WorldWideScience

Sample records for computer-aided objective ceus

  1. Framework for Computer-Aided Evolution of Object-Oriented Designs

    NARCIS (Netherlands)

    Ciraci, S.; van den Broek, P.M.; Aksit, Mehmet

    2008-01-01

    In this paper, we describe a framework for the computer aided evolution of the designs of object-oriented software systems. Evolution mechanisms are software structures that prepare software for certain type of evolutions. The framework uses a database which holds the evolution mechanisms, modeled

  2. EVAR: Benefits of CEUS for monitoring stent-graft status

    International Nuclear Information System (INIS)

    Cantisani, Vito; Grazhdani, Hektor; Clevert, Dirk-André; Iezzi, Roberto; Aiani, Luca; Martegani, Alberto; Fanelli, Fabrizio; Di Marzo, Luca; Wlderk, Andrea; Cirelli, Carlo; Catalano, Carlo; Di Leo, Nicola; Di Segni, Mattia; Malpassini, Flavio; D’Ambrosio, Ferdinando

    2015-01-01

    Highlights: • In the last two decades several studies have shown the role of contrast enhanced ultrasound [CEUS] in post-EVAR surveillance, with very good diagnostic performance, absence of renal impairment, and no radiation, accompanied by low costs, in comparison with CTA. • In numerous prospective studies and meta-analyses the detection and characterization of endoleaks with CEUS is comparable to that of CTA imaging. • Nowadays in the EVAR surveillance novel strategies which involve CEUS with a central role, are suggested by several authors and applied in many institutions. • CEUS technique, findings, diagnostic accuracy, and its role in the follow up program are discussed in this review article. - Abstract: Endo vascular aortic repair [EVAR] is performed with low peri-operative morbidity and mortality rate and short hospital stay. However, EVAR needs a close and lifelong imagining surveillance for a timely detection of possible complications including endoleaks, graft migration, fractures, and enlargement of aneurysm sac size with eventual rupture. Contrast enhanced computed tomography [CTA] is actually considered the gold-standard in EVAR follow-up, but it is accompanied with radiation burden and renal injury due to the use of contrast media. In the last two decades several studies have shown the role of contrast enhanced ultrasound [CEUS] in post-EVAR surveillance, with very good diagnostic performance, absence of renal impairment, and no radiation, accompanied by low costs, in comparison with CTA. In numerous prospective studies and meta-analyses the detection and characterization of endoleaks with CEUS is comparable to that of CTA imaging. Nowadays, in the EVAR surveillance novel strategies which involve CEUS with a central role, are suggested by several authors and applied in many institutions. In this review article we will present a comprehensive overview and analyses of the literature on the CEUS state-of-art imagining of EVAR follow-up, with

  3. Is CEUS (contrast enhanced ultrasonography a useful tool in a beginner’s hands? How much can CAD (computer assisted diagnosis prototype help us in the characterization of malignancy in focal lesions of the liver?

    Directory of Open Access Journals (Sweden)

    Tudor Voicu Moga1,

    2016-12-01

    Full Text Available OBJECTIVES CEUS improved the characterization of focal lesions of the liver (FLLs, but it remains an operator-dependent method. The goal of this scientific paper was to test a computer assisted diagnosis (CAD prototype. MATERIALS AND METHODS 97 CEUS videos [34% hepatocellular carcinomas (HCC, 12.3% hypervascular metastases (HiperM, 11.3% hypovascular metastases (HipoM, 24.7% hemangiomas (HMG, 17.5% focal nodular hyperplasia (FNH] were used to develop a CAD prototype based on an algorithm that tested a binary decision classifier. Two young MDs, two experts and the CAD prototype, reevaluated 50 CEUS videos (diagnosis of benign vs. malignant lesions, in order to evaluate the beginner vs. expert diagnostic gap, the first being blinded by clinical data. RESULTS I-Beginner misdiagnosed 4/10-FNH, 3/10-HCC, 2/10-HMG, 1/10-HiperM, 1/10-HipoM. After being informed about the clinical data 2/10-FNH, 1/10-HCC. II-beginner misdiagnosed: 3/10-FNH; 3/10-HCC, 2/10- HMG, 1/10-HiperM. Unblinded: 1/10-HCC, 1/10- HMG. I-Expert: only 1/10-FNH, 1/10-HCC, 1/10- HMG misdiagnosed. Unblinded: all lesions were correctly diagnosed. II-Expert: 1/10-FNH, 1/10-HCC misdiagnosed. Unblinded: only 1/10-FNH was misdiagnosed. The CAD classifier managed a 75.2% overall correct classification rate. The overall classification before and after the uncovering of clinical data was: I beginner 78 %; 94%, II 82%; 96%. I expert 94%; 100%. II 96%; 98%. CONCLUSIONS The CAD prototype can assist a beginner for a better CEUS diagnostic accuracy. The integration of clinical data in the CAD algorithm is essential. Graphical abstract: Average Intensity variation in Arterial and Late Phase with supra unitary (meaning wash in and sub unitary pattern (meaning washout. REFERENCES 1.Sugimoto K, Shiraishi J, Moriyasu F, Doi K. Computer-aided diagnosis for contrast-enhanced ultrasound in the liver. World J Gastroenterol. 2010;2:215-223. 2. Gatos I, Tsantis S, Spiliopoulos S, Skouroliakou A, Theotokas I

  4. Central and Eastern United States (CEUS) Seismic Source Characterization (SSC) for Nuclear Facilities

    International Nuclear Information System (INIS)

    Coppersmith, Kevin J.; Salomone, Lawrence A.; Fuller, Chris W.; Glaser, Laura L.; Hanson, Kathryn L.; Hartleb, Ross D.; Lettis, William R.; Lindvall, Scott C.; McDuffie, Stephen M.; McGuire, Robin K.; Stirewalt, Gerry L.; Toro, Gabriel R.; Youngs, Robert R.; Slayter, David L.; Bozkurt, Serkan B.; Cumbest, Randolph J.; Falero, Valentina Montaldo; Perman, Roseanne C.; Shumway, Allison M.; Syms, Frank H.; Tuttle, Martitia P.

    2012-01-01

    This report describes a new seismic source characterization (SSC) model for the Central and Eastern United States (CEUS). It will replace the Seismic Hazard Methodology for the Central and Eastern United States, EPRI Report NP-4726 (July 1986) and the Seismic Hazard Characterization of 69 Nuclear Plant Sites East of the Rocky Mountains, Lawrence Livermore National Laboratory Model, (Bernreuter et al., 1989). The objective of the CEUS SSC Project is to develop a new seismic source model for the CEUS using a Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 assessment process. The goal of the SSHAC process is to represent the center, body, and range of technically defensible interpretations of the available data, models, and methods. Input to a probabilistic seismic hazard analysis (PSHA) consists of both seismic source characterization and ground motion characterization. These two components are used to calculate probabilistic hazard results (or seismic hazard curves) at a particular site. This report provides a new seismic source model. Results and Findings The product of this report is a regional CEUS SSC model. This model includes consideration of an updated database, full assessment and incorporation of uncertainties, and the range of diverse technical interpretations from the larger technical community. The SSC model will be widely applicable to the entire CEUS, so this project uses a ground motion model that includes generic variations to allow for a range of representative site conditions (deep soil, shallow soil, hard rock). Hazard and sensitivity calculations were conducted at seven test sites representative of different CEUS hazard environments. Challenges and Objectives The regional CEUS SSC model will be of value to readers who are involved in PSHA work, and who wish to use an updated SSC model. This model is based on a comprehensive and traceable process, in accordance with SSHAC guidelines in NUREG/CR-6372, Recommendations for Probabilistic

  5. Central and Eastern United States (CEUS) Seismic Source Characterization (SSC) for Nuclear Facilities Project

    Energy Technology Data Exchange (ETDEWEB)

    Kevin J. Coppersmith; Lawrence A. Salomone; Chris W. Fuller; Laura L. Glaser; Kathryn L. Hanson; Ross D. Hartleb; William R. Lettis; Scott C. Lindvall; Stephen M. McDuffie; Robin K. McGuire; Gerry L. Stirewalt; Gabriel R. Toro; Robert R. Youngs; David L. Slayter; Serkan B. Bozkurt; Randolph J. Cumbest; Valentina Montaldo Falero; Roseanne C. Perman' Allison M. Shumway; Frank H. Syms; Martitia (Tish) P. Tuttle

    2012-01-31

    This report describes a new seismic source characterization (SSC) model for the Central and Eastern United States (CEUS). It will replace the Seismic Hazard Methodology for the Central and Eastern United States, EPRI Report NP-4726 (July 1986) and the Seismic Hazard Characterization of 69 Nuclear Plant Sites East of the Rocky Mountains, Lawrence Livermore National Laboratory Model, (Bernreuter et al., 1989). The objective of the CEUS SSC Project is to develop a new seismic source model for the CEUS using a Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 assessment process. The goal of the SSHAC process is to represent the center, body, and range of technically defensible interpretations of the available data, models, and methods. Input to a probabilistic seismic hazard analysis (PSHA) consists of both seismic source characterization and ground motion characterization. These two components are used to calculate probabilistic hazard results (or seismic hazard curves) at a particular site. This report provides a new seismic source model. Results and Findings The product of this report is a regional CEUS SSC model. This model includes consideration of an updated database, full assessment and incorporation of uncertainties, and the range of diverse technical interpretations from the larger technical community. The SSC model will be widely applicable to the entire CEUS, so this project uses a ground motion model that includes generic variations to allow for a range of representative site conditions (deep soil, shallow soil, hard rock). Hazard and sensitivity calculations were conducted at seven test sites representative of different CEUS hazard environments. Challenges and Objectives The regional CEUS SSC model will be of value to readers who are involved in PSHA work, and who wish to use an updated SSC model. This model is based on a comprehensive and traceable process, in accordance with SSHAC guidelines in NUREG/CR-6372, Recommendations for Probabilistic

  6. Diagnostic accuracy of contrast-enhanced ultrasound for the differential diagnosis of hepatocellular carcinoma: ESCULAP versus CEUS-LI-RADS.

    Science.gov (United States)

    Schellhaas, Barbara; Görtz, Ruediger S; Pfeifer, Lukas; Kielisch, Christian; Neurath, Markus F; Strobel, Deike

    2017-09-01

    A comparison is made of two contrast-enhanced ultrasound (CEUS) algorithms for the diagnosis of hepatocellular carcinoma (HCC) in high-risk patients: Erlanger Synopsis of Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at Risk (ESCULAP) and American College of Radiology Contrast-Enhanced Ultrasound-Liver Imaging Reporting and Data System (ACR-CEUS-LI-RADSv.2016). Focal liver lesions in 100 high-risk patients were assessed using both CEUS algorithms (ESCULAP and CEUS-LI-RADSv.2016) for a direct comparison. Lesions were categorized according to size and contrast enhancement in the arterial, portal venous and late phases.For the definite diagnosis of HCC, categories ESCULAP-4, ESCULAP-Tr and ESCULAP-V and CEUS-LI-RADS-LR-5, LR-Tr and LR-5-V were compared. In addition, CEUS-LI-RADS-category LR-M (definitely/probably malignant, but not specific for HCC) and ESCULAP-category C [intrahepatic cholangiocellular carcinoma (ICC)] were compared.Histology, CE-computed tomography and CE-MRI served as reference standards. The reference standard among 100 lesions included 87 HCCs, six ICCs and seven non-HCC-non-ICC-lesions. For the diagnosis of HCC, the diagnostic accuracy of CEUS was significantly higher with ESCULAP versus CEUS-LI-RADS (94.3%/72.4%; pdiagnostic accuracy for ICC (LR-M/ESCULAP-C) was identical with both algorithms (50%), with higher PPV for ESCULAP-C versus LR-M (75 vs. 50%). CEUS-based algorithms contribute toward standardized assessment and reporting of HCC-suspect lesions in high-risk patients. ESCULAP shows significantly higher diagnostic accuracy, sensitivity and negative predictive value with no loss of specificity compared with CEUS-LI-RADS. Both algorithms have an excellent PPV. Arterial hyperenhancement is the key feature for the diagnosis of HCC with CEUS. Washout should not be a necessary prerequisite for the diagnosis of definite HCC. CEUS-LI-RADS in its current version is inferior to ESCULAP for the noninvasive diagnosis of HCC

  7. Computer-aided safety systems of industrial high energy objects

    International Nuclear Information System (INIS)

    Topolsky, N.G.; Gordeev, S.G.

    1995-01-01

    Modern objects of fuel and energy, chemical industries are characterized by high power consumption; by presence of large quantities of combustible and explosive substances used in technological processes; by advanced communications of submission systems of initial liquid and gasiform reagents, lubricants and coolants, the products of processing, and wastes of production; by advanced ventilation and pneumatic transport; and by complex control systems of energy, material and information flows. Such objects have advanced infrastructures, including a significant quantity of engineering buildings intended for storage, transportation, and processing of combustible liquids, gasiform fuels and materials, and firm materials. Examples of similar objects are nuclear and thermal power stations, chemical plants, machine-building factories, iron and steel industry enterprises, etc. Many tasks and functions characterizing the problem of fire safety of these objects can be accomplished only upon the development of special Computer-Aided Fire Safety Systems (CAFSS). The CAFSS for these objects are intended to reduce the hazard of disastrous accidents both causing fires and caused by them. The tasks of fire prevention and rescue work of large-scale industrial objects are analyzed within the bounds of the recommended conception. A functional structure of CAFSS with a list of the main subsystems forming a part of its composition has been proposed

  8. Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography

    Science.gov (United States)

    Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2013-01-01

    OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418

  9. Computer-Aided Modeling Framework

    DEFF Research Database (Denmark)

    Fedorova, Marina; Sin, Gürkan; Gani, Rafiqul

    Models are playing important roles in design and analysis of chemicals based products and the processes that manufacture them. Computer-aided methods and tools have the potential to reduce the number of experiments, which can be expensive and time consuming, and there is a benefit of working...... development and application. The proposed work is a part of the project for development of methods and tools that will allow systematic generation, analysis and solution of models for various objectives. It will use the computer-aided modeling framework that is based on a modeling methodology, which combines....... In this contribution, the concept of template-based modeling is presented and application is highlighted for the specific case of catalytic membrane fixed bed models. The modeling template is integrated in a generic computer-aided modeling framework. Furthermore, modeling templates enable the idea of model reuse...

  10. A two-stage multi-view learning framework based computer-aided diagnosis of liver tumors with contrast enhanced ultrasound images.

    Science.gov (United States)

    Guo, Le-Hang; Wang, Dan; Qian, Yi-Yi; Zheng, Xiao; Zhao, Chong-Ke; Li, Xiao-Long; Bo, Xiao-Wan; Yue, Wen-Wen; Zhang, Qi; Shi, Jun; Xu, Hui-Xiong

    2018-04-04

    With the fast development of artificial intelligence techniques, we proposed a novel two-stage multi-view learning framework for the contrast-enhanced ultrasound (CEUS) based computer-aided diagnosis for liver tumors, which adopted only three typical CEUS images selected from the arterial phase, portal venous phase and late phase. In the first stage, the deep canonical correlation analysis (DCCA) was performed on three image pairs between the arterial and portal venous phases, arterial and delayed phases, and portal venous and delayed phases respectively, which then generated total six-view features. While in the second stage, these multi-view features were then fed to a multiple kernel learning (MKL) based classifier to further promote the diagnosis result. Two MKL classification algorithms were evaluated in this MKL-based classification framework. We evaluated proposed DCCA-MKL framework on 93 lesions (47 malignant cancers vs. 46 benign tumors). The proposed DCCA-MKL framework achieved the mean classification accuracy, sensitivity, specificity, Youden index, false positive rate, and false negative rate of 90.41 ± 5.80%, 93.56 ± 5.90%, 86.89 ± 9.38%, 79.44 ± 11.83%, 13.11 ± 9.38% and 6.44 ± 5.90%, respectively, by soft margin MKL classifier. The experimental results indicate that the proposed DCCA-MKL framework achieves best performance for discriminating benign liver tumors from malignant liver cancers. Moreover, it is also proved that the three-phase CEUS image based CAD is feasible for liver tumors with the proposed DCCA-MKL framework.

  11. The role of contrast-enhanced ultrasound (CEUS) in visualizing atherosclerotic carotid plaque vulnerability: Which injection protocol? Which scanning technique?

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, Roberto, E-mail: roberto.iezzi@rm.unicatt.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Petrone, Gianluigi [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Ferrante, Angela [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Lauriola, Libero [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Vincenzoni, Claudio [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Torre, Michele Fabio la [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Snider, Francesco [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Rindi, Guido [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Bonomo, Lorenzo [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy)

    2015-05-15

    Highlights: • CEUS is a safe and efficacious technique for the identification and characterization of carotid plaque. • CEUS represents a diagnostic tool for the management of patients with carotid plaque, particularly in asymptomatic patients. • Improved diagnostic performance is achieved with the injection of 4 mL bolus of contrast-medium. • Improved diagnostic performance is achieved with the use of Dynamic Imaging rather than late-phase imaging. - Abstract: Purpose: To correlate the degree of plaque vulnerability as determined by contrast-enhanced ultrasound (CEUS) with histological findings. Secondary objectives were to optimize the CEUS acquisition technique and image evaluation methods. Materials and methods: Fifty consecutive patients, either symptomatic and asymptomatic referring to our department in order to perform carotid endarterectomy (TEA), were enrolled. Each patient provided informed consent before undergoing CEUS. Ultrasound examination was performed using high-frequency (8–14 MHz) linear probe and a non-linear pulse inversion technique (mechanical index: 0.09–1.3). A double contrast media injection (Sonovue, 2 mL and 4 mL; Bracco, Italy) was performed. Two videotapes were recorded for every injection: early “dynamic” phase and late “flash” phase, performed with 6 high mechanical index impulses. Movies were quantitatively and qualitatively evaluated. Qualitative and quantitative evaluation were statistically compared to immunohistological diagnosis of vulnerable plaque, considered as gold standard. Results: Qualitative CEUS evaluation obtained high statistical results when compared to immunohistological results, with values of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of 94%, 68%, 87%, 85% and 86%, respectively, which became higher if considering only asymptomatic patient, with a NPV of 91%. Nevertheless, quantitative software evaluation proved less

  12. California Commercial End-Use Survey - CEUS

    Science.gov (United States)

    Efficiency in Existing Buildings Energy Efficiency Program Contacts Financing Opportunities Home Energy Rebates and Incentives Energy Efficiency Financing Energy Innovations Small Grant (EISG) EPIC Funding commercial building type categories. Download the CEUS Project Final Report. Publication # CEC-400-2006-005

  13. Perfusion pattern and time of vascularisation with CEUS increase accuracy in differentiating between benign and malignant tumours in 216 musculoskeletal soft tissue masses

    Energy Technology Data Exchange (ETDEWEB)

    De Marchi, Armanda, E-mail: armanda.demarchi@tiscali.it [Department of Imaging, Azienda Ospedaliera Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy); Prever, Elena Brach del, E-mail: elena.brach@unito.it [Department of OrthopaedicOncology and ReconstructiveSurgery, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy); Cavallo, Franco, E-mail: franco.cavallo@unito.it [Department of Public health and Paediatrics, University of Turin, Via Santena 5-bis, 10126 Torino (Italy); Pozza, Simona, E-mail: simona.pozza@tin.it [Department of Imaging, Azienda Ospedaliera Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy); Linari, Alessandra, E-mail: linaralessandra@libero.it [Department of Pathology, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, Regina Margherita Hospital, Piazza Polonia, 10126 Torino (Italy); Lombardo, Paolo, E-mail: pao.lombardo82@gmail.com [Department of DiagnosticImaging and Radiotherapy of the University of Turin, Azienda Ospedaliero-Universitaria Città della Salute e della Scienza di Torino, Via Genova 3, 10126 Torino (Italy); Comandone, Alessandro, E-mail: alessandro.comandone@gradenigo.it [Department of Oncology, Gradenigo Hospital, Corso Regina Margherita, 8/10.10153 Torino (Italy); Piana, Raimondo, E-mail: raimondo.piana@libero.it [Department of OrthopaedicOncology and ReconstructiveSurgery, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy); Faletti, Carlo [Department of Imaging, Azienda Ospedaliera Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino (Italy)

    2015-01-15

    Introduction: Musculoskeletal Soft Tissue Tumours (STT) are frequent heterogeneous lesions. Guidelines consider a mass larger than 5 cm and deep with respect to the deep fascia potentially malignant. Contrast Enhanced Ultrasound (CEUS) can detect both vascularity and tumour neoangiogenesis. We hypothesised that perfusion patterns and vascularisation time could improve the accuracy of CEUS in discriminating malignant tumours from benign lesions. Materials and methods: 216 STT were studied: 40% benign lesions, 60% malignant tumours, 56% in the lower limbs. Seven CEUS perfusion patterns and three types of vascularisation (arterial-venous uptake, absence of uptake) were applied. Accuracy was evaluated by comparing imaging with the histological diagnosis. Univariate and multivariate analysis, Chi-square test and t-test for independent variables were applied; significance was set at p < 0.05 level, 95% computed CI. Results: CEUS pattern 6 (inhomogeneous perfusion), arterial uptake and location in the lower limb were associated with high risk of malignancy. CEUS pattern has PPV 77%, rapidity of vascularisation PPV 69%; location in the limbs is the most sensitive indicator, but NPV 52%, PPV 65%. The combination of CEUS-pattern and vascularisation has 74% PPV, 60% NPV, 70% sensitivity. No correlation with size and location in relation to the deep fascia was found. Conclusion: US with CEUS qualitative analysis could be an accurate technique to identify potentially malignant STT, for which second line imaging and biopsy are indicated in Referral Centers. Intense inhomogeneous enhancement with avascular areas and rapid vascularisation time could be useful in discriminating benign from malignant SST, overall when the lower limbs are involved.

  14. Growing indications for CEUS: The kidney, testis, lymph nodes, thyroid, prostate, and small bowel

    International Nuclear Information System (INIS)

    Cantisani, V.; Bertolotto, M.; Weskott, H.P.; Romanini, L.; Grazhdani, H.; Passamonti, M.; Drudi, F.M.; Malpassini, F.; Isidori, A.; Meloni, F.M.; Calliada, F.; D’Ambrosio, F.

    2015-01-01

    Highlights: • Contrast enhanced ultrasonography (CEUS) is increasingly used for non-hepatic applications. • There is a growing clinical use for a variety of pathologies of the kidney, testis, and small bowel. • Updated knowledge for proper use of CEUS in uncommon fields is provided. - Abstract: Contrast enhanced ultrasonography (CEUS) is increasingly used for non-hepatic applications as well, so that nearly all organs have been investigated. Among them, there is a growing clinical use for a variety of pathologies of the kidney, testis, and small bowel. The possibility to differentiate benign from malignant nodes in cancer patients has been investigated. A new application is in the detection of sentinel nodes after intradermal microbubble injection. The need to distinguish thyroid nodules eligible for fine needle aspiration cytology has led to the use of CEUS in thyroid examinations as well. The potential of CEUS for prostate cancer detection has been extensively investigated, with encouraging initial results. Early promise, however, has not been fulfilled. New perspective regards evaluation of the extent of prostate tissue devascularization following ablative treatments

  15. Growing indications for CEUS: The kidney, testis, lymph nodes, thyroid, prostate, and small bowel

    Energy Technology Data Exchange (ETDEWEB)

    Cantisani, V., E-mail: vito.cantisani@uniroma1.it [Department of Radiology, Anatomopathology and Oncology, “Sapienza” University of Rome (Italy); Bertolotto, M. [Department of Radiology, University of Trieste (Italy); Weskott, H.P. [Central Ultrasound Department, Klinikum Siloah , Hannover (Germany); Romanini, L. [University Hospital of Pavia (Italy); Grazhdani, H. [Department of Radiology, Anatomopathology and Oncology, “Sapienza” University of Rome (Italy); Passamonti, M. [Dipartimento di Scienze Radiologiche, Ospedale di Lodi (Italy); Drudi, F.M.; Malpassini, F. [Department of Radiology, Anatomopathology and Oncology, “Sapienza” University of Rome (Italy); Isidori, A. [Department of Experimental Medicine, “Sapienza” University of Rome, Rome (Italy); Meloni, F.M. [Dipartimento servizi diagnostici, Ospedale Valduce, Como (Italy); Calliada, F. [University Hospital of Pavia (Italy); D’Ambrosio, F. [Department of Radiology, Anatomopathology and Oncology, “Sapienza” University of Rome (Italy)

    2015-09-15

    Highlights: • Contrast enhanced ultrasonography (CEUS) is increasingly used for non-hepatic applications. • There is a growing clinical use for a variety of pathologies of the kidney, testis, and small bowel. • Updated knowledge for proper use of CEUS in uncommon fields is provided. - Abstract: Contrast enhanced ultrasonography (CEUS) is increasingly used for non-hepatic applications as well, so that nearly all organs have been investigated. Among them, there is a growing clinical use for a variety of pathologies of the kidney, testis, and small bowel. The possibility to differentiate benign from malignant nodes in cancer patients has been investigated. A new application is in the detection of sentinel nodes after intradermal microbubble injection. The need to distinguish thyroid nodules eligible for fine needle aspiration cytology has led to the use of CEUS in thyroid examinations as well. The potential of CEUS for prostate cancer detection has been extensively investigated, with encouraging initial results. Early promise, however, has not been fulfilled. New perspective regards evaluation of the extent of prostate tissue devascularization following ablative treatments.

  16. Perceptual Computing Aiding People in Making Subjective Judgments

    CERN Document Server

    Mendel, Jerry

    2010-01-01

    Explains for the first time how "computing with words" can aid in making subjective judgments. Lotfi Zadeh, the father of fuzzy logic, coined the phrase "computing with words" (CWW) to describe a methodology in which the objects of computation are words and propositions drawn from a natural language. Perceptual Computing explains how to implement CWW to aid in the important area of making subjective judgments, using a methodology that leads to an interactive device—a "Perceptual Computer"—that propagates random and linguistic uncertainties into the subjective judg

  17. CEUS: An essential component in a multimodality approach to small nodules in patients at high-risk for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hyun-Jung, E-mail: Hyun-Jung.jang@uhn.ca [Department of Medical Imaging, Toronto General Hospital, University of Toronto, 585 University Avenue, Toronto, Ontario M5G 2N2 (Canada); Kim, Tae Kyoung, E-mail: Taekyoung.Kim@uhn.ca [Department of Medical Imaging, Toronto General Hospital, University of Toronto, 585 University Avenue, Toronto, Ontario M5G 2N2 (Canada); Burns, Peter N, E-mail: burns@sri.utoronto.ca [Department of Imaging Research, University of Toronto, Sunnybrook Health Sciences centre, 2075 Bayview Avenue, Toronto ON M4 N 3M5 (Canada); Wilson, Stephanie R, E-mail: Stephanie.wilson@albertahealthservices.ca [Department of Radiology, University of Calgary, Foothills Medical Centre, 1403 29 Street NW, Calgary, AB T2R 1M5 (Canada)

    2015-09-15

    Highlights: • CEUS resolves hypervascular pseudolesions, frequent on CT and MR, from vascular shunts. • US has the advantage of showing a baseline nodule for characterization. • CEUS shows excellent sensitivity to contrast agents, providing superior arterial phase sensitivity. • Real-time CEUS performance shows optimally perfusion patterns of benign tumor nodules. • CEUS performed at surveillance detection of nodules is efficient and effective. - Abstract: Contrast-enhanced ultrasound (CEUS) plays an essential role in the evaluation of small nodules in livers at high-risk for hepatocellular carcinoma (HCC) and offers unique advantages over CT/MRI. These include the sensitive depiction of arterial hypervascularity of HCC, better demonstration of rapid washout for non-HCC malignancy as well as of very late washout of HCC. Visualization of early vascular filling patterns for benign hypervascular lesions is of indisputable value. A frequently uncounted benefit of CEUS includes the value of its performance following nodule detection at ultrasound surveillance, including one-stop exclusion of typical benignancy, preclusion of arterial pseudolesions shown on CT/MR, and the avoidance of miscorrelation of a nodule on surveillance and subsequent diagnostic imaging. Therefore, CEUS can effectively be used in the diagnostic algorithm for new liver nodules detected during HCC surveillance. Despite the fact that CEUS is actively used as a major diagnostic test for HCC in Asia, Europe, and Canada with increasing demands in clinical practice, CEUS is not included in the diagnostic tests for HCC in some major practice guidelines. In this manuscript, we focus on small nodules in patients at high-risk for HCC, and review some of the unique advantages of CEUS that contribute to lesion characterization and subsequent patient management, showing why CEUS should be an essential component of the diagnostic algorithm for HCC.

  18. Computer-aided voice training in higher education: participants ...

    African Journals Online (AJOL)

    The training of performance singing in a multi lingual, multi cultural educational context presents unique problems and requires inventive teaching strategies. Computer-aided training offers objective visual feedback of the voice production that can be implemented as a teaching aid in higher education. This article reports on ...

  19. Computer-Aided Corrosion Program Management

    Science.gov (United States)

    MacDowell, Louis

    2010-01-01

    This viewgraph presentation reviews Computer-Aided Corrosion Program Management at John F. Kennedy Space Center. The contents include: 1) Corrosion at the Kennedy Space Center (KSC); 2) Requirements and Objectives; 3) Program Description, Background and History; 4) Approach and Implementation; 5) Challenges; 6) Lessons Learned; 7) Successes and Benefits; and 8) Summary and Conclusions.

  20. Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Xu Huixiong; Chen Lida; Xie Xiaoyan; Xie Xiaohua; Xu Zuofeng; Liu Guangjian; Lin Manxia; Wang Zhu; Lu Mingde

    2010-01-01

    Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ultrasound, 89.5% (17/19) for CEUS, and 78.9% (15/19) for CECT (all P > 0.05 between every two groups). CEUS significantly improved the lesion conspicuity in comparison with CECT. CEUS and CECT made correct diagnoses in 30 (93.8%) and 25 (78.1%) lesions prior to pathological examination (P = 0.125). Conclusion: The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma shows hypoenhancement more likely on CEUS. CEUS and CECT lead to similar results in evaluating portal vein infiltration and diagnosis of this entity.

  1. Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huixiong, E-mail: xuhuixiong@hotmail.co [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Chen Lida; Xie Xiaoyan; Xie Xiaohua; Xu Zuofeng; Liu Guangjian; Lin Manxia; Wang Zhu [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Lu Mingde, E-mail: lumd@21cn.co [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China)

    2010-08-15

    Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ultrasound, 89.5% (17/19) for CEUS, and 78.9% (15/19) for CECT (all P > 0.05 between every two groups). CEUS significantly improved the lesion conspicuity in comparison with CECT. CEUS and CECT made correct diagnoses in 30 (93.8%) and 25 (78.1%) lesions prior to pathological examination (P = 0.125). Conclusion: The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma shows hypoenhancement more likely on CEUS. CEUS and CECT lead to similar results in evaluating portal vein infiltration and diagnosis of this entity.

  2. Students' perceptions of a multimedia computer-aided instruction ...

    African Journals Online (AJOL)

    Objective. To develop an interactive muttimedia-based computer-aided instruction (CAI) programme, to detennine its educational worth and efficacy in a multicuttural academic environment and to evaluate its usage by students with differing levels of computer literacy. Design. A prospective descriptive study evaluating ...

  3. Computer-aided engineering of semiconductor integrated circuits

    Science.gov (United States)

    Meindl, J. D.; Dutton, R. W.; Gibbons, J. F.; Helms, C. R.; Plummer, J. D.; Tiller, W. A.; Ho, C. P.; Saraswat, K. C.; Deal, B. E.; Kamins, T. I.

    1980-07-01

    Economical procurement of small quantities of high performance custom integrated circuits for military systems is impeded by inadequate process, device and circuit models that handicap low cost computer aided design. The principal objective of this program is to formulate physical models of fabrication processes, devices and circuits to allow total computer-aided design of custom large-scale integrated circuits. The basic areas under investigation are (1) thermal oxidation, (2) ion implantation and diffusion, (3) chemical vapor deposition of silicon and refractory metal silicides, (4) device simulation and analytic measurements. This report discusses the fourth year of the program.

  4. Correlation of thyroid papillary carcinoma CEUS characteristics with cancer cell proliferation and invasion

    Directory of Open Access Journals (Sweden)

    Jing Wan

    2017-04-01

    Full Text Available Objective: To study the correlation of thyroid papillary carcinoma CEUS characteristics with cancer cell proliferation and invasion. Methods: A total of 128 patients with thyroid papillary carcinoma who received surgical treatment in the hospital between May 2013 and May 2016 were collected, CEUS was used to make clear the peak intensity (PI and area under the curve (AUC of tumor tissue and surrounding normal tissue, and the median of PI and AUC was referred to further divide the patients into high PI group and low PI group as well as high AUC group and low AUC group, 64 cases in each group. Fluorescent quantitative PCR was used to determine proliferation and invasion gene mRNA expression in tumor tissues. Results: PI and AUC levels in tumor tissue were lower than those in surrounding normal tissue; proliferation genes EZH2, Livin, hTERT, HMGA1 and Wip1 mRNA expression of low PI group were higher than those of high PI group, and invasion gene Ki-67 mRNA expression was higher than that of high PI group while P53 and MRP-1 mRNA expression were lower than those of high PI group; proliferation genes EZH2, Livin, hTERT, HMGA1 and Wip1 mRNA expression of low AUC group were higher than those of high AUC group, and invasion gene Ki-67 mRNA expression was higher than that of high AUC group while P53 and MRP-1 mRNA expression were lower than those of high AUC group. Conclusion: Thyroid papillary carcinoma CEUS parameters PI and AUC levels can quantifiably reflect the cancer cell proliferation and invasion activity.

  5. Creation of system of computer-aided design for technological objects

    Science.gov (United States)

    Zubkova, T. M.; Tokareva, M. A.; Sultanov, N. Z.

    2018-05-01

    Due to the competition in the market of process equipment, its production should be flexible, retuning to various product configurations, raw materials and productivity, depending on the current market needs. This process is not possible without CAD (computer-aided design). The formation of CAD begins with planning. Synthesizing, analyzing, evaluating, converting operations, as well as visualization and decision-making operations, can be automated. Based on formal description of the design procedures, the design route in the form of an oriented graph is constructed. The decomposition of the design process, represented by the formalized description of the design procedures, makes it possible to make an informed choice of the CAD component for the solution of the task. The object-oriented approach allows us to consider the CAD as an independent system whose properties are inherited from the components. The first step determines the range of tasks to be performed by the system, and a set of components for their implementation. The second one is the configuration of the selected components. The interaction between the selected components is carried out using the CALS standards. The chosen CAD / CAE-oriented approach allows creating a single model, which is stored in the database of the subject area. Each of the integration stages is implemented as a separate functional block. The transformation of the CAD model into the model of the internal representation is realized by the block of searching for the geometric parameters of the technological machine, in which the XML-model of the construction is obtained on the basis of the feature method from the theory of image recognition. The configuration of integrated components is divided into three consecutive steps: configuring tasks, components, interfaces. The configuration of the components is realized using the theory of "soft computations" using the Mamdani fuzzy inference algorithm.

  6. Enhancement pattern of small hepatocellular carcinoma (HCC) at contrast-enhanced US (CEUS), MDCT, and MRI: Intermodality agreement and comparison of diagnostic sensitivity between 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines

    International Nuclear Information System (INIS)

    Furlan, Alessandro; Marin, Daniele; Cabassa, Paolo; Taibbi, Adele; Brunelli, Elena; Agnello, Francesco; Lagalla, Roberto; Brancatelli, Giuseppe

    2012-01-01

    Objective: To evaluate agreement between contrast-enhanced ultrasound (CEUS), multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) for the assessment of typical and atypical enhancement patterns of small hepatocellular carcinoma (HCC); and to compare diagnostic sensitivity of 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines. Materials and methods: Between January 2008 and December 2009, we included cirrhotic patients with newly diagnosed 10–20 mm HCC imaged at two contrast-enhanced imaging techniques among CEUS, MDCT, and MRI. Dynamic studies were reviewed by two radiologists to assess enhancement pattern. Percentage of cases with concordant findings and Cohen coefficient (k) were calculated. McNemar's test was used to compare sensitivity between 2005 and 2010 AASLD guidelines. Results: There were 91 patients (69 M; 22 F; mean age, 68 years) with 96 HCCs, studied with a combination of CEUS and MDCT (n = 59), CEUS and MRI (n = 26), or MDCT and MRI (n = 11). Intermodality agreement for assessment of tumor enhancement pattern was 67% (k = 0.294, P = 0.001). Typical enhancement pattern was detected coincidentally at two imaging modalities in 50 (52%) HCCs. Sensitivity for the diagnosis of HCC increased significantly using the 2010 AASLD (81/96 (84%) vs. 50/96 (52%), P < 0.001). Conclusions: Agreement between two imaging modalities for the detection of typical tumor enhancement pattern was reached in 52% of cases. The 2010 AASLD guidelines significantly increased the sensitivity for the diagnosis of HCC

  7. Computer-aided design and computer science technology

    Science.gov (United States)

    Fulton, R. E.; Voigt, S. J.

