WorldWideScience

Sample records for computer-assisted diagnostic system

  1. Computer assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.; Jaffe, C.C.; Felix, R.

    1993-01-01

    The proceedings of the CAR'93 symposium present the 126 oral papers and the 58 posters contributed to the four Technical Sessions entitled: (1) Image Management, (2) Medical Workstations, (3) Digital Image Generation - DIG, and (4) Application Systems - AS. Topics discussed in Session (1) are: picture archiving and communication systems, teleradiology, hospital information systems and radiological information systems, technology assessment and implications, standards, and data bases. Session (2) deals with computer vision, computer graphics, design and application, man computer interaction. Session (3) goes into the details of the diagnostic examination methods such as digital radiography, MRI, CT, nuclear medicine, ultrasound, digital angiography, and multimodality imaging. Session (4) is devoted to computer-assisted techniques, as there are: computer assisted radiological diagnosis, knowledge based systems, computer assisted radiation therapy and computer assisted surgical planning. (UWA). 266 figs [de

  2. Computer assisted roentgenology

    International Nuclear Information System (INIS)

    Trajkova, N.; Velkova, K.

    1999-01-01

    This is a report on the potentials and superiorities of computer tomography (CT), assumed as an up-to-date imaging examination method in medicine. The current trend in the development of computer assisted roentgenology consists in the implementation of new computer and communication systems promoting diagnostic and therapeutic activities. CT-study application is discussed with special reference to diagnosis and treatment of brain, lung, mediastinal and abdominal diseases. The new trends in the particular implementation of CT are presented, namely: CT-assisted biopsy, CT-assisted abscess drainage, drug administration under CT control, as well as the wide use of CT in orthopaedic surgery, otorinolaryngology etc. Also emphasis is laid on the important role played by three-dimensional technologies in computer-assisted surgery, leading to qualitatively new stage in the surgical therapeutic approach to patients

  3. System control module diagnostic Expert Assistant

    Science.gov (United States)

    Flores, Luis M.; Hansen, Roger F.

    1990-01-01

    The Orbiter EXperiments (OEX) Program was established by NASA's Office of Aeronautics and Space Technology (OAST) to accomplish the precise data collection necessary to support a complete and accurate assessment of Space Transportation System (STS) Orbiter performance during all phases of a mission. During a mission, data generated by the various experiments are conveyed to the OEX System Control Module (SCM) which arranges for and monitors storage of the data on the OEX tape recorder. The SCM Diagnostic Expert Assistant (DEA) is an expert system which provides on demand advice to technicians performing repairs of a malfunctioning SCM. The DEA is a self-contained, data-driven knowledge-based system written in the 'C' Language Production System (CLIPS) for a portable micro-computer of the IBM PC/XT class. The DEA reasons about SCM hardware faults at multiple levels; the most detailed layer of encoded knowledge of the SCM is a representation of individual components and layouts of the custom-designed component boards.

  4. Computer-assisted diagnostic system for neurodegenerative dementia using brain SPECT and 3D-SSP

    International Nuclear Information System (INIS)

    Ishii, Kazunari; Kanda, Tomonori; Uemura, Takafumi; Miyamoto, Naokazu; Yoshikawa, Toshiki; Shimada, Kenichi; Ohkawa, Shingo; Minoshima, Satoshi

    2009-01-01

    To develop a computer-assisted automated diagnostic system to distinguish among Alzheimer disease (AD), dementia with Lewy bodies (DLB), and other degenerative disorders in patients with mild dementia. Single photon emission computed tomography (SPECT) images with injection of N-Isopropyl-p-[ 123 I]iodoamphetamine (IMP) were obtained from patients with mild degenerative dementia. First, datasets from 20 patients mild AD, 15 patients with dementia with DLB, and 17 healthy controls were used to develop an automated diagnosing system based on three-dimensional stereotactic surface projections (3D-SSP). AD- and DLB-specific regional templates were created using 3D-SSP, and critical Z scores in the templates were established. Datasets from 50 AD patients, 8 DLB patients, and 10 patients with non-AD/DLB type degenerative dementia (5 with frontotemporal dementia and 5 with progressive supranuclear palsy) were then used to test the diagnostic accuracy of the optimized automated system in comparison to the diagnostic interpretation of conventional IMP-SPECT images. These comparisons were performed to differentiate AD and DLB from non-AD/DLB and to distinguish AD from DLB. A receiver operating characteristic (ROC) analysis was performed. The area under the ROC curve (Az) and the accuracy of the automated diagnosis system were 0.89 and 82%, respectively, for AD/DLB vs. non-AD/DLB patients, and 0.70 and 65%, respectively, for AD vs. DLB patients. The mean Az and the accuracy of the visual inspection were 0.84 and 77%, respectively, for AD/DLB vs. non-AD/DLB patients, and 0.70 and 65%, respectively, for AD vs. DLB patients. The mean Az and the accuracy of the combination of visual inspection and this system were 0.96 and 91%, respectively, for AD/DLB vs. non-AD/DLB patients, and 0.70 and 66%, respectively, for AD vs. DLB patients. The system developed in the present study achieved as good discrimination of AD, DLB, and other degenerative disorders in patients with mild dementia

  5. Medical image computing for computer-supported diagnostics and therapy. Advances and perspectives.

    Science.gov (United States)

    Handels, H; Ehrhardt, J

    2009-01-01

    Medical image computing has become one of the most challenging fields in medical informatics. In image-based diagnostics of the future software assistance will become more and more important, and image analysis systems integrating advanced image computing methods are needed to extract quantitative image parameters to characterize the state and changes of image structures of interest (e.g. tumors, organs, vessels, bones etc.) in a reproducible and objective way. Furthermore, in the field of software-assisted and navigated surgery medical image computing methods play a key role and have opened up new perspectives for patient treatment. However, further developments are needed to increase the grade of automation, accuracy, reproducibility and robustness. Moreover, the systems developed have to be integrated into the clinical workflow. For the development of advanced image computing systems methods of different scientific fields have to be adapted and used in combination. The principal methodologies in medical image computing are the following: image segmentation, image registration, image analysis for quantification and computer assisted image interpretation, modeling and simulation as well as visualization and virtual reality. Especially, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients and will gain importance in diagnostic and therapy of the future. From a methodical point of view the authors identify the following future trends and perspectives in medical image computing: development of optimized application-specific systems and integration into the clinical workflow, enhanced computational models for image analysis and virtual reality training systems, integration of different image computing methods, further integration of multimodal image data and biosignals and advanced methods for 4D medical image computing. The development of image analysis systems for diagnostic support or

  6. Imaging systems for medical diagnostics

    International Nuclear Information System (INIS)

    Krestel, E.

    1990-01-01

    This book provides physicians and clinical physicists with detailed information on today's imaging modalities and assists them in selecting the optimal system for each clinical application. Physicists, engineers and computer specialists engaged in research and development and sales departments will also find this book to be of considerable use. It may also be employed at universities, training centers and in technical seminars. The physiological and physical fundamentals are explained in part 1. The technical solutions contained in part 2 illustrate the numerous possibilities available in X-ray diagnostics, computed tomography, nuclear medical diagnostics, magnetic resonance imaging, sonography and biomagnetic diagnostics. (orig.)

  7. Oral and maxillofacial surgery with computer-assisted navigation system.

    Science.gov (United States)

    Kawachi, Homare; Kawachi, Yasuyuki; Ikeda, Chihaya; Takagi, Ryo; Katakura, Akira; Shibahara, Takahiko

    2010-01-01

    Intraoperative computer-assisted navigation has gained acceptance in maxillofacial surgery with applications in an increasing number of indications. We adapted a commercially available wireless passive marker system which allows calibration and tracking of virtually every instrument in maxillofacial surgery. Virtual computer-generated anatomical structures are displayed intraoperatively in a semi-immersive head-up display. Continuous observation of the operating field facilitated by computer assistance enables surgical navigation in accordance with the physician's preoperative plans. This case report documents the potential for augmented visualization concepts in surgical resection of tumors in the oral and maxillofacial region. We report a case of T3N2bM0 carcinoma of the maxillary gingival which was surgically resected with the assistance of the Stryker Navigation Cart System. This system was found to be useful in assisting preoperative planning and intraoperative monitoring.

  8. Diagnostic accuracy of commercial system for computer-assisted detection (CADx) as an adjunct to interpretation of mammograms

    International Nuclear Information System (INIS)

    Menna, Sabatino; Di Virgilio, Maria Rosaria; Burke, Paolo; Frigerio, Alfonso; Boglione, Elisa; Ciccarelli, Grazia; Di Filippo, Sabato; Garretti, Licia

    2005-01-01

    Purpose. To evaluate the diagnostic accuracy of the commercial computer-aided detection CADx system for the reading of mammograms. Materials and methods. The study assessed the Second Look system developed and marketed by CADx Medical Systems, Montreal, Canada. The diagnostic sensitivity was evaluated by means of a retrospective study on 98 consecutive cancers detected at screening by double independent reading. The specificity and the positive predictive value (PPV) for cancer of the CADx system were prospectively evaluated on a second group of 560 consecutive mammograms of asymptomatic women not included in screening program. The radiologist who was present during the test assessed the abnormal mammographic findings by one or more of the following diagnostic procedures: physical examination, additional mammographic detail views with or without magnification,ultrasonography, ultrasound- or mammography guided fine needle aspiration cytology, and core-biopsy. The exams first underwent conventional reading and then a second reading carried out with the aid of the CADx system. Results.The overall diagnostic sensitivity of the CADx system on the 98 screening cancers was 81.6%; in particular it was 89.3% for calcifications, 83.9% for masses and only 37.5% for architectural distortion. The CADx markings for each mammography were 4.7 on average. Identification of invasive carcinoma was independent from tumour size. In the second group of 560 mammograms, the CADx system marked all cases identified as positive by conventional reading and confirmed by biopsy (7/7), but did not permit the detection of any additional cancer. The CADx markings per exam were 4.2 on average, the specificity was 13.7% and the PPV was 0.55% versus 13.7% recall rate of conventional reading. CADx reading led to a 1.96% (11/560) increase of the women necessitating further diagnostic investigation. Conclusions. The results of our study show that the diagnostic sensitivity of the CADx system is lower

  9. Computer-assisted design/computer-assisted manufacturing systems: A revolution in restorative dentistry

    Directory of Open Access Journals (Sweden)

    Arbaz Sajjad

    2016-01-01

    Full Text Available For the better part of the past 20 years, dentistry has seen the development of many new all-ceramic materials and restorative techniques fueled by the desire to capture the ever elusive esthetic perfection. This has resulted in the fusion of the latest in material science and the pen ultimate in computer-assisted design/computer-assisted manufacturing (CAD/CAM technology. This case report describes the procedure for restoring the esthetic appearance of both the left and right maxillary peg-shaped lateral incisors with a metal-free sintered finely structured feldspar ceramic material using the latest laboratory CAD/CAM system. The use of CAD/CAM technology makes it possible to produce restorations faster with precision- fit and good esthetics overcoming the errors associated with traditional ceramo-metal technology. The incorporation of this treatment modality would mean that the dentist working procedures will have to be adapted in the methods of CAD/CAM technology.

  10. VIBRO-DIAGNOSTIC SYSTEM ON BASIS OF PERSONAL COMPUTER

    Directory of Open Access Journals (Sweden)

    V. V. Bokut

    2007-01-01

    Full Text Available A system for vibration diagnostics based on a mobile computer and two-channel microprocessor measuring device has been developed. Usage of fast Hartley-Fourier transform allows to increase frequency resolution up to 25000 spectral lines that makes it possible to use the system for wide range of applications. 

  11. Computer-assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.

    1988-01-01

    New digital imaging modalities and more sophisticated image processing systems will have a profound effect on those areas of medicine concerned with imaging. This mainly means computer-assisted radiology (CAR) and implies a transition from analog film systems to digital imaging systems, integration of digital imaging modalities through picture archiving and communication systems (PACS) and the graduated employment of image-oriented medical work stations (MWS) for computer-assisted representation, communication, diagnosis, and therapy planning. (orig.) [de

  12. 76 FR 71980 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... SEDASYS computer-assisted personalized sedation system (SEDASYS) submitted by Ethicon Endo-Surgery Inc...

  13. Computer-assisted learning and simulation systems in dentistry--a challenge to society.

    Science.gov (United States)

    Welk, A; Splieth, Ch; Wierinck, E; Gilpatrick, R O; Meyer, G

    2006-07-01

    Computer technology is increasingly used in practical training at universities. However, in spite of their potential, computer-assisted learning (CAL) and computer-assisted simulation (CAS) systems still appear to be underutilized in dental education. Advantages, challenges, problems, and solutions of computer-assisted learning and simulation in dentistry are discussed by means of MEDLINE, open Internet platform searches, and key results of a study among German dental schools. The advantages of computer-assisted learning are seen for example in self-paced and self-directed learning and increased motivation. It is useful for both objective theoretical and practical tests and for training students to handle complex cases. CAL can lead to more structured learning and can support training in evidence-based decision-making. The reasons for the still relatively rare implementation of CAL/CAS systems in dental education include an inability to finance, lack of studies of CAL/CAS, and too much effort required to integrate CAL/CAS systems into the curriculum. To overcome the reasons for the relative low degree of computer technology use, we should strive for multicenter research and development projects monitored by the appropriate national and international scientific societies, so that the potential of computer technology can be fully realized in graduate, postgraduate, and continuing dental education.

  14. Application Of The CSRL Language To The Design Of Diagnostic Expert Systems: The Moodis Experience, A Preliminary Report

    Science.gov (United States)

    Bravos, Angelo; Hill, Howard; Choca, James; Bresolin, Linda B.; Bresolin, Michael J.

    1986-03-01

    Computer technology is rapidly becoming an inseparable part of many health science specialties. Recently, a new area of computer technology, namely Artificial Intelligence, has been applied toward assisting the medical experts in their diagnostic and therapeutic decision making process. MOODIS is an experimental diagnostic expert system which assists Psychiatry specialists in diagnosing human Mood Disorders, better known as Affective Disorders. Its diagnostic methodology is patterned after MDX, a diagnostic expert system developed at LAIR (Laboratory for Artificial Intelligence Research) of Ohio State University. MOODIS is implemented in CSRL (Conceptual Structures Representation Language) also developed at LAIR. This paper describes MOODIS in terms of conceptualization and requirements, and discusses why the MDX approach and CSRL were chosen.

  15. Diagnostic performance of a computer-assisted diagnosis system for bone scintigraphy of newly developed skeletal metastasis in prostate cancer patients: search for low-sensitivity subgroups.

    Science.gov (United States)

    Koizumi, Mitsuru; Motegi, Kazuki; Koyama, Masamichi; Terauchi, Takashi; Yuasa, Takeshi; Yonese, Junji

    2017-08-01

    The computer-assisted diagnostic system for bone scintigraphy (BS) BONENAVI is used to evaluate skeletal metastasis. We investigated its diagnostic performance in prostate cancer patients with and without skeletal metastasis and searched for the problems. An artificial neural network (ANN) value was calculated in 226 prostate cancer patients (124 with skeletal metastasis and 101 without) using BS. Receiver operating characteristic curve analysis was performed and the sensitivity and specificity determined (cutoff ANN = 0.5). Patient's situation at the time of diagnosis of skeletal metastasis, computed tomography (CT) type, extent of disease (EOD), and BS uptake grade were analyzed. False-negative and false-positive results were recorded. BONENAVI showed 82% (102/124) of sensitivity and 83% (84/101) specificity for metastasis detection. There were no significant differences among CT types, although low EOD and faint BS uptake were associated with low ANN values and low sensitivity. Patients showed lower sensitivity during the follow-up period than staging work-up. False-negative lesions were often located in the pelvis or adjacent to it. They comprised not only solitary, faint BS lesions but also overlaying to urinary excretion. BONENAVI with BS has good sensitivity and specificity for detecting prostate cancer's osseous metastasis. Low EOD and faint BS uptake are associated with low sensitivity but not the CT type. Prostate cancer patients likely to have false-negative results during the follow-up period had a solitary lesion in the pelvis with faint BS uptake or lesions overlaying to urinary excretion.

  16. Computer-assisted enzyme immunoassays and simplified immunofluorescence assays: applications for the diagnostic laboratory and the veterinarian's office.

    Science.gov (United States)

    Jacobson, R H; Downing, D R; Lynch, T J

    1982-11-15

    A computer-assisted enzyme-linked immunosorbent assay (ELISA) system, based on kinetics of the reaction between substrate and enzyme molecules, was developed for testing large numbers of sera in laboratory applications. Systematic and random errors associated with conventional ELISA technique were identified leading to results formulated on a statistically validated, objective, and standardized basis. In a parallel development, an inexpensive system for field and veterinary office applications contained many of the qualities of the computer-assisted ELISA. This system uses a fluorogenic indicator (rather than the enzyme-substrate interaction) in a rapid test (15 to 20 minutes' duration) which promises broad application in serodiagnosis.

  17. Assisted supervision of a computer aided tele-operation system

    Energy Technology Data Exchange (ETDEWEB)

    Le Bars, H; Gravez, P; Fournier, R

    1994-12-31

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs.

  18. Assisted supervision of a computer aided tele-operation system

    International Nuclear Information System (INIS)

    Le Bars, H.; Gravez, P.; Fournier, R.

    1994-01-01

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs

  19. Towards ubiquitous access of computer-assisted surgery systems.

    Science.gov (United States)

    Liu, Hui; Lufei, Hanping; Shi, Weishong; Chaudhary, Vipin

    2006-01-01

    Traditional stand-alone computer-assisted surgery (CAS) systems impede the ubiquitous and simultaneous access by multiple users. With advances in computing and networking technologies, ubiquitous access to CAS systems becomes possible and promising. Based on our preliminary work, CASMIL, a stand-alone CAS server developed at Wayne State University, we propose a novel mobile CAS system, UbiCAS, which allows surgeons to retrieve, review and interpret multimodal medical images, and to perform some critical neurosurgical procedures on heterogeneous devices from anywhere at anytime. Furthermore, various optimization techniques, including caching, prefetching, pseudo-streaming-model, and compression, are used to guarantee the QoS of the UbiCAS system. UbiCAS enables doctors at remote locations to actively participate remote surgeries, share patient information in real time before, during, and after the surgery.

  20. EAST-AIA deployment under vacuum: Calibration of laser diagnostic system using computer vision

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang, E-mail: yangyang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Song, Yuntao; Cheng, Yong; Feng, Hansheng; Wu, Zhenwei; Li, Yingying; Sun, Yongjun; Zheng, Lei [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Bruno, Vincent; Eric, Villedieu [CEA-IRFM, F-13108 Saint-Paul-Lez-Durance (France)

    2016-11-15

    Highlights: • The first deployment of the EAST articulated inspection arm robot under vacuum is presented. • A computer vision based approach to measure the laser spot displacement is proposed. • An experiment on the real EAST tokamak is performed to validate the proposed measure approach, and the results shows that the measurement accuracy satisfies the requirement. - Abstract: For the operation of EAST tokamak, it is crucial to ensure that all the diagnostic systems are in the good condition in order to reflect the plasma status properly. However, most of the diagnostic systems are mounted inside the tokamak vacuum vessel, which makes them extremely difficult to maintain under high vacuum condition during the tokamak operation. Thanks to a system called EAST articulated inspection arm robot (EAST-AIA), the examination of these in-vessel diagnostic systems can be performed by an embedded camera carried by the robot. In this paper, a computer vision algorithm has been developed to calibrate a laser diagnostic system with the help of a monocular camera at the robot end. In order to estimate the displacement of the laser diagnostic system with respect to the vacuum vessel, several visual markers were attached to the inner wall. This experiment was conducted both on the EAST vacuum vessel mock-up and the real EAST tokamak under vacuum condition. As a result, the accuracy of the displacement measurement was within 3 mm under the current camera resolution, which satisfied the laser diagnostic system calibration.

  1. Instrumental tactile diagnostics in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Solodova RF

    2016-10-01

    Full Text Available Rozalia F Solodova,1,2 Vladimir V Galatenko,1,2 Eldar R Nakashidze,3 Igor L Andreytsev,3 Alexey V Galatenko,1 Dmitriy K Senchik,2 Vladimir M Staroverov,1 Vladimir E Podolskii,1,2 Mikhail E Sokolov,1,2 Victor A Sadovnichy1,2 1Faculty of Mechanics and Mathematics, 2Institute of Mathematical Studies of Complex Systems, Lomonosov Moscow State University, 31st Surgery Department, Clinical Hospital 31, Moscow, Russia Background: Robotic surgery has gained wide acceptance due to minimizing trauma in patients. However, the lack of tactile feedback is an essential limiting factor for the further expansion. In robotic surgery, feedback related to touch is currently kinesthetic, and it is mainly aimed at the minimization of force applied to tissues and organs. Design and implementation of diagnostic tactile feedback is still an open problem. We hypothesized that a sufficient tactile feedback in robot-assisted surgery can be provided by utilization of Medical Tactile Endosurgical Complex (MTEC, which is a novel specialized tool that is already commercially available in the Russian Federation. MTEC allows registration of tactile images by a mechanoreceptor, real-time visualization of these images, and reproduction of images via a tactile display. Materials and methods: Nine elective surgeries were performed with da Vinci™ robotic system. An assistant performed tactile examination through an additional port under the guidance of a surgeon during revision of tissues. The operating surgeon sensed registered tactile data using a tactile display, and the assistant inspected the visualization of tactile data. First, surgeries where lesion boundaries were visually detectable were performed. The goal was to promote cooperation between the surgeon and the assistant and to train them in perception of the tactile feedback. Then, instrumental tactile diagnostics was utilized in case of visually undetectable boundaries. Results: In robot-assisted surgeries where lesion

  2. A systematic review of computer-assisted diagnosis in diagnostic cancer imaging

    International Nuclear Information System (INIS)

    Eadie, Leila H.; Taylor, Paul; Gibson, Adam P.

    2012-01-01

    Objectives: This study reviews the evidence for the effectiveness of computer-assisted diagnosis (CAD) in cancer imaging. Diagnostic applications were studied to estimate the impact of CAD on radiologists’ detection and diagnosis of cancer lesions. Methods: Online databases were searched and 48 studies from 1992 to 2010 were included: 16 with radiologists using CAD to detect lesions (CADe) and 32 with radiologists using CAD to classify or diagnose lesions (CADx). Weighted means, statistics, summary receiver operating characteristics (SROC) curves, and related measures were used for analysis. Results: There is evidence that CADx significantly improves diagnosis in mammography and breast ultrasound. In contrast, studies of CADx applied to lung CT and dermatologic imaging show an adverse impact on diagnosis. Overall, there is no evidence of a benefit due to the use of CADe. The area under the SROC curves was not significantly increased for radiologists using either CADe or CADx. Conclusions: From this analysis it seems CADx can offer some benefit to radiologists in specific imaging applications for breast cancer diagnosis. There is no evidence of a beneficial effect in other applications of CAD and some evidence of a detrimental one.

  3. System for simulating fluctuation diagnostics for application to turbulence computations

    International Nuclear Information System (INIS)

    Bravenec, R.V.; Nevins, W.M.

    2006-01-01

    Present-day nonlinear microstability codes are able to compute the saturated fluctuations of a turbulent fluid versus space and time, whether the fluid be liquid, gas, or plasma. They are therefore able to determine turbulence-induced fluid (or particle) and energy fluxes. These codes, however, must be tested against experimental data not only with respect to transport but also characteristics of the fluctuations. The latter is challenging because of limitations in the diagnostics (e.g., finite spatial resolution) and the fact that the diagnostics typically do not measure exactly the quantities that the codes compute. In this work, we present a system based on IDL registered analysis and visualization software in which user-supplied 'diagnostic filters' are applied to the code outputs to generate simulated diagnostic signals. The same analysis techniques as applied to the measurements, e.g., digital time-series analysis, may then be applied to the synthesized signals. Their statistical properties, such as rms fluctuation level, mean wave numbers, phase and group velocities, correlation lengths and times, and in some cases full S(k,ω) spectra, can then be compared directly to those of the measurements

  4. Seventh Medical Image Computing and Computer Assisted Intervention Conference (MICCAI 2012)

    CERN Document Server

    Miller, Karol; Nielsen, Poul; Computational Biomechanics for Medicine : Models, Algorithms and Implementation

    2013-01-01

    One of the greatest challenges for mechanical engineers is to extend the success of computational mechanics to fields outside traditional engineering, in particular to biology, biomedical sciences, and medicine. This book is an opportunity for computational biomechanics specialists to present and exchange opinions on the opportunities of applying their techniques to computer-integrated medicine. Computational Biomechanics for Medicine: Models, Algorithms and Implementation collects the papers from the Seventh Computational Biomechanics for Medicine Workshop held in Nice in conjunction with the Medical Image Computing and Computer Assisted Intervention conference. The topics covered include: medical image analysis, image-guided surgery, surgical simulation, surgical intervention planning, disease prognosis and diagnostics, injury mechanism analysis, implant and prostheses design, and medical robotics.

  5. Computer-Assisted Classification Patterns in Autoimmune Diagnostics: The AIDA Project

    Directory of Open Access Journals (Sweden)

    Amel Benammar Elgaaied

    2016-01-01

    Full Text Available Antinuclear antibodies (ANAs are significant biomarkers in the diagnosis of autoimmune diseases in humans, done by mean of Indirect ImmunoFluorescence (IIF method, and performed by analyzing patterns and fluorescence intensity. This paper introduces the AIDA Project (autoimmunity: diagnosis assisted by computer developed in the framework of an Italy-Tunisia cross-border cooperation and its preliminary results. A database of interpreted IIF images is being collected through the exchange of images and double reporting and a Gold Standard database, containing around 1000 double reported images, has been settled. The Gold Standard database is used for optimization of a CAD (Computer Aided Detection solution and for the assessment of its added value, in order to be applied along with an Immunologist as a second Reader in detection of autoantibodies. This CAD system is able to identify on IIF images the fluorescence intensity and the fluorescence pattern. Preliminary results show that CAD, used as second Reader, appeared to perform better than Junior Immunologists and hence may significantly improve their efficacy; compared with two Junior Immunologists, the CAD system showed higher Intensity Accuracy (85,5% versus 66,0% and 66,0%, higher Patterns Accuracy (79,3% versus 48,0% and 66,2%, and higher Mean Class Accuracy (79,4% versus 56,7% and 64.2%.

  6. Computer-Assisted Classification Patterns in Autoimmune Diagnostics: The AIDA Project.

    Science.gov (United States)

    Benammar Elgaaied, Amel; Cascio, Donato; Bruno, Salvatore; Ciaccio, Maria Cristina; Cipolla, Marco; Fauci, Alessandro; Morgante, Rossella; Taormina, Vincenzo; Gorgi, Yousr; Marrakchi Triki, Raja; Ben Ahmed, Melika; Louzir, Hechmi; Yalaoui, Sadok; Imene, Sfar; Issaoui, Yassine; Abidi, Ahmed; Ammar, Myriam; Bedhiafi, Walid; Ben Fraj, Oussama; Bouhaha, Rym; Hamdi, Khouloud; Soumaya, Koudhi; Neili, Bilel; Asma, Gati; Lucchese, Mariano; Catanzaro, Maria; Barbara, Vincenza; Brusca, Ignazio; Fregapane, Maria; Amato, Gaetano; Friscia, Giuseppe; Neila, Trai; Turkia, Souayeh; Youssra, Haouami; Rekik, Raja; Bouokez, Hayet; Vasile Simone, Maria; Fauci, Francesco; Raso, Giuseppe

    2016-01-01

    Antinuclear antibodies (ANAs) are significant biomarkers in the diagnosis of autoimmune diseases in humans, done by mean of Indirect ImmunoFluorescence (IIF) method, and performed by analyzing patterns and fluorescence intensity. This paper introduces the AIDA Project (autoimmunity: diagnosis assisted by computer) developed in the framework of an Italy-Tunisia cross-border cooperation and its preliminary results. A database of interpreted IIF images is being collected through the exchange of images and double reporting and a Gold Standard database, containing around 1000 double reported images, has been settled. The Gold Standard database is used for optimization of a CAD (Computer Aided Detection) solution and for the assessment of its added value, in order to be applied along with an Immunologist as a second Reader in detection of autoantibodies. This CAD system is able to identify on IIF images the fluorescence intensity and the fluorescence pattern. Preliminary results show that CAD, used as second Reader, appeared to perform better than Junior Immunologists and hence may significantly improve their efficacy; compared with two Junior Immunologists, the CAD system showed higher Intensity Accuracy (85,5% versus 66,0% and 66,0%), higher Patterns Accuracy (79,3% versus 48,0% and 66,2%), and higher Mean Class Accuracy (79,4% versus 56,7% and 64.2%).

  7. Computer-Assisted Classification Patterns in Autoimmune Diagnostics: The AIDA Project

    Science.gov (United States)

    Benammar Elgaaied, Amel; Cascio, Donato; Bruno, Salvatore; Ciaccio, Maria Cristina; Cipolla, Marco; Fauci, Alessandro; Morgante, Rossella; Taormina, Vincenzo; Gorgi, Yousr; Marrakchi Triki, Raja; Ben Ahmed, Melika; Louzir, Hechmi; Yalaoui, Sadok; Imene, Sfar; Issaoui, Yassine; Abidi, Ahmed; Ammar, Myriam; Bedhiafi, Walid; Ben Fraj, Oussama; Bouhaha, Rym; Hamdi, Khouloud; Soumaya, Koudhi; Neili, Bilel; Asma, Gati; Lucchese, Mariano; Catanzaro, Maria; Barbara, Vincenza; Brusca, Ignazio; Fregapane, Maria; Amato, Gaetano; Friscia, Giuseppe; Neila, Trai; Turkia, Souayeh; Youssra, Haouami; Rekik, Raja; Bouokez, Hayet; Vasile Simone, Maria; Fauci, Francesco; Raso, Giuseppe

    2016-01-01

    Antinuclear antibodies (ANAs) are significant biomarkers in the diagnosis of autoimmune diseases in humans, done by mean of Indirect ImmunoFluorescence (IIF) method, and performed by analyzing patterns and fluorescence intensity. This paper introduces the AIDA Project (autoimmunity: diagnosis assisted by computer) developed in the framework of an Italy-Tunisia cross-border cooperation and its preliminary results. A database of interpreted IIF images is being collected through the exchange of images and double reporting and a Gold Standard database, containing around 1000 double reported images, has been settled. The Gold Standard database is used for optimization of a CAD (Computer Aided Detection) solution and for the assessment of its added value, in order to be applied along with an Immunologist as a second Reader in detection of autoantibodies. This CAD system is able to identify on IIF images the fluorescence intensity and the fluorescence pattern. Preliminary results show that CAD, used as second Reader, appeared to perform better than Junior Immunologists and hence may significantly improve their efficacy; compared with two Junior Immunologists, the CAD system showed higher Intensity Accuracy (85,5% versus 66,0% and 66,0%), higher Patterns Accuracy (79,3% versus 48,0% and 66,2%), and higher Mean Class Accuracy (79,4% versus 56,7% and 64.2%). PMID:27042658

  8. Computer-assisted assessment of ultrasound real-time elastography: initial experience in 145 breast lesions.

    Science.gov (United States)

    Zhang, Xue; Xiao, Yang; Zeng, Jie; Qiu, Weibao; Qian, Ming; Wang, Congzhi; Zheng, Rongqin; Zheng, Hairong

    2014-01-01

    To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (Az value) for the proposed method was higher than the Az value for visual assessment (0.96 vs. 0.93). Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Computer-assisted assessment of ultrasound real-time elastography: Initial experience in 145 breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xue; Xiao, Yang [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Zeng, Jie [Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou (China); Qiu, Weibao; Qian, Ming; Wang, Congzhi [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Zheng, Rongqin, E-mail: zhengronggin@hotmail.com [Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou (China); Zheng, Hairong, E-mail: hr.zheng@siat.ac.cn [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China)

    2014-01-15

    Purpose: To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Materials and methods: Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Results: Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (A{sub z} value) for the proposed method was higher than the A{sub z} value for visual assessment (0.96 vs. 0.93). Conclusion: Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy.

  10. An Intelligent Computer Assisted Language Learning System for Arabic Learners

    Science.gov (United States)

    Shaalan, Khaled F.

    2005-01-01

    This paper describes the development of an intelligent computer-assisted language learning (ICALL) system for learning Arabic. This system could be used for learning Arabic by students at primary schools or by learners of Arabic as a second or foreign language. It explores the use of Natural Language Processing (NLP) techniques for learning…

  11. Computer-Assisted Career Guidance Systems: A Part of NCDA History

    Science.gov (United States)

    Harris-Bowlsbey, JoAnn

    2013-01-01

    The first computer-assisted career planning systems were developed in the late 1960s and were based soundly on the best of career development and decision-making theory. Over the years, this tradition has continued as the technology that delivers these systems' content has improved dramatically and as they have been universally accepted as…

  12. Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems

    Science.gov (United States)

    2017-04-13

    AFRL-AFOSR-UK-TR-2017-0029 Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems ...2012, “ Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems .” 2. The objective...2012 - 01/25/2015 4. TITLE AND SUBTITLE Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous

  13. Computer assisted diagnosis of benign bone tumours

    International Nuclear Information System (INIS)

    Samardziski, M.; Zafiroski, G.; Janevska, V.; Miladinova, D.; Popeska, Z.

    2004-01-01

    Background. The aim of this study is to determine the correlation between computer-assisted diagnosis (CAD) of benign bone tumours (BBT) and their histological type. Patients and method. Altogether 120 patients were included in two groups. The retrospective group comprised 68 patients in whom the histological type of BBT was known prior to computer analysis. The prospective group comprised 52 patients in whom the histological type of BBT was unknown prior to computer analysis. Computer program was efficient and easy to use. Results. Average percent of histological type confirmed with CAD in the retrospective and prospective groups was 72.06% and 76.92%, respectively. Histological confirmation of CAD in specific BBT was 91.42% for enchondroma, 96.15% for osteoid-osteoma, and 98.08% for osteochondroma. Significantly lower percentage of CAD confirmation of fibroma, chondromixoid fibroma, osteoclastoma, desmoplastic fibroma and osteobalstoma due to their adverse biological character or complex anatomic localization is understandable. Conclusions. The results speak in favour of the assumption that computer assisted diagnosis of bone tumours program may improve the diagnostic accuracy of the examiner. (author)

  14. Computer-Assisted English Learning System Based on Free Conversation by Topic

    Science.gov (United States)

    Choi, Sung-Kwon; Kwon, Oh-Woog; Kim, Young-Kil

    2017-01-01

    This paper aims to describe a computer-assisted English learning system using chatbots and dialogue systems, which allow free conversation outside the topic without limiting the learner's flow of conversation. The evaluation was conducted by 20 experimenters. The performance of the system based on a free conversation by topic was measured by the…

  15. New Computer Assisted Diagnostic to Detect Alzheimer Disease

    Directory of Open Access Journals (Sweden)

    Ben Rabeh Amira

    2016-08-01

    Full Text Available We describe a new Computer Assisted Diagnosis (CAD to automatically detect Alzheimer Patients (AD, Mild Cognitive Impairment (MCI and elderly Controls, based on the segmentation and classification of the Hippocampus (H and Corpus Calosum (CC from Magnetic Resonance Images (MRI. For the segmentation we used a new method based on a deformable model to extract the area wishes, and then we computed the geometric and texture features. For the classification we proposed a new supervised method. We evaluated the accuracy of our method in a group of 25 patients with AD (age±standard-deviation (SD =70±6 years, 25 patients with MCI (age±SD=65±8 years and 25 elderly healthy controls (age±SD=60±8 years. For the AD patients we found an accuracy of the classification of 92%, for the MCI we found 88% and for the elderly patients we found 96%. Overall, we found our method to be 92% accurate. Our method can be a useful tool for diagnosing Alzheimer’s Disease in any of these Steps.

  16. Computer assisted pyeloplasty in children the retroperitoneal approach

    DEFF Research Database (Denmark)

    Olsen, L H; Jorgensen, T M

    2004-01-01

    PURPOSE: We describe the first series of computer assisted retroperitoneoscopic pyeloplasty in children using the Da Vinci Surgical System (Intuitive Surgical, Inc., Mountainview, California) with regard to setup, method, operation time, complications and preliminary outcome. The small space...... with the Da Vinci Surgical System. With the patient in a lateral semiprone position the retroperitoneal space was developed by blunt and balloon dissection. Three ports were placed for the computer assisted system and 1 for assistance. Pyeloplasty was performed with the mounted system placed behind...

  17. A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure.

    Science.gov (United States)

    Lützen, Ulf; Naumann, Carsten Maik; Marx, Marlies; Zhao, Yi; Jüptner, Michael; Baumann, René; Papp, László; Zsótér, Norbert; Aksenov, Alexey; Jünemann, Klaus-Peter; Zuhayra, Maaz

    2016-09-07

    Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial

  18. Pathology Assistant (C - Gamechanger Of Pathology Diagnostic

    Directory of Open Access Journals (Sweden)

    Asel Kudaybergenova

    2016-06-01

    When the competition ended, we received many favor- able reviews and we decided to start another project a little bit similar to the competition. Every month we show three interesting and difficult to diagnose cases provided by the leading Russian pathologists. The participants can look through the clinical data and digitized histological slides, and then discuss what they see among their professional society. There are 400  specialists  from  post  USSR countries.  Moreover, we get a few proposal of partnership to start a similar project in EU. And the last product in line is Pathology Assistant. It is a game changer. Pathology Assistant is a Digital Pathology©technology driven application for pathology diagnostics, tool to innovate pathology diagnostics in more simple, proven by analytical algo- rithm, automatically delivering anticipated support way. The service provides vast and structured database of validated cases, intuitive interface, fast and convenient system of analytical search. Pathology Assistant will streamline and simplify pathologist’s way to the right decision. Pathologists from Memorial Sloan Catering and biggest EU labs are working on preparing the con- tent for the project.  

  19. Surface Modeling, Solid Modeling and Finite Element Modeling. Analysis Capabilities of Computer-Assisted Design and Manufacturing Systems.

    Science.gov (United States)

    Nee, John G.; Kare, Audhut P.

    1987-01-01

    Explores several concepts in computer assisted design/computer assisted manufacturing (CAD/CAM). Defines, evaluates, reviews and compares advanced computer-aided geometric modeling and analysis techniques. Presents the results of a survey to establish the capabilities of minicomputer based-systems with the CAD/CAM packages evaluated. (CW)

  20. Computer-assisted education system for arrhythmia (CAESAR).

    Science.gov (United States)

    Fukushima, M; Inoue, M; Fukunami, M; Ishikawa, K; Inada, H; Abe, H

    1984-08-01

    A computer-assisted education system for arrhythmia (CAESAR) was developed for students to acquire the ability to logically diagnose complicated arrhythmias. This system has a logical simulator of cardiac rhythm using a mathematical model of the impulse formation and conduction system of the heart. A simulated arrhythmia (ECG pattern) is given on a graphic display unit with simulated series of the action potential of five pacemaker centers and the "ladder diagram" of impulse formation and conduction, which show the mechanism of that arrhythmia. For the purpose of the evaluation of this system, 13 medical students were given two types of tests concerning arrhythmias before and after 2-hr learning with this system. The scores they obtained after learning increased significantly from 73.3 +/- 11.9 to 93.2 +/- 3.0 (P less than 0.001) in one test and from 47.2 +/- 17.9 to 64.9 +/- 19.6 (P less than 0.001) in another one. These results proved that this CAI system is useful and effective for training ECG interpretation of arrhythmias.

  1. Vi-da: vitiligo diagnostic assistance mobile application

    Science.gov (United States)

    Nugraha, G. A.; Nurhudatiana, A.; Bahana, R.

    2018-03-01

    Vitiligo is a skin disorder in which white patches of depigmentation appear on different parts of the body. Usually, patients come to hospitals or clinics to have their vitiligo conditions assessed. This can be very tiring to the patients, as vitiligo treatments usually take a relatively long period of time, which can range from months to years. To address this challenge, we present in this paper a prototype of an Android-based mobile application called Vi-DA, which stands for Vitiligo Diagnostic Assistance. Vi-DA consists of three subsystems, which are user sign-up subsystem, camera and image analysis subsystem, and progress report subsystem. The mobile application was developed in Java programming language and uses MySQL as the database system. Vi-DA adopts a vitiligo segmentation algorithm to segment input image into normal skin area, vitiligo skin area, and non-skin area. Results showed that Vi-DA gave comparable results to the previous system implemented in Matlab. User acceptance testing results also showed that all respondents agreed on the usefulness of the system and agreed to use Vi-DA again in the future. Vi-DA benefits both dermatologists and patients as not only a computer-aided diagnosis (CAD) tool but also as a smart application that can be used for self-assessment at home.

  2. COMPUTER-ASSISTED ACCOUNTING

    Directory of Open Access Journals (Sweden)

    SORIN-CIPRIAN TEIUŞAN

    2009-01-01

    Full Text Available What is computer-assisted accounting? Where is the place and what is the role of the computer in the financial-accounting activity? What is the position and importance of the computer in the accountant’s activity? All these are questions that require scientific research in order to find the answers. The paper approaches the issue of the support granted to the accountant to organize and manage the accounting activity by the computer. Starting from the notions of accounting and computer, the concept of computer-assisted accounting is introduced, it has a general character and it refers to the accounting performed with the help of the computer or using the computer to automate the procedures performed by the person who is doing the accounting activity; this is a concept used to define the computer applications of the accounting activity. The arguments regarding the use of the computer to assist accounting targets the accounting informatization, the automating of the financial-accounting activities and the endowment with modern technology of the contemporary accounting.

  3. [Basic concept in computer assisted surgery].

    Science.gov (United States)

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  4. Computer-assisted diagnosis of melanoma.

    Science.gov (United States)

    Fuller, Collin; Cellura, A Paul; Hibler, Brian P; Burris, Katy

    2016-03-01

    The computer-assisted diagnosis of melanoma is an exciting area of research where imaging techniques are combined with diagnostic algorithms in an attempt to improve detection and outcomes for patients with skin lesions suspicious for malignancy. Once an image has been acquired, it undergoes a processing pathway which includes preprocessing, enhancement, segmentation, feature extraction, feature selection, change detection, and ultimately classification. Practicality for everyday clinical use remains a vital question. A successful model must obtain results that are on par or outperform experienced dermatologists, keep costs at a minimum, be user-friendly, and be time efficient with high sensitivity and specificity. ©2015 Frontline Medical Communications.

  5. Beam Diagnostics Systems for the National Ignition Facility

    International Nuclear Information System (INIS)

    Demaret, R D; Boyd, R D; Bliss, E S; Gates, A J; Severyn, J R

    2001-01-01

    The National Ignition Facility (NIF) laser focuses 1.8 megajoules of ultraviolet light (wavelength 351 nanometers) from 192 beams into a 600-micrometer-diameter volume. Effective use of this output in target experiments requires that the power output from all of the beams match within 8% over their entire 20-nanosecond waveform. The scope of NIF beam diagnostics systems necessary to accomplish this task is unprecedented for laser facilities. Each beamline contains 110 major optical components distributed over a 510-meter path, and diagnostic tolerances for beam measurement are demanding. Total laser pulse energy is measured with 2.8% precision, and the interbeam temporal variation of pulse power is measured with 4% precision. These measurement goals are achieved through use of approximately 160 sensor packages that measure the energy at five locations and power at three locations along each beamline using 335 photodiodes, 215 calorimeters, and 36 digitizers. Successful operation of such a system requires a high level of automation of the widely distributed sensors. Computer control systems provide the basis for operating the shot diagnostics with repeatable accuracy, assisted by operators who oversee system activities and setup, respond to performance exceptions, and complete calibration and maintenance tasks

  6. 76 FR 75887 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-12-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... system (SEDASYS) submitted by Ethicon Endo-Surgery Inc. (EES), the sponsor for SEDASYS. This meeting has...

  7. Effects of computer-assisted oral anticoagulant therapy

    DEFF Research Database (Denmark)

    Rasmussen, Rune Skovgaard; Corell, Pernille; Madsen, Poul

    2012-01-01

    : Patients randomized to computer-assisted anticoagulation and the CoaguChek® system reached the therapeutic target range after 8 days compared to 14 days by prescriptions from physicians (p = 0.04). Time spent in the therapeutic target range did not differ between groups. The median INR value measured...... prescribed by physicians, and the total time spent within the therapeutic target range was similar. Thus computer-assisted oral anticoagulant therapy may reduce the cost of anticoagulation therapy without lowering the quality. INR values measured by CoaguChek® were reliable compared to measurements......UNLABELLED: BACKGROUND: Computer-assistance and self-monitoring lower the cost and may improve the quality of anticoagulation therapy. The main purpose of this clinical investigation was to use computer-assisted oral anticoagulant therapy to improve the time to reach and the time spent within...

  8. Computer assisted radiology and surgery. CARS 2010

    International Nuclear Information System (INIS)

    Anon.

    2010-01-01

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  9. Computer assisted radiology and surgery. CARS 2010

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-06-15

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  10. Design and Study of a Next-Generation Computer-Assisted System for Transoral Laser Microsurgery

    Directory of Open Access Journals (Sweden)

    Nikhil Deshpande PhD

    2018-05-01

    Full Text Available Objective To present a new computer-assisted system for improved usability, intuitiveness, efficiency, and controllability in transoral laser microsurgery (TLM. Study Design Pilot technology feasibility study. Setting A dedicated room with a simulated TLM surgical setup: surgical microscope, surgical laser system, instruments, ex vivo pig larynxes, and computer-assisted system. Subjects and Methods The computer-assisted laser microsurgery (CALM system consists of a novel motorized laser micromanipulator and a tablet- and stylus-based control interface. The system setup includes the Leica 2 surgical microscope and the DEKA HiScan Surgical laser system. The system was validated through a first-of-its-kind observational study with 57 international surgeons with varied experience in TLM. The subjects performed real surgical tasks on ex vivo pig larynxes in a simulated TLM scenario. The qualitative aspects were established with a newly devised questionnaire assessing the usability, efficiency, and suitability of the system. Results The surgeons evaluated the CALM system with an average score of 6.29 (out of 7 in ease of use and ease of learning, while an average score of 5.96 was assigned for controllability and safety. A score of 1.51 indicated reduced workload for the subjects. Of 57 subjects, 41 stated that the CALM system allows better surgical quality than the existing TLM systems. Conclusions The CALM system augments the usability, controllability, and efficiency in TLM. It enhances the ergonomics and accuracy beyond the current state of the art, potentially improving the surgical safety and quality. The system offers the intraoperative automated scanning of customized long incisions achieving uniform resections at the surgical site.

  11. Intelligent Diagnostic Assistant for Complicated Skin Diseases through C5's Algorithm.

    Science.gov (United States)

    Jeddi, Fatemeh Rangraz; Arabfard, Masoud; Kermany, Zahra Arab

    2017-09-01

    Intelligent Diagnostic Assistant can be used for complicated diagnosis of skin diseases, which are among the most common causes of disability. The aim of this study was to design and implement a computerized intelligent diagnostic assistant for complicated skin diseases through C5's Algorithm. An applied-developmental study was done in 2015. Knowledge base was developed based on interviews with dermatologists through questionnaires and checklists. Knowledge representation was obtained from the train data in the database using Excel Microsoft Office. Clementine Software and C5's Algorithms were applied to draw the decision tree. Analysis of test accuracy was performed based on rules extracted using inference chains. The rules extracted from the decision tree were entered into the CLIPS programming environment and the intelligent diagnostic assistant was designed then. The rules were defined using forward chaining inference technique and were entered into Clips programming environment as RULE. The accuracy and error rates obtained in the training phase from the decision tree were 99.56% and 0.44%, respectively. The accuracy of the decision tree was 98% and the error was 2% in the test phase. Intelligent diagnostic assistant can be used as a reliable system with high accuracy, sensitivity, specificity, and agreement.

  12. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  13. Using a Dialogue System Based on Dialogue Maps for Computer Assisted Second Language Learning

    Science.gov (United States)

    Choi, Sung-Kwon; Kwon, Oh-Woog; Kim, Young-Kil; Lee, Yunkeun

    2016-01-01

    In order to use dialogue systems for computer assisted second-language learning systems, one of the difficult issues in such systems is how to construct large-scale dialogue knowledge that matches the dialogue modelling of a dialogue system. This paper describes how we have accomplished the short-term construction of large-scale and…

  14. Balloon-assisted enteroscopy for suspected Meckel’s diverticulum and indefinite diagnostic imaging workup

    Science.gov (United States)

    Gomes, Guilherme Francisco; Bonin, Eduardo Aimore; Noda, Rafael William; Cavazzola, Leandro Totti; Bartholomei, Thiago Ferreira

    2016-01-01

    Meckel’s diverticulum (MD) is estimated to affect 1%-2% of the general population, and it represents a clinically silent finding of a congenital anomaly in up to 85% of the cases. In adults, MD may cause symptoms, such as overt occult lower gastrointestinal bleeding. The diagnostic imaging workup includes computed tomography scan, magnetic resonance imaging enterography, technetium 99m scintigraphy (99mTc) using either labeled red blood cells or pertechnetate (known as the Meckel’s scan) and angiography. The preoperative detection rate of MD in adults is low, and many patients ultimately undergo exploratory laparoscopy. More recently, however, endoscopic identification of MD has been possible with the use of balloon-assisted enteroscopy via direct luminal access, which also provides visualization of the diverticular ostium. The aim of this study was to review the diagnosis by double-balloon enteroscopy of 4 adults with symptomatic MD but who had negative diagnostic imaging workups. These cases indicate that balloon-assisted enteroscopy is a valuable diagnostic method and should be considered in adult patients who have suspected MD and indefinite findings on diagnostic imaging workup, including negative Meckel’s scan. PMID:27803776

  15. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  16. Computer System For Diagnostics of Mobile Machinery Transmission

    Directory of Open Access Journals (Sweden)

    G. L. Antipenko

    2004-01-01

    Full Text Available A new method for diagnostics of mechanical transmissions of mobile machinery is proposed in the paper. The method presupposes an application of computing equipment and its purpose is to decrease labor-consumption of diagnostics procedure and increase diagnostics efficiency.The method is based on comparison of duration of impulse periods picked up at primary transducers which are installed at transmission input and output. A signal picked up at a flywheel ring gear is taken as a reference signal.While selecting clearances of one and then the direction in speed-up - braking transmission regime changes in number of reference impulses at output provide data on angular clearance value in every gearing. As data are supplied registration and processing of results and forecasting of residual resource are to be done with the help of a program on the basis of realized algorithms for every gearing.

  17. Computer-aided diagnosis workstation and teleradiology network system for chest diagnosis using the web medical image conference system with a new information security solution

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kaneko, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki

    2010-03-01

    Diagnostic MDCT imaging requires a considerable number of images to be read. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. Because of such a background, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis. We also have developed the teleradiology network system by using web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. Our teleradiology network system can perform Web medical image conference in the medical institutions of a remote place using the web medical image conference system. We completed the basic proof experiment of the web medical image conference system with information security solution. We can share the screen of web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with the workstation that builds in some diagnostic assistance methods. Biometric face authentication used on site of teleradiology makes "Encryption of file" and "Success in login" effective. Our Privacy and information security technology of information security solution ensures compliance with Japanese regulations. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new teleradiology network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis

  18. Computer assisted visualization of digital mammography images

    International Nuclear Information System (INIS)

    Funke, M.; Breiter, N.; Grabbe, E.; Netsch, T.; Biehl, M.; Peitgen, H.O.

    1999-01-01

    Purpose: In a clinical study, the feasibility of using a mammography workstation for the display and interpretation of digital mammography images was evaluated and the results were compared with the corresponding laser film hard copies. Materials and Methods: Digital phosphorous plate radiographs of the entire breast were obtained in 30 patients using a direct magnification mammography system. The images were displayed for interpretation on the computer monitor of a dedicated mammography workstation and also presented as laser film hard copies on a film view box for comparison. The images were evaluted with respect to the image handling, the image quality and the visualization of relevant structures by 3 readers. Results: Handling and contrast of the monitor displayed images were found to be superior compared with the film hard copies. Image noise was found in some cases but did not compromise the interpretation of the monitor images. The visualization of relevant structures was equal with both modalities. Altogether, image interpretation with the mammography workstation was considered to be easy, quick and confident. Conclusions: Computer-assisted visualization and interpretation of digital mammography images using a dedicated workstation can be performed with sufficiently high diagnostic accuracy. (orig.) [de

  19. Prodiag--a hybrid artificial intelligence based reactor diagnostic system for process faults

    International Nuclear Information System (INIS)

    Reifman, J.; Wei, T.Y.C.; Vitela, J.E.; Applequist, C. A.; Chasensky, T.M.

    1996-01-01

    Commonwealth Research Corporation (CRC) and Argonne National Laboratory (ANL) are collaborating on a DOE-sponsored Cooperative Research and Development Agreement (CRADA), project to perform feasibility studies on a novel approach to Artificial Intelligence (Al) based diagnostics for component faults in nuclear power plants. Investigations are being performed in the construction of a first-principles physics-based plant level process diagnostic expert system (ES) and the identification of component-level fault patterns through operating component characteristics using artificial neural networks (ANNs). The purpose of the proof-of-concept project is to develop a computer-based system using this Al approach to assist process plant operators during off-normal plant conditions. The proposed computer-based system will use thermal hydraulic (T-H) signals complemented by other non-T-H signals available in the data stream to provide the process operator with the component which most likely caused the observed process disturbance.To demonstrate the scale-up feasibility of the proposed diagnostic system it is being developed for use with the Chemical Volume Control System (CVCS) of a nuclear power plant. A full-scope operator training simulator representing the Commonwealth Edison Braidwood nuclear power plant is being used both as the source of development data and as the means to evaluate the advantages of the proposed diagnostic system. This is an ongoing multi-year project and this paper presents the results to date of the CRADA phase

  20. 21 CFR 870.1425 - Programmable diagnostic computer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Programmable diagnostic computer. 870.1425 Section 870.1425 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...

  1. Emotion-Aware Assistive System for Humanistic Care Based on the Orange Computing Concept

    Directory of Open Access Journals (Sweden)

    Jhing-Fa Wang

    2012-01-01

    Full Text Available Mental care has become crucial with the rapid growth of economy and technology. However, recent movements, such as green technologies, place more emphasis on environmental issues than on mental care. Therefore, this study presents an emerging technology called orange computing for mental care applications. Orange computing refers to health, happiness, and physiopsychological care computing, which focuses on designing algorithms and systems for enhancing body and mind balance. The representative color of orange computing originates from a harmonic fusion of passion, love, happiness, and warmth. A case study on a human-machine interactive and assistive system for emotion care was conducted in this study to demonstrate the concept of orange computing. The system can detect emotional states of users by analyzing their facial expressions, emotional speech, and laughter in a ubiquitous environment. In addition, the system can provide corresponding feedback to users according to the results. Experimental results show that the system can achieve an accurate audiovisual recognition rate of 81.8% on average, thereby demonstrating the feasibility of the system. Compared with traditional questionnaire-based approaches, the proposed system can offer real-time analysis of emotional status more efficiently.

  2. Evaluating and tuning system response in the MFTF-B control and diagnostics computers

    International Nuclear Information System (INIS)

    Palasek, R.L.; Butner, D.N.; Minor, E.G.

    1983-01-01

    The software system running on the Supervisory Control and Diagnostics System (SCDS) of MFTF-B is, for the major part, an event driven one. Regular, periodic polling of sensors' outputs takes place only at the local level, in the sensors' corresponding local control microcomputers (LCC's). An LCC reports a sensor's value to the supervisory computer only if there was a significant change. This report is passed as a message, routed among and acted upon by a network of applications and systems tasks within the supervisory computer (SCDS). Commands from the operator's console are similarly routed through a network of tasks, but in the oppostie direction to the experiment's hardware. In a network such as this, response time is partialy determined by system traffic. Because the hardware of MFTF-B will not be connected to the computer system for another two years, we are using the local control computers to simulate the event driven traffic that we expect to see during MFTF-B operation. In this paper we show how we are using the simulator to measure and evaluate response, loading, throughput, and utilization of components within the computer system. Measurement of the system under simulation allows us to identify bottlenecks and verify their unloosening. We also use the traffic simulators to evaluate prototypes of different algorithms for selected tasks, comparing their responses under the spectrum of traffic intensities

  3. Computer-assisted instruction

    NARCIS (Netherlands)

    Voogt, J.; Fisser, P.; Wright, J.D.

    2015-01-01

    Since the early days of computer technology in education in the 1960s, it was claimed that computers can assist instructional practice and hence improve student learning. Since then computer technology has developed, and its potential for education has increased. In this article, we first discuss

  4. Utilizing Computer Integration to Assist Nursing

    OpenAIRE

    Hujcs, Marianne

    1990-01-01

    As the use of computers in health care continues to increase, methods of using these computers to assist nursing practice are also increasing. This paper describes how integration within a hospital information system (HIS) contributed to the development of a report format and computer generated alerts used by nurses. Discussion also includes how the report and alerts impact those nurses providing bedside care as well as how integration of an HIS creates challenges for nursing.

  5. Computerized Diagnostic Assistant for the Automatic Detection of Pneumothorax on Ultrasound: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Shane M. Summers, MD, RDMS

    2016-03-01

    Full Text Available Introduction: Bedside thoracic ultrasound (US can rapidly diagnose pneumothorax (PTX with improved accuracy over the physical examination and without the need for chest radiography (CXR; however, US is highly operator dependent. A computerized diagnostic assistant was developed by the United States Army Institute of Surgical Research to detect PTX on standard thoracic US images. This computer algorithm is designed to automatically detect sonographic signs of PTX by systematically analyzing B-mode US video clips for pleural sliding and M-mode still images for the seashore sign. This was a pilot study to estimate the diagnostic accuracy of the PTX detection computer algorithm when compared to an expert panel of US trained physicians. Methods: This was a retrospective study using archived thoracic US obtained on adult patients presenting to the emergency department (ED between 5/23/2011 and 8/6/2014. Emergency medicine residents, fellows, attending physicians, physician assistants, and medical students performed the US examinations and stored the images in the picture archive and communications system (PACS. The PACS was queried for all ED bedside US examinations with reported positive PTX during the study period along with a random sample of negatives. The computer algorithm then interpreted the images, and we compared the results to an independent, blinded expert panel of three physicians, each with experience reviewing over 10,000 US examinations. Results: Query of the PACS system revealed 146 bedside thoracic US examinations for analysis. Thirteen examinations were indeterminate and were excluded. There were 79 true negatives, 33 true positives, 9 false negatives, and 12 false positives. The test characteristics of the algorithm when compared to the expert panel were sensitivity 79% (95 % CI [63-89] and specificity 87% (95% CI [77-93]. For the 20 images scored as highest quality by the expert panel, the algorithm demonstrated 100% sensitivity

  6. To EDF: PHOEBUS, computer-assisted engineering

    International Nuclear Information System (INIS)

    Lecocq, P.; Goudal, J.C.; Barache, J.M.; Feingold, D.; Cornon, P.

    1986-01-01

    EDF has built a modular integrated computer-assisted nuclear engineering (CAE) system called POEBUS. Since 1975, the Organization has been interested in CAE which places computer methods and technology at the disposal of the engineering department. This paper describes the changes and their effect on the techniques in use, working methods and the personnel called on to put them into operation [fr

  7. Computer Assistance for Writing Interactive Programs: TICS.

    Science.gov (United States)

    Kaplow, Roy; And Others

    1973-01-01

    Investigators developed an on-line, interactive programing system--the Teacher-Interactive Computer System (TICS)--to provide assistance to those who were not programers, but nevertheless wished to write interactive instructional programs. TICS had two components: an author system and a delivery system. Underlying assumptions were that…

  8. Computer-aided diagnosis workstation and data base system for chest diagnosis based on multihelical CT images

    International Nuclear Information System (INIS)

    Satoh, H.; Niki, N.; Eguchi, K.; Masuda, H.; Machida, S.; Moriyama, N.

    2006-01-01

    We have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router, Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information. (author)

  9. Embedded Platforms for Computer Vision-based Advanced Driver Assistance Systems: a Survey

    OpenAIRE

    Velez, Gorka; Otaegui, Oihana

    2015-01-01

    Computer Vision, either alone or combined with other technologies such as radar or Lidar, is one of the key technologies used in Advanced Driver Assistance Systems (ADAS). Its role understanding and analysing the driving scene is of great importance as it can be noted by the number of ADAS applications that use this technology. However, porting a vision algorithm to an embedded automotive system is still very challenging, as there must be a trade-off between several design requisites. Further...

  10. An investigation into the use of ''expert systems'' for system-wide diagnostics

    International Nuclear Information System (INIS)

    Booth, A.W.; Carroll, J.T.

    1987-01-01

    This paper has explained how expert systems function and how they might be used to provide a FASTBUS system-wide diagnostic program. The authors propose that the system be used to diagnose the FASTBUS system at FERMILAB's CDF experiment. There are many important areas which have not been addressed in great detail in this paper (such as the roles of the knowledge engineer and the expert during the knowledge acquisition phase), but the central idea of the embodiment of an expert skill in a computer is clear. Development of a system-wide diagnostic program requires building knowledge from all our system experts, into the system. To expand the expert system beyond its network diagnostic ability, to include finding faulty modules would be worthwhile. Having an ''intelligent'' assistant who is on shift 24 hours each day would relieve the ''real'' experts from laborious, time-consuming and sometimes repetitive tasks undertaken during the debugging process. The system could also provide a testbed for evaluation and comparison when considering future expert-system applications such as ''run-control'' and ''data analysis''. In the context of a system-wide diagnostic program, an ''expert system'' is not intended to replace human experts but simply to help them. It is envisaged that there will always be important interaction between the human expert and the ''expert system''. The incremental development of the ''expert system'' should ensure that it is useful in the short term (by debugging to the S.I./segment level for example), and even more useful in the medium to longer term as it acquires more and more knowledge and the ability to debug to the module level. Expert systems exist and are working successfully in many problem domains. See the bibliography for examples of ''expert systems'' built in the high energy physics environment

  11. A computer-assisted proof for the existence of horseshoe in a novel chaotic system

    International Nuclear Information System (INIS)

    Wu Wenjuan; Chen Zengqiang; Yuan Zhuzhi

    2009-01-01

    The dynamics of a novel chaotic system are studied, and a rigorous computer-assisted proof for existence of horseshoe in this system is given. A Poincare section is properly chosen to obtain the Poincare map, which is proved to be semi-conjugate to the 4-shift map by utilizing topological horseshoe theory. This implies the entropy of the system is no less than log 4, and the system definitely exhibits chaos.

  12. Computer-Assisted Instruction: Authoring Languages. ERIC Digest.

    Science.gov (United States)

    Reeves, Thomas C.

    One of the most perplexing tasks in producing computer-assisted instruction (CAI) is the authoring process. Authoring is generally defined as the process of turning the flowcharts, control algorithms, format sheets, and other documentation of a CAI program's design into computer code that will operationalize the simulation on the delivery system.…

  13. NPP Mochovce units 1 and 2 diagnostic systems

    International Nuclear Information System (INIS)

    Heidenreich, S.

    1997-01-01

    In this paper the diagnostic systems (leak detection monitoring, vibration monitoring, lose parts monitoring, fatigue monitoring) of NPP Mochovce units 1 and 2 are presented. All of the designed diagnostic systems are personal computer based systems

  14. Intelligent Decisional Assistant that Facilitate the Choice of a Proper Computer System Applied in Busines

    OpenAIRE

    Nicolae MARGINEAN

    2009-01-01

    The choice of a proper computer system is not an easy task for a decider. One reason could be the present market development of computer systems applied in business. The big number of the Romanian market players determines a big number of computerized products, with a multitude of various properties. Our proposal tries to optimize and facilitate this decisional process within an e-shop where are sold IT packets applied in business, building an online decisional assistant, a special component ...

  15. Cooperative research and development for artificial intelligence based reactor diagnostic system

    International Nuclear Information System (INIS)

    Reifman, J.; Wei, T.Y.C.; Abboud, R.G.; Chasensky, T.M.

    1994-01-01

    Artificial Intelligence (AI) techniques in the form of knowledge-based Expert Systems (ESs) have been proposed to provide on-line decision-making support for plant operators during both normal and emergency conditions. However, in spite of the great interest in these advanced techniques, their application in the diagnosis of large-scale processes has not yet reached its full potential because of limitations of the knowledge base. These limitations include problems with knowledge acquisition and the use of an event-oriented approach for process diagnosis. To investigate the capabilities of this two-level hierarchical knowledge structure, Commonwealth Research Corporation (CRC) and Argonne National Laboratory (ANL)are collaborating on a DOE-sponsored Cooperative Research and Development Agreement (CRADA) project to perform feasibility studies on the proposed diagnostic system. Investigations are being performed in the construction of a physics-based plant level process diagnostic ES and the characterization of component-level fault project is to develop a computer-based system using this Al approach to assist process plant operators during off-normal plant conditions. The proposed computer-based system will use T-H signals complemented by other non-T-H signals available in the data stream to provide the process operator with the component which most likely caused the observed process disturbance. To demonstrate the scale-up feasibility of the proposed diagnostic system it is being developed for use with the Chemical Volume Control System (CVCS) of a nuclear power plant. This is an ongoing multi-year project and the remainder of this paper presents a mid-term status report

  16. Environmental Factors Affecting Computer Assisted Language Learning Success: A Complex Dynamic Systems Conceptual Model

    Science.gov (United States)

    Marek, Michael W.; Wu, Wen-Chi Vivian

    2014-01-01

    This conceptual, interdisciplinary inquiry explores Complex Dynamic Systems as the concept relates to the internal and external environmental factors affecting computer assisted language learning (CALL). Based on the results obtained by de Rosnay ["World Futures: The Journal of General Evolution", 67(4/5), 304-315 (2011)], who observed…

  17. Implementing a computer-assisted telephone interview (CATI) system to increase colorectal cancer screening: a process evaluation.

    Science.gov (United States)

    White, Mary Jo; Stark, Jennifer R; Luckmann, Roger; Rosal, Milagros C; Clemow, Lynn; Costanza, Mary E

    2006-06-01

    Computer-assisted telephone interviewing (CATI) systems used by telephone counselors (TCs) may be efficient mechanisms to counsel patients on cancer and recommended preventive screening tests in order to extend a primary care provider's reach to his/her patients. The implementation process of such a system for promoting colorectal (CRC) cancer screening using a computer-assisted telephone interview (CATI) system is reported in this paper. The process evaluation assessed three components of the intervention: message production, program implementation and audience reception. Of 1181 potentially eligible patients, 1025 (87%) patients were reached by the TCs and 725 of those patients (71%) were eligible to receive counseling. Five hundred eighty-two (80%) patients agreed to counseling. It is feasible to design and use CATI systems for prevention counseling of patients in primary care practices. CATI systems have the potential of being used as a referral service by primary care providers and health care organizations for patient education.

  18. Computer-Assisted Diagnosis of the Sleep Apnea-Hypopnea Syndrome: A Review

    Science.gov (United States)

    Alvarez-Estevez, Diego; Moret-Bonillo, Vicente

    2015-01-01

    Automatic diagnosis of the Sleep Apnea-Hypopnea Syndrome (SAHS) has become an important area of research due to the growing interest in the field of sleep medicine and the costs associated with its manual diagnosis. The increment and heterogeneity of the different techniques, however, make it somewhat difficult to adequately follow the recent developments. A literature review within the area of computer-assisted diagnosis of SAHS has been performed comprising the last 15 years of research in the field. Screening approaches, methods for the detection and classification of respiratory events, comprehensive diagnostic systems, and an outline of current commercial approaches are reviewed. An overview of the different methods is presented together with validation analysis and critical discussion of the current state of the art. PMID:26266052

  19. Blackboard architecture and qualitative model in a computer aided assistant designed to define computers for HEP computing

    International Nuclear Information System (INIS)

    Nodarse, F.F.; Ivanov, V.G.

    1991-01-01

    Using BLACKBOARD architecture and qualitative model, an expert systm was developed to assist the use in defining the computers method for High Energy Physics computing. The COMEX system requires an IBM AT personal computer or compatible with than 640 Kb RAM and hard disk. 5 refs.; 9 figs

  20. Beam diagnostic system for SSC on HIRFL central console

    International Nuclear Information System (INIS)

    Zhang Guixu; Wang Zhen; Huang Tuanhua

    1998-01-01

    The SSC ion beam diagnostic system on the console of HIRFL in institute of modern physics is presented. The information between console and diagnostic system can be transferred via DECnet communication. The central computer for HIRFL console is VAX-8350, the working computer of diagnostic system is changed from IBM PC/XT to COMPAQ 486, and the operating program is rewritten from FORTRAN to C. In order to communicate information, DECnet TTT function is put into both programs on the VAX and PC

  1. Non-invasive brain-computer interface system: towards its application as assistive technology.

    Science.gov (United States)

    Cincotti, Febo; Mattia, Donatella; Aloise, Fabio; Bufalari, Simona; Schalk, Gerwin; Oriolo, Giuseppe; Cherubini, Andrea; Marciani, Maria Grazia; Babiloni, Fabio

    2008-04-15

    The quality of life of people suffering from severe motor disabilities can benefit from the use of current assistive technology capable of ameliorating communication, house-environment management and mobility, according to the user's residual motor abilities. Brain-computer interfaces (BCIs) are systems that can translate brain activity into signals that control external devices. Thus they can represent the only technology for severely paralyzed patients to increase or maintain their communication and control options. Here we report on a pilot study in which a system was implemented and validated to allow disabled persons to improve or recover their mobility (directly or by emulation) and communication within the surrounding environment. The system is based on a software controller that offers to the user a communication interface that is matched with the individual's residual motor abilities. Patients (n=14) with severe motor disabilities due to progressive neurodegenerative disorders were trained to use the system prototype under a rehabilitation program carried out in a house-like furnished space. All users utilized regular assistive control options (e.g., microswitches or head trackers). In addition, four subjects learned to operate the system by means of a non-invasive EEG-based BCI. This system was controlled by the subjects' voluntary modulations of EEG sensorimotor rhythms recorded on the scalp; this skill was learnt even though the subjects have not had control over their limbs for a long time. We conclude that such a prototype system, which integrates several different assistive technologies including a BCI system, can potentially facilitate the translation from pre-clinical demonstrations to a clinical useful BCI.

  2. 21 CFR 870.1435 - Single-function, preprogrammed diagnostic computer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Single-function, preprogrammed diagnostic computer... Single-function, preprogrammed diagnostic computer. (a) Identification. A single-function, preprogrammed diagnostic computer is a hard-wired computer that calculates a specific physiological or blood-flow parameter...

  3. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-06-15

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery.

  4. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    International Nuclear Information System (INIS)

    2008-01-01

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery

  5. A guide for the selection of computer assisted mapping (CAM) and facilities informations systems

    Energy Technology Data Exchange (ETDEWEB)

    Haslin, S.; Baxter, P.; Jarvis, L.

    1980-12-01

    Many distribution engineers are now aware that computer assisted mapping (CAM) and facilities informations systems are probably the most significant breakthrough to date in computer applications for distribution engineering. The Canadian Electrical Asociation (CEA) recognized this and requested engineers of B.C. Hydro make a study of the state of the art in Canadian utilities and the progress of CAM systems on an international basis. The purpose was to provide a guide to assist Canadian utility distribution engineers faced with the problem of studying the application of CAM systems as an alternative to present methods, consideration being given to the long-term and other benefits that were perhaps not apparent for those approaching this field for the first time. It soon became apparent that technology was developing at a high rate and competition in the market was very strong. Also a number of publications were produced by other sources which adequately covered the scope of this study. This report is thus a collection of references to reports, manuals, and other documents with a few considerations provided for those companies interested in exploring further the use of interactive graphics. 24 refs.

  6. 76 FR 15321 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition...

    Science.gov (United States)

    2011-03-21

    ...] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition for Review... an advisory committee Ethicon Endo- Surgery Inc.'s (EES's), petition for review of the Agency's... Foreman, FDA, CDRH, to Ken Charak, Ethicon Endo-Surgery, Inc., containing the order denying approval of...

  7. Computer Assisted Language Learning. Routledge Studies in Computer Assisted Language Learning

    Science.gov (United States)

    Pennington, Martha

    2011-01-01

    Computer-assisted language learning (CALL) is an approach to language teaching and learning in which computer technology is used as an aid to the presentation, reinforcement and assessment of material to be learned, usually including a substantial interactive element. This books provides an up-to date and comprehensive overview of…

  8. Computer-assisted system for diagnosing degenerative dementia using cerebral blood flow SPECT and 3D-SSP. A multicenter study

    International Nuclear Information System (INIS)

    Ishii, Kazunari; Ito, Kengo; Nakanishi, Atsushi; Kitamura, Shin; Terashima, Akira

    2014-01-01

    Due to increasing numbers of patients with dementia, more physicians who do not specialize in brain nuclear medicine are being asked to interpret SPECT images of cerebral blood flow. We conducted a multicenter study to determine whether a computer-assisted diagnostic system Z-score summation analysis method (ZSAM) using three-dimensional stereotactic surface projections (3D-SSP) can differentiate Alzheimer's disease (AD)/dementia with Lewy bodies (DLB) and non-AD/DLB in institutions using various types of gamma cameras. We determined the normal thresholds of Z-sum (summed Z-score) within a template region of interest for each single photon emission computed tomography (SPECT) device and then compared them with the Z-sums of patients and calculated the accuracy of the differential diagnosis by ZSAM. We compared the diagnostic accuracy between ZSAM and visual assessment. We enrolled 202 patients with AD (mean age, 76.8 years), 40 with DLB (mean age 76.3 years) and 36 with non-AD/DLB (progressive supranuclear palsy, n=10; frontotemporal dementia, n=20; slowly progressive aphasia, n=2 and one each with idiopathic normal pressure hydrocephalus, corticobasal degeneration, multiple system atrophy and Parkinson's disease) who underwent N-isopropyl-p-[ 123 I] iodoamphetamine cerebral blood flow SPECT imaging at each participating institution. The ZSAM sensitivity to differentiate between AD/DLB and non-AD/DLB in all patients, as well as those with mini-mental state examination scores of ≥24 and 20-23 points were 88.0, 78.0 and 88.4%, respectively, with specificity of 50.0, 44.4 and 60.0%, respectively. The diagnostic accuracy rates were 83.1, 72.9 and 84.2%, respectively. The areas under receiver operating characteristics curves for visual inspection by four expert raters were 0.74-0.84, 0.66-0.85 and 0.81-0.93, respectively, in the same patient groups. The diagnostic accuracy rates were 70.9-89.2%, 50.9-84.8% and 76.2-93.1%, respectively. The diagnostic

  9. Computer aided detection system for lung cancer using computer tomography scans

    Science.gov (United States)

    Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.

    2018-04-01

    Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.

  10. ATA diagnostic data handling system: an overview

    International Nuclear Information System (INIS)

    Chambers, F.W.; Kallman, J.; McDonald, J.; Slominski, M.

    1984-01-01

    The functions to be performed by the ATA diagnostic data handling system are discussed. The capabilities of the present data acquisition system (System 0) are presented. The goals for the next generation acquisition system (System 1), currently under design, are discussed. Facilities on the Octopus system for data handling are reviewed. Finally, we discuss what has been learned about diagnostics and computer based data handling during the past year

  11. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and

  12. Non invasive Brain-Computer Interface system: towards its application as assistive technology

    Science.gov (United States)

    Cincotti, Febo; Mattia, Donatella; Aloise, Fabio; Bufalari, Simona; Schalk, Gerwin; Oriolo, Giuseppe; Cherubini, Andrea; Marciani, Maria Grazia; Babiloni, Fabio

    2010-01-01

    The quality of life of people suffering from severe motor disabilities can benefit from the use of current assistive technology capable of ameliorating communication, house-environment management and mobility, according to the user's residual motor abilities. Brain Computer Interfaces (BCIs) are systems that can translate brain activity into signals that control external devices. Thus they can represent the only technology for severely paralyzed patients to increase or maintain their communication and control options. Here we report on a pilot study in which a system was implemented and validated to allow disabled persons to improve or recover their mobility (directly or by emulation) and communication within the surrounding environment. The system is based on a software controller that offers to the user a communication interface that is matched with the individual's residual motor abilities. Patients (n=14) with severe motor disabilities due to progressive neurodegenerative disorders were trained to use the system prototype under a rehabilitation program carried out in a house-like furnished space. All users utilized regular assistive control options (e.g., microswitches or head trackers). In addition, four subjects learned to operate the system by means of a non-invasive EEG-based BCI. This system was controlled by the subjects' voluntary modulations of EEG sensorimotor rhythms recorded on the scalp; this skill was learnt even though the subjects have not had control over their limbs for a long time. We conclude that such a prototype system, which integrates several different assistive technologies including a BCI system, can potentially facilitate the translation from pre-clinical demonstrations to a clinical useful BCI. PMID:18394526

  13. Reliability and diagnostic of modular systems

    Directory of Open Access Journals (Sweden)

    J. Kohlas

    2014-01-01

    Full Text Available Reliability and diagnostic are in general two problems discussed separately. Yet the two problems are in fact closely related to each other. Here, this relation is considered in the simple case of modular systems. We show, how the computation of reliability and diagnostic can efficiently be done within the same Bayesian network induced by the modularity of the structure function of the system.

  14. Computer-assisted estimating for the Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Spooner, J.E.

    1976-02-01

    An analysis is made of the cost estimating system currently in use at the Los Alamos Scientific Laboratory (LASL) and the benefits of computer assistance are evaluated. A computer-assisted estimating system (CAE) is proposed for LASL. CAE can decrease turnaround and provide more flexible response to management requests for cost information and analyses. It can enhance value optimization at the design stage, improve cost control and change-order justification, and widen the use of cost information in the design process. CAE costs are not well defined at this time although they appear to break even with present operations. It is recommended that a CAE system description be submitted for contractor consideration and bid while LASL system development continues concurrently

  15. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    Science.gov (United States)

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  16. Computer-Assisted Periodical Routing and Renewal Audit

    Science.gov (United States)

    Yerkey, A. Neil

    1973-01-01

    A computer-assisted periodical control system was designed to reduce clerical time required to maintain records in three areas: renewal audit, routing, and records-keeping. The renewal audit features are unusual and are described in detail. (3 references) (Author/DH)

  17. Medical image computing and computer-assisted intervention - MICCAI 2005. Proceedings; Pt. 1

    International Nuclear Information System (INIS)

    Duncan, J.S.; Gerig, G.

    2005-01-01

    The two-volume set LNCS 3749 and LNCS 3750 constitutes the refereed proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2005, held in Palm Springs, CA, USA, in October 2005. Based on rigorous peer reviews the program committee selected 237 carefully revised full papers from 632 submissions for presentation in two volumes. The first volume includes all the contributions related to image analysis and validation, vascular image segmentation, image registration, diffusion tensor image analysis, image segmentation and analysis, clinical applications - validation, imaging systems - visualization, computer assisted diagnosis, cellular and molecular image analysis, physically-based modeling, robotics and intervention, medical image computing for clinical applications, and biological imaging - simulation and modeling. The second volume collects the papers related to robotics, image-guided surgery and interventions, image registration, medical image computing, structural and functional brain analysis, model-based image analysis, image-guided intervention: simulation, modeling and display, and image segmentation and analysis. (orig.)

  18. Medical image computing and computer-assisted intervention - MICCAI 2005. Proceedings; Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.S. [Yale Univ., New Haven, CT (United States). Dept. of Biomedical Engineering and Diagnostic Radiology; Gerig, G. (eds.) [North Carolina Univ., Chapel Hill (United States). Dept. of Computer Science

    2005-07-01

    The two-volume set LNCS 3749 and LNCS 3750 constitutes the refereed proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2005, held in Palm Springs, CA, USA, in October 2005. Based on rigorous peer reviews the program committee selected 237 carefully revised full papers from 632 submissions for presentation in two volumes. The first volume includes all the contributions related to image analysis and validation, vascular image segmentation, image registration, diffusion tensor image analysis, image segmentation and analysis, clinical applications - validation, imaging systems - visualization, computer assisted diagnosis, cellular and molecular image analysis, physically-based modeling, robotics and intervention, medical image computing for clinical applications, and biological imaging - simulation and modeling. The second volume collects the papers related to robotics, image-guided surgery and interventions, image registration, medical image computing, structural and functional brain analysis, model-based image analysis, image-guided intervention: simulation, modeling and display, and image segmentation and analysis. (orig.)

  19. [Computed tomography with computer-assisted detection of pulmonary nodules in dogs and cats].

    Science.gov (United States)

    Niesterok, C; Piesnack, S; Köhler, C; Ludewig, E; Alef, M; Kiefer, I

    2015-01-01

    The aim of this study was to assess the potential benefit of computer-assisted detection (CAD) of pulmonary nodules in veterinary medicine. Therefore, the CAD rate was compared to the detection rates of two individual examiners in terms of its sensitivity and false-positive findings. We included 51 dogs and 16 cats with pulmonary nodules previously diagnosed by computed tomography. First, the number of nodules ≥ 3 mm was recorded for each patient by two independent examiners. Subsequently, each examiner used the CAD software for automated nodule detection. With the knowledge of the CAD results, a final consensus decision on the number of nodules was achieved. The software used was a commercially available CAD program. The sensitivity of examiner 1 was 89.2%, while that of examiner 2 reached 87.4%. CAD had a sensitivity of 69.4%. With CAD, the sensitivity of examiner 1 increased to 94.7% and that of examiner 2 to 90.8%. The CAD-system, which we used in our study, had a moderate sensitivity of 69.4%. Despite its severe limitations, with a high level of false-positive and false-negative results, CAD increased the examiners' sensitivity. Therefore, its supportive role in diagnostics appears to be evident.

  20. Photolithography diagnostic expert systems: a systematic approach to problem solving in a wafer fabrication facility

    Science.gov (United States)

    Weatherwax Scott, Caroline; Tsareff, Christopher R.

    1990-06-01

    One of the main goals of process engineering in the semiconductor industry is to improve wafer fabrication productivity and throughput. Engineers must work continuously toward this goal in addition to performing sustaining and development tasks. To accomplish these objectives, managers must make efficient use of engineering resources. One of the tools being used to improve efficiency is the diagnostic expert system. Expert systems are knowledge based computer programs designed to lead the user through the analysis and solution of a problem. Several photolithography diagnostic expert systems have been implemented at the Hughes Technology Center to provide a systematic approach to process problem solving. This systematic approach was achieved by documenting cause and effect analyses for a wide variety of processing problems. This knowledge was organized in the form of IF-THEN rules, a common structure for knowledge representation in expert system technology. These rules form the knowledge base of the expert system which is stored in the computer. The systems also include the problem solving methodology used by the expert when addressing a problem in his area of expertise. Operators now use the expert systems to solve many process problems without engineering assistance. The systems also facilitate the collection of appropriate data to assist engineering in solving unanticipated problems. Currently, several expert systems have been implemented to cover all aspects of the photolithography process. The systems, which have been in use for over a year, include wafer surface preparation (HMDS), photoresist coat and softbake, align and expose on a wafer stepper, and develop inspection. These systems are part of a plan to implement an expert system diagnostic environment throughout the wafer fabrication facility. In this paper, the systems' construction is described, including knowledge acquisition, rule construction, knowledge refinement, testing, and evaluation. The roles

  1. A Computer-Based, Interactive Videodisc Job Aid and Expert System for Electron Beam Lithography Integration and Diagnostic Procedures.

    Science.gov (United States)

    Stevenson, Kimberly

    This master's thesis describes the development of an expert system and interactive videodisc computer-based instructional job aid used for assisting in the integration of electron beam lithography devices. Comparable to all comprehensive training, expert system and job aid development require a criterion-referenced systems approach treatment to…

  2. Modeling and diagnostic techniques applicable to the analysis of pressure noise in pressurized water reactors and pressure-sensing systems

    International Nuclear Information System (INIS)

    Mullens, J.A.; Thie, J.A.

    1984-01-01

    Pressure noise data from a PWR are interpreted by means of a computer-implemented model. The model's parameters, namely hydraulic impedances and noise sources, are either calculated or deduced from fits to data. Its accuracy is encouraging and raises the possibility of diagnostic assistance for nuclear plant monitoring. A number of specific applications of pressure noise in the primary system of a PWR and in a pressure sensing system are suggested

  3. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended to...

  4. Electron beam diagnostic system using computed tomography and an annular sensor

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.

    2014-07-29

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  5. Generative Computer Assisted Instruction: An Application of Artificial Intelligence to CAI.

    Science.gov (United States)

    Koffman, Elliot B.

    Frame-oriented computer-assisted instruction (CAI) systems dominate the field, but these mechanized programed texts utilize the computational power of the computer to a minimal degree and are difficult to modify. Newer, generative CAI systems which are supplied with a knowledge of subject matter can generate their own problems and solutions, can…

  6. Computer-assisted oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Hassfeld, S.; Brief, J.; Muehling, J.; Krempien, R.; Mende, U.; Raczkowsky, J.; Muenchenberg, J.; Woern, H.; Giess, H.; Meinzer, H.P.

    2000-01-01

    Background: Methods from the area of virtual reality are used in oral and maxillofacial surgery for the planning and three-dimensional individual simulation of surgeries. Simulation: In order to simulate complex surgeries with the aid of a computer, the diagnostic image data and especially various imaging modalities (CT, MRT, US) must be arranged in relation to each other, thus enabling rapid switching between the various modalities as well as the viewing of mixed images. Segmenting techniques for the reconstruction of three-dimensional representations of soft-tissue and osseous areas are required. We must develop ergonomic and intuitively useable interaction methods for the surgeon, thus allowing for precise and fast entry of the planned surgical intervention in the planning and simulation phase. Surgery: During the surgical phase, instrument navigation tools offer the surgeon interactive support through operation guidance and control of potential dangers. This feature is already available today. Future intraoperative assistance will take the form of such passive tools for the support of intraoperative orientation as well as so-called tracking systems (semi-active systems) which accompany and support the surgeons' work. The final form are robots which execute specific steps completely autonomously. Discussion: The techniques of virtual reality keep gaining in importance for medical applications. Many applications are still being developed or are still in the form of a prototype. However, it is already clear that developments in this area will have a considerable effect on the surgeon's routine work. (orig.) [de

  7. Computer Assisted Instruction

    Science.gov (United States)

    Higgins, Paul

    1976-01-01

    Methodology for developing a computer assisted instruction (CAI) lesson (scripting, programing, and testing) is reviewed. A project done by Informatics Education Ltd. (IEL) for the Department of National Defense (DND) is used as an example. (JT)

  8. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  9. Supervisory control and diagnostics system for the mirror fusion test facility: overview and status 1980

    International Nuclear Information System (INIS)

    McGoldrick, P.R.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is a complex facility requiring a highly-computerized Supervisory Control and Diagnostics System (SCDS) to monitor and provide control over ten subsystems; three of which require true process control. SCDS will provide physicists with a method of studying machine and plasma behavior by acquiring and processing up to four megabytes of plasma diagnostic information every five minutes. A high degree of availability and throughput is provided by a distributed computer system (nine 32-bit minicomputers on shared memory). Data, distributed across SCDS, is managed by a high-bandwidth Distributed Database Management System. The MFTF operators' control room consoles use color television monitors with touch sensitive screens; this is a totally new approach. The method of handling deviations to normal machine operation and how the operator should be notified and assisted in the resolution of problems has been studied and a system designed

  10. A management system of data for department of diagnostic radiology and patients using the personal computer

    International Nuclear Information System (INIS)

    Kim, Jin Hee; Park, Tae Joon; Choi, Tae Haing; Lim, Se Hwan; Joon Yang Noh; Kim, Sung Jin

    1996-01-01

    With the use of personal computers generalized, departmental society leveled computerization is going on in some other departments. So we tried to develop a program having a simple user interface, various retrieval functions and, analytic and statistic process system to effectively help patient care suitable for works concerned with department of diagnostic radiology and works of department. This program deals with such target works as department of diagnostic radiology and some works to need a lot of bookkeeping. It is deviced to operate with Windows (Microsoft, America), and central processing unit(486DX-2), memory unit(8 Mbyte). As a developmental tool, Foxpro 2.6 for windows R (Microsoft, America). This program can be easily accessed even by staffs poor at computer and it can make many books recording various check-ups and operations unnecessary, which were difficult to keep. Besides, it can keep data as a unified form, and so it provides patient care and other works with convenience and helps applying those stored data scientific research. The above result shows that works of department can be effectively controlled by analyzing or printing various check-up and operation done by department of diagnostic radiology

  11. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  12. A Look at Computer-Assisted Testing Operations. The Illinois Series on Educational Application of Computers, No. 12e.

    Science.gov (United States)

    Muiznieks, Viktors; Dennis, J. Richard

    In computer assisted test construction (CATC) systems, the computer is used to perform the mechanical aspects of testing while the teacher retains control over question content. Advantages of CATC systems include question banks, decreased importance of test item security, computer analysis and response to student test answers, item analysis…

  13. Computer-assisted indexing for the INIS database

    International Nuclear Information System (INIS)

    Nevyjel, A.

    2006-01-01

    INIS has identified computer-assisted indexing as areas where information technology could assist best in maintaining database quality and indexing consistency, while containing production costs. Subject analysis is a very important but also very expensive process in the production of the INIS database. Given the current necessity to process an increased number of records, including subject analysis, without additional staff, INIS as well as the member states need improvements in their processing efficiency. Computer assisted subject analysis is a promising way to achieve this. The quality of the INIS database is defined by its inputting rules. The Thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language. It is a controlled and dynamic vocabulary of semantically and generically related terms. It is the essential tool for subject analysis as well as for advanced search engines. To support the identification of descriptors in the free text (title, abstract, free keywords) 'hidden terms' have been introduced as extension of the Thesaurus, which identify phrases or character strings of free text and point to the valid descriptor, which should be suggested. In the process of computer-assisted subject analysis the bibliographic records (including title and abstract) are analyzed by the software, resulting in a list of suggested descriptors. Within the working platform (graphical user interface) the suggested descriptors are sorted by importance (by their relevance for the content of the document) and the subject specialist clearly sees the highlighted context from which the terms were selected. The system allows the subject specialist to accept or reject descriptors from the suggested list and to assign additional descriptors when necessary. First experiences show that a performance enhancement of about 80-100% can be achieved in the subject analysis process. (author)

  14. Designing an Assistant System Encouraging Ergonomic Computer Usage

    Directory of Open Access Journals (Sweden)

    Hüseyin GÜRÜLER

    2017-12-01

    Full Text Available Today, people of almost every age group are users of computers and computer aided systems. Technology makes our life easier, but it can also threaten our health. In recent years, one of the main causes of the proliferation of diseases such as lower back pain, neck pain or hernia, Arthritis, visual disturbances and obesity is wrong computer usage. The widespread use of computers also increases these findings. The purpose of this study is to direct computer users to use computers more carefully in terms of ergonomics. The user-interactive system developed for this purpose controls distance of the user to the screen and calculates the look angle and the time spent looking at the screen and provides audio or text format warning when necessary. It is thought that this system will reduce the health problems caused by the frequency of computer usage by encouraging individuals to use computers ergonomically.

  15. [Computer-assisted temporomandibular joint reconstruction.

    Science.gov (United States)

    Zwetyenga, N; Mommers, X-A; Cheynet, F

    2013-08-02

    Prosthetic replacement of TMJ is gradually becoming a common procedure because of good functional and aesthetic results and low morbidity. Prosthetic models available can be standard or custom-made. Custom-made prosthesis are usually reserved for complex cases, but we think that computer assistance for custom-made prosthesis should be indicated for each case because it gives a greater implant stability and fewer complications. Computer assistance will further enlarge TMJ prosthesis replacement indications. Copyright © 2013. Published by Elsevier Masson SAS.

  16. Early Childhood Teacher Candidates\\' Attitudes towards Computer and Computer Assisted Instruction

    OpenAIRE

    Oğuz, Evrim; Ellez, A. Murat; Akamca, Güzin Özyılmaz; Kesercioğlu, Teoman İ.; Girgin, Günseli

    2011-01-01

    The aim of this research is to evaluate preschool candidates’ attitudes towards computers andattitudes towards use of computer assisted instruction. The sample of this study includes 481 early childhoodeducation students who attended Dokuz Eylül University’s department of Early Childhood Education. Data werecollected by using “Scale of Computer Assisted Instruction Attitudes” developed by the Arslan (2006),“Computer Attitudes Scale” developed by Çelik & Bindak (2005) and “General Info...

  17. A computer-aided diagnostic and troubleshooting system for fuel cell power plants

    International Nuclear Information System (INIS)

    Unkle, C.R.

    1990-10-01

    This Interactive Computer-Aided Troubleshooting System (ICATS) was designed as a troubleshooting aid for the Tokyo Electric Power Company (TEPCO) 11-megawatt dc Module (DCM). ICATS represents an integration of the System Testability and Maintenance Program (STAMP reg-sign) and the Portable Interactive Troubleshooter (POINTER trademark) software packages developed by ARINC Research Corporation. ICATS was designed to aid in the fault isolation of shutdown conditions that may occur in the DCM during on-load operations and start-up, and hold conditions that may occur during start-up. ICATS may also be used to help fault-isolate a return-to-standby condition occurring from on-load operation of the DCM. This report describes the development of ICATS and the ICATS functional design. The unique features of STAMP and POINTER, which allow for diagnostic aids to be designed for systems not yet built and operating, are also described. 10 refs., 21 figs., 6 tabs

  18. Interfaces for Modular Surgical Planning and Assistance Systems

    OpenAIRE

    Gessat, Michael

    2010-01-01

    Modern surgery of the 21st century relies in many aspects on computers or, in a wider sense, digital data processing. Department administration, OR scheduling, billing, and - with increasing pervasion - patient data management are performed with the aid of so called Surgical Information Systems (SIS) or, more general, Hospital Information Systems (HIS). Computer Assisted Surgery (CAS) summarizes techniques which assist a surgeon in the preparation and conduction of surgical interventions...

  19. Nuclear power plant diagnostic system

    International Nuclear Information System (INIS)

    Prokop, K.; Volavy, J.

    1982-01-01

    Basic information is presented on diagnostic systems used at nuclear power plants with PWR reactors. They include systems used at the Novovoronezh nuclear power plant in the USSR, at the Nord power plant in the GDR, the system developed at the Hungarian VEIKI institute, the system used at the V-1 nuclear power plant at Jaslovske Bohunice in Czechoslovakia and systems of the Rockwell International company used in US nuclear power plants. These diagnostic systems are basically founded on monitoring vibrations and noise, loose parts, pressure pulsations, neutron noise, coolant leaks and acoustic emissions. The Rockwell International system represents a complex unit whose advantage is the on-line evaluation of signals which gives certain instructions for the given situation directly to the operator. The other described systems process signals using similar methods. Digitized signals only serve off-line computer analyses. (Z.M.)

  20. Intelligent Decisional Assistant that Facilitate the Choice of a Proper Computer System Applied in Busines

    Directory of Open Access Journals (Sweden)

    Nicolae MARGINEAN

    2009-01-01

    Full Text Available The choice of a proper computer system is not an easy task for a decider. One reason could be the present market development of computer systems applied in business. The big number of the Romanian market players determines a big number of computerized products, with a multitude of various properties. Our proposal tries to optimize and facilitate this decisional process within an e-shop where are sold IT packets applied in business, building an online decisional assistant, a special component conceived to facilitate the decision making needed for the selection of the pertinent IT package that fits the requirements of one certain business, described by the decider. The user interacts with the system as an online buyer that visit an e-shop where are sold IT package applied in economy.

  1. Diagnostic information management system for the evaluation of medical images

    Energy Technology Data Exchange (ETDEWEB)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina

    1985-04-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions.

  2. Diagnostic information management system for the evaluation of medical images

    International Nuclear Information System (INIS)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina.

    1985-01-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions. (author)

  3. On improving of efficiency of plasma diagnostics with the help of computer

    International Nuclear Information System (INIS)

    Temko, S.W.; Temko, K.W.; Kuz'min, S.K.

    1994-01-01

    The cloud of weakly ionized plasma contaminated by impurities is considered. Impurities are the large-size particles, resulting under influence of adhesion and coagulation. Impurities cause decrease conduction and increase of radiation energy losses. To precipitate impurities one can use ultrasonic coagulation. However, under the acting ultrasonics the turbulence arises and instabilities, disturbing the plasma state, can develop. To stabilize plasma state and to deposit impurities on the walls of gas-discharge camera one needs both the data on diagnostics and the results of calculations as well as the system of situation adaptive controlling. The situations are time-dependent plasma states. The control system is formed from the distributed microprocessors network and from controlling computer. Microprocessors are installed on diagnostic installations, on energy sources and on ultrasonic signals supplies. To improve reliability and refusal-stability of the control system an apparatus, program and time excessivenesses are used. An effective methods of diagnostics can be SHF-methods and laser diagnostics. To find optical calculating data the authors apply statistical thermodynamics of spatial clusters, which was proposed by the authors earlier. Computer compares under the given program the diagnostic data with the results of calculations and produces control responses both on power sources and on generators of ultrasonic signals

  4. Influence of computer tomography on radiological diagnostics of malignant tumors

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, P.; Glueck, E.; Siems, H.

    1981-01-01

    A survey is presented of the present status of cancer diagnostics in the following organs and organ systems: neurocranium, visceral cranium and base of skull, larynx and thyroid, thorax, pancreas, retroperitoneum, kidneys and adrenal glands, pelvis, and skeletal system. The rank of computer tomography is compared with those of other examination techniques.

  5. Computer-Assisted Linguistic Analysis of the Peshitta

    NARCIS (Netherlands)

    Roorda, D.; Talstra, Eep; Dyk, Janet; van Keulen, Percy; Sikkel, Constantijn; Bosman, H.J.; Jenner, K.D.; Bakker, Dirk; Volkmer, J.A.; Gutman, Ariel; van Peursen, Wido Th.

    2014-01-01

    CALAP (Computer-Assisted Linguistic Analysis of the Peshitta), a joint research project of the Peshitta Institute Leiden and the Werkgroep Informatica at the Vrije Universiteit Amsterdam (1999-2005) CALAP concerned the computer-assisted analysis of the Peshitta to Kings (Janet Dyk and Percy van

  6. Diagnostic omission errors in acute paediatric practice: impact of a reminder system on decision-making

    Directory of Open Access Journals (Sweden)

    Fisher Helen

    2006-11-01

    Full Text Available Abstract Background Diagnostic error is a significant problem in specialities characterised by diagnostic uncertainty such as primary care, emergency medicine and paediatrics. Despite wide-spread availability, computerised aids have not been shown to significantly improve diagnostic decision-making in a real world environment, mainly due to the need for prolonged system consultation. In this study performed in the clinical environment, we used a Web-based diagnostic reminder system that provided rapid advice with free text data entry to examine its impact on clinicians' decisions in an acute paediatric setting during assessments characterised by diagnostic uncertainty. Methods Junior doctors working over a 5-month period at four paediatric ambulatory units consulted the Web-based diagnostic aid when they felt the need for diagnostic assistance. Subjects recorded their clinical decisions for patients (differential diagnosis, test-ordering and treatment before and after system consultation. An expert panel of four paediatric consultants independently suggested clinically significant decisions indicating an appropriate and 'safe' assessment. The primary outcome measure was change in the proportion of 'unsafe' workups by subjects during patient assessment. A more sensitive evaluation of impact was performed using specific validated quality scores. Adverse effects of consultation on decision-making, as well as the additional time spent on system use were examined. Results Subjects attempted to access the diagnostic aid on 595 occasions during the study period (8.6% of all medical assessments; subjects examined diagnostic advice only in 177 episodes (30%. Senior House Officers at hospitals with greater number of available computer workstations in the clinical area were most likely to consult the system, especially out of working hours. Diagnostic workups construed as 'unsafe' occurred in 47/104 cases (45.2%; this reduced to 32.7% following system

  7. Computer Vision Malaria Diagnostic Systems—Progress and Prospects

    Directory of Open Access Journals (Sweden)

    Joseph Joel Pollak

    2017-08-01

    Full Text Available Accurate malaria diagnosis is critical to prevent malaria fatalities, curb overuse of antimalarial drugs, and promote appropriate management of other causes of fever. While several diagnostic tests exist, the need for a rapid and highly accurate malaria assay remains. Microscopy and rapid diagnostic tests are the main diagnostic modalities available, yet they can demonstrate poor performance and accuracy. Automated microscopy platforms have the potential to significantly improve and standardize malaria diagnosis. Based on image recognition and machine learning algorithms, these systems maintain the benefits of light microscopy and provide improvements such as quicker scanning time, greater scanning area, and increased consistency brought by automation. While these applications have been in development for over a decade, recently several commercial platforms have emerged. In this review, we discuss the most advanced computer vision malaria diagnostic technologies and investigate several of their features which are central to field use. Additionally, we discuss the technological and policy barriers to implementing these technologies in low-resource settings world-wide.

  8. Overview of MFTF supervisory control and diagnostics system software

    International Nuclear Information System (INIS)

    Ng, W.C.

    1979-01-01

    The Mirror Fusion Test Facility (MFTF) at the Lawrence Livermore Laboratory (LLL) is currently the largest mirror fusion research project in the world. Its Control and Diagnostics System is handled by a distributed computer network consisting of nine Interdata minicomputer systems and about 65 microprocessors. One of the design requirements is tolerance of single-point failure. If one of the computer systems becomes inoperative, the experiment can still be carried out, although the system responsiveness to operator command may be degraded. In a normal experiment cycle, the researcher can examine the result of the previous experiment, change any control parameter, fire a shot, collect four million bytes of diagnostics data, perform intershot analysis, and have the result presented - all within five minutes. The software approach adopted for the Supervisory Control and Diagnostics System features chief programmer teams and structured programming. Pascal is the standard programming language in this project

  9. TFTR diagnostic control and data acquisition system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-01-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development

  10. Computer-assisted design for scaling up systems based on DNA reaction networks.

    Science.gov (United States)

    Aubert, Nathanaël; Mosca, Clément; Fujii, Teruo; Hagiya, Masami; Rondelez, Yannick

    2014-04-06

    In the past few years, there have been many exciting advances in the field of molecular programming, reaching a point where implementation of non-trivial systems, such as neural networks or switchable bistable networks, is a reality. Such systems require nonlinearity, be it through signal amplification, digitalization or the generation of autonomous dynamics such as oscillations. The biochemistry of DNA systems provides such mechanisms, but assembling them in a constructive manner is still a difficult and sometimes counterintuitive process. Moreover, realistic prediction of the actual evolution of concentrations over time requires a number of side reactions, such as leaks, cross-talks or competitive interactions, to be taken into account. In this case, the design of a system targeting a given function takes much trial and error before the correct architecture can be found. To speed up this process, we have created DNA Artificial Circuits Computer-Assisted Design (DACCAD), a computer-assisted design software that supports the construction of systems for the DNA toolbox. DACCAD is ultimately aimed to design actual in vitro implementations, which is made possible by building on the experimental knowledge available on the DNA toolbox. We illustrate its effectiveness by designing various systems, from Montagne et al.'s Oligator or Padirac et al.'s bistable system to new and complex networks, including a two-bit counter or a frequency divider as well as an example of very large system encoding the game Mastermind. In the process, we highlight a variety of behaviours, such as enzymatic saturation and load effect, which would be hard to handle or even predict with a simpler model. We also show that those mechanisms, while generally seen as detrimental, can be used in a positive way, as functional part of a design. Additionally, the number of parameters included in these simulations can be large, especially in the case of complex systems. For this reason, we included the

  11. Computer Assisted Advising Tool (CAAT).

    Science.gov (United States)

    Matsen, Marie E.

    Lane Community College's Computer Assisted Advising Tool (CAAT) is used by counselors to assist students in developing a plan for the completion of a degree or certificate. CAAT was designed to facilitate student advisement from matriculation to graduation by comparing degree requirements with the courses completed by students. Three major sources…

  12. On-line diagnostics for a real time system

    International Nuclear Information System (INIS)

    Sreenivasan, P.

    1976-01-01

    The purpose of an on-line diagnostics is to infuse the ability of self diagnosing in an online computer to enhance its dependability in a real time system. Such a diagnostics evolved for the CDPS of the Fast Breeder Test Reactor at Kalpakkam is reported. The two phases of the diagnostics, i.e., the malfunction detection and post detection action are described in some detail. (A.K.)

  13. DIVA and DIAPO: two diagnostic knowledge based systems used for French nuclear power plants

    International Nuclear Information System (INIS)

    Porcheron, M.; Ricard, B.; Joussellin, A.

    1997-01-01

    In order to improve monitoring and diagnosis capabilities in nuclear power plants, Electricite de France (EDF) has designed an integrated monitoring and diagnosis assistance system: PSAD-Poste de Surveillance et d'Aide au Diagnostic. The development of such a sophisticated monitoring and data processing systems has emphasized the need for the addition of analysis and diagnosis assistance capabilities. Therefore, diagnostic knowledge based systems have been added to the functions monitored in PSAD: DIVA for turbine generators, and DIAPO for reactor coolant pumps. These systems were designed from a representation of the diagnostic reasoning process of experts and of the supporting knowledge. Diagnosis in both systems relies on an abduction reasoning process applied to component fault models and observations derived from their actual behavior, as provided by the monitoring functions. The basic theoretical elements of this diagnostic model are summarized in a first part. In a second part, DIVA and DIAPO specific elements are described

  14. Intelligent neural network diagnostic system

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2010-01-01

    Recently, artificial neural network (ANN) has made a significant mark in the domain of diagnostic applications. Neural networks are used to implement complex non-linear mappings (functions) using simple elementary units interrelated through connections with adaptive weights. The performance of the ANN is mainly depending on their topology structure and weights. Some systems have been developed using genetic algorithm (GA) to optimize the topology of the ANN. But, they suffer from some limitations. They are : (1) The computation time requires for training the ANN several time reaching for the average weight required, (2) Slowness of GA for optimization process and (3) Fitness noise appeared in the optimization of ANN. This research suggests new issues to overcome these limitations for finding optimal neural network architectures to learn particular problems. This proposed methodology is used to develop a diagnostic neural network system. It has been applied for a 600 MW turbo-generator as a case of real complex systems. The proposed system has proved its significant performance compared to two common methods used in the diagnostic applications.

  15. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    Science.gov (United States)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  16. Computer game assisted instruction and students' achievement in ...

    African Journals Online (AJOL)

    Computer game assisted instruction and students' achievement in social studies. ... This paper examines the effects of computer game assisted instructional method, student's achievement in social studies in ... AJOL African Journals Online.

  17. Computer-aided assessment of diagnostic images for epidemiological research

    Directory of Open Access Journals (Sweden)

    Gange Stephen J

    2009-11-01

    Full Text Available Abstract Background Diagnostic images are often assessed for clinical outcomes using subjective methods, which are limited by the skill of the reviewer. Computer-aided diagnosis (CAD algorithms that assist reviewers in their decisions concerning outcomes have been developed to increase sensitivity and specificity in the clinical setting. However, these systems have not been well utilized in research settings to improve the measurement of clinical endpoints. Reductions in bias through their use could have important implications for etiologic research. Methods Using the example of cortical cataract detection, we developed an algorithm for assisting a reviewer in evaluating digital images for the presence and severity of lesions. Available image processing and statistical methods that were easily implementable were used as the basis for the CAD algorithm. The performance of the system was compared to the subjective assessment of five reviewers using 60 simulated images. Cortical cataract severity scores from 0 to 16 were assigned to the images by the reviewers and the CAD system, with each image assessed twice to obtain a measure of variability. Image characteristics that affected reviewer bias were also assessed by systematically varying the appearance of the simulated images. Results The algorithm yielded severity scores with smaller bias on images where cataract severity was mild to moderate (approximately ≤ 6/16ths. On high severity images, the bias of the CAD system exceeded that of the reviewers. The variability of the CAD system was zero on repeated images but ranged from 0.48 to 1.22 for the reviewers. The direction and magnitude of the bias exhibited by the reviewers was a function of the number of cataract opacities, the shape and the contrast of the lesions in the simulated images. Conclusion CAD systems are feasible to implement with available software and can be valuable when medical images contain exposure or outcome information for

  18. Computer assisted diagnosis in renal nuclear medicine: rationale, methodology and interpretative criteria for diuretic renography

    Science.gov (United States)

    Taylor, Andrew T; Garcia, Ernest V

    2014-01-01

    The goal of artificial intelligence, expert systems, decision support systems and computer assisted diagnosis (CAD) in imaging is the development and implementation of software to assist in the detection and evaluation of abnormalities, to alert physicians to cognitive biases, to reduce intra and inter-observer variability and to facilitate the interpretation of studies at a faster rate and with a higher level of accuracy. These developments are needed to meet the challenges resulting from a rapid increase in the volume of diagnostic imaging studies coupled with a concurrent increase in the number and complexity of images in each patient data. The convergence of an expanding knowledge base and escalating time constraints increases the likelihood of physician errors. Errors are even more likely when physicians interpret low volume studies such as 99mTc-MAG3 diuretic scans where imagers may have had limited training or experience. Decision support systems include neural networks, case-based reasoning, expert systems and statistical systems. iRENEX (renal expert) is an expert system for diuretic renography that uses a set of rules obtained from human experts to analyze a knowledge base of both clinical parameters and quantitative parameters derived from the renogram. Initial studies have shown that the interpretations provided by iRENEX are comparable to the interpretations of a panel of experts. iRENEX provides immediate patient specific feedback at the time of scan interpretation, can be queried to provide the reasons for its conclusions and can be used as an educational tool to teach trainees to better interpret renal scans. iRENEX also has the capacity to populate a structured reporting module and generate a clear and concise impression based on the elements contained in the report; adherence to the procedural and data entry components of the structured reporting module assures and documents procedural competency. Finally, although the focus is CAD applied to

  19. The pedagogical effectiveness of ASR-based computer assisted pronunciation training

    NARCIS (Netherlands)

    Neri, A.

    2007-01-01

    Computer Assisted Pronunciation Training (CAPT) systems with Automatic Speech Recognition (ASR) technology have become increasingly popular to train pronunciation in the second language (L2). The advantage of these systems is the provision of a self-paced, stress-free type of training with automatic

  20. Diagnostic Neural Network Systems for the Electronic Circuits

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2014-01-01

    Neural Networks is one of the most important artificial intelligent approaches for solving the diagnostic processes. This research concerns with uses the neural networks for diagnosis of the electronic circuits. Modern electronic systems contain both the analog and digital circuits. But, diagnosis of the analog circuits suffers from great complexity due to their nonlinearity. To overcome this problem, the proposed system introduces a diagnostic system that uses the neural network to diagnose both the digital and analog circuits. So, it can face the new requirements for the modern electronic systems. A fault dictionary method was implemented in the system. Experimental results are presented on three electronic systems. They are: artificial kidney, wireless network and personal computer systems. The proposed system has improved the performance of the diagnostic systems when applied for these practical cases

  1. The Effects of Computer-assisted and Distance Learning of Geometric Modeling

    Directory of Open Access Journals (Sweden)

    Omer Faruk Sozcu

    2013-01-01

    Full Text Available The effects of computer-assisted and distance learning of geometric modeling and computer aided geometric design are studied. It was shown that computer algebra systems and dynamic geometric environments can be considered as excellent tools for teaching mathematical concepts of mentioned areas, and distance education technologies would be indispensable for consolidation of successfully passed topics

  2. Prototyping low-cost and flexible vehicle diagnostic systems

    Directory of Open Access Journals (Sweden)

    Marisol GARCÍA-VALLS

    2016-12-01

    Full Text Available Diagnostic systems are software and hardware-based equipment that interoperate with an external monitored system. Traditionally, they have been expensive equipment running test algorithms to monitor physical properties of, e.g., vehicles, or civil infrastructure equipment, among others. As computer hardware is increasingly powerful (whereas its cost and size is decreasing and communication software becomes easier to program and more run-time efficient, new scenarios are enabled that yield to lower cost monitoring solutions. This paper presents a low cost approach towards the development of a diagnostic systems relying on a modular component-based approach and running on a resource limited embedded computer. Results on a prototype implementation are shown that validate the presented design, its flexibility, performance, and communication latency.

  3. Computer-Assisted Discovery and Proof

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.; Borwein, Jonathan M.

    2007-12-10

    With the advent of powerful, widely-available mathematical software, combined with ever-faster computer hardware, we are approaching a day when both the discovery and proof of mathematical facts can be done in a computer-assisted manner. his article presents several specific examples of this new paradigm in action.

  4. Software for the diagnostic system of the secondary circuit of the Temelin nuclear power plant

    International Nuclear Information System (INIS)

    Drab, J.

    1990-01-01

    The secondary circuit of unit 1 of the Temelin nuclear power plant will be fitted with an automated diagnostic system, whose objects include the turbine and generator; feedwater pumps and their turbines; separator-reheater; condensers; low-pressure and high-pressure heaters; feedwater tank; and steam lines. The automated diagnostic system is divided into 5 subsystems, each containing a measuring unit controlled by a PC 286 computer. These computers are included in a LAN network with a PC 386 master computer. The software consists of 3 components, viz. ONSPEC for controlling the measuring unit, data evaluation and organization and for intercommunication within the LAN; diagnostic software for the diagnostic tests, of which a total of 23 are included; and communication software for transmitting the diagnostic test results to the unit control room and also for transmitting data from accurate sensors to the information computer system for technico-economic calculations. The whole system is open to future supplementing with additional software, diagnostic tests or diagnostic subsystems. (P.A.). 1 fig., 3 refs

  5. Virtual reality based surgical assistance and training system for long duration space missions.

    Science.gov (United States)

    Montgomery, K; Thonier, G; Stephanides, M; Schendel, S

    2001-01-01

    Access to medical care during long duration space missions is extremely important. Numerous unanticipated medical problems will need to be addressed promptly and efficiently. Although telemedicine provides a convenient tool for remote diagnosis and treatment, it is impractical due to the long delay between data transmission and reception to Earth. While a well-trained surgeon-internist-astronaut would be an essential addition to the crew, the vast number of potential medical problems necessitate instant access to computerized, skill-enhancing and diagnostic tools. A functional prototype of a virtual reality based surgical training and assistance tool was created at our center, using low-power, small, lightweight components that would be easy to transport on a space mission. The system consists of a tracked, head-mounted display, a computer system, and a number of tracked surgical instruments. The software provides a real-time surgical simulation system with integrated monitoring and information retrieval and a voice input/output subsystem. Initial medical content for the system has been created, comprising craniofacial, hand, inner ear, and general anatomy, as well as information on a number of surgical procedures and techniques. One surgical specialty in particular, microsurgery, was provided as a full simulation due to its long training requirements, significant impact on result due to experience, and likelihood for need. However, the system is easily adapted to realistically simulate a large number of other surgical procedures. By providing a general system for surgical simulation and assistance, the astronaut-surgeon can maintain their skills, acquire new specialty skills, and use tools for computer-based surgical planning and assistance to minimize overall crew and mission risk.

  6. The current status and future prospects of computer-assisted hip surgery.

    Science.gov (United States)

    Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-03-01

    The advances in computer assistance technology have allowed detailed three-dimensional preoperative planning and simulation of preoperative plans. The use of a navigation system as an intraoperative assistance tool allows more accurate execution of the preoperative plan, compared to manual operation without assistance of the navigation system. In total hip arthroplasty using CT-based navigation, three-dimensional preoperative planning with computer software allows the surgeon to determine the optimal angle of implant placement at which implant impingement is unlikely to occur in the range of hip joint motion necessary for daily activities of living, and to determine the amount of three-dimensional correction for leg length and offset. With the use of computer navigation for intraoperative assistance, the preoperative plan can be precisely executed. In hip osteotomy using CT-based navigation, the navigation allows three-dimensional preoperative planning, intraoperative confirmation of osteotomy sites, safe performance of osteotomy even under poor visual conditions, and a reduction in exposure doses from intraoperative fluoroscopy. Positions of the tips of chisels can be displayed on the computer monitor during surgery in real time, and staff other than the operator can also be aware of the progress of surgery. Thus, computer navigation also has an educational value. On the other hand, its limitations include the need for placement of trackers, increased radiation exposure from preoperative CT scans, and prolonged operative time. Moreover, because the position of a bone fragment cannot be traced after osteotomy, methods to find its precise position after its movement need to be developed. Despite the need to develop methods for the postoperative evaluation of accuracy for osteotomy, further application and development of these systems are expected in the future. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  7. Implementation of Computer Assisted Test Selection System in Local Governments

    Directory of Open Access Journals (Sweden)

    Abdul Azis Basri

    2016-05-01

    Full Text Available As an evaluative way of selection of civil servant system in all government areas, Computer Assisted Test selection system was started to apply in 2013. In phase of implementation for first time in all areas in 2014, this system selection had trouble in several areas, such as registration procedure and passing grade. The main objective of this essay was to describe implementation of new selection system for civil servants in the local governments and to seek level of effectiveness of this selection system. This essay used combination of study literature and field survey which data collection was made by interviews, observations, and documentations from various sources, and to analyze the collected data, this essay used reduction, display data and verification for made the conclusion. The result of this essay showed, despite there a few parts that be problem of this system such as in the registration phase but almost all phases of implementation of CAT selection system in local government areas can be said was working clearly likes in preparation, implementation and result processing phase. And also this system was fulfilled two of three criterias of effectiveness for selection system, they were accuracy and trusty. Therefore, this selection system can be said as an effective way to select new civil servant. As suggestion, local governments have to make prime preparation in all phases of test and make a good feedback as evaluation mechanism and together with central government to seek, fix and improve infrastructures as supporting tool and competency of local residents.

  8. Assessing the activity of perianal Crohn's disease: comparison of clinical indices and computer-assisted anal ultrasound.

    Science.gov (United States)

    Losco, Alessandra; Viganò, Chiara; Conte, Dario; Cesana, Bruno Mario; Basilisco, Guido

    2009-05-01

    Assessing perianal disease activity is important for the treatment and prognosis of Crohn's disease (CD) patients, but the diagnostic accuracy of the activity indices has not yet been established. The aim of this study was to determine the accuracy and agreement of the Fistula Drainage Assessment (FDA), Perianal Disease Activity Index (PDAI), and computer-assisted anal ultrasound imaging (AUS). Sixty-two consecutive patients with CD and perianal fistulae underwent clinical, FDA, PDAI, and AUS evaluation. Perianal disease was considered active in the presence of visible fistula drainage and/or signs of local inflammation (induration and pain at digital compression) upon clinical examination. The AUS images were analyzed by calculating the mean gray-scale tone of the lesion. The PDAI and gray-scale tone values discriminating active and inactive perianal disease were defined using receiver operating characteristics statistics. Perianal disease was active in 46 patients. The accuracy of the FDA was 87% (confidence interval [CI]: 76%-94%). A PDAI of >4 and a mean gray-scale tone value of 117 maximized sensitivity and specificity; their diagnostic accuracy was, respectively, 87% (CI: 76%-94%) and 81% (CI: 69%-90%). The agreement of the 3 evaluations was fair to moderate. The addition of AUS to the PDAI or FDA increased their diagnostic accuracy to respectively 95% and 98%. The diagnostic accuracy of the FDA, PDAI, and computer-assisted AUS imaging was good in assessing perianal disease activity in patients with CD. The agreement between the techniques was fair to moderate. Overall accuracy can be increased by combining the FDA or PDAI with AUS.

  9. Flat-detector computed tomography in diagnostic and interventional neuroradiology

    International Nuclear Information System (INIS)

    Struffert, T.; Doerfler, A.

    2009-01-01

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range than available with film-screen and phosphor luminescence, radiography flat detector technology is now widely accepted for neuroangiographic imaging. Especially flat-detector computed tomography (FD-CT), which uses rotational C-arm mounted flat-panel detector technology, is capable of volumetric imaging with a high spatial resolution. As ''angiographic CT'' FD-CT may be helpful in many diagnostic and neurointerventional procedures, e.g. intracranial stenting for cerebrovascular stenoses, stent-assisted coil embolization of wide-necked cerebral aneurysms and embolization of arteriovenous malformations. By providing morphologic, CT-like images of the brain within the angiography suite FD-CT allows rapid visualization of periprocedural hemorrhaging and may thus improve rapid complication management without the need of patient transfer. In addition, myelography and postmyelographic FD-CT imaging can be carried out using a single modality. Spinal interventions, such as kyphoplasty or vertebroplasty might also benefit from FD-CT. Imaging of the temporal bone may also develop into an important field of FD-CT. This paper briefly reviews the technical principles of FD technology and the potential applications in diagnostic and interventional neuroradiology. (orig.) [de

  10. Embedded systems for supporting computer accessibility.

    Science.gov (United States)

    Mulfari, Davide; Celesti, Antonio; Fazio, Maria; Villari, Massimo; Puliafito, Antonio

    2015-01-01

    Nowadays, customized AT software solutions allow their users to interact with various kinds of computer systems. Such tools are generally available on personal devices (e.g., smartphones, laptops and so on) commonly used by a person with a disability. In this paper, we investigate a way of using the aforementioned AT equipments in order to access many different devices without assistive preferences. The solution takes advantage of open source hardware and its core component consists of an affordable Linux embedded system: it grabs data coming from the assistive software, which runs on the user's personal device, then, after processing, it generates native keyboard and mouse HID commands for the target computing device controlled by the end user. This process supports any operating system available on the target machine and it requires no specialized software installation; therefore the user with a disability can rely on a single assistive tool to control a wide range of computing platforms, including conventional computers and many kinds of mobile devices, which receive input commands through the USB HID protocol.

  11. [Computer-assisted navigation in orthognathic surgery. Application to Le Fort I osteotomy.

    Science.gov (United States)

    Benassarou, M; Benassarou, A; Meyer, C

    2013-08-05

    Computer-assisted navigation is a tool that allows the surgeon to reach intraoperatively a previously defined target. This technique can be applied to the positioning of bone fragments in orthognathic surgery. It is not used routinely yet because there are no specifically dedicated systems available on the market for this kind of surgery. The goal of our study was to describe the various systems that could be used in orthognathic surgery and to report our experience of computer-assisted surgery in the positioning of the maxilla during maxillomandibular osteotomies. Copyright © 2013. Published by Elsevier Masson SAS.

  12. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  13. Effects of Computer-Assisted Instruction with Conceptual Change Texts on Removing the Misconceptions of Radioactivity

    Directory of Open Access Journals (Sweden)

    Ahmet YUMUŞAK

    2016-12-01

    Full Text Available Training young scientists, enabling conceptual understanding in science education is quite important. Misconception is one of the important indications for whether the concepts are understood or not. The most important educational tools to remove misconceptions are conceptual change texts. In addition, one of the important methods to remove misconceptions is computer-assisted instruction. The goal of this study is to research the effects of the use of computer-assisted instruction (CAI, conceptual change texts (CCT, computer-assisted instruction with conceptual change texts (CAI+CCT, and use of traditional teaching method (TTM on removing the misconceptions of science teacher candidates on the subject of radioactivity. Research sample was made of totally 92 students studying at four different groups of senior students in Celal Bayar University, Faculty of Education, Department of Science Education in 2011-2012 academic year. A different teaching method was used in each group. Experimental groups were randomly determined; in the first experimental group, computer-assisted instruction was used (23 students; in the second experimental group, conceptual change texts were used (23 students; in the third experimental group, computer-assisted instruction with conceptual change texts were used (23 students; and the fourth group, on which traditional education method was used, was called control group (23 students. Two-tier misconception diagnostic instrument, which was developed by the researcher, was used as data collection tool of the research. “Nonequivalent Control Groups Experimental Design” was used in this research in order to determine the efficiency of different teaching methods. Obtained data were analyzed by using SPSS 21.0. As a result of the research, it was determined that methods used on experimental groups were more successful than traditional teaching method practiced on control group in terms of removing misconceptions on

  14. Expert-systems and computer-based industrial systems

    International Nuclear Information System (INIS)

    Terrien, J.F.

    1987-01-01

    Framatome makes wide use of expert systems, computer-assisted engineering, production management and personnel training. It has set up separate business units and subsidiaries and also participates in other companies which have the relevant expertise. Five examples of the products and services available in these are discussed. These are in the field of applied artificial intelligence and expert-systems, in integrated computer-aid design and engineering, structural analysis, computer-related products and services and document management systems. The structure of the companies involved and the work they are doing is discussed. (UK)

  15. Terrace Layout Using a Computer Assisted System

    Science.gov (United States)

    Development of a web-based terrace design tool based on the MOTERR program is presented, along with representative layouts for conventional and parallel terrace systems. Using digital elevation maps and geographic information systems (GIS), this tool utilizes personal computers to rapidly construct ...

  16. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  17. A comparative analysis of multi-level computer-assisted decision making systems for traumatic injuries

    Directory of Open Access Journals (Sweden)

    Huynh Toan

    2009-01-01

    Full Text Available Abstract Background This paper focuses on the creation of a predictive computer-assisted decision making system for traumatic injury using machine learning algorithms. Trauma experts must make several difficult decisions based on a large number of patient attributes, usually in a short period of time. The aim is to compare the existing machine learning methods available for medical informatics, and develop reliable, rule-based computer-assisted decision-making systems that provide recommendations for the course of treatment for new patients, based on previously seen cases in trauma databases. Datasets of traumatic brain injury (TBI patients are used to train and test the decision making algorithm. The work is also applicable to patients with traumatic pelvic injuries. Methods Decision-making rules are created by processing patterns discovered in the datasets, using machine learning techniques. More specifically, CART and C4.5 are used, as they provide grammatical expressions of knowledge extracted by applying logical operations to the available features. The resulting rule sets are tested against other machine learning methods, including AdaBoost and SVM. The rule creation algorithm is applied to multiple datasets, both with and without prior filtering to discover significant variables. This filtering is performed via logistic regression prior to the rule discovery process. Results For survival prediction using all variables, CART outperformed the other machine learning methods. When using only significant variables, neural networks performed best. A reliable rule-base was generated using combined C4.5/CART. The average predictive rule performance was 82% when using all variables, and approximately 84% when using significant variables only. The average performance of the combined C4.5 and CART system using significant variables was 89.7% in predicting the exact outcome (home or rehabilitation, and 93.1% in predicting the ICU length of stay for

  18. Virtual tutor systems for robot-assisted instruction

    Science.gov (United States)

    Zhao, Zhijing; Zhao, Deyu; Zhang, Zizhen; Wei, Yongji; Qi, Bingchen; Okawa, Yoshikuni

    2004-03-01

    Virtual Reality technology belongs to advanced computer technology, it has been applied in instruction field and gains obvious effect. At the same time, robot assisted instruction comes true with the continuous development of Robot technology and artificial intelligence technology. This paper introduces a virtual tutor system for robot assisted instruction.

  19. The influence of computer tomography on radiological diagnostics of malignant tumors

    International Nuclear Information System (INIS)

    Gerhardt, P.; Glueck, E.; Siems, H.

    1981-01-01

    A survey is presented of the present status of cancer diagnostics in the following organs and organ systems: neurocranium, visceral cranium and base of skull, larynx and thyroid, thorax, pancreas, retroperitoneum, kidneys and adrenal glands, pelvis, and skeletal system. The rank of computer tomography is compared with those of other examination techniques. (HT) [de

  20. Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings

    International Nuclear Information System (INIS)

    Marten, Katharina; Grillhoesl, Andreas; Seyfarth, Tobias; Rummeny, Ernst J.; Engelke, Christoph; Obenauer, Silvia

    2005-01-01

    The purpose of this study was to evaluate the performance of a computer-assisted diagnostic (CAD) tool using various reconstruction slice thicknesses (RST). Image data of 20 patients undergoing multislice CT for pulmonary metastasis were reconstructed at 4.0, 2.0 and 0.75 mm RST and assessed by two blinded radiologists (R1 and R2) and CAD. Data were compared against an independent reference standard. Nodule subgroups (diameter >10, 4-10, <4 mm) were assessed separately. Statistical methods were the ROC analysis and Mann-Whitney Utest. CAD was outperformed by readers at 4.0 mm (Az = 0.18, 0.62 and 0.69 for CAD, R1 and R2, respectively; P<0.05), comparable at 2.0 mm (Az = 0.57, 0.70 and 0.69 for CAD, R1 and R2, respectively), and superior using 0.75 mm RST (Az = 0.80, 0.70 and 0.70 and sensitivity = 0.74, 0.53 and 0.53 for CAD, R1 and R2, respectively; P<0.05). Reader performances were significantly enhanced by CAD (Az = 0.93 and 0.95 for R1 + CAD and R2 + CAD, respectively, P<0.05). The CAD advantage was best for nodules <10 mm (detection rates = 93.3, 89.9, 47.9 and 47.9% for R1 + CAD, R2 + CAD, R1 and R2, respectively). CAD using 0.75 mm RST outperformed radiologists in nodules below 10 mm in diameter and should be used to replace a second radiologist. CAD is not recommended for 4.0 mm RST. (orig.)

  1. Evaluation of automatic exposure control systems in computed tomography

    International Nuclear Information System (INIS)

    Reina, Thamiris Rosado

    2014-01-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  2. Evaluation of automatic exposure control systems in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Reina, Thamiris Rosado

    2014-07-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  3. Development and refinement of computer-assisted planning and execution system for use in face-jaw-teeth transplantation to improve skeletal and dento-occlusal outcomes.

    Science.gov (United States)

    Hashemi, Sepehr; Armand, Mehran; Gordon, Chad R

    2016-10-01

    To describe the development and refinement of the computer-assisted planning and execution (CAPE) system for use in face-jaw-teeth transplants (FJTTs). Although successful, some maxillofacial transplants result in suboptimal hybrid occlusion and may require subsequent surgical orthognathic revisions. Unfortunately, the use of traditional dental casts and splints pose several compromising shortcomings in the context of FJTT and hybrid occlusion. Computer-assisted surgery may overcome these challenges. Therefore, the use of computer-assisted orthognathic techniques and functional planning may prevent the need for such revisions and improve facial-skeletal outcomes. A comprehensive CAPE system for use in FJTT was developed through a multicenter collaboration and refined using plastic models, live miniature swine surgery, and human cadaver models. The system marries preoperative surgical planning and intraoperative execution by allowing on-table navigation of the donor fragment relative to recipient cranium, and real-time reporting of patient's cephalometric measurements relative to a desired dental-skeletal outcome. FJTTs using live-animal and cadaveric models demonstrate the CAPE system to be accurate in navigation and beneficial in improving hybrid occlusion and other craniofacial outcomes. Future refinement of the CAPE system includes integration of more commonly performed orthognathic/maxillofacial procedures.

  4. Using a Touch-Based, Computer-Assisted Learning System to Promote Literacy and Math Skills for Low-Income Preschoolers

    Directory of Open Access Journals (Sweden)

    Mark H McManis

    2016-08-01

    Full Text Available The use of touch-based technologies by young children to improve academic skills has seen growth outpacing empirical evidence of its effectiveness. Due to the educational challenges low-income children face, the stakes for providing instructional technology with demonstrated efficacy are high. The current work presents an empirical study of the use of a touch-based, computer-assisted learning system by low-income preschoolers. A description of the system’s design is provided with attention to young children’s interaction with touch devices, learner engagement, and pedagogically-based delivery of academic content. Children in 18 low-income child-care preschool classrooms were assessed on literacy and math skills in the fall and again in the spring. Target children used the iStartSmart learning system throughout the academic year, while control children did not have access to the system. Compared to controls, children using the learning system made significant gains on external standardized measures of literacy and math. Children who spent more time using the system and those who reached the upper levels of skill understanding showed the strongest improvement in test scores. The findings contribute to the currently sparse literature by illuminating that for at-risk early learners, touch-based, computer-assisted instructional technology shows promise as an educational tool.

  5. Computer-assisted nuclear fuel manufacture

    International Nuclear Information System (INIS)

    Maloney, J.P.; Schaumann, S.M.; Stone, E.

    1976-01-01

    At the ERDA Savannah River Plant, a process monitor, which incorporates an online digital computer, assists in manufacturing fuel elements used to produce nuclides such as plutonium, tritium, and californium in the plant's nuclear reactors. Also, inventory functions assist in safeguarding fissile material and protecting against accidental nuclear criticality. Terminals at strategic locations throughout the process area enable production operators to send and receive instructions and information on each manufacturing step

  6. General review of diagnostic systems in EDF PWR units

    International Nuclear Information System (INIS)

    Chevalier, R.; Brasseur, S.; Ricard, B.

    1998-01-01

    Since the beginning of the French nuclear program, Electricite de France (EDF) has looked for ways to improve the availability and safety of its nuclear units. Therefore, monitoring systems on turbogenerators, reactor coolant pumps, primary circuits and core internal structures were designed by the Research and Development Division and implemented with technologies available during the 1970's. However, mainly because of difficulties for data interpretation by plant personnel, EDF subsequently decided to design and develop different tools to help plant operators to process a diagnosis: - a new generation of the Monitoring and Diagnostic System called PSAD, - expert systems for diagnosis on reactor coolant pumps (RCP) 'DIAPO' and turbogenerator units (TG) 'DIVA', - diagnostic guides written for most equipment pending the installation of new monitoring and diagnosis systems. The first version of PSAD, installed in five units, performs on-line monitoring of the turbogenerator shaft line, steam inlet valves, the reactor coolant pumps and the generator stator. The second version not yet implemented, will include Loose Part Detection (LPD) and Core Internal Structure Monitoring (CISM). The level of diagnosis achieved by PSAD depends on the component monitored. The TG and RCP monitoring functions of PSAD compute high level diagnosis descriptors such as natural frequencies and long term trends but do not elaborate a diagnosis automatically. However, a diagnostic assistance window is available on-line, whenever a warning message is displayed, whether for immediate or later action. The window presents a diagnostic approach whose purpose is to find the causes of the symptoms observed. This diagnosis approach is automated in the DIVA and DIAPO expert systems. Numerous potential faults can be identified for both systems thanks to a hierarchy of abnormal situations. The user interactively answers questions when information is needed to progress in the diagnosis. The resulting

  7. Existence and instability of steady states for a triangular cross-diffusion system: A computer-assisted proof

    Science.gov (United States)

    Breden, Maxime; Castelli, Roberto

    2018-05-01

    In this paper, we present and apply a computer-assisted method to study steady states of a triangular cross-diffusion system. Our approach consist in an a posteriori validation procedure, that is based on using a fixed point argument around a numerically computed solution, in the spirit of the Newton-Kantorovich theorem. It allows to prove the existence of various non homogeneous steady states for different parameter values. In some situations, we obtain as many as 13 coexisting steady states. We also apply the a posteriori validation procedure to study the linear stability of the obtained steady states, proving that many of them are in fact unstable.

  8. New patient pathway using vacuum-assisted biopsy reduces diagnostic surgery for B3 lesions

    International Nuclear Information System (INIS)

    Rajan, S.; Shaaban, A.M.; Dall, B.J.G.; Sharma, N.

    2012-01-01

    Aim: To assess the clinical impact of a new patient management pathway incorporating vacuum-assisted biopsy for lesions of uncertain malignant potential (B3). Materials and methods: A retrospective analysis was undertaken of all B3 lesions on core biopsy in the pathology database from April 2008 to April 2010. Outcome measures assessed included final histological diagnosis, frequency of diagnostic surgical biopsy, and impact on management. Results: In the old pathway, there were 95 B3 lesions, of which 14% (13/95) were planned for vacuum-assisted biopsy and 86% (82/95) for surgical biopsy. In the new pathway, there were 94 B3 lesions, of which 68% (64/94) were planned for vacuum-assisted biopsy and 32% (30/94) for surgical biopsy. Following further sampling with vacuum-assisted biopsy, only 13% of patients required diagnostic surgical biopsy and in 25% of cases, a preoperative diagnosis of carcinoma was reached allowing patients to proceed to therapeutic surgery. Conclusion: The new pathway has reduced the number of benign diagnostic surgical biopsies performed and increased the preoperative diagnosis of breast cancer.

  9. About the Big Graphs Arising when Forming the Diagnostic Models in a Reconfigurable Computing Field of Functional Monitoring and Diagnostics System of the Spacecraft Onboard Control Complex

    Directory of Open Access Journals (Sweden)

    L. V. Savkin

    2015-01-01

    Full Text Available One of the problems in implementation of the multipurpose complete systems based on the reconfigurable computing fields (RCF is the problem of optimum redistribution of logicalarithmetic resources in growing scope of functional tasks. Irrespective of complexity, all of them are transformed into an orgraph, which functional and topological structure is appropriately imposed on the RCF based, as a rule, on the field programmable gate array (FPGA.Due to limitation of the hardware configurations and functions realized by means of the switched logical blocks (SLB, the abovementioned problem becomes even more critical when there is a need, within the strictly allocated RCF fragment, to realize even more complex challenge in comparison with the problem which was solved during the previous computing step. In such cases it is possible to speak about graphs of big dimensions with respect to allocated RCF fragment.The article considers this problem through development of diagnostic algorithms to implement diagnostics and control of an onboard control complex of the spacecraft using RCF. It gives examples of big graphs arising with respect to allocated RCF fragment when forming the hardware levels of a diagnostic model, which, in this case, is any hardware-based algorithm of diagnostics in RCF.The article reviews examples of arising big graphs when forming the complicated diagnostic models due to drastic difference in formation of hardware levels on closely located RCF fragments. It also pays attention to big graphs emerging when the multichannel diagnostic models are formed.Three main ways to solve the problem of big graphs with respect to allocated RCF fragment are given. These are: splitting the graph into fragments, use of pop-up windows with relocating and memorizing intermediate values of functions of high hardware levels of diagnostic models, and deep adaptive update of diagnostic model.It is shown that the last of three ways is the most efficient

  10. Computer-assisted nuclear fuel manufacture

    International Nuclear Information System (INIS)

    Maloney, J.P.; Schaumann, C.M.; Stone, E.

    1976-06-01

    At the ERDA Savannah River Plant, a process monitor, which incorporates an online digital computer, assists in manufacturing fuel elements used to produce nuclides such as plutonium, tritium, and californium in the plant's nuclear reactors. Also, inventory functions assist in safeguarding fissile material and protecting against accidental nuclear criticality. Terminals at strategic locations throughout the process area enable production operators to send and receive instructions and information on each manufacturing step. 11 fig

  11. Performance diagnostic system for emergency diesel generators

    International Nuclear Information System (INIS)

    Logan, K.P.

    1991-01-01

    Diesel generators are commonly used for emergency backup power at nuclear stations. Emergency diesel generators (EDGs) are subject to both start-up and operating failures, due to infrequent and fast-start use. EDG reliability can be critical to plant safety, particularly when station blackout occurs. This paper describes an expert diagnostic system designed to consistently evaluate the operating performance of diesel generators. The prototype system is comprised of a suite of sensor monitoring, cylinder combustion analyzing, and diagnostic workstation computers. On-demand assessments of generator and auxiliary equipment performance are provided along with color trend displays comparing measured performance to reference-normal conditions

  12. Competency Reference for Computer Assisted Drafting.

    Science.gov (United States)

    Oregon State Dept. of Education, Salem. Div. of Vocational Technical Education.

    This guide, developed in Oregon, lists competencies essential for students in computer-assisted drafting (CAD). Competencies are organized in eight categories: computer hardware, file usage and manipulation, basic drafting techniques, mechanical drafting, specialty disciplines, three dimensional drawing/design, plotting/printing, and advanced CAD.…

  13. Shiva and Argus target diagnostics vacuum systems

    International Nuclear Information System (INIS)

    Glaros, S.S.; Mayo, S.E.; Campbell, D.; Holeman, D.

    1978-09-01

    The normal operation of LLL's Argus and Shiva laser irradiation facilities demand a main vacuum system for the target chamber and a separate local vacuum system for each of the larger appendage dianostics. This paper will describe the Argus and Shiva main vacuum systems, their respective auxiliary vacuum systems and the individual diagnostics with their respective special vacuum requirements and subsequent vacuum systems. Our latest approach to automatic computer-controlled vacuum systems will be presented

  14. CARS 2009. Computer assisted radiology and surgery. Proceedings

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    The CARS 2009 proceedings include contributions and poster sessions concerning different conferences and workshops: computer assisted radiology, 23rd international congress and exhibition, CARS clinical day, 13th annual conference of the international society for computer aided surgery, 10th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, 11th international workshop on computer-aided diagnosis, 15th computed maxillofacial imaging congress, CARS - computer assisted radiology and surgery, 1st EPMA/CARS workshop on personalized medicine and ICT, JICARS - Japanese institutes of CARS, 1st EuroNotes/CTAC/CARS workshop on NOTES: an interdisciplinary challenge, 13th annual conference for computer aided surgery, 27th international EuroPACS meeting.

  15. Broadcast Copywriting and Computer Assisted Instruction.

    Science.gov (United States)

    Hagerman, William L.

    The teaching of broadcast copywriting can be enhanced by computer assisted instruction, especially in screening students' writing for adherence to classic "formulas" or "rules" for broadcast writing. Such rules might include avoiding cliches or not beginning a sentence with a subordinate clause. Other rules the computer can…

  16. [Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering].

    Science.gov (United States)

    Günther, P; Tröger, J; Holland-Cunz, S; Waag, K L; Schenk, J P

    2006-08-01

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this.A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning.

  17. Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering

    International Nuclear Information System (INIS)

    Guenther, P.; Holland-Cunz, S.; Waag, K.L.

    2006-01-01

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this. A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning. (orig.) [de

  18. A Multidisciplinary Model for Development of Intelligent Computer-Assisted Instruction.

    Science.gov (United States)

    Park, Ok-choon; Seidel, Robert J.

    1989-01-01

    Proposes a schematic multidisciplinary model to help developers of intelligent computer-assisted instruction (ICAI) identify the types of required expertise and integrate them into a system. Highlights include domain types and expertise; knowledge acquisition; task analysis; knowledge representation; student modeling; diagnosis of learning needs;…

  19. Computer assisted holographic moire contouring

    Science.gov (United States)

    Sciammarella, Cesar A.

    2000-01-01

    Theoretical analyses and experimental results on holographic moire contouring on diffusely reflecting objects are presented. The sensitivity and limitations of the method are discussed. Particular emphasis is put on computer-assisted data retrieval, processing, and recording.

  20. Constitution and application of reactor make-up system's fault diagnostic Bayesian networks

    International Nuclear Information System (INIS)

    Liang Jie; Cai Qi; Chu Zhuli; Wang Haiping

    2013-01-01

    A fault diagnostic Bayesian network of reactor make-up system was constituted. The system's structure characters, operation rules and experts' experience were combined and an initial net was built. As the fault date sets were learned with the particle swarm optimization based Bayesian network structure, the structure of diagnostic net was completed and used to inference case. The built net can analyze diagnostic probability of every node in the net and afford assistant decision to fault diagnosis. (authors)

  1. Computer-assisted power plant management

    International Nuclear Information System (INIS)

    Boettcher, D.

    1990-01-01

    Operating a power plant and keeping it operational is ensured by a multiplicity of technical management subtasks which are cross referenced and based on an extensive inventory of descriptive and operational plant data. These data stocks are still registered in an isolated mode and managed and updated manually. This is a labor intensive, error prone procedure. In this situation, the introduction of a computer-assisted plant management system, whose core is a data-base of assured quality common to all activities, and which contains standardized processing aids fully planned for the subtasks occurring in the plant, is likely to achieve a considerable improvement in the quality of plant management and to relieve the staff of administrative activities. (orig.) [de

  2. The use of computer graphics to assist in-reactor operations

    International Nuclear Information System (INIS)

    Smith, A.L.

    1995-01-01

    A number of complex inspection and repair tasks have been carried out inside Nuclear Electric's gas cooled reactors using multi-link manipulators. The paper describes how computer graphics are integrated into the manipulator system and perform a key role during many phases of a project. Graphics simulation is used to assist with conceptual design, detailed path planning, rehearsals, quality assurance, demonstrations and, critically, as an on-line tool to assist the real-time operation of the equipment whilst performing complex in-reactor tasks. The techniques used are illustrated by recent examples of use to assist the inspection and repair of in-reactor components. (Author)

  3. Computer Assisted Drafting (CNC) Drawings. Drafting Module 6. Instructor's Guide.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This Missouri Vocational Instruction Management System instructor's drafting guide has been keyed to the drafting competency profile developed by state industry and education professionals. This unit contains information on computer-assisted drafting drawings. The guide contains a cross-reference table of instructional materials and 20 worksheets.…

  4. System theory in medical diagnostic devices: an overview.

    Science.gov (United States)

    Baura, Gail D

    2006-01-01

    Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.

  5. Computer-assisted analysis of peripheral zone prostate lesions using T2-weighted and dynamic contrast enhanced T1-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Pieter C; Hambrock, Thomas; Barenstz, Jelle O; Huisman, Henkjan J [Department of Radiology, Radboud University Medical Centre, Nijmegen, 6525GA (Netherlands)], E-mail: p.vos@rad.umcn.nl

    2010-03-21

    In this study, computer-assisted analysis of prostate lesions was researched by combining information from two different magnetic resonance (MR) modalities: T2-weighted (T2-w) and dynamic contrast-enhanced (DCE) T1-w images. Two issues arise when incorporating T2-w images in a computer-aided diagnosis (CADx) system: T2-w values are position as well as sequence dependent and images can be misaligned due to patient movement during the acquisition. A method was developed that computes T2 estimates from a T2-w and proton density value and a known sequence model. A mutual information registration strategy was implemented to correct for patient movement. Global motion is modelled by an affine transformation, while local motion is described by a volume preserving non-rigid deformation based on B-splines. The additional value to the discriminating performance of a DCE T1-w-based CADx system was evaluated using bootstrapped ROC analysis. T2 estimates were successfully computed in 29 patients. T2 values were extracted and added to the CADx system from 39 malignant, 19 benign and 29 normal annotated regions. T2 values alone achieved a diagnostic accuracy of 0.85 (0.77-0.92) and showed a significantly improved discriminating performance of 0.89 (0.81-0.95), when combined with DCE T1-w features. In conclusion, the study demonstrated a simple T2 estimation method that has a diagnostic performance such that it complements a DCE T1-w-based CADx system in discriminating malignant lesions from normal and benign regions. Additionally, the T2 estimate is beneficial to visual inspection due to the removed coil profile and fixed window and level settings.

  6. A novel approach for computer assisted EEG monitoring in the adult ICU

    NARCIS (Netherlands)

    Cloostermans, M.C.; de Vos, Cecilia Cecilia Clementine; van Putten, Michel Johannes Antonius Maria

    2011-01-01

    Objective The implementation of a computer assisted system for real-time classification of the electroencephalogram (EEG) in critically ill patients. Methods Eight quantitative features were extracted from the raw EEG and combined into a single classifier. The system was trained with 41 EEG

  7. Augmented Reality Based Navigation for Computer Assisted Hip Resurfacing: A Proof of Concept Study.

    Science.gov (United States)

    Liu, He; Auvinet, Edouard; Giles, Joshua; Rodriguez Y Baena, Ferdinando

    2018-05-23

    Implantation accuracy has a great impact on the outcomes of hip resurfacing such as recovery of hip function. Computer assisted orthopedic surgery has demonstrated clear advantages for the patients, with improved placement accuracy and fewer outliers, but the intrusiveness, cost, and added complexity have limited its widespread adoption. To provide seamless computer assistance with improved immersion and a more natural surgical workflow, we propose an augmented-reality (AR) based navigation system for hip resurfacing. The operative femur is registered by processing depth information from the surgical site with a commercial depth camera. By coupling depth data with robotic assistance, obstacles that may obstruct the femur can be tracked and avoided automatically to reduce the chance of disruption to the surgical workflow. Using the registration result and the pre-operative plan, intra-operative surgical guidance is provided through a commercial AR headset so that the user can perform the operation without additional physical guides. To assess the accuracy of the navigation system, experiments of guide hole drilling were performed on femur phantoms. The position and orientation of the drilled holes were compared with the pre-operative plan, and the mean errors were found to be approximately 2 mm and 2°, results which are in line with commercial computer assisted orthopedic systems today.

  8. Interactive computer-assisted instruction in acid-base physiology for mobile computer platforms.

    Science.gov (United States)

    Longmuir, Kenneth J

    2014-03-01

    In this project, the traditional lecture hall presentation of acid-base physiology in the first-year medical school curriculum was replaced by interactive, computer-assisted instruction designed primarily for the iPad and other mobile computer platforms. Three learning modules were developed, each with ∼20 screens of information, on the subjects of the CO2-bicarbonate buffer system, other body buffer systems, and acid-base disorders. Five clinical case modules were also developed. For the learning modules, the interactive, active learning activities were primarily step-by-step learner control of explanations of complex physiological concepts, usually presented graphically. For the clinical cases, the active learning activities were primarily question-and-answer exercises that related clinical findings to the relevant basic science concepts. The student response was remarkably positive, with the interactive, active learning aspect of the instruction cited as the most important feature. Also, students cited the self-paced instruction, extensive use of interactive graphics, and side-by-side presentation of text and graphics as positive features. Most students reported that it took less time to study the subject matter with this online instruction compared with subject matter presented in the lecture hall. However, the approach to learning was highly examination driven, with most students delaying the study of the subject matter until a few days before the scheduled examination. Wider implementation of active learning computer-assisted instruction will require that instructors present subject matter interactively, that students fully embrace the responsibilities of independent learning, and that institutional administrations measure instructional effort by criteria other than scheduled hours of instruction.

  9. Computer Assisted Audit Techniques

    Directory of Open Access Journals (Sweden)

    Eugenia Iancu

    2007-01-01

    Full Text Available From the modern point of view, audit takes intoaccount especially the information systems representingmainly the examination performed by a professional asregards the manner for developing an activity by means ofcomparing it to the quality criteria specific to this activity.Having as reference point this very general definition ofauditing, it must be emphasized that the best known segmentof auditing is the financial audit that had a parallel evolutionto the accountancy one.The present day phase of developing the financial audithas as main trait the internationalization of the accountantprofessional. World wide there are multinational companiesthat offer services in the financial auditing, taxing andconsultancy domain. The auditors, natural persons and auditcompanies, take part at the works of the national andinternational authorities for setting out norms in theaccountancy and auditing domain.The computer assisted audit techniques can be classified inseveral manners according to the approaches used by theauditor. The most well-known techniques are comprised inthe following categories: testing data techniques, integratedtest, parallel simulation, revising the program logics,programs developed upon request, generalized auditsoftware, utility programs and expert systems.

  10. Fully automatic diagnostic system for early- and late-onset mild Alzheimer's disease using FDG PET and 3D-SSP

    International Nuclear Information System (INIS)

    Ishii, Kazunari; Kono, Atsushi K.; Sasaki, Hiroki; Miyamoto, Naokazu; Fukuda, Tetsuya; Sakamoto, Setsu; Mori, Etsuro

    2006-01-01

    The purpose of this study was to design a fully automatic computer-assisted diagnostic system for early- and late-onset mild Alzheimer's disease (AD). Glucose metabolic images were obtained from mild AD patients and normal controls using positron emission tomography (PET) and 18 F-fluorodeoxyglucose (FDG). Two groups of 20 mild AD patients with different ages of onset were examined. A fully automatic diagnostic system using the statistical brain mapping method was established from the early-onset (EO) and late-onset (LO) groups, with mean ages of 59.1 and 70.9 years and mean MMSE scores of 23.3 and 22.8, respectively. Aged-matched normal subjects were used as controls. We compared the diagnostic performance of visual inspection of conventional axial FDG PET images by experts and beginners with that of our fully automatic diagnostic system in another 15 EO and 15 LO AD patients (mean age 58.4 and 71.7, mean MMSE 23.6 and 23.1, respectively) and 30 age-matched normal controls. A receiver operating characteristic (ROC) analysis was performed to compare data. The diagnostic performance of the automatic diagnostic system was comparable with that of visual inspection by experts. The area under the ROC curve for the automatic diagnostic system was 0.967 for EO AD patients and 0.878 for LO AD patients. The mean area under the ROC curve for visual inspection by experts was 0.863 and 0.881 for the EO and LO AD patients, respectively. The mean area under the ROC curve for visual inspection by beginners was 0.828 and 0.717, respectively. The fully automatic diagnostic system for EO and LO AD was able to perform at a similar diagnostic level to visual inspection of conventional axial images by experts. (orig.)

  11. Incorporating computer-assisted assessment to Bachelor of Science ...

    African Journals Online (AJOL)

    The use of computers in education has already been established for decades. Computers have been used from lesson preparations, presentations, and student assessments. Many authors have studied the design, implementation, and impact of computer-assisted assessment (CAA) (also called computer-based testing, ...

  12. Accuracy of computer-assisted cervicle pedicle screw installation

    International Nuclear Information System (INIS)

    Zhang Honglei; Zhou Dongsheng; Jang Zhensong

    2009-01-01

    Objective: To investigate the accuracy of computer-assisted cervical pedicle screw installation and the reason of screw malposition. Methods: A total of 172 cervical pedicle screws were installed by computer-assisted navigation for 30 patients with lower cervical spinal diseases. All the patients were examined by X-ray and CT after operation. Screw's position and direction were measured on the sagittal and transectional images of intraoperative navigation and post-operative CT. Then linear regression analysis was taken between navigational and post-operative CT's images. Results: Two screws perforated the upper pedicle wall, 3 perforated the lateral pedicle wall.There was a positive linear correlation between navigational and post-operative CT's images. Conclusion: Computer-assisted navigation can provide the high accuracy of cervical pedicle screw installation and excursion phenomenon is reason of screw malposition. (authors)

  13. Symptom based diagnostic system using artificial neural networks

    International Nuclear Information System (INIS)

    Santosh; Vinod, Gopika; Saraf, R.K.

    2003-01-01

    Nuclear power plant experiences a number of transients during its operations. In case of such an undesired plant condition generally known as an initiating event, the operator has to carry out diagnostic and corrective actions. The operator's response may be too late to mitigate or minimize the negative consequences in such scenarios. The objective of this work is to develop an operator support system based on artificial neural networks that will assist the operator to identify the initiating events at the earliest stages of their developments. A symptom based diagnostic system has been developed to investigate the initiating events. Neutral networks are utilized for carrying out the event identification by continuously monitoring process parameters. Whenever an event is detected, the system will display the necessary operator actions along with the initiating event. The system will also show the graphical trend of process parameters that are relevant to the event. This paper describes the features of the software that is used to monitor the reactor. (author)

  14. Computer Assisted Testing of Spoken English: A Study of the SFLEP College English Oral Test System in China

    Directory of Open Access Journals (Sweden)

    John Lowe

    2009-06-01

    Full Text Available This paper reports on the on-going evaluation of a computer-assisted system (CEOTS for the assessing of spoken English skills among Chinese university students. This system is being developed to deal with the negative backwash effects of the present system of assessment of speaking skills which is only available to a tiny minority. We present data from a survey of students at the developing institution (USTC, with follow-up interviews and further interviews with English language teachers, to gauge the reactions to the test and its impact on language learning. We identify the key issue as being one of validity, with a tension existing between construct and consequential validities of the existing system and of CEOTS. We argue that a computer-based system seems to offer the only solution to the negative backwash problem but the development of the technology required to meet current construct validity demands makes this a very long term prospect. We suggest that a compromise between the competing forms of validity must therefore be accepted, probably well before a computer-based system can deliver the level of interaction with the examinees that would emulate the present face-to-face mode.

  15. Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Stockmans Filip

    2010-12-01

    Full Text Available Abstract Background Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides. Methods/Design This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months

  16. Computer-Vision-Assisted Palm Rehabilitation With Supervised Learning.

    Science.gov (United States)

    Vamsikrishna, K M; Dogra, Debi Prosad; Desarkar, Maunendra Sankar

    2016-05-01

    Physical rehabilitation supported by the computer-assisted-interface is gaining popularity among health-care fraternity. In this paper, we have proposed a computer-vision-assisted contactless methodology to facilitate palm and finger rehabilitation. Leap motion controller has been interfaced with a computing device to record parameters describing 3-D movements of the palm of a user undergoing rehabilitation. We have proposed an interface using Unity3D development platform. Our interface is capable of analyzing intermediate steps of rehabilitation without the help of an expert, and it can provide online feedback to the user. Isolated gestures are classified using linear discriminant analysis (DA) and support vector machines (SVM). Finally, a set of discrete hidden Markov models (HMM) have been used to classify gesture sequence performed during rehabilitation. Experimental validation using a large number of samples collected from healthy volunteers reveals that DA and SVM perform similarly while applied on isolated gesture recognition. We have compared the results of HMM-based sequence classification with CRF-based techniques. Our results confirm that both HMM and CRF perform quite similarly when tested on gesture sequences. The proposed system can be used for home-based palm or finger rehabilitation in the absence of experts.

  17. Design and implementation of a Macintosh-CAMAC based system for neutral beam diagnostics

    International Nuclear Information System (INIS)

    Wight, J.; Hong, R.M.; Phillips, J.C.; Lee, R.L.; Colleraine, A.P.; Kim, J.

    1989-12-01

    An automated personal computer based CAMAC data acquisition system is being implemented on the DIII-D neutral beamlines for certain diagnostics. The waterflow calorimetry (WFC) diagnostic is the first system to be upgraded. It includes data acquisition by a Macintosh II computer containing a National Instruments IEEE-488 card, and running their LabView software. Macintosh to CAMAC communications are carried out through an IEEE-488 crate controller. The Doppler shift spectroscopy, residual gas analysis, and armor tile infrared image diagnostics will be modified in similar ways. To reduce the demand for Macintosh CPU time, the extensive serial high-way data activity is performed by means of a new Kinetic Systems 3982 List sequencing Crate Controller dedicated to these operations. A simple Local Area Network file server is used to store data from all diagnostics together, and in a format readable by a standard commercial database. This reduces the problem of redundant data storage and allows simpler inter-diagnostic analysis. 3 refs., 4 figs

  18. Vacuum system design and tritium inventory for the TFTR charge exchange diagnostic

    International Nuclear Information System (INIS)

    Medley, S.S.

    1979-05-01

    The charge exchange diagnostic for the TFTR is comprised of two analyzer systems which contain a total of twenty independent mass/energy analyzers and one diagnostic neutral beam tentatively rated at 80 keV, 15 A. The associated vacuum systems were analyzed using the Vacuum System Transient Simulator (VSTS) computer program which models the transient transport of multi-gas species through complex networks of ducts, valves, traps, vacuum pumps, and other related vacuum system components. In addition to providing improved design performance at reduced cost, the analysis yields estimates for the exchange of tritium from the torus to the diagnostic components and of the diagnostic working gases to the torus

  19. Systems Bioinformatics: increasing precision of computational diagnostics and therapeutics through network-based approaches.

    Science.gov (United States)

    Oulas, Anastasis; Minadakis, George; Zachariou, Margarita; Sokratous, Kleitos; Bourdakou, Marilena M; Spyrou, George M

    2017-11-27

    Systems Bioinformatics is a relatively new approach, which lies in the intersection of systems biology and classical bioinformatics. It focuses on integrating information across different levels using a bottom-up approach as in systems biology with a data-driven top-down approach as in bioinformatics. The advent of omics technologies has provided the stepping-stone for the emergence of Systems Bioinformatics. These technologies provide a spectrum of information ranging from genomics, transcriptomics and proteomics to epigenomics, pharmacogenomics, metagenomics and metabolomics. Systems Bioinformatics is the framework in which systems approaches are applied to such data, setting the level of resolution as well as the boundary of the system of interest and studying the emerging properties of the system as a whole rather than the sum of the properties derived from the system's individual components. A key approach in Systems Bioinformatics is the construction of multiple networks representing each level of the omics spectrum and their integration in a layered network that exchanges information within and between layers. Here, we provide evidence on how Systems Bioinformatics enhances computational therapeutics and diagnostics, hence paving the way to precision medicine. The aim of this review is to familiarize the reader with the emerging field of Systems Bioinformatics and to provide a comprehensive overview of its current state-of-the-art methods and technologies. Moreover, we provide examples of success stories and case studies that utilize such methods and tools to significantly advance research in the fields of systems biology and systems medicine. © The Author 2017. Published by Oxford University Press.

  20. Computer-assisted initial diagnosis of rare diseases

    Directory of Open Access Journals (Sweden)

    Rui Alves

    2016-07-01

    Full Text Available Introduction. Most documented rare diseases have genetic origin. Because of their low individual frequency, an initial diagnosis based on phenotypic symptoms is not always easy, as practitioners might never have been exposed to patients suffering from the relevant disease. It is thus important to develop tools that facilitate symptom-based initial diagnosis of rare diseases by clinicians. In this work we aimed at developing a computational approach to aid in that initial diagnosis. We also aimed at implementing this approach in a user friendly web prototype. We call this tool Rare Disease Discovery. Finally, we also aimed at testing the performance of the prototype. Methods. Rare Disease Discovery uses the publicly available ORPHANET data set of association between rare diseases and their symptoms to automatically predict the most likely rare diseases based on a patient’s symptoms. We apply the method to retrospectively diagnose a cohort of 187 rare disease patients with confirmed diagnosis. Subsequently we test the precision, sensitivity, and global performance of the system under different scenarios by running large scale Monte Carlo simulations. All settings account for situations where absent and/or unrelated symptoms are considered in the diagnosis. Results. We find that this expert system has high diagnostic precision (≥80% and sensitivity (≥99%, and is robust to both absent and unrelated symptoms. Discussion. The Rare Disease Discovery prediction engine appears to provide a fast and robust method for initial assisted differential diagnosis of rare diseases. We coupled this engine with a user-friendly web interface and it can be freely accessed at http://disease-discovery.udl.cat/. The code and most current database for the whole project can be downloaded from https://github.com/Wrrzag/DiseaseDiscovery/tree/no_classifiers.

  1. Improved computer-assisted nuclear imaging in renovascular hypertension

    International Nuclear Information System (INIS)

    Gross, M.L.; Nally, J.V.; Potvini, W.J.; Clarke, H.S. Jr.; Higgins, J.T.; Windham, J.P.

    1985-01-01

    A computer-assisted program with digital background subtraction has been developed to analyze the initial 90 second Tc-99m DTPA renal flow scans in an attempt to quantitate the early isotope delivery to and uptake by the kidney. This study was designed to compare the computer-assisted 90 second DTPA scan with the conventional 30 minute I-131 Hippuran scan. Six patients with angiographically-proven unilateral renal artery stenosis were studied. The time activity curves for both studies were derived from regions of interest selected from the computer acquired dynamic images. The following parameters were used to assess renal blood flow: differential maximum activity, minimum/maximum activity ratio, and peak width. The computer-assisted DTPA study accurately predicted (6/6) the stenosed side documented angiographically, whereas the conventional Hippuran scan was clearly predictive in only 2/6. In selected cases successfully corrected surgically, the DTPA study proved superior in assessing the degree of patency of the graft. The best discriminatory factors when compared to a template synthesized from curves obtained from normal subjects were differential maximum activity and peak width. The authors conclude that: 1) the computer-assisted 90 second DTPA renal blood flow scan was superior to the conventional I-131 Hippuran scan in demonstrating unilateral reno-vascular disease; 2) the DTPA study was highly predictive of the angiographic findings; and 3) this non-invasive study should prove useful in the diagnosis and serial evaluation following surgery and/or angioplasty for renal artery stenosis

  2. Computer-Assisted Evaluation of Videokymographic Data

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Sedlář, Jiří; Zita, A.; Švec, J. G.; Zitová, Barbara; Flusser, Jan; Hauzar, D.

    2013-01-01

    Roč. 1, č. 1 (2013), s. 49-49 ISSN 1805-8698. [EFMI STC Prague Data and Knowledge for Medical Decision Support. 17.04.2013-19.04.2013, Praha] Institutional support: RVO:67985556 Keywords : videokymography * image process ing * computerassisted evaluation Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2013/ZOI/novozamsky-computer-assisted evaluation of videokymographic data.pdf

  3. Improving diagnostic accuracy using agent-based distributed data mining system.

    Science.gov (United States)

    Sridhar, S

    2013-09-01

    The use of data mining techniques to improve the diagnostic system accuracy is investigated in this paper. The data mining algorithms aim to discover patterns and extract useful knowledge from facts recorded in databases. Generally, the expert systems are constructed for automating diagnostic procedures. The learning component uses the data mining algorithms to extract the expert system rules from the database automatically. Learning algorithms can assist the clinicians in extracting knowledge automatically. As the number and variety of data sources is dramatically increasing, another way to acquire knowledge from databases is to apply various data mining algorithms that extract knowledge from data. As data sets are inherently distributed, the distributed system uses agents to transport the trained classifiers and uses meta learning to combine the knowledge. Commonsense reasoning is also used in association with distributed data mining to obtain better results. Combining human expert knowledge and data mining knowledge improves the performance of the diagnostic system. This work suggests a framework of combining the human knowledge and knowledge gained by better data mining algorithms on a renal and gallstone data set.

  4. Reliability analysis framework for computer-assisted medical decision systems

    International Nuclear Information System (INIS)

    Habas, Piotr A.; Zurada, Jacek M.; Elmaghraby, Adel S.; Tourassi, Georgia D.

    2007-01-01

    We present a technique that enhances computer-assisted decision (CAD) systems with the ability to assess the reliability of each individual decision they make. Reliability assessment is achieved by measuring the accuracy of a CAD system with known cases similar to the one in question. The proposed technique analyzes the feature space neighborhood of the query case to dynamically select an input-dependent set of known cases relevant to the query. This set is used to assess the local (query-specific) accuracy of the CAD system. The estimated local accuracy is utilized as a reliability measure of the CAD response to the query case. The underlying hypothesis of the study is that CAD decisions with higher reliability are more accurate. The above hypothesis was tested using a mammographic database of 1337 regions of interest (ROIs) with biopsy-proven ground truth (681 with masses, 656 with normal parenchyma). Three types of decision models, (i) a back-propagation neural network (BPNN), (ii) a generalized regression neural network (GRNN), and (iii) a support vector machine (SVM), were developed to detect masses based on eight morphological features automatically extracted from each ROI. The performance of all decision models was evaluated using the Receiver Operating Characteristic (ROC) analysis. The study showed that the proposed reliability measure is a strong predictor of the CAD system's case-specific accuracy. Specifically, the ROC area index for CAD predictions with high reliability was significantly better than for those with low reliability values. This result was consistent across all decision models investigated in the study. The proposed case-specific reliability analysis technique could be used to alert the CAD user when an opinion that is unlikely to be reliable is offered. The technique can be easily deployed in the clinical environment because it is applicable with a wide range of classifiers regardless of their structure and it requires neither additional

  5. CIT diagnostic computer interface studies

    International Nuclear Information System (INIS)

    Rauch, W.; Hayes, S.; Lowrance, J.; Oliaro, G.; Sauthoff, N.; Sichta, P.; Stark, W.

    1987-01-01

    This paper presents the on-going work performed in proposing instrumentation equipment and communications networks for the Diagnostic Data Acquisition and Diagnostic Instrumentation and Control System for the Compact Ignition Torus (CIT), which will begin operation in 1993. Consideration is given to the system criteria and requirements and their influence on the appropriate application of instrumentation and communication technologies to the system. This paper concentrates on the investigation of the bus communication technologies as they apply to the CIT data acquisition system. It compares CAMAC, VME, and FASTBUS as standards for data acquisition. The paper describes the connectivity between VAX equipment and CAMAC and VME instrumentation systems. Instrumentation and communication functionality and performance levels are presented as factors important to the overall data acquisition system performance

  6. Development of brake assist system. Summary of hydraulic brake assist system; Brake assist system no kaihatsu. Ekiatsushiki brake assist system no gaiyo

    Energy Technology Data Exchange (ETDEWEB)

    Hara, M; Ota, M; Shimizu, S [Toyota, Motor Corp., Aichi (Japan)

    1997-10-01

    We have already developed vacuum-booster-type Brake Assist System that supplies additional braking power when panic braking is recognized. We are convinced that the expansion of Brake Assist System will become more important issue in the future. Therefore we have developed hydraulic Brake Assist System with increasing its controllability and reducing its discomfort. This system have a brake pressure sensor to detect emergency braking operation and an antilock device to supply additional braking power. 8 refs., 11 figs.

  7. TMX-U computer system in evolution

    International Nuclear Information System (INIS)

    Casper, T.A.; Bell, H.; Brown, M.; Gorvad, M.; Jenkins, S.; Meyer, W.; Moller, J.; Perkins, D.

    1986-01-01

    Over the past three years, the total TMX-U diagnsotic data base has grown to exceed 10 megabytes from over 1300 channels; roughly triple the originally designed size. This acquisition and processing load has resulted in an experiment repetition rate exceeding 10 minutes per shot using the five original Hewlett-Packard HP-1000 computers with their shared disks. Our new diagnostics tend to be multichannel instruments, which, in our environment, can be more easily managed using local computers. For this purpose, we are using HP series 9000 computers for instrument control, data acquisition, and analysis. Fourteen such systems are operational with processed format output exchanged via a shared resource manager. We are presently implementing the necessary hardware and software changes to create a local area network allowing us to combine the data from these systems with our main data archive. The expansion of our diagnostic system using the paralled acquisition and processing concept allows us to increase our data base with a minimum of impact on the experimental repetition rate

  8. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  9. Local area network for the plasma diagnostics system of MFTF-B

    International Nuclear Information System (INIS)

    Lau, N.H.; Minor, E.G.

    1983-01-01

    The MFTF-B Plasma Diagnostics System will be implemented in stages, beginning with a start-up set of diagnostics and evolving toward a basic set. The start-up set contains 12 diagnostics which will acquire a total of about 800 Kbytes of data per machine pulse; the basic set contains 23 diagnostics which will acquire a total of about 8 Mbytes of data per pulse. Each diagnostic is controlled by a Foundation System consisting of a DEC LSI-11/23 microcomputer connected to CAMAC via a 5 Mbits/second serial fiber-optic link and connected to a supervisory computer (Perkin-Elmer 3250) via a 9600 baud RS232 link. The Foundation System is a building block used throughout MFTF-B for control and status monitoring. However, its 9600 baud link to the supervisor presents a bottleneck for the large data transfers required by diagnostics. To overcome this bottleneck the diagnostics Foundation Systems will be connected together with an additional LSI-11/23 called the master to form a Local Area Network (LAN) for data acquisition

  10. Interactive house investigation and radon diagnostics computer program

    International Nuclear Information System (INIS)

    Gillette, L.M.

    1990-01-01

    This paper reports on the interactive computer program called Dungeons and Radon which was developed as part of the Environmental Protection Agency's (EPA's) Radon Contractor Proficiency (RCP) Program's Radon Technology for Mitigators (RTM) course which is currently being offered in the Regional Radon Training Centers (RRTCs). The program was designed by Terry Brennan to be used in training radon mitigation contractors. The Macintosh based program consists of a series of animated, sound and voice enhanced house scenes. The participants choose where and what to investigate and where to perform diagnostic tests in order to gather enough information to design a successful mitigation system

  11. OpenID connect as a security service in Cloud-based diagnostic imaging systems

    Science.gov (United States)

    Ma, Weina; Sartipi, Kamran; Sharghi, Hassan; Koff, David; Bak, Peter

    2015-03-01

    The evolution of cloud computing is driving the next generation of diagnostic imaging (DI) systems. Cloud-based DI systems are able to deliver better services to patients without constraining to their own physical facilities. However, privacy and security concerns have been consistently regarded as the major obstacle for adoption of cloud computing by healthcare domains. Furthermore, traditional computing models and interfaces employed by DI systems are not ready for accessing diagnostic images through mobile devices. RESTful is an ideal technology for provisioning both mobile services and cloud computing. OpenID Connect, combining OpenID and OAuth together, is an emerging REST-based federated identity solution. It is one of the most perspective open standards to potentially become the de-facto standard for securing cloud computing and mobile applications, which has ever been regarded as "Kerberos of Cloud". We introduce OpenID Connect as an identity and authentication service in cloud-based DI systems and propose enhancements that allow for incorporating this technology within distributed enterprise environment. The objective of this study is to offer solutions for secure radiology image sharing among DI-r (Diagnostic Imaging Repository) and heterogeneous PACS (Picture Archiving and Communication Systems) as well as mobile clients in the cloud ecosystem. Through using OpenID Connect as an open-source identity and authentication service, deploying DI-r and PACS to private or community clouds should obtain equivalent security level to traditional computing model.

  12. Expert systems for plant operations training and assistance

    International Nuclear Information System (INIS)

    Pack, R.W.; Lazar, P.M.; Schmidt, R.V.; Gaddy, C.D.

    1988-01-01

    The project described in this paper explored the use of expert systems for plant operations training and assistance. Three computer technologies were reviewed: computer-aided instruction, expert systems, and expert training systems (ETS). The technology of CAI has been developed since the early 1960s, and a wide range of applications are available commercially today. Expert systems have been developed primarily as job performance aids, and the number of commercial applications is increasing. A fully developed ETS has models of the trainer and trainee, in addition to a knowledge base

  13. EUROPattern Suite technology for computer-aided immunofluorescence microscopy in autoantibody diagnostics.

    Science.gov (United States)

    Krause, C; Ens, K; Fechner, K; Voigt, J; Fraune, J; Rohwäder, E; Hahn, M; Danckwardt, M; Feirer, C; Barth, E; Martinetz, T; Stöcker, W

    2015-04-01

    Antinuclear autoantibodies (ANA) are highly informative biomarkers in autoimmune diagnostics. The increasing demand for effective test systems, however, has led to the development of a confusingly large variety of different platforms. One of them, the indirect immunofluorescence (IIF), is regarded as the common gold standard for ANA screening, as described in a position statement by the American College of Rheumatology in 2009. Technological solutions have been developed aimed at standardization and automation of IIF to overcome methodological limitations and subjective bias in IIF interpretation. In this review, we present the EUROPattern Suite, a system for computer-aided immunofluorescence microscopy (CAIFM) including automated acquisition of digital images and evaluation of IIF results. The system was originally designed for ANA diagnostics on human epithelial cells, but its applications have been extended with the latest system update version 1.5 to the analysis of antineutrophil cytoplasmic antibodies (ANCA) and anti-dsDNA antibodies. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Developing Computer Assisted Media of Pneumatic System Learning Oriented to Industrial Demands

    Directory of Open Access Journals (Sweden)

    Wahyu Dwi Kurniawan

    2017-04-01

    Full Text Available This study aimed to develop learning media of pneumatic systems based on computer-assisted learning as an effort to improve the competence of students at the Department of Mechanical Engineering, Faculty of Engineering UNESA. The development method referred to the 4D model design of Thiagarajan comprising the steps of: define, design, develop, and desseminate. The results showed that the expert validation average score included in both categories was 3.54, indicating the learning application acceptable. A limited test showed effective results, namely: (a Analysis of the data included in the category of learning was good (3.64, indicated by students’ enthusiasm in the learning process; (b Teaching learning activities were categorized as good, the students actively involved in learning, and the most dominant activity was doing tasks while discussing; (c Learning objectives were both achieved individually and classically; (d The students showed a positive response expressed by the students’ interest, excitement, and motivation to follow the learning process.

  15. Expert system for nuclear power plant feedwater system diagnosis

    International Nuclear Information System (INIS)

    Meguro, R.; Kinoshita, Y.; Sato, T.; Yokota, Y.; Yokota, M.

    1987-01-01

    The Expert System for Nuclear Power Plant Feedwater System Diagnosis has been developed to assist maintenance engineers in nuclear power plants. This system adopts the latest process computer TOSBAC G8050 and the expert system developing tool TDES2, and has a large scale knowledge base which consists of the expert knowledge and experience of engineers in many fields. The man-machine system, which has been developed exclusively for diagnosis, improves the man-machine interface and realizes the graphic displays of diagnostic process and path, stores diagnostic results and searches past reference

  16. Computational Diagnostic: A Novel Approach to View Medical Data.

    Energy Technology Data Exchange (ETDEWEB)

    Mane, K. K. (Ketan Kirtiraj); Börner, K. (Katy)

    2007-01-01

    A transition from traditional paper-based medical records to electronic health record is largely underway. The use of electronic records offers tremendous potential to personalize patient diagnosis and treatment. In this paper, we discuss a computational diagnostic tool that uses digital medical records to help doctors gain better insight about a patient's medical condition. The paper details different interactive features of the tool which offer potential to practice evidence-based medicine and advance patient diagnosis practices. The healthcare industry is a constantly evolving domain. Research from this domain is often translated into better understanding of different medical conditions. This new knowledge often contributes towards improved diagnosis and treatment solutions for patients. But the healthcare industry lags behind to seek immediate benefits of the new knowledge as it still adheres to the traditional paper-based approach to keep track of medical records. However recently we notice a drive that promotes a transition towards electronic health record (EHR). An EHR stores patient medical records in digital format and offers potential to replace the paper health records. Earlier attempts of an EHR replicated the paper layout on the screen, representation of medical history of a patient in a graphical time-series format, interactive visualization with 2D/3D generated images from an imaging device. But an EHR can be much more than just an 'electronic view' of the paper record or a collection of images from an imaging device. In this paper, we present an EHR called 'Computational Diagnostic Tool', that provides a novel computational approach to look at patient medical data. The developed EHR system is knowledge driven and acts as clinical decision support tool. The EHR tool provides two visual views of the medical data. Dynamic interaction with data is supported to help doctors practice evidence-based decisions and make judicious

  17. Diagnostic expert system in the PF LINAC

    International Nuclear Information System (INIS)

    Abe, Isamu; Nakahara, Kazuo; Kitamura, Masaharu.

    1992-01-01

    A prototype diagnostic expert system (ES) was developed for the Photon Factory 2.5-GeV electron/positron LINAC injector system. The ES has been on-lined with the conventional linac computer network for receiving real data. This project was undertaken in an attempt to reduce the linac operator's mental workload, diagnosis duties, and to explore Artificial Intelligence (AI) technologies. The outlook for ES and its problems, and what has been achieved are outlined in this presentation. (author)

  18. Promoting Intrinsic and Extrinsic Motivation among Chemistry Students Using Computer-Assisted Instruction

    Science.gov (United States)

    Gambari, Isiaka A.; Gbodi, Bimpe E.; Olakanmi, Eyitao U.; Abalaka, Eneojo N.

    2016-01-01

    The role of computer-assisted instruction in promoting intrinsic and extrinsic motivation among Nigerian secondary school chemistry students was investigated in this study. The study employed two modes of computer-assisted instruction (computer simulation instruction and computer tutorial instructional packages) and two levels of gender (male and…

  19. Computer-assisted planning and dosimetry for radiation treatment of head and neck cancer in Cameroon

    International Nuclear Information System (INIS)

    Yomi, J.; Ngniah, A.; Kingue, S.; Muna, W.F.T.; Durosinmi-Etti, F.A.

    1995-01-01

    This evaluation was part of a multicenter, multinational study sponsored by the International Agency for Atomic Energy (Vienna) to investigate a simple, reliable computer-assisted planning and dosimetry system for radiation treatment of head and neck cancers in developing countries. Over a 13-month period (April 1992-April 1993), 120 patients with histologically-proven head or neck cancer were included in the evaluation. In each patient, planning and dosimetry were done both manually and using the computer-assisted system. The manual and computerized systems were compared on the basis of accuracy of determination of the outer contour, target volume, and critical organs; volume inequality resolution; structure heterogeneity correction; selection of the number, angle, and size of beams; treatment time calculation; availability of dosimetry predictions; and duration and cost of the procedure. Results demonstrated that the computer-assisted procedure was superior over the manual procedure, despite less than optimal software. The accuracy provided by the completely computerized procedure is indispensable for Level II radiation therapy, which is particularly useful in tumors of the sensitive, complex structures in the head and neck. (authors). 7 refs., 3 tabs

  20. The Effects of Self-Regulatory Learning through Computer-Assisted Intelligent Tutoring System on the Improvement of EFL Learners' Speaking Ability

    Science.gov (United States)

    Mohammadzadeh, Ahmad; Sarkhosh, Mehdi

    2018-01-01

    The current study attempted to investigate the effects of self-regulatory learning through computer-assisted intelligent tutoring system on the improvement of speaking ability. The participants of the study, who spoke Azeri Turkish as their mother tongue, were students of Applied Linguistics at BA level at Pars Abad's Azad University, Ardebil,…

  1. Using a Touch-Based, Computer-Assisted Learning System to Promote Literacy and Math Skills for Low-Income Preschoolers

    OpenAIRE

    Mark H McManis; Lilla D McManis

    2016-01-01

    The use of touch-based technologies by young children to improve academic skills has seen growth outpacing empirical evidence of its effectiveness. Due to the educational challenges low-income children face, the stakes for providing instructional technology with demonstrated efficacy are high. The current work presents an empirical study of the use of a touch-based, computer-assisted learning system by low-income preschoolers. A description of the system’s design is provided with attention to...

  2. Maxillary arch rehabilitation using implant-supported computer-assisted design-computer-assisted manufacturing-milled titanium framework

    Directory of Open Access Journals (Sweden)

    Tulika S Khanna

    2017-01-01

    Full Text Available Esthetic and functional rehabilitation of completely edentulous maxillary arch with fixed implant supported prosthesis is a challenging task. Newer technologies such as computer assisted design computer assisted manufacturing (CAD CAM and cone beam conventional tomography play an important role in achieving predictable results. Full mouth porcelain fused to metal (PFM individual crowns on CAD CAM milled titanium framework provides positive esthetic and functional outcome. This is a case report of rehabilitation of partially edentulous maxillary arch patient. Staged rehabilitation of this patient was planned. In the first stage, root canal treatment of key abutment teeth was done, nonsalvageable teeth were removed, and immediate interim overdenture was provided. In the second stage, five Nobel Biocare dental implants were placed. After integration impressions were made, CAD CAM milled titanium bar was fabricated. Individual PFM crowns were made and cemented. This method gives better esthetic compared to acrylic fused to metal hybrid prosthesis with the advantage of retrievability just like screw retained prosthesis. Hence, this technique is good for rehabilitation of patients with high esthetic demands.

  3. Computer-aided diagnostic system for detection of Hashimoto thyroiditis on ultrasound images from a Polish population.

    Science.gov (United States)

    Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S

    2014-02-01

    Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.

  4. Computer-aided system design

    Science.gov (United States)

    Walker, Carrie K.

    1991-01-01

    A technique has been developed for combining features of a systems architecture design and assessment tool and a software development tool. This technique reduces simulation development time and expands simulation detail. The Architecture Design and Assessment System (ADAS), developed at the Research Triangle Institute, is a set of computer-assisted engineering tools for the design and analysis of computer systems. The ADAS system is based on directed graph concepts and supports the synthesis and analysis of software algorithms mapped to candidate hardware implementations. Greater simulation detail is provided by the ADAS functional simulator. With the functional simulator, programs written in either Ada or C can be used to provide a detailed description of graph nodes. A Computer-Aided Software Engineering tool developed at the Charles Stark Draper Laboratory (CSDL CASE) automatically generates Ada or C code from engineering block diagram specifications designed with an interactive graphical interface. A technique to use the tools together has been developed, which further automates the design process.

  5. HINT for Squint: A Computer Reliant Diagnostic Aid for Strabismus

    OpenAIRE

    Gieszl, Louis R.; Morris, Jacqueline; Guyton, David L.

    1983-01-01

    This paper provides an outline of methods used for the implementation of a computer reliant diagnostic aid in the medical specialty of Ophthalmology. Some problems have been associated with many previous diagnostic models. A careful review indicates that the most serious problems were:

  6. Computational surgery and dual training computing, robotics and imaging

    CERN Document Server

    Bass, Barbara; Berceli, Scott; Collet, Christophe; Cerveri, Pietro

    2014-01-01

    This critical volume focuses on the use of medical imaging, medical robotics, simulation, and information technology in surgery. It offers a road map for computational surgery success,  discusses the computer-assisted management of disease and surgery, and provides a rational for image processing and diagnostic. This book also presents some advances on image-driven intervention and robotics, as well as evaluates models and simulations for a broad spectrum of cancers as well as cardiovascular, neurological, and bone diseases. Training and performance analysis in surgery assisted by robotic systems is also covered. This book also: ·         Provides a comprehensive overview of the use of computational surgery and disease management ·         Discusses the design and use of medical robotic tools for orthopedic surgery, endoscopic surgery, and prostate surgery ·         Provides practical examples and case studies in the areas of image processing, virtual surgery, and simulation traini...

  7. MFTF supervisory control and diagnostics system hardware

    International Nuclear Information System (INIS)

    Butner, D.N.

    1979-01-01

    The Supervisory Control and Diagnostics System (SCDS) for the Mirror Fusion Test Facility (MFTF) is a multiprocessor minicomputer system designed so that for most single-point failures, the hardware may be quickly reconfigured to provide continued operation of the experiment. The system is made up of nine Perkin-Elmer computers - a mixture of 8/32's and 7/32's. Each computer has ports on a shared memory system consisting of two independent shared memory modules. Each processor can signal other processors through hardware external to the shared memory. The system communicates with the Local Control and Instrumentation System, which consists of approximately 65 microprocessors. Each of the six system processors has facilities for communicating with a group of microprocessors; the groups consist of from four to 24 microprocessors. There are hardware switches so that if an SCDS processor communicating with a group of microprocessors fails, another SCDS processor takes over the communication

  8. The graphics-based human interface to the DISYS diagnostic/control guidance system at EBR-2

    International Nuclear Information System (INIS)

    Edwards, R.M.; Chavez, C.; Kamarthi, S.; Dharap, S.; Lindsay, R.W.; Staffon, J.

    1990-01-01

    An initial graphics based interface to the real-time DISYS diagnostic system has been developed using the multi-tasking capabilities of the UNIX operating system and X-Windows 11 Xlib graphics library. This system is interfaced to live plant data at the Experimental Breeder Reactor (EBR-2) for the Argon Cooling System of fuel handling operations and the steam plant. The interface includes an intelligent process schematic which highlights problematic components and sensors based on the results of the diagnostic computations. If further explanation of a faulted component is required, the user can call up a display of the diagnostic computations presented in a tree-like diagram. Numerical data on the process schematic and optional diagnostic tree are updated as new real-time data becomes available. The initial X-Windows 11 based interface will be further enhanced using VI Corporation DATAVIEWS graphical data base software. 5 refs., 6 figs

  9. Interactive Computer-Assisted Instruction in Acid-Base Physiology for Mobile Computer Platforms

    Science.gov (United States)

    Longmuir, Kenneth J.

    2014-01-01

    In this project, the traditional lecture hall presentation of acid-base physiology in the first-year medical school curriculum was replaced by interactive, computer-assisted instruction designed primarily for the iPad and other mobile computer platforms. Three learning modules were developed, each with ~20 screens of information, on the subjects…

  10. Computer assisted active learning system development for critical thinking in history of civilization

    Directory of Open Access Journals (Sweden)

    Adem Karahoca

    2010-03-01

    Full Text Available This study investigates a Computer Assisted Learning System (CALS according to the several factors that promote flow wherestudents are fully involved into the learning activities for history of civilization lessons. The designed CALS supported bymeta – cognitive (cognitive maps and multimedia tools (movies, flash cards and quiz applications that help students to reacha flow state in learning by actively by engaging students’ critical thinking and providing an environment for active participation.The research data was collected using focus group surveys from a randomly selected 54 students enrolled in history ofcivilization at Bahcesehir University in Istanbul, Turkey. Results showed that 53.7% of students can be in flow via implementedCALS. Also according to the results, the flow has significant predictors in the course enjoyment, perceived competence ofcourse, value–usefulness and the challenge–learning style match according to nature of course in such a CALS.

  11. Computer assisted procedure maintenance

    International Nuclear Information System (INIS)

    Bisio, R.; Hulsund, J. E.; Nilsen, S.

    2004-04-01

    The maintenance of operating procedures in a NPP is a tedious and complicated task. Through the whole life cycle of the procedures they will be dynamic, 'living' documents. Several aspects of the procedure must be considered in a revision process. Pertinent details and attributes of the procedure must be checked. An organizational structure must be created and responsibilities allotted for drafting, revising, reviewing and publishing procedures. Available powerful computer technology provides solutions within document management and computerisation of procedures. These solutions can also support the maintenance of procedures. Not all parts of the procedure life cycle are equally amenable to computerized support. This report looks at the procedure life cycle in todays NPPs and discusses the possibilities associated with introduction of computer technology to assist the maintenance of procedures. (Author)

  12. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  13. Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device.

    Science.gov (United States)

    Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W

    2013-01-01

    The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.

  14. The local area network for the plasma Diagnostics System of MFTF-B

    International Nuclear Information System (INIS)

    Lau, N.H.; Minor, E.G.

    1983-01-01

    The MFTF-B Plasma Diagnostics System will be implemented in stages, beginning with a start-up set of diagnostics and evolving toward a basic set. The start-up set contains 12 diagnostics which will acquire a total of about 800 Kbytes of data per machine pulse; the basic set contains 23 diagnostics which will acquire a total of about 8 Mbytes of data per pulse. Each diagnostic is controlled by a ''Foundation System'' consisting of a DEC LSI-11/23 microcomputer connected to CAMAC via a 5 Mbits/second serial fiber-optic link and connected to a supervisory computer (Perkin-Elmer 3250) via a 9600 baud RS232 link. The Foundation System is a building block used throughout MFTF-B for control and status monitoring. However, its 9600 baud link to the supervisor presents a bottleneck for the large data transfers required by diagnostics. To overcome this bottleneck the diagnostics Foundation Systems will be connected together with an additional LSI-11/23 called the ''master'' to form a Local Area Network (LAN) for data acquisition. The Diagnostics LAN has a ring architecture with token passing arbitration

  15. A Personal Computer as Diagnostic Aid for Strabismus

    OpenAIRE

    Albicki, A.; Cohen, G.H.; Metz, H.S.

    1984-01-01

    This paper describes a microcomputer aided strabismus diagnostic system STRABCON. Two goals were achieved: at any time during the diagnostic process a list of plausible disorders are produced, and an optimal procedure for arriving at a final diagnosis is determined. This publication deals primarily with a microcomputer implementation of the STRABCON diagnostic system.

  16. An Instructor's Diagnostic Aid for Feedback in Training.

    Science.gov (United States)

    Andrews, Dee H.; Uliano, Kevin C.

    1988-01-01

    Instructor's Diagnostic Aid for Feedback in Training (IDAFT) is a computer-assisted method based on error analysis, domains of learning, and events of instruction. Its use with Navy team instructors is currently being explored. (JOW)

  17. Design of Intelligent Robot as A Tool for Teaching Media Based on Computer Interactive Learning and Computer Assisted Learning to Improve the Skill of University Student

    Science.gov (United States)

    Zuhrie, M. S.; Basuki, I.; Asto B, I. G. P.; Anifah, L.

    2018-01-01

    The focus of the research is the teaching module which incorporates manufacturing, planning mechanical designing, controlling system through microprocessor technology and maneuverability of the robot. Computer interactive and computer-assisted learning is strategies that emphasize the use of computers and learning aids (computer assisted learning) in teaching and learning activity. This research applied the 4-D model research and development. The model is suggested by Thiagarajan, et.al (1974). 4-D Model consists of four stages: Define Stage, Design Stage, Develop Stage, and Disseminate Stage. This research was conducted by applying the research design development with an objective to produce a tool of learning in the form of intelligent robot modules and kit based on Computer Interactive Learning and Computer Assisted Learning. From the data of the Indonesia Robot Contest during the period of 2009-2015, it can be seen that the modules that have been developed confirm the fourth stage of the research methods of development; disseminate method. The modules which have been developed for students guide students to produce Intelligent Robot Tool for Teaching Based on Computer Interactive Learning and Computer Assisted Learning. Results of students’ responses also showed a positive feedback to relate to the module of robotics and computer-based interactive learning.

  18. Evaluation of the TSC Dolphin Computer Assisted Instructional System in the Chapter 1 Program of the District of Columbia Public Schools. Final Report 85-9.

    Science.gov (United States)

    Harris, Carolyn DeMeyer; And Others

    Dolphin is a computer-assisted instruction system used to teach and reinforce skills in reading, language arts, and mathematics. An evaluation of this system was conducted to provide information to TSC Division of Houghton Mifflin regarding its effectiveness and possible modifications to the system. The general design of the evaluation was to…

  19. Computer data-acquisition and control system for Thomson-scattering measurements

    International Nuclear Information System (INIS)

    Stewart, K.A.; Foskett, R.D.; Kindsfather, R.R.; Lazarus, E.A.; Thomas, C.E.

    1983-03-01

    The Thomson-Scattering Diagnostic System (SCATPAK II) used to measure the electron temperature and density in the Impurity Study Experiment is interfaced to a Perkin-Elmer 8/32 computer that operates under the OS/32 operating system. The calibration, alignment, and operation of this diagnostic are all under computer control. Data acquired from 106 photomultiplier tubes installed on 15 spectrometers are transmitted to the computer by eighteen 12-channel, analog-to-digital integrators along a CAMAC serial highway. With each laser pulse, 212 channels of data are acquired: 106 channels of signal plus background and 106 channels of background only. Extensive use of CAMAC instrumentation enables large amounts of data to be acquired and control processes to be performed in a time-dependent environment. The Thomson-scattering computer system currently operates in three modes: user interaction and control, data acquisition and transmission, and data analysis. This paper discusses the development and implementation of this system as well as data storage and retrieval

  20. Computer assisted functional analysis. Computer gestuetzte funktionelle Analyse

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, H A.E.; Roesler, H

    1982-01-01

    The latest developments in computer-assisted functional analysis (CFA) in nuclear medicine are presented in about 250 papers of the 19th international annual meeting of the Society of Nuclear Medicine (Bern, September 1981). Apart from the mathematical and instrumental aspects of CFA, computerized emission tomography is given particular attention. Advances in nuclear medical diagnosis in the fields of radiopharmaceuticals, cardiology, angiology, neurology, ophthalmology, pulmonology, gastroenterology, nephrology, endocrinology, oncology and osteology are discussed.

  1. Toward computer-assisted diagnosis and telemedicine in ophthalmology

    Czech Academy of Sciences Publication Activity Database

    Marrugo, A.; Millán, M. S.; Cristóbal, G.; Gabarda, S.; Šorel, Michal; Šroubek, Filip

    2012-01-01

    Roč. 2012, č. 6 (2012), s. 1-3 ISSN 1818-2259 R&D Projects: GA MŠk 1M0572 Institutional research plan: CEZ:AV0Z10750506 Institutional support: RVO:67985556 Keywords : computer-aided diagnosis * medical and retinal image * deconvolution * telemedicine Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2012/ZOI/sorel-toward computer-assisted diagnosis and telemedicine in ophthalmology.pdf

  2. Computer-aided diagnostic system of diffuse liver diseases using scintiscanning, 1. Application of linear discriminant function

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, T; Ogawa, F; Okabe, H; Murakami, K [Kyoto Prefectural Univ. of Medicine (Japan); Yoshida, S

    1976-07-01

    An approach to an automated diagnostic system for diffuse parenchymal diseases of the liver is made based on hepatic scintigraphy and an electronic computer. The findings of hepatic scintigram with /sup 198/Au-colloid were analysed for 7 items, various patterns of hepatic image on anterior view, various patterns of hepatic image on right lateral view, criteria for visualization of bone marrow on anterior view, criteria for visualization of bone marrow on right lateral view, criteria for visualization of spleen on anterior view, degree of splenomegaly, and value of effective hepatic blood flow (KL-value). Each item was subdivided into several categories. Multivariate discriminant analysis was used for differential diagnosis of liver diseases with a dummy variable, based on the 25 categories of the 7 item on 100 abnormal hepato-scintigrams confirmed histologically, and on 20 normal subjects. This study was 90.0% accurate in normal liver, 81.1% accurate in acute hepatitis, 71.1% in inactive chronic hepatitis, 78.2% in active chronic hepatitis, 93.3% in Ko-type of liver cirrhosis, and 77.8% in the Otu-type of liver cirrhosis. The final diagnostic accuracy was 81.7% in all cases for training group. The accuracy of hepatic scintigraphy was 13% and 19% higher than that of laboratory findings in differentiating two groups of liver cirrhosis and two groups of chronic hepatitis respectively. To obtain maximum diagnostic information for discriminating among etiologies, ranges of discriminant function coefficients in these items were compared with in each group of liver diseases. The most useful diagnostic finding were the configurations of the hepatic images on the anterior and the right lateral views. Visualization of the spleen and the degree of splenomegaly were also useful for differentiation in each group of chronic hepatitis and liver cirrhosis.

  3. Development of JT-60 diagnostics system

    International Nuclear Information System (INIS)

    Suzuki, Yasuo

    1988-01-01

    The various kinds of plasma diagnostics have been developed and utilized in the JT-60 experiments. The features of JT-60 diagnostics system and the historical proceeding of the development are described in this paper. Taking account of the design consideration, JT-60 diagnostics system is sorted out into eight groups, which include six diagnostics systems, the data processing system and diagnostics supporting system. The all devices in the JT-60 diagnostics system were instrumented on schedule in the end of the fiscal year of 1985 and have contributed to JT-60 experiments. (author)

  4. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    Science.gov (United States)

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  5. Computer Assisted Programmed Instruction and Cognitive ...

    African Journals Online (AJOL)

    The study probes into the effect of Computer Assisted Instruction and Cognitive preference style on achievement of secondary school Physics Students in Ogun State of Nigeria. The population of the study comprises the SS II students in Abeokuta Educational Zone. 186 students sample were drawn from the population for ...

  6. Theorema 2.0: Computer-Assisted Natural-Style Mathematics

    Directory of Open Access Journals (Sweden)

    Bruno Buchberger

    2016-01-01

    Full Text Available The Theorema project aims at the development of a computer assistant for the working mathematician. Support should be given throughout all phases of mathematical activity, from introducing new mathematical concepts by definitions or axioms, through first (computational experiments, the formulation of theorems, their justification by an exact proof, the application of a theorem as an algorithm, until to the dissemination of the results in form of a mathematical publication, the build up of bigger libraries of certified mathematical content and the like. This ambitious project is exactly along the lines of the QED manifesto issued in 1994 (see e.g. http://www.cs.ru.nl/~freek/qed/qed.html and it was initiated in the mid-1990s by Bruno Buchberger. The Theorema system is a computer implementation of the ideas behind the Theorema project. One focus lies on the natural style of system input (in form of definitions, theorems, algorithms, etc., system output (mainly in form of mathematical proofs and user interaction. Another focus is theory exploration, i.e. the development of large consistent mathematical theories in a formal frame, in contrast to just proving single isolated theorems. When using the Theorema system, a user should not have to follow a certain style of mathematics enforced by the system (e.g. basing all of mathematics on set theory or certain variants of type theory, rather should the system support the user in her preferred flavour of doing math. The new implementation of the system, which we refer to as Theorema 2.0, is open-source and available through GitHub.

  7. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  8. Axial diagnostic system of finished rods BWR type

    International Nuclear Information System (INIS)

    Rivero G, T.; Rojas C, E.L.

    1996-01-01

    This system is employed as a final non destructive diagnostic system to verify the adequate distribution of the different enrichment through the can of nuclear fuel. The system is framed of traction mechanisms, a personal computer, a counting card and another card for the pass motor control, the nuclear electronics and the control program. The performance is based on the gamma radiation counting of the natural decay of uranium 235, this radiation is processed by the nuclear instrumentation for delivering a pulse by each gamma detected. (Author)

  9. Development and design of a computer-assisted information management system for radiation safety management at the University of Washington

    International Nuclear Information System (INIS)

    Riches, C.G.; Riordan, F.J.; Robb, D.; Grieb, C.; Pence, G.; O'Brien, M.J.

    1984-01-01

    The Radiation Safety Office (RSO) at the University of Washington (UW) found that it needed a computerized information system to help manage the campus radiation safety program and to help provide the records necessary to show compliance with regulations and license requirements. The John L. Locke Computer Center at the UW had just developed the GLAMOR system to aid information entry and query for their computer when the RSO turned to them for assistance. The module that was developed provided a mechanism for controlling and monitoring radioactive materials on campus. This became one part of a multi-faceted system that registers users, employees, sealed sources and radiation-producing machines. The system is designed to be interactive, for immediate information recall, and powerful enough to provide routine and special reports on compliance status. The RSO information system is designed to be flexible and can easily incorporate additional features. Some future features include an interactive SNM control program, an interface to the information system currently being developed for the occupational safety and health program and an interface to the database provided by the commercial film badge service used by the University. Development of this program lead the RSO to appreciate the usefulness of having health physics professionals on the staff who were also knowledgeable about computers and who could develop programs and reports necessary to their activities

  10. Development and testing of a diagnostic system for intelligen distributed control at EBR-2

    International Nuclear Information System (INIS)

    Edwards, R.M.; Ruhl, D.W.; Klevans, E.H.; Robinson, G.E.

    1990-01-01

    A diagnostic system is under development for demonstration of Intelligent Distributed Control at the Experimental Breeder Reactor (EBR--II). In the first phase of the project a diagnostic system is being developed for the EBR-II steam plant based on the DISYS expert systems approach. Current testing uses recorded plant data and data from simulated plant faults. The dynamical simulation of the EBR-II steam plant uses the Babcock and Wilcox (B ampersand W) Modular Modeling System (MMS). At EBR-II the diagnostic system operates in the UNIX workstation and receives live plant data from the plant Data Acquisition System (DAS). Future work will seek implementation of the steam plant diagnostic in a distributed manner using UNIX based computers and Bailey microprocessor-based control system. 10 refs., 6 figs

  11. Visual assistance system for cyclotron operation

    International Nuclear Information System (INIS)

    Okamura, Tetsuya; Tachikawa, Toshiki; Murakami, Tohru.

    1994-01-01

    A computer-based operation system for a cyclotron which assists operators has been developed. It is the operation assistance system depending on visual sense to indicate beam parameters to operators. First, the mental model of operators at the time of beam adjustment was analyzed, and it was presumed to be composed of five partial mental models, that is, beam behavior model, feasible setting region model, parameter sensitivity model, parameter interrelation model and status map model. Next, three visual interfaces were developed. Beam trajectory is rapidly calculated and graphically displayed whenever operators change parameters. Feasible setting regions (FSR) for parameters that satisfy the beam acceptance criteria of a cyclotron are indicated. The distribution of beam current values which are the quantity for evaluating adjustment is indicated as search history. Finally, for evaluating the system effectiveness, the search time required to reach the optimum conditions was measured. In addition, the system usability was evaluated by written questionnaires. The result of experiment showed the reduction of search time by about 65%. The written questionnaires survey showed the operators highly evaluate system usability. (K.I.)

  12. The Evolution of Computer Based Learning Software Design: Computer Assisted Teaching Unit Experience.

    Science.gov (United States)

    Blandford, A. E.; Smith, P. R.

    1986-01-01

    Describes the style of design of computer simulations developed by Computer Assisted Teaching Unit at Queen Mary College with reference to user interface, input and initialization, input data vetting, effective display screen use, graphical results presentation, and need for hard copy. Procedures and problems relating to academic involvement are…

  13. Integrated Artificial Intelligence Approaches for Disease Diagnostics.

    Science.gov (United States)

    Vashistha, Rajat; Chhabra, Deepak; Shukla, Pratyoosh

    2018-06-01

    Mechanocomputational techniques in conjunction with artificial intelligence (AI) are revolutionizing the interpretations of the crucial information from the medical data and converting it into optimized and organized information for diagnostics. It is possible due to valuable perfection in artificial intelligence, computer aided diagnostics, virtual assistant, robotic surgery, augmented reality and genome editing (based on AI) technologies. Such techniques are serving as the products for diagnosing emerging microbial or non microbial diseases. This article represents a combinatory approach of using such approaches and providing therapeutic solutions towards utilizing these techniques in disease diagnostics.

  14. Innovative Partnerships Assist Community College Computing Programs.

    Science.gov (United States)

    O'Banion, Terry

    1987-01-01

    Relates efforts of major corporations in providing assistance to community college computing programs. Explains the goals of the League for Innovation in the Community College, a consortium of 19 community colleges, and cites examples of collaborative projects. (ML)

  15. The assisting system for uranium enrichment plant operation

    International Nuclear Information System (INIS)

    Nakazawa, Hiroaki; Yamamoto, Fumio

    1990-01-01

    We have been developing an operation assisting system, partially supported by AI system, for uranium enrichment plant. The AI system is a proto-type system aiming a final one which can be applied to any future large uranium enrichment plant and also not only to specific operational area but also to complex and multi-phenomenon operational area. An existing AI system, for example facility diagnostic system that utilizes the result of CCT analysis as knowledge base, has weakness in flexibility and potentiality. To build AI system, we have developed the most suitable knowledge representations using deep knowledge for each facility or operation of uranium enrichment plant. This paper describes our AI proto-type system adopting several knowledge representations that can represent an uranium enrichment plant's operation with deep knowledge. (author)

  16. LOFT advanced control room operator diagnostic and display system (ODDS)

    International Nuclear Information System (INIS)

    Larsen, D.G.; Robb, T.C.

    1980-01-01

    The Loss-of-Fluid Test (LOFT) Reactor Facility in Idaho includes a highly instrumented nuclear reactor operated by the Department of Energy for the purpose of establishing nuclear safety requirements. The results of the development and installation into LOFT of an Operator Diagnostic and Display System (ODDS) are presented. The ODDS is a computer-based graphics display system centered around a PRIME 550 computer with several RAMTEK color graphic display units located within the control room and available to the reactor operators. Use of computer-based color graphics to aid the reactor operator is discussed. A detailed hardware description of the LOFT data system and the ODDS is presented. Methods and problems of backfitting the ODDS equipment into the LOFT plant are discussed

  17. Accurate measurement of surface areas of anatomical structures by computer-assisted triangulation of computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Allardice, J.T.; Jacomb-Hood, J.; Abulafi, A.M.; Williams, N.S. (Royal London Hospital (United Kingdom)); Cookson, J.; Dykes, E.; Holman, J. (London Hospital Medical College (United Kingdom))

    1993-05-01

    There is a need for accurate surface area measurement of internal anatomical structures in order to define light dosimetry in adjunctive intraoperative photodynamic therapy (AIOPDT). The authors investigated whether computer-assisted triangulation of serial sections generated by computed tomography (CT) scanning can give an accurate assessment of the surface area of the walls of the true pelvis after anterior resection and before colorectal anastomosis. They show that the technique of paper density tessellation is an acceptable method of measuring the surface areas of phantom objects, with a maximum error of 0.5%, and is used as the gold standard. Computer-assisted triangulation of CT images of standard geometric objects and accurately-constructed pelvic phantoms gives a surface area assessment with a maximum error of 2.5% compared with the gold standard. The CT images of 20 patients' pelves have been analysed by computer-assisted triangulation and this shows the surface area of the walls varies from 143 cm[sup 2] to 392 cm[sup 2]. (Author).

  18. 77 FR 39498 - Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection...

    Science.gov (United States)

    2012-07-03

    ...] Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection Devices Applied... Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to... guidance, entitled ``Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device...

  19. Computer-Assisted Instruction and Continuing Motivation.

    Science.gov (United States)

    Mosley, Mary Lou; And Others

    Effects of two feedback conditions--comment and no comment--on the motivation of sixth grade students to continue with computer assisted instruction (CAI) were investigated, and results for boys and for girls were compared. Subjects were 62 students--29 boys and 33 girls--from a suburban elementary school who were randomly assigned to the comment…

  20. MIDAS, prototype Multivariate Interactive Digital Analysis System, Phase 1. Volume 2: Diagnostic system

    Science.gov (United States)

    Kriegler, F. J.; Christenson, D.; Gordon, M.; Kistler, R.; Lampert, S.; Marshall, R.; Mclaughlin, R.

    1974-01-01

    The MIDAS System is a third-generation, fast, multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from present and projected sensors. A principal objective of the MIDAS Program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughout. The hardware and software generated in Phase I of the over-all program are described. The system contains a mini-computer to control the various high-speed processing elements in the data path and a classifier which implements an all-digital prototype multivariate-Gaussian maximum likelihood decision algorithm operating 2 x 105 pixels/sec. Sufficient hardware was developed to perform signature extraction from computer-compatible tapes, compute classifier coefficients, control the classifier operation, and diagnose operation. Diagnostic programs used to test MIDAS' operations are presented.

  1. Balloon-assisted coiling through a 5-French system

    International Nuclear Information System (INIS)

    White, J. Bradley; Layton, Kennith F.; Kallmes, David F.; Cloft, Harry J.

    2007-01-01

    We present a catheter technique that utilizes a 5F system for the purpose of balloon-assisted coiling in the setting of intracranial aneurysms. A standard 5F short sheath is placed in the common femoral artery, and a 5F diagnostic catheter is placed through the sheath and used for selective vessel angiography. When endovascular intervention is pursued, the diagnostic catheter is placed in the appropriate vessel and systemic heparinization is ensured. Over an exchange length wire, the 5F vertebral catheter and 5F short sheath are exchanged for a 5F Shuttle (Cook) sheath. We then routinely place a 10, 14 or 18 microcatheter over an appropriately gauged microguidewire into the aneurysm. As needed, balloon catheters are then placed across the neck of the aneurysm for remodeling purposes. During the course of the procedure, control angiography is performed through the Shuttle sheath. Following the placement of coils, the microcatheter and balloon catheter are removed and a final biplane image is obtained via the 5F Shuttle sheath. This technique has been employed in 15 patients who required balloon-assisted coiling of an intracranial aneurysm. There were no technical difficulties or arterial access site complications from the procedures. Catheter mobility and torque were not affected, nor was the quality of our imaging. We conclude that this small-diameter system provides ample ''room'' for catheter placement and interventional treatment while reducing the known risks of postprocedural complications. Angiographic images remain excellent and are comparable to those obtained by larger catheters. (orig.)

  2. An Overview of Recent Developments in Cognitive Diagnostic Computer Adaptive Assessments

    Directory of Open Access Journals (Sweden)

    Alan Huebner

    2010-01-01

    Full Text Available Cognitive diagnostic modeling has become an exciting new field of psychometric research. These models aim to diagnose examinees' mastery status of a group of discretely defined skills, or attributes, thereby providing them with detailed information regarding their specific strengths and weaknesses. Combining cognitive diagnosis with computer adaptive assessments has emerged as an important part of this new field. This article aims to provide practitioners and researchers with an introduction to and overview of recent developments in cognitive diagnostic computer adaptive assessments.

  3. Conventional radiography and computed tomography of cardiac assist devices

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Stolzmann, Paul; Desbiolles, Lotus; Leschka, Sebastian; Frauenfelder, Thomas; Schertler, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wilhelm, Markus J.; Lachat, Mario [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland)

    2009-09-15

    Patients intended for circulatory support by cardiac assist devices (CAD) usually suffer from end-stage acute or chronic heart failure. Since the introduction of CAD in 1963 by DeBakey and coworkers, the systems have gone through a substantial evolution and have been increasingly used in the intervening decades. The spectrum of CAD includes a variety of systems serving to assist the systolic function of the left ventricle, the right ventricle, or both. Conventional radiography and multislice spiral computed tomography (CT) are the most commonly used radiological techniques for imaging patients with a CAD. CT is very useful for evaluating CAD systems by using both two- and three-dimensional reconstructions of the volumetric data sets. The two techniques together allow for the comprehensive assessment of patients with devices by imaging the in- and outflow cannulae, the anastomoses, the position of the pump, as well as associated complications. A close collaboration with cardiac surgeons with expertise in the field of circulatory support is deemed necessary for adequate image interpretation. This article describes the technical diversity of the currently available CAD systems. The imaging characteristics on conventional radiography and multislice spiral CT as well as the typical complications of their use are demonstrated. (orig.)

  4. MFTF-B plasma-diagnostic system

    International Nuclear Information System (INIS)

    Throop, A.L.; Goerz, D.A.; Thomas, S.R.

    1981-01-01

    This paper describes the current design status of the plasma diagnostic system for MFTF-B. In this paper we describe the system requirement changes which have occurred as a result of the funded rescoping of the original MFTF facility into MFTF-B. We outline the diagnostic instruments which are currently planned, and present an overview of the diagnostic system

  5. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Kiran, E-mail: kkpatel@ipr.res.in; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-11-15

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  6. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    International Nuclear Information System (INIS)

    Patel, Kiran; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-01-01

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  7. 75 FR 32519 - Miracor Diagnostics, Inc., Monaco Finance, Inc., MPEL Holdings Corp. (f/k/a Computer Transceiver...

    Science.gov (United States)

    2010-06-08

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] Miracor Diagnostics, Inc., Monaco Finance, Inc., MPEL Holdings Corp. (f/k/a Computer Transceiver Systems, Inc.), MR3 Systems, Inc., Mutual Risk... concerning the securities of Monaco Finance, Inc. because it has not filed any periodic reports since the...

  8. Computer-assisted navigational surgery enhances safety in dental implantology.

    Science.gov (United States)

    Ng, F C; Ho, K H; Wexler, A

    2005-06-01

    Dental implants are increasingly used to restore missing dentition. These titanium implants are surgically installed in the edentulous alveolar ridge and allowed to osteointegrate with the bone during the healing phase. After osseo-integration, the implant is loaded with a prosthesis to replace the missing tooth. Conventional implant treatment planning uses study models, wax-ups and panoramic x-rays to prefabricate surgical stent to guide the preparation of the implant site. The drilling into the alveolar ridge is invariably a "blind" procedure as the part of the drill in bone is not visible. Stereotactic systems were first introduced into neurosurgery in 1986. Since then, computer-assisted navigational technology has brought major advances to neuro-, midface and orthopaedic surgeries, and more recently, to implant placement. This paper illustrates the use of real-time computer-guided navigational technology in enhancing safety in implant surgical procedures. Real-time computer-guided navigational technology enhances accuracy and precision of the surgical procedure, minimises complications and facilitates surgery in challenging anatomical locations.

  9. Research on the Use of Computer-Assisted Instruction.

    Science.gov (United States)

    Craft, C. O.

    1982-01-01

    Reviews recent research studies related to computer assisted instruction (CAI). The studies concerned program effectiveness, teaching of psychomotor skills, tool availability, and factors affecting the adoption of CAI. (CT)

  10. L'Enseignement des langues assiste par ordinateur: nouvelle pedagogie? (Computer Assisted Language Instruction: New Pedagogy?).

    Science.gov (United States)

    Elkabas, Charles

    1989-01-01

    Recent second language instruction computer software focuses almost exclusively on the structures and forms of language, and on programed learning instead of developing communicative skills. Until artificial intelligence changes these old behavioristic principles, computer-assisted language instruction can only play a minor role in language…

  11. 43 Computer Assisted Programmed Instruction and Cognitive ...

    African Journals Online (AJOL)

    cce

    between Cognitive Preference Style and Computer Assisted Programmed ... teaching the subjects makes a wide range of students who have moderate numerical ability and ... on achievement of physics students, more so when such strategy has .... explaining prompting, thinking, discussing, clarifying concepts, asking ...

  12. Human – Computer Systems Interaction Backgrounds and Applications 2 Part 2

    CERN Document Server

    Kulikowski, Juliusz; Mroczek, Teresa

    2012-01-01

    This volume of the book contains a collection of chapters selected from the papers which originally (in shortened form) have been presented at the 3rd International Conference on Human-Systems Interaction held in Rzeszow, Poland, in 2010. The chapters are divided into five sections concerning: IV. Environment monitoring and robotic systems, V. Diagnostic systems, VI. Educational Systems, and VII. General Problems. The novel concepts and realizations of humanoid robots, talking robots and orthopedic surgical robots, as well as those of direct brain-computer interface  are examples of particularly interesting topics presented in Sec. VI. In Sec. V the problems of  skin cancer recognition, colonoscopy diagnosis, and brain strokes diagnosis as well as more general problems of ontology design for  medical diagnostic knowledge are presented. Example of an industrial diagnostic system and a concept of new algorithm for edges detection in computer-analyzed images  are also presented in this Section. Among the edu...

  13. Computer program for diagnostic X-ray exposure conversion

    International Nuclear Information System (INIS)

    Lewis, S.L.

    1984-01-01

    Presented is a computer program designed to convert any given set of diagnostic X-ray exposure factors sequentially into another, yielding either an equivalent photographic density or one increased or decreased by a specifiable proportion. In addition to containing the wherewithal with which to manipulate a set of exposure factors, the facility to print hard (paper) copy is included enabling the results to be pasted into a notebook and used at any time. This program was originally written as an investigative exercise into examining the potential use of computers for practical radiographic purposes as conventionally encountered. At the same time, its possible use as an educational tool was borne in mind. To these ends, the current version of this program may be used as a means whereby exposure factors used in a diagnostic department may be altered to suit a particular requirement or may be used in the school as a mathematical model to describe the behaviour of exposure factors under manipulation without patient exposure. (author)

  14. The use of computer-assisted interactive videodisc training in reactor operations at the Savannah River site

    International Nuclear Information System (INIS)

    Shiplett, D.W.

    1990-01-01

    This presentation discussed the use of computer aided training at Savannah River Site using a computer-assisted interactive videodisc system. This system was used in situations where there was a high frequency of training required, where there were a large number of people to be trained and where there was a rigid work schedule. The system was used to support classroom training to emphasize major points, display graphics of flowpaths, for simulations, and video of actual equipment

  15. Errors and Intelligence in Computer-Assisted Language Learning: Parsers and Pedagogues. Routledge Studies in Computer Assisted Language Learning

    Science.gov (United States)

    Heift, Trude; Schulze, Mathias

    2012-01-01

    This book provides the first comprehensive overview of theoretical issues, historical developments and current trends in ICALL (Intelligent Computer-Assisted Language Learning). It assumes a basic familiarity with Second Language Acquisition (SLA) theory and teaching, CALL and linguistics. It is of interest to upper undergraduate and/or graduate…

  16. Overview of the data acquisition and control system for plasma diagnostics on MFTF-B

    International Nuclear Information System (INIS)

    Wyman, R.H.; Deadrick, F.J.; Lau, N.H.; Nelson, B.C.; Preckshot, G.G.; Throop, A.L.

    1983-01-01

    For MFTF-B, the plasma diagnostics system is expected to grow from a collection of 12 types of diagnostic instruments, initially producing about 1 Megabyte of data per shot, to an expanded set of 22 diagnostics producing about 8 Megabytes of data per shot. To control these diagnostics and acquire and process the data, a system design has been developed which uses an architecture similar to the supervisory/local-control computer system which is used to control other MFTF-B subsystems. This paper presents an overview of the hardware and software that will control and acquire data from the plasma diagnostics system. Data flow paths from the instruments, through processing, and into final archived storage will be described. A discussion of anticipated data rates, including anticipated software overhead at various points of the system, is included, along with the identification of possible bottlenecks. A methodology for processing of the data is described, along with the approach to handle the planned growth in the diagnostic system. Motivations are presented for various design choices which have been made

  17. Computer aided design, analysis and experimental investigation of membrane assisted batch reaction-separation systems

    DEFF Research Database (Denmark)

    Mitkowski, Piotr Tomasz; Buchaly, Carsten; Kreis, Peter

    2009-01-01

    Membrane assisted batch reaction operation offers an interesting option for equilibrium limited reaction systems in chemical and biochemical manufacturing by selective removal of one of the products and thereby increasing the product yield. The design of such hybrid systems need to take into acco......Membrane assisted batch reaction operation offers an interesting option for equilibrium limited reaction systems in chemical and biochemical manufacturing by selective removal of one of the products and thereby increasing the product yield. The design of such hybrid systems need to take...... into account the performance of each constituent element and the optimisation of the design must take into consideration their interdependency. In this paper use of a membrane, to assist in the synthesis of propyl-propionate is investigated through the use of a hybrid process design framework, which consists...... and separation functionalities and to design/analyse the hybrid scheme. The generated hybrid scheme has been validated through experiments involving an esterification reaction....

  18. Accuracy of a computer-assisted planning and placement system for anatomical femoral tunnel positioning in anterior cruciate ligament reconstruction

    NARCIS (Netherlands)

    Luites, J.W.H.; Wymenga, A.B.; Blankevoort, L.; Eygendaal, D.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    Background Femoral tunnel positioning is a difficult, but important factor in successful anterior cruciate ligament (ACL) reconstruction. Computer navigation can improve the anatomical planning procedure besides the tunnel placement procedure. Methods The accuracy of the computer-assisted femoral

  19. An intelligent multi-media human-computer dialogue system

    Science.gov (United States)

    Neal, J. G.; Bettinger, K. E.; Byoun, J. S.; Dobes, Z.; Thielman, C. Y.

    1988-01-01

    Sophisticated computer systems are being developed to assist in the human decision-making process for very complex tasks performed under stressful conditions. The human-computer interface is a critical factor in these systems. The human-computer interface should be simple and natural to use, require a minimal learning period, assist the user in accomplishing his task(s) with a minimum of distraction, present output in a form that best conveys information to the user, and reduce cognitive load for the user. In pursuit of this ideal, the Intelligent Multi-Media Interfaces project is devoted to the development of interface technology that integrates speech, natural language text, graphics, and pointing gestures for human-computer dialogues. The objective of the project is to develop interface technology that uses the media/modalities intelligently in a flexible, context-sensitive, and highly integrated manner modelled after the manner in which humans converse in simultaneous coordinated multiple modalities. As part of the project, a knowledge-based interface system, called CUBRICON (CUBRC Intelligent CONversationalist) is being developed as a research prototype. The application domain being used to drive the research is that of military tactical air control.

  20. Computer assisted tutoring in radiology

    International Nuclear Information System (INIS)

    Jeffery, N.

    1997-02-01

    The computer-based tutoring of visual concepts such as radiological images is a largely unexplored area. A review of the literature highlights limited use of computers as a means of radiological education, with the majority of systems being little more than hypermedia prototypes, on-line teaching files, and passive CD-Roms. Very few of the systems discussed in the research literature draw on the work from cognitive science and educational psychology for tutoring visual concepts. This thesis details and evaluates a method for indexing and retrieving images from large image databases via a cognitively informed graphical representation of visual concepts. This representation is derived using Multiple Correspondence Analysis from a statistical analysis of features present in the images. It is intended that this representation be used to assist in the computer based teaching of any discipline that requires the tutoring of visual concepts. The domain used as a test bed for this research is Magnetic Resonance Imaging in neuroradiology. Tutoring the interpretation of MR scans of the head represents a real practical problem due to the inherent complexity of the brain and variations in tissue contrast within image sequence and disease/pathology. The literature of concept categorisation and representation is critically reviewed to inform the design of a graphical representation of a concept (a pathology in the application domain). A specification for the design of an explicit representation of visual concepts is drawn from this literature review, together with methods of tutoring based around this model. A methodology for producing this representation is described, and implemented in the development of an overview plot for the concept of a disease of the brain, with associated statistical measures derived and operationalised for typicality and similarity of cases within a disease. These measures are precursors to the development of computer based tutoring strategies for image

  1. Computer assisted tutoring in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Jeffery, N

    1997-02-01

    The computer-based tutoring of visual concepts such as radiological images is a largely unexplored area. A review of the literature highlights limited use of computers as a means of radiological education, with the majority of systems being little more than hypermedia prototypes, on-line teaching files, and passive CD-Roms. Very few of the systems discussed in the research literature draw on the work from cognitive science and educational psychology for tutoring visual concepts. This thesis details and evaluates a method for indexing and retrieving images from large image databases via a cognitively informed graphical representation of visual concepts. This representation is derived using Multiple Correspondence Analysis from a statistical analysis of features present in the images. It is intended that this representation be used to assist in the computer based teaching of any discipline that requires the tutoring of visual concepts. The domain used as a test bed for this research is Magnetic Resonance Imaging in neuroradiology. Tutoring the interpretation of MR scans of the head represents a real practical problem due to the inherent complexity of the brain and variations in tissue contrast within image sequence and disease/pathology. The literature of concept categorisation and representation is critically reviewed to inform the design of a graphical representation of a concept (a pathology in the application domain). A specification for the design of an explicit representation of visual concepts is drawn from this literature review, together with methods of tutoring based around this model. A methodology for producing this representation is described, and implemented in the development of an overview plot for the concept of a disease of the brain, with associated statistical measures derived and operationalised for typicality and similarity of cases within a disease. These measures are precursors to the development of computer based tutoring strategies for image

  2. deNIS IIplus - computer-assisted crisis management system

    International Nuclear Information System (INIS)

    Corr, B.

    2007-01-01

    The management of catastrophes, as natural disasters or manmade disasters, will only be effective and successful if all relevant information is available in time for decision-makers. During previous large-scale disasters it became evident that information needed for the disaster management was only partially available and that there were fundamental deficits in regard to the flow of information between federal states (''Laender'') as well as communication problems between disaster response teams in the effected regions. On this account in summer 2001 the Federal Ministry of the Interior has decided to develop the ''German Emergency Preparedness Information System (deNIS)''. The aim of the enhanced version deNIS II plus is to built up a network for the civil and disaster response and to assist as an information and communication system for decision-makers of the Federal Government and the Laender Governments to better co-ordination relief and rescue teams in the event of a natural disaster or technical accident. Correspondingly the primary task of deNIS is to support the decision-making of disaster management authorities. (orig.)

  3. Electrical probe diagnostic with fast data acquisition systems of the Novillo tokamak

    International Nuclear Information System (INIS)

    Lopez-Callejas, R.; Benitez-Read, J.S.; Longoria-Gandara, L.C.; Pacheco-Sotelo, J.O.; Valencia-Alvarado, R.; Tamayo, F.J.; Valdes, A.; Fernandez, M.C.; Serrano, F.

    2001-01-01

    This paper describes the electrical probe diagnostic system used to measure the relevant parameters of the plasma column generated in the Novillo tokamak, and an inexpensive and fast data acquisition system that consists of 16 independent channels, 8 bit resolution, sampling frequency of 500 kHz, and 8 kword memory per channel. A distributed, modular and transparent approach was used for designing the software-operated data acquisition, diagnostic, and capacitor banks triggering systems, satisfying the pulsed nature of the tokamak discharge. Through a personal computer, the experimental data are available to engineers and physicists in a centralized database

  4. Providing Assistive Technology Applications as a Service Through Cloud Computing.

    Science.gov (United States)

    Mulfari, Davide; Celesti, Antonio; Villari, Massimo; Puliafito, Antonio

    2015-01-01

    Users with disabilities interact with Personal Computers (PCs) using Assistive Technology (AT) software solutions. Such applications run on a PC that a person with a disability commonly uses. However the configuration of AT applications is not trivial at all, especially whenever the user needs to work on a PC that does not allow him/her to rely on his / her AT tools (e.g., at work, at university, in an Internet point). In this paper, we discuss how cloud computing provides a valid technological solution to enhance such a scenario.With the emergence of cloud computing, many applications are executed on top of virtual machines (VMs). Virtualization allows us to achieve a software implementation of a real computer able to execute a standard operating system and any kind of application. In this paper we propose to build personalized VMs running AT programs and settings. By using the remote desktop technology, our solution enables users to control their customized virtual desktop environment by means of an HTML5-based web interface running on any computer equipped with a browser, whenever they are.

  5. Listening Strategy Use and Influential Factors in Web-Based Computer Assisted Language Learning

    Science.gov (United States)

    Chen, L.; Zhang, R.; Liu, C.

    2014-01-01

    This study investigates second and foreign language (L2) learners' listening strategy use and factors that influence their strategy use in a Web-based computer assisted language learning (CALL) system. A strategy inventory, a factor questionnaire and a standardized listening test were used to collect data from a group of 82 Chinese students…

  6. Framework for computer-aided systems design

    International Nuclear Information System (INIS)

    Esselman, W.H.

    1992-01-01

    Advanced computer technology, analytical methods, graphics capabilities, and expert systems contribute to significant changes in the design process. Continued progress is expected. Achieving the ultimate benefits of these computer-based design tools depends on successful research and development on a number of key issues. A fundamental understanding of the design process is a prerequisite to developing these computer-based tools. In this paper a hierarchical systems design approach is described, and methods by which computers can assist the designer are examined. A framework is presented for developing computer-based design tools for power plant design. These tools include expert experience bases, tutorials, aids in decision making, and tools to develop the requirements, constraints, and interactions among subsystems and components. Early consideration of the functional tasks is encouraged. Methods of acquiring an expert's experience base is a fundamental research problem. Computer-based guidance should be provided in a manner that supports the creativity, heuristic approaches, decision making, and meticulousness of a good designer

  7. Diagnostic value of computer tomography in chronic pancreatitis

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Schrumpf, E.; Bergan, A.; Larsen, S.

    1981-01-01

    During a 3-year-period 39 patients with chronic pancreatitis were subjected to roentgen examinations and exocrine pancreatic function tests (EPFT). Computer tomography (CT) was carried out in 36 of these, and revealed pancreatic disease in 29, while characteristic findings of chronic pancreatitis were demonstrated in 24 patients. CT was particularly valuable in diagnosing intra- and extrapancreatic pseudocysts and pancreatic abscesses complicating chronic pancreatitis. At endoscopic retrograde pancreatography (ERP) pathologic alterations were demonstrated in 23 of 24 patients, and was diagnostic for chronic pancreatitis in 20 patients. The cannulation failed in 7 patients. The results indicate that ERP cannot be replaced by CT. ERP is still needed for detailed demonstration of the pancreatic duct system, especially preoperatively. Conventional films of the abdomen, EPFT and angiography were the least sensitive tests. (Auth.)

  8. Integration of autonomous systems for remote control of data acquisition and diagnostics in the TJ-II device

    International Nuclear Information System (INIS)

    Vega, J.; Mollinedo, A.; Lopez, A.; Pacios, L.; Dormido, S.

    1997-01-01

    The data acquisition system for TJ-II will consist of a central computer, containing the data base of the device, and a set of independent systems (personal computers, embedded ones, workstations, minicomputers, PLCs, and microprocessor systems among others), controlling data collection, and automated diagnostics. Each autonomous system can be used to isolate and manage specific problems in the most efficient manner. These problems are related to data acquisition, hard (μs endash ms) real time requirements, soft (ms endash s) real time requirements, remote control of diagnostics, etc. In the operation of TJ-II, the programming of systems will be carried out from the central computer. Coordination and synchronization will be performed by linking systems to local area networks. Several Ethernet segments and FDDI rings will be used for these purposes. Programmable logic controller devices (PLCs) used for diagnostic low level control will be linked among them through a fast serial link, the RS485 Profibus standard. One VME crate, running on the OS-9 real time operating system, will be assigned as a gateway, so as to connect the PLCs based systems with an Ethernet segment. copyright 1997 American Institute of Physics

  9. Mechanical Design Technology--Modified. (Computer Assisted Drafting, Computer Aided Design). Curriculum Grant 84/85.

    Science.gov (United States)

    Schoolcraft Coll., Livonia, MI.

    This document is a curriculum guide for a program in mechanical design technology (computer-assisted drafting and design developed at Schoolcraft College, Livonia, Michigan). The program helps students to acquire the skills of drafters and to interact with electronic equipment, with the option of becoming efficient in the computer-aided…

  10. [APPLICATION OF COMPUTER-ASSISTED TECHNOLOGY IN ANALYSIS OF REVISION REASON OF UNICOMPARTMENTAL KNEE ARTHROPLASTY].

    Science.gov (United States)

    Jia, Di; Li, Yanlin; Wang, Guoliang; Gao, Huanyu; Yu, Yang

    2016-01-01

    To conclude the revision reason of unicompartmental knee arthroplasty (UKA) using computer-assisted technology so as to provide reference for reducing the revision incidence and improving the level of surgical technique and rehabilitation. The relevant literature on analyzing revision reason of UKA using computer-assisted technology in recent years was extensively reviewed. The revision reasons by computer-assisted technology are fracture of the medial tibial plateau, progressive osteoarthritis of reserved compartment, dislocation of mobile bearing, prosthesis loosening, polyethylene wear, and unexplained persistent pain. Computer-assisted technology can be used to analyze the revision reason of UKA and guide the best operating method and rehabilitation scheme by simulating the operative process and knee joint activities.

  11. Computer Assisted Language Learning (CALL) Software: Evaluation ...

    African Journals Online (AJOL)

    Evaluating the nature and extent of the influence of Computer Assisted Language Learning (CALL) on the quality of language learning is highly problematic. This is owing to the number and complexity of interacting variables involved in setting the items for teaching and learning languages. This paper identified and ...

  12. ITER diagnostic system: Vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K.M., E-mail: Kaushal.Patel@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Drevon, J.M. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Encheva, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Kashchuk, Y. [Institution “PROJECT CENTER ITER”, 1, Akademika Kurchatova pl., Moscow (Russian Federation); Maquet, Ph. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France)

    2013-10-15

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10{sup −7} Pa, irrespective of plasma operation, and a leak rate of less than 10{sup −10} Pa m{sup 3} s{sup −1}. In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions

  13. ITER diagnostic system: Vacuum interface

    International Nuclear Information System (INIS)

    Patel, K.M.; Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L.; Drevon, J.M.; Encheva, A.; Kashchuk, Y.; Maquet, Ph.; Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J.

    2013-01-01

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10 −7 Pa, irrespective of plasma operation, and a leak rate of less than 10 −10 Pa m 3 s −1 . In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions will be described

  14. Computer Assisted Language Learning” (CALL

    Directory of Open Access Journals (Sweden)

    Nazlı Gündüz

    2005-10-01

    Full Text Available This article will provide an overview of computers; an overview of the history of CALL, itspros and cons, the internet, World Wide Web, Multimedia, and research related to the uses of computers in the language classroom. Also, it also aims to provide some background for the beginnerson using the Internet in language classes today. It discusses some of the common types of Internetactivities that are being used today, what the minimum requirements are for using the Internet forlanguage learning, and some easy activities you can adapt for your classes. Some special terminology related to computers will also be used in this paper. For example, computer assisted language learning(CALL refers to the sets of instructions which need to be loaded into the computer for it to be able to work in the language classroom. It should be borne in mind that CALL does not refer to the use of acomputer by a teacher to type out a worksheet or a class list or preparing his/her own teaching alone.Hardware refers to any computer equipment used, including the computer itself, the keyboard, screen (or the monitor, the disc-drive, and the printer. Software (computer programs refers to the sets of instructions which need to be loaded into the computer for it to be able to work.

  15. An object-oriented-database-system to assist control room staff

    Energy Technology Data Exchange (ETDEWEB)

    Schildt, G H [Vienna Univ. of Technology, Vienna (Austria). Inst. for Automation

    1997-12-31

    In order to assist control room staff of failure of any electrical or mechanical component a new objects-oriented-database-system (OODBS) has been developed and installed. Monitoring and diagnostics may be supported by this OODBS within a well-defined response time. The operator gets a report on different levels: For example, at a first level data about the vendor of a device (like reactor vessel internals, pumps, valves, etc.), data of installation, history of failures since installation, at a second level e.g. technical data of the device, at a next level e.g. a scanned photo of the device with its identification number within a certain compartment, and at another level using a CAD-system presenting technical drawings and corresponding part lists in order to assist necessary communication between operator and maintenance technician. (author). 3 refs, 10 figs.

  16. An object-oriented-database-system to assist control room staff

    International Nuclear Information System (INIS)

    Schildt, G.H.

    1996-01-01

    In order to assist control room staff of failure of any electrical or mechanical component a new objects-oriented-database-system (OODBS) has been developed and installed. Monitoring and diagnostics may be supported by this OODBS within a well-defined response time. The operator gets a report on different levels: For example, at a first level data about the vendor of a device (like reactor vessel internals, pumps, valves, etc.), data of installation, history of failures since installation, at a second level e.g. technical data of the device, at a next level e.g. a scanned photo of the device with its identification number within a certain compartment, and at another level using a CAD-system presenting technical drawings and corresponding part lists in order to assist necessary communication between operator and maintenance technician. (author). 3 refs, 10 figs

  17. Computer automation of a dilution cryogenic system

    International Nuclear Information System (INIS)

    Nogues, C.

    1992-09-01

    This study has been realized in the framework of studies on developing new technic for low temperature detectors for neutrinos and dark matter. The principles of low temperature physics and helium 4 and dilution cryostats, are first reviewed. The cryogenic system used and the technic for low temperature thermometry and regulation systems are then described. The computer automation of the dilution cryogenic system involves: numerical measurement of the parameter set (pressure, temperature, flow rate); computer assisted operating of the cryostat and the pump bench; numerical regulation of pressure and temperature; operation sequence full automation allowing the system to evolve from a state to another (temperature descent for example)

  18. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians.

    Science.gov (United States)

    Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir

    2013-01-01

    We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Conversation Analysis in Computer-Assisted Language Learning

    Science.gov (United States)

    González-Lloret, Marta

    2015-01-01

    The use of Conversation Analysis (CA) in the study of technology-mediated interactions is a recent methodological addition to qualitative research in the field of Computer-assisted Language Learning (CALL). The expansion of CA in Second Language Acquisition research, coupled with the need for qualitative techniques to explore how people interact…

  20. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  1. Using computer assisted learning for clinical skills education in nursing: integrative review.

    Science.gov (United States)

    Bloomfield, Jacqueline G; While, Alison E; Roberts, Julia D

    2008-08-01

    This paper is a report of an integrative review of research investigating computer assisted learning for clinical skills education in nursing, the ways in which it has been studied and the general findings. Clinical skills are an essential aspect of nursing practice and there is international debate about the most effective ways in which these can be taught. Computer assisted learning has been used as an alternative to conventional teaching methods, and robust research to evaluate its effectiveness is essential. The CINAHL, Medline, BNI, PsycInfo and ERIC electronic databases were searched for the period 1997-2006 for research-based papers published in English. Electronic citation tracking and hand searching of reference lists and relevant journals was also undertaken. Twelve studies met the inclusion criteria. An integrative review was conducted and each paper was explored in relation to: design, aims, sample, outcome measures and findings. Many of the study samples were small and there were weaknesses in designs. There is limited empirical evidence addressing the use of computer assisted learning for clinical skills education in nursing. Computer assisted learning has been used to teach a limited range of clinical skills in a variety of settings. The paucity of evaluative studies indicates the need for more rigorous research to investigate the effect of computer assisted learning for this purpose. Areas that need to be addressed in future studies include: sample size, range of skills, longitudinal follow-up and control of confounding variables.

  2. Development of an Adaptable Display and Diagnostic System for the Evaluation of Tropical Cyclone Forecasts

    Science.gov (United States)

    Kucera, P. A.; Burek, T.; Halley-Gotway, J.

    2015-12-01

    NCAR's Joint Numerical Testbed Program (JNTP) focuses on the evaluation of experimental forecasts of tropical cyclones (TCs) with the goal of developing new research tools and diagnostic evaluation methods that can be transitioned to operations. Recent activities include the development of new TC forecast verification methods and the development of an adaptable TC display and diagnostic system. The next generation display and diagnostic system is being developed to support evaluation needs of the U.S. National Hurricane Center (NHC) and broader TC research community. The new hurricane display and diagnostic capabilities allow forecasters and research scientists to more deeply examine the performance of operational and experimental models. The system is built upon modern and flexible technology that includes OpenLayers Mapping tools that are platform independent. The forecast track and intensity along with associated observed track information are stored in an efficient MySQL database. The system provides easy-to-use interactive display system, and provides diagnostic tools to examine forecast track stratified by intensity. Consensus forecasts can be computed and displayed interactively. The system is designed to display information for both real-time and for historical TC cyclones. The display configurations are easily adaptable to meet the needs of the end-user preferences. Ongoing enhancements include improving capabilities for stratification and evaluation of historical best tracks, development and implementation of additional methods to stratify and compute consensus hurricane track and intensity forecasts, and improved graphical display tools. The display is also being enhanced to incorporate gridded forecast, satellite, and sea surface temperature fields. The presentation will provide an overview of the display and diagnostic system development and demonstration of the current capabilities.

  3. Reduce in Variation and Improve Efficiency of Target Volume Delineation by a Computer-Assisted System Using a Deformable Image Registration Approach

    International Nuclear Information System (INIS)

    Chao, K.S. Clifford; Bhide, Shreerang FRCR; Chen, Hansen; Asper, Joshua PAC; Bush, Steven; Franklin, Gregg; Kavadi, Vivek; Liengswangwong, Vichaivood; Gordon, William; Raben, Adam; Strasser, Jon; Koprowski, Christopher; Frank, Steven; Chronowski, Gregory; Ahamad, Anesa; Malyapa, Robert; Zhang Lifei; Dong Lei

    2007-01-01

    Purpose: To determine whether a computer-assisted target volume delineation (CAT) system using a deformable image registration approach can reduce the variation of target delineation among physicians with different head and neck (HN) IMRT experiences and reduce the time spent on the contouring process. Materials and Methods: We developed a deformable image registration method for mapping contours from a template case to a patient case with a similar tumor manifestation but different body configuration. Eight radiation oncologists with varying levels of clinical experience in HN IMRT performed target delineation on two HN cases, one with base-of-tongue (BOT) cancer and another with nasopharyngeal cancer (NPC), by first contouring from scratch and then by modifying the contours deformed by the CAT system. The gross target volumes were provided. Regions of interest for comparison included the clinical target volumes (CTVs) and normal organs. The volumetric and geometric variation of these regions of interest and the time spent on contouring were analyzed. Results: We found that the variation in delineating CTVs from scratch among the physicians was significant, and that using the CAT system reduced volumetric variation and improved geometric consistency in both BOT and NPC cases. The average timesaving when using the CAT system was 26% to 29% for more experienced physicians and 38% to 47% for the less experienced ones. Conclusions: A computer-assisted target volume delineation approach, using a deformable image-registration method with template contours, was able to reduce the variation among physicians with different experiences in HN IMRT while saving contouring time

  4. Computer-Assisted Language Learning: Diversity in Research and Practice

    Science.gov (United States)

    Stockwell, Glenn, Ed.

    2012-01-01

    Computer-assisted language learning (CALL) is an approach to teaching and learning languages that uses computers and other technologies to present, reinforce, and assess material to be learned, or to create environments where teachers and learners can interact with one another and the outside world. This book provides a much-needed overview of the…

  5. A computer-aided continuous assessment system

    Directory of Open Access Journals (Sweden)

    B. C.H. Turton

    1996-12-01

    Full Text Available Universities within the United Kingdom have had to cope with a massive expansion in undergraduate student numbers over the last five years (Committee of Scottish University Principals, 1993; CVCP Briefing Note, 1994. In addition, there has been a move towards modularization and a closer monitoring of a student's progress throughout the year. Since the price/performance ratio of computer systems has continued to improve, Computer- Assisted Learning (CAL has become an attractive option. (Fry, 1990; Benford et al, 1994; Laurillard et al, 1994. To this end, the Universities Funding Council (UFQ has funded the Teaching and Learning Technology Programme (TLTP. However universities also have a duty to assess as well as to teach. This paper describes a Computer-Aided Assessment (CAA system capable of assisting in grading students and providing feedback. In this particular case, a continuously assessed course (Low-Level Languages of over 100 students is considered. Typically, three man-days are required to mark one assessed piece of coursework from the students in this class. Any feedback on how the questions were dealt with by the student are of necessity brief. Most of the feedback is provided in a tutorial session that covers the pitfalls encountered by the majority of the students.

  6. Computer-to-process interface in JET's control and diagnostic systems

    International Nuclear Information System (INIS)

    Fullard, K.; Dorling, S.; Van Montfoort, J.

    1987-01-01

    The JET Control and Data Acquisition System, CODAS, uses some 40,000 electrical signals to control and monitor JET's various systems. This paper describes the electronic equipment and the data transmission techniques which are used to route these signals to and from the centrally-located computers. Special emphasis has been placed on the practical aspects of building and maintaining such a large system of approaching 8,000 modules. Quantities and costs of the various classes of modules and cables are given together with an outline of the quality assurance and organisational techniques adopted

  7. A Study on Remote On-Line Diagnostic System for Vehicles by Integrating the Technology of OBD, GPS, and 3G

    OpenAIRE

    Jyong Lin; Shih-Chang Chen; Yu-Tsen Shih; Shi-Huang Chen

    2009-01-01

    This paper presents a remote on-line diagnostic system for vehicles via the use of On-Board Diagnostic (OBD), GPS, and 3G techniques. The main parts of the proposed system are on-board computer, vehicle monitor server, and vehicle status browser. First, the on-board computer can obtain the location of deriver and vehicle status from GPS receiver and OBD interface, respectively. Then on-board computer will connect with the vehicle monitor server through 3G network to trans...

  8. Comparative cost analysis -- computed tomography vs. alternative diagnostic procedures, 1977-1980

    International Nuclear Information System (INIS)

    Gempel, P.A.; Harris, G.H.; Evans, R.G.

    1977-12-01

    In comparing the total national cost of utilizing computed tomography (CT) for medically indicated diagnoses with that of conventional x-ray, ultrasonography, nuclear medicine, and exploratory surgery, this investigation concludes that there was little, if any, added net cost from CT use in 1977 or will there be in 1980. Computed tomography, generally recognized as a reliable and useful diagnostic modality, has the potential to reduce net costs provided that an optimal number of units can be made available to physicians and patients to achieve projected reductions in alternative procedures. This study examines the actual cost impact of CT on both cranial and body diagnostic procedures. For abdominal and mediastinal disorders, CT scanning is just beginning to emerge as a diagnostic modality. As such, clinical experience is somewhat limited and the authors assume that no significant reduction in conventional procedures took place in 1977. It is estimated that the approximately 375,000 CT body procedures performed in 1977 represent only a 5 percent cost increase over use of other diagnostic modalities. It is projected that 2,400,000 CT body procedures will be performed in 1980 and, depending on assumptions used, total body diagnostic costs will increase only slightly or be reduced. Thirty-one tables appear throughout the text presenting cost data broken down by types of diagnostic procedures used and projections by years. Appendixes present technical cost components for diagnostic procedures, the comparative efficacy of CT as revealed in abstracts of published literature, selected medical diagnoses, and references

  9. Handbook of technical diagnostics fundamentals and application to structures and systems

    CERN Document Server

    2013-01-01

    This book presents concepts, methods and techniques to examine symptoms of faults and failures of structures, systems and components and to monitor functional performance and structural integrity. The book is organized in five parts. Part A introduces the scope and application of technical diagnostics and gives a comprehensive overview of the physics of failure. Part B presents all relevant methods and techniques for diagnostics and monitoring: from stress, strain, vibration analysis, nondestructive evaluation, thermography and industrial radiology to computed tomography and subsurface microstructural analysis. Part C cores the principles and concepts of technical failure analysis, illustrates case studies, and outlines machinery diagnostics with an emphasis on tribological systems. Part D describes the application of structural health monitoring and performance control to plants and the technical infrastructure, including buildings, bridges, pipelines, electric power stations, offshore wind structures, and r...

  10. Computer-based diagnostic decisionmaking.

    Science.gov (United States)

    Miller, R A

    1987-12-01

    The three decisionmaking aids described by the authors attack the generic problem of "see no evil, hear no evil, speak no evil"--improving the detection, diagnosis, and therapy of psychiatric disorders in the primary care setting. The three systems represent interventions at different steps in the process of providing appropriate care to psychiatric patients. The DSPW system of Robins and Marcus offers the potential of increasing the recognition of psychiatric disease in the physician's office. Politser's IDS program is representative of the sort of sophisticated microcomputer-based decisionmaking support tools that will become available to physicians in the not-too-distant future. Erdman's study of the impact of explanation capabilities on the acceptability of therapy recommending systems points out the need for careful scientific evaluations of features added to diagnostic and therapeutic systems.

  11. Computer assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.; Rhodes, M.L.; Jaffee, C.C.; Felix, R.

    1987-01-01

    The organization of the book follows the plan of the meeting, with chapters representing the general meeting sessions and articles representing the meeting presentations. These are grouped by modality or kindred application, where relevant. Some sessions are not similarly divided and individual papers are positioned, presumably, in order of presentation. Each section labeled workshop addresses a specific topic. The first session is on digital image generation and contains sections on magnetic resonance imaging, nuclear medicine, computed tomography, ultrasound, digital radiography, and digital subtraction and angiography. The remaining sections are on application programming, picture archiving and communications systems, computer graphics, and computer vision

  12. A computer assisted toolholder to guide surgery in stereotactic space.

    Science.gov (United States)

    Giorgi, C; Pluchino, F; Luzzara, M; Ongania, E; Casolino, D S

    1994-01-01

    A computer assisted toolholder, integrated with an anatomical graphic 3-D rendering programme, is presented. Stereotactic neuroanatomical images are acquired, and the same reference system is employed to represent the position of the toolholder on the monitor. The surgeon can check the orientation of different approach trajectories, moving the toolholder in a situation of virtual reality. Angular values expressed by high precision encoders on the five joints of the toolholder modify "on line" the representation of the configuration of the toolholder within the three dimensional representation of the patient's anatomy.

  13. Performance analysis of a solar-assisted swimming pool heating system

    Energy Technology Data Exchange (ETDEWEB)

    Alkhamis, A I; Sherif, S A [Miami Univ., Coral Gables, FL (United States). Dept. of Mechanical Engineering

    1991-12-31

    This paper discusses feasibility studies for a solar-assisted heating system using a computer simulation program. The solar heating is accomplished by employing hot water generated by heat exchange with the solar collector working fluid. The performance of the system is analysed from both thermodynamic and economic standpoints and general conclusions are reached. 17 refs., 7 figs.

  14. Chemistry monitoring and diagnostic system at NPP Jaslovske Bohunice

    International Nuclear Information System (INIS)

    Smiesko, Ivan; Figedy, Stefan

    2012-09-01

    This paper provides a description of water chemistry monitoring and diagnostic system installed at Slovak NPP Jaslovske Bohunice. System has complex architecture and covers laboratory data, chemistry and radiochemistry on-line monitoring data, process data acquisition and processing and diagnostics. Pre-filtered data from process computer and chemistry on-line monitors are recorded together with laboratory data in the ORACLE-based information system CHEMIS with many presentation and processing features. Brief information is given about the basic features of a newly developed diagnostic system for early detection and identification of anomalies incoming in the water chemistry regime of the primary and secondary circuit of VVER-440 type unit. This system, called SACHER (System of Analysis of Chemical Regime) has been installed within the major modernization project at the NPP Bohunice in the Slovak Republic. System SACHER has been developed fully in MATLAB environment. Diagnostic system works exclusively with available on-line data as an operation personnel support application allowing effective response to adverse chemistry events/trends. The availability of prompt information about the chemical conditions of the primary and secondary circuit is very important in order to prevent the undue corrosion and deposit build-up processes within the plant systems. The typical chemical information systems that exist and work at the NPPs give the user values of the measured quantities together with their time trends and other derived values. It is then the experienced user's role to recognize the situation the monitored process is in and make the subsequent decisions and take the measures. The SACHER system, based on the computational intelligence techniques, inserts the elements of intelligence into the overall chemical information system. It has the modular structure with the following most important modules: - normality module- its aim is to recognize that the process

  15. Towards intelligent diagnostic system employing integration of mathematical and engineering model

    International Nuclear Information System (INIS)

    Isa, Nor Ashidi Mat

    2015-01-01

    The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well

  16. Towards intelligent diagnostic system employing integration of mathematical and engineering model

    Science.gov (United States)

    Isa, Nor Ashidi Mat

    2015-05-01

    The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well

  17. Towards intelligent diagnostic system employing integration of mathematical and engineering model

    Energy Technology Data Exchange (ETDEWEB)

    Isa, Nor Ashidi Mat [Imaging and Intelligent System Research Team (ISRT), School of Electrical and Electronic Engineering, Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang (Malaysia)

    2015-05-15

    The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well

  18. Personalized Computer-Assisted Mathematics Problem-Solving Program and Its Impact on Taiwanese Students

    Science.gov (United States)

    Chen, Chiu-Jung; Liu, Pei-Lin

    2007-01-01

    This study evaluated the effects of a personalized computer-assisted mathematics problem-solving program on the performance and attitude of Taiwanese fourth grade students. The purpose of this study was to determine whether the personalized computer-assisted program improved student performance and attitude over the nonpersonalized program.…

  19. MONTHLY VARIATION IN SPERM MOTILITY IN COMMON CARP ASSESSED USING COMPUTER-ASSISTED SPERM ANALYSIS (CASA)

    Science.gov (United States)

    Sperm motility variables from the milt of the common carp Cyprinus carpio were assessed using a computer-assisted sperm analysis (CASA) system across several months (March-August 1992) known to encompass the natural spawning period. Two-year-old pond-raised males obtained each mo...

  20. Scaling-Up the Functional Diagnostic Systems

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2008-01-01

    Functional diagnostic systems received a lot of attention in the last decade. They have proven their powerful for diagnosis the new faults of some complex systems. But, they still have some complexity in both the representation and reasoning about the large-scale systems. This paper introduces a new functional diagnostic system that can divide its small functions into main and auxiliary ones. This process enables the diagnostic system to scale -up the representation of the tested system and simplify the diagnostic mechanism tasks. Thus, it can improve both the representation and reasoning complexity. Also,it can decrease the required analysis, cost, and time. Proposed system can be applied for a wide area of the large-scale systems. It has been proven its acceptance to be applied practically for the Complex real-time systems

  1. Investigation into diagnostic agreement using automated computer-assisted histopathology pattern recognition image analysis

    Directory of Open Access Journals (Sweden)

    Joshua D Webster

    2012-01-01

    Full Text Available The extent to which histopathology pattern recognition image analysis (PRIA agrees with microscopic assessment has not been established. Thus, a commercial PRIA platform was evaluated in two applications using whole-slide images. Substantial agreement, lacking significant constant or proportional errors, between PRIA and manual morphometric image segmentation was obtained for pulmonary metastatic cancer areas (Passing/Bablok regression. Bland-Altman analysis indicated heteroscedastic measurements and tendency toward increasing variance with increasing tumor burden, but no significant trend in mean bias. The average between-methods percent tumor content difference was -0.64. Analysis of between-methods measurement differences relative to the percent tumor magnitude revealed that method disagreement had an impact primarily in the smallest measurements (tumor burden 0.988, indicating high reproducibility for both methods, yet PRIA reproducibility was superior (C.V.: PRIA = 7.4, manual = 17.1. Evaluation of PRIA on morphologically complex teratomas led to diagnostic agreement with pathologist assessments of pluripotency on subsets of teratomas. Accommodation of the diversity of teratoma histologic features frequently resulted in detrimental trade-offs, increasing PRIA error elsewhere in images. PRIA error was nonrandom and influenced by variations in histomorphology. File-size limitations encountered while training algorithms and consequences of spectral image processing dominance contributed to diagnostic inaccuracies experienced for some teratomas. PRIA appeared better suited for tissues with limited phenotypic diversity. Technical improvements may enhance diagnostic agreement, and consistent pathologist input will benefit further development and application of PRIA.

  2. Investigation into diagnostic agreement using automated computer-assisted histopathology pattern recognition image analysis.

    Science.gov (United States)

    Webster, Joshua D; Michalowski, Aleksandra M; Dwyer, Jennifer E; Corps, Kara N; Wei, Bih-Rong; Juopperi, Tarja; Hoover, Shelley B; Simpson, R Mark

    2012-01-01

    The extent to which histopathology pattern recognition image analysis (PRIA) agrees with microscopic assessment has not been established. Thus, a commercial PRIA platform was evaluated in two applications using whole-slide images. Substantial agreement, lacking significant constant or proportional errors, between PRIA and manual morphometric image segmentation was obtained for pulmonary metastatic cancer areas (Passing/Bablok regression). Bland-Altman analysis indicated heteroscedastic measurements and tendency toward increasing variance with increasing tumor burden, but no significant trend in mean bias. The average between-methods percent tumor content difference was -0.64. Analysis of between-methods measurement differences relative to the percent tumor magnitude revealed that method disagreement had an impact primarily in the smallest measurements (tumor burden 0.988, indicating high reproducibility for both methods, yet PRIA reproducibility was superior (C.V.: PRIA = 7.4, manual = 17.1). Evaluation of PRIA on morphologically complex teratomas led to diagnostic agreement with pathologist assessments of pluripotency on subsets of teratomas. Accommodation of the diversity of teratoma histologic features frequently resulted in detrimental trade-offs, increasing PRIA error elsewhere in images. PRIA error was nonrandom and influenced by variations in histomorphology. File-size limitations encountered while training algorithms and consequences of spectral image processing dominance contributed to diagnostic inaccuracies experienced for some teratomas. PRIA appeared better suited for tissues with limited phenotypic diversity. Technical improvements may enhance diagnostic agreement, and consistent pathologist input will benefit further development and application of PRIA.

  3. Internal plasma diagnostic with a multichannel magnetic probe system using automatic data acquisition

    International Nuclear Information System (INIS)

    Korten, M.; Carolan, P.G.; Sand, F.; Waelbroeck, F.

    1975-04-01

    A 20-channel magnetic probe system inserted into the plasma is used to measure spatial distributions of poloidal and toroidal magnetic fields in the pulsed toroidal high β-experiment TEE. Plasma parameters, e.g. the β-value, toroidal current density and radial pressure distribution were derived applying static equilibrium theory and can be calculated from the measurements. A data acquisition system used in conjuction with a process computer was operated to obtain the experimental data automatically and to perform the multiple computational tasks. The program system described was built to serve as a first stage of a more common software system applicable for computational data handling for different diagnostics of a plasma physics confinement experiment. (orig.) [de

  4. An integrated real-time diagnostic concept using expert systems, qualitative reasoning and quantitative analysis

    International Nuclear Information System (INIS)

    Edwards, R.M.; Lee, K.Y.; Kumara, S.; Levine, S.H.

    1989-01-01

    An approach for an integrated real-time diagnostic system is being developed for inclusion as an integral part of a power plant automatic control system. In order to participate in control decisions and automatic closed loop operation, the diagnostic system must operate in real-time. Thus far, an expert system with real-time capabilities has been developed and installed on a subsystem at the Experimental Breeder Reactor (EBR-II) in Idaho, USA. Real-time simulation testing of advanced power plant concepts at the Pennsylvania State University has been developed and was used to support the expert system development and installation at EBR-II. Recently, the US National Science Foundation (NSF) and the US Department of Energy (DOE) have funded a Penn State research program to further enhance application of real-time diagnostic systems by pursuing implementation in a distributed power plant computer system including microprocessor based controllers. This paper summarizes past, current, planned, and possible future approaches to power plant diagnostic systems research at Penn State. 34 refs., 9 figs

  5. Computer-to-process interface in JET's control and diagnostic systems

    International Nuclear Information System (INIS)

    Fullard, K.; Dorling, S.E.; Montfoort, J.E. van

    1986-01-01

    The JET Control and Data Acquisition System, CODAS, uses some 40,000 electrical signals to control and monitor JET's various systems. This paper describes the electronic equipment and the data transmission techniques which are used to route these signals to and from the centrally-located computers is described. Special emphasis has been placed on the practical aspects of building and maintaining such a large system of approaching 8,000 modules. Quantities and costs of the various classes of modules and cables are given together with an outline of the quality assurance and organisational techniques adopted. (author)

  6. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  7. Evaluation of computer-aided detection and diagnosis systems.

    Science.gov (United States)

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in

  8. Evaluation of a vibration diagnostic system for the detection of spur gear pitting failures

    Science.gov (United States)

    Townsend, Dennis P.; Zakrajsek, James J.

    1993-01-01

    A vibration diagnostic system was used to detect spur gear surface pitting fatigue in a closed-loop spur gear fatigue test rig. The diagnostic system, comprising a personal computer with an analog-to-digital conversion board, a diagnostic system unit, and software, uses time-synchronous averaging of the vibration signal to produce a vibration image of each tooth on any gear in a transmission. Several parameters were analyzed including gear pair stress wave and raw baseband vibration, kurtosis, peak ratios, and others. The system provides limits for the various parameters and gives a warning when the limits are exceeded. Several spur gear tests were conducted with this system and vibration data analyzed at 5-min. intervals. The results presented herein show that the system is fairly effective at detecting spur gear tooth surface fatigue pitting failures.

  9. Different computer-assisted sperm analysis (CASA) systems highly influence sperm motility parameters.

    Science.gov (United States)

    Boryshpolets, S; Kowalski, R K; Dietrich, G J; Dzyuba, B; Ciereszko, A

    2013-10-15

    In this study, we examined different computer-assisted sperm analysis (CASA) systems (CRISMAS, Hobson Sperm Tracker, and Image J CASA) on the exact same video recordings to evaluate the differences in sperm motility parameters related to the specific CASA used. To cover a wide range of sperm motility parameters, we chose 12-second video recordings at 25 and 50 Hz frame rates after sperm motility activation using three taxonomically distinct fish species (sterlet: Acipenser ruthenus L.; common carp: Cyprinus carpio L.; and rainbow trout: Oncorhynchus mykiss Walbaum) that are characterized by essential differences in sperm behavior during motility. Systematically higher values of velocity and beat cross frequency (BCF) were observed in video recordings obtained at 50 Hz frame frequency compared with 25 Hz for all three systems. Motility parameters were affected by the CASA and species used for analyses. Image J and CRISMAS calculated higher curvilinear velocity (VCL) values for rainbow trout and common carp at 25 Hz frequency compared with the Hobson Sperm Tracker, whereas at 50 Hz, a significant difference was observed only for rainbow trout sperm recordings. No significant difference was observed between the CASA systems for sterlet sperm motility at 25 and 50 Hz. Additional analysis of 1-second segments taken at three time points (1, 6, and 12 seconds of the recording) revealed a dramatic decrease in common carp and rainbow trout sperm speed. The motility parameters of sterlet spermatozoa did not change significantly during the 12-second motility period and should be considered as a suitable model for longer motility analyses. Our results indicated that the CASA used can affect motility results even when the same motility recordings are used. These results could be critically altered by the recording quality, time of analysis, and frame rate of camera, and could result in erroneous conclusions. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. High speed imaging system for nuclear diagnostics

    International Nuclear Information System (INIS)

    Eyer, H.H.

    1976-01-01

    A high speed imaging system based on state-of-the-art photosensor arrays has been designed for use in nuclear diagnostics. The system is comprised of a front-end rapid-scan solid-state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in a uphole trailer. The downhole camera takes a ''snapshot'' of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to the LLL computational facility (NADS). The impetus for such a system as well as its operation are discussed. Also discussed are new systems under development which incorporate higher data rates and more resolution

  11. High speed imaging system for nuclear diagnostics

    International Nuclear Information System (INIS)

    Eyer, H.H.

    1976-01-01

    A high speed imaging system based on state-of-the-art photosensor arrays has been designed for use in nuclear diagnostics. The system is comprised of a front-end rapid-scan solid-state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in an uphole trailer. The downhole camera takes a ''snapshot'' of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to the LLL computational facility (NADS). The impetus for such a system as well as its operation is discussed. Also discussed are new systems under development which incorporate higher data rates and more resolution

  12. Computer-assisted training in the thermal production department

    International Nuclear Information System (INIS)

    Felgines, R.

    1985-01-01

    For many years now, in the United States and Canada, computer-assisted training (CAT) experiments have been carried out in various fields: general or professional education, student testing in universities. This method seems very promising and particularly for continuing education and for keeping industrial process operating and maintenance personnel abreast of their specialities. Thanks to the progress in data processing and remote processing with central computers, this technique is being developed in France for professional training applications. Faced with many training problems, the Thermal Production Department of EDF (Electricite de France) first conducted in 1979 a test involving a limited subset of the nuclear power station operating personnel; this course amounted to some ten hours with very limited content. It seemed promising enough, so that in 1981, a real test was launched at 4 PWR plants: DAMPIERRE, FESSENHEIM, GRAVELINES, TRICASTIN. This test which involves about 700 employees has been fruitful and we decided to generalise this system to all the French nuclear power plants (40 units of 900 and 1300 MW). (author)

  13. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  14. Development of a rule-based diagnostic platform on an object-oriented expert system shell

    International Nuclear Information System (INIS)

    Wang, Wenlin; Yang, Ming; Seong, Poong Hyun

    2016-01-01

    Highlights: • Multilevel Flow Model represents system knowledge as a domain map in expert system. • Rule-based fault diagnostic expert system can identify root cause via a causal chain. • Rule-based fault diagnostic expert system can be used for fault simulation training. - Abstract: This paper presents the development and implementation of a real-time rule-based diagnostic platform. The knowledge is acquired from domain experts and textbooks and the design of the fault diagnosis expert system was performed in the following ways: (i) establishing of corresponding classes and instances to build the domain map, (ii) creating of generic fault models based on events, and (iii) building of diagnostic reasoning based on rules. Knowledge representation is a complicated issue of expert systems. One highlight of this paper is that the Multilevel Flow Model has been used to represent the knowledge, which composes the domain map within the expert system as well as providing a concise description of the system. The developed platform is illustrated using the pressure safety system of a pressurized water reactor as an example of the simulation test bed; the platform is developed using the commercial and industrially validated software G2. The emulation test was conducted and it has been proven that the fault diagnosis expert system can identify the faults correctly and in a timely way; this system can be used as a simulation-based training tool to assist operators to make better decisions.

  15. Computer-assisted qualitative data analysis software.

    Science.gov (United States)

    Cope, Diane G

    2014-05-01

    Advances in technology have provided new approaches for data collection methods and analysis for researchers. Data collection is no longer limited to paper-and-pencil format, and numerous methods are now available through Internet and electronic resources. With these techniques, researchers are not burdened with entering data manually and data analysis is facilitated by software programs. Quantitative research is supported by the use of computer software and provides ease in the management of large data sets and rapid analysis of numeric statistical methods. New technologies are emerging to support qualitative research with the availability of computer-assisted qualitative data analysis software (CAQDAS).CAQDAS will be presented with a discussion of advantages, limitations, controversial issues, and recommendations for this type of software use.

  16. Ethical and Professional Issues in Computer-Assisted Therapy.

    Science.gov (United States)

    Ford, B. Douglas

    1993-01-01

    Discusses ethical and professional issues in psychology regarding computer-assisted therapy (CAT). Topics addressed include an explanation of CAT; whether CAT is psychotherapy; software, including independent use, validation of effectiveness, and restricted access; clinician resistance; client acceptance; the impact on ethical standards; and a…

  17. From Computer Assisted Language Learning (CALL) to Mobile Assisted Language Use (MALU)

    Science.gov (United States)

    Jarvis, Huw; Achilleos, Marianna

    2013-01-01

    This article begins by critiquing the long-established acronym CALL (Computer Assisted Language Learning). We then go on to report on a small-scale study which examines how student non-native speakers of English use a range of digital devices beyond the classroom in both their first (L1) and second (L2) languages. We look also at the extent to…

  18. Climate Model Diagnostic Analyzer Web Service System

    Science.gov (United States)

    Lee, S.; Pan, L.; Zhai, C.; Tang, B.; Kubar, T. L.; Li, J.; Zhang, J.; Wang, W.

    2015-12-01

    Both the National Research Council Decadal Survey and the latest Intergovernmental Panel on Climate Change Assessment Report stressed the need for the comprehensive and innovative evaluation of climate models with the synergistic use of global satellite observations in order to improve our weather and climate simulation and prediction capabilities. The abundance of satellite observations for fundamental climate parameters and the availability of coordinated model outputs from CMIP5 for the same parameters offer a great opportunity to understand and diagnose model biases in climate models. In addition, the Obs4MIPs efforts have created several key global observational datasets that are readily usable for model evaluations. However, a model diagnostic evaluation process requires physics-based multi-variable comparisons that typically involve large-volume and heterogeneous datasets, making them both computationally- and data-intensive. In response, we have developed a novel methodology to diagnose model biases in contemporary climate models and implementing the methodology as a web-service based, cloud-enabled, provenance-supported climate-model evaluation system. The evaluation system is named Climate Model Diagnostic Analyzer (CMDA), which is the product of the research and technology development investments of several current and past NASA ROSES programs. The current technologies and infrastructure of CMDA are designed and selected to address several technical challenges that the Earth science modeling and model analysis community faces in evaluating and diagnosing climate models. In particular, we have three key technology components: (1) diagnostic analysis methodology; (2) web-service based, cloud-enabled technology; (3) provenance-supported technology. The diagnostic analysis methodology includes random forest feature importance ranking, conditional probability distribution function, conditional sampling, and time-lagged correlation map. We have implemented the

  19. Computer-assisted trauma care prototype.

    Science.gov (United States)

    Holzman, T G; Griffith, A; Hunter, W G; Allen, T; Simpson, R J

    1995-01-01

    Each year, civilian accidental injury results in 150,000 deaths and 400,000 permanent disabilities in the United States alone. The timely creation of and access to dynamically updated trauma patient information at the point of injury is critical to improving the state of care. Such information is often non-existent, incomplete, or inaccurate, resulting in less than adequate treatment by medics and the loss of precious time by medical personnel at the hospital or battalion aid station as they attempt to reassess and treat the patient. The Trauma Care Information Management System (TCIMS) is a prototype system for facilitating information flow and patient processing decisions in the difficult circumstances of civilian and military trauma care activities. The program is jointly supported by the United States Advanced Research Projects Agency (ARPA) and a consortium of universities, medical centers, and private companies. The authors' focus has been the human-computer interface for the system. We are attempting to make TCIMS powerful in the functions it delivers to its users in the field while also making it easy to understand and operate. To develop such a usable system, an approach known as user-centered design is being followed. Medical personnel themselves are collaborating with the authors in its needs analysis, design, and evaluation. Specifically, the prototype being demonstrated was designed through observation of actual civilian trauma care episodes, military trauma care exercises onboard a hospital ship, interviews with civilian and military trauma care providers, repeated evaluation of evolving prototypes by potential users, and study of the literature on trauma care and human factors engineering. This presentation at MedInfo '95 is still another avenue for soliciting guidance from medical information system experts and users. The outcome of this process is a system that provides the functions trauma care personnel desire in a manner that can be easily and

  20. Thermodynamic investigation of a booster-assisted ejector refrigeration system

    International Nuclear Information System (INIS)

    Zhao, Hongxia; Zhang, Ke; Wang, Lei; Han, Jitian

    2016-01-01

    Highlights: • COP based on thermal input increases with booster outlet pressure. • Both entrainment ratio and area ratio increase with booster outlet pressure. • COP based on work is larger than compressor-based refrigeration system. • An optimum booster outlet pressure obtains maximum COP based on work. • Exergy destruction occurs mainly in ejector, condenser, evaporator and generator. - Abstract: In order to improve performance of ejector refrigeration system, a booster is added before an ejector to enhance secondary flow pressure, which is called a booster assisted refrigeration system. Based on mass, momentum and energy conservation, a 1D model of ejector for optimal performance prediction was presented and validated with experimental data. A detailed study of working characteristics of the booster assisted ejector refrigeration system was carried out and compared against conventional ejector refrigeration system and compressor based refrigeration system, on the basis of first and second laws of thermodynamics. Effects of booster outlet pressure on COP_t_h based on thermal energy and COP_w based on work input, and also on entrainment ratio and area ratio of ejector were studied. The exergy destruction rates were also computed and analyzed for components of the booster-assisted ejector refrigeration system. Ways to reduce exergy destruction were discussed.

  1. Total knee arthroplasty with computer-assisted navigation: an analysis of 200 cases,

    Directory of Open Access Journals (Sweden)

    Marcus Vinicius Malheiros Luzo

    2014-04-01

    Full Text Available OBJECTIVE: to evaluate the results from surgery with computer-assisted navigation in cases of total knee arthroplasty.METHOD: a total of 196 patients who underwent total knee arthroplasty with computer-assisted navigation were evaluated. The extension and flexion spaces (gaps were evaluated during the operation and the alignment after the operation was assessed. The Knee Society Score (KSS questionnaire for assessing patient's function was applied preoperatively and postoperatively after a mean follow-up of 22 months.RESULTS: in all, 86.7% of the patients presented good alignment of the mechanical axis (less than 3◦ of varus or valgus in relation to the mechanical axis and 96.4% of the patients presented balanced flexion and extension gaps. Before the operation, 97% of the patients presented poor or insufficient KSS, but after the operation, 77.6% presented good or excellent KSS.CONCLUSION: the navigation system made it possible to achieve aligned and balanced implants, with notable functional improvement among the patients. It was found to be useful in assessing, understanding and improving knowledge in relation to performing arthroplasty procedures.

  2. On Using Intelligent Computer-Assisted Language Learning in Real-Life Foreign Language Teaching and Learning

    Science.gov (United States)

    Amaral, Luiz A.; Meurers, Detmar

    2011-01-01

    This paper explores the motivation and prerequisites for successful integration of Intelligent Computer-Assisted Language Learning (ICALL) tools into current foreign language teaching and learning (FLTL) practice. We focus on two aspects, which we argue to be important for effective ICALL system development and use: (i) the relationship between…

  3. Computerized systems for on-line management of failures: a state-of-the-art discussion of alarm systems and diagnostic systems applied in the nuclear industry

    International Nuclear Information System (INIS)

    Kim, I.S.

    1994-01-01

    It is now well perceived in the nuclear industry that improving plant information systems is vital for enhancing the operational safety of nuclear power plants. Considerable work is underway worldwide to support operators' decision-making, particularly in their difficult tasks of managing process anomalies on-line. The work includes development of (1) advanced alarm systems, such as various kinds of computer-based alarm processing systems, Critical Function Monitoring System, Success Path Monitoring System and Safety Assessment System II, and (2) real-timer diagnostic systems, such as Disturbance Analysis System, Maryland Operator Advisory System II, Model-Integrated Diagnostic Analysis System, Diagnosis System using Knowledge Engineering Technique, Detailed Diagnosis, and Operator Advisor System. This paper presents a state-of-the-art review of plant information systems for on-line management of failures in nuclear power plants, focusing on the methodological features of computerized alarm systems and diagnostic systems. (author)

  4. 45 CFR 233.35 - Computing the assistance payment under retrospective budgeting after the initial one or two...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Computing the assistance payment under... FINANCIAL ASSISTANCE PROGRAMS § 233.35 Computing the assistance payment under retrospective budgeting after... shall be computed retrospectively, i.e., shall be based on income and other relevant circumstances in...

  5. Innovation in engineering education through computer assisted learning and virtual university model

    Science.gov (United States)

    Raicu, A.; Raicu, G.

    2015-11-01

    The paper presents the most important aspects of innovation in Engineering Education using Computer Assisted Learning. The authors propose to increase the quality of Engineering Education programs of study at European standards. The use of computer assisted learning methodologies in all studies is becoming an important resource in Higher Education. We intend to improve the concept of e-Learning using virtual terminals, online support and assisting special training through live seminars and interactive labs to develop a virtual university model. We intend to encourage computer assisted learning and innovation as sources of competitive advantage, to permit vision and learning analysis, identifies new sources of technology and ideas. Our work is based on our university datasets collected during last fifteen years using several e-Learning systems. In Constanta Maritime University (CMU), using eLearning and Knowledge Management Services (KMS) is very important and we apply it effectively to achieve strategic objectives, such as collaboration, sharing and good practice. We have experience in this field since 2000 year using Moodle as KMS in our university. The term KMS can be associated to Open Source Software, Open Standards, Open Protocols and Open Knowledge licenses, initiatives and policies. In CMU Virtual Campus we have today over 12500 active users. Another experience of the authors is the implementation of MariTrainer Wiki educational platform based on Dokeos and DekiWiki under MARICOMP and MEP Leonardo da Vinci Project. We'll also present in this paper a case study under EU funded project POSDRU, where the authors implemented other educational platform in Technological High Schools from Romania used over 1000 teachers. Based on large datasets the study tries to improve the concept of e-Learning teaching using the revolutionary technologies. The new concept present in this paper is that the teaching and learning will be interactive and live. The new and modern

  6. Soft Tissue Biomechanical Modeling for Computer Assisted Surgery

    CERN Document Server

    2012-01-01

      This volume focuses on the biomechanical modeling of biological tissues in the context of Computer Assisted Surgery (CAS). More specifically, deformable soft tissues are addressed since they are the subject of the most recent developments in this field. The pioneering works on this CAS topic date from the 1980's, with applications in orthopaedics and biomechanical models of bones. More recently, however, biomechanical models of soft tissues have been proposed since most of the human body is made of soft organs that can be deformed by the surgical gesture. Such models are much more complicated to handle since the tissues can be subject to large deformations (non-linear geometrical framework) as well as complex stress/strain relationships (non-linear mechanical framework). Part 1 of the volume presents biomechanical models that have been developed in a CAS context and used during surgery. This is particularly new since most of the soft tissues models already proposed concern Computer Assisted Planning, with ...

  7. Comprehensive automatic assessment of retinal vascular abnormalities for computer-assisted retinopathy grading.

    Science.gov (United States)

    Joshi, Vinayak; Agurto, Carla; VanNess, Richard; Nemeth, Sheila; Soliz, Peter; Barriga, Simon

    2014-01-01

    One of the most important signs of systemic disease that presents on the retina is vascular abnormalities such as in hypertensive retinopathy. Manual analysis of fundus images by human readers is qualitative and lacks in accuracy, consistency and repeatability. Present semi-automatic methods for vascular evaluation are reported to increase accuracy and reduce reader variability, but require extensive reader interaction; thus limiting the software-aided efficiency. Automation thus holds a twofold promise. First, decrease variability while increasing accuracy, and second, increasing the efficiency. In this paper we propose fully automated software as a second reader system for comprehensive assessment of retinal vasculature; which aids the readers in the quantitative characterization of vessel abnormalities in fundus images. This system provides the reader with objective measures of vascular morphology such as tortuosity, branching angles, as well as highlights of areas with abnormalities such as artery-venous nicking, copper and silver wiring, and retinal emboli; in order for the reader to make a final screening decision. To test the efficacy of our system, we evaluated the change in performance of a newly certified retinal reader when grading a set of 40 color fundus images with and without the assistance of the software. The results demonstrated an improvement in reader's performance with the software assistance, in terms of accuracy of detection of vessel abnormalities, determination of retinopathy, and reading time. This system enables the reader in making computer-assisted vasculature assessment with high accuracy and consistency, at a reduced reading time.

  8. Computer-assisted instruction; MR imaging of congenital heart disease

    International Nuclear Information System (INIS)

    Choi, Young Hi; Yu, Pil Mun; Lee, Sang Hoon; Choe, Yeon Hyeon; Kim, Yang Min

    1996-01-01

    To develop a software program for computer-assisted instruction on MR imaging of congenital heart disease for medical students and residents to achieve repetitive and effective self-learning. We used a film scanner(Scan Maker 35t) and IBM-PC(486 DX-2, 60 MHz) for acquisition and storage of image data. The accessories attached to the main processor were CD-ROM drive(Sony), sound card(Soundblaster-Pro), and speaker. We used software of Adobe Photoshop(v 3.0) and paint shop-pro(v 3.0) for preprocessing image data, and paintbrush from microsoft windows 3.1 for labelling. The language used for programming was visual basic(v 3.0) from microsoft corporation. We developed a software program for computer-assisted instruction on MR imaging of congenital heart disease as an effective educational tool

  9. Secondary School Mathematics Teachers’ and Students’ Views on Computer Assisted Mathematics Instruction in Turkey: Mathematica Example

    OpenAIRE

    Mehmet Alper Ardıç; Tevfik İşleyen

    2017-01-01

    This study aimed at determining the secondary school mathematics teachers’ and students’ views on computer-assisted mathematics instruction (CAMI) conducted via Mathematica. Accordingly, three mathematics teachers in Adıyaman and nine 10th-grade students participated in the research. Firstly, the researchers trained the mathematics teachers in the Mathematica program, a computer algebra system (CAS) and CAMI. Then, they provided a suitable environment for teachers to practice CAMI with their ...

  10. Computer Assisted Project-Based Instruction: The Effects on Science Achievement, Computer Achievement and Portfolio Assessment

    Science.gov (United States)

    Erdogan, Yavuz; Dede, Dinçer

    2015-01-01

    The purpose of this study is to compare the effects of computer assisted project-based instruction on learners' achievement in a science and technology course, in a computer course and in portfolio development. With this aim in mind, a quasi-experimental design was used and a sample of 70 seventh grade secondary school students from Org. Esref…

  11. BIOTECHNICAL SYSTEM FOR INTEGRATED OLFACTOMETRY DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    Yana Nosova

    2017-09-01

    Full Text Available The subject matter of the article is the process of olfactometric research of a human olfactory function. The object of the study is a biotechnical system which includes a method for increasing the objectivity of olfactometric diagnostics. The goal is to develop a biotechnical system for complex olfactometry, which enables increasing the objectivity of olfactometric studies and connecting breathing parameters with olfactory function by placing an odorant carrier in the airway of the rhinomanometer, as well as by using procedures for determining the energy characteristics of respiration. The methods used are: methods of digital signal processing, the theory of biotechnical systems. The following results are obtained. A structural diagram of a biotechnical system for olfactometric diagnostics of a human olfactory analyser was developed. As a result of the analysis of the cyclogram of nasal breathing, it is found that by changing the frequency and nature of breathing upon reaching the sensitivity threshold, it is possible to objectify the method of assessing respiratory and olfactory disorders according to the energy criterion of pneumatic power when inhaling appropriate odorivectors, and also to study the olfactory and respiratory function with the capability of estimating respiratory cycles in a dynamic mode. The studies were carried out on the basis of typical inspiration cycles: with a quiet breathing in the normal conditions, in the forceful breathing mode with a stiff nasal valve, with a nasal valve with natural functional mobility which restricts the flow of air, and also a stepped inspiration – a short “sipping” of air, which can be characterized as a kind of “sniffing”. Conclusions. Computer olfactometry is one of the most promising methods for diagnosing olfactory disorders of respiratory genesis. The developed biotechnical system is based on the use of a fundamentally new design, combining a rhinomanometer and an olfactometric

  12. Some aspects of diagnostic systems perspective

    International Nuclear Information System (INIS)

    Korosec, D.

    1998-01-01

    The integrity and safety of all nuclear power plant systems and components is guaranteed by the high requirements to quality assurance during all phases of design, fabrication, construction and operation. Many of the countries operating nuclear facilities, introduced advanced, sophisticated diagnostic systems for continuous monitoring safety important process parameters. The licensee should perform an assessment of the existing diagnostic systems, often supplied by the original design, their reliability and the need for the introduction of the additional monitoring/diagnostic systems. The operating experience should be taken into account and the assessment of the further needs. On this field has to be made on the results of PSA studies. In addition to the cost benefit analysis the evaluation of the new diagnostic systems in the light of nuclear safety should be also made. Experience, gained from the utilities, which have already installed this kind of the equipment should be very useful. Introducing new diagnostic systems will require often a safety assessment of the necessary modifications. Licensing process should be based on the existing nuclear legislation with certain additional requirements. (author)

  13. The microcomputer in the dental office: a new diagnostic aid.

    Science.gov (United States)

    van der Stelt, P F

    1985-06-01

    The first computer applications in the dental office were based upon standard accountancy procedures. Recently, more and more computer applications have become available to meet the specific requirements of dental practice. This implies not only business procedures, but also facilities to store patient records in the system and retrieve them easily. Another development concerns the automatic calculation of diagnostic data such as those provided in cephalometric analysis. Furthermore, growth and surgical results in the craniofacial area can be predicted by computerized extrapolation. Computers have been useful in obtaining the patient's anamnestic data objectively and for the making of decisions based on such data. Computer-aided instruction systems have been developed for undergraduate students to bridge the gap between textbook and patient interaction without the risks inherent in the latter. Radiology will undergo substantial changes as a result of the application of electronic imaging devices instead of the conventional radiographic films. Computer-assisted electronic imaging will enable image processing, image enhancement, pattern recognition and data transmission for consultation and storage purposes. Image processing techniques will increase image quality whilst still allowing low-dose systems. Standardization of software and system configuration and the development of 'user friendly' programs is the major concern for the near future.

  14. Computer-Assisted Inverse Design of Inorganic Electrides

    Directory of Open Access Journals (Sweden)

    Yunwei Zhang

    2017-02-01

    Full Text Available Electrides are intrinsic electron-rich materials enabling applications as excellent electron emitters, superior catalysts, and strong reducing agents. There are a number of organic electrides; however, their instability at room temperature and sensitivity to moisture are bottlenecks for their practical uses. Known inorganic electrides are rare, but they appear to have greater thermal stability at ambient conditions and are thus better characterized for application. Here, we develop a computer-assisted inverse-design method for searching for a large variety of inorganic electrides unbiased by any known electride structures. It uses the intrinsic property of interstitial electron localization of electrides as the global variable function for swarm intelligence structure searches. We construct two rules of thumb on the design of inorganic electrides pointing to electron-rich ionic systems and low electronegativity of the cationic elements involved. By screening 99 such binary compounds through large-scale computer simulations, we identify 24 stable and 65 metastable new inorganic electrides that show distinct three-, two-, and zero-dimensional conductive properties, among which 18 are existing compounds that have not been pointed to as electrides. Our work reveals the rich abundance of inorganic electrides by providing 33 hitherto unexpected structure prototypes of electrides, of which 19 are not in the known structure databases.

  15. Role of scintigraphy and computer-assisted tomography in brain examination

    International Nuclear Information System (INIS)

    Akerman, M.; Oproiu, A.; Comoy, C.; Guiot, G.

    1981-01-01

    To assess the role of computer-assisted tomography (CAT) and scintigraphy in brain exploration, the authors analysed: (1) the diagnostic effectiveness of the two methods in 300 patients examined over a period of seven months; (2) the role assigned to each investigation in 169 patients operated on for intracranial lesion during the same period. The isotopic brain examination always included an initial angiographic study after the intravenous injection of a technetium compound. Study of the circulation of the cerebrospinal fluid was made with 111 In-DTPA. The detection efficiency of CAT is higher than for scintigraphy in expansive processes, whereas, conversely, in cerebrovascular accidents of ischaemic origin, isotope angiography coupled with static imaging enables one to gain more information on cerebral perfusion than CAT. Similarly, when studying the cerebrospinal fluid, scintigraphy provides a greater amount of specific data on the mechanisms governing hydrocephalus, the mode of operation of a shunt, or the site of a cerebrospinal fluid fistula. Within a neurosurgical context, CAT by and large takes precedence in brain examination, but the investigation is usually accompanied by scintigraphy or a conventional neuroradiological examination. Scintigraphy was performed on 66% of the patients, whereas for neuroradiological examination the figure was 44%. Most of the scintigraphy came after CAT so as to obtain additional diagnostic information on the vascularization, the nature and, on occasion, the exact location of the lesion revealed by CAT. In more than one case out of two, scintigraphy provides enough additional information for one to avoid neuroradiological examination, which is more 'aggressive' and more dangerous. Hence scintigraphy represents an effective complement to CAT and can compete with the conventional neuroradiological technique. (author)

  16. Operational experiences on the Borssele nuclear power plant using computer based surveillance and diagnostic system on-line

    International Nuclear Information System (INIS)

    Turkcan, E.; Quaadvliet, W.H.J.; Peeters, T.T.J.M.; Verhoef, J.P

    1991-06-01

    The on-line monitoring and diagnostics system of Borssele nuclear power plant (NPP), designed and established by the ECN Energy Research Foundation, has been operating continuously since 1983. The system is extended in form of multiprocessing, multi-tasking structure performing real-time monitoring, on-line reactor parameters' calculation, data-base preparation for expert systems and providing early information on possible malfunctions even in the incipient stage making alert by passive alarms. The system realized has already been operating in the course of 7 fuel cycles of the reactor starting from start-up through normal power operation. An expert system operating on the VAX work station is added to the surveillance and diagnostics system for data base management of the observed physical parameters relevant to the NPP under supervision. The paper highlights the surveillance and diagnostic modules involved, in their actual hierarchical form in use, presents theoretical considerations applied to the design of the surveillance system together with the results obtained through the 12th to 17th fuel cycles of the NPP including start-ups and shut-downs and reveals the experience thus gained by both utility and ECN through the application of the system described. (author). 19 refs.; 4 figs

  17. Computer-assisted intraoperative visualization of dental implants. Augmented reality in medicine

    International Nuclear Information System (INIS)

    Ploder, O.; Wagner, A.; Enislidis, G.; Ewers, R.

    1995-01-01

    In this paper, a recently developed computer-based dental implant positioning system with an image-to-tissue interface is presented. On a computer monitor or in a head-up display, planned implant positions and the implant drill are graphically superimposed on the patient's anatomy. Electromagnetic 3D sensors track all skull and jaw movements; their signal feedback to the workstation induces permanent real-time updating of the virtual graphics' position. An experimental study and a clinical case demonstrates the concept of the augmented reality environment - the physician can see the operating field and superimposed virtual structures, such as dental implants and surgical instruments, without loosing visual control of the operating field. Therefore, the operation system allows visualization of CT planned implantposition and the implementation of important anatomical structures. The presented method for the first time links preoperatively acquired radiologic data, planned implant location and intraoperative navigation assistance for orthotopic positioning of dental implants. (orig.) [de

  18. Next Generation Diagnostic System (NGDS) Increment 1 Early Fielding Report

    Science.gov (United States)

    2017-06-07

    the NGDS production representative configuration, which includes a different laptop computer. System Overview The Services intend for the NGDS to...Powder/Surface Water collected on swabs Soil/Sand Animal Blood Vectors (such as insects) Test Adequacy The data from the OA, supplemented by data...results. The medical provider used NGDS diagnostic results to tailor antibiotic treatment to the specific biological agent identified or to cease

  19. Computer-assisted Orthopaedic Surgery: Current State and Future Perspective

    Directory of Open Access Journals (Sweden)

    Guoyan eZheng

    2015-12-01

    Full Text Available Introduced about two decades ago, computer-assisted orthopaedic surgery (CAOS has emerged as a new and independent area, due to the importance of treatment of musculoskeletal diseases in orthopaedics and traumatology, increasing availability of different imaging modalities, and advances in analytics and navigation tools. The aim of this paper is to present the basic elements of CAOS devices and to review state-of-the-art examples of different imaging modalities used to create the virtual representations, of different position tracking devices for navigation systems, of different surgical robots, of different methods for registration and referencing, and of CAOS modules that have been realized for different surgical procedures. Future perspectives will also be outlined.

  20. Computation of electron cloud diagnostics and mitigation in the main injector

    International Nuclear Information System (INIS)

    Veitzer, S A; Cary, J R; Stoltz, P H; LeBrun, P; Spentzouris, P; Amundson, J F

    2009-01-01

    High-performance computations on Blue Gene/P at Argonne's Leadership Computing Facility have been used to determine phase shifts induced in injected RF diagnostics as a function of electron cloud density in the Main Injector. Inversion of the relationship between electron cloud parameters and induced phase shifts allows us to predict electron cloud density and evolution over many bunch periods. Long time-scale simulations using Blue Gene have allowed us to measure cloud evolution patterns under the influence of beam propagation with realistic physical parameterizations, such as elliptical beam pipe geometry, self-consistent electromagnetic fields, space charge, secondary electron emission, and the application of arbitrary external magnetic fields. Simultaneously, we are able to simulate the use of injected microwave diagnostic signals to measure electron cloud density, and the effectiveness of various mitigation techniques such as surface coating and the application of confining magnetic fields. These simulations provide a baseline for both RF electron cloud diagnostic design and accelerator fabrication in order to measure electron clouds and mitigate the adverse effects of such clouds on beam propagation.

  1. Draft of diagnostic techniques for primary coolant circuit facilities using control computer

    International Nuclear Information System (INIS)

    Suchy, R.; Procka, V.; Murin, V.; Rybarova, D.

    A method is proposed of in-service on-line diagnostics of primary circuit selected parts by means of a control computer. Computer processing will involve the measurements of neutron flux, pressure difference in pumps and in the core, and the vibrations of primary circuit mechanical parts. (H.S.)

  2. 16th International Conference on Medical Image Computing and Computer Assisted Intervention

    CERN Document Server

    Klinder, Tobias; Li, Shuo

    2014-01-01

    This book contains the full papers presented at the MICCAI 2013 workshop Computational Methods and Clinical Applications for Spine Imaging. The workshop brought together researchers representing several fields, such as Biomechanics, Engineering, Medicine, Mathematics, Physics and Statistic. The works included in this book present and discuss new trends in those fields, using several methods and techniques in order to address more efficiently different and timely applications involving signal and image acquisition, image processing and analysis, image segmentation, image registration and fusion, computer simulation, image based modelling, simulation and surgical planning, image guided robot assisted surgical and image based diagnosis.

  3. Two-Cloud-Servers-Assisted Secure Outsourcing Multiparty Computation

    Science.gov (United States)

    Wen, Qiaoyan; Zhang, Hua; Jin, Zhengping; Li, Wenmin

    2014-01-01

    We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users' public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function. PMID:24982949

  4. Two-cloud-servers-assisted secure outsourcing multiparty computation.

    Science.gov (United States)

    Sun, Yi; Wen, Qiaoyan; Zhang, Yudong; Zhang, Hua; Jin, Zhengping; Li, Wenmin

    2014-01-01

    We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users' public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function.

  5. Computer-assisted mammography in clinical practice: Another set of problems to solve

    International Nuclear Information System (INIS)

    Gale, A.G.; Roebuck, E.J.; Worthington, B.S.

    1986-01-01

    To be adopted in radiological practice, computer-assisted diagnosis must address a domain of realistic complexity and have a high performance in terms of speed and reliability. Use of a microcomputer-based system of mammographic diagnoses employing discriminant function analysis resulted in significantly fewer false-positive diagnoses while producing a similar level of correct diagnoses of cancer as normal reporting. Although such a system is a valuable teaching aid, its clinical use is constrained by the problems of unambiguously codifying descriptors, data entry time, and the tendency of radiologists to override predicted diagnoses which conflict with their own

  6. A Diagnostic Model for Dementia in Clinical Practice-Case Methodology Assisting Dementia Diagnosis.

    Science.gov (United States)

    Londos, Elisabet

    2015-04-02

    Dementia diagnosis is important for many different reasons. Firstly, to separate dementia, or major neurocognitive disorder, from MCI (mild cognitive impairment), mild neurocognitive disorder. Secondly, to define the specific underlying brain disorder to aid treatment, prognosis and decisions regarding care needs and assistance. The diagnostic method of dementias is a puzzle of different data pieces to be fitted together in the best possible way to reach a clinical diagnosis. Using a modified case methodology concept, risk factors affecting cognitive reserve and symptoms constituting the basis of the brain damage hypothesis, can be visualized, balanced and reflected against test results as well as structural and biochemical markers. The model's origin is the case method initially described in Harvard business school, here modified to serve dementia diagnostics.

  7. Validation of a novel computer-assisted sperm analysis (CASA) system using multitarget-tracking algorithms.

    Science.gov (United States)

    Tomlinson, Mathew James; Pooley, Karen; Simpson, Tracey; Newton, Thomas; Hopkisson, James; Jayaprakasan, Kannamanadias; Jayaprakasan, Rajisha; Naeem, Asad; Pridmore, Tony

    2010-04-01

    To determine the accuracy and precision of a novel computer-assisted sperm analysis (CASA) system by comparison with existing recommended manual methods. Prospective study using comparative measurements of sperm concentration and motility on latex beads and immotile and motile sperm. Tertiary referral fertility center with strong academic links. Sperm donors and male partners of couples attending for fertility investigations. None. Achievement of Accubead target value for high and low concentration suspensions. Repeatability as demonstrated by coefficients of variation and intraclass correlation coefficients. Correlation and limits of agreement between CASA and manual methods. The CASA measurements of latex beads and sperm concentrations demonstrated a high level of accuracy and repeatability. Repeated Accubead measurements attained the required target value (mean difference from target of 2.61% and 3.71% for high- and low-concentration suspensions, respectively) and were highly reproducible. Limits of agreement analysis suggested that manual and CASA counts compared directly could be deemed to be interchangeable. Manual and CASA motility measurements were highly correlated for grades a, b, and d but could not be deemed to be interchangeable, and manual motility estimates were consistently higher for motile sperm. The novel CASA system was able to provide semen quality measurements for sperm concentration and motility measurements which were at least as reliable as current manual methods. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  8. Computer-assisted diagnostic tool to quantify the pulmonary veins in sickle cell associated pulmonary hypertension

    Science.gov (United States)

    Jajamovich, Guido H.; Pamulapati, Vivek; Alam, Shoaib; Mehari, Alem; Kato, Gregory J.; Wood, Bradford J.; Linguraru, Marius George

    2012-03-01

    Pulmonary hypertension is a common cause of death among patients with sickle cell disease. This study investigates the use of pulmonary vein analysis to assist the diagnosis of pulmonary hypertension non-invasively with CT-Angiography images. The characterization of the pulmonary veins from CT presents two main challenges. Firstly, the number of pulmonary veins is unknown a priori and secondly, the contrast material is degraded when reaching the pulmonary veins, making the edges of these vessels to appear faint. Each image is first denoised and a fast marching approach is used to segment the left atrium and pulmonary veins. Afterward, a geodesic active contour is employed to isolate the left atrium. A thinning technique is then used to extract the skeleton of the atrium and the veins. The locations of the pulmonary veins ostia are determined by the intersection of the skeleton and the contour of the atrium. The diameters of the pulmonary veins are measured in each vein at fixed distances from the corresponding ostium, and for each distance, the sum of the diameters of all the veins is computed. These indicators are shown to be significantly larger in sickle-cell patients with pulmonary hypertension as compared to controls (p-values < 0.01).

  9. Thioaptamer Diagnostic System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — AM Biotechnologies (AM) will develop a diagnostic system in response to SBIR Topic X10.01 Reusable Diagnostic Lab Technology that will simultaneously detect and...

  10. Computer-assisted sperm analysis (CASA): capabilities and potential developments.

    Science.gov (United States)

    Amann, Rupert P; Waberski, Dagmar

    2014-01-01

    Computer-assisted sperm analysis (CASA) systems have evolved over approximately 40 years, through advances in devices to capture the image from a microscope, huge increases in computational power concurrent with amazing reduction in size of computers, new computer languages, and updated/expanded software algorithms. Remarkably, basic concepts for identifying sperm and their motion patterns are little changed. Older and slower systems remain in use. Most major spermatology laboratories and semen processing facilities have a CASA system, but the extent of reliance thereon ranges widely. This review describes capabilities and limitations of present CASA technology used with boar, bull, and stallion sperm, followed by possible future developments. Each marketed system is different. Modern CASA systems can automatically view multiple fields in a shallow specimen chamber to capture strobe-like images of 500 to >2000 sperm, at 50 or 60 frames per second, in clear or complex extenders, and in information for ≥ 30 frames and provide summary data for each spermatozoon and the population. A few systems evaluate sperm morphology concurrent with motion. CASA cannot accurately predict 'fertility' that will be obtained with a semen sample or subject. However, when carefully validated, current CASA systems provide information important for quality assurance of semen planned for marketing, and for the understanding of the diversity of sperm responses to changes in the microenvironment in research. The four take-home messages from this review are: (1) animal species, extender or medium, specimen chamber, intensity of illumination, imaging hardware and software, instrument settings, technician, etc., all affect accuracy and precision of output values; (2) semen production facilities probably do not need a substantially different CASA system whereas biology laboratories would benefit from systems capable of imaging and tracking sperm in deep chambers for a flexible period of time

  11. Effectiveness of Computer-Assisted Mathematics Education (CAME) over Academic Achievement: A Meta-Analysis Study

    Science.gov (United States)

    Demir, Seda; Basol, Gülsah

    2014-01-01

    The aim of the current study is to determine the overall effects of Computer-Assisted Mathematics Education (CAME) on academic achievement. After an extensive review of the literature, studies using Turkish samples and observing the effects of Computer-Assisted Education (CAE) on mathematics achievement were examined. As a result of this…

  12. 45 CFR 233.34 - Computing the assistance payment in the initial one or two months (AFDC).

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Computing the assistance payment in the initial... § 233.34 Computing the assistance payment in the initial one or two months (AFDC). A State shall compute...) If the initial month is computed prospectively as in paragraph (a) of this section, the second month...

  13. An intercomparison of computer assisted date processing and display methods in radioisotope scintigraphy using mathematical tumours

    International Nuclear Information System (INIS)

    Houston, A.S.; Macleod, M.A.

    1977-01-01

    Several computer assisted processing and display methods are evaluated using a series of 100 normal brain scintigrams, 50 of which have had single 'mathematical tumours' superimposed. Using a standard rating system, or in some cases quantitative estimation, LROC curves are generated for each method and compared. (author)

  14. Diagnostic systems in nuclear power plants. Proceedings of a technical committee meeting. Working material

    International Nuclear Information System (INIS)

    1998-01-01

    Nuclear power industry has a quite long tradition in on-line diagnostic of mechanical components and a considerable effort was put in developing diagnostic systems which are able to detect arising mechanical problems at an early stage. Computers are increasingly exploited to provide higher level information on process behaviour such as: early indication of the process deviation from normal conditions; rapid identification of the cause of any disturbance; prediction of the evolution of a disturbance; operator aid through computerized help. Following the recommendation of Several Member States to strengthen the activity in this field two divisions of IAEA established in 1995 the International Task Force on Nuclear Power Plant Diagnostics. The scope of the task force cover both technological developments and safety/licensing aspects of diagnostics. This report contains papers presented at the last in the series of Technical Committee Meetings on the Diagnostic Systems in Nuclear Power Plants organized in the framework of International Task Force

  15. Diagnostic systems in nuclear power plants. Proceedings of a technical committee meeting. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-31

    Nuclear power industry has a quite long tradition in on-line diagnostic of mechanical components and a considerable effort was put in developing diagnostic systems which are able to detect arising mechanical problems at an early stage. Computers are increasingly exploited to provide higher level information on process behaviour such as: early indication of the process deviation from normal conditions; rapid identification of the cause of any disturbance; prediction of the evolution of a disturbance; operator aid through computerized help. Following the recommendation of Several Member States to strengthen the activity in this field two divisions of IAEA established in 1995 the International Task Force on Nuclear Power Plant Diagnostics. The scope of the task force cover both technological developments and safety/licensing aspects of diagnostics. This report contains papers presented at the last in the series of Technical Committee Meetings on the Diagnostic Systems in Nuclear Power Plants organized in the framework of International Task Force Refs, figs, tabs

  16. Computized analysis of diagnostic level in breast diseases and frequency of their clinicoroentgenological symptoms

    International Nuclear Information System (INIS)

    Babij, Ya.S.; Krakhmaleva, L.P.; Shumakov, A.G.

    1988-01-01

    A standardized chart with a list of clinicoroentgenological symptoms of the most frequent mammary gland diseases is developed. The data of computer analysis of the diagnostics level and the frequency of clinicoroentgenological symptoms of different diseases of the mammary gland are given. The data obtained can be used for conventional and computer diagnostics of mammary gland diseases, as well as as a basis for the further study of semiotics of different pathological processes in the mammary gland. 22 refs

  17. Biomedical visual data analysis to build an intelligent diagnostic decision support system in medical genetics.

    Science.gov (United States)

    Kuru, Kaya; Niranjan, Mahesan; Tunca, Yusuf; Osvank, Erhan; Azim, Tayyaba

    2014-10-01

    In general, medical geneticists aim to pre-diagnose underlying syndromes based on facial features before performing cytological or molecular analyses where a genotype-phenotype interrelation is possible. However, determining correct genotype-phenotype interrelationships among many syndromes is tedious and labor-intensive, especially for extremely rare syndromes. Thus, a computer-aided system for pre-diagnosis can facilitate effective and efficient decision support, particularly when few similar cases are available, or in remote rural districts where diagnostic knowledge of syndromes is not readily available. The proposed methodology, visual diagnostic decision support system (visual diagnostic DSS), employs machine learning (ML) algorithms and digital image processing techniques in a hybrid approach for automated diagnosis in medical genetics. This approach uses facial features in reference images of disorders to identify visual genotype-phenotype interrelationships. Our statistical method describes facial image data as principal component features and diagnoses syndromes using these features. The proposed system was trained using a real dataset of previously published face images of subjects with syndromes, which provided accurate diagnostic information. The method was tested using a leave-one-out cross-validation scheme with 15 different syndromes, each of comprised 5-9 cases, i.e., 92 cases in total. An accuracy rate of 83% was achieved using this automated diagnosis technique, which was statistically significant (pbenefits of using hybrid image processing and ML-based computer-aided diagnostics for identifying facial phenotypes. Copyright © 2014. Published by Elsevier B.V.

  18. The introduction, deployment and impact of assistant practitioners in diagnostic radiography in Scotland

    International Nuclear Information System (INIS)

    Price, R.; Miller, L.; Hicks, B.; Higgs, A.

    2015-01-01

    This article describes the outcomes of an evaluation of the impact of introducing Assistant Practitioners (AP) roles into imaging departments in 13 of the 14 NHS Boards in Scotland. Between 2006 and 2009 some 34 individuals were trained as APs in diagnostic radiography with 33 subsequently taking up AP posts. In 2010 NHS Education for Scotland commissioned an evaluation of the impact brought about through introduction of the diagnostic imaging AP role in imaging departments. The research found that a minority of the managers had considered the workforce implications of introducing the new roles or the supervisory arrangements that would be required. In some sites implementation of the roles had resulted in the release of radiographers for additional training and higher level activities, but in others financial constraints had limited such initiatives. Managers believed that APs had helped maintain or improve service capacity and quality. - Highlights: • Minority of managers consider implications of new roles or supervisory arrangements. • Assistant practitioners (APs) help maintain or improve service capacity and quality. • Financial constraints limit training and initiatives. • APs can allow staff release for training and work in specialist modalities. • Data collection key in measuring financial effectiveness, capacity and impact

  19. Diagnostic and monitoring systems produced in Vuje, Okruzna 5, 918 64 Trnava, Slovak Republic

    International Nuclear Information System (INIS)

    Oksa, G.; Bahna, J.; Murin, V.; Kucharek, P.; Smutny, S.

    1996-01-01

    Based on the 20 years experience in on-line vibration diagnostics of mechanical components in the primary circuit of nuclear power plant PWR WWER-440, Vuje, Okruzna 5, 918 64 Trnava produces its own diagnostic and monitoring systems since 1990. The variety of diagnostic systems includes: loose part monitoring system (LPMS), monitoring system of main circulating pumps (MCPMS), vibration monitoring system (LVMS), leakage monitoring system (LMS). The emphasis in the hardware solution is put on the design modularity and versatility so that many subcomponents (circuit boards) are common or highly similar for all systems. Using exclusively digital data for processing enhances the reliability of the measurements and allows the easy data transportation from one computer to another (e.g., for more sophisticated analysis). Trends in the software development follow the similar path as for the hardware solution - namely, the modularity and versatility of software is the imperative goal. The modern operating systems also incorporate the ability of network communication, which is crucial for the integration of stand-alone diagnostic systems into nuclear power plants information system. So far a number of systems have been successfully installed: 6 LPMSs (Jaslovske Bohunice, Dukovany), 4 MCPMs (Jaslovske Bohunice) and 2 LVMSs (Jaslovske Bohunice), all systems operate in PWR WWER-440 environment. Another diagnostic systems are under construction: 2 LPMSs (Temelin, PWR WWER-1000), 2 MCMSs (Mochovce - PWR WWER-440) and 2 LMSs (Jaslovske Bohunice). (author). 1 fig

  20. Diagnostic and monitoring systems produced in Vuje, Okruzna 5, 918 64 Trnava, Slovak Republic

    Energy Technology Data Exchange (ETDEWEB)

    Oksa, G; Bahna, J; Murin, V; Kucharek, P; Smutny, S [Vyskumny Ustav Jadrovych Elektrarni, Trnava (Slovakia)

    1997-12-31

    Based on the 20 years experience in on-line vibration diagnostics of mechanical components in the primary circuit of nuclear power plant PWR WWER-440, Vuje, Okruzna 5, 918 64 Trnava produces its own diagnostic and monitoring systems since 1990. The variety of diagnostic systems includes: loose part monitoring system (LPMS), monitoring system of main circulating pumps (MCPMS), vibration monitoring system (LVMS), leakage monitoring system (LMS). The emphasis in the hardware solution is put on the design modularity and versatility so that many subcomponents (circuit boards) are common or highly similar for all systems. Using exclusively digital data for processing enhances the reliability of the measurements and allows the easy data transportation from one computer to another (e.g., for more sophisticated analysis). Trends in the software development follow the similar path as for the hardware solution - namely, the modularity and versatility of software is the imperative goal. The modern operating systems also incorporate the ability of network communication, which is crucial for the integration of stand-alone diagnostic systems into nuclear power plants information system. So far a number of systems have been successfully installed: 6 LPMSs (Jaslovske Bohunice, Dukovany), 4 MCPMs (Jaslovske Bohunice) and 2 LVMSs (Jaslovske Bohunice), all systems operate in PWR WWER-440 environment. Another diagnostic systems are under construction: 2 LPMSs (Temelin, PWR WWER-1000), 2 MCMSs (Mochovce - PWR WWER-440) and 2 LMSs (Jaslovske Bohunice). (author). 1 fig.

  1. Potential of Cognitive Computing and Cognitive Systems

    Science.gov (United States)

    Noor, Ahmed K.

    2015-01-01

    Cognitive computing and cognitive technologies are game changers for future engineering systems, as well as for engineering practice and training. They are major drivers for knowledge automation work, and the creation of cognitive products with higher levels of intelligence than current smart products. This paper gives a brief review of cognitive computing and some of the cognitive engineering systems activities. The potential of cognitive technologies is outlined, along with a brief description of future cognitive environments, incorporating cognitive assistants - specialized proactive intelligent software agents designed to follow and interact with humans and other cognitive assistants across the environments. The cognitive assistants engage, individually or collectively, with humans through a combination of adaptive multimodal interfaces, and advanced visualization and navigation techniques. The realization of future cognitive environments requires the development of a cognitive innovation ecosystem for the engineering workforce. The continuously expanding major components of the ecosystem include integrated knowledge discovery and exploitation facilities (incorporating predictive and prescriptive big data analytics); novel cognitive modeling and visual simulation facilities; cognitive multimodal interfaces; and cognitive mobile and wearable devices. The ecosystem will provide timely, engaging, personalized / collaborative, learning and effective decision making. It will stimulate creativity and innovation, and prepare the participants to work in future cognitive enterprises and develop new cognitive products of increasing complexity. http://www.aee.odu.edu/cognitivecomp

  2. Applications of NLP Techniques to Computer-Assisted Authoring of Test Items for Elementary Chinese

    Science.gov (United States)

    Liu, Chao-Lin; Lin, Jen-Hsiang; Wang, Yu-Chun

    2010-01-01

    The authors report an implemented environment for computer-assisted authoring of test items and provide a brief discussion about the applications of NLP techniques for computer assisted language learning. Test items can serve as a tool for language learners to examine their competence in the target language. The authors apply techniques for…

  3. User-assisted video segmentation system for visual communication

    Science.gov (United States)

    Wu, Zhengping; Chen, Chun

    2002-01-01

    Video segmentation plays an important role for efficient storage and transmission in visual communication. In this paper, we introduce a novel video segmentation system using point tracking and contour formation techniques. Inspired by the results from the study of the human visual system, we intend to solve the video segmentation problem into three separate phases: user-assisted feature points selection, feature points' automatic tracking, and contour formation. This splitting relieves the computer of ill-posed automatic segmentation problems, and allows a higher level of flexibility of the method. First, the precise feature points can be found using a combination of user assistance and an eigenvalue-based adjustment. Second, the feature points in the remaining frames are obtained using motion estimation and point refinement. At last, contour formation is used to extract the object, and plus a point insertion process to provide the feature points for next frame's tracking.

  4. [Clinical analysis of 12 cases of orthognathic surgery with digital computer-assisted technique].

    Science.gov (United States)

    Tan, Xin-ying; Hu, Min; Liu, Chang-kui; Liu, Hua-wei; Liu, San-xia; Tao, Ye

    2014-06-01

    This study was to investigate the effect of the digital computer-assisted technique in orthognathic surgery. Twelve patients from January 2008 to December 2011 with jaw malformation were treated in our department. With the help of CT and three-dimensional reconstruction technique, 12 patients underwent surgical treatment and the results were evaluated after surgery. Digital computer-assisted technique could clearly show the status of the jaw deformity and assist virtual surgery. After surgery all patients were satisfied with the results. Digital orthognathic surgery can improve the predictability of the surgical procedure, and to facilitate patients' communication, shorten operative time, and reduce patients' pain.

  5. [CONE BEAM COMPUTED TOMOGRAPHY IN DIAGNOSTICS OF ODONTOGENIC MAXILLARY SINUSITIS (CASE REPORTS)].

    Science.gov (United States)

    Demidova, E; Khurdzidze, G

    2017-06-01

    Diagnostic studies performed by cone beam computed tomography Morita 3D made possible to obtain high resolution images of hard tissues of upper jawbone and maxillary sinus, to detect bony tissue defects, such as odontogenic cysts, cystogranulomas and granulomas. High-resolution and three dimensional tomographic image reconstructions allowed for optimal and prompt determination of the scope of surgical treatment and planning of effective conservative treatment regimen. Interactive diagnostics helped to estimate cosmetic and functional results of surgical treatment, to prevent the occurrence of surgical complications, and to evaluate the efficacy of conservative treatment. The obtained data contributed to determination of particular applications of cone beam computed tomography in the diagnosis of odontogenic maxillary sinusitis, detection of specific defects with cone beam tomography as the most informative method of diagnosis; as well as to determination of weak and strong sides, and helped to offer mechanisms of x-ray diagnostics to dental surgeons and ENT specialists.

  6. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  7. Integrating Computer-Assisted Language Learning in Saudi Schools: A Change Model

    Science.gov (United States)

    Alresheed, Saleh; Leask, Marilyn; Raiker, Andrea

    2015-01-01

    Computer-assisted language learning (CALL) technology and pedagogy have gained recognition globally for their success in supporting second language acquisition (SLA). In Saudi Arabia, the government aims to provide most educational institutions with computers and networking for integrating CALL into classrooms. However, the recognition of CALL's…

  8. Computer program user's manual for FIREFINDER digital topographic data verification library dubbing system

    Science.gov (United States)

    Ceres, M.; Heselton, L. R., III

    1981-11-01

    This manual describes the computer programs for the FIREFINDER Digital Topographic Data Verification-Library-Dubbing System (FFDTDVLDS), and will assist in the maintenance of these programs. The manual contains detailed flow diagrams and associated descriptions for each computer program routine and subroutine. Complete computer program listings are also included. This information should be used when changes are made in the computer programs. The operating system has been designed to minimize operator intervention.

  9. Solar-assisted heat pump system for cost-effective space heating and cooling

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J W; Kush, E A; Metz, P D

    1978-03-01

    The use of heat pumps for the utilization of solar energy is studied. Two requirements for a cost-effective system are identified: (1) a special heat pump whose coefficient of performance continues to rise with source temperature over the entire range appropriate for solar assist, and (2) a low-cost collection and storage subsystem able to supply solar energy to the heat pump efficiently at low temperatures. Programs leading to the development of these components are discussed. A solar assisted heat pump system using these components is simulated via a computer, and the results of the simulation are used as the basis for a cost comparison of the proposed system with other solar and conventional systems.

  10. Center for Advanced Energy Studies: Computer Assisted Virtual Environment (CAVE)

    Data.gov (United States)

    Federal Laboratory Consortium — The laboratory contains a four-walled 3D computer assisted virtual environment - or CAVE TM — that allows scientists and engineers to literally walk into their data...

  11. Mechatronics Interface for Computer Assisted Prostate Surgery Training

    Science.gov (United States)

    Altamirano del Monte, Felipe; Padilla Castañeda, Miguel A.; Arámbula Cosío, Fernando

    2006-09-01

    In this work is presented the development of a mechatronics device to simulate the interaction of the surgeon with the surgical instrument (resectoscope) used during a Transurethral Resection of the Prostate (TURP). Our mechatronics interface is part of a computer assisted system for training in TURP, which is based on a 3D graphics model of the prostate which can be deformed and resected interactively by the user. The mechatronics interface, is the device that the urology residents will manipulate to simulate the movements performed during surgery. Our current prototype has five degrees of freedom, which are enough to have a realistic simulation of the surgery movements. Two of these degrees of freedom are linear, to determinate the linear displacement of the resecting loop and the other three are rotational to determinate three directions and amounts of rotation.

  12. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    Science.gov (United States)

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  13. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.

    Science.gov (United States)

    Huang, Qinghua; Zhang, Fan; Li, Xuelong

    2018-01-01

    The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  14. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    Directory of Open Access Journals (Sweden)

    Qinghua Huang

    2018-01-01

    Full Text Available The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  15. Mid-term survival analysis of closed wedge high tibial osteotomy: A comparative study of computer-assisted and conventional techniques.

    Science.gov (United States)

    Bae, Dae Kyung; Song, Sang Jun; Kim, Kang Il; Hur, Dong; Jeong, Ho Yeon

    2016-03-01

    The purpose of the present study was to compare the clinical and radiographic results and survival rates between computer-assisted and conventional closing wedge high tibial osteotomies (HTOs). Data from a consecutive cohort comprised of 75 computer-assisted HTOs and 75 conventional HTOs were retrospectively reviewed. The Knee Society knee and function scores, Hospital for Special Surgery (HSS) score and femorotibial angle (FTA) were compared between the two groups. Survival rates were also compared with procedure failure. The knee and function scores at one year postoperatively were slightly better in the computer-assisted group than those in conventional group (90.1 vs. 86.1) (82.0 vs. 76.0). The HSS scores at one year postoperatively were slightly better for the computer-assisted HTOs than those of conventional HTOs (89.5 vs. 81.8). The inlier of the postoperative FTA was wider in the computer-assisted group than that in the conventional HTO group (88.0% vs. 58.7%), and mean postoperative FTA was greater in the computer-assisted group that in the conventional HTO group (valgus 9.0° vs. valgus 7.6°, pclinical and radiographic results were better in the computer-assisted group that those in the conventional HTO group. Mid-term survival rates did not differ between computer-assisted and conventional HTOs. A comparative analysis of longer-term survival rate is required to demonstrate the long-term benefit of computer-assisted HTO. III. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Computer-Assisted Language Learning (CALL) in Support of (Re)-Learning Native Languages: The Case of Runyakitara

    Science.gov (United States)

    Katushemererwe, Fridah; Nerbonne, John

    2015-01-01

    This study presents the results from a computer-assisted language learning (CALL) system of Runyakitara (RU_CALL). The major objective was to provide an electronic language learning environment that can enable learners with mother tongue deficiencies to enhance their knowledge of grammar and acquire writing skills in Runyakitara. The system…

  17. Computer-Assisted, Counselor-Delivered Smoking Cessation Counseling for Community College Students: Intervention Approach and Sample Characteristics

    Science.gov (United States)

    Prokhorov, Alexander V.; Fouladi, Rachel T.; de Moor, Carl; Warneke, Carla L.; Luca, Mario; Jones, Mary Mullin; Rosenblum, Carol; Emmons, Karen M.; Hudmon, Karen Suchanek; Yost, Tracey E.; Gritz, Ellen R.

    2007-01-01

    This report presents the experimental approach and baseline findings from "Look at Your Health," an ongoing study to develop and evaluate a computer-assisted, counselor-delivered smoking cessation program for community college students. It describes the expert system software program used for data collection and for provision of tailored feedback,…

  18. Two-Cloud-Servers-Assisted Secure Outsourcing Multiparty Computation

    Directory of Open Access Journals (Sweden)

    Yi Sun

    2014-01-01

    Full Text Available We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users’ public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function.

  19. Case-Based Fault Diagnostic System

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2014-01-01

    Nowadays, case-based fault diagnostic (CBFD) systems have become important and widely applied problem solving technologies. They are based on the assumption that “similar faults have similar diagnosis”. On the other hand, CBFD systems still suffer from some limitations. Common ones of them are: (1) failure of CBFD to have the needed diagnosis for the new faults that have no similar cases in the case library. (2) Limited memorization when increasing the number of stored cases in the library. The proposed research introduces incorporating the neural network into the case based system to enable the system to diagnose all the faults. Neural networks have proved their success in the classification and diagnosis problems. The suggested system uses the neural network to diagnose the new faults (cases) that cannot be diagnosed by the traditional CBR diagnostic system. Besides, the proposed system can use the another neural network to control adding and deleting the cases in the library to manage the size of the cases in the case library. However, the suggested system has improved the performance of the case based fault diagnostic system when applied for the motor rolling bearing as a case of study

  20. The Information Science Experiment System - The computer for science experiments in space

    Science.gov (United States)

    Foudriat, Edwin C.; Husson, Charles

    1989-01-01

    The concept of the Information Science Experiment System (ISES), potential experiments, and system requirements are reviewed. The ISES is conceived as a computer resource in space whose aim is to assist computer, earth, and space science experiments, to develop and demonstrate new information processing concepts, and to provide an experiment base for developing new information technology for use in space systems. The discussion covers system hardware and architecture, operating system software, the user interface, and the ground communication link.

  1. Computer-Assisted Foreign Language Teaching and Learning: Technological Advances

    Science.gov (United States)

    Zou, Bin; Xing, Minjie; Wang, Yuping; Sun, Mingyu; Xiang, Catherine H.

    2013-01-01

    Computer-Assisted Foreign Language Teaching and Learning: Technological Advances highlights new research and an original framework that brings together foreign language teaching, experiments and testing practices that utilize the most recent and widely used e-learning resources. This comprehensive collection of research will offer linguistic…

  2. The Effects of Computer-Assisted Feedback Strategies in Technology Education: A Comparison of Learning Outcomes

    Science.gov (United States)

    Adams, Ruifang Hope; Strickland, Jane

    2012-01-01

    This study investigated the effects of computer-assisted feedback strategies that have been utilized by university students in a technology education curriculum. Specifically, the study examined the effectiveness of the computer-assisted feedback strategy "Knowledge of Response feedback" (KOR), and the "Knowledge of Correct Responses feedback"…

  3. Computer-assisted spectral design and synthesis

    Science.gov (United States)

    Vadakkumpadan, Fijoy; Wang, Qiqi; Sun, Yinlong

    2005-01-01

    In this paper, we propose a computer-assisted approach for spectral design and synthesis. This approach starts with some initial spectrum, modifies it interactively, evaluates the change, and decides the optimal spectrum. Given a requested change as function of wavelength, we model the change function using a Gaussian function. When there is the metameric constraint, from the Gaussian function of request change, we propose a method to generate the change function such that the result spectrum has the same color as the initial spectrum. We have tested the proposed method with different initial spectra and change functions, and implemented an interactive graphics environment for spectral design and synthesis. The proposed approach and graphics implementation for spectral design and synthesis can be helpful for a number of applications such as lighting of building interiors, textile coloration, and pigment development of automobile paints, and spectral computer graphics.

  4. FRIEND: a brain-monitoring agent for adaptive and assistive systems.

    Science.gov (United States)

    Morris, Alexis; Ulieru, Mihaela

    2012-01-01

    This paper presents an architectural design for adaptive-systems agents (FRIEND) that use brain state information to make more effective decisions on behalf of a user; measuring brain context versus situational demands. These systems could be useful for alerting users to cognitive workload levels or fatigue, and could attempt to compensate for higher cognitive activity by filtering noise information. In some cases such systems could also share control of devices, such as pulling over in an automated vehicle. These aim to assist people in everyday systems to perform tasks better and be more aware of internal states. Achieving a functioning system of this sort is a challenge, involving a unification of brain- computer-interfaces, human-computer-interaction, soft-computin deliberative multi-agent systems disciplines. Until recently, these were not able to be combined into a usable platform due largely to technological limitations (e.g., size, cost, and processing speed), insufficient research on extracting behavioral states from EEG signals, and lack of low-cost wireless sensing headsets. We aim to surpass these limitations and develop control architectures for making sense of brain state in applications by realizing an agent architecture for adaptive (human-aware) technology. In this paper we present an early, high-level design towards implementing a multi-purpose brain-monitoring agent system to improve user quality of life through the assistive applications of psycho-physiological monitoring, noise-filtering, and shared system control.

  5. Three-Dimensional Computer-Assisted Two-Layer Elastic Models of the Face.

    Science.gov (United States)

    Ueda, Koichi; Shigemura, Yuka; Otsuki, Yuki; Fuse, Asuka; Mitsuno, Daisuke

    2017-11-01

    To make three-dimensional computer-assisted elastic models for the face, we decided on five requirements: (1) an elastic texture like skin and subcutaneous tissue; (2) the ability to take pen marking for incisions; (3) the ability to be cut with a surgical knife; (4) the ability to keep stitches in place for a long time; and (5) a layered structure. After testing many elastic solvents, we have made realistic three-dimensional computer-assisted two-layer elastic models of the face and cleft lip from the computed tomographic and magnetic resonance imaging stereolithographic data. The surface layer is made of polyurethane and the inner layer is silicone. Using this elastic model, we taught residents and young doctors how to make several typical local flaps and to perform cheiloplasty. They could experience realistic simulated surgery and understand three-dimensional movement of the flaps.

  6. Computer-based route-definition system for peripheral bronchoscopy.

    Science.gov (United States)

    Graham, Michael W; Gibbs, Jason D; Higgins, William E

    2012-04-01

    Multi-detector computed tomography (MDCT) scanners produce high-resolution images of the chest. Given a patient's MDCT scan, a physician can use an image-guided intervention system to first plan and later perform bronchoscopy to diagnostic sites situated deep in the lung periphery. An accurate definition of complete routes through the airway tree leading to the diagnostic sites, however, is vital for avoiding navigation errors during image-guided bronchoscopy. We present a system for the robust definition of complete airway routes suitable for image-guided bronchoscopy. The system incorporates both automatic and semiautomatic MDCT analysis methods for this purpose. Using an intuitive graphical user interface, the user invokes automatic analysis on a patient's MDCT scan to produce a series of preliminary routes. Next, the user visually inspects each route and quickly corrects the observed route defects using the built-in semiautomatic methods. Application of the system to a human study for the planning and guidance of peripheral bronchoscopy demonstrates the efficacy of the system.

  7. Psychometric perspectives on diagnostic systems

    NARCIS (Netherlands)

    Borsboom, D.

    2008-01-01

    The author identifies four conceptualizations of the relation between symptoms and disorders as utilized in diagnostic systems such as the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV; American Psychiatric Association, 1994): A constructivist perspective, which holds

  8. Efficient Probabilistic Diagnostics for Electrical Power Systems

    Science.gov (United States)

    Mengshoel, Ole J.; Chavira, Mark; Cascio, Keith; Poll, Scott; Darwiche, Adnan; Uckun, Serdar

    2008-01-01

    We consider in this work the probabilistic approach to model-based diagnosis when applied to electrical power systems (EPSs). Our probabilistic approach is formally well-founded, as it based on Bayesian networks and arithmetic circuits. We investigate the diagnostic task known as fault isolation, and pay special attention to meeting two of the main challenges . model development and real-time reasoning . often associated with real-world application of model-based diagnosis technologies. To address the challenge of model development, we develop a systematic approach to representing electrical power systems as Bayesian networks, supported by an easy-to-use speci.cation language. To address the real-time reasoning challenge, we compile Bayesian networks into arithmetic circuits. Arithmetic circuit evaluation supports real-time diagnosis by being predictable and fast. In essence, we introduce a high-level EPS speci.cation language from which Bayesian networks that can diagnose multiple simultaneous failures are auto-generated, and we illustrate the feasibility of using arithmetic circuits, compiled from Bayesian networks, for real-time diagnosis on real-world EPSs of interest to NASA. The experimental system is a real-world EPS, namely the Advanced Diagnostic and Prognostic Testbed (ADAPT) located at the NASA Ames Research Center. In experiments with the ADAPT Bayesian network, which currently contains 503 discrete nodes and 579 edges, we .nd high diagnostic accuracy in scenarios where one to three faults, both in components and sensors, were inserted. The time taken to compute the most probable explanation using arithmetic circuits has a small mean of 0.2625 milliseconds and standard deviation of 0.2028 milliseconds. In experiments with data from ADAPT we also show that arithmetic circuit evaluation substantially outperforms joint tree propagation and variable elimination, two alternative algorithms for diagnosis using Bayesian network inference.

  9. A malaria diagnostic tool based on computer vision screening and visualization of Plasmodium falciparum candidate areas in digitized blood smears.

    Directory of Open Access Journals (Sweden)

    Nina Linder

    Full Text Available INTRODUCTION: Microscopy is the gold standard for diagnosis of malaria, however, manual evaluation of blood films is highly dependent on skilled personnel in a time-consuming, error-prone and repetitive process. In this study we propose a method using computer vision detection and visualization of only the diagnostically most relevant sample regions in digitized blood smears. METHODS: Giemsa-stained thin blood films with P. falciparum ring-stage trophozoites (n = 27 and uninfected controls (n = 20 were digitally scanned with an oil immersion objective (0.1 µm/pixel to capture approximately 50,000 erythrocytes per sample. Parasite candidate regions were identified based on color and object size, followed by extraction of image features (local binary patterns, local contrast and Scale-invariant feature transform descriptors used as input to a support vector machine classifier. The classifier was trained on digital slides from ten patients and validated on six samples. RESULTS: The diagnostic accuracy was tested on 31 samples (19 infected and 12 controls. From each digitized area of a blood smear, a panel with the 128 most probable parasite candidate regions was generated. Two expert microscopists were asked to visually inspect the panel on a tablet computer and to judge whether the patient was infected with P. falciparum. The method achieved a diagnostic sensitivity and specificity of 95% and 100% as well as 90% and 100% for the two readers respectively using the diagnostic tool. Parasitemia was separately calculated by the automated system and the correlation coefficient between manual and automated parasitemia counts was 0.97. CONCLUSION: We developed a decision support system for detecting malaria parasites using a computer vision algorithm combined with visualization of sample areas with the highest probability of malaria infection. The system provides a novel method for blood smear screening with a significantly reduced need for

  10. Parametric sensitivity study for solar-assisted heat-pump systems

    Science.gov (United States)

    White, N. M.; Morehouse, J. H.

    1981-07-01

    The engineering and economic parameters affecting life-cycle costs for solar-assisted heat pump systems are investigted. The change in energy usage resulting from each engineering parameter varied was developed from computer simulations, and is compared with results from a stand-alone heat pump system. Three geographical locations are considered: Washington, DC, Fort Worth, TX, and Madison, WI. Results indicate that most engineering changes to the systems studied do not provide significant energy savings. The most promising parameters to ary are the solar collector parameters tau (-) and U/sub L/ the heat pump capacity at design point, and the minimum utilizable evaporator temperature. Costs associated with each change are estimated, and life-cycle costs computed for both engineering parameters and economic variations in interest rate, discount rate, tax credits, fuel unit costs and fuel inflation rates. Results indicate that none of the feasibile engineering changes for the system configuration studied will make these systems economically competitive with the stand-alone heat pump without a considerable tax credit.

  11. Computed tomography of the spine: Diagnostic exercises

    International Nuclear Information System (INIS)

    Kricun, R.; Kricun, M.E.

    1987-01-01

    The authors' aim is to provide diagnostic challenges and information to improve the readers' ability to interpret computed tomography (CT) scans of the spine. The entire vertebral column and adjacent soft-tissue structures are covered. The authors discuss normal findings, and congenital, traumatic, inflammatory, neoplastic, degenerative, idiopathic, and postoperative findings. Sixty-six case examples are presented, followed by description of the findings. Additional examples are given, and drawings and photographs of specimens are used to illustrate and clarify the pathologic conditions. Other modalities, including their advantages and disadvantages, are illustrated and discussed where appropriate. The relative merits of these modalities are presented

  12. Telecontrol - Expert systems. Real-time monitoring and remote diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Lam, A.

    1996-09-01

    The role of expert systems in programming simple and complex tasks in utilities companies was discussed with examples from B.C. Hydro, where expert systems have been used in such diverse applications as an in-house programmable logic controller (PLC) training course, and a machine audit on a 150 MW steam turbine generating unit at their Burrard Thermal Generating Plant. The PLC tutoring program uses expert system technology for the air blast circuit breakers` air drier system, for individualized on-site training. The steam turbine audits (an eight-month long project) were performed remotely by dialing an on-site computer configured with customized expert software. Details of these, and other potential applications, such as transformer monitoring and diagnostics, circuit breaker performance analysis, and information management, were described.

  13. A Versatile Image Processor For Digital Diagnostic Imaging And Its Application In Computed Radiography

    Science.gov (United States)

    Blume, H.; Alexandru, R.; Applegate, R.; Giordano, T.; Kamiya, K.; Kresina, R.

    1986-06-01

    In a digital diagnostic imaging department, the majority of operations for handling and processing of images can be grouped into a small set of basic operations, such as image data buffering and storage, image processing and analysis, image display, image data transmission and image data compression. These operations occur in almost all nodes of the diagnostic imaging communications network of the department. An image processor architecture was developed in which each of these functions has been mapped into hardware and software modules. The modular approach has advantages in terms of economics, service, expandability and upgradeability. The architectural design is based on the principles of hierarchical functionality, distributed and parallel processing and aims at real time response. Parallel processing and real time response is facilitated in part by a dual bus system: a VME control bus and a high speed image data bus, consisting of 8 independent parallel 16-bit busses, capable of handling combined up to 144 MBytes/sec. The presented image processor is versatile enough to meet the video rate processing needs of digital subtraction angiography, the large pixel matrix processing requirements of static projection radiography, or the broad range of manipulation and display needs of a multi-modality diagnostic work station. Several hardware modules are described in detail. For illustrating the capabilities of the image processor, processed 2000 x 2000 pixel computed radiographs are shown and estimated computation times for executing the processing opera-tions are presented.

  14. Investigation of computer-aided diagnosis system for bone scans: a retrospective analysis in 406 patients.

    Science.gov (United States)

    Tokuda, Osamu; Harada, Yuko; Ohishi, Yona; Matsunaga, Naofumi; Edenbrandt, Lars

    2014-05-01

    The aim of this study was to investigate the diagnostic ability of a completely automated computer-assisted diagnosis (CAD) system to detect metastases in bone scans by two patterns: one was per region, and the other was per patient. This study included 406 patients with suspected metastatic bone tumors who underwent whole-body bone scans that were analyzed by the automated CAD system. The patients were divided into four groups: a group with prostatic cancer (N = 71), breast cancer (N = 109), males with other cancers (N = 153), and females with other cancers (N = 73). We investigated the bone scan index and artificial neural network (ANN), which are parameters that can be used to classify bone scans to determine whether there are metastases. The sensitivities, specificities, positive predictive value (PPV), negative predictive value (NPV), and accuracies for the four groups were compared. Receiver operating characteristic (ROC) analyses of region-based ANN were performed to compare the diagnostic performance of the automated CAD system. There were no significant differences in the sensitivity, specificity, or NPV between the four groups. The PPVs of the group with prostatic cancer (51.0 %) were significantly higher than those of the other groups (P < 0.01). The accuracy of the group with prostatic cancer (81.5 %) was significantly higher than that of the group with breast cancer (68.6 %) and the females with other cancers (65.9 %) (P < 0.01). For the evaluation of the ROC analysis of region-based ANN, the highest Az values for the groups with prostatic cancer, breast cancer, males with other cancers, and females with other cancers were 0.82 (ANN = 0.4, 0.5, 0.6, 0.7, and 0.8), 0.83 (ANN = 0.7), 0.81 (ANN = 0.5), and 0.81 (ANN = 0.6), respectively. The special CAD system "BONENAVI" trained with a Japanese database appears to have significant potential in assisting physicians in their clinical routine. However, an improved CAD system depending on the primary lesion

  15. Investigation of computer-aided diagnosis system for bone scans. A retrospective analysis in 406 patients

    International Nuclear Information System (INIS)

    Tokuda, Osamu; Harada, Yuko; Ohishi, Yona; Matsunaga, Naofumi; Edenbrandt, L.

    2014-01-01

    The aim of this study was to investigate the diagnostic ability of a completely automated computer-assisted diagnosis (CAD) system to detect metastases in bone scans by two patterns: one was per region, and the other was per patient. This study included 406 patients with suspected metastatic bone tumors who underwent whole-body bone scans that were analyzed by the automated CAD system. The patients were divided into four groups: a group with prostatic cancer (N=71), breast cancer (N=109), males with other cancers (N=153), and females with other cancers (N=73). We investigated the bone scan index and artificial neural network (ANN), which are parameters that can be used to classify bone scans to determine whether there are metastases. The sensitivities, specificities, positive predictive value (PPV), negative predictive value (NPV), and accuracies for the four groups were compared. Receiver operating characteristic (ROC) analyses of region-based ANN were performed to compare the diagnostic performance of the automated CAD system. There were no significant differences in the sensitivity, specificity, or NPV between the four groups. The Pps of the group with prostatic cancer (51.0%) were significantly higher than those of the other groups (P < 0.01). The accuracy of the group with prostatic cancer (81.5%) was significantly higher than that of the group with breast cancer (68.6%) and the females with other cancers (65.9%) (P < 0.01). For the evaluation of the Roc analysis of region-based Ann, the highest Az values for the groups with prostatic cancer, breast cancer, males with other cancers, and females with other cancers were 0.82 (Ann=0.4, 0.5, 0.6, 0.7, and 0.8), 0.83 (Ann=0.7), 0.81 (Ann=0.5), and 0.81 (Ann=0.6), respectively. The special CAD system 'Bovine' trained with a Japanese database appears to have significant potential in assisting physicians in their clinical routine. However, an improved CAD system depending on the primary lesion of the cancer is

  16. Public Computer Assisted Learning Facilities for Children with Visual Impairment: Universal Design for Inclusive Learning

    Science.gov (United States)

    Siu, Kin Wai Michael; Lam, Mei Seung

    2012-01-01

    Although computer assisted learning (CAL) is becoming increasingly popular, people with visual impairment face greater difficulty in accessing computer-assisted learning facilities. This is primarily because most of the current CAL facilities are not visually impaired friendly. People with visual impairment also do not normally have access to…

  17. Embedded Systems and TensorFlow Frameworks as Assistive Technology Solutions.

    Science.gov (United States)

    Mulfari, Davide; Palla, Alessandro; Fanucci, Luca

    2017-01-01

    In the field of deep learning, this paper presents the design of a wearable computer vision system for visually impaired users. The Assistive Technology solution exploits a powerful single board computer and smart glasses with a camera in order to allow its user to explore the objects within his surrounding environment, while it employs Google TensorFlow machine learning framework in order to real time classify the acquired stills. Therefore the proposed aid can increase the awareness of the explored environment and it interacts with its user by means of audio messages.

  18. Applying Integrated Computer Assisted Media (ICAM in Teaching Vocabulary

    Directory of Open Access Journals (Sweden)

    Opick Dwi Indah

    2015-02-01

    Full Text Available The objective of this research was to find out whether the use of integrated computer assisted media (ICAM is effective to improve the vocabulary achievement of the second semester students of Cokroaminoto Palopo University. The population of this research was the second semester students of English department of Cokroaminoto Palopo University in academic year 2013/2014. The samples of this research were 60 students and they were placed into two groups: experimental and control group where each group consisted of 30 students. This research used cluster random sampling technique. The research data was collected by applying vocabulary test and it was analyzed by using descriptive and inferential statistics. The result of this research was integrated computer assisted media (ICAM can improve vocabulary achievement of the students of English department of Cokroaminoto Palopo University. It can be concluded that the use of ICAM in the teaching vocabulary is effective to be implemented in improving the students’ vocabulary achievement.

  19. Easy computer assisted teaching method for undergraduate surgery

    OpenAIRE

    Agrawal, Vijay P

    2015-01-01

    Use of computers to aid or support the education or training of people has become commonplace in medical education. Recent studies have shown that it can improve learning outcomes in diagnostic abilities, clinical skills and knowledge across different learner levels from undergraduate medical education to continuing medical education. It also enhance the educational process by increasing access to learning materials, standardising the educational process, providing opportunities for asynchron...

  20. Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    This publication presents a harmonized approach to quality assurance in the field of computed tomography applied to both diagnostics and therapy. It gives a careful analysis of the principles and specific instructions that can be used for a quality assurance programme for optimal performance and reduced patient dose in diagnostic radiology. In some cases, radiotherapy programmes are making a transition from 2-D to 3-D radiotherapy, a complex process which critically depends on accurate treatment planning. In this respect, the authors also provide detailed information about the elements needed for quality assurance testing, including those relating to accurate patient characterization as needed for radiotherapy treatment planning.

  1. Mushroom drying with solar assisted heat pump system

    International Nuclear Information System (INIS)

    Şevik, Seyfi; Aktaş, Mustafa; Doğan, Hikmet; Koçak, Saim

    2013-01-01

    Highlights: • Experimental investigation of a simple and cost effective solar assisted heat pump system. • Developing of a computer program for a drying system with different scenarios by using PLC. • Obtained less energy input with high coefficients of performance of system and more quality products. • Determination of mushroom drying properties such as moisture content, moisture ratio and drying ratio. - Abstract: In this study, a simple and cost effective solar assisted heat pump system (SAHP) with flat plate collectors and a water source heat pump has been proposed. Mushroom drying was examined experimentally in the drying system. Solar energy (SE) system and heat pump (HP) system can be used separately or together. A computer program has been developed for the system. Drying air temperature, relative humidity, weight of product values, etc. were monitored and controlled with different scenarios by using PLC. This system is cheap, good quality and sustainable and it is modeled for good quality product and increased efficiency. Thus, products could be dried with less energy input and more controlled conditions. Mushrooms were dried at 45 °C and 55 °C drying air temperature and 310 kg/h mass flow rate. Mushrooms were dried from initial moisture content 13.24 g water/g dry matter (dry basis) to final moisture content 0.07 g water/g dry matter (dry basis). Mushrooms were dried by using HP system, SE system and SAHP system respectively at 250–220 min, at 270–165 min and at 230–190 min. The coefficients of performance of system (COP) are calculated in a range from 2.1 to 3.1 with respect to the results of experiments. The energy utilization ratios (EURs) were found to vary between 0.42 and 0.66. Specific moisture extraction rate (SMER) values were found to vary between 0.26 and 0.92 kg/kW h

  2. The Impact of Computer-Assisted Instruction on Secondary School ...

    African Journals Online (AJOL)

    This research, carried out in Manicaland Province in Zimbabwe, aimed to investigate the impact of computer-assisted instruction on students' performance in Geography. The equivalent group research design which included a pre-test post-test control group design was used. Respondents to interviews and pre-test and ...

  3. Computer assisted radionuclide angiography to confirm reversible ischemic cerebral dysfunction

    International Nuclear Information System (INIS)

    Buell, U.; Lanksch, W.; Tosch, U.; Kleinhans, E.; Steinhoff, H.

    1982-01-01

    Computer assisted radionuclide angiography (CARNA) was employed in patients with transient ischemic attack (TIA) or prolonged reversible ischemic neurologic deficit (PRIND) to establish the sensitivity of CARNA in detecting and quantifying changes of cerebral perfusion in such selected patients. Moreover, results of CARNA were compared with findings of cranial radiographic angiography (RGA) to obtain data on combined sensitivities of these methods. CARNA may be the preferred noninvasive procedure employed because it detects and quantifies the vascular supply disorder in patients with TIA and PRIND. If no computer assistance is used to evaluate cranial radionuclide angiography, results are considerable less accurate. Specifity of CARNA is 84.6%. If CARNA is negative (25.2% in TIA; 12.7% in PRIND), a further method must be employed to confirm the cranial vascular origin of the attack. This may be RGA in TIA and transmission computed axial tomography (T-CAT) T-CAT in PRIND. This diagnos - tic sequence lead to 92.4% true positive in TIA and to 93.2% true positives in PRIND

  4. Computer-aided diagnostics of screening mammography using content-based image retrieval

    Science.gov (United States)

    Deserno, Thomas M.; Soiron, Michael; de Oliveira, Júlia E. E.; de A. Araújo, Arnaldo

    2012-03-01

    Breast cancer is one of the main causes of death among women in occidental countries. In the last years, screening mammography has been established worldwide for early detection of breast cancer, and computer-aided diagnostics (CAD) is being developed to assist physicians reading mammograms. A promising method for CAD is content-based image retrieval (CBIR). Recently, we have developed a classification scheme of suspicious tissue pattern based on the support vector machine (SVM). In this paper, we continue moving towards automatic CAD of screening mammography. The experiments are based on in total 10,509 radiographs that have been collected from different sources. From this, 3,375 images are provided with one and 430 radiographs with more than one chain code annotation of cancerous regions. In different experiments, this data is divided into 12 and 20 classes, distinguishing between four categories of tissue density, three categories of pathology and in the 20 class problem two categories of different types of lesions. Balancing the number of images in each class yields 233 and 45 images remaining in each of the 12 and 20 classes, respectively. Using a two-dimensional principal component analysis, features are extracted from small patches of 128 x 128 pixels and classified by means of a SVM. Overall, the accuracy of the raw classification was 61.6 % and 52.1 % for the 12 and the 20 class problem, respectively. The confusion matrices are assessed for detailed analysis. Furthermore, an implementation of a SVM-based CBIR system for CADx in screening mammography is presented. In conclusion, with a smarter patch extraction, the CBIR approach might reach precision rates that are helpful for the physicians. This, however, needs more comprehensive evaluation on clinical data.

  5. Agent assisted interactive algorithm for computationally demanding multiobjective optimization problems

    OpenAIRE

    Ojalehto, Vesa; Podkopaev, Dmitry; Miettinen, Kaisa

    2015-01-01

    We generalize the applicability of interactive methods for solving computationally demanding, that is, time-consuming, multiobjective optimization problems. For this purpose we propose a new agent assisted interactive algorithm. It employs a computationally inexpensive surrogate problem and four different agents that intelligently update the surrogate based on the preferences specified by a decision maker. In this way, we decrease the waiting times imposed on the decision maker du...

  6. Computer assisted collimation gamma camera: A new approach to imaging contaminated tissues

    International Nuclear Information System (INIS)

    Quartuccio, M.; Franck, D.; Pihet, P.; Begot, S.; Jeanguillaume, C.

    2000-01-01

    Measurement systems with the capability of imaging tissues contaminated with radioactive materials would find relevant applications in medical physics research and possibly in health physics. The latter in particular depends critically on the performance achieved for sensitivity and spatial resolution. An original approach of computer assisted collimation gamma camera (French acronym CACAO) which could meet suitable characteristics has been proposed elsewhere. CACAO requires detectors with high spatial resolution. The present work was aimed at investigating the application of the CACAO principle on a laboratory testing bench using silicon detectors made of small pixels. (author)

  7. Computer assisted collimation gamma camera: A new approach to imaging contaminated tissues

    Energy Technology Data Exchange (ETDEWEB)

    Quartuccio, M.; Franck, D.; Pihet, P.; Begot, S.; Jeanguillaume, C

    2000-07-01

    Measurement systems with the capability of imaging tissues contaminated with radioactive materials would find relevant applications in medical physics research and possibly in health physics. The latter in particular depends critically on the performance achieved for sensitivity and spatial resolution. An original approach of computer assisted collimation gamma camera (French acronym CACAO) which could meet suitable characteristics has been proposed elsewhere. CACAO requires detectors with high spatial resolution. The present work was aimed at investigating the application of the CACAO principle on a laboratory testing bench using silicon detectors made of small pixels. (author)

  8. Pre-Service Teachers' Uses of and Barriers from Adopting Computer-Assisted Language Learning (CALL) Programs

    Science.gov (United States)

    Samani, Ebrahim; Baki, Roselan; Razali, Abu Bakar

    2014-01-01

    Success in implementation of computer-assisted language learning (CALL) programs depends on the teachers' understanding of the roles of CALL programs in education. Consequently, it is also important to understand the barriers teachers face in the use of computer-assisted language learning (CALL) programs. The current study was conducted on 14…

  9. Use of a radiation therapy treatment planning computer in a hospital health physics program

    International Nuclear Information System (INIS)

    Addison, S.J.

    1984-01-01

    An onsite treatment planning computer has become state of the art in the care of radiation therapy patients, but in most installations the computer is used for therapy planning a diminutive amount of the day. At St. Mary's Hospital, arrangements have been negotiated for part time use of the treatment planning computer for health physics purposes. Computerized Medical Systems, Inc. (CMS) produces the Modulex radiotherapy planning system which is programmed in MUMPS, a user oriented language specially adapted for handling text string information. St. Mary's Hospital's CMS computer has currently been programmed to assist in data collection and write-up of diagnostic x-ray surveys, meter calibrations, and wipe/leak tests. The computer is setup to provide timely reminders of tests and surveys, and billing for consultation work. Programs are currently being developed for radionuclide inventories. Use of a therapy planning computer for health physics purposes can enhance the radiation safety program and provide additional grounds for the acquisition of such a computer system

  10. Computer-assisted diagnostic procedure for multislice computed tomography for assessment of the pulmonary arterial circulation. Clinical relevance

    International Nuclear Information System (INIS)

    Malich, A.; Hentrich, D.; Hansch, A.; Teichgraeber, U.; Boettcher, J.

    2012-01-01

    A recently developed CAD software which highlights intravascular thrombotic structures from multislice computed tomography (MSCT) data was tested regarding feasibility, interobserver reliability and effect on radiology reports. The CAD system ImageChecker registered CT-Lung was tested in a randomized double-blinded study on 160 MSCT datasets (standardized technical conditions) performed for suspected pulmonary embolism (PE). The CAD data and images were analyzed by three radiologists in an independent and blinded fashion. The data from all 160 cases could be analyzed and 604 CAD prompts were set. Using the CAD analysis significantly more PEs were found in the peripheral pulmonary arterial circulation than described in the initial report. In 38 cases the 3 radiologists in consensus scored the images with the CAD adjunct as PE positive in peripheral vessels, which were initially reported as negative. Despite differences in the evaluation between two radiologists the amended assessment of the imaging data using the CAD softwear was reliable. There was a significant correlation between D-dimer values and the number of embolic structures detected by the CAD analysis. The recently developed CAD system is a useful adjunct as second reader to detect subtle emboli in peripheral vessels of MSCT datasets. (orig.) [de

  11. Enhancing instruction in Fuels and Combustion Laboratory via a developed computer-assisted program for establishing efficient coal-diesel oil mixture (CDOM) fuel proportions

    Energy Technology Data Exchange (ETDEWEB)

    Maglaya, A.B. [La Salle University, Manila (Philippines). Dept. of Mechanical Engineering

    2004-07-01

    This paper discusses the relevance of digital computation in Fuels and Combustion Laboratory experiments used by the senior students of the Department of Mechanical Engineering, De La Salle University-Manila, Philippines. One of the students' experiments involved the determination of the most efficient CDOM fuel proportion as alternative fuel to diesel oil for steam generators and other industrial applications. Theoretical calculations show that it requires tedious and repetitive computations. A computer-assisted program was developed to lessen the time-consuming activities. The formulation of algorithms were based on the system of equations of the heat interaction between the CDOM fuel, combustion air and products of combustion and by applying the principles of mass and energy equations (or the First Law of Thermodynamics) for reacting systems were utilized. The developed computer-assisted program output verified alternative fuel selected through actual experimentation.

  12. Computer-assisted training experiment used in the field of thermal energy production (EDF)

    International Nuclear Information System (INIS)

    Felgines, R.

    1982-01-01

    In 1981, the EDF carried out an experiment with computer-assisted training (EAO). This new approach, which continued until June 1982, involved about 700 employees all of whom operated nuclear power stations. The different stages of this experiment and the lessons which can be drawn from it are given the lessons were of a positive nature and make it possible to envisage complete coverage of all nuclear power stations by computer-assisted training within a very short space of time [fr

  13. Indications for computed tomography (CT- diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography

    Directory of Open Access Journals (Sweden)

    Weise Kuno

    2009-04-01

    Full Text Available Abstract Background Precise indications for computed tomography (CT in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X-rays (22 AP + axillary views, 22 AP + scapular Y-views and CT (multi-planar reconstruction (MPR and maximum intensity projection (MIP with 2 D and 3 D imaging. 3 observers assessed the technical image quality, the assessment of the relevant anatomical structures (2-sample-t-test and the percentage of the osseous overlap of the proximal humerus (Welch-test using a scoring system. The quality of the different diagnostic methods was assessed according to the number of fractured parts (Bonferroni-Holm adjustment. Results There was significantly more overlap of the fractured region on the scapular Y-views (mean 71.5%, range 45–90% than on axillary views (mean 56.2%, range 10.5–100%. CT-diagnostics allowed a significantly better assessment of the relevant structures than conventional diagnostics (p Conclusion Conventional X-rays with AP view and a high-quality axillary view are useful for primary diagnostics of the fracture and often but not always show a clear presentation of the relevant bony structures such as both tuberosities, the glenoid and humeral head. CT with thin slices technology and additional 3 D imaging provides always a clear presentation of the fractured region. Clinically, a CT should be performed – independently of the number of fractured parts – when the proximal humerus and the shoulder joint are not presented with sufficient X-ray-quality to establish a treatment plan.

  14. Computer control system of TARN-2

    International Nuclear Information System (INIS)

    Watanabe, S.

    1989-01-01

    The CAMAC interface system is employed in order to regulate the power supply, beam diagnostic and so on. Five CAMAC stations are located in the TARN-2 area and are linked with a serial highway system. The CAMAC serial highway is driven by a serial highway driver, Kinetic 3992, which is housed in the CAMAC powered crate and regulated by two successive methods. One is regulated by the mini computer through the standard branch-highway crate controller, named Type-A2, and the other is regulated with the microcomputer through the auxiliary crate controller. The CAMAC serial highway comprises the two-way optical cables with a total length of 300 m. Each CAMAC station has the serial and auxiliary crate controllers so as to realize alternative control with the local computer system. Interpreter, INSBASIC, is used in the main control computer. There are many kinds of the 'device control function' of the INSBASIC. Because the 'device control function' implies physical operating procedure of such a device, only knowledge of the logical operating procedure is required. A touch panel system is employed to regulate the complicated control flow without any knowledge of the usage of the device. A rotary encoder system, which is analogous to the potentiometer operation, is also available for smooth adjustment of the setting parameter. (author)

  15. Expert system for fast reactor diagnostic

    International Nuclear Information System (INIS)

    Parcy, J.P.

    1982-09-01

    A general description of expert systems is given. The operation of a fast reactor is reviewed. The expert system to the diagnosis of breakdowns limited to the reactor core. The structure of the system is described: specification of the diagnostics; structure of the data bank and evaluation of the rules; specification of the prediagnostics and evaluation; explanation of the diagnostics; time evolution of the system; comparison with other expert systems. Applications to some cases of faults are finally presented [fr

  16. Computer-assisted modeling: Contributions of computational approaches to elucidating macromolecular structure and function: Final report

    International Nuclear Information System (INIS)

    Walton, S.

    1987-01-01

    The Committee, asked to provide an assessment of computer-assisted modeling of molecular structure, has highlighted the signal successes and the significant limitations for a broad panoply of technologies and has projected plausible paths of development over the next decade. As with any assessment of such scope, differing opinions about present or future prospects were expressed. The conclusions and recommendations, however, represent a consensus of our views of the present status of computational efforts in this field

  17. Advanced intelligent computational technologies and decision support systems

    CERN Document Server

    Kountchev, Roumen

    2014-01-01

    This book offers a state of the art collection covering themes related to Advanced Intelligent Computational Technologies and Decision Support Systems which can be applied to fields like healthcare assisting the humans in solving problems. The book brings forward a wealth of ideas, algorithms and case studies in themes like: intelligent predictive diagnosis; intelligent analyzing of medical images; new format for coding of single and sequences of medical images; Medical Decision Support Systems; diagnosis of Down’s syndrome; computational perspectives for electronic fetal monitoring; efficient compression of CT Images; adaptive interpolation and halftoning for medical images; applications of artificial neural networks for real-life problems solving; present and perspectives for Electronic Healthcare Record Systems; adaptive approaches for noise reduction in sequences of CT images etc.

  18. The application of DECnet TTT technique in beam diagnostical system of SSC central region

    International Nuclear Information System (INIS)

    Zhang Guixu; Huang Tuanhua

    1997-01-01

    The DECnet TTT technique and the real time network communication based on DECnet TTT are presented. Information can be transferred between console and diagnostical system via DECnet communication, so all kinds of operation can be done on console. The working computer of HIRFL console is VAX8350

  19. Transformer engineering design, technology, and diagnostics

    CERN Document Server

    Kulkarni, SV

    2012-01-01

    Transformer Engineering: Design, Technology, and Diagnostics, Second Edition helps you design better transformers, apply advanced numerical field computations more effectively, and tackle operational and maintenance issues. Building on the bestselling Transformer Engineering: Design and Practice, this greatly expanded second edition also emphasizes diagnostic aspects and transformer-system interactions. What's New in This Edition Three new chapters on electromagnetic fields in transformers, transformer-system interactions and modeling, and monitoring and diagnostics An extensively revised chap

  20. Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries

    Energy Technology Data Exchange (ETDEWEB)

    Charuakkra, Arnon; Prapayasatok, Sangsom; Janhom, Apirum; Pongsirwet, Surawut; Verochana, Karune; Mahasantipiya, Phattaranant [Faculty of Dentistry, Chiang Mai University, Chiang Mai (Thailand)

    2011-12-15

    The aim of this study was to compare the diagnostic accuracy of cone-beam computed tomography (CBCT) images and bitewing images in detection of secondary caries. One hundred and twenty proximal slots of Class II cavities were randomly prepared on human premolar and molar teeth, and restored with amalgam (n=60) and composite resin (n=60). Then, artificial secondary caries lesions were randomly created using round steel No. 4 bur. The teeth were radiographed with a conventional bitewing technique and two CBCT systems; Pax-500ECT and Promax 3D. All images were evaluated by five observers. The area under the receiver operating characteristic (ROC) curve (Az) was used to evaluate the diagnostic accuracy. Significant difference was tested using the Friedman test (p value<0.05). The mean Az values for bitewing, Pax-500ECT, and Promax 3D imaging systems were 0.882, 0.995, and 0.978, respectively. Significant differences were found between the two CBCT systems and film (p=0.007). For CBCT systems, the axial plane showed the greatest Az value. Based on the design of this study, CBCT images were better than bitewing radiographs in detection of secondary caries.

  1. Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries

    International Nuclear Information System (INIS)

    Charuakkra, Arnon; Prapayasatok, Sangsom; Janhom, Apirum; Pongsirwet, Surawut; Verochana, Karune; Mahasantipiya, Phattaranant

    2011-01-01

    The aim of this study was to compare the diagnostic accuracy of cone-beam computed tomography (CBCT) images and bitewing images in detection of secondary caries. One hundred and twenty proximal slots of Class II cavities were randomly prepared on human premolar and molar teeth, and restored with amalgam (n=60) and composite resin (n=60). Then, artificial secondary caries lesions were randomly created using round steel No. 4 bur. The teeth were radiographed with a conventional bitewing technique and two CBCT systems; Pax-500ECT and Promax 3D. All images were evaluated by five observers. The area under the receiver operating characteristic (ROC) curve (Az) was used to evaluate the diagnostic accuracy. Significant difference was tested using the Friedman test (p value<0.05). The mean Az values for bitewing, Pax-500ECT, and Promax 3D imaging systems were 0.882, 0.995, and 0.978, respectively. Significant differences were found between the two CBCT systems and film (p=0.007). For CBCT systems, the axial plane showed the greatest Az value. Based on the design of this study, CBCT images were better than bitewing radiographs in detection of secondary caries.

  2. Duplicated collecting system of a kidney complicated with hydronephrosis - diagnostic methods review: A case report

    International Nuclear Information System (INIS)

    Osmanski, P.; Plucinska, I.; Calka, K.; Kedzierski, B.; Jazwiec, P.

    2008-01-01

    Duplicated collecting system of a kidney occurs in 1.7-4.2% of the population. It is a complex, unilateral or bilateral, congenital abnormality of the pyelocalyceal system and the ureter. The 2 ureters fuse to form a single ureteral orifice or empty separately into the bladder (ureter duplex). Duplicated collecting systems with complete ureteric duplication may lead to developing vesicoureteral reflux, hydronephrosis, and urinary infection. This article presents a case of a 49-year-old woman with duplicated collecting system and hydronephrosis in the upper pole. The anomaly was diagnosed using urography, ultrasonography and computed tomography examination.The best method for diagnostics of the duplicated pyelocalyceal system complicated by hydronephrosis is computed tomography examination, especially multislice computed tomography. The authors present also the options for therapy (author)

  3. Reducing the throughput time of the diagnostic track involving CT scanning with computer simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lent, Wineke A.M. van, E-mail: w.v.lent@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); University of Twente, IGS Institute for Innovation and Governance Studies, Department of Health Technology Services Research (HTSR), Enschede (Netherlands); Deetman, Joost W., E-mail: j.deetman@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Teertstra, H. Jelle, E-mail: h.teertstra@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Muller, Sara H., E-mail: s.muller@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Hans, Erwin W., E-mail: e.w.hans@utwente.nl [University of Twente, School of Management and Governance, Dept. of Industrial Engineering and Business Intelligence Systems, Enschede (Netherlands); Harten, Wim H. van, E-mail: w.v.harten@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); University of Twente, IGS Institute for Innovation and Governance Studies, Department of Health Technology Services Research (HTSR), Enschede (Netherlands)

    2012-11-15

    Introduction: To examine the use of computer simulation to reduce the time between the CT request and the consult in which the CT report is discussed (diagnostic track) while restricting idle time and overtime. Methods: After a pre implementation analysis in our case study hospital, by computer simulation three scenarios were evaluated on access time, overtime and idle time of the CT; after implementation these same aspects were evaluated again. Effects on throughput time were measured for outpatient short-term and urgent requests only. Conclusion: The pre implementation analysis showed an average CT access time of 9.8 operating days and an average diagnostic track of 14.5 operating days. Based on the outcomes of the simulation, management changed the capacity for the different patient groups to facilitate a diagnostic track of 10 operating days, with a CT access time of 7 days. After the implementation of changes, the average diagnostic track duration was 12.6 days with an average CT access time of 7.3 days. The fraction of patients with a total throughput time within 10 days increased from 29% to 44% while the utilization remained equal with 82%, the idle time increased by 11% and the overtime decreased by 82%. The fraction of patients that completed the diagnostic track within 10 days improved with 52%. Computer simulation proved useful for studying the effects of proposed scenarios in radiology management. Besides the tangible effects, the simulation increased the awareness that optimizing capacity allocation can reduce access times.

  4. Reducing the throughput time of the diagnostic track involving CT scanning with computer simulation

    International Nuclear Information System (INIS)

    Lent, Wineke A.M. van; Deetman, Joost W.; Teertstra, H. Jelle; Muller, Sara H.; Hans, Erwin W.; Harten, Wim H. van

    2012-01-01

    Introduction: To examine the use of computer simulation to reduce the time between the CT request and the consult in which the CT report is discussed (diagnostic track) while restricting idle time and overtime. Methods: After a pre implementation analysis in our case study hospital, by computer simulation three scenarios were evaluated on access time, overtime and idle time of the CT; after implementation these same aspects were evaluated again. Effects on throughput time were measured for outpatient short-term and urgent requests only. Conclusion: The pre implementation analysis showed an average CT access time of 9.8 operating days and an average diagnostic track of 14.5 operating days. Based on the outcomes of the simulation, management changed the capacity for the different patient groups to facilitate a diagnostic track of 10 operating days, with a CT access time of 7 days. After the implementation of changes, the average diagnostic track duration was 12.6 days with an average CT access time of 7.3 days. The fraction of patients with a total throughput time within 10 days increased from 29% to 44% while the utilization remained equal with 82%, the idle time increased by 11% and the overtime decreased by 82%. The fraction of patients that completed the diagnostic track within 10 days improved with 52%. Computer simulation proved useful for studying the effects of proposed scenarios in radiology management. Besides the tangible effects, the simulation increased the awareness that optimizing capacity allocation can reduce access times.

  5. Manager's assistant systems for space system planning

    Science.gov (United States)

    Bewley, William L.; Burnard, Robert; Edwards, Gary E.; Shoop, James

    1992-01-01

    This paper describes a class of knowledge-based 'assistant' systems for space system planning. Derived from technology produced for the DARPA/USAF Pilot's Associate program, these assistant systems help the human planner by doing the bookkeeping to maintain plan data and executing the procedures and heuristics currently used by the human planner to define, assess, diagnose, and revise plans. Intelligent systems for Space Station Freedom assembly sequence planning and Advanced Launch System modeling will be presented as examples. Ongoing NASA-funded work on a framework supporting the development of such tools will also be described.

  6. From computer-assisted intervention research to clinical impact: The need for a holistic approach.

    Science.gov (United States)

    Ourselin, Sébastien; Emberton, Mark; Vercauteren, Tom

    2016-10-01

    The early days of the field of medical image computing (MIC) and computer-assisted intervention (CAI), when publishing a strong self-contained methodological algorithm was enough to produce impact, are over. As a community, we now have substantial responsibility to translate our scientific progresses into improved patient care. In the field of computer-assisted interventions, the emphasis is also shifting from the mere use of well-known established imaging modalities and position trackers to the design and combination of innovative sensing, elaborate computational models and fine-grained clinical workflow analysis to create devices with unprecedented capabilities. The barriers to translating such devices in the complex and understandably heavily regulated surgical and interventional environment can seem daunting. Whether we leave the translation task mostly to our industrial partners or welcome, as researchers, an important share of it is up to us. We argue that embracing the complexity of surgical and interventional sciences is mandatory to the evolution of the field. Being able to do so requires large-scale infrastructure and a critical mass of expertise that very few research centres have. In this paper, we emphasise the need for a holistic approach to computer-assisted interventions where clinical, scientific, engineering and regulatory expertise are combined as a means of moving towards clinical impact. To ensure that the breadth of infrastructure and expertise required for translational computer-assisted intervention research does not lead to a situation where the field advances only thanks to a handful of exceptionally large research centres, we also advocate that solutions need to be designed to lower the barriers to entry. Inspired by fields such as particle physics and astronomy, we claim that centralised very large innovation centres with state of the art technology and health technology assessment capabilities backed by core support staff and open

  7. Automated detection of heuristics and biases among pathologists in a computer-based system.

    Science.gov (United States)

    Crowley, Rebecca S; Legowski, Elizabeth; Medvedeva, Olga; Reitmeyer, Kayse; Tseytlin, Eugene; Castine, Melissa; Jukic, Drazen; Mello-Thoms, Claudia

    2013-08-01

    The purpose of this study is threefold: (1) to develop an automated, computer-based method to detect heuristics and biases as pathologists examine virtual slide cases, (2) to measure the frequency and distribution of heuristics and errors across three levels of training, and (3) to examine relationships of heuristics to biases, and biases to diagnostic errors. The authors conducted the study using a computer-based system to view and diagnose virtual slide cases. The software recorded participant responses throughout the diagnostic process, and automatically classified participant actions based on definitions of eight common heuristics and/or biases. The authors measured frequency of heuristic use and bias across three levels of training. Biases studied were detected at varying frequencies, with availability and search satisficing observed most frequently. There were few significant differences by level of training. For representativeness and anchoring, the heuristic was used appropriately as often or more often than it was used in biased judgment. Approximately half of the diagnostic errors were associated with one or more biases. We conclude that heuristic use and biases were observed among physicians at all levels of training using the virtual slide system, although their frequencies varied. The system can be employed to detect heuristic use and to test methods for decreasing diagnostic errors resulting from cognitive biases.

  8. Cybernetic Security and Business Intelligence in the System of Diagnostics of Economic Security of the Enterprise

    Directory of Open Access Journals (Sweden)

    Ruslan Skrynkovskyy

    2017-10-01

    Full Text Available The purpose of the article is to determine the place, the role and features of cybernetic security and improve the business intelligence scheme in the system of diagnosing economic security of the enterprise. It had been found out that: 1 the term “cybernetic security of an enterprise” should be understood as the state of the protection of the cybernetic space of the whole enterprise or individual objects of its information infrastructure (computer system, computer data, etc. from the risk of external cybernetic influence, which ensures their sustainable development and the formation of prospects, as well as timely detection, prevention and neutralization of real and potential cybernetic interruptions and threats to the interests of the enterprise; 2 the main components of cybernetic security in the system of diagnostics of economic security of the enterprise are: investigation of information and telecommunication systems and cryptosystems of the opposing sides; cybernetic effects; protection of information sphere. It was established that the main task of business intelligence in the system of diagnosing economic security of the enterprise is the verification of the reliability of business information, the provision of cybernetic protection of information resources, information and communication technologies and systems and the elimination of the possibility of misinformation of senior management by the managers of the middle level, suppliers, marketing intermediaries, clientele, competitors or contact audiences of the enterprise. The prospect of further research in this direction is the development of a system of goals of the polycriterial diagnostics of the activity (economic diagnostics of the enterprise (on the basis of the isolation and systematization of its diagnostic purposes, taking into account the presented results of the study.

  9. Intelligent Computer-Assisted Instruction: A Review and Assessment of ICAI Research and Its Potential for Education.

    Science.gov (United States)

    Dede, Christopher J.; And Others

    The first of five sections in this report places intelligent computer-assisted instruction (ICAI) in its historical context through discussions of traditional computer-assisted instruction (CAI) linear and branching programs; TICCIT and PLATO IV, two CAI demonstration projects funded by the National Science Foundation; generative programs, the…

  10. Ruling Out Brain CT Contraindications prior to Intravenous Thrombolysis: Diagnostic Equivalence between a Primary Interpretation Workstation and a Mobile Tablet Computer

    Directory of Open Access Journals (Sweden)

    Antonio J. Salazar

    2017-01-01

    Full Text Available Objective. The aim of this study was to evaluate the equivalence of brain CT interpretations performed using a diagnostic workstation and a mobile tablet computer, in a telestroke service. Materials and Methods. The ethics committee of our institution approved this retrospective study. A factorial design with 1452 interpretations was used. The assessed variables were the type of stroke classification, the presence of contraindications to the tPA administration, the presence of a hyperdense intracranial artery sign (HMCA, and the Alberta Stroke Program Early CT Score (ASPECTS score. These variables were evaluated to determine the effect that the reading system had on their magnitudes. Results. The achieved distribution of observed lesions using both the reading systems was not statistically different. The differences between the two reading systems to claim equivalence were 1.6% for hemorrhagic lesions, 4.5% for cases without lesion, and 5.2 for overall ischemic lesion. Equivalence was achieved at 2.1% for ASPECTS ≤ 6, 6.5% for the presence of imaging contraindication to the tPA administration, and 7.2% for the presence of HMCA. Conclusion. The diagnostic performance for detecting acute stroke is likely equivalent whether a tablet computer or a diagnostic workstation is used or not.

  11. Indications for computed tomography (CT-) diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography

    OpenAIRE

    Weise Kuno; Pereira Philippe L; Dietz Klaus; Eingartner Christoph; Schmal Hagen; Südkamp Norbert P; Rolauffs Bernd; Bahrs Christian; Lingenfelter Erich; Helwig Peter

    2009-01-01

    Abstract Background Precise indications for computed tomography (CT) in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X...

  12. MAS: Malware Analysis System Based on Hardware-Assisted Virtualization Technology

    Science.gov (United States)

    Kim, Taehyoung; Kim, Inhyuk; Min, Changwoo; Eom, Young Ik

    There are many analysis techniques in order to analyze malicious codes. However, recently malicious codes often evade detection using stealthy obfuscation techniques, and attack computing systems. We propose an enhanced dynamic binary instrumentation using hardware-assisted virtualization technology. As a machine-level analyzer, our system can be isolated from almost the whole threats of malware, and provides single step analysis environment. Proposed system also supports rapid system call analysis environment. We implement our malware analysis system (referred as MAS) on the KVM hypervisor with Intel VT-x virtualization support. Our experiments with benchmarks show that the proposed system provides efficient analysis environment with low overhead.

  13. Computer-assisted radiological quantification of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Peloschek, P.L.

    2000-03-01

    Specific objective was to develop the layout and structure of a platform for effective quantification of rheumatoid arthritis (RA). A fully operative Java stand-alone application software (RheumaCoach) was developed to support the efficacy of the scoring process in RA (Web address: http://www.univie.ac.at/radio/radio.htm). Addressed as potential users of such a program are physicians enrolled in clinical trials to evaluate the course of RA and its modulation with drug therapies and scientists developing new scoring modalities. The software 'RheumaCoach' consists of three major modules: The Tutorial starts with 'Rheumatoid Arthritis', to teach the basic pathology of the disease. Afterwards the section 'Imaging Standards' explains how to produce proper radiographs. 'Principles - How to use the 'Larsen Score', 'Radiographic Findings' and 'Quantification by Scoring' explain the requirements for unbiased scoring of RA. At the Data Input Sheet care was taken to follow the radiologist's approach in analysing films as published previously. At the compute sheet the calculated Larsen-Score may be compared with former scores and the further possibilities (calculate, export, print, send) are easily accessible. In a first pre-clinical study the system was tested in an unstructured. Two structured evaluations (30 fully documented and blinded cases of RA, four radiologists scored hands and feet with or without the RheumaCoach) followed. Between the evaluations we permanently improved the software. For all readers the usage of the RheumaCoach fastened the procedure, all together the scoring without computer-assistance needed about 20 % percent more time. Availability of the programme via the internet provides common access for potential quality control in multi-center studies. Documentation of results in a specifically designed printout improves communication between radiologists and rheumatologists. The possibilities of direct export to other programmes and electronic

  14. The Effects of a Computer-Assisted Teaching Material, Designed According to the ASSURE Instructional Design and the ARCS Model of Motivation, on Students’ Achievement Levels in a Mathematics Lesson and Their Resulting Attitudes

    OpenAIRE

    Hilal Karakış; Ayşen Karamete; Aydın Okçu

    2016-01-01

    This study examined the effects that computer-assisted instruction had on students’ attitudes toward a mathematics lesson and toward learning mathematics with computer-assisted instruction. The computer software we used was based on the ASSURE Instructional Systems Design and the ARCS Model of Motivation, and the software was designed to teach fractions to fourth-grade students. The skill levels of these students were gauged before and after receiving the computer-assisted instruction. We str...

  15. Computer-assisted assessment of the Human Epidermal Growth Factor Receptor 2 immunohistochemical assay in imaged histologic sections using a membrane isolation algorithm and quantitative analysis of positive controls

    International Nuclear Information System (INIS)

    Hall, Bonnie H; Ianosi-Irimie, Monica; Javidian, Parisa; Chen, Wenjin; Ganesan, Shridar; Foran, David J

    2008-01-01

    Breast cancers that overexpress the human epidermal growth factor receptor 2 (HER2) are eligible for effective biologically targeted therapies, such as trastuzumab. However, accurately determining HER2 overexpression, especially in immunohistochemically equivocal cases, remains a challenge. Manual analysis of HER2 expression is dependent on the assessment of membrane staining as well as comparisons with positive controls. In spite of the strides that have been made to standardize the assessment process, intra- and inter-observer discrepancies in scoring is not uncommon. In this manuscript we describe a pathologist assisted, computer-based continuous scoring approach for increasing the precision and reproducibility of assessing imaged breast tissue specimens. Computer-assisted analysis on HER2 IHC is compared with manual scoring and fluorescence in situ hybridization results on a test set of 99 digitally imaged breast cancer cases enriched with equivocally scored (2+) cases. Image features are generated based on the staining profile of the positive control tissue and pixels delineated by a newly developed Membrane Isolation Algorithm. Evaluation of results was performed using Receiver Operator Characteristic (ROC) analysis. A computer-aided diagnostic approach has been developed using a membrane isolation algorithm and quantitative use of positive immunostaining controls. By incorporating internal positive controls into feature analysis a greater Area Under the Curve (AUC) in ROC analysis was achieved than feature analysis without positive controls. Evaluation of HER2 immunostaining that utilized membrane pixels, controls, and percent area stained showed significantly greater AUC than manual scoring, and significantly less false positive rate when used to evaluate immunohistochemically equivocal cases. It has been shown that by incorporating both a membrane isolation algorithm and analysis of known positive controls a computer-assisted diagnostic algorithm was

  16. Feedback in Computer Assisted Pronunciation Training: When technology meets pedagogy

    NARCIS (Netherlands)

    Neri, A.; Cucchiarini, C.; Strik, H.

    2002-01-01

    Computer Assisted Language Learning (CALL) has now established itself as a prolific and fast growing area whose advantages are already well-known to educators. Yet, many authors lament the lack of a reliable integrated conceptual framework linking technology advances and second language acquisition

  17. Design of a magnetic field alignment diagnostic for the MFTF-B magnet system

    International Nuclear Information System (INIS)

    Deadrick, F.J.; House, P.A.; Frye, R.W.

    1985-01-01

    Magnet alignment in tandem mirror fusion machines plays a crucial role in achieving and maintaining plasma confinement. Various visual alignment tools have been described by Post et al. to align the Tara magnet system. We have designed and installed a remotely operated magnetic field alignment (MFA) diagnostic system as a part of the Mirror Fusion Test Facility (MFTF-B). It measures critical magnetic field alignment parameters of the MFTF-B coil set while under full-field operating conditions. The MFA diagnostic employs a pair of low-energy, electron beam guns on a remotely positionable probe to trace and map selected magnetic field lines. An array of precision electrical detector paddles locates the position of the electron beam, and thus the magnetic field line, at several critical points. The measurements provide a means to compute proper compensating currents to correct for mechanical misalignments of the magnets with auxiliary trim coils if necessary. This paper describes both the mechanical and electrical design of the MFA diagnostic hardware

  18. Vacuum system design and tritium inventory for the charge exchange diagnostic on the Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Medley, S.S.

    1986-01-01

    The application of charge exchange analyzers for the measurement of ion temperature in fusion plasma experiments requires a direct connection between the diagnostic and plasma-discharge vacuum chambers. Differential pumping of the gas load from the diagnostic stripping cell operated at > or approx. = 10 -3 Torr is required to maintain the analyzer chamber at a pressure of -6 Torr. The migration of gases between the diagnostic and plasma vacuum chambers must be minimized. In particular, introduction of the analyzer stripping cell gas into the plasma chamber having a base pressure of -8 Torr must be suppressed. The charge exchange diagnostic for the Tokamak Fusion Test Reactor (TFTR) is comprised of two analyzer systems designed to contain a total of 18 independent mass/energy analyzers and one diagnostic neutral beam rated at 80 keV, 15 A. The associated arrays of multiple, interconnected vacuum systems were analyzed using the Vacuum System Transient Simulator (Vsts) computer program which models the transient transport of multigas species through complex networks of ducts, valves, traps, vacuum pumps, and other related vacuum system components. In addition to providing improved design performance at reduced costs, the analysis yields estimates for the exchange of tritium from the torus to the diagnostic components and of the diagnostic working gases to the torus

  19. Colonic polyps: inheritance, susceptibility, risk evaluation, and diagnostic management

    Directory of Open Access Journals (Sweden)

    Emanuele Neri

    2010-12-01

    Full Text Available Emanuele Neri, Lorenzo Faggioni, Lorenzo Cini, Carlo BartolozziDiagnostic and Interventional Radiology, University of Pisa, Pisa, ItalyAbstract: Colorectal cancer (CRC is the third-ranked neoplasm in order of incidence and mortality, worldwide, and the second cause of cancer death in industrialized countries. One of the most important environmental risk factors for CRC is a Western-type diet, which is characterized by a low-fiber and high-fat content. Up to 25% of patients with CRC have a family history for CRC, and a fraction of these patients are affected by hereditary syndromes, such as familial adenomatous polyposis, Gardner or Turcot syndromes, or hereditary nonpolyposis colorectal cancer. The onset of CRC is triggered by a well-defined combination of genetic alterations, which form the bases of the adenoma-carcinoma sequence hypothesis and justify the set-up of CRC screening techniques. Several screening and diagnostic tests for CRC are illustrated, including rectosigmoidoscopy, optical colonoscopy (OC, double contrast barium enema (DCBE, and computed tomography colonography (CTC. The strengths and weaknesses of each technique are discussed. Particular attention is paid to CTC, which has evolved from an experimental technique to an accurate and mature diagnostic approach, and gained wide acceptance and clinical validation for CRC screening. This success of CTC is due mainly to its ability to provide cross-sectional analytical images of the entire colon and secondarily detect extracolonic findings, with minimal invasiveness and lower cost than OC, and with greater detail and diagnostic accuracy than DCBE. Moreover, especially with the advent and widespread availability of modern multidetector CT scanners, excellent quality 2D and 3D reconstructions of the large bowel can be obtained routinely with a relatively low radiation dose. Computer-aided detection systems have also been developed to assist radiologists in reading CTC examinations

  20. Quality Computer Assisted Mobile Learning (CAML and Distance Education Leadership in Managing Technology Enhanced Learning Management System (TELMS in the Malaysian Public Tertiary Education

    Directory of Open Access Journals (Sweden)

    Lee Tan Luck

    2009-07-01

    Full Text Available Abstract - The success in the implementation of a quality computer assisted mobile learning and distance education in a Technology Enhanced Learning Management System is highly rely on the academic leadership in managing and application of Information and Communication Technology (ICT in the tertiary level. The effectiveness of its leadership, knowledge, application and management of ICT and learning management system is of utmost important. Successful application and management includes quality and cost effectiveness of universities administration, CAML and distance education leadership development, organizational culture, academic staffs and students’ attitude and their commitment towards teaching and learning process, support towards the usage of state of the art techno-educational facilities, availability of ICT resources, maintenance and funding of a Learning Management System. This paper will discuss the above factors, which present a comprehensive framework for the implementation of a quality CAML and distance education environment in ICT application and management in the Malaysian public universities. Selected Fifty-two respondents from two Malaysian public universities which offer e Learning and distance education with Learning Management System were acquired. A survey questionnaire is used to determine the effectiveness of ICT and mobile learning application management. Data from the questionnaires were analyzed by using non-parametric and parametric statistics testing. Results of this study show there is significant different in the CAML and distance education leadership in TELMS and the application of ICT and its management in the Malaysian public universities. The study will also address the implementation elements necessary for transforming the public universities and its CAML and distance education teaching and learning process into an effective and result oriented computer assisted mobile learning management model in public

  1. IMPLEMENTATION OF TURNOUTS TECHNICAL DIAGNOSTICS SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. YU. Buryak

    2015-06-01

    Full Text Available Purpose. In the paper it is necessary to: 1 find out the causes of turnouts faults to determine diagnostic features failures; 2 consider the requirements structure, purpose components of turnouts, work and technology of their maintenance to determine the construction of the economic activities related to system to the turnout’s maintenance; 3 substantiate the possibility, necessity and prospects of automated diagnostics turnout’s implementation; 4 elaborate a prototype of an automated hardware and software system for the turnouts control parameters and perform diagnostics on them. Methodology. In the paper possible turnouts faults were presented and manifestations and influence on its work were shown. According to the current technology works the process analyze of turnouts’ maintenance was conducted, were defined the basic performed operations during the examination of appearance, parameters and check the repair or replacement of parts and assemblies. Based on the analysis of reasons of turnouts malfunctioning and their fixes were systematized types of damages and ways to deal with them, an information scheme of troubleshooting were created, opportunities and limits of automating the process of diagnostics were identified and compared with the existing method of turnouts maintenance. A diagnostics system block diagram was created, an algorithm of its work was developed and established main basic principles of operation. Software and hardware to determine the turnout’s state considering diagnostic performance of points in use were applied. Findings. During the experiment was created a method of automated turnout’s diagnostics with AC electric drives, managed centrally. The results of automated hardware and software system make it possible to control turnout’s parameters and perform diagnostics on them. Originality. Authors created the method of turnout’s state determination by current curve and its spectral composition in the

  2. COMPUTER ASSISTED LOOM IN THE REVIVAL OF CONTEMPORARY MONUMENTAL TAPESTRY

    Directory of Open Access Journals (Sweden)

    PINTILIE Anca-Aurelia

    2015-05-01

    Full Text Available The art of tapestry has its basics back in time, probably in the decorations of tent, the house of the nomad. Tapestry in its beginnings is the first wall of the nomad’s home and the decorative wall and canopy in the ancient Greek houses as architect Gottfried Semper stated in the nineteen century. The architectural approach is not unusual even in the next centuries. Tapestry becomes popular as a form of monumental art during the Middle Ages when it is used as decorative architectural element, coating the walls of medieval castles. During the next centuries dominated by decadent styles of baroque, rococo, the tapestry will lose its monumental spirit and architectural quality but at the middle of the XXth century a new approach will sustain the revival of the tapestry as monumental art. Later, in the XXIst century, renowned multimedia artists will approach this medium and will use computer assisted looms in ambitious tapestry projects. This technique will allow them to realize complex and exquisite tapestries, sustaining in this way the revival of the tapestry in the contemporary art world. The paper presents the importance of the architectural side of tapestry and the great achievement that computer assisted loom represents for this form of art. The research activity is willing to inform Romanian textile designers about the possibilities to create tapestries on computer assisted looms. The research was made during the initial stage of a doctoral thesis consisting in a documentary study on monumental aspects of contemporary tapestry.

  3. Selection of examples in case-based computer-aided decision systems

    International Nuclear Information System (INIS)

    Mazurowski, Maciej A; Zurada, Jacek M; Tourassi, Georgia D

    2008-01-01

    Case-based computer-aided decision (CB-CAD) systems rely on a database of previously stored, known examples when classifying new, incoming queries. Such systems can be particularly useful since they do not need retraining every time a new example is deposited in the case base. The adaptive nature of case-based systems is well suited to the current trend of continuously expanding digital databases in the medical domain. To maintain efficiency, however, such systems need sophisticated strategies to effectively manage the available evidence database. In this paper, we discuss the general problem of building an evidence database by selecting the most useful examples to store while satisfying existing storage requirements. We evaluate three intelligent techniques for this purpose: genetic algorithm-based selection, greedy selection and random mutation hill climbing. These techniques are compared to a random selection strategy used as the baseline. The study is performed with a previously presented CB-CAD system applied for false positive reduction in screening mammograms. The experimental evaluation shows that when the development goal is to maximize the system's diagnostic performance, the intelligent techniques are able to reduce the size of the evidence database to 37% of the original database by eliminating superfluous and/or detrimental examples while at the same time significantly improving the CAD system's performance. Furthermore, if the case-base size is a main concern, the total number of examples stored in the system can be reduced to only 2-4% of the original database without a decrease in the diagnostic performance. Comparison of the techniques shows that random mutation hill climbing provides the best balance between the diagnostic performance and computational efficiency when building the evidence database of the CB-CAD system.

  4. A Computer-Assisted Instruction in Teaching Abstract Statistics to Public Affairs Undergraduates

    Science.gov (United States)

    Ozturk, Ali Osman

    2012-01-01

    This article attempts to demonstrate the applicability of a computer-assisted instruction supported with simulated data in teaching abstract statistical concepts to political science and public affairs students in an introductory research methods course. The software is called the Elaboration Model Computer Exercise (EMCE) in that it takes a great…

  5. DALIS: a computer-assisted document retrieval system for the FFTF

    International Nuclear Information System (INIS)

    Harves, W.G.

    1981-01-01

    The FFTF (Fast Flux Test Facility) is a liquid sodium cooled, fast flux reactor designed specifically for irradiation testing of fuels and components for liquid metal fast breeder reactors. The Department of Energy and the Nuclear Regulatory Commission require that all pertinent documentation for maintenance, operation, and safety of the FFTF be readily accessible and retrievable, both during initial startup and for the lifetime of the plant. That amounts to a lot of information which has to be retrievable. The indexing system finally developed is called the DALIS system, short for Document and Location Indexing System. This system was designed by an engineer (Michael Theo) for use by engineers. DALIS uses descriptiors and keywords to identify each document in the system. The descriptors give such information as document number, date of issuance of the document, the title, the originating organization, and the microfilm or hardcopy location of the document. The keywords are words or phrases that describe the content of the document and permit retrieval by means of a computer search for documents with the stated keywords

  6. Effects of a Computer-Assisted Concept Mapping Learning Strategy on EFL College Students' English Reading Comprehension

    Science.gov (United States)

    Liu, Pei-Lin; Chen, Chiu-Jung; Chang, Yu-Ju

    2010-01-01

    The purpose of this research was to investigate the effects of a computer-assisted concept mapping learning strategy on EFL college learners' English reading comprehension. The research questions were: (1) what was the influence of the computer-assisted concept mapping learning strategy on different learners' English reading comprehension? (2) did…

  7. Effect of Tutorial Mode of Computer-Assisted Instruction on Students ...

    African Journals Online (AJOL)

    This study investigated the effect of Tutorial Mode of Computer- Assisted Instruction (CAI) on students' academic performance in practical geography in Nigeria, However, the sample population of eighty (80) Senior Secondary School Two geography students that were randomly selected from two privately owned secondary ...

  8. Markov analysis of different standby computer based systems

    International Nuclear Information System (INIS)

    Srinivas, G.; Guptan, Rajee; Mohan, Nalini; Ghadge, S.G.; Bajaj, S.S.

    2006-01-01

    As against the conventional triplicated systems of hardware and the generation of control signals for the actuator elements by means of redundant hardwired median circuits, employed in the early Indian PHWR's, a new approach of generating control signals based on software by a redundant system of computers is introduced in the advanced/current generation of Indian PHWR's. Reliability is increased by fault diagnostics and automatic switch over of all the loads to one computer in case of total failure of the other computer. Independent processing by a redundant CPU in each system enables inter-comparison to quickly identify system failure, in addition to the other self-diagnostic features provided. Combinatorial models such as reliability block diagrams and fault trees are frequently used to predict the reliability, maintainability and safety of complex systems. Unfortunately, these methods cannot accurately model dynamic system behavior; Because of its unique ability to handle dynamic cases, Markov analysis can be a powerful tool in the reliability maintainability and safety (RMS) analyses of dynamic systems. A Markov model breaks the system configuration into a number of states. Each of these states is connected to all other states by transition rates. It then utilizes transition matrices to evaluate the reliability and safety of the systems, either through matrix manipulation or other analytical solution methods, such as Laplace transforms. Thus, Markov analysis is a powerful reliability, maintainability and safety analysis tool. It allows the analyst to model complex, dynamic, highly distributed, fault tolerant systems that would otherwise be very difficult to model using classical techniques like the Fault tree method. The Dual Processor Hot Standby Process Control System (DPHS-PCS) and the Computerized Channel Temperature Monitoring System (CCTM) are typical examples of hot standby systems in the Indian PHWR's. While such systems currently in use in Indian PHWR

  9. Computer Assisted REhabilitation (CARE) Lab: A novel approach towards Pediatric Rehabilitation 2.0.

    Science.gov (United States)

    Olivieri, Ivana; Meriggi, Paolo; Fedeli, Cristina; Brazzoli, Elena; Castagna, Anna; Roidi, Marina Luisa Rodocanachi; Angelini, Lucia

    2018-01-01

    Pediatric Rehabilitation therapists have always worked using a variety of off-the-shelf or custom-made objects and devices, more recently including computer based systems. These Information and Communication Technology (ICT) solutions vary widely in complexity, from easy-to-use interactive videogame consoles originally intended for entertainment purposes to sophisticated systems specifically developed for rehabilitation.This paper describes the principles underlying an innovative "Pediatric Rehabilitation 2.0" approach, based on the combination of suitable ICT solutions and traditional rehabilitation, which has been progressively refined while building up and using a computer-assisted rehabilitation laboratory. These principles are thus summarized in the acronym EPIQ, to account for the terms Ecological, Personalized, Interactive and Quantitative. The paper also presents the laboratory, which has been designed to meet the children's rehabilitation needs and to empower therapists in their work. The laboratory is equipped with commercial hardware and specially developed software called VITAMIN: a virtual reality platform for motor and cognitive rehabilitation.

  10. Computer assisted orthopaedic and trauma surgery. State of the art and future perspectives

    NARCIS (Netherlands)

    Schep, N. W. L.; Broeders, I. A. M. J.; van der Werken, Chr

    2003-01-01

    In recent years computer technologies have become more and more integrated in surgical procedures. The potential advantages of computer assisted surgery (CAS) are: increase of accuracy of surgical interventions, less invasive operations, better planning and simulation and reduction of radiation

  11. A Self-Diagnostic System for the M6 Accelerometer

    Science.gov (United States)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  12. Complications of fixed infrared emitters in computer-assisted total knee arthroplasties

    Directory of Open Access Journals (Sweden)

    Suárez-Vázquez Abelardo

    2007-07-01

    Full Text Available Abstract Background The first stage in the implant of a total knee arthroplasty with computer-assisted surgery is to fasten the emitters to the femur and the tibia. These trackers must be hard-fixed to the bone. The objectives of our study are to evaluate the technical problems and complications of these tracker-pins, the necessary time to fix them to the bone and the possible advantages of a new femoral-fixed tracker-pin. Methods Three hundred and sixty seven tracker-pins were used in one hundred and fifty one computer-assisted total knee replacements. A bicortical screw was used to fix the tracker to the tibia in all cases; in the femur, however, a bicortical tracker was used in 112 cases, while a new device (OrthoLock with percutaneous fixation pins was employed in the remaining 39. Results Technical problems related to the fixing of the trackers appeared in nine cases (2.5%. The mean surgery time to fix the tracker pin to the tibia was 3 minutes (range 2–7, and 5 minutes in the case of the femoral pin (range: 4–11, although with the new tool it was only three minutes (range 2–4 (p Conclusion The incidence of problems and complications with the fixing systems used in knee navigation is very small. The use of a new device with percutaneous pins facilitates the fixing of femoral trackers and decreases the time needed to place them.

  13. Prediction of temperature-insensitive molecular absorption lines in laser-assisted combustion diagnostics

    International Nuclear Information System (INIS)

    Walewski, Joachim W.; Elmqvist, Anders

    2005-01-01

    In laser-assisted combustion diagnostics it is a recurring task to predict molecular transitions whose signal strength depends only weakly on variations in temperature. The signal strength is proportional to the Boltzmann fraction of the level probed and the amplitude of the absorption line profile. In the past investigations have been presented in which this task was attack by detailed numerical calculations of the temperature dependence of pertinent physical properties of the molecule. Another widely applied approach relies on an analytical formula for the Boltzmann fraction of hetero-nuclear diatomic molecules and the neglect of line shape effects. The analytical approach experiences a continuing popularity in laser-assisted combustion diagnostics, which is why we compared both approaches with each other. The objective of this comparison was to assess the accuracy of the analytical approach and to reveal its potential pitfalls. Our comparison revealed that the analytical approach suffers from mediocre accuracy, which makes it unfit for practical applications. One cause is the neglect of higher lying vibrational levels, which show a non-negligible population for typical flame temperatures. Another reason is the neglect of fine structure splitting in molecules with non-zero orbit angular momentum in the ground state. Another reason for the observed inaccuracy is the neglect of line shape effects quenching, which were found to have a significant effect on the temperature sensitivity of a line. Because of its insufficient accuracy due to both oversimplified models of the molecular energy levels and the neglect of line shape effects and quenching we discourage from applying the analytical approach and recommend the use of detailed numerical approaches that are free of the above limitations

  14. Natural language processing tools for computer assisted language learning

    Directory of Open Access Journals (Sweden)

    Vandeventer Faltin, Anne

    2003-01-01

    Full Text Available This paper illustrates the usefulness of natural language processing (NLP tools for computer assisted language learning (CALL through the presentation of three NLP tools integrated within a CALL software for French. These tools are (i a sentence structure viewer; (ii an error diagnosis system; and (iii a conjugation tool. The sentence structure viewer helps language learners grasp the structure of a sentence, by providing lexical and grammatical information. This information is derived from a deep syntactic analysis. Two different outputs are presented. The error diagnosis system is composed of a spell checker, a grammar checker, and a coherence checker. The spell checker makes use of alpha-codes, phonological reinterpretation, and some ad hoc rules to provide correction proposals. The grammar checker employs constraint relaxation and phonological reinterpretation as diagnosis techniques. The coherence checker compares the underlying "semantic" structures of a stored answer and of the learners' input to detect semantic discrepancies. The conjugation tool is a resource with enhanced capabilities when put on an electronic format, enabling searches from inflected and ambiguous verb forms.

  15. Hybrid case-neural network (CNN) diagnostic system

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2010-01-01

    recently, the mobile health care has a great attention for the researcher and people all over the world. Case based reasoning (CBR) systems have proved their performance as world wide web (WWW) medical diagnostic systems. They were preferred rather than different reasoning approaches due to their high performance and results' explanation. But, their operations require a complex knowledge acquisition and management processes. On the other hand, it is found that, artificial neural network (ANN) has a great acceptance as a classifier methodology using a little amount of knowledge. But, ANN lacks of an explanation capability .The present research introduces a new web-based hybrid diagnostic system that can use the ANN inside the CBR , cycle.It can provide higher performance for the web diagnostic systems. Besides, the proposed system can be used as a web diagnostic system. It can be applied for diagnosis different types of systems in several domains. It has been applied in diagnosis of the cancer diseases that has a great spreading in recent years as a case of study . However, the suggested system has proved its acceptance in the manner.

  16. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    Science.gov (United States)

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual

  17. Radiation effects in IFMIF Li target diagnostic systems

    International Nuclear Information System (INIS)

    Molla, J.; Vila, R.; Shikama, T.; Horiike, H.; Simakov, S.; Ciotti, M.; Ibarra, A.

    2009-01-01

    Diagnostics for the lithium target will be crucial for the operation of IFMIF. Several parameters as the lithium temperature, target thickness or wave pattern must be monitored during operation. Radiation effects may produce malfunctioning in any of these diagnostics due to the exposure to high radiation fields. The main diagnostic systems proposed for the operation of IFMIF are reviewed in this paper from the point of view of radiation damage. The main tools for the assessment of the performance of these diagnostics are the neutronics calculations by using specialised codes and the information accumulated during the last decades on the radiation effects in functional materials, components and diagnostics for ITER. This analysis allows to conclude that the design of some of the diagnostic systems must be revised to assure the high availability required for the target system.

  18. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  19. Effects of Using Simultaneous Prompting and Computer-Assisted Instruction during Small Group Instruction

    Science.gov (United States)

    Ozen, Arzu; Ergenekon, Yasemin; Ulke-Kurkcuoglu, Burcu

    2017-01-01

    The current study investigated the relation between simultaneous prompting (SP), computer-assisted instruction (CAI), and the receptive identification of target pictures (presented on laptop computer) for four preschool students with developmental disabilities. The students' acquisition of nontarget information through observational learning also…

  20. MFTF plasma diagnostics data acquisition system

    International Nuclear Information System (INIS)

    Davis, G.E.; Coffield, F.E.

    1979-01-01

    The initial goal of the Data Acquisition System (DAS) is to control 11 instruments chosen as the startup diagnostic set and to collect, process, and display the data that these instruments produce. These instruments are described in a paper by Stan Thomas, et. al. entitled ''MFTF Plasma Diagnostics System.'' The DAS must be modular and flexible enough to allow upgrades in the quantity of data taken by an instrument, and also to allow new instruments to be added to the system. This is particularly necessary to support a research project where needs and requirements may change rapidly as a result of experimental findings. Typically, the startup configuration of the diagnostic instruments will contain only a fraction of the planned detectors, and produce approximately one half the data that the expanded version is designed to generate. Expansion of the system will occur in fiscal year 1982

  1. Multimedia-assisted breathwalk-aware system.

    Science.gov (United States)

    Yu, Meng-Chieh; Wu, Huan; Lee, Ming-Sui; Hung, Yi-Ping

    2012-12-01

    Breathwalk is a science of combining specific patterns of footsteps synchronized with the breathing. In this study, we developed a multimedia-assisted Breathwalk-aware system which detects user's walking and breathing conditions and provides appropriate multimedia guidance on the smartphone. Through the mobile device, the system enhances user's awareness of walking and breathing behaviors. As an example application in slow technology, the system could help meditator beginners learn "walking meditation," a type of meditation which aims to be as slow as possible in taking pace, to synchronize footstep with breathing, and to land every footstep with toes first. In the pilot study, we developed a walking-aware system and evaluated whether multimedia-assisted mechanism is capable of enhancing beginner's walking awareness while walking meditation. Experimental results show that it could effectively assist beginners in slowing down the walking speed and decreasing incorrect footsteps. In the second experiment, we evaluated the Breathwalk-aware system to find a better feedback mechanism for learning the techniques of Breathwalk while walking meditation. The experimental results show that the visual-auditory mechanism is a better multimedia-assisted mechanism while walking meditation than visual mechanism and auditory mechanism.

  2. Residual heat removal system diagnostic advisor

    International Nuclear Information System (INIS)

    Tripp, L.

    1991-01-01

    This paper reports on the Residual Heat Removal System (RHRS) Diagnostic Advisor which is an expert system designed to alert the operators to abnormal conditions that exits in the RHRS and offer advice about the cause of the abnormal conditions. The Advisor uses a combination of rule-based and model-based diagnostic techniques to perform its functions. This diagnostic approach leads to a deeper understanding of the RHRS by the Advisor and consequently makes it more robust to unexpected conditions. The main window of the interactive graphic display is a schematic diagram of the RHRS piping system. When a conclusion about a failed component can be reached, the operator can bring up windows that describe the failure mode of the component and a brief explanation about how the Advisor arrived at its conclusion

  3. A virtual computing infrastructure for TS-CV SCADA systems

    CERN Document Server

    Poulsen, S

    2008-01-01

    In modern data centres, it is an emerging trend to operate and manage computers as software components or logical resources and not as physical machines. This technique is known as â€ワvirtualisation” and the new computers are referred to as â€ワvirtual machines” (VMs). Multiple VMs can be consolidated on a single hardware platform and managed in ways that are not possible with physical machines. However, this is not yet widely practiced for control system deployment. In TS-CV, a collection of VMs or a â€ワvirtual infrastructure” is installed since 2005 for SCADA systems, PLC program development, and alarm transmission. This makes it possible to consolidate distributed, heterogeneous operating systems and applications on a limited number of standardised high-performance servers in the Central Control Room (CCR). More generally, virtualisation assists in offering continuous computing services for controls and maintaining performance and assuring quality. Implementing our systems in a vi...

  4. Computational Flame Diagnostics for Direct Numerical Simulations with Detailed Chemistry of Transportation Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Tianfeng [Univ. of Connecticut, Storrs, CT (United States)

    2017-02-16

    The goal of the proposed research is to create computational flame diagnostics (CFLD) that are rigorous numerical algorithms for systematic detection of critical flame features, such as ignition, extinction, and premixed and non-premixed flamelets, and to understand the underlying physicochemical processes controlling limit flame phenomena, flame stabilization, turbulence-chemistry interactions and pollutant emissions etc. The goal has been accomplished through an integrated effort on mechanism reduction, direct numerical simulations (DNS) of flames at engine conditions and a variety of turbulent flames with transport fuels, computational diagnostics, turbulence modeling, and DNS data mining and data reduction. The computational diagnostics are primarily based on the chemical explosive mode analysis (CEMA) and a recently developed bifurcation analysis using datasets from first-principle simulations of 0-D reactors, 1-D laminar flames, and 2-D and 3-D DNS (collaboration with J.H. Chen and S. Som at Argonne, and C.S. Yoo at UNIST). Non-stiff reduced mechanisms for transportation fuels amenable for 3-D DNS are developed through graph-based methods and timescale analysis. The flame structures, stabilization mechanisms, local ignition and extinction etc., and the rate controlling chemical processes are unambiguously identified through CFLD. CEMA is further employed to segment complex turbulent flames based on the critical flame features, such as premixed reaction fronts, and to enable zone-adaptive turbulent combustion modeling.

  5. A multi-laser system for a fast sampling Thomson scattering diagnostic

    International Nuclear Information System (INIS)

    Trost, P.K.; Carlstrom, T.N.; DeBoo, J.C.; Greenfield, C.M.; Hsieh, C.L.; Snider, R.T.

    1990-10-01

    A multi-laser system is being developed for the DIII-D Thomson scattering diagnostic. This system combines the beams from up to eight Nd:YAG lasers onto a common beamline in which the beams are nearly parallel and are all focused into a small, common area within the desired scattering volume. Each laser can be fired at a constant rate (20 Hz per laser) for a high average repetition rate, or together in a ''burst,'' which will give very high sampling rates (10--20 kHz) for short periods. The burst mode will be triggerable by plasma events, which will allow for study of transient phenomena, but will require non-periodic firing of the lasers. Beamline diagnostics include position sensitive detectors for computer controlled feedback alignment of the 35 m beamline, an image position detection system for monitoring the alignment of the collection lens to the scattering volume, and a 1-D reticon camera for divergence monitoring. The effects of the non-periodic firing of the lasers will be monitored with the reticon camera. 3 refs., 5 figs

  6. Assistive and Rehabilitation Robotic System

    Directory of Open Access Journals (Sweden)

    Adrian Abrudean

    2015-06-01

    Full Text Available A short introduction concerning the content of Assistive Technology and Rehabilitation Engineering is followed by a study of robotic systems which combine two or more assistive functions. Based on biomechanical aspects, a complex robotic system is presented, starting with the study of functionality and ending with the practical aspects of the prototype development.

  7. Automatic measurement system for congenital hip dislocation using a computed radiography

    International Nuclear Information System (INIS)

    Komori, M.; Minato, K.; Hirakawa, A.; Kuwahara, M.

    1988-01-01

    Acetabular angle which is a diagnostic parameter of congenital hip dislocation has been measured manually in conventional X-ray film system. Using digital image directly provided from a computed radiography, an automatic measurement system was developed for this parameter. The process of the measurement was completed within a reasonable time, and accurate enough. The system was combined with an image database, so that it would be a measurement tool of PACS

  8. Image-guided navigation system for placing dental implants.

    Science.gov (United States)

    Casap, Nardy; Wexler, Alon; Lustmann, Joshua

    2004-10-01

    Navigation-guided surgery has recently been introduced into various surgical disciplines, including oral and maxillofacial surgery. Since the advent of dental implants, dental computed tomography (CT) scans have been used as a diagnostic tool for preoperative planning, but not as part of the surgical phase. This article explains the principles of computer-assisted surgery and describes the use of a computer-guided navigation system in dental implantology. The system uses preoperative dental CT scans for planning and as an integral part of the surgical procedure. This system allows continuous intraoperative coordination of the implantation phase with the preoperative plan, optimizing the accuracy of implant surgery. Deviations from the planned location of the implants are minimal. Several cases are discussed.

  9. 21 CFR 884.6200 - Assisted reproduction laser system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction laser system. 884.6200... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6200 Assisted reproduction laser system. (a) Identification. The assisted reproduction laser system is a device...

  10. Expert system for assisting the repair operations on the control racks of the control rods assembly in a 900 MW PWR type reactor

    International Nuclear Information System (INIS)

    Monnier, B.; Doutre, J.L.; Franco, A.

    1990-01-01

    The expert system presented was developed for assisting the repair operations on the control equipment of the control rod assembly in a PWR type reactor. The expert system allows the representation of expert knowledge and diagnostic reasoning. The objective of the expert system is to achieve the most precise diagnostic and localizing of the breakdown elements, by processing the data acquired during breakdown. The development steps, the structure and the applications of the expert system are summarized. The expert system operates in an IBM PC equipped with a AMAIA 8 Mo card. A time schedule of 18 months is predicted [fr

  11. Audio computer-assisted self interview compared to traditional interview in an HIV-related behavioral survey in Vietnam.

    Science.gov (United States)

    Le, Linh Cu; Vu, Lan T H

    2012-10-01

    Globally, population surveys on HIV/AIDS and other sensitive topics have been using audio computer-assisted self interview for many years. This interview technique, however, is still new to Vietnam and little is known about its application and impact in general population surveys. One plausible hypothesis is that residents of Vietnam interviewed using this technique may provide a higher response rate and be more willing to reveal their true behaviors than if interviewed with traditional methods. This study aims to compare audio computer-assisted self interview with traditional face-to-face personal interview and self-administered interview with regard to rates of refusal and affirmative responses to questions on sensitive topics related to HIV/AIDS. In June 2010, a randomized study was conducted in three cities (Ha Noi, Da Nan and Can Tho), using a sample of 4049 residents aged 15 to 49 years. Respondents were randomly assigned to one of three interviewing methods: audio computer-assisted self interview, personal face-to-face interview, and self-administered paper interview. Instead of providing answers directly to interviewer questions as with traditional methods, audio computer-assisted self-interview respondents read the questions displayed on a laptop screen, while listening to the questions through audio headphones, then entered responses using a laptop keyboard. A MySQL database was used for data management and SPSS statistical package version 18 used for data analysis with bivariate and multivariate statistical techniques. Rates of high risk behaviors and mean values of continuous variables were compared for the three data collection methods. Audio computer-assisted self interview showed advantages over comparison techniques, achieving lower refusal rates and reporting higher prevalence of some sensitive and risk behaviors (perhaps indication of more truthful answers). Premarital sex was reported by 20.4% in the audio computer-assisted self-interview survey

  12. An easy-to-use diagnostic system development shell

    Science.gov (United States)

    Tsai, L. C.; Ross, J. B.; Han, C. Y.; Wee, W. G.

    1987-01-01

    The Diagnostic System Development Shell (DSDS), an expert system development shell for diagnostic systems, is described. The major objective of building the DSDS is to create a very easy to use and friendly environment for knowledge engineers and end-users. The DSDS is written in OPS5 and CommonLisp. It runs on a VAX/VMS system. A set of domain independent, generalized rules is built in the DSDS, so the users need not be concerned about building the rules. The facts are explicitly represented in a unified format. A powerful check facility which helps the user to check the errors in the created knowledge bases is provided. A judgement facility and other useful facilities are also available. A diagnostic system based on the DSDS system is question driven and can call or be called by other knowledge based systems written in OPS5 and CommonLisp. A prototype diagnostic system for diagnosing a Philips constant potential X-ray system has been built using the DSDS.

  13. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  14. Computer-assisted technologies used in oral rehabilitation and the clinical documentation of alleged advantages - a systematic review.

    Science.gov (United States)

    Jokstad, A

    2017-04-01

    The objective of this systematic review is to identify current computer-assisted technologies used for managing patients with a need to re-establish craniofacial appearance, subjective discomfort and stomatognathic function, and the extent of their clinical documentation. Electronic search strategies were used for locating clinical studies in MEDLINE through PubMed and in the Cochrane library, and in the grey literature through searches on Google Scholar. The searches for commercial digital products for use in oral rehabilitation resulted in identifying 225 products per November 2016, used for patient diagnostics, communication and therapy purposes, and for other computer-assisted applications in context with oral rehabilitation. About one-third of these products were described in about 350 papers reporting from clinical human studies. The great majority of digital products for use in oral rehabilitation has no clinical documentation at all, while the products from a distinct minority of manufacturers have frequently appeared in more or less scientific reports. Moore's law apply also to digital dentistry, which predicts that the capacity of microprocessors will continue to become faster and with lower cost per performance unit, and innovative software programs will harness these improvements in performance. The net effect is the noticeable short product life cycle of digital products developed for use in oral rehabilitation and often lack of supportive clinical documentation. Nonetheless, clinicians must request clinically meaningful information about new digital products to assess net benefits for the patients or the dental professionals and not accept only technological verbiage as a basis for product purchases. © 2017 John Wiley & Sons Ltd.

  15. Optimizing Computer Assisted Instruction By Applying Principles of Learning Theory.

    Science.gov (United States)

    Edwards, Thomas O.

    The development of learning theory and its application to computer-assisted instruction (CAI) are described. Among the early theoretical constructs thought to be important are E. L. Thorndike's concept of learning connectisms, Neal Miller's theory of motivation, and B. F. Skinner's theory of operant conditioning. Early devices incorporating those…

  16. Computer-Assisted Instruction: A Case Study of Two Charter Schools

    Science.gov (United States)

    Keengwe, Jared; Hussein, Farhan

    2013-01-01

    The purpose of this study was to examine the relationship in achievement gap between English language learners (ELLs) utilizing computer-assisted instruction (CAI) in the classroom, and ELLs relying solely on traditional classroom instruction. The study findings showed that students using CAI to supplement traditional lectures performed better…

  17. A study on the nuclear computer code maintenance and management system

    International Nuclear Information System (INIS)

    Kim, Yeon Seung; Huh, Young Hwan; Lee, Jong Bok; Choi, Young Gil; Suh, Soong Hyok; Kang, Byong Heon; Kim, Hee Kyung; Kim, Ko Ryeo; Park, Soo Jin

    1990-12-01

    According to current software development and quality assurance trends. It is necessary to develop computer code management system for nuclear programs. For this reason, the project started in 1987. Main objectives of the project are to establish a nuclear computer code management system, to secure software reliability, and to develop nuclear computer code packages. Contents of performing the project in this year were to operate and maintain computer code information system of KAERI computer codes, to develop application tool, AUTO-i, for solving the 1st and 2nd moments of inertia on polygon or circle, and to research nuclear computer code conversion between different machines. For better supporting the nuclear code availability and reliability, assistance from users who are using codes is required. Lastly, for easy reference about the codes information, we presented list of code names and information on the codes which were introduced or developed during this year. (Author)

  18. MTX [Microwave Tokamak Experiment] plasma diagnostic system

    International Nuclear Information System (INIS)

    Rice, B.W.; Hooper, E.B.; Brooksby, C.A.

    1987-01-01

    In this paper, a general overview of the MTX plasma diagnostics system is given. This includes a description of the MTX machine configuration and the overall facility layout. The data acquisition system and techniques for diagnostic signal transmission are also discussed. In addition, the diagnostic instruments planned for both an initial ohmic-heating set and a second FEL-heating set are described. The expected range of plasma parameters along with the planned plasma measurements will be reviewed. 7 refs., 5 figs

  19. Flexible human machine interface for process diagnostics

    International Nuclear Information System (INIS)

    Reifman, J.; Graham, G.E.; Wei, T.Y.C.; Brown, K.R.; Chin, R.Y.

    1996-01-01

    A flexible human machine interface to design and display graphical and textual process diagnostic information is presented. The system operates on different computer hardware platforms, including PCs under MS Windows and UNIX Workstations under X-Windows, in a client-server architecture. The interface system is customized for specific process applications in a graphical user interface development environment by overlaying the image of the process piping and instrumentation diagram with display objects that are highlighted in color during diagnostic display. Customization of the system is presented for Commonwealth Edison's Braidwood PWR Chemical and Volume Control System with transients simulated by a full-scale operator-training simulator and diagnosed by a computer-based system

  20. The Effects of a Computer-Assisted Teaching Material, Designed According to the ASSURE Instructional Design and the ARCS Model of Motivation, on Students' Achievement Levels in a Mathematics Lesson and Their Resulting Attitudes

    Science.gov (United States)

    Karakis, Hilal; Karamete, Aysen; Okçu, Aydin

    2016-01-01

    This study examined the effects that computer-assisted instruction had on students' attitudes toward a mathematics lesson and toward learning mathematics with computer-assisted instruction. The computer software we used was based on the ASSURE Instructional Systems Design and the ARCS Model of Motivation, and the software was designed to teach…