhof, Herwig; Czerny, Christian

    2007-01-01

    Purpose: To demonstrate the value of multi detector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the preoperative work up of temporal bone tumors and to present, especially, CT and MR image fusion for surgical planning and performance in computer assisted navigated neurosurgery of temporal bone tumors. Materials and methods: Fifteen patients with temporal bone tumors underwent MDCT and MRI. MDCT was performed in high-resolution bone window level setting in axial plane. The reconstructed MDCT slice thickness was 0.8 mm. MRI was performed in axial and coronal plane with T2-weighted fast spin-echo (FSE) sequences, un-enhanced and contrast-enhanced T1-weighted spin-echo (SE) sequences, and coronal T1-weighted SE sequences with fat suppression and with 3D T1-weighted gradient-echo (GE) contrast-enhanced sequences in axial plane. The 3D T1-weighted GE sequence had a slice thickness of 1 mm. Image data sets of CT and 3D T1-weighted GE sequences were merged utilizing a workstation to create CT-MR fusion images. MDCT and MR images were separately used to depict and characterize lesions. The fusion images were utilized for interventional planning and intraoperative image guidance. The intraoperative accuracy of the navigation unit was measured, defined as the deviation between the same landmark in the navigation image and the patient. Results: Tumorous lesions of bone and soft tissue were well delineated and characterized by CT and MR images. The images played a crucial role in the differentiation of benign and malignant pathologies, which consisted of 13 benign and 2 malignant tumors. The CT-MR fusion images supported the surgeon in preoperative planning and improved surgical performance. The mean intraoperative accuracy of the navigation system was 1.25 mm. Conclusion: CT and MRI are essential in the preoperative work up of temporal bone tumors. CT-MR image data fusion presents an accurate tool for planning the correct surgical procedure and is a

  2. Measurement of tumor volumes of hepatocellular carcinoma (HCC) by computed tomography (CT). Correlation with several tumor markers

    Energy Technology Data Exchange (ETDEWEB)

    Yoneshima, Manabu; Sawabu, Norio; Toya, Daishu

    1984-09-01

    Tumor volumes of HCC were measured by CT using planimeter and the clinical value of this measurement was evaluated by comparing several tumor markers. Tumor volumes measured by CT roughly agreed with those measured by angiography. In some cases, volumes from ultrasonography were smaller than those from CT and angiography. Tumor volumes measured by CT correlated significantly with the levels of ..cap alpha..-fetoprotein (AFP) but didn't relate to the presence of hepatoma specific ..gamma..-GTP isoenzyme (novel ..gamma..-GTP) nor to the values and positivities of LAI assay. In small HCCs (<=30 cm/sup 3/), the presence of novel ..gamma..-GTP and the levels of AFP were significantly lower than for larger tumors of HCC, but LAI assay wasn't lower. The non-tumorous volumes and the ratio of the non-tumorous volume to the whole liver volume didn't relate to the tests of liver function except for the presence of ascites.

  3. Reduce in Variation and Improve Efficiency of Target Volume Delineation by a Computer-Assisted System Using a Deformable Image Registration Approach

    International Nuclear Information System (INIS)

    Chao, K.S. Clifford; Bhide, Shreerang FRCR; Chen, Hansen; Asper, Joshua PAC; Bush, Steven; Franklin, Gregg; Kavadi, Vivek; Liengswangwong, Vichaivood; Gordon, William; Raben, Adam; Strasser, Jon; Koprowski, Christopher; Frank, Steven; Chronowski, Gregory; Ahamad, Anesa; Malyapa, Robert; Zhang Lifei; Dong Lei

    2007-01-01

    Purpose: To determine whether a computer-assisted target volume delineation (CAT) system using a deformable image registration approach can reduce the variation of target delineation among physicians with different head and neck (HN) IMRT experiences and reduce the time spent on the contouring process. Materials and Methods: We developed a deformable image registration method for mapping contours from a template case to a patient case with a similar tumor manifestation but different body configuration. Eight radiation oncologists with varying levels of clinical experience in HN IMRT performed target delineation on two HN cases, one with base-of-tongue (BOT) cancer and another with nasopharyngeal cancer (NPC), by first contouring from scratch and then by modifying the contours deformed by the CAT system. The gross target volumes were provided. Regions of interest for comparison included the clinical target volumes (CTVs) and normal organs. The volumetric and geometric variation of these regions of interest and the time spent on contouring were analyzed. Results: We found that the variation in delineating CTVs from scratch among the physicians was significant, and that using the CAT system reduced volumetric variation and improved geometric consistency in both BOT and NPC cases. The average timesaving when using the CAT system was 26% to 29% for more experienced physicians and 38% to 47% for the less experienced ones. Conclusions: A computer-assisted target volume delineation approach, using a deformable image-registration method with template contours, was able to reduce the variation among physicians with different experiences in HN IMRT while saving contouring time

  4. [Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering].

    Science.gov (United States)

    Günther, P; Tröger, J; Holland-Cunz, S; Waag, K L; Schenk, J P

    2006-08-01

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this.A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning.

  5. Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering

    International Nuclear Information System (INIS)

    Guenther, P.; Holland-Cunz, S.; Waag, K.L.

    2006-01-01

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this. A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning. (orig.) [de

  6. Predicting oropharyngeal tumor volume throughout the course of radiation therapy from pretreatment computed tomography data using general linear models.

    Science.gov (United States)

    Yock, Adam D; Rao, Arvind; Dong, Lei; Beadle, Beth M; Garden, Adam S; Kudchadker, Rajat J; Court, Laurence E

    2014-05-01

    The purpose of this work was to develop and evaluate the accuracy of several predictive models of variation in tumor volume throughout the course of radiation therapy. Nineteen patients with oropharyngeal cancers were imaged daily with CT-on-rails for image-guided alignment per an institutional protocol. The daily volumes of 35 tumors in these 19 patients were determined and used to generate (1) a linear model in which tumor volume changed at a constant rate, (2) a general linear model that utilized the power fit relationship between the daily and initial tumor volumes, and (3) a functional general linear model that identified and exploited the primary modes of variation between time series describing the changing tumor volumes. Primary and nodal tumor volumes were examined separately. The accuracy of these models in predicting daily tumor volumes were compared with those of static and linear reference models using leave-one-out cross-validation. In predicting the daily volume of primary tumors, the general linear model and the functional general linear model were more accurate than the static reference model by 9.9% (range: -11.6%-23.8%) and 14.6% (range: -7.3%-27.5%), respectively, and were more accurate than the linear reference model by 14.2% (range: -6.8%-40.3%) and 13.1% (range: -1.5%-52.5%), respectively. In predicting the daily volume of nodal tumors, only the 14.4% (range: -11.1%-20.5%) improvement in accuracy of the functional general linear model compared to the static reference model was statistically significant. A general linear model and a functional general linear model trained on data from a small population of patients can predict the primary tumor volume throughout the course of radiation therapy with greater accuracy than standard reference models. These more accurate models may increase the prognostic value of information about the tumor garnered from pretreatment computed tomography images and facilitate improved treatment management.

  7. Predicting oropharyngeal tumor volume throughout the course of radiation therapy from pretreatment computed tomography data using general linear models

    International Nuclear Information System (INIS)

    Yock, Adam D.; Kudchadker, Rajat J.; Rao, Arvind; Dong, Lei; Beadle, Beth M.; Garden, Adam S.; Court, Laurence E.

    2014-01-01

    Purpose: The purpose of this work was to develop and evaluate the accuracy of several predictive models of variation in tumor volume throughout the course of radiation therapy. Methods: Nineteen patients with oropharyngeal cancers were imaged daily with CT-on-rails for image-guided alignment per an institutional protocol. The daily volumes of 35 tumors in these 19 patients were determined and used to generate (1) a linear model in which tumor volume changed at a constant rate, (2) a general linear model that utilized the power fit relationship between the daily and initial tumor volumes, and (3) a functional general linear model that identified and exploited the primary modes of variation between time series describing the changing tumor volumes. Primary and nodal tumor volumes were examined separately. The accuracy of these models in predicting daily tumor volumes were compared with those of static and linear reference models using leave-one-out cross-validation. Results: In predicting the daily volume of primary tumors, the general linear model and the functional general linear model were more accurate than the static reference model by 9.9% (range: −11.6%–23.8%) and 14.6% (range: −7.3%–27.5%), respectively, and were more accurate than the linear reference model by 14.2% (range: −6.8%–40.3%) and 13.1% (range: −1.5%–52.5%), respectively. In predicting the daily volume of nodal tumors, only the 14.4% (range: −11.1%–20.5%) improvement in accuracy of the functional general linear model compared to the static reference model was statistically significant. Conclusions: A general linear model and a functional general linear model trained on data from a small population of patients can predict the primary tumor volume throughout the course of radiation therapy with greater accuracy than standard reference models. These more accurate models may increase the prognostic value of information about the tumor garnered from pretreatment computed tomography

  8. Anatomy, gross tumor volume and clinical target volume: tumors of the lower third of the esophagus and the gastro esophageal junction

    International Nuclear Information System (INIS)

    Calais, G.; Asquier, E.; Louisot, P.

    2001-01-01

    The esophagus is divided into four regions: cervical esophagus, intrathoracic esophagus with upper, mid and lower thoracic portion. Cancer may occur on each of these regions. Computed tomography of the thorax and superior abdomen and endoscopic ultrasound are necessary for reliable staging. CT simulation allows accurate definition of tumor volume. GTV includes tumor volume and regional lymph nodes. CTV encompasses GTV plus safety margin and lymph nodes areas considered to harbor potential microscopic disease. The extent of prophylactic lymph node irradiation depends on the anatomic location of the primary tumor. (author)

  9. Medical image computing and computer-assisted intervention - MICCAI 2005. Proceedings; Pt. 1

    International Nuclear Information System (INIS)

    Duncan, J.S.; Gerig, G.

    2005-01-01

    The two-volume set LNCS 3749 and LNCS 3750 constitutes the refereed proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2005, held in Palm Springs, CA, USA, in October 2005. Based on rigorous peer reviews the program committee selected 237 carefully revised full papers from 632 submissions for presentation in two volumes. The first volume includes all the contributions related to image analysis and validation, vascular image segmentation, image registration, diffusion tensor image analysis, image segmentation and analysis, clinical applications - validation, imaging systems - visualization, computer assisted diagnosis, cellular and molecular image analysis, physically-based modeling, robotics and intervention, medical image computing for clinical applications, and biological imaging - simulation and modeling. The second volume collects the papers related to robotics, image-guided surgery and interventions, image registration, medical image computing, structural and functional brain analysis, model-based image analysis, image-guided intervention: simulation, modeling and display, and image segmentation and analysis. (orig.)

  10. Medical image computing and computer-assisted intervention - MICCAI 2005. Proceedings; Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.S. [Yale Univ., New Haven, CT (United States). Dept. of Biomedical Engineering and Diagnostic Radiology; Gerig, G. (eds.) [North Carolina Univ., Chapel Hill (United States). Dept. of Computer Science

    2005-07-01

    The two-volume set LNCS 3749 and LNCS 3750 constitutes the refereed proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2005, held in Palm Springs, CA, USA, in October 2005. Based on rigorous peer reviews the program committee selected 237 carefully revised full papers from 632 submissions for presentation in two volumes. The first volume includes all the contributions related to image analysis and validation, vascular image segmentation, image registration, diffusion tensor image analysis, image segmentation and analysis, clinical applications - validation, imaging systems - visualization, computer assisted diagnosis, cellular and molecular image analysis, physically-based modeling, robotics and intervention, medical image computing for clinical applications, and biological imaging - simulation and modeling. The second volume collects the papers related to robotics, image-guided surgery and interventions, image registration, medical image computing, structural and functional brain analysis, model-based image analysis, image-guided intervention: simulation, modeling and display, and image segmentation and analysis. (orig.)

  11. Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Yong; Lim, Sang Wook; Ma, Sun Young; Yu, Je Sang [Dept. of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan (Korea, Republic of)

    2017-09-15

    To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%–60%, 30%–70%, and 0%–90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. As narrow as possible duty cycle such as 40%–60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.

  12. Robot-assisted partial nephrectomy for hilar tumors: perioperative outcomes.

    Science.gov (United States)

    Eyraud, Rémi; Long, Jean-Alexandre; Snow-Lisy, Devon; Autorino, Riccardo; Hillyer, Shahab; Klink, Joseph; Rizkala, Emad; Stein, Robert J; Kaouk, Jihad H; Haber, Georges-Pascal

    2013-06-01

    To compare perioperative outcomes of robot-assisted partial nephrectomy (RAPN) for hilar vs nonhilar tumors. The study retrospectively reviewed 364 patients with available computed tomography scans undergoing RAPN. Demographic data and perioperative outcomes results were compared between the hilar (group 1, n = 70) and nonhilar tumors (group 2, n = 294). Multivariate analysis was used to identify predictors of warm ischemia time (WIT), estimated blood loss (EBL), major perioperative complications, and postoperative renal function. There were no differences with respect to demographic variables. Hilar tumors had higher RENAL (radius, exophytic/endophytic properties of the tumor, nearness of tumor deepest portion to the collecting system or sinus, anterior/posterior descriptor and the location relative to polar lines) scores (P hilar tumors were associated with greater operative time (210 vs 180 minutes, P hilar vs nonhilar patients on postoperative day 3 (70.12 vs 74.71 mL/min/1.73 m(2), P = .31) or at last follow-up (72.62 vs 75.78 mL/min/1.73 m(2), P = .40), respectively. Multivariate analysis found hilar location was independently associated with increased WIT without significant changes in EBL, major complications, or postoperative renal function. RAPN represents a safe and effective procedure for hilar tumors. Hilar location for patients undergoing RAPN in a high-volume institution seems not be associated with an increased risk of transfusions, major complications, or decline of early postoperative renal function. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Computer-assisted planning and dosimetry for radiation treatment of head and neck cancer in Cameroon

    International Nuclear Information System (INIS)

    Yomi, J.; Ngniah, A.; Kingue, S.; Muna, W.F.T.; Durosinmi-Etti, F.A.

    1995-01-01

    This evaluation was part of a multicenter, multinational study sponsored by the International Agency for Atomic Energy (Vienna) to investigate a simple, reliable computer-assisted planning and dosimetry system for radiation treatment of head and neck cancers in developing countries. Over a 13-month period (April 1992-April 1993), 120 patients with histologically-proven head or neck cancer were included in the evaluation. In each patient, planning and dosimetry were done both manually and using the computer-assisted system. The manual and computerized systems were compared on the basis of accuracy of determination of the outer contour, target volume, and critical organs; volume inequality resolution; structure heterogeneity correction; selection of the number, angle, and size of beams; treatment time calculation; availability of dosimetry predictions; and duration and cost of the procedure. Results demonstrated that the computer-assisted procedure was superior over the manual procedure, despite less than optimal software. The accuracy provided by the completely computerized procedure is indispensable for Level II radiation therapy, which is particularly useful in tumors of the sensitive, complex structures in the head and neck. (authors). 7 refs., 3 tabs

  14. Brain tumor locating in 3D MR volume using symmetry

    Science.gov (United States)

    Dvorak, Pavel; Bartusek, Karel

    2014-03-01

    This work deals with the automatic determination of a brain tumor location in 3D magnetic resonance volumes. The aim of this work is not the precise segmentation of the tumor and its parts but only the detection of its location. This work is the first step in the tumor segmentation process, an important topic in neuro-image processing. The algorithm expects 3D magnetic resonance volumes of brain containing a tumor. The detection is based on locating the area that breaks the left-right symmetry of the brain. This is done by multi-resolution comparing of corresponding regions in left and right hemisphere. The output of the computation is the probabilistic map of the tumor location. The created algorithm was tested on 80 volumes from publicly available BRATS databases containing 3D brain volumes afflicted by a brain tumor. These pathological structures had various sizes and shapes and were located in various parts of the brain. The locating performance of the algorithm was 85% for T1-weighted volumes, 91% for T1-weighted contrast enhanced volumes, 96% for FLAIR and T2-wieghted volumes and 95% for their combinations.

  15. Assessing Respiration-Induced Tumor Motion and Internal Target Volume Using Four-Dimensional Computed Tomography for Radiotherapy of Lung Cancer

    International Nuclear Information System (INIS)

    Liu, H. Helen; Balter, Peter; Tutt, Teresa; Choi, Bum; Zhang, Joy; Wang, Catherine; Chi, Melinda; Luo Dershan; Pan Tinsu; Hunjan, Sandeep; Starkschall, George; Rosen, Isaac; Prado, Karl; Liao Zhongxing; Chang, Joe; Komaki, Ritsuko; Cox, James D.; Mohan, Radhe; Dong Lei

    2007-01-01

    Purpose: To assess three-dimensional tumor motion caused by respiration and internal target volume (ITV) for radiotherapy of lung cancer. Methods and Materials: Respiration-induced tumor motion was analyzed for 166 tumors from 152 lung cancer patients, 57.2% of whom had Stage III or IV non-small-cell lung cancer. All patients underwent four-dimensional computed tomography (4DCT) during normal breathing before treatment. The expiratory phase of 4DCT images was used as the reference set to delineate gross tumor volume (GTV). Gross tumor volumes on other respiratory phases and resulting ITVs were determined using rigid-body registration of 4DCT images. The association of GTV motion with various clinical and anatomic factors was analyzed statistically. Results: The proportions of tumors that moved >0.5 cm along the superior-inferior (SI), lateral, and anterior-posterior (AP) axes during normal breathing were 39.2%, 1.8%, and 5.4%, respectively. For 95% of the tumors, the magnitude of motion was less than 1.34 cm, 0.40 cm, and 0.59 cm along the SI, lateral, and AP directions. The principal component of tumor motion was in the SI direction, with only 10.8% of tumors moving >1.0 cm. The tumor motion was found to be associated with diaphragm motion, the SI tumor location in the lung, size of the GTV, and disease T stage. Conclusions: Lung tumor motion is primarily driven by diaphragm motion. The motion of locally advanced lung tumors is unlikely to exceed 1.0 cm during quiet normal breathing except for small lesions located in the lower half of the lung

  16. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H

    2015-01-01

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology

  17. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H [The University of Chicago, Chicago, IL (United States)

    2015-06-15

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology.

  18. Correlation between metabolic tumor volume and pathologic tumor volume in squamous cell carcinoma of the oral cavity

    International Nuclear Information System (INIS)

    Murphy, James D.; Chisholm, Karen M.; Daly, Megan E.; Wiegner, Ellen A.; Truong, Daniel; Iagaru, Andrei; Maxim, Peter G.; Loo, Billy W.; Graves, Edward E.; Kaplan, Michael J.; Kong, Christina; Le, Quynh-Thu

    2011-01-01

    Purpose: To explore the relationship between pathologic tumor volume and volume estimated from different tumor segmentation techniques on 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in oral cavity cancer. Materials and methods: Twenty-three patients with squamous cell carcinoma of the oral tongue had PET–CT scans before definitive surgery. Pathologic tumor volume was estimated from surgical specimens. Metabolic tumor volume (MTV) was defined from PET–CT scans as the volume of tumor above a given SUV threshold. Multiple SUV thresholds were explored including absolute SUV thresholds, relative SUV thresholds, and gradient-based techniques. Results: Multiple MTV’s were associated with pathologic tumor volume; however the correlation was poor (R 2 range 0.29–0.58). The ideal SUV threshold, defined as the SUV that generates an MTV equal to pathologic tumor volume, was independently associated with maximum SUV (p = 0.0005) and tumor grade (p = 0.024). MTV defined as a function of maximum SUV and tumor grade improved the prediction of pathologic tumor volume (R 2 = 0.63). Conclusions: Common SUV thresholds fail to predict pathologic tumor volume in head and neck cancer. The optimal technique that allows for integration of PET–CT with radiation treatment planning remains to be defined. Future investigation should incorporate biomarkers such as tumor grade into definitions of MTV.

  19. Viable tumor volume: Volume of interest within segmented metastatic lesions, a pilot study of proposed computed tomography response criteria for urothelial cancer

    International Nuclear Information System (INIS)

    Folio, Les Roger; Turkbey, Evrim B.; Steinberg, Seth M.; Apolo, Andrea B.

    2015-01-01

    Highlights: • It is clear that 2D axial measurements are incomplete assessments in metastatic disease; especially in light of evolving antiangiogenic therapies that can result in tumor necrosis. • Our pilot study demonstrates that taking volumetric density into account can better predict overall survival when compared to RECIST, volumetric size, MASS and Choi. • Although volumetric segmentation and further density analysis may not yet be feasible within routine workflows, the authors believe that technology advances may soon make this possible. - Abstract: Objectives: To evaluate the ability of new computed tomography (CT) response criteria for solid tumors such as urothelial cancer (VTV; viable tumor volume) to predict overall survival (OS) in patients with metastatic bladder cancer treated with cabozantinib. Materials and methods: We compared the relative capabilities of VTV, RECIST, MASS (morphology, attenuation, size, and structure), and Choi criteria, as well as volume measurements, to predict OS using serial follow-up contrast-enhanced CT exams in patients with metastatic urothelial carcinoma. Kaplan–Meier curves and 2-tailed log-rank tests compared OS based on early RECIST 1.1 response against each of the other criteria. A Cox proportional hazards model assessed response at follow-up exams as a time-varying covariate for OS. Results: We assessed 141 lesions in 55CT scans from 17 patients with urothelial metastasis, comparing VTV, RECIST, MASS, and Choi criteria, and volumetric measurements, for response assessment. Median follow-up was 4.5 months, range was 2–14 months. Only the VTV criteria demonstrated a statistical association with OS (p = 0.019; median OS 9.7 vs. 3.5 months). Conclusion: This pilot study suggests that VTV is a promising tool for assessing tumor response and predicting OS, using criteria that incorporate tumor volume and density in patients receiving antiangiogenic therapy for urothelial cancer. Larger studies are warranted to

  20. A comparison of perfusion computed tomography and contrast enhanced computed tomography on radiation target volume delineation using rabbit VX2 brain tumor model

    International Nuclear Information System (INIS)

    Sun Changjin; Luo Yunxiu; Yu Jinming; Lu Haibo; Li Chao; Zhang Dekang; Huang Jianming; Wang Jie; Lang Jinyi

    2010-01-01

    Objective: To compare the accuracy of blood volume perfusion imaging (perfusion CT)with contrast enhanced 64-slice spiral computed tomography (CECT) in the evaluation of gross tumor volume (GTV) and clinical target volume (CTV) using rabbits with VX2 brain tumor. Methods: Perfusion CT and CECT were performed in 20 rabbits with VX2 brain tumor. The GTV and CTV calculated with the maximal and minimal diameter of each tumor in the blood volume (BV) maps and CECT were measured and compared to those in pathological specimens. Results: The mean value of the maximal and minimal diameter of GTV was (8.19 ± 2.29) mm and (4.83 ± 1.31) mm in pathological specimens, (11.98 ±3.29) mm and (7.03±1.82) mm in BV maps, while (6.36±3.85) mm and (3.17±1.93) mm in CECT images, which were significantly different (pathological specimen vs. BV map, t = 7.17, P =0.000;pathological specimen vs. CECT, t = 8.37, P = 0.000, respectively). The mean value of the maximal and minimal diameter of CTV in pathologic specimens was (12.87 ± 3.74) mm and (7.71 ± 2.15) mm, which was significantly different from that of GTV and CTV in CECT (t = - 3. 18, P = 0. 005 and t = - 4.24, P =0.000; t= -11.59,P=0.000 and t= -9.39, P=0.000), while similar with that of GTV in BV maps (t = - 1.95,P = 0. 067; t = - 2. 06, P = 0. 054). For CECT, the margin from GTV to CTV was 81.83% ±40.33% for the maximal diameter and 276.73% ± 131.46% for the minimal. While for BV maps, the margin was 7.93% ± 17. 84% and 12.52% ± 27. 83%, which was significant different from that for CECT images (t=7.36, P=0. 000 and t= -8.78, P=0.000). Conclusions: Compared with CECT, the BV map from 64-slice spiral CT perfusion imaging might have higher accuracy in target volume delineation for brain tumor. (authors)

  1. Oral and maxillofacial surgery with computer-assisted navigation system.

    Science.gov (United States)

    Kawachi, Homare; Kawachi, Yasuyuki; Ikeda, Chihaya; Takagi, Ryo; Katakura, Akira; Shibahara, Takahiko

    2010-01-01

    Intraoperative computer-assisted navigation has gained acceptance in maxillofacial surgery with applications in an increasing number of indications. We adapted a commercially available wireless passive marker system which allows calibration and tracking of virtually every instrument in maxillofacial surgery. Virtual computer-generated anatomical structures are displayed intraoperatively in a semi-immersive head-up display. Continuous observation of the operating field facilitated by computer assistance enables surgical navigation in accordance with the physician's preoperative plans. This case report documents the potential for augmented visualization concepts in surgical resection of tumors in the oral and maxillofacial region. We report a case of T3N2bM0 carcinoma of the maxillary gingival which was surgically resected with the assistance of the Stryker Navigation Cart System. This system was found to be useful in assisting preoperative planning and intraoperative monitoring.

  2. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  3. Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Trakul, Nicholas; Chang, Christine N.; Harris, Jeremy [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Chapman, Christopher [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of Michigan School of Medicine, Ann Arbor, MI (United States); Rao, Aarti [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of California, Davis, School of Medicine, Davis, CA (United States); Shen, John [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of California, Irvine, School of Medicine, Irvine, CA (United States); Quinlan-Davidson, Sean [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Department of Radiation Oncology, McMaster University, Juravinski Cancer Centre, Hamilton, Ontario (Canada); Filion, Edith J. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Departement de Medecine, Service de Radio-Oncologie, Centre Hospitalier de l' Universite de Montreal, Montreal, Quebec (Canada); Wakelee, Heather A.; Colevas, A. Dimitrios [Department of Medicine, Division of Oncology, Stanford University School of Medicine, Stanford, CA (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, CA (United States); Whyte, Richard I. [Department of Cardiothoracic Surgery, Division of General Thoracic Surgery, Stanford University School of Medicine, Stanford, CA (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, CA (United States); and others

    2012-09-01

    Purpose: Current stereotactic ablative radiotherapy (SABR) protocols for lung tumors prescribe a uniform dose regimen irrespective of tumor size. We report the outcomes of a lung tumor volume-adapted SABR dosing strategy. Methods and Materials: We retrospectively reviewed the outcomes in 111 patients with a total of 138 primary or metastatic lung tumors treated by SABR, including local control, regional control, distant metastasis, overall survival, and treatment toxicity. We also performed subset analysis on 83 patients with 97 tumors treated with a volume-adapted dosing strategy in which small tumors (gross tumor volume <12 mL) received single-fraction regimens with biologically effective doses (BED) <100 Gy (total dose, 18-25 Gy) (Group 1), and larger tumors (gross tumor volume {>=}12 mL) received multifraction regimens with BED {>=}100 Gy (total dose, 50-60 Gy in three to four fractions) (Group 2). Results: The median follow-up time was 13.5 months. Local control for Groups 1 and 2 was 91.4% and 92.5%, respectively (p = 0.24) at 12 months. For primary lung tumors only (excluding metastases), local control was 92.6% and 91.7%, respectively (p = 0.58). Regional control, freedom from distant metastasis, and overall survival did not differ significantly between Groups 1 and 2. Rates of radiation pneumonitis, chest wall toxicity, and esophagitis were low in both groups, but all Grade 3 toxicities developed in Group 2 (p = 0.02). Conclusion: A volume-adapted dosing approach for SABR of lung tumors seems to provide excellent local control for both small- and large-volume tumors and may reduce toxicity.

  4. Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung Tumors

    International Nuclear Information System (INIS)

    Trakul, Nicholas; Chang, Christine N.; Harris, Jeremy; Chapman, Christopher; Rao, Aarti; Shen, John; Quinlan-Davidson, Sean; Filion, Edith J.; Wakelee, Heather A.; Colevas, A. Dimitrios; Whyte, Richard I.

    2012-01-01

    Purpose: Current stereotactic ablative radiotherapy (SABR) protocols for lung tumors prescribe a uniform dose regimen irrespective of tumor size. We report the outcomes of a lung tumor volume-adapted SABR dosing strategy. Methods and Materials: We retrospectively reviewed the outcomes in 111 patients with a total of 138 primary or metastatic lung tumors treated by SABR, including local control, regional control, distant metastasis, overall survival, and treatment toxicity. We also performed subset analysis on 83 patients with 97 tumors treated with a volume-adapted dosing strategy in which small tumors (gross tumor volume <12 mL) received single-fraction regimens with biologically effective doses (BED) <100 Gy (total dose, 18–25 Gy) (Group 1), and larger tumors (gross tumor volume ≥12 mL) received multifraction regimens with BED ≥100 Gy (total dose, 50–60 Gy in three to four fractions) (Group 2). Results: The median follow-up time was 13.5 months. Local control for Groups 1 and 2 was 91.4% and 92.5%, respectively (p = 0.24) at 12 months. For primary lung tumors only (excluding metastases), local control was 92.6% and 91.7%, respectively (p = 0.58). Regional control, freedom from distant metastasis, and overall survival did not differ significantly between Groups 1 and 2. Rates of radiation pneumonitis, chest wall toxicity, and esophagitis were low in both groups, but all Grade 3 toxicities developed in Group 2 (p = 0.02). Conclusion: A volume-adapted dosing approach for SABR of lung tumors seems to provide excellent local control for both small- and large-volume tumors and may reduce toxicity.

  5. Assessment of interpatient heterogeneity in tumor radiosensitivity for nonsmall cell lung cancer using tumor-volume variation data

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, Alexei V., E-mail: chvetsov2@gmail.com; Schwartz, Jeffrey L.; Mayr, Nina [Department of Radiation Oncology, University of Washington, 1959 NE Pacific Street, Seattle, Washington 98195-6043 (United States); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, 790 Commissioners Road East, London, Ontario 46A 4L6 (Canada)

    2014-06-15

    Purpose: In our previous work, the authors showed that a distribution of cell surviving fractionsS{sub 2} in a heterogeneous group of patients could be derived from tumor-volume variation curves during radiotherapy for head and neck cancer. In this research study, the authors show that this algorithm can be applied to other tumors, specifically in nonsmall cell lung cancer. This new application includes larger patient volumes and includes comparison of data sets obtained at independent institutions. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage computed tomography. Statistical distributions of cell surviving fractionsS{sub 2} and clearance half-lives of lethally damaged cells T{sub 1/2} have been reconstructed in each patient group by using a version of the two-level cell population model of tumor response and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Nonsmall cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractionsS{sub 2} for nonsmall cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sub 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Conclusions: The data obtained

  6. Iterative volume morphing and learning for mobile tumor based on 4DCT.

    Science.gov (United States)

    Mao, Songan; Wu, Huanmei; Sandison, George; Fang, Shiaofen

    2017-02-21

    During image-guided cancer radiation treatment, three-dimensional (3D) tumor volumetric information is important for treatment success. However, it is typically not feasible to image a patient's 3D tumor continuously in real time during treatment due to concern over excessive patient radiation dose. We present a new iterative morphing algorithm to predict the real-time 3D tumor volume based on time-resolved computed tomography (4DCT) acquired before treatment. An offline iterative learning process has been designed to derive a target volumetric deformation function from one breathing phase to another. Real-time volumetric prediction is performed to derive the target 3D volume during treatment delivery. The proposed iterative deformable approach for tumor volume morphing and prediction based on 4DCT is innovative because it makes three major contributions: (1) a novel approach to landmark selection on 3D tumor surfaces using a minimum bounding box; (2) an iterative morphing algorithm to generate the 3D tumor volume using mapped landmarks; and (3) an online tumor volume prediction strategy based on previously trained deformation functions utilizing 4DCT. The experimental performance showed that the maximum morphing deviations are 0.27% and 1.25% for original patient data and artificially generated data, which is promising. This newly developed algorithm and implementation will have important applications for treatment planning, dose calculation and treatment validation in cancer radiation treatment.

  7. Comparing renal function preservation after laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for clinical T1a renal tumor: using a 3D parenchyma measurement system.

    Science.gov (United States)

    Zhu, Liangsong; Wu, Guangyu; Huang, Jiwei; Wang, Jianfeng; Zhang, Ruiyun; Kong, Wen; Xue, Wei; Huang, Yiran; Chen, Yonghui; Zhang, Jin

    2017-05-01

    To compare the renal function preservation between laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy. Data were analyzed from 246 patients who underwent laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for solitary cT1a renal cell carcinoma from January 2013 to July 2015. To reduce the intergroup difference, we used a 1:1 propensity matching analysis. The functional renal parenchyma volume preservation were measured preoperative and 12 months after surgery. The total renal function recovery and spilt GFR was compared. Multivariable logistic analysis was used for predictive factors for renal function decline. After 1:1 propensity matching, each group including 100 patients. Patients in the laparoscopic radio frequency ablation assisted tumor enucleation had a smaller decrease in estimate glomerular filtration rate at 1 day (-7.88 vs -20.01%, p renal parenchyma volume preservation (89.19 vs 84.27%, p renal parenchyma volume preservation, warm ischemia time and baseline renal function were the important independent factors in determining long-term functional recovery. The laparoscopic radio frequency ablation assisted tumor enucleation technology has unique advantage and potential in preserving renal parenchyma without ischemia damage compared to conventional laparoscopic partial nephrectomy, and had a better outcome, thus we recommend this technique in selected T1a patients.

  8. [Application of three-dimensional computer graphics in oncology].

    Science.gov (United States)

    Joyeux, H; Jaeger, M; Briand, D; Servois, V; Masson, B; Borianne, P; de Reffye, P

    1996-01-01

    Accurate 3D tumoral volume evaluation is now possible through the combined use and progress of computer graphics technics (3D reconstruction and visualization) and medical imagery (helicoidal TDM scanner). Specific organ and pathology oriented softwares can help answer rapidly to problems posed by oncologic praticians. A new decision support for diagnosis, therapy and follow-up is emerging. First results in liver tumors and hepatic regeneration macroscopic biometrics are presented. Tumoral or organ volumic index will be usable in the follow-up. TNM staging, external conformal radiotherapy for prostatic or brain tumors, drugs cytolytic effects evaluation will take great advantage of these technologies. 3D visualization and matching CT and MRI imagery can help computed assisted surgery.

  9. Three-Dimensional Segmentation of the Tumor in Computed Tomographic Images of Neuroblastoma

    OpenAIRE

    Deglint, Hanford J.; Rangayyan, Rangaraj M.; Ayres, Fábio J.; Boag, Graham S.; Zuffo, Marcelo K.

    2006-01-01

    Segmentation of the tumor in neuroblastoma is complicated by the fact that the mass is almost always heterogeneous in nature; furthermore, viable tumor, necrosis, and normal tissue are often intermixed. Tumor definition and diagnosis require the analysis of the spatial distribution and Hounsfield unit (HU) values of voxels in computed tomography (CT) images, coupled with a knowledge of normal anatomy. Segmentation and analysis of the tissue composition of the tumor can assist in quantitative ...

  10. ULTRASOUND AND COMPUTED TOMOGRAPHIC DIAGNOSIS OF OPTIC NERVE TUMORS

    Directory of Open Access Journals (Sweden)

    S. V. Saakyan

    2012-01-01

    Full Text Available A comprehensive examination was made in 93 patients, including 18 children, with tumors of the optic nerve (ON. Duplex ultrasound scanning was performed in 39 patients, of them there were 11 patients with ON gliomas and 28 with ON meningiomas. The specific computed tomographic and echographic signs of ON glioma and meningiomas were detected. The studies have shown that duplex ultrasound scanning and structural computed tomography of orbital sockets are highly informative complementary imaging procedures for ON tumors, which permits one to make their correct diagnosis, to specify surgical volume, and to plan adequate treatment.

  11. Assessment of the ABC/2 Method of Epidural Hematoma Volume Measurement as Compared to Computer-Assisted Planimetric Analysis.

    Science.gov (United States)

    Hu, Ting-Ting; Yan, Ling; Yan, Peng-Fei; Wang, Xuan; Yue, Ge-Fen

    2016-01-01

    Epidural hematoma volume (EDHV) is an independent predictor of prognosis in patients with epidural hematoma (EDH) and plays a central role in treatment decision making. This study's objective was to determine the accuracy and reliability of the widely used volume measurement method ABC/2 in estimating EDHV by comparing it to the computer-assisted planimetric method. A data set of computerized tomography (CT) scans of 35 patients with EDH was evaluated to determine the accuracy of ABC/2 method, using computer-assisted planimetric technique to establish the reference criterion of EDHV for each patient. Another data set was constructed by randomly selecting 5 patients then replicating each case twice to yield 15 patients. Intra- and interobserver reliability were evaluated by asking four observers to independently estimate EDHV for the latter data set using the ABC/2 method. Estimation of EDHV using the ABC/2 method showed high intra- and interobserver reliability (intra-class correlation coefficient = .99). These estimates were closely correlated with planimetric measures (r = .99). But the ABC/2 method generally overestimated EDHV, especially in the nonellipsoid-like group. The difference between the ABC/2 measures and planimetric measures was statistically significant (p ABC/2 method could be used for EDHV measurement, which would contribute to treatment decision making as well as clinical outcome prediction. However, clinicians should be aware that the ABC/2 method results in a general volume overestimation. Future studies focusing on justification of the technique to improve its accuracy would be of practical value. © The Author(s) 2015.

  12. Computer assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.; Jaffe, C.C.; Felix, R.

    1993-01-01

    The proceedings of the CAR'93 symposium present the 126 oral papers and the 58 posters contributed to the four Technical Sessions entitled: (1) Image Management, (2) Medical Workstations, (3) Digital Image Generation - DIG, and (4) Application Systems - AS. Topics discussed in Session (1) are: picture archiving and communication systems, teleradiology, hospital information systems and radiological information systems, technology assessment and implications, standards, and data bases. Session (2) deals with computer vision, computer graphics, design and application, man computer interaction. Session (3) goes into the details of the diagnostic examination methods such as digital radiography, MRI, CT, nuclear medicine, ultrasound, digital angiography, and multimodality imaging. Session (4) is devoted to computer-assisted techniques, as there are: computer assisted radiological diagnosis, knowledge based systems, computer assisted radiation therapy and computer assisted surgical planning. (UWA). 266 figs [de

  13. Tumor-Volume Simulation During Radiotherapy for Head-and-Neck Cancer Using a Four-Level Cell Population Model

    International Nuclear Information System (INIS)

    Chvetsov, Alexei V.; Dong Lei; Palta, Jantinder R.; Amdur, Robert J.

    2009-01-01

    Purpose: To develop a fast computational radiobiologic model for quantitative analysis of tumor volume during fractionated radiotherapy. The tumor-volume model can be useful for optimizing image-guidance protocols and four-dimensional treatment simulations in proton therapy that is highly sensitive to physiologic changes. Methods: The analysis is performed using two approximations: (1) tumor volume is a linear function of total cell number and (2) tumor-cell population is separated into four subpopulations: oxygenated viable cells, oxygenated lethally damaged cells, hypoxic viable cells, and hypoxic lethally damaged cells. An exponential decay model is used for disintegration and removal of oxygenated lethally damaged cells from the tumor. Results: We tested our model on daily volumetric imaging data available for 14 head-and-neck cancer patients treated with an integrated computed tomography/linear accelerator system. A simulation based on the averaged values of radiobiologic parameters was able to describe eight cases during the entire treatment and four cases partially (50% of treatment time) with a maximum 20% error. The largest discrepancies between the model and clinical data were obtained for small tumors, which may be explained by larger errors in the manual tumor volume delineation procedure. Conclusions: Our results indicate that the change in gross tumor volume for head-and-neck cancer can be adequately described by a relatively simple radiobiologic model. In future research, we propose to study the variation of model parameters by fitting to clinical data for a cohort of patients with head-and-neck cancer and other tumors. The potential impact of other processes, like concurrent chemotherapy, on tumor volume should be evaluated.

  14. The Impact of Positron Emission Tomography/Computed Tomography in Edge Delineation of Gross Tumor Volume for Head and Neck Cancers

    International Nuclear Information System (INIS)

    Ashamalla, Hani; Guirgius, Adel; Bieniek, Ewa; Rafla, Sameer; Evola, Alex; Goswami, Ganesh; Oldroyd, Randall; Mokhtar, Bahaa; Parikh, Kapila

    2007-01-01

    Purpose: To study anatomic biologic contouring (ABC), using a previously described distinct halo, to unify volume contouring methods in treatment planning for head and neck cancers. Methods and Materials: Twenty-five patients with head and neck cancer at various sites were planned for radiation therapy using positron emission tomography/computed tomography (PET/CT). The ABC halo was used in all PET/CT scans to contour the gross tumor volume (GTV) edge. The CT-based GTV (GTV-CT) and PET/CT-based GTV (GTV-ABC) were contoured by two independent radiation oncologists. Results: The ABC halo was observed in all patients studied. The halo had a standard unit value of 2.19 ± 0.28. The mean halo thickness was 2.02 ± 0.21 mm. Significant volume modification (≥25%) was seen in 17 of 25 patients (68%) after implementation of GTV-ABC. Concordance among observers was increased with the use of the halo as a guide for GTV determination: 6 patients (24%) had a ≤10% volume discrepancy with CT alone, compared with 22 (88%) with PET/CT (p 3 in CT-based planning to 7.2 cm 3 in PET/CT-based planning (p < 0.001). Conclusions: Using the 'anatomic biologic halo' to contour GTV in PET/CT improves consistency among observers. The distinctive appearance of the described halo and its presence in all of the studied tumors make it attractive for GTV contouring in head and neck tumors. Additional studies are needed to confirm the correlation of the halo with presence of malignant cells

  15. Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

    Science.gov (United States)

    Karki, Kishor; Saraiya, Siddharth; Hugo, Geoffrey D; Mukhopadhyay, Nitai; Jan, Nuzhat; Schuster, Jessica; Schutzer, Matthew; Fahrner, Lester; Groves, Robert; Olsen, Kathryn M; Ford, John C; Weiss, Elisabeth

    2017-09-01

    To investigate interobserver delineation variability for gross tumor volumes of primary lung tumors and associated pathologic lymph nodes using magnetic resonance imaging (MRI), and to compare the results with computed tomography (CT) alone- and positron emission tomography (PET)-CT-based delineations. Seven physicians delineated the tumor volumes of 10 patients for the following scenarios: (1) CT only, (2) PET-CT fusion images registered to CT ("clinical standard"), and (3) postcontrast T1-weighted MRI registered with diffusion-weighted MRI. To compute interobserver variability, the median surface was generated from all observers' contours and used as the reference surface. A physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest wall) on the median surface. Contoured volumes and bidirectional local distances between individual observers' contours and the reference contour were analyzed. Computed tomography- and MRI-based tumor volumes normalized relative to PET-CT-based volumes were 1.62 ± 0.76 (mean ± standard deviation) and 1.38 ± 0.44, respectively. Volume differences between the imaging modalities were not significant. Between observers, the mean normalized volumes per patient averaged over all patients varied significantly by a factor of 1.6 (MRI) and 2.0 (CT and PET-CT) (P=4.10 × 10 -5 to 3.82 × 10 -9 ). The tumor-atelectasis interface had a significantly higher variability than other interfaces for all modalities combined (P=.0006). The interfaces with the smallest uncertainties were tumor-lung (on CT) and tumor-mediastinum (on PET-CT and MRI). Although MRI-based contouring showed overall larger variability than PET-CT, contouring variability depended on the interface type and was not significantly different between modalities, despite the limited observer experience with MRI. Multimodality imaging and combining different imaging characteristics might be the best approach to define

  16. Medical image computing and computer-assisted intervention - MICCAI 2006. Pt. 1. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R. [Technical Univ. of Denmark, Lyngby (Denmark). Informatics and Mathematical Modelling; Nielsen, M. [IT Univ. of Copenhagen (Denmark); Sporring, J. (eds.) [Copenhagen Univ. (Denmark). Dept. of Computer Science

    2006-07-01

    The two-volume set LNCS 4190 and LNCS 4191 constitute the refereed proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2006, held in Copenhagen, Denmark in October 2006. The program committee carefully selected 39 revised full papers and 193 revised poster papers from 578 submissions for presentation in two volumes, based on a rigorous peer reviews. The first volume includes 114 contributions related to bone shape analysis, robotics and tracking, segmentation, analysis of diffusion tensor MRI, shape analysis and morphometry, simulation and interaction, robotics and intervention, cardio-vascular applications, image analysis in oncology, brain atlases and segmentation, cardiac motion analysis, clinical applications, and registration. The second volume collects 118 papers related to segmentation, validation and quantitative image analysis, brain image processing, motion in image formation, image guided clinical applications, registration, as well as brain analysis and registration. (orig.)

  17. Medical image computing and computer-assisted intervention - MICCAI 2006. Pt. 2. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R. [Technical Univ. of Denmark, Lyngby (Denmark). Informatics and Mathematical Modelling; Nielsen, M. [IT Univ. of Copenhagen (Denmark); Sporring, J. (eds.) [Copenhagen Univ. (Denmark). Dept. of Computer Science

    2006-07-01

    The two-volume set LNCS 4190 and LNCS 4191 constitute the refereed proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2006, held in Copenhagen, Denmark in October 2006. The program committee carefully selected 39 revised full papers and 193 revised poster papers from 578 submissions for presentation in two volumes, based on a rigorous peer reviews. The first volume includes 114 contributions related to bone shape analysis, robotics and tracking, segmentation, analysis of diffusion tensor MRI, shape analysis and morphometry, simulation and interaction, robotics and intervention, cardio-vascular applications, image analysis in oncology, brain atlases and segmentation, cardiac motion analysis, clinical applications, and registration. The second volume collects 118 papers related to segmentation, validation and quantitative image analysis, brain image processing, motion in image formation, image guided clinical applications, registration, as well as brain analysis and registration. (orig.)

  18. Medical image computing and computer-assisted intervention - MICCAI 2006. Pt. 2. Proceedings

    International Nuclear Information System (INIS)

    Larsen, R.; Sporring, J.

    2006-01-01

    The two-volume set LNCS 4190 and LNCS 4191 constitute the refereed proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2006, held in Copenhagen, Denmark in October 2006. The program committee carefully selected 39 revised full papers and 193 revised poster papers from 578 submissions for presentation in two volumes, based on a rigorous peer reviews. The first volume includes 114 contributions related to bone shape analysis, robotics and tracking, segmentation, analysis of diffusion tensor MRI, shape analysis and morphometry, simulation and interaction, robotics and intervention, cardio-vascular applications, image analysis in oncology, brain atlases and segmentation, cardiac motion analysis, clinical applications, and registration. The second volume collects 118 papers related to segmentation, validation and quantitative image analysis, brain image processing, motion in image formation, image guided clinical applications, registration, as well as brain analysis and registration. (orig.)

  19. Medical image computing and computer-assisted intervention - MICCAI 2006. Pt. 1. Proceedings

    International Nuclear Information System (INIS)

    Larsen, R.; Sporring, J.

    2006-01-01

    The two-volume set LNCS 4190 and LNCS 4191 constitute the refereed proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2006, held in Copenhagen, Denmark in October 2006. The program committee carefully selected 39 revised full papers and 193 revised poster papers from 578 submissions for presentation in two volumes, based on a rigorous peer reviews. The first volume includes 114 contributions related to bone shape analysis, robotics and tracking, segmentation, analysis of diffusion tensor MRI, shape analysis and morphometry, simulation and interaction, robotics and intervention, cardio-vascular applications, image analysis in oncology, brain atlases and segmentation, cardiac motion analysis, clinical applications, and registration. The second volume collects 118 papers related to segmentation, validation and quantitative image analysis, brain image processing, motion in image formation, image guided clinical applications, registration, as well as brain analysis and registration. (orig.)

  20. Evaluation of a new software tool for the automatic volume calculation of hepatic tumors. First results

    International Nuclear Information System (INIS)

    Meier, S.; Mildenberger, P.; Pitton, M.; Thelen, M.; Schenk, A.; Bourquain, H.

    2004-01-01

    Purpose: computed tomography has become the preferred method in detecting liver carcinomas. The introduction of spiral CT added volumetric assessment of intrahepatic tumors, which was unattainable in the clinical routine with incremental CT due to complex planimetric revisions and excessive computing time. In an ongoing clinical study, a new software tool was tested for the automatic detection of tumor volume and the time needed for this procedure. Materials and methods: we analyzed patients suffering from hepatocellular carcinoma (HCC). All patients underwent treatment with repeated transcatheter chemoembolization of the hepatic arteria. The volumes of the HCC lesions detected in CT were measured with the new software tool in HepaVison (MeVis, Germany). The results were compared with manual planimetric calculation of the volume performed by three independent radiologists. Results: our first results in 16 patients show a correlation between the automatically and the manually calculated volumes (up to a difference of 2 ml) of 96.8%. While the manual method of analyzing the volume of a lesion requires 2.5 minutes on average, the automatic method merely requires about 30 seconds of user interaction time. Conclusion: These preliminary results show a good correlation between automatic and manual calculations of the tumor volume. The new software tool requires less time for accurate determination of the tumor volume and can be applied in the daily clinical routine. (orig.) [de

  1. Soft Tissue Biomechanical Modeling for Computer Assisted Surgery

    CERN Document Server

    2012-01-01

      This volume focuses on the biomechanical modeling of biological tissues in the context of Computer Assisted Surgery (CAS). More specifically, deformable soft tissues are addressed since they are the subject of the most recent developments in this field. The pioneering works on this CAS topic date from the 1980's, with applications in orthopaedics and biomechanical models of bones. More recently, however, biomechanical models of soft tissues have been proposed since most of the human body is made of soft organs that can be deformed by the surgical gesture. Such models are much more complicated to handle since the tissues can be subject to large deformations (non-linear geometrical framework) as well as complex stress/strain relationships (non-linear mechanical framework). Part 1 of the volume presents biomechanical models that have been developed in a CAS context and used during surgery. This is particularly new since most of the soft tissues models already proposed concern Computer Assisted Planning, with ...

  2. Three-dimensional reconstruction of colorectal tumors from serial tissue sections by computer graphics: a preliminary study.

    Science.gov (United States)

    Kikuchi, S; Matsuzaki, H; Kondo, K; Ohtani, Y; Ihara, A; Hiki, Y; Kakita, A; Kuwao, S

    2000-01-01

    We present herein the three-dimensional reconstruction of colorectal tumors, with particular reference to growth pattern into each layer of the colorectal wall, and measurement of tumor volume and surface area. Conventional tissue section images of colorectal tumors were analyzed using a computer graphics analysis program. The two-dimensional extent of invasion by each tumor into each layer of intestinal wall were determined from the images of each section. Based on data from multiple sections, tumor and surrounding normal tissue layers were reconstructed three-dimensionally, and volume and surface area of the tumors were determined. Using this technique, three-dimensional morphology of tumor and tumor progression into colorectal wall could be determined. Volume and surface area of the colon tumor were 4871 mm3 and 1741 mm2, respectively. Volume and surface area of the rectal tumor were 1090 mm3 and 877 mm2, respectively. This technique may provide a new approach for pathological analysis of colorectal carcinoma.

  3. Prognostic value of metabolic tumor volume as measured by fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in nasopharyngeal carcinoma.

    Science.gov (United States)

    Yoon, Young-Ho; Lee, Seok-Hwan; Hong, Sung-Lyong; Kim, Seong-Jang; Roh, Hwan-Jung; Cho, Kyu-Sup

    2014-10-01

    The prognostic value of the tumor burden characterized by the metabolic tumor volume (MTV) remains under investigation in nasopharyngeal carcinoma (NPC). The purpose of this study was to evaluate the prognostic value of the maximum standardized uptake value (SUVmax ) and MTV according to metabolic volume threshold as measured by positron emission tomography (PET)/computed tomography (CT), and other clinical factors, in patients with NPC. This study was a retrospective chart review. We evaluated the association of SUVmax , MTV2.5 , MTV3.0 , and other clinical factors with overall survival (OS) using Kaplan-Meier and Cox regression models. (MTV2.5 and MTV3.0 are the volume of hypermetabolic tissue within the regions of gross tumor volumes with a SUV value greater than the threshold values of 2.5 and 3.0, respectively.) Higher MTV2.5 of 31.45 cm(3) and MTV3.0 of 23.01 cm(3) were associated with an increased risk of death (hazard ratio [HR] = 5.028; p = 0.029), although no significant relationship was found between SUVmax and OS. Interestingly, MTV3.0 was associated with OS in both the differentiated and undifferentiated groups, although MTV2.5 was only associated with OS in the undifferentiated group. Among the clinical parameters, only radiotherapy was associated with longer OS (HR = 12.124; p < 0.001). The MTV and radiotherapy could be prognostic values associated with OS. Particularly, MTV2.5 and MTV3.0 might be valuable metabolic parameters for predicting long-term survival in patients with NPC. Furthermore, MTV3.0 may be more useful because it can be applied irrespective of pathologic subtype. © 2014 ARS-AAOA, LLC.

  4. Computer assisted roentgenology

    International Nuclear Information System (INIS)

    Trajkova, N.; Velkova, K.

    1999-01-01

    This is a report on the potentials and superiorities of computer tomography (CT), assumed as an up-to-date imaging examination method in medicine. The current trend in the development of computer assisted roentgenology consists in the implementation of new computer and communication systems promoting diagnostic and therapeutic activities. CT-study application is discussed with special reference to diagnosis and treatment of brain, lung, mediastinal and abdominal diseases. The new trends in the particular implementation of CT are presented, namely: CT-assisted biopsy, CT-assisted abscess drainage, drug administration under CT control, as well as the wide use of CT in orthopaedic surgery, otorinolaryngology etc. Also emphasis is laid on the important role played by three-dimensional technologies in computer-assisted surgery, leading to qualitatively new stage in the surgical therapeutic approach to patients

  5. COMPUTER-ASSISTED ACCOUNTING

    Directory of Open Access Journals (Sweden)

    SORIN-CIPRIAN TEIUŞAN

    2009-01-01

    Full Text Available What is computer-assisted accounting? Where is the place and what is the role of the computer in the financial-accounting activity? What is the position and importance of the computer in the accountant’s activity? All these are questions that require scientific research in order to find the answers. The paper approaches the issue of the support granted to the accountant to organize and manage the accounting activity by the computer. Starting from the notions of accounting and computer, the concept of computer-assisted accounting is introduced, it has a general character and it refers to the accounting performed with the help of the computer or using the computer to automate the procedures performed by the person who is doing the accounting activity; this is a concept used to define the computer applications of the accounting activity. The arguments regarding the use of the computer to assist accounting targets the accounting informatization, the automating of the financial-accounting activities and the endowment with modern technology of the contemporary accounting.

  6. Adaptive Radiotherapy Planning on Decreasing Gross Tumor Volumes as Seen on Megavoltage Computed Tomography Images

    International Nuclear Information System (INIS)

    Woodford, Curtis; Yartsev, Slav; Dar, A. Rashid; Bauman, Glenn; Van Dyk, Jake

    2007-01-01

    Purpose: To evaluate gross tumor volume (GTV) changes for patients with non-small-cell lung cancer by using daily megavoltage (MV) computed tomography (CT) studies acquired before each treatment fraction on helical tomotherapy and to relate the potential benefit of adaptive image-guided radiotherapy to changes in GTV. Methods and Materials: Seventeen patients were prescribed 30 fractions of radiotherapy on helical tomotherapy for non-small-cell lung cancer at London Regional Cancer Program from Dec 2005 to March 2007. The GTV was contoured on the daily MVCT studies of each patient. Adapted plans were created using merged MVCT-kilovoltage CT image sets to investigate the advantages of replanning for patients with differing GTV regression characteristics. Results: Average GTV change observed over 30 fractions was -38%, ranging from -12 to -87%. No significant correlation was observed between GTV change and patient's physical or tumor features. Patterns of GTV changes in the 17 patients could be divided broadly into three groups with distinctive potential for benefit from adaptive planning. Conclusions: Changes in GTV are difficult to predict quantitatively based on patient or tumor characteristics. If changes occur, there are points in time during the treatment course when it may be appropriate to adapt the plan to improve sparing of normal tissues. If GTV decreases by greater than 30% at any point in the first 20 fractions of treatment, adaptive planning is appropriate to further improve the therapeutic ratio

  7. Automatic segmentation of tumor-laden lung volumes from the LIDC database

    Science.gov (United States)

    O'Dell, Walter G.

    2012-03-01

    The segmentation of the lung parenchyma is often a critical pre-processing step prior to application of computer-aided detection of lung nodules. Segmentation of the lung volume can dramatically decrease computation time and reduce the number of false positive detections by excluding from consideration extra-pulmonary tissue. However, while many algorithms are capable of adequately segmenting the healthy lung, none have been demonstrated to work reliably well on tumor-laden lungs. Of particular challenge is to preserve tumorous masses attached to the chest wall, mediastinum or major vessels. In this role, lung volume segmentation comprises an important computational step that can adversely affect the performance of the overall CAD algorithm. An automated lung volume segmentation algorithm has been developed with the goals to maximally exclude extra-pulmonary tissue while retaining all true nodules. The algorithm comprises a series of tasks including intensity thresholding, 2-D and 3-D morphological operations, 2-D and 3-D floodfilling, and snake-based clipping of nodules attached to the chest wall. It features the ability to (1) exclude trachea and bowels, (2) snip large attached nodules using snakes, (3) snip small attached nodules using dilation, (4) preserve large masses fully internal to lung volume, (5) account for basal aspects of the lung where in a 2-D slice the lower sections appear to be disconnected from main lung, and (6) achieve separation of the right and left hemi-lungs. The algorithm was developed and trained to on the first 100 datasets of the LIDC image database.

  8. Tumor and normal structures volume localization and quantitation in 3D radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Anselmi, R.; Andreucci, L.

    1995-01-01

    Improvements in imaging technology have significantly enhanced the ability of the radiation oncologist to stage and to evaluate the response of tumor during and after treatment. Over the last few year, in fact, computed tomography (CT), magnetic resonance spectroscopy (MRS), positron emission tomography (PET), single photon emission computed tomography (SPECT) imaging radiolabelled monoclonal tumor antibodies have allowed tumor definition and evaluation. Concerning the above mentioned techniques accurate methods for the integration of morphological (CT, MRI) and functional (PET, SPECT, MRS) information can be very useful for volumes definition. In fact three-dimensional treatment planning depends heavily on volume displays and calculation based on volumes to convey information to the radiation oncologist, physicist and dosimetrist. The accuracy and reproducibility of the methods for creating these volumes are fundamental limitations of current treatment planning systems. Slice by slice manual contouring, which is extremely labor-intensive, and automatic edge detection, which has a high failure rate and requires human intervention are representative of the current standard of practice. The aim of our work is both to develop methods of image data integration and automatic segmentation, and to make the treatment planning system able to combine these multiple information in unified data set in order to get a better tumor volume definition and dose distribution calculation. Then the possibility of using morphological and functional images and other information coming from MR spectroscopy and electronic or confocal microscopy can allow the development into the treatment planning system of biological calculation models for evaluating tumor and normal tissue control probabilities (TCP, NTCP). The definitive use of these models into the 3-D treatment plannings will offer a considerable improvement in the biological efficacy of radiotherapy and it will constitute the object

  9. Technical progress, the concept of individualized cancer treatment and the innovation of computer-assisted radiotherapy planning

    International Nuclear Information System (INIS)

    Merkle, K.; Tanneberger, S.; Matschke, S.

    1985-01-01

    After a first step of cancerogenesis, the further development of the tumor is an individual process. At the end of this process the tumor is formed as an individual in the individual. The individuality of cancer exists on the level of organs, tissues and cells and includes an individual tumor-host relationship. Today, optimized cancer treatment requires a most precise biological characterization possible of the tumor and of the tumor-host relationship, which will provide objective information about the individual character of every tumor. Routine analysis and strict therapeutic consideration of the clinical and biological individuality of human cancer can offer real chances for the improvement of cancer treatment. A routine acquisition of individual tumor characteristics will be possible only if methods and equipment are available for the registration of suitable parameters. In this context technical innovations have an essential influence on the realization of the concept of individualized cancer treatment. With the method of flow cytophotometry and other techniques examples are given in how far the ideas of individual cancer management can be realized by introduction of new technical solutions into medical research and clinical practice. Unfortunately there is still a lack of methodology in individualizing cancer treatment. The individualization of radiotherapy is connected to an extremely high degree of technical innovations. Particularly this refers to the topometrical description of the target volume in relation to the adjacent anatomical structures and the body contour as well as the fitting of isodoses to the shape and size of the target volume. As an example of innovation of a technical solution for individual radiotherapy planning the computer-assisted radiotherapy planning system DOPSY is described. (author)

  10. Tumor response parameters for head and neck cancer derived from tumor-volume variation during radiation therapy

    International Nuclear Information System (INIS)

    Chvetsov, Alexei V.

    2013-01-01

    Purpose: The main goal of this paper is to reconstruct a distribution of cell survival fractions from tumor-volume variation for a heterogeneous group of head and neck cancer patients and compare this distribution to the data from predictive assays. Methods: To characterize the tumor-volume variation during radiation therapy treatment, the authors use a two-level tumor-volume model of cell population that separates the entire tumor cell population into two subpopulations of viable cells and lethally damaged cells. This parameterized radiobiological model is integrated with a least squares objective function and a simulated annealing optimization algorithm to describe time-dependent tumor-volume variation rates in individual patients. Several constraints have been used in the optimization problem because tumor-volume variation during radiotherapy is described by a sum of exponentials; therefore, the problem of accurately fitting a model to measured data is ill-posed. The model was applied to measured tumor-volume variation curves from a clinical study on tumor-volume variation during radiotherapy for 14 head and neck cancer patients in which an integrated CT/linear particle accelerator (LINAC) system was used for tumor-volume measurements. Results: The two-level cell population tumor-volume modeling is capable of describing tumor-volume variation throughout the entire treatment for 11 of the 14 patients. For three patients, the tumor-volume variation was described only during the initial part of treatment, a fact that may be related to the neglected hypoxia in the two-level approximation. The predicted probability density distribution for the survival fractions agrees with the data obtained using in vitro studies with predictive assays. The mean value 0.35 of survival fraction obtained in this study is larger than the value 0.32 from in vitro studies, which could be expected because of greater repair in vivo. The mean half-life obtained in this study for the head

  11. Preliminary study of the internal margin of the gross tumor volume in thoracic esophageal cancer

    International Nuclear Information System (INIS)

    Li, Jiancheng; Pan, Jianji; Wang, Linhua; Zhao, Yunhui; Liu, Di; Chen, Cheng; Zhang, He Ping; Wang, Xiaoliang

    2012-01-01

    Purpose. - To measure the displacement of the tumor of the gross tumor volume (GTV) of thoracic esophageal cancer in the calm states of end-inspiration and end-expiration for determining the internal margin of the GTV (IGTV). Methods. - Twenty-two patients with thoracic esophageal cancer who were unable to undergo surgery were identified in our hospital. The patients received radiotherapy. By using 16-slice spiral computed tomography (CT), we acquired the calm states of end-inspiration and end-expiration. The displacement and volume changes in tumor target volume were measured, and the changes were analyzed to determine if these were associated with the tidal volume and the location and length of the target volume V. In the end, we analyzed the displacement of tumor target volume and calculated the internal margin of the GTV by empirical formula. Results. - The average tidal volume was 463.6 ml. The average GTV at end-inspiration was 33.3 ml and at end-expiration was 33.35 ml. Three was not any significant between two groups (T -0.034, P > 0.05). The IGTV (X-axis direction) was 3.09 mm for the right sector and 4.08 mm for the left border; the IGTV (Z-axis direction) was 3.96 mm for the anterior border and 2.83 mm for the posterior border; and the IGTV (Y-axis direction) was 7.31 mm for the upper boundary (head direction) and 10.16 mm for the lower boundary (feet direction). The motion of the GTV showed no significant correlation with the tidal volume of patients and the length of the tumor, but in relation to the tumor location, the displacement of the lower thoracic and the middle thoracic target volumes occurred in the direction of the anterior and right, which were not significantly different (T = 0.859, 0.229, P > 0.05) The significant differences were observed for the other directions (P < 0.05). Conclusions. - Because of respiratory and organ movements, the displacement of the tumor target volume was different in all directions. Therefore, we recommend that

  12. Acute tumor vascular effects following fractionated radiotherapy in human lung cancer: In vivo whole tumor assessment using volumetric perfusion computed tomography

    International Nuclear Information System (INIS)

    Ng, Q.-S.; Goh, Vicky; Milner, Jessica; Padhani, Anwar R.; Saunders, Michele I.; Hoskin, Peter J.

    2007-01-01

    Purpose: To quantitatively assess the in vivo acute vascular effects of fractionated radiotherapy for human non-small-cell lung cancer using volumetric perfusion computed tomography (CT). Methods and Materials: Sixteen patients with advanced non-small-cell lung cancer, undergoing palliative radiotherapy delivering 27 Gy in 6 fractions over 3 weeks, were scanned before treatment, and after the second (9 Gy), fourth (18 Gy), and sixth (27 Gy) radiation fraction. Using 16-detector CT, multiple sequential volumetric acquisitions were acquired after intravenous contrast agent injection. Measurements of vascular blood volume and permeability for the whole tumor volume were obtained. Vascular changes at the tumor periphery and center were also measured. Results: At baseline, lung tumor vascularity was spatially heterogeneous with the tumor rim showing a higher vascular blood volume and permeability than the center. After the second, fourth, and sixth fractions of radiotherapy, vascular blood volume increased by 31.6% (paired t test, p = 0.10), 49.3% (p = 0.034), and 44.6% (p = 0.0012) respectively at the tumor rim, and 16.4% (p = 0.29), 19.9% (p = 0.029), and 4.0% (p = 0.0050) respectively at the center of the tumor. After the second, fourth, and sixth fractions of radiotherapy, vessel permeability increased by 18.4% (p = 0.022), 44.8% (p = 0.0048), and 20.5% (p = 0.25) at the tumor rim. The increase in permeability at the tumor center was not significant after radiotherapy. Conclusion: Fractionated radiotherapy increases tumor vascular blood volume and permeability in human non-small-cell lung cancer. We have established the spatial distribution of vascular changes after radiotherapy; greater vascular changes were demonstrated at the tumor rim compared with the center

  13. Computer-assisted stereology and automated image analysis for quantification of tumor infiltrating lymphocytes in colon cancer.

    Science.gov (United States)

    Eriksen, Ann C; Andersen, Johnnie B; Kristensson, Martin; dePont Christensen, René; Hansen, Torben F; Kjær-Frifeldt, Sanne; Sørensen, Flemming B

    2017-08-29

    Precise prognostic and predictive variables allowing improved post-operative treatment stratification are missing in patients treated for stage II colon cancer (CC). Investigation of tumor infiltrating lymphocytes (TILs) may be rewarding, but the lack of a standardized analytic technique is a major concern. Manual stereological counting is considered the gold standard, but digital pathology with image analysis is preferred due to time efficiency. The purpose of this study was to compare manual stereological estimates of TILs with automatic counts obtained by image analysis, and at the same time investigate the heterogeneity of TILs. From 43 patients treated for stage II CC in 2002 three paraffin embedded, tumor containing tissue blocks were selected one of them representing the deepest invasive tumor front. Serial sections from each of the 129 blocks were immunohistochemically stained for CD3 and CD8, and the slides were scanned. Stereological estimates of the numerical density and area fraction of TILs were obtained using the computer-assisted newCAST stereology system. For the image analysis approach an app-based algorithm was developed using Visiopharm Integrator System software. For both methods the tumor areas of interest (invasive front and central area) were manually delineated by the observer. Based on all sections, the Spearman's correlation coefficients for density estimates varied from 0.9457 to 0.9638 (p heterogeneity, intra-class correlation coefficients (ICC) for CD3+ TILs varied from 0.615 to 0.746 in the central area, and from 0.686 to 0.746 in the invasive area. ICC for CD8+ TILs varied from 0.724 to 0.775 in the central area, and from 0.746 to 0.765 in the invasive area. Exact objective and time efficient estimates of numerical densities and area fractions of CD3+ and CD8+ TILs in stage II colon cancer can be obtained by image analysis and are highly correlated to the corresponding estimates obtained by the gold standard based on stereology

  14. Gross tumor volume (GTV) and clinical target volume (CTV) for radiation therapy of benign skull base tumours

    International Nuclear Information System (INIS)

    Maire, J.P.; Liguoro, D.; San Galli, F.

    2001-01-01

    Skull base tumours represent a out 35 to 40% of all intracranial tumours. There are now many reports in the literature confirming the fact that about 80 to 90% of such tumours are controlled with fractionated radiotherapy. Stereotactic and 3-dimensional treatment planning techniques increase local control and central nervous system tolerance. Definition of the gross tumor volume (GTV) is generally easy with currently available medical imaging systems and computers for 3-dimensional dosimetry. The definition of the clinical target volume (CTV) is more difficult to appreciate: it is defined from the CTV plus a margin, which depends on the histology and anterior therapeutic history of the tumour. It is important to take into account the visible tumour and its possible extension pathways (adjacent bone, holes at the base of skull) and/or an anatomic region (sella turcica + adjacent cavernous sinus). It is necessary to evaluate these volumes with CT Scan and MRI to appreciate tumor extension in a 3-dimensional approach, in order to reduce the risk of marginal recurrences. The aim of this paper is to discuss volume definition as a function of tumour site and tumour type to be irradiated. (authors)

  15. Artifacts in conventional computed tomography (CT) and free breathing four-dimensional CT induce uncertainty in gross tumor volume determination

    DEFF Research Database (Denmark)

    Persson, Gitte Fredberg; Nygaard, Ditte Eklund; Af Rosenschöld, Per Munck

    2011-01-01

    was to compare delineated gross tumor volume (GTV) sizes in 3DCT, 4DCT, and BHCT scans of patients with lung tumors. METHODS AND MATERIALS: A total of 36 patients with 46 tumors referred for stereotactic radiotherapy of lung tumors were included. All patients underwent positron emission tomography (PET)/CT, 4DCT...

  16. SU-E-T-429: Uncertainties of Cell Surviving Fractions Derived From Tumor-Volume Variation Curves

    International Nuclear Information System (INIS)

    Chvetsov, A

    2014-01-01

    Purpose: To evaluate uncertainties of cell surviving fraction reconstructed from tumor-volume variation curves during radiation therapy using sensitivity analysis based on linear perturbation theory. Methods: The time dependent tumor-volume functions V(t) have been calculated using a twolevel cell population model which is based on the separation of entire tumor cell population in two subpopulations: oxygenated viable and lethally damaged cells. The sensitivity function is defined as S(t)=[δV(t)/V(t)]/[δx/x] where δV(t)/V(t) is the time dependent relative variation of the volume V(t) and δx/x is the relative variation of the radiobiological parameter x. The sensitivity analysis was performed using direct perturbation method where the radiobiological parameter x was changed by a certain error and the tumor-volume was recalculated to evaluate the corresponding tumor-volume variation. Tumor volume variation curves and sensitivity functions have been computed for different values of cell surviving fractions from the practically important interval S 2 =0.1-0.7 using the two-level cell population model. Results: The sensitivity functions of tumor-volume to cell surviving fractions achieved a relatively large value of 2.7 for S 2 =0.7 and then approached zero as S 2 is approaching zero Assuming a systematic error of 3-4% we obtain that the relative error in S 2 is less that 20% in the range S2=0.4-0.7. This Resultis important because the large values of S 2 are associated with poor treatment outcome should be measured with relatively small uncertainties. For the very small values of S2<0.3, the relative error can be larger than 20%; however, the absolute error does not increase significantly. Conclusion: Tumor-volume curves measured during radiotherapy can be used for evaluation of cell surviving fractions usually observed in radiation therapy with conventional fractionation

  17. The importance of tumor volume in the prognosis of patients with glioblastoma. Comparison of computerized volumetry and geometric models

    International Nuclear Information System (INIS)

    Iliadis, Georgios; Misailidou, Despina; Selviaridis, Panagiotis; Chatzisotiriou, Athanasios; Kalogera-Fountzila, Anna; Fragkoulidi, Anna; Fountzilas, George; Baltas, Dimos; Tselis, Nikolaos; Zamboglou, Nikolaos

    2009-01-01

    Background and purpose: the importance of tumor volume as a prognostic factor in high-grade gliomas is highly controversial and there are numerous methods estimating this parameter. In this study, a computer-based application was used in order to assess tumor volume from hard copies and a survival analysis was conducted in order to evaluate the prognostic significance of preoperative volumetric data in patients harboring glioblastomas. Patients and methods: 50 patients suffering from glioblastoma were analyzed retrospectively. Tumor volume was determined by the various geometric models as well as by an own specialized software (Volumio). Age, performance status, type of excision, and tumor location were also included in the multivariate analysis. Results: the spheroid and rectangular models overestimated tumor volume, while the ellipsoid model offered the best approximation. Volume failed to attain any statistical significance in prognosis, while age and performance status confirmed their importance in progression-free and overall survival of patients. Conclusion: geometric models provide a rough approximation of tumor volume and should not be used, as accurate determination of size is of paramount importance in order to draw safe conclusions in oncology. Although the significance of volumetry was not disclosed, further studies are definitely required. (orig.)

  18. Comparison of different threshold 18FDG PET with computer tomography for defining gross tumor volume in non-small cell lung carcinoma

    International Nuclear Information System (INIS)

    Chen Shaoqing; Yu Jinming; Xing Ligang; Gong Heyi; Fu Zheng; Yang Guoren

    2006-01-01

    Objective: Under different standard uptake value(SUV), to assess gross tumor volume (GTV) definition for non-small cell lung cancer (NSCLC) with 18-fluoro-deoxy-glueose positron emission tomography( 18 FDG PET) both under definite threshold (42 percent threshold) and various relative threshold (threshold SUV/maximum SUV) derived from the linear regressive function, threshold SUV=0.307 x (mean target SUV) + 0.588, with computer tomography(CT). Methods: Of 20 patients with non-small cell lung cancer, the CT GTV (GTV CT ), PET GTV with 42 percents threshold (GTV 42% ) and PET GTV with relative threshold (GTV relate ) were obtained and compared. Results: The mean GTV 42% , mean GTV relate and mean GTV CT was (13 812.5±13 841.4), (24 325.3±22 454.7) and (28350.9± 26 079.8) mm 3 , respectively, with the difference in mean GTV among these three methods significant (F =. 10, P 42% was smaller than the GTV relate and the GTV CT (P relate and GTV CT (P = 0.125 ). Conclusion: The relative threshold is more suitable to define the gross tumor volume than the definite threshold. (authors)

  19. Correlation between tumor regression grade and rectal volume in neoadjuvant concurrent chemoradiotherapy for rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hong Seok; Choi, Doo Ho; Park, Hee Chul; Park, Won; Yu, Jeong Il; Chung, Kwang Zoo [Dept. of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To determine whether large rectal volume on planning computed tomography (CT) results in lower tumor regression grade (TRG) after neoadjuvant concurrent chemoradiotherapy (CCRT) in rectal cancer patients. We reviewed medical records of 113 patients treated with surgery following neoadjuvant CCRT for rectal cancer between January and December 2012. Rectal volume was contoured on axial images in which gross tumor volume was included. Average axial rectal area (ARA) was defined as rectal volume divided by longitudinal tumor length. The impact of rectal volume and ARA on TRG was assessed. Average rectal volume and ARA were 11.3 mL and 2.9 cm². After completion of neoadjuvant CCRT in 113 patients, pathologic results revealed total regression (TRG 4) in 28 patients (25%), good regression (TRG 3) in 25 patients (22%), moderate regression (TRG 2) in 34 patients (30%), minor regression (TRG 1) in 24 patients (21%), and no regression (TRG0) in 2 patients (2%). No difference of rectal volume and ARA was found between each TRG groups. Linear correlation existed between rectal volume and TRG (p = 0.036) but not between ARA and TRG (p = 0.058). Rectal volume on planning CT has no significance on TRG in patients receiving neoadjuvant CCRT for rectal cancer. These results indicate that maintaining minimal rectal volume before each treatment may not be necessary.

  20. Correlation between tumor regression grade and rectal volume in neoadjuvant concurrent chemoradiotherapy for rectal cancer

    International Nuclear Information System (INIS)

    Lee, Hong Seok; Choi, Doo Ho; Park, Hee Chul; Park, Won; Yu, Jeong Il; Chung, Kwang Zoo

    2016-01-01

    To determine whether large rectal volume on planning computed tomography (CT) results in lower tumor regression grade (TRG) after neoadjuvant concurrent chemoradiotherapy (CCRT) in rectal cancer patients. We reviewed medical records of 113 patients treated with surgery following neoadjuvant CCRT for rectal cancer between January and December 2012. Rectal volume was contoured on axial images in which gross tumor volume was included. Average axial rectal area (ARA) was defined as rectal volume divided by longitudinal tumor length. The impact of rectal volume and ARA on TRG was assessed. Average rectal volume and ARA were 11.3 mL and 2.9 cm². After completion of neoadjuvant CCRT in 113 patients, pathologic results revealed total regression (TRG 4) in 28 patients (25%), good regression (TRG 3) in 25 patients (22%), moderate regression (TRG 2) in 34 patients (30%), minor regression (TRG 1) in 24 patients (21%), and no regression (TRG0) in 2 patients (2%). No difference of rectal volume and ARA was found between each TRG groups. Linear correlation existed between rectal volume and TRG (p = 0.036) but not between ARA and TRG (p = 0.058). Rectal volume on planning CT has no significance on TRG in patients receiving neoadjuvant CCRT for rectal cancer. These results indicate that maintaining minimal rectal volume before each treatment may not be necessary

  1. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias; Furtwaengler, Alex

    2003-01-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST ( 5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  2. Diversion Path Analysis handbook. Volume 4 (of 4 volumes). Computer Program 2

    International Nuclear Information System (INIS)

    Schleter, J.C.

    1978-11-01

    The FORTRAN IV computer program, DPA Computer Program 2 (DPACP-2) is used to produce tables and statistics on modifications identified when performing a Diversion Path Analysis (DPA) in accord with the methodology given in Volume 1. The program requires 259088 bytes exclusive of the operating system. The data assembled and tabulated by DPACP-2 assist the DPA team in analyzing and evaluating modifications to the plant's safeguards system that would eliminate, or reduce the severity of, vulnerabilities identified by means of the DPA. These vulnerabilities relate to the capability of the plant's material control and material accounting subsystems to indicate diversion of special nuclear material (SNM) by a knowledgeable insider

  3. Computer-assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.

    1988-01-01

    New digital imaging modalities and more sophisticated image processing systems will have a profound effect on those areas of medicine concerned with imaging. This mainly means computer-assisted radiology (CAR) and implies a transition from analog film systems to digital imaging systems, integration of digital imaging modalities through picture archiving and communication systems (PACS) and the graduated employment of image-oriented medical work stations (MWS) for computer-assisted representation, communication, diagnosis, and therapy planning. (orig.) [de

  4. [Endoscopic assistance in surgery of cerebellopontine angle tumors].

    Science.gov (United States)

    Poshataev, V K; Shimansky, V N; Tanyashin, S V; Karnaukhov, V V

    2014-01-01

    During the period of 2010-2012, 33 patients with cerebellopontine angle tumors were operated on at the Burdenko Neurosurgical Institute (Moscow, Russia) using different types of endoscopic assistance. All patients were operated on via the retrosigmoid suboccipital approach in semi-sitting and prone positions. 30° and 70° endoscopes were used during the surgery. Endoscopic assistance allowed us to increase the completeness of tumor removal and to reduce the risk of postoperative complications by retaining the anatomic integrity of cranial nerves and vascular structures in the base of the posterior cranial fossa. These benefits made it possible to maintain and improve quality of life in patients with CPA tumors in the postoperative period.

  5. Three-Dimensional Image Fusion of 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography and Contrast-Enhanced Computed Tomography for Computer-Assisted Planning of Maxillectomy of Recurrent Maxillary Squamous Cell Carcinoma and Defect Reconstruction.

    Science.gov (United States)

    Yu, Yao; Zhang, Wen-Bo; Liu, Xiao-Jing; Guo, Chuan-Bin; Yu, Guang-Yan; Peng, Xin

    2017-06-01

    The purpose of this study was to describe new technology assisted by 3-dimensional (3D) image fusion of 18 F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) for computer planning of a maxillectomy of recurrent maxillary squamous cell carcinoma and defect reconstruction. Treatment of recurrent maxillary squamous cell carcinoma usually includes tumor resection and free flap reconstruction. FDG-PET/CT provided images of regions of abnormal glucose uptake and thus showed metabolic tumor volume to guide tumor resection. CECT data were used to create 3D reconstructed images of vessels to show the vascular diameters and locations, so that the most suitable vein and artery could be selected during anastomosis of the free flap. The data from preoperative maxillofacial CECT scans and FDG-PET/CT imaging were imported into the navigation system (iPlan 3.0; Brainlab, Feldkirchen, Germany). Three-dimensional image fusion between FDG-PET/CT and CECT was accomplished using Brainlab software according to the position of the 2 skulls simulated in the CECT image and PET/CT image, respectively. After verification of the image fusion accuracy, the 3D reconstruction images of the metabolic tumor, vessels, and other critical structures could be visualized within the same coordinate system. These sagittal, coronal, axial, and 3D reconstruction images were used to determine the virtual osteotomy sites and reconstruction plan, which was provided to the surgeon and used for surgical navigation. The average shift of the 3D image fusion between FDG-PET/CT and CECT was less than 1 mm. This technique, by clearly showing the metabolic tumor volume and the most suitable vessels for anastomosis, facilitated resection and reconstruction of recurrent maxillary squamous cell carcinoma. We used 3D image fusion of FDG-PET/CT and CECT to successfully accomplish resection and reconstruction of recurrent maxillary squamous cell carcinoma

  6. Dynamic-thresholding level set: a novel computer-aided volumetry method for liver tumors in hepatic CT images

    Science.gov (United States)

    Cai, Wenli; Yoshida, Hiroyuki; Harris, Gordon J.

    2007-03-01

    Measurement of the volume of focal liver tumors, called liver tumor volumetry, is indispensable for assessing the growth of tumors and for monitoring the response of tumors to oncology treatments. Traditional edge models, such as the maximum gradient and zero-crossing methods, often fail to detect the accurate boundary of a fuzzy object such as a liver tumor. As a result, the computerized volumetry based on these edge models tends to differ from manual segmentation results performed by physicians. In this study, we developed a novel computerized volumetry method for fuzzy objects, called dynamic-thresholding level set (DT level set). An optimal threshold value computed from a histogram tends to shift, relative to the theoretical threshold value obtained from a normal distribution model, toward a smaller region in the histogram. We thus designed a mobile shell structure, called a propagating shell, which is a thick region encompassing the level set front. The optimal threshold calculated from the histogram of the shell drives the level set front toward the boundary of a liver tumor. When the volume ratio between the object and the background in the shell approaches one, the optimal threshold value best fits the theoretical threshold value and the shell stops propagating. Application of the DT level set to 26 hepatic CT cases with 63 biopsy-confirmed hepatocellular carcinomas (HCCs) and metastases showed that the computer measured volumes were highly correlated with those of tumors measured manually by physicians. Our preliminary results showed that DT level set was effective and accurate in estimating the volumes of liver tumors detected in hepatic CT images.

  7. Computer-assisted instruction

    NARCIS (Netherlands)

    Voogt, J.; Fisser, P.; Wright, J.D.

    2015-01-01

    Since the early days of computer technology in education in the 1960s, it was claimed that computers can assist instructional practice and hence improve student learning. Since then computer technology has developed, and its potential for education has increased. In this article, we first discuss

  8. A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography

    International Nuclear Information System (INIS)

    Aristophanous, Michalis; Penney, Bill C.; Martel, Mary K.; Pelizzari, Charles A.

    2007-01-01

    The increased interest in 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an ''analysis region'' to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of the

  9. Method and timing of tumor volume measurement for outcome prediction in cervical cancer using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mayr, Nina A.; Taoka, Toshiaki; Yuh, William T.C.; Denning, Leah M.; Zhen, Weining K.; Paulino, Arnold C.; Gaston, Robert C.; Sorosky, Joel I.; Meeks, Sanford L.; Walker, Joan L.; Mannel, Robert S.; Buatti, John M.

    2002-01-01

    Purpose: Recently, imaging-based tumor volume before, during, and after radiation therapy (RT) has been shown to predict tumor response in cervical cancer. However, the effectiveness of different methods and timing of imaging-based tumor size assessment have not been investigated. The purpose of this study was to compare the predictive value for treatment outcome derived from simple diameter-based ellipsoid tumor volume measurement using orthogonal diameters (with ellipsoid computation) with that derived from more complex contour tracing/region-of-interest (ROI) analysis 3D tumor volumetry. Methods and Materials: Serial magnetic resonance imaging (MRI) examinations were prospectively performed in 60 patients with advanced cervical cancer (Stages IB 2 -IVB/recurrent) at the start of RT, during early RT (20-25 Gy), mid-RT (45-50 Gy), and at follow-up (1-2 months after RT completion). ROI-based volumetry was derived by tracing the entire tumor region in each MR slice on the computer work station. For the diameter-based surrogate ''ellipsoid volume,'' the three orthogonal diameters (d 1 , d 2 , d 3 ) were measured on film hard copies to calculate volume as an ellipsoid (d 1 x d 2 x d 3 x π/6). Serial tumor volumes and regression rates determined by each method were correlated with local control, disease-free and overall survival, and the results were compared between the two measuring methods. Median post-therapy follow-up was 4.9 years (range, 2.0-8.2 years). Results: The best method and time point of tumor size measurement for the prediction of outcome was the tumor regression rate in the mid-therapy MRI examination (at 45-50 Gy) using 3D ROI volumetry. For the pre-RT measurement both the diameter-based method and ROI volumetry provided similar predictive accuracy, particularly for patients with small ( 3 ) and large (≥100 cm 3 ) pre-RT tumor size. However, the pre-RT tumor size measured by either method had much less predictive value for the intermediate-size (40

  10. Computer-Aided Detection of Kidney Tumor on Abdominal Computed Tomography Scans

    International Nuclear Information System (INIS)

    Kim, D.Y.; Park, J.W.

    2004-01-01

    Purpose: To implement a computer-aided detection system for kidney segmentation and kidney tumor detection on abdominal computed tomography (CT) scans. Material and Methods: Abdominal CT images were digitized with a film digitizer, and a gray-level threshold method was used to segment the kidney. Based on texture analysis performed on sample images of kidney tumors, a portion of the kidney tumor was selected as seed region for start point of the region-growing process. The average and standard deviations were used to detect the kidney tumor. Starting at the detected seed region, the region-growing method was used to segment the kidney tumor with intensity values used as an acceptance criterion for a homogeneous test. This test was performed to merge the neighboring region as kidney tumor boundary. These methods were applied on 156 transverse images of 12 cases of kidney tumors scanned using a G.E. Hispeed CT scanner and digitized with a Lumisys LS-40 film digitizer. Results: The computer-aided detection system resulted in a kidney tumor detection sensitivity of 85% and no false-positive findings. Conclusion: This computer-aided detection scheme was useful for kidney tumor detection and gave the characteristics of detected kidney tumors

  11. Grading of vestibular schwannomas and corresponding tumor volumes: ramifications for radiosurgery.

    Science.gov (United States)

    Mindermann, T; Schlegel, I

    2013-01-01

    Patients with vestibular schwannomas (VS) are either assigned to watchful waiting, microsurgical resection, or radiosurgery. Decision making on how to proceed is based on parameters such as age, tumor growth, loss of hearing, and the tumor's Koos grading. In order to correlate Koos grading with tumor volume, patient records of 235 patients with VS who underwent Gamma Knife radiosurgery (GKRS) were retrospectively reviewed. From 1994 to 2009, 235 consecutive patients underwent GKRS for sporadic VS at the Zurich Gamma Knife Center. Median follow up was 62.8 ± 33.0 months. Of the 235 tumors, 32 (13.6 %) were graded Koos I with a volume of 0.25 ± 0.3 cc; 71 (30.2 %) were graded Koos II with a volume of 0.57 ± 0.54 cc; 70 (29.8 %) were graded Koos III with a volume of 1.82 ± 1.88 cc; and 62 (26.4 %) were graded Koos IV with a volume of 4.17 ± 2.75 cc. Tumor progression was defined as a volume increase > 20 % at 2 years or later following GKRS. Overall tumor progression occurred in 21/235 (8.9 %) patients at 3.4 ± 0.9 years. Tumor progression did not differ statistically significantly in the various Koos grades: 1/32 (3.1 %) patients with VS Koos Grade I, 7/71 (9.8 %) patients with VS Koos Grade II, 6/70 (8.6 %) patients with VS Koos Grade III, and 7/62 (11.3 %) patients with VS Koos Grade IV. To our knowledge, this is the first work correlating the various Koos grades of VS to their respective tumor volumes. In our patients, tumor volumes of VS Koos Grade IV were limited because all of our patients were eligible for radiosurgery. In our series, the outcome following GKRS for patients with VS Koos Grade IV tumors did not differ from patients with VS Koos Grades I-III. We therefore suggest to limit Koos Grade IV VS to tumor volumes 6 cc that may not be eligible for radiosurgery.

  12. Computational radiology for orthopaedic interventions

    CERN Document Server

    Li, Shuo

    2016-01-01

    This book provides a cohesive overview of the current technological advances in computational radiology, and their applications in orthopaedic interventions. Contributed by the leading researchers in the field, this volume covers not only basic computational radiology techniques such as statistical shape modeling, CT/MRI segmentation, augmented reality and micro-CT image processing, but also the applications of these techniques to various orthopaedic interventional tasks. Details about following important state-of-the-art development are featured: 3D preoperative planning and patient-specific instrumentation for surgical treatment of long-bone deformities, computer assisted diagnosis and planning of periacetabular osteotomy and femoroacetabular impingement, 2D-3D reconstruction-based planning of total hip arthroplasty, image fusion for  computer-assisted bone tumor surgery, intra-operative three-dimensional imaging in fracture treatment, augmented reality based orthopaedic interventions and education, medica...

  13. Gold markers for tumor localization and target volume delineation in radiotherapy for rectal cancer

    International Nuclear Information System (INIS)

    Vorwerk, Hilke; Christiansen, Hans; Hess, Clemens Friedrich; Hermann, Robert Michael; Liersch, Thorsten; Ghadimi, Michael; Rothe, Hilka

    2009-01-01

    In locally advanced rectal cancer, neoadjuvant radiochemotherapy is indicated. To improve target volume definition for radiotherapy planning, the potential of implanted gold markers in the tumor region was evaluated. In nine consecutive patients, two to three gold markers were implanted in the tumor region during rigid rectoscopy. Computed tomography scans were performed during treatment planning. All electronic portal imaging devices (EPIDs) recorded during treatment series were analyzed. All patients underwent complete tumor resection with meticulous histopathologic examination. The gold markers could easily be implanted into the mesorectal tissue at the caudal tumor border without any complications. They were helpful in identifying the inferior border of the planning target volume in order to spare normal tissue (in particular anal structures). No significant shift of the markers was found during the course of therapy. Marker matching of the EPIDs did not improve patient positioning in comparison to bone structure matching. The former position of at least one marker could be identified in all patients during histopathologic examination. The use of gold marker enables a more precise definition of the target volume for radiotherapy in patients with rectal cancer. This could eventually allow a better protection of anal structures of patients with a tumor localization = 5 cm cranial of the anal sphincter. The implantation of the gold markers improved communication between the surgeon, the radiooncologist and the pathologist resulting in intensified exchange of relevant informations. (orig.)

  14. Micro-computed tomography derived anisotropy detects tumor provoked deviations in bone in an orthotopic osteosarcoma murine model.

    Directory of Open Access Journals (Sweden)

    Heather A Cole

    Full Text Available Radiographic imaging plays a crucial role in the diagnosis of osteosarcoma. Currently, computed-tomography (CT is used to measure tumor-induced osteolysis as a marker for tumor growth by monitoring the bone fractional volume. As most tumors primarily induce osteolysis, lower bone fractional volume has been found to correlate with tumor aggressiveness. However, osteosarcoma is an exception as it induces osteolysis and produces mineralized osteoid simultaneously. Given that competent bone is highly anisotropic (systematic variance in its architectural order renders its physical properties dependent on direction of load and that tumor induced osteolysis and osteogenesis are structurally disorganized relative to competent bone, we hypothesized that μCT-derived measures of anisotropy could be used to qualitatively and quantitatively detect osteosarcoma provoked deviations in bone, both osteolysis and osteogenesis, in vivo. We tested this hypothesis in a murine model of osteosarcoma cells orthotopically injected into the tibia. We demonstrate that, in addition to bone fractional volume, μCT-derived measure of anisotropy is a complete and accurate method to monitor osteosarcoma-induced osteolysis. Additionally, we found that unlike bone fractional volume, anisotropy could also detect tumor-induced osteogenesis. These findings suggest that monitoring tumor-induced changes in the structural property isotropy of the invaded bone may represent a novel means of diagnosing primary and metastatic bone tumors.

  15. Quantification of Tumor Volume Changes During Radiotherapy for Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Fox, Jana; Ford, Eric; Redmond, Kristin; Zhou, Jessica; Wong, John; Song, Danny Y.

    2009-01-01

    Purpose: Dose escalation for lung cancer is limited by normal tissue toxicity. We evaluated sequential computed tomography (CT) scans to assess the possibility of adaptively reducing treatment volumes by quantifying the tumor volume reduction occurring during a course of radiotherapy (RT). Methods and Materials: A total of 22 patients underwent RT for Stage I-III non-small-cell lung cancer with conventional fractionation; 15 received concurrent chemotherapy. Two repeat CT scans were performed at a nominal dose of 30 Gy and 50 Gy. Respiration-correlated four-dimensional CT scans were used for evaluation of respiratory effects in 17 patients. The gross tumor volume (GTV) was delineated on simulation and all individual phases of the repeat CT scans. Parenchymal tumor was evaluated unless the nodal volume was larger or was the primary. Subsequent image sets were spatially co-registered with the simulation data for evaluation. Results: The median GTV reduction was 24.7% (range, -0.3% to 61.7%; p 100 cm 3 vs. 3 , and hilar and/or mediastinal involvement vs. purely parenchymal or pleural lesions. A tendency toward a greater volume reduction with increasing dose was seen, although this did not reach statistical significance. Conclusion: The results of this study have demonstrated significant alterations in the GTV seen on repeat CT scans during RT. These observations raise the possibility of using an adaptive approach toward RT of non-small-cell lung cancer to minimize the dose to normal structures and more safely increase the dose directed at the target tissues.

  16. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-06-15

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery.

  17. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    International Nuclear Information System (INIS)

    2008-01-01

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery

  18. Adenocarcinomas of the esophagus: Response to chemoradiotherapy is associated with decrease of metabolic tumor volume as measured on PET-CT

    International Nuclear Information System (INIS)

    Roedl, Johannes B.; Colen, Rivka R.; Holalkere, Nagaraj S.; Fischman, Alan J.; Choi, Noah C.; Blake, Michael A.

    2008-01-01

    Purpose: We determined whether evaluation of treatment response is feasible by measuring metabolic tumor volume parameters on 18F-FDG (Fluorodeoxyglucose) PET-CT (Positron emission tomography-Computed tomography). We compared the response evaluation based on metabolic tumor volume parameters to a histopathologic and clinical response evaluation (clinical response criteria: RECIST criteria = Response evaluation criteria in solid tumors, and WHO criteria = World health organization). Patients and methods: A total of 51 study subjects with adenocarcinomas (Type I due to Siewert classification) of the esophagus underwent PET-CT scans before and after neoadjuvant chemoradiotherapy. Tumor volume, maximum and mean standardized uptake values (SUV) were assessed before and after chemoradiotherapy. Furthermore, the total lesion glycolysis (TLG) was calculated by multiplying the tumor volume by the mean SUV of the volume. Clinical response evaluation was performed with endoscopic ultrasound and CT using RECIST and WHO criteria. The reference standard for treatment response was the postsurgical histopathology. Results: The decrease of tumor volume between the pre- and post-treatment PET-CT scans was a better predictor of histopathologic response and survival than the decrease of the SUV and of the clinical response evaluation based on RECIST and WHO criteria. The highest accuracy, however, was achieved when using the TLG for the identification of treatment responders. A decrease of the TLG by >78% between pre- and post-therapy scans predicted histopathologic response with a sensitivity and specificity of 91% and 93%, respectively. Conclusions: Tumor volume and TLG can be used to assess treatment response and survival in patients with esophageal adenocarcinoma

  19. SU-E-J-79: Internal Tumor Volume Motion and Volume Size Assessment Using 4D CT Lung Data

    Energy Technology Data Exchange (ETDEWEB)

    Jurkovic, I [University of Texas Health Science Center at San Antonio, San Antonio, TX (United States); Stathakis, S; Li, Y; Patel, A; Vincent, J; Papanikolaou, N; Mavroidis, P [Cancer Therapy and Research Center University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States)

    2014-06-01

    Purpose: To assess internal tumor volume change through breathing cycle and associated tumor motion using the 4DCT data. Methods: Respiration induced volume change through breathing cycle and associated motion was analyzed for nine patients that were scanned during the different respiratory phases. The examined datasets were the maximum and average intensity projections (MIP and AIP) and the 10 phases of the respiratory cycle. The internal target volume (ITV) was delineated on each of the phases and the planning target volume (PTV) was then created by adding setup margins to the ITV. Tumor motion through the phases was assessed using the acquired 4DCT dataset, which was then used to determine if the margins used for the ITV creation successfully encompassed the tumor in three dimensions. Results: Results showed that GTV motion along the superior inferior axes was the largest in all the cases independent of the tumor location and/or size or the use of abdomen compression. The extent of the tumor motion was found to be connected with the size of the GTV. The smallest GTVs exhibited largest motion vector independent of the tumor location. The motion vector size varied through the phases depending on the tumor size and location and it was smallest for phases 20 and 30. The smaller the volume of the delineated GTV, the greater its volume difference through the different respiratory phases was. The average GTV volume change was largest for the phases 60 and 70. Conclusion: Even if GTV is delineated using both AIP and MIP datasets, its motion extent will exceed the used margins especially for the very small GTV volumes. When the GTV size is less than 10 cc it is recommended to use fusion of the GTVs through all the phases to create the planning ITV.

  20. Computer Assisted Language Learning. Routledge Studies in Computer Assisted Language Learning

    Science.gov (United States)

    Pennington, Martha

    2011-01-01

    Computer-assisted language learning (CALL) is an approach to language teaching and learning in which computer technology is used as an aid to the presentation, reinforcement and assessment of material to be learned, usually including a substantial interactive element. This books provides an up-to date and comprehensive overview of…

  1. Predictive value of PET response combined with baseline metabolic tumor volume in peripheral T-cell lymphoma patients

    DEFF Research Database (Denmark)

    Cottereau, Anne-Segolene; El-Galaly, Tarec C; Becker, Stéphanie

    2018-01-01

    Peripheral T-cell lymphoma (PTCL) is a heterogeneous group of aggressive non-Hodgkin lymphomas with poor outcomes with current therapy. We investigated if response assessed with Positron Emission Tomography/computed tomography (PET/CT) combined with baseline total metabolic tumor volume (TMTV) co...

  2. Diversion Path Analysis handbook. Volume 3 (of 4 volumes). Computer Program 1

    International Nuclear Information System (INIS)

    Schleter, J.C.

    1978-11-01

    The FORTRAN IV computer program, DPA Computer Program 1 (DPACP-1), is used to assemble and tabulate the data for Specific Diversion Paths (SDPs) identified when performing a Diversion Path Analysis (DPA) in accord with the methodology given in Volume 1. The program requires 255498 bytes exclusive of the operating system. The data assembled and tabulated by DPACP-1 are used by the DPA team to assist in analyzing vulnerabilities, in a plant's material control and material accounting subsystems, to diversion of special nuclear material (SNM) by a knowledgable insider. Based on this analysis, the DPA team can identify, and propose to plant management, modifications to the plant's safeguards system that would eliminate, or reduce the severity of, the identified vulnerabilities. The data are also used by plant supervision when investigating a potential diversion

  3. Effects of Respiration-Averaged Computed Tomography on Positron Emission Tomography/Computed Tomography Quantification and its Potential Impact on Gross Tumor Volume Delineation

    International Nuclear Information System (INIS)

    Chi, Pai-Chun Melinda; Mawlawi, Osama; Luo Dershan; Liao Zhongxing; Macapinlac, Homer A.; Pan Tinsu

    2008-01-01

    Purpose: Patient respiratory motion can cause image artifacts in positron emission tomography (PET) from PET/computed tomography (CT) and change the quantification of PET for thoracic patients. In this study, respiration-averaged CT (ACT) was used to remove the artifacts, and the changes in standardized uptake value (SUV) and gross tumor volume (GTV) were quantified. Methods and Materials: We incorporated the ACT acquisition in a PET/CT session for 216 lung patients, generating two PET/CT data sets for each patient. The first data set (PET HCT /HCT) contained the clinical PET/CT in which PET was attenuation corrected with a helical CT (HCT). The second data set (PET ACT /ACT) contained the PET/CT in which PET was corrected with ACT. We quantified the differences between the two datasets in image alignment, maximum SUV (SUV max ), and GTV contours. Results: Of the patients, 68% demonstrated respiratory artifacts in the PET HCT , and for all patients the artifact was removed or reduced in the corresponding PET ACT . The impact of respiration artifact was the worst for lesions less than 50 cm 3 and located below the dome of the diaphragm. For lesions in this group, the mean SUV max difference, GTV volume change, shift in GTV centroid location, and concordance index were 21%, 154%, 2.4 mm, and 0.61, respectively. Conclusion: This study benchmarked the differences between the PET data with and without artifacts. It is important to pay attention to the potential existence of these artifacts during GTV contouring, as such artifacts may increase the uncertainties in the lesion volume and the centroid location

  4. Can visual assessment of blood flow patterns by dynamic contrast-enhanced computed tomography distinguish between malignant and benign lung tumors?

    DEFF Research Database (Denmark)

    Harders, Stefan Walbom; Madsen, Hans Henrik; Nellemann, Hanne Marie

    2017-01-01

    with suspected lung cancer and a lung tumor on their chest radiograph were included for DCE-CT. The tumors were categorized using structured qualitative analysis of tumor blood flow patterns. Histopathology was used as reference standard. RESULTS: Using structured qualitative analysis of tumor blood flow...... using structured qualitative analysis of tumor blood flow patterns is accurate as well as somewhat reproducible. However, there are significant limitations to DCE-CT.......BACKGROUND: Dynamic contrast-enhanced computed tomography (DCE-CT) is a tool, which, in theory, can quantify the blood flow and blood volume of tissues. In structured qualitative analysis, parametric color maps yield a visual impression of the blood flow and blood volume within the tissue being...

  5. Impact of Plasma Epstein-Barr Virus-DNA and Tumor Volume on Prognosis of Locally Advanced Nasopharyngeal Carcinoma

    Directory of Open Access Journals (Sweden)

    Meng Chen

    2015-01-01

    Full Text Available This retrospective study aims to examine the association of plasma Epstein-Barr virus- (EBV- DNA levels with the tumor volume and prognosis in patients with locally advanced nasopharyngeal carcinoma (NPC. A total of 165 patients with newly diagnosed locally advanced NPC were identified from September 2011 to July 2012. EBV-DNA was detected using fluorescence quantitative polymerase chain reaction (PCR amplification. The tumor volume was calculated by the systematic summation method of computer software. The median copy number of plasma EBV-DNA before treatment was 3790 copies/mL. The median gross tumor volume of the primary nasopharyngeal tumor (GTVnx, the lymph node lesions (GTVnd, and the total GTV before treatment were 72.46, 23.26, and 106.25 cm3, respectively; the EBV-DNA levels were significantly correlated with the GTVnd and the total GTV (P<0.01. The 2-year overall survival (OS rates in patients with positive and negative pretreatment plasma EBV-DNA were 100% and 98.4% (P=1.000, and the disease-free survival (DFS rates were 94.4% and 80.8% (P=0.044, respectively. These results indicate that high pretreatment plasma EBV-DNA levels in patients with locally advanced NPC are associated with the degree of lymph node metastasis, tumor burden, and poor prognosis.

  6. Bulletin bibliographique sur l'E.A.O. (l'enseignement assiste par ordinateur) (Bibliographic Bulletin on Computer Assisted Instruction). Publication K-4.

    Science.gov (United States)

    LaForge, Lorne, Ed.

    The bibliography contains about 150 citations of journal articles, monographs, collected works, research reports, and essays drawn from the BIBELO database and concerning computer-assisted language instruction. The first half of the volume is an annotated bibliography in alphabetical order by author. The second section contains subject and…

  7. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    Science.gov (United States)

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  8. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  9. Stereological quantification of tumor volume, mean nuclear volume and total number of melanoma cells correlated with morbidity and mortality

    DEFF Research Database (Denmark)

    Bønnelykke-Behrndtz, Marie Louise; Sørensen, Flemming Brandt; Damsgaard, Tine Engberg

    2008-01-01

    potential indicators of prognosis. Sixty patients who underwent surgery at the Department of Plastic Surgery, Aarhus University Hospital, from 1991 to 1994 were included in the study. Total tumor volume was estimated by the Cavalieri technique, total number of tumor cells by the optical dissector principle...... showed a significant impact on both disease-free survival (p=0.001) and mortality (p=0.009). In conclusion, tumor volume and total number of cancer cells were highly reproducible but did not add additional, independent prognostic information regarding the study population.......Stereological quantification of tumor volume, total number of tumor cells and mean nuclear volume provides unbiased data, regardless of the three-dimensional shape of the melanocytic lesion. The aim of the present study was to investigate whether these variables are reproducible and may represent...

  10. The impact of computed tomography slice thickness on the assessment of stereotactic, 3D conformal and intensity-modulated radiotherapy of brain tumors.

    Science.gov (United States)

    Caivano, R; Fiorentino, A; Pedicini, P; Califano, G; Fusco, V

    2014-05-01

    To evaluate radiotherapy treatment planning accuracy by varying computed tomography (CT) slice thickness and tumor size. CT datasets from patients with primary brain disease and metastatic brain disease were selected. Tumor volumes ranging from about 2.5 to 100 cc and CT scan at different slice thicknesses (1, 2, 4, 6 and 10 mm) were used to perform treatment planning (1-, 2-, 4-, 6- and 10-CT, respectively). For any slice thickness, a conformity index (CI) referring to 100, 98, 95 and 90 % isodoses and tumor size was computed. All the CI and volumes obtained were compared to evaluate the impact of CT slice thickness on treatment plans. The smallest volumes reduce significantly if defined on 1-CT with respect to 4- and 6-CT, while the CT slice thickness does not affect target definition for the largest volumes. The mean CI for all the considered isodoses and CT slice thickness shows no statistical differences when 1-CT is compared to 2-CT. Comparing the mean CI of 1- with 4-CT and 1- with 6-CT, statistical differences appear only for the smallest volumes with respect to 100, 98 and 95 % isodoses-the CI for 90 % isodose being not statistically significant for all the considered PTVs. The accuracy of radiotherapy tumor volume definition depends on CT slice thickness. To achieve a better tumor definition and dose coverage, 1- and 2-CT would be suitable for small targets, while 4- and 6-CT are suitable for the other volumes.

  11. SU-F-R-42: Association of Radiomic and Metabolic Tumor Volumes in Radiation Treatment of Glioblastoma Multiforme

    International Nuclear Information System (INIS)

    Lopez, C; Nagornaya, N; Parra, N; Kwon, D; Ishkanian, F; Markoe, A; Maudsley, A; Stoyanova, R

    2016-01-01

    Purpose: High-throughput extraction of imaging and metabolomic quantitative features from MRI and MR Spectroscopy Imaging (MRSI) of Glioblastoma Multiforme (GBM) results in tens of variables per patient. In radiotherapy (RT) of GBM, the relevant metabolic tumor volumes (MTVs) are related to aberrant levels of N-acetyl Aspartate (NAA) and Choline (Cho). Corresponding Clinical Target Volumes (CTVs) for RT planning are based on Contrast Enhancing T1-weighted MRI (CE-T1w) and T2-weighted/Fluid Attenuated Inversion Recovery (FLAIR) MRI. The objective is to build a framework for investigation of associations between imaging, CTV, and MTV features better understanding of the underlying information in the CTVs and dependencies between these volumes. Methods: Necrotic portions, enhancing lesion and edema were manually contoured on T1w/T2w images for 17 GBM patients. CTVs and MTVs for NAA (MTV NAA ) and Cho (MTV Cho ) were constructed. Tumors were scored categorically for ten semantic imaging traits by neuroradiologist. All features were investigated for redundancy. Two-way correlations between imaging and RT/MTV features were visualized as heat maps. Associations between MTV NAA , MTV Cho and imaging features were studied using Spearman correlation. Results: 39 imaging features were computed per patient. Half of the imaging traits were replaced with automatically extracted continuous variables. 21 features were extracted from MTVs/CTVs. There were a high number (43) of significant correlations of imaging with CTVs/MTV NAA while very few (10) significant correlations were with CTVs/MTV Cho . MTV NAA was found to be closely associated with MRI volumes, MTV Cho remains elusive for characterization with imaging. Conclusion: A framework for investigation of co-dependency between MRI and RT/metabolic features is established. A series of semantic imaging traits were replaced with automatically extracted continuous variables. The approach will allow for exploration of relationships

  12. SU-F-R-42: Association of Radiomic and Metabolic Tumor Volumes in Radiation Treatment of Glioblastoma Multiforme

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, C; Nagornaya, N; Parra, N; Kwon, D; Ishkanian, F; Markoe, A; Maudsley, A; Stoyanova, R [University of Miami, Miami, Florida (United States)

    2016-06-15

    Purpose: High-throughput extraction of imaging and metabolomic quantitative features from MRI and MR Spectroscopy Imaging (MRSI) of Glioblastoma Multiforme (GBM) results in tens of variables per patient. In radiotherapy (RT) of GBM, the relevant metabolic tumor volumes (MTVs) are related to aberrant levels of N-acetyl Aspartate (NAA) and Choline (Cho). Corresponding Clinical Target Volumes (CTVs) for RT planning are based on Contrast Enhancing T1-weighted MRI (CE-T1w) and T2-weighted/Fluid Attenuated Inversion Recovery (FLAIR) MRI. The objective is to build a framework for investigation of associations between imaging, CTV, and MTV features better understanding of the underlying information in the CTVs and dependencies between these volumes. Methods: Necrotic portions, enhancing lesion and edema were manually contoured on T1w/T2w images for 17 GBM patients. CTVs and MTVs for NAA (MTV{sub NAA}) and Cho (MTV{sub Cho}) were constructed. Tumors were scored categorically for ten semantic imaging traits by neuroradiologist. All features were investigated for redundancy. Two-way correlations between imaging and RT/MTV features were visualized as heat maps. Associations between MTV{sub NAA}, MTV{sub Cho} and imaging features were studied using Spearman correlation. Results: 39 imaging features were computed per patient. Half of the imaging traits were replaced with automatically extracted continuous variables. 21 features were extracted from MTVs/CTVs. There were a high number (43) of significant correlations of imaging with CTVs/MTV{sub NAA} while very few (10) significant correlations were with CTVs/MTV{sub Cho}. MTV{sub NAA} was found to be closely associated with MRI volumes, MTV{sub Cho} remains elusive for characterization with imaging. Conclusion: A framework for investigation of co-dependency between MRI and RT/metabolic features is established. A series of semantic imaging traits were replaced with automatically extracted continuous variables. The approach will

  13. Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Nan-Jie [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Wong, Chun-Sing, E-mail: drcswong@gmail.com [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chu, Yiu-Ching [Department of Radiology, Kwong Wah Hospital, Hong Kong (China); Guo, Hua [Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing (China); Huang, Bingsheng [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chan, Queenie [Philips Healthcare, Hong Kong (China)

    2013-10-01

    Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

  14. Computer Assisted Instruction

    Science.gov (United States)

    Higgins, Paul

    1976-01-01

    Methodology for developing a computer assisted instruction (CAI) lesson (scripting, programing, and testing) is reviewed. A project done by Informatics Education Ltd. (IEL) for the Department of National Defense (DND) is used as an example. (JT)

  15. Tumor Volume Estimation and Quasi-Continuous Administration for Most Effective Bevacizumab Therapy.

    Science.gov (United States)

    Sápi, Johanna; Kovács, Levente; Drexler, Dániel András; Kocsis, Pál; Gajári, Dávid; Sápi, Zoltán

    2015-01-01

    Bevacizumab is an exogenous inhibitor which inhibits the biological activity of human VEGF. Several studies have investigated the effectiveness of bevacizumab therapy according to different cancer types but these days there is an intense debate on its utility. We have investigated different methods to find the best tumor volume estimation since it creates the possibility for precise and effective drug administration with a much lower dose than in the protocol. We have examined C38 mouse colon adenocarcinoma and HT-29 human colorectal adenocarcinoma. In both cases, three groups were compared in the experiments. The first group did not receive therapy, the second group received one 200 μg bevacizumab dose for a treatment period (protocol-based therapy), and the third group received 1.1 μg bevacizumab every day (quasi-continuous therapy). Tumor volume measurement was performed by digital caliper and small animal MRI. The mathematical relationship between MRI-measured tumor volume and mass was investigated to estimate accurate tumor volume using caliper-measured data. A two-dimensional mathematical model was applied for tumor volume evaluation, and tumor- and therapy-specific constants were calculated for the three different groups. The effectiveness of bevacizumab administration was examined by statistical analysis. In the case of C38 adenocarcinoma, protocol-based treatment did not result in significantly smaller tumor volume compared to the no treatment group; however, there was a significant difference between untreated mice and mice who received quasi-continuous therapy (p = 0.002). In the case of HT-29 adenocarcinoma, the daily treatment with one-twelfth total dose resulted in significantly smaller tumors than the protocol-based treatment (p = 0.038). When the tumor has a symmetrical, solid closed shape (typically without treatment), volume can be evaluated accurately from caliper-measured data with the applied two-dimensional mathematical model. Our results

  16. Computer assisted radiology and surgery. CARS 2010

    International Nuclear Information System (INIS)

    Anon.

    2010-01-01

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  17. Computer assisted radiology and surgery. CARS 2010

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-06-15

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  18. Primary Tumor Volume Is an Important Predictor of Clinical Outcomes Among Patients With Locally Advanced Squamous Cell Cancer of the Head and Neck Treated With Definitive Chemoradiotherapy

    International Nuclear Information System (INIS)

    Strongin, Anna; Yovino, Susannah; Taylor, Rodney; Wolf, Jeffrey; Cullen, Kevin; Zimrin, Ann; Strome, Scott; Regine, William; Suntharalingam, Mohan

    2012-01-01

    Purpose: The tumor volume has been established as a significant predictor of outcomes among patients with head-and-neck cancer undergoing radiotherapy alone. The present study attempted to add to the existing data on tumor volume as a prognostic factor among patients undergoing chemoradiotherapy. Methods and Materials: A total of 78 patients who had undergone definitive chemoradiotherapy for Stage III-IV squamous cell cancer of the hypopharynx, oropharynx, and larynx were identified. The primary tumor volumes were calculated from the treatment planning computed tomography scans, and these were correlated to the survival and tumor control data obtained from the retrospective analysis. Results: The interval to progression correlated with the primary tumor volume (p = .007). The critical cutoff point for the tumor volume was identified as 35 cm 3 , and patients with a tumor volume 3 had a significantly better prognosis than those with a tumor volume >35 cm 3 at 5 years (43% vs. 71%, p = .010). Longer survival was also correlated with smaller primary tumor volumes (p = .022). Similarly, patients with a primary tumor volume 3 had a better prognosis in terms of both progression-free survival (61% vs. 33%, p = .004) and overall survival (84% vs. 41%, p = 3 larger than tumors without locoregional failure (p = .028) and 27.1-cm 3 larger than tumors that recurred as distant metastases (p = .020). Conclusion: The results of our study have shown that the primary tumor volume is a significant prognostic factor in patients with advanced cancer of the head and neck undergoing definitive chemoradiotherapy and correlated with the treatment outcomes better than the T or N stage.

  19. Endoscopic clipping for gastrointestinal tumors. A method to define the target volume more precisely

    International Nuclear Information System (INIS)

    Riepl, M.; Klautke, G.; Fehr, R.; Fietkau, R.; Pietsch, A.

    2000-01-01

    Background: In many cases it is not possible to exactly define the extension of carcinoma of the gastrointestinal tract with the help of computertomography scans made for 3-D-radiation treatment planning. Consequently, the planning of external beam radiotherapy is made more difficult for the gross tumor volume as well as, in some cases, also for the clinical target volume. Patients and Methods: Eleven patients with macrosocpic tumors (rectal cancer n = 5, cardiac cancer n = 6) were included. Just before 3-D planning, the oral and aboral border of the tumor was marked endoscopically with hemoclips. Subsequently, CT scans for radiotherapy planning were made and the clinical target volume was defined. Five to 6 weeks thereafter, new CT scans were done to define the gross tumor volume for boost planning. Two investigators independently assessed the influence of the hemoclips on the different planning volumes, and whether the number of clips was sufficient to define the gross tumor volume. Results: In all patients, the implantation of the clips was done without complications. Start of radiotherapy was not delayed. With the help of the clips it was possible to exactly define the position and the extension of the primary tumor. The clinical target volume was modified according to the position of the clips in 5/11 patients; the gross tumor volume was modified in 7/11 patients. The use of the clips made the documentation and verification of the treatment portals by the simulator easier. Moreover, the clips helped the surgeon to define the primary tumor region following marked regression after neoadjuvant therapy in 3 patients. Conclusions: Endoscopic clipping of gastrointestinal tumors helps to define the tumor volumes more precisely in radiation therapy. The clips are easily recognized on the portal films and, thus, contribute to quality control. (orig.) [de

  20. Lung Volume Reduction After Stereotactic Ablative Radiation Therapy of Lung Tumors: Potential Application to Emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Binkley, Michael S. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Shrager, Joseph B. [Division of Thoracic Surgery, Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Leung, Ann N. [Department of Radiology, Stanford University School of Medicine, Stanford, California (United States); Popat, Rita [Department of Health Research and Policy, Stanford University School of Medicine, Stanford, California (United States); Trakul, Nicholas [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Department of Radiation Oncology, University of Southern California Keck School of Medicine, Los Angeles, California (United States); Atwood, Todd F.; Chaudhuri, Aadel [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Diehn, Maximilian, E-mail: Diehn@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Institute for Stem Cell Biology and Regenerative Medicine, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2014-09-01

    Purpose: Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema. Methods and Materials: We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and ≥6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABR and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, α/β = 3). Results: 27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade ≥3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, −0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, −3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED ≥60 Gy (r{sup 2}=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r{sup 2}=0.47, P<.0001). Conclusions: We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across

  1. Comparison of conventional and 3-dimensional computed tomography against histopathologic examination in determining pancreatic adenocarcinoma tumor size: Implications for radiation therapy planning

    International Nuclear Information System (INIS)

    Qiu Haoming; Wild, Aaron T.; Wang Hao; Fishman, Elliot K.; Hruban, Ralph H.; Laheru, Daniel A.; Kumar, Rachit; Hacker-Prietz, Amy; Tuli, Richard; Tryggestad, Erik; Schulick, Richard D.; Cameron, John L.; Edil, Barish H.; Pawlik, Timothy M.; Wolfgang, Christopher L.; Herman, Joseph M.

    2012-01-01

    Background and purpose: This study seeks to: (a) quantify radiologic-pathologic discrepancy for pancreatic adenocarcinoma by comparing tumor size on conventional computed tomography (C-CT) and 3-dimensional CT (3D-CT) to corresponding pathologic specimens; and (b) to identify clinico-pathologic characteristics predictive of radiologic-pathologic discrepancy to assist radiotherapy planning. Materials and methods: Sixty-three patients with pancreatic adenocarcinoma and preoperative C-CT and volume-rendered 3D-CT imaging within 6 weeks of resection were identified. Maximum tumor diameter (MTD) was measured on pathology, C-CT, and 3D-CT and compared for each patient as well as among different clinico-pathologic subgroups. Results: There was a trend toward C-CT underestimation of MTD compared to final pathology (p = 0.08), but no significant difference between 3D-CT MTD and pathology (p = 0.54). Pathologic tumor size was significantly underestimated by C-CT in patients with larger pathologic tumor size (>3.0 cm, p = 0.0001), smaller tumor size on C-CT ( 90 U/mL, p = 0.008), and location in the pancreatic head (p = 0.015). A model for predicting pathologic MTD using C-CT MTD and CA19-9 level was generated. Conclusions: 3D-CT may allow for more accurate contouring of pancreatic tumors than C-CT. Patients with the above clinico-pathologic characteristics may require expanded margins relative to tumor size estimates on C-CT during radiotherapy planning.

  2. [Computer-assisted temporomandibular joint reconstruction.

    Science.gov (United States)

    Zwetyenga, N; Mommers, X-A; Cheynet, F

    2013-08-02

    Prosthetic replacement of TMJ is gradually becoming a common procedure because of good functional and aesthetic results and low morbidity. Prosthetic models available can be standard or custom-made. Custom-made prosthesis are usually reserved for complex cases, but we think that computer assistance for custom-made prosthesis should be indicated for each case because it gives a greater implant stability and fewer complications. Computer assistance will further enlarge TMJ prosthesis replacement indications. Copyright © 2013. Published by Elsevier Masson SAS.

  3. MR imaging assisted radiation therapy planning of brain tumors

    International Nuclear Information System (INIS)

    Just, M.; Roesler, H.P.; Higer, H.P.; Kutzner, J.; Thelen, M.

    1990-01-01

    This paper reports on the improvement of the accuracy of treatment portals in radiation therapy of brain tumors with use of MR imaging. After proper processing, the parasagittal MR image showing the largest tumor size and the midline sagittal image were superimposed. With common anatomic landmarks of midline tomogram and lateral simulation radiograph, commensurate reference grids were laid over both images in identical positions. Tumor coordinates were then transferred from the synthesized MR image to the lateral radiograph. Rectangular fields or individual shielding blocks encompassing the tumor could be drawn directly. This new method was used in 17 patients, and results were compared with CT-assisted results

  4. Early Childhood Teacher Candidates\\' Attitudes towards Computer and Computer Assisted Instruction

    OpenAIRE

    Oğuz, Evrim; Ellez, A. Murat; Akamca, Güzin Özyılmaz; Kesercioğlu, Teoman İ.; Girgin, Günseli

    2011-01-01

    The aim of this research is to evaluate preschool candidates’ attitudes towards computers andattitudes towards use of computer assisted instruction. The sample of this study includes 481 early childhoodeducation students who attended Dokuz Eylül University’s department of Early Childhood Education. Data werecollected by using “Scale of Computer Assisted Instruction Attitudes” developed by the Arslan (2006),“Computer Attitudes Scale” developed by Çelik & Bindak (2005) and “General Info...

  5. Whole-tumor histogram analysis of the cerebral blood volume map: tumor volume defined by 11C-methionine positron emission tomography image improves the diagnostic accuracy of cerebral glioma grading.

    Science.gov (United States)

    Wu, Rongli; Watanabe, Yoshiyuki; Arisawa, Atsuko; Takahashi, Hiroto; Tanaka, Hisashi; Fujimoto, Yasunori; Watabe, Tadashi; Isohashi, Kayako; Hatazawa, Jun; Tomiyama, Noriyuki

    2017-10-01

    This study aimed to compare the tumor volume definition using conventional magnetic resonance (MR) and 11C-methionine positron emission tomography (MET/PET) images in the differentiation of the pre-operative glioma grade by using whole-tumor histogram analysis of normalized cerebral blood volume (nCBV) maps. Thirty-four patients with histopathologically proven primary brain low-grade gliomas (n = 15) and high-grade gliomas (n = 19) underwent pre-operative or pre-biopsy MET/PET, fluid-attenuated inversion recovery, dynamic susceptibility contrast perfusion-weighted magnetic resonance imaging, and contrast-enhanced T1-weighted at 3.0 T. The histogram distribution derived from the nCBV maps was obtained by co-registering the whole tumor volume delineated on conventional MR or MET/PET images, and eight histogram parameters were assessed. The mean nCBV value had the highest AUC value (0.906) based on MET/PET images. Diagnostic accuracy significantly improved when the tumor volume was measured from MET/PET images compared with conventional MR images for the parameters of mean, 50th, and 75th percentile nCBV value (p = 0.0246, 0.0223, and 0.0150, respectively). Whole-tumor histogram analysis of CBV map provides more valuable histogram parameters and increases diagnostic accuracy in the differentiation of pre-operative cerebral gliomas when the tumor volume is derived from MET/PET images.

  6. Natural Computing in Computational Finance Volume 4

    CERN Document Server

    O’Neill, Michael; Maringer, Dietmar

    2012-01-01

    This book follows on from Natural Computing in Computational Finance  Volumes I, II and III.   As in the previous volumes of this series, the  book consists of a series of  chapters each of  which was selected following a rigorous, peer-reviewed, selection process.  The chapters illustrate the application of a range of cutting-edge natural  computing and agent-based methodologies in computational finance and economics.  The applications explored include  option model calibration, financial trend reversal detection, enhanced indexation, algorithmic trading,  corporate payout determination and agent-based modeling of liquidity costs, and trade strategy adaptation.  While describing cutting edge applications, the chapters are  written so that they are accessible to a wide audience. Hence, they should be of interest  to academics, students and practitioners in the fields of computational finance and  economics.  

  7. Effects of computer-assisted oral anticoagulant therapy

    DEFF Research Database (Denmark)

    Rasmussen, Rune Skovgaard; Corell, Pernille; Madsen, Poul

    2012-01-01

    : Patients randomized to computer-assisted anticoagulation and the CoaguChek® system reached the therapeutic target range after 8 days compared to 14 days by prescriptions from physicians (p = 0.04). Time spent in the therapeutic target range did not differ between groups. The median INR value measured...... prescribed by physicians, and the total time spent within the therapeutic target range was similar. Thus computer-assisted oral anticoagulant therapy may reduce the cost of anticoagulation therapy without lowering the quality. INR values measured by CoaguChek® were reliable compared to measurements......UNLABELLED: BACKGROUND: Computer-assistance and self-monitoring lower the cost and may improve the quality of anticoagulation therapy. The main purpose of this clinical investigation was to use computer-assisted oral anticoagulant therapy to improve the time to reach and the time spent within...

  8. SU-E-I-83: Error Analysis of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using a Preclinical Multi-Modality QA Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y [University of Kansas Hospital, Kansas City, KS (United States); Fullerton, G; Goins, B [University of Texas Health Science Center at San Antonio, San Antonio, TX (United States)

    2015-06-15

    Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group; 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement

  9. Comparison of imaging-based gross tumor volume and pathological volume determined by whole-mount serial sections in primary cervical cancer

    Directory of Open Access Journals (Sweden)

    Zhang Y

    2013-07-01

    Full Text Available Ying Zhang,1,* Jing Hu,1,* Jianping Li,1 Ning Wang,1 Weiwei Li,1 Yongchun Zhou,1 Junyue Liu,1 Lichun Wei,1 Mei Shi,1 Shengjun Wang,2 Jing Wang,2 Xia Li,3 Wanling Ma4 1Department of Radiation Oncology, 2Department of Nuclear Medicine, 3Department of Pathology, 4Department of Radiology, Xijing Hospital, Xi'an, People's Republic of China*These authors contributed equally to this workObjective: To investigate the accuracy of imaging-based gross tumor volume (GTV compared with pathological volume in cervical cancer.Methods: Ten patients with International Federation of Gynecology and Obstetrics stage I–II cervical cancer were eligible for investigation and underwent surgery in this study. Magnetic resonance imaging (MRI and fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET/computed tomography (CT scans were taken the day before surgery. The GTVs under MRI and 18F-FDG PET/CT (GTV-MRI, GTV-PET, GTV-CT were calculated automatically by Eclipse treatment-planning systems. Specimens of excised uterine cervix and cervical cancer were consecutively sliced and divided into whole-mount serial sections. The tumor border of hematoxylin and eosin-stained sections was outlined under a microscope by an experienced pathologist. GTV through pathological image (GTV-path was calculated with Adobe Photoshop.Results: The GTVs (average ± standard deviation delineated and calculated under CT, MRI, PET, and histopathological sections were 19.41 ± 11.96 cm3, 12.66 ± 10.53 cm3, 11.07 ± 9.44 cm3, and 10.79 ± 8.71 cm3, respectively. The volume of GTV-CT or GTV-MR was bigger than GTV-path, and the difference was statistically significant (P 0.05. Spearman correlation analysis showed that GTV-CT, GTV-MRI, and GTV-PET were significantly correlated with GTV-path (P < 0.01. There was no significant difference in the lesion coverage factor among the three modalities.Conclusion: The present study showed that GTV defined under 40% of maximum standardized

  10. Estimation of tumor volume and its prognostic significance to study the biological behavior of carcinoma of cervix

    Directory of Open Access Journals (Sweden)

    Leelavathi Dawson

    2016-01-01

    Results: The median age of the patients in this group was 47.5 years, with a range of 30–80 years. The major histological type of carcinoma among 40 cases is squamous cell carcinoma (SCC (in 90% of cases, and 10% had adenocarcinoma. Pathological staging of the carcinoma cervix showed stage Ib, IIa, IIb, and IVa (35%, 20%, 40%, and 5%. Tumor volume estimated on pathological specimens of 40 cases ranged from 230 cumm to 49,760 cumm with a mean of 14,844 cumm. 12 (30% cases had tumor volume more than 15,000 cumm, 12 (30% cases had tumor volume <5000 cumm and 16 (40% cases had tumor volume between 5000 and 15,000 cumm. 17% of the tumors with tumor volume <5000 cumm showed lymph node metastases, whereas 67% (out of 12cases of cases with tumor volume more than 15,000 cumm showed lymph node metastases. 67% of the tumors with tumor volume <5000 cumm showed 0/4 organs involvement, whereas all cases with tumor volume more than 15,000 cumm showed more than one organ involvement among vagina, uterus, parametrium or bladder/rectum. Fibronectin positivity was seen in 22 out of 44 cases (55%. Macrophages were seen surrounding the group of tumor cells by LN5 immunostaining. Conclusion: Tumor volume can be considered as an independent prognostic factor to assess the spread of the tumor. Cases with tumor volume <5000 cumm show low risk in terms of parametrial involvement and lymph node metastasis and those with tumor volume more than 15,000 cumm showed more organ spread. Fibronectin positivity carries some importance in low-risk cases. For macrophages, further detailed study needs to be carried out.

  11. Tumor Volume Reduction Rate After Preoperative Chemoradiotherapy as a Prognostic Factor in Locally Advanced Rectal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yeo, Seung-Gu [Center for Colorectal Cancer, Research Institute and Hospital, National Cancer Center, Goyang (Korea, Republic of); Department of Radiation Oncology, Soonchunhyang University College of Medicine, Cheonan (Korea, Republic of); Kim, Dae Yong, E-mail: radiopiakim@hanmail.net [Center for Colorectal Cancer, Research Institute and Hospital, National Cancer Center, Goyang (Korea, Republic of); Park, Ji Won; Oh, Jae Hwan; Kim, Sun Young; Chang, Hee Jin; Kim, Tae Hyun; Kim, Byung Chang; Sohn, Dae Kyung; Kim, Min Ju [Center for Colorectal Cancer, Research Institute and Hospital, National Cancer Center, Goyang (Korea, Republic of)

    2012-02-01

    Purpose: To investigate the prognostic significance of tumor volume reduction rate (TVRR) after preoperative chemoradiotherapy (CRT) in locally advanced rectal cancer (LARC). Methods and Materials: In total, 430 primary LARC (cT3-4) patients who were treated with preoperative CRT and curative radical surgery between May 2002 and March 2008 were analyzed retrospectively. Pre- and post-CRT tumor volumes were measured using three-dimensional region-of-interest MR volumetry. Tumor volume reduction rate was determined using the equation TVRR (%) = (pre-CRT tumor volume - post-CRT tumor volume) Multiplication-Sign 100/pre-CRT tumor volume. The median follow-up period was 64 months (range, 27-99 months) for survivors. Endpoints were disease-free survival (DFS) and overall survival (OS). Results: The median TVRR was 70.2% (mean, 64.7% {+-} 22.6%; range, 0-100%). Downstaging (ypT0-2N0M0) occurred in 183 patients (42.6%). The 5-year DFS and OS rates were 77.7% and 86.3%, respectively. In the analysis that included pre-CRT and post-CRT tumor volumes and TVRR as continuous variables, only TVRR was an independent prognostic factor. Tumor volume reduction rate was categorized according to a cutoff value of 45% and included with clinicopathologic factors in the multivariate analysis; ypN status, circumferential resection margin, and TVRR were significant prognostic factors for both DFS and OS. Conclusions: Tumor volume reduction rate was a significant prognostic factor in LARC patients receiving preoperative CRT. Tumor volume reduction rate data may be useful for tailoring surgery and postoperative adjuvant therapy after preoperative CRT.

  12. Calculating the tumor volume of acoustic neuromas: comparison of ABC/2 formula with planimetry method.

    Science.gov (United States)

    Yu, Yi-Lin; Lee, Meei-Shyuan; Juan, Chun-Jung; Hueng, Dueng-Yuan

    2013-08-01

    The ABC/2 equation is commonly applied to measure the volume of intracranial hematoma. However, the precision of ABC/2 equation in estimating the tumor volume of acoustic neuromas is less addressed. The study is to evaluate the accuracy of the ABC/2 formula by comparing with planimetry method for estimating the tumor volumes. Thirty-two patients diagnosed with acoustic neuroma received contrast-enhanced magnetic resonance imaging of brain were recruited. The volume was calculated by the ABC/2 equation and planimetry method (defined as exact volume) at the same time. The 32 patients were divided into three groups by tumor volume to avoid volume-dependent overestimation (6 ml). The tumor volume by ABC/2 method was highly correlated to that calculated by planimetry method using linear regression analysis (R2=0.985). Pearson correlation coefficient (r=0.993, pABC/2 formula is an easy method in estimating the tumor volume of acoustic neuromas that is not inferior to planimetry method. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Three-dimensional segmentation of the tumor mass in computed tomographic images of neuroblastoma

    Science.gov (United States)

    Deglint, Hanford J.; Rangayyan, Rangaraj M.; Boag, Graham S.

    2004-05-01

    Tumor definition and diagnosis require the analysis of the spatial distribution and Hounsfield unit (HU) values of voxels in computed tomography (CT) images, coupled with a knowledge of normal anatomy. Segmentation of the tumor in neuroblastoma is complicated by the fact that the mass is almost always heterogeneous in nature; furthermore, viable tumor, necrosis, fibrosis, and normal tissue are often intermixed. Rather than attempt to separate these tissue types into distinct regions, we propose to explore methods to delineate the normal structures expected in abdominal CT images, remove them from further consideration, and examine the remaining parts of the images for the tumor mass. We explore the use of fuzzy connectivity for this purpose. Expert knowledge provided by the radiologist in the form of the expected structures and their shapes, HU values, and radiological characteristics are also incorporated in the segmentation algorithm. Segmentation and analysis of the tissue composition of the tumor can assist in quantitative assessment of the response to chemotherapy and in the planning of delayed surgery for resection of the tumor. The performance of the algorithm is evaluated using cases acquired from the Alberta Children's Hospital.

  14. Computer-Assisted Linguistic Analysis of the Peshitta

    NARCIS (Netherlands)

    Roorda, D.; Talstra, Eep; Dyk, Janet; van Keulen, Percy; Sikkel, Constantijn; Bosman, H.J.; Jenner, K.D.; Bakker, Dirk; Volkmer, J.A.; Gutman, Ariel; van Peursen, Wido Th.

    2014-01-01

    CALAP (Computer-Assisted Linguistic Analysis of the Peshitta), a joint research project of the Peshitta Institute Leiden and the Werkgroep Informatica at the Vrije Universiteit Amsterdam (1999-2005) CALAP concerned the computer-assisted analysis of the Peshitta to Kings (Janet Dyk and Percy van

  15. Dosimetric Advantages of Four-Dimensional Adaptive Image-Guided Radiotherapy for Lung Tumors Using Online Cone-Beam Computed Tomography

    International Nuclear Information System (INIS)

    Harsolia, Asif; Hugo, Geoffrey D.; Kestin, Larry L.; Grills, Inga S.; Yan Di

    2008-01-01

    Purpose: This study compares multiple planning techniques designed to improve accuracy while allowing reduced planning target volume (PTV) margins though image-guided radiotherapy (IGRT) with four-dimensional (4D) cone-beam computed tomography (CBCT). Methods and Materials: Free-breathing planning and 4D-CBCT scans were obtained in 8 patients with lung tumors. Four plans were generated for each patient: 3D-conformal, 4D-union, 4D-offline adaptive with a single correction (offline ART), and 4D-online adaptive with daily correction (online ART). For the 4D-union plan, the union of gross tumor volumes from all phases of the 4D-CBCT was created with a 5-mm expansion applied for setup uncertainty. For offline and online ART, the gross tumor volume was delineated at the mean position of tumor motion from the 4D-CBCT. The PTV margins were calculated from the random components of tumor motion and setup uncertainty. Results: Adaptive IGRT techniques provided better PTV coverage with less irradiated normal tissues. Compared with 3D plans, mean relative decreases in PTV volumes were 15%, 39%, and 44% using 4D-union, offline ART, and online ART planning techniques, respectively. This resulted in mean lung volume receiving ≥ 20Gy (V20) relative decreases of 21%, 23%, and 31% and mean lung dose relative decreases of 16%, 26%, and 31% for the 4D-union, 4D-offline ART, and 4D-online ART, respectively. Conclusions: Adaptive IGRT using CBCT is feasible for the treatment of patients with lung tumors and significantly decreases PTV volume and dose to normal tissues, allowing for the possibility of dose escalation. All analyzed 4D planning strategies resulted in improvements over 3D plans, with 4D-online ART appearing optimal

  16. A simple, quantitative method using alginate gel to determine rat colonic tumor volume in vivo.

    Science.gov (United States)

    Irving, Amy A; Young, Lindsay B; Pleiman, Jennifer K; Konrath, Michael J; Marzella, Blake; Nonte, Michael; Cacciatore, Justin; Ford, Madeline R; Clipson, Linda; Amos-Landgraf, James M; Dove, William F

    2014-04-01

    Many studies of the response of colonic tumors to therapeutics use tumor multiplicity as the endpoint to determine the effectiveness of the agent. These studies can be greatly enhanced by accurate measurements of tumor volume. Here we present a quantitative method to easily and accurately determine colonic tumor volume. This approach uses a biocompatible alginate to create a negative mold of a tumor-bearing colon; this mold is then used to make positive casts of dental stone that replicate the shape of each original tumor. The weight of the dental stone cast correlates highly with the weight of the dissected tumors. After refinement of the technique, overall error in tumor volume was 16.9% ± 7.9% and includes error from both the alginate and dental stone procedures. Because this technique is limited to molding of tumors in the colon, we utilized the Apc(Pirc/+) rat, which has a propensity for developing colonic tumors that reflect the location of the majority of human intestinal tumors. We have successfully used the described method to determine tumor volumes ranging from 4 to 196 mm³. Alginate molding combined with dental stone casting is a facile method for determining tumor volume in vivo without costly equipment or knowledge of analytic software. This broadly accessible method creates the opportunity to objectively study colonic tumors over time in living animals in conjunction with other experiments and without transferring animals from the facility where they are maintained.

  17. Computer Assisted Advising Tool (CAAT).

    Science.gov (United States)

    Matsen, Marie E.

    Lane Community College's Computer Assisted Advising Tool (CAAT) is used by counselors to assist students in developing a plan for the completion of a degree or certificate. CAAT was designed to facilitate student advisement from matriculation to graduation by comparing degree requirements with the courses completed by students. Three major sources…

  18. Comparison of Rigid and Adaptive Methods of Propagating Gross Tumor Volume Through Respiratory Phases of Four-Dimensional Computed Tomography Image Data Set

    International Nuclear Information System (INIS)

    Ezhil, Muthuveni; Choi, Bum; Starkschall, George; Bucci, M. Kara; Vedam, Sastry; Balter, Peter

    2008-01-01

    Purpose: To compare three different methods of propagating the gross tumor volume (GTV) through the respiratory phases that constitute a four-dimensional computed tomography image data set. Methods and Materials: Four-dimensional computed tomography data sets of 20 patients who had undergone definitive hypofractionated radiotherapy to the lung were acquired. The GTV regions of interest (ROIs) were manually delineated on each phase of the four-dimensional computed tomography data set. The ROI from the end-expiration phase was propagated to the remaining nine phases of respiration using the following three techniques: (1) rigid-image registration using in-house software, (2) rigid image registration using research software from a commercial radiotherapy planning system vendor, and (3) rigid-image registration followed by deformable adaptation originally intended for organ-at-risk delineation using the same software. The internal GTVs generated from the various propagation methods were compared with the manual internal GTV using the normalized Dice similarity coefficient (DSC) index. Results: The normalized DSC index of 1.01 ± 0.06 (SD) for rigid propagation using the in-house software program was identical to the normalized DSC index of 1.01 ± 0.06 for rigid propagation achieved with the vendor's research software. Adaptive propagation yielded poorer results, with a normalized DSC index of 0.89 ± 0.10 (paired t test, p <0.001). Conclusion: Propagation of the GTV ROIs through the respiratory phases using rigid- body registration is an acceptable method within a 1-mm margin of uncertainty. The adaptive organ-at-risk propagation method was not applicable to propagating GTV ROIs, resulting in an unacceptable reduction of the volume and distortion of the ROIs

  19. Outcomes of Orbital Floor Reconstruction After Extensive Maxillectomy Using the Computer-Assisted Fabricated Individual Titanium Mesh Technique.

    Science.gov (United States)

    Zhang, Wen-Bo; Mao, Chi; Liu, Xiao-Jing; Guo, Chuan-Bin; Yu, Guang-Yan; Peng, Xin

    2015-10-01

    Orbital floor defects after extensive maxillectomy can cause severe esthetic and functional deformities. Orbital floor reconstruction using the computer-assisted fabricated individual titanium mesh technique is a promising method. This study evaluated the application and clinical outcomes of this technique. This retrospective study included 10 patients with orbital floor defects after maxillectomy performed from 2012 through 2014. A 3-dimensional individual stereo model based on mirror images of the unaffected orbit was obtained to fabricate an anatomically adapted titanium mesh using computer-assisted design and manufacturing. The titanium mesh was inserted into the defect using computer navigation. The postoperative globe projection and orbital volume were measured and the incidence of postoperative complications was evaluated. The average postoperative globe projection was 15.91 ± 1.80 mm on the affected side and 16.24 ± 2.24 mm on the unaffected side (P = .505), and the average postoperative orbital volume was 26.01 ± 1.28 and 25.57 ± 1.89 mL, respectively (P = .312). The mean mesh depth was 25.11 ± 2.13 mm. The mean follow-up period was 23.4 ± 7.7 months (12 to 34 months). Of the 10 patients, 9 did not develop diplopia or a decrease in visual acuity and ocular motility. Titanium mesh exposure was not observed in any patient. All patients were satisfied with their postoperative facial symmetry. Orbital floor reconstruction after extensive maxillectomy with an individual titanium mesh fabricated using computer-assisted techniques can preserve globe projection and orbital volume, resulting in successful clinical outcomes. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Can visual assessment of blood flow patterns by dynamic contrast-enhanced computed tomography distinguish between malignant and benign lung tumors?

    Science.gov (United States)

    Harders, Stefan Walbom; Madsen, Hans Henrik; Nellemann, Hanne Marie; Rasmussen, Torben Riis; Thygesen, Jesper; Hager, Henrik; Andersen, Niels Trolle; Rasmussen, Finn

    2017-05-01

    Dynamic contrast-enhanced computed tomography (DCE-CT) is a tool, which, in theory, can quantify the blood flow and blood volume of tissues. In structured qualitative analysis, parametric color maps yield a visual impression of the blood flow and blood volume within the tissue being studied, allowing for quick identification of the areas with the highest or lowest blood flow and blood volume. To examine whether DCE-CT could be used to distinguish between malignant and benign lung tumors in patients with suspected lung cancer. Fifty-nine patients with suspected lung cancer and a lung tumor on their chest radiograph were included for DCE-CT. The tumors were categorized using structured qualitative analysis of tumor blood flow patterns. Histopathology was used as reference standard. Using structured qualitative analysis of tumor blood flow patterns, it was possible to distinguish between malignant and benign lung tumors (Fisher-Freeman-Halton exact test, P  = 0.022). The inter-reader agreement of this method of analysis was slight to moderate (kappa = 0.30; 95% confidence interval [CI] = 0.13-0.46). DCE-CT in suspected lung cancer using structured qualitative analysis of tumor blood flow patterns is accurate as well as somewhat reproducible. However, there are significant limitations to DCE-CT.

  1. Computer game assisted instruction and students' achievement in ...

    African Journals Online (AJOL)

    Computer game assisted instruction and students' achievement in social studies. ... This paper examines the effects of computer game assisted instructional method, student's achievement in social studies in ... AJOL African Journals Online.

  2. Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer.

    Science.gov (United States)

    Karava, Konstantina; Ehrbar, Stefanie; Riesterer, Oliver; Roesch, Johannes; Glatz, Stefan; Klöck, Stephan; Guckenberger, Matthias; Tanadini-Lang, Stephanie

    2017-11-09

    Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach was performed. The two respiratory motion-management techniques were compared in terms of doses to the target volume and organs at risk. Two volumetric-modulated arc therapy (VMAT) treatment plans (5 × 5 Gy) were created for each of the 12 previously treated pancreatic cancer patients, one using the ITV concept and one the tumor tracking approach. To better evaluate the overall dose delivered to the moving tumor volume, 4D dose calculations were performed on four-dimensional computed tomography (4DCT) scans. The resulting planning target volume (PTV) size for each technique was analyzed. Target and OAR dose parameters were reported and analyzed for both 3D and 4D dose calculation. Tumor motion ranged from 1.3 to 11.2 mm. Tracking led to a reduction of PTV size (max. 39.2%) accompanied with significant better tumor coverage (p<0.05, paired Wilcoxon signed rank test) both in 3D and 4D dose calculations and improved organ at risk sparing. Especially for duodenum, stomach and liver, the mean dose was significantly reduced (p<0.05) with tracking for 3D and 4D dose calculations. By using an adaptive tumor tracking approach for respiratory-induced pancreatic motion management, a significant reduction in PTV size can be achieved, which subsequently facilitates treatment planning, and improves organ dose sparing. The dosimetric benefit of tumor tracking is organ and patient-specific.

  3. Minimally invasive endoscope-assisted trans-oral excision of huge parapharyngeal space tumors.

    Science.gov (United States)

    Li, Shang-Yi; Hsu, Ching-Hui; Chen, Mu-Kuan

    2015-04-01

    Parapharyngeal space tumors are rare head and neck neoplasms, and most are benign lesions. Complete excision of these tumors is difficult because of the complexity of the surrounding anatomic structures. The algorithm for excision of these tumors is typically based on the tumor's characteristics; excision is performed via approaches such as the trans-oral route, the trans-cervical route, and even a combination of the trans-parotid route and mandibulotomy. However, each of these approaches is associated with some complications. Endoscope-assisted minimally invasive surgery is being increasingly employed for surgeries in the head and neck regions. It has the advantage of leaving no facial scars, and ensures better patient comfort after the operation. Here, we report the use of endoscope-assisted trans-oral surgery for excision of parapharyngeal space tumors. The technique yields an excellent outcome and should be a feasible, safe, and economic method for these patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Faisal [University of Utah School of Medicine, Salt Lake City, UT (United States); Loma Linda University Medical Center, Department of Radiation Oncology, Loma Linda, CA (United States); Sarkar, Vikren; Gaffney, David K.; Salter, Bill [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States); Poppe, Matthew M., E-mail: matthew.poppe@hci.utah.edu [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States)

    2016-10-01

    Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In

  5. Impact of removed tumor volume and location on patient outcome in glioblastoma.

    Science.gov (United States)

    Awad, Al-Wala; Karsy, Michael; Sanai, Nader; Spetzler, Robert; Zhang, Yue; Xu, Yizhe; Mahan, Mark A

    2017-10-01

    Glioblastoma is an aggressive primary brain tumor with devastatingly poor prognosis. Multiple studies have shown the benefit of wider extent of resection (EOR) on patient overall survival (OS) and worsened survival with larger preoperative tumor volumes. However, the concomitant impact of postoperative tumor volume and eloquent location on OS has yet to be fully evaluated. We performed a retrospective chart review of adult patients treated for glioblastoma from January 2006 through December 2011. Adherence to standardized postoperative chemoradiation protocols was used as an inclusion criterion. Detailed volumetric and location analysis was performed on immediate preoperative and immediate postoperative magnetic resonance imaging. Cox proportional hazard modeling approach was employed to explore the modifying effects of EOR and eloquent location after adjusting for various confounders and associated characteristics, such as preoperative tumor volume and demographics. Of the 471 screened patients, 141 were excluded because they did not meet all inclusion criteria. The mean (±SD) age of the remaining 330 patients (60.6% male) was 58.9 ± 12.9 years; the mean preoperative and postoperative Karnofsky performance scores (KPSs) were 76.2 ± 10.3 and 80.0 ± 16.6, respectively. Preoperative tumor volume averaged 33.2 ± 29.0 ml, postoperative residual was 4.0 ± 8.1 ml, and average EOR was 88.6 ± 17.6%. The observed average follow-up was 17.6 ± 15.7 months, and mean OS was 16.7 ± 14.4 months. Survival analysis showed significantly shorter survival for patients with lesions in periventricular (16.8 ± 1.7 vs. 21.5 ± 1.4 mo, p = 0.03), deep nuclei/basal ganglia (11.6 ± 1.7 vs. 20.6 ± 1.2, p = 0.002), and multifocal (12.0 ± 1.4 vs. 21.3 ± 1.3 months, p = 0.0001) locations, but no significant influence on survival was seen for eloquent cortex sites (p = 0.14, range 0.07-0.9 for all individual

  6. Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy

    Science.gov (United States)

    Lee, Songhyun; Jeong, Hyeryun; Seong, Myeongsu; Kim, Jae Gwan

    2017-12-01

    Breast cancer is one of the most common cancers in females. To monitor chemotherapeutic efficacy for breast cancer, medical imaging systems such as x-ray mammography, computed tomography, magnetic resonance imaging, and ultrasound imaging have been used. Currently, it can take up to 3 to 6 weeks to see the tumor response from chemotherapy by monitoring tumor volume changes. We used near-infrared spectroscopy (NIRS) to predict breast cancer treatment efficacy earlier than tumor volume changes by monitoring tumor vascular reactivity during inhalational gas interventions. The results show that the amplitude of oxy-hemoglobin changes (vascular reactivity) during hyperoxic gas inhalation is well correlated with tumor growth and responded one day earlier than tumor volume changes after chemotherapy. These results may imply that NIRS with respiratory challenges can be useful in early detection of tumor and in the prediction of tumor response to chemotherapy.

  7. Intelligent computer-generated tumor volumetrics: New automated technique

    International Nuclear Information System (INIS)

    Macrea, K.; Fishman, E.K.

    1987-01-01

    Slice data from scanners are placed in a 3D array in one-to-one correspondence with their physical origins. The organ of interest is isolated using ''soft'' scan (CT, MR, etc.) number windows and geometric information. Voxels at the ''edges'' of ''soft'' windows contribute fractionally. The organ's position is used, as is its ''shape,'' especially if adjacent tissues have similar scan numbers; then smooth boundary curve fitting is also used. The total of (fractionally) contributing voxels is proportional to the organ volume. The total contributing voxels in the subregion with ''soft'' tumor tissue type yields the tumor volume

  8. Computer-Assisted Discovery and Proof

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.; Borwein, Jonathan M.

    2007-12-10

    With the advent of powerful, widely-available mathematical software, combined with ever-faster computer hardware, we are approaching a day when both the discovery and proof of mathematical facts can be done in a computer-assisted manner. his article presents several specific examples of this new paradigm in action.

  9. CT-assisted transcutaneous interstitial implantation of thoracic tumors: Early experience

    International Nuclear Information System (INIS)

    Heelan, R.T.; Hilaris, B.S.; Anderson, L.; Caravelli, J.F.; Nori, D.; Martini, N.; Watson, R.C.; Linares, L.

    1986-01-01

    The authors have transcutaneously implanted I-125 radioactive seeds in six patients with thoracic tumors (three with lung cancer; three with metastases) to determine the feasibility of this procedure. In four patients the thoracic tumors were localized without evidence of distant metastases, but these patients were not candidates for resection because of chronic pulmonary disease. Tumor volume was measured on CT scans (with sagittal and coronal reconstructions) and the required number of seeds was determined based on tumor volume. Between 6 and 11 needles were placed in the tumor and the seeds were implanted as the needle was withdrawn. Between 40 and 60 seeds were implanted in each patient, under local anesthesia. In this preliminary series all patients were found to have tumor attached to pleura. Four of the six patients underwent implantation during a day-time admission to the institution's Adult Day Hospital. No patient suffered any complication as a result of the procedure. Four patients experienced a symptomatic relief of pain and a decrease in size of tumor bulk (local control). Two patients eventually exhibited renewed tumor growth in the edges of the implanted mass after 6 months; the authors plan to supplement future implantations with external radiation therapy. One patient underwent implantation after local recurrence of tumor, returned to work the day following the procedure, and is without evidence of local recurrence 18 months later. They are encouraged by these preliminary results, for several reasons: the lack of morbidity, the achievement of local control of tumor while avoiding surgery and its potential complications, and avoidance of hospital stay (with consequent financial savings). The intent is to expand this series to include patients with lung tumors not attached to pleura

  10. Target Coverage in Image-Guided Stereotactic Body Radiotherapy of Liver Tumors

    International Nuclear Information System (INIS)

    Wunderink, Wouter; Romero, Alejandra Mendez; Osorio, Eliana M. Vasquez; Boer, Hans C.J. de; Brandwijk, Rene P.; Levendag, Peter C.; Heijmen, Ben

    2007-01-01

    Purpose: To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. Methods and Materials: By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV + ) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV + , derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Results: Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (≥99%) ITV + coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (≤2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Conclusion: Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging

  11. Study on delineation of tumor volume of primary locally advanced nasopharyngeal carcinoma after induction chemotherapy

    International Nuclear Information System (INIS)

    Long Jinhua; Dong Shi; Jin Feng; Wu Weili; Gan Jiaying; Chen Haixia; Li Yuanyuan; Gong Xiuyun

    2012-01-01

    Objective: To investigate the delineation of gross tumor volume (GTV) in locally advanced nasopharyngeal carcinoma (LANC) according to imageological changes before and after induction chemotherapy (IC) in order to decrease high dose area and protect normal tissue better. Methods: Between Mar 2010 to Jan 2011, 11 patients with LANC were enrolled and treated with TPF regimen followed by intensity-modulated radiotherapy (IMRT) with concurrent chemotherapy, target volumes were delineated based on fused CT imaging before and after IC following project determination. Tumor target volumes after and before IC were respectively delineated according to imaging tumor residues and were overlaid by CTV nx in order to ensure radical doses for the imaging tumor volume before IC, the resulting differences of tumor target volumes of IC before and after were measured and analyzed by paired t-test. Results: Before and after IC, the average volumes of GTV nx were respectively 44.72 cm 3 and 28.87 (t=3.89, P=0.003), the average volumes of GTV nd were respectively 32.76 cm 3 and 19.82 cm 3 (t=2.47, P=0.033), the volumes of maximum dose area in brainstem and spinal cord as well as eyeball decreased (t=2.93-4.59, all P<0.05). Conclusions: LANC treated by 3 cycle TPF regimen followed by IMRT with concurrent chemotherapy shows significant shrinkage of tumor volume. The volume of high dose region which caused by normally recovered tissues were decreased by re-delineation of target volume in brainstem and spinal cord as well as eyeball of CT images after IC. (authors)

  12. Computer-assisted design/computer-assisted manufacturing systems: A revolution in restorative dentistry

    Directory of Open Access Journals (Sweden)

    Arbaz Sajjad

    2016-01-01

    Full Text Available For the better part of the past 20 years, dentistry has seen the development of many new all-ceramic materials and restorative techniques fueled by the desire to capture the ever elusive esthetic perfection. This has resulted in the fusion of the latest in material science and the pen ultimate in computer-assisted design/computer-assisted manufacturing (CAD/CAM technology. This case report describes the procedure for restoring the esthetic appearance of both the left and right maxillary peg-shaped lateral incisors with a metal-free sintered finely structured feldspar ceramic material using the latest laboratory CAD/CAM system. The use of CAD/CAM technology makes it possible to produce restorations faster with precision- fit and good esthetics overcoming the errors associated with traditional ceramo-metal technology. The incorporation of this treatment modality would mean that the dentist working procedures will have to be adapted in the methods of CAD/CAM technology.

  13. Co-clinical quantitative tumor volume imaging in ALK-rearranged NSCLC treated with crizotinib

    Energy Technology Data Exchange (ETDEWEB)

    Nishino, Mizuki, E-mail: Mizuki_Nishino@DFCI.HARVARD.EDU [Department of Radiology, Brigham and Women’s Hospital, 450 Brookline Ave., Boston MA, 02215 (United States); Department of Imaging, Dana-Farber Cancer Institute, 450 Brookline Ave., Boston MA, 02215 (United States); Sacher, Adrian G.; Gandhi, Leena; Chen, Zhao; Akbay, Esra [Department of Medical Oncology and Department of Medicine Dana-Farber Cancer Institute and Brigham and Women’s Hospital 450 Brookline Ave., Boston MA, 02215 (United States); Fedorov, Andriy; Westin, Carl F.; Hatabu, Hiroto [Department of Radiology, Brigham and Women’s Hospital, 450 Brookline Ave., Boston MA, 02215 (United States); Johnson, Bruce E.; Hammerman, Peter; Wong, Kwok-kin [Department of Medical Oncology and Department of Medicine Dana-Farber Cancer Institute and Brigham and Women’s Hospital 450 Brookline Ave., Boston MA, 02215 (United States)

    2017-03-15

    Highlights: • Role of co-clinical studies in precision cancer medicine is increasingly recognized. • This study compared tumor volume in co-clinical trials of ALK-rearranged NSCLC. • Similarities and differences of tumor volume changes in mice and humans were noted. • The study provides insights to optimize murine co-clinical trial designs. - Abstract: Purpose: To evaluate and compare the volumetric tumor burden changes during crizotinib therapy in mice and human cohorts with ALK-rearranged non-small-cell lung cancer (NSCLC). Methods: Volumetric tumor burden was quantified on serial imaging studies in 8 bitransgenic mice with ALK-rearranged adenocarcinoma treated with crizotinib, and in 33 human subjects with ALK-rearranged NSCLC treated with crizotinib. The volumetric tumor burden changes and the time to maximal response were compared between mice and humans. Results: The median tumor volume decrease (%) at the maximal response was −40.4% (range: −79.5%–+11.7%) in mice, and −72.9% (range: −100%–+72%) in humans (Wilcoxon p = 0.03). The median time from the initiation of therapy to maximal response was 6 weeks in mice, and 15.7 weeks in humans. Overall volumetric response rate was 50% in mice and 97% in humans. Spider plots of tumor volume changes during therapy demonstrated durable responses in the human cohort, with a median time on therapy of 13.1 months. Conclusion: The present study described an initial attempt to evaluate quantitative tumor burden changes in co-clinical imaging studies of genomically-matched mice and human cohorts with ALK-rearranged NSCLC treated with crizotinib. Differences are noted in the degree of maximal volume response between the two cohorts in this well-established paradigm of targeted therapy, indicating a need for further studies to optimize co-clinical trial design and interpretation.

  14. Co-clinical quantitative tumor volume imaging in ALK-rearranged NSCLC treated with crizotinib

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Sacher, Adrian G.; Gandhi, Leena; Chen, Zhao; Akbay, Esra; Fedorov, Andriy; Westin, Carl F.; Hatabu, Hiroto; Johnson, Bruce E.; Hammerman, Peter; Wong, Kwok-kin

    2017-01-01

    Highlights: • Role of co-clinical studies in precision cancer medicine is increasingly recognized. • This study compared tumor volume in co-clinical trials of ALK-rearranged NSCLC. • Similarities and differences of tumor volume changes in mice and humans were noted. • The study provides insights to optimize murine co-clinical trial designs. - Abstract: Purpose: To evaluate and compare the volumetric tumor burden changes during crizotinib therapy in mice and human cohorts with ALK-rearranged non-small-cell lung cancer (NSCLC). Methods: Volumetric tumor burden was quantified on serial imaging studies in 8 bitransgenic mice with ALK-rearranged adenocarcinoma treated with crizotinib, and in 33 human subjects with ALK-rearranged NSCLC treated with crizotinib. The volumetric tumor burden changes and the time to maximal response were compared between mice and humans. Results: The median tumor volume decrease (%) at the maximal response was −40.4% (range: −79.5%–+11.7%) in mice, and −72.9% (range: −100%–+72%) in humans (Wilcoxon p = 0.03). The median time from the initiation of therapy to maximal response was 6 weeks in mice, and 15.7 weeks in humans. Overall volumetric response rate was 50% in mice and 97% in humans. Spider plots of tumor volume changes during therapy demonstrated durable responses in the human cohort, with a median time on therapy of 13.1 months. Conclusion: The present study described an initial attempt to evaluate quantitative tumor burden changes in co-clinical imaging studies of genomically-matched mice and human cohorts with ALK-rearranged NSCLC treated with crizotinib. Differences are noted in the degree of maximal volume response between the two cohorts in this well-established paradigm of targeted therapy, indicating a need for further studies to optimize co-clinical trial design and interpretation.

  15. Effects of Thoracic Paravertebral Block on Postoperative Analgesia and Serum Level of Tumor Marker in Lung Cancer Patients Undergoing Video-assisted Thoracoscopic Surgery

    Directory of Open Access Journals (Sweden)

    Jiheng CHEN

    2015-02-01

    Full Text Available Background and objective Perioperative management of pain associated with the prognosis of cancer patients. Optimization of perio-perative analgesia method, then reduce perioperative stress response, reduce opioiddosage, to reduce or even avoid systemic adverse reactions and elevated levels of tumor markers. Serum levels of tumor markers in patients with lung cancer are closely related to tumor growth. Clinical research reports on regional anesthesia effect on tumor markers for lung cancer are still very little in domesticliterature. The aim of this study is to evaluate the effects of thoracic paraverte-bral block on postoperative analgesia and serum level of tumor marker in lung cancer patients undergoing video-assisted thoracoscopic surgery. Methods Lung cancer patients undergoing video-assisted thoracoscopic surgery were randomly divided into 2 groups (n=20 in each group. The patients in group G were given only general anesthesia. The thoracic paravertebral blockade (PVB was performed before general anesthesia in patients of group GP. The effect of PVB was judged by testing area of block. Patient controlled intravenous analgesia (PCIA pump started before the end of surgery in 2 groups. Visual analogue scale (VAS score was recorded after extubation 2 h (T1, 24 h (T2 and 48 h (T3 after surgery and the times of PCIA and the volume of analgesic drugs used were recorded during 48 h after surgery. The serum levels of carcino-embryonic antigen (CEA, carbohydrate antigen 199 (CA199, carbohydrate antigen 125 (CA125, neuron-specific enolase (NSE, cytokeratin 19 fragment (CYFRA21-1 and squamous cell carcinoma (SCC in 40 lung cancer cases undergoing video-assisted thoracoscopic lobectomy were measured before operation and 24 h after operation. Results Forty American Society of Anesthesiologists (ASA physical status I or II patients, aged 20 yr-70 yr, body mass index (BMI 18 kg/m2-25 kg/m2, scheduled for elective video-assisted thoraeoscopic lobectomy

  16. Change of tumor target volume during waiting time for intensity-modulated radiotherapy (IMRT) in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Chen Bo; Yi Junlin; Gao Li; Xu Guozhen; Huang Xiaodong; Zhang Zhong; Luo Jingwei; Li Suyan

    2007-01-01

    Objective: To determine the influence of change in tumor target volume of nasopharyngeal carcinoma (NPC) while waiting for intensity modulated radiation therapy (IMRT). Methods: From March 2005 to December 2005, 31 patients with nasopharyngeal carcinoma received IMRT as the initial treatment at the Cancer Hospital of Chinese Academic of Medical Sciences. The original simulation CT scan was acquired before IMRT planning. A second CT scan was acquired before the start of radiotherapy. Wait- ing time was defined as the duration between CT simulation and start of radiotherapy. CT-CT fusion was used to minimize the error of delineation between the first tumor target volume (GTV) and the second tumor target volume (sGTV). Tumor target volume was calculated by treatment planning system. T test was carried out to analyse the difference between GTV and sGTV. Pearson correlation and multivariate linear regression was used to analyse the influence factor of the change betweent GTV and sGTV. Results: Median waiting time was 18 days (range, 9-27 days). There were significant differences between GTV and sGTV of both primary tumor (P=0.009) and metastatic lymphoma (P=0.005 ). Both Pearson correlation and multivariate linear regression showed that the change of primary tumor target volume had significant correlation with the first tumor target volume but had no significant correlation with the waiting time, sex, age, T stage and N stage (1992 Chinese Fuzhou Staging Classification). Conclusions: Within the range of the waiting time ob- served in our study, large volume primary tumor would have had a significant increase in volume, but whether the therapeutic effect would be influenced or not would need to be proved by study of large number of cases. Patients with large volume tumor should be considered to reduce the influence of waiting time by enlarging gross target volume and clinical targe volume and by neoadjuveant chemotherapy. For avoiding the unnecessary high-dose to normal

  17. Correlation of Tumor and Peritumoral Edema Volumes with Survival in Patients with Cerebral Metastases.

    Science.gov (United States)

    Kerschbaumer, Johannes; Bauer, Marlies; Popovscaia, Marina; Grams, Astrid E; Thomé, Claudius; Freyschlag, Christian F

    2017-02-01

    Surgical resection in combination with radiotherapy in selected cases remains the best option for patients with cerebral metastases. Postoperative relapse of brain metastases occurs frequently and can be reduced by postoperative whole-brain radiotherapy (WBRT). Continuous spread of tumor cells from the primary lesions is debated as a cause of recurrence. It is well known that in gliomas, infiltration takes place within the surrounding edema. Obviously, most brain metastases are usually associated with peritumoral edema, which may act as an indicator of infiltration and more aggressive tumor biology. Therefore, we aimed to investigate the correlation of tumor and edema volumes with overall survival in patients with cerebral metastases. A total of 143 patients diagnosed with brain metastasis (male:female=1.1:1) who underwent surgical resection were included retrospectively in this analysis. Clinical data were retrieved from electronic patient files. The volumes of tumor and edema calculated by manual delineation. The ratio of edema to tumor volume was calculated, leading to dichotomization of the patients. The median tumor volume was 20.1 cc (range=0.8-90.8 cc) and the median volume of edema 49.5 cc (range=0-179.9 cc). The volume of metastases did not significantly correlate with overall survival. The ratio of edema to tumor volume was also not a prognostic factor in terms of overall survival. Only surgical resection, preoperative recursive partitioning analysis class, and postoperative addition of WBRT, as well as female sex, demonstrated beneficial effects. The extent of edema surrounding cerebral metastases does not appear to influence overall survival in patients suffering from brain metastases, although it seems to be responsible for most of the patients' symptoms. The hypothesis that the extent of edema was disadvantageous concerning survival was supported by our data. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios

  18. Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering; Die computerassistierte Operationsplanung in der Abdominalchirurgie des Kindes. 3D-Visualisierung mittels ''volume rendering'' in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, P.; Holland-Cunz, S.; Waag, K.L. [Universitaetsklinikum Heidelberg (Germany). Kinderchirurgie; Troeger, J. [Universitaetsklinikum Heidelberg, (Germany). Paediatrische Radiologie; Schenk, J.P. [Universitaetsklinikum Heidelberg, (Germany). Paediatrische Radiologie; Universitaetsklinikum, Paediatrische Radiologie, Heidelberg (Germany)

    2006-08-15

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this. A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning. (orig.) [German] Komplexe Operationen bei ausgepraegten pathologischen Veraenderungen anatomischer Strukturen des kindlichen Abdomens benoetigen eine exakte Operationsvorbereitung. 3D-Visualisierung und computerassistierte Operationsplanung anhand von CT-Daten finden fuer schwierige chirurgische Eingriffe bei Erwachsenen in zunehmendem Masse Anwendung. Aus strahlenhygienischen Gruenden und bei besserer Weichteildifferenzierung ist jedoch neben der Sonographie die Magnetresonanztomographie (MRT) bei Kindern das Diagnostikum der Wahl. Die 3D-Visualisierung dieser MRT-Daten ist dabei jedoch aufgrund vielfaeltiger Schwierigkeiten bisher nicht durchgefuehrt worden, obwohl sich das Gebiet embryonaler Fehlbildungen und Tumoren geradezu anbietet. Vorgestellt wird eine weiterentwickelte und an die Fragestellungen der abdominellen Kinderchirurgie angepasste, sehr leistungsstarke raycastingbasierte 3D-volume-rendering-Software (VG Studio Max 1

  19. Evaluation of PET/MRI for Tumor Volume Delineation for Head and Neck Cancer.

    Science.gov (United States)

    Wang, Kyle; Mullins, Brandon T; Falchook, Aaron D; Lian, Jun; He, Kelei; Shen, Dinggang; Dance, Michael; Lin, Weili; Sills, Tiffany M; Das, Shiva K; Huang, Benjamin Y; Chera, Bhishamjit S

    2017-01-01

    Computed tomography (CT), combined positron emitted tomography and CT (PET/CT), and magnetic resonance imaging (MRI) are commonly used in head and neck radiation planning. Hybrid PET/MRI has garnered attention for potential added value in cancer staging and treatment planning. Herein, we compare PET/MRI vs. planning CT for head and neck cancer gross tumor volume (GTV) delineation. We prospectively enrolled patients with head and neck cancer treated with definitive chemoradiation to 60-70 Gy using IMRT. We performed pretreatment contrast-enhanced planning CT and gadolinium-enhanced PET/MRI. Primary and nodal volumes were delineated on planning CT (GTV-CT) prospectively before treatment and PET/MRI (GTV-PET/MRI) retrospectively after treatment. GTV-PET/MRI was compared to GTV-CT using separate rigid registrations for each tumor volume. The Dice similarity coefficient (DSC) metric evaluating spatial overlap and modified Hausdorff distance (mHD) evaluating mean orthogonal distance difference were calculated. Minimum dose to 95% of GTVs (D95) was compared. Eleven patients were evaluable (10 oropharynx, 1 larynx). Nine patients had evaluable primary tumor GTVs and seven patients had evaluable nodal GTVs. Mean primary GTV-CT and GTV-PET/MRI size were 13.2 and 14.3 cc, with mean intersection 8.7 cc, DSC 0.63, and mHD 1.6 mm. D95 was 65.3 Gy for primary GTV-CT vs. 65.2 Gy for primary GTV-PET/MRI. Mean nodal GTV-CT and GTV-PET/MRI size were 19.0 and 23.0 cc, with mean intersection 14.4 cc, DSC 0.69, and mHD 2.3 mm. D95 was 62.3 Gy for both nodal GTV-CT and GTV-PET/MRI. In this series of patients with head and neck (primarily oropharynx) cancer, PET/MRI and CT-GTVs had similar volumes (though there were individual cases with larger differences) with overall small discrepancies in spatial overlap, small mean orthogonal distance differences, and similar radiation doses.

  20. SU-E-T-427: Cell Surviving Fractions Derived From Tumor-Volume Variation During Radiotherapy for Non-Small Cell Lung Cancer: Comparison with Predictive Assays

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, A; Schwartz, J; Mayr, N [University of Washington, Seattle, WA (United States); Yartsev, S [London Health Sciences Centre, London, Ontario (Canada)

    2014-06-01

    Purpose: To show that a distribution of cell surviving fractions S{sub 2} in a heterogeneous group of patients can be derived from tumor-volume variation curves during radiotherapy for non-small cell lung cancer. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage (MV) computed tomography (CT). Statistical distributions of cell surviving fractions S{sup 2} and cell clearance half-lives of lethally damaged cells T1/2 have been reconstructed in each patient group by using a version of the two-level cell population tumor response model and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Non-small cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractions S{sub 2} for non-small cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sup 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Comparison of the reconstructed cell surviving fractions with patient survival data shows that the patient survival time decreases as the cell surviving fraction increases. Conclusion: The data obtained in this work suggests that the cell surviving fractions S{sub 2} can be reconstructed from the tumor volume

  1. SU-E-T-427: Cell Surviving Fractions Derived From Tumor-Volume Variation During Radiotherapy for Non-Small Cell Lung Cancer: Comparison with Predictive Assays

    International Nuclear Information System (INIS)

    Chvetsov, A; Schwartz, J; Mayr, N; Yartsev, S

    2014-01-01

    Purpose: To show that a distribution of cell surviving fractions S 2 in a heterogeneous group of patients can be derived from tumor-volume variation curves during radiotherapy for non-small cell lung cancer. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage (MV) computed tomography (CT). Statistical distributions of cell surviving fractions S 2 and cell clearance half-lives of lethally damaged cells T1/2 have been reconstructed in each patient group by using a version of the two-level cell population tumor response model and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Non-small cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractions S 2 for non-small cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S 2 reconstructed from tumor volume variation agree with the PDF measured in vitro. Comparison of the reconstructed cell surviving fractions with patient survival data shows that the patient survival time decreases as the cell surviving fraction increases. Conclusion: The data obtained in this work suggests that the cell surviving fractions S 2 can be reconstructed from the tumor volume variation curves measured

  2. Computed tomography scans of metastatic hepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Fukuda, Haruyuki; Nemoto, Yutaka [Osaka City Univ. (Japan). Faculty of Medicine

    1984-01-01

    Computed tomography scans of 114 metastatic hepatic tumors were reviewed. Central low density was found in 82 cases (71.9%) and seems to be characteristic to metastatic hepatic tumors. Dynamic CT was performed on 34 cases, and 21 (61.8%) of these had ring enhancement at the arterial phase. Most of metastatic hepatic tumors could be differentiated from hepatocellular carcinoma. However, metastatic hepatic tumors from renal cell carcinoma, renal rhabdomyosarcoma, malignant melanoma and leiomyosarcoma could not be differentiated from hepatocellular carcinoma, even with use of dynamic study.

  3. Computer-aided diagnosis of liver tumors on computed tomography images.

    Science.gov (United States)

    Chang, Chin-Chen; Chen, Hong-Hao; Chang, Yeun-Chung; Yang, Ming-Yang; Lo, Chung-Ming; Ko, Wei-Chun; Lee, Yee-Fan; Liu, Kao-Lang; Chang, Ruey-Feng

    2017-07-01

    Liver cancer is the tenth most common cancer in the USA, and its incidence has been increasing for several decades. Early detection, diagnosis, and treatment of the disease are very important. Computed tomography (CT) is one of the most common and robust imaging techniques for the detection of liver cancer. CT scanners can provide multiple-phase sequential scans of the whole liver. In this study, we proposed a computer-aided diagnosis (CAD) system to diagnose liver cancer using the features of tumors obtained from multiphase CT images. A total of 71 histologically-proven liver tumors including 49 benign and 22 malignant lesions were evaluated with the proposed CAD system to evaluate its performance. Tumors were identified by the user and then segmented using a region growing algorithm. After tumor segmentation, three kinds of features were obtained for each tumor, including texture, shape, and kinetic curve. The texture was quantified using 3 dimensional (3-D) texture data of the tumor based on the grey level co-occurrence matrix (GLCM). Compactness, margin, and an elliptic model were used to describe the 3-D shape of the tumor. The kinetic curve was established from each phase of tumor and represented as variations in density between each phase. Backward elimination was used to select the best combination of features, and binary logistic regression analysis was used to classify the tumors with leave-one-out cross validation. The accuracy and sensitivity for the texture were 71.82% and 68.18%, respectively, which were better than for the shape and kinetic curve under closed specificity. Combining all of the features achieved the highest accuracy (58/71, 81.69%), sensitivity (18/22, 81.82%), and specificity (40/49, 81.63%). The Az value of combining all features was 0.8713. Combining texture, shape, and kinetic curve features may be able to differentiate benign from malignant tumors in the liver using our proposed CAD system. Copyright © 2017 Elsevier B.V. All

  4. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  5. Computer-assisted nuclear fuel manufacture

    International Nuclear Information System (INIS)

    Maloney, J.P.; Schaumann, S.M.; Stone, E.

    1976-01-01

    At the ERDA Savannah River Plant, a process monitor, which incorporates an online digital computer, assists in manufacturing fuel elements used to produce nuclides such as plutonium, tritium, and californium in the plant's nuclear reactors. Also, inventory functions assist in safeguarding fissile material and protecting against accidental nuclear criticality. Terminals at strategic locations throughout the process area enable production operators to send and receive instructions and information on each manufacturing step

  6. Optimal gross tumor volume definition in lung-sparing intensity modulated radiotherapy for pleural mesothelioma: an in silico study.

    Science.gov (United States)

    Botticella, Angela; Defraene, Gilles; Nackaerts, Kristiaan; Deroose, Christophe M; Coolen, Johan; Nafteux, Philippe; Peeters, Stephanie; Ricardi, Umberto; De Ruysscher, Dirk

    2016-12-01

    The gross tumor volume (GTV) definition for malignant pleural mesothelioma (MPM) is ill-defined. We therefore investigated which imaging modality is optimal: computed tomography (CT) with intravenous contrast (IVC), positron emission tomography-CT (PET/CT) or magnetic resonance imaging (MRI). Sixteen consecutive patients with untreated stage I-IV MPM were included. Patients with prior pleurodesis were excluded. CT with IVC, 18FDG-PET/CT and MRI (T2 and contrast-enhanced T1) were obtained. CT was rigidly co-registered with PET/CT and with MRI. Three sets of pleural GTVs were defined: GTV CT , GTV CT+PET/CT and GTV CT+MRI . Quantitative and qualitative evaluations of the contoured GTVs were performed. Compared to CT-based GTV definition, PET/CT identified additional tumor sites (defined as either separate nodules or greater extent of a known tumor) in 12/16 patients. Compared to either CT or PET/CT, MRI identified additional tumor sites in 15/16 patients (p = .7). The mean GTV CT , GTV CT+PET/CT and GTV CT+MRI [±standard deviation (SD)] were 630.1 cm 3 (±302.81), 640.23 cm 3 (±302.83) and 660.8 cm 3 (±290.8), respectively. Differences in mean volumes were not significant. The mean Jaccard Index was significantly lower in MRI-based contours versus all the others. As MRI identified additional pleural disease sites in the majority of patients, it may play a role in optimal target volume definition.

  7. Quantitative study on lung volume and lung perfusion using SPECT and CT in thoracal tumors

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Strauss, L.G.

    1988-01-01

    22 patients with space occupying lesions in the thoracal region were investigated by computer tomography and by perfusion scintigraphy using SPECT. In order to evaluate the CT images quantitatively, the lung volume was determined using approximation method and compared with the perfusion in the SPECT study. For this, anatomically equivalent transaxial SPECT slices had been coordinated to the CT slices. Between the determined lung volumes and the activity in the ocrresponding layers, a statistically significant correlation was found. It could be shown that the stronger perfusion, frequently observed at the right side of the healthy lung, may be explained by an higher volume of the right pulmonary lobe. Whereas in benign displacing processes the relation activity to volume was similar to the one of the healthy lung, a strongly reduced perfusion together with inconspicuous lung volumes became apparent with malignant tumors. In addition to the great morphological evidence of CT and SPECT studies, additional informations regarding the dignity of displacing processes may be derived from the quantitative evaluation of both methods. (orig.) [de

  8. Laparoscopic hand-assisted adrenalectomy for a 20 cm benign tumor.

    Science.gov (United States)

    Popescu, I; Tomulescu, V; Hrehoret, D; Popescu, A; Herlea, V

    2007-01-01

    Since its introduction in 1992, laparoscopic adrenalectomy (LA) has become the technique of choice in the surgical treatment of both secreting or non-secreting benign adrenal pathology. Although traditionally, laparoscopic approach was recommended only for tumor sizes less than 6-8 cm--as larger tumors were known to have an increased risk of malignancy--the currently growing experience and improvement of surgical techniques has allowed for an extension of the therapeutic indication, as shown by the recent case report of LA use for a benign 22 cm tumor (1). We report the case of a young patient operated in our Department for a benign 20 cm adrenal tumor for which laparoscopic "hand-assisted" adrenalectomy yielded a good postoperative outcome and minimal complications.

  9. Improvement of internal tumor volumes of non-small cell lung cancer patients for radiation treatment planning using interpolated average CT in PET/CT.

    Directory of Open Access Journals (Sweden)

    Yao-Ching Wang

    Full Text Available Respiratory motion causes uncertainties in tumor edges on either computed tomography (CT or positron emission tomography (PET images and causes misalignment when registering PET and CT images. This phenomenon may cause radiation oncologists to delineate tumor volume inaccurately in radiotherapy treatment planning. The purpose of this study was to analyze radiology applications using interpolated average CT (IACT as attenuation correction (AC to diminish the occurrence of this scenario. Thirteen non-small cell lung cancer patients were recruited for the present comparison study. Each patient had full-inspiration, full-expiration CT images and free breathing PET images by an integrated PET/CT scan. IACT for AC in PET(IACT was used to reduce the PET/CT misalignment. The standardized uptake value (SUV correction with a low radiation dose was applied, and its tumor volume delineation was compared to those from HCT/PET(HCT. The misalignment between the PET(IACT and IACT was reduced when compared to the difference between PET(HCT and HCT. The range of tumor motion was from 4 to 17 mm in the patient cohort. For HCT and PET(HCT, correction was from 72% to 91%, while for IACT and PET(IACT, correction was from 73% to 93% (*p<0.0001. The maximum and minimum differences in SUVmax were 0.18% and 27.27% for PET(HCT and PET(IACT, respectively. The largest percentage differences in the tumor volumes between HCT/PET and IACT/PET were observed in tumors located in the lowest lobe of the lung. Internal tumor volume defined by functional information using IACT/PET(IACT fusion images for lung cancer would reduce the inaccuracy of tumor delineation in radiation therapy planning.

  10. Computer-assisted nuclear fuel manufacture

    International Nuclear Information System (INIS)

    Maloney, J.P.; Schaumann, C.M.; Stone, E.

    1976-06-01

    At the ERDA Savannah River Plant, a process monitor, which incorporates an online digital computer, assists in manufacturing fuel elements used to produce nuclides such as plutonium, tritium, and californium in the plant's nuclear reactors. Also, inventory functions assist in safeguarding fissile material and protecting against accidental nuclear criticality. Terminals at strategic locations throughout the process area enable production operators to send and receive instructions and information on each manufacturing step. 11 fig

  11. Evaluation of transurethral ultrasonography and computed tomography in the staging of bladder tumors

    International Nuclear Information System (INIS)

    Yamakawa, Kensuke; Hoshina, Akira; Tochigi, Hiromi; Kawamura, Juichi

    1987-01-01

    A definitive pathologic diagnosis was made in 47 patients with bladder tumors from cystectomy specimens or by surgical exploration. The tumor was staged in 35 cases by transurethral ultrasonography and in 39 cases by computed tomography. We obtained the following results : the accuracy was 83 % using transurethral sonography, 77 % using computed tomography. Although transurethral ultrasonography is more advantageous than computed tomography in the low stage in regard to accuracy, computed tomography is excellent method to obtain information about the tumor invasion and/or metastases. Of 25 cases combind with computed tomography and transurethral sonography. tumors were correctly staged by both methods in 18 cases (72 %). Histopathological stage was consistent with neither ultrasonographic stage nor computed tomographic stage in 2 cases, and any of these tumors was correctly staged by either of these methods. Although transurethral ultrasonography and computed tomography improve the clinical stage of the bladder tumors separately, some limitations and problems was recognized on using together with these methods for staging the bladder tumors. (author)

  12. Radiofrequency ablation of liver metastases-software-assisted evaluation of the ablation zone in MDCT: tumor-free follow-up versus local recurrent disease.

    Science.gov (United States)

    Keil, Sebastian; Bruners, Philipp; Schiffl, Katharina; Sedlmair, Martin; Mühlenbruch, Georg; Günther, Rolf W; Das, Marco; Mahnken, Andreas H

    2010-04-01

    The purpose of this study was to investigate differences in change of size and CT value between local recurrences and tumor-free areas after CT-guided radiofrequency ablation (RFA) of hepatic metastases during follow-up by means of dedicated software for automatic evaluation of hepatic lesions. Thirty-two patients with 54 liver metastases from breast or colorectal cancer underwent triphasic contrast-enhanced multidetector-row computed tomography (MDCT) to evaluate hepatic metastatic spread and localization before CT-guided RFA and for follow-up after intervention. Sixteen of these patients (65.1 + or - 10.3 years) with 30 metastases stayed tumor-free (group 1), while the other group (n = 16 with 24 metastases; 62.0 + or - 13.8 years) suffered from local recurrent disease (group 2). Applying an automated software tool (SyngoCT Oncology; Siemens Healthcare, Forchheim, Germany), size parameters (volume, RECIST, WHO) and attenuation were measured within the lesions before, 1 day after, and 28 days after RFA treatment. The natural logarithm (ln) of the quotient of the volume 1 day versus 28 days after RFA treament was computed: lnQ1//28/0(volume). Analogously, ln ratios of RECIST, WHO, and attenuation were computed and statistically evaluated by repeated-measures ANOVA. One lesion in group 2 was excluded from further evaluation due to automated missegmentation. Statistically significant differences between the two groups were observed with respect to initial volume, RECIST, and WHO (p free and local-recurrent ablation zones with respect to the corresponding size parameters. A new parameter (lnQ1//28/0(volume/RECIST/WHO/attenuation)) was introduced, which appears to be of prognostic value at early follow-up CT.

  13. Competency Reference for Computer Assisted Drafting.

    Science.gov (United States)

    Oregon State Dept. of Education, Salem. Div. of Vocational Technical Education.

    This guide, developed in Oregon, lists competencies essential for students in computer-assisted drafting (CAD). Competencies are organized in eight categories: computer hardware, file usage and manipulation, basic drafting techniques, mechanical drafting, specialty disciplines, three dimensional drawing/design, plotting/printing, and advanced CAD.…

  14. Functional computed tomography imaging of tumor-induced angiogenesis. Preliminary results of new tracer kinetic modeling using a computer discretization approach

    International Nuclear Information System (INIS)

    Kaneoya, Katsuhiko; Ueda, Takuya; Suito, Hiroshi

    2008-01-01

    The aim of this study was to establish functional computed tomography (CT) imaging as a method for assessing tumor-induced angiogenesis. Functional CT imaging was mathematically analyzed for 14 renal cell carcinomas by means of two-compartment modeling using a computer-discretization approach. The model incorporated diffusible kinetics of contrast medium including leakage from the capillary to the extravascular compartment and back-flux to the capillary compartment. The correlations between functional CT parameters [relative blood volume (rbv), permeability 1 (Pm1), and permeability 2 (Pm2)] and histopathological markers of angiogenesis [microvessel density (MVD) and vascular endothelial growth factor (VEGF)] were statistically analyzed. The modeling was successfully performed, showing similarity between the mathematically simulated curve and the measured time-density curve. There were significant linear correlations between MVD grade and Pm1 (r=0.841, P=0.001) and between VEGF grade and Pm2 (r=0.804, P=0.005) by Pearson's correlation coefficient. This method may be a useful tool for the assessment of tumor-induced angiogenesis. (author)

  15. Obtention of tumor volumes in PET images stacks using techniques of colored image segmentation

    International Nuclear Information System (INIS)

    Vieira, Jose W.; Lopes Filho, Ferdinand J.; Vieira, Igor F.

    2014-01-01

    This work demonstrated step by step how to segment color images of the chest of an adult in order to separate the tumor volume without significantly changing the values of the components R (Red), G (Green) and B (blue) of the colors of the pixels. For having information which allow to build color map you need to segment and classify the colors present at appropriate intervals in images. The used segmentation technique is to select a small rectangle with color samples in a given region and then erase with a specific color called 'rubber' the other regions of image. The tumor region was segmented into one of the images available and the procedure is displayed in tutorial format. All necessary computational tools have been implemented in DIP (Digital Image Processing), software developed by the authors. The results obtained, in addition to permitting the construction the colorful map of the distribution of the concentration of activity in PET images will also be useful in future work to enter tumors in voxel phantoms in order to perform dosimetric assessments

  16. Effect of tumor volume on the enhancement pattern of parathyroid adenoma on parathyroid four-dimensional CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Kyoung [Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Dongguk University Ilsan Hospital, Department of Radiology, Goyang-si (Korea, Republic of); Yun, Tae Jin; Kim, Ji-hoon; Kang, Koung Mi; Choi, Seung Hong; Sohn, Chul-Ho [Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Lee, Kyu Eun; Kim, Su-jin [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of); Won, Jae-Kyung [Seoul National University Hospital, Department of Pathology, Seoul (Korea, Republic of)

    2016-05-15

    The purpose of this study is to assess the effect of tumor volume on the enhancement pattern of parathyroid adenoma (PTA) on four-dimensional computed tomography (4D-CT). We analyzed the enhancement patterns of PTA on four-phase 4D-CT in 44 patients. Dependency of the changes of Hounsfield unit values (ΔHU) on the tumor volumes and clinical characteristics was evaluated using linear regression analyses. In addition, an unpaired t test was used to compare ΔHU of PTAs between PTA volume ≥1 cm{sup 3} and <1 cm{sup 3}, thyroid gland, and lymph node. PTA volume based on CT was the strongest factor on the ΔHU{sub Pre} {sub to} {sub Arterial} and ΔHU{sub Arterial} {sub to} {sub Venous} and ΔHU{sub Arterial} {sub to} {sub Delayed} (R {sup 2} = 0.34, 0.25, and 0.32, respectively, P < 0.001 for both). PTA ≥1 cm {sup 3} had statistically significant greater enhancement between the unenhanced phase and the arterial phase than PTA <1 cm {sup 3} (mean values ± standard deviations (SDs) of ΔHU{sub Pre} {sub to} {sub Arterial}, 102.7 ± 33.7 and 57.5 ± 28.8, respectively, P < 0.001). PTA ≥1 cm {sup 3} showed an early washout pattern on the venous phase, whereas PTA <1 cm {sup 3} showed a progressive enhancement pattern on the venous phase (mean values ± SDs of ΔHU{sub Arterial} {sub to} {sub Venous}, -13.2 ± 31.6 and 14.4 ± 32.7, respectively; P = 0.009). The enhancement pattern of PTA on 4D-CT is variable with respect to PTA volume based on CT. Therefore, the enhancement pattern of PTA on 4D-CT requires careful interpretation concerning the tumor volume, especially in cases of PTA <1 cm {sup 3}. (orig.)

  17. CARS 2009. Computer assisted radiology and surgery. Proceedings

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    The CARS 2009 proceedings include contributions and poster sessions concerning different conferences and workshops: computer assisted radiology, 23rd international congress and exhibition, CARS clinical day, 13th annual conference of the international society for computer aided surgery, 10th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, 11th international workshop on computer-aided diagnosis, 15th computed maxillofacial imaging congress, CARS - computer assisted radiology and surgery, 1st EPMA/CARS workshop on personalized medicine and ICT, JICARS - Japanese institutes of CARS, 1st EuroNotes/CTAC/CARS workshop on NOTES: an interdisciplinary challenge, 13th annual conference for computer aided surgery, 27th international EuroPACS meeting.

  18. Broadcast Copywriting and Computer Assisted Instruction.

    Science.gov (United States)

    Hagerman, William L.

    The teaching of broadcast copywriting can be enhanced by computer assisted instruction, especially in screening students' writing for adherence to classic "formulas" or "rules" for broadcast writing. Such rules might include avoiding cliches or not beginning a sentence with a subordinate clause. Other rules the computer can…

  19. Echocardiographic and non-gated computed tomographic findings of intrapericardial tumor and mediastinal tumor adjacent to the heart

    International Nuclear Information System (INIS)

    Ueda, Minoru; Yamada, Nobuyuki; Saito, Daiji; Haraoka, Shoichi; Tanetani, Setsuro.

    1981-01-01

    Echocardiographic and computed tomographic findings of a case of intrapericardial tumor are reported, and two other cases of mediastinal tumor are presented in a discussion of the differential diagnosis of intrapericardial from mediastinal tumors. Case report: A 7-year-old male complained of cough and dyspnea. Cardiomegaly had been pointed out at a mass X-ray examination about a month prior to the admission. Two-dimensional echocardiography revealed a massive anterior pericardial effusion and a fist-sized tumor with cystic structure. The tumor pushed the heart backward at the level of the aortic root. Non-gated computed tomography of the chest disclosed the size and location of the tumor, but failed to clarify the internal structure. The patient underwent successful removal of a tumor, 12 x 10 x 8 cm in size and 350 g in weight, originating from the left atrial wall. Histologically, the tumor was a fibrosarcomatous mesothelioma. Usually, an intrapericardial tumor is easily suspected by echocardiography by the presence of pericardial effusion, although there have been a few reports of intrapericardial tumors without pericardial effusion. Echocardiographic diagnosis of the intrapericardial tumor is difficult in such cases. Identification of the pericardium is necessary to diagnose whether a tumor is intra- or extrapericardial. This identification, however, is not always easy by echocardiography when the ultrasonic beams become tangent to the pericardium. The pericardium between the tumor and the heart could not be identified by echocardiography in our two cases of mediastinal tumor. Computed tomography is helpful in diagnosing the size and location of a mediastinal tumor. (author)

  20. Computer assisted SCFE osteotomy planning

    International Nuclear Information System (INIS)

    Drapikowski, Pawel; Tyrakowski, Marcin; Czubak, Jaroslaw; Czwojdzinski, Adam

    2008-01-01

    Slipped capital femoral epiphysis (SCFE) is a common pediatric orthopedic disorder that requires surgical correction. Preoperative planning of a proximal femoral osteotomy is essential in cases of SCFE. This planning is usually done using 2D radiographs, but 3D data can be acquired with CT and analyzed with 3D visualization software. SCFEanalyzer is a computer program developed for preoperative planning of proximal femoral osteotomy to correct SCFE. Computed tomography scans were performed on human bone specimens: one pelvis and two femoral bones (right and left) and volume data of a patient. The CT data were used to test the abilities of the SCFEanalyzer software, which utilizes 3D virtual models of anatomic structures constructed from CT image data. Separation of anatomical bone structures is done by means of ''cutting'' 3D surface model of the pelvis. The software enables qualitative and quantitative spatial analysis of chosen parameters analogous to those done on the basis of plain radiographs. SCFEanalyzer makes it possible to evaluate the function of the hip joint by calculating the range of motion depending on the shape of bone structures based on oriented bounding box object representation. Pelvic and hip CT scans from a patient with SCFE were subjected to femoral geometry analysis and hip joint function assessment. These were done to plan and simulate osteotomy of the proximal femur. Analogous qualitative and quantitative evaluation after performing the virtual surgery were evaluated to determine the potential treatment effects. The use of computer assistance in preoperative planning enable us to increase objectivity and repeatability, and to compare the results of different types of osteotomy on the proximal femur, and thus to choose the optimal operation in each individual case. (orig.)

  1. Computer assisted SCFE osteotomy planning

    Energy Technology Data Exchange (ETDEWEB)

    Drapikowski, Pawel [Poznan University of Technology, Institute of Control and Information Engineering, Poznan (Poland); Tyrakowski, Marcin; Czubak, Jaroslaw; Czwojdzinski, Adam [Postgraduate Medical Education Center, Department of Orthopaedics, Warsaw (Poland)

    2008-11-15

    Slipped capital femoral epiphysis (SCFE) is a common pediatric orthopedic disorder that requires surgical correction. Preoperative planning of a proximal femoral osteotomy is essential in cases of SCFE. This planning is usually done using 2D radiographs, but 3D data can be acquired with CT and analyzed with 3D visualization software. SCFEanalyzer is a computer program developed for preoperative planning of proximal femoral osteotomy to correct SCFE. Computed tomography scans were performed on human bone specimens: one pelvis and two femoral bones (right and left) and volume data of a patient. The CT data were used to test the abilities of the SCFEanalyzer software, which utilizes 3D virtual models of anatomic structures constructed from CT image data. Separation of anatomical bone structures is done by means of ''cutting'' 3D surface model of the pelvis. The software enables qualitative and quantitative spatial analysis of chosen parameters analogous to those done on the basis of plain radiographs. SCFEanalyzer makes it possible to evaluate the function of the hip joint by calculating the range of motion depending on the shape of bone structures based on oriented bounding box object representation. Pelvic and hip CT scans from a patient with SCFE were subjected to femoral geometry analysis and hip joint function assessment. These were done to plan and simulate osteotomy of the proximal femur. Analogous qualitative and quantitative evaluation after performing the virtual surgery were evaluated to determine the potential treatment effects. The use of computer assistance in preoperative planning enable us to increase objectivity and repeatability, and to compare the results of different types of osteotomy on the proximal femur, and thus to choose the optimal operation in each individual case. (orig.)

  2. Computer assisted pyeloplasty in children the retroperitoneal approach

    DEFF Research Database (Denmark)

    Olsen, L H; Jorgensen, T M

    2004-01-01

    PURPOSE: We describe the first series of computer assisted retroperitoneoscopic pyeloplasty in children using the Da Vinci Surgical System (Intuitive Surgical, Inc., Mountainview, California) with regard to setup, method, operation time, complications and preliminary outcome. The small space...... with the Da Vinci Surgical System. With the patient in a lateral semiprone position the retroperitoneal space was developed by blunt and balloon dissection. Three ports were placed for the computer assisted system and 1 for assistance. Pyeloplasty was performed with the mounted system placed behind...

  3. Computer assisted holographic moire contouring

    Science.gov (United States)

    Sciammarella, Cesar A.

    2000-01-01

    Theoretical analyses and experimental results on holographic moire contouring on diffusely reflecting objects are presented. The sensitivity and limitations of the method are discussed. Particular emphasis is put on computer-assisted data retrieval, processing, and recording.

  4. Influence of bladder and rectal volume on spatial variability of a bladder tumor during radical radiotherapy

    International Nuclear Information System (INIS)

    Pos, Floris J.; Koedooder, Kees; Hulshof, Maarten C.C.M.; Tienhoven, Geertjan van; Gonzalez Gonzalez, Dionisio

    2003-01-01

    Purpose: To assess the spatial variability of a bladder tumor relative to the planning target volume boundaries during radical radiotherapy, and furthermore to develop strategies to reduce spatial variability. Methods and Materials: Seventeen patients with solitary T2-T4N0M0 bladder cancer were treated with a technique delivering 40 Gy/2 Gy in 20 fractions to the whole bladder with a concomitant boost to the bladder tumor of 20 Gy in 1 Gy fractions in an overall time of 4 weeks. CT scans were made weekly, immediately after treatment, and matched with the planning CT scan. Spatial variability of the tumor, as well as bladder volume and rectal diameter, were scored for each patient each week. Results: In 65% of patients, a part of the tumor appeared outside the planning target volume boundaries at least one time during the course of radiotherapy. No consistent relation of this variability with time was found. Bladder volumes and rectal diameters showed marked variability during the course of treatment. A large initial bladder volume and rectal diameter predicted a large volume variation and a large tumor spatial variability. Conclusion: In this study, a margin of 1.5 to 2 cm seemed to be inadequate in 65% of the patients with respect to spatial variability. Bladder volume and rectal diameter were found to be predictive for spatial variability of a bladder tumor during concomitant boost radiotherapy

  5. Influence of bladder and rectal volume on spatial variability of a bladder tumor during radical radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Pos, Floris J; Koedooder, Kees; Hulshof, Maarten C.C.M.; Tienhoven, Geertjan van; Gonzalez Gonzalez, Dionisio

    2003-03-01

    Purpose: To assess the spatial variability of a bladder tumor relative to the planning target volume boundaries during radical radiotherapy, and furthermore to develop strategies to reduce spatial variability. Methods and Materials: Seventeen patients with solitary T2-T4N0M0 bladder cancer were treated with a technique delivering 40 Gy/2 Gy in 20 fractions to the whole bladder with a concomitant boost to the bladder tumor of 20 Gy in 1 Gy fractions in an overall time of 4 weeks. CT scans were made weekly, immediately after treatment, and matched with the planning CT scan. Spatial variability of the tumor, as well as bladder volume and rectal diameter, were scored for each patient each week. Results: In 65% of patients, a part of the tumor appeared outside the planning target volume boundaries at least one time during the course of radiotherapy. No consistent relation of this variability with time was found. Bladder volumes and rectal diameters showed marked variability during the course of treatment. A large initial bladder volume and rectal diameter predicted a large volume variation and a large tumor spatial variability. Conclusion: In this study, a margin of 1.5 to 2 cm seemed to be inadequate in 65% of the patients with respect to spatial variability. Bladder volume and rectal diameter were found to be predictive for spatial variability of a bladder tumor during concomitant boost radiotherapy.

  6. Medical image computing and computer science intervention. MICCAI 2005. Pt. 2. Proceedings

    International Nuclear Information System (INIS)

    Duncan, J.S.; Yale Univ., New Haven, CT; Gerig, G.

    2005-01-01

    The two-volume set LNCS 3749 and LNCS 3750 constitutes the refereed proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2005, held in Palm Springs, CA, USA, in October 2005. Based on rigorous peer reviews the program committee selected 237 carefully revised full papers from 632 submissions for presentation in two volumes. The first volume includes all the contributions related to image analysis and validation, vascular image segmentation, image registration, diffusion tensor image analysis, image segmentation and analysis, clinical applications - validation, imaging systems - visualization, computer assisted diagnosis, cellular and molecular image analysis, physically-based modeling, robotics and intervention, medical image computing for clinical applications, and biological imaging - simulation and modeling. The second volume collects the papers related to robotics, image-guided surgery and interventions, image registration, medical image computing, structural and functional brain analysis, model-based image analysis, image-guided intervention: simulation, modeling and display, and image segmentation and analysis. (orig.)

  7. Medical image computing and computer science intervention. MICCAI 2005. Pt. 2. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.S. [Yale Univ., New Haven, CT (United States). Dept. of Biomedical Engineering]|[Yale Univ., New Haven, CT (United States). Dept. of Diagnostic Radiology; Gerig, G. (eds.) [North Carolina Univ., Chapel Hill, NC (United States). Dept. of Computer Science

    2005-07-01

    The two-volume set LNCS 3749 and LNCS 3750 constitutes the refereed proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2005, held in Palm Springs, CA, USA, in October 2005. Based on rigorous peer reviews the program committee selected 237 carefully revised full papers from 632 submissions for presentation in two volumes. The first volume includes all the contributions related to image analysis and validation, vascular image segmentation, image registration, diffusion tensor image analysis, image segmentation and analysis, clinical applications - validation, imaging systems - visualization, computer assisted diagnosis, cellular and molecular image analysis, physically-based modeling, robotics and intervention, medical image computing for clinical applications, and biological imaging - simulation and modeling. The second volume collects the papers related to robotics, image-guided surgery and interventions, image registration, medical image computing, structural and functional brain analysis, model-based image analysis, image-guided intervention: simulation, modeling and display, and image segmentation and analysis. (orig.)

  8. Evaluation of potential internal target volume of liver tumors using cine-MRI.

    Science.gov (United States)

    Akino, Yuichi; Oh, Ryoong-Jin; Masai, Norihisa; Shiomi, Hiroya; Inoue, Toshihiko

    2014-11-01

    Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquired for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas-Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV Potential). The concordance between ITV Potential and ITV estimated with 4DCT (ITV 4DCT) was evaluated using the Dice's similarity coefficient (DSC). The distance between blood vessel positions

  9. SU-G-BRA-04: Simulation of Errors in Maximal Intensity Projection (MIP)-Based Lung Tumor Internal Target Volumes (ITV) Using Real-Time 2D MRI and Deformable Image Registration Based Lung Tumor Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, D; Kishan, A; Santhanam, A; Min, Y; O’Connell, D; Lamb, J; Cao, M; Agazaryan, N; Yang, Y; Lee, P; Low, D [University of California, Los Angeles, Ca (United States)

    2016-06-15

    Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the first frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric

  10. SU-G-BRA-04: Simulation of Errors in Maximal Intensity Projection (MIP)-Based Lung Tumor Internal Target Volumes (ITV) Using Real-Time 2D MRI and Deformable Image Registration Based Lung Tumor Tracking

    International Nuclear Information System (INIS)

    Thomas, D; Kishan, A; Santhanam, A; Min, Y; O’Connell, D; Lamb, J; Cao, M; Agazaryan, N; Yang, Y; Lee, P; Low, D

    2016-01-01

    Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the first frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric

  11. Peritumoral edema associated with metastatic brain tumor

    International Nuclear Information System (INIS)

    Shirotani, Toshiki; Takiguchi, Hiroshi; Shima, Katsuji; Chigasaki, Hiroo; Tajima, Atsushi; Watanabe, Satoru.

    1992-01-01

    Computed tomographic (CT) examinations were performed in 94 lesions of 50 patients with metastatic brain tumors. Peritumoral edema (A E ) and tumor area (A T ) were measured using the planimetric method on the CT scan films that demonstrated maximum size of the tumor. Then, the volume of the peritumoral edema (V E ) and the surface area of the tumor (S T ) were claculated from these data. Eighty-three brain lesions from lung cancers were subdivided into 49 adenocarcinomas, 11 squamous cell carcinomas, 16 small cell carcinomas and 7 large cell carcinomas. Eleven metastatic tumors from breast cancers were all adenocarcinomas. There was statistical correlation between the surface area of tumor and the volume of the peritumoral edema for the adenocarcinoma (r=0.4043, p E /S T ratios in small cell carcinomas were smaller then those in non-small cell carcinomas, when the volume of the tumor was larger than 10 mm 3 . Accordingly, we suggest that the volume of the peritumoral edema in the small cell carcinoma is generally smaller than that in others. (author)

  12. Multi-slice computed tomography-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma: a comparison with conventional microscopic transsphenoidal surgery.

    Science.gov (United States)

    Tosaka, Masahiko; Nagaki, Tomohito; Honda, Fumiaki; Takahashi, Katsumasa; Yoshimoto, Yuhei

    2015-11-01

    Intraoperative computed tomography (iCT) is a reliable method for the detection of residual tumour, but previous single-slice low-resolution computed tomography (CT) without coronal or sagittal reconstructions was not of adequate quality for clinical use. The present study evaluated the results of multi-slice iCT-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma. This retrospective study included 30 consecutive patients with newly diagnosed or recurrent pituitary macroadenoma with supradiaphragmatic extension who underwent endoscopic transsphenoidal surgery using iCT (eTSS+iCT group), and control 30 consecutive patients who underwent conventional endoscope-assisted transsphenoidal surgery (cTSS group). The tumour volume was calculated by multiplying the tumour area by the slice thickness. Visual acuity and visual field were estimated by the visual impairment score (VIS). The resection extent, (preoperative tumour volume - postoperative residual tumour volume)/preoperative tumour volume, was 98.9% (median) in the eTSS+iCT group and 91.7% in the cTSS group, and had significant difference between the groups (P = 0.04). Greater than 95 and >90% removal rates were significantly higher in the eTSS+iCT group than in the cTSS group (P = 0.02 and P = 0.001, respectively). However, improvement in VIS showed no significant difference between the groups. The rate of complications also showed no significant difference. Multi-slice iCT-assisted endoscopic transsphenoidal surgery may improve the resection extent of pituitary macroadenoma. Multi-slice iCT may have advantages over intraoperative magnetic resonance imaging in less expensive, short acquisition time, and that special protection against magnetic fields is not needed.

  13. MRI to delineate the gross tumor volume of nasopharyngeal cancers: which sequences and planes should be used?

    Science.gov (United States)

    Popovtzer, Aron; Ibrahim, Mohannad; Tatro, Daniel; Feng, Felix Y; Ten Haken, Randall K; Eisbruch, Avraham

    2014-09-01

    Magnetic resonance imaging (MRI) has been found to be better than computed tomography for defining the extent of primary gross tumor volume (GTV) in advanced nasopharyngeal cancer. It is routinely applied for target delineation in planning radiotherapy. However, the specific MRI sequences/planes that should be used are unknown. Twelve patients with nasopharyngeal cancer underwent primary GTV evaluation with gadolinium-enhanced axial T1 weighted image (T1) and T2 weighted image (T2), coronal T1, and sagittal T1 sequences. Each sequence was registered with the planning computed tomography scans. Planning target volumes (PTVs) were derived by uniform expansions of the GTVs. The volumes encompassed by the various sequences/planes, and the volumes common to all sequences/planes, were compared quantitatively and anatomically to the volume delineated by the commonly used axial T1-based dataset. Addition of the axial T2 sequence increased the axial T1-based GTV by 12% on average (p = 0.004), and composite evaluations that included the coronal T1 and sagittal T1 planes increased the axial T1-based GTVs by 30% on average (p = 0.003). The axial T1-based PTVs were increased by 20% by the additional sequences (p = 0.04). Each sequence/plane added unique volume extensions. The GTVs common to all the T1 planes accounted for 38% of the total volumes of all the T1 planes. Anatomically, addition of the coronal and sagittal-based GTVs extended the axial T1-based GTV caudally and cranially, notably to the base of the skull. Adding MRI planes and sequences to the traditional axial T1 sequence yields significant quantitative and anatomically important extensions of the GTVs and PTVs. For accurate target delineation in nasopharyngeal cancer, we recommend that GTVs be outlined in all MRI sequences/planes and registered with the planning computed tomography scans.

  14. Computer-assisted molecular modeling of tumor promoters: rationale for the activity of phorbol esters, teleocidin B, and aplysiatoxin

    International Nuclear Information System (INIS)

    Jeffrey, A.M.; Liskamp, R.M.J.

    1986-01-01

    In the two-stage model of skin carcinogenesis, it is believed that initiators bind to DNA and that tumor promoters such as phorbol 12-tetradecanoate 13-acetate (TPA) bind noncovalently to membrane-associated high-affinity receptors, probably protein kinase C. Two other types of potent tumor-promoting substances, aplysiatoxin and teleocidin, appear to act also by binding to and activating protein kinase C, even though their chemical structures are quite different. Therefore, the authors have undertaken computer modeling of the special relationship of various functional groups in these three chemical classes of tumor promoters in an attempt to explain how these diverse structures bind to the same receptor molecule. They propose a stereochemical model in which the oxygens in TPA at C-3, C-4, C-9, and C-20 (O-3, O-4, O-9, and O-20) correspond to the O-11, N-13, N-1, and O-24 positions in teleocidin and the O-27, O-3, O-11, and O-30 oxygens in aplysiatoxin, respectively. In this model all distances with respect to overlap of the corresponding atoms are <1 A. In addition, all three types of molecules have their hydrophobic moieties oriented in the similar position. This model is further discussed with respect to other compounds showing various degrees of activity as tumor promoters, including mezerein, ingenol, and 4α-TPA. The model explains how chemically diverse structures can have similar biological activity as tumor promoters and provides a basis for designing both agonists and antagonists of tumor promoters

  15. Incorporating computer-assisted assessment to Bachelor of Science ...

    African Journals Online (AJOL)

    The use of computers in education has already been established for decades. Computers have been used from lesson preparations, presentations, and student assessments. Many authors have studied the design, implementation, and impact of computer-assisted assessment (CAA) (also called computer-based testing, ...

  16. Accuracy of computer-assisted cervicle pedicle screw installation

    International Nuclear Information System (INIS)

    Zhang Honglei; Zhou Dongsheng; Jang Zhensong

    2009-01-01

    Objective: To investigate the accuracy of computer-assisted cervical pedicle screw installation and the reason of screw malposition. Methods: A total of 172 cervical pedicle screws were installed by computer-assisted navigation for 30 patients with lower cervical spinal diseases. All the patients were examined by X-ray and CT after operation. Screw's position and direction were measured on the sagittal and transectional images of intraoperative navigation and post-operative CT. Then linear regression analysis was taken between navigational and post-operative CT's images. Results: Two screws perforated the upper pedicle wall, 3 perforated the lateral pedicle wall.There was a positive linear correlation between navigational and post-operative CT's images. Conclusion: Computer-assisted navigation can provide the high accuracy of cervical pedicle screw installation and excursion phenomenon is reason of screw malposition. (authors)

  17. [Basic concept in computer assisted surgery].

    Science.gov (United States)

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  18. Utilizing Computer Integration to Assist Nursing

    OpenAIRE

    Hujcs, Marianne

    1990-01-01

    As the use of computers in health care continues to increase, methods of using these computers to assist nursing practice are also increasing. This paper describes how integration within a hospital information system (HIS) contributed to the development of a report format and computer generated alerts used by nurses. Discussion also includes how the report and alerts impact those nurses providing bedside care as well as how integration of an HIS creates challenges for nursing.

  19. Monitoring tumor motion with on-line mega-voltage cone-beam computed tomography imaging in a cine mode

    International Nuclear Information System (INIS)

    Reitz, Bodo; Gayou, Olivier; Parda, David S; Miften, Moyed

    2008-01-01

    Accurate daily patient localization is becoming increasingly important in external-beam radiotherapy (RT). Mega-voltage cone-beam computed tomography (MV-CBCT) utilizing a therapy beam and an on-board electronic portal imager can be used to localize tumor volumes and verify the patient's position prior to treatment. MV-CBCT produces a static volumetric image and therefore can only account for inter-fractional changes. In this work, the feasibility of using the MV-CBCT raw data as a fluoroscopic series of portal images to monitor tumor changes due to e.g. respiratory motion was investigated. A method was developed to read and convert the CB raw data into a cine. To improve the contrast-to-noise ratio on the MV-CB projection data, image post-processing with filtering techniques was investigated. Volumes of interest from the planning CT were projected onto the MV-cine. Because of the small exposure and the varying thickness of the patient depending on the projection angle, soft-tissue contrast was limited. Tumor visibility as a function of tumor size and projection angle was studied. The method was well suited in the upper chest, where motion of the tumor as well as of the diaphragm could be clearly seen. In the cases of patients with non-small cell lung cancer with medium or large tumor masses, we verified that the tumor mass was always located within the PTV despite respiratory motion. However for small tumors the method is less applicable, because the visibility of those targets becomes marginal. Evaluation of motion in non-superior-inferior directions might also be limited for small tumor masses. Viewing MV-CBCT data in a cine mode adds to the utility of MV-CBCT for verification of tumor motion and for deriving individualized treatment margins

  20. Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Stockmans Filip

    2010-12-01

    Full Text Available Abstract Background Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides. Methods/Design This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months

  1. Comparison of Tumor Volumes as Determined by Pathologic Examination and FDG-PET/CT Images of Non-Small-Cell Lung Cancer: A Pilot Study

    International Nuclear Information System (INIS)

    Yu Jinming; Li Xinke; Xing Ligang; Mu Dianbin; Fu Zheng; Sun Xiaorong; Sun Xiangyu; Yang Guoren; Zhang Baijiang; Sun Xindong; Ling, C. Clifton

    2009-01-01

    Purpose: To determine the cut-off standardized uptake value (SUV) on 18 F fluoro-2-deoxy-glucose (FDG) positron emission tomography/computed tomography (FDG-PET/CT) images that generates the best volumetric match to pathologic gross tumor volume (GTV path ) for non-small-cell lung cancer (NSCLC). Methods and Materials: Fifteen patients with NSCLC who underwent FDG-PET/CT scans followed by lobectomy were enrolled. The surgical specimen was dissected into 5-7-μm sections at approximately 4-mm intervals and stained with hematoxylin and eosin. The tumor-containing area was outlined slice by slice and the GTV path determined by summing over all the slices, taking into account the interslice thickness and fixation-induced volume reduction. The gross tumor volume from the PET images, GTV PET , was determined as a function of cut-off SUV. The optimal threshold or optimal absolute SUV was defined as the value at which the GTV PET was the same as the GTV path . Results: The fixation process induced a volumetric reduction to 82% ± 10% (range, 62-100%) of the original. The maximal SUV was 10.1 ± 3.6 (range, 4.2-18.7). The optimal threshold and absolute SUV were 31% ± 11% and 3.0 ± 1.6, respectively. The optimal threshold was inversely correlated with GTV path and tumor diameter (p path or tumor diameter (p > 0.05). Conclusion: This study evaluated the use of GTV path as a criterion for determining the optimal cut-off SUV for NSCLC target volume delineation. Confirmatory studies including more cases are being performed.

  2. Hybrid video-assisted and limited open (VALO) resection of superior sulcus tumors.

    Science.gov (United States)

    Nun, Alon Ben; Simansky, David; Rokah, Merav; Zeitlin, Nona; Avi, Roni Ben; Soudack, Michalle; Golan, Nir; Apel, Sarit; Bar, Jair; Yelin, Alon

    2016-06-01

    To compare the postoperative recovery of patients with superior sulcus tumors (Pancoast tumors) following conventional open surgery vs. a hybrid video-assisted and limited open approach (VALO). The subjects of this retrospective study were 20 patients we operated on to resect a Pancoast tumor. All patients received induction chemo-radiation followed by surgery, performed via either a conventional thoracotomy approach (n = 10) or the hybrid VALO approach (n = 10). In the hybrid VALO group, lobectomy and internal chest wall preparation were performed using a video technique, with rib resection and specimen removal through a limited incision. There was no mortality in either group. Two patients from the thoracotomy group required mechanical ventilation, but there was no major morbidity in the hybrid VALO group. The operative times were similar for the two procedures. The average length of hospital stay was shorter and the average pain scores were significantly lower in the hybrid VALO group. The incidence of chronic pain was 10 % in the hybrid VALO group vs. 50 % in the thoracotomy group. Hybrid VALO resection of Pancoast tumors is feasible and safe, resulting in faster patient recovery and a significantly lower incidence of severe chronic pain than open thoracotomy. We conclude that centers experienced with video-assisted lobectomy should consider hybrid VALO surgery as the procedure of choice for Pancoast tumors.

  3. Plasma uric acid and tumor volume are highly predictive of outcome in nasopharyngeal carcinoma patients receiving intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Lin, Hui; Lin, Huan-Xin; Ge, Nan; Wang, Hong-Zhi; Sun, Rui; Hu, Wei-Han

    2013-01-01

    The combined predictive value of plasma uric acid and primary tumor volume in nasopharyngeal carcinoma (NPC) patients receiving intensity modulated radiation therapy (IMRT) has not yet been determined. In this retrospective study, plasma uric acid level was measured after treatment in 130 histologically-proven NPC patients treated with IMRT. Tumor volume was calculated from treatment planning CT scans. Overall (OS), progression-free (PFS) and distant metastasis-free (DMFS) survival were compared using Kaplan-Meier analysis and the log rank test, and Cox multivariate and univariate regression models were created. Patients with a small tumor volume (<27 mL) had a significantly better DMFS, PFS and OS than patients with a large tumor volume. Patients with a high post-treatment plasma uric acid level (>301 μmol/L) had a better DMFS, PFS and OS than patients with a low post-treatment plasma uric acid level. Patients with a small tumor volume and high post-treatment plasma uric acid level had a favorable prognosis compared to patients with a large tumor volume and low post-treatment plasma uric acid level (7-year overall OS, 100% vs. 48.7%, P <0.001 and PFS, 100% vs. 69.5%, P <0.001). Post-treatment plasma uric acid level and pre-treatment tumor volume have predictive value for outcome in NPC patients receiving IMRT. NPC patients with a large tumor volume and low post-treatment plasma uric acid level may benefit from additional aggressive treatment after IMRT

  4. Interobserver and Intraobserver Reproducibility with Volume Dynamic Contrast Enhanced Computed Tomography (DCE-CT) in Gastroesophageal Junction Cancer

    DEFF Research Database (Denmark)

    Lundsgaard Hansen, Martin; Fallentin, Eva; Axelsen, Thomas

    2016-01-01

    -dimensional (2D) fixed ROIs) placed in the tumor periphery, (II) 2-dimensional regions of interest (2D-ROI) along the tumor border in the tumor center, and (III) 3-dimensional volumes of interest (3D-VOI) containing the entire tumor volume. Arterial flow, blood volume and permeability (k(trans)) were recorded...

  5. Dose escalation to high-risk sub-volumes based on non-invasive imaging of hypoxia and glycolytic activity in canine solid tumors

    DEFF Research Database (Denmark)

    Clausen, Malene M.; Hansen, Anders Elias; af Rosenschold, Per Munck

    2013-01-01

    : Positron emission tomography/computed tomography (PET/CT) scans of five spontaneous canine solid tumors were included. FDG-PET/CT was obtained at day 1, 64Cu-ATSM at day 2 and 3 (3 and 24 h pi.). GTV was delineated and CT images were co-registered. Sub-volumes for 3 h and 24 h 64Cu-ATSM (Cu3 and Cu24) were...

  6. Improved computer-assisted nuclear imaging in renovascular hypertension

    International Nuclear Information System (INIS)

    Gross, M.L.; Nally, J.V.; Potvini, W.J.; Clarke, H.S. Jr.; Higgins, J.T.; Windham, J.P.

    1985-01-01

    A computer-assisted program with digital background subtraction has been developed to analyze the initial 90 second Tc-99m DTPA renal flow scans in an attempt to quantitate the early isotope delivery to and uptake by the kidney. This study was designed to compare the computer-assisted 90 second DTPA scan with the conventional 30 minute I-131 Hippuran scan. Six patients with angiographically-proven unilateral renal artery stenosis were studied. The time activity curves for both studies were derived from regions of interest selected from the computer acquired dynamic images. The following parameters were used to assess renal blood flow: differential maximum activity, minimum/maximum activity ratio, and peak width. The computer-assisted DTPA study accurately predicted (6/6) the stenosed side documented angiographically, whereas the conventional Hippuran scan was clearly predictive in only 2/6. In selected cases successfully corrected surgically, the DTPA study proved superior in assessing the degree of patency of the graft. The best discriminatory factors when compared to a template synthesized from curves obtained from normal subjects were differential maximum activity and peak width. The authors conclude that: 1) the computer-assisted 90 second DTPA renal blood flow scan was superior to the conventional I-131 Hippuran scan in demonstrating unilateral reno-vascular disease; 2) the DTPA study was highly predictive of the angiographic findings; and 3) this non-invasive study should prove useful in the diagnosis and serial evaluation following surgery and/or angioplasty for renal artery stenosis

  7. Computer-Assisted Evaluation of Videokymographic Data

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Sedlář, Jiří; Zita, A.; Švec, J. G.; Zitová, Barbara; Flusser, Jan; Hauzar, D.

    2013-01-01

    Roč. 1, č. 1 (2013), s. 49-49 ISSN 1805-8698. [EFMI STC Prague Data and Knowledge for Medical Decision Support. 17.04.2013-19.04.2013, Praha] Institutional support: RVO:67985556 Keywords : videokymography * image process ing * computerassisted evaluation Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2013/ZOI/novozamsky-computer-assisted evaluation of videokymographic data.pdf

  8. To EDF: PHOEBUS, computer-assisted engineering

    International Nuclear Information System (INIS)

    Lecocq, P.; Goudal, J.C.; Barache, J.M.; Feingold, D.; Cornon, P.

    1986-01-01

    EDF has built a modular integrated computer-assisted nuclear engineering (CAE) system called POEBUS. Since 1975, the Organization has been interested in CAE which places computer methods and technology at the disposal of the engineering department. This paper describes the changes and their effect on the techniques in use, working methods and the personnel called on to put them into operation [fr

  9. Comparison of radionuclide scans with computer-assisted tomography in diagnosis of intracranial disease

    International Nuclear Information System (INIS)

    Clifford, J.R.; Connolly, E.S.; Voorhies, R.M.

    1976-01-01

    Radionuclide brain scans were compared with computer-assisted tomography (CAT) for the diagnosis of intracranial disorders in 297 patients. The diagnosis was confirmed in 281 patients who formed the population for the study. The radionuclide scan was false positive for 12 patients (3.9 percent) and false negative for eight (2.6 percent). The CAT was false positive for three patients (1 percent) and false negative for one (0.3 percent). In the 133 patients in whom both tests were negative, no evidence of central nervous system pathology has been found during the 6 to 18 month follow-up. Brain tumors and intracerebral hemorrhage are more readily detectable with CAT

  10. Fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density

    Energy Technology Data Exchange (ETDEWEB)

    Baldy, R.E.; Brindley, G.S.; Jacobson, R.R.; Reveley, M.A.; Lishman, W.A.; Ewusi-Mensah, I.; Turner, S.W.

    1986-03-01

    Computer-assisted methods of CT brain scan analysis offer considerable advantages over visual inspection, particularly in research; and several semi-automated methods are currently available. A new computer-assisted program is presented which provides fully automated processing of CT brain scans, depending on ''anatomical knowledge'' of where cerebrospinal fluid (CSF)-containing spaces are likely to lie. After identifying these regions of interest quantitative estimates are then provided of CSF content in each slice in cisterns, ventricles, Sylvian fissure and interhemispheric fissure. Separate measures are also provided of mean brain density in each slice. These estimates can be summated to provide total ventricular and total brain volumes. The program shows a high correlation with measures derived from mechanical planimetry and visual grading procedures, also when tested against a phantom brain of known ventricular volume. The advantages and limitations of the present program are discussed.

  11. Distribution of Functional Liver Volume in Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus in the 1st Branch and Main Trunk Using Single Photon Emission Computed Tomography—Application to Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Akira Ikoma

    2011-10-01

    Full Text Available Purpose: To analyze the distribution of functional liver volume (FLV in the margin volume (MV surrounding hepatocellular carcinoma (HCC with portal vein tumor thrombus (PVTT before radiation therapy (RT and to verify the safety of single photon emission computed tomography-based three-dimensional conformal radiotherapy (SPECT-B3DCRT by exploring the relation of FLV in MV to radiation-induced liver disease (RILD. Methods and Materials: Clinical target volume (CTV included main tumor and PVTT, and planning target volume (PTV included CTV with a 10 mm margin. MV was defined as PTV–CTV. FLV ratio in MV was calculated as FLV in MV/MV × 100 (%. The two high-dose beams were planned to irradiate FLV as little as possible. Fifty-seven cases of HCC (26/57, 46%; Child–Pugh grade B with PVTT underwent SPECT-B3DCRT which targeted the CTV to a total dose of 45 Gy/18 fractions. The destructive ratio was defined as radiation induced dysfunctional volume/FLV × 100 (%. Results: We observed a significant negative correlation between FLV ratio in MV and CTV (p < 0.001. Three cases with CTVs of 287, 587 and 1184 cm3 experienced transient RILD. The FLV ratio in MV was highest in patients with RILD: nine patients with CTV of 200–300 cm3, three with CTV of 500–600 cm3, and two with CTV of 1100–1200 cm3. The destructive ratio yielded a mean value of 24.2 ± 1.5%. Conclusions: Radiation planning that takes into account the distribution of FLV appears to result in the least possible RILD.

  12. Three-dimensional lung tumor segmentation from x-ray computed tomography using sparse field active models.

    Science.gov (United States)

    Awad, Joseph; Owrangi, Amir; Villemaire, Lauren; O'Riordan, Elaine; Parraga, Grace; Fenster, Aaron

    2012-02-01

    Manual segmentation of lung tumors is observer dependent and time-consuming but an important component of radiology and radiation oncology workflow. The objective of this study was to generate an automated lung tumor measurement tool for segmentation of pulmonary metastatic tumors from x-ray computed tomography (CT) images to improve reproducibility and decrease the time required to segment tumor boundaries. The authors developed an automated lung tumor segmentation algorithm for volumetric image analysis of chest CT images using shape constrained Otsu multithresholding (SCOMT) and sparse field active surface (SFAS) algorithms. The observer was required to select the tumor center and the SCOMT algorithm subsequently created an initial surface that was deformed using level set SFAS to minimize the total energy consisting of mean separation, edge, partial volume, rolling, distribution, background, shape, volume, smoothness, and curvature energies. The proposed segmentation algorithm was compared to manual segmentation whereby 21 tumors were evaluated using one-dimensional (1D) response evaluation criteria in solid tumors (RECIST), two-dimensional (2D) World Health Organization (WHO), and 3D volume measurements. Linear regression goodness-of-fit measures (r(2) = 0.63, p < 0.0001; r(2) = 0.87, p < 0.0001; and r(2) = 0.96, p < 0.0001), and Pearson correlation coefficients (r = 0.79, p < 0.0001; r = 0.93, p < 0.0001; and r = 0.98, p < 0.0001) for 1D, 2D, and 3D measurements, respectively, showed significant correlations between manual and algorithm results. Intra-observer intraclass correlation coefficients (ICC) demonstrated high reproducibility for algorithm (0.989-0.995, 0.996-0.997, and 0.999-0.999) and manual measurements (0.975-0.993, 0.985-0.993, and 0.980-0.992) for 1D, 2D, and 3D measurements, respectively. The intra-observer coefficient of variation (CV%) was low for algorithm (3.09%-4.67%, 4.85%-5.84%, and 5

  13. Tumor Volume Changes Assessed by Three-Dimensional Magnetic Resonance Volumetry in Rectal Cancer Patients After Preoperative Chemoradiation: The Impact of the Volume Reduction Ratio on the Prediction of Pathologic Complete Response

    International Nuclear Information System (INIS)

    Kang, Jeong Hyun; Kim, Young Chul; Kim, Hyunki; Kim, Young Wan; Hur, Hyuk; Kim, Jin Soo; Min, Byung Soh; Kim, Hogeun; Lim, Joon Seok; Seong, Jinsil; Keum, Ki Chang; Kim, Nam Kyu

    2010-01-01

    Purpose: The aim of this study was to determine the correlation between tumor volume changes assessed by three-dimensional (3D) magnetic resonance (MR) volumetry and the histopathologic tumor response in rectal cancer patients undergoing preoperative chemoradiation therapy (CRT). Methods and Materials: A total of 84 patients who underwent preoperative CRT followed by radical surgery were prospectively enrolled in the study. The post-treatment tumor volume and tumor volume reduction ratio (% decrease ratio), as shown by 3D MR volumetry, were compared with the histopathologic response, as shown by T and N downstaging and the tumor regression grade (TRG). Results: There were no significant differences in the post-treatment tumor volume and the volume reduction ratio shown by 3D MR volumetry with respect to T and N downstaging and the tumor regression grade. In a multivariate analysis, the tumor volume reduction ratio was not significantly associated with T and N downstaging. The volume reduction ratio (>75%, p = 0.01) and the pretreatment carcinoembryonic antigen level (≤3 ng/ml, p = 0.01), but not the post-treatment volume shown by 3D MR (≤ 5ml), were, however, significantly associated with an increased pathologic complete response rate. Conclusion: More than 75% of the tumor volume reduction ratios were significantly associated with a high pathologic complete response rate. Therefore, limited treatment options such as local excision or simple observation might be considered after preoperative CRT in this patient population.

  14. Comparison of six methods of segmentation of tumor volume on the 18F-F.D.G. PET scan with reference histological volume in non small cell bronchopulmonary cancers

    International Nuclear Information System (INIS)

    Venel, Y.; Garhi, H.; Baulieu, J.L.; Prunier-Aesch, C.; Muret, A. de; Barillot, I.

    2008-01-01

    The 18 F-F.D.G. PET has demonstrated its importance in oncology, for initial extension and efficacy of anti tumoral therapeutics. Several studies have attempted to prove its utility to define tumoral volumes for conformational radiotherapy in non small cell lung cancers. Some authors have suggested the use of threshold of tumor intensity uptake with 40 or 50% of maximal intensity. Black et al. have determined contouring with linear regression formula of mean semi-quantitative index of tumor uptake (standard uptake value): SUV threshold = 0.307 Sub average + 0.588. Nestle et al. have taken into account the background noise intensity and mean intensity of the tumor: I threshold = β I average +I noise with β 0.15. Our study was done in collaboration with Inserm U618 team and has compared volumes defined on PET scan defined according to different methods based on intensity or S.U.V. to the tumour volume determined on CT scan by radio physicist. We have compared those volumes with histological volume that we considered for reference. Four patients have been included. They had 18 F-F.D.G. PET scan followed by complete tumoral removal surgery. Specific histological procedure allowed to define complete size of the tumor in re expanded lung. Comparatively to pathology, the volumes obtained using I max 40 and I max 50 are all underestimated. The volumes defined by Black's et al. method are under evaluated for the two largest tumours (15.8% to 22%) and overestimated for the two smallest ones (17.9 to 82.9%). Nestle's et al. method, using β = 0.15, correctly estimates two tumor volumes over 2 cm, but overestimates the two small tumors (79.6 to 124%). Finally, the corrected Nestle's et al. formula (using β = 0.264) overestimates three tumours. Volumes defined on CT scan by radio physicist are correct for one lesion, underestimated for one and overestimated for two other ones (44 and 179.5%). Nestle's et al. method seems to be the most accurate for tumours over 2 cm of

  15. Observation of Interfractional Variations in Lung Tumor Position Using Respiratory Gated and Ungated Megavoltage Cone-Beam Computed Tomography

    International Nuclear Information System (INIS)

    Chang, Jenghwa; Mageras, Gig S.; Yorke, Ellen; De Arruda, Fernando; Sillanpaa, Jussi; Rosenzweig, Kenneth E.; Hertanto, Agung; Pham, Hai; Seppi, Edward; Pevsner, Alex; Ling, C. Clifton; Amols, Howard

    2007-01-01

    Purpose: To evaluate the use of megavoltage cone-beam computed tomography (MV CBCT) to measure interfractional variation in lung tumor position. Methods and Materials: Eight non-small-cell lung cancer patients participated in the study, 4 with respiratory gating and 4 without. All patients underwent MV CBCT scanning at weekly intervals. Contoured planning CT and MV CBCT images were spatially registered based on vertebral anatomy, and displacements of the tumor centroid determined. Setup error was assessed by comparing weekly portal orthogonal radiographs with digitally reconstructed radiographs generated from planning CT images. Hypothesis testing was performed to test the statistical significance of the volume difference, centroid displacement, and setup uncertainty. Results: The vertebral bodies and soft tissue portions of tumor within lung were visible on the MV CBCT scans. Statistically significant systematic volume decrease over the course of treatment was observed for 1 patient. The average centroid displacement between simulation CT and MV CBCT scans were 2.5 mm, -2.0 mm, and -1.5 mm with standard deviations of 2.7 mm, 2.7 mm, and 2.6 mm in the right-left, anterior-posterior and superior-inferior directions. The mean setup errors were smaller than the centroid shifts, while the standard deviations were comparable. In most cases, the gross tumor volume (GTV) defined on the MV CBCT was located on average at least 5 mm inside a 10 mm expansion of the GTV defined on the planning CT scan. Conclusions: The MV CBCT technique can be used to image lung tumors and may prove valuable for image-guided radiotherapy. Our conclusions must be verified in view of the small patient number

  16. Computer assisted diagnosis of benign bone tumours

    International Nuclear Information System (INIS)

    Samardziski, M.; Zafiroski, G.; Janevska, V.; Miladinova, D.; Popeska, Z.

    2004-01-01

    Background. The aim of this study is to determine the correlation between computer-assisted diagnosis (CAD) of benign bone tumours (BBT) and their histological type. Patients and method. Altogether 120 patients were included in two groups. The retrospective group comprised 68 patients in whom the histological type of BBT was known prior to computer analysis. The prospective group comprised 52 patients in whom the histological type of BBT was unknown prior to computer analysis. Computer program was efficient and easy to use. Results. Average percent of histological type confirmed with CAD in the retrospective and prospective groups was 72.06% and 76.92%, respectively. Histological confirmation of CAD in specific BBT was 91.42% for enchondroma, 96.15% for osteoid-osteoma, and 98.08% for osteochondroma. Significantly lower percentage of CAD confirmation of fibroma, chondromixoid fibroma, osteoclastoma, desmoplastic fibroma and osteobalstoma due to their adverse biological character or complex anatomic localization is understandable. Conclusions. The results speak in favour of the assumption that computer assisted diagnosis of bone tumours program may improve the diagnostic accuracy of the examiner. (author)

  17. Evaluation of potential internal target volume of liver tumors using cine-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Akino, Yuichi, E-mail: akino@radonc.med.osaka-u.ac.jp [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 5650871, Japan and Miyakojima IGRT Clinic, Miyakojima-ku, Osaka 5340021 (Japan); Oh, Ryoong-Jin; Masai, Norihisa; Shiomi, Hiroya; Inoue, Toshihiko [Miyakojima IGRT Clinic, Miyakojima-ku, Osaka 5340021 (Japan)

    2014-11-01

    Purpose: Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. Methods: The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquired for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas–Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV {sub Potential}). The concordance between ITV {sub Potential} and ITV estimated with 4DCT (ITV {sub 4DCT}) was evaluated using the Dice’s similarity coefficient (DSC). Results

  18. Three-dimensional reconstruction volume: a novel method for volume measurement in kidney cancer.

    Science.gov (United States)

    Durso, Timothy A; Carnell, Jonathan; Turk, Thomas T; Gupta, Gopal N

    2014-06-01

    The role of volumetric estimation is becoming increasingly important in the staging, management, and prognostication of benign and cancerous conditions of the kidney. We evaluated the use of three-dimensional reconstruction volume (3DV) in determining renal parenchymal volumes (RPV) and renal tumor volumes (RTV). We compared 3DV with the currently available methods of volume assessment and determined its interuser reliability. RPV and RTV were assessed in 28 patients who underwent robot-assisted laparoscopic partial nephrectomy for kidney cancer. Patients with a preoperative creatinine level of kidney pre- and postsurgery overestimated 3D reconstruction volumes by 15% to 102% and 12% to 101%, respectively. In addition, volumes obtained from 3DV displayed high interuser reliability regardless of experience. 3DV provides a highly reliable way of assessing kidney volumes. Given that 3DV takes into account visible anatomy, the differences observed using previously published methods can be attributed to the failure of geometry to accurately approximate kidney or tumor shape. 3DV provides a more accurate, reproducible, and clinically useful tool for urologists looking to improve patient care using analysis related to volume.

  19. Characterizing Tumor Heterogeneity With Functional Imaging and Quantifying High-Risk Tumor Volume for Early Prediction of Treatment Outcome: Cervical Cancer as a Model

    International Nuclear Information System (INIS)

    Mayr, Nina A.; Huang Zhibin; Wang, Jian Z.; Lo, Simon S.; Fan, Joline M.; Grecula, John C.; Sammet, Steffen; Sammet, Christina L.; Jia Guang; Zhang Jun; Knopp, Michael V.; Yuh, William T.C.

    2012-01-01

    Purpose: Treatment response in cancer has been monitored by measuring anatomic tumor volume (ATV) at various times without considering the inherent functional tumor heterogeneity known to critically influence ultimate treatment outcome: primary tumor control and survival. This study applied dynamic contrast-enhanced (DCE) functional MRI to characterize tumors' heterogeneous subregions with low DCE values, at risk for treatment failure, and to quantify the functional risk volume (FRV) for personalized early prediction of treatment outcome. Methods and Materials: DCE-MRI was performed in 102 stage IB 2 –IVA cervical cancer patients to assess tumor perfusion heterogeneity before and during radiation/chemotherapy. FRV represents the total volume of tumor voxels with critically low DCE signal intensity ( 20, >13, and >5 cm 3 , respectively, significantly predicted unfavorable 6-year primary tumor control (p = 0.003, 7.3 × 10 −8 , 2.0 × 10 −8 ) and disease-specific survival (p = 1.9 × 10 −4 , 2.1 × 10 −6 , 2.5 × 10 −7 , respectively). The FRVs were superior to the ATVs as early predictors of outcome, and the differentiating power of FRVs increased during treatment. Discussion: Our preliminary results suggest that functional tumor heterogeneity can be characterized by DCE-MRI to quantify FRV for predicting ultimate long-term treatment outcome. FRV is a novel functional imaging heterogeneity parameter, superior to ATV, and can be clinically translated for personalized early outcome prediction before or as early as 2–5 weeks into treatment.

  20. Comparison of six methods of segmentation of tumor volume on the {sup 18}F-F.D.G. PET scan with reference histological volume in non small cell bronchopulmonary cancers; Comparaison de six methodes de segmentation du volume tumoral sur la {sup 18}F-FDG TEP-TDM avec le volume de reference anatomopathologique dans les cancers bronchopulmonaires non a petites cellules

    Energy Technology Data Exchange (ETDEWEB)

    Venel, Y.; Garhi, H.; Baulieu, J.L.; Prunier-Aesch, C. [CHRU de Tours-Bretonneau, Service de Medecine Nucleaire, 37 - Tours (France); Muret, A. de [CHRU de Tours-Bretonneau, Service de Radiotherapie, 37 - Tours (France); Barillot, I. [CHRU de Tours-Bretonneau, Service d' Anatomopathologie, 37 - Tours (France)

    2008-06-15

    The {sup 18}F-F.D.G. PET has demonstrated its importance in oncology, for initial extension and efficacy of anti tumoral therapeutics. Several studies have attempted to prove its utility to define tumoral volumes for conformational radiotherapy in non small cell lung cancers. Some authors have suggested the use of threshold of tumor intensity uptake with 40 or 50% of maximal intensity. Black et al. have determined contouring with linear regression formula of mean semi-quantitative index of tumor uptake (standard uptake value): SUV{sub threshold} = 0.307 Sub{sub average} + 0.588. Nestle et al. have taken into account the background noise intensity and mean intensity of the tumor: I{sub threshold} = {beta} I{sub average} +I{sub noise} with {beta} 0.15. Our study was done in collaboration with Inserm U618 team and has compared volumes defined on PET scan defined according to different methods based on intensity or S.U.V. to the tumour volume determined on CT scan by radio physicist. We have compared those volumes with histological volume that we considered for reference. Four patients have been included. They had {sup 18}F-F.D.G. PET scan followed by complete tumoral removal surgery. Specific histological procedure allowed to define complete size of the tumor in re expanded lung. Comparatively to pathology, the volumes obtained using I{sub max} 40 and I{sub max} 50 are all underestimated. The volumes defined by Black's et al. method are under evaluated for the two largest tumours (15.8% to 22%) and overestimated for the two smallest ones (17.9 to 82.9%). Nestle's et al. method, using {beta} = 0.15, correctly estimates two tumor volumes over 2 cm, but overestimates the two small tumors (79.6 to 124%). Finally, the corrected Nestle's et al. formula (using {beta} = 0.264) overestimates three tumours. Volumes defined on CT scan by radio physicist are correct for one lesion, underestimated for one and overestimated for two other ones (44 and 179.5%). Nestle

  1. Pulmonary tumor measurements from x-ray computed tomography in one, two, and three dimensions.

    Science.gov (United States)

    Villemaire, Lauren; Owrangi, Amir M; Etemad-Rezai, Roya; Wilson, Laura; O'Riordan, Elaine; Keller, Harry; Driscoll, Brandon; Bauman, Glenn; Fenster, Aaron; Parraga, Grace

    2011-11-01

    We evaluated the accuracy and reproducibility of three-dimensional (3D) measurements of lung phantoms and patient tumors from x-ray computed tomography (CT) and compared these to one-dimensional (1D) and two-dimensional (2D) measurements. CT images of three spherical and three irregularly shaped tumor phantoms were evaluated by three observers who performed five repeated measurements. Additionally, three observers manually segmented 29 patient lung tumors five times each. Follow-up imaging was performed for 23 tumors and response criteria were compared. For a single subject, imaging was performed on nine occasions over 2 years to evaluate multidimensional tumor response. To evaluate measurement accuracy, we compared imaging measurements to ground truth using analysis of variance. For estimates of precision, intraobserver and interobserver coefficients of variation and intraclass correlations (ICC) were used. Linear regression and Pearson correlations were used to evaluate agreement and tumor response was descriptively compared. For spherical shaped phantoms, all measurements were highly accurate, but for irregularly shaped phantoms, only 3D measurements were in high agreement with ground truth measurements. All phantom and patient measurements showed high intra- and interobserver reproducibility (ICC >0.900). Over a 2-year period for a single patient, there was disagreement between tumor response classifications based on 3D measurements and those generated using 1D and 2D measurements. Tumor volume measurements were highly reproducible and accurate for irregular, spherical phantoms and patient tumors with nonuniform dimensions. Response classifications obtained from multidimensional measurements suggest that 3D measurements provide higher sensitivity to tumor response. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  2. Perioperative outcomes of zero ischemia radiofrequency ablation-assisted tumor enucleation for renal cell carcinoma: results of 182 patients.

    Science.gov (United States)

    Zhang, Chengwei; Zhao, Xiaozhi; Guo, Suhan; Ji, Changwei; Wang, Wei; Guo, Hongqian

    2018-05-15

    To evaluate the perioperative outcomes of zero ischemia radiofrequency ablation-assisted tumor enucleation. Patients undergoing zero ischemia radiofrequency ablation-assisted tumor enucleation were retrospectively identified from July 2008 to March 2013. The tumor was enucleated after RFA treatment. R.E.N.A.L., PADUA and centrality index (C-index) score systems were used to assess each tumor case. We analyzed the correlation of perioperative outcomes with these scores. Postoperative complications were graded with Clavien-Dindo system. Multivariate logistic regression analyses were used to assess risk of complications. Among 182 patients assessed, median tumor size, estimated blood loss, hospital stay and operative time were 3.2 cm (IQR 2.8-3.4), 80 ml (IQR 50-120), 7 days (IQR 6-8) and 100 min (IQR 90-120), respectively. All three scoring systems were strongly correlated with estimated blood loss, hospital stay and operative time. We found 3 (1.6%) intraoperative and 23 (12.6%, 13 [7.1%] Grade 1 and 10 [5.5%] Grade 2 & 3a) postoperative complications. The median follow-up was 55.5 months (IQR 45-70). Additionally, the complexities of R.E.N.A.L., PADUA and C-index scores were significantly correlated with complication grades (P radiofrequency ablation-assisted tumor enucleation is considered an effective nephron-sparing treatment. Scoring systems could be useful for predicting perioperative outcomes of radiofrequency ablation-assisted tumor enucleation.

  3. A fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density

    International Nuclear Information System (INIS)

    Baldy, R.E.; Brindley, G.S.; Jacobson, R.R.; Reveley, M.A.; Lishman, W.A.; Ewusi-Mensah, I.; Turner, S.W.

    1986-01-01

    Computer-assisted methods of CT brain scan analysis offer considerable advantages over visual inspection, particularly in research; and several semi-automated methods are currently available. A new computer-assisted program is presented which provides fully automated processing of CT brain scans, depending on ''anatomical knowledge'' of where cerebrospinal fluid (CSF)-containing spaces are likely to lie. After identifying these regions of interest quantitative estimates are then provided of CSF content in each slice in cisterns, ventricles, Sylvian fissure and interhemispheric fissure. Separate measures are also provided of mean brain density in each slice. These estimates can be summated to provide total ventricular and total brain volumes. The program shows a high correlation with measures derived from mechanical planimetry and visual grading procedures, also when tested against a phantom brain of known ventricular volume. The advantages and limitations of the present program are discussed. (orig.)

  4. Evaluation of primary neck tumors by computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Keiko

    1983-01-01

    Application of computed tomography (CT) to neck tumors has received little attention. 40 CT scans of primary neck tumors were reviewed, and CT was proved to be extremely useful in the diagnosis and definition of extension of primary neck tumors. In the carotid triangle and sternocleidomastoid region 2nd branchial cysts, cystic hygromas and tuberculous lymphadenitis are included in the differential diagnosis of cystic tumors. In the carotid triangle markedly enhanced solid tumors must be paragangliomas, i.e. carotid body tumors, if they are located posteromedial to the carotid artery. And moderately enhanced tumors are neurilemmomas arising from sympathetic or vagus nerve. It is easy to define enlarged deep jugular lymph nodes because they are located lateral to the carotid artery. In the supraclavicular fossa enlarged lymph nodes can be differentiated from neurilemmomas of branchial plexus because enlarged lymph nodes are located anterior to subclavian vessels or anterior scalene muscle and branchial neurilemmomas are located superoposterior to them. (author)

  5. Computer-Assisted Instruction: Authoring Languages. ERIC Digest.

    Science.gov (United States)

    Reeves, Thomas C.

    One of the most perplexing tasks in producing computer-assisted instruction (CAI) is the authoring process. Authoring is generally defined as the process of turning the flowcharts, control algorithms, format sheets, and other documentation of a CAI program's design into computer code that will operationalize the simulation on the delivery system.…

  6. Promoting Intrinsic and Extrinsic Motivation among Chemistry Students Using Computer-Assisted Instruction

    Science.gov (United States)

    Gambari, Isiaka A.; Gbodi, Bimpe E.; Olakanmi, Eyitao U.; Abalaka, Eneojo N.

    2016-01-01

    The role of computer-assisted instruction in promoting intrinsic and extrinsic motivation among Nigerian secondary school chemistry students was investigated in this study. The study employed two modes of computer-assisted instruction (computer simulation instruction and computer tutorial instructional packages) and two levels of gender (male and…

  7. Computer-aided global breast MR image feature analysis for prediction of tumor response to chemotherapy: performance assessment

    Science.gov (United States)

    Aghaei, Faranak; Tan, Maxine; Hollingsworth, Alan B.; Zheng, Bin; Cheng, Samuel

    2016-03-01

    Dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI) has been used increasingly in breast cancer diagnosis and assessment of cancer treatment efficacy. In this study, we applied a computer-aided detection (CAD) scheme to automatically segment breast regions depicting on MR images and used the kinetic image features computed from the global breast MR images acquired before neoadjuvant chemotherapy to build a new quantitative model to predict response of the breast cancer patients to the chemotherapy. To assess performance and robustness of this new prediction model, an image dataset involving breast MR images acquired from 151 cancer patients before undergoing neoadjuvant chemotherapy was retrospectively assembled and used. Among them, 63 patients had "complete response" (CR) to chemotherapy in which the enhanced contrast levels inside the tumor volume (pre-treatment) was reduced to the level as the normal enhanced background parenchymal tissues (post-treatment), while 88 patients had "partially response" (PR) in which the high contrast enhancement remain in the tumor regions after treatment. We performed the studies to analyze the correlation among the 22 global kinetic image features and then select a set of 4 optimal features. Applying an artificial neural network trained with the fusion of these 4 kinetic image features, the prediction model yielded an area under ROC curve (AUC) of 0.83+/-0.04. This study demonstrated that by avoiding tumor segmentation, which is often difficult and unreliable, fusion of kinetic image features computed from global breast MR images without tumor segmentation can also generate a useful clinical marker in predicting efficacy of chemotherapy.

  8. Seventh Medical Image Computing and Computer Assisted Intervention Conference (MICCAI 2012)

    CERN Document Server

    Miller, Karol; Nielsen, Poul; Computational Biomechanics for Medicine : Models, Algorithms and Implementation

    2013-01-01

    One of the greatest challenges for mechanical engineers is to extend the success of computational mechanics to fields outside traditional engineering, in particular to biology, biomedical sciences, and medicine. This book is an opportunity for computational biomechanics specialists to present and exchange opinions on the opportunities of applying their techniques to computer-integrated medicine. Computational Biomechanics for Medicine: Models, Algorithms and Implementation collects the papers from the Seventh Computational Biomechanics for Medicine Workshop held in Nice in conjunction with the Medical Image Computing and Computer Assisted Intervention conference. The topics covered include: medical image analysis, image-guided surgery, surgical simulation, surgical intervention planning, disease prognosis and diagnostics, injury mechanism analysis, implant and prostheses design, and medical robotics.

  9. Maxillary arch rehabilitation using implant-supported computer-assisted design-computer-assisted manufacturing-milled titanium framework

    Directory of Open Access Journals (Sweden)

    Tulika S Khanna

    2017-01-01

    Full Text Available Esthetic and functional rehabilitation of completely edentulous maxillary arch with fixed implant supported prosthesis is a challenging task. Newer technologies such as computer assisted design computer assisted manufacturing (CAD CAM and cone beam conventional tomography play an important role in achieving predictable results. Full mouth porcelain fused to metal (PFM individual crowns on CAD CAM milled titanium framework provides positive esthetic and functional outcome. This is a case report of rehabilitation of partially edentulous maxillary arch patient. Staged rehabilitation of this patient was planned. In the first stage, root canal treatment of key abutment teeth was done, nonsalvageable teeth were removed, and immediate interim overdenture was provided. In the second stage, five Nobel Biocare dental implants were placed. After integration impressions were made, CAD CAM milled titanium bar was fabricated. Individual PFM crowns were made and cemented. This method gives better esthetic compared to acrylic fused to metal hybrid prosthesis with the advantage of retrievability just like screw retained prosthesis. Hence, this technique is good for rehabilitation of patients with high esthetic demands.

  10. Dynamic Contrast-Enhanced Computed Tomography-Derived Blood Volume and Blood Flow Correlate With Patient Outcome in Metastatic Renal Cell Carcinoma

    DEFF Research Database (Denmark)

    Mains, Jill Rachel; Donskov, Frede; Pedersen, Erik Morre

    2017-01-01

    = 7). Using a prototype software program (Advanced Perfusion and Permeability Application, Philips Healthcare, Best, the Netherlands), blood volume (BV), blood flow (BF), and permeability surface area product (PS) were calculated for each tumor at baseline, week 5, and week 10. These parameters......OBJECTIVES: The aim was to explore the potential for using dynamic contrast-enhanced computed tomography as a noninvasive functional imaging biomarker before and during the early treatment of metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS: Dynamic contrast-enhanced computed...

  11. Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dyk, Pawel; Jiang, Naomi; Sun, Baozhou; DeWees, Todd A. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Fowler, Kathryn J.; Narra, Vamsi [Department of Diagnostic Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Garcia-Ramirez, Jose L.; Schwarz, Julie K. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Grigsby, Perry W., E-mail: pgrigsby@wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Gynecologic Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Alvin J. Siteman Cancer Center, Washington University School of Medicine, St Louis, Missouri (United States)

    2014-11-15

    Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

  12. Clinical application of tumor volume in advanced nasopharyngeal carcinoma to predict outcome

    International Nuclear Information System (INIS)

    Lee, Ching-Chih; Huang, Tze-Ta; Lee, Moon-Sing; Hsiao, Shih-Hsuan; Lin, Hon-Yi; Su, Yu-Chieh; Hsu, Feng-Chun; Hung, Shih-Kai

    2010-01-01

    Current staging systems have limited ability to adjust optimal therapy in advanced nasopharyngeal carcinoma (NPC). This study aimed to delineate the correlation between tumor volume, treatment outcome and chemotherapy cycles in advanced NPC. A retrospective review of 110 patients with stage III-IV NPC was performed. All patients were treated first with neoadjuvant chemotherapy, then concurrent chemoradiation, and followed by adjuvant chemotherapy as being the definitive therapy. Gross tumor volume of primary tumor plus retropharyngeal nodes (GTVprn) was calculated to be an index of treatment outcome. GTVprn had a close relationship with survival and recurrence in advanced NPC. Large GTVprn (≧13 ml) was associated with a significantly poorer local control, lower distant metastasis-free rate, and poorer survival. In patients with GTVprn ≧ 13 ml, overall survival was better after ≧4 cycles of chemotherapy than after less than 4 cycles. The incorporation of GTVprn can provide more information to adjust treatment strategy

  13. Use of low volume in oil and air assistance in weed controlUso de baixo volume oleoso e assistência de ar no controle de plantas daninhas

    Directory of Open Access Journals (Sweden)

    Emerson da Silva Teixeira

    2010-02-01

    Full Text Available Weeds control is an important action to keep the crop production potential. The objective of this study was to evaluate the efficiency of weed control in ground spraying with and without air assistance, using conventional flow rate in herbicide application compared to low volume in oil (LVO. The experimental design was randomized with 48 m2 per plot, and five replications of five different treatments. The applications occurred in post-emergency of Digitaria insularis (L. Fedde and Commelina benghalensis L. The treatments were of conventional and LVO system, with and without air assistance, and one control. LVO applications showed similar control levels as conventional applications. The use of air assistance increased the efficiency of conventional application and reduced the efficiency of LVO applications.O controle das plantas daninhas é uma ação de grande importância para a preservação do potencial produtivo das culturas. O objetivo deste trabalho foi avaliar a eficiência do controle de plantas invasoras nas aplicações terrestres de herbicidas com e sem assistência de ar, utilizando volumes convencionais de pulverização comparados com baixo volume oleoso (BVO. O delineamento experimental empregado foi inteiramente ao acaso, com parcelas de 48 m2, com 5 tratamentos e cinco repetições. A aplicação ocorreu em pós-emergência de Digitaria insularis (L. Fedde e Commelina benghalensis L. Os tratamentos consistiram de pulverização convencional e com sistema BVO, ambos com e sem assistência de ar, mais uma testemunha. As aplicações com sistema BVO sem assistência de ar mostraram níveis de controle semelhantes às aplicações convencionais. O uso da assistência de ar elevou a eficiência das aplicações convencionais e reduziu a eficiência das aplicações em BVO.

  14. Robot-Assisted Excision of a Pararectal Gastrointestinal Stromal Tumor in a Patient with Previous Ileal Neobladder

    Directory of Open Access Journals (Sweden)

    A. Ploumidis

    2014-01-01

    Full Text Available Gastrointestinal stromal tumors (GISTs are the most frequent mesenchymal tumors of the gastrointestinal tract with surgical resection remaining the cornerstone of therapy. Pararectal lesions are considered to be technically difficult and pose in some cases a challenge. We report, to the best of our knowledge, the first robotic-assisted pararectal GIST excision. A 43-year-old man was referred to our center with pararectal GIST recurrence, despite treatment with targeted therapy. Eleven years ago, he underwent extensive abdominal surgery including cystoprostatectomy with ileal neobladder diversion due to GIST resection in the rectoprostatic space. Robot-assisted surgical resection was successfully performed without the need for temporary colostomy. The postoperative course of the patient was uneventful, and the pathology report confirmed a GIST recurrence with negative surgical margins and pelvic lymph nodes free of any tumor. Robotic-assisted pelvic surgery can be extended to incorporate excision of pararectal GISTs, as a safe, less invasive surgical alternative with promising oncological results and minimal injury to adjacent structures.

  15. 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?

    Science.gov (United States)

    Tseng, Yolanda D.; Wootton, Landon; Nyflot, Matthew; Apisarnthanarax, Smith; Rengan, Ramesh; Bloch, Charles; Sandison, George; St. James, Sara

    2018-01-01

    Four dimensional computed tomography (4DCT) scans are routinely used in radiation therapy to determine the internal treatment volume for targets that are moving (e.g. lung tumors). The use of these studies has allowed clinicians to create target volumes based upon the motion of the tumor during the imaging study. The purpose of this work is to determine if a target volume based on a single 4DCT scan at simulation is sufficient to capture thoracic motion. Phantom studies were performed to determine expected differences between volumes contoured on 4DCT scans and those on the evaluation CT scans (slow scans). Evaluation CT scans acquired during treatment of 11 patients were compared to the 4DCT scans used for treatment planning. The images were assessed to determine if the target remained within the target volume determined during the first 4DCT scan. A total of 55 slow scans were compared to the 11 planning 4DCT scans. Small differences were observed in phantom between the 4DCT volumes and the slow scan volumes, with a maximum of 2.9%, that can be attributed to minor differences in contouring and the ability of the 4DCT scan to adequately capture motion at the apex and base of the motion trajectory. Larger differences were observed in the patients studied, up to a maximum volume difference of 33.4%. These results demonstrate that a single 4DCT scan is not adequate to capture all thoracic motion throughout treatment.

  16. Preoperative classification of ovarial tumors by means of computed tomography

    International Nuclear Information System (INIS)

    Steinbrich, W.; Rohde, U.

    1982-01-01

    127 histologically demonstrated ovarial tumors were studied in a blindfold test in order to find out to what extent a preoperative determination of dignity or diagnosis of the tumor kind is possible by computed tomography. The overall rate of correct determinations of dignity is 82%. In case of functional cysts and cystomas with thin cyst walls, cystadenocarcinomas and dermoid cysts, this rate is about 95%, whereas the classification results are less exact in case of cystic tumors with broadened cyst walls, preponderantly solid tumors and tumor-like lesions. (orig.) [de

  17. Blackboard architecture and qualitative model in a computer aided assistant designed to define computers for HEP computing

    International Nuclear Information System (INIS)

    Nodarse, F.F.; Ivanov, V.G.

    1991-01-01

    Using BLACKBOARD architecture and qualitative model, an expert systm was developed to assist the use in defining the computers method for High Energy Physics computing. The COMEX system requires an IBM AT personal computer or compatible with than 640 Kb RAM and hard disk. 5 refs.; 9 figs

  18. Density overwrites of internal tumor volumes in intensity modulated proton therapy plans for mobile lung tumors

    Science.gov (United States)

    Botas, Pablo; Grassberger, Clemens; Sharp, Gregory; Paganetti, Harald

    2018-02-01

    The purpose of this study was to investigate internal tumor volume density overwrite strategies to minimize intensity modulated proton therapy (IMPT) plan degradation of mobile lung tumors. Four planning paradigms were compared for nine lung cancer patients. Internal gross tumor volume (IGTV) and internal clinical target volume (ICTV) structures were defined encompassing their respective volumes in every 4DCT phase. The paradigms use different planning CT (pCT) created from the average intensity projection (AIP) of the 4DCT, overwriting the density within the IGTV to account for movement. The density overwrites were: (a) constant filling with 100 HU (C100) or (b) 50 HU (C50), (c) maximum intensity projection (MIP) across phases, and (d) water equivalent path length (WEPL) consideration from beam’s-eye-view. Plans were created optimizing dose-influence matrices calculated with fast GPU Monte Carlo (MC) simulations in each pCT. Plans were evaluated with MC on the 4DCTs using a model of the beam delivery time structure. Dose accumulation was performed using deformable image registration. Interplay effect was addressed applying 10 times rescanning. Significantly less DVH metrics degradation occurred when using MIP and WEPL approaches. Target coverage (D99≥slant 70 Gy(RBE)) was fulfilled in most cases with MIP and WEPL (D{{99}WEPL}=69.2+/- 4.0 Gy (RBE)), keeping dose heterogeneity low (D5-D{{95}WEPL}=3.9+/- 2.0 Gy(RBE)). The mean lung dose was kept lowest by the WEPL strategy, as well as the maximum dose to organs at risk (OARs). The impact on dose levels in the heart, spinal cord and esophagus were patient specific. Overall, the WEPL strategy gives the best performance and should be preferred when using a 3D static geometry for lung cancer IMPT treatment planning. Newly available fast MC methods make it possible to handle long simulations based on 4D data sets to perform studies with high accuracy and efficiency, even prior to individual treatment planning.

  19. Interactive Computer-Assisted Instruction in Acid-Base Physiology for Mobile Computer Platforms

    Science.gov (United States)

    Longmuir, Kenneth J.

    2014-01-01

    In this project, the traditional lecture hall presentation of acid-base physiology in the first-year medical school curriculum was replaced by interactive, computer-assisted instruction designed primarily for the iPad and other mobile computer platforms. Three learning modules were developed, each with ~20 screens of information, on the subjects…

  20. Computer assisted procedure maintenance

    International Nuclear Information System (INIS)

    Bisio, R.; Hulsund, J. E.; Nilsen, S.

    2004-04-01

    The maintenance of operating procedures in a NPP is a tedious and complicated task. Through the whole life cycle of the procedures they will be dynamic, 'living' documents. Several aspects of the procedure must be considered in a revision process. Pertinent details and attributes of the procedure must be checked. An organizational structure must be created and responsibilities allotted for drafting, revising, reviewing and publishing procedures. Available powerful computer technology provides solutions within document management and computerisation of procedures. These solutions can also support the maintenance of procedures. Not all parts of the procedure life cycle are equally amenable to computerized support. This report looks at the procedure life cycle in todays NPPs and discusses the possibilities associated with introduction of computer technology to assist the maintenance of procedures. (Author)

  1. Prognostic implications of tumor volume response and COX-2 expression change during radiotherapy in cervical cancer patients

    International Nuclear Information System (INIS)

    Noh, Jae Myoung; Park, Won; Huh, Seung Jae; Cho, Eun Yoon; Choi, Yoon La; Bae, Duk Soo; Kim, Byoung Gie

    2012-01-01

    The relationship between treatment outcomes, alteration of the expression of biological markers, and tumor volume response during radiotherapy (RT) in patients with uterine cervical cancer was analyzed. Twenty patients with cervical squamous cell carcinoma received definitive RT with (n = 17) or without (n = 3) concurrent chemotherapy. Tumor volumes were measured by three serial magnetic resonance imaging scans at pre-, mid-, and post-RT. Two serial punch biopsies were performed at pre- and mid-RT, and immunohistochemical staining for cyclooxygenase (COX)-2 and epidermal growth factor receptor was performed. The median follow-up duration was 60 months. The median tumor volume response at mid-RT (V2R) was 0.396 (range, 0.136 to 0.983). At mid-RT, an interval increase in the distribution of immunoreactivity for COX-2 was observed in 8 patients, and 6 of them showed poor mid-RT tumor volume response (V2R ≥ 0.4). Four (20%) patients experienced disease progression after 10 to 12 months (median, 11 months). All 4 patients had poor mid-RT tumor volume response (p = 0.0867) and 3 of them had an interval increase in COX-2 expression. Overall survival (OS) and progression-free survival (PFS) decreased in patients with V2R ≥ 0.4 (p 0.0291 for both). An interval increase in COX-2 expression at mid-RT was also associated with a decreased survival (p = 0.1878 and 0.1845 for OS and PFS, respectively). Poor tumor volume response and an interval increase in COX-2 expression at mid-RT decreased survival outcomes in patients with uterine cervical cancer.

  2. Reduction in Tumor Volume by Cone Beam Computed Tomography Predicts Overall Survival in Non-Small Cell Lung Cancer Treated With Chemoradiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jabbour, Salma K., E-mail: jabbousk@cinj.rutgers.edu [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, Rutgers The State University of New Jersey, New Brunswick, New Jersey (United States); Kim, Sinae [Division of Biometrics, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, Rutgers The State University of New Jersey, New Brunswick, New Jersey (United States); Department of Biostatistics, School of Public Health, Rutgers University, New Brunswick, New Jersey (United States); Haider, Syed A. [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, Rutgers The State University of New Jersey, New Brunswick, New Jersey (United States); Xu, Xiaoting [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, Rutgers The State University of New Jersey, New Brunswick, New Jersey (United States); Department of Radiation Oncology, The First Affiliated Hospital of Soochow University, Soochow (China); Wu, Alson [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, Rutgers The State University of New Jersey, New Brunswick, New Jersey (United States); Surakanti, Sujani; Aisner, Joseph [Division of Medical Oncology, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, Rutgers The State University of New Jersey, New Brunswick, New Jersey (United States); Langenfeld, John [Division of Surgery, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, Rutgers The State University of New Jersey, New Brunswick, New Jersey (United States); Yue, Ning J.; Haffty, Bruce G.; Zou, Wei [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, Rutgers The State University of New Jersey, New Brunswick, New Jersey (United States)

    2015-07-01

    Purpose: We sought to evaluate whether tumor response using cone beam computed tomography (CBCT) performed as part of the routine care during chemoradiation therapy (CRT) could forecast the outcome of unresectable, locally advanced, non-small cell lung cancer (NSCLC). Methods and Materials: We manually delineated primary tumor volumes (TV) of patients with NSCLC who were treated with radical CRT on days 1, 8, 15, 22, 29, 36, and 43 on CBCTs obtained as part of the standard radiation treatment course. Percentage reductions in TV were calculated and then correlated to survival and pattern of recurrence using Cox proportional hazard models. Clinical information including histologic subtype was also considered in the study of such associations. Results: We evaluated 38 patients with a median follow-up time of 23.4 months. The median TV reduction was 39.3% (range, 7.3%-69.3%) from day 1 (D1) to day 43 (D43) CBCTs. Overall survival was associated with TV reduction from D1 to D43 (hazard ratio [HR] 0.557, 95% CI 0.39-0.79, P=.0009). For every 10% decrease in TV from D1 to D43, the risk of death decreased by 44.3%. For patients whose TV decreased ≥39.3 or <39.3%, log-rank test demonstrated a separation in survival (P=.02), with median survivals of 31 months versus 10 months, respectively. Neither local recurrence (HR 0.791, 95% CI 0.51-1.23, P=.29), nor distant recurrence (HR 0.78, 95% CI 0.57-1.08, P=.137) correlated with TV decrease from D1 to D43. Histologic subtype showed no impact on our findings. Conclusions: TV reduction as determined by CBCT during CRT as part of routine care predicts post-CRT survival. Such knowledge may justify intensification of RT or application of additional therapies. Assessment of genomic characteristics of these tumors may permit a better understanding of behavior or prediction of therapeutic outcomes.

  3. Reduction in Tumor Volume by Cone Beam Computed Tomography Predicts Overall Survival in Non-Small Cell Lung Cancer Treated With Chemoradiation Therapy

    International Nuclear Information System (INIS)

    Jabbour, Salma K.; Kim, Sinae; Haider, Syed A.; Xu, Xiaoting; Wu, Alson; Surakanti, Sujani; Aisner, Joseph; Langenfeld, John; Yue, Ning J.; Haffty, Bruce G.; Zou, Wei

    2015-01-01

    Purpose: We sought to evaluate whether tumor response using cone beam computed tomography (CBCT) performed as part of the routine care during chemoradiation therapy (CRT) could forecast the outcome of unresectable, locally advanced, non-small cell lung cancer (NSCLC). Methods and Materials: We manually delineated primary tumor volumes (TV) of patients with NSCLC who were treated with radical CRT on days 1, 8, 15, 22, 29, 36, and 43 on CBCTs obtained as part of the standard radiation treatment course. Percentage reductions in TV were calculated and then correlated to survival and pattern of recurrence using Cox proportional hazard models. Clinical information including histologic subtype was also considered in the study of such associations. Results: We evaluated 38 patients with a median follow-up time of 23.4 months. The median TV reduction was 39.3% (range, 7.3%-69.3%) from day 1 (D1) to day 43 (D43) CBCTs. Overall survival was associated with TV reduction from D1 to D43 (hazard ratio [HR] 0.557, 95% CI 0.39-0.79, P=.0009). For every 10% decrease in TV from D1 to D43, the risk of death decreased by 44.3%. For patients whose TV decreased ≥39.3 or <39.3%, log-rank test demonstrated a separation in survival (P=.02), with median survivals of 31 months versus 10 months, respectively. Neither local recurrence (HR 0.791, 95% CI 0.51-1.23, P=.29), nor distant recurrence (HR 0.78, 95% CI 0.57-1.08, P=.137) correlated with TV decrease from D1 to D43. Histologic subtype showed no impact on our findings. Conclusions: TV reduction as determined by CBCT during CRT as part of routine care predicts post-CRT survival. Such knowledge may justify intensification of RT or application of additional therapies. Assessment of genomic characteristics of these tumors may permit a better understanding of behavior or prediction of therapeutic outcomes

  4. Computed tomographic aspects of primary brain tumors in dogs and cats

    International Nuclear Information System (INIS)

    Babicsak, Viviam Rocco; Zardo, Karen Maciel; Santos, Debora Rodrigues dos; Silva, Luciana Carandina da; Machado, Vania Maria de Vasconcelos; Vulcano, Luiz Carlos

    2011-01-01

    Over the years, the Veterinary Medicine has made great advances, enabling thus the diagnosis of many diseases. As a result of this new situation, there was an increased expectation of life of animals resulting in an increase in the number of clinical care of older animals. Thus, diseases considered unusual in the past, begin to be diagnosed more frequently, as is the case of brain damage. Recently, computed tomography has been widely used in Brazil as a tool to aid in the diagnosis of several diseases. This noninvasive imaging technique allows the identification and evaluation of lesions of central nervous tissue such as brain tumors. This provides information about the size, shape and location of the lesion, in addition to the magnitude of compression and invasion of adjacent structures by the tumor and its side effects (such as the peritumoral edema and hydrocephalus). The image obtained from computed tomography may suggest the presence of a certain type brain tumor, data of great importance for the prognosis and treatment of the animal. This review covers the computed tomography aspects of primary brain tumors such as meningiomas, astrocytomas, oligodendrogliomas, choroid plexus tumors and ependymomas. However, despite the computed tomography provide much information about the changes inside the skull; no way replace histopathological examination in determining the definitive diagnosis. (author)

  5. Domain of attraction computation for tumor dynamics

    NARCIS (Netherlands)

    Doban, A.I.; Lazar, M.

    2014-01-01

    In this paper we propose the use of rational Lyapunov functions to estimate the domain of attraction of the tumor dormancy equilibrium of immune cells-malignant cells interaction dynamics. A procedure for computing rational Lyapunov functions is worked out, with focus on obtaining a meaningful

  6. (18)F-Fluorodeoxyglucose PET/Computed Tomography for Primary Brain Tumors

    DEFF Research Database (Denmark)

    Antonsen Segtnan, Eivind; Hess, Søren; Grupe, Peter

    2015-01-01

    Structural imaging with computed tomography (CT) and MR imaging is the mainstay in primary diagnosis of primary brain tumors, but these modalities depend on morphologic appearance and an intact blood-brain barrier, and important aspects of tumor biology are not addressed. Such issues may...

  7. Computer assisted functional analysis. Computer gestuetzte funktionelle Analyse

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, H A.E.; Roesler, H

    1982-01-01

    The latest developments in computer-assisted functional analysis (CFA) in nuclear medicine are presented in about 250 papers of the 19th international annual meeting of the Society of Nuclear Medicine (Bern, September 1981). Apart from the mathematical and instrumental aspects of CFA, computerized emission tomography is given particular attention. Advances in nuclear medical diagnosis in the fields of radiopharmaceuticals, cardiology, angiology, neurology, ophthalmology, pulmonology, gastroenterology, nephrology, endocrinology, oncology and osteology are discussed.

  8. Characterizing Tumor Heterogeneity With Functional Imaging and Quantifying High-Risk Tumor Volume for Early Prediction of Treatment Outcome: Cervical Cancer as a Model

    Energy Technology Data Exchange (ETDEWEB)

    Mayr, Nina A., E-mail: Nina.Mayr@osumc.edu [Department of Radiation Oncology, Ohio State University, Columbus, OH (United States); Huang Zhibin [Department of Radiation Oncology and Department of Physics, East Carolina University, Greenville, NC (United States); Wang, Jian Z. [Department of Radiation Oncology, Ohio State University, Columbus, OH (United States); Lo, Simon S. [Department of Radiation Oncology, Case Western Reserve University, Cleveland, OH (United States); Fan, Joline M. [Department of Molecular Biology, Stanford University, Stanford, CA (United States); Grecula, John C. [Department of Radiation Oncology, Ohio State University, Columbus, OH (United States); Sammet, Steffen [Department of Radiology, University of Chicago, Chicago, IL (United States); Department of Radiology, Ohio State University, Columbus, OH (United States); Sammet, Christina L. [Department of Radiology, University of Chicago, Chicago, IL (United States); Jia Guang; Zhang Jun; Knopp, Michael V.; Yuh, William T.C. [Department of Radiology, Ohio State University, Columbus, OH (United States)

    2012-07-01

    Purpose: Treatment response in cancer has been monitored by measuring anatomic tumor volume (ATV) at various times without considering the inherent functional tumor heterogeneity known to critically influence ultimate treatment outcome: primary tumor control and survival. This study applied dynamic contrast-enhanced (DCE) functional MRI to characterize tumors' heterogeneous subregions with low DCE values, at risk for treatment failure, and to quantify the functional risk volume (FRV) for personalized early prediction of treatment outcome. Methods and Materials: DCE-MRI was performed in 102 stage IB{sub 2}-IVA cervical cancer patients to assess tumor perfusion heterogeneity before and during radiation/chemotherapy. FRV represents the total volume of tumor voxels with critically low DCE signal intensity (<2.1 compared with precontrast image, determined by previous receiver operator characteristic analysis). FRVs were correlated with treatment outcome (follow-up: 0.2-9.4, mean 6.8 years) and compared with ATVs (Mann-Whitney, Kaplan-Meier, and multivariate analyses). Results: Before and during therapy at 2-2.5 and 4-5 weeks of RT, FRVs >20, >13, and >5 cm{sup 3}, respectively, significantly predicted unfavorable 6-year primary tumor control (p = 0.003, 7.3 Multiplication-Sign 10{sup -8}, 2.0 Multiplication-Sign 10{sup -8}) and disease-specific survival (p = 1.9 Multiplication-Sign 10{sup -4}, 2.1 Multiplication-Sign 10{sup -6}, 2.5 Multiplication-Sign 10{sup -7}, respectively). The FRVs were superior to the ATVs as early predictors of outcome, and the differentiating power of FRVs increased during treatment. Discussion: Our preliminary results suggest that functional tumor heterogeneity can be characterized by DCE-MRI to quantify FRV for predicting ultimate long-term treatment outcome. FRV is a novel functional imaging heterogeneity parameter, superior to ATV, and can be clinically translated for personalized early outcome prediction before or as early as 2

  9. Toward computer-assisted diagnosis and telemedicine in ophthalmology

    Czech Academy of Sciences Publication Activity Database

    Marrugo, A.; Millán, M. S.; Cristóbal, G.; Gabarda, S.; Šorel, Michal; Šroubek, Filip

    2012-01-01

    Roč. 2012, č. 6 (2012), s. 1-3 ISSN 1818-2259 R&D Projects: GA MŠk 1M0572 Institutional research plan: CEZ:AV0Z10750506 Institutional support: RVO:67985556 Keywords : computer-aided diagnosis * medical and retinal image * deconvolution * telemedicine Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2012/ZOI/sorel-toward computer-assisted diagnosis and telemedicine in ophthalmology.pdf

  10. Method of tumor volume evaluation using magnetic resonance imaging for outcome prediction in cervical cancer treated with concurrent chemotherapy and radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hun Jung; Kim, Woo Chul [Inha University Hospital, Inha University School of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    To evaluate the patterns of tumor shape and to compare tumor volume derived from simple diameter-based ellipsoid measurement with that derived from tracing the entire tumor contour using region of interest (ROI)-based 3D volumetry with respect to the prediction outcome in cervical cancer patients treated with concurrent chemotherapy and radiotherapy. Magnetic resonance imaging was performed in 98 patients with cervical cancer (stage IB-IIIB). The tumor shape was classified into two categories: ellipsoid and non-ellipsoid shape. ROI-based volumetry was derived from each magnetic resonance slice on the work station. For the diameter-based surrogate 'ellipsoid volume,' the three orthogonal diameters were measured to calculate volume as an ellipsoid. The more than half of tumor (55.1%) had a non-ellipsoid configuration. The predictions for outcome were consistent between two volume groups, with overall survival of 93.6% and 87.7% for small tumor (<20 mL), 62.9% and 69.1% for intermediate-size tumor (20-39 mL), and 14.5% and 16.7% for large tumors ({>=}40 mL) using ROI and diameter based measurement, respectively. Disease-free survival was 93.8% and 90.6% for small tumor, 54.3% and 62.7% for intermediate-size tumor, and 13.7% and 10.3% for large tumor using ROI and diameter based method, respectively. Differences in outcome between size groups were statistically significant, and the differences in outcome predicted by the tumor volume by two different methods. Our data suggested that large numbers of cervical cancers are not ellipsoid. However, simple diameter-based tumor volume measurement appears to be useful in comparison with ROI-based volumetry for predicting outcome in cervical cancer patients.

  11. Method of tumor volume evaluation using magnetic resonance imaging for outcome prediction in cervical cancer treated with concurrent chemotherapy and radiotherapy

    International Nuclear Information System (INIS)

    Kim, Hun Jung; Kim, Woo Chul

    2012-01-01

    To evaluate the patterns of tumor shape and to compare tumor volume derived from simple diameter-based ellipsoid measurement with that derived from tracing the entire tumor contour using region of interest (ROI)-based 3D volumetry with respect to the prediction outcome in cervical cancer patients treated with concurrent chemotherapy and radiotherapy. Magnetic resonance imaging was performed in 98 patients with cervical cancer (stage IB-IIIB). The tumor shape was classified into two categories: ellipsoid and non-ellipsoid shape. ROI-based volumetry was derived from each magnetic resonance slice on the work station. For the diameter-based surrogate 'ellipsoid volume,' the three orthogonal diameters were measured to calculate volume as an ellipsoid. The more than half of tumor (55.1%) had a non-ellipsoid configuration. The predictions for outcome were consistent between two volume groups, with overall survival of 93.6% and 87.7% for small tumor (<20 mL), 62.9% and 69.1% for intermediate-size tumor (20-39 mL), and 14.5% and 16.7% for large tumors (≥40 mL) using ROI and diameter based measurement, respectively. Disease-free survival was 93.8% and 90.6% for small tumor, 54.3% and 62.7% for intermediate-size tumor, and 13.7% and 10.3% for large tumor using ROI and diameter based method, respectively. Differences in outcome between size groups were statistically significant, and the differences in outcome predicted by the tumor volume by two different methods. Our data suggested that large numbers of cervical cancers are not ellipsoid. However, simple diameter-based tumor volume measurement appears to be useful in comparison with ROI-based volumetry for predicting outcome in cervical cancer patients.

  12. Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

    International Nuclear Information System (INIS)

    Nakamura, Mitsuhiro; Miyabe, Yuki; Matsuo, Yukinori; Kamomae, Takeshi; Nakata, Manabu; Yano, Shinsuke; Sawada, Akira; Mizowaki, Takashi; Hiraoka, Masahiro

    2012-01-01

    The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A 1 ) was set in the range of 0.0–12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of γ index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within ± 0.7%. From the dose area histograms on the film, the mean ± standard deviation of the dose covering 100% of the cross section of the target was 102.32 ± 1.20% (range, 100.59–103.49%). By contrast, the irradiated areas receiving more than 95% dose for A 1 = 12 mm were 1.46 and 1.33 times larger than those for A 1 = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

  13. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    Science.gov (United States)

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. [Volume changes to the neck lymph node metastases in head-neck tumors. The evaluation of radiotherapeutic treatment success].

    Science.gov (United States)

    Liszka, G; Thalacker, U; Somogyi, A; Németh, G

    1997-08-01

    This work is engaged with the volume change of neck lymph node metastasis of malignant tumors in the head-neck region during radiotherapy. In 54 patients with head and neck tumors, the volume of neck lymph nodes before and after radiation was measured. The volumetry was done with CT planimetry. The total dose was 66 Gy (2 Gy/d) telecobalt from 2 lateral opponated fields. The time of volume change could be defined with measuring of the half-time and the doubling-time by the help of Schwartz formula. After 10 Gy the volume diminution was about 20% and half-time 24 to 26 days. Afterwards the time of volume diminution picked up speed and finally achieved 60 to 72%. Meanwhile the half-time decreased to the half value. The result was independent of the site of primary tumor, the patient's sex and age. In our opinion the effectivity of radiotherapy can best be judged with defining of the volume change of lymph nodes of the neck.

  15. Computer Assisted Programmed Instruction and Cognitive ...

    African Journals Online (AJOL)

    The study probes into the effect of Computer Assisted Instruction and Cognitive preference style on achievement of secondary school Physics Students in Ogun State of Nigeria. The population of the study comprises the SS II students in Abeokuta Educational Zone. 186 students sample were drawn from the population for ...

  16. Automatic computer aided analysis algorithms and system for adrenal tumors on CT images.

    Science.gov (United States)

    Chai, Hanchao; Guo, Yi; Wang, Yuanyuan; Zhou, Guohui

    2017-12-04

    The adrenal tumor will disturb the secreting function of adrenocortical cells, leading to many diseases. Different kinds of adrenal tumors require different therapeutic schedules. In the practical diagnosis, it highly relies on the doctor's experience to judge the tumor type by reading the hundreds of CT images. This paper proposed an automatic computer aided analysis method for adrenal tumors detection and classification. It consisted of the automatic segmentation algorithms, the feature extraction and the classification algorithms. These algorithms were then integrated into a system and conducted on the graphic interface by using MATLAB Graphic user interface (GUI). The accuracy of the automatic computer aided segmentation and classification reached 90% on 436 CT images. The experiments proved the stability and reliability of this automatic computer aided analytic system.

  17. Video-Assisted Thoracoscopic Surgery in Patients With Clinically Resectable Lung Tumors

    Directory of Open Access Journals (Sweden)

    H. Sakai

    1996-01-01

    Full Text Available To investigate the feasibility of thoracoscopic resection, a pilot study was performed in patients with clinically resectable lung tumors. In 40 patients, Video-assisted thoracic surgery (VATS was performed because of suspicion of malignancy. There were 29 men and 11 women with a median age of 54.8 years (range 18 to 78. Preoperative indications were suspected lung cancer and tumor in 27 patients, assessment of tumor resectability in 7 patients, and probability of metastatic tumors in 6 patients. The final diagnoses in the 27 patients with suspected lung cancer were 12 primary lung cancers, 6 lung metastases, and 9 benign lesions. The success rates for VATS (no conversion to thoracotomy were 1 of 12 (8.3% for resectable stage I lung cancer, 8 of 12 (66.7% for metastatic tumors, and 9 of 9 (100% for benign tumors. With VATS, 6 of 7 patients (85.7%, possible stage III non-small cell lung cancer, an explorative thoracotomy with was avoided, significantly reducing morbidity. The reasons for conversion to thoracotomy were 1 oncological (N2 lymph node dissection and prevention of tumor spillage and 2 technical (inability to locate the nodule, central localization, no anatomical fissure, or poor lung function requiring full lung ventilation. The ultimate diagnoses were 19 lung cancers, 12 metastatic lung tumors, and 9 benign lung tumors. Our data show the limitations of VATS for malignant tumors in general use. These findings, together with the fact that experience in performing thoracoscopic procedures demonstrates a learning curve, may limit the use of thoracoscopic resection as a routine surgical procedure, especially when strict oncological rules are respected.

  18. The Evolution of Computer Based Learning Software Design: Computer Assisted Teaching Unit Experience.

    Science.gov (United States)

    Blandford, A. E.; Smith, P. R.

    1986-01-01

    Describes the style of design of computer simulations developed by Computer Assisted Teaching Unit at Queen Mary College with reference to user interface, input and initialization, input data vetting, effective display screen use, graphical results presentation, and need for hard copy. Procedures and problems relating to academic involvement are…

  19. Understanding PSA and its derivatives in prediction of tumor volume: Addressing health disparities in prostate cancer risk stratification.

    Science.gov (United States)

    Chinea, Felix M; Lyapichev, Kirill; Epstein, Jonathan I; Kwon, Deukwoo; Smith, Paul Taylor; Pollack, Alan; Cote, Richard J; Kryvenko, Oleksandr N

    2017-03-28

    To address health disparities in risk stratification of U.S. Hispanic/Latino men by characterizing influences of prostate weight, body mass index, and race/ethnicity on the correlation of PSA derivatives with Gleason score 6 (Grade Group 1) tumor volume in a diverse cohort. Using published PSA density and PSA mass density cutoff values, men with higher body mass indices and prostate weights were less likely to have a tumor volume PSA derivatives when predicting for tumor volume. In receiver operator characteristic analysis, area under the curve values for all PSA derivatives varied across race/ethnicity with lower optimal cutoff values for Hispanic/Latino (PSA=2.79, PSA density=0.06, PSA mass=0.37, PSA mass density=0.011) and Non-Hispanic Black (PSA=3.75, PSA density=0.07, PSA mass=0.46, PSA mass density=0.008) compared to Non-Hispanic White men (PSA=4.20, PSA density=0.11 PSA mass=0.53, PSA mass density=0.014). We retrospectively analyzed 589 patients with low-risk prostate cancer at radical prostatectomy. Pre-operative PSA, patient height, body weight, and prostate weight were used to calculate all PSA derivatives. Receiver operating characteristic curves were constructed for each PSA derivative per racial/ethnic group to establish optimal cutoff values predicting for tumor volume ≥0.5 cm3. Increasing prostate weight and body mass index negatively influence PSA derivatives for predicting tumor volume. PSA derivatives' ability to predict tumor volume varies significantly across race/ethnicity. Hispanic/Latino and Non-Hispanic Black men have lower optimal cutoff values for all PSA derivatives, which may impact risk assessment for prostate cancer.

  20. Pancreatic gross tumor volume contouring on computed tomography (CT) compared with magnetic resonance imaging (MRI): Results of an international contouring conference.

    Science.gov (United States)

    Hall, William A; Heerkens, Hanne D; Paulson, Eric S; Meijer, Gert J; Kotte, Alexis N; Knechtges, Paul; Parikh, Parag J; Bassetti, Michael F; Lee, Percy; Aitken, Katharine L; Palta, Manisha; Myrehaug, Sten; Koay, Eugene J; Portelance, Lorraine; Ben-Josef, Edgar; Erickson, Beth A

    Accurate identification of the gross tumor volume (GTV) in pancreatic adenocarcinoma is challenging. We sought to understand differences in GTV delineation using pancreatic computed tomography (CT) compared with magnetic resonance imaging (MRI). Twelve attending radiation oncologists were convened for an international contouring symposium. All participants had a clinical and research interest in pancreatic adenocarcinoma. CT and MRI scans from 3 pancreatic cases were used for contouring. CT and MRI GTVs were analyzed and compared. Interobserver variability was compared using Dice's similarity coefficient (DSC), Hausdorff distances, and Jaccard indices. Mann-Whitney tests were used to check for significant differences. Consensus contours on CT and MRI scans and constructed count maps were used to visualize the agreement. Agreement regarding the optimal method to determine GTV definition using MRI was reached. Six contour sets (3 from CT and 3 from MRI) were obtained and compared for each observer, totaling 72 contour sets. The mean volume of contours on CT was significantly larger at 57.48 mL compared with a mean of 45.76 mL on MRI, P = .011. The standard deviation obtained from the CT contours was significantly larger than the standard deviation from the MRI contours (P = .027). The mean DSC was 0.73 for the CT and 0.72 for the MRI (P = .889). The conformity index measurement was similar for CT and MRI (P = .58). Count maps were created to highlight differences in the contours from CT and MRI. Using MRI as a primary image set to define a pancreatic adenocarcinoma GTV resulted in smaller contours compared with CT. No differences in DSC or the conformity index were seen between MRI and CT. A stepwise method is recommended as an approach to contour a pancreatic GTV using MRI. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  1. Computer-assisted indexing for the INIS database

    International Nuclear Information System (INIS)

    Nevyjel, A.

    2006-01-01

    INIS has identified computer-assisted indexing as areas where information technology could assist best in maintaining database quality and indexing consistency, while containing production costs. Subject analysis is a very important but also very expensive process in the production of the INIS database. Given the current necessity to process an increased number of records, including subject analysis, without additional staff, INIS as well as the member states need improvements in their processing efficiency. Computer assisted subject analysis is a promising way to achieve this. The quality of the INIS database is defined by its inputting rules. The Thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language. It is a controlled and dynamic vocabulary of semantically and generically related terms. It is the essential tool for subject analysis as well as for advanced search engines. To support the identification of descriptors in the free text (title, abstract, free keywords) 'hidden terms' have been introduced as extension of the Thesaurus, which identify phrases or character strings of free text and point to the valid descriptor, which should be suggested. In the process of computer-assisted subject analysis the bibliographic records (including title and abstract) are analyzed by the software, resulting in a list of suggested descriptors. Within the working platform (graphical user interface) the suggested descriptors are sorted by importance (by their relevance for the content of the document) and the subject specialist clearly sees the highlighted context from which the terms were selected. The system allows the subject specialist to accept or reject descriptors from the suggested list and to assign additional descriptors when necessary. First experiences show that a performance enhancement of about 80-100% can be achieved in the subject analysis process. (author)

  2. Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions

    International Nuclear Information System (INIS)

    Das, S.K.; Miften, M.M.; Zhou, S.; Bell, M.; Munley, M.T.; Whiddon, C.S.; Craciunescu, O.; Baydush, A.H.; Wong, T.; Rosenman, J.G.; Dewhirst, M.W.; Marks, L.B.

    2004-01-01

    The information provided by functional images may be used to guide radiotherapy planning by identifying regions that require higher radiation dose. In this work we investigate the dosimetric feasibility of delivering dose to lung tumors in proportion to the fluorine-18-fluorodeoxyglucose activity distribution from positron emission tomography (FDG-PET). The rationale for delivering dose in proportion to the tumor FDG-PET activity distribution is based on studies showing that FDG uptake is correlated to tumor cell proliferation rate, which is shown to imply that this dose delivery strategy is theoretically capable of providing the same duration of local control at all voxels in tumor. Target dose delivery was constrained by single photon emission computed tomography (SPECT) maps of normal lung perfusion, which restricted irradiation of highly perfused lung and imposed dose-function constraints. Dose-volume constraints were imposed on all other critical structures. All dose-volume/function constraints were considered to be soft, i.e., critical structure doses corresponding to volume/function constraint levels were minimized while satisfying the target prescription, thus permitting critical structure doses to minimally exceed dose constraint levels. An intensity modulation optimization methodology was developed to deliver this radiation, and applied to two lung cancer patients. Dosimetric feasibility was assessed by comparing spatially normalized dose-volume histograms from the nonuniform dose prescription (FDG-PET proportional) to those from a uniform dose prescription with equivalent tumor integral dose. In both patients, the optimization was capable of delivering the nonuniform target prescription with the same ease as the uniform target prescription, despite SPECT restrictions that effectively diverted dose from high to low perfused normal lung. In one patient, both prescriptions incurred similar critical structure dosages, below dose-volume/function limits

  3. Innovative Partnerships Assist Community College Computing Programs.

    Science.gov (United States)

    O'Banion, Terry

    1987-01-01

    Relates efforts of major corporations in providing assistance to community college computing programs. Explains the goals of the League for Innovation in the Community College, a consortium of 19 community colleges, and cites examples of collaborative projects. (ML)

  4. Delineation and segmentation of cerebral tumors by mapping blood-brain barrier disruption with dynamic contrast-enhanced CT and tracer kinetics modeling-a feasibility study

    International Nuclear Information System (INIS)

    Bisdas, S.; Vogl, T.J.; Yang, X.; Koh, T.S.; Lim, C.C.T.

    2008-01-01

    Dynamic contrast-enhanced (DCE) imaging is a promising approach for in vivo assessment of tissue microcirculation. Twenty patients with clinical and routine computed tomography (CT) evidence of intracerebral neoplasm were examined with DCE-CT imaging. Using a distributed-parameter model for tracer kinetics modeling of DCE-CT data, voxel-level maps of cerebral blood flow (F), intravascular blood volume (v i ) and intravascular mean transit time (t 1 ) were generated. Permeability-surface area product (PS), extravascular extracellular blood volume (v e ) and extraction ratio (E) maps were also calculated to reveal pathologic locations of tracer extravasation, which are indicative of disruptions in the blood-brain barrier (BBB). All maps were visually assessed for quality of tumor delineation and measurement of tumor extent by two radiologists. Kappa (κ) coefficients and their 95% confidence intervals (CI) were calculated to determine the interobserver agreement for each DCE-CT map. There was a substantial agreement for the tumor delineation quality in the F, v e and t 1 maps. The agreement for the quality of the tumor delineation was excellent for the v i , PS and E maps. Concerning the measurement of tumor extent, excellent and nearly excellent agreement was achieved only for E and PS maps, respectively. According to these results, we performed a segmentation of the cerebral tumors on the base of the E maps. The interobserver agreement for the tumor extent quantification based on manual segmentation of tumor in the E maps vs. the computer-assisted segmentation was excellent (κ = 0.96, CI: 0.93-0.99). The interobserver agreement for the tumor extent quantification based on computer segmentation in the mean images and the E maps was substantial (κ = 0.52, CI: 0.42-0.59). This study illustrates the diagnostic usefulness of parametric maps associated with BBB disruption on a physiology-based approach and highlights the feasibility for automatic segmentation of

  5. Development of computer assisted learning program using cone beam projection for head radiography

    International Nuclear Information System (INIS)

    Nakazeko, Kazuma; Araki, Misao; Kajiwara, Hironori; Watanabe, Hiroyuki; Kuwayama, Jun; Karube, Shuhei; Hashimoto, Takeyuki; Shinohara, Hiroyuki

    2012-01-01

    We present a computer assisted learning (CAL) program to simulate head radiography. The program provides cone beam projections of a target volume, simulating three-dimensional computed tomography (CT) of a head phantom. The generated image is 512 x 512 x 512 pixels with each pixel 0.6 mm on a side. The imaging geometry, such as X-ray tube orientation and phantom orientation, can be varied. The graphical user interface (GUI) of the CAL program allows the study of the effects of varying the imaging geometry; each simulated projection image is shown quickly in an adjoining window. Simulated images with an assigned geometry were compared with the image obtained using the standard geometry in clinical use. The accuracy of the simulated image was verified through comparison with the image acquired using radiography of the head phantom, subsequently processed with a computed radiography system (CR image). Based on correlation coefficient analysis and visual assessment, it was concluded that the CAL program can satisfactorily simulate the CR image. Therefore, it should be useful for the training of head radiography. (author)

  6. Accurate measurement of surface areas of anatomical structures by computer-assisted triangulation of computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Allardice, J.T.; Jacomb-Hood, J.; Abulafi, A.M.; Williams, N.S. (Royal London Hospital (United Kingdom)); Cookson, J.; Dykes, E.; Holman, J. (London Hospital Medical College (United Kingdom))

    1993-05-01

    There is a need for accurate surface area measurement of internal anatomical structures in order to define light dosimetry in adjunctive intraoperative photodynamic therapy (AIOPDT). The authors investigated whether computer-assisted triangulation of serial sections generated by computed tomography (CT) scanning can give an accurate assessment of the surface area of the walls of the true pelvis after anterior resection and before colorectal anastomosis. They show that the technique of paper density tessellation is an acceptable method of measuring the surface areas of phantom objects, with a maximum error of 0.5%, and is used as the gold standard. Computer-assisted triangulation of CT images of standard geometric objects and accurately-constructed pelvic phantoms gives a surface area assessment with a maximum error of 2.5% compared with the gold standard. The CT images of 20 patients' pelves have been analysed by computer-assisted triangulation and this shows the surface area of the walls varies from 143 cm[sup 2] to 392 cm[sup 2]. (Author).

  7. 77 FR 39498 - Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection...

    Science.gov (United States)

    2012-07-03

    ...] Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection Devices Applied... Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to... guidance, entitled ``Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device...

  8. Definition of gross tumor volume in lung cancer: inter-observer variability

    NARCIS (Netherlands)

    van de Steene, Jan; Linthout, Nadine; de Mey, Johan; Vinh-Hung, Vincent; Claassens, Cornelia; Noppen, Marc; Bel, Arjan; Storme, Guy

    2002-01-01

    BACKGROUND AND PURPOSE: To determine the inter-observer variation in gross tumor volume (GTV) definition in lung cancer, and its clinical relevance. MATERIALS AND METHODS: Five clinicians involved in lung cancer were asked to define GTV on the planning CT scan of eight patients. Resulting GTVs were

  9. Computer-Assisted Instruction and Continuing Motivation.

    Science.gov (United States)

    Mosley, Mary Lou; And Others

    Effects of two feedback conditions--comment and no comment--on the motivation of sixth grade students to continue with computer assisted instruction (CAI) were investigated, and results for boys and for girls were compared. Subjects were 62 students--29 boys and 33 girls--from a suburban elementary school who were randomly assigned to the comment…

  10. Radical prostatectomy and positive surgical margins: tumor volume and Gleason score predicts cancer outcome

    International Nuclear Information System (INIS)

    La Roca, Ricardo L.R. Felts de; Fonseca, Francisco Paula da; Cunha, Isabela Werneck da; Bezerra, Stephania Martins

    2013-01-01

    Introduction: positive surgical margins (PSMs) are common adverse factors to predict the outcome of a patient submitted to radical prostatectomy (PR). However, not all of these men will follow with biochemical (BCR) or clinical (CR) recurrence. Relationship between PSMs with these recurrent events has to be correlated with other clinicopathological findings in order to recognize more aggressive tumors in order to recommend complementary treatment to these selected patients. Materials and methods: we retrospectively reviewed the outcome of 228 patients submitted to open retropubic RP between March 1991 and June 2008, where 161 had and 67 did not have PSMs. Minimum follow-up time was considered 2 years after surgery. BCR was considered when PSA ≥ 0.2 ng/ml. CR was determined when clinical evidence of tumor appeared. Chi-square test was used to correlate clinical and pathologic variables with PSMs. The estimated 5-year risk of BCR and CR in presence of PSMs was determined using the Kaplan-Meier method and compared to log-rank tests. Results: from the total of 228 patients, 161 (71%) had PSMs, while 67 (29%) had negative surgical margins (NSMs). Prostatic circumferential margin was the most common (43.4%) site. Univariate analysis showed statistically significant (p < 0.001) associations between the presence of PSMs and BCR, but not with CR (p = 0.06). Among 161 patients with PSMs, 61 (37.8%) presented BCR, while 100 (62.8%) did not. Predicting progression-free survival for 5 years, BCR was correlated with pathological stage; Gleason score; pre-treatment PSA; tumor volume in specimen; capsular and perineural invasion; presence and number of PSMs. RC correlated only with angiolymphatic invasion and Gleason score. Considering univariate analyses the clinicopathological factors predicting BCR for 5 years, results statistically significant links with prostate weight; pre-treatment PSA; Gleason score; pathological stage; tumor volume; PSMs; capsular and perineural

  11. Radical prostatectomy and positive surgical margins: tumor volume and Gleason score predicts cancer outcome

    Energy Technology Data Exchange (ETDEWEB)

    La Roca, Ricardo L.R. Felts de, E-mail: Ricardo@delarocaurologia.com.br [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil); Fonseca, Francisco Paula da, E-mail: fpf@uol.com.br [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Divisao de Urologia. Dept. de Cirurgia Pelvica; Cunha, Isabela Werneck da; Bezerra, Stephania Martins, E-mail: iwerneck@gmail.com, E-mail: stephaniab@gmail.com [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Patologia

    2013-07-01

    Introduction: positive surgical margins (PSMs) are common adverse factors to predict the outcome of a patient submitted to radical prostatectomy (PR). However, not all of these men will follow with biochemical (BCR) or clinical (CR) recurrence. Relationship between PSMs with these recurrent events has to be correlated with other clinicopathological findings in order to recognize more aggressive tumors in order to recommend complementary treatment to these selected patients. Materials and methods: we retrospectively reviewed the outcome of 228 patients submitted to open retropubic RP between March 1991 and June 2008, where 161 had and 67 did not have PSMs. Minimum follow-up time was considered 2 years after surgery. BCR was considered when PSA {>=} 0.2 ng/ml. CR was determined when clinical evidence of tumor appeared. Chi-square test was used to correlate clinical and pathologic variables with PSMs. The estimated 5-year risk of BCR and CR in presence of PSMs was determined using the Kaplan-Meier method and compared to log-rank tests. Results: from the total of 228 patients, 161 (71%) had PSMs, while 67 (29%) had negative surgical margins (NSMs). Prostatic circumferential margin was the most common (43.4%) site. Univariate analysis showed statistically significant (p < 0.001) associations between the presence of PSMs and BCR, but not with CR (p = 0.06). Among 161 patients with PSMs, 61 (37.8%) presented BCR, while 100 (62.8%) did not. Predicting progression-free survival for 5 years, BCR was correlated with pathological stage; Gleason score; pre-treatment PSA; tumor volume in specimen; capsular and perineural invasion; presence and number of PSMs. RC correlated only with angiolymphatic invasion and Gleason score. Considering univariate analyses the clinicopathological factors predicting BCR for 5 years, results statistically significant links with prostate weight; pre-treatment PSA; Gleason score; pathological stage; tumor volume; PSMs; capsular and perineural

  12. Multidetector Computed Tomography and Neuroendocrine Pancreaticoduodenal Tumors

    International Nuclear Information System (INIS)

    Rappeport, E.D.; Palnaes Hansen, C.; Kjaer, A.; Knigge, U.

    2006-01-01

    Purpose: To investigate the accuracy of dedicated pancreatic multidetector computed tomography (MDCT) in the diagnosis of neuroendocrine pancreaticoduodenal tumors (NPTs). Material and Methods: MDCT and other imaging studies in patients with suspected NPTs were identified. Thirty dedicated MDCT studies were done in 23 patients. Fourteen patients (16 operations) subsequently had surgery. Imaging reports were reviewed and findings compared with surgical findings and findings in other imaging studies. Results: Patients with surgery : 19 NPTs (16 extrapancreatic gastrinomas and 3 pancreatic NPTs) were identified at surgery. MDCT identified 16 and somatostatin receptor scintigraphy (SRS) 11 out of 19 tumors. Endoscopic ultrasound detected 11 out of 14 NPTs. Patients without surgery : In 4 out of 9 patients, no NPTs were identified at MDCT. Conclusion: Dedicated MDCT of the pancreas can identify many NPTs, including small duodenal and periduodenal tumors, and the detection rate is better than reported in the older literature on CT

  13. Computer-Assisted Periodical Routing and Renewal Audit

    Science.gov (United States)

    Yerkey, A. Neil

    1973-01-01

    A computer-assisted periodical control system was designed to reduce clerical time required to maintain records in three areas: renewal audit, routing, and records-keeping. The renewal audit features are unusual and are described in detail. (3 references) (Author/DH)

  14. Time-dependent cell disintegration kinetics in lung tumors after irradiation

    International Nuclear Information System (INIS)

    Chvetsov, Alexei V; Palta, Jatinder J; Nagata, Yasushi

    2008-01-01

    We study the time-dependent disintegration kinetics of tumor cells that did not survive radiotherapy treatment. To evaluate the cell disintegration rate after irradiation, we studied the volume changes of solitary lung tumors after stereotactic radiotherapy. The analysis is performed using two approximations: (1) tumor volume is a linear function of the total cell number in the tumor and (2) the cell disintegration rate is governed by the exponential decay with constant risk, which is defined by the initial cell number and a half-life T 1/2 . The half-life T 1/2 is determined using the least-squares fit to the clinical data on lung tumor size variation with time after stereotactic radiotherapy. We show that the tumor volume variation after stereotactic radiotherapy of solitary lung tumors can be approximated by an exponential function. A small constant component in the volume variation does not change with time; however, this component may be the residual irregular density due to radiation fibrosis and was, therefore, subtracted from the total volume variation in our computations. Using computerized fitting of the exponent function to the clinical data for selected patients, we have determined that the average half-life T 1/2 of cell disintegration is 28.2 days for squamous cell carcinoma and 72.4 days for adenocarcinoma. This model is needed for simulating the tumor volume variation during radiotherapy, which may be important for time-dependent treatment planning of proton therapy that is sensitive to density variations

  15. Definition of gross tumor volume in lung cancer: inter-observer variability

    International Nuclear Information System (INIS)

    Van de Steene, Jan; Linthout, Nadine; Mey, Johan de; Vinh-Hung, Vincent; Claassens, Cornelia; Noppen, Marc; Bel, Arjan; Storme, Guy

    2002-01-01

    Background and purpose: To determine the inter-observer variation in gross tumor volume (GTV) definition in lung cancer, and its clinical relevance. Material and methods: Five clinicians involved in lung cancer were asked to define GTV on the planning CT scan of eight patients. Resulting GTVs were compared on the base of geometric volume, dimensions and extensions. Judgement of invasion of lymph node (LN) regions was evaluated using the ATS/LCSG classification of LN. Clinical relevance of the variation was studied through 3D-dosimetry of standard conformal plans: volume of critical organs (heart, lungs, esophagus, spinal cord) irradiated at toxic doses, 95% isodose volumes of GTVs, normal tissue complication probabilities (NTCP) and tumor control probabilities (TCP) were compared for evaluation of observer variability. Results: Before evaluation of observer variability, critical review of planning CT scan led to up- (two cases) and downstaging (one case) of patients as compared to the respective diagnostic scans. The defined GTVs showed an inter-observer variation with a ratio up to more than 7 between maximum and minimum geometric content. The dimensions of the primary tumor had inter-observer ranges of 4.2 (transversal), 7.9 (cranio-caudal) and 5.4 (antero-posterior) cm. Extreme extensions of the GTVs (left, right, cranial, caudal, anterior and posterior) varied with ranges of 2.8-7.3 cm due to inter-observer variation. After common review, only 63% of involved lymph node regions were delineated by the clinicians (i.e. 37% are false negative). Twenty-two percent of drawn in lymph node regions were accepted to be false positive after review. In the conformal plans, inter-observer ranges of irradiated normal tissue volume were on average 12%, with a maximum of 66%. The probability (in the population of all conformal plans) of irradiating at least 95% of the GTV with at least 95% of the nominal treatment dose decreased from 96 to 88% when swapping the matched GTV

  16. Accuracy of computed tomography in determining pancreatic cancer tumor size

    International Nuclear Information System (INIS)

    Aoki, Kazunori; Okada, Shuichi; Moriyama, Noriyuki

    1994-01-01

    We compared tumor sizes determined by computed tomography (CT) with those of the resected specimens in 26 patients with pancreatic cancer in order to clarify whether or not the size of a pancreatic tumor can be accurately determined by CT. From the precontrast, postcontrast and arterial dominant phases of dynamic CT, the arterial dominant phase was found to yield the highest correlation between CT measured tumor size and that of the resected specimens (p<0.01). The correlation coefficient was, however, not high (r=0.67). CT alone may therefore be insufficient to determine tumor size in pancreatic cancer accurately. (author)

  17. Comparison of adrenal tumor treatment results by different volume of surgical interventions.

    Directory of Open Access Journals (Sweden)

    Dmitriy J. Semenov

    2016-10-01

    Full Text Available In recent years detection of various adrenal tumors has increased greatly. Total adrenalectomy remains the standart of surgical managment for adrenal tumors, although, the vast majority of these tumors turn out to be benign on the routine histological examination. Performing organ-sparing surgery would allow to avoid hormone insufficiency after total adrenalectomy. Aim: to compare results of adrenal tumors treatment by different volume of surgical interventions. Materials and methods. We evaluated the short-term results of 237 patients treatment with various adrenal tumors. Total adrenalectomy were performed on 206 cases, 31 patients undergone adrenal resection. There were analyzed intraoperative and postoperative complications, assessed the hormonal status of the patients, depending on the extent of surgical treatment. Besides, the long-term results were evaluated in 141 patients underwent total adrenalectomy and 30 patients after organ-sparing surgery. Moreover, we analyzed the percentage of recurrenses, assessed the hormonal status of the patients and the effectiveness of treatment. Results. Performing the organ-sparing operations doesn't increase the risk of intraoperative complications. In all patients with hormone-active tumors we found decline of pathologically increased hormone levels and trend to regress of clinical manifestations of the disease in early postoperative period. We found no difference in local recurrences in both groups, and its occurrence did not exceed 3.33%. Refractory postoperative adrenal insufficiency was observed only in corticosteroma patients in spite of surgery volume. In case of both side adrenal tumors there was no need in replacement therapy after total adrenalectomy from there one side and resection from the other. Conclusions. In cases of adrenal tumor performing organ-sparing operations is advisable, if there are no preoperative sings of malignancy.

  18. Lipiodol injections for optimization of target volume delineation in a patient with a second tumor of the oropharynx. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Haderlein, Marlen; Merten, Ricarda; Stojanovic, Andrea; Speer, Stefan; Fietkau, Rainer; Ott, Oliver J. [University Hospitals of Erlangen, Department of Radiation Oncology, Erlangen (Germany); Scherl, Claudia [University Hospitals of Erlangen, Department of Otorhinolaryngology, Erlangen (Germany)

    2015-08-15

    Lipiodol injections were administered in the head and neck area to improve gross tumor volume (GTV) definition for small-volume re-irradiation of a 63-year-old previously irradiated patient with a second tumor of the oropharynx in the posterior wall with longitudinal ligament infiltration (cT4cN0cM0). The patient had dialysis-depending renal failure. On diagnostic computed tomography (CT), which was performed with intravenous contrast agent, the tumor in the oropharynx was not detectable. Because of dialysis-depending renal failure comorbidity, no contrast agent was applied in the planning CT and in the diagnostic magnetic resonance imaging (MRI) study. In each cross-sectional imaging study performed, the GTV, especially in craniocaudal extensions, was not safely delineable. Therefore, craniocaudal tumor margins were pharyngoscopically marked with Lipiodol injections, an iodine-containing contrast agent. In a second planning CT, the GTV could be defined with the help of the Lipiodol marks and small-volume re-irradiation was performed. No Lipiodol-associated side effects occurred in the patient. In the present case, the use of Lipiodol injections at the tumor margins facilitated the definition of the GTV. (orig.) [German] Anwendung von Lipiodolinjektionen im Kopf-Hals-Bereich zur Verbesserung der GTV-Definition bei einer kleinvolumigen Re-Bestrahlung eines 63-jaehrigen, vorbestrahlten Patienten mit einem Zweitmalignom im Oropharynx mit Infiltration des hinteren Laengsbandes (cT4cN0cM0). Nebenbefundlich bestand bei dem Patienten eine dialysepflichtige Niereninsuffizienz. Im initialen diagnostischen Kontrastmittel-CT der Hals und Thoraxregion war der Tumor nicht abgrenzbar, so dass das Bestrahlungsplanungs-CT in Anbetracht des diagnostischen CTs und der bekannten Niereninsuffizienz ohne intravenoeses Kontrastmittel durchgefuehrt wurde. Das diagnostische MRT (vgl. Abb. 1) wurde ebenfalls ohne intravenoeses Kontrastmittel durchgefuehrt wurden. In allen durchgefuehrten

  19. Radiotherapy planning for glioblastoma based on a tumor growth model: improving target volume delineation

    Science.gov (United States)

    Unkelbach, Jan; Menze, Bjoern H.; Konukoglu, Ender; Dittmann, Florian; Le, Matthieu; Ayache, Nicholas; Shih, Helen A.

    2014-02-01

    Glioblastoma differ from many other tumors in the sense that they grow infiltratively into the brain tissue instead of forming a solid tumor mass with a defined boundary. Only the part of the tumor with high tumor cell density can be localized through imaging directly. In contrast, brain tissue infiltrated by tumor cells at low density appears normal on current imaging modalities. In current clinical practice, a uniform margin, typically two centimeters, is applied to account for microscopic spread of disease that is not directly assessable through imaging. The current treatment planning procedure can potentially be improved by accounting for the anisotropy of tumor growth, which arises from different factors: anatomical barriers such as the falx cerebri represent boundaries for migrating tumor cells. In addition, tumor cells primarily spread in white matter and infiltrate gray matter at lower rate. We investigate the use of a phenomenological tumor growth model for treatment planning. The model is based on the Fisher-Kolmogorov equation, which formalizes these growth characteristics and estimates the spatial distribution of tumor cells in normal appearing regions of the brain. The target volume for radiotherapy planning can be defined as an isoline of the simulated tumor cell density. This paper analyzes the model with respect to implications for target volume definition and identifies its most critical components. A retrospective study involving ten glioblastoma patients treated at our institution has been performed. To illustrate the main findings of the study, a detailed case study is presented for a glioblastoma located close to the falx. In this situation, the falx represents a boundary for migrating tumor cells, whereas the corpus callosum provides a route for the tumor to spread to the contralateral hemisphere. We further discuss the sensitivity of the model with respect to the input parameters. Correct segmentation of the brain appears to be the most

  20. Radiotherapy planning for glioblastoma based on a tumor growth model: improving target volume delineation

    International Nuclear Information System (INIS)

    Unkelbach, Jan; Dittmann, Florian; Le, Matthieu; Shih, Helen A; Menze, Bjoern H; Ayache, Nicholas; Konukoglu, Ender

    2014-01-01

    Glioblastoma differ from many other tumors in the sense that they grow infiltratively into the brain tissue instead of forming a solid tumor mass with a defined boundary. Only the part of the tumor with high tumor cell density can be localized through imaging directly. In contrast, brain tissue infiltrated by tumor cells at low density appears normal on current imaging modalities. In current clinical practice, a uniform margin, typically two centimeters, is applied to account for microscopic spread of disease that is not directly assessable through imaging. The current treatment planning procedure can potentially be improved by accounting for the anisotropy of tumor growth, which arises from different factors: anatomical barriers such as the falx cerebri represent boundaries for migrating tumor cells. In addition, tumor cells primarily spread in white matter and infiltrate gray matter at lower rate. We investigate the use of a phenomenological tumor growth model for treatment planning. The model is based on the Fisher–Kolmogorov equation, which formalizes these growth characteristics and estimates the spatial distribution of tumor cells in normal appearing regions of the brain. The target volume for radiotherapy planning can be defined as an isoline of the simulated tumor cell density. This paper analyzes the model with respect to implications for target volume definition and identifies its most critical components. A retrospective study involving ten glioblastoma patients treated at our institution has been performed. To illustrate the main findings of the study, a detailed case study is presented for a glioblastoma located close to the falx. In this situation, the falx represents a boundary for migrating tumor cells, whereas the corpus callosum provides a route for the tumor to spread to the contralateral hemisphere. We further discuss the sensitivity of the model with respect to the input parameters. Correct segmentation of the brain appears to be the most

  1. Computer-assisted learning and simulation systems in dentistry--a challenge to society.

    Science.gov (United States)

    Welk, A; Splieth, Ch; Wierinck, E; Gilpatrick, R O; Meyer, G

    2006-07-01

    Computer technology is increasingly used in practical training at universities. However, in spite of their potential, computer-assisted learning (CAL) and computer-assisted simulation (CAS) systems still appear to be underutilized in dental education. Advantages, challenges, problems, and solutions of computer-assisted learning and simulation in dentistry are discussed by means of MEDLINE, open Internet platform searches, and key results of a study among German dental schools. The advantages of computer-assisted learning are seen for example in self-paced and self-directed learning and increased motivation. It is useful for both objective theoretical and practical tests and for training students to handle complex cases. CAL can lead to more structured learning and can support training in evidence-based decision-making. The reasons for the still relatively rare implementation of CAL/CAS systems in dental education include an inability to finance, lack of studies of CAL/CAS, and too much effort required to integrate CAL/CAS systems into the curriculum. To overcome the reasons for the relative low degree of computer technology use, we should strive for multicenter research and development projects monitored by the appropriate national and international scientific societies, so that the potential of computer technology can be fully realized in graduate, postgraduate, and continuing dental education.

  2. Research on the Use of Computer-Assisted Instruction.

    Science.gov (United States)

    Craft, C. O.

    1982-01-01

    Reviews recent research studies related to computer assisted instruction (CAI). The studies concerned program effectiveness, teaching of psychomotor skills, tool availability, and factors affecting the adoption of CAI. (CT)

  3. L'Enseignement des langues assiste par ordinateur: nouvelle pedagogie? (Computer Assisted Language Instruction: New Pedagogy?).

    Science.gov (United States)

    Elkabas, Charles

    1989-01-01

    Recent second language instruction computer software focuses almost exclusively on the structures and forms of language, and on programed learning instead of developing communicative skills. Until artificial intelligence changes these old behavioristic principles, computer-assisted language instruction can only play a minor role in language…

  4. 43 Computer Assisted Programmed Instruction and Cognitive ...

    African Journals Online (AJOL)

    cce

    between Cognitive Preference Style and Computer Assisted Programmed ... teaching the subjects makes a wide range of students who have moderate numerical ability and ... on achievement of physics students, more so when such strategy has .... explaining prompting, thinking, discussing, clarifying concepts, asking ...

  5. BPACK -- A computer model package for boiler reburning/co-firing performance evaluations. User`s manual, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Wu, K.T.; Li, B.; Payne, R.

    1992-06-01

    This manual presents and describes a package of computer models uniquely developed for boiler thermal performance and emissions evaluations by the Energy and Environmental Research Corporation. The model package permits boiler heat transfer, fuels combustion, and pollutant emissions predictions related to a number of practical boiler operations such as fuel-switching, fuels co-firing, and reburning NO{sub x} reductions. The models are adaptable to most boiler/combustor designs and can handle burner fuels in solid, liquid, gaseous, and slurried forms. The models are also capable of performing predictions for combustion applications involving gaseous-fuel reburning, and co-firing of solid/gas, liquid/gas, gas/gas, slurry/gas fuels. The model package is conveniently named as BPACK (Boiler Package) and consists of six computer codes, of which three of them are main computational codes and the other three are input codes. The three main codes are: (a) a two-dimensional furnace heat-transfer and combustion code: (b) a detailed chemical-kinetics code; and (c) a boiler convective passage code. This user`s manual presents the computer model package in two volumes. Volume 1 describes in detail a number of topics which are of general users` interest, including the physical and chemical basis of the models, a complete description of the model applicability, options, input/output, and the default inputs. Volume 2 contains a detailed record of the worked examples to assist users in applying the models, and to illustrate the versatility of the codes.

  6. Errors and Intelligence in Computer-Assisted Language Learning: Parsers and Pedagogues. Routledge Studies in Computer Assisted Language Learning

    Science.gov (United States)

    Heift, Trude; Schulze, Mathias

    2012-01-01

    This book provides the first comprehensive overview of theoretical issues, historical developments and current trends in ICALL (Intelligent Computer-Assisted Language Learning). It assumes a basic familiarity with Second Language Acquisition (SLA) theory and teaching, CALL and linguistics. It is of interest to upper undergraduate and/or graduate…

  7. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Directory of Open Access Journals (Sweden)

    Shaoli Liu

    Full Text Available The "robotic-assisted liver tumor coagulation therapy" (RALTCT system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1 multiple needles are needed to destroy the entire tumor, (2 the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3 the placement of multiple needles should avoid interference with each other, (4 an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5 the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW, which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor

  8. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Science.gov (United States)

    Liu, Shaoli; Xia, Zeyang; Liu, Jianhua; Xu, Jing; Ren, He; Lu, Tong; Yang, Xiangdong

    2016-01-01

    The "robotic-assisted liver tumor coagulation therapy" (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy

  9. O padrão 4 de Gleason e o volume tumoral no prognóstico do carcinoma da próstata Well differentiated localized prostate carcinoma: prognostic relevance of tertiary Gleason pattern 4 and tumor volume

    Directory of Open Access Journals (Sweden)

    Katia R. M. Leite

    2005-12-01

    Full Text Available OBJETIVOS: A introdução de terapia adjuvante pós-prostatectomia radical foi recentemente proposta na literatura na tentativa de se obter melhores taxas de sobrevida em pacientes com câncer de próstata com maior risco de recidiva da doença. Alguns parâmetros anatomopatológicos têm sido considerados bons determinantes dos riscos de recorrência local ou à distância desses tumores. Recentemente o volume tumoral e a presença de padrão terciário de Gleason menos diferenciado foram apresentados como os melhores indicadores do comportamento do carcinoma da próstata. A proposta deste estudo é avaliar a importância da presença e porcentagem do padrão 4 de Gleason e do volume tumoral na evolução de pacientes portadores da adenocarcinoma bem diferenciado de próstata, tratados com prostatectomia radical. MÉTODOS: Setenta e sete pacientes portadores de adenocarcinoma bem diferenciado da próstata, Gleason 6 ou menos, submetidos a prostatectomia radical entre 1995 e 1997 foram estudados. Trinta e sete pacientes sofreram recidiva bioquímica (PSA > 0,4 ng/ml, e 40 pacientes permaneceram livres de doença após seguimento mínimo de cinco anos. A presença e porcentagem do padrão 4 de Gleason, a porcentagem de tumor comprometendo a glândula (considerado como "volume tumoral", a infiltração capsular e a invasão do tecido extraprostático foram submetidos a análise uni e multivariada para determinação da associação destes parâmetros com a recidiva bioquímica. RESULTADOS: O volume tumoral foi o parâmetro mais importante para determinação da recorrência bioquímica em análises uni e multivariadas. A mediana do volume foi de 25% nos pacientes que sofreram recidiva e 11,5% naqueles que permaneceram livres de doença (p=0,003. A porcentagem de padrão 4 de Gleason foi importante apenas em análise univariada. A mediana da porcentagem de Gleason 4 foi de 7,5% para os pacientes que não sofreram recidiva e de 19% naqueles que

  10. Mid-Ventilation Concept for Mobile Pulmonary Tumors: Internal Tumor Trajectory Versus Selective Reconstruction of Four-Dimensional Computed Tomography Frames Based on External Breathing Motion

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Wilbert, Juergen; Krieger, Thomas; Richter, Anne; Baier, Kurt; Flentje, Michael

    2009-01-01

    Purpose: To evaluate the accuracy of direct reconstruction of mid-ventilation and peak-phase four-dimensional (4D) computed tomography (CT) frames based on the external breathing signal. Methods and Materials: For 11 patients with 15 pulmonary targets, a respiration-correlated CT study (4D CT) was acquired for treatment planning. After retrospective time-based sorting of raw projection data and reconstruction of eight CT frames equally distributed over the breathing cycle, mean tumor position (P mean ), mid-ventilation frame, and breathing motion were evaluated based on the internal tumor trajectory. Analysis of the external breathing signal (pressure sensor around abdomen) with amplitude-based sorting of projections was performed for direct reconstruction of the mid-ventilation frame and frames at peak phases of the breathing cycle. Results: On the basis of the eight 4D CT frames equally spaced in time, tumor motion was largest in the craniocaudal direction, with 12 ± 7 mm on average. Tumor motion between the two frames reconstructed at peak phases was not different in the craniocaudal and anterior-posterior directions but was systematically smaller in the left-right direction by 1 mm on average. The 3-dimensional distance between P mean and the tumor position in the mid-ventilation frame based on the internal tumor trajectory was 1.2 ± 1 mm. Reconstruction of the mid-ventilation frame at the mean amplitude position of the external breathing signal resulted in tumor positions 2.0 ± 1.1 mm distant from P mean . Breathing-induced motion artifacts in mid-ventilation frames caused negligible changes in tumor volume and shape. Conclusions: Direct reconstruction of the mid-ventilation frame and frames at peak phases based on the external breathing signal was reliable. This makes the reconstruction of only three 4D CT frames sufficient for application of the mid-ventilation technique in clinical practice.

  11. Computer Navigation-aided Resection of Sacral Chordomas

    Directory of Open Access Journals (Sweden)

    Yong-Kun Yang

    2016-01-01

    Full Text Available Background: Resection of sacral chordomas is challenging. The anatomy is complex, and there are often no bony landmarks to guide the resection. Achieving adequate surgical margins is, therefore, difficult, and the recurrence rate is high. Use of computer navigation may allow optimal preoperative planning and improve precision in tumor resection. The purpose of this study was to evaluate the safety and feasibility of computer navigation-aided resection of sacral chordomas. Methods: Between 2007 and 2013, a total of 26 patients with sacral chordoma underwent computer navigation-aided surgery were included and followed for a minimum of 18 months. There were 21 primary cases and 5 recurrent cases, with a mean age of 55.8 years old (range: 35-84 years old. Tumors were located above the level of the S3 neural foramen in 23 patients and below the level of the S3 neural foramen in 3 patients. Three-dimensional images were reconstructed with a computed tomography-based navigation system combined with the magnetic resonance images using the navigation software. Tumors were resected via a posterior approach assisted by the computer navigation. Mean follow-up was 38.6 months (range: 18-84 months. Results: Mean operative time was 307 min. Mean intraoperative blood loss was 3065 ml. For computer navigation, the mean registration deviation during surgery was 1.7 mm. There were 18 wide resections, 4 marginal resections, and 4 intralesional resections. All patients were alive at the final follow-up, with 2 (7.7% exhibiting tumor recurrence. The other 24 patients were tumor-free. The mean Musculoskeletal Tumor Society Score was 27.3 (range: 19-30. Conclusions: Computer-assisted navigation can be safely applied to the resection of the sacral chordomas, allowing execution of preoperative plans, and achieving good oncological outcomes. Nevertheless, this needs to be accomplished by surgeons with adequate experience and skill.

  12. Computed tomography of the orbital tumors

    International Nuclear Information System (INIS)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck; Ahn, Byeong Yeob

    1987-01-01

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  13. Computed tomography of the orbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Ahn, Byeong Yeob [Han Mi Hospital, Seoul (Korea, Republic of)

    1987-04-15

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  14. Lung Tumor Radiofrequency Ablation: Where Do We Stand?

    International Nuclear Information System (INIS)

    Baère, Thierry de

    2011-01-01

    Today, radiofrequency ablation (RFA) of primary and metastatic lung tumor is increasingly used. Because RFA is most often used with curative intent, preablation workup must be a preoperative workup. General anesthesia provides higher feasibility than conscious sedation. The electrode positioning must be performed under computed tomography for sake of accuracy. The delivery of RFA must be adapted to tumor location, with different impedances used when treating tumors with or without pleural contact. The estimated rate of incomplete local treatment at 18 months was 7% (95% confidence interval, 3–14) per tumor, with incomplete treatment depicted at 4 months (n = 1), 6 months (n = 2), 9 months (n = 2), and 12 months (n = 2). Overall survival and lung disease-free survival at 18 months were, respectively, 71 and 34%. Size is a key point for tumor selection because large size is predictive of incomplete local treatment and poor survival. The ratio of ablation volume relative to tumor volume is predictive of complete ablation. Follow-up computed tomography that relies on the size of the ablation zone demonstrates the presence of incomplete ablation. Positron emission tomography might be an interesting option. Chest tube placement for pneumothorax is reported in 8 to 12%. Alveolar hemorrhage and postprocedure hemoptysis occurred in approximately 10% of procedures and rarely required specific treatment. Death was mostly related to single-lung patients and hilar tumors. No modification of forced expiratory volume in the first second between pre- and post-RFA at 2 months was found. RFA in the lung provides a high local efficacy rate. The use of RFA as a palliative tool in combination with chemotherapy remains to be explored.

  15. Assistência de ar e volumes de aplicação na deposição de calda e no controle do arroz vermelho (Oryza sativa L. Air assistance and volume of application in spray deposition and in red rice control (Oryza sativa L.

    Directory of Open Access Journals (Sweden)

    Leopoldo L. S. Vigano

    2007-12-01

    Full Text Available O trabalho teve como objetivo avaliar o efeito da assistência de ar junto à barra pulverizadora e de três volumes de pulverização na dessecação e deposição da calda em arroz vermelho, sob cultivo de nabo forrageiro, em áreas de recuperação de várzeas, utilizando o herbicida paraquat e o corante Azul Brilhante, respectivamente. Os volumes de pulverização foram 100; 200 e 300 L ha-1 da solução aquosa, contendo corante alimentício (1.500 mg L-1. Com ou sem a assistência de ar junto à barra, foram utilizadas pontas de pulverização de jato plano tipo AXI 110015 à pressão de 117,3 kPa, AXI 11002 e AXI 11003 a 276 kPa. A avaliação da deposição da pulverização deu-se em folhas de plantas de arroz vermelho. Os maiores volumes (200 e 300 L ha-1 pulverizados com a assistência de ar junto à barra pulverizadora proporcionaram maiores depósitos do corante em relação ao volume de 100 L ha-1. Não foram constatadas diferenças na deposição do corante para os volumes pulverizados, sem a assistência de ar junto à barra, tampouco entre os volumes de 200 e 300 L ha-1 com a assistência de ar junto à barra. As maiores percentagens de controle do arroz vermelho foram obtidas com a assistência de ar junto à barra, independentemente do volume pulverizado, equivalendo-se ao controle obtido com 300 L ha-1, sem o uso dessa tecnologia.The aim of this research was to evaluate the effect of air-assistance on spraying at three volumes in spray deposition and control of red rice under fodder radish cultivation. To evaluate the control of this weed and spray deposition were used paraquat herbicide and a Brilliant Blue dye, respectively. The three spraying volumes were 100, 200 and 300 L ha-1, using a tracer dye at 1,500 mg L-1. Both solutions and volumes were sprayed with flat fan nozzles AXI 110015 at 117.3 kPa, AXI 11002 and AXI 11003 at 276 kPa, respectively, with and without air-assistance on the boom. The evaluation of deposition

  16. Direct visualization of electroporation-assisted in vivo gene delivery to tumors using intravital microscopy – spatial and time dependent distribution

    International Nuclear Information System (INIS)

    Cemazar, Maja; Wilson, Ian; Dachs, Gabi U; Tozer, Gillian M; Sersa, Gregor

    2004-01-01

    Electroporation is currently receiving much attention as a way to increase drug and DNA delivery. Recent studies demonstrated the feasibility of electrogene therapy using a range of therapeutic genes for the treatment of experimental tumors. However, the transfection efficiency of electroporation-assisted DNA delivery is still low compared to viral methods and there is a clear need to optimize this approach. In order to optimize treatment, knowledge about spatial and time dependency of gene expression following delivery is of utmost importance in order to improve gene delivery. Intravital microscopy of tumors growing in dorsal skin fold window chambers is a useful method for monitoring gene transfection, since it allows non-invasive dynamic monitoring of gene expression in tumors in a live animal. Intravital microscopy was used to monitor real time spatial distribution of the green fluorescent protein (GFP) and time dependence of transfection efficiency in syngeneic P22 rat tumor model. DNA alone, liposome-DNA complexes and electroporation-assisted DNA delivery using two different sets of electric pulse parameters were compared. Electroporation-assisted DNA delivery using 8 pulses, 600 V/cm, 5 ms, 1 Hz was superior to other methods and resulted in 22% increase in fluorescence intensity in the tumors up to 6 days post-transfection, compared to the non-transfected area in granulation tissue. Functional GFP was detected within 5 h after transfection. Cells expressing GFP were detected throughout the tumor, but not in the surrounding tissue that was not exposed to electric pulses. Intravital microscopy was demonstrated to be a suitable method for monitoring time and spatial distribution of gene expression in experimental tumors and provided evidence that electroporation-assisted gene delivery using 8 pulses, 600 V/cm, 5 ms, 1 Hz is an effective method, resulting in early onset and homogenous distribution of gene expression in the syngeneic P22 rat tumor model

  17. Outcomes of Modestly Hypofractionated Radiation for Lung Tumors: Pre- and Mid-Treatment Positron Emission Tomography-Computed Tomography Metrics as Prognostic Factors.

    Science.gov (United States)

    Harris, Jeremy P; Chang-Halpenny, Christine N; Maxim, Peter G; Quon, Andrew; Graves, Edward E; Diehn, Maximilian; Loo, Billy W

    2015-11-01

    Many patients with lung tumors have tumors too large for stereotactic ablative radiotherapy and comorbidities precluding concurrent chemotherapy. We report the outcomes of 29 patients treated with hypofractionated radiotherapy (RT) to 60 to 66 Gy in 3-Gy fractions. We also report an exploratory analysis of the prognostic value of the pre- and mid-RT positron emission tomography-computed tomography. Modestly hypofractionated radiation therapy (HypoRT; 60-66 Gy in 3-Gy fractions) allows patients with locally advanced thoracic tumors and poor performance status to complete treatment within a shorter period without concurrent chemotherapy. We evaluated the outcomes and imaging prognostic factors of HypoRT. We retrospectively reviewed the data from all patients with primary and metastatic intrathoracic tumors treated with HypoRT from 2006 to 2012. We analyzed the survival and toxicity outcomes, including overall survival (OS), progression-free survival (PFS), local recurrence (LR), and distant metastasis. We also evaluated the following tumor metrics in an exploratory analysis: gross tumor volume (GTV), maximum standardized uptake value (SUVMax), and metabolic tumor volume using a threshold of ≥ 50% of the SUVMax (MTV50%) or the maximum gradient of fluorine-18 fluorodeoxyglucose uptake (MTVEdge). We assessed the association of these metrics and their changes from before to mid-RT using positron emission tomography-computed tomography (PET-CT) with OS and PFS. We identified 29 patients, all with pre-RT and 20 with mid-RT PET-CT scans. The median follow-up period was 15 months. The 2-year overall and non-small-cell lung cancer-only rate for OS, PFS, and LR, was 59% and 59%, 52% and 41%, and 27% and 32%, respectively. No grade ≥ 3 toxicities developed. The median decrease in GTV, SUVMax, and MTVEdge was 11%, 24%, and 18%, respectively. Inferior OS was associated with a larger pre-RT MTVEdge (P = .005) and pre-RT MTV50% (P = .007). Inferior PFS was associated with a

  18. Endoscope-Assisted Enucleation of Mandibular Odontogenic Keratocyst Tumors.

    Science.gov (United States)

    Romano, Antonio; Orabona, Giovanni D A; Abbate, Vincenzo; Maglitto, Fabio; Solari, Domenico; Iaconetta, Giorgio; Califano, Luigi

    2016-09-01

    The keratocyst odontogenic tumor (KCOT) represents a rare and benign but locally aggressive developmental cystic lesion usually affecting the posterior aspect of the mandible bone, the treatment of which has always been raising debate, since Philipsen first described it as a distinct pathological entity in 1956.Recent studies have proposed the use of endoscope-assisted surgical technique, due to the possibility given by the endoscope of improving the effectiveness of the treatment of these lesions thanks to a better visualization of operative field and though a better understanding of the pathology. In this article, we would like to present our experience with the endoscope-assisted treatment of KCOT of the posterior region of the mandible.From April 2000 to April 2012, 32 patients treated for KCOT were enrolled in our retrospective study: patients were divided in 2 groups according to the type of treatment, that is, 18 were treated with traditional enucleation surgery (TES), and 14 patients underwent endoscopic assisted enucleation surgery (EES).Fischer exact test and Kaplan-Meier curves were used to compare the outcomes between the 2 focusing on the recurrence and complication rates. In the TES group, patients we found a higher recurrence rate (39%) and higher postoperative complication rate at 5-year follow-up.Our data suggested, though, that EES seems to be a feasible alternative for the treatment of posterior mandibular KCOT. Further studies and larger series are needed to confirm these results.

  19. Computer Assistance for Writing Interactive Programs: TICS.

    Science.gov (United States)

    Kaplow, Roy; And Others

    1973-01-01

    Investigators developed an on-line, interactive programing system--the Teacher-Interactive Computer System (TICS)--to provide assistance to those who were not programers, but nevertheless wished to write interactive instructional programs. TICS had two components: an author system and a delivery system. Underlying assumptions were that…

  20. Estimation of error in maximal intensity projection-based internal target volume of lung tumors: a simulation and comparison study using dynamic magnetic resonance imaging.

    Science.gov (United States)

    Cai, Jing; Read, Paul W; Baisden, Joseph M; Larner, James M; Benedict, Stanley H; Sheng, Ke

    2007-11-01

    To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA) from RedCAM (epsilon), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability (nu). Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies (epsilon = -21.64% +/- 8.23%) and lung tumor patient studies (epsilon = -20.31% +/- 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly (epsilon = -5.13nu - 6.71, r(2) = 0.76) with the subjects' respiratory variability. Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.

  1. Intensity-Modulated Radiation Therapy in Oropharyngeal Carcinoma: Effect of Tumor Volume on Clinical Outcomes

    International Nuclear Information System (INIS)

    Lok, Benjamin H.; Setton, Jeremy; Caria, Nicola; Romanyshyn, Jonathan; Wolden, Suzanne L.; Zelefsky, Michael J.; Park, Jeffery; Rowan, Nicholas; Sherman, Eric J.; Fury, Matthew G.; Ho, Alan; Pfister, David G.; Wong, Richard J.; Shah, Jatin P.; Kraus, Dennis H.; Zhang, Zhigang; Schupak, Karen D.; Gelblum, Daphna Y.; Rao, Shyam D.; Lee, Nancy Y.

    2012-01-01

    Purpose: To analyze the effect of primary gross tumor volume (pGTV) and nodal gross tumor volume (nGTV) on treatment outcomes in patients treated with definitive intensity-modulated radiation therapy (IMRT) for oropharyngeal cancer (OPC). Methods and Materials: Between September 1998 and April 2009, a total of 442 patients with squamous cell carcinoma of the oropharynx were treated with IMRT with curative intent at our center. Thirty patients treated postoperatively and 2 additional patients who started treatment more than 6 months after diagnosis were excluded. A total of 340 patients with restorable treatment plans were included in this present study. The majority of the patients underwent concurrent platinum-based chemotherapy. The pGTV and nGTV were calculated using the original clinical treatment plans. Cox proportional hazards models and log-rank tests were used to evaluate the correlation between tumor volumes and overall survival (OS), and competing risks analysis tools were used to evaluate the correlation between local failure (LF), regional failure (RF), distant metastatic failure (DMF) vs. tumor volumes with death as a competing risk. Results: Median follow-up among surviving patients was 34 months (range, 5-67). The 2-year cumulative incidence of LF, RF and DF in this cohort of patients was 6.1%, 5.2%, and 12.2%, respectively. The 2-year OS rate was 88.6%. Univariate analysis determined pGTV and T-stage correlated with LF (p < 0.0001 and p = 0.004, respectively), whereas nGTV was not associated with RF. On multivariate analysis, pGTV and N-stage were independent risk factors for overall survival (p = 0.0003 and p = 0.0073, respectively) and distant control (p = 0.0008 and p = 0.002, respectively). Conclusions: In this cohort of patients with OPC treated with IMRT, pGTV was found to be associated with overall survival, local failure, and distant metastatic failure.

  2. Time-dependent cell disintegration kinetics in lung tumors after irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, Alexei V; Palta, Jatinder J [Department of Radiation Oncology, University of Florida, Gainesville, FL (United States); Nagata, Yasushi [Department of Therapeutic Radiology and Oncology, Kyoto University, Kyoto (Japan)], E-mail: chvetsov@ufl.edu

    2008-05-07

    We study the time-dependent disintegration kinetics of tumor cells that did not survive radiotherapy treatment. To evaluate the cell disintegration rate after irradiation, we studied the volume changes of solitary lung tumors after stereotactic radiotherapy. The analysis is performed using two approximations: (1) tumor volume is a linear function of the total cell number in the tumor and (2) the cell disintegration rate is governed by the exponential decay with constant risk, which is defined by the initial cell number and a half-life T{sub 1/2}. The half-life T{sub 1/2} is determined using the least-squares fit to the clinical data on lung tumor size variation with time after stereotactic radiotherapy. We show that the tumor volume variation after stereotactic radiotherapy of solitary lung tumors can be approximated by an exponential function. A small constant component in the volume variation does not change with time; however, this component may be the residual irregular density due to radiation fibrosis and was, therefore, subtracted from the total volume variation in our computations. Using computerized fitting of the exponent function to the clinical data for selected patients, we have determined that the average half-life T{sub 1/2} of cell disintegration is 28.2 days for squamous cell carcinoma and 72.4 days for adenocarcinoma. This model is needed for simulating the tumor volume variation during radiotherapy, which may be important for time-dependent treatment planning of proton therapy that is sensitive to density variations.

  3. 18F-fluorodeoxyglucose-PET/CT to evaluate tumor, nodal disease, and gross tumor volume of oropharyngeal and oral cavity cancer: comparison with MR imaging and validation with surgical specimen

    International Nuclear Information System (INIS)

    Seitz, Oliver; Chambron-Pinho, Nicole; Sader, Rober; Middendorp, Markus; Mack, Martin; Vogl, Thomas J.; Bisdas, Sotirios

    2009-01-01

    The purpose of this paper is to evaluate the impact of adding combined 18 F-PET/CT to MRI for T and N staging of the oral and oropharyngeal cancer and calculation of the gross tumor volume (GTV) having histopathology as reference standard. PET/CT and MRI were performed in 66 patients with suspected oral and oropharyngeal cancer (41 primary tumors/25 recurrent tumors) and nodal disease (114 nodes). Statistical analysis included the McNemar test, sensitivity, specificity for the diagnostic modalities as well as regression analysis, and Bland-Altman graphs for calculated tumor volumes. There was no statistically significant difference between the two modalities compared to pathological findings regarding detection of disease (P≥0.72). The sensitivity/specificity for tumor detection were 100/80% and 96.72/60% for MRI and PET/CT, respectively. The sensitivity/specificity for nodal metastases were 88.46/75% and 83.81/73.91% for MRI and PET/CT, respectively. In 18% of cases, the MRI-based T staging resulted in an overestimation of the pathologic tumor stage. The corresponding rate for PET/CT was 22%. Regarding the treated necks, both modalities showed 100% sensitivity for detection of the recurrent lesions. In necks with histologically N0 staging, MRI and PET/CT gave 22% and 26% false positive findings, respectively. The mean tumor volume in the pathologic specimen was 16.6±18.6 ml, the mean volume derived by the MR imaging was 17.6±19.1 ml while the estimated by PET/CT volume was 18.8±18.1 ml (P≤0.007 between the three methods). The Bland-Altman analysis showed a better agreement between PET/CT and MRI. The diagnostic performance of FDG-PET/CT in the local staging of oral cancer is not superior to MRI. (orig.)

  4. Mechanical Design Technology--Modified. (Computer Assisted Drafting, Computer Aided Design). Curriculum Grant 84/85.

    Science.gov (United States)

    Schoolcraft Coll., Livonia, MI.

    This document is a curriculum guide for a program in mechanical design technology (computer-assisted drafting and design developed at Schoolcraft College, Livonia, Michigan). The program helps students to acquire the skills of drafters and to interact with electronic equipment, with the option of becoming efficient in the computer-aided…

  5. [APPLICATION OF COMPUTER-ASSISTED TECHNOLOGY IN ANALYSIS OF REVISION REASON OF UNICOMPARTMENTAL KNEE ARTHROPLASTY].

    Science.gov (United States)

    Jia, Di; Li, Yanlin; Wang, Guoliang; Gao, Huanyu; Yu, Yang

    2016-01-01

    To conclude the revision reason of unicompartmental knee arthroplasty (UKA) using computer-assisted technology so as to provide reference for reducing the revision incidence and improving the level of surgical technique and rehabilitation. The relevant literature on analyzing revision reason of UKA using computer-assisted technology in recent years was extensively reviewed. The revision reasons by computer-assisted technology are fracture of the medial tibial plateau, progressive osteoarthritis of reserved compartment, dislocation of mobile bearing, prosthesis loosening, polyethylene wear, and unexplained persistent pain. Computer-assisted technology can be used to analyze the revision reason of UKA and guide the best operating method and rehabilitation scheme by simulating the operative process and knee joint activities.

  6. Pseudo tumors of the lung after lung volume reduction surgery.

    Science.gov (United States)

    Oey, Inger F; Jeyapalan, Kanagaratnam; Entwisle, James J; Waller, David A

    2004-03-01

    We describe 2 patients who underwent lung volume reduction surgery, who postoperatively had computed tomographic scans that showed symptomatic mass lesions suggestive of malignancy and an inhaled foreign body. Investigations excluded these conditions with the remaining likely diagnosis of pseudotumor secondary to buttressing material. These potential sequelae of lung volume reduction surgery should be recognized in follow-up investigations.

  7. Computer assisted diagnosis in renal nuclear medicine: rationale, methodology and interpretative criteria for diuretic renography

    Science.gov (United States)

    Taylor, Andrew T; Garcia, Ernest V

    2014-01-01

    The goal of artificial intelligence, expert systems, decision support systems and computer assisted diagnosis (CAD) in imaging is the development and implementation of software to assist in the detection and evaluation of abnormalities, to alert physicians to cognitive biases, to reduce intra and inter-observer variability and to facilitate the interpretation of studies at a faster rate and with a higher level of accuracy. These developments are needed to meet the challenges resulting from a rapid increase in the volume of diagnostic imaging studies coupled with a concurrent increase in the number and complexity of images in each patient data. The convergence of an expanding knowledge base and escalating time constraints increases the likelihood of physician errors. Errors are even more likely when physicians interpret low volume studies such as 99mTc-MAG3 diuretic scans where imagers may have had limited training or experience. Decision support systems include neural networks, case-based reasoning, expert systems and statistical systems. iRENEX (renal expert) is an expert system for diuretic renography that uses a set of rules obtained from human experts to analyze a knowledge base of both clinical parameters and quantitative parameters derived from the renogram. Initial studies have shown that the interpretations provided by iRENEX are comparable to the interpretations of a panel of experts. iRENEX provides immediate patient specific feedback at the time of scan interpretation, can be queried to provide the reasons for its conclusions and can be used as an educational tool to teach trainees to better interpret renal scans. iRENEX also has the capacity to populate a structured reporting module and generate a clear and concise impression based on the elements contained in the report; adherence to the procedural and data entry components of the structured reporting module assures and documents procedural competency. Finally, although the focus is CAD applied to

  8. Computer Assisted Language Learning (CALL) Software: Evaluation ...

    African Journals Online (AJOL)

    Evaluating the nature and extent of the influence of Computer Assisted Language Learning (CALL) on the quality of language learning is highly problematic. This is owing to the number and complexity of interacting variables involved in setting the items for teaching and learning languages. This paper identified and ...

  9. A CT-assisted method of dosimetry in brachytherapy of lung cancer

    International Nuclear Information System (INIS)

    Senan, S.; Lagerwaard, F.J.; Pan, C. de; Sipkema, D.; Murrer, L.H.P.; Burgers, S.A.

    2000-01-01

    The toxicity of endobronchial brachytherapy (EB), in particular fatal haemoptysis and bronchial wall necrosis, has been correlated with the total dose, fraction size, volume encompassed by the 100% isodose, and a proximal tumor location. We describe a CT-based planning method which, by improving target volume definition and volumeric dose information, can improve the therapeutic ratio of EB. Sixteen CT-assisted EB procedures were performed in patients who were treated with palliative high-dose rate EB. The CT data were used to analyze applicator position in relation to anatomy. An example of a three-dimensional optimized treatment plan was generated and analyzed using different types of dose-volume histograms. The procedure was well tolerated by patients and no post-procedure complications were observed. The bronchial applicator was eccentrically positioned at the level of the carina/mainstem bronchus in 12 (of 14) CT scans. A planning CT prior to EB was not found to be useful as the final target volume and/or the final applicator position were not reliably predicted before the therapeutic bronchoscopy. CT-scans performed with the applicator in situ allowed the bronchial segments in the target volume to be identified and enabled dose prescription to the bronchial mucosa. CT-assisted EB is feasible and underlines the need for using centered applicators for proximally located tumors. By enabling accurate mucosal dose prescription, CT-assisted EB may reduce the toxicity of fractionated EB in the curative setting. However, faster on-line EB treatment planning is needed for the routine clinical application of this technique. (author)

  10. Computing the partial volume of pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wiencke, Bent [Nestle USA, Corporate Engineering, 800 N. Brand Blvd, Glendale, CA 91203 (United States)

    2010-06-15

    The computation of the partial and total volume of pressure vessels with various type of head profiles requires detailed knowledge of the head profile geometry. Depending on the type of head profile the derivation of the equations can become very complex and the calculation process cumbersome. Certain head profiles require numerical methods to obtain the partial volume, which for most application is beyond the scope of practicability. This paper suggests a unique method that simplifies the calculation procedure for the various types of head profiles by using one common set of equations without the need for numerical or complex computation methods. For ease of use, all equations presented in this paper are summarized in a single table format for horizontal and vertical vessels. (author)

  11. 76 FR 71980 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... SEDASYS computer-assisted personalized sedation system (SEDASYS) submitted by Ethicon Endo-Surgery Inc...

  12. Computer Assisted Language Learning” (CALL

    Directory of Open Access Journals (Sweden)

    Nazlı Gündüz

    2005-10-01

    Full Text Available This article will provide an overview of computers; an overview of the history of CALL, itspros and cons, the internet, World Wide Web, Multimedia, and research related to the uses of computers in the language classroom. Also, it also aims to provide some background for the beginnerson using the Internet in language classes today. It discusses some of the common types of Internetactivities that are being used today, what the minimum requirements are for using the Internet forlanguage learning, and some easy activities you can adapt for your classes. Some special terminology related to computers will also be used in this paper. For example, computer assisted language learning(CALL refers to the sets of instructions which need to be loaded into the computer for it to be able to work in the language classroom. It should be borne in mind that CALL does not refer to the use of acomputer by a teacher to type out a worksheet or a class list or preparing his/her own teaching alone.Hardware refers to any computer equipment used, including the computer itself, the keyboard, screen (or the monitor, the disc-drive, and the printer. Software (computer programs refers to the sets of instructions which need to be loaded into the computer for it to be able to work.

  13. Assessment of tumor vascularization with functional computed tomography perfusion imaging in patients with cirrhotic liver disease.

    Science.gov (United States)

    Li, Jin-Ping; Zhao, De-Li; Jiang, Hui-Jie; Huang, Ya-Hua; Li, Da-Qing; Wan, Yong; Liu, Xin-Ding; Wang, Jin-E

    2011-02-01

    Hepatocellular carcinoma (HCC) is a common malignant tumor in China, and early diagnosis is critical for patient outcome. In patients with HCC, it is mostly based on liver cirrhosis, developing from benign regenerative nodules and dysplastic nodules to HCC lesions, and a better understanding of its vascular supply and the hemodynamic changes may lead to early tumor detection. Angiogenesis is essential for the growth of primary and metastatic tumors due to changes in vascular perfusion, blood volume and permeability. These hemodynamic and physiological properties can be measured serially using functional computed tomography perfusion (CTP) imaging and can be used to assess the growth of HCC. This study aimed to clarify the physiological characteristics of tumor angiogenesis in cirrhotic liver disease by this fast imaging method. CTP was performed in 30 volunteers without liver disease (control subjects) and 49 patients with liver disease (experimental subjects: 27 with HCC and 22 with cirrhosis). All subjects were also evaluated by physical examination, laboratory screening and Doppler ultrasonography of the liver. The diagnosis of HCC was made according to the EASL criteria. All patients underwent contrast-enhanced ultrasonography, pre- and post-contrast triple-phase CT and CTP study. A mathematical deconvolution model was applied to provide hepatic blood flow (HBF), hepatic blood volume (HBV), mean transit time (MTT), permeability of capillary vessel surface (PS), hepatic arterial index (HAI), hepatic arterial perfusion (HAP) and hepatic portal perfusion (HPP) data. The Mann-Whitney U test was used to determine differences in perfusion parameters between the background cirrhotic liver parenchyma and HCC and between the cirrhotic liver parenchyma with HCC and that without HCC. In normal liver, the HAP/HVP ratio was about 1/4. HCC had significantly higher HAP and HAI and lower HPP than background liver parenchyma adjacent to the HCC. The value of HBF at the tumor

  14. Computed tomographic aspects of primary brain tumors in dogs and cats; Aspectos tomograficos de tumores cerebrais primarios em caes e gatos

    Energy Technology Data Exchange (ETDEWEB)

    Babicsak, Viviam Rocco; Zardo, Karen Maciel; Santos, Debora Rodrigues dos; Silva, Luciana Carandina da; Machado, Vania Maria de Vasconcelos; Vulcano, Luiz Carlos, E-mail: viviam.babicsak@gmail.com [Setor de Diagnostico por Imagem - FMVZ - UNESP/Botucatu, SP (Brazil)

    2011-07-01

    Over the years, the Veterinary Medicine has made great advances, enabling thus the diagnosis of many diseases. As a result of this new situation, there was an increased expectation of life of animals resulting in an increase in the number of clinical care of older animals. Thus, diseases considered unusual in the past, begin to be diagnosed more frequently, as is the case of brain damage. Recently, computed tomography has been widely used in Brazil as a tool to aid in the diagnosis of several diseases. This noninvasive imaging technique allows the identification and evaluation of lesions of central nervous tissue such as brain tumors. This provides information about the size, shape and location of the lesion, in addition to the magnitude of compression and invasion of adjacent structures by the tumor and its side effects (such as the peritumoral edema and hydrocephalus). The image obtained from computed tomography may suggest the presence of a certain type brain tumor, data of great importance for the prognosis and treatment of the animal. This review covers the computed tomography aspects of primary brain tumors such as meningiomas, astrocytomas, oligodendrogliomas, choroid plexus tumors and ependymomas. However, despite the computed tomography provide much information about the changes inside the skull; no way replace histopathological examination in determining the definitive diagnosis. (author)

  15. [Computer aided diagnosis model for lung tumor based on ensemble convolutional neural network].

    Science.gov (United States)

    Wang, Yuanyuan; Zhou, Tao; Lu, Huiling; Wu, Cuiying; Yang, Pengfei

    2017-08-01

    The convolutional neural network (CNN) could be used on computer-aided diagnosis of lung tumor with positron emission tomography (PET)/computed tomography (CT), which can provide accurate quantitative analysis to compensate for visual inertia and defects in gray-scale sensitivity, and help doctors diagnose accurately. Firstly, parameter migration method is used to build three CNNs (CT-CNN, PET-CNN, and PET/CT-CNN) for lung tumor recognition in CT, PET, and PET/CT image, respectively. Then, we aimed at CT-CNN to obtain the appropriate model parameters for CNN training through analysis the influence of model parameters such as epochs, batchsize and image scale on recognition rate and training time. Finally, three single CNNs are used to construct ensemble CNN, and then lung tumor PET/CT recognition was completed through relative majority vote method and the performance between ensemble CNN and single CNN was compared. The experiment results show that the ensemble CNN is better than single CNN on computer-aided diagnosis of lung tumor.

  16. Mathematical and Computational Modeling for Tumor Virotherapy with Mediated Immunity.

    Science.gov (United States)

    Timalsina, Asim; Tian, Jianjun Paul; Wang, Jin

    2017-08-01

    We propose a new mathematical modeling framework based on partial differential equations to study tumor virotherapy with mediated immunity. The model incorporates both innate and adaptive immune responses and represents the complex interaction among tumor cells, oncolytic viruses, and immune systems on a domain with a moving boundary. Using carefully designed computational methods, we conduct extensive numerical simulation to the model. The results allow us to examine tumor development under a wide range of settings and provide insight into several important aspects of the virotherapy, including the dependence of the efficacy on a few key parameters and the delay in the adaptive immunity. Our findings also suggest possible ways to improve the virotherapy for tumor treatment.

  17. Comparison of Computed Tomography– and Magnetic Resonance Imaging–based Clinical Target Volume Contours at Brachytherapy for Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Swanick, Cameron W. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Castle, Katherine O. [Southeast Louisiana Radiation Oncology Group, Baton Rouge, Louisiana (United States); Vedam, Sastry [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Munsell, Mark F. [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Turner, Lehendrick M. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rauch, Gaiane M. [Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Jhingran, Anuja; Eifel, Patricia J. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Klopp, Ann H., E-mail: aklopp@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2016-11-15

    Purpose: We prospectively compared computed tomography (CT)– and magnetic resonance imaging (MRI)–based high-risk clinical target volume (HR-CTV) contours at the time of brachytherapy for cervical cancer in an effort to identify patients who might benefit most from MRI-based planning. Methods and Materials: Thirty-seven patients who had undergone a pretreatment diagnostic MRI scan were included in the analysis. We delineated the HR-CTV on the brachytherapy CT and brachytherapy MRI scans independently for each patient. We then calculated the absolute volumes for each HR-CTV and the Dice coefficient of similarity (DC, a measure of spatial agreement) for the HR-CTV contours. We identified the clinical and tumor factors associated with (1) a discrepancy in volume between the CT HR-CTV and MRI HR-CTV contours; and (2) DC. The mean values were compared using 1-way analysis of variance or paired or unpaired t tests, as appropriate. Simple and multivariable linear regression analyses were used to model the effects of covariates on the outcomes. Results: Patients with International Federation of Gynecology and Obstetrics stage IB to IVA cervical cancer were treated with intracavitary brachytherapy using tandem and ovoid (n=33) or tandem and cylinder (n=4) applicators. The mean CT HR-CTV volume (44.1 cm{sup 3}) was larger than the mean MRI HR-CTV volume (35.1 cm{sup 3}; P<.0001, paired t test). On multivariable analysis, a higher body mass index (BMI) and tumor size ≥5 cm with parametrial invasion on the MRI scan at diagnosis were associated with an increased discrepancy in volume between the HR-CTV contours (P<.02 for both). In addition, the spatial agreement (as measured by DC) between the HR-CTV contours decreased with an increasing BMI (P=.013). Conclusions: We recommend MRI-based brachytherapy planning for patients with tumors >5 cm and parametrial invasion on MRI at diagnosis and for those with a high BMI.

  18. SPAM-assisted partial volume correction algorithm for PET

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2000-07-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38{+-}6%, while those of hippocampus and amygdala by 4{+-}3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images.

  19. SPAM-assisted partial volume correction algorithm for PET

    International Nuclear Information System (INIS)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul

    2000-01-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38±6%, while those of hippocampus and amygdala by 4±3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images

  20. Dose-volume considerations in stereotaxic brain radiation therapy

    International Nuclear Information System (INIS)

    Houdek, P.V.; Schwade, J.G.; Pisciotta, V.J.; Medina, A.J.; Lewin, A.A.; Abitbol, A.A.; Serago, C.F.

    1988-01-01

    Although brain radiation therapy experience suggests that a gain in the therapeutic ratio may be achieved by optimizing the dose-volume relationship, no practical system for quantitative assessment of dose-volume data has been developed. This presentation describes the rationale for using the integral dose function for this purpose and demonstrates that with the use of a conventional treatment planning computer and a series of computed tomographic scans, first-order optimization of the dose-volume function can be accomplished in two steps: first, high-dose volume is minimized by selecting an appropriate treatment technique and tumor margin, and then dosage is maximized by calculating the brain tolerance dose as a function of the irradiated volume

  1. Tumor Volume Reduction Rate Measured by Magnetic Resonance Volumetry Correlated With Pathologic Tumor Response of Preoperative Chemoradiotherapy for Rectal Cancer

    International Nuclear Information System (INIS)

    Yeo, Seung-Gu; Kim, Dae Yong; Kim, Tae Hyun; Jung, Kyung Hae; Hong, Yong Sang; Chang, Hee Jin; Park, Ji Won; Lim, Seok-Byung; Choi, Hyo Seong; Jeong, Seung-Yong

    2010-01-01

    Purpose: To determine whether the tumor volume reduction rate (TVRR) measured using three-dimensional region-of-interest magnetic resonance volumetry correlates with the pathologic tumor response after preoperative chemoradiotherapy (CRT) for locally advanced rectal cancer. Methods and Materials: The study included 405 patients with locally advanced rectal cancer (cT3-T4) who had undergone preoperative CRT and radical proctectomy. The tumor volume was measured using three-dimensional region-of-interest magnetic resonance volumetry before and after CRT but before surgery. We analyzed the correlation between the TVRR and the pathologic tumor response in terms of downstaging and tumor regression grade (TRG). Downstaging was defined as ypStage 0-I (ypT0-T2N0M0), and the TRG proposed by Dworak et al. was used. Results: The mean TVRR was 65.0% ± 22.3%. Downstaging and complete regression occurred in 167 (41.2%) and 58 (14.3%) patients, respectively. The TVRRs according to ypT classification (ypT0-T2 vs. ypT3-T4), ypN classification (ypN0 vs. ypN1-N2), downstaging (ypStage 0-I vs. ypStage II-III), good regression (TRG 3-4 vs. TRG 1-2), and complete regression (TRG 4 vs. TRG 1-3) were all significantly different (p 80%), the rates of ypT0-T2, ypN0, downstaging, and good regression were all significantly greater for patients with a TVRR of ≥60%, as was the complete regression rate for patients with a TVRR >80% (p <.05). Conclusion: The TVRR measured using three-dimensional region-of-interest magnetic resonance volumetry correlated significantly with the pathologic tumor response in terms of downstaging and TRG after preoperative CRT for locally advanced rectal cancer.

  2. Obtention of tumor volumes in PET images stacks using techniques of colored image segmentation; Obtencao de volumes tumorais em pilhas de imagens PET usando tecnicas de segmentacao de imagens coloridas

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Jose W.; Lopes Filho, Ferdinand J., E-mail: jose.wilson@recife.ifpe.edu.br [Instituto Federal de Educacao e Tecnologia de Pernambuco (IFPE) Recife, PE (Brazil); Vieira, Igor F., E-mail: igoradiologia@gmail.com [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Lima, Fernando R.A.; Cordeiro, Landerson P., E-mail: leoxofisico@gmail.com, E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-NE), Recife, PE (Brazil)

    2014-07-01

    This work demonstrated step by step how to segment color images of the chest of an adult in order to separate the tumor volume without significantly changing the values of the components R (Red), G (Green) and B (blue) of the colors of the pixels. For having information which allow to build color map you need to segment and classify the colors present at appropriate intervals in images. The used segmentation technique is to select a small rectangle with color samples in a given region and then erase with a specific color called 'rubber' the other regions of image. The tumor region was segmented into one of the images available and the procedure is displayed in tutorial format. All necessary computational tools have been implemented in DIP (Digital Image Processing), software developed by the authors. The results obtained, in addition to permitting the construction the colorful map of the distribution of the concentration of activity in PET images will also be useful in future work to enter tumors in voxel phantoms in order to perform dosimetric assessments.

  3. Conversation Analysis in Computer-Assisted Language Learning

    Science.gov (United States)

    González-Lloret, Marta

    2015-01-01

    The use of Conversation Analysis (CA) in the study of technology-mediated interactions is a recent methodological addition to qualitative research in the field of Computer-assisted Language Learning (CALL). The expansion of CA in Second Language Acquisition research, coupled with the need for qualitative techniques to explore how people interact…

  4. Measurement of liver volume by emission computed tomography

    International Nuclear Information System (INIS)

    Kan, M.K.; Hopkins, G.B.

    1979-01-01

    In 22 volunteers without clinical or laboratory evidence of liver disease, liver volume was determined using single-photon emission computed tomography (ECT). This technique provided excellent object contrast between the liver and its surroundings and permitted calculation of liver volume without geometric assumptions about the liver's configuration. Reproducibility of results was satisfactory, with a root-mean-square error of less than 6% between duplicate measurements in 15 individuals. The volume measurements were validated by the use of phantoms

  5. Using computer assisted learning for clinical skills education in nursing: integrative review.

    Science.gov (United States)

    Bloomfield, Jacqueline G; While, Alison E; Roberts, Julia D

    2008-08-01

    This paper is a report of an integrative review of research investigating computer assisted learning for clinical skills education in nursing, the ways in which it has been studied and the general findings. Clinical skills are an essential aspect of nursing practice and there is international debate about the most effective ways in which these can be taught. Computer assisted learning has been used as an alternative to conventional teaching methods, and robust research to evaluate its effectiveness is essential. The CINAHL, Medline, BNI, PsycInfo and ERIC electronic databases were searched for the period 1997-2006 for research-based papers published in English. Electronic citation tracking and hand searching of reference lists and relevant journals was also undertaken. Twelve studies met the inclusion criteria. An integrative review was conducted and each paper was explored in relation to: design, aims, sample, outcome measures and findings. Many of the study samples were small and there were weaknesses in designs. There is limited empirical evidence addressing the use of computer assisted learning for clinical skills education in nursing. Computer assisted learning has been used to teach a limited range of clinical skills in a variety of settings. The paucity of evaluative studies indicates the need for more rigorous research to investigate the effect of computer assisted learning for this purpose. Areas that need to be addressed in future studies include: sample size, range of skills, longitudinal follow-up and control of confounding variables.

  6. Multivariate Feature Selection of Image Descriptors Data for Breast Cancer with Computer-Assisted Diagnosis

    Directory of Open Access Journals (Sweden)

    Carlos E. Galván-Tejada

    2017-02-01

    Full Text Available Breast cancer is an important global health problem, and the most common type of cancer among women. Late diagnosis significantly decreases the survival rate of the patient; however, using mammography for early detection has been demonstrated to be a very important tool increasing the survival rate. The purpose of this paper is to obtain a multivariate model to classify benign and malignant tumor lesions using a computer-assisted diagnosis with a genetic algorithm in training and test datasets from mammography image features. A multivariate search was conducted to obtain predictive models with different approaches, in order to compare and validate results. The multivariate models were constructed using: Random Forest, Nearest centroid, and K-Nearest Neighbor (K-NN strategies as cost function in a genetic algorithm applied to the features in the BCDR public databases. Results suggest that the two texture descriptor features obtained in the multivariate model have a similar or better prediction capability to classify the data outcome compared with the multivariate model composed of all the features, according to their fitness value. This model can help to reduce the workload of radiologists and present a second opinion in the classification of tumor lesions.

  7. Multivariate Feature Selection of Image Descriptors Data for Breast Cancer with Computer-Assisted Diagnosis.

    Science.gov (United States)

    Galván-Tejada, Carlos E; Zanella-Calzada, Laura A; Galván-Tejada, Jorge I; Celaya-Padilla, José M; Gamboa-Rosales, Hamurabi; Garza-Veloz, Idalia; Martinez-Fierro, Margarita L

    2017-02-14

    Breast cancer is an important global health problem, and the most common type of cancer among women. Late diagnosis significantly decreases the survival rate of the patient; however, using mammography for early detection has been demonstrated to be a very important tool increasing the survival rate. The purpose of this paper is to obtain a multivariate model to classify benign and malignant tumor lesions using a computer-assisted diagnosis with a genetic algorithm in training and test datasets from mammography image features. A multivariate search was conducted to obtain predictive models with different approaches, in order to compare and validate results. The multivariate models were constructed using: Random Forest, Nearest centroid, and K-Nearest Neighbor (K-NN) strategies as cost function in a genetic algorithm applied to the features in the BCDR public databases. Results suggest that the two texture descriptor features obtained in the multivariate model have a similar or better prediction capability to classify the data outcome compared with the multivariate model composed of all the features, according to their fitness value. This model can help to reduce the workload of radiologists and present a second opinion in the classification of tumor lesions.

  8. Experimental rat lung tumor model with intrabronchial tumor cell implantation.

    Science.gov (United States)

    Gomes Neto, Antero; Simão, Antônio Felipe Leite; Miranda, Samuel de Paula; Mourão, Lívia Talita Cajaseiras; Bezerra, Nilfácio Prado; Almeida, Paulo Roberto Carvalho de; Ribeiro, Ronaldo de Albuquerque

    2008-01-01

    The objective of this study was to develop a rat lung tumor model for anticancer drug testing. Sixty-two female Wistar rats weighing 208 +/- 20 g were anesthetized intraperitoneally with 2.5% tribromoethanol (1 ml/100 g live weight), tracheotomized and intubated with an ultrafine catheter for inoculation with Walker's tumor cells. In the first step of the experiment, a technique was established for intrabronchial implantation of 10(5) to 5 x 10(5) tumor cells, and the tumor take rate was determined. The second stage consisted of determining tumor volume, correlating findings from high-resolution computed tomography (HRCT) with findings from necropsia and determining time of survival. The tumor take rate was 94.7% for implants with 4 x 10(5) tumor cells, HRCT and necropsia findings matched closely (r=0.953; p<0.0001), the median time of survival was 11 days, and surgical mortality was 4.8%. The present rat lung tumor model was shown to be feasible: the take rate was high, surgical mortality was negligible and the procedure was simple to perform and easily reproduced. HRCT was found to be a highly accurate tool for tumor diagnosis, localization and measurement and may be recommended for monitoring tumor growth in this model.

  9. Computing volume potentials for noninvasive imaging of cardiac excitation.

    Science.gov (United States)

    van der Graaf, A W Maurits; Bhagirath, Pranav; van Driel, Vincent J H M; Ramanna, Hemanth; de Hooge, Jacques; de Groot, Natasja M S; Götte, Marco J W

    2015-03-01

    In noninvasive imaging of cardiac excitation, the use of body surface potentials (BSP) rather than body volume potentials (BVP) has been favored due to enhanced computational efficiency and reduced modeling effort. Nowadays, increased computational power and the availability of open source software enable the calculation of BVP for clinical purposes. In order to illustrate the possible advantages of this approach, the explanatory power of BVP is investigated using a rectangular tank filled with an electrolytic conductor and a patient specific three dimensional model. MRI images of the tank and of a patient were obtained in three orthogonal directions using a turbo spin echo MRI sequence. MRI images were segmented in three dimensional using custom written software. Gmsh software was used for mesh generation. BVP were computed using a transfer matrix and FEniCS software. The solution for 240,000 nodes, corresponding to a resolution of 5 mm throughout the thorax volume, was computed in 3 minutes. The tank experiment revealed that an increased electrode surface renders the position of the 4 V equipotential plane insensitive to mesh cell size and reduces simulated deviations. In the patient-specific model, the impact of assigning a different conductivity to lung tissue on the distribution of volume potentials could be visualized. Generation of high quality volume meshes and computation of BVP with a resolution of 5 mm is feasible using generally available software and hardware. Estimation of BVP may lead to an improved understanding of the genesis of BSP and sources of local inaccuracies. © 2014 Wiley Periodicals, Inc.

  10. SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Y; Aileen, C; Kozono, D; Killoran, J; Wagar, M; Lee, S; Hacker, F; Aerts, H; Lewis, J; Mak, R [Brigham and Women’s Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after the same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye

  11. SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

    International Nuclear Information System (INIS)

    Hou, Y; Aileen, C; Kozono, D; Killoran, J; Wagar, M; Lee, S; Hacker, F; Aerts, H; Lewis, J; Mak, R

    2015-01-01

    Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after the same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye

  12. Computer-Assisted Language Learning: Diversity in Research and Practice

    Science.gov (United States)

    Stockwell, Glenn, Ed.

    2012-01-01

    Computer-assisted language learning (CALL) is an approach to teaching and learning languages that uses computers and other technologies to present, reinforce, and assess material to be learned, or to create environments where teachers and learners can interact with one another and the outside world. This book provides a much-needed overview of the…

  13. The influence of quantitative tumor volume measurements on local control in advanced head and neck cancer using concomitant boost accelerated superfractionated irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Christopher R; Khandelwal, Shiv R; Schmidt-Ullrich, Rupert K; Ravalese, Joseph; Wazer, David E

    1995-06-15

    Purpose: Current methods to clinically define head and neck tumor bulk are qualitative and imprecise. Although the American Joint Committee on Cancer (AJCC) staging system is important for this purpose, limitations exist. This study will investigate the prognostic value of computed tomography (CT) derived tumor volume measurements in comparison to AJCC stage and other significant variables. Materials and Methods: Seventy-six patients with advanced head and neck squamous cell carcinoma were treated with concomitant boost accelerated superfractionated irradiation. Doses ranged from 68.4-73.8 Gy (median 70.2 Gy). Good quality pretherapy CT scans were available in 51 patients. Total tumor volume (TTV) estimates were derived from these scans using digital integration of primary tumor and metastatic lymphadenopathy. Actuarial and multivariate statistical techniques were applied to analyze local control. Results: Thirty-six-month local control was 63%. TTV ranged from 5-196 cm{sup 3} (median 35 cm{sup 3}) for all cases, 5-142 cm{sup 3} (median 17 cm{sup 3}) for those controlled, and 16-196 cm{sup 3} (median 47 cm{sup 3}) for local failures. There was a significant increase in failures above 35 cm{sup 3}. Univariate analysis found that TTV, T-stage, N-stage, and primary site were each significant prognostic variables. Local control for TTV {<=}35 cm{sup 3} was 92% at 36 months vs. 34% for TTV >35 cm{sup 3} (p = 0.0001). Multivariate analysis, however, found that TTV, primary site, and sex were important as independent variables; T and N stage were not independently significant unless TTV was removed from the model. Conclusions: This study demonstrates the prognostic significance of TTV in advanced carcinoma of the head and neck. This variable appears to be a more predictive than AJCC clinical stage. Quantitative tumor volume measurements may prove to be a useful parameter in future analyses of head and neck cancer.

  14. {sup 18}F-fluorodeoxyglucose-PET/CT to evaluate tumor, nodal disease, and gross tumor volume of oropharyngeal and oral cavity cancer: comparison with MR imaging and validation with surgical specimen

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, Oliver; Chambron-Pinho, Nicole; Sader, Rober [JW Goethe University, Department of Oromaxillofacial Surgery, Frankfurt (Germany); Middendorp, Markus [JW Goethe University, Department of Nuclear Medicine, Frankfurt (Germany); Mack, Martin; Vogl, Thomas J. [JW Goethe University, Department of Radiology, Frankfurt (Germany); Bisdas, Sotirios [Eberhard Karls University, Department of Neuroradiology, Tuebingen (Germany)

    2009-10-15

    The purpose of this paper is to evaluate the impact of adding combined {sup 18}F-PET/CT to MRI for T and N staging of the oral and oropharyngeal cancer and calculation of the gross tumor volume (GTV) having histopathology as reference standard. PET/CT and MRI were performed in 66 patients with suspected oral and oropharyngeal cancer (41 primary tumors/25 recurrent tumors) and nodal disease (114 nodes). Statistical analysis included the McNemar test, sensitivity, specificity for the diagnostic modalities as well as regression analysis, and Bland-Altman graphs for calculated tumor volumes. There was no statistically significant difference between the two modalities compared to pathological findings regarding detection of disease (P{>=}0.72). The sensitivity/specificity for tumor detection were 100/80% and 96.72/60% for MRI and PET/CT, respectively. The sensitivity/specificity for nodal metastases were 88.46/75% and 83.81/73.91% for MRI and PET/CT, respectively. In 18% of cases, the MRI-based T staging resulted in an overestimation of the pathologic tumor stage. The corresponding rate for PET/CT was 22%. Regarding the treated necks, both modalities showed 100% sensitivity for detection of the recurrent lesions. In necks with histologically N0 staging, MRI and PET/CT gave 22% and 26% false positive findings, respectively. The mean tumor volume in the pathologic specimen was 16.6{+-}18.6 ml, the mean volume derived by the MR imaging was 17.6{+-}19.1 ml while the estimated by PET/CT volume was 18.8{+-}18.1 ml (P{<=}0.007 between the three methods). The Bland-Altman analysis showed a better agreement between PET/CT and MRI. The diagnostic performance of FDG-PET/CT in the local staging of oral cancer is not superior to MRI. (orig.)

  15. Role of computed tomography in the integral diagnostic process of paranasal cavities tumors

    International Nuclear Information System (INIS)

    Lazarova, I.

    1990-01-01

    Results are reported of computed tomographic examination of 129 patients from 3 to 74 years of age, on clinical grounds suspected of having, or histologically verified, tumors of the paranasal cavities. Axial and/or coronary scanning (depending on the case) was performed on computed tomograph Tomoscan-310, according to previously selected programs. Computed tomography was evaluated with regard to the possibility for diagnosing tumors of the paranasal sinuses and its role in furnishing additional information in these diseases. The clearcut differentiation on the computed tomograms both of the bone structures and of the soft tissue - muscles, vessels, connective tissue and fatty tissue spaces - is emphasized. The clinical significance of this special X-ray method of examination in the preoperative period by demonstrating the different directions in which the tumors spread and the possibility for adequate planning of the radiotherapeutic field and posttherapeutic follow-up the pathologic process are pointed out. 5 figs., 5 refs

  16. Measurement of mesothelioma on thoracic CT scans: A comparison of manual and computer-assisted techniques

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Oxnard, Geoffrey R.; MacMahon, Heber; Vogelzang, Nicholas J.; Kindler, Hedy L.; Kocherginsky, Masha; Starkey, Adam

    2004-01-01

    Our purpose in this study was to evaluate the variability of manual mesothelioma tumor thickness measurements in computed tomography (CT) scans and to assess the relative performance of six computerized measurement algorithms. The CT scans of 22 patients with malignant pleural mesothelioma were collected. In each scan, an initial observer identified up to three sites in each of three CT sections at which tumor thickness measurements were to be made. At each site, five observers manually measured tumor thickness through a computer interface. Three observers repeated these measurements during three separate sessions. Inter- and intra-observer variability in the manual measurement of tumor thickness was assessed. Six automated measurement algorithms were developed based on the geometric relationship between a specified measurement site and the automatically extracted lung regions. Computer-generated measurements were compared with manual measurements. The tumor thickness measurements of different observers were highly correlated (r≥0.99); however, the 95% limits of agreement for relative inter-observer difference spanned a range of 30%. Tumor thickness measurements generated by the computer algorithms also correlated highly with the average of observer measurements (r≥0.93). We have developed computerized techniques for the measurement of mesothelioma tumor thickness in CT scans. These techniques achieved varying levels of agreement with measurements made by human observers

  17. OncoTREAT: a software assistant for cancer therapy monitoring

    International Nuclear Information System (INIS)

    Bornemann, Lars; Dicken, Volker; Kuhnigk, Jan-Martin; Krass, Stefan; Peitgen, Heinz-Otto; Wormanns, Dag; Shin, Hoen-Oh; Bauknecht, Hans-Christian; Diehl, Volker; Fabel, Michael; Meier, Stefan; Kress, Oliver

    2007-01-01

    ObjectCancer is one of the leading causes of death worldwide and therapy options are often associated with severe stress for the patient and high costs. Therefore, precise evaluation of therapy success is essential. Material and Methods In the framework of the VICORA research project (Virtual Institute for Computer Assistance in Clinical Radiology), a software application was developed to support the radiologist in evaluating the response to tumor therapy. The application provides follow-up support for oncological therapy monitoring by volumetric quantification of lung, liver and brain metastases as well as enlarged lymph nodes and assists the user by temporal registration of lesion positions. Results With close cooperation between computer scientists and radiologists the application was tested and optimized to achieve a high degree of usability. Several clinical studies were carried out to evaluate the robustness and reproducibility of the volumetry methods. Conclusion Automatic volumetry and segmentation allows reliable detection of tumor growth and has the potential to increase reliability and significance of monitoring tumor growth in follow-up examinations. (orig.)

  18. Computing and Visualizing Reachable Volumes for Maneuvering Satellites

    Science.gov (United States)

    Jiang, M.; de Vries, W.; Pertica, A.; Olivier, S.

    2011-09-01

    Detecting and predicting maneuvering satellites is an important problem for Space Situational Awareness. The spatial envelope of all possible locations within reach of such a maneuvering satellite is known as the Reachable Volume (RV). As soon as custody of a satellite is lost, calculating the RV and its subsequent time evolution is a critical component in the rapid recovery of the satellite. In this paper, we present a Monte Carlo approach to computing the RV for a given object. Essentially, our approach samples all possible trajectories by randomizing thrust-vectors, thrust magnitudes and time of burn. At any given instance, the distribution of the "point-cloud" of the virtual particles defines the RV. For short orbital time-scales, the temporal evolution of the point-cloud can result in complex, multi-reentrant manifolds. Visualization plays an important role in gaining insight and understanding into this complex and evolving manifold. In the second part of this paper, we focus on how to effectively visualize the large number of virtual trajectories and the computed RV. We present a real-time out-of-core rendering technique for visualizing the large number of virtual trajectories. We also examine different techniques for visualizing the computed volume of probability density distribution, including volume slicing, convex hull and isosurfacing. We compare and contrast these techniques in terms of computational cost and visualization effectiveness, and describe the main implementation issues encountered during our development process. Finally, we will present some of the results from our end-to-end system for computing and visualizing RVs using examples of maneuvering satellites.

  19. Computing and Visualizing Reachable Volumes for Maneuvering Satellites

    International Nuclear Information System (INIS)

    Jiang, M.; de Vries, W.H.; Pertica, A.J.; Olivier, S.S.

    2011-01-01

    Detecting and predicting maneuvering satellites is an important problem for Space Situational Awareness. The spatial envelope of all possible locations within reach of such a maneuvering satellite is known as the Reachable Volume (RV). As soon as custody of a satellite is lost, calculating the RV and its subsequent time evolution is a critical component in the rapid recovery of the satellite. In this paper, we present a Monte Carlo approach to computing the RV for a given object. Essentially, our approach samples all possible trajectories by randomizing thrust-vectors, thrust magnitudes and time of burn. At any given instance, the distribution of the 'point-cloud' of the virtual particles defines the RV. For short orbital time-scales, the temporal evolution of the point-cloud can result in complex, multi-reentrant manifolds. Visualization plays an important role in gaining insight and understanding into this complex and evolving manifold. In the second part of this paper, we focus on how to effectively visualize the large number of virtual trajectories and the computed RV. We present a real-time out-of-core rendering technique for visualizing the large number of virtual trajectories. We also examine different techniques for visualizing the computed volume of probability density distribution, including volume slicing, convex hull and isosurfacing. We compare and contrast these techniques in terms of computational cost and visualization effectiveness, and describe the main implementation issues encountered during our development process. Finally, we will present some of the results from our end-to-end system for computing and visualizing RVs using examples of maneuvering satellites.

  20. Direct visualization of electroporation-assisted in vivo gene delivery to tumors using intravital microscopy – spatial and time dependent distribution

    Directory of Open Access Journals (Sweden)

    Dachs Gabi U

    2004-11-01

    Full Text Available Abstract Background Electroporation is currently receiving much attention as a way to increase drug and DNA delivery. Recent studies demonstrated the feasibility of electrogene therapy using a range of therapeutic genes for the treatment of experimental tumors. However, the transfection efficiency of electroporation-assisted DNA delivery is still low compared to viral methods and there is a clear need to optimize this approach. In order to optimize treatment, knowledge about spatial and time dependency of gene expression following delivery is of utmost importance in order to improve gene delivery. Intravital microscopy of tumors growing in dorsal skin fold window chambers is a useful method for monitoring gene transfection, since it allows non-invasive dynamic monitoring of gene expression in tumors in a live animal. Methods Intravital microscopy was used to monitor real time spatial distribution of the green fluorescent protein (GFP and time dependence of transfection efficiency in syngeneic P22 rat tumor model. DNA alone, liposome-DNA complexes and electroporation-assisted DNA delivery using two different sets of electric pulse parameters were compared. Results Electroporation-assisted DNA delivery using 8 pulses, 600 V/cm, 5 ms, 1 Hz was superior to other methods and resulted in 22% increase in fluorescence intensity in the tumors up to 6 days post-transfection, compared to the non-transfected area in granulation tissue. Functional GFP was detected within 5 h after transfection. Cells expressing GFP were detected throughout the tumor, but not in the surrounding tissue that was not exposed to electric pulses. Conclusions Intravital microscopy was demonstrated to be a suitable method for monitoring time and spatial distribution of gene expression in experimental tumors and provided evidence that electroporation-assisted gene delivery using 8 pulses, 600 V/cm, 5 ms, 1 Hz is an effective method, resulting in early onset and homogenous

  1. Personalized Computer-Assisted Mathematics Problem-Solving Program and Its Impact on Taiwanese Students

    Science.gov (United States)

    Chen, Chiu-Jung; Liu, Pei-Lin

    2007-01-01

    This study evaluated the effects of a personalized computer-assisted mathematics problem-solving program on the performance and attitude of Taiwanese fourth grade students. The purpose of this study was to determine whether the personalized computer-assisted program improved student performance and attitude over the nonpersonalized program.…

  2. Respiratory-Gated Helical Computed Tomography of Lung: Reproducibility of Small Volumes in an Ex Vivo Model

    International Nuclear Information System (INIS)

    Biederer, Juergen; Dinkel, Julien; Bolte, Hendrik; Welzel, Thomas; Hoffmann, Beata M.Sc.; Thierfelder, Carsten; Mende, Ulrich; Debus, Juergen; Heller, Martin; Kauczor, Hans-Ulrich

    2007-01-01

    Purpose: Motion-adapted radiotherapy with gated irradiation or tracking of tumor positions requires dedicated imaging techniques such as four-dimensional (4D) helical computed tomography (CT) for patient selection and treatment planning. The objective was to evaluate the reproducibility of spatial information for small objects on respiratory-gated 4D helical CT using computer-assisted volumetry of lung nodules in a ventilated ex vivo system. Methods and Materials: Five porcine lungs were inflated inside a chest phantom and prepared with 55 artificial nodules (mean diameter, 8.4 mm ± 1.8). The lungs were respirated by a flexible diaphragm and scanned with 40-row detector CT (collimation, 24 x 1.2 mm; pitch, 0.1; rotation time, 1 s; slice thickness, 1.5 mm; increment, 0.8 mm). The 4D-CT scans acquired during respiration (eight per minute) and reconstructed at 0-100% inspiration and equivalent static scans were scored for motion-related artifacts (0 or absent to 3 or relevant). The reproducibility of nodule volumetry (three readers) was assessed using the variation coefficient (VC). Results: The mean volumes from the static and dynamic inspiratory scans were equal (364.9 and 360.8 mm 3 , respectively, p = 0.24). The static and dynamic end-expiratory volumes were slightly greater (371.9 and 369.7 mm 3 , respectively, p = 0.019). The VC for volumetry (static) was 3.1%, with no significant difference between 20 apical and 20 caudal nodules (2.6% and 3.5%, p = 0.25). In dynamic scans, the VC was greater (3.9%, p = 0.004; apical and caudal, 2.6% and 4.9%; p = 0.004), with a significant difference between static and dynamic in the 20 caudal nodules (3.5% and 4.9%, p = 0.015). This was consistent with greater motion-related artifacts and image noise at the diaphragm (p <0.05). The VC for interobserver variability was 0.6%. Conclusion: Residual motion-related artifacts had only minimal influence on volumetry of small solid lesions. This indicates a high reproducibility of

  3. Noninvasive Evaluation of Metabolic Tumor Volume in Lewis Lung Carcinoma Tumor-Bearing C57BL/6 Mice with Micro-PET and the Radiotracers 18F-Alfatide and 18F-FDG: A Comparative Analysis.

    Directory of Open Access Journals (Sweden)

    Yu-Chun Wei

    Full Text Available To explore the value of a new simple lyophilized kit for labeling PRGD2 peptide (18F-ALF-NOTA-PRGD2, denoted as 18F-alfatide in the determination of metabolic tumor volume (MTV with micro-PET in lewis lung carcinoma (LLC tumor-bearing C57BL/6 mice verified by pathologic examination and compared with those using 18F-fluorodeoxyglucose (FDG PET.All LLC tumor-bearing C57BL/6 mice underwent two attenuation-corrected whole-body micro-PET scans with the radiotracers 18F-alfatide and 18F-FDG within two days. 18F-alfatide metabolic tumor volume (VRGD and 18F-FDG metabolic tumor volume (VFDG were manually delineated slice by slice on PET images. Pathologic tumor volume (VPath was measured in vitro after the xenografts were removed.A total of 37 mice with NSCLC xenografts were enrolled and 33 of them underwent 18F-alfatide PET, and 35 of them underwent 18F-FDG PET and all underwent pathological examination. The mean ± standard deviation of VPath, VRGD, and VFDG were 0.59±0.32 cm3 (range,0.13~1.64 cm3, 0.61±0.37 cm3 (range,0.15~1.86 cm3, and 1.24±0.53 cm3 (range,0.17~2.20 cm3, respectively. VPath vs. VRGD, VPath vs. VFDG, and VRGD vs. VFDG comparisons were t = -0.145, P = 0.885, t = -6.239, P<0.001, and t = -5.661, P<0.001, respectively. No significant difference was found between VPath and VRGD. VFDG was much larger than VRGD and VPath. VRGD seemed more approximate to the pathologic gross tumor volume. Furthermore, VPath was more strongly correlated with VRGD (R = 0.964,P<0.001 than with VFDG (R = 0.584,P<0.001.18F-alfatide PET provided a better estimation of gross tumor volume than 18F-FDG PET in LLC tumor-bearing C57BL/6 mice.

  4. Computer-assisted estimating for the Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Spooner, J.E.

    1976-02-01

    An analysis is made of the cost estimating system currently in use at the Los Alamos Scientific Laboratory (LASL) and the benefits of computer assistance are evaluated. A computer-assisted estimating system (CAE) is proposed for LASL. CAE can decrease turnaround and provide more flexible response to management requests for cost information and analyses. It can enhance value optimization at the design stage, improve cost control and change-order justification, and widen the use of cost information in the design process. CAE costs are not well defined at this time although they appear to break even with present operations. It is recommended that a CAE system description be submitted for contractor consideration and bid while LASL system development continues concurrently

  5. Computer-aided analysis of CT images for the differentiation of cerebral tumors

    International Nuclear Information System (INIS)

    Michalik, M.; Michalik, S.; Bornholdt, F.

    1988-01-01

    For the integration of CT imaging into the differential diagnostics of intracranial space occupations, the selection and description of characteristics facilitating a good discrimination of serveral classes of tumors becomes a very important task. From images of 93 patients with the most frequent brain tumors the optimal set of characteristics was determined. The four most significant characteristics for the differentiation of brain tumors are 'uptake of contrast medium by the tumor', 'deliniation of the tumor contours', 'progression of the tumor' and the 'average tumor density after administration of contrast media'. Very good results were obtained for the differentiation of menigneomas with and without anaplasia and for the differentiation of meningeomas from all other tumors examined. The differentiation of the degree of malignancy for various gliomatous tumors was difficult. An accurate reclassification with the computer program was obtained for 83.4% of all tumors. (author)

  6. Computer-based image studies on tumor nests mathematical features of breast cancer and their clinical prognostic value.

    Science.gov (United States)

    Wang, Lin-Wei; Qu, Ai-Ping; Yuan, Jing-Ping; Chen, Chuang; Sun, Sheng-Rong; Hu, Ming-Bai; Liu, Juan; Li, Yan

    2013-01-01

    The expending and invasive features of tumor nests could reflect the malignant biological behaviors of breast invasive ductal carcinoma. Useful information on cancer invasiveness hidden within tumor nests could be extracted and analyzed by computer image processing and big data analysis. Tissue microarrays from invasive ductal carcinoma (n = 202) were first stained with cytokeratin by immunohistochemical method to clearly demarcate the tumor nests. Then an expert-aided computer analysis system was developed to study the mathematical and geometrical features of the tumor nests. Computer recognition system and imaging analysis software extracted tumor nests information, and mathematical features of tumor nests were calculated. The relationship between tumor nests mathematical parameters and patients' 5-year disease free survival was studied. There were 8 mathematical parameters extracted by expert-aided computer analysis system. Three mathematical parameters (number, circularity and total perimeter) with area under curve >0.5 and 4 mathematical parameters (average area, average perimeter, total area/total perimeter, average (area/perimeter)) with area under curve nests could be a useful parameter to predict the prognosis of early stage breast invasive ductal carcinoma.

  7. Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy

    International Nuclear Information System (INIS)

    Shimizu, Shinichi; Shirato, Hiroki; Kagei, Kenji; Nishioka, Takeshi; Bo Xo; Dosaka-Akita, Hirotoshi; Hashimoto, Seiko; Aoyama, Hidefumi; Tsuchiya, Kazuhiko; Miyasaka, Kazuo

    2000-01-01

    Purpose: Three-dimensional (3D) treatment planning has often been performed while patients breathe freely, under the assumption that the computed tomography (CT) images represent the average position of the tumor. We investigated the impact of respiratory movement on the free-breathing CT images of small lung tumors using sequential CT scanning at the same table position. Methods: Using a preparatory free-breathing CT scan, the patient's couch was fixed at the position where each tumor showed its maximum diameter on image. For 16 tumors, over 20 sequential CT images were taken every 2 s, with a 1-s acquisition time occurring during free breathing. For each tumor, the distance between the surface of the CT table and the posterior border of the tumor was measured to determine whether the edge of the tumor was sufficiently included in the planning target volume (PTV) during normal breathing. Results: In the sequential CT scanning, the tumor itself was not visible in the examination slice in 21% (75/357) of cases. There were statistically significant differences between lower lobe tumors (39.4%, 71/180) and upper lobe tumors (0%, 0/89) (p < 0.01) and between lower lobe tumors and middle lobe tumor (8.9%, 4/45) (p < 0.01) in the incidence of the disappearance of the tumor from the image. The mean difference between the maximum and minimum distances between the surface of the CT table and the posterior border of the tumor was 6.4 mm (range 2.1-24.4). Conclusion: Three-dimensional treatment planning for lung carcinoma would significantly underdose many lesions, especially those in the lower lobe. The excess 'safety margin' might call into question any additional benefit of 3D treatment. More work is required to determine how to control respiratory movement

  8. Computer-assisted qualitative data analysis software.

    Science.gov (United States)

    Cope, Diane G

    2014-05-01

    Advances in technology have provided new approaches for data collection methods and analysis for researchers. Data collection is no longer limited to paper-and-pencil format, and numerous methods are now available through Internet and electronic resources. With these techniques, researchers are not burdened with entering data manually and data analysis is facilitated by software programs. Quantitative research is supported by the use of computer software and provides ease in the management of large data sets and rapid analysis of numeric statistical methods. New technologies are emerging to support qualitative research with the availability of computer-assisted qualitative data analysis software (CAQDAS).CAQDAS will be presented with a discussion of advantages, limitations, controversial issues, and recommendations for this type of software use.

  9. 18F-FDG PET/CT-based gross tumor volume definition for radiotherapy in head and neck Cancer: a correlation study between suitable uptake value threshold and tumor parameters

    International Nuclear Information System (INIS)

    Kao, Chia-Hung; Hsieh, Te-Chun; Yu, Chun-Yen; Yen, Kuo-Yang; Yang, Shih-Neng; Wang, Yao-Ching; Liang, Ji-An; Chien, Chun-Ru; Chen, Shang-Wen

    2010-01-01

    To define a suitable threshold setting for gross tumor volume (GTV) when using 18 Fluoro-deoxyglucose positron emission tomography and computed tomogram (PET/CT) for radiotherapy planning in head and neck cancer (HNC). Fifteen HNC patients prospectively received PET/CT simulation for their radiation treatment planning. Biological target volume (BTV) was derived from PET/CT-based GTV of the primary tumor. The BTVs were defined as the isodensity volumes when adjusting different percentage of the maximal standardized uptake value (SUVmax), excluding any artifact from surrounding normal tissues. CT-based primary GTV (C-pGTV) that had been previously defined by radiation oncologists was compared with the BTV. Suitable threshold level (sTL) could be determined when BTV value and its morphology using a certain threshold level was observed to be the best fitness of the C-pGTV. Suitable standardized uptake value (sSUV) was calculated as the sTL multiplied by the SUVmax. Our result demonstrated no single sTL or sSUV method could achieve an optimized volumetric match with the C-pGTV. The sTL was 13% to 27% (mean, 19%), whereas the sSUV was 1.64 to 3.98 (mean, 2.46). The sTL was inversely correlated with the SUVmax [sTL = -0.1004 Ln (SUVmax) + 0.4464; R 2 = 0.81]. The sSUV showed a linear correlation with the SUVmax (sSUV = 0.0842 SUVmax + 1.248; R 2 = 0.89). The sTL was not associated with the value of C-pGTVs. In PET/CT-based BTV for HNC, a suitable threshold or SUV level can be established by correlating with SUVmax rather than using a fixed threshold

  10. An accurate segmentation method for volumetry of brain tumor in 3D MRI

    Science.gov (United States)

    Wang, Jiahui; Li, Qiang; Hirai, Toshinori; Katsuragawa, Shigehiko; Li, Feng; Doi, Kunio

    2008-03-01

    Accurate volumetry of brain tumors in magnetic resonance imaging (MRI) is important for evaluating the interval changes in tumor volumes during and after treatment, and also for planning of radiation therapy. In this study, an automated volumetry method for brain tumors in MRI was developed by use of a new three-dimensional (3-D) image segmentation technique. First, the central location of a tumor was identified by a radiologist, and then a volume of interest (VOI) was determined automatically. To substantially simplify tumor segmentation, we transformed the 3-D image of the tumor into a two-dimensional (2-D) image by use of a "spiral-scanning" technique, in which a radial line originating from the center of the tumor scanned the 3-D image spirally from the "north pole" to the "south pole". The voxels scanned by the radial line provided a transformed 2-D image. We employed dynamic programming to delineate an "optimal" outline of the tumor in the transformed 2-D image. We then transformed the optimal outline back into 3-D image space to determine the volume of the tumor. The volumetry method was trained and evaluated by use of 16 cases with 35 brain tumors. The agreement between tumor volumes provided by computer and a radiologist was employed as a performance metric. Our method provided relatively accurate results with a mean agreement value of 88%.

  11. Optimization of the fractionated irradiation scheme considering physical doses to tumor and organ at risk based on dose–volume histograms

    Energy Technology Data Exchange (ETDEWEB)

    Sugano, Yasutaka [Graduate School of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0812 (Japan); Mizuta, Masahiro [Laboratory of Advanced Data Science, Information Initiative Center, Hokkaido University, Kita-11, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0811 (Japan); Takao, Seishin; Shirato, Hiroki; Sutherland, Kenneth L. [Department of Radiation Medicine, Graduate School of Medicine, Hokkaido University, Kita-15, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-8638 (Japan); Date, Hiroyuki, E-mail: date@hs.hokudai.ac.jp [Faculty of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku, Sapporo, Hokkaido 060-0812 (Japan)

    2015-11-15

    Purpose: Radiotherapy of solid tumors has been performed with various fractionation regimens such as multi- and hypofractionations. However, the ability to optimize the fractionation regimen considering the physical dose distribution remains insufficient. This study aims to optimize the fractionation regimen, in which the authors propose a graphical method for selecting the optimal number of fractions (n) and dose per fraction (d) based on dose–volume histograms for tumor and normal tissues of organs around the tumor. Methods: Modified linear-quadratic models were employed to estimate the radiation effects on the tumor and an organ at risk (OAR), where the repopulation of the tumor cells and the linearity of the dose-response curve in the high dose range of the surviving fraction were considered. The minimization problem for the damage effect on the OAR was solved under the constraint that the radiation effect on the tumor is fixed by a graphical method. Here, the damage effect on the OAR was estimated based on the dose–volume histogram. Results: It was found that the optimization of fractionation scheme incorporating the dose–volume histogram is possible by employing appropriate cell surviving models. The graphical method considering the repopulation of tumor cells and a rectilinear response in the high dose range enables them to derive the optimal number of fractions and dose per fraction. For example, in the treatment of prostate cancer, the optimal fractionation was suggested to lie in the range of 8–32 fractions with a daily dose of 2.2–6.3 Gy. Conclusions: It is possible to optimize the number of fractions and dose per fraction based on the physical dose distribution (i.e., dose–volume histogram) by the graphical method considering the effects on tumor and OARs around the tumor. This method may stipulate a new guideline to optimize the fractionation regimen for physics-guided fractionation.

  12. Ethical and Professional Issues in Computer-Assisted Therapy.

    Science.gov (United States)

    Ford, B. Douglas

    1993-01-01

    Discusses ethical and professional issues in psychology regarding computer-assisted therapy (CAT). Topics addressed include an explanation of CAT; whether CAT is psychotherapy; software, including independent use, validation of effectiveness, and restricted access; clinician resistance; client acceptance; the impact on ethical standards; and a…

  13. On the problem of possibilities of X-ray computer tomography in the diagnosis of endophitic tumors of the stomach

    International Nuclear Information System (INIS)

    Gorshkov, A.N.; Akberov, R.F.

    1996-01-01

    The possibilities of X-ray computer tomography in the diagnosis of endophitic tumors of the stomach including tumors of small size are considered using the examinations of 100 patients with stomach diseases. The computer-tomographic semiotics of small endophitic tumors of the stomach is presented, the place of computer tomography in the diagnosis of tumors of the stomach as well as its potential possibilities in revealing small tumors of the stomach with principally endophitic spreading. 10 refs.; 3 figs

  14. Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: Preoperative classification accuracy and histopathologic correlation

    International Nuclear Information System (INIS)

    Xyda, Argyro; Haberland, Ulrike; Klotz, Ernst; Jung, Klaus; Bock, Hans Christoph; Schramm, Ramona; Knauth, Michael; Schramm, Peter

    2012-01-01

    Background: To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods: Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as control. Correlations among perfusion values, tumor grade, cerebral hemisphere and VOIs were evaluated. Moreover, the diagnostic power of VPCT parameters, by means of positive and negative predictive value, was analyzed. Results: Our cohort included 32 high-grade gliomas WHO III/IV, 18 low-grade I/II, 6 primary cerebral lymphomas, 4 metastases and 3 tumor-like lesions. Ktrans demonstrated the highest sensitivity, specificity and positive predictive value, with a cut-off point of 2.21 mL/100 mL/min, for both the comparisons between high-grade versus low-grade and low-grade versus primary cerebral lymphomas. However, for the differentiation between high-grade and primary cerebral lymphomas, CBF and CBV proved to have 100% specificity and 100% positive predictive value, identifying preoperatively all the histopathologically proven high-grade gliomas. Conclusion: Volumetric perfusion data enable the hemodynamic assessment of the entire tumor extent and provide a method of preoperative differentiation among intra-axial cerebral tumors with promising diagnostic accuracy.

  15. From Computer Assisted Language Learning (CALL) to Mobile Assisted Language Use (MALU)

    Science.gov (United States)

    Jarvis, Huw; Achilleos, Marianna

    2013-01-01

    This article begins by critiquing the long-established acronym CALL (Computer Assisted Language Learning). We then go on to report on a small-scale study which examines how student non-native speakers of English use a range of digital devices beyond the classroom in both their first (L1) and second (L2) languages. We look also at the extent to…

  16. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  17. A case of ureteral tumor diagnosed by computed tomography

    International Nuclear Information System (INIS)

    Hirakawa, Shinji; Adachi, Botaro; Hamamoto, Ryuichi; Nishimoto, Kazuhiko; Goto, Hajime

    1980-01-01

    A 66-year-old woman, visited Tottori University Hospital with the chief complaint of asymptomatic macrohematuria on Oct. 4, 1979. RP showed right hydroureteronephrosis due to right lower ureteral stenosis. Computed tomography (CT) was employed to investigate the right lower ureter, which showed a tumor in the right lower ureter, confined within the ureteral wall. Diagnosis of the right ureteral tumor with right hydroureteronephrosis was made and under general anesthesia right complete nephroureterectomy was performed on Oct. 26, 1979. So, the accuracy of the preoperative diagnosis was confirmed by the operation. CT has been supposed to be disadvantageous in the diagnosis of ureteral lesions, since ureter is thin, and the ureteral wall is also thin. However as was demonstrated in this case, a sizeable tumor of ureter could be diagnosed accurately by CT. (author)

  18. Biological modelling of fuzzy target volumes in 3D radiotherapy

    International Nuclear Information System (INIS)

    Levegruen, S.; Kampen, M. van; Waschek, T.; Engenhart, R.; Schlegel, W.

    1995-01-01

    increase in NTCP is then calculated for a homogeneous dose distribution extending the boundaries of the volume considered towards the maximal PTV. Results: The behavior of the model and its dependence on the input parameters was investigated for the case of a brain tumor. Going from the minimal PTV towards the maximal PTV, the TCP increases show a sigmoidal shape. The increase in NTCP depends for each patient on the relative position of the organs at risk with respect to the region of uncertainty. We use the model as input into a computer assisted expert system based on Fuzzy Logic. Output of the Fuzzy system is the target volume which, for each individual patient, leads to the best compromise between high tumor control probability on one side and a low risk of complications on the other side. With this system the extent of the target volume towards noncritical structures is large, whereas the boundaries near an organ at risk within the region of uncertainty are strongly influenced by the partial volume of that organ at risk irradiated. Conclusion: At present biological models, in particular of TCP, suffer from a lack of data for the biological input parameters, especially for the density and distribution of clonogenic cells. The better these input parameters become established in the future, the more the model described here will serve as an important aid for the radiotherapist in the definition of the optimal target volume

  19. Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

    Science.gov (United States)

    Ahmad, Moiz; Balter, Peter; Pan, Tinsu

    2011-10-01

    Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4-6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3-8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm

  20. A robotic approach to 4D real-time tumor tracking for radiotherapy

    International Nuclear Information System (INIS)

    Buzurovic, I; Yu, Y; Huang, K; Podder, T K

    2011-01-01

    Respiratory and cardiac motions induce displacement and deformation of the tumor volumes in various internal organs. To accommodate this undesired movement and other errors, physicians incorporate a large margin around the tumor to delineate the planning target volume, so that the clinical target volume receives the prescribed radiation dose under any scenario. Consequently, a large volume of healthy tissue is irradiated and sometimes it is difficult to spare critical organs adjacent to the tumor. In this study we have proposed a novel approach to the 4D active tracking and dynamic delivery incorporating the tumor motion prediction technique. This method has been applied to the two commercially available robotic treatment couches. The proposed algorithm can predict the tumor position and the robotic systems are able to continuously track the tumor during radiation dose delivery. Therefore a precise dose is given to a moving target while the dose to the nearby critical organs is reduced to improve the patient treatment outcome. The efficacy of the proposed method has been investigated by extensive computer simulation. The tumor tracking method is simulated for two couches: HexaPOD robotic couch and ELEKTA Precise Table. The comparison results have been presented in this paper. In order to assess the clinical significance, dosimetric effects of the proposed method have been analyzed.

  1. Functional Response of Tumor Vasculature to PaCO2: Determination of Total and Microvascular Blood Volume by MRI

    Directory of Open Access Journals (Sweden)

    Scott D. Packard

    2003-07-01

    Full Text Available In order to identify differences in functional activity, we compared the reactivity of glioma vasculature and the native cerebral vasculature to both dilate and constrict in response to altered PaCO2. Gliomas were generated by unilateral implantation of U87MGdEGFR human glioma tumor cells into the striatum of adult female athymic rats. Relative changes in total and microvascular cerebral blood volume were determined by steady state contrast agent-enhanced magnetic resonance imaging for transitions from normocarbia to hypercarbia and hypocarbia. Although hypercarbia induced a significant increase in both total and microvascular blood volume in normal brain and glioma, reactivity of glioma vasculature was significantly blunted in comparison to normal striatum; glioma total CBV increased by 0.6±0.1%/mm Hg CO2 whereas normal striatum increased by 1.5±0.2%/mm Hg CO2, (P < .0001, group t-test. Reactivity of microvascular blood volume was also significantly blunted. In contrast, hypocarbia decreased both total and microvascular blood volumes more in glioma than in normal striatum. These results indicate that cerebral blood vessels derived by tumor-directed angiogenesis do retain reactivity to CO2. Furthermore, reduced reactivity of tumor vessels to a single physiological perturbation, such as hypercarbia, should not be construed as a generalized reduction of functional activity of the tumor vascular bed.

  2. 45 CFR 233.35 - Computing the assistance payment under retrospective budgeting after the initial one or two...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Computing the assistance payment under... FINANCIAL ASSISTANCE PROGRAMS § 233.35 Computing the assistance payment under retrospective budgeting after... shall be computed retrospectively, i.e., shall be based on income and other relevant circumstances in...

  3. Clinical studies of cerebral blood flows using single photon emission computed tomography (SPECT), 1; The remote effects of tumors and the adverse effects of radiochemotherapy in the non-affected brain of patients with intracranial tumors

    Energy Technology Data Exchange (ETDEWEB)

    Araki, Yuzo (Gifu Univ. (Japan). Faculty of Medicine)

    1991-01-01

    To examine remote effects of tumors on cerebral blood flow (CBF) and adverse effects of radiochemotherapy on cerebral and cerebellar blood flow (CeBF), mean CBF (mCBF) and mean CeBF (mCeBF) have been studied by single photon emission computed tomography (SPECT) with Xe-133. The subjects were 78 patients with brain tumor, whose ages ranged from 9 to 74 years. Forty normal volunteers served as controls. In the control group, both mCBF and mCeBF were significantly decreased with advancing age. Both ipsilateral and contralateral mCeBFs were significantly decreased in adult patients with bilateral cerebral tumor, as compared with the control group, which was dependent on tumor volume. mCeBF was significantly decreased on the contralataral side than on the ipsilataral side. Similarly, ipsilateral mCBF was significantly lower than that in the control group. Crossed cerebellar diaschisis occurred frequently associated with extensive involvement of tumor into the frontal, parietal, and temporal lobes. In adult patients, a decreased mCBF on the non-affected side before surgery was improved postoperatively. One month after irradiation, it transiently increased and decreased again. Three months after irradiation, mCBF was significantly decreased, as compared with that in the control group. The degree of atrophy and tumor volume influenced mCBF on the non-affected side. These factors were responsible for mCBF in younger patients for the adult group, and in older patients for the child group. For adult patients, radiation dose was also a contributing factor for mCBF. In the group given chemotherapy, mCBF was significantly decreased, as compared with the group without chemotherapy. (N.K.) 102 refs.

  4. Analysis of tumor-like shadows on abdominal plain x-ray film

    International Nuclear Information System (INIS)

    Hayashi, Hidehiro; Hiraki, Yoshio; Hashimoto, Keizi

    1986-01-01

    We found tumor-like shadows in the upper abdomen in 93 cases out of 400 abdominal plain films, although none of these 93 cases actually had a tumor. We analyzed these tumor-like shadows by computed tomography. For each of the 400 cases we measured the width of flank stripe on the abdominal plain film. Most of the tumor-like shadows in the left upper abdomen were gastric fundus, but it was significant for evaluating plain abdominal film that other organs such as a part of the left lobe of the liver, the upper pole of the left kidney, and a part of the spleen formed tumor-like shadows. The most important factors forming tumor-like shadows on plain abdominal film are the fat volume of the abdominal cauity as well as the fraciform ligament and alterations in the shape and volume of organs such as occur in liver cirrhosis. (author)

  5. Liver tumors, correlation of computed tomography (CT) and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Okazaki, Atsushi; Niibe, Hideo; Mitsuhashi, Norio

    1984-09-01

    Computed tomographic and pathologic correlation was studied in 12 autopsied cases with 11 cases of metastatic liver tumors and 1 case of hepatocellular carcinoma. Despite of proliferative patterns of the tumors, nodular low attenuations on CT showed scattered nodular lesions and geographic low attenuations on CT showed groups of multiple small nodular lesions, macroscopically. Abnormal areas of low attenuation were generally diminished by drip infusion contrast enhancement, which was more significant on tumors of infiltrative proliferation. Tumors of infiltrative proliferation revealed little degeneration of surrounding liver cells and abnormal areas of low attenuation were more distinct before contrast enhancement. Tumors of expansive proliferation revealed obvious degeneration of surrounding liver cells and a case having about 200 layers of degenerated liver cells revealed more distinct after contrast enhancement. The central lower density areas in abnormal areas of low attenuation on CT coincided with liquefactive necroses with scanty capillary. vessels and fibrotic changes, histopathologically. But coagulative necroses without decrease of surrouding blood flows were not visualized on CT. CT could not demonstrate the liquefactive necroses in more small nodules than 2 cm in diameter. (J.P.N.).

  6. Clinical Implementation of Intrafraction Cone Beam Computed Tomography Imaging During Lung Tumor Stereotactic Ablative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ruijiang; Han, Bin; Meng, Bowen [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G.; Xing, Lei; Koong, Albert C. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Diehn, Maximilian, E-mail: Diehn@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Institute for Stem Cell Biology and Regenerative Medicine, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2013-12-01

    Purpose: To develop and clinically evaluate a volumetric imaging technique for assessing intrafraction geometric and dosimetric accuracy of stereotactic ablative radiation therapy (SABR). Methods and Materials: Twenty patients received SABR for lung tumors using volumetric modulated arc therapy (VMAT). At the beginning of each fraction, pretreatment cone beam computed tomography (CBCT) was used to align the soft-tissue tumor position with that in the planning CT. Concurrent with dose delivery, we acquired fluoroscopic radiograph projections during VMAT using the Varian on-board imaging system. Those kilovolt projections acquired during millivolt beam-on were automatically extracted, and intrafraction CBCT images were reconstructed using the filtered backprojection technique. We determined the time-averaged target shift during VMAT by calculating the center of mass of the tumor target in the intrafraction CBCT relative to the planning CT. To estimate the dosimetric impact of the target shift during treatment, we recalculated the dose to the GTV after shifting the entire patient anatomy according to the time-averaged target shift determined earlier. Results: The mean target shift from intrafraction CBCT to planning CT was 1.6, 1.0, and 1.5 mm; the 95th percentile shift was 5.2, 3.1, 3.6 mm; and the maximum shift was 5.7, 3.6, and 4.9 mm along the anterior-posterior, left-right, and superior-inferior directions. Thus, the time-averaged intrafraction gross tumor volume (GTV) position was always within the planning target volume. We observed some degree of target blurring in the intrafraction CBCT, indicating imperfect breath-hold reproducibility or residual motion of the GTV during treatment. By our estimated dose recalculation, the GTV was consistently covered by the prescription dose (PD), that is, V100% above 0.97 for all patients, and minimum dose to GTV >100% PD for 18 patients and >95% PD for all patients. Conclusions: Intrafraction CBCT during VMAT can provide

  7. Generative Computer Assisted Instruction: An Application of Artificial Intelligence to CAI.

    Science.gov (United States)

    Koffman, Elliot B.

    Frame-oriented computer-assisted instruction (CAI) systems dominate the field, but these mechanized programed texts utilize the computational power of the computer to a minimal degree and are difficult to modify. Newer, generative CAI systems which are supplied with a knowledge of subject matter can generate their own problems and solutions, can…

  8. Computer-assisted instruction; MR imaging of congenital heart disease

    International Nuclear Information System (INIS)

    Choi, Young Hi; Yu, Pil Mun; Lee, Sang Hoon; Choe, Yeon Hyeon; Kim, Yang Min

    1996-01-01

    To develop a software program for computer-assisted instruction on MR imaging of congenital heart disease for medical students and residents to achieve repetitive and effective self-learning. We used a film scanner(Scan Maker 35t) and IBM-PC(486 DX-2, 60 MHz) for acquisition and storage of image data. The accessories attached to the main processor were CD-ROM drive(Sony), sound card(Soundblaster-Pro), and speaker. We used software of Adobe Photoshop(v 3.0) and paint shop-pro(v 3.0) for preprocessing image data, and paintbrush from microsoft windows 3.1 for labelling. The language used for programming was visual basic(v 3.0) from microsoft corporation. We developed a software program for computer-assisted instruction on MR imaging of congenital heart disease as an effective educational tool

  9. Aberrant paramagnetic signals outside the tumor volume on routine surveillance MRI of brain tumor patients.

    Science.gov (United States)

    Yust-Katz, Shlomit; Inbar, Edna; Michaeli, Natalia; Limon, Dror; Siegal, Tali

    2017-09-01

    Late complications of cerebral radiation therapy (RT) involve vascular injury with acquired cavernous malformation, telangiectasias and damage to vascular walls which are well recognized in children. Its incidence in adults is unknown. Blood products and iron deposition that accompany vascular injury create paramagnetic effects on MRI. This study retrospectively investigated the frequency of paramagnetic lesions on routine surveillance MRI of adult brain tumor patients. MRI studies of 115 brain tumor patients were reviewed. Only studies containing sequences of either susceptibility weighted images or gradient echo or blood oxygenation level dependent imaging were included. Lesions inside the tumor volume were not considered. 68 studies fulfilled the above criteria and included 48 patients with previous RT (35 followed for >2 years and 13 for 1 year) and 20 patients who were not treated with RT. The median age at time of irradiation was 47 years. Aberrant paramagnetic lesions were found in 23/35 (65%) patients followed for >2 years after RT and in only 1/13 (8%) patients followed for 1-year after radiation (p = 0.03). The 1-year follow-up group did not differ from the control group [2/20 (9%)]. Most lesions were within the radiation field and none of the patients had related symptomatology. The number and incidence of these lesions increased with time and amounted to 75% over 3 years post RT. MRI paramagnetic signal aberrations are common findings in adult brain tumor patients that evolve over time after RT. The clinical significance of these lesions needs further investigation.

  10. Computer Assisted Project-Based Instruction: The Effects on Science Achievement, Computer Achievement and Portfolio Assessment

    Science.gov (United States)

    Erdogan, Yavuz; Dede, Dinçer

    2015-01-01

    The purpose of this study is to compare the effects of computer assisted project-based instruction on learners' achievement in a science and technology course, in a computer course and in portfolio development. With this aim in mind, a quasi-experimental design was used and a sample of 70 seventh grade secondary school students from Org. Esref…

  11. Computational Modeling of Medical Images of Brain Tumor Patients for Optimized Radiation Therapy Planning

    DEFF Research Database (Denmark)

    Agn, Mikael

    In brain tumor radiation therapy, the aim is to maximize the delivered radiation dose to the targeted tumor and at the same time minimize the dose to sensitive healthy structures – so-called organs-at-risk (OARs). When planning a radiation therapy session, the tumor and the OARs therefore need...... to be delineated on medical images of the patient’s head, to be able to optimize a radiation dose plan. In clinical practice, the delineation is performed manually with limited assistance from automatic procedures, which is both time-consuming and typically suffers from poor reproducibility. There is, therefore...

  12. The role of computed tomography in the diagnosis and treatment of malignant tumors of the nasal cavity, paranasal sinuses and nasopharynx

    International Nuclear Information System (INIS)

    Kondo, Makoto; Yamashita, Shoji; Inuyama, Yukio; Shiga, Hayao; Hashimoto, Shozo

    1986-01-01

    We studied the value of computed tomography (CT) in diagnosis and treatment of primary malignant tumors of the sinonasal cavities and nasopharynx, and reached the following conclusions. 1) In maxillary carcinomas, bone destruction is always seen on CT. When bone destruction is not apparent despite invasion to the adjacent site, malignant lymphoma or plasmacytoma is suggested. 2) In defining the tumor extent of maxillary SCC, CT is more reliable than maxillotomy, and is equal to maxillectomy. However, clouding of the sinus without bone destruction remains a problem, since this finding can be caused by either tumor invasion or obstructive sinusitis. 3) In maxillary and nasopharyngeal SCC, CT frequently reveals tumors to be more extensive than previously suspected following physical and conventional x-ray examinations. Therefore, the T-stages of these tumors are often upstaged to more advanced ones. 4) CT is of great help in identifying candidates for surgery in maxillary SCC, and in planning radiation therapy for nasopharyngeal and sinonasal tumors. Dose distribution curves displayed directly on the CT slices are becoming essential tools for radiation oncologists. After the introduction of CT, treatment results in cases of nasopharyngeal SCC have improved, probably due to better definition of the tumor volumes. 5) CT is also used for observing tumor response after therapy and for follow-up. In summary, CT is now indispensable in the management of malignant tumors of these sites. (author)

  13. Carbogen Breathing Differentially Enhances Blood Plasma Volume and 5-Fluorouracil Uptake in Two Murine Colon Tumor Models with a Distinct Vascular Structure

    Directory of Open Access Journals (Sweden)

    Hanneke W.M. van Laarhoven

    2006-06-01

    Full Text Available For the systemic treatment of colorectal cancer, 5-fluorouracil (FU-based chemotherapy is the standard. However, only a subset of patients responds to chemotherapy. Breathing of carbogen (95% O2 and 5% CO2 may increase the uptake of FU through changes in tumor physiology. This study aims to monitor in animal models in vivo the effects of carbogen breathing on tumor blood plasma volume, pH, and energy status, and on FU uptake and metabolism in two colon tumor models C38 and C26a, which differ in their vascular structure and hypoxic status. Phosphorus-31 magnetic resonance spectroscopy (MRS was used to assess tumor pH and energy status, and fluorine-19 MRS was used to follow FU uptake and metabolism. Advanced magnetic resonance imaging methods using ultrasmall particles of iron oxide were performed to assess blood plasma volume. The results showed that carbogen breathing significantly decreased extracellular pH and increased tumor blood plasma volume and FU uptake in tumors. These effects were most significant in the C38 tumor line, which has the largest relative vascular area. In the C26a tumor line, carbogen breathing increased tumor growth delay by FU. In this study, carbogen breathing also enhanced systemic toxicity by FU.

  14. Comparison between CT volume measurement and histopathological assessment of response to neoadjuvant therapy in rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pomerri, Fabio, E-mail: fabio.pomerri@unipd.it [Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padua (Italy); Department of Medicine, University of Padua, via Giustiniani 2, 35128 Padua (Italy); Pucciarelli, Salvatore, E-mail: puc@unipd.it [Department of Oncological and Surgical Sciences, University of Padua, via Giustiniani 2, 35128 Padua (Italy); Gennaro, Gisella, E-mail: gisella.gennaro@pd.infn.it [Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padua (Italy); Maretto, Isacco, E-mail: isac77@gmail.com [Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padua (Italy); Nitti, Donato, E-mail: donato.nitti@unipd.it [Department of Oncological and Surgical Sciences, University of Padua, via Giustiniani 2, 35128 Padua (Italy); Muzzio, Pier Carlo, E-mail: pcmuzzio@unipd.it [Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padua (Italy)

    2012-12-15

    Objectives: The aim of this study was to compare volume measurements on computed tomography (CT) images with histopathological assessments of chemoradiotherapy (CRT)-induced tumor regression in locally advanced rectal cancer (RC). Methods: In 25 patients (13 males, 12 females; median age, 63 years; age range, 44–79 years) with locally advanced RC treated with preoperative CRT and surgery, two radiologists measured tumor volume on CT images before and after CRT. CT-based tumor volumetry and the modified response evaluation criteria in solid tumors (mRECISTs) were compared with T and N downstaging after CRT, and with the tumor regression grade (TRG). Results: Tumor volumes were significantly smaller on CT images after CRT. The tumors regressed in 52% (13/25), 36% (9/25) and 40% (10/25) of patients, based on T downstaging, TRG and mRECIST findings, respectively. In terms of T downstaging, the pre- and post-CRT tumor volumes of responders and non-responders to the treatment differed statistically, while their tumor volume reduction rates and volume reductions according to the 65% mRECIST threshold did not. In terms of N downstaging and TRG, the differences between the responders’ and the non-responders’ pre- and post-CRT tumor volumes, tumor volume reduction rates, and mRECIST thresholds were never statistically significant. Conclusion: Measuring tumor size on CT images is of limited value in predicting the histopathological response to preoperative CRT in RC patients, so it may be unwise to select surgical treatment strategies based on CT volumetry.

  15. Computer-Vision-Assisted Palm Rehabilitation With Supervised Learning.

    Science.gov (United States)

    Vamsikrishna, K M; Dogra, Debi Prosad; Desarkar, Maunendra Sankar

    2016-05-01

    Physical rehabilitation supported by the computer-assisted-interface is gaining popularity among health-care fraternity. In this paper, we have proposed a computer-vision-assisted contactless methodology to facilitate palm and finger rehabilitation. Leap motion controller has been interfaced with a computing device to record parameters describing 3-D movements of the palm of a user undergoing rehabilitation. We have proposed an interface using Unity3D development platform. Our interface is capable of analyzing intermediate steps of rehabilitation without the help of an expert, and it can provide online feedback to the user. Isolated gestures are classified using linear discriminant analysis (DA) and support vector machines (SVM). Finally, a set of discrete hidden Markov models (HMM) have been used to classify gesture sequence performed during rehabilitation. Experimental validation using a large number of samples collected from healthy volunteers reveals that DA and SVM perform similarly while applied on isolated gesture recognition. We have compared the results of HMM-based sequence classification with CRF-based techniques. Our results confirm that both HMM and CRF perform quite similarly when tested on gesture sequences. The proposed system can be used for home-based palm or finger rehabilitation in the absence of experts.

  16. The Effects of Computer-assisted and Distance Learning of Geometric Modeling

    Directory of Open Access Journals (Sweden)

    Omer Faruk Sozcu

    2013-01-01

    Full Text Available The effects of computer-assisted and distance learning of geometric modeling and computer aided geometric design are studied. It was shown that computer algebra systems and dynamic geometric environments can be considered as excellent tools for teaching mathematical concepts of mentioned areas, and distance education technologies would be indispensable for consolidation of successfully passed topics

  17. 16th International Conference on Medical Image Computing and Computer Assisted Intervention

    CERN Document Server

    Klinder, Tobias; Li, Shuo

    2014-01-01

    This book contains the full papers presented at the MICCAI 2013 workshop Computational Methods and Clinical Applications for Spine Imaging. The workshop brought together researchers representing several fields, such as Biomechanics, Engineering, Medicine, Mathematics, Physics and Statistic. The works included in this book present and discuss new trends in those fields, using several methods and techniques in order to address more efficiently different and timely applications involving signal and image acquisition, image processing and analysis, image segmentation, image registration and fusion, computer simulation, image based modelling, simulation and surgical planning, image guided robot assisted surgical and image based diagnosis.

  18. Computed tomography of tumors of paranasal sinuses and face

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sun Wha [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1982-09-15

    The computed tomography can image both bone and soft tissue structures of paranasal sinuses and face and so CT has added an important new dimension to radiological evaluation of disease of paranasal sinuses and face. CT is more accurate method of staging of tumors and essential for therapeutic planning. The author studied 25 cases of proven tumors of paranasal sinuses and face during the period from October 1977 to August 1980 in Kyung Hee University Hospital. The results were as follows: 1. Among 14 females and 11 male, their age range was from 14 years to 65 year. 2. The distribution of tumors were mucocele, squamous cell carcinoma, metastatic carcinoma, meningioma, angiofibroma, Masson's hemangiosarcoma, fibrous dysplasia, neurogenic sarcoma, Schwannoma, hemangioma, epidermoid, transitional cell carcinoma and unknown. 3. Determination of location and extent of mucocele was easily done by CT. Thus in all cases of ethmoid mucocele, chief complaint of exophthalmos could be easily explained by identification of its extension into peripheral fat space of orbit. 4. It is our belief that CT was useful method to determine staging of tumors of paranasal sinuses and was essential in choosing appropriate treatment modality. 5. The contrast enhancement is generally not helpful in pathologic diagnosis of tumors but intracranial extension of tumors are clearly defined by contrast enhancement.

  19. Two-Cloud-Servers-Assisted Secure Outsourcing Multiparty Computation

    Science.gov (United States)

    Wen, Qiaoyan; Zhang, Hua; Jin, Zhengping; Li, Wenmin

    2014-01-01

    We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users' public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function. PMID:24982949

  20. Two-cloud-servers-assisted secure outsourcing multiparty computation.

    Science.gov (United States)

    Sun, Yi; Wen, Qiaoyan; Zhang, Yudong; Zhang, Hua; Jin, Zhengping; Li, Wenmin

    2014-01-01

    We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users' public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function.

  1. A new method of three-dimensional computer assisted reconstruction of the developing biliary tract.

    Science.gov (United States)

    Prudhomme, M; Gaubert-Cristol, R; Jaeger, M; De Reffye, P; Godlewski, G

    1999-01-01

    A three-dimensional (3-D) computer assisted reconstruction of the biliary tract was performed in human and rat embryos at Carnegie stage 23 to describe and compare the biliary structures and to point out the anatomic relations between the structures of the hepatic pedicle. Light micrograph images from consecutive serial sagittal sections (diameter 7 mm) of one human and 16 rat embryos were directly digitalized with a CCD camera. The serial views were aligned automatically by software. The data were analysed following segmentation and thresholding, allowing automatic reconstruction. The main bile ducts ascended in the mesoderm of the hepatoduodenal ligament. The extrahepatic bile ducts: common bile duct (CD), cystic duct and gallbladder in the human, formed a compound system which could not be shown so clearly in histologic sections. The hepato-pancreatic ampulla was studied as visualised through the duodenum. The course of the CD was like a chicane. The gallbladder diameter and length were similar to those of the CD. Computer-assisted reconstruction permitted easy acquisition of the data by direct examination of the sections through the microscope. This method showed the relationships between the different structures of the hepatic pedicle and allowed estimation of the volume of the bile duct. These findings were not obvious in two-dimensional (2-D) views from histologic sections. Each embryonic stage could be rebuilt in 3-D, which could introduce the time as a fourth dimension, fundamental for the study of organogenesis.

  2. Computer-assisted diagnosis of melanoma.

    Science.gov (United States)

    Fuller, Collin; Cellura, A Paul; Hibler, Brian P; Burris, Katy

    2016-03-01

    The computer-assisted diagnosis of melanoma is an exciting area of research where imaging techniques are combined with diagnostic algorithms in an attempt to improve detection and outcomes for patients with skin lesions suspicious for malignancy. Once an image has been acquired, it undergoes a processing pathway which includes preprocessing, enhancement, segmentation, feature extraction, feature selection, change detection, and ultimately classification. Practicality for everyday clinical use remains a vital question. A successful model must obtain results that are on par or outperform experienced dermatologists, keep costs at a minimum, be user-friendly, and be time efficient with high sensitivity and specificity. ©2015 Frontline Medical Communications.

  3. Influence of postsurgical residual tumor volume on local control in radiotherapy for maxillary sinus cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kawashima, Mitsuhiko; Ogino, Takashi; Hayashi, Ryuichi; Ishikura, Satoshi; Nihei, Keiji; Ito, Yoshinori; Ikeda, Hiroshi; Ebihara, Satoshi [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East; Itai, Yuji

    2001-05-01

    The aim was to study the influence of postsurgical gross residual tumor volume on local control of maxillary sinus cancer treated with radiotherapy combined with debulking surgery. Forty-three patients who underwent combined surgery and radiotherapy (50-72 Gy, median 60 Gy) for squamous cell carcinoma of the maxillary sinus were reviewed. Gross residual tumor volume (GRTV) after surgery was measured on computed tomograms obtained during the radiotherapy planning. Patients were classified according to GRTV as follows: group AA, GRTV=0 (microscopic residual, n=2); group A, GRTV <10 cm{sup 3} (n=24); group B, 10-40 cm{sup 3} (n=9); and group C, {>=}40 cm{sup 3} (n=8). The relationship between local control and GRTV was analyzed using univariate and multivariate analysis. The 2-year local control rate for all patients was 62%. The differences in local control rates between groups AA, A and B were not significant (P<0.05), but the rate was significantly lower in group C than in the other groups (69% at 2 years vs 31% at 1 year, P<0.001). Multivariate analysis showed that GRTV (P=0.002) and histological differentiation (poorly differentiated histology was favorable, P=0.035) were independent prognostic factors and that intraarterial chemotherapy and administered total dose were not. Local control in groups A and B significantly depended on the total dose of radiotherapy, with 2-year control rates of patients receiving 50 Gy (n=6) and {>=}60 Gy (n=27) of 17% vs 79%, respectively (P<0.001). Our data suggest that adequate, not complete, debulking associated with a total radiotherapy dose of {>=}60 Gy can provide satisfactory local control for patients with squamous cell carcinoma of the maxillary sinus. (author)

  4. A method for partial volume correction of PET-imaged tumor heterogeneity using expectation maximization with a spatially varying point spread function

    International Nuclear Information System (INIS)

    Barbee, David L; Holden, James E; Nickles, Robert J; Jeraj, Robert; Flynn, Ryan T

    2010-01-01

    Tumor heterogeneities observed in positron emission tomography (PET) imaging are frequently compromised by partial volume effects which may affect treatment prognosis, assessment or future implementations such as biologically optimized treatment planning (dose painting). This paper presents a method for partial volume correction of PET-imaged heterogeneous tumors. A point source was scanned on a GE Discovery LS at positions of increasing radii from the scanner's center to obtain the spatially varying point spread function (PSF). PSF images were fit in three dimensions to Gaussian distributions using least squares optimization. Continuous expressions were devised for each Gaussian width as a function of radial distance, allowing for generation of the system PSF at any position in space. A spatially varying partial volume correction (SV-PVC) technique was developed using expectation maximization (EM) and a stopping criterion based on the method's correction matrix generated for each iteration. The SV-PVC was validated using a standard tumor phantom and a tumor heterogeneity phantom and was applied to a heterogeneous patient tumor. SV-PVC results were compared to results obtained from spatially invariant partial volume correction (SINV-PVC), which used directionally uniform three-dimensional kernels. SV-PVC of the standard tumor phantom increased the maximum observed sphere activity by 55 and 40% for 10 and 13 mm diameter spheres, respectively. Tumor heterogeneity phantom results demonstrated that as net changes in the EM correction matrix decreased below 35%, further iterations improved overall quantitative accuracy by less than 1%. SV-PVC of clinically observed tumors frequently exhibited changes of ±30% in regions of heterogeneity. The SV-PVC method implemented spatially varying kernel widths and automatically determined the number of iterations for optimal restoration, parameters which are arbitrarily chosen in SINV-PVC. Comparing SV-PVC to SINV-PVC demonstrated

  5. Variation of gross tumor volume and clinical target volume definition for lung cancer

    International Nuclear Information System (INIS)

    Liang Jun; Li Minghui; Chen Dongdu

    2011-01-01

    Objective: To study the variation of gross tumor volume (GTV) and clinical target volume (CTV) definition for lung cancer between different doctors. Methods: Ten lung cancer patients with PET-CT simulation were selected from January 2008 to December 2009.GTV and CTV of these patients were defined by four professors or associate professors of radiotherapy independently. Results: The mean ratios of largest to smallest GTV and CTV were 1.66 and 1.65, respectively. The mean coefficients of variation for GTV and CTV were 0.20 and 0.17, respectively. System errors of CTV definition in three dimension were less than 5 mm, which was the largest in inferior and superior (0.48 cm, 0.37 cm, 0.32 cm; F=0.40, 0.60, 0.15, P=0.755, 0.618, 0.928). Conclusions: The variation of GTV and CTV definition for lung cancer between different doctors exist. The mean ratios of largest to smallest GTV and CTV were less than 1.7. The variation was in hilar and mediastinum lymphanode regions. System error of CTV definition was the largest (<5 mm) in cranio-caudal direction. (authors)

  6. Computed tomography in the treatment of cervical spinal cord tumors

    International Nuclear Information System (INIS)

    Shin, Hideo

    1984-01-01

    Computed tomography (CT) of the cervical and thoracic spinal column was carried out in 12 patients of spinal cord tumor. There were 6 schwannomas, 2 metastatic tumors and other 4 cases of different tumors, which were studied by either a General Electric CT/T or a Toshiba TCT 60 Type A scanner. In all patients, CT-examination followed conventional spinal X-ray studies. The usefulness of the plain spinal CT (PCT: CT without any contrast enhancement neither intravenously nor intrathecally) was to detect subtle bony changes as well as paraspinal soft tissue abnormalities, although it was hard to distinguish the spinal cord by PCT. Metrizamide CT myelography (CTM: CT with intrathecal instillation of metrizamide) was indispensable to identify the intracanalicular architecture. It provided the clue to determine the site and the size of tumor, and it was also useful after surgical procedure. CTM with intravenous contrast enhancement (CTM-CE) together with CTM distinguished the spinal tumor from the spinal cord very well, particularly in the cases of schwannoma. The author supports significant reliability of PCT, CTM and CTM-CE in identifying the presence, the extension and the bony involvement of spinal cord tumors. (author)

  7. The current status and future prospects of computer-assisted hip surgery.

    Science.gov (United States)

    Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-03-01

    The advances in computer assistance technology have allowed detailed three-dimensional preoperative planning and simulation of preoperative plans. The use of a navigation system as an intraoperative assistance tool allows more accurate execution of the preoperative plan, compared to manual operation without assistance of the navigation system. In total hip arthroplasty using CT-based navigation, three-dimensional preoperative planning with computer software allows the surgeon to determine the optimal angle of implant placement at which implant impingement is unlikely to occur in the range of hip joint motion necessary for daily activities of living, and to determine the amount of three-dimensional correction for leg length and offset. With the use of computer navigation for intraoperative assistance, the preoperative plan can be precisely executed. In hip osteotomy using CT-based navigation, the navigation allows three-dimensional preoperative planning, intraoperative confirmation of osteotomy sites, safe performance of osteotomy even under poor visual conditions, and a reduction in exposure doses from intraoperative fluoroscopy. Positions of the tips of chisels can be displayed on the computer monitor during surgery in real time, and staff other than the operator can also be aware of the progress of surgery. Thus, computer navigation also has an educational value. On the other hand, its limitations include the need for placement of trackers, increased radiation exposure from preoperative CT scans, and prolonged operative time. Moreover, because the position of a bone fragment cannot be traced after osteotomy, methods to find its precise position after its movement need to be developed. Despite the need to develop methods for the postoperative evaluation of accuracy for osteotomy, further application and development of these systems are expected in the future. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  8. Effectiveness of Computer-Assisted Mathematics Education (CAME) over Academic Achievement: A Meta-Analysis Study

    Science.gov (United States)

    Demir, Seda; Basol, Gülsah

    2014-01-01

    The aim of the current study is to determine the overall effects of Computer-Assisted Mathematics Education (CAME) on academic achievement. After an extensive review of the literature, studies using Turkish samples and observing the effects of Computer-Assisted Education (CAE) on mathematics achievement were examined. As a result of this…

  9. 45 CFR 233.34 - Computing the assistance payment in the initial one or two months (AFDC).

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Computing the assistance payment in the initial... § 233.34 Computing the assistance payment in the initial one or two months (AFDC). A State shall compute...) If the initial month is computed prospectively as in paragraph (a) of this section, the second month...

  10. A Look at Computer-Assisted Testing Operations. The Illinois Series on Educational Application of Computers, No. 12e.

    Science.gov (United States)

    Muiznieks, Viktors; Dennis, J. Richard

    In computer assisted test construction (CATC) systems, the computer is used to perform the mechanical aspects of testing while the teacher retains control over question content. Advantages of CATC systems include question banks, decreased importance of test item security, computer analysis and response to student test answers, item analysis…

  11. Does Motion Assessment With 4-Dimensional Computed Tomographic Imaging for Non–Small Cell Lung Cancer Radiotherapy Improve Target Volume Coverage?

    Directory of Open Access Journals (Sweden)

    Naseer Ahmed

    2017-03-01

    Full Text Available Introduction: Modern radiotherapy with 4-dimensional computed tomographic (4D-CT image acquisition for non–small cell lung cancer (NSCLC captures respiratory-mediated tumor motion to provide more accurate target delineation. This study compares conventional 3-dimensional (3D conformal radiotherapy (3DCRT plans generated with standard helical free-breathing CT (FBCT with plans generated on 4D-CT contoured volumes to determine whether target volume coverage is affected. Materials and methods: Fifteen patients with stage I to IV NSCLC were enrolled in the study. Free-breathing CT and 4D-CT data sets were acquired at the same simulation session and with the same immobilization. Gross tumor volume (GTV for primary and/or nodal disease was contoured on FBCT (GTV_3D. The 3DCRT plans were obtained, and the patients were treated according to our institution’s standard protocol using FBCT imaging. Gross tumor volume was contoured on 4D-CT for primary and/or nodal disease on all 10 respiratory phases and merged to create internal gross tumor volume (IGTV_4D. Clinical target volume margin was 5 mm in both plans, whereas planning tumor volume (PTV expansion was 1 cm axially and 1.5 cm superior/inferior for FBCT-based plans to incorporate setup errors and an estimate of respiratory-mediated tumor motion vs 8 mm isotropic margin for setup error only in all 4D-CT plans. The 3DCRT plans generated from the FBCT scan were copied on the 4D-CT data set with the same beam parameters. GTV_3D, IGTV_4D, PTV, and dose volume histogram from both data sets were analyzed and compared. Dice coefficient evaluated PTV similarity between FBCT and 4D-CT data sets. Results: In total, 14 of the 15 patients were analyzed. One patient was excluded as there was no measurable GTV. Mean GTV_3D was 115.3 cm 3 and mean IGTV_4D was 152.5 cm 3 ( P = .001. Mean PTV_3D was 530.0 cm 3 and PTV_4D was 499.8 cm 3 ( P = .40. Both gross primary and nodal disease analyzed separately were larger

  12. Gastrointestinal stromal tumors: retrospective analysis of the computer-tomographic aspects.

    Science.gov (United States)

    Lupescu, Ioana G; Grasu, Mugur; Boros, Mirela; Gheorghe, Cristian; Ionescu, Mihnea; Popescu, Irinel; Herlea, Vlad; Georgescu, Serban A

    2007-06-01

    To describe the computer-tomographic (CT) aspects of gastrointestinal stromal tumors (GISTs) in correlation to their histology. The medical records of all patients at our hospital with a histologic diagnosis of GIST between January 2002 and June 2006, and investigated before surgery by CT, were reviewed. Two radiologists with knowledge of the diagnosis reviewed the CT findings. Amongst 15 cases of GISTs, 9 cases involved the stomach and 4 cases the small intestine. Location of the primary tumor could not be determined for 2 of 15 tumors, because of the presence of extensive peritoneal metastases. Most primary tumors were predominantly extraluminal (13 cases) while two were clearly endoluminal. The mean diameter of the primary tumor was 8 cm. The tumor margin was well defined in 12 patients and irregular in 3 cases. Central fluid attenuation was present in 11 tumors, while central gas was seen in two cases. Metastases were seen in 2 cases at presentation and in another 2 patients during follow-up. Spread was exclusive to the liver or peritoneum. Visceral obstruction was absent even in extensive peritoneal metastatic disease. Ascites was an unusual finding. CT plays an important role not only in the detection and the localization but also in the evaluation of the extension and follow-up of theses tumors. Using only CT aspects, we can only suspect the diagnosis to GISTs. Often other soft-tissue tumors with gastrointestinal involvement can mimic GISTs. In all cases histological diagnosis is essential.

  13. Stereological estimates of nuclear volume and other quantitative variables in supratentorial brain tumors. Practical technique and use in prognostic evaluation

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Braendgaard, H; Chistiansen, A O

    1991-01-01

    The use of morphometry and modern stereology in malignancy grading of brain tumors is only poorly investigated. The aim of this study was to present these quantitative methods. A retrospective feasibility study of 46 patients with supratentorial brain tumors was carried out to demonstrate...... the practical technique. The continuous variables were correlated with the subjective, qualitative WHO classification of brain tumors, and the prognostic value of the parameters was assessed. Well differentiated astrocytomas (n = 14) had smaller estimates of the volume-weighted mean nuclear volume and mean...... nuclear profile area, than those of anaplastic astrocytomas (n = 13) (2p = 3.1.10(-3) and 2p = 4.8.10(-3), respectively). No differences were seen between the latter type of tumor and glioblastomas (n = 19). The nuclear index was of the same magnitude in all three tumor types, whereas the mitotic index...

  14. Applications of NLP Techniques to Computer-Assisted Authoring of Test Items for Elementary Chinese

    Science.gov (United States)

    Liu, Chao-Lin; Lin, Jen-Hsiang; Wang, Yu-Chun

    2010-01-01

    The authors report an implemented environment for computer-assisted authoring of test items and provide a brief discussion about the applications of NLP techniques for computer assisted language learning. Test items can serve as a tool for language learners to examine their competence in the target language. The authors apply techniques for…

  15. [Clinical analysis of 12 cases of orthognathic surgery with digital computer-assisted technique].

    Science.gov (United States)

    Tan, Xin-ying; Hu, Min; Liu, Chang-kui; Liu, Hua-wei; Liu, San-xia; Tao, Ye

    2014-06-01

    This study was to investigate the effect of the digital computer-assisted technique in orthognathic surgery. Twelve patients from January 2008 to December 2011 with jaw malformation were treated in our department. With the help of CT and three-dimensional reconstruction technique, 12 patients underwent surgical treatment and the results were evaluated after surgery. Digital computer-assisted technique could clearly show the status of the jaw deformity and assist virtual surgery. After surgery all patients were satisfied with the results. Digital orthognathic surgery can improve the predictability of the surgical procedure, and to facilitate patients' communication, shorten operative time, and reduce patients' pain.

  16. Future Communication, Computing, Control and Management Volume 1

    CERN Document Server

    2012-01-01

    This volume contains revised and extended research articles written by prominent researchers participating in the ICF4C 2011 conference. 2011 International Conference on Future Communication, Computing, Control and Management (ICF4C 2011) has been held on December 16-17, 2011, Phuket, Thailand. Topics covered include intelligent computing, network management, wireless networks, telecommunication, power engineering, control engineering, Signal and Image Processing, Machine Learning, Control Systems and Applications, The book will offer the states of arts of tremendous advances in Computing, Communication, Control, and Management and also serve as an excellent reference work for researchers and graduate students working on Computing, Communication, Control, and Management Research.

  17. Future Communication, Computing, Control and Management Volume 2

    CERN Document Server

    2012-01-01

    This volume contains revised and extended research articles written by prominent researchers participating in the ICF4C 2011 conference. 2011 International Conference on Future Communication, Computing, Control and Management (ICF4C 2011) has been held on December 16-17, 2011, Phuket, Thailand. Topics covered include intelligent computing, network management, wireless networks, telecommunication, power engineering, control engineering, Signal and Image Processing, Machine Learning, Control Systems and Applications, The book will offer the states of arts of tremendous advances in Computing, Communication, Control, and Management and also serve as an excellent reference work for researchers and graduate students working on Computing, Communication, Control, and Management Research.

  18. Future Computing, Communication, Control and Management Volume 2

    CERN Document Server

    2012-01-01

    This volume contains revised and extended research articles written by prominent researchers participating in the ICF4C 2011 conference. 2011 International Conference on Future Communication, Computing, Control and Management (ICF4C 2011) has been held on December 16-17, 2011, Phuket, Thailand. Topics covered include intelligent computing, network management, wireless networks, telecommunication, power engineering, control engineering, Signal and Image Processing, Machine Learning, Control Systems and Applications, The book will offer the states of arts of tremendous advances in Computing, Communication, Control, and Management and also serve as an excellent reference work for researchers and graduate students working on Computing, Communication, Control, and Management Research.

  19. Audiovisual biofeedback guided breath-hold improves lung tumor position reproducibility and volume consistency

    Directory of Open Access Journals (Sweden)

    Danny Lee, PhD

    2017-07-01

    Conclusions: This study demonstrated that audiovisual biofeedback can be used to improve the reproducibility and consistency of breath-hold lung tumor position and volume, respectively. These results may provide a pathway to achieve more accurate lung cancer radiation treatment in addition to improving various medical imaging and treatments by using breath-hold procedures.

  20. Integrating Computer-Assisted Language Learning in Saudi Schools: A Change Model

    Science.gov (United States)

    Alresheed, Saleh; Leask, Marilyn; Raiker, Andrea

    2015-01-01

    Computer-assisted language learning (CALL) technology and pedagogy have gained recognition globally for their success in supporting second language acquisition (SLA). In Saudi Arabia, the government aims to provide most educational institutions with computers and networking for integrating CALL into classrooms. However, the recognition of CALL's…

  1. Preoperative (3-dimensional) computed tomography lung reconstruction before anatomic segmentectomy or lobectomy for stage I non-small cell lung cancer.

    Science.gov (United States)

    Chan, Ernest G; Landreneau, James R; Schuchert, Matthew J; Odell, David D; Gu, Suicheng; Pu, Jiantao; Luketich, James D; Landreneau, Rodney J

    2015-09-01

    Accurate cancer localization and negative resection margins are necessary for successful segmentectomy. In this study, we evaluate a newly developed software package that permits automated segmentation of the pulmonary parenchyma, allowing 3-dimensional assessment of tumor size, location, and estimates of surgical margins. A pilot study using a newly developed 3-dimensional computed tomography analytic software package was performed to retrospectively evaluate preoperative computed tomography images of patients who underwent segmentectomy (n = 36) or lobectomy (n = 15) for stage 1 non-small cell lung cancer. The software accomplishes an automated reconstruction of anatomic pulmonary segments of the lung based on bronchial arborization. Estimates of anticipated surgical margins and pulmonary segmental volume were made on the basis of 3-dimensional reconstruction. Autosegmentation was achieved in 72.7% (32/44) of preoperative computed tomography images with slice thicknesses of 3 mm or less. Reasons for segmentation failure included local severe emphysema or pneumonitis, and lower computed tomography resolution. Tumor segmental localization was achieved in all autosegmented studies. The 3-dimensional computed tomography analysis provided a positive predictive value of 87% in predicting a marginal clearance greater than 1 cm and a 75% positive predictive value in predicting a margin to tumor diameter ratio greater than 1 in relation to the surgical pathology assessment. This preoperative 3-dimensional computed tomography analysis of segmental anatomy can confirm the tumor location within an anatomic segment and aid in predicting surgical margins. This 3-dimensional computed tomography information may assist in the preoperative assessment regarding the suitability of segmentectomy for peripheral lung cancers. Published by Elsevier Inc.

  2. Cone-Beam Computed Tomography (CBCT) Hepatic Arteriography in Chemoembolization for Hepatocellular Carcinoma: Performance Depicting Tumors and Tumor Feeders

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Joon [National Cancer Center, Department of Radiology (Korea, Republic of); Chung, Jin Wook, E-mail: chungjw@snu.ac.kr; Yin, Yong Hu; Kim, Hyo-Cheol; Kim, Young Il; Jae, Hwan Jun; Park, Jae Hyung [Seoul National University College of Medicine, Seoul National University Hospital, Department of Radiology (Korea, Republic of)

    2015-10-15

    PurposeThis study was designed to analyze retrospectively the performance of cone-beam computed tomography (CBCT) hepatic arteriography in depicting tumors and their feeders and to investigate the related determining factors in chemoembolization for hepatocellular carcinoma (HCC).MethodsEighty-six patients with 142 tumors satisfying the imaging diagnosis criteria of HCC were included in this study. The performance of CBCT hepatic arteriography for chemoembolization per tumor and per patient was evaluated using maximum intensity projection images alone (MIP analysis) or MIP combined with multiplanar reformation images (MIP + MPR analysis) regarding the following three aspects: tumor depiction, confidence of tumor feeder detection, and trackability of tumor feeders. Tumor size, tumor enhancement, tumor location, number of feeders, diaphragmatic motion, portal vein enhancement, and hepatic artery to parenchyma enhancement ratio were regarded as potential determining factors.ResultsTumors were depicted in 125 (88.0 %) and 142 tumors (100 %) on MIP and MIP + MPR analysis, respectively. Imaging performances on MIP and MIP + MPR analysis were good enough to perform subsegmental chemoembolization without additional angiographic investigation in 88 (62.0 %) and 128 tumors (90.1 %) on per-tumor basis and in 43 (50 %) and 73 (84.9 %) on per-patient basis, respectively. Significant determining factors for performance in MIP + MPR analysis on per tumor basis were tumor size (p = 0.030), tumor enhancement (0.005), tumor location (p = 0.001), and diaphragmatic motion (p < 0.001).ConclusionsCBCT hepatic arteriography provided sufficient information for subsegmental chemoembolization by depicting tumors and their feeders in the vast majority of patients. Combined analysis of MIP and MPR images was essential to enhance the performance of CBCT hepatic arteriography.

  3. Accuracy of Cytology for Diagnosis of Lipomatous Tumors: Comparison with Magnetic Resonance and Computed Tomography Findings in 175 cases

    International Nuclear Information System (INIS)

    Einarsdottir, H.; Skoog, L.; Soederlund, V.; Bauer, H.C.F.

    2004-01-01

    Purpose: To assess the value of fine-needle aspiration cytology in the diagnostic work-up of lipomatous tumors of the extremities and trunk, and to identify specific radiological features that could aid in the preoperative evaluation. Material and Methods: 175 patients with subfascial lipomatous tumors who had undergone preoperative magnetic resonance imaging or computed tomography and fine-needle aspiration cytology were studied. The percentage of fat within the lesion was visually graded from the images as: none, 1-75%, 75-95%, or 95-100%. The histological and cytological diagnoses were compared and in discordant cases the radiological images were re-reviewed. Results: There was cytological and histological concordance in 96% of lipomas and in 85% of atypical lipomatous tumors (ALT) and liposarcomas. Most discordant cases exhibited 1-75% fat. Radiological review suggested that cytological sampling problems due to tumor heterogeneity were the main cause of diagnostic difficulties. The majority of tumors with less than 75% fat were liposarcomas, and in no liposarcoma was the fat content higher than 75%. Both ALT and lipoma were found in the 95-100% group. Conclusion: Cytology can be highly accurate in the diagnosis of lipomatous tumors, including ALT; however, critical comparison with the radiological findings increases diagnostic security. In tumors with fat content visually assessed as less than 75% of the tumor volume, liposarcoma is the most likely diagnosis and a cytological diagnosis of ALT or lipoma should be questioned. In lesions with 75-95% fat, liposarcoma is unlikely, but FNAC is still indicated for safety. In lesions with 95-100% fat, FNAC is only indicated if the differentiation between lipoma and ALT influences the treatment strategy

  4. Tumor detection using feature extraction

    International Nuclear Information System (INIS)

    Sankar, A.S.; Amudhavalli, N.; Sivakolundu, M.K.

    2008-01-01

    The assistance system for brain tumor detection helps the doctor to analyse the brain tumor in MRI image and help to make decision. The manual detection system takes 3 -5 hours time to analyse the tumor. Doctors are in a position to analyze the tumor faster and make a correct decision with an assistance system

  5. Assisted supervision of a computer aided tele-operation system

    Energy Technology Data Exchange (ETDEWEB)

    Le Bars, H; Gravez, P; Fournier, R

    1994-12-31

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs.

  6. Assisted supervision of a computer aided tele-operation system

    International Nuclear Information System (INIS)

    Le Bars, H.; Gravez, P.; Fournier, R.

    1994-01-01

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs

  7. Center for Advanced Energy Studies: Computer Assisted Virtual Environment (CAVE)

    Data.gov (United States)

    Federal Laboratory Consortium — The laboratory contains a four-walled 3D computer assisted virtual environment - or CAVE TM — that allows scientists and engineers to literally walk into their data...

  8. Volume doubling time and growth rate of renal cell carcinoma determined by helical CT: a single-institution experience

    International Nuclear Information System (INIS)

    Lee, Ji Young; Kim, Chan Kyo; Choi, Dongil; Park, Byung Kwan

    2008-01-01

    The purpose of this study was to retrospectively evaluate the volume doubling time (VDT) and growth rate of renal cell carcinomas (RCC) on a serial computed tomography (CT) scan. Thirty pathologically proven RCCs were reviewed with helical CT. Each tumor underwent at least two CT scans. Tumor volume was determined using an area measuring tool and the summation-of-areas technique. Growth rate was evaluated in terms of diameter and volume changes. VDT and volume growth rate were compared in relation to several factors (initial diameter, initial volume, diameter growth rate, volume growth rate, tumor grade, tumor subtype, sex or age). Mean VDT of RCCs was 505 days. Mean diameter and volume growth rate were 0.59 cm/year and 19.1 cm 3 /year, respectively. For volume and diameter growth rate, tumors ≤4 cm showed lower rates than those >4 cm (P 0.05). Volume growth rate was moderately to strongly positively correlated with initial diameter, initial volume and diameter growth rate (P < 0.05). In conclusion, small RCCs grew at a slow rate both diametrically and volumetrically. More accurate assessment of tumor growth rate and VDT may be helpful to understand the natural history of RCC. (orig.)

  9. Tumor motion and deformation during external radiotherapy of bladder cancer

    International Nuclear Information System (INIS)

    Lotz, Heidi T.; Pos, Floris J.; Hulshof, Maarten C.C.M.; Herk, Marcel van; Lebesque, Joos V.; Duppen, Joop C.; Remeijer, Peter

    2006-01-01

    Purpose: First, to quantify bladder-tumor motion in 3 dimensions during a 4-week to 5-week course of external radiotherapy. Second, to relate the motion to the tumor location on the bladder wall. Third, to extensively evaluate gross tumor volume (GTV) shape and volume changes during the course of the treatment. Methods and Materials: Multiple repeat computed tomography (CT) images were obtained for 21 bladder cancer patients. These scans were matched to the rigid bony anatomy. For each patient, the main direction and magnitude of the tumor movement was determined by use of principle-component analysis. To study GTV shape changes, all GTVs were registered to the GTV in the planning CT scan, and the residual shape errors were determined by measurement of edge variations perpendicular to the median surface. Results: Gross tumor volume translations were largest in cranial-caudal and anterior-posterior direction (SD, 0.1 to ∼0.9 cm). The translations were strongly correlated with the tumor location on the bladder wall. The average value of the local standard deviations of the GTV shape ranged from 0.1 to approximately 0.35 cm. Conclusions: Despite large differences in bladder filling, variations in GTV shape were small compared with variations in GTV position. Geometric uncertainties in the GTV position depended strongly on the tumor location on the bladder wall

  10. Tumor motion and deformation during external radiotherapy of bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lotz, Heidi T [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Department of Radiation Oncology, Academic Medical Centre, University of Amsterdam, Amsterdam (Netherlands); Pos, Floris J [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Hulshof, Maarten C.C.M. [Department of Radiation Oncology, The Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Department of Radiation Oncology, Academic Medical Centre, University of Amsterdam, Amsterdam (Netherlands); Herk, Marcel van [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Lebesque, Joos V [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Duppen, Joop C [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Remeijer, Peter [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)

    2006-04-01

    Purpose: First, to quantify bladder-tumor motion in 3 dimensions during a 4-week to 5-week course of external radiotherapy. Second, to relate the motion to the tumor location on the bladder wall. Third, to extensively evaluate gross tumor volume (GTV) shape and volume changes during the course of the treatment. Methods and Materials: Multiple repeat computed tomography (CT) images were obtained for 21 bladder cancer patients. These scans were matched to the rigid bony anatomy. For each patient, the main direction and magnitude of the tumor movement was determined by use of principle-component analysis. To study GTV shape changes, all GTVs were registered to the GTV in the planning CT scan, and the residual shape errors were determined by measurement of edge variations perpendicular to the median surface. Results: Gross tumor volume translations were largest in cranial-caudal and anterior-posterior direction (SD, 0.1 to {approx}0.9 cm). The translations were strongly correlated with the tumor location on the bladder wall. The average value of the local standard deviations of the GTV shape ranged from 0.1 to approximately 0.35 cm. Conclusions: Despite large differences in bladder filling, variations in GTV shape were small compared with variations in GTV position. Geometric uncertainties in the GTV position depended strongly on the tumor location on the bladder wall.

  11. Preoperative diagnosis of tumors of the brachial plexus by use of computed tomography in three dogs

    International Nuclear Information System (INIS)

    McCarthy, R.J.; Feeney, D.A.; Lipowitz, A.J.

    1993-01-01

    Three dogs with forelimb lameness of 3 months' to 1 year's duration were examined by computed tomography and determined to have a tumor of the brachial plexus. In each case, the clinician had been unable to determine the cause of lameness by other means, and in 2 dogs, surgery had been performed on the affected limb for unrelated conditions prior to diagnosis of the tumor. Computed tomography was performed by use of a third-generation scanner, with dogs under general anesthesia and positioned in dorsal recumbency. Intravenous contrast enhancement with iodinated contrast material was used to help differentiate vascular structures, and a 5-mm scanning width allowed detection of small tumors. In all dogs, approximate tumor location in the transverse plane, invasiveness, and relationship to surrounding structures compared favorably between computed tomographic images and surgical findings

  12. Computer-assisted power plant management

    International Nuclear Information System (INIS)

    Boettcher, D.

    1990-01-01

    Operating a power plant and keeping it operational is ensured by a multiplicity of technical management subtasks which are cross referenced and based on an extensive inventory of descriptive and operational plant data. These data stocks are still registered in an isolated mode and managed and updated manually. This is a labor intensive, error prone procedure. In this situation, the introduction of a computer-assisted plant management system, whose core is a data-base of assured quality common to all activities, and which contains standardized processing aids fully planned for the subtasks occurring in the plant, is likely to achieve a considerable improvement in the quality of plant management and to relieve the staff of administrative activities. (orig.) [de

  13. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    Science.gov (United States)

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  14. Mid-term survival analysis of closed wedge high tibial osteotomy: A comparative study of computer-assisted and conventional techniques.

    Science.gov (United States)

    Bae, Dae Kyung; Song, Sang Jun; Kim, Kang Il; Hur, Dong; Jeong, Ho Yeon

    2016-03-01

    The purpose of the present study was to compare the clinical and radiographic results and survival rates between computer-assisted and conventional closing wedge high tibial osteotomies (HTOs). Data from a consecutive cohort comprised of 75 computer-assisted HTOs and 75 conventional HTOs were retrospectively reviewed. The Knee Society knee and function scores, Hospital for Special Surgery (HSS) score and femorotibial angle (FTA) were compared between the two groups. Survival rates were also compared with procedure failure. The knee and function scores at one year postoperatively were slightly better in the computer-assisted group than those in conventional group (90.1 vs. 86.1) (82.0 vs. 76.0). The HSS scores at one year postoperatively were slightly better for the computer-assisted HTOs than those of conventional HTOs (89.5 vs. 81.8). The inlier of the postoperative FTA was wider in the computer-assisted group than that in the conventional HTO group (88.0% vs. 58.7%), and mean postoperative FTA was greater in the computer-assisted group that in the conventional HTO group (valgus 9.0° vs. valgus 7.6°, pclinical and radiographic results were better in the computer-assisted group that those in the conventional HTO group. Mid-term survival rates did not differ between computer-assisted and conventional HTOs. A comparative analysis of longer-term survival rate is required to demonstrate the long-term benefit of computer-assisted HTO. III. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Antibody directed against human YKL-40 increases tumor volume in a human melanoma xenograft model in scid mice

    DEFF Research Database (Denmark)

    Salamon, Johannes; Hoffmann, Tatjana; Elies, Eva

    2014-01-01

    were treated with intraperitoneal injections of anti-YKL-40, isoptype control or PBS. Non-YKL-40 expressing human pancreatic carcinoma cell line PaCa 5061 served as additional control. MR imaging was used for evaluation of tumor growth. Two days after the first injections of anti-YKL-40, tumor volume...... had increased significantly compared with controls, whereas no effects were observed for control tumors from PaCa 5061 cells lacking YKL-40 expression. After 18 days, mean tumor size of the mice receiving repeated anti-YKL-40 injections was 1.82 g, >4 times higher than mean tumor size of the controls...

  16. Two-Cloud-Servers-Assisted Secure Outsourcing Multiparty Computation

    Directory of Open Access Journals (Sweden)

    Yi Sun

    2014-01-01

    Full Text Available We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users’ public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function.

  17. Measurement of normal ocular volume by the use of computed ...

    African Journals Online (AJOL)

    Background: Reduction or increase in ocular volume may indicate ocular pathology. Unfortunately the reference values utilized for ocular volume had been that of non-Africans. It is therefore pertinent to have a reference value of normal for Africans. Objective: To document the computer tomography (CT) scan measured ...

  18. Computer-Assisted Foreign Language Teaching and Learning: Technological Advances

    Science.gov (United States)

    Zou, Bin; Xing, Minjie; Wang, Yuping; Sun, Mingyu; Xiang, Catherine H.

    2013-01-01

    Computer-Assisted Foreign Language Teaching and Learning: Technological Advances highlights new research and an original framework that brings together foreign language teaching, experiments and testing practices that utilize the most recent and widely used e-learning resources. This comprehensive collection of research will offer linguistic…

  19. The Effects of Computer-Assisted Feedback Strategies in Technology Education: A Comparison of Learning Outcomes

    Science.gov (United States)

    Adams, Ruifang Hope; Strickland, Jane

    2012-01-01

    This study investigated the effects of computer-assisted feedback strategies that have been utilized by university students in a technology education curriculum. Specifically, the study examined the effectiveness of the computer-assisted feedback strategy "Knowledge of Response feedback" (KOR), and the "Knowledge of Correct Responses feedback"…

  20. Computer-assisted spectral design and synthesis

    Science.gov (United States)

    Vadakkumpadan, Fijoy; Wang, Qiqi; Sun, Yinlong

    2005-01-01

    In this paper, we propose a computer-assisted approach for spectral design and synthesis. This approach starts with some initial spectrum, modifies it interactively, evaluates the change, and decides the optimal spectrum. Given a requested change as function of wavelength, we model the change function using a Gaussian function. When there is the metameric constraint, from the Gaussian function of request change, we propose a method to generate the change function such that the result spectrum has the same color as the initial spectrum. We have tested the proposed method with different initial spectra and change functions, and implemented an interactive graphics environment for spectral design and synthesis. The proposed approach and graphics implementation for spectral design and synthesis can be helpful for a number of applications such as lighting of building interiors, textile coloration, and pigment development of automobile paints, and spectral computer graphics.

  1. Three-Dimensional Computer-Assisted Two-Layer Elastic Models of the Face.

    Science.gov (United States)

    Ueda, Koichi; Shigemura, Yuka; Otsuki, Yuki; Fuse, Asuka; Mitsuno, Daisuke

    2017-11-01

    To make three-dimensional computer-assisted elastic models for the face, we decided on five requirements: (1) an elastic texture like skin and subcutaneous tissue; (2) the ability to take pen marking for incisions; (3) the ability to be cut with a surgical knife; (4) the ability to keep stitches in place for a long time; and (5) a layered structure. After testing many elastic solvents, we have made realistic three-dimensional computer-assisted two-layer elastic models of the face and cleft lip from the computed tomographic and magnetic resonance imaging stereolithographic data. The surface layer is made of polyurethane and the inner layer is silicone. Using this elastic model, we taught residents and young doctors how to make several typical local flaps and to perform cheiloplasty. They could experience realistic simulated surgery and understand three-dimensional movement of the flaps.

  2. Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems

    Science.gov (United States)

    2017-04-13

    AFRL-AFOSR-UK-TR-2017-0029 Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems ...2012, “ Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems .” 2. The objective...2012 - 01/25/2015 4. TITLE AND SUBTITLE Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous

  3. The use of computer graphics to assist in-reactor operations

    International Nuclear Information System (INIS)

    Smith, A.L.

    1995-01-01

    A number of complex inspection and repair tasks have been carried out inside Nuclear Electric's gas cooled reactors using multi-link manipulators. The paper describes how computer graphics are integrated into the manipulator system and perform a key role during many phases of a project. Graphics simulation is used to assist with conceptual design, detailed path planning, rehearsals, quality assurance, demonstrations and, critically, as an on-line tool to assist the real-time operation of the equipment whilst performing complex in-reactor tasks. The techniques used are illustrated by recent examples of use to assist the inspection and repair of in-reactor components. (Author)

  4. Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by 18F-FDG-microPET or external caliper

    DEFF Research Database (Denmark)

    Jensen, Mette Munk; Jørgensen, Jesper Tranekjaer; Binderup, Tina

    2008-01-01

    BACKGROUND: In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate...... (n = 20) was determined in vivo by external caliper, microCT and 18F-FDG-PET and subsequently reference volume was determined ex vivo. Intra-observer reproducibility of the microCT and caliper methods were determined by acquiring 10 repeated volume measurements. Volumes of a group of tumors (n = 10......) were determined independently by two observers to assess inter-observer variation. RESULTS: Tumor volume measured by microCT, PET and caliper all correlated with reference volume. No significant bias of microCT measurements compared with the reference was found, whereas both PET and caliper had...

  5. Hepatic volumetry with PhotoShop in personal computer.

    Science.gov (United States)

    Lu, Yi; Wu, Zheng; Liu, Chang; Wang, Hao-Hua

    2004-02-01

    Convenient way to clarify liver volume or tumor volume in the liver is eagerly demanded by hepatobiliary surgeons, for so many aspects of clinical work need to know the liver volumetry. At present, some methods have been used to measure the liver volumetry, such as computed tomography (CT) scans, three-dimensional ultrasound volumetric system([1]) and 3-dimensional sonography([2,3]) et al. But enough volumetric information was failed to obtain by surgeons and a new way of measuring the liver volumetry that can be operated by themselves is exigent. Whereas we devise a new method of using PhotoShop in personal computer to measure the liver volumetry. A piece of whole CT film was transformed to a high quality digitized image by digital camera or scanner and then the digitized image was conducted as JPEG file into personal computer. The JPEG image file of CT film was opened by PhotoShop. Determining the edge of interested areas, and the data of pixel values of the interested areas divided by 1 cm2 pixel value will produce the actual area with the unit of square centimeter. If section thickness of CT scan is 1 cm, the sum of the areas of the liver or tumor in all sections naturally is the volume of the liver or tumor. Comparison of 10 hepatic volumes gained by this method and those gained by the GE Prospeed CT set showed a good relativity between the two groups. The volumes of three right lobes were calculated by this method before lobectomy and their real volumes were obtained postoperatively by a volumenometer. Their variation was limited to 5%. Hepatic volume obtained by PhotoShop is reliable. This method can be used to measure hepatic volume perfectly to meet clinical demand, and many parameters such as liver resection rate, graft volume can be achieved. The disadvantage of this method is the step of copying the pixel value from PhotoShop to Microsoft Excel.

  6. Public Computer Assisted Learning Facilities for Children with Visual Impairment: Universal Design for Inclusive Learning

    Science.gov (United States)

    Siu, Kin Wai Michael; Lam, Mei Seung

    2012-01-01

    Although computer assisted learning (CAL) is becoming increasingly popular, people with visual impairment face greater difficulty in accessing computer-assisted learning facilities. This is primarily because most of the current CAL facilities are not visually impaired friendly. People with visual impairment also do not normally have access to…

  7. Radiologic measurement of extraocular muscle volumes in patients with Graves' orbitopathy: a review and guideline.

    Science.gov (United States)

    Bijlsma, Ward R; Mourits, Maarten Ph

    2006-06-01

    To evaluate and compare techniques for extraocular muscle (EOM) volume measurement and to provide guidelines for future measurements. Systematic review. Existing techniques used to measure extraocular muscle volumes on radiologic scans can be divided into manual outlining, computer assisted and automated segmentation. Both computed tomography (CT) and magnetic resonance (MR) image datasets can be used. On CT scans, one best measures muscle volume using region grow segmentation, accepting an overestimation of true volume by inevitable inclusion of non-muscular tissue. On high resolution MRI scans, single muscles can be outlined manually, but measurements include only part of the muscle due to poor tissue contrast at the orbital apex. Measurement errors can be reduced 3.5% by exact horizontal repositioning. A measured volume change of at least 6-17% is required to demonstrate a significant difference. Currently the best choice for EOM volume measurements on CT images is computer assisted grey value segmentation and on MRI images is manual outlining of individual muscles. Because of the time required and the complexity of the measurements, present EOM volume measurement is as yet only suitable for research purposes.

  8. Applying Integrated Computer Assisted Media (ICAM in Teaching Vocabulary

    Directory of Open Access Journals (Sweden)

    Opick Dwi Indah

    2015-02-01

    Full Text Available The objective of this research was to find out whether the use of integrated computer assisted media (ICAM is effective to improve the vocabulary achievement of the second semester students of Cokroaminoto Palopo University. The population of this research was the second semester students of English department of Cokroaminoto Palopo University in academic year 2013/2014. The samples of this research were 60 students and they were placed into two groups: experimental and control group where each group consisted of 30 students. This research used cluster random sampling technique. The research data was collected by applying vocabulary test and it was analyzed by using descriptive and inferential statistics. The result of this research was integrated computer assisted media (ICAM can improve vocabulary achievement of the students of English department of Cokroaminoto Palopo University. It can be concluded that the use of ICAM in the teaching vocabulary is effective to be implemented in improving the students’ vocabulary achievement.

  9. Enrichment of circulating tumor cells from a large blood volume using leukapheresis and elutriation: proof of concept.

    Science.gov (United States)

    Eifler, Robert L; Lind, Judith; Falkenhagen, Dieter; Weber, Viktoria; Fischer, Michael B; Zeillinger, Robert

    2011-03-01

    The aim of this study was to determine the applicability of a sequential process using leukapheresis, elutriation, and fluorescence-activated cell sorting (FACS) to enrich and isolate circulating tumor cells from a large blood volume to allow further molecular analysis. Mononuclear cells were collected from 10 L of blood by leukapheresis, to which carboxyfluorescein succinimidyl ester prelabeled CaOV-3 tumor cells were spiked at a ratio of 26 to 10⁶ leukocytes. Elutriation separated the spiked leukapheresates primarily by cell size into distinct fractions, and leukocytes and tumor cells, characterized as carboxyfluorescein succinimidyl ester positive, EpCAM positive and CD45 negative events, were quantified by flow cytometry. Tumor cells were isolated from the last fraction using FACS or anti-EpCAM coupled immunomagnetic beads, and their recovery and purity determined by fluorescent microscopy and real-time PCR. Leukapheresis collected 13.5 x 10⁹ mononuclear cells with 87% efficiency. In total, 53 to 78% of spiked tumor cells were pre-enriched in the last elutriation fraction among 1.6 x 10⁹ monocytes. Flow cytometry predicted a circulating tumor cell purity of ~90% giving an enrichment of 100,000-fold following leukapheresis, elutriation, and FACS, where CaOV-3 cells were identified as EpCAM positive and CD45 negative events. FACS confirmed this purity. Alternatively, immunomagnetic bead adsorption recovered 10% of tumor cells with a median purity of 3.5%. This proof of concept study demonstrated that elutriation and FACS following leukapheresis are able to enrich and isolate tumor cells from a large blood volume for molecular characterization. Copyright © 2010 International Clinical Cytometry Society.

  10. Prognostic role of tumor volume for radiotherapy outcome in patient with T2 laryngeal cancer

    International Nuclear Information System (INIS)

    Rutkowski, T.; Wygoda, A.; Skladowski, K.; Rutkowski, R.; Maciejewski, B.; Hejduk, B.; Kolosza, Z.

    2013-01-01

    Background and purpose: Tumor volume (TV) is recognized as a prognostic factor of treatment outcome for head and neck tumors but is not routinely included in the treatment decision-making process. The purpose of the study was to define its prognostic role for patients with T2 laryngeal cancer. Material and methods: TV of 160 patients who underwent RT between 2002 and 2006 for T2 laryngeal squamous cell carcinoma were reviewed. The tumor was located in the glottis and epiglottis in 82 (51 %) and 78 (49 %) patients, respectively. TV was manually contoured on pretreatment, planning, contrast-enhanced CT scans and the volumetric measurement (cm 3 ) was calculated by the volume algorithm. Results: The median TV value was 2.01 cm 3 (range 0.15-21.68 cm 3 ). The median TV was significantly lower in patients with glottic tumors (p < 0.0001), N0 (p < 0.001), or well histopatologically differentiated tumors (p = 0.01). A significant correlation between TV, hemoglobin concentration (p < 0.01), and total dose (TD; p < 0.001) was observed. On univariate analyses, TV influenced local control (LC; p = 0.02) and overall survival (OS, p < 0.001). On multivariate analysis, both age (HR 1.038, p = 0.03) and TV (HR = 1.075, p = 0.01) remained significantly related to LC and OS (age: HR 1.038, p = 0.005; TV: HR 1.097, p = 0.0001). Conclusion: Large TV worsen prognosis of patients with T2 laryngeal cancer. A large TV is more common for supraglottic, poorly differentiated tumors and may suggest higher risk of nodal spread. The routine estimation of TV prior to therapy may be essential in order to select the best treatment option for patients with T2 laryngeal cancer. (orig.)

  11. Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Ganesh, Tharmar; Rath, Goura K.; Julka, Pramod K.; Sridhar, Pappiah S.; Joshi, Rakesh C.; Thulkar, Sanjay

    2009-01-01

    The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume 25 cc

  12. The Impact of Computer-Assisted Instruction on Secondary School ...

    African Journals Online (AJOL)

    This research, carried out in Manicaland Province in Zimbabwe, aimed to investigate the impact of computer-assisted instruction on students' performance in Geography. The equivalent group research design which included a pre-test post-test control group design was used. Respondents to interviews and pre-test and ...

  13. Computer assisted radionuclide angiography to confirm reversible ischemic cerebral dysfunction

    International Nuclear Information System (INIS)

    Buell, U.; Lanksch, W.; Tosch, U.; Kleinhans, E.; Steinhoff, H.

    1982-01-01

    Computer assisted radionuclide angiography (CARNA) was employed in patients with transient ischemic attack (TIA) or prolonged reversible ischemic neurologic deficit (PRIND) to establish the sensitivity of CARNA in detecting and quantifying changes of cerebral perfusion in such selected patients. Moreover, results of CARNA were compared with findings of cranial radiographic angiography (RGA) to obtain data on combined sensitivities of these methods. CARNA may be the preferred noninvasive procedure employed because it detects and quantifies the vascular supply disorder in patients with TIA and PRIND. If no computer assistance is used to evaluate cranial radionuclide angiography, results are considerable less accurate. Specifity of CARNA is 84.6%. If CARNA is negative (25.2% in TIA; 12.7% in PRIND), a further method must be employed to confirm the cranial vascular origin of the attack. This may be RGA in TIA and transmission computed axial tomography (T-CAT) T-CAT in PRIND. This diagnos - tic sequence lead to 92.4% true positive in TIA and to 93.2% true positives in PRIND

  14. Agent assisted interactive algorithm for computationally demanding multiobjective optimization problems

    OpenAIRE

    Ojalehto, Vesa; Podkopaev, Dmitry; Miettinen, Kaisa

    2015-01-01

    We generalize the applicability of interactive methods for solving computationally demanding, that is, time-consuming, multiobjective optimization problems. For this purpose we propose a new agent assisted interactive algorithm. It employs a computationally inexpensive surrogate problem and four different agents that intelligently update the surrogate based on the preferences specified by a decision maker. In this way, we decrease the waiting times imposed on the decision maker du...

  15. Prognostic value of defining the systemic tumor volume with FDG-PET in diffuse large b cell lymphoma

    International Nuclear Information System (INIS)

    Byun, Byung Hyun; Lim, Sang Moo; Cheon, Gi Jeong; Choi, Chang Woon; Kang, Hye Jin; Na, Im Il; Ryoo, Baek Yeol; Yang, Sung Hyun

    2007-01-01

    We measured the systemic tumor volume using FDG-PET in patients with diffuse large B cell lymphoma (DLBL). We also investigated its prognostic role, and compared it with that of other prognostic factors. FDG PET was performed in 38 newly diagnosed DLBL patients (20 men, 18 women, age 55.715.1 years) at pre-treatment of chemotherapy. Clinical staging of lymphoma was evaluated by Ann Arbor system. On each FDG PET scan, we acquired volume of interest (VOl) at the cut-off value of SUV=2.5 in every measurable tumor by the automatic edge detection software. According to the VOI, we measured the metabolic volume and mean SUV, and estimated volume-activity indexes (SUV Vol) as mean SUV times metabolic volume. And then, we calculated the summed metabolic volume (VOLsum) and summed SUV Vol (SUV Volsum) in every FDG PET scan. Maximum SUV of involved lesion (SUVmax) was also acquired on each FDG PET scan. Time to treatment failure (TTF) was compared among VOLsum (median), SUV Volsum (median), SUVmax (median), clinical stage, gender, age, LDH, and performance status-assigned response designations by Kaplan-Meier survival analysis. Initial stages of DLBL patients were stage I in 4, II in 14, III in 15, and IV in 4 by Ann Arbor system. Median follow up period was 15.5months, and estimated mean TTF was 22.3 months. Univariate analysis demonstrated that TTF is statistically significantly reduced in those with high VOLsum (>215.1cm2, p=0.004), high SUV Volsum (>1577.5, p=0.003), and increased LDH (p=0.036). TTF did not correlate with SUVmax (p=0.571), clinical stage (p=0.194), gender (p=0.549), and age (p=0.128), and performance status =2 (p=0.074). Multivariate analysis using VOLsum, SUV Volsum, LDH, and performance status demonstrated no statistically significant predictor of TTF (p>0.05). Systemic tumor volume measurement using FDG-PET is suggestive to be the significant prognostic factor in patients with DLBL

  16. Surface Modeling, Solid Modeling and Finite Element Modeling. Analysis Capabilities of Computer-Assisted Design and Manufacturing Systems.

    Science.gov (United States)

    Nee, John G.; Kare, Audhut P.

    1987-01-01

    Explores several concepts in computer assisted design/computer assisted manufacturing (CAD/CAM). Defines, evaluates, reviews and compares advanced computer-aided geometric modeling and analysis techniques. Presents the results of a survey to establish the capabilities of minicomputer based-systems with the CAD/CAM packages evaluated. (CW)

  17. Interactive computer-assisted instruction in acid-base physiology for mobile computer platforms.

    Science.gov (United States)

    Longmuir, Kenneth J

    2014-03-01

    In this project, the traditional lecture hall presentation of acid-base physiology in the first-year medical school curriculum was replaced by interactive, computer-assisted instruction designed primarily for the iPad and other mobile computer platforms. Three learning modules were developed, each with ∼20 screens of information, on the subjects of the CO2-bicarbonate buffer system, other body buffer systems, and acid-base disorders. Five clinical case modules were also developed. For the learning modules, the interactive, active learning activities were primarily step-by-step learner control of explanations of complex physiological concepts, usually presented graphically. For the clinical cases, the active learning activities were primarily question-and-answer exercises that related clinical findings to the relevant basic science concepts. The student response was remarkably positive, with the interactive, active learning aspect of the instruction cited as the most important feature. Also, students cited the self-paced instruction, extensive use of interactive graphics, and side-by-side presentation of text and graphics as positive features. Most students reported that it took less time to study the subject matter with this online instruction compared with subject matter presented in the lecture hall. However, the approach to learning was highly examination driven, with most students delaying the study of the subject matter until a few days before the scheduled examination. Wider implementation of active learning computer-assisted instruction will require that instructors present subject matter interactively, that students fully embrace the responsibilities of independent learning, and that institutional administrations measure instructional effort by criteria other than scheduled hours of instruction.

  18. Pre-Service Teachers' Uses of and Barriers from Adopting Computer-Assisted Language Learning (CALL) Programs

    Science.gov (United States)

    Samani, Ebrahim; Baki, Roselan; Razali, Abu Bakar

    2014-01-01

    Success in implementation of computer-assisted language learning (CALL) programs depends on the teachers' understanding of the roles of CALL programs in education. Consequently, it is also important to understand the barriers teachers face in the use of computer-assisted language learning (CALL) programs. The current study was conducted on 14…

  19. Decision Trees Predicting Tumor Shrinkage for Head and Neck Cancer: Implications for Adaptive Radiotherapy.

    Science.gov (United States)

    Surucu, Murat; Shah, Karan K; Mescioglu, Ibrahim; Roeske, John C; Small, William; Choi, Mehee; Emami, Bahman

    2016-02-01

    To develop decision trees predicting for tumor volume reduction in patients with head and neck (H&N) cancer using pretreatment clinical and pathological parameters. Forty-eight patients treated with definitive concurrent chemoradiotherapy for squamous cell carcinoma of the nasopharynx, oropharynx, oral cavity, or hypopharynx were retrospectively analyzed. These patients were rescanned at a median dose of 37.8 Gy and replanned to account for anatomical changes. The percentages of gross tumor volume (GTV) change from initial to rescan computed tomography (CT; %GTVΔ) were calculated. Two decision trees were generated to correlate %GTVΔ in primary and nodal volumes with 14 characteristics including age, gender, Karnofsky performance status (KPS), site, human papilloma virus (HPV) status, tumor grade, primary tumor growth pattern (endophytic/exophytic), tumor/nodal/group stages, chemotherapy regimen, and primary, nodal, and total GTV volumes in the initial CT scan. The C4.5 Decision Tree induction algorithm was implemented. The median %GTVΔ for primary, nodal, and total GTVs was 26.8%, 43.0%, and 31.2%, respectively. Type of chemotherapy, age, primary tumor growth pattern, site, KPS, and HPV status were the most predictive parameters for primary %GTVΔ decision tree, whereas for nodal %GTVΔ, KPS, site, age, primary tumor growth pattern, initial primary GTV, and total GTV volumes were predictive. Both decision trees had an accuracy of 88%. There can be significant changes in primary and nodal tumor volumes during the course of H&N chemoradiotherapy. Considering the proposed decision trees, radiation oncologists can select patients predicted to have high %GTVΔ, who would theoretically gain the most benefit from adaptive radiotherapy, in order to better use limited clinical resources. © The Author(s) 2015.

  20. Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

    International Nuclear Information System (INIS)

    Knybel, Lukas; Cvek, Jakub; Molenda, Lukas; Stieberova, Natalie; Feltl, David

    2016-01-01

    Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P 15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P 3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe tumors; higher interfraction amplitude variability indicated tumors in contact

  1. Clinical significance of measurement of hepatic volume by computed tomography

    International Nuclear Information System (INIS)

    Sato, Hiroyuki; Matsuda, Yoshiro; Takada, Akira

    1984-01-01

    Hepatic volumes were measured by computed tomography (CT) in 91 patients with chronic liver diseases. Mean hepatic volume in alcoholic liver disease was significantly larger than that in non-alcoholic liver disease. Hepatic volumes in the majority of decompensated liver cirrhosis were significantly smaller than those of compensated liver cirrhosis. In liver cirrhosis, significant correlations between hepatic volume and various hepatic tests which reflect the total functioning hepatic cell masses were found. Combinations of hepatic volume with ICG maximum removal rate and with serum cholinesterase activity were most useful for the assessment of prognosis in liver cirrhosis. These results indicated that estimation of hepatic volume by CT is useful for analysis of pathophysiology and prognosis of chronic liver diseases, and for diagnosis of alcoholic liver diseases. (author)

  2. Computer-assisted training experiment used in the field of thermal energy production (EDF)

    International Nuclear Information System (INIS)

    Felgines, R.

    1982-01-01

    In 1981, the EDF carried out an experiment with computer-assisted training (EAO). This new approach, which continued until June 1982, involved about 700 employees all of whom operated nuclear power stations. The different stages of this experiment and the lessons which can be drawn from it are given the lessons were of a positive nature and make it possible to envisage complete coverage of all nuclear power stations by computer-assisted training within a very short space of time [fr

  3. [Computer-assisted navigation in orthognathic surgery. Application to Le Fort I osteotomy.

    Science.gov (United States)

    Benassarou, M; Benassarou, A; Meyer, C

    2013-08-05

    Computer-assisted navigation is a tool that allows the surgeon to reach intraoperatively a previously defined target. This technique can be applied to the positioning of bone fragments in orthognathic surgery. It is not used routinely yet because there are no specifically dedicated systems available on the market for this kind of surgery. The goal of our study was to describe the various systems that could be used in orthognathic surgery and to report our experience of computer-assisted surgery in the positioning of the maxilla during maxillomandibular osteotomies. Copyright © 2013. Published by Elsevier Masson SAS.

  4. SU-F-T-538: CyberKnife with MLC for Treatment of Large Volume Tumors: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Bichay, T; Mayville, A [Mercy Health, Saint Mary’s, Grand Rapids, MI (United States)

    2016-06-15

    Purpose: CyberKnife is a well-documented modality for SRS and SBRT treatments. Typical tumors are small and 1–5 fractions are usually used. We determined the feasibility of using CyberKnife, with an InCise multileaf collimator option, for larger tumors undergoing standard dose and fractionation. The intent was to understand the limitation of using this modality for other external beam radiation treatments. Methods: Five tumors from different anatomical sites with volumes from 127.8 cc to 1,320.5 cc were contoured and planned on a Multiplan V5.1 workstation. The target average diameter ranged from 7 cm to 13 cm. The dose fractionation was 1.8–2.0 Gy/fraction and 25–45 fractions for total doses of 45–81 Gy. The sites planned were: pancreas, head and neck, prostate, anal, and esophagus. The plans were optimized to meet conventional dose constraints based on various RTOG protocols for conventional fractionation. Results: The Multiplan treatment planning system successfully generated clinically acceptable plans for all sites studied. The resulting dose distributions achieved reasonable target coverage, all greater than 95%, and satisfactory normal tissue sparing. Treatment times ranged from 9 minutes to 38 minutes, the longest being a head and neck plan with dual targets receiving different doses and with multiple adjacent critical structures. Conclusion: CyberKnife, with the InCise multileaf collimation option, can achieve acceptable dose distributions in large volume tumors treated with conventional dose and fractionation. Although treatment times are greater than conventional accelerator time; target coverage and dose to critical structures can be kept within a clinically acceptable range. While time limitations exist, when necessary CyberKnife can provide an alternative to traditional treatment modalities for large volume tumors.

  5. The role of computed tomography in the localization of adrenal cortex tumors

    International Nuclear Information System (INIS)

    Baranowska, B.; Misiorowski, W.; Pacho, R.; Wysocki, M.; Kobuszewska, M.; Zgliczynski, S.; Medical Center of Postgraduate Education, Warsaw

    1982-01-01

    The aim of this study was to evaluate the usefulness of computed tomography in the localisation of adrenal tumors producing aldosterone and cortisol. One case each of Conn's and Cushing's syndrome are described. The diagnosis of Conn's syndrome was established by demonstrating an elevated plasma aldosterone level 'at rest' and its decrease after stimulation, the absence of plasma renin activity and a lowered plasma potassium level. The diagnosis of Cushing's syndrome due to adrenal adenoma was established by demonstrating the typical clinical features, an abnormal diurnal rhythm of cortisol and ACTH secretion and an increased urine excretion of 17-OHCS without suppression by large doses of dexamethasone. The localisation and the size of the tumors as determined by computed tomography were confirmed during surgery. (orig.) [de

  6. Computer-assisted modeling: Contributions of computational approaches to elucidating macromolecular structure and function: Final report

    International Nuclear Information System (INIS)

    Walton, S.

    1987-01-01

    The Committee, asked to provide an assessment of computer-assisted modeling of molecular structure, has highlighted the signal successes and the significant limitations for a broad panoply of technologies and has projected plausible paths of development over the next decade. As with any assessment of such scope, differing opinions about present or future prospects were expressed. The conclusions and recommendations, however, represent a consensus of our views of the present status of computational efforts in this field

  7. Advances in Reactor Physics, Mathematics and Computation. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    These proceedings of the international topical meeting on advances in reactor physics, mathematics and computation, volume one, are divided into 6 sessions bearing on: - session 1: Advances in computational methods including utilization of parallel processing and vectorization (7 conferences) - session 2: Fast, epithermal, reactor physics, calculation, versus measurements (9 conferences) - session 3: New fast and thermal reactor designs (9 conferences) - session 4: Thermal radiation and charged particles transport (7 conferences) - session 5: Super computers (7 conferences) - session 6: Thermal reactor design, validation and operating experience (8 conferences).

  8. Automated lung tumor segmentation for whole body PET volume based on novel downhill region growing

    Science.gov (United States)

    Ballangan, Cherry; Wang, Xiuying; Eberl, Stefan; Fulham, Michael; Feng, Dagan

    2010-03-01

    We propose an automated lung tumor segmentation method for whole body PET images based on a novel downhill region growing (DRG) technique, which regards homogeneous tumor hotspots as 3D monotonically decreasing functions. The method has three major steps: thoracic slice extraction with K-means clustering of the slice features; hotspot segmentation with DRG; and decision tree analysis based hotspot classification. To overcome the common problem of leakage into adjacent hotspots in automated lung tumor segmentation, DRG employs the tumors' SUV monotonicity features. DRG also uses gradient magnitude of tumors' SUV to improve tumor boundary definition. We used 14 PET volumes from patients with primary NSCLC for validation. The thoracic region extraction step achieved good and consistent results for all patients despite marked differences in size and shape of the lungs and the presence of large tumors. The DRG technique was able to avoid the problem of leakage into adjacent hotspots and produced a volumetric overlap fraction of 0.61 +/- 0.13 which outperformed four other methods where the overlap fraction varied from 0.40 +/- 0.24 to 0.59 +/- 0.14. Of the 18 tumors in 14 NSCLC studies, 15 lesions were classified correctly, 2 were false negative and 15 were false positive.

  9. A Unique Case of Diffuse Metastatic Neuroendocrine Cancer with Subcutaneous Nodules on 18F-Fluorodeoxyglucose Positron Emission Tomography/Computer Assisted Tomography

    International Nuclear Information System (INIS)

    Johnston, Mickaila J.; Sachedina, Archana; McDonald, James E.

    2015-01-01

    Neuroendocrine tumors (NETs) account for 8–10% of cases of carcinomas of unknown primary. Most of these cases are poorly differentiated with metastatic disease at the time of diagnosis. However, cutaneous metastatic presentation is rare. We present an interesting case of a 74-year-old woman presenting with cutaneous metastatic involvement from high grade poorly differentiated NET of unknown origin. She was referred to us with a diagnosis of lymphoma. 18 F-fluorodeoxyglucose positron emission tomography/computer assisted tomography imaging at our institution offered a differential diagnosis, including neuroendocrine cancer. Repeat skin lesion biopsy demonstrated “non-Merkel cell” carcinoma, favoring metastatic high-grade neuroendocrine carcinoma

  10. Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

    Science.gov (United States)

    Court, Laurence E.; Kisling, Kelly; McCarroll, Rachel; Zhang, Lifei; Yang, Jinzhong; Simonds, Hannah; du Toit, Monique; Trauernicht, Chris; Burger, Hester; Parkes, Jeannette; Mejia, Mike; Bojador, Maureen; Balter, Peter; Branco, Daniela; Steinmann, Angela; Baltz, Garrett; Gay, Skylar; Anderson, Brian; Cardenas, Carlos; Jhingran, Anuja; Shaitelman, Simona; Bogler, Oliver; Schmeller, Kathleen; Followill, David; Howell, Rebecca; Nelson, Christopher; Peterson, Christine; Beadle, Beth

    2018-01-01

    The Radiation Planning Assistant (RPA) is a system developed for the fully automated creation of radiotherapy treatment plans, including volume-modulated arc therapy (VMAT) plans for patients with head/neck cancer and 4-field box plans for patients with cervical cancer. It is a combination of specially developed in-house software that uses an application programming interface to communicate with a commercial radiotherapy treatment planning system. It also interfaces with a commercial secondary dose verification software. The necessary inputs to the system are a Treatment Plan Order, approved by the radiation oncologist, and a simulation computed tomography (CT) image, approved by the radiographer. The RPA then generates a complete radiotherapy treatment plan. For the cervical cancer treatment plans, no additional user intervention is necessary until the plan is complete. For head/neck treatment plans, after the normal tissue and some of the target structures are automatically delineated on the CT image, the radiation oncologist must review the contours, making edits if necessary. They also delineate the gross tumor volume. The RPA then completes the treatment planning process, creating a VMAT plan. Finally, the completed plan must be reviewed by qualified clinical staff. PMID:29708544

  11. Malignant tumors of the nasal cavity: computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Souza, Ricardo Pires de; Paes Junior, Ademar Jose de Oliveira; Gonzalez, Fabio Mota; Cordeiro, Flamarion de Barros; Yamashiro, Ilka; Lenh, Carlos Neutzling; Rapoport, Abrao

    2004-01-01

    The aim of this study is to evaluate the role of computed tomography and magnetic resonance imaging in the characterization of deep tissue extension of malignant tumors of the nasal cavity. Twelve patients diagnosed with malignant tumors of the nasal cavity were retrospectively evaluated at the Departments of Diagnostic Imaging and Head and Neck Surgery of the 'Complexo Hospitalar Heliopolis', Sao Paulo, Brazil, between 1990 and 2000. All cases were confirmed by histopathologic examination. The results were: extension to the maxillary and ethmoid sinuses was identified in six patients, extension to contralateral nasal cavity, orbit and lamina cribosa in five patients, extension to nasal pharynx and masticator space in two patients, extension to cavernous sinus, anterior/middle cranial fossa, pterygomaxillary fossa, inferior/superior orbital fissure, frontal sinus, contralateral ethmoid sinus, contralateral lamina cribosa, hard palate and pterygopalatine fossa in one patient. Conclusion: It is important to precisely assess the local extension and spread of tumor by computed tomography and magnetic resonance imaging in order to plan the approach to treatment, which will influence the prognosis. (author)

  12. Use of computed tomography and computed tomographic myelography for assessment of spinal tumoral calcinosis in a dog

    International Nuclear Information System (INIS)

    Ham, L.M. van; Bree, H.J. van; Tshamala, M.; Thoonen, H.

    1995-01-01

    Spinal tumoral calcinosis is reported in a Berner sennenhund puppy. The condition was manifested clinically as a non-ambulatory tetraparesis associated with neck pain. On survey radiographs there was a focal calcified mass at the atlantoaxial articulation. Computed tomography and computed tomographic myelography gave additional information on the extent of the mass and on the degree of spinal cord compression. The mass was removed surgically and the dog made a complete recovery

  13. Computer aided detection of ureteral stones in thin slice computed tomography volumes using Convolutional Neural Networks.

    Science.gov (United States)

    Längkvist, Martin; Jendeberg, Johan; Thunberg, Per; Loutfi, Amy; Lidén, Mats

    2018-06-01

    Computed tomography (CT) is the method of choice for diagnosing ureteral stones - kidney stones that obstruct the ureter. The purpose of this study is to develop a computer aided detection (CAD) algorithm for identifying a ureteral stone in thin slice CT volumes. The challenge in CAD for urinary stones lies in the similarity in shape and intensity of stones with non-stone structures and how to efficiently deal with large high-resolution CT volumes. We address these challenges by using a Convolutional Neural Network (CNN) that works directly on the high resolution CT volumes. The method is evaluated on a large data base of 465 clinically acquired high-resolution CT volumes of the urinary tract with labeling of ureteral stones performed by a radiologist. The best model using 2.5D input data and anatomical information achieved a sensitivity of 100% and an average of 2.68 false-positives per patient on a test set of 88 scans. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. A Computational Model of Hydraulic Volume Displacement Drive

    Directory of Open Access Journals (Sweden)

    V. N. Pil'gunov

    2014-01-01

    Full Text Available The paper offers a computational model of industrial-purpose hydraulic drive with two hydraulic volume adjustable working chamber machines (pump and motor. Adjustable pump equipped with the pressure control unit can be run together with several adjustable hydraulic motors on the principle of three-phase hydraulic socket-outlet with high-pressure lines, drain, and drainage system. The paper considers the pressure-controlled hydrostatic transmission with hydraulic motor as an output link. It shows a possibility to create a saving hydraulic drive using a functional tie between the adjusting parameters of the pump and hydraulic motor through the pressure difference, torque, and angular rate of the hydraulic motor shaft rotation. The programmable logic controller can implement such tie. The Coulomb and viscous frictions are taken into consideration when developing a computational model of the hydraulic volume displacement drive. Discharge balance considers external and internal leakages in equivalent clearances of hydraulic machines, as well as compression loss volume caused by hydraulic fluid compressibility and deformation of pipe walls. To correct dynamic properties of hydraulic drive, the paper offers that in discharge balance are included the additional regulated external leakages in the open circuit of hydraulic drive and regulated internal leakages in the closed-loop circuit. Generalized differential equations having functional multipliers and multilinked nature have been obtained to describe the operation of hydraulic positioning and speed drive with two hydraulic volume adjustable working chamber machines. It is shown that a proposed computational model of hydraulic drive can be taken into consideration in development of LS («Load-Sensing» drives, in which the pumping pressure is tuned to the value required for the most loaded slave motor to overcome the load. Results attained can be used both in designing the industrial-purpose heavy

  15. From computer-assisted intervention research to clinical impact: The need for a holistic approach.

    Science.gov (United States)

    Ourselin, Sébastien; Emberton, Mark; Vercauteren, Tom

    2016-10-01

    The early days of the field of medical image computing (MIC) and computer-assisted intervention (CAI), when publishing a strong self-contained methodological algorithm was enough to produce impact, are over. As a community, we now have substantial responsibility to translate our scientific progresses into improved patient care. In the field of computer-assisted interventions, the emphasis is also shifting from the mere use of well-known established imaging modalities and position trackers to the design and combination of innovative sensing, elaborate computational models and fine-grained clinical workflow analysis to create devices with unprecedented capabilities. The barriers to translating such devices in the complex and understandably heavily regulated surgical and interventional environment can seem daunting. Whether we leave the translation task mostly to our industrial partners or welcome, as researchers, an important share of it is up to us. We argue that embracing the complexity of surgical and interventional sciences is mandatory to the evolution of the field. Being able to do so requires large-scale infrastructure and a critical mass of expertise that very few research centres have. In this paper, we emphasise the need for a holistic approach to computer-assisted interventions where clinical, scientific, engineering and regulatory expertise are combined as a means of moving towards clinical impact. To ensure that the breadth of infrastructure and expertise required for translational computer-assisted intervention research does not lead to a situation where the field advances only thanks to a handful of exceptionally large research centres, we also advocate that solutions need to be designed to lower the barriers to entry. Inspired by fields such as particle physics and astronomy, we claim that centralised very large innovation centres with state of the art technology and health technology assessment capabilities backed by core support staff and open

  16. Volume of blood suctioned during vacuum-assisted breast biopsy predicts later hematoma formation

    Directory of Open Access Journals (Sweden)

    Panopoulou Effrosyni

    2010-03-01

    Full Text Available Abstract Background To evaluate whether the volume of blood suctioned during vacuum-assisted breast biopsy (VABB is associated with hematoma formation and progression, patient's age and histology of the lesion. Findings 177 women underwent VABB according to standardized protocol. The volume of blood suctioned and hematoma formation were noted at the end of the procedure, as did the subsequent development and progression of hematoma. First- and second-order logistic regression was performed, where appropriate. Cases with hematoma presented with greater volume of blood suctioned (63.8 ± 44.7 cc vs. 17.2 ± 32.9 cc; p Conclusion The likelihood of hematoma is increasing along with increasing amount of blood suctioned, reaching a plateau approximately at 80 cc of blood lost.

  17. Does the pancreatic volume reduction rate using serial computed tomographic volumetry predict new onset diabetes after pancreaticoduodenectomy?

    Science.gov (United States)

    Yun, Sung Pil; Seo, Hyung-Il; Kim, Suk; Kim, Dong Uk; Baek, Dong Hoon

    2017-01-01

    Abstract Volume reduction of the pancreatic tissues following a pancreatectomy can lead to the deterioration of glucose homeostasis. This is defined as pancreatogenic diabetes mellitus (DM). The objective of this study was to investigate the occurrence of new-onset DM (NODM) and evaluate the risk factors, including the pancreas volume reduction rate in patients undergoing pancreaticoduodenectomy (PD). Sixty-six patients without preoperative DM underwent PD for periampullary tumors between August 2007 and December 2012 and were included in this analysis. These patients underwent follow-up tests and abdominal computed tomography (CT) scan 7 days, 6 months, 12 months, 24 months, and 36 months after the operation. The pancreas volume reduction rate was calculated by CT volumetry. The patients were divided into 2 groups according to the postoperative development of DM. After PD, newly diagnosed DM occurred in 16 patients (24.2%). The incidence of DM was highest among patients with carcinomas with an advanced T stage. The pancreatic volume reduction rate after 6 and 12 months in the NODM group was significantly higher than the normal glucose group in the univariate analysis. In the multivariate analysis, the pancreatic volume reduction rate 6 months after PD was the only significant predictive factor for the development of NODM (P = 0.002). This study suggests that the pancreatic volume reduction rate 6 months after PD was the only significant predictive factor for the development of NODM. CT volumetry of the pancreas may be useful as a predictor of NODM after PD. PMID:28353594

  18. Computational Methods in Stochastic Dynamics Volume 2

    CERN Document Server

    Stefanou, George; Papadopoulos, Vissarion

    2013-01-01

    The considerable influence of inherent uncertainties on structural behavior has led the engineering community to recognize the importance of a stochastic approach to structural problems. Issues related to uncertainty quantification and its influence on the reliability of the computational models are continuously gaining in significance. In particular, the problems of dynamic response analysis and reliability assessment of structures with uncertain system and excitation parameters have been the subject of continuous research over the last two decades as a result of the increasing availability of powerful computing resources and technology.   This book is a follow up of a previous book with the same subject (ISBN 978-90-481-9986-0) and focuses on advanced computational methods and software tools which can highly assist in tackling complex problems in stochastic dynamic/seismic analysis and design of structures. The selected chapters are authored by some of the most active scholars in their respective areas and...

  19. Intelligent Computer-Assisted Instruction: A Review and Assessment of ICAI Research and Its Potential for Education.

    Science.gov (United States)

    Dede, Christopher J.; And Others

    The first of five sections in this report places intelligent computer-assisted instruction (ICAI) in its historical context through discussions of traditional computer-assisted instruction (CAI) linear and branching programs; TICCIT and PLATO IV, two CAI demonstration projects funded by the National Science Foundation; generative programs, the…

  20. Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Eun; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Jung, Woo Hyun; Choi, Byeong Don [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2016-12-15

    The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54⁓2.33, 5.16⁓8.06, 9.03⁓20.11 ml in MIP, respectively, 0.00⁓1.48, 0.00⁓8.47, 1.42⁓24.85 ml in MinIP, respectively and 0.00⁓1.17, 0.00⁓2.19, 0.04⁓3.35 ml in AVG, respectively. After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  1. Advanced 3D image processing techniques for liver and hepatic tumor location and volumetry

    Science.gov (United States)

    Chemouny, Stephane; Joyeux, Henri; Masson, Bruno; Borne, Frederic; Jaeger, Marc; Monga, Olivier

    1999-05-01

    To assist radiologists and physicians in diagnosing, and in treatment planning and evaluating in liver oncology, we have developed a fast and accurate segmentation of the liver and its lesions within CT-scan exams. The first step of our method is to reduce spatial resolution of CT images. This will have two effects: obtain near isotropic 3D data space and drastically decrease computational time for further processing. On a second step a 3D non-linear `edge- preserving' smoothing filtering is performed throughout the entire exam. On a third step the 3D regions coming out from the second step are homogeneous enough to allow a quite simple segmentation process, based on morphological operations, under supervisor control, ending up with accurate 3D regions of interest (ROI) of the liver and all the hepatic tumors. On a fourth step the ROIs are eventually set back into the original images, features like volume and location are immediately computed and displayed. The segmentation we get is as precise as a manual one but is much faster.

  2. Feedback in Computer Assisted Pronunciation Training: When technology meets pedagogy

    NARCIS (Netherlands)

    Neri, A.; Cucchiarini, C.; Strik, H.

    2002-01-01

    Computer Assisted Language Learning (CALL) has now established itself as a prolific and fast growing area whose advantages are already well-known to educators. Yet, many authors lament the lack of a reliable integrated conceptual framework linking technology advances and second language acquisition

  3. TU-G-BRA-05: Predicting Volume Change of the Tumor and Critical Structures Throughout Radiation Therapy by CT-CBCT Registration with Local Intensity Correction

    Energy Technology Data Exchange (ETDEWEB)

    Park, S; Robinson, A; Kiess, A; Quon, H; Wong, J; Lee, J [Johns Hopkins University, Baltimore, MD (United States); Plishker, W [IGI Technologies Inc., College Park, MD (United States); Shekhar, R [IGI Technologies Inc., College Park, MD (United States); Children’s National Medical Center, Washington, D.C. (United States)

    2015-06-15

    Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCT intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction

  4. Target coverage in image-guided stereotactic body radiotherapy of liver tumors.

    Science.gov (United States)

    Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M

    2007-05-01

    To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (design, patient stability in the SBF should be verified with portal imaging.

  5. Validating computationally predicted TMS stimulation areas using direct electrical stimulation in patients with brain tumors near precentral regions.

    Science.gov (United States)

    Opitz, Alexander; Zafar, Noman; Bockermann, Volker; Rohde, Veit; Paulus, Walter

    2014-01-01

    The spatial extent of transcranial magnetic stimulation (TMS) is of paramount interest for all studies employing this method. It is generally assumed that the induced electric field is the crucial parameter to determine which cortical regions are excited. While it is difficult to directly measure the electric field, one usually relies on computational models to estimate the electric field distribution. Direct electrical stimulation (DES) is a local brain stimulation method generally considered the gold standard to map structure-function relationships in the brain. Its application is typically limited to patients undergoing brain surgery. In this study we compare the computationally predicted stimulation area in TMS with the DES area in six patients with tumors near precentral regions. We combine a motor evoked potential (MEP) mapping experiment for both TMS and DES with realistic individual finite element method (FEM) simulations of the electric field distribution during TMS and DES. On average, stimulation areas in TMS and DES show an overlap of up to 80%, thus validating our computational physiology approach to estimate TMS excitation volumes. Our results can help in understanding the spatial spread of TMS effects and in optimizing stimulation protocols to more specifically target certain cortical regions based on computational modeling.

  6. Quantification of respiration-induced esophageal tumor motion using fiducial markers and four-dimensional computed tomography.

    Science.gov (United States)

    Jin, Peng; Hulshof, Maarten C C M; de Jong, Rianne; van Hooft, Jeanin E; Bel, Arjan; Alderliesten, Tanja

    2016-03-01

    Respiration-induced tumor motion is an important geometrical uncertainty in esophageal cancer radiation therapy. The aim of this study was to quantify this motion using fiducial markers and four-dimensional computed tomography (4DCT). Twenty esophageal cancer patients underwent endoscopy-guided marker implantation in the tumor volume and 4DCT acquisition. The 4DCT data were sorted into 10 breathing phases and the end-of-inhalation phase was selected as reference. We quantified for each visible marker (n=60) the motion in each phase and derived the peak-to-peak motion magnitude throughout the breathing cycle. The motion was quantified and analyzed for four different regions and in three orthogonal directions. The median(interquartile range) of the peak-to-peak magnitudes of the respiration-induced marker motion (left-right/anterior-posterior/cranial-caudal) was 1.5(0.5)/1.6(0.5)/2.9(1.4) mm for the proximal esophagus (n=6), 1.5(1.4)/1.4(1.3)/3.7(2.6) mm for the middle esophagus (n=12), 2.6(1.3)/3.3(1.8)/5.4(2.9) mm for the distal esophagus (n=25), and 3.7(2.1)/5.3(1.8)/8.2(3.1) mm for the proximal stomach (n=17). The variations in the results between the three directions, four regions, and patients suggest the need of individualized region-dependent anisotropic internal margins. Therefore, we recommend using markers with 4DCT to patient-specifically adapt the internal target volume (ITV). Without 4DCT, 3DCTs at the end-of-inhalation and end-of-exhalation phases could be alternatively applied for ITV individualization. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Integration of force reflection with tactile sensing for minimally invasive robotics-assisted tumor localization.

    Science.gov (United States)

    Talasaz, A; Patel, R V

    2013-01-01

    Tactile sensing and force reflection have been the subject of considerable research for tumor localization in soft-tissue palpation. The work presented in this paper investigates the relevance of force feedback (presented visually as well as directly) during tactile sensing (presented visually only) for tumor localization using an experimental setup close to one that could be applied for real robotics-assisted minimally invasive surgery. The setup is a teleoperated (master-slave) system facilitated with a state-of-the-art minimally invasive probe with a rigidly mounted tactile sensor at the tip and an externally mounted force sensor at the base of the probe. The objective is to capture the tactile information and measure the interaction forces between the probe and tissue during palpation and to explore how they can be integrated to improve the performance of tumor localization. To quantitatively explore the effect of force feedback on tactile sensing tumor localization, several experiments were conducted by human subjects to locate artificial tumors embedded in the ex vivo bovine livers. The results show that using tactile sensing in a force-controlled environment can realize, on average, 57 percent decrease in the maximum force and 55 percent decrease in the average force applied to tissue while increasing the tumor detection accuracy by up to 50 percent compared to the case of using tactile feedback alone. The results also show that while visual presentation of force feedback gives straightforward quantitative measures, improved performance of tactile sensing tumor localization is achieved at the expense of longer times for the user. Also, the quickness and intuitive data mapping of direct force feedback makes it more appealing to experienced users.

  8. COMPUTER ASSISTED LOOM IN THE REVIVAL OF CONTEMPORARY MONUMENTAL TAPESTRY

    Directory of Open Access Journals (Sweden)

    PINTILIE Anca-Aurelia

    2015-05-01

    Full Text Available The art of tapestry has its basics back in time, probably in the decorations of tent, the house of the nomad. Tapestry in its beginnings is the first wall of the nomad’s home and the decorative wall and canopy in the ancient Greek houses as architect Gottfried Semper stated in the nineteen century. The architectural approach is not unusual even in the next centuries. Tapestry becomes popular as a form of monumental art during the Middle Ages when it is used as decorative architectural element, coating the walls of medieval castles. During the next centuries dominated by decadent styles of baroque, rococo, the tapestry will lose its monumental spirit and architectural quality but at the middle of the XXth century a new approach will sustain the revival of the tapestry as monumental art. Later, in the XXIst century, renowned multimedia artists will approach this medium and will use computer assisted looms in ambitious tapestry projects. This technique will allow them to realize complex and exquisite tapestries, sustaining in this way the revival of the tapestry in the contemporary art world. The paper presents the importance of the architectural side of tapestry and the great achievement that computer assisted loom represents for this form of art. The research activity is willing to inform Romanian textile designers about the possibilities to create tapestries on computer assisted looms. The research was made during the initial stage of a doctoral thesis consisting in a documentary study on monumental aspects of contemporary tapestry.

  9. A Computer-Assisted Instruction in Teaching Abstract Statistics to Public Affairs Undergraduates

    Science.gov (United States)

    Ozturk, Ali Osman

    2012-01-01

    This article attempts to demonstrate the applicability of a computer-assisted instruction supported with simulated data in teaching abstract statistical concepts to political science and public affairs students in an introductory research methods course. The software is called the Elaboration Model Computer Exercise (EMCE) in that it takes a great…

  10. Tumor Volume Decrease via Feeder Occlusion for Treating a Large, Firm Trigone Meningioma.

    Science.gov (United States)

    Nakashima, Takuma; Hatano, Norikazu; Kanamori, Fumiaki; Muraoka, Shinsuke; Kawabata, Teppei; Takasu, Syuntaro; Watanabe, Tadashi; Kojima, Takao; Nagatani, Tetsuya; Seki, Yukio

    2018-01-01

    Trigone meningiomas are considered a surgical challenge, as they tend to be considerably large and hypervascularized at the time of presentation. We experienced a case of a large and very hard trigone meningioma that was effectively treated using initial microsurgical feeder occlusion followed by surgery in stages. A 19-year-old woman who presented with loss of consciousness was referred to our hospital for surgical treatment of a brain tumor. Radiological findings were compatible with a left ventricular trigone meningioma extending laterally in proximity to the Sylvian fissure. At initial surgery using the transsylvian approach, main feeders originating from the anterior and lateral posterior choroidal arteries were occluded at the inferior horn; however, only a small section of the tumor could initially be removed because of its firmness. Over time, feeder occlusion resulted in tumor necrosis and a 20% decrease in its diameter; the mass effect was alleviated within 1 year. The residual meningioma was then totally excised in staged surgical procedures after resection became more feasible owing to ischemia-induced partial softening of the tumor. When a trigone meningioma is large and very hard, initial microsurgical feeder occlusion in the inferior horn can be a safe and effective option, and can lead to necrosis, volume decrease, and partial softening of the residual tumor to allow for its staged surgical excision.

  11. Effects of a Computer-Assisted Concept Mapping Learning Strategy on EFL College Students' English Reading Comprehension

    Science.gov (United States)

    Liu, Pei-Lin; Chen, Chiu-Jung; Chang, Yu-Ju

    2010-01-01

    The purpose of this research was to investigate the effects of a computer-assisted concept mapping learning strategy on EFL college learners' English reading comprehension. The research questions were: (1) what was the influence of the computer-assisted concept mapping learning strategy on different learners' English reading comprehension? (2) did…

  12. Design of Intelligent Robot as A Tool for Teaching Media Based on Computer Interactive Learning and Computer Assisted Learning to Improve the Skill of University Student

    Science.gov (United States)

    Zuhrie, M. S.; Basuki, I.; Asto B, I. G. P.; Anifah, L.

    2018-01-01

    The focus of the research is the teaching module which incorporates manufacturing, planning mechanical designing, controlling system through microprocessor technology and maneuverability of the robot. Computer interactive and computer-assisted learning is strategies that emphasize the use of computers and learning aids (computer assisted learning) in teaching and learning activity. This research applied the 4-D model research and development. The model is suggested by Thiagarajan, et.al (1974). 4-D Model consists of four stages: Define Stage, Design Stage, Develop Stage, and Disseminate Stage. This research was conducted by applying the research design development with an objective to produce a tool of learning in the form of intelligent robot modules and kit based on Computer Interactive Learning and Computer Assisted Learning. From the data of the Indonesia Robot Contest during the period of 2009-2015, it can be seen that the modules that have been developed confirm the fourth stage of the research methods of development; disseminate method. The modules which have been developed for students guide students to produce Intelligent Robot Tool for Teaching Based on Computer Interactive Learning and Computer Assisted Learning. Results of students’ responses also showed a positive feedback to relate to the module of robotics and computer-based interactive learning.

  13. Solitary fibrous tumor: A center's experience and an overview of the symptomatology, the diagnostic and therapeutic procedures of this rare tumor

    Directory of Open Access Journals (Sweden)

    Wolfgang Hohenforst-Schmidt

    2017-01-01

    Full Text Available Solitary Fibrous Tumor of the Pleura (SFTP is a rare tumor of the pleura. Worldwide about 800 patients diagnosed with this oncological entity have been described in the existing literature. We report our center's 13 year experience. During this time three patients suffering from this rare disease have been treated in our department. All patients were asymptomatic and their diagnosis was initially triggered by a random finding in a routine chest x-ray. The diagnosis was set preoperatively through a needle biopsy under computer tomography (CT guidance. The tumors were resected surgically though video-assisted thoracoscopic surgery (VATS or thoracotomy. Because of the lack of specific guidelines due to the rarity of the disease a long-term, systematic follow-up was recommended and performed. Parallel an overview of the diagnostic and therapeutic procedures of the rare tumor is made.

  14. Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

    Energy Technology Data Exchange (ETDEWEB)

    Knybel, Lukas [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic); VŠB-Technical University of Ostrava, Ostrava (Czech Republic); Cvek, Jakub, E-mail: Jakub.cvek@fno.cz [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic); Molenda, Lukas; Stieberova, Natalie; Feltl, David [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic)

    2016-11-15

    Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P<.001). Motion amplitudes >15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P<.001). Interfraction variations and baseline changes >3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe

  15. Geometrical differences in target volumes based on 18F-fluorodeoxyglucose positron emission tomography/computed tomography and four-dimensional computed tomography maximum intensity projection images of primary thoracic esophageal cancer.

    Science.gov (United States)

    Guo, Y; Li, J; Wang, W; Zhang, Y; Wang, J; Duan, Y; Shang, D; Fu, Z

    2014-01-01

    The objective of the study was to compare geometrical differences of target volumes based on four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images of primary thoracic esophageal cancer for radiation treatment. Twenty-one patients with thoracic esophageal cancer sequentially underwent contrast-enhanced three-dimensional computed tomography (3DCT), 4DCT, and 18F-FDG PET/CT thoracic simulation scans during normal free breathing. The internal gross target volume defined as IGTVMIP was obtained by contouring on MIP images. The gross target volumes based on PET/CT images (GTVPET ) were determined with nine different standardized uptake value (SUV) thresholds and manual contouring: SUV≥2.0, 2.5, 3.0, 3.5 (SUVn); ≥20%, 25%, 30%, 35%, 40% of the maximum (percentages of SUVmax, SUVn%). The differences in volume ratio (VR), conformity index (CI), and degree of inclusion (DI) between IGTVMIP and GTVPET were investigated. The mean centroid distance between GTVPET and IGTVMIP ranged from 4.98 mm to 6.53 mm. The VR ranged from 0.37 to 1.34, being significantly (P<0.05) closest to 1 at SUV2.5 (0.94), SUV20% (1.07), or manual contouring (1.10). The mean CI ranged from 0.34 to 0.58, being significantly closest to 1 (P<0.05) at SUV2.0 (0.55), SUV2.5 (0.56), SUV20% (0.56), SUV25% (0.53), or manual contouring (0.58). The mean DI of GTVPET in IGTVMIP ranged from 0.61 to 0.91, and the mean DI of IGTVMIP in GTVPET ranged from 0.34 to 0.86. The SUV threshold setting of SUV2.5, SUV20% or manual contouring yields the best tumor VR and CI with internal-gross target volume contoured on MIP of 4DCT dataset, but 3DPET/CT and 4DCT MIP could not replace each other for motion encompassing target volume delineation for radiation treatment. © 2014 International Society for Diseases of the Esophagus.

  16. A Multidisciplinary Model for Development of Intelligent Computer-Assisted Instruction.

    Science.gov (United States)

    Park, Ok-choon; Seidel, Robert J.

    1989-01-01

    Proposes a schematic multidisciplinary model to help developers of intelligent computer-assisted instruction (ICAI) identify the types of required expertise and integrate them into a system. Highlights include domain types and expertise; knowledge acquisition; task analysis; knowledge representation; student modeling; diagnosis of learning needs;…

  17. The pedagogical effectiveness of ASR-based computer assisted pronunciation training

    NARCIS (Netherlands)

    Neri, A.

    2007-01-01

    Computer Assisted Pronunciation Training (CAPT) systems with Automatic Speech Recognition (ASR) technology have become increasingly popular to train pronunciation in the second language (L2). The advantage of these systems is the provision of a self-paced, stress-free type of training with automatic

  18. Effect of Tutorial Mode of Computer-Assisted Instruction on Students ...

    African Journals Online (AJOL)

    This study investigated the effect of Tutorial Mode of Computer- Assisted Instruction (CAI) on students' academic performance in practical geography in Nigeria, However, the sample population of eighty (80) Senior Secondary School Two geography students that were randomly selected from two privately owned secondary ...

  19. Reoxygenation of hypoxic cells by tumor shrinkage during irradiation. A computer simulation

    International Nuclear Information System (INIS)

    Kocher, M.; Treuer, H.

    1995-01-01

    A 3-dimensional computer simulation was developed in order to estimate the impact of tumor shrinkage on reoxygenation of chronic hypoxic tumor cells during a full course of fractionated irradiation. The growth of a small tumor situated in a vascularized stroma with 350 capillary cross-sections/mm 3 which were displaced by the growing tumor was simulated. Tumors contained 10 4 cells when irradiation started, intrinsic radiosensitivity was set to either low (α=0.3 Gy -1 , β=0.03 Gy -2 ) or high (α=0.4 Gy -1 , β=0.04 Gy -2 ) values. Oxygen enhancement ratio was 3.0, potential tumor doubling time T pot =1, 2 or 5 days. A simulated fractionated radiotherapy was carried out with daily fractions of 2.0 Gy, total dose 50 to 70 Gy. The presence or absence of factors preventing tumor cord shrinkage was also included. During the growth phase, all tumors developed a necrotic core with a hypoxic cell fraction of 25% under these conditions. During irradiation, the slower growing tumors (T pot =2 to 5 days) showed complete reoxygenation of the hypoxic cells after 30 to 40 Gy independent from radiosensitivity, undisturbed tumor shrinkage provided. If shrinkage was prevented, the hypoxic fraction rose to 100% after 30 to 50 Gy. Local tumor control, defined as the destruction of all clonogenic and hypoxic tumor cells increased by 20 to 100% due to reoxygenation and 50 Gy were enough in order to sterilize the tumors in these cases. In the fast growing tumors (T pot =1 day), reoxygenation was only observed in the case of high radiosensitivity and undisturbed tumor shrinkage. In these tumors reoxygenation increased the control rates by up to 60%. (orig./MG) [de

  20. Computer assisted orthopaedic and trauma surgery. State of the art and future perspectives

    NARCIS (Netherlands)

    Schep, N. W. L.; Broeders, I. A. M. J.; van der Werken, Chr

    2003-01-01

    In recent years computer technologies have become more and more integrated in surgical procedures. The potential advantages of computer assisted surgery (CAS) are: increase of accuracy of surgical interventions, less invasive operations, better planning and simulation and reduction of radiation

  1. Volume-Dependent Overestimation of Spontaneous Intracerebral Hematoma Volume by the ABC/2 Formula

    International Nuclear Information System (INIS)

    Chih-Wei Wang; Chun-Jung Juan; Hsian-He Hsu; Hua-Shan Liu; Cheng-Yu Chen; Chun-Jen Hsueh; Hung-Wen Kao; Guo-Shu Huang; Yi-Jui Liu; Chung-Ping Lo

    2009-01-01

    Background: Although the ABC/2 formula has been widely used to estimate the volume of intracerebral hematoma (ICH), the formula tends to overestimate hematoma volume. The volume-related imprecision of the ABC/2 formula has not been documented quantitatively. Purpose: To investigate the volume-dependent overestimation of the ABC/2 formula by comparing it with computer-assisted volumetric analysis (CAVA). Material and Methods: Forty patients who had suffered spontaneous ICH and who had undergone non-enhanced brain computed tomography scans were enrolled in this study. The ICH volume was estimated based on the ABC/2 formula and also calculated by CAVA. Based on the ICH volume calculated by the CAVA method, the patients were divided into three groups: group 1 consisted of 17 patients with an ICH volume of less than 20 ml; group 2 comprised 13 patients with an ICH volume of 20 to 40 ml; and group 3 was composed of 10 patients with an ICH volume larger than 40 ml. Results: The mean estimated hematoma volume was 43.6 ml when using the ABC/2 formula, compared with 33.8 ml when using the CAVA method. The mean estimated difference was 1.3 ml, 4.4 ml, and 31.4 ml for groups 1, 2, and 3, respectively, corresponding to an estimation error of 9.9%, 16.7%, and 37.1% by the ABC/2 formula (P<0.05). Conclusion: The ABC/2 formula significantly overestimates the volume of ICH. A positive association between the estimation error and the volume of ICH is demonstrated

  2. Glioblastoma progression is assisted by induction of immunosuppressive function of pericytes through interaction with tumor cells

    Science.gov (United States)

    Valdor, Rut; García-Bernal, David; Bueno, Carlos; Ródenas, Mónica; Moraleda, José M.; Macian, Fernando; Martínez, Salvador

    2017-01-01

    The establishment of immune tolerance during Glioblastoma Multiforme (GBM) progression, is characterized by high levels expression of anti-inflammatory cytokines, which suppress the function of tumor assocciated myeloid cells, and the activation and expansion of tumor antigen specific T cells. However, the mechanisms underlying the failed anti-tumor immune response around the blood vessels during GBM, are poorly understood. The consequences of possible interactions between cancer cells and the perivascular compartment might affect the tumor growth. In this work we show for the first time that GBM cells induce immunomodulatory changes in pericytes in a cell interaction-dependent manner, acquiring an immunosuppresive function that possibly assists the evasion of the anti-tumor immune response and consequently participates in tumor growth promotion. Expression of high levels of anti-inflammatory cytokines was detected in vitro and in vivo in brain pericytes that interacted with GBM cells (GBC-PC). Furthermore, reduction of surface expression of co-stimulatory molecules and major histocompatibility complex molecules in GBC-PC correlated with a failure of antigen presentation to T cells and the acquisition of the ability to supress T cell responses. In vivo, orthotopic xenotransplant of human glioblastoma in an immunocompetent mouse model showed significant GBM cell proliferation and tumor growth after the establishment of interspecific immunotolerance that followed GMB interaction with pericytes. PMID:28978142

  3. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    Science.gov (United States)

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual

  4. Registration of clinical volumes to beams-eye-view images for real-time tracking

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Jonathan H.; Rottmann, Joerg; Lewis, John H.; Mishra, Pankaj; Berbeco, Ross I., E-mail: rberbeco@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Keall, Paul J. [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, New South Wales 2006 (Australia)

    2014-12-15

    Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

  5. Computer Assisted Drafting (CNC) Drawings. Drafting Module 6. Instructor's Guide.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This Missouri Vocational Instruction Management System instructor's drafting guide has been keyed to the drafting competency profile developed by state industry and education professionals. This unit contains information on computer-assisted drafting drawings. The guide contains a cross-reference table of instructional materials and 20 worksheets.…

  6. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography.

    Science.gov (United States)

    Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P

    2014-11-01

    Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  7. Reliability of tumor volume estimation from MR images in patients with malignant glioma. Results from the American College of Radiology Imaging Network (ACRIN) 6662 Trial

    International Nuclear Information System (INIS)

    Ertl-Wagner, Birgit B.; Blume, Jeffrey D.; Herman, Benjamin; Peck, Donald; Udupa, Jayaram K.; Levering, Anthony; Schmalfuss, Ilona M.

    2009-01-01

    Reliable assessment of tumor growth in malignant glioma poses a common problem both clinically and when studying novel therapeutic agents. We aimed to evaluate two software-systems in their ability to estimate volume change of tumor and/or edema on magnetic resonance (MR) images of malignant gliomas. Twenty patients with malignant glioma were included from different sites. Serial post-operative MR images were assessed with two software systems representative of the two fundamental segmentation methods, single-image fuzzy analysis (3DVIEWNIX-TV) and multi-spectral-image analysis (Eigentool), and with a manual method by 16 independent readers (eight MR-certified technologists, four neuroradiology fellows, four neuroradiologists). Enhancing tumor volume and tumor volume plus edema were assessed independently by each reader. Intraclass correlation coefficients (ICCs), variance components, and prediction intervals were estimated. There were no significant differences in the average tumor volume change over time between the software systems (p > 0.05). Both software systems were much more reliable and yielded smaller prediction intervals than manual measurements. No significant differences were observed between the volume changes determined by fellows/neuroradiologists or technologists.Semi-automated software systems are reliable tools to serve as outcome parameters in clinical studies and the basis for therapeutic decision-making for malignant gliomas, whereas manual measurements are less reliable and should not be the basis for clinical or research outcome studies. (orig.)

  8. Computer Assisted Audit Techniques

    Directory of Open Access Journals (Sweden)

    Eugenia Iancu

    2007-01-01

    Full Text Available From the modern point of view, audit takes intoaccount especially the information systems representingmainly the examination performed by a professional asregards the manner for developing an activity by means ofcomparing it to the quality criteria specific to this activity.Having as reference point this very general definition ofauditing, it must be emphasized that the best known segmentof auditing is the financial audit that had a parallel evolutionto the accountancy one.The present day phase of developing the financial audithas as main trait the internationalization of the accountantprofessional. World wide there are multinational companiesthat offer services in the financial auditing, taxing andconsultancy domain. The auditors, natural persons and auditcompanies, take part at the works of the national andinternational authorities for setting out norms in theaccountancy and auditing domain.The computer assisted audit techniques can be classified inseveral manners according to the approaches used by theauditor. The most well-known techniques are comprised inthe following categories: testing data techniques, integratedtest, parallel simulation, revising the program logics,programs developed upon request, generalized auditsoftware, utility programs and expert systems.

  9. Effects of Using Simultaneous Prompting and Computer-Assisted Instruction during Small Group Instruction

    Science.gov (United States)

    Ozen, Arzu; Ergenekon, Yasemin; Ulke-Kurkcuoglu, Burcu

    2017-01-01

    The current study investigated the relation between simultaneous prompting (SP), computer-assisted instruction (CAI), and the receptive identification of target pictures (presented on laptop computer) for four preschool students with developmental disabilities. The students' acquisition of nontarget information through observational learning also…

  10. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  11. The perioperative outcomes between renal hilar and non-hilar tumors following robotic-assisted partial nephrectomy (RAPN).

    Science.gov (United States)

    Lu, Shih-Yen; Chung, Hsiao-Jen; Huang, Eric Yi-Hsiu; Lin, Tzu-Pin; Lin, Alex T L

    2018-03-15

    The aim of this study was to compare the perioperative outcomes between renal hilar tumors and non-hilar tumors after robotic-assisted partial nephrectomy (RAPN). A retrospective review of consecutive patients who underwent RAPN from December 2009 to September 2015 at our institution was recruited. Perioperative outcomes including demographic characteristics, perioperative, pathological and renal function outcomes were compared between the hilar group (n = 30) and non-hilar group (n = 170). In characteristics, hilar group was younger (52.4 vs. 58 years, p = 0.04) and had less body mass index (23.7 vs. 25.4 kg/m 2 , p = 0.018). Hilar group had larger tumor size (4.8 vs. 3.7 cm, p = 0.009), higher Preoperative Aspects and Dimensions Used for an Anatomical (PADUA) score (10.7 vs. 8.5, p Hilar tumor was associated with longer operative time (293.6 vs. 240.5 min, p = 0.001) and warm ischemia time (39.9 vs. 21.8 min, p hilar tumor patients had no difference of the change of creatinine and estimated glomerular filtration rate (eGFR) at postoperative 6 and 12 month as compared with non-hilar tumor patients. For renal hilar tumor, RAPN could provide acceptable results of perioperative, pathological and renal function outcome as compared with non-hilar tumor group. Thus RAPN is a safe and effective nephron-sparing surgery technique for renal hilar tumors. Copyright © 2018. Published by Elsevier Taiwan LLC.

  12. High-volume intensive training course: a new paradigm for video-assisted thoracoscopic surgery education.

    Science.gov (United States)

    Sihoe, Alan D L; Gonzalez-Rivas, Diego; Yang, Timothy Y; Zhu, Yuming; Jiang, Gening

    2018-03-27

    The emergence of ultra-high-volume centres promises new opportunities for thoracic surgical training. The goal of this study was to investigate the effectiveness of a novel observership course in teaching video-assisted thoracoscopic surgery (VATS) at an ultra-high-volume centre. Two-week courses in VATS at a specialist unit now performing >10 000 major lung resections annually (>50 daily on average) were attended by 230 surgeons from around the world from 2013 to 2016. An online survey preserving responder anonymity was completed by 156 attendees (67.8%). Attendees included 37% from Western Europe, 18% from Eastern Europe and 17% from Latin America. Experience with open thoracic surgery for more than 5 years was reported by 67%, but 79% had less than 5 years of VATS lobectomy experience. During the course, 70% observed over 30 uniportal VATS operations (including 38% observing over 50), and 69% attended an animal wet lab. Although 72% of the responders attended the course less than 12 months ago, the number of ports used (P < 0.001), operation times (P < 0.001) and conversion rates (P < 0.001) reported by the responders were reduced significantly after the course. Improvements in the problem areas of tissue retraction, instrumentation, stapler application and coordination with the assistant during VATS were reported by 56%, 57%, 58% and 53%, respectively. Of those who had attended other VATS courses previously, 87% preferred the training from this high-volume course. High-volume intensive observership training at an ultra-high-volume centre may improve VATS proficiency in a short period of time, and may provide a time-efficient modality for future thoracic surgical training.

  13. Regorafenib effects on human colon carcinoma xenografts monitored by dynamic contrast-enhanced computed tomography with immunohistochemical validation.

    Directory of Open Access Journals (Sweden)

    Clemens C Cyran

    Full Text Available To investigate dynamic contrast-enhanced computed tomography for monitoring the effects of regorafenib on experimental colon carcinomas in rats by quantitative assessments of tumor microcirculation parameters with immunohistochemical validation.Colon carcinoma xenografts (HT-29 implanted subcutaneously in female athymic rats (n = 15 were imaged at baseline and after a one-week treatment with regorafenib by dynamic contrast-enhanced computed tomography (128-slice dual-source computed tomography. The therapy group (n = 7 received regorafenib daily (10 mg/kg bodyweight. Quantitative parameters of tumor microcirculation (plasma flow, mL/100 mL/min, endothelial permeability (PS, mL/100 mL/min, and tumor vascularity (plasma volume, % were calculated using a 2-compartment uptake model. Dynamic contrast-enhanced computed tomography parameters were validated with immunohistochemical assessments of tumor microvascular density (CD-31, tumor cell apoptosis (TUNEL, and proliferation (Ki-67.Regorafenib suppressed tumor vascularity (15.7±5.3 to 5.5±3.5%; p<0.05 and tumor perfusion (12.8±2.3 to 8.8±2.9 mL/100 mL/min; p = 0.063. Significantly lower microvascular density was observed in the therapy group (CD-31; 48±10 vs. 113±25, p<0.05. In regorafenib-treated tumors, significantly more apoptotic cells (TUNEL; 11844±2927 vs. 5097±3463, p<0.05 were observed. Dynamic contrast-enhanced computed tomography tumor perfusion and tumor vascularity correlated significantly (p<0.05 with microvascular density (CD-31; r = 0.84 and 0.66 and inversely with apoptosis (TUNEL; r = -0.66 and -0.71.Regorafenib significantly suppressed tumor vascularity (plasma volume quantified by dynamic contrast-enhanced computed tomography in experimental colon carcinomas in rats with good-to-moderate correlations to an immunohistochemical gold standard. Tumor response biomarkers assessed by dynamic contrast-enhanced computed tomography may be a promising future

  14. Less Daily Computer Use is Related to Smaller Hippocampal Volumes in Cognitively Intact Elderly.

    Science.gov (United States)

    Silbert, Lisa C; Dodge, Hiroko H; Lahna, David; Promjunyakul, Nutta-On; Austin, Daniel; Mattek, Nora; Erten-Lyons, Deniz; Kaye, Jeffrey A

    2016-01-01

    Computer use is becoming a common activity in the daily life of older individuals and declines over time in those with mild cognitive impairment (MCI). The relationship between daily computer use (DCU) and imaging markers of neurodegeneration is unknown. The objective of this study was to examine the relationship between average DCU and volumetric markers of neurodegeneration on brain MRI. Cognitively intact volunteers enrolled in the Intelligent Systems for Assessing Aging Change study underwent MRI. Total in-home computer use per day was calculated using mouse movement detection and averaged over a one-month period surrounding the MRI. Spearman's rank order correlation (univariate analysis) and linear regression models (multivariate analysis) examined hippocampal, gray matter (GM), white matter hyperintensity (WMH), and ventricular cerebral spinal fluid (vCSF) volumes in relation to DCU. A voxel-based morphometry analysis identified relationships between regional GM density and DCU. Twenty-seven cognitively intact participants used their computer for 51.3 minutes per day on average. Less DCU was associated with smaller hippocampal volumes (r = 0.48, p = 0.01), but not total GM, WMH, or vCSF volumes. After adjusting for age, education, and gender, less DCU remained associated with smaller hippocampal volume (p = 0.01). Voxel-wise analysis demonstrated that less daily computer use was associated with decreased GM density in the bilateral hippocampi and temporal lobes. Less daily computer use is associated with smaller brain volume in regions that are integral to memory function and known to be involved early with Alzheimer's pathology and conversion to dementia. Continuous monitoring of daily computer use may detect signs of preclinical neurodegeneration in older individuals at risk for dementia.

  15. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    Science.gov (United States)

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  16. Audio computer-assisted self interview compared to traditional interview in an HIV-related behavioral survey in Vietnam.

    Science.gov (United States)

    Le, Linh Cu; Vu, Lan T H

    2012-10-01

    Globally, population surveys on HIV/AIDS and other sensitive topics have been using audio computer-assisted self interview for many years. This interview technique, however, is still new to Vietnam and little is known about its application and impact in general population surveys. One plausible hypothesis is that residents of Vietnam interviewed using this technique may provide a higher response rate and be more willing to reveal their true behaviors than if interviewed with traditional methods. This study aims to compare audio computer-assisted self interview with traditional face-to-face personal interview and self-administered interview with regard to rates of refusal and affirmative responses to questions on sensitive topics related to HIV/AIDS. In June 2010, a randomized study was conducted in three cities (Ha Noi, Da Nan and Can Tho), using a sample of 4049 residents aged 15 to 49 years. Respondents were randomly assigned to one of three interviewing methods: audio computer-assisted self interview, personal face-to-face interview, and self-administered paper interview. Instead of providing answers directly to interviewer questions as with traditional methods, audio computer-assisted self-interview respondents read the questions displayed on a laptop screen, while listening to the questions through audio headphones, then entered responses using a laptop keyboard. A MySQL database was used for data management and SPSS statistical package version 18 used for data analysis with bivariate and multivariate statistical techniques. Rates of high risk behaviors and mean values of continuous variables were compared for the three data collection methods. Audio computer-assisted self interview showed advantages over comparison techniques, achieving lower refusal rates and reporting higher prevalence of some sensitive and risk behaviors (perhaps indication of more truthful answers). Premarital sex was reported by 20.4% in the audio computer-assisted self-interview survey

  17. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    International Nuclear Information System (INIS)

    Heeswijk, Miriam M. van; Lambregts, Doenja M.J.; Griethuysen, Joost J.M. van; Oei, Stanley; Rao, Sheng-Xiang; Graaff, Carla A.M. de; Vliegen, Roy F.A.; Beets, Geerard L.; Papanikolaou, Nikos; Beets-Tan, Regina G.H.

    2016-01-01

    Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the

  18. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    Energy Technology Data Exchange (ETDEWEB)

    Heeswijk, Miriam M. van [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Centre, Maastricht (Netherlands); Lambregts, Doenja M.J., E-mail: d.lambregts@nki.nl [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Griethuysen, Joost J.M. van [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Oei, Stanley [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Rao, Sheng-Xiang [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai (China); Graaff, Carla A.M. de [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Vliegen, Roy F.A. [Atrium Medical Centre Parkstad/Zuyderland Medical Centre, Heerlen (Netherlands); Beets, Geerard L. [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Surgery, The Netherlands Cancer Institute, Amsterdam (Netherlands); Papanikolaou, Nikos [Laboratory of Computational Medicine, Institute of Computer Science, FORTH, Heraklion, Crete (Greece); Beets-Tan, Regina G.H. [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2016-03-15

    Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the

  19. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    Science.gov (United States)

    van Heeswijk, Miriam M; Lambregts, Doenja M J; van Griethuysen, Joost J M; Oei, Stanley; Rao, Sheng-Xiang; de Graaff, Carla A M; Vliegen, Roy F A; Beets, Geerard L; Papanikolaou, Nikos; Beets-Tan, Regina G H

    2016-03-15

    Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and

  20. Semiautomated volumetric response evaluation as an imaging biomarker in superior sulcus tumors

    International Nuclear Information System (INIS)

    Vos, C.G.; Paul, M.A.; Dahele, M.; Soernsen de Koste, J.R. van; Senan, S.; Bahce, I.; Smit, E.F.; Thunnissen, E.; Hartemink, K.J.

    2014-01-01

    Volumetric response to therapy has been suggested as a biomarker for patient-centered outcomes. The primary aim of this pilot study was to investigate whether the volumetric response to induction chemoradiotherapy was associated with pathological complete response (pCR) or survival in patients with superior sulcus tumors managed with trimodality therapy. The secondary aim was to evaluate a semiautomated method for serial volume assessment. In this retrospective study, treatment outcomes were obtained from a departmental database. The tumor was delineated on the computed tomography (CT) scan used for radiotherapy planning, which was typically performed during the first cycle of chemotherapy. These contours were transferred to the post-chemoradiotherapy diagnostic CT scan using deformable image registration (DIR) with/without manual editing. CT scans from 30 eligible patients were analyzed. Median follow-up was 51 months. Neither absolute nor relative reduction in tumor volume following chemoradiotherapy correlated with pCR or 2-year survival. The tumor volumes determined by DIR alone and DIR + manual editing correlated to a high degree (R 2 = 0.99, P < 0.01). Volumetric response to induction chemoradiotherapy was not correlated with pCR or survival in patients with superior sulcus tumors managed with trimodality therapy. DIR-based contour propagation merits further evaluation as a tool for serial volumetric assessment. (orig.)

  1. Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Aghaei, Faranak; Tan, Maxine; Liu, Hong; Zheng, Bin; Hollingsworth, Alan B.; Qian, Wei

    2015-01-01

    Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy

  2. Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Aghaei, Faranak; Tan, Maxine; Liu, Hong; Zheng, Bin, E-mail: Bin.Zheng-1@ou.edu [School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States); Hollingsworth, Alan B. [Mercy Women’s Center, Mercy Health Center, Oklahoma City, Oklahoma 73120 (United States); Qian, Wei [Department of Electrical and Computer Engineering, University of Texas, El Paso, Texas 79968 (United States)

    2015-11-15

    Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy.

  3. Optimizing Computer Assisted Instruction By Applying Principles of Learning Theory.

    Science.gov (United States)

    Edwards, Thomas O.

    The development of learning theory and its application to computer-assisted instruction (CAI) are described. Among the early theoretical constructs thought to be important are E. L. Thorndike's concept of learning connectisms, Neal Miller's theory of motivation, and B. F. Skinner's theory of operant conditioning. Early devices incorporating those…

  4. Computer-Assisted Instruction: A Case Study of Two Charter Schools

    Science.gov (United States)

    Keengwe, Jared; Hussein, Farhan

    2013-01-01

    The purpose of this study was to examine the relationship in achievement gap between English language learners (ELLs) utilizing computer-assisted instruction (CAI) in the classroom, and ELLs relying solely on traditional classroom instruction. The study findings showed that students using CAI to supplement traditional lectures performed better…

  5. Radiofrequency ablation of liver tumors (II): clinical application and outcomes.

    Science.gov (United States)

    Vanagas, Tomas; Gulbinas, Antanas; Pundzius, Juozas; Barauskas, Giedrius

    2010-01-01

    Radiofrequency ablation is one of the alternatives in the management of liver tumors, especially in patients who are not candidates for surgery. The aim of this article is to review applicability of radiofrequency ablation achieving complete tumor destruction, utility of imaging techniques for patients' follow-up, indications for local ablative procedures, procedure-associated morbidity and mortality, and long-term results in patients with different tumors. The success of local thermal ablation consists in creating adequate volumes of tissue destruction with adequate "clear margin," depending on improved delivery of radiofrequency energy and modulated tissue biophysiology. Different volumes of coagulation necrosis are achieved applying different types of electrodes, pulsing energy sources, utilizing sophisticated ablation schemes. Some additional methods are used to increase the overall deposition of energy through alterations in tissue electrical conductivity, to improve heat retention within the tissue, and to modulate tolerance of tumor tissue to hyperthermia. Contrast-enhanced computed tomography, magnetic resonance imaging, ultrasound or positron emission tomography are applied to control the effectiveness of radiofrequency ablation. The long-term results of radiofrequency ablation are controversial.

  6. Left ventricular volume determination from single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-01-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting

  7. Left ventricular volume determination from single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-02-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting.

  8. Towards an integrative computational model for simulating tumor growth and response to radiation therapy

    Science.gov (United States)

    Marrero, Carlos Sosa; Aubert, Vivien; Ciferri, Nicolas; Hernández, Alfredo; de Crevoisier, Renaud; Acosta, Oscar

    2017-11-01

    Understanding the response to irradiation in cancer radiotherapy (RT) may help devising new strategies with improved tumor local control. Computational models may allow to unravel the underlying radiosensitive mechanisms intervening in the dose-response relationship. By using extensive simulations a wide range of parameters may be evaluated providing insights on tumor response thus generating useful data to plan modified treatments. We propose in this paper a computational model of tumor growth and radiation response which allows to simulate a whole RT protocol. Proliferation of tumor cells, cell life-cycle, oxygen diffusion, radiosensitivity, RT response and resorption of killed cells were implemented in a multiscale framework. The model was developed in C++, using the Multi-formalism Modeling and Simulation Library (M2SL). Radiosensitivity parameters extracted from literature enabled us to simulate in a regular grid (voxel-wise) a prostate cell tissue. Histopathological specimens with different aggressiveness levels extracted from patients after prostatectomy were used to initialize in silico simulations. Results on tumor growth exhibit a good agreement with data from in vitro studies. Moreover, standard fractionation of 2 Gy/fraction, with a total dose of 80 Gy as a real RT treatment was applied with varying radiosensitivity and oxygen diffusion parameters. As expected, the high influence of these parameters was observed by measuring the percentage of survival tumor cell after RT. This work paves the way to further models allowing to simulate increased doses in modified hypofractionated schemes and to develop new patient-specific combined therapies.

  9. Using computer-assisted learning to engage diverse learning styles in understanding business management principles.

    Science.gov (United States)

    Frost, Mary E; Derby, Dustin C; Haan, Andrea G

    2013-01-01

    Objective : Changes in small business and insurance present challenges for newly graduated chiropractors. Technology that reaches identified, diverse learning styles may assist the chiropractic student in business classes to meet course outcomes better. Thus, the purpose of our study is to determine if the use of technology-based instructional aids enhance students' mastery of course learning outcomes. Methods : Using convenience sampling, 86 students completed a survey assessing course learning outcomes, learning style, and the helpfulness of lecture and computer-assisted learning related to content mastery. Quantitative analyses occurred. Results : Although respondents reported not finding the computer-assisted learning as helpful as the lecture, significant relationships were found between pre- and post-assisted learning measures of the learning outcomes 1 and 2 for the visual and kinesthetic groups. Surprisingly, however, all learning style groups exhibited significant pre- and post-assisted learning appraisal relationships with learning outcomes 3 and 4. Conclusion : While evidence exists within the current study of a relationship between students' learning of the course content corollary to the use of technologic instructional aids, the exact nature of the relationship remains unclear.

  10. Computer Assisted Language Learning (CALL): Using Internet for Effective Language Learning

    NARCIS (Netherlands)

    Kremenska, Anelly

    2006-01-01

    Please, cite this publication as: Kremenska, A. (2006). Computer Assisted Language Learning (CALL): Using Internet for Effective Language Learning. Proceedings of International Workshop in Learning Networks for Lifelong Competence Development, TENCompetence Conference. March 30th-31st, Sofia,

  11. Transcranial sonography: integration into target volume definition for glioblastoma multiforme

    International Nuclear Information System (INIS)

    Vordermark, Dirk; Becker, Georg; Flentje, Michael; Richter, Susanne; Goerttler-Krauspe, Irene; Koelbl, Oliver

    2000-01-01

    Purpose: Recent studies indicate that transcranial sonography (TCS) reliably displays the extension of malignant brain tumors. The effect of integrating TCS into radiotherapy planning for glioblastoma multiforme (GBM) was investigated herein. Methods and Materials: Thirteen patients subtotally resected for GBM underwent TCS during radiotherapy planning and were conventionally treated (54 to 60 Gy). Gross tumor volumes (GTVs) and stereotactic boost planning target volumes (PTVs, 3-mm margin) were created, based on contrast enhancement on computed tomography (CT) only (PTV CT ) or the combined CT and TCS information (PTV CT+TCS ). Noncoplonar conformal treatment plans for both PTVs were compared. Tumor progression patterns and preoperative magnetic resonance imaging (MRI) were related to both PTVs. Results: A sufficient temporal bone window for TCS was present in 11 of 13 patients. GTVs as defined by TCS were considerably larger than the respective CT volumes: Of the composite GTV CT+TCS (median volume 42 ml), 23%, 13%, and 66% (medians) were covered by the overlap of both methods, CT only and TCS only, respectively. Median sizes of PTV CT and PTV CT+TCS were 34 and 74 ml, respectively. Addition of TCS to CT information led to a median increase of the volume irradiated within the 80% isodose by 32 ml (median factor 1.51). PTV CT+TCS volume was at median 24% of a 'conventional' MRI(T2)-based PTV. Of eight progressions analyzed, three and six occurred inside the 80% isodose of the plans for PTV CT and for PTV CT+TCS , respectively. Conclusion: Addition of TCS tumor volume to the contrast-enhancing CT volume in postoperative radiotherapy planning for GBM increases the treated volume by a median factor of 1.5. Since a high frequency of marginal recurrences is reported from dose-escalation trials of this disease, TCS may complement established methods in PTV definition

  12. Evaluation of gastrointestinal stromal tumors by multislice computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Porto, Fabiano Elias; Baroni, Ronaldo Hueb; Rocha, Manoel de Souza; Funari, Marcelo Buarque de Gusmao; Macedo, Antonio Luiz de Vasconcellos; Pelizon, Christina Helena de Toledo

    2005-01-01

    This article presents three cases of gastrointestinal stromal tumors with clinical manifestations and pathological features, along with differential diagnoses, with special emphasis on multislice computed tomography and magnetic resonance imaging findings. (author)

  13. Evaluation of the effect of prostate volume change on tumor control probability in LDR brachytherapy.

    Science.gov (United States)

    Knaup, Courtney; Mavroidis, Panayiotis; Stathakis, Sotirios; Smith, Mark; Swanson, Gregory; Papanikolaou, Niko

    2011-09-01

    This study evaluates low dose-rate brachytherapy (LDR) prostate plans to determine the biological effect of dose degradation due to prostate volume changes. In this study, 39 patients were evaluated. Pre-implant prostate volume was determined using ultrasound. These images were used with the treatment planning system (Nucletron Spot Pro 3.1(®)) to create treatment plans using (103)Pd seeds. Following the implant, patients were imaged using CT for post-implant dosimetry. From the pre and post-implant DVHs, the biologically equivalent dose and the tumor control probability (TCP) were determined using the biologically effective uniform dose. The model used RBE = 1.75 and α/β = 2 Gy. The prostate volume changed between pre and post implant image sets ranged from -8% to 110%. TCP and the mean dose were reduced up to 21% and 56%, respectively. TCP is observed to decrease as the mean dose decreases to the prostate. The post-implant tumor dose was generally observed to decrease, compared to the planned dose. A critical uniform dose of 130 Gy was established. Below this dose, TCP begins to fall-off. It was also determined that patients with a small prostates were more likely to suffer TCP decrease. The biological effect of post operative prostate growth due to operative trauma in LDR was evaluated using the concept. The post-implant dose was lower than the planned dose due to an increase of prostate volume post-implant. A critical uniform dose of 130 Gy was determined, below which TCP begun to decline.

  14. Computed tomography in the CSF seeding of brain tumors

    International Nuclear Information System (INIS)

    Nakagawa, Yoshio; Fujimoto, Masahito; Naruse, Shoji; Ueda, Satoshi; Hirakawa, Kimiyoshi

    1981-01-01

    In the past three years nine cases of brain tumors with CSF seeding have been revealed by computed tomography (CT). We have been analyzing the CT pattern of CSF seeding, CSF cytology, and spinal metastasis. The brain tumors were classified as follows: five medulloblastomas, two glioblastomas, one germinoma, and one meningeal carcinomatosis. Their CT patterns were divided into three groups: 1) diffuse seeding of the basal cisterns. 2) invasion of the ventricular wall. 3) solitary metastasis in the ventricle. The subarachnoid seeding included four medulloblastomas and one meningeal carcinomatosis. The second type of seeding included two glioblastomas and one germinoma. One medulloblastoma had a single metastasis in the lateral ventricle. In the medulloblastomas, the diffuse seeding of the basal cisterns was more common than the invasion of the ventricular wall or solitary metastasis in the ventricle. Medulloblastomas were also accompanied by spinal metastasis. Because there were many cases of spinal metastasis in the first type of seeding, we concluded that there was a definite correlation between the CSF seeding of the basal cisterns and spinal metastasis. Needless to say, CT was the most important method for the diagnosis of the CSF seeding of brain tumors. However, because there was a case of CSF seeding which had not been demonstrated by CT, we also emphasized the importance of neurological examination and CSF cytology in the diagnosis of the CSF seeding of brain tumors. (author)

  15. Computer-generated display system guidelines. Volume 2. Developing an evaluation plan

    International Nuclear Information System (INIS)

    1984-09-01

    Volume 1 of this report provides guidance to utilities on the design of displays and the selection and retrofit of a computer-generated display system in the control room of an operating nuclear power plant. Volume 2 provides guidance on planning and managing empirical evaluation of computer-generated display systems, particularly when these displays are primary elements of computer-based operator aids. The guidance provided is in terms of a multilevel evaluation methodology that enables sequential consideration of three primary issues: (1) compatibility; (2) understandability; and (3) effectiveness. The evaluation process approaches these three issues with a top-down review of system objectives, functions, tasks, and information requirements. The process then moves bottom-up from lower-level to higher-level issues, employing different evaluation methods at each level in order to maximize the efficiency and effectiveness of the evaluation process

  16. Estimation of Tumor Volumes by 11C-MeAIB and 18F-FDG PET in an Orthotopic Glioblastoma Rat Model

    DEFF Research Database (Denmark)

    Halle, Bo; Thisgaard, Helge; Hvidsten, Svend

    2015-01-01

    starting immediately after the injection of 11C-methylaminoisobutyric acid (11C-MeAIB). One hour later, 18F-FDG was injected, followed by a 3-h dynamic PET scan. Images were reconstructed using 2-dimensional ordered-subsets expectation maximization and 3-dimensional maximum a posteriori probability (MAP3D......UNLABELLED: Brain tumor volume assessment is a major challenge. Molecular imaging using PET may be a promising option because it reflects the biologically active cells. We compared the agreement between PET- and histology-derived tumor volumes in an orthotopic glioblastoma rat model...... with a noninfiltrating (U87MG) and an infiltrating (T87) tumor phenotype using 2 different radiotracers, 2 different image reconstruction algorithms, parametric imaging, and 2 different image segmentation techniques. METHODS: Rats with U87MG- and T87-derived glioblastomas were continuously scanned with PET for 1 h...

  17. Computer assisted tutoring in radiology

    International Nuclear Information System (INIS)

    Jeffery, N.

    1997-02-01

    The computer-based tutoring of visual concepts such as radiological images is a largely unexplored area. A review of the literature highlights limited use of computers as a means of radiological education, with the majority of systems being little more than hypermedia prototypes, on-line teaching files, and passive CD-Roms. Very few of the systems discussed in the research literature draw on the work from cognitive science and educational psychology for tutoring visual concepts. This thesis details and evaluates a method for indexing and retrieving images from large image databases via a cognitively informed graphical representation of visual concepts. This representation is derived using Multiple Correspondence Analysis from a statistical analysis of features present in the images. It is intended that this representation be used to assist in the computer based teaching of any discipline that requires the tutoring of visual concepts. The domain used as a test bed for this research is Magnetic Resonance Imaging in neuroradiology. Tutoring the interpretation of MR scans of the head represents a real practical problem due to the inherent complexity of the brain and variations in tissue contrast within image sequence and disease/pathology. The literature of concept categorisation and representation is critically reviewed to inform the design of a graphical representation of a concept (a pathology in the application domain). A specification for the design of an explicit representation of visual concepts is drawn from this literature review, together with methods of tutoring based around this model. A methodology for producing this representation is described, and implemented in the development of an overview plot for the concept of a disease of the brain, with associated statistical measures derived and operationalised for typicality and similarity of cases within a disease. These measures are precursors to the development of computer based tutoring strategies for image

  18. Computer assisted tutoring in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Jeffery, N

    1997-02-01

    The computer-based tutoring of visual concepts such as radiological images is a largely unexplored area. A review of the literature highlights limited use of computers as a means of radiological education, with the majority of systems being little more than hypermedia prototypes, on-line teaching files, and passive CD-Roms. Very few of the systems discussed in the research literature draw on the work from cognitive science and educational psychology for tutoring visual concepts. This thesis details and evaluates a method for indexing and retrieving images from large image databases via a cognitively informed graphical representation of visual concepts. This representation is derived using Multiple Correspondence Analysis from a statistical analysis of features present in the images. It is intended that this representation be used to assist in the computer based teaching of any discipline that requires the tutoring of visual concepts. The domain used as a test bed for this research is Magnetic Resonance Imaging in neuroradiology. Tutoring the interpretation of MR scans of the head represents a real practical problem due to the inherent complexity of the brain and variations in tissue contrast within image sequence and disease/pathology. The literature of concept categorisation and representation is critically reviewed to inform the design of a graphical representation of a concept (a pathology in the application domain). A specification for the design of an explicit representation of visual concepts is drawn from this literature review, together with methods of tutoring based around this model. A methodology for producing this representation is described, and implemented in the development of an overview plot for the concept of a disease of the brain, with associated statistical measures derived and operationalised for typicality and similarity of cases within a disease. These measures are precursors to the development of computer based tutoring strategies for image

  19. Application of Computer-Assisted Learning Methods in the Teaching of Chemical Spectroscopy.

    Science.gov (United States)

    Ayscough, P. B.; And Others

    1979-01-01

    Discusses the application of computer-assisted learning methods to the interpretation of infrared, nuclear magnetic resonance, and mass spectra; and outlines extensions into the area of integrated spectroscopy. (Author/CMV)

  20. Faculty Attitudes towards Computer Assisted Instruction at the University of Gaziantep

    Directory of Open Access Journals (Sweden)

    Filiz Yalçın TILFARLIOĞLU

    2006-04-01

    Full Text Available This study aims at revealing faculty attitudes towards computer assistedinstruction at University of Gaziantep, Turkey in a multifaceted way. Additionally, ittries to determine underlying factors that shape these attitudes. After a pilot study, thequestionnaire was applied to a sample population of 145 faculty that were chosenrandomly. The results revealed that faculty attitudes towards computer assistedinsruction are positive. Age, sex, teaching experience, level of proficiency in Englishand computer usage skills have no or little effects over these attitudes.According to theresults of the study, faculty who have prior knowledge on computers expose ratherpositive attitudes towards computers in education.Another important outcome of thestudy is the existence of a gender gap in terms of computer assisted instruction.Althoughthere seems to be no difference between male and female faculty concerning theirbackground education regarding computers, male faculty feel confident about thematter, whereas female faculty feel uncomfortable about using computers in theirlessons.