    1976-01-01

    A description is presented of computer-aided design requirements and the resulting computer science advances needed to support aerospace design. The aerospace design environment is examined, taking into account problems of data handling and aspects of computer hardware and software. The interactive terminal is normally the primary interface between the computer system and the engineering designer. Attention is given to user aids, interactive design, interactive computations, the characteristics of design information, data management requirements, hardware advancements, and computer science developments.

  8. Brain computed tomography of patients with HIV/AIDS before the ...

    African Journals Online (AJOL)

    Background: The objective is to study intracranial complications of HIV/AIDS using brain‑computed tomography in patients who presented with neurological features before the advent of subsidized HIV/AIDS treatment program with highly active antiretroviral therapy (HAART) in Nigeria. Materials and Methods: Retrospective ...

  9. Characterization of Focal Liver Lesions using CEUS and MRI with Liver-Specific Contrast Media: Experience of a Single Radiologic Center.

    Science.gov (United States)

    Beyer, Lukas Philipp; Wassermann, Florian; Pregler, Benedikt; Michalik, Katharina; Rennert, Janine; Wiesinger, Isabel; Stroszczynski, Christian; Wiggermann, Philipp; Jung, Ernst Michael

    2017-12-01

     The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL).  83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 - 6 MHz) after the injection of 1 - 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared.  The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2.  CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Differential diagnosis of gastric cancer and gastritis: the role of contrast-enhanced ultrasound (CEUS).

    Science.gov (United States)

    Xue, Heng; Ge, Hui-Yu; Miao, Li-Ying; Wang, Shu-Min; Zhao, Bo; Wang, Jin-Rui; Cui, Li-Gang

    2017-03-01

    To evaluate the diagnostic performance of contrast-enhanced ultrasound (CEUS) in differential diagnosis of gastric cancer and gastritis, with histological results as reference standard. From September 2011 to August 2014, 82 patients (50 males and 32 females; mean age ± SD, 59.5 ± 15.0 years; range 19-91 years) with gastric cancer or gastritis were included in this Ethics Committee-approved prospective study. Conventional ultrasonography (US) and CEUS were applied to distinguish the two lesions, and both qualitative and quantitative features were evaluated. Of the 82 histopathologic-proven lesions, 58 were cancer and 24 were gastritis. For US, the gastric wall stratification was not preserved in about one-third of cancer (21/58, 36.2%) compared with gastritis (0/24, 0%) (p gastritis (19/24, 79.2%, p gastritis. CEUS has the potential to make the diagnosis more accurate.

  11. Foreign Object in the Eye: First Aid

    Science.gov (United States)

    ... eye: First aid Foreign object in the eye: First aid By Mayo Clinic Staff If you get a foreign object in your eye Wash your hands ... et al., eds. American Medical Association Handbook of First Aid and Emergency Care. New York, N.Y.: Random ...

  12. Microwave processing of a dental ceramic used in computer-aided design/computer-aided manufacturing.

    Science.gov (United States)

    Pendola, Martin; Saha, Subrata

    2015-01-01

    Because of their favorable mechanical properties and natural esthetics, ceramics are widely used in restorative dentistry. The conventional ceramic sintering process required for their use is usually slow, however, and the equipment has an elevated energy consumption. Sintering processes that use microwaves have several advantages compared to regular sintering: shorter processing times, lower energy consumption, and the capacity for volumetric heating. The objective of this study was to test the mechanical properties of a dental ceramic used in computer-aided design/computer-aided manufacturing (CAD/CAM) after the specimens were processed with microwave hybrid sintering. Density, hardness, and bending strength were measured. When ceramic specimens were sintered with microwaves, the processing times were reduced and protocols were simplified. Hardness was improved almost 20% compared to regular sintering, and flexural strength measurements suggested that specimens were approximately 50% stronger than specimens sintered in a conventional system. Microwave hybrid sintering may preserve or improve the mechanical properties of dental ceramics designed for CAD/CAM processing systems, reducing processing and waiting times.

  13. [Computer-aided Prognosis for Breast Cancer Based on Hematoxylin & Eosin Histopathology Image].

    Science.gov (United States)

    Chen, Jiamei; Qu, Aiping; Liu, Wenlou; Wang, Linwei; Yuan, Jingping; Liu, Juan; Li, Yan

    2016-06-01

    Quantitatively analyzing hematoxylin &eosin(H&E)histopathology images is an emerging field attracting increasing attentions in recent years.This paper reviews the application of computer-aided image analysis in breast cancer prognosis.The traditional prognosis based on H&E histopathology image for breast cancer is firstly sketched,followed by a detailed description of the workflow of computer-aided prognosis including image acquisition,image preprocessing,regions of interest detection and object segmentation,feature extraction,and computer-aided prognosis.In the end,major technical challenges and future directions in this field are summarized.

  14. Computer-Aided Facilities Management Systems (CAFM).

    Science.gov (United States)

    Cyros, Kreon L.

    Computer-aided facilities management (CAFM) refers to a collection of software used with increasing frequency by facilities managers. The six major CAFM components are discussed with respect to their usefulness and popularity in facilities management applications: (1) computer-aided design; (2) computer-aided engineering; (3) decision support…

  15. [Value of contrast-enhanced ultrasound (CEUS) in the differential diagnosis between benign and malignant renal neoplasms].

    Science.gov (United States)

    Zhang, Sheng; Wang, Xiao-qing; Xin, Xiao-jie; Xu, Yong

    2013-05-01

    To investigate the value of contrast enhanced ultrasound (CEUS) imaging in the differential diagnosis between benign and malignant renal neoplasms. Two hundred and forty-five cases of renal space-occupying lesions confirmed by biopsy or surgical pathology were included in this study. The CEUS features of the renal space-occupying lesions, i.e., the enhancement degree, homogeneity of enhancement, washing-in and washing-out time and enhancement pattern, were retrospectively analyzed. There were 210 cases of malignant renal tumors and 35 cases of benign lesions. The CEUS modes of the malignant renal tumors included "quick in and quick out" 82 cases, "quick in and slow out" 64 cases, "slow in and quick out" 18 cases and "slow in and slow out" 46 cases; good enhancement 150 cases (71.4%) and inhomogeneous enhancement 180 cases (85.7%).Both the contrast agent filling defect area and solid component enhancement of solid-cystic tumors were important features of malignant renal tumors. In the 35 cases of benign lesions,the CEUS modes included "quick in and quick out" 4 cases, "quick in and slow out" 8 cases, "slow in and quick out" 10 cases and "slow in and slow out" 13 cases. Most of the benign tumors showed low enhancement 51.4% (18/35) and inhomogeneous enhancement 54.3% (19/35). There were significant differences between the malignant and benign renal neoplasms in CEUS mode, degree of enhancement and homogeneity of enhancement (P benign and malignant tumors were 77.1% and 83.8%, respectively, while the two-dimensional ultrasound diagnosis of benign and malignant tumors were 68.6% and 76.7%, respectively, with a significant difference (P benign and malignant renal lesions.

  16. Quantitative evaluation of muscle perfusion with CEUS and with MR

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Delorme, Stefan; Krix, Martin

    2007-01-01

    Functional imaging might increase the role of imaging in muscular diseases, since alterations of muscle morphology alone are not specific for a particular disease. Perfusion, i.e., the blood flow per tissue and time unit including capillary flow, is an important functional parameter. Pathological changes of skeletal muscle perfusion can be found in various clinical conditions, such as degenerative or inflammatory myopathies or peripheral arterial occlusive disease. This article reviews the theoretical basics of functional radiological techniques for assessing skeletal muscle perfusion and focuses on contrast-enhanced ultrasound (CEUS) and magnetic resonance imaging (MRI) techniques. Also, the applications of microvascular imaging, such as in detection of myositis and for discriminating myositis from other myopathies or evaluating peripheral arterial occlusive disease, are presented, and possible clinical indications are discussed. In conclusion, dedicated MR and CEUS methods are now available that visualize and quantify (patho-)physiologic information about microcirculation within skeletal muscles in vivo and hence establish a useful diagnostic tool for muscular diseases. (orig.)

  17. Quantitative evaluation of muscle perfusion with CEUS and with MR

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Marc-Andre; Delorme, Stefan [German Cancer Research Centre, Department of Radiology, Heidelberg (Germany); Krix, Martin [German Cancer Research Centre, Department of Radiology, Heidelberg (Germany); Bracco ALTANA Pharma GmbH, Konstanz (Germany)

    2007-10-15

    Functional imaging might increase the role of imaging in muscular diseases, since alterations of muscle morphology alone are not specific for a particular disease. Perfusion, i.e., the blood flow per tissue and time unit including capillary flow, is an important functional parameter. Pathological changes of skeletal muscle perfusion can be found in various clinical conditions, such as degenerative or inflammatory myopathies or peripheral arterial occlusive disease. This article reviews the theoretical basics of functional radiological techniques for assessing skeletal muscle perfusion and focuses on contrast-enhanced ultrasound (CEUS) and magnetic resonance imaging (MRI) techniques. Also, the applications of microvascular imaging, such as in detection of myositis and for discriminating myositis from other myopathies or evaluating peripheral arterial occlusive disease, are presented, and possible clinical indications are discussed. In conclusion, dedicated MR and CEUS methods are now available that visualize and quantify (patho-)physiologic information about microcirculation within skeletal muscles in vivo and hence establish a useful diagnostic tool for muscular diseases. (orig.)

  18. Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns

    NARCIS (Netherlands)

    Lohbauer, Ulrich; Belli, Renan; Cune, Marco S; Schepke, Ulf

    2017-01-01

    Today, a substantial part of the dental crown production uses computer-aided design and computer-aided manufacturing (CAD/CAM) technology. A recent step in restorative dentistry is the replacement of natural tooth structure with pre-polymerized and machined resin-based methacrylic polymers.

  19. Sonographic patterns of renal lymphoma in B-mode imaging and in contrast-enhanced ultrasound (CEUS)—A retrospective evaluation

    International Nuclear Information System (INIS)

    Trenker, C.; Neesse, A.; Görg, C.

    2015-01-01

    Introduction: Retrospective analysis of sonographic patterns of renal lymphoma in B-mode imaging and contrast-enhanced ultrasound (CEUS). Patients/methods: From January 2000 to June 2014, 27 patients with clinical or histologically confirmed renal lymphoma were examined with B-mode imaging, followed by CEUS in 8 cases. Results: In B-mode imaging renal lymphoma were hypoechoic in all 27 cases (100%). 9 patients (33.3%) had a bilateral, 18 (66.7%) patients had an unilateral lymphoma infiltration of the kidneys. 8 (29.6%) cases of small nodular, 5 (18.5%) cases of large nodular and 6 (22.2%) cases of perirenal lymphoma infiltration of the kidney were observed in B-mode imaging. Bulky-formation of renal lymphoma was detected in 6 (22.2%) patients and 2 (7.4%) patients had a diffuse lymphoma infiltration of the kidneys. In CEUS an arterial isoechoic enhancement was observed in 5 (62.5%)- and, an arterial hypoechoic enhancement was observed in 3 (37.5%) cases of renal lymphoma. A hypoechoic enhancement in the parenchymal phase was observed in 8 (100%) cases of renal lymphoma infiltration. Conclusion: In B-mode-imaging, nodular lymphoma infiltration of the kidneys is the most common of all renal lymphoma patterns in B-mode imaging. In CEUS, renal lymphoma presented an arterial iso- or hypoechoic enhancement, followed by a hypoechoic enhancement in the parenchymal phase. In regard to the differentiation of renal lymphoma to benign lesions of the kidney, CEUS may be helpful. However, the differentiation of renal lymphoma from other malignant lesions of the kidney like renal cell carcinoma is not feasible by CEUS

  20. A supervisor system for computer aided laser machining

    International Nuclear Information System (INIS)

    Mukherjee, J.K.

    1990-01-01

    Lasers achieve non divergent beam of short wavelength energy which can propagate through normal atmosphere with little divergence and can be focused on very fine points. The final high energy per unit area on target is highly localised and suitable for various types of machining at high speeds. The most notable factor is that this high energy spot can be located precisely using light-weight optical components. The laser-machining is very amenable to environmental conditions unlike electron beam and other techniques. Precision cutting and welding of nuclear materials in normal or non oxidising atmosphere can be done using this fairly easily. To achieve these objectives, development of a computer controlled laser machining system has been undertaken. The development project aims at building a computer aided machine with indegenous controller and medium power laser suitable for cutting, welding, and marking. This paper describes the integration of the various computer aided functions, spanning over the full range, from job-defining to final finished part-delivary, in computer aided laser machining. Various innovative features of the system that render it suitable for laser tool development as well as for special machining applications with user-friendliness have been covered. (author). 5 refs., 5 figs

  1. Features of Computer-Based Decision Aids: Systematic Review, Thematic Synthesis, and Meta-Analyses

    Science.gov (United States)

    Krömker, Dörthe; Meguerditchian, Ari N; Tamblyn, Robyn

    2016-01-01

    Background Patient information and education, such as decision aids, are gradually moving toward online, computer-based environments. Considerable research has been conducted to guide content and presentation of decision aids. However, given the relatively new shift to computer-based support, little attention has been given to how multimedia and interactivity can improve upon paper-based decision aids. Objective The first objective of this review was to summarize published literature into a proposed classification of features that have been integrated into computer-based decision aids. Building on this classification, the second objective was to assess whether integration of specific features was associated with higher-quality decision making. Methods Relevant studies were located by searching MEDLINE, Embase, CINAHL, and CENTRAL databases. The review identified studies that evaluated computer-based decision aids for adults faced with preference-sensitive medical decisions and reported quality of decision-making outcomes. A thematic synthesis was conducted to develop the classification of features. Subsequently, meta-analyses were conducted based on standardized mean differences (SMD) from randomized controlled trials (RCTs) that reported knowledge or decisional conflict. Further subgroup analyses compared pooled SMDs for decision aids that incorporated a specific feature to other computer-based decision aids that did not incorporate the feature, to assess whether specific features improved quality of decision making. Results Of 3541 unique publications, 58 studies met the target criteria and were included in the thematic synthesis. The synthesis identified six features: content control, tailoring, patient narratives, explicit values clarification, feedback, and social support. A subset of 26 RCTs from the thematic synthesis was used to conduct the meta-analyses. As expected, computer-based decision aids performed better than usual care or alternative aids; however

  2. Computer-Aided Manufacturing of 3D Workpieces

    OpenAIRE

    Cornelia Victoria Anghel Drugarin; Mihaela Dorica Stroia

    2017-01-01

    Computer-Aided Manufacturing (CAM) assumes to use dedicated software for controlling machine tools and similar devices in the process of workpieces manufacturing. CAM is, in fact, an application technology that uses computer software and machinery to simplify and automate manufacturing processes. CAM is the inheritor of computer-aided engineering (CAE) and is often used conjunctively with computer-aided design (CAD). Advanced CAM solutions are forthcoming and have a large ...

  3. Factors associated with initial incomplete ablation for benign thyroid nodules after radiofrequency ablation: First results of CEUS evaluation.

    Science.gov (United States)

    Zhao, Chong-Ke; Xu, Hui-Xiong; Lu, Feng; Sun, Li-Ping; He, Ya-Ping; Guo, Le-Hang; Li, Xiao-Long; Bo, Xiao-Wan; Yue, Wen-Wen

    2017-01-01

    To assess the factors associated with initial incomplete ablation (ICA) after radiofrequency ablation for benign thyroid nodules (BTNs). 69 BTNs (mean volume 6.35±5.66 ml, range 1.00-25.04 ml) confirmed by fine-needle aspiration cytology (FNAC) in fifty-four patients were treated with ultrasound-guided percutaneous radiofrequency ablation (RFA) and the local treatment efficacy was immediately assessed by intra-procedural contrast-enhanced ultrasound (CEUS). The RFA was performed with a bipolar electrode (CelonProSurge 150-T20, output power: 20 W). CEUS was performed with a second generation contrast agent under low acoustic power (i.e. coded phase inversion, CPI). Characteristics of clinical factors, findings on conventional gray-scale ultrasound, color-Doppler ultrasound, and CEUS were evaluated preoperatively. Factors associated with initial ICA and initial ICA patterns on CEUS were assessed. Volume reduction ratios (VRRs) of ICA nodules were compared with those with complete ablation (CA). The RFA procedures were accomplished with a mean ablation time and mean total energy deposition of 11.13±3.39 min (range, 5.38-22.13 min) and 12612±4466 J (range, 6310-26130 J) respectively. CEUS detected initial ICA in 21 of 69 (30.8%) BTNs and 16 (76.2%) of the 21 BTNs with initial ICA achieved CA after additional RFA, leading to a final CA rate of 92.8% (64/69). The factors associated with initial ICA were predominantly solid nodule, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound (all P 50% at the 6-month follow-up, among which 7 nodules (10.1%) had VRRs of >90%. There were significant differences in VRRs between ICA nodules and CA nodules at the 3- and 6-month follow-up (all P ultrasound. CEUS assists quick treatment response evaluation and facilitates subsequent additional RFA and final CA of the nodules. Nodules with CA achieve a better outcome in terms of VRR in comparison with

  4. Concept of development of integrated computer - based control system for 'Ukryttia' object

    International Nuclear Information System (INIS)

    Buyal'skij, V.M.; Maslov, V.P.

    2003-01-01

    The structural concept of Chernobyl NPP 'Ukryttia' Object's integrated computer - based control system development is presented on the basis of general concept of integrated Computer - based Control System (CCS) design process for organizing and technical management subjects.The concept is aimed at state-of-the-art architectural design technique application and allows using modern computer-aided facilities for functional model,information (logical and physical) models development,as well as for system object model under design

  5. Triphasic and epithelioid minimal fat renal angiomyolipoma and clear cell renal cell carcinoma: qualitative and quantitative CEUS characteristics and distinguishing features.

    Science.gov (United States)

    Lu, Qing; Li, Cui-xian; Huang, Bei-jian; Xue, Li-yun; Wang, Wen-ping

    2015-02-01

    To determine the contrast-enhanced ultrasonography (CEUS) characteristics of minimal fat renal angiomyolipoma (AML) (triphasic and epithelioid) and compare them to each other and to clear cell renal cell carcinoma (ccRCC) to explore their differential diagnostic clue. Qualitative and quantitative CEUS analyses were retrospectively conducted for epithelioid renal AMLs (EAMLs) (n = 15), triphasic minimal fat AMLs (TAMLs) (n = 25), and ccRCCs (n = 113). Enhancement patterns and features with CEUS were qualitatively evaluated. As for the quantitative parameters, rise times (RT), time to peak (TTP), and tumor-to-cortex enhancement ratio (TOC ratio) were compared among these renal tumor histotypes. No significant differences were detected on conventional ultrasound in the three histotypes of renal tumor. On qualitative CEUS analysis, centripetal enhancement in cortical phase (73.3% in EAMLs, 84.0% in TAMLs vs. 18.6% in ccRCCs, p qualitative and quantitative characteristics made no significant difference between EAMLs and TAMLs. In the differential diagnosis of EAMLs from TAMLs, pseudocapsule sign was valuable (40.0% in EAMLs vs. 0.0% in TAMLs, p 97.34% as the criteria to differentiate ccRCCs and EAMLs from TAMLs, the sensitivity and specificity were 80.0% and 87.5%, respectively. Qualitative and quantitative CEUS analyses are helpful in the differential diagnosis of ccRCCs, EAMLs, and TAMLs.

  6. Computer-Aided Video Differential Planimetry

    Science.gov (United States)

    Tobin, Michael; Djoleto, Ben D.

    1984-08-01

    THE VIDEO DIFFERENTIAL PLANIMETER (VDP)1 is a re-mote sensing instrument that can measure minute changes in the area of any object seen by an optical scanning system. The composite video waveforms obtained by scanning the object against a contrasting back-ground are amplified and shaped to yield a sequence of constant amplitude pulses whose polarity distinguishes the studied area from its background and whose varying widths reflect the dynamics of the viewed object. These pulses are passed through a relatively long time-constant capacitor-resistor circuit and are then fed into an integrator. The net integration voltage resulting from the most recent sequence of object-background time pulses is recorded and the integrator is returned to zero at the end of each video frame. If the object's area remains constant throughout the following frame, the integrator's summation will also remain constant. However, if the object's area varies, the positive and negative time pulses entering the integrator will change, and the integrator's summation will vary proportionately. The addition of a computer interface and a video recorder enhances the versatility and the resolving power of the VDP by permitting the repeated study and analysis of selected portions of the recorded data, thereby uncovering the major sources of the object's dynamics. Among the medical and biological procedures for which COMPUTER-AIDED VIDEO DIFFERENTIAL PLANIMETRY is suitable are Ophthalmoscopy, Endoscopy, Microscopy, Plethysmography, etc. A recent research study in Ophthalmoscopy2 will be cited to suggest a useful application of Video Differential Planimetry.

  7. The computer-aided design of rubber-metal products

    Directory of Open Access Journals (Sweden)

    Pavlo S. Shvets

    2015-12-01

    Full Text Available The important problem in design of rubber-metal products is the optimization of their mass without sacrificing of proportionality factor is in the limits of standard. Aim: The aim of this work is to improve the computer-aided systems by development and implementation of improved optimization method in rubber-metal CAD systems for designers based on the reverse optimization. Materials and Methods: The paper studies the matters of computer-aided structural design of technical composite products composed of anisotropic materials that are essentially different in properties. Results: The structure of CAD systems for designers solving the problems of such design is offered and the work principles of its subsystems are described. It is shown that complicated systems optimization in CAD systems must consider as restrictions the entitative connection between separate elements of these systems within the area of the optimizing arguments. Conclusions: The problem of the “reverse” optimization when objective functions are the connectivity area parameters is considered. In many cases, this allows receiving solutions that are more effective during the computer-aided design process. The developed CAD system for designers was used during the production of rubber-metal shock absorbers at the Odessa Rubber Technical Articles Plant. The positive technical and economic effect was obtained.

  8. Online LDA BASED brain-computer interface system to aid disabled people

    OpenAIRE

    Apdullah Yayık; Yakup Kutlu

    2017-01-01

    This paper aims to develop brain-computer interface system based on electroencephalography that can aid disabled people in daily life. The system relies on one of the most effective event-related potential wave, P300, which can be elicited by oddball paradigm. Developed application has a basic interaction tool that enables disabled people to convey their needs to other people selecting related objects. These objects pseudo-randomly flash in a visual interface on computer screen. The user must...

  9. Integrated computer aided design simulation and manufacture

    OpenAIRE

    Diko, Faek

    1989-01-01

    Computer Aided Design (CAD) and Computer Aided Manufacture (CAM) have been investigated and developed since twenty years as standalone systems. A large number of very powerful but independent packages have been developed for Computer Aided Design,Aanlysis and Manufacture. However, in most cases these packages have poor facility for communicating with other packages. Recently attempts have been made to develop integrated CAD/CAM systems and many software companies a...

  10. Computer Aided Measurement Laser (CAML): technique to quantify post-mastectomy lymphoedema

    International Nuclear Information System (INIS)

    Trombetta, Chiara; Abundo, Paolo; Felici, Antonella; Ljoka, Concetta; Foti, Calogero; Cori, Sandro Di; Rosato, Nicola

    2012-01-01

    Lymphoedema can be a side effect of cancer treatment. Eventhough several methods for assessing lymphoedema are used in clinical practice, an objective quantification of lymphoedema has been problematic. The aim of the study was to determine the objectivity, reliability and repeatability of the computer aided measurement laser (CAML) technique. CAML technique is based on computer aided design (CAD) methods and requires an infrared laser scanner. Measurements are scanned and the information describing size and shape of the limb allows to design the model by using the CAD software. The objectivity and repeatability was established in the beginning using a phantom. Consequently a group of subjects presenting post-breast cancer lymphoedema was evaluated using as a control the contralateral limb. Results confirmed that in clinical settings CAML technique is easy to perform, rapid and provides meaningful data for assessing lymphoedema. Future research will include a comparison of upper limb CAML technique between healthy subjects and patients with known lymphoedema.

  11. Computer aided detection of surgical retained foreign object for prevention

    International Nuclear Information System (INIS)

    Hadjiiski, Lubomir; Marentis, Theodore C.; Rondon, Lucas; Chan, Heang-Ping; Chaudhury, Amrita R.; Chronis, Nikolaos

    2015-01-01

    Purpose: Surgical retained foreign objects (RFOs) have significant morbidity and mortality. They are associated with approximately $1.5 × 10 9 annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. The authors address the RFO problem with two complementary technologies: a three-dimensional (3D) gossypiboma micro tag, the μTag that improves the visibility of RFOs on radiographs, and a computer aided detection (CAD) system that detects the μTag. It is desirable for the CAD system to operate in a high specificity mode in the operating room (OR) and function as a first reader for the surgeon. This allows for fast point of care results and seamless workflow integration. The CAD system can also operate in a high sensitivity mode as a second reader for the radiologist to ensure the highest possible detection accuracy. Methods: The 3D geometry of the μTag produces a similar two dimensional (2D) depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. The authors created a data set of 1800 cadaver images with the 3D μTag and other common man-made surgical objects positioned randomly. A total of 1061 cadaver images contained a single μTag and the remaining 739 were without μTag. A radiologist marked the location of the μTag using an in-house developed graphical user interface. The data set was partitioned into three independent subsets: a training set, a validation set, and a test set, consisting of 540, 560, and 700 images, respectively. A CAD system with modules that included preprocessing μTag enhancement, labeling, segmentation, feature analysis, classification, and detection was developed. The CAD system was developed using the training and the validation sets. Results: On the training set, the CAD achieved 81.5% sensitivity with 0.014 false positives (FPs) per image in a high specificity mode for the surgeons in the OR and 96

  12. Computer-Aided Qualitative Data Analysis with Word

    Directory of Open Access Journals (Sweden)

    Bruno Nideröst

    2002-05-01

    Full Text Available Despite some fragmentary references in the literature about qualitative methods, it is fairly unknown that Word can be successfully used for computer-aided Qualitative Data Analyses (QDA. Based on several Word standard operations, elementary QDA functions such as sorting data, code-and-retrieve and frequency counts can be realized. Word is particularly interesting for those users who wish to have first experiences with computer-aided analysis before investing time and money in a specialized QDA Program. The well-known standard software could also be an option for those qualitative researchers who usually work with word processing but have certain reservations towards computer-aided analysis. The following article deals with the most important requirements and options of Word for computer-aided QDA. URN: urn:nbn:de:0114-fqs0202225

  13. Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT)

    Science.gov (United States)

    Consortium and Partners | Transportation Research | NREL Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Consortium and Partners Computer-Aided Engineering for Electric -Drive Vehicle Batteries (CAEBAT) Consortium and Partners The Computer-Aided Engineering for Electric

  14. Features of Computer-Based Decision Aids: Systematic Review, Thematic Synthesis, and Meta-Analyses.

    Science.gov (United States)

    Syrowatka, Ania; Krömker, Dörthe; Meguerditchian, Ari N; Tamblyn, Robyn

    2016-01-26

    Patient information and education, such as decision aids, are gradually moving toward online, computer-based environments. Considerable research has been conducted to guide content and presentation of decision aids. However, given the relatively new shift to computer-based support, little attention has been given to how multimedia and interactivity can improve upon paper-based decision aids. The first objective of this review was to summarize published literature into a proposed classification of features that have been integrated into computer-based decision aids. Building on this classification, the second objective was to assess whether integration of specific features was associated with higher-quality decision making. Relevant studies were located by searching MEDLINE, Embase, CINAHL, and CENTRAL databases. The review identified studies that evaluated computer-based decision aids for adults faced with preference-sensitive medical decisions and reported quality of decision-making outcomes. A thematic synthesis was conducted to develop the classification of features. Subsequently, meta-analyses were conducted based on standardized mean differences (SMD) from randomized controlled trials (RCTs) that reported knowledge or decisional conflict. Further subgroup analyses compared pooled SMDs for decision aids that incorporated a specific feature to other computer-based decision aids that did not incorporate the feature, to assess whether specific features improved quality of decision making. Of 3541 unique publications, 58 studies met the target criteria and were included in the thematic synthesis. The synthesis identified six features: content control, tailoring, patient narratives, explicit values clarification, feedback, and social support. A subset of 26 RCTs from the thematic synthesis was used to conduct the meta-analyses. As expected, computer-based decision aids performed better than usual care or alternative aids; however, some features performed better than

  15. [A computer-aided image diagnosis and study system].

    Science.gov (United States)

    Li, Zhangyong; Xie, Zhengxiang

    2004-08-01

    The revolution in information processing, particularly the digitizing of medicine, has changed the medical study, work and management. This paper reports a method to design a system for computer-aided image diagnosis and study. Combined with some good idea of graph-text system and picture archives communicate system (PACS), the system was realized and used for "prescription through computer", "managing images" and "reading images under computer and helping the diagnosis". Also typical examples were constructed in a database and used to teach the beginners. The system was developed by the visual developing tools based on object oriented programming (OOP) and was carried into operation on the Windows 9X platform. The system possesses friendly man-machine interface.

  16. Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) |

    Science.gov (United States)

    Transportation Research | NREL Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Graphic of a 24-cell (bottom). Images: Courtesy of EC Power NREL's work on the U.S. Department of Energy Computer-Aided

  17. Computer aided design

    International Nuclear Information System (INIS)

    Barache, J.M.; Beltranda, G.; Blanc, P.

    1987-01-01

    In order to ensure that the data transmitted to the managment system is of the required quality and consistent with the general control command protocols, computer aided design (CAD) was employed for level N4. One describes the use of CAD for the control system of N4 [fr

  18. [Clinical skills and outcomes of chair-side computer aided design and computer aided manufacture system].

    Science.gov (United States)

    Yu, Q

    2018-04-09

    Computer aided design and computer aided manufacture (CAD/CAM) technology is a kind of oral digital system which is applied to clinical diagnosis and treatment. It overturns the traditional pattern, and provides a solution to restore defect tooth quickly and efficiently. In this paper we mainly discuss the clinical skills of chair-side CAD/CAM system, including tooth preparation, digital impression, the three-dimensional design of prosthesis, numerical control machining, clinical bonding and so on, and review the outcomes of several common kinds of materials at the same time.

  19. An esthetics rehabilitation with computer-aided design/ computer-aided manufacturing technology.

    Science.gov (United States)

    Mazaro, Josá Vitor Quinelli; de Mello, Caroline Cantieri; Zavanelli, Adriana Cristina; Santiago, Joel Ferreira; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza

    2014-07-01

    This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.

  20. Cultural objects as objects: materiality, urban space, and the interpretation of AIDS campaigns in Accra, Ghana.

    Science.gov (United States)

    McDonnell, Terence E

    2010-05-01

    AIDS media lead unexpected lives once distributed through urban space: billboards fade, posters go missing, bumper stickers travel to other cities. The materiality of AIDS campaign objects and of the urban settings in which they are displayed structures how the public interprets their messages. Ethnographic observation of AIDS media in situ and interview data reveal how the materiality of objects and places shapes the availability of AIDS knowledge in Accra, Ghana. Significantly for AIDS organizations, these material conditions often systematically obstruct access to AIDS knowledge for particular groups. Attending to materiality rethinks how scholars assess the cultural power of media.

  1. Computer-aided engineering in High Energy Physics

    International Nuclear Information System (INIS)

    Bachy, G.; Hauviller, C.; Messerli, R.; Mottier, M.

    1988-01-01

    Computing, standard tool for a long time in the High Energy Physics community, is being slowly introduced at CERN in the mechanical engineering field. The first major application was structural analysis followed by Computer-Aided Design (CAD). Development work is now progressing towards Computer-Aided Engineering around a powerful data base. This paper gives examples of the power of this approach applied to engineering for accelerators and detectors

  2. SMART USE OF COMPUTER-AIDED SPERM ANALYSIS (CASA) TO CHARACTERIZE SPERM MOTION

    Science.gov (United States)

    Computer-aided sperm analysis (CASA) has evolved over the past fifteen years to provide an objective, practical means of measuring and characterizing the velocity and parttern of sperm motion. CASA instruments use video frame-grabber boards to capture multiple images of spermato...

  3. Comparison of Contrast-Enhanced Ultrasound and Computed Tomography in Classifying Endoleaks After Endovascular Treatment of Abdominal Aorta Aneurysms: Preliminary Experience

    International Nuclear Information System (INIS)

    Carrafiello, Gianpaolo; Lagana, Domenico; Recaldini, Chiara; Mangini, Monica; Bertolotti, Elena; Caronno, Roberto; Tozzi, Matteo; Piffaretti, Gabriele; Annibale Genovese, Eugenio; Fugazzola, Carlo

    2006-01-01

    The purpose of the study was to assess the effectiveness of contrast-enhanced ultrasonography (CEUS) in endoleak classification after endovascular treatment of an abdominal aortic aneurysm compared to computed tomography angiography (CTA). From May 2001 to April 2003, 10 patients with endoleaks already detected by CTA underwent CEUS with Sonovue (registered) to confirm the CTA classification or to reclassify the endoleak. In three conflicting cases, the patients were also studied with conventional angiography. CEUS confirmed the CTA classification in seven cases (type II endoleaks). Two CTA type III endoleaks were classified as type II using CEUS and one CTA type II endoleak was classified as type I by CEUS. Regarding the cases with discordant classification, conventional angiography confirmed the ultrasound classification. Additionally, CEUS documented the origin of type II endoleaks in all cases. After CEUS reclassification of endoleaks, a significant change in patient management occurred in three cases. CEUS allows a better attribution of the origin of the endoleak, as it shows the flow in real time. CEUS is more specific than CTA in endoleak classification and gives more accurate information in therapeutic planning

  4. Perfusion quantification in contrast-enhanced ultrasound (CEUS)--ready for research projects and routine clinical use.

    Science.gov (United States)

    Tranquart, F; Mercier, L; Frinking, P; Gaud, E; Arditi, M

    2012-07-01

    With contrast-enhanced ultrasound (CEUS) now established as a valuable imaging modality for many applications, a more specific demand has recently emerged for quantifying perfusion and using measured parameters as objective indicators for various disease states. However, CEUS perfusion quantification remains challenging and is not well integrated in daily clinical practice. The development of VueBox™ alleviates existing limitations and enables quantification in a standardized way. VueBox™ operates as an off-line software application, after dynamic contrast-enhanced ultrasound (DCE-US) is performed. It enables linearization of DICOM clips, assessment of perfusion using patented curve-fitting models, and generation of parametric images by synthesizing perfusion information at the pixel level using color coding. VueBox™ is compatible with most of the available ultrasound platforms (nonlinear contrast-enabled), has the ability to process both bolus and disruption-replenishment kinetics loops, allows analysis results and their context to be saved, and generates analysis reports automatically. Specific features have been added to VueBox™, such as fully automatic in-plane motion compensation and an easy-to-use clip editor. Processing time has been reduced as a result of parallel programming optimized for multi-core processors. A long list of perfusion parameters is available for each of the two administration modes to address all possible demands currently reported in the literature for diagnosis or treatment monitoring. In conclusion, VueBox™ is a valid and robust quantification tool to be used for standardizing perfusion quantification and to improve the reproducibility of results across centers. © Georg Thieme Verlag KG Stuttgart · New York.

  5. New Paradigms for Computer Aids to Invention.

    Science.gov (United States)

    Langston, M. Diane

    Many people are interested in computer aids to rhetorical invention and want to know how to evaluate an invention aid, what the criteria are for a good one, and how to assess the trade-offs involved in buying one product or another. The frame of reference for this evaluation is an "old paradigm," which treats the computer as if it were…

  6. Quantitative Assessment of Free Flap Viability with CEUS Using an Integrated Perfusion Software.

    Science.gov (United States)

    Geis, S; Klein, S; Prantl, L; Dolderer, J; Lamby, P; Jung, E-M

    2015-12-01

    New treatment strategies in oncology and trauma surgery lead to an increasing demand for soft tissue reconstruction with free tissue transfer. In previous studies, CEUS was proven to detect early flap failure. The aim of this study was to detect and quantify vascular disturbances after free flap transplantation using a fast integrated perfusion software tool. From 2011 to 2013, 33 patients were examined by one experienced radiologist using CEUS after a bolus injection of 1-2.4 ml of SonoVue(®). Flap perfusion was analysed qualitatively regarding contrast defects or delayed wash-in. Additionally, an integrated semi-quantitative analysis using time-intensity curve analysis (TIC) was performed. TIC analysis of the transplant was conducted on a centimetre-by-centimetre basis up to a penetration depth of 4 cm. The 2 perfusion parameters "Time to PEAK" and "Area under the Curve" were compared in patients without complications vs. patients with minor complications or complete flap loss to figure out significant differences. TtoPk is given in seconds (s) and Area is given in relative units (rU) Results: A regular postoperative process was observed in 26 (79%) patients. In contrast, 5 (15%) patients with partial superficial flap necrosis, 1 patient (3%) with complete flap loss and 1 patient (3%) with haematoma were observed. TtoPk revealed no significant differences, whereas Area revealed significantly lower perfusion values in the corresponding areas in patients with complications. The critical threshold for sufficient flap perfusion was set below 150 rU. In conclusion, CEUS is a mobile and cost-effective opportunity to quantify tissue perfusion and can even be used almost without any restrictions in multi-morbid patients with renal and hepatic failure. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Computer-Aided Modeling of Lipid Processing Technology

    DEFF Research Database (Denmark)

    Diaz Tovar, Carlos Axel

    2011-01-01

    increase along with growing interest in biofuels, the oleochemical industry faces in the upcoming years major challenges in terms of design and development of better products and more sustainable processes to make them. Computer-aided methods and tools for process synthesis, modeling and simulation...... are widely used for design, analysis, and optimization of processes in the chemical and petrochemical industries. These computer-aided tools have helped the chemical industry to evolve beyond commodities toward specialty chemicals and ‘consumer oriented chemicals based products’. Unfortunately...... to develop systematic computer-aided methods (property models) and tools (database) related to the prediction of the necessary physical properties suitable for design and analysis of processes employing lipid technologies. The methods and tools include: the development of a lipid-database (CAPEC...

  8. Intelligent Support for a Computer Aided Design Optimisation Cycle

    OpenAIRE

    B. Dolšak; M. Novak; J. Kaljun

    2006-01-01

    It is becoming more and more evident that  adding intelligence  to existing computer aids, such as computer aided design systems, can lead to significant improvements in the effective and reliable performance of various engineering tasks, including design optimisation. This paper presents three different intelligent modules to be applied within a computer aided design optimisation cycle to enable more intelligent and less experience-dependent design performance. 

  9. A computer-aided framework for development, identification andmanagement of physiologically-based pharmacokinetic models

    DEFF Research Database (Denmark)

    Heitzig, Martina; Linninger, Andreas; Sin, Gürkan

    2014-01-01

    The objective of this work is the development of a generic computer-aided modelling framework to support the development of physiologically-based pharmacokinetic models thereby increasing the efficiency and quality of the modelling process. In particular, the framework systematizes the modelling...

  10. Contrast-enhanced ultrasound vs multidetector-computed tomography for detecting liver metastases in colorectal cancer: a prospective, blinded, patient-by-patient analysis

    DEFF Research Database (Denmark)

    Rafaelsen, S R; Jakobsen, A

    2011-01-01

    This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer.......This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer....

  11. Computer Aided Solvent Selection and Design Framework

    DEFF Research Database (Denmark)

    Mitrofanov, Igor; Conte, Elisa; Abildskov, Jens

    and computer-aided tools and methods for property prediction and computer-aided molecular design (CAMD) principles. This framework is applicable for solvent selection and design in product design as well as process design. The first module of the framework is dedicated to the solvent selection and design...... in terms of: physical and chemical properties (solvent-pure properties); Environment, Health and Safety (EHS) characteristic (solvent-EHS properties); operational properties (solvent–solute properties). 3. Performing the search. The search step consists of two stages. The first is a generation and property...... identification of solvent candidates using special software ProCAMD and ProPred, which are the implementations of computer-aided molecular techniques. The second consists of assigning the RS-indices following the reaction–solvent and then consulting the known solvent database and identifying the set of solvents...

  12. Computer Aided Drug Design: Success and Limitations.

    Science.gov (United States)

    Baig, Mohammad Hassan; Ahmad, Khurshid; Roy, Sudeep; Ashraf, Jalaluddin Mohammad; Adil, Mohd; Siddiqui, Mohammad Haris; Khan, Saif; Kamal, Mohammad Amjad; Provazník, Ivo; Choi, Inho

    2016-01-01

    Over the last few decades, computer-aided drug design has emerged as a powerful technique playing a crucial role in the development of new drug molecules. Structure-based drug design and ligand-based drug design are two methods commonly used in computer-aided drug design. In this article, we discuss the theory behind both methods, as well as their successful applications and limitations. To accomplish this, we reviewed structure based and ligand based virtual screening processes. Molecular dynamics simulation, which has become one of the most influential tool for prediction of the conformation of small molecules and changes in their conformation within the biological target, has also been taken into account. Finally, we discuss the principles and concepts of molecular docking, pharmacophores and other methods used in computer-aided drug design.

  13. Indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography: Assessment of the additional diagnostic value of contrast-enhanced ultrasound in the non-cirrhotic liver

    International Nuclear Information System (INIS)

    Quaia, Emilio; De Paoli, Luca; Angileri, Roberta; Cabibbo, Biagio; Cova, Maria Assunta

    2014-01-01

    Objective: To assess the additional diagnostic value of contrast-enhanced ultrasound (CEUS) in the characterization of indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography (CT). Methods: Fifty-five solid hepatic lesions (1–4 cm in diameter) in 46 non-cirrhotic patients (26 female, 20 male; age ± SD, 55 ± 10 years) underwent CEUS after being detected on contrast-enhanced CT which was considered as non-diagnostic after on-site analysis. Two blinded independent readers assessed CT and CEUS scans and were asked to classify retrospectively each lesion as a malignant or benign based on reference diagnostic criteria for the different hepatic lesion histotypes. Diagnostic accuracy and confidence (area – A z – under ROC curve) were assessed by using gadobenate dimeglumine-enhanced magnetic resonance (MR) imaging (n = 30 lesions), histology (n = 7 lesions), or US follow-up (n = 18 lesions) as the reference standards. Results: Final diagnoses included 29 hemangiomas, 3 focal nodular hyperplasias, 1 hepatocellular adenoma, and 22 metastases. The additional review of CEUS after CT images improved significantly (P < .05) the diagnostic accuracy (before vs after CEUS review = 49% [20/55] vs 89% [49/55] – reader 1 and 43% [24/55] vs 92% [51/55] – reader 2) and confidence (A z , 95% Confidence Intervals before vs after CEUS review = .773 [.652–.895] vs .997 [.987–1] – reader 1 and .831 [.724–.938] vs .998 [.992–1] – reader 2). Conclusions: CEUS improved the characterization of indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced CT by identifying some specific contrast enhancement patterns.

  14. Dual-scan technique for the customization of zirconia computer-aided design/computer-aided manufacturing frameworks.

    Science.gov (United States)

    Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes

    2013-09-01

    The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.

  15. Computer aided product design

    DEFF Research Database (Denmark)

    Constantinou, Leonidas; Bagherpour, Khosrow; Gani, Rafiqul

    1996-01-01

    A general methodology for Computer Aided Product Design (CAPD) with specified property constraints which is capable of solving a large range of problems is presented. The methodology employs the group contribution approach, generates acyclic, cyclic and aromatic compounds of various degrees......-liquid equilibria (LLE), solid-liquid equilibria (SLE) and gas solubility. Finally, a computer program based on the extended methodology has been developed and the results from five case studies highlighting various features of the methodology are presented....

  16. Remote handling prospects. Computer aided remote handling

    International Nuclear Information System (INIS)

    Vertut, J.

    1984-01-01

    Mechanical manipulators, electrical control manipulators and computer aided manipulators were successively developed. The aim of computer aided manipulators is the realization of complex or tricky job in adverse environment but man is required for non routine work or for situation in evolution. French effort is developed in the frame of the project automation and advanced robotics and new problems have to be solved particularly at the interface man/machine [fr

  17. Computer Aided Mathematics

    DEFF Research Database (Denmark)

    Sinclair, Robert

    1998-01-01

    Course notes of a PhD course held in 1998. The central idea is to introduce students to computational mathematics using object oriented programming in C++.......Course notes of a PhD course held in 1998. The central idea is to introduce students to computational mathematics using object oriented programming in C++....

  18. Computer aided design for the nuclear industry

    International Nuclear Information System (INIS)

    Basson, Keith

    1986-01-01

    The paper concerns the new computer aided design (CAD) centre for the United Kingdom nuclear industry, and its applications. A description of the CAD system is given, including the current projects at the CAD centre. Typical applications of the 3D CAD plant based models, stress analysis studies, and the extraction of data from CAD drawings to produce associated documentation, are all described. Future developments using computer aided design systems are also considered. (U.K.)

  19. Guidelines and good clinical practice recommendations for Contrast Enhanced Ultrasound (CEUS) in the liver - update 2012

    DEFF Research Database (Denmark)

    Claudon, Michel; Dietrich, Christoph F; Choi, Byung Ihn

    2013-01-01

    Initially, a set of guidelines for the use of ultrasound contrast agents was published in 2004 dealing only with liver applications. A second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some...... Medizin/European Journal of Ultrasound for EFSUMB). These guidelines and recommendations provide general advice on the use of all currently clinically available ultrasound contrast agents (UCA). They are intended to create standard protocols for the use and administration of UCA in liver applications...... non-liver applications. Time has moved on, and the need for international guidelines on the use of CEUS in the liver has become apparent. The present document describes the third iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS) using contrast specific imaging...

  20. Torsional strength of computer-aided design/computer-aided manufacturing-fabricated esthetic orthodontic brackets.

    Science.gov (United States)

    Alrejaye, Najla; Pober, Richard; Giordano Ii, Russell

    2017-01-01

    To fabricate orthodontic brackets from esthetic materials and determine their fracture resistance during archwire torsion. Computer-aided design/computer-aided manufacturing technology (Cerec inLab, Sirona) was used to mill brackets with a 0.018 × 0.025-inch slot. Materials used were Paradigm MZ100 and Lava Ultimate resin composite (3M ESPE), Mark II feldspathic porcelain (Vita Zahnfabrik), and In-Ceram YZ zirconia (Vita Zahnfabrik). Ten brackets of each material were subjected to torque by a 0.018 × 0.025-inch stainless steel archwire (G&H) using a specially designed apparatus. The average moments and degrees of torsion necessary to fracture the brackets were determined and compared with those of commercially available alumina brackets, Mystique MB (Dentsply GAC). The YZ brackets were statistically significantly stronger than any other tested material in their resistance to torsion (P brackets. Resistance of MZ100 and Lava Ultimate composite resin brackets to archwire torsion was comparable to commercially available alumina ceramic brackets.

  1. Server-Aided Verification Signature with Privacy for Mobile Computing

    Directory of Open Access Journals (Sweden)

    Lingling Xu

    2015-01-01

    Full Text Available With the development of wireless technology, much data communication and processing has been conducted in mobile devices with wireless connection. As we know that the mobile devices will always be resource-poor relative to static ones though they will improve in absolute ability, therefore, they cannot process some expensive computational tasks due to the constrained computational resources. According to this problem, server-aided computing has been studied in which the power-constrained mobile devices can outsource some expensive computation to a server with powerful resources in order to reduce their computational load. However, in existing server-aided verification signature schemes, the server can learn some information about the message-signature pair to be verified, which is undesirable especially when the message includes some secret information. In this paper, we mainly study the server-aided verification signatures with privacy in which the message-signature pair to be verified can be protected from the server. Two definitions of privacy for server-aided verification signatures are presented under collusion attacks between the server and the signer. Then based on existing signatures, two concrete server-aided verification signature schemes with privacy are proposed which are both proved secure.

  2. On the Value of Computer-aided Instruction: Thoughts after Teaching Sales Writing in a Computer Classroom.

    Science.gov (United States)

    Hagge, John

    1986-01-01

    Focuses on problems encountered with computer-aided writing instruction. Discusses conflicts caused by the computer classroom concept, some general paradoxes and ethical implications of computer-aided instruction. (EL)

  3. Computer-aided system for cryogenic research facilities

    International Nuclear Information System (INIS)

    Gerasimov, V.P.; Zhelamsky, M.V.; Mozin, I.V.; Repin, S.S.

    1994-01-01

    A computer-aided system is developed for the more effective choice and optimization of the design and manufacturing technologies of the superconductor for the magnet system of the International Thermonuclear Experimental Reactor (ITER) with the aim to ensure the superconductor certification. The computer-aided system provides acquisition, processing, storage and display of data describing the proceeding tests, the detection of any parameter deviations and their analysis. Besides, it generates commands for the equipment switch off in emergency situations. ((orig.))

  4. Analysis of Achilles tendon vascularity with second generation Contrast-Enhanced Ultrasound (CEUS)

    OpenAIRE

    Genovese , Eugenio; Ronga , Mario; Recaldini , Chiara; Fontana , Federico; Callegari , Leonardo; Fugazzola , Carlo

    2011-01-01

    Abstract Purpose: To compare morphological and power Doppler features of the Achilles tendon and Contrast-Enhanced Ultrasound (CEUS) behaviour between asymptomatic athletes and athletes who had undergone surgery for repair of an Achilles tendon rupture. Materials and Methods: 24 athletes were divided in two groups (A and B). Group A included 14 patients with a median age of 32 years (range 27 to 47 years) who had undergone surgical repair for unilateral Achilles tendon ...

  5. Computer-aided dispatch--traffic management center field operational test final detailed test plan : WSDOT deployment

    Science.gov (United States)

    2003-10-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...

  6. Post-operative monitoring of tissue transfers: advantages using contrast enhanced ultrasound (CEUS) and contrast enhanced MRI (ceMRI) with dynamic perfusion analysis?

    Science.gov (United States)

    Lamby, P; Prantl, L; Fellner, C; Geis, S; Jung, E M

    2011-01-01

    The immediate evaluation of microvascular tissue flaps with respect to microcirculation after transplantation is crucial for optimal monitoring and outcome. The purpose of our investigation was to evaluate the clinical value of contrast-enhanced ultrasound (CEUS) and contrast-enhanced MRI (ceMRI) for monitoring the integrity of tissue flaps in plastic surgery. To this end, we investigated 10 patients (47 ± 16 a) between postoperative day 7 and 14 who underwent flap surgery in order to cover tissue defects in various body regions. For CEUS we utilized the GE LOGIQ E9 equipped with a linear transducer (6-9 MHz). After application of 2.4 ml SonoVue, the tissue perfusion was detected in Low MI-Technique (MI present, both technologies provide an optimal assessment of perfusion in cutaneous, subcutaneous and muscle tissue layers, whereby the detection of fatty tissue perfusion is currently more easily detected using CEUS compared to ceMRI.

  7. Computer-aided diagnosis of leukoencephalopathy in children treated for acute lymphoblastic leukemia

    Science.gov (United States)

    Glass, John O.; Li, Chin-Shang; Helton, Kathleen J.; Reddick, Wilburn E.

    2005-04-01

    The purpose of this study was to use objective quantitative MR imaging methods to develop a computer-aided diagnosis tool to differentiate white matter (WM) hyperintensities as either leukoencephalopathy (LE) or normal maturational processes in children treated for acute lymphoblastic leukemia with intravenous high dose methotrexate. A combined imaging set consisting of T1, T2, PD, and FLAIR MR images and WM, gray matter, and cerebrospinal fluid a priori maps from a spatially normalized atlas were analyzed with a neural network segmentation based on a Kohonen Self-Organizing Map. Segmented regions were manually classified to identify the most hyperintense WM region and the normal appearing genu region. Signal intensity differences normalized to the genu within each examination were generated for two time points in 203 children. An unsupervised hierarchical clustering algorithm with the agglomeration method of McQuitty was used to divide data from the first examination into normal appearing or LE groups. A C-support vector machine (C-SVM) was then trained on the first examination data and used to classify the data from the second examination. The overall accuracy of the computer-aided detection tool was 83.5% (299/358) with sensitivity to normal WM of 86.9% (199/229) and specificity to LE of 77.5% (100/129) when compared to the readings of two expert observers. These results suggest that subtle therapy-induced leukoencephalopathy can be objectively and reproducibly detected in children treated for cancer using this computer-aided detection approach based on relative differences in quantitative signal intensity measures normalized within each examination.

  8. CAT -- computer aided testing for resonant inspection

    International Nuclear Information System (INIS)

    Foley, David K.

    1998-01-01

    Application of computer technology relates to inspection and quality control. The computer aided testing (CAT) can be used to analyze various NDT technologies, such as eddy current, ultrasonics, and resonant inspection

  9. Software For Computer-Aided Design Of Control Systems

    Science.gov (United States)

    Wette, Matthew

    1994-01-01

    Computer Aided Engineering System (CAESY) software developed to provide means to evaluate methods for dealing with users' needs in computer-aided design of control systems. Interpreter program for performing engineering calculations. Incorporates features of both Ada and MATLAB. Designed to be flexible and powerful. Includes internally defined functions, procedures and provides for definition of functions and procedures by user. Written in C language.

  10. Computer aided drug design

    Science.gov (United States)

    Jain, A.

    2017-08-01

    Computer based method can help in discovery of leads and can potentially eliminate chemical synthesis and screening of many irrelevant compounds, and in this way, it save time as well as cost. Molecular modeling systems are powerful tools for building, visualizing, analyzing and storing models of complex molecular structure that can help to interpretate structure activity relationship. The use of various techniques of molecular mechanics and dynamics and software in Computer aided drug design along with statistics analysis is powerful tool for the medicinal chemistry to synthesis therapeutic and effective drugs with minimum side effect.

  11. The computer-aided design of a servo system as a multiple-criteria decision problem

    NARCIS (Netherlands)

    Udink ten Cate, A.J.

    1986-01-01

    This paper treats the selection of controller gains of a servo system as a multiple-criteria decision problem. In contrast to the usual optimization-based approaches to computer-aided design, inequality constraints are included in the problem as unconstrained objectives. This considerably simplifies

  12. Computer-aided dispatch--traffic management center field operational test final test plans : state of Utah

    Science.gov (United States)

    2004-01-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...

  13. COMPUTER-AIDED DATA ACQUISITION FOR COMBUSTION EXPERIMENTS

    Science.gov (United States)

    The article describes the use of computer-aided data acquisition techniques to aid the research program of the Combustion Research Branch (CRB) of the U.S. EPA's Air and Energy Engineering Research Laboratory (AEERL) in Research Triangle Park, NC, in particular on CRB's bench-sca...

  14. Evaluation of tumor response to intra-arterial chemoembolization of hepatocellular carcinoma: Comparison of contrast-enhanced ultrasound with multiphase computed tomography.

    Science.gov (United States)

    Paul, S B; Dhamija, E; Gamanagatti, S R; Sreenivas, V; Yadav, D P; Jain, S; Shalimar; Acharya, S K

    2017-03-01

    To compare the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) with that of multiphase computed tomography (CT) in the evaluation of tumor response to transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). Fifty patients (41 men, 9 women; mean age, 53 years±12.5 [SD]) with a total of 70 HCCs (mean size, 5cm±3 [SD]) were evaluated. Post-TACE therapeutic assessment of HCC was done at 4 weeks. Patients with TACE done earlier and reporting with suspicion for recurrence were also included. Patients with hepatic masses seen on ultrasound were enrolled and subjected to CEUS, multiphase CT and magnetic resonance imaging (MRI). Hyperenhancing area at the tumor site on arterial phase of CEUS/multiphase CT/MRI was termed as residual disease (RD), the patterns of which were described on CEUS. Diagnostic accuracies of CEUS and MPCT were compared to that of MRI that was used as the reference standard. CEUS detected RD in 43/70 HCCs (61%). RD had a heterogeneous pattern in 22/43 HCCs (51%). Sensitivities of CEUS and multiphase CT were 94% (34/36; 95% CI: 81-99%) and 50% (18/36; 95% CI: 33-67%) respectively. Significant difference in sensitivity was found between CEUS and multiphase CT (P=0.0001). CEUS and multiphase CT had 100% specificity (95% CI: 83-100%). CEUS is a useful technique for detecting RD in HCC after TACE. For long term surveillance, CEUS should be complemented with multiphase CT/MRI for a comprehensive evaluation. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  15. Computer aided safety analysis

    International Nuclear Information System (INIS)

    1988-05-01

    The document reproduces 20 selected papers from the 38 papers presented at the Technical Committee/Workshop on Computer Aided Safety Analysis organized by the IAEA in co-operation with the Institute of Atomic Energy in Otwock-Swierk, Poland on 25-29 May 1987. A separate abstract was prepared for each of these 20 technical papers. Refs, figs and tabs

  16. Online LDA BASED brain-computer interface system to aid disabled people

    Directory of Open Access Journals (Sweden)

    Apdullah Yayık

    2017-06-01

    Full Text Available This paper aims to develop brain-computer interface system based on electroencephalography that can aid disabled people in daily life. The system relies on one of the most effective event-related potential wave, P300, which can be elicited by oddball paradigm. Developed application has a basic interaction tool that enables disabled people to convey their needs to other people selecting related objects. These objects pseudo-randomly flash in a visual interface on computer screen. The user must focus on related object to convey desired needs. The system can convey desired needs correctly by detecting P300 wave in acquired 14-channel EEG signal and classifying using linear discriminant analysis classifier just in 15 seconds. Experiments have been carried out on 19 volunteers to validate developed BCI system. As a result, accuracy rate of 90.83% is achieved in online performance.

  17. Adhesive Bonding to Computer-aided Design/ Computer-aided Manufacturing Esthetic Dental Materials: An Overview.

    Science.gov (United States)

    Awad, Mohamed Moustafa; Alqahtani, H; Al-Mudahi, A; Murayshed, M S; Alrahlah, A; Bhandi, Shilpa H

    2017-07-01

    To review the adhesive bonding to different computer-aided design/computer-aided manufacturing (CAD/CAM) esthetic restorative materials. The use of CAD/CAM esthetic restorative materials has gained popularity in recent years. Several CAD/ CAM esthetic restorative materials are commercially available. Adhesive bonding is a major determinant of success of CAD/ CAM restorations. Review result: An account of the currently available bonding strategies are discussed with their rationale in various CAD/ CAM materials. Different surface treatment methods as well as adhesion promoters can be used to achieve reliable bonding of CAD/CAM restorative materials. Selection of bonding strategy to such material is determined based on its composition. Further evidence is required to evaluate the effect of new surface treatment methods, such as nonthermal atmospheric plasma and self-etching ceramic primer on bonding to different dental ceramics. An understanding of the currently available bonding strategies to CA/CAM materials can help the clinician to select the most indicated system for each category of materials.

  18. [Key points for esthetic rehabilitation of anterior teeth using chair-side computer aided design and computer aided manufacture technique].

    Science.gov (United States)

    Yang, J; Feng, H L

    2018-04-09

    With the rapid development of the chair-side computer aided design and computer aided manufacture (CAD/CAM) technology, its accuracy and operability of have been greatly improved in recent years. Chair-side CAD/CAM system may produce all kinds of indirect restorations, and has the advantages of rapid, accurate and stable production. It has become the future development direction of Stomatology. This paper describes the clinical application of the chair-side CAD/CAM technology for anterior aesthetic restorations from the aspects of shade and shape.

  19. Multimedia Image Technology and Computer Aided Manufacturing Engineering Analysis

    Science.gov (United States)

    Nan, Song

    2018-03-01

    Since the reform and opening up, with the continuous development of science and technology in China, more and more advanced science and technology have emerged under the trend of diversification. Multimedia imaging technology, for example, has a significant and positive impact on computer aided manufacturing engineering in China. From the perspective of scientific and technological advancement and development, the multimedia image technology has a very positive influence on the application and development of computer-aided manufacturing engineering, whether in function or function play. Therefore, this paper mainly starts from the concept of multimedia image technology to analyze the application of multimedia image technology in computer aided manufacturing engineering.

  20. Integrated computer-aided design using minicomputers

    Science.gov (United States)

    Storaasli, O. O.

    1980-01-01

    Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), a highly interactive software, has been implemented on minicomputers at the NASA Langley Research Center. CAD/CAM software integrates many formerly fragmented programs and procedures into one cohesive system; it also includes finite element modeling and analysis, and has been interfaced via a computer network to a relational data base management system and offline plotting devices on mainframe computers. The CAD/CAM software system requires interactive graphics terminals operating at a minimum of 4800 bits/sec transfer rate to a computer. The system is portable and introduces 'interactive graphics', which permits the creation and modification of models interactively. The CAD/CAM system has already produced designs for a large area space platform, a national transonic facility fan blade, and a laminar flow control wind tunnel model. Besides the design/drafting element analysis capability, CAD/CAM provides options to produce an automatic program tooling code to drive a numerically controlled (N/C) machine. Reductions in time for design, engineering, drawing, finite element modeling, and N/C machining will benefit productivity through reduced costs, fewer errors, and a wider range of configuration.

  1. Correction of facial and mandibular asymmetry using a computer aided design/computer aided manufacturing prefabricated titanium implant.

    Science.gov (United States)

    Watson, Jason; Hatamleh, Muhanad; Alwahadni, Ahed; Srinivasan, Dilip

    2014-05-01

    Patients with significant craniofacial asymmetry may have functional problems associated with their occlusion and aesthetic concerns related to the imbalance in soft and hard tissue profiles. This report details a case of facial asymmetry secondary to left mandible angle deficiency due to undergoing previous radiotherapy. We describe the correction of the bony deformity using computer aided design/computer aided manufacturing custom-made titanium onlay using novel direct metal laser sintering. The direct metal laser sintering onlay proved a very accurate operative fit and showed a good aesthetic correction of the bony defect with no reported complications postoperatively. It is a useful low-morbidity technique, and there is no resorption or associated donor-site complications.

  2. Contrast Enhanced Ultrasound of the Kidneys: What Is It Capable of?

    Directory of Open Access Journals (Sweden)

    Demosthenes D. Cokkinos

    2013-01-01

    Full Text Available One of the many imaging uses of contrast enhanced ultrasound (CEUS is studying a wide variety of kidney pathology, due to its ability to detect microvascular blood flow in real time without affecting renal function. CEUS enables dynamic assessment and quantification of microvascularisation up to capillary perfusion. The objective of this paper is to briefly refresh basic knowledge of ultrasound (US contrast agents’ physical properties, to study technical details of CEUS scanning in the kidneys, and to review the commonest renal indications for CEUS, with imaging examples in comparison to baseline unenhanced US and computed tomography when performed. Safety matters and limitations of CEUS of the kidneys are also discussed.

  3. Computer aided plant engineering: An analysis and suggestions for computer use

    International Nuclear Information System (INIS)

    Leinemann, K.

    1979-09-01

    To get indications to and boundary conditions for computer use in plant engineering, an analysis of the engineering process was done. The structure of plant engineering is represented by a network of substaks and subsets of data which are to be manipulated. Main tool for integration of CAD-subsystems in plant engineering should be a central database which is described by characteristical requirements and a possible simple conceptual schema. The main features of an interactive system for computer aided plant engineering are shortly illustrated by two examples. The analysis leads to the conclusion, that an interactive graphic system for manipulation of net-like structured data, usable for various subtasks, should be the base for computer aided plant engineering. (orig.) [de

  4. Computer-Aided Detection of Kidney Tumor on Abdominal Computed Tomography Scans

    International Nuclear Information System (INIS)

    Kim, D.Y.; Park, J.W.

    2004-01-01

    Purpose: To implement a computer-aided detection system for kidney segmentation and kidney tumor detection on abdominal computed tomography (CT) scans. Material and Methods: Abdominal CT images were digitized with a film digitizer, and a gray-level threshold method was used to segment the kidney. Based on texture analysis performed on sample images of kidney tumors, a portion of the kidney tumor was selected as seed region for start point of the region-growing process. The average and standard deviations were used to detect the kidney tumor. Starting at the detected seed region, the region-growing method was used to segment the kidney tumor with intensity values used as an acceptance criterion for a homogeneous test. This test was performed to merge the neighboring region as kidney tumor boundary. These methods were applied on 156 transverse images of 12 cases of kidney tumors scanned using a G.E. Hispeed CT scanner and digitized with a Lumisys LS-40 film digitizer. Results: The computer-aided detection system resulted in a kidney tumor detection sensitivity of 85% and no false-positive findings. Conclusion: This computer-aided detection scheme was useful for kidney tumor detection and gave the characteristics of detected kidney tumors

  5. Reports on the utilization of the grant-in-aid for computational programs (the fiscal year 1989)

    International Nuclear Information System (INIS)

    1990-05-01

    In the Research Center for Nuclear Physics, Osaka University, the grant-in-aid for computational programs has been set up since 1976, which has supported mostly the theoretical computation in the field of nuclear physics. The subjects of 50,000 yen or more are invited every year as the object of the grant-in-aid, and adopted according to the opinion of referees and through the discussion by the ad hoc committee. When this grant-in-aid was utilized, it is decided to present two reports after the use was finished, that is, the simple report in the definite format and the detailed report on the contents of computation. In the latter, the abstract in English, the results obtained by the computation and the explanation of the physical contents, the newly developed points and the difficulty in the computational techniques and the method of its solution, the names of Subroutines and Functions used for the computation, their functions and the block diagram and so on are included. In this book, 23 detailed reports of the utilization in fiscal year 1989 are collected. (K.I.)

  6. To the problem of reliability standardization in computer-aided manufacturing at NPP units

    International Nuclear Information System (INIS)

    Yastrebenetskij, M.A.; Shvyryaev, Yu.V.; Spektor, L.I.; Nikonenko, I.V.

    1989-01-01

    The problems of reliability standardization in computer-aided manufacturing of NPP units considering the following approaches: computer-aided manufacturing of NPP units as a part of automated technological complex; computer-aided manufacturing of NPP units as multi-functional system, are analyzed. Selection of the composition of reliability indeces for computer-aided manufacturing of NPP units for each of the approaches considered is substantiated

  7. Variation in semen parameters derived from computer-aided semen analysis, within donors and between donors

    NARCIS (Netherlands)

    Wijchman, JG; De Wolf, BTHM; Graaff, R; Arts, EGJM

    2001-01-01

    The development of computer-aided semen analysis (CASA) has made it possible to study sperm motility characteristics objectively and longitudinally. In this 2-year study of 8 sperm donors, we used CASA to measure 7 semen parameters (concentration, percentage of motile spermatozoa, curvilinear

  8. The Impact of Machine Translation and Computer-aided Translation on Translators

    Science.gov (United States)

    Peng, Hao

    2018-03-01

    Under the context of globalization, communications between countries and cultures are becoming increasingly frequent, which make it imperative to use some techniques to help translate. This paper is to explore the influence of computer-aided translation on translators, which is derived from the field of the computer-aided translation (CAT) and machine translation (MT). Followed by an introduction to the development of machine and computer-aided translation, it then depicts the technologies practicable to translators, which are trying to analyze the demand of designing the computer-aided translation so far in translation practice, and optimize the designation of computer-aided translation techniques, and analyze its operability in translation. The findings underline the advantages and disadvantages of MT and CAT tools, and the serviceability and future development of MT and CAT technologies. Finally, this thesis probes into the impact of these new technologies on translators in hope that more translators and translation researchers can learn to use such tools to improve their productivity.

  9. Computer aided instrumented Charpy test applied dynamic fracture toughness evaluation system

    International Nuclear Information System (INIS)

    Kobayashi, Toshiro; Niinomi, Mitsuo

    1986-01-01

    Micro computer aided data treatment system and personal computer aided data analysis system were applied to the traditional instrumented Charpy impact test system. The analysis of Charpy absorbed energy (E i , E p , E t ) and load (P y , P m ), and the evaluation of dynamic toughness through whole fracture process, i.e. J Id , J R curve and T mat was examined using newly developed computer aided instrumented Charpy impact test system. E i , E p , E t , P y and P m were effectively analyzed using moving average method and printed out automatically by micro computer aided data treatment system. J Id , J R curve and T mat could be measured by stop block test method. Then, J Id , J R curve and T mat were effectively estimated using compliance changing rate method and key curve method on the load-load point displacement curve of single fatigue cracked specimen by personal computer aided data analysis system. (author)

  10. Computer-Aided Parts Estimation

    OpenAIRE

    Cunningham, Adam; Smart, Robert

    1993-01-01

    In 1991, Ford Motor Company began deployment of CAPE (computer-aided parts estimating system), a highly advanced knowledge-based system designed to generate, evaluate, and cost automotive part manufacturing plans. cape is engineered on an innovative, extensible, declarative process-planning and estimating knowledge representation language, which underpins the cape kernel architecture. Many manufacturing processes have been modeled to date, but eventually every significant process in motor veh...

  11. Computer aided instruction in the nuclear training classroom

    International Nuclear Information System (INIS)

    McFarlane, A.F.

    1983-01-01

    The objectives formulated for introducing computer aided instruction into the nuclear training programme are discussed and the process of comparative evaluation which was followed to arrive at a preferred system is described. Three points must be remembered. First it is unlikely that specialized training will benefit from any cost reduction since the total manpower invested can seldom be applied over enough students to represent an overall cost saving when compared with conventional classroom methods. Second it is unnecessary to present on a video screen material which would be better left in its original printed textbook or manual. Thirdly care must be taken not to assume too much or too little prior knowledge in the student. In nuclear training, concentrated information transfer is required in a short period of time. Carefully planned and executed computer assisted instruction can improve teaching effectiveness and provide a welcome alternative to conventional classroom instruction. (U.K.)

  12. Prerequisites for Computer-Aided Cognitive Rehabilitation.

    Science.gov (United States)

    Legrand, Colette

    1989-01-01

    This paper describes computer-aided cognitive rehabilitation for mentally deficient persons. It lists motor, cognitive, emotional, and educational prerequisites to such rehabilitation and states advantages and disadvantages in using the prerequisites. (JDD)

  13. Computer-aided instruction system

    International Nuclear Information System (INIS)

    Teneze, Jean Claude

    1968-01-01

    This research thesis addresses the use of teleprocessing and time sharing by the RAX IBM system and the possibility to introduce a dialog with the machine to develop an application in which the computer plays the role of a teacher for different pupils at the same time. Two operating modes are thus exploited: a teacher-mode and a pupil-mode. The developed CAI (computer-aided instruction) system comprises a checker to check the course syntax in teacher-mode, a translator to trans-code the course written in teacher-mode into a form which can be processes by the execution programme, and the execution programme which presents the course in pupil-mode

  14. Computer-aided-design-model-assisted absolute three-dimensional shape measurement.

    Science.gov (United States)

    Li, Beiwen; Bell, Tyler; Zhang, Song

    2017-08-20

    Conventional three-dimensional (3D) shape measurement methods are typically generic to all types of objects. Yet, for many measurement conditions, such a level of generality is inessential when having the preknowledge of the object geometry. This paper introduces a novel adaptive algorithm for absolute 3D shape measurement with the assistance of the object computer-aided-design (CAD) model. The proposed algorithm includes the following major steps: (1) export the 3D point cloud data from the CAD model; (2) transform the CAD model into the camera perspective; (3) obtain a wrapped phase map from three phase-shifted fringe images; and (4) retrieve absolute phase and 3D geometry assisted by the CAD model. We demonstrate that if object CAD models are available, such an algorithm is efficient in recovering absolute 3D geometries of both simple and complex objects with only three phase-shifted fringe images.

  15. Computer-aided modeling framework for efficient model development, analysis and identification

    DEFF Research Database (Denmark)

    Heitzig, Martina; Sin, Gürkan; Sales Cruz, Mauricio

    2011-01-01

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy, and water. This trend is set to continue due to the substantial benefits computer-aided...... methods introduce. The key prerequisite of computer-aided product-process engineering is however the availability of models of different types, forms, and application modes. The development of the models required for the systems under investigation tends to be a challenging and time-consuming task....... The methodology has been implemented into a computer-aided modeling framework, which combines expert skills, tools, and database connections that are required for the different steps of the model development work-flow with the goal to increase the efficiency of the modeling process. The framework has two main...

  16. Computer-aided power systems analysis

    CERN Document Server

    Kusic, George

    2008-01-01

    Computer applications yield more insight into system behavior than is possible by using hand calculations on system elements. Computer-Aided Power Systems Analysis: Second Edition is a state-of-the-art presentation of basic principles and software for power systems in steady-state operation. Originally published in 1985, this revised edition explores power systems from the point of view of the central control facility. It covers the elements of transmission networks, bus reference frame, network fault and contingency calculations, power flow on transmission networks, generator base power setti

  17. Computer-aided modeling for efficient and innovative product-process engineering

    DEFF Research Database (Denmark)

    Heitzig, Martina

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy and water. This trend is set to continue due to the substantial benefits computer...... in chemical and biochemical engineering have been solved to illustrate the application of the generic modelling methodology, the computeraided modelling framework and the developed software tool.......-aided methods provide. The key prerequisite of computer-aided productprocess engineering is however the availability of models of different types, forms and application modes. The development of the models required for the systems under investigation tends to be a challenging, time-consuming and therefore cost...

  18. Geometric and computer-aided spline hob modeling

    Science.gov (United States)

    Brailov, I. G.; Myasoedova, T. M.; Panchuk, K. L.; Krysova, I. V.; Rogoza, YU A.

    2018-03-01

    The paper considers acquiring the spline hob geometric model. The objective of the research is the development of a mathematical model of spline hob for spline shaft machining. The structure of the spline hob is described taking into consideration the motion in parameters of the machine tool system of cutting edge positioning and orientation. Computer-aided study is performed with the use of CAD and on the basis of 3D modeling methods. Vector representation of cutting edge geometry is accepted as the principal method of spline hob mathematical model development. The paper defines the correlations described by parametric vector functions representing helical cutting edges designed for spline shaft machining with consideration for helical movement in two dimensions. An application for acquiring the 3D model of spline hob is developed on the basis of AutoLISP for AutoCAD environment. The application presents the opportunity for the use of the acquired model for milling process imitation. An example of evaluation, analytical representation and computer modeling of the proposed geometrical model is reviewed. In the mentioned example, a calculation of key spline hob parameters assuring the capability of hobbing a spline shaft of standard design is performed. The polygonal and solid spline hob 3D models are acquired by the use of imitational computer modeling.

  19. Possible Computer Vision Systems and Automated or Computer-Aided Edging and Trimming

    Science.gov (United States)

    Philip A. Araman

    1990-01-01

    This paper discusses research which is underway to help our industry reduce costs, increase product volume and value recovery, and market more accurately graded and described products. The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or computer controlled processing. This paper...

  20. Evaluation of computer-aided detection and diagnosis systems.

    Science.gov (United States)

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in

  1. Computational modelling of the impact of AIDS on business.

    Science.gov (United States)

    Matthews, Alan P

    2007-07-01

    An overview of computational modelling of the impact of AIDS on business in South Africa, with a detailed description of the AIDS Projection Model (APM) for companies, developed by the author, and suggestions for further work. Computational modelling of the impact of AIDS on business in South Africa requires modelling of the epidemic as a whole, and of its impact on a company. This paper gives an overview of epidemiological modelling, with an introduction to the Actuarial Society of South Africa (ASSA) model, the most widely used such model for South Africa. The APM produces projections of HIV prevalence, new infections, and AIDS mortality on a company, based on the anonymous HIV testing of company employees, and projections from the ASSA model. A smoothed statistical model of the prevalence test data is computed, and then the ASSA model projection for each category of employees is adjusted so that it matches the measured prevalence in the year of testing. FURTHER WORK: Further techniques that could be developed are microsimulation (representing individuals in the computer), scenario planning for testing strategies, and models for the business environment, such as models of entire sectors, and mapping of HIV prevalence in time and space, based on workplace and community data.

  2. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams

    Science.gov (United States)

    Bennamoun, Mohammed

    2014-01-01

    In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses. PMID:24817888

  3. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams

    Directory of Open Access Journals (Sweden)

    Jaafar Abduo

    2014-01-01

    Full Text Available In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses.

  4. Vascular tissue engineering by computer-aided laser micromachining.

    Science.gov (United States)

    Doraiswamy, Anand; Narayan, Roger J

    2010-04-28

    Many conventional technologies for fabricating tissue engineering scaffolds are not suitable for fabricating scaffolds with patient-specific attributes. For example, many conventional technologies for fabricating tissue engineering scaffolds do not provide control over overall scaffold geometry or over cell position within the scaffold. In this study, the use of computer-aided laser micromachining to create scaffolds for vascular tissue networks was investigated. Computer-aided laser micromachining was used to construct patterned surfaces in agarose or in silicon, which were used for differential adherence and growth of cells into vascular tissue networks. Concentric three-ring structures were fabricated on agarose hydrogel substrates, in which the inner ring contained human aortic endothelial cells, the middle ring contained HA587 human elastin and the outer ring contained human aortic vascular smooth muscle cells. Basement membrane matrix containing vascular endothelial growth factor and heparin was to promote proliferation of human aortic endothelial cells within the vascular tissue networks. Computer-aided laser micromachining provides a unique approach to fabricate small-diameter blood vessels for bypass surgery as well as other artificial tissues with complex geometries.

  5. The software developing method for multichannel computer-aided system for physical experiments control, realized by resources of national instruments LabVIEW instrumental package

    International Nuclear Information System (INIS)

    Gorskaya, E.A.; Samojlov, V.N.

    1999-01-01

    This work is describing the method of developing the computer-aided control system in integrated environment of LabVIEW. Using the object-oriented design of complex systems, the hypothetical model for methods of developing the software for computer-aided system for physical experiments control was constructed. Within the framework of that model architecture solutions and implementations of suggested method were described. (author)

  6. Computer aided safety analysis 1989

    International Nuclear Information System (INIS)

    1990-04-01

    The meeting was conducted in a workshop style, to encourage involvement of all participants during the discussions. Forty-five (45) experts from 19 countries, plus 22 experts from the GDR participated in the meeting. A list of participants can be found at the end of this volume. Forty-two (42) papers were presented and discussed during the meeting. Additionally an open discussion was held on the possible directions of the IAEA programme on Computer Aided Safety Analysis. A summary of the conclusions of these discussions is presented in the publication. The remainder of this proceedings volume comprises the transcript of selected technical papers (22) presented in the meeting. It is the intention of the IAEA that the publication of these proceedings will extend the benefits of the discussions held during the meeting to a larger audience throughout the world. The Technical Committee/Workshop on Computer Aided Safety Analysis was organized by the IAEA in cooperation with the National Board for Safety and Radiological Protection (SAAS) of the German Democratic Republic in Berlin. The purpose of the meeting was to provide an opportunity for discussions on experiences in the use of computer codes used for safety analysis of nuclear power plants. In particular it was intended to provide a forum for exchange of information among experts using computer codes for safety analysis under the Technical Cooperation Programme on Safety of WWER Type Reactors (RER/9/004) and other experts throughout the world. A separate abstract was prepared for each of the 22 selected papers. Refs, figs tabs and pictures

  7. [The automatic iris map overlap technology in computer-aided iridiagnosis].

    Science.gov (United States)

    He, Jia-feng; Ye, Hu-nian; Ye, Miao-yuan

    2002-11-01

    In the paper, iridology and computer-aided iridiagnosis technologies are briefly introduced and the extraction method of the collarette contour is then investigated. The iris map can be overlapped on the original iris image based on collarette contour extraction. The research on collarette contour extraction and iris map overlap is of great importance to computer-aided iridiagnosis technologies.

  8. Computer-aided system design

    Science.gov (United States)

    Walker, Carrie K.

    1991-01-01

    A technique has been developed for combining features of a systems architecture design and assessment tool and a software development tool. This technique reduces simulation development time and expands simulation detail. The Architecture Design and Assessment System (ADAS), developed at the Research Triangle Institute, is a set of computer-assisted engineering tools for the design and analysis of computer systems. The ADAS system is based on directed graph concepts and supports the synthesis and analysis of software algorithms mapped to candidate hardware implementations. Greater simulation detail is provided by the ADAS functional simulator. With the functional simulator, programs written in either Ada or C can be used to provide a detailed description of graph nodes. A Computer-Aided Software Engineering tool developed at the Charles Stark Draper Laboratory (CSDL CASE) automatically generates Ada or C code from engineering block diagram specifications designed with an interactive graphical interface. A technique to use the tools together has been developed, which further automates the design process.

  9. Metalloporphyrin catalysts for oxygen reduction developed using computer-aided molecular design

    Energy Technology Data Exchange (ETDEWEB)

    Ryba, G.N.; Hobbs, J.D.; Shelnutt, J.A. [and others

    1996-04-01

    The objective of this project is the development of a new class of metalloporphyrin materials used as catalsyts for use in fuel cell applications. The metalloporphyrins are excellent candidates for use as catalysts at both the anode and cathode. The catalysts reduce oxygen in 1 M potassium hydroxide, as well as in 2 M sulfuric acid. Covalent attachment to carbon supports is being investigated. The computer-aided molecular design is an iterative process, in which experimental results feed back into the design of future catalysts.

  10. Collaborative research on fluidization employing computer-aided particle tracking

    International Nuclear Information System (INIS)

    Chen, M.M.

    1990-01-01

    The objective of this work is to obtain unique, fundamental information on fluidization dynamics over a wide range of flow regimes using a Transportable Computer-Aided Particle Tracking Apparatus (TCAPTA). The contractor will design and fabricate a transportable version of the Computer-Aided Particle Tracking Facility (CAPTF) he has previously developed. The contractor will install and operate the (TCAPTA) at the METC fluidization research facilities. Quantitative data on particle motion will be obtained and reduced. The data will be used to provide needed information for modeling of bed dynamics, and prediction of bed performance, including erosion. A radioactive tracer particle, identical in size shape and mass to the bed particles under study, is mixed in the bed. The radiation emitted by the tracer particle, monitored continuously by 16 scintillation detectors, allows its position to be determined as a function of time. Stochastic mixing processes intrinsic to fluidization further cause the particle to travel to all active regions of the bed, thus sampling the motion in these regions. After a long test run to insure that a sufficient sampling have been acquired, time-differentiation and other statistical processing will then yield the mean velocity distribution, the fluctuating velocity distribution, many types of auto- and cross correlations, as well as mean fluxes, including the mean momentum fluxes due to random motion, which represent the kinetic contributions to the mean stress tensor

  11. Age-related differences in skeletal muscle microvascular response to exercise as detected by contrast-enhanced ultrasound (CEUS).

    Science.gov (United States)

    Hildebrandt, Wulf; Schwarzbach, Hans; Pardun, Anita; Hannemann, Lena; Bogs, Björn; König, Alexander M; Mahnken, Andreas H; Hildebrandt, Olaf; Koehler, Ulrich; Kinscherf, Ralf

    2017-01-01

    Aging involves reductions in exercise total limb blood flow and exercise capacity. We hypothesized that this may involve early age-related impairments of skeletal muscle microvascular responsiveness as previously reported for insulin but not for exercise stimuli in humans. Using an isometric exercise model, we studied the effect of age on contrast-enhanced ultrasound (CEUS) parameters, i.e. microvascular blood volume (MBV), flow velocity (MFV) and blood flow (MBF) calculated from replenishment of Sonovue contrast-agent microbubbles after their destruction. CEUS was applied to the vastus lateralis (VLat) and intermedius (VInt) muscle in 15 middle-aged (MA, 43.6±1.5 years) and 11 young (YG, 24.1±0.6 years) healthy males before, during, and after 2 min of isometric knee extension at 15% of peak torque (PT). In addition, total leg blood flow as recorded by femoral artery Doppler-flow. Moreover, fiber-type-specific and overall capillarisation as well as fiber composition were additionally assessed in Vlat biopsies obtained from CEUS site. MA and YG had similar quadriceps muscle MRT-volume or PT and maximal oxygen uptake as well as a normal cardiovascular risk factors and intima-media-thickness. During isometric exercise MA compared to YG reached significantly lower levels in MFV (0.123±0.016 vs. 0.208±0.036 a.u.) and MBF (0.007±0.001 vs. 0.012±0.002 a.u.). In the VInt the (post-occlusive hyperemia) post-exercise peaks in MBV and MBF were significantly lower in MA vs. YG. Capillary density, capillary fiber contacts and femoral artery Doppler were similar between MA and YG. In the absence of significant age-related reductions in capillarisation, total leg blood flow or muscle mass, healthy middle-aged males reveal impaired skeletal muscle microcirculatory responses to isometric exercise. Whether this limits isometric muscle performance remains to be assessed.

  12. Application of computer-aided multi-scale modelling framework – Aerosol case study

    DEFF Research Database (Denmark)

    Heitzig, Martina; Sin, Gürkan; Glarborg, Peter

    2011-01-01

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy and water. This trend is set to continue due to the substantial benefits computer-aided...... methods provide. The key prerequisite of computer-aided product-process engineering is however the availability of models of different types, forms and application modes. The development of the models required for the systems under investigation tends to be a challenging and time-consuming task involving...... numerous steps, expert skills and different modelling tools. This motivates the development of a computer-aided modelling framework that supports the user during model development, documentation, analysis, identification, application and re-use with the goal to increase the efficiency of the modelling...

  13. Computer-aided Framework for Design of Pure, Mixed and Blended Products

    DEFF Research Database (Denmark)

    Cignitti, Stefano; Zhang, Lei; Gani, Rafiqul

    2015-01-01

    This paper presents a framework for computer-aided design of pure, mixed and blended chemical based products. The framework is a systematic approach to convert a Computer-aided Molecular, Mixture and Blend Design (CAMbD) formulation, based on needs and target properties, into a mixed integer non...

  14. Computer aided architectural design : futures 2001

    NARCIS (Netherlands)

    Vries, de B.; Leeuwen, van J.P.; Achten, H.H.

    2001-01-01

    CAAD Futures is a bi-annual conference that aims to promote the advancement of computer-aided architectural design in the service of those concerned with the quality of the built environment. The conferences are organized under the auspices of the CAAD Futures Foundation, which has its secretariat

  15. Application of computer aided tolerance analysis in product design

    International Nuclear Information System (INIS)

    Du Hua

    2009-01-01

    This paper introduces the shortage of the traditional tolerance design method and the strong point of the computer aided tolerancing (CAT) method,compares the shortage and the strong point among the three tolerance analysis methods, which are Worst Case Analysis, Statistical Analysis and Monte-Carlo Simulation Analysis, and offers the basic courses and correlative details for CAT. As the study objects, the reactor pressure vessel, the core barrel, the hold-down barrel and the support plate are used to upbuild the tolerance simulation model, based on their 3D design models. Then the tolerance simulation analysis has been conducted and the scheme of the tolerance distribution is optimized based on the analysis results. (authors)

  16. DICOM standard in computer-aided medical technologies

    International Nuclear Information System (INIS)

    Plotnikov, A.V.; Prilutskij, D.A.; Selishchev, S.V.

    1997-01-01

    The paper outlines one of the promising standards to transmit images in medicine, in radiology in particular. the essence of the standard DICOM is disclosed and promises of its introduction into computer-aided medical technologies

  17. Computer-Aided Drug Design in Epigenetics

    Science.gov (United States)

    Lu, Wenchao; Zhang, Rukang; Jiang, Hao; Zhang, Huimin; Luo, Cheng

    2018-03-01

    Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field.

  18. Computer-Aided Drug Design in Epigenetics

    Science.gov (United States)

    Lu, Wenchao; Zhang, Rukang; Jiang, Hao; Zhang, Huimin; Luo, Cheng

    2018-01-01

    Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation, and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field. PMID:29594101

  19. Computer-Aided Modelling Methods and Tools

    DEFF Research Database (Denmark)

    Cameron, Ian; Gani, Rafiqul

    2011-01-01

    The development of models for a range of applications requires methods and tools. In many cases a reference model is required that allows the generation of application specific models that are fit for purpose. There are a range of computer aided modelling tools available that help to define the m...

  20. Computer-aided translation tools

    DEFF Research Database (Denmark)

    Christensen, Tina Paulsen; Schjoldager, Anne

    2016-01-01

    in Denmark is rather high in general, but limited in the case of machine translation (MT) tools: While most TSPs use translation-memory (TM) software, often in combination with a terminology management system (TMS), only very few have implemented MT, which is criticised for its low quality output, especially......The paper reports on a questionnaire survey from 2013 of the uptake and use of computer-aided translation (CAT) tools by Danish translation service providers (TSPs) and discusses how these tools appear to have impacted on the Danish translation industry. According to our results, the uptake...

  1. [Development of computer aided forming techniques in manufacturing scaffolds for bone tissue engineering].

    Science.gov (United States)

    Wei, Xuelei; Dong, Fuhui

    2011-12-01

    To review recent advance in the research and application of computer aided forming techniques for constructing bone tissue engineering scaffolds. The literature concerning computer aided forming techniques for constructing bone tissue engineering scaffolds in recent years was reviewed extensively and summarized. Several studies over last decade have focused on computer aided forming techniques for bone scaffold construction using various scaffold materials, which is based on computer aided design (CAD) and bone scaffold rapid prototyping (RP). CAD include medical CAD, STL, and reverse design. Reverse design can fully simulate normal bone tissue and could be very useful for the CAD. RP techniques include fused deposition modeling, three dimensional printing, selected laser sintering, three dimensional bioplotting, and low-temperature deposition manufacturing. These techniques provide a new way to construct bone tissue engineering scaffolds with complex internal structures. With rapid development of molding and forming techniques, computer aided forming techniques are expected to provide ideal bone tissue engineering scaffolds.

  2. Computer-aided diagnosis of mammographic microcalcification clusters

    International Nuclear Information System (INIS)

    Kallergi, Maria

    2004-01-01

    Computer-aided diagnosis techniques in medical imaging are developed for the automated differentiation between benign and malignant lesions and go beyond computer-aided detection by providing cancer likelihood for a detected lesion given image and/or patient characteristics. The goal of this study was the development and evaluation of a computer-aided detection and diagnosis algorithm for mammographic calcification clusters. The emphasis was on the diagnostic component, although the algorithm included automated detection, segmentation, and classification steps based on wavelet filters and artificial neural networks. Classification features were selected primarily from descriptors of the morphology of the individual calcifications and the distribution of the cluster. Thirteen such descriptors were selected and, combined with patient's age, were given as inputs to the network. The features were ranked and evaluated for the classification of 100 high-resolution, digitized mammograms containing biopsy-proven, benign and malignant calcification clusters. The classification performance of the algorithm reached a 100% sensitivity for a specificity of 85% (receiver operating characteristic area index A z =0.98±0.01). Tests of the algorithm under various conditions showed that the selected features were robust morphological and distributional descriptors, relatively insensitive to segmentation and detection errors such as false positive signals. The algorithm could exceed the performance of a similar visual analysis system that was used as basis for development and, combined with a simple image standardization process, could be applied to images from different imaging systems and film digitizers with similar sensitivity and specificity rates

  3. A computer-aided software-tool for sustainable process synthesis-intensification

    DEFF Research Database (Denmark)

    Kumar Tula, Anjan; Babi, Deenesh K.; Bottlaender, Jack

    2017-01-01

    and determine within the design space, the more sustainable processes. In this paper, an integrated computer-aided software-tool that searches the design space for hybrid/intensified more sustainable process options is presented. Embedded within the software architecture are process synthesis...... operations as well as reported hybrid/intensified unit operations is large and can be difficult to manually navigate in order to determine the best process flowsheet for the production of a desired chemical product. Therefore, it is beneficial to utilize computer-aided methods and tools to enumerate, analyze...... constraints while also matching the design targets, they are therefore more sustainable than the base case. The application of the software-tool to the production of biodiesel is presented, highlighting the main features of the computer-aided, multi-stage, multi-scale methods that are able to determine more...

  4. Effect of radiation dose reduction and iterative reconstruction on computer-aided detection of pulmonary nodules : Intra-individual comparison

    NARCIS (Netherlands)

    Den Harder, Annemarie M.; Willemink, Martin J.; Van Hamersvelt, Robbert W.; Vonken, Evert-Jan P A; Milles, Julien; Schilham, Arnold M R; Lammers, Jan Willem; De Jong, Pim A.; Leiner, Tim; Budde, Ricardo P J

    2016-01-01

    Objective To evaluate the effect of radiation dose reduction and iterative reconstruction (IR) on the performance of computer-aided detection (CAD) for pulmonary nodules. Methods In this prospective study twenty-five patients were included who were scanned for pulmonary nodule follow-up. Image

  5. Computer-aided dental prostheses construction using reverse engineering.

    Science.gov (United States)

    Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O

    2014-01-01

    The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.

  6. Estimation of the failure risk of a maxillary premolar with different crack depths with endodontic treatment by computer-aided design/computer-aided manufacturing ceramic restorations.

    Science.gov (United States)

    Lin, Chun-Li; Chang, Yen-Hsiang; Hsieh, Shih-Kai; Chang, Wen-Jen

    2013-03-01

    This study evaluated the risk of failure for an endodontically treated premolar with different crack depths, which was shearing toward the pulp chamber and was restored by using 3 different computer-aided design/computer-aided manufacturing ceramic restoration configurations. Three 3-dimensional finite element models designed with computer-aided design/computer-aided manufacturing ceramic onlay, endocrown, and conventional crown restorations were constructed to perform simulations. The Weibull function was incorporated with finite element analysis to calculate the long-term failure probability relative to different load conditions. The results indicated that the stress values on the enamel, dentin, and luting cement for endocrown restorations exhibited the lowest values relative to the other 2 restoration methods. Weibull analysis revealed that the overall failure probabilities in a shallow cracked premolar were 27%, 2%, and 1% for the onlay, endocrown, and conventional crown restorations, respectively, in the normal occlusal condition. The corresponding values were 70%, 10%, and 2% for the depth cracked premolar. This numeric investigation suggests that the endocrown provides sufficient fracture resistance only in a shallow cracked premolar with endodontic treatment. The conventional crown treatment can immobilize the premolar for different cracked depths with lower failure risk. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Using virtual objects to aid underground storage tank teleoperation

    International Nuclear Information System (INIS)

    Anderson, R.J.; Davies, B.

    1994-01-01

    In this paper we describe an algorithm by which obstructions and surface features in an underground storage tank can be modeled and used to generate virtual barrier function for a real-time telerobotic system, which provides an aid to the operator for both real-time obstacle avoidance and for surface tracking. The algorithm requires that the slave's tool and every object in the waste storage tank be decomposed into convex polyhedral primitives, with the waste surface modeled by triangular prisms. Intrusion distance and extraction vectors are then derived at every time step by applying Gilbert's polyhedra distance algorithm, which has been adapted for the task. This information is then used to determine the compression and location of nonlinear virtual spring-dampers whose total force is summed and applied to the manipulator/teleoperator system. Experimental results using a PUMA 560 and a simulated waste surface validate the approach, showing that it is possible to compute the algorithm and generate smooth, realistic pseudo forces for the teleoperator system using standard VME bus hardware

  8. Computer-Aided Drug Design in Epigenetics

    Directory of Open Access Journals (Sweden)

    Wenchao Lu

    2018-03-01

    Full Text Available Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation, and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field.

  9. Computer-Aided Engineering Education at the K.U. Leuven.

    Science.gov (United States)

    Snoeys, R.; Gobin, R.

    1987-01-01

    Describes some recent initiatives and developments in the computer-aided design program in the engineering faculty of the Katholieke Universiteit Leuven (Belgium). Provides a survey of the engineering curriculum, the computer facilities, and the main software packages available. (TW)

  10. Framework for computer-aided systems design

    International Nuclear Information System (INIS)

    Esselman, W.H.

    1992-01-01

    Advanced computer technology, analytical methods, graphics capabilities, and expert systems contribute to significant changes in the design process. Continued progress is expected. Achieving the ultimate benefits of these computer-based design tools depends on successful research and development on a number of key issues. A fundamental understanding of the design process is a prerequisite to developing these computer-based tools. In this paper a hierarchical systems design approach is described, and methods by which computers can assist the designer are examined. A framework is presented for developing computer-based design tools for power plant design. These tools include expert experience bases, tutorials, aids in decision making, and tools to develop the requirements, constraints, and interactions among subsystems and components. Early consideration of the functional tasks is encouraged. Methods of acquiring an expert's experience base is a fundamental research problem. Computer-based guidance should be provided in a manner that supports the creativity, heuristic approaches, decision making, and meticulousness of a good designer

  11. Virtual environment and computer-aided technologies used for system prototyping and requirements development

    Science.gov (United States)

    Logan, Cory; Maida, James; Goldsby, Michael; Clark, Jim; Wu, Liew; Prenger, Henk

    1993-01-01

    The Space Station Freedom (SSF) Data Management System (DMS) consists of distributed hardware and software which monitor and control the many onboard systems. Virtual environment and off-the-shelf computer technologies can be used at critical points in project development to aid in objectives and requirements development. Geometric models (images) coupled with off-the-shelf hardware and software technologies were used in The Space Station Mockup and Trainer Facility (SSMTF) Crew Operational Assessment Project. Rapid prototyping is shown to be a valuable tool for operational procedure and system hardware and software requirements development. The project objectives, hardware and software technologies used, data gained, current activities, future development and training objectives shall be discussed. The importance of defining prototyping objectives and staying focused while maintaining schedules are discussed along with project pitfalls.

  12. Development of a computer-aided digital reactivity computer system for PWRs

    International Nuclear Information System (INIS)

    Chung, S.-K.; Sung, K.-Y.; Kim, D.; Cho, D.-Y.

    1993-01-01

    Reactor physics tests at initial startup and after reloading are performed to verify nuclear design and to ensure safety operation. Two kinds of reactivity computers, analog and digital, have been widely used in the pressurized water reactor (PWR) core physics test. The test data of both reactivity computers are displayed only on the strip chart recorder, and these data are managed by hand so that the accuracy of the test results depends on operator expertise and experiences. This paper describes the development of the computer-aided digital reactivity computer system (DRCS), which is enhanced by system management software and an improved system for the application of the PWR core physics test

  13. SOFTWARE FOR COMPUTER-AIDED DESIGN OF CROSS-WEDGE ROLLING

    OpenAIRE

    A. A. Abramov; S. V. Medvedev

    2013-01-01

    The issues of computer technology creation of 3D-design and engineering analysis of metal forming processes using cross wedge rolling methods (CWR) are considered. The developed software for computer-aided design and simulation of cross-wedge rolling is described.

  14. Computer-Aided Methodology for Syndromic Strabismus Diagnosis.

    Science.gov (United States)

    Sousa de Almeida, João Dallyson; Silva, Aristófanes Corrêa; Teixeira, Jorge Antonio Meireles; Paiva, Anselmo Cardoso; Gattass, Marcelo

    2015-08-01

    Strabismus is a pathology that affects approximately 4 % of the population, causing aesthetic problems reversible at any age and irreversible sensory alterations that modify the vision mechanism. The Hirschberg test is one type of examination for detecting this pathology. Computer-aided detection/diagnosis is being used with relative success to aid health professionals. Nevertheless, the routine use of high-tech devices for aiding ophthalmological diagnosis and therapy is not a reality within the subspecialty of strabismus. Thus, this work presents a methodology to aid in diagnosis of syndromic strabismus through digital imaging. Two hundred images belonging to 40 patients previously diagnosed by an specialist were tested. The method was demonstrated to be 88 % accurate in esotropias identification (ET), 100 % for exotropias (XT), 80.33 % for hypertropias (HT), and 83.33 % for hypotropias (HoT). The overall average error was 5.6Δ and 3.83Δ for horizontal and vertical deviations, respectively, against the measures presented by the specialist.

  15. Computer aided monitoring of breast abnormalities in X-ray mammograms

    OpenAIRE

    Selvan, Arul; Saatchi, Reza; Ferris, Christine

    2011-01-01

    X­ray mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, but the interpretation of mammograms is a difficult and \\ud error­prone task. Computer­aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer­aided diagnosis (CADx) systems assist the radiologist in the classification of mammographic lesions as benign or malignant[1].\\ud This p...

  16. Unit cell-based computer-aided manufacturing system for tissue engineering

    International Nuclear Information System (INIS)

    Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo

    2012-01-01

    Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering. (paper)

  17. Unit cell-based computer-aided manufacturing system for tissue engineering.

    Science.gov (United States)

    Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo

    2012-03-01

    Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering.

  18. Computer-Aided Design in Further Education.

    Science.gov (United States)

    Ingham, Peter, Ed.

    This publication updates the 1982 occasional paper that was intended to foster staff awareness and assist colleges in Great Britain considering the use of computer-aided design (CAD) material in engineering courses. The paper begins by defining CAD and its place in the Integrated Business System with a brief discussion of the effect of CAD on the…

  19. NALDA (Naval Aviation Logistics Data Analysis) CAI (computer aided instruction)

    Energy Technology Data Exchange (ETDEWEB)

    Handler, B.H. (Oak Ridge K-25 Site, TN (USA)); France, P.A.; Frey, S.C.; Gaubas, N.F.; Hyland, K.J.; Lindsey, A.M.; Manley, D.O. (Oak Ridge Associated Universities, Inc., TN (USA)); Hunnum, W.H. (North Carolina Univ., Chapel Hill, NC (USA)); Smith, D.L. (Memphis State Univ., TN (USA))

    1990-07-01

    Data Systems Engineering Organization (DSEO) personnel developed a prototype computer aided instruction CAI system for the Naval Aviation Logistics Data Analysis (NALDA) system. The objective of this project was to provide a CAI prototype that could be used as an enhancement to existing NALDA training. The CAI prototype project was performed in phases. The task undertaken in Phase I was to analyze the problem and the alternative solutions and to develop a set of recommendations on how best to proceed. The findings from Phase I are documented in Recommended CAI Approach for the NALDA System (Duncan et al., 1987). In Phase II, a structured design and specifications were developed, and a prototype CAI system was created. A report, NALDA CAI Prototype: Phase II Final Report, was written to record the findings and results of Phase II. NALDA CAI: Recommendations for an Advanced Instructional Model, is comprised of related papers encompassing research on computer aided instruction CAI, newly developing training technologies, instructional systems development, and an Advanced Instructional Model. These topics were selected because of their relevancy to the CAI needs of NALDA. These papers provide general background information on various aspects of CAI and give a broad overview of new technologies and their impact on the future design and development of training programs. The paper within have been index separately elsewhere.

  20. Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing.

    Science.gov (United States)

    Oh, Ji-Hyeon

    2018-12-01

    With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

  1. Enabling Lean Design Through Computer Aided Synthesis: The Injection Moulding Cooling Case

    NARCIS (Netherlands)

    Jauregui Becker, Juan Manuel; Wits, Wessel Willems

    2015-01-01

    This paper explores the application of Computer Aided Synthesis (CAS) to support the implementation of Set-Based Concurrent Engineering (SBCE) and Just In Time Decision Making (JIT-DM), which are considered as two of the cornerstones of the Lean Design method. Computer Aided Synthesis refers to a

  2. Computer Aided Continuous Time Stochastic Process Modelling

    DEFF Research Database (Denmark)

    Kristensen, N.R.; Madsen, Henrik; Jørgensen, Sten Bay

    2001-01-01

    A grey-box approach to process modelling that combines deterministic and stochastic modelling is advocated for identification of models for model-based control of batch and semi-batch processes. A computer-aided tool designed for supporting decision-making within the corresponding modelling cycle...

  3. Age-related differences in skeletal muscle microvascular response to exercise as detected by contrast-enhanced ultrasound (CEUS.

    Directory of Open Access Journals (Sweden)

    Wulf Hildebrandt

    Full Text Available Aging involves reductions in exercise total limb blood flow and exercise capacity. We hypothesized that this may involve early age-related impairments of skeletal muscle microvascular responsiveness as previously reported for insulin but not for exercise stimuli in humans.Using an isometric exercise model, we studied the effect of age on contrast-enhanced ultrasound (CEUS parameters, i.e. microvascular blood volume (MBV, flow velocity (MFV and blood flow (MBF calculated from replenishment of Sonovue contrast-agent microbubbles after their destruction. CEUS was applied to the vastus lateralis (VLat and intermedius (VInt muscle in 15 middle-aged (MA, 43.6±1.5 years and 11 young (YG, 24.1±0.6 years healthy males before, during, and after 2 min of isometric knee extension at 15% of peak torque (PT. In addition, total leg blood flow as recorded by femoral artery Doppler-flow. Moreover, fiber-type-specific and overall capillarisation as well as fiber composition were additionally assessed in Vlat biopsies obtained from CEUS site. MA and YG had similar quadriceps muscle MRT-volume or PT and maximal oxygen uptake as well as a normal cardiovascular risk factors and intima-media-thickness.During isometric exercise MA compared to YG reached significantly lower levels in MFV (0.123±0.016 vs. 0.208±0.036 a.u. and MBF (0.007±0.001 vs. 0.012±0.002 a.u.. In the VInt the (post-occlusive hyperemia post-exercise peaks in MBV and MBF were significantly lower in MA vs. YG. Capillary density, capillary fiber contacts and femoral artery Doppler were similar between MA and YG.In the absence of significant age-related reductions in capillarisation, total leg blood flow or muscle mass, healthy middle-aged males reveal impaired skeletal muscle microcirculatory responses to isometric exercise. Whether this limits isometric muscle performance remains to be assessed.

  4. [Computer-aided prescribing: from utopia to reality].

    Science.gov (United States)

    Suárez-Varela Ubeda, J; Beltrán Calvo, C; Molina López, T; Navarro Marín, P

    2005-05-31

    To determine whether the introduction of computer-aided prescribing helped reduce the administrative burden at primary care centers. Descriptive, cross-sectional design. Torreblanca Health Center in the province of Seville, southern Spain. From 29 October 2003 to the present a pilot project involving nine pharmacies in the basic health zone served by this health center has been running to evaluate computer-aided prescribing (the Receta XXI project) with real patients. All patients on the center's list of patients who came to the center for an administrative consultation to renew prescriptions for medications or supplies for long-term treatment. Total number of administrative visits per patient for patients who came to the center to renew prescriptions for long-term treatment, as recorded by the Diraya system (Historia Clinica Digital del Ciudadano, or Citizen's Digital Medical Record) during the period from February to July 2004. Total number of the same type of administrative visits recorded by the previous system (TASS) during the period from February to July 2003. The mean number of administrative visits per month during the period from February to July 2003 was 160, compared to a mean number of 64 visits during the period from February to July 2004. The reduction in the number of visits for prescription renewal was 60%. Introducing a system for computer-aided prescribing significantly reduced the number of administrative visits for prescription renewal for long-term treatment. This could help reduce the administrative burden considerably in primary care if the system were used in all centers.

  5. Teaching Computer-Aided Design of Fluid Flow and Heat Transfer Engineering Equipment.

    Science.gov (United States)

    Gosman, A. D.; And Others

    1979-01-01

    Describes a teaching program for fluid mechanics and heat transfer which contains both computer aided learning (CAL) and computer aided design (CAD) components and argues that the understanding of the physical and numerical modeling taught in the CAL course is essential to the proper implementation of CAD. (Author/CMV)

  6. Computer-Presented Organizational/Memory Aids as Instruction for Solving Pico-Fomi Problems.

    Science.gov (United States)

    Steinberg, Esther R.; And Others

    1985-01-01

    Describes investigation of effectiveness of computer-presented organizational/memory aids (matrix and verbal charts controlled by computer or learner) as instructional technique for solving Pico-Fomi problems, and the acquisition of deductive inference rules when such aids are present. Results indicate chart use control should be adapted to…

  7. Analysis of Computer-Aided and Artificial Intelligence Technologies and Solutions in Service Industries in Russia

    OpenAIRE

    Rezanov, Vladislav

    2013-01-01

    The primary objective of this research study was to investigate the relationship between Computer-Aided and Artificial Intelligence Technologies and customer satisfaction in the context of businesses in Russia. The research focuses on methods of Artificial Intelligence technology application in business and its effect on customer satisfaction. The researcher introduces Artificial Intelligence and studies the forecasting approaches in relation to business operations. The rese...

  8. Creation of 'Ukrytie' objects computer model

    International Nuclear Information System (INIS)

    Mazur, A.B.; Kotlyarov, V.T.; Ermolenko, A.I.; Podbereznyj, S.S.; Postil, S.D.; Shaptala, D.V.

    1999-01-01

    A partial computer model of the 'Ukrytie' object was created with the use of geoinformation technologies. The computer model makes it possible to carry out information support of the works related to the 'Ukrytie' object stabilization and its conversion into ecologically safe system for analyzing, forecasting and controlling the processes occurring in the 'Ukrytie' object. Elements and structures of the 'Ukryttia' object were designed and input into the model

  9. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration

    Directory of Open Access Journals (Sweden)

    Juntavee N

    2018-02-01

    Full Text Available Niwut Juntavee,1 Issarawas Sirisathit2 1Department of Prosthodontics, 2Division of Biomaterials and Prosthodontics Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand Objective: This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM systems (Trios-3 and CS3500 in comparison to conventional cast metal restoration. Materials and methods: A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel–chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA and Tukey’s honest significant difference (HSD multiple comparisons were used to determine statistically significant difference at 95% confidence interval. Results: The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system (p<0.05. Tukey’s HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration (p<0.05. Conclusion: Full

  10. Computer aided design of solonoid magnets

    Energy Technology Data Exchange (ETDEWEB)

    DeOlivares, J.M.

    1978-06-01

    Computer programs utilizing Legendre functions and elliptic integral functions have been written to aid in the design of solenoid magnets. The field inside an axisymmetric magnet can be expanded in a converging power series of Legendre functions. The Legendre function approach is very useful for designing solenoid magnets with a high degree of field uniformity. This approach has been programed on the LBL CDC 7600 computer so that one can design an axisymmetric magnet which meets any desired field structure. Two examples of computer designed solenoids are presented. A computer program utilizing elliptic integral functions was also written for the LBL CDC 7600 computer. This method was used in a computer program to verify the results obtained from the Legendre approach and for field calculations within the conductor. The elliptic integral field calculations within the conductor showed that thin solenoids produce field peaking at the ends of the magnet. Computer data is generated for various magnet geometries and compared with theoretical predictions. Computer results and theoretical prediction both show that field peaking is reduced for longer coils, increased for thinner coils and field peaking is a logarithmic function of length, thickness and radius.

  11. Computer aids for plant operators

    International Nuclear Information System (INIS)

    Joly, J.P.

    1992-01-01

    For some time, particularly since the TMI accident, nuclear power plant operators have been aware of the difficulties involved in diagnosing accidents and returning plants to their stable, safe operating mode. There are various possible solutions to these problems: improve control organization during accident situations, rewrite control procedures, integrate safety engineers in shifts, improve control rooms, and implement additional computer aids. The purpose of this presentation is to describe the efforts undertaken by EDF over the last few years in this field

  12. Computer-Aided Characterization and Diagnosis of Diffuse Liver Diseases Based on Ultrasound Imaging: A Review.

    Science.gov (United States)

    Bharti, Puja; Mittal, Deepti; Ananthasivan, Rupa

    2016-04-19

    Diffuse liver diseases, such as hepatitis, fatty liver, and cirrhosis, are becoming a leading cause of fatality and disability all over the world. Early detection and diagnosis of these diseases is extremely important to save lives and improve effectiveness of treatment. Ultrasound imaging, a noninvasive diagnostic technique, is the most commonly used modality for examining liver abnormalities. However, the accuracy of ultrasound-based diagnosis depends highly on expertise of radiologists. Computer-aided diagnosis systems based on ultrasound imaging assist in fast diagnosis, provide a reliable "second opinion" for experts, and act as an effective tool to measure response of treatment on patients undergoing clinical trials. In this review, we first describe appearance of liver abnormalities in ultrasound images and state the practical issues encountered in characterization of diffuse liver diseases that can be addressed by software algorithms. We then discuss computer-aided diagnosis in general with features and classifiers relevant to diffuse liver diseases. In later sections of this paper, we review the published studies and describe the key findings of those studies. A concise tabular summary comparing image database, features extraction, feature selection, and classification algorithms presented in the published studies is also exhibited. Finally, we conclude with a summary of key findings and directions for further improvements in the areas of accuracy and objectiveness of computer-aided diagnosis. © The Author(s) 2016.

  13. A novel technique for presurgical nasoalveolar molding using computer-aided reverse engineering and rapid prototyping.

    Science.gov (United States)

    Yu, Quan; Gong, Xin; Wang, Guo-Min; Yu, Zhe-Yuan; Qian, Yu-Fen; Shen, Gang

    2011-01-01

    To establish a new method of presurgical nasoalveolar molding (NAM) using computer-aided reverse engineering and rapid prototyping technique in infants with unilateral cleft lip and palate (UCLP). Five infants (2 males and 3 females with mean age of 1.2 w) with complete UCLP were recruited. All patients were subjected to NAM before the cleft lip repair. The upper denture casts were recorded using a three-dimensional laser scanner within 2 weeks after birth in UCLP infants. A digital model was constructed and analyzed to simulate the NAM procedure with reverse engineering software. The digital geometrical data were exported to print the solid model with rapid prototyping system. The whole set of appliances was fabricated based on these solid models. Laser scanning and digital model construction simplified the NAM procedure and estimated the treatment objective. The appliances were fabricated based on the rapid prototyping technique, and for each patient, the complete set of appliances could be obtained at one time. By the end of presurgical NAM treatment, the cleft was narrowed, and the malformation of nasoalveolar segments was aligned normally. We have developed a novel technique of presurgical NAM based on a computer-aided design. The accurate digital denture model of UCLP infants could be obtained with laser scanning. The treatment design and appliance fabrication could be simplified with a computer-aided reverse engineering and rapid prototyping technique.

  14. Software Engineering Techniques for Computer-Aided Learning.

    Science.gov (United States)

    Ibrahim, Bertrand

    1989-01-01

    Describes the process for developing tutorials for computer-aided learning (CAL) using a programing language rather than an authoring system. The workstation used is described, the use of graphics is discussed, the role of a local area network (LAN) is explained, and future plans are discussed. (five references) (LRW)

  15. Computer Navigation-aided Resection of Sacral Chordomas

    Directory of Open Access Journals (Sweden)

    Yong-Kun Yang

    2016-01-01

    Full Text Available Background: Resection of sacral chordomas is challenging. The anatomy is complex, and there are often no bony landmarks to guide the resection. Achieving adequate surgical margins is, therefore, difficult, and the recurrence rate is high. Use of computer navigation may allow optimal preoperative planning and improve precision in tumor resection. The purpose of this study was to evaluate the safety and feasibility of computer navigation-aided resection of sacral chordomas. Methods: Between 2007 and 2013, a total of 26 patients with sacral chordoma underwent computer navigation-aided surgery were included and followed for a minimum of 18 months. There were 21 primary cases and 5 recurrent cases, with a mean age of 55.8 years old (range: 35-84 years old. Tumors were located above the level of the S3 neural foramen in 23 patients and below the level of the S3 neural foramen in 3 patients. Three-dimensional images were reconstructed with a computed tomography-based navigation system combined with the magnetic resonance images using the navigation software. Tumors were resected via a posterior approach assisted by the computer navigation. Mean follow-up was 38.6 months (range: 18-84 months. Results: Mean operative time was 307 min. Mean intraoperative blood loss was 3065 ml. For computer navigation, the mean registration deviation during surgery was 1.7 mm. There were 18 wide resections, 4 marginal resections, and 4 intralesional resections. All patients were alive at the final follow-up, with 2 (7.7% exhibiting tumor recurrence. The other 24 patients were tumor-free. The mean Musculoskeletal Tumor Society Score was 27.3 (range: 19-30. Conclusions: Computer-assisted navigation can be safely applied to the resection of the sacral chordomas, allowing execution of preoperative plans, and achieving good oncological outcomes. Nevertheless, this needs to be accomplished by surgeons with adequate experience and skill.

  16. Method of Computer-aided Instruction in Situation Control Systems

    Directory of Open Access Journals (Sweden)

    Anatoliy O. Kargin

    2013-01-01

    Full Text Available The article considers the problem of computer-aided instruction in context-chain motivated situation control system of the complex technical system behavior. The conceptual and formal models of situation control with practical instruction are considered. Acquisition of new behavior knowledge is presented as structural changes in system memory in the form of situational agent set. Model and method of computer-aided instruction represent formalization, based on the nondistinct theories by physiologists and cognitive psychologists.The formal instruction model describes situation and reaction formation and dependence on different parameters, effecting education, such as the reinforcement value, time between the stimulus, action and the reinforcement. The change of the contextual link between situational elements when using is formalized.The examples and results of computer instruction experiments of the robot device “LEGO MINDSTORMS NXT”, equipped with ultrasonic distance, touch, light sensors.

  17. Computer Aided Design System for Developing Musical Fountain Programs

    Institute of Scientific and Technical Information of China (English)

    刘丹; 张乃尧; 朱汉城

    2003-01-01

    A computer aided design system for developing musical fountain programs was developed with multiple functions such as intelligent design, 3-D animation, manual modification and synchronized motion to make the development process more efficient. The system first analyzed the music form and sentiment using many basic features of the music to select a basic fountain program. Then, this program is simulated with 3-D animation and modified manually to achieve the desired results. Finally, the program is transformed to a computer control program to control the musical fountain in time with the music. A prototype system for the musical fountain was also developed. It was tested with many styles of music and users were quite satisfied with its performance. By integrating various functions, the proposed computer aided design system for developing musical fountain programs greatly simplified the design of the musical fountain programs.

  18. A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation.

    Science.gov (United States)

    Chen, Xiaojun; Xu, Lu; Sun, Yi; Politis, Constantinus

    2016-11-01

    Currently, oral and maxillofacial surgery (OMFS) still poses a significant challenge for surgeons due to the anatomic complexity and limited field of view of the oral cavity. With the great development of computer technologies, he computer-aided surgery has been widely used for minimizing the risks and improving the precision of surgery. Areas covered: The major goal of this paper is to provide a comprehensive reference source of current and future development of computer-aided OMFS including surgical planning, simulation and navigation for relevant researchers. Expert commentary: Compared with the traditional OMFS, computer-aided OMFS overcomes the disadvantage that the treatment on the region of anatomically complex maxillofacial depends almost exclusively on the experience of the surgeon.

  19. A Design of Computer Aided Instructions (CAI) for Undirected Graphs in the Discrete Math Tutorial (DMT). Part 1.

    Science.gov (United States)

    1990-06-01

    The objective of this thesis research is to create a tutorial for teaching aspects of undirected graphs in discrete math . It is one of the submodules...of the Discrete Math Tutorial (DMT), which is a Computer Aided Instructional (CAI) tool for teaching discrete math to the Naval Academy and the

  20. A Design of Computer Aided Instructions (CAI) for Undirected Graphs in the Discrete Math Tutorial (DMT). Part 2

    Science.gov (United States)

    1990-06-01

    The objective of this thesis research is to create a tutorial for teaching aspects of undirected graphs in discrete math . It is one of the submodules...of the Discrete Math Tutorial (DMT), which is a Computer Aided Instructional (CAI) tool for teaching discrete math to the Naval Academy and the

  1. Intra-biliary contrast-enhanced ultrasound for evaluating biliary obstruction during percutaneous transhepatic biliary drainage: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Er-jiao [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China); Zheng, Rong-qin, E-mail: zhengrq@mail.sysu.edu.cn [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China); Su, Zhong-zhen; Li, Kai; Ren, Jie; Guo, Huan-yi [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China)

    2012-12-15

    Objectives: The aimed of this study was to investigate the value of intra-biliary contrast-enhanced ultrasound (IB-CEUS) for evaluating biliary obstruction during percutaneous transhepatic biliary drainage (PTBD). Materials and methods: 80 patients with obstructive jaundice who underwent IB-CEUS during PTBD were enrolled. The diluted ultrasound contrast agent was injected via the drainage catheter to perform IB-CEUS. Both conventional ultrasound and IB-CEUS were used to detect the tips of the drainage catheters and to compare the detection rates of the tips. The obstructive level and degree of biliary tract were evaluated by IB-CEUS. Fluoroscopic cholangiography (FC) and computer tomography cholangiography (CTC) were taken as standard reference for comparison. Results: Conventional ultrasound displayed only 43 tips (43/80, 53.8%) of the drainage catheters within the bile ducts while IB-CEUS identified all 80 tips (80/80, 100%) of the drainage catheters including 4 of them out of the bile duct (P < 0.001). IB-CEUS made correct diagnosis in 44 patients with intrahepatic and 36 patients with extrahepatic biliary obstructions. IB-CEUS accurately demonstrated complete obstruction in 56 patients and incomplete obstruction in 21 patients. There were 3 patients with incomplete obstruction misdiagnosed to be complete obstruction by IB-CEUS. The diagnostic accuracy of biliary obstruction degree was 96.3% (77/80). Conclusion: IB-CEUS could improve the visualization of the drainage catheters and evaluate the biliary obstructive level and degree during PTBD. IB-CEUS may be the potential substitute to FC in the PTBD procedure.

  2. Prosthetic rehabilitation with an implant-supported fixed prosthesis using computer-aided design and computer-aided manufacturing dental technology for a patient with a mandibulectomy: A clinical report.

    Science.gov (United States)

    Yoon, Hyung-In; Han, Jung-Suk

    2016-02-01

    The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Computer-aided classification of breast masses using contrast-enhanced digital mammograms

    Science.gov (United States)

    Danala, Gopichandh; Aghaei, Faranak; Heidari, Morteza; Wu, Teresa; Patel, Bhavika; Zheng, Bin

    2018-02-01

    By taking advantages of both mammography and breast MRI, contrast-enhanced digital mammography (CEDM) has emerged as a new promising imaging modality to improve efficacy of breast cancer screening and diagnosis. The primary objective of study is to develop and evaluate a new computer-aided detection and diagnosis (CAD) scheme of CEDM images to classify between malignant and benign breast masses. A CEDM dataset consisting of 111 patients (33 benign and 78 malignant) was retrospectively assembled. Each case includes two types of images namely, low-energy (LE) and dual-energy subtracted (DES) images. First, CAD scheme applied a hybrid segmentation method to automatically segment masses depicting on LE and DES images separately. Optimal segmentation results from DES images were also mapped to LE images and vice versa. Next, a set of 109 quantitative image features related to mass shape and density heterogeneity was initially computed. Last, four multilayer perceptron-based machine learning classifiers integrated with correlationbased feature subset evaluator and leave-one-case-out cross-validation method was built to classify mass regions depicting on LE and DES images, respectively. Initially, when CAD scheme was applied to original segmentation of DES and LE images, the areas under ROC curves were 0.7585+/-0.0526 and 0.7534+/-0.0470, respectively. After optimal segmentation mapping from DES to LE images, AUC value of CAD scheme significantly increased to 0.8477+/-0.0376 (pbreast tissue on lesions, segmentation accuracy was significantly improved as compared to regular mammograms, the study demonstrated that computer-aided classification of breast masses using CEDM images yielded higher performance.

  4. Computer aided system engineering for space construction

    Science.gov (United States)

    Racheli, Ugo

    1989-01-01

    This viewgraph presentation covers the following topics. Construction activities envisioned for the assembly of large platforms in space (as well as interplanetary spacecraft and bases on extraterrestrial surfaces) require computational tools that exceed the capability of conventional construction management programs. The Center for Space Construction is investigating the requirements for new computational tools and, at the same time, suggesting the expansion of graduate and undergraduate curricula to include proficiency in Computer Aided Engineering (CAE) though design courses and individual or team projects in advanced space systems design. In the center's research, special emphasis is placed on problems of constructability and of the interruptability of planned activity sequences to be carried out by crews operating under hostile environmental conditions. The departure point for the planned work is the acquisition of the MCAE I-DEAS software, developed by the Structural Dynamics Research Corporation (SDRC), and its expansion to the level of capability denoted by the acronym IDEAS**2 currently used for configuration maintenance on Space Station Freedom. In addition to improving proficiency in the use of I-DEAS and IDEAS**2, it is contemplated that new software modules will be developed to expand the architecture of IDEAS**2. Such modules will deal with those analyses that require the integration of a space platform's configuration with a breakdown of planned construction activities and with a failure modes analysis to support computer aided system engineering (CASE) applied to space construction.

  5. Use of computer-aided x-ray diagnosis in oncology. [60 refs

    Energy Technology Data Exchange (ETDEWEB)

    Rotte, K H [Forschungsinstitut fuer Lungenkrankheiten und Tuberkulose, Berlin-Buch (German Democratic Republic)

    1979-01-01

    The introduction of computer-aided diagnostic reveals new perspectives for diagnostic decisions. The results of the hitherto used mathematical diagnostic models are represented. The Bayes's theorem as the most used model exhibited very different, in part unsatisfactory results. More convenient seem to be multivariate models, like discriminant analysis. Hitherto the computer-aided diagnosis was used in a relative small number of problems concerning differential diagnosis. It is necessary to compare the efficiency of the different mathematical-statistical methods.

  6. Three-Dimensional Computer-Aided Detection of Microcalcification Clusters in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Ji-wook Jeong

    2016-01-01

    Full Text Available We propose computer-aided detection (CADe algorithm for microcalcification (MC clusters in reconstructed digital breast tomosynthesis (DBT images. The algorithm consists of prescreening, MC detection, clustering, and false-positive (FP reduction steps. The DBT images containing the MC-like objects were enhanced by a multiscale Hessian-based three-dimensional (3D objectness response function and a connected-component segmentation method was applied to extract the cluster seed objects as potential clustering centers of MCs. Secondly, a signal-to-noise ratio (SNR enhanced image was also generated to detect the individual MC candidates and prescreen the MC-like objects. Each cluster seed candidate was prescreened by counting neighboring individual MC candidates nearby the cluster seed object according to several microcalcification clustering criteria. As a second step, we introduced bounding boxes for the accepted seed candidate, clustered all the overlapping cubes, and examined. After the FP reduction step, the average number of FPs per case was estimated to be 2.47 per DBT volume with a sensitivity of 83.3%.

  7. Single photon emission computed tomography in AIDS dementia complex

    International Nuclear Information System (INIS)

    Pohl, P.; Vogl, G.; Fill, H.; Roessler, H.Z.; Zangerle, R.; Gerstenbrand, F.

    1988-01-01

    Single photon emission computed tomography (SPECT) studies were performed in AIDS dementia complex using IMP in 12 patients (and HM-PAO in four of these same patients). In all patients, SPECT revealed either multiple or focal uptake defects, the latter corresponding with focal signs or symptoms in all but one case. Computerized tomography showed a diffuse cerebral atrophy in eight of 12 patients, magnetic resonance imaging exhibited changes like atrophy and/or leukoencephalopathy in two of five cases. Our data indicate that both disturbance of cerebral amine metabolism and alteration of local perfusion share in the pathogenesis of AIDS dementia complex. SPECT is an important aid in the diagnosis of AIDS dementia complex and contributes to the understanding of the pathophysiological mechanisms of this disorder

  8. Speech-enabled Computer-aided Translation

    DEFF Research Database (Denmark)

    Mesa-Lao, Bartolomé

    2014-01-01

    The present study has surveyed post-editor trainees’ views and attitudes before and after the introduction of speech technology as a front end to a computer-aided translation workbench. The aim of the survey was (i) to identify attitudes and perceptions among post-editor trainees before performing...... a post-editing task using automatic speech recognition (ASR); and (ii) to assess the degree to which post-editors’ attitudes and expectations to the use of speech technology changed after actually using it. The survey was based on two questionnaires: the first one administered before the participants...

  9. Computer Aided Detection of Breast Masses in Digital Tomosynthesis

    National Research Council Canada - National Science Library

    Singh, Swatee; Lo, Joseph

    2008-01-01

    The purpose of this study was to investigate feasibility of computer-aided detection of masses and calcification clusters in breast tomosynthesis images and obtain reliable estimates of sensitivity...

  10. A non-linear programming approach to the computer-aided design of regulators using a linear-quadratic formulation

    Science.gov (United States)

    Fleming, P.

    1985-01-01

    A design technique is proposed for linear regulators in which a feedback controller of fixed structure is chosen to minimize an integral quadratic objective function subject to the satisfaction of integral quadratic constraint functions. Application of a non-linear programming algorithm to this mathematically tractable formulation results in an efficient and useful computer-aided design tool. Particular attention is paid to computational efficiency and various recommendations are made. Two design examples illustrate the flexibility of the approach and highlight the special insight afforded to the designer.

  11. The University of Michigan's Computer-Aided Engineering Network.

    Science.gov (United States)

    Atkins, D. E.; Olsen, Leslie A.

    1986-01-01

    Presents an overview of the Computer-Aided Engineering Network (CAEN) of the University of Michigan. Describes its arrangement of workstations, communication networks, and servers. Outlines the factors considered in hardware and software decision making. Reviews the program's impact on students. (ML)

  12. Computer-Aided Prototyping Systems (CAPS) within the software acquisition process: a case study

    OpenAIRE

    Ellis, Mary Kay

    1993-01-01

    Approved for public release; distribution is unlimited This thesis provides a case study which examines the benefits derived from the practice of computer-aided prototyping within the software acquisition process. An experimental prototyping systems currently in research is the Computer Aided Prototyping System (CAPS) managed under the Computer Science department of the Naval Postgraduate School, Monterey, California. This thesis determines the qualitative value which may be realized by ...

  13. Custom-Made Computer-Aided-Design/Computer-Aided-Manufacturing Biphasic Calcium-Phosphate Scaffold for Augmentation of an Atrophic Mandibular Anterior Ridge

    Directory of Open Access Journals (Sweden)

    Francesco Guido Mangano

    2015-01-01

    Full Text Available This report documents the clinical, radiographic, and histologic outcome of a custom-made computer-aided-design/computer-aided-manufactured (CAD/CAM scaffold used for the alveolar ridge augmentation of a severely atrophic anterior mandible. Computed tomographic (CT images of an atrophic anterior mandible were acquired and modified into a 3-dimensional (3D reconstruction model; this was transferred to a CAD program, where a custom-made scaffold was designed. CAM software generated a set of tool-paths for the manufacture of the scaffold on a computer-numerical-control milling machine into the exact shape of the 3D design. A custom-made scaffold was milled from a synthetic micromacroporous biphasic calcium phosphate (BCP block. The scaffold closely matched the shape of the defect: this helped to reduce the time for the surgery and contributed to good healing. One year later, newly formed and well-integrated bone was clinically available, and two implants (AnyRidge, MegaGen, Gyeongbuk, South Korea were placed. The histologic samples retrieved from the implant sites revealed compact mature bone undergoing remodelling, marrow spaces, and newly formed trabecular bone surrounded by residual BCP particles. This study demonstrates that custom-made scaffolds can be fabricated by combining CT scans and CAD/CAM techniques. Further studies on a larger sample of patients are needed to confirm these results.

  14. Comparison of 3D computer-aided with manual cerebral aneurysm measurements in different imaging modalities

    International Nuclear Information System (INIS)

    Groth, M.; Buhk, J.H.; Schoenfeld, M.; Goebell, E.; Fiehler, J.; Forkert, N.D.

    2013-01-01

    To compare intra- and inter-observer reliability of aneurysm measurements obtained by a 3D computer-aided technique with standard manual aneurysm measurements in different imaging modalities. A total of 21 patients with 29 cerebral aneurysms were studied. All patients underwent digital subtraction angiography (DSA), contrast-enhanced (CE-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA). Aneurysm neck and depth diameters were manually measured by two observers in each modality. Additionally, semi-automatic computer-aided diameter measurements were performed using 3D vessel surface models derived from CE- (CE-com) and TOF-MRA (TOF-com) datasets. Bland-Altman analysis (BA) and intra-class correlation coefficient (ICC) were used to evaluate intra- and inter-observer agreement. BA revealed the narrowest relative limits of intra- and inter-observer agreement for aneurysm neck and depth diameters obtained by TOF-com (ranging between ±5.3 % and ±28.3 %) and CE-com (ranging between ±23.3 % and ±38.1 %). Direct measurements in DSA, TOF-MRA and CE-MRA showed considerably wider limits of agreement. The highest ICCs were observed for TOF-com and CE-com (ICC values, 0.92 or higher for intra- as well as inter-observer reliability). Computer-aided aneurysm measurement in 3D offers improved intra- and inter-observer reliability and a reproducible parameter extraction, which may be used in clinical routine and as objective surrogate end-points in clinical trials. (orig.)

  15. Evaluation of the efficiency of computer-aided spectra search systems based on information theory

    International Nuclear Information System (INIS)

    Schaarschmidt, K.

    1979-01-01

    Application of information theory allows objective evaluation of the efficiency of computer-aided spectra search systems. For this purpose, a significant number of search processes must be analyzed. The amount of information gained by computer application is considered as the difference between the entropy of the data bank and a conditional entropy depending on the proportion of unsuccessful search processes and ballast. The influence of the following factors can be estimated: volume, structure, and quality of the spectra collection stored, efficiency of the encoding instruction and the comparing algorithm, and subjective errors involved in the encoding of spectra. The relations derived are applied to two published storage and retrieval systems for infared spectra. (Auth.)

  16. Teaching advance care planning to medical students with a computer-based decision aid.

    Science.gov (United States)

    Green, Michael J; Levi, Benjamin H

    2011-03-01

    Discussing end-of-life decisions with cancer patients is a crucial skill for physicians. This article reports findings from a pilot study evaluating the effectiveness of a computer-based decision aid for teaching medical students about advance care planning. Second-year medical students at a single medical school were randomized to use a standard advance directive or a computer-based decision aid to help patients with advance care planning. Students' knowledge, skills, and satisfaction were measured by self-report; their performance was rated by patients. 121/133 (91%) of students participated. The Decision-Aid Group (n = 60) outperformed the Standard Group (n = 61) in terms of students' knowledge (p satisfaction with their learning experience (p student performance. Use of a computer-based decision aid may be an effective way to teach medical students how to discuss advance care planning with cancer patients.

  17. Development of the computer-aided process planning (CAPP system for polymer injection molds manufacturing

    Directory of Open Access Journals (Sweden)

    J. Tepić

    2011-10-01

    Full Text Available Beginning of production and selling of polymer products largely depends on mold manufacturing. The costs of mold manufacturing have significant share in the final price of a product. The best way to improve and rationalize polymer injection molds production process is by doing mold design automation and manufacturing process planning automation. This paper reviews development of a dedicated process planning system for manufacturing of the mold for injection molding, which integrates computer-aided design (CAD, computer-aided process planning (CAPP and computer-aided manufacturing (CAM technologies.

  18. Computer-aided engineering for Qinshan CANDU projects

    International Nuclear Information System (INIS)

    Huang Zhizhang; Goland, D.

    1999-01-01

    The author briefly describes AECL's work in applying computer-aided engineering tools to the Qinshan CANDU Project. The main emphases will be to introduce the major CADD software tools and their use in civil design, process design and EI and C design. Other special software tools and non-CADD tools and their applications are also briefly introduced

  19. Experiments Using Cell Phones in Physics Classroom Education: The Computer-Aided g Determination

    Science.gov (United States)

    Vogt, Patrik; Kuhn, Jochen; Müller, Sebastian

    2011-09-01

    This paper continues the collection of experiments that describe the use of cell phones as experimental tools in physics classroom education.1-4 We describe a computer-aided determination of the free-fall acceleration g using the acoustical Doppler effect. The Doppler shift is a function of the speed of the source. Since a free-falling objects speed is changing linearly with time, the Doppler shift is also changing with time. It is possible to measure this shift using software that is both easy to use and readily available. Students will use the time-dependency of the Doppler shift to experimentally determine the acceleration due to gravity by using a cell phone as a freely falling object emitting a sound with constant frequency.

  20. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    Science.gov (United States)

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  1. Computer aided molecular design with combined molecular modeling and group contribution

    DEFF Research Database (Denmark)

    Harper, Peter Mathias; Gani, Rafiqul; Kolar, Petr

    1999-01-01

    Computer-aided molecular design (CAMD) provides a means for determining molecules or mixtures of molecules (CAMMD) having a desirable set of physicochemical properties. The application range of CAMD is restricted due to limitations on the complexity of the generated molecular structures and on th......Computer-aided molecular design (CAMD) provides a means for determining molecules or mixtures of molecules (CAMMD) having a desirable set of physicochemical properties. The application range of CAMD is restricted due to limitations on the complexity of the generated molecular structures...

  2. Computer-Aided Multiscale Modelling for Chemical Process Engineering

    DEFF Research Database (Denmark)

    Morales Rodriguez, Ricardo; Gani, Rafiqul

    2007-01-01

    Chemical processes are generally modeled through monoscale approaches, which, while not adequate, satisfy a useful role in product-process design. In this case, use of a multi-dimensional and multi-scale model-based approach has importance in product-process development. A computer-aided framework...

  3. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system

    Science.gov (United States)

    das Neves, Flávio Domingues; de Almeida Prado Naves Carneiro, Thiago; do Prado, Célio Jesus; Prudente, Marcel Santana; Zancopé, Karla; Davi, Letícia Resende; Mendonça, Gustavo; Soares, Carlos José

    2014-08-01

    The current study evaluated prosthetic dental crowns obtained by optical scanning and a computer-aided designing/computer-aided manufacturing system using micro-computed tomography to compare the marginal fit. The virtual models were obtained with four different scanning surfaces: typodont (T), regular impressions (RI), master casts (MC), and powdered master casts (PMC). Five virtual models were obtained for each group. For each model, a crown was designed on the software and milled from feldspathic ceramic blocks. Micro-CT images were obtained for marginal gap measurements and the data were statistically analyzed by one-way analysis of variance followed by Tukey's test. The mean vertical misfit was T=62.6±65.2 μm; MC=60.4±38.4 μm; PMC=58.1±38.0 μm, and RI=89.8±62.8 μm. Considering a percentage of vertical marginal gap of up to 75 μm, the results were T=71.5%, RI=49.2%, MC=69.6%, and PMC=71.2%. The percentages of horizontal overextension were T=8.5%, RI=0%, MC=0.8%, and PMC=3.8%. Based on the results, virtual model acquisition by scanning the typodont (simulated mouth) or MC, with or without powder, showed acceptable values for the marginal gap. The higher result of marginal gap of the RI group suggests that it is preferable to scan this directly from the mouth or from MC.

  4. The potential impact of computer-aided assessment technology in ...

    African Journals Online (AJOL)

    The potential impact of computer-aided assessment technology in higher education. ... Further more 'Increased number of students in Higher Education and the ... benefits, limitations, impacts on student learning and strategies for developing ...

  5. Computer-aided control system design

    International Nuclear Information System (INIS)

    Lebenhaft, J.R.

    1986-01-01

    Control systems are typically implemented using conventional PID controllers, which are then tuned manually during plant commissioning to compensate for interactions between feedback loops. As plants increase in size and complexity, such controllers can fail to provide adequate process regulations. Multivariable methods can be utilized to overcome these limitations. At the Chalk River Nuclear Laboratories, modern control systems are designed and analyzed with the aid of MVPACK, a system of computer programs that appears to the user like a high-level calculator. The software package solves complicated control problems, and provides useful insight into the dynamic response and stability of multivariable systems

  6. Computer-aided dispatching system design specification

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, M.G.

    1997-12-16

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol Operations Center. This document reflects the as-built requirements for the system that was delivered by GTE Northwest, Inc. This system provided a commercial off-the-shelf computer-aided dispatching system and alarm monitoring system currently in operations at the Hanford Patrol Operations Center, Building 2721E. This system also provides alarm back-up capability for the Plutonium Finishing Plant (PFP).

  7. Computer-aided dispatching system design specification

    International Nuclear Information System (INIS)

    Briggs, M.G.

    1997-01-01

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol Operations Center. This document reflects the as-built requirements for the system that was delivered by GTE Northwest, Inc. This system provided a commercial off-the-shelf computer-aided dispatching system and alarm monitoring system currently in operations at the Hanford Patrol Operations Center, Building 2721E. This system also provides alarm back-up capability for the Plutonium Finishing Plant (PFP)

  8. Computer-Aided Communication Satellite System Analysis and Optimization.

    Science.gov (United States)

    Stagl, Thomas W.; And Others

    Various published computer programs for fixed/broadcast communication satellite system synthesis and optimization are discussed. The rationale for selecting General Dynamics/Convair's Satellite Telecommunication Analysis and Modeling Program (STAMP) in modified form to aid in the system costing and sensitivity analysis work in the Program on…

  9. How hearing aids, background noise, and visual cues influence objective listening effort.

    Science.gov (United States)

    Picou, Erin M; Ricketts, Todd A; Hornsby, Benjamin W Y

    2013-09-01

    The purpose of this article was to evaluate factors that influence the listening effort experienced when processing speech for people with hearing loss. Specifically, the change in listening effort resulting from introducing hearing aids, visual cues, and background noise was evaluated. An additional exploratory aim was to investigate the possible relationships between the magnitude of listening effort change and individual listeners' working memory capacity, verbal processing speed, or lipreading skill. Twenty-seven participants with bilateral sensorineural hearing loss were fitted with linear behind-the-ear hearing aids and tested using a dual-task paradigm designed to evaluate listening effort. The primary task was monosyllable word recognition and the secondary task was a visual reaction time task. The test conditions varied by hearing aids (unaided, aided), visual cues (auditory-only, auditory-visual), and background noise (present, absent). For all participants, the signal to noise ratio was set individually so that speech recognition performance in noise was approximately 60% in both the auditory-only and auditory-visual conditions. In addition to measures of listening effort, working memory capacity, verbal processing speed, and lipreading ability were measured using the Automated Operational Span Task, a Lexical Decision Task, and the Revised Shortened Utley Lipreading Test, respectively. In general, the effects measured using the objective measure of listening effort were small (~10 msec). Results indicated that background noise increased listening effort, and hearing aids reduced listening effort, while visual cues did not influence listening effort. With regard to the individual variables, verbal processing speed was negatively correlated with hearing aid benefit for listening effort; faster processors were less likely to derive benefit. Working memory capacity, verbal processing speed, and lipreading ability were related to benefit from visual cues. No

  10. A Computer-Aided FPS-Oriented Approach for Construction Briefing

    Institute of Scientific and Technical Information of China (English)

    Xiaochun Luo; Qiping Shen

    2008-01-01

    Function performance specification (FPS) is one of the value management (VM) techniques de- veloped for the explicit statement of optimum product definition. This technique is widely used in software engineering and manufacturing industry, and proved to be successful to perform product defining tasks. This paper describes an FPS-odented approach for construction briefing, which is critical to the successful deliv- ery of construction projects. Three techniques, i.e., function analysis system technique, shared space, and computer-aided toolkit, are incorporated into the proposed approach. A computer-aided toolkit is developed to facilitate the implementation of FPS in the briefing processes. This approach can facilitate systematic, ef- ficient identification, clarification, and representation of client requirements in trail running. The limitations of the approach and future research work are also discussed at the end of the paper.

  11. Computational reduction techniques for numerical vibro-acoustic analysis of hearing aids

    DEFF Research Database (Denmark)

    Creixell Mediante, Ester

    . In this thesis, several challenges encountered in the process of modelling and optimizing hearing aids are addressed. Firstly, a strategy for modelling the contacts between plastic parts for harmonic analysis is developed. Irregularities in the contact surfaces, inherent to the manufacturing process of the parts....... Secondly, the applicability of Model Order Reduction (MOR) techniques to lower the computational complexity of hearing aid vibro-acoustic models is studied. For fine frequency response calculation and optimization, which require solving the numerical model repeatedly, a computational challenge...... is encountered due to the large number of Degrees of Freedom (DOFs) needed to represent the complexity of the hearing aid system accurately. In this context, several MOR techniques are discussed, and an adaptive reduction method for vibro-acoustic optimization problems is developed as a main contribution. Lastly...

  12. Computer-Aided Transformation of PDE Models: Languages, Representations, and a Calculus of Operations

    Science.gov (United States)

    2016-01-05

    Computer-aided transformation of PDE models: languages, representations, and a calculus of operations A domain-specific embedded language called...languages, representations, and a calculus of operations Report Title A domain-specific embedded language called ibvp was developed to model initial...Computer-aided transformation of PDE models: languages, representations, and a calculus of operations 1 Vision and background Physical and engineered systems

  13. Automatic computer aided analysis algorithms and system for adrenal tumors on CT images.

    Science.gov (United States)

    Chai, Hanchao; Guo, Yi; Wang, Yuanyuan; Zhou, Guohui

    2017-12-04

    The adrenal tumor will disturb the secreting function of adrenocortical cells, leading to many diseases. Different kinds of adrenal tumors require different therapeutic schedules. In the practical diagnosis, it highly relies on the doctor's experience to judge the tumor type by reading the hundreds of CT images. This paper proposed an automatic computer aided analysis method for adrenal tumors detection and classification. It consisted of the automatic segmentation algorithms, the feature extraction and the classification algorithms. These algorithms were then integrated into a system and conducted on the graphic interface by using MATLAB Graphic user interface (GUI). The accuracy of the automatic computer aided segmentation and classification reached 90% on 436 CT images. The experiments proved the stability and reliability of this automatic computer aided analytic system.

  14. The Development of Computer-Aided Design for Electrical Equipment Selection and Arrangement of 10 Kv Switchgear

    Directory of Open Access Journals (Sweden)

    Chernaya Anastassiya

    2015-01-01

    Full Text Available The paper intends to give an overview of a computer-aided design program application. The research includes two main parts: the development of a computer-aided design for an appropriate switchgear selection and its arrangement in an indoor switchgear layout. Matlab program was used to develop a computer-aided design system. The use of this program considerably simplifies the selection and arrangement of 10 kV switchgear.

  15. [Objective and subjective knowledge of HIV/AIDS as predictor of condom use in adolescents].

    Science.gov (United States)

    Villaseñor-Sierra, Alberto; Caballero-Hoyos, Ramiro; Hidalgo-San Martín, Alfredo; Santos-Preciado, José Ignacio

    2003-01-01

    To evaluate the association between objective and subjective knowledge on HIV/AIDS and condom use. Analysis of a database from an anonymous, self-applied, randomized survey conducted between 1995 and 1996. Study subjects were 1,410 adolescents of four socioeconomic strata from Guadalajara, Mexico. Objective knowledge was assessed with 24 questions regarding HIV/AIDS, and subjective knowledge with the question "how much do you think you know about HIV/AIDS?" The variables associated with condom use were identified using logistic regression analysis and by calculating odds ratios with a 95% confidence interval. The degree of objective knowledge was "average", differentiated by socioeconomic strata (p subjective knowledge, adolescents from the low, medium, and high socioeconomic strata claimed to know "a little", and the ones from the lowest stratum claimed to know "very little". Condom use was higher in males (35.4%), and in adolescents from high socioeconomic strata (p objective and subjective knowledge (r = 0.37, p subjective knowledge was associated with condom use (p Subjective knowledge, belonging to medium and high socioeconomic strata and being male, were predictors of condom use.

  16. A new decomposition-based computer-aided molecular/mixture design methodology for the design of optimal solvents and solvent mixtures

    DEFF Research Database (Denmark)

    Karunanithi, A.T.; Achenie, L.E.K.; Gani, Rafiqul

    2005-01-01

    This paper presents a novel computer-aided molecular/mixture design (CAMD) methodology for the design of optimal solvents and solvent mixtures. The molecular/mixture design problem is formulated as a mixed integer nonlinear programming (MINLP) model in which a performance objective is to be optim......This paper presents a novel computer-aided molecular/mixture design (CAMD) methodology for the design of optimal solvents and solvent mixtures. The molecular/mixture design problem is formulated as a mixed integer nonlinear programming (MINLP) model in which a performance objective...... is to be optimized subject to structural, property, and process constraints. The general molecular/mixture design problem is divided into two parts. For optimal single-compound design, the first part is solved. For mixture design, the single-compound design is first carried out to identify candidates...... and then the second part is solved to determine the optimal mixture. The decomposition of the CAMD MINLP model into relatively easy to solve subproblems is essentially a partitioning of the constraints from the original set. This approach is illustrated through two case studies. The first case study involves...

  17. Comparison of gray-scale contrast-enhanced ultrasonography with contrast-enhanced computed tomography in different grading of blunt hepatic and splenic trauma: an animal experiment.

    Science.gov (United States)

    Tang, Jie; Li, Wenxiu; Lv, Faqin; Zhang, Huiqin; Zhang, Lihai; Wang, Yuexiang; Li, Junlai; Yang, Li

    2009-04-01

    To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with contrast-enhanced computed tomography (CECT) for the detection of different grading of solid organ injuries in blunt abdominal trauma in animals. A self-made miniature tools were used as models to simulate a blunt hepatic or splenic trauma in 16 and 14 anesthetized dogs, respectively. Baseline ultrasound, CEUS and CECT were used to detect traumatic injuries of livers and spleens. The degree of injuries was determined by CEUS according to the American Association for the Surgery of Trauma (AAST) scale and the results compared with injury scale based on CECT evaluation. CEUS showed 22 hepatic injury sites in 16 animals and 17 splenic injury sites in other 14 animals. According to AAST scale, 2 grade I, 4 grade II, 3 grade III, 5 grade IV and 2 grade V hepatic lesions were present in 16 animals; 2 grade I, 4 grade II, 6 grade III and 2 grade IV splenic lesions in 14 animals. On CECT scan, 21 hepatic and 17 splenic injuries were demonstrated. According to Becker CT scaling for hepatic injury, 1 grade I, 2 grade II, 4 grade III, 5 grade IV and 2 grade V hepatic injuries were present. On the basis of Buntain spleen scaling, 2 grade I, 5 grade II, 5 grade III, 2 grade IV splenic injuries were showed. After Spearman rank correlation analysis, the agreement of CEUS with CECT on the degree of hepatic and splenic injury is 93.3% and 92.9%, respectively. CT is currently considered as the reference method for grading blunt abdominal trauma, according to experiment results, CEUS grading showed high levels of concordance with CECT. CEUS can accurately determine the degree of injury and will play an important role in clinical application.

  18. The Effects of Computer-Aided Design Software on Engineering Students' Spatial Visualisation Skills

    Science.gov (United States)

    Kösa, Temel; Karakus, Fatih

    2018-01-01

    The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations…

  19. Virtual Reality versus Computer-Aided Exposure Treatments for Fear of Flying

    Science.gov (United States)

    Tortella-Feliu, Miquel; Botella, Cristina; Llabres, Jordi; Breton-Lopez, Juana Maria; del Amo, Antonio Riera; Banos, Rosa M.; Gelabert, Joan M.

    2011-01-01

    Evidence is growing that two modalities of computer-based exposure therapies--virtual reality and computer-aided psychotherapy--are effective in treating anxiety disorders, including fear of flying. However, they have not yet been directly compared. The aim of this study was to analyze the efficacy of three computer-based exposure treatments for…

  20. [Three-dimensional computer aided design for individualized post-and-core restoration].

    Science.gov (United States)

    Gu, Xiao-yu; Wang, Ya-ping; Wang, Yong; Lü, Pei-jun

    2009-10-01

    To develop a method of three-dimensional computer aided design (CAD) of post-and-core restoration. Two plaster casts with extracted natural teeth were used in this study. The extracted teeth were prepared and scanned using tomography method to obtain three-dimensional digitalized models. According to the basic rules of post-and-core design, posts, cores and cavity surfaces of the teeth were designed using the tools for processing point clouds, curves and surfaces on the forward engineering software of Tanglong prosthodontic system. Then three-dimensional figures of the final restorations were corrected according to the configurations of anterior teeth, premolars and molars respectively. Computer aided design of 14 post-and-core restorations were finished, and good fitness between the restoration and the three-dimensional digital models were obtained. Appropriate retention forms and enough spaces for the full crown restorations can be obtained through this method. The CAD of three-dimensional figures of the post-and-core restorations can fulfill clinical requirements. Therefore they can be used in computer-aided manufacture (CAM) of post-and-core restorations.

  1. A Computer-Aided Diagnosis System for Breast Cancer Combining Mammography and Proteomics

    Science.gov (United States)

    2007-05-01

    for sonography,” Ultrasound Med. Biol. 26, 405-411 2000. 20K. Horsch, M. L. Giger, L. A. Venta , and C. J. Vyborny, “Computerized diagnosis of breast...lesions on ultrasound,” Med. Phys. 29, 157-164 2002. 21K. Horsch, M. L. Giger, C. J. Vyborny, and L. A. Venta , “Performance of computer-aided...Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography. Acad Radiol

  2. Costs incurred by applying computer-aided design/computer-aided manufacturing techniques for the reconstruction of maxillofacial defects.

    Science.gov (United States)

    Rustemeyer, Jan; Melenberg, Alex; Sari-Rieger, Aynur

    2014-12-01

    This study aims to evaluate the additional costs incurred by using a computer-aided design/computer-aided manufacturing (CAD/CAM) technique for reconstructing maxillofacial defects by analyzing typical cases. The medical charts of 11 consecutive patients who were subjected to the CAD/CAM technique were considered, and invoices from the companies providing the CAD/CAM devices were reviewed for every case. The number of devices used was significantly correlated with cost (r = 0.880; p costs were found between cases in which prebent reconstruction plates were used (€3346.00 ± €29.00) and cases in which they were not (€2534.22 ± €264.48; p costs of two, three and four devices, even when ignoring the cost of reconstruction plates. Additional fees provided by statutory health insurance covered a mean of 171.5% ± 25.6% of the cost of the CAD/CAM devices. Since the additional fees provide financial compensation, we believe that the CAD/CAM technique is suited for wide application and not restricted to complex cases. Where additional fees/funds are not available, the CAD/CAM technique might be unprofitable, so the decision whether or not to use it remains a case-to-case decision with respect to cost versus benefit. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. The Research of Computer Aided Farm Machinery Designing Method Based on Ergonomics

    Science.gov (United States)

    Gao, Xiyin; Li, Xinling; Song, Qiang; Zheng, Ying

    Along with agricultural economy development, the farm machinery product type Increases gradually, the ergonomics question is also getting more and more prominent. The widespread application of computer aided machinery design makes it possible that farm machinery design is intuitive, flexible and convenient. At present, because the developed computer aided ergonomics software has not suitable human body database, which is needed in view of farm machinery design in China, the farm machinery design have deviation in ergonomics analysis. This article puts forward that using the open database interface procedure in CATIA to establish human body database which aims at the farm machinery design, and reading the human body data to ergonomics module of CATIA can product practical application virtual body, using human posture analysis and human activity analysis module to analysis the ergonomics in farm machinery, thus computer aided farm machinery designing method based on engineering can be realized.

  4. Computer Aided Multi-Data Fusion Dismount Modeling

    Science.gov (United States)

    2012-03-22

    dependent on a particular environmental condition. They are costly, cumbersome, and involve dedicated software practices and particular knowledge to operate...allow manipulation of 2D matrices, like Microsoft Excel or Libre Office. The second alternative is to modify an already created model (MEM). The model... software . Therefore, with the described computer aided multi-data dismount model the researcher will be able to attach signatures to any desired

  5. Computer-Aided College Algebra: Learning Components that Students Find Beneficial

    Science.gov (United States)

    Aichele, Douglas B.; Francisco, Cynthia; Utley, Juliana; Wescoatt, Benjamin

    2011-01-01

    A mixed-method study was conducted during the Fall 2008 semester to better understand the experiences of students participating in computer-aided instruction of College Algebra using the software MyMathLab. The learning environment included a computer learning system for the majority of the instruction, a support system via focus groups (weekly…

  6. Computer aided control engineering

    DEFF Research Database (Denmark)

    Szymkat, Maciej; Ravn, Ole

    1997-01-01

    Current developments in the field of Computer Aided Control Engineering (CACE) have a visible impact on the design methodologies and the structure of the software tools supporting them. Today control engineers has at their disposal libraries, packages or programming environments that may...... in CACE enhancing efficient flow of information between the tools supporting the following phases of the design process. In principle, this flow has to be two-way, and more or less automated, in order to enable the engineer to observe the propagation of the particular design decisions taken at various...... levels.The major conclusions of the paper are related with identifying the factors affecting the software tool integration in a way needed to facilitate design "inter-phase" communication. These are: standard application interfaces, dynamic data exchange mechanisms, code generation techniques and general...

  7. X-ray and gamma-ray transmission computed tomographic imaging of archaeological objects

    International Nuclear Information System (INIS)

    Jaafar Abdullah; Susan Maria Sipaun

    2004-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-section images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography or computed-aided tomography. The invention of CT techniques revolutionised the field of medical diagnostic imaging because it provided more detailed and useful information than any previous non-invasive imaging techniques. The method is increasingly being used in industry, aerospace, geosciences and archaeology. This paper presents a brief overview of X-ray or gamma-ray transmission tomography. It is not intended to be a technical treatise but is hoped that it would raise awareness and promote opportunities for further collaboration amongst the nuclear research community, including archaeologists and those in the conservation profession. The theoretical aspects of CT scanner, the system configurations and the adopted algorithm for image reconstruction are discussed. In addition, a few examples of CT images for archaeological objects are presented. The examples were purposely chosen to illustrate clearly and precisely the fundamental concepts of this sophisticated field. (Author)

  8. Computer-Aided Detection of Polyps in CT Colonography Using Logistic Regression

    NARCIS (Netherlands)

    Van Ravesteijn, V.F.; Van Wijk, C.; Vos, F.M.; Truyen, R.; Peters, J.F.; Stoker, J.; Van Vliet, L.J.

    2010-01-01

    We present a computer-aided detection (CAD) system for computed tomography colonography that orders the polyps according to clinical relevance. TheCADsystem consists of two steps: candidate detection and supervised classification. The characteristics of the detection step lead to specific choices

  9. Computer-Aided Test Flow in Core-Based Design

    NARCIS (Netherlands)

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the test-pattern generation and fault coverage determination in the core based design. The basic core-test strategy that one has to apply in the core-based design is stated in this work. A Computer-Aided Test (CAT) flow is proposed resulting in accurate fault coverage of

  10. Remineralization potential of nano-hydroxyapatite on enamel and cementum surrounding margin of computer-aided design and computer-aided manufacturing ceramic restoration

    Science.gov (United States)

    Juntavee, Niwut; Juntavee, Apa; Plongniras, Preeyarat

    2018-01-01

    Objective This study investigates the effects of nano-hydroxyapatite (NHA) gel and Clinpro (CP) on remineralization potential of enamel and cementum at the cavosurface area of computer-aided design and computer-aided manufacturing ceramic restoration. Materials and methods Thirty extracted human mandibular third molars were sectioned at 1 mm above and below the cemento–enamel junction to remove the cemento–enamel junction portions and replaced them with zirconia ceramic disks by bonding them to the crown and root portions with resin cement. The enamel and cementum with an area of 4×4 mm2 surrounding the ceramic disk was demineralized with carbopol. The demineralized surfaces were treated with either NHA or CP, while 1 group was left with no treatment. Vickers microhardness of enamel and cementum were determined before demineralization, after demineralization, and after remineralization. Analysis of variance and Tukey multiple comparisons were used to determine statistically significant differences at 95% level of confidence. Scanning electron microscopy and X-ray diffraction were used to evaluate for surface alterations. Results The mean ± SD of Vickers microhardness for before demineralization, after demineralization, and after remineralization for enamel and cementum were 377.37±22.99, 161.95±10.54, 161.70±5.92 and 60.37±3.81, 17.65±0.91, 17.04±1.00 for the no treatment group; 378.20±18.76, 160.72±8.38, 200.08±8.29 and 62.58±3.37, 18.38±1.33, 27.99±2.68 for the NHA groups; and 380.53±25.14, 161.94±5.66, 193.16±7.54 and 62.78±4.75, 19.07±1.30, 24.46±2.02 for the CP groups. Analysis of variance indicated significant increase in microhardness of demineralized enamel and cementum upon the application of either NHA or CP (pmanufacturing ceramic. PMID:29780246

  11. Computer-Aided Test Flow in Core-Based Design

    NARCIS (Netherlands)

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the efficient test-pattern generation in a core-based design. A consistent Computer-Aided Test (CAT) flow is proposed based on the required core-test strategy. It generates a test-pattern set for the embedded cores with high fault coverage and low DfT area overhead. The CAT

  12. New tools to aid in scientific computing and visualization

    International Nuclear Information System (INIS)

    Wallace, M.G.; Christian-Frear, T.L.

    1992-01-01

    In this paper, two computer programs are described which aid in the pre- and post-processing of computer generated data. CoMeT (Computational Mechanics Toolkit) is a customizable, interactive, graphical, menu-driven program that provides the analyst with a consistent user-friendly interface to analysis codes. Trans Vol (Transparent Volume Visualization) is a specialized tool for the scientific three-dimensional visualization of complex solids by the technique of volume rendering. Both tools are described in basic detail along with an application example concerning the simulation of contaminant migration from an underground nuclear repository

  13. Effect of Computer-Presented Organizational/Memory Aids on Problem Solving Behavior.

    Science.gov (United States)

    Steinberg, Esther R.; And Others

    This research studied the effects of computer-presented organizational/memory aids on problem solving behavior. The aids were either matrix or verbal charts shown on the display screen next to the problem. The 104 college student subjects were randomly assigned to one of the four conditions: type of chart (matrix or verbal chart) and use of charts…

  14. Computer Aided Design Tools for Extreme Environment Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project aims to provide Computer Aided Design (CAD) tools for radiation-tolerant, wide-temperature-range digital, analog, mixed-signal, and radio-frequency...

  15. Computer-aided system for diabetes care in Berlin, G.D.R.

    Science.gov (United States)

    Thoelke, H; Meusel, K; Ratzmann, K P

    1990-01-01

    In the Centre of Diabetes and Metabolic Disorders of Berlin, G.D.R., a computer-aided care system has been used since 1974, aiming at relieving physicians and medical staff from routine tasks and rendering possible epidemiological research on an unselected diabetes population of a defined area. The basis of the system is the data bank on diabetics (DB), where at present data from approximately 55,000 patients are stored. DB is used as a diabetes register of Berlin. On the basis of standardised criteria of diagnosis and therapy of diabetes mellitus in our dispensary care system, DB facilitates representative epidemiological analyses of the diabetic population, e.g. prevalence, incidence, duration of diabetes, and modes of treatment. The availability of general data on the population or the selection of specified groups of patients serves the management of the care system. Also, it supports the computer-aided recall of type II diabetics, treated either with diet alone or with diet and oral drugs. In this way, the standardised evaluation of treatment strategies in large populations of diabetics is possible on the basis of uniform metabolic criteria (blood glucose plus urinary glucose). The system consists of a main computer in the data processing unit and of personal computers in the diabetes centre which can be used either individually or as terminals to the main computer. During 14 years of experience, the computer-aided out-patient care of type II diabetics has proved efficient in a big-city area with a large population.

  16. Critics raise moral objections to Federal AIDS education classes.

    Science.gov (United States)

    1995-07-28

    Lawmakers and a handful of government employees have objected to the Federal government's programs to educate its employees about AIDS. At the June 22, 1995 hearing of the civil service subcommittee of the House Government Reform and Oversight Committee, protests were raised on religious or moral grounds. Thomas Herron, a supervisory logistics manager at the Naval Air Technical Services Facility in Philadelphia found the training to be against the principles of his faith. Rep. Robert K. Dornan (R-Calif) said his office was flooded with calls and letters from employees who raised concern that the training is being used to advance a redefinition of the family and is a blatant pro-homosexual agenda. Robert L. Maginnis, policy analyst for the conservative Family Research Council, faulted the training, saying it does little to change behavior that puts people at risk for HIV infection. Clinton administration officials testified at the meeting that the program is necessary to ensure both the safety of the workforce and employees' freedom from discrimination and harassment. Individual departments and agencies are responsible for developing their own AIDS training programs. According to Alan Heuerman, associate director for human resource systems service with the Office of Personnel Management, relatively few objections have been raised about the training.

  17. Topology optimization aided structural design: Interpretation, computational aspects and 3D printing.

    Science.gov (United States)

    Kazakis, Georgios; Kanellopoulos, Ioannis; Sotiropoulos, Stefanos; Lagaros, Nikos D

    2017-10-01

    Construction industry has a major impact on the environment that we spend most of our life. Therefore, it is important that the outcome of architectural intuition performs well and complies with the design requirements. Architects usually describe as "optimal design" their choice among a rather limited set of design alternatives, dictated by their experience and intuition. However, modern design of structures requires accounting for a great number of criteria derived from multiple disciplines, often of conflicting nature. Such criteria derived from structural engineering, eco-design, bioclimatic and acoustic performance. The resulting vast number of alternatives enhances the need for computer-aided architecture in order to increase the possibility of arriving at a more preferable solution. Therefore, the incorporation of smart, automatic tools in the design process, able to further guide designer's intuition becomes even more indispensable. The principal aim of this study is to present possibilities to integrate automatic computational techniques related to topology optimization in the phase of intuition of civil structures as part of computer aided architectural design. In this direction, different aspects of a new computer aided architectural era related to the interpretation of the optimized designs, difficulties resulted from the increased computational effort and 3D printing capabilities are covered here in.

  18. Computer-aided cleanup

    International Nuclear Information System (INIS)

    Williams, J.; Jones, B.

    1994-01-01

    In late 1992, the remedial investigation of operable unit 2 at the Department of Energy (DOE) Superfund site in Fernald, Ohio was in trouble. Despite years of effort--including an EPA-approved field-investigation work plan, 123 soil borings, 51 ground-water-monitoring wells, analysis of more than 650 soil and ground-water samples, and preparation of a draft remedial-investigation (RI) report--it was not possible to conclude if contaminated material in the unit was related to ground-water contamination previously detected beneath and beyond the site boundary. Compounding the problem, the schedule for the RI, feasibility study and record of decision for operable unit 2 was governed by a DOE-EPA consent agreement stipulating penalties of up to $10,000 per week for not meeting scheduled milestones--and time was running out. An advanced three-dimensional computer model confirmed that radioactive wastes dumped at the Fernald, Ohio Superfund site had contaminated ground water, after years of previous testing has been inconclusive. The system is now being used to aid feasibility and design work on the more-than-$1 billion remediation project

  19. Critiquing the Computer-Aided Design of Dental Prostheses.

    Science.gov (United States)

    Fitzpatrick, F. J.; And Others

    This paper describes RaPiD, a computer-aided assistant for the design of dental prostheses called removable partial dentures. The user manipulates icons directly to indicate the desired design solution to a given clinical situation. A developing design is represented as a logic database of components in a design; expert rules are applied as…

  20. DEVELOPMENT OF COMPUTER AIDED DESIGN OF CHAIN COUPLING

    Directory of Open Access Journals (Sweden)

    Sergey Aleksandrovich Sergeev

    2015-12-01

    Full Text Available The present paper describes the development stages of computer-aided design of chain couplings. The first stage is the automation of traditional design techniques (intermediate automation. The second integrated automation with the development of automated equipment and production technology, including on the basis of flexible manufacturing systems (high level of automation.

  1. Computer Aided Battery Engineering Consortium

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, Ahmad

    2016-06-07

    A multi-national lab collaborative team was assembled that includes experts from academia and industry to enhance recently developed Computer-Aided Battery Engineering for Electric Drive Vehicles (CAEBAT)-II battery crush modeling tools and to develop microstructure models for electrode design - both computationally efficient. Task 1. The new Multi-Scale Multi-Domain model framework (GH-MSMD) provides 100x to 1,000x computation speed-up in battery electrochemical/thermal simulation while retaining modularity of particles and electrode-, cell-, and pack-level domains. The increased speed enables direct use of the full model in parameter identification. Task 2. Mechanical-electrochemical-thermal (MECT) models for mechanical abuse simulation were simultaneously coupled, enabling simultaneous modeling of electrochemical reactions during the short circuit, when necessary. The interactions between mechanical failure and battery cell performance were studied, and the flexibility of the model for various batteries structures and loading conditions was improved. Model validation is ongoing to compare with test data from Sandia National Laboratories. The ABDT tool was established in ANSYS. Task 3. Microstructural modeling was conducted to enhance next-generation electrode designs. This 3- year project will validate models for a variety of electrodes, complementing Advanced Battery Research programs. Prototype tools have been developed for electrochemical simulation and geometric reconstruction.

  2. Contrast-enhanced ultrasonography and spiral computed tomography in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Sandro; Ghittoni, Giorgia; Ravetta, Valentina; Torello Viera, Francesca; Rosa, Laura [Policlinico ' S. Matteo' Foundation, IRCCS, VI Department of Internal Medicine and Interventional Ultrasonography, Pavia (Italy); Serassi, Martina; Scabini, Mara; Vercelli, Alessandro; Calliada, Fabrizio [IRCCS Policlinico ' S. Matteo' , Department of Radiology, P.le Golgi n. 19, Pavia (Italy); Tinelli, Carmine [Biometrics Unit, IRCCS Policlinico ' S. Matteo' , Pavia (Italy); Dal Bello, Barbara [IRCCS Policlinico ' S. Matteo' , Department of Human Pathology, Pavia (Italy); Burns, Peter N. [University of Toronto, Department of Medical Biophysics, Toronto, ON (Canada); Imaging Research S660, Sunnybrook Health Science Centre, Toronto, ON (Canada)

    2008-08-15

    The aim was to compare the performances of contrast-enhanced (CE) ultrasonography (US) and spiral computed tomography (CT) in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma (HCC). We studied 50 patients with HCC who had biopsy-proven portal vein thrombi that had been detected with US and color Doppler US. Thirteen of the thrombi involved the main portal trunk and 37 the segmental branches. CEUS and CT were performed within a week of thrombus biopsies. For each imaging technique, diagnoses of thrombosis (present/absent) and thrombus nature (malignancy/benignancy) were made by experienced readers under blinded conditions and compared with pathological findings to determine accuracy rates for thrombus detection and characterization. Forty-four of the 50 thrombi were pathologically diagnosed as malignant and the remaining six were benign. CEUS detected 50/50 (100%) thrombi and correctly characterized 49/50 (98%). CT detected 34/50 (68%) thrombi and correctly characterized 23 of these 34 (68%). CEUS outperformed CT in terms of both thrombus detection (P < 0.0001) and characterization (P = 0.0001). CEUS appears to be significantly superior to CT for detection and characterization of portal vein thrombosis complicating HCC, and it should be considered in the staging of these tumors. (orig.)

  3. Database organization for computer-aided characterization of laser diode

    International Nuclear Information System (INIS)

    Oyedokun, Z.O.

    1988-01-01

    Computer-aided data logging involves a huge amount of data which must be properly managed for optimized storage space, easy access, retrieval and utilization. An organization method is developed to enhance the advantages of computer-based data logging of the testing of the semiconductor injection laser which optimize storage space, permit authorized user easy access and inhibits penetration. This method is based on unique file identification protocol tree structure and command file-oriented access procedures

  4. CADMIO: computer aided design for medical information objects.

    Science.gov (United States)

    Minarelli, D V; Ferri, F; Pisanelli, D M; Ricci, F L; Tittarelli, F

    1995-01-01

    The growth of the computational capability and the tools of graphic software is nowadays available in an integrated manner into the development environments, thus permitting the realization of tool kits capable of handling information that is complex and of different kinds such as the typical medical information. This has given a great impulse to the creation of electronic medical folders joining together with new and stimulating functionality with respect to the usual paper document [1]. In the present work, we propose a tool capable of defining a multimedia electronic medical folder and representing its architecture through a layout that is formed on the basis of the particular data types to be handled. This tool is capable of providing an integrated view of data that, even though they are close in cognitive sense, are often stored and represented apart in the practice. Different approaches to the browsing feature are giving within the system, thus the user can personalize the way of viewing the information stored into the folder or can let the system guide the browsing.

  5. Computer-Aided Design Method of Warp-Knitted Jacquard Spacer Fabrics

    Directory of Open Access Journals (Sweden)

    Li Xinxin

    2016-06-01

    Full Text Available Based on a further study on knitting and jacquard principles, this paper presents a mathematical design model to make computer-aided design of warp-knitted jacquard spacer fabrics more efficient. The mathematical model with matrix method employs three essential elements of chain notation, threading and Jacquard designing. With this model, the processing to design warp-knitted jacquard spacer fabrics with CAD software is also introduced. In this study, the sports shoes which have separated functional areas according to the feet structure and characteristics of movement are analysed. The results show the different patterns on Jacquard spacer fabrics that are seamlessly stitched with jacquard technics. The computer-aided design method of warp-knitted jacquard spacer fabrics is efficient and simple.

  6. Study on computer-aided simulation procedure for multicomponent separating cascade

    International Nuclear Information System (INIS)

    Kinoshita, Masahiro

    1982-11-01

    The present report reviews the author's study on the computer-aided simulation procedure for a multicomponent separating cascade. As a conclusion, two very powerful simulation procedures have been developed for cascades composed of separating elements whose separation factors are very large. They are applicable in cases where interstage flow rates are input variables for the calculation and stage separation factors are given either as constants or as functions of compositions of the up and down streams. As an application of the new procedure, a computer-aided simulation study has been performed for hydrogen isotope separating cascades by porous membrane method. A cascade system configuration is developed and pertinent design specifications are determined in an example case of the feed conditions and separation requirements. (author)

  7. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K H; Weber, M; Weiss, M [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1999-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  8. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K.H.; Weber, M.; Weiss, M. [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1998-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  9. Computer-aided Nonlinear Control System Design Using Describing Function Models

    CERN Document Server

    Nassirharand, Amir

    2012-01-01

    A systematic computer-aided approach provides a versatile setting for the control engineer to overcome the complications of controller design for highly nonlinear systems. Computer-aided Nonlinear Control System Design provides such an approach based on the use of describing functions. The text deals with a large class of nonlinear systems without restrictions on the system order, the number of inputs and/or outputs or the number, type or arrangement of nonlinear terms. The strongly software-oriented methods detailed facilitate fulfillment of tight performance requirements and help the designer to think in purely nonlinear terms, avoiding the expedient of linearization which can impose substantial and unrealistic model limitations and drive up the cost of the final product. Design procedures are presented in a step-by-step algorithmic format each step being a functional unit with outputs that drive the other steps. This procedure may be easily implemented on a digital computer with example problems from mecha...

  10. Development of computer-aided auto-ranging technique for a computed radiography system

    International Nuclear Information System (INIS)

    Ishida, M.; Shimura, K.; Nakajima, N.; Kato, H.

    1988-01-01

    For a computed radiography system, the authors developed a computer-aided autoranging technique in which the clinically useful image data are automatically mapped to the available display range. The preread image data are inspected to determine the location of collimation. A histogram of the pixels inside the collimation is evaluated regarding characteristic values such as maxima and minima, and then the optimal density and contrast are derived for the display image. The effect of the autoranging technique was investigated at several hospitals in Japan. The average rate of films lost due to undesirable density or contrast was about 0.5%

  11. Assisted supervision of a computer aided tele-operation system

    Energy Technology Data Exchange (ETDEWEB)

    Le Bars, H; Gravez, P; Fournier, R

    1994-12-31

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs.

  12. Assisted supervision of a computer aided tele-operation system

    International Nuclear Information System (INIS)

    Le Bars, H.; Gravez, P.; Fournier, R.

    1994-01-01

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs

  13. Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology.

    Science.gov (United States)

    Arafa, Khalid A O

    2018-01-01

    To assess the level of evidence that supports the quality of fit for removable partial denture (RPD) fabricated by computer-aided designing/computer aided manufacturing (CAD/CAM) and rapid prototyping (RP) technology. Methods: An electronic search was performed in Google Scholar, PubMed, and Cochrane library search engines, using Boolean operators. All articles published in English and published in the period from 1950 until April 2017 were eligible to be included in this review. The total number of articles contained the search terms in any part of the article (including titles, abstracts, or article texts) were screened, which resulted in 214 articles. After exclusion of irrelevant and duplicated articles, 12 papers were included in this systematic review.  Results: All the included studies were case reports, except one study, which was a case series that recruited 10 study participants. The visual and tactile examination in the cast or clinically in the patient's mouth was the most-used method for assessment of the fit of RPDs. From all included studies, only one has assessed the internal fit between RPDs and oral tissues using silicone registration material. The vast majority of included studies found that the fit of RPDs ranged from satisfactory to excellent fit. Conclusion: Despite the lack of clinical trials that provide strong evidence, the available evidence supported the claim of good fit of RPDs fabricated by new technologies using CAD/CAM.

  14. A Complete Interactive Graphical Computer-Aided Instruction System.

    Science.gov (United States)

    Abrams, Steven Selby

    The use of interactive graphics in computer-aided instruction systems is discussed with emphasis placed on two requirements of such a system. The first is the need to provide the teacher with a useful tool with which to design and modify teaching sessions tailored to the individual needs and capabilities of the students. The second is the…

  15. Caesy: A software tool for computer-aided engineering

    Science.gov (United States)

    Wette, Matt

    1993-01-01

    A new software tool, Caesy, is described. This tool provides a strongly typed programming environment for research in the development of algorithms and software for computer-aided control system design. A description of the user language and its implementation as they currently stand are presented along with a description of work in progress and areas of future work.

  16. Diagnostic accuracy of magnetic resonance, computed tomography and contrast enhanced ultrasound in radiological multimodality assessment of peribiliary liver metastases.

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    Full Text Available We compared diagnostic performance of Magnetic Resonance (MR, Computed Tomography (CT and Ultrasound (US with (CEUS and without contrast medium to identify peribiliary metastasis.We identified 35 subjects with histological proven peribiliary metastases who underwent CEUS, CT and MR study. Four radiologists evaluated the presence of peribiliary lesions, using a 4-point confidence scale. Echogenicity, density and T1-Weigthed (T1-W, T2-W and Diffusion Weighted Imaging (DWI signal intensity as well as the enhancement pattern during contrast studies on CEUS, CT and MR so as hepatobiliary-phase on MRI was assessed.All lesions were detected by MR. CT detected 8 lesions, while US/CEUS detected one lesion. According to the site of the lesion, respect to the bile duct and hepatic parenchyma: 19 (54.3% were periductal, 15 (42.8% were intra-periductal and 1 (2.8% was periductal-intrahepatic. According to the confidence scale MRI had the best diagnostic performance to assess the lesion. CT obtained lower diagnostic performance. There was no significant difference in MR signal intensity and contrast enhancement among all metastases (p>0.05. There was no significant difference in CT density and contrast enhancement among all metastases (p>0.05.MRI is the method of choice for biliary tract tumors but it does not allow a correct differential diagnosis among different histological types of metastasis. The presence of biliary tree dilatation without hepatic lesions on CT and US/CEUS study may be an indirect sign of peribiliary metastases and for this reason the patient should be evaluated by MRI.

  17. Progress in computer aided diagnosis for medical images by information technology

    International Nuclear Information System (INIS)

    Mekada, Yoshito

    2007-01-01

    This paper describes the history, present state and future view of computer aided diagnosis (CAD) based on processing, recognition and visualization of chest and abdominal images. A primitive feature of CAD is seen as early as in 1960's for lung cancer detection. Contemporarily, advances in medical imaging by CT, MRI, single photon emission computed tomography (SPECT) and positron emission tomography (PET) in multi-dimensions require doctors to read those vast information, where necessity of CAD is evident. At present, simultaneous CAD for multi-organs and multi-diseases is in progress, the interaction between images and medical doctors is leading to developing a newer system like virtual endoscopy, objective evaluation of CAD systems is necessary for its approval to authorities like fluorescein diacetate (FDA) with use of receiver operating characteristics analysis, and thus cooperation of medical and technological fields is more and more important. In future, CAD should be responsible for individual difference and for change in disease state, usable simultaneously for time and space, more recognized of its importance by doctors, and more useful in participation to therapeutic practice. (R.T.)

  18. Computer training aids for nuclear operator training

    International Nuclear Information System (INIS)

    Phillips, J.G.P.; Binns, J.B.H.

    1983-01-01

    The Royal Navy's Nuclear Propulsion School at HMS SULTAN which is responsible for training all ratings and officers who operate Submarine Pressurised Water Reactor plants, has available a varied selection of classroom simulator training aids as well as purpose built Submarine Manoeuvring Room simulators. The use of these classroom training aids in the twelve months prior to Autumn 1981 is discussed. The advantages and disadvantages of using relatively expensive computer based aids to support classroom instruction for students who do not investigate mathematically the dynamics of the Reactor Plant are identified. The conclusions drawn indicate that for students of limited academic ability the classroom simulators are disproportionately expensive in cost, maintenance load, and instructional time. Secondly, the experience gained in the use of the Manoeuvring Room Simulators to train future operators who have just finished the academic phase of their training is outlined. The possible pitfalls for the instructor are discussed and the lessons learnt, concluding that these simulators provide a valuable substitute for the live plant enabling trainees to be brought up to a common standard and reducing their on job training time to an acceptable level. (author)

  19. Progress of the Computer-Aided Engineering of Electric Drive Vehicle Batteries (CAEBAT) (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, A. A.; Han, T.; Hartridge, S.; Shaffer, C.; Kim, G. H.; Pannala, S.

    2013-06-01

    This presentation, Progress of Computer-Aided Engineering of Electric Drive Vehicle Batteries (CAEBAT) is about simulation and computer-aided engineering (CAE) tools that are widely used to speed up the research and development cycle and reduce the number of build-and-break steps, particularly in the automotive industry. Realizing this, DOE?s Vehicle Technologies Program initiated the CAEBAT project in April 2010 to develop a suite of software tools for designing batteries.

  20. Computer aided analysis of disturbances

    International Nuclear Information System (INIS)

    Baldeweg, F.; Lindner, A.

    1986-01-01

    Computer aided analysis of disturbances and the prevention of failures (diagnosis and therapy control) in technological plants belong to the most important tasks of process control. Research in this field is very intensive due to increasing requirements to security and economy of process control and due to a remarkable increase of the efficiency of digital electronics. This publication concerns with analysis of disturbances in complex technological plants, especially in so called high risk processes. The presentation emphasizes theoretical concept of diagnosis and therapy control, modelling of the disturbance behaviour of the technological process and the man-machine-communication integrating artificial intelligence methods, e.g., expert system approach. Application is given for nuclear power plants. (author)

  1. Computer-Aided Template for Model Reuse, Development and Maintenance

    DEFF Research Database (Denmark)

    Fedorova, Marina; Sin, Gürkan; Gani, Rafiqul

    2014-01-01

    A template-based approach for model development is presented in this work. Based on a model decomposition technique, the computer-aided template concept has been developed. This concept is implemented as a software tool , which provides a user-friendly interface for following the workflow steps...

  2. Computer aided fault tree synthesis

    International Nuclear Information System (INIS)

    Poucet, A.

    1983-01-01

    Nuclear as well as non-nuclear organisations are showing during the past few years a growing interest in the field of reliability analysis. This urges for the development of powerful, state of the art methods and computer codes for performing such analysis on complex systems. In this report an interactive, computer aided approach is discussed, based on the well known fault tree technique. The time consuming and difficut task of manually constructing a system model (one or more fault trees) is replaced by an efficient interactive procedure in which the flexibility and the learning process inherent to the manual approach are combined with the accuracy in the modelling and the speed of the fully automatical approach. The method presented is based upon the use of a library containing component models. The possibility of setting up a standard library of models of general use and the link with a data collection system are discussed. The method has been implemented in the CAFTS-SALP software package which is described shortly in the report

  3. Computer-Aided Diagnosis of Breast Cancer: A Multi-Center Demonstrator

    National Research Council Canada - National Science Library

    Floyd, Carey

    2000-01-01

    .... The focus has been to gather data from multiple sites in order to verify and whether the artificial neural network computer aid to the diagnosis of breast cancer can be translated between locations...

  4. Computer-Aided Experiment Planning toward Causal Discovery in Neuroscience.

    Science.gov (United States)

    Matiasz, Nicholas J; Wood, Justin; Wang, Wei; Silva, Alcino J; Hsu, William

    2017-01-01

    Computers help neuroscientists to analyze experimental results by automating the application of statistics; however, computer-aided experiment planning is far less common, due to a lack of similar quantitative formalisms for systematically assessing evidence and uncertainty. While ontologies and other Semantic Web resources help neuroscientists to assimilate required domain knowledge, experiment planning requires not only ontological but also epistemological (e.g., methodological) information regarding how knowledge was obtained. Here, we outline how epistemological principles and graphical representations of causality can be used to formalize experiment planning toward causal discovery. We outline two complementary approaches to experiment planning: one that quantifies evidence per the principles of convergence and consistency, and another that quantifies uncertainty using logical representations of constraints on causal structure. These approaches operationalize experiment planning as the search for an experiment that either maximizes evidence or minimizes uncertainty. Despite work in laboratory automation, humans must still plan experiments and will likely continue to do so for some time. There is thus a great need for experiment-planning frameworks that are not only amenable to machine computation but also useful as aids in human reasoning.

  5. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration.

    Science.gov (United States)

    Juntavee, Niwut; Sirisathit, Issarawas

    2018-01-01

    This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel-chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey's honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system ( p marginal gap than the conventional cast metal restoration ( p marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration.

  6. Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems.

    Science.gov (United States)

    Park, Jong-Kyoung; Lee, Wan-Sun; Kim, Hae-Young; Kim, Woong-Chul; Kim, Ji-Hwan

    2015-04-01

    To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

  7. Computer-aided detection systems to improve lung cancer early diagnosis: state-of-the-art and challenges

    International Nuclear Information System (INIS)

    Traverso, A; Lopez Torres, E; Cerello, P; Fantacci, M E

    2017-01-01

    Lung cancer is one of the most lethal types of cancer, because its early diagnosis is not good enough. In fact, the detection of pulmonary nodule, potential lung cancers, in Computed Tomography scans is a very challenging and time-consuming task for radiologists. To support radiologists, researchers have developed Computer-Aided Diagnosis (CAD) systems for the automated detection of pulmonary nodules in chest Computed Tomography scans. Despite the high level of technological developments and the proved benefits on the overall detection performance, the usage of Computer-Aided Diagnosis in clinical practice is far from being a common procedure. In this paper we investigate the causes underlying this discrepancy and present a solution to tackle it: the M5L WEB- and Cloud-based on-demand Computer-Aided Diagnosis. In addition, we prove how the combination of traditional imaging processing techniques with state-of-art advanced classification algorithms allows to build a system whose performance could be much larger than any Computer-Aided Diagnosis developed so far. This outcome opens the possibility to use the CAD as clinical decision support for radiologists. (paper)

  8. Computer-aided detection systems to improve lung cancer early diagnosis: state-of-the-art and challenges

    Science.gov (United States)

    Traverso, A.; Lopez Torres, E.; Fantacci, M. E.; Cerello, P.

    2017-05-01

    Lung cancer is one of the most lethal types of cancer, because its early diagnosis is not good enough. In fact, the detection of pulmonary nodule, potential lung cancers, in Computed Tomography scans is a very challenging and time-consuming task for radiologists. To support radiologists, researchers have developed Computer-Aided Diagnosis (CAD) systems for the automated detection of pulmonary nodules in chest Computed Tomography scans. Despite the high level of technological developments and the proved benefits on the overall detection performance, the usage of Computer-Aided Diagnosis in clinical practice is far from being a common procedure. In this paper we investigate the causes underlying this discrepancy and present a solution to tackle it: the M5L WEB- and Cloud-based on-demand Computer-Aided Diagnosis. In addition, we prove how the combination of traditional imaging processing techniques with state-of-art advanced classification algorithms allows to build a system whose performance could be much larger than any Computer-Aided Diagnosis developed so far. This outcome opens the possibility to use the CAD as clinical decision support for radiologists.

  9. A computer-aided molecular design framework for crystallization solvent design

    DEFF Research Database (Denmark)

    Karunanithi, Arunprakash T.; Achenie, Luke E.K.; Gani, Rafiqul

    2006-01-01

    One of the key decisions in designing solution crystallization processes is the selection of solvents. In this paper, we present a computer-aided molecular design (CAMD) framework for the design and selection of solvents and/or anti-solvents for solution crystallization. The CAMD problem is formu......One of the key decisions in designing solution crystallization processes is the selection of solvents. In this paper, we present a computer-aided molecular design (CAMD) framework for the design and selection of solvents and/or anti-solvents for solution crystallization. The CAMD problem...... solvent molecules. Solvent design and selection for two types of solution crystallization processes namely cooling crystallization and drowning out crystallization are presented. In the first case study, the design of single compound solvent for crystallization of ibuprofen, which is an important...

  10. Chapter 6 – Computer-Aided Molecular Design and Property Prediction

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Zhang, L.; Kalakul, Sawitree

    2017-01-01

    for the initial stages of the design/development process. Therefore, computer-aided molecular design and property prediction techniques are two topics that play important roles in chemical product design, analysis, and application. In this chapter, an overview of the concepts, methods, and tools related......Today's society needs many chemical-based products for its survival, nutrition, health, transportation, agriculture, and the functioning of processes. Chemical-based products have to be designed/developed in order to meet these needs, while at the same time, they must be innovative and sustainable...... to these two topics are given. In addition, a generic computer-aided framework for the design of molecules, mixtures, and blends is presented. The application of the framework is highlighted for molecular products through two case studies involving the design of refrigerants and surfactants....

  11. Energy-aware memory management for embedded multimedia systems a computer-aided design approach

    CERN Document Server

    Balasa, Florin

    2011-01-01

    Energy-Aware Memory Management for Embedded Multimedia Systems: A Computer-Aided Design Approach presents recent computer-aided design (CAD) ideas that address memory management tasks, particularly the optimization of energy consumption in the memory subsystem. It explains how to efficiently implement CAD solutions, including theoretical methods and novel algorithms. The book covers various energy-aware design techniques, including data-dependence analysis techniques, memory size estimation methods, extensions of mapping approaches, and memory banking approaches. It shows how these techniques

  12. A Computer-Aided Diagnosis System for Breast Cancer Combining Digital Mammography and Genomics

    Science.gov (United States)

    2006-05-01

    Huang, "Breast cancer diagnosis using self-organizing map for sonography." Ultrasound Med. Biol. 26, 405 (2000). 20 K. Horsch, M.L. Giger, L.A. Venta ...L.A. Venta , "Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography." Acad Radiol 11, 272 (2004). 22 W. Chen...418. 27. Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography

  13. An overview of interactive computer graphics and its application to computer-aided engineering and design

    International Nuclear Information System (INIS)

    Van Dam, A.

    1983-01-01

    The purpose of this brief birds-eye view of interactive graphics is to list the key ideas, and to show how one of the most important application areas, Computer Aided Engineering/Design takes advantage of it. (orig.)

  14. Deep learning for cardiac computer-aided diagnosis: benefits, issues & solutions.

    Science.gov (United States)

    Loh, Brian C S; Then, Patrick H H

    2017-01-01

    Cardiovascular diseases are one of the top causes of deaths worldwide. In developing nations and rural areas, difficulties with diagnosis and treatment are made worse due to the deficiency of healthcare facilities. A viable solution to this issue is telemedicine, which involves delivering health care and sharing medical knowledge at a distance. Additionally, mHealth, the utilization of mobile devices for medical care, has also proven to be a feasible choice. The integration of telemedicine, mHealth and computer-aided diagnosis systems with the fields of machine and deep learning has enabled the creation of effective services that are adaptable to a multitude of scenarios. The objective of this review is to provide an overview of heart disease diagnosis and management, especially within the context of rural healthcare, as well as discuss the benefits, issues and solutions of implementing deep learning algorithms to improve the efficacy of relevant medical applications.

  15. Computer-aided diagnosis in routine mammography

    International Nuclear Information System (INIS)

    Sittek, H.; Perlet, C.; Helmberger, R.; Linsmeier, E.; Kessler, M.; Reiser, M.

    1998-01-01

    Purpose: Computer-aided diagnosis in mammography is a topic many study groups have been concerned with since the first presentation of a system for computer-aided interpretation in 1967. Currently, there is only one system avilable for clinical use in mammography, the CAD-System Image Checker (R2 Technology). The purpose of our prospective study was to evaluate whether the integration of the CAD-system into the routine of a radiological breast diagnosis unit is feasible. Results: After the installation of the CAD-system, 300 patients with 1110 mammograms were included for evaluation in the present study. In 54 of these cases histological examination was indicated due to suspect criteria on conventional mammography. In 39 of 54 cases (72,2%) malignancy could be proven histologically. The CAD-system marked 82,1% of the histologically verified carcinomas correctly 94,3% of all 1797 marks made by the CAD-system indicated normal or benign structures. Routinely performed CAD analysis prolonged patients waiting time by about 15 min because the marks of the CAD system had to be interpreted in addition to the routine diagnostic investigations. Conclusion: Our experience with the use of the CAD-system in daily routine showed that CAD analysis can easily be integrated into a preexisting mammography unit. However, the diagnostic benefit is not yet clearly established. Since the rate of false negative marks by the CAD-system Image Checker is still high, the results of CAD analysis must be checked and corrected by an observer well experienced in mammography reading. (orig.) [de

  16. Development of a Computer-Aided System for Competitive Intelligence%竞争情报计算机辅助系统的开发

    Institute of Scientific and Technical Information of China (English)

    刘玉照; 曹君祥

    2000-01-01

    Competitive Information System (CIS) is a computer-aided system for competitive intelligence, and is designed for the information requirements of the corporate strategic management. The development of CIS is an important part of corporate Strategic Information Planning (SIP), and CIS directly supports the strategic objects of the corporate. The life cycle of CIS includes traditional life cycle, prototyping life cycle, object-oriented life cycle and so on.

  17. Computer-aided drug design at Boehringer Ingelheim

    Science.gov (United States)

    Muegge, Ingo; Bergner, Andreas; Kriegl, Jan M.

    2017-03-01

    Computer-Aided Drug Design (CADD) is an integral part of the drug discovery endeavor at Boehringer Ingelheim (BI). CADD contributes to the evaluation of new therapeutic concepts, identifies small molecule starting points for drug discovery, and develops strategies for optimizing hit and lead compounds. The CADD scientists at BI benefit from the global use and development of both software platforms and computational services. A number of computational techniques developed in-house have significantly changed the way early drug discovery is carried out at BI. In particular, virtual screening in vast chemical spaces, which can be accessed by combinatorial chemistry, has added a new option for the identification of hits in many projects. Recently, a new framework has been implemented allowing fast, interactive predictions of relevant on and off target endpoints and other optimization parameters. In addition to the introduction of this new framework at BI, CADD has been focusing on the enablement of medicinal chemists to independently perform an increasing amount of molecular modeling and design work. This is made possible through the deployment of MOE as a global modeling platform, allowing computational and medicinal chemists to freely share ideas and modeling results. Furthermore, a central communication layer called the computational chemistry framework provides broad access to predictive models and other computational services.

  18. Computer-aided discovery of antimicrobial agents as potential enoyl ...

    African Journals Online (AJOL)

    Computer-aided discovery of antimicrobial agents as potential enoyl acyl carrier protein reductase inhibitors. ... Conclusion: Overall, the newly discovered hits can act as a good starting point in the future for the development of safe and potent antibacterial agents. Keywords: Enoyl acyl carrier protein reductase, saFabI, ...

  19. Computer-Aided Chemical Product Design Framework: Design of High Performance and Environmentally Friendly Refrigerants

    DEFF Research Database (Denmark)

    Cignitti, Stefano; Zhang, Lei; Gani, Rafiqul

    properties and needs should carefully be selected for a given heat pump cycle to ensure that an optimum refrigerant is found? How can cycle performance and environmental criteria be integrated at the product design stage and not in post-design analysis? Computer-aided product design methods enable...... the possibility of designing novel molecules, mixtures and blends, such as refrigerants through a systematic framework (Cignitti et al., 2015; Yunus et al., 2014). In this presentation a computer-aided framework is presented for chemical product design through mathematical optimization. Here, molecules, mixtures...... and blends, are systematically designed through a decomposition based solution method. Given a problem definition, computer-aided molecular design (CAMD) problem is defined, which is formulated into a mixed integer nonlinear program (MINLP). The decomposed solution method then sequentially divides the MINLP...

  20. Vascular patterns in nodules of intraductal papillary mucinous neoplasms depicted under contrast-enhanced ultrasonography are helpful for evaluating malignant potential

    International Nuclear Information System (INIS)

    Kurihara, Naoko; Kawamoto, Hirofumi; Kobayashi, Yoshiyuki; Okamoto, Yuko; Yamamoto, Naoki; Tsutsumi, Koichiro; Fujii, Masakuni; Kato, Hironari; Yamamoto, Kazuhide

    2012-01-01

    Objectives: The purpose of this study is to evaluate the feasibility of contrast-enhanced ultrasonography (CE-US) to differentiate between benign and malignant intraductal papillary mucinous neoplasms (IPMN). Patients and methods: Contrast-enhanced ultrasonography with a contrast agent was performed on 22 consecutive patients with IPMN suspected of being malignant. This revealed 10 carcinomas, 1 borderline lesion and 11 adenomas. All patients underwent surgery, and the histological diagnosis was confirmed by examination of resected specimens. CE-US was performed using a contrast agent. The detection rates of mural nodules were compared between CE-US and contrast-enhanced computed tomography (CE-CT), and the imaging of mural nodules depicted under CE-US was analyzed. Results: Seventeen of 22 resected specimens (77.3%) had mural nodules. There was no significant difference in the detection rate between CE-US (n = 15; 88.2%) and CE-CT (n = 12; 70.6%). In 12 (80.0%) of these patients, CE-US revealed small vessels in the mural nodule. The spotty or linear-shaped pattern was detected in 4 patients and the branch-shaped pattern in 8. The branch-shaped pattern lesion was associated with carcinoma. These mural nodules were 10 mm or more in height. In the perfusion image phase, cystic walls and mural nodules were also enhanced in all cases. Conclusion: The vessel shapes of the mural nodules depicted under CE-US were associated with size and pathological findings. These results suggested that CE-US with a contrast agent is a powerful modality with which to evaluate the malignant potential of IPMN.

  1. A Multi-step and Multi-level approach for Computer Aided Molecular Design

    DEFF Research Database (Denmark)

    . The problem formulation step incorporates a knowledge base for the identification and setup of the design criteria. Candidate compounds are identified using a multi-level generate and test CAMD solution algorithm capable of designing molecules having a high level of molecular detail. A post solution step...... using an Integrated Computer Aided System (ICAS) for result analysis and verification is included in the methodology. Keywords: CAMD, separation processes, knowledge base, molecular design, solvent selection, substitution, group contribution, property prediction, ICAS Introduction The use of Computer...... Aided Molecular Design (CAMD) for the identification of compounds having specific physic...

  2. The effects of computer-aided design software on engineering students' spatial visualisation skills

    Science.gov (United States)

    Kösa, Temel; Karakuş, Fatih

    2018-03-01

    The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations (PSVT:R) for both the pre- and the post-test. The participants were 116 freshman students in the first year of their undergraduate programme in the Department of Mechanical Engineering at a university in Turkey. A total of 72 students comprised the experimental group; they were instructed with CAD-based activities in an engineering drawing course. The control group consisted of 44 students who did not attend this course. The results of the study showed that a CAD-based engineering drawing course had a positive effect on developing engineering students' spatial visualisation skills. Additionally, the results of the study showed that spatial visualisation skills can be a predictor for success in a computer-aided engineering drawing course.

  3. [Computer aided design for fixed partial denture framework based on reverse engineering technology].

    Science.gov (United States)

    Sun, Yu-chun; Lü, Pei-jun; Wang, Yong

    2006-03-01

    To explore a computer aided design (CAD) route for the framework of domestic fixed partial denture (FPD) and confirm the suitable method of 3-D CAD. The working area of a dentition model was scanned with a 3-D mechanical scanner. Using the reverse engineering (RE) software, margin and border curves were extracted and several reference curves were created to ensure the dimension and location of pontic framework that was taken from the standard database. The shoulder parts of the retainers were created after axial surfaces constructed. The connecting areas, axial line and curving surface of the framework connector were finally created. The framework of a three-unit FPD was designed with RE technology, which showed smooth surfaces and continuous contours. The design route is practical. The result of this study is significant in theory and practice, which will provide a reference for establishing the computer aided design/computer aided manufacture (CAD/CAM) system of domestic FPD.

  4. SAMO [Sistema de Apoyo Mechanizado a la Operacion]: An operational aids computer system

    International Nuclear Information System (INIS)

    Stormer, T.D.; Laflor, E.V.

    1989-01-01

    SAMO (Sistema de Apoyo Mechanizado a la Operacion) is a sensor-driven, computer-based, graphic display system designed by Westinghouse to aid the A. N. Asco operations staff during all modes of plant operations, including emergencies. The SAMO system is being implemented in the A. N. Asco plant in two phases that coincide with consecutive refueling outages for each of two nuclear units at the Asco site. Phase 1 of the SAMO system implements the following functions: (1) emergency operational aids, (2) postaccident monitoring, (3) plant graphics display, (4) high-speed transient analysis recording, (5) historical data collection, storage, and retrieval, (6) sequence of events, and (7) posttrip review. During phase 2 of the SAMO project, the current plant computer will be removed and the functions now performed by the plant computer will be performed by the SAMO system. In addition, the following functions will be implemented: (1) normal and simple transients operational aid, (2) plant information graphics; and (3) real-time radiological off-site dose calculation

  5. [Accuracy of computer aided measurement for detecting dental proximal caries lesions in images of cone-beam computed tomography].

    Science.gov (United States)

    Zhang, Z L; Li, J P; Li, G; Ma, X C

    2017-02-09

    Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the

  6. Computer-aided reduction of plasma data

    International Nuclear Information System (INIS)

    Shariati, S.

    1984-01-01

    Poor signal-to-noise ratios and the non-linear characteristics of the data obtained by most plasma diagnostic equipment makes computer-aided data handling a desirable feature in plasma laboratories. The Lecroy 3500-SA32 signal analyzer is used as the data handling system in this work. The performance of the Lecroy 3500-SA32 signal analyzer, used for recording and reducing the plasma data under the noisy environment of the laboratory, is reported. The data characteristics and software programs are discussed for three types of plasma diagnostic equipment: 1) Langmuir Probes; 2) Charge Exchange Neutral Energy Analyzers; 3) Retarding Potential Energy Analyzers. In order to protect the computer internal circuitry and to have satisfactory data acquisition and handling, methods for dealing with the noisy environment, including stray magnetic fields, RF radiation, and transient spikes on power lines, are also developed. Three computer programs are included which obtain an iterated best fit of experimental data to the corresponding analytical expressions for each case. The new data handling system enables the user to do a real-time analysis of data by using the interactive features of the Lecroy 3500-SA32 system

  7. Diagnosis by computer-aided tomography in patients with carcinomas in the rectum-sigma area

    International Nuclear Information System (INIS)

    Gnann, H.; Huebener, K.H.; Ahlemann, L.M.; Harms, S.

    1984-01-01

    In a retrospective study on the patients at Tuebingen between 1977 and 1980, the diagnostic value of computer-aided tomography was investigated in 232 cases of carcinomas in the rectum-sigma area. 192 examinations were post-operative. Whether computer-aided tomography will catch on as a staging measure in the pre-operative phase must for now remain unanswered until prospective studies on a large number of patients have been carried through. However, it is useful as a decision-taking aid as regards the choice of the operation method and to clarify whether the carcinoma is operable. Far more important in view of the known high rate of recurvency and metastatic spread seems to be the role of computer-aided tomography in the aftercare especially of those patients who had their rectum removed: the diagnosis of the recidivation permits direct therapeutic action (a second operation, radiation therapy) at an early date. The search for clinically not previously known recidivations revealed that computer-aided tomography had in 124 patients with operated rectal carcinoma a high sensitivity of 98 per cent, a specificity of 87 per cent and an accuracy of 91.9 percent. How long after the operation CAT checks should be carried through is quite as uncertain at present as the role of CAT in the staging of those tumors. The authors recommend intervals of 2-3 months within the first two post-operative years. (orig.) [de

  8. The computer aided education and training system for accident management

    International Nuclear Information System (INIS)

    Yoneyama, Mitsuru; Kubota, Ryuji; Fujiwara, Tadashi; Sakuma, Hitoshi

    1999-01-01

    The education and training system for Accident Management was developed by the Japanese BWR group and Hitachi Ltd. The education and training system is composed of two systems. One is computer aided instruction (CAI) education system and the education and training system with computer simulations. Both systems are designed to be executed on personal computers. The outlines of the CAI education system and the education and training system with simulator are reported below. These systems provides plant operators and technical support center staff with the effective education and training for accident management. (author)

  9. CONTRIBUTIONS FOR DEVELOPING OF A COMPUTER AIDED LEARNING ENVIRONMENT OF DESCRIPTIVE GEOMETRY

    Directory of Open Access Journals (Sweden)

    Antonescu Ion

    2009-07-01

    Full Text Available The paper presents the authors’ contributions for developing a computer code for teaching of descriptive geometry using the computer aided learning techniques. The program was implemented using the programming interface and the 3D modeling capabilities of the AutoCAD system.

  10. New design methods for computer aided architecturald design methodology teaching

    NARCIS (Netherlands)

    Achten, H.H.

    2003-01-01

    Architects and architectural students are exploring new ways of design using Computer Aided Architectural Design software. This exploration is seldom backed up from a design methodological viewpoint. In this paper, a design methodological framework for reflection on innovate design processes by

  11. USE OF COMPUTER-AIDED PROCESS ENGINEERING TOOL IN POLLUTION PREVENTION

    Science.gov (United States)

    Computer-Aided Process Engineering has become established in industry as a design tool. With the establishment of the CAPE-OPEN software specifications for process simulation environments. CAPE-OPEN provides a set of "middleware" standards that enable software developers to acces...

  12. Computer-Aided Model Based Analysis for Design and Operation of a Copolymerization Process

    DEFF Research Database (Denmark)

    Lopez-Arenas, Maria Teresa; Sales-Cruz, Alfonso Mauricio; Gani, Rafiqul

    2006-01-01

    . This will allow analysis of the process behaviour, contribute to a better understanding of the polymerization process, help to avoid unsafe conditions of operation, and to develop operational and optimizing control strategies. In this work, through a computer-aided modeling system ICAS-MoT, two first......The advances in computer science and computational algorithms for process modelling, process simulation, numerical methods and design/synthesis algorithms, makes it advantageous and helpful to employ computer-aided modelling systems and tools for integrated process analysis. This is illustrated......-principles models have been investigated with respect to design and operational issues for solution copolymerization reactors in general, and for the methyl methacrylate/vinyl acetate system in particular. The Model 1 is taken from literature and is commonly used for low conversion region, while the Model 2 has...

  13. PACS-Based Computer-Aided Detection and Diagnosis

    Science.gov (United States)

    Huang, H. K. (Bernie); Liu, Brent J.; Le, Anh HongTu; Documet, Jorge

    The ultimate goal of Picture Archiving and Communication System (PACS)-based Computer-Aided Detection and Diagnosis (CAD) is to integrate CAD results into daily clinical practice so that it becomes a second reader to aid the radiologist's diagnosis. Integration of CAD and Hospital Information System (HIS), Radiology Information System (RIS) or PACS requires certain basic ingredients from Health Level 7 (HL7) standard for textual data, Digital Imaging and Communications in Medicine (DICOM) standard for images, and Integrating the Healthcare Enterprise (IHE) workflow profiles in order to comply with the Health Insurance Portability and Accountability Act (HIPAA) requirements to be a healthcare information system. Among the DICOM standards and IHE workflow profiles, DICOM Structured Reporting (DICOM-SR); and IHE Key Image Note (KIN), Simple Image and Numeric Report (SINR) and Post-processing Work Flow (PWF) are utilized in CAD-HIS/RIS/PACS integration. These topics with examples are presented in this chapter.

  14. Computer Aided Design and Analysis of Separation Processes with Electrolyte Systems

    DEFF Research Database (Denmark)

    A methodology for computer aided design and analysis of separation processes involving electrolyte systems is presented. The methodology consists of three main parts. The thermodynamic part "creates" the problem specific property model package, which is a collection of pure component and mixture...... property models. The design and analysis part generates process (flowsheet) alternatives, evaluates/analyses feasibility of separation and provides a visual operation path for the desired separation. The simulation part consists of a simulation/calculation engine that allows the screening and validation...... of process alternatives. For the simulation part, a general multi-purpose, multi-phase separation model has been developed and integrated to an existing computer aided system. Application of the design and analysis methodology is highlighted through two illustrative case studies....

  15. Computer Aided Design and Analysis of Separation Processes with Electrolyte Systems

    DEFF Research Database (Denmark)

    Takano, Kiyoteru; Gani, Rafiqul; Kolar, P.

    2000-01-01

    A methodology for computer aided design and analysis of separation processes involving electrolyte systems is presented. The methodology consists of three main parts. The thermodynamic part 'creates' the problem specific property model package, which is a collection of pure component and mixture...... property models. The design and analysis part generates process (flowsheet) alternatives, evaluates/analyses feasibility of separation and provides a visual operation path for the desired separation. The simulation part consists of a simulation/calculation engine that allows the screening and validation...... of process alternatives. For the simulation part, a general multi-purpose, multi-phase separation model has been developed and integrated to an existing computer aided system. Application of the design and analysis methodology is highlighted through two illustrative case studies, (C) 2000 Elsevier Science...

  16. Computer-aided design of the RF-cavity for a high-power S-band klystron

    Science.gov (United States)

    Kant, D.; Bandyopadhyay, A. K.; Pal, D.; Meena, R.; Nangru, S. C.; Joshi, L. M.

    2012-08-01

    This article describes the computer-aided design of the RF-cavity for a S-band klystron operating at 2856 MHz. State-of-the-art electromagnetic simulation tools SUPERFISH, CST Microwave studio, HFSS and MAGIC have been used for cavity design. After finalising the geometrical details of the cavity through simulation, it has been fabricated and characterised through cold testing. Detailed results of the computer-aided simulation and cold measurements are presented in this article.

  17. Computer-Aided Numerical Inversion of Laplace Transform

    Directory of Open Access Journals (Sweden)

    Umesh Kumar

    2000-01-01

    Full Text Available This paper explores the technique for the computer aided numerical inversion of Laplace transform. The inversion technique is based on the properties of a family of three parameter exponential probability density functions. The only limitation in the technique is the word length of the computer being used. The Laplace transform has been used extensively in the frequency domain solution of linear, lumped time invariant networks but its application to the time domain has been limited, mainly because of the difficulty in finding the necessary poles and residues. The numerical inversion technique mentioned above does away with the poles and residues but uses precomputed numbers to find the time response. This technique is applicable to the solution of partially differentiable equations and certain classes of linear systems with time varying components.

  18. Computer-aided method for recognition of proton track in nuclear emulsion

    International Nuclear Information System (INIS)

    Ruan Jinlu; Li Hongyun; Song Jiwen; Zhang Jianfu; Chen Liang; Zhang Zhongbing; Liu Jinliang

    2014-01-01

    In order to overcome the shortcomings of the manual method for proton-recoil track recognition in nuclear emulsions, a computer-aided track recognition method was studied. In this method, image sequences captured by a microscope system were processed through image convolution with composite filters, binarization by multi thresholds, track grains clustering and redundant grains removing to recognize the track grains in the image sequences. Then the proton-recoil tracks were reconstructed from the recognized track grains through track reconstruction. The proton-recoil tracks in the nuclear emulsion irradiated by the neutron beam at energy of 14.9 MeV were recognized by the computer-aided method. The results show that proton-recoil tracks reconstructed by this method consist well with those reconstructed by the manual method. This compute-raided track recognition method lays an important technical foundation of developments of a proton-recoil track automatic recognition system and applications of nuclear emulsions in pulsed neutron spectrum measurement. (authors)

  19. Computer-aided modelling template: Concept and application

    DEFF Research Database (Denmark)

    Fedorova, Marina; Sin, Gürkan; Gani, Rafiqul

    2015-01-01

    decomposition technique which identifies generic steps and workflow involved, the computer-aided template concept has been developed. This concept is implemented as a software tool, which provides a user-friendly interface for following the workflow steps and guidance through the steps providing additional......Modelling is an important enabling technology in modern chemical engineering applications. A template-based approach is presented in this work to facilitate the construction and documentation of the models and enable their maintenance for reuse in a wider application range. Based on a model...

  20. Computer Aided Methodology for Simultaneous Synthesis, Design & Analysis of Chemical Products-Processes

    DEFF Research Database (Denmark)

    d'Anterroches, Loïc; Gani, Rafiqul

    2006-01-01

    A new combined methodology for computer aided molecular design and process flowsheet design is presented. The methodology is based on the group contribution approach for prediction of molecular properties and design of molecules. Using the same principles, process groups have been developed...... a wide range of problems. In this paper, only the computer aided flowsheet design related features are presented....... together with their corresponding flowsheet property models. To represent the process flowsheets in the same way as molecules, a unique but simple notation system has been developed. The methodology has been converted into a prototype software, which has been tested with several case studies covering...

  1. HINT for Squint: A Computer Reliant Diagnostic Aid for Strabismus

    OpenAIRE

    Gieszl, Louis R.; Morris, Jacqueline; Guyton, David L.

    1983-01-01

    This paper provides an outline of methods used for the implementation of a computer reliant diagnostic aid in the medical specialty of Ophthalmology. Some problems have been associated with many previous diagnostic models. A careful review indicates that the most serious problems were:

  2. Computer-Aided Test Flow in Core-Based Design

    OpenAIRE

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the test-pattern generation and fault coverage determination in the core based design. The basic core-test strategy that one has to apply in the core-based design is stated in this work. A Computer-Aided Test (CAT) flow is proposed resulting in accurate fault coverage of embedded cores. The CAT now is applied to a few cores within the Philips Core Test Pilot IC project

  3. An Integrated Computer-Aided Approach for Environmental Studies

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Chen, Fei; Jaksland, Cecilia

    1997-01-01

    A general framework for an integrated computer-aided approach to solve process design, control, and environmental problems simultaneously is presented. Physicochemical properties and their relationships to the molecular structure play an important role in the proposed integrated approach. The sco...... and applicability of the integrated approach is highlighted through examples involving estimation of properties and environmental pollution prevention. The importance of mixture effects on some environmentally important properties is also demonstrated....

  4. Computer-aided auscultation learning system for nursing technique instruction.

    Science.gov (United States)

    Hou, Chun-Ju; Chen, Yen-Ting; Hu, Ling-Chen; Chuang, Chih-Chieh; Chiu, Yu-Hsien; Tsai, Ming-Shih

    2008-01-01

    Pulmonary auscultation is a physical assessment skill learned by nursing students for examining the respiratory system. Generally, a sound simulator equipped mannequin is used to group teach auscultation techniques via classroom demonstration. However, nursing students cannot readily duplicate this learning environment for self-study. The advancement of electronic and digital signal processing technologies facilitates simulating this learning environment. This study aims to develop a computer-aided auscultation learning system for assisting teachers and nursing students in auscultation teaching and learning. This system provides teachers with signal recording and processing of lung sounds and immediate playback of lung sounds for students. A graphical user interface allows teachers to control the measuring device, draw lung sound waveforms, highlight lung sound segments of interest, and include descriptive text. Effects on learning lung sound auscultation were evaluated for verifying the feasibility of the system. Fifteen nursing students voluntarily participated in the repeated experiment. The results of a paired t test showed that auscultative abilities of the students were significantly improved by using the computer-aided auscultation learning system.

  5. Computer-aided navigation in dental implantology: 7 years of clinical experience.

    Science.gov (United States)

    Ewers, Rolf; Schicho, Kurt; Truppe, Michael; Seemann, Rudolf; Reichwein, Astrid; Figl, Michael; Wagner, Arne

    2004-03-01

    This long-term study gives a review over 7 years of research, development, and routine clinical application of computer-aided navigation technology in dental implantology. Benefits and disadvantages of up-to-date technologies are discussed. In the course of the current advancement, various hardware and software configurations are used. In the initial phase, universally applicable navigation software is adapted for implantology. Since 2001, a special software module for dental implantology is available. Preoperative planning is performed on the basis of prosthetic aspects and requirements. In clinical routine use, patient and drill positions are intraoperatively registered by means of optoelectronic tracking systems; during preclinical tests, electromagnetic trackers are also used. In 7 years (1995 to 2002), 55 patients with 327 dental implants were successfully positioned with computer-aided navigation technology. The mean number of implants per patient was 6 (minimum, 1; maximum, 11). No complications were observed; the preoperative planning could be exactly realized. The average expenditure of time for the preparation of a surgical intervention with navigation decreased from 2 to 3 days in the initial phase to one-half day in clinical routine use with software that is optimized for dental implantology. The use of computer-aided navigation technology can contribute to considerable quality improvement. Preoperative planning is exactly realized and intraoperative safety is increased, because damage to nerves or neighboring teeth can be avoided.

  6. Abdominal Computed tomography of 25 patients with AIDS or lymphadenopathy Syndrome

    International Nuclear Information System (INIS)

    Arrive, L.; Frija, J.; Couderc, L.J.; Clauvel, J.P.; Laval-Jeantet, M.; Matheron, S.

    1986-01-01

    An abdominal computed tomographic examination was performed to 20 patients with Acquired Immunodeficiency Syndrome (AIDS) and to 5 patients with Lymphadenopathy Syndrome (LAS). Intraabdominal lymph nodes were seen in 18 out of 20 cases of AIDS and in 5 cases of LAS. Lymph nodes have a normal size or are slightly enlarged but they are too numerous. Splenomegaly was found in 17 patients. Rectal modifications secondary to a proctitis were seen in the homosexual patients [fr

  7. A multicenter study on objective and subjective benefits with a transcutaneous bone-anchored hearing aid device

    DEFF Research Database (Denmark)

    Hougaard, Dan Dupont; Boldsen, Soren Kjaergaard; Jensen, Anne Marie

    2017-01-01

    Examination of objective as well as subjective outcomes with a new transcutaneous bone-anchored hearing aid device. The study was designed as a prospective multicenter consecutive case-series study involving tertiary referral centers at two Danish University Hospitals. A total of 23 patients were...... implanted. Three were lost to follow-up. Patients had single-sided deafness, conductive or mixed hearing loss. Intervention: Rehabilitative. Aided and unaided sound field hearing was evaluated objectively using (1) pure warble tone thresholds, (2) pure-tone average (PTA4), (3) speech discrimination score...... (SDS) in quiet, and (4) speech reception threshold 50% at 70 dB SPL noise level (SRT50%). Subjective benefit was evaluated by three validated questionnaires: (1) the IOI-HA, (2) the SSQ-12, and (3) a questionnaire evaluating both the frequency and the duration of hearing aid usage. The mean aided PTA4...

  8. Analysis of three-phase power-supply systems using computer-aided design programs

    International Nuclear Information System (INIS)

    Oberst, E.F.

    1977-01-01

    A major concern of every designer of large, three-phase power-supply systems is the protection of system components from overvoltage transients. At present, three computer-aided circuit design programs are available in the Magnetic Fusion Energy (MFE) National Computer Center that can be used to analyze three-phase power systems: MINI SCEPTRE, SPICE I, and SPICE II. These programs have been used at Lawrence Livermore Laboratory (LLL) to analyze the operation of a 200-kV dc, 20-A acceleration power supply for the High Voltage Test Stand. Various overvoltage conditions are simulated and the effectiveness of system protective devices is observed. The simulated overvoltage conditions include such things as circuit breaker openings, pulsed loading, and commutation voltage surges in the rectifiers. These examples are used to illustrate the use of the computer-aided, circuit-design programs discussed in this paper

  9. Computer Aided Education System SuperTest. Present and Prospective

    Directory of Open Access Journals (Sweden)

    2007-01-01

    Full Text Available This paper analyzes the testing and self-testing process for the Computer Aided Education System (CAES SuperTest, used at the Academy of Economic Studies of Chisinau, Moldova and recently implemented at the University of Bacau, Romania. We discuss here the future of this software, from the Information Society and Knowledge Society point of view.

  10. A Novel Computer-Aided Design/Computer-Assisted Manufacture Method for One-Piece Removable Partial Denture and Evaluation of Fit.

    Science.gov (United States)

    Ye, Hongqiang; Li, Xinxin; Wang, Guanbo; Kang, Jing; Liu, Yushu; Sun, Yuchun; Zhou, Yongsheng

    2018-02-15

    To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro. A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs. Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs. One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.

  11. Evaluation of computer aided volumetry for simulated small pulmonary nodules on computed tomography

    International Nuclear Information System (INIS)

    Do, Kyung Hyun; Goo, Jin Mo; Lee, Kyung Won; Im, Jung Gi; Chung, Myung Jin

    2004-01-01

    To determine the accuracy of automated computer aided volumetry for simulated small pulmonary nodules at computed tomography using various types of phantoms Three sets of synthetic nodules (small, calcified and those adjacent to vessels) were studied. The volume of the nodules in each set was already known, and using multi-slice CT, volumetric data for each nodule was acquired from the three-dimensional reconstructed image. The volume was calculated by applying three different threshold values using Rapidia software (3D-Med, Seoul, Korea). Relative errors in the measured volume of synthetic pulmonary nodules were 17.3, 2.9, and 11.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=0.96, p<0.001). For calcified nodules, relative errors in measured volume were 10.9, 5.3, and 16.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=1.03, p<0.001). In cases involving synthetic nodules adjacent to vessels, relative errors were 4.6, 16.3, and 31.2% at -200, -400, and -600 HU, respectively. There was good correlation between true volume and measured volume at -200 HU (r=1.1, p<0.001). Using computer-aided volumetry, the measured volumes of synthetic nodules correlated closely with their true volume. Measured volumes were the same at each threshold level, regardless of window setting

  12. Evaluation of computer aided volumetry for simulated small pulmonary nodules on computed tomography

    International Nuclear Information System (INIS)

    Goo, Jin Mo; Lee, Kyung Won; Im, Jung Gi; Do, Kyung Hyun; Chung, Myung Jin

    2004-01-01

    To determine the accuracy of automated computer aided volumetry for simulated small pulmonary nodules at computed tomography using various types of phantoms. Three sets of synthetic nodules (small, calcified and those adjacent to vessels) were studied. The volume of the nodules in each set was already known, and using multi-slice CT, volumetric data for each nodule was acquired from the three-dimensional reconstructed image. The volume was calculated by applying three different threshold values using Rapidia software (3D-Med, Seoul, Korea). Relative errors in the measured volume of synthetic pulmonary nodules were 17.3, 2.9, and 11.5% at -200, -400, and --600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=0.96, p<0.001). For calcified nodules, relative errors in measured volume were 10.9, 5.3, and 16.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=1.03, p<0.001). In cases involving synthetic nodules adjacent to vessels, relative errors were 4.6, 16.3, and 31.2 % at -200, -400, and -600 HU, respectively. There was good correlation between true volume and measured volume at -200 HU (r=1.1, p<0.001). Using computer-aided volumetry, the measured volumes of synthetic nodules correlated closely with their true volume. Measured volumes were the same at each threshold level, regardless of window setting

  13. Computer aided systems human engineering: A hypermedia tool

    Science.gov (United States)

    Boff, Kenneth R.; Monk, Donald L.; Cody, William J.

    1992-01-01

    The Computer Aided Systems Human Engineering (CASHE) system, Version 1.0, is a multimedia ergonomics database on CD-ROM for the Apple Macintosh II computer, being developed for use by human system designers, educators, and researchers. It will initially be available on CD-ROM and will allow users to access ergonomics data and models stored electronically as text, graphics, and audio. The CASHE CD-ROM, Version 1.0 will contain the Boff and Lincoln (1988) Engineering Data Compendium, MIL-STD-1472D and a unique, interactive simulation capability, the Perception and Performance Prototyper. Its features also include a specialized data retrieval, scaling, and analysis capability and the state of the art in information retrieval, browsing, and navigation.

  14. Computer-Aided Grading of Lymphangioleiomyomatosis (LAM) using HRCT

    Science.gov (United States)

    Yao, Jianhua; Avila, Nilo; Dwyer, Andrew; Taveira-DaSilva, Angelo M.; Hathaway, Olanda M.; Moss, Joel

    2010-01-01

    Lymphangioleiomyomatosis (LAM) is a multisystem disorder associated with proliferation of smooth muscle-like cells, which leads to destruction of lung parenchyma. Subjective grading of LAM on HRCT is imprecise and can be arduous especially in cases with severe involvement. We propose a computer-aided evaluation system that grades LAM involvement based on analysis of lung texture patterns. A committee of support vector machines is employed for classification. The system was tested on 36 patients. The computer grade demonstrates good correlation with subjective radiologist grade (R=0.91, p<0.0001) and pulmonary functional tests (R=0.85, p<0.0001). The grade also provides precise progression assessment of disease over time. PMID:21625320

  15. Present state of computer-aided diagnosis (CAD) development

    International Nuclear Information System (INIS)

    Fujita, Hiroshi

    2007-01-01

    Topics of computer-aided detection (CAD) are reviewed. Commercially available, Food and Drug Administration (FDA)-approved CAD systems are for fields of breast cancer (mammography), chest (flat X-ray and CT imaging) and colon (polyp detection). In Japan, only mammography CAD is approved. Efficacy of CAD is controversial, for which reliable database is important, and its construction is under development in various medical fields. Digitalized image is now popularized, which conceivably leads to improve the cost-effectiveness of diagnosis with CAD. For incentive, approval for health insurance would be the case as seen in the increased CAD sale by R2 Technology Co., and MHLW actually assists facilities to introduce the reading-aid system of mammography by sharing a half of its cost. There are 2 big projects for CAD study supported by MECSST, which the author concerns. One is the development of diagnostic aid for the multi-dimensional medical images where the multi-organ, multi-disease CAD system is considered. The other involves the CAD in brain MRI, in breast US and in eyeground picture. It is not in so far future for patients and doctors to fully enjoy the benefit of CAD. (R.T.)

  16. A computer-aided continuous assessment system

    Directory of Open Access Journals (Sweden)

    B. C.H. Turton

    1996-12-01

    Full Text Available Universities within the United Kingdom have had to cope with a massive expansion in undergraduate student numbers over the last five years (Committee of Scottish University Principals, 1993; CVCP Briefing Note, 1994. In addition, there has been a move towards modularization and a closer monitoring of a student's progress throughout the year. Since the price/performance ratio of computer systems has continued to improve, Computer- Assisted Learning (CAL has become an attractive option. (Fry, 1990; Benford et al, 1994; Laurillard et al, 1994. To this end, the Universities Funding Council (UFQ has funded the Teaching and Learning Technology Programme (TLTP. However universities also have a duty to assess as well as to teach. This paper describes a Computer-Aided Assessment (CAA system capable of assisting in grading students and providing feedback. In this particular case, a continuously assessed course (Low-Level Languages of over 100 students is considered. Typically, three man-days are required to mark one assessed piece of coursework from the students in this class. Any feedback on how the questions were dealt with by the student are of necessity brief. Most of the feedback is provided in a tutorial session that covers the pitfalls encountered by the majority of the students.

  17. CADRIGS--computer aided design reliability interactive graphics system

    International Nuclear Information System (INIS)

    Kwik, R.J.; Polizzi, L.M.; Sticco, S.; Gerrard, P.B.; Yeater, M.L.; Hockenbury, R.W.; Phillips, M.A.

    1982-01-01

    An integrated reliability analysis program combining graphic representation of fault trees, automated data base loadings and reference, and automated construction of reliability code input files was developed. The functional specifications for CADRIGS, the computer aided design reliability interactive graphics system, are presented. Previously developed fault tree segments used in auxiliary feedwater system safety analysis were constructed on CADRIGS and, when combined, yielded results identical to those resulting from manual input to the same reliability codes

  18. Computer-aided Detection of Lung Cancer on Chest Radiographs: Effect on Observer Performance

    NARCIS (Netherlands)

    de Hoop, Bartjan; de Boo, Diederik W.; Gietema, Hester A.; van Hoorn, Frans; Mearadji, Banafsche; Schijf, Laura; van Ginneken, Bram; Prokop, Mathias; Schaefer-Prokop, Cornelia

    2010-01-01

    Purpose: To assess how computer-aided detection (CAD) affects reader performance in detecting early lung cancer on chest radiographs. Materials and Methods: In this ethics committee-approved study, 46 individuals with 49 computed tomographically (CT)-detected and histologically proved lung cancers

  19. National Survey of Computer Aided Manufacturing in Industrial Technology Programs.

    Science.gov (United States)

    Heidari, Farzin

    The current status of computer-aided manufacturing in the 4-year industrial technology programs in the United States was studied. All industrial technology department chairs were mailed a questionnaire divided into program information, equipment information, and general comments sections. The questionnaire was designed to determine the subjects…

  20. Impact of Computer-Aided Warfarin Dosing in a Saudi Arabian ...

    African Journals Online (AJOL)

    Purpose: To compare the efficacy of computer-aided dosing using Coagclinic (a web-based software) with physician dosing in patients receiving warfarin for various cardiac indications. Methods: In order to calculate the effectiveness of physician managed anticoagulation dosing, we calculated the “percentage of time ...

  1. Application of CT-PSF-based computer-simulated lung nodules for evaluating the accuracy of computer-aided volumetry.

    Science.gov (United States)

    Funaki, Ayumu; Ohkubo, Masaki; Wada, Shinichi; Murao, Kohei; Matsumoto, Toru; Niizuma, Shinji

    2012-07-01

    With the wide dissemination of computed tomography (CT) screening for lung cancer, measuring the nodule volume accurately with computer-aided volumetry software is increasingly important. Many studies for determining the accuracy of volumetry software have been performed using a phantom with artificial nodules. These phantom studies are limited, however, in their ability to reproduce the nodules both accurately and in the variety of sizes and densities required. Therefore, we propose a new approach of using computer-simulated nodules based on the point spread function measured in a CT system. The validity of the proposed method was confirmed by the excellent agreement obtained between computer-simulated nodules and phantom nodules regarding the volume measurements. A practical clinical evaluation of the accuracy of volumetry software was achieved by adding simulated nodules onto clinical lung images, including noise and artifacts. The tested volumetry software was revealed to be accurate within an error of 20 % for nodules >5 mm and with the difference between nodule density and background (lung) (CT value) being 400-600 HU. Such a detailed analysis can provide clinically useful information on the use of volumetry software in CT screening for lung cancer. We concluded that the proposed method is effective for evaluating the performance of computer-aided volumetry software.

  2. Imperceptible watermarking for security of fundus images in tele-ophthalmology applications and computer-aided diagnosis of retina diseases.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore

    2017-12-01

    The authentication and integrity verification of medical images is a critical and growing issue for patients in e-health services. Accurate identification of medical images and patient verification is an essential requirement to prevent error in medical diagnosis. The proposed work presents an imperceptible watermarking system to address the security issue of medical fundus images for tele-ophthalmology applications and computer aided automated diagnosis of retinal diseases. In the proposed work, patient identity is embedded in fundus image in singular value decomposition domain with adaptive quantization parameter to maintain perceptual transparency for variety of fundus images like healthy fundus or disease affected image. In the proposed method insertion of watermark in fundus image does not affect the automatic image processing diagnosis of retinal objects & pathologies which ensure uncompromised computer-based diagnosis associated with fundus image. Patient ID is correctly recovered from watermarked fundus image for integrity verification of fundus image at the diagnosis centre. The proposed watermarking system is tested in a comprehensive database of fundus images and results are convincing. results indicate that proposed watermarking method is imperceptible and it does not affect computer vision based automated diagnosis of retinal diseases. Correct recovery of patient ID from watermarked fundus image makes the proposed watermarking system applicable for authentication of fundus images for computer aided diagnosis and Tele-ophthalmology applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Battlefield Object Control via Internet Architecture

    Science.gov (United States)

    2002-01-01

    superiority is the best way to reach the goal of competition superiority. Using information technology (IT) in data processing, including computer hardware... technologies : Global Positioning System (GPS), Geographic Information System (GIS), Battlefield Information Transmission System (BITS), and Intelligent...operational environment. Keywords: C4ISR Systems, Information Superiority, Battlefield Objects, Computer - Aided Prototyping System (CAPS), IP-based

  4. Second Asia-Pacific Conference on the Computer Aided System Engineering

    CERN Document Server

    Chaczko, Zenon; Jacak, Witold; Łuba, Tadeusz; Computational Intelligence and Efficiency in Engineering Systems

    2015-01-01

    This carefully edited and reviewed volume addresses the increasingly popular demand for seeking more clarity in the data that we are immersed in. It offers excellent examples of the intelligent ubiquitous computation, as well as recent advances in systems engineering and informatics. The content represents state-of-the-art foundations for researchers in the domain of modern computation, computer science, system engineering and networking, with many examples that are set in industrial application context. The book includes the carefully selected best contributions to APCASE 2014, the 2nd Asia-Pacific Conference on  Computer Aided System Engineering, held February 10-12, 2014 in South Kuta, Bali, Indonesia. The book consists of four main parts that cover data-oriented engineering science research in a wide range of applications: computational models and knowledge discovery; communications networks and cloud computing; computer-based systems; and data-oriented and software-intensive systems.

  5. Computer-Aided Detection in Breast Magnetic Resonance Imaging: A Review

    NARCIS (Netherlands)

    Dorrius, M. D.; Van Ooijen, P.M.A.

    2008-01-01

    The aim of this study is to give an overview on the accuracy of the discrimination between benign and malignant breast lesions on MRI with and without the use of a computer-aided detection (CAD) system. One investigator selected relevant articles based on title and abstract. Ten articles were

  6. Is Contrast Enhanced Ultrasonography a useful tool in a beginner's hand? How much can a Computer Assisted Diagnosis prototype help in characterizing the malignancy of focal liver lesions?

    Science.gov (United States)

    Moga, Tudor Voicu; Popescu, Alina; Sporea, Ioan; Danila, Mirela; David, Ciprian; Gui, Vasile; Iacob, Nicoleta; Miclaus, Gratian; Sirli, Roxana

    2017-08-23

    Contrast enhanced ultrasound (CEUS) improved the characterization of focal liver lesions (FLLs), but is an operatordependent method. The goal of this paper was to test a computer assisted diagnosis (CAD) prototype and to see its benefit in assisting a beginner in the evaluation of FLLs. Our cohort included 97 good quality CEUS videos[34% hepatocellular carcinomas (HCC), 12.3% hypervascular metastases (HiperM), 11.3% hypovascular metastases (HipoM), 24.7% hemangiomas (HMG), 17.5% focal nodular hyperplasia (FNH)] that were used to develop a CAD prototype based on an algorithm that tested a binary decision based classifier. Two young medical doctors (1 year CEUS experience), two experts and the CAD prototype, reevaluated 50 FLLs CEUS videos (diagnosis of benign vs. malignant) first blinded to clinical data, in order to evaluate the diagnostic gap beginner vs. expert. The CAD classifier managed a 75.2% overall (benign vs. malignant) correct classification rate. The overall classification rates for the evaluators, before and after clinical data were: first beginner-78%; 94%; second beginner-82%; 96%; first expert-94%; 100%; second expert-96%; 98%. For both beginners, the malignant vs. benign diagnosis significantly improved after knowing the clinical data (p=0.005; p=0,008). The expert was better than the beginner (p=0.04) and better than the CAD (p=0.001). CAD in addition to the beginner can reach the expert diagnosis. The most frequent lesions misdiagnosed at CEUS were FNH and HCC. The CAD prototype is a good comparing tool for a beginner operator that can be developed to assist the diagnosis. In order to increase the classification rate, the CAD system for FLL in CEUS must integrate the clinical data.

  7. Research on computer aided testing of pilot response to critical in-flight events

    Science.gov (United States)

    Giffin, W. C.; Rockwell, T. H.; Smith, P. J.

    1984-01-01

    Experiments on pilot decision making are described. The development of models of pilot decision making in critical in flight events (CIFE) are emphasized. The following tests are reported on the development of: (1) a frame system representation describing how pilots use their knowledge in a fault diagnosis task; (2) assessment of script norms, distance measures, and Markov models developed from computer aided testing (CAT) data; and (3) performance ranking of subject data. It is demonstrated that interactive computer aided testing either by touch CRT's or personal computers is a useful research and training device for measuring pilot information management in diagnosing system failures in simulated flight situations. Performance is dictated by knowledge of aircraft sybsystems, initial pilot structuring of the failure symptoms and efficient testing of plausible causal hypotheses.

  8. Computer Aided Automatic Control - CAAC artificial intelligence block

    Energy Technology Data Exchange (ETDEWEB)

    Balate, J.; Chramcov, B.; Princ, M. [Brno Univ. of Technology (Czech Republic). Faculty of Technology in Zlin

    2000-07-01

    The aim of the plan to build up the system CAAC - Computer Aided Automatic Control is to create modular setup of partial computing programs including theory of automatic control, algorithms of programs for processing signals and programs of control algorithms. To approach its informative contents to students and professional public the CAAC system utilizes Internet services http in the form of WWW pages. The CAAC system is being processed at the Institute of Automation and Control Technique of the Faculty of Technology in Zlin of the Brno University of Technology and is determined particularly for pedagogic purposes. Recently also the methods of artificial intelligence have been included to the open CAAC system and that is comprised in this article. (orig.)

  9. Method for Statically Checking an Object-oriented Computer Program Module

    Science.gov (United States)

    Bierhoff, Kevin M. (Inventor); Aldrich, Jonathan (Inventor)

    2012-01-01

    A method for statically checking an object-oriented computer program module includes the step of identifying objects within a computer program module, at least one of the objects having a plurality of references thereto, possibly from multiple clients. A discipline of permissions is imposed on the objects identified within the computer program module. The permissions enable tracking, from among a discrete set of changeable states, a subset of states each object might be in. A determination is made regarding whether the imposed permissions are violated by a potential reference to any of the identified objects. The results of the determination are output to a user.

  10. Computer Aided Design of Kaplan Turbine Piston with SolidWorks

    OpenAIRE

    Camelia Jianu

    2010-01-01

    The paper presents the steps for 3D computer aided design (CAD) of Kaplan turbine piston made in SolidWorks.The present paper is a tutorial for a Kaplan turbine piston 3D geometry, which is dedicaded to the Parts Sketch and Parts Features design and Drawing Geometry and Drawing Annotation.

  11. Segmentation and Location Computation of Bin Objects

    Directory of Open Access Journals (Sweden)

    C.R. Hema

    2008-11-01

    Full Text Available In this paper we present a stereo vision based system for segmentation and location computation of partially occluded objects in bin picking environments. Algorithms to segment partially occluded objects and to find the object location [midpoint,x, y and z coordinates] with respect to the bin area are proposed. The z co ordinate is computed using stereo images and neural networks. The proposed algorithms is tested using two neural network architectures namely the Radial Basis Function nets and Simple Feedforward nets. The training results fo feedforward nets are found to be more suitable for the current application.The proposed stereo vision system is interfaced with an Adept SCARA Robot to perform bin picking operations. The vision system is found to be effective for partially occluded objects, in the absence of albedo effects. The results are validated through real time bin picking experiments on the Adept Robot.

  12. Identification of computer graphics objects

    Directory of Open Access Journals (Sweden)

    Rossinskyi Yu.M.

    2016-04-01

    Full Text Available The article is devoted to the use of computer graphics methods in problems of creating drawings, charts, drafting, etc. The widespread use of these methods requires the development of efficient algorithms for the identification of objects of drawings. The article analyzes the model-making algorithms for this problem and considered the possibility of reducing the time using graphics editing operations. Editing results in such operations as copying, moving and deleting objects specified images. These operations allow the use of a reliable identification of images of objects methods. For information on the composition of the image of the object along with information about the identity and the color should include information about the spatial location and other characteristics of the object (the thickness and style of contour lines, fill style, and so on. In order to enable the pixel image analysis to structure the information it is necessary to enable the initial code image objects color. The article shows the results of the implementation of the algorithm of encoding object identifiers. To simplify the process of building drawings of any kind, and reduce time-consuming, method of drawing objects identification is proposed based on the use as the ID information of the object color.

  13. Visual objects and universal meanings: AIDS posters and the politics of globalisation and history.

    Science.gov (United States)

    Stein, Claudia; Cooter, Roger

    2011-01-01

    Drawing on recent visual and spatial turns in history writing, this paper considers AIDS posters from the perspective of their museum 'afterlife' as collected material objects. Museum spaces serve changing political and epistemological projects, and the visual objects they house are not immune from them. A recent globally themed exhibition of AIDS posters at an arts and crafts museum in Hamburg is cited in illustration. The exhibition also serves to draw attention to institutional continuities in collecting agendas. Revealed, contrary to postmodernist expectations, is how today's application of aesthetic display for the purpose of making 'global connections' does not radically break with the virtues and morals attached to the visual at the end of the nineteenth century. The historicisation of such objects needs to take into account this complicated mix of change and continuity in aesthetic concepts and political inscriptions. Otherwise, historians fall prey to seductive aesthetics without being aware of the politics of them. This article submits that aesthetics is politics.

  14. Visual Objects and Universal Meanings: AIDS Posters and the Politics of Globalisation and History

    Science.gov (United States)

    STEIN, CLAUDIA; COOTER, ROGER

    2011-01-01

    Drawing on recent visual and spatial turns in history writing, this paper considers AIDS posters from the perspective of their museum ‘afterlife’ as collected material objects. Museum spaces serve changing political and epistemological projects, and the visual objects they house are not immune from them. A recent globally themed exhibition of AIDS posters at an arts and crafts museum in Hamburg is cited in illustration. The exhibition also serves to draw attention to institutional continuities in collecting agendas. Revealed, contrary to postmodernist expectations, is how today’s application of aesthetic display for the purpose of making ‘global connections’ does not radically break with the virtues and morals attached to the visual at the end of the nineteenth century. The historicisation of such objects needs to take into account this complicated mix of change and continuity in aesthetic concepts and political inscriptions. Otherwise, historians fall prey to seductive aesthetics without being aware of the politics of them. This article submits that aesthetics is politics. PMID:23752866

  15. Integrating aerodynamic surface modeling for computational fluid dynamics with computer aided structural analysis, design, and manufacturing

    Science.gov (United States)

    Thorp, Scott A.

    1992-01-01

    This presentation will discuss the development of a NASA Geometry Exchange Specification for transferring aerodynamic surface geometry between LeRC systems and grid generation software used for computational fluid dynamics research. The proposed specification is based on a subset of the Initial Graphics Exchange Specification (IGES). The presentation will include discussion of how the NASA-IGES standard will accommodate improved computer aided design inspection methods and reverse engineering techniques currently being developed. The presentation is in viewgraph format.

  16. Computer-aided design of new metal binders

    International Nuclear Information System (INIS)

    Varnek, A.; Fourches, D.; Klimchuk, O.; Marcou, G.; Kireeva, N.; Tsivadze, A.; Solov'ev, V.

    2008-01-01

    Chemoinformatics approaches open new opportunities for computer-aided design of new efficient metal binders. Here, we demonstrate performances of ISIDA and COMET software tools to predict stability constants (log K) of the metal ion/organic ligand complexes in solution and to design in silico new molecules possessing desirable properties. The predictive models for log K of lanthanides complexation in water have been developed. Some new uranyl binders based on monoamides and on phosphoryl-containing podands were suggested theoretically, then synthesized and tested experimentally. Reasonable agreement between experimental uranyl distribution coefficients and theoretically predicted values has been observed. (orig.)

  17. Computer aided taxonomy (CAT): Approach for understanding systematics of marine biota

    Digital Repository Service at National Institute of Oceanography (India)

    Chavan, V.S.; Kavlekar, D.P.; Chandramohan, D.

    Computer aided taconomy (CAT) is gaining importance day by day. In order to familiarise the taxonomy and its continuing usage an attempt has made to develop a module for knowing the systematics of organisms and to generate automatic numerical code...

  18. [Research and application of computer-aided technology in restoration of maxillary defect].

    Science.gov (United States)

    Cheng, Xiaosheng; Liao, Wenhe; Hu, Qingang; Wang, Qian; Dai, Ning

    2008-08-01

    This paper presents a new method of designing restoration model of maxillectomy defect through Computer aided technology. Firstly, 3D maxillectomy triangle mesh model is constructed from Helical CT data. Secondly, the triangle mesh model is transformed into initial computer-aided design (CAD) model of maxillectomy through reverse engineering software. Thirdly, the 3D virtual restoration model of maxillary defect is obtained after designing and adjusting the initial CAD model through CAD software according to the patient's practical condition. Therefore, the 3D virtual restoration can be fitted very well with the broken part of maxilla. The exported design data can be manufactured using rapid prototyping technology and foundry technology. Finally, the result proved that this method is effective and feasible.

  19. Computer-aided design and computer-aided modeling (CAD/CAM) generated surgical splints, cutting guides and custom-made implants: Which indications in orthognathic surgery?

    Science.gov (United States)

    Scolozzi, P

    2015-12-01

    The purpose of the present report was to describe our indications, results and complications of computer-aided design and computer-aided modeling CAD/CAM surgical splints, cutting guides and custom-made implants in orthognathic surgery. We analyzed the clinical and radiological data of ten consecutive patients with dentofacial deformities treated using a CAD/CAM technique. Four patients had surgical splints and cutting guides for correction of maxillomandibular asymmetries, three had surgical cutting guides and customized internal distractors for correction of severe maxillary deficiencies and three had custom-made implants for additional chin contouring and/or mandibular defects following bimaxillary osteotomies and sliding genioplasty. We recorded age, gender, dentofacial deformity, surgical procedure and intra- and postoperative complications. All of the patients had stable cosmetic results with a high rate of patient satisfaction at the 1-year follow-up examination. No intra- and/or postoperative complications were encountered during any of the different steps of the procedure. This study demonstrated that the application of CAD/CAM patient-specific surgical splints, cutting guides and custom-made implants in orthognathic surgery allows for a successful outcome in the ten patients presented in this series. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  20. Effective Computer-Aided Assessment of Mathematics; Principles, Practice and Results

    Science.gov (United States)

    Greenhow, Martin

    2015-01-01

    This article outlines some key issues for writing effective computer-aided assessment (CAA) questions in subjects with substantial mathematical or statistical content, especially the importance of control of random parameters and the encoding of wrong methods of solution (mal-rules) commonly used by students. The pros and cons of using CAA and…

  1. Computer aided operation of the Karlsruhe isochronous cyclotron using CAMAC

    International Nuclear Information System (INIS)

    Kappel, W.; Karbstein, W.; Kneis, W.; Moellenbeck, J.; Schweickert, H.; Volk, B.

    1976-01-01

    An extensive branch system is used with a NOVA 2/10 computer as an aid to the operation of the Karlsruhe Isochronous Cyclotron. The accelerator operator calls the different tasks by an interactive program system ''CICERO'' under BASIC. CAMAC operations are called by means of the ordinary BASIC Call mechanism through assembler routines

  2. Color-coded perfusion analysis of CEUS for pre-interventional diagnosis of microvascularisation in cases of vascular malformations.

    Science.gov (United States)

    Teusch, V I; Wohlgemuth, W A; Piehler, A P; Jung, E M

    2014-01-01

    Aim of our pilot study was the application of a contrast-enhanced color-coded ultrasound perfusion analysis in patients with vascular malformations to quantify microcirculatory alterations. 28 patients (16 female, 12 male, mean age 24.9 years) with high flow (n = 6) or slow-flow (n = 22) malformations were analyzed before intervention. An experienced examiner performed a color-coded Doppler sonography (CCDS) and a Power Doppler as well as a contrast-enhanced ultrasound after intravenous bolus injection of 1 - 2.4 ml of a second-generation ultrasound contrast medium (SonoVue®, Bracco, Milan). The contrast-enhanced examination was documented as a cine sequence over 60 s. The quantitative analysis based on color-coded contrast-enhanced ultrasound (CEUS) images included percentage peak enhancement (%peak), time to peak (TTP), area under the curve (AUC), and mean transit time (MTT). No side effects occurred after intravenous contrast injection. The mean %peak in arteriovenous malformations was almost twice as high as in slow-flow-malformations. The area under the curve was 4 times higher in arteriovenous malformations compared to the mean value of other malformations. The mean transit time was 1.4 times higher in high-flow-malformations compared to slow-flow-malformations. There was no difference regarding the time to peak between the different malformation types. The comparison between all vascular malformation and surrounding tissue showed statistically significant differences for all analyzed data (%peak, TTP, AUC, MTT; p < 0.01). High-flow and slow-flow vascular malformations had statistically significant differences in %peak (p < 0.01), AUC analysis (p < 0.01), and MTT (p < 0.05). Color-coded perfusion analysis of CEUS seems to be a promising technique for the dynamic assessment of microvasculature in vascular malformations.

  3. Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing.

    Science.gov (United States)

    Gunsoy, S; Ulusoy, M

    2016-01-01

    The purpose of this study was to evaluate the internal and marginal fit of chrome cobalt (Co-Cr) crowns were fabricated with laser sintering, computer-aided design (CAD) and computer-aided manufacturing, and conventional methods. Polyamide master and working models were designed and fabricated. The models were initially designed with a software application for three-dimensional (3D) CAD (Maya, Autodesk Inc.). All models were fabricated models were produced by a 3D printer (EOSINT P380 SLS, EOS). 128 1-unit Co-Cr fixed dental prostheses were fabricated with four different techniques: Conventional lost wax method, milled wax with lost-wax method (MWLW), direct laser metal sintering (DLMS), and milled Co-Cr (MCo-Cr). The cement film thickness of the marginal and internal gaps was measured by an observer using a stereomicroscope after taking digital photos in ×24. Best fit rates according to mean and standard deviations of all measurements was in DLMS both in premolar (65.84) and molar (58.38) models in μm. A significant difference was found DLMS and the rest of fabrication techniques (P 0.05). DMLS was best fitting fabrication techniques for single crown based on the results.The best fit was found in marginal; the larger gap was found in occlusal.All groups were within the clinically acceptable misfit range.

  4. Orthodontics: computer-aided diagnosis and treatment planning

    Science.gov (United States)

    Yi, Yaxing; Li, Zhongke; Wei, Suyuan; Deng, Fanglin; Yao, Sen

    2000-10-01

    The purpose of this article is to introduce the outline of our newly developed computer-aided 3D dental cast analyzing system with laser scanning, and its preliminary clinical applications. The system is composed of a scanning device and a personal computer as a scanning controller and post processor. The scanning device is composed of a laser beam emitter, two sets of linear CCD cameras and a table which is rotatable by two-degree-of-freedom. The rotating is controlled precisely by a personal computer. The dental cast is projected and scanned with a laser beam. Triangulation is applied to determine the location of each point. Generation of 3D graphics of the dental cast takes approximately 40 minutes. About 170,000 sets of X,Y,Z coordinates are store for one dental cast. Besides the conventional linear and angular measurements of the dental cast, we are also able to demonstrate the size of the top surface area of each molar. The advantage of this system is that it facilitates the otherwise complicated and time- consuming mock surgery necessary for treatment planning in orthognathic surgery.

  5. The Power of Computer-aided Tomography to Investigate Marine Benthic Communities

    Science.gov (United States)

    Utilization of Computer-aided-Tomography (CT) technology is a powerful tool to investigate benthic communities in aquatic systems. In this presentation, we will attempt to summarize our 15 years of experience in developing specific CT methods and applications to marine benthic co...

  6. Design of tailor-made chemical blend using a decomposition-based computer-aided approach

    DEFF Research Database (Denmark)

    Yunus, Nor Alafiza; Gernaey, Krist; Manan, Z.A.

    2011-01-01

    Computer aided techniques form an efficient approach to solve chemical product design problems such as the design of blended liquid products (chemical blending). In chemical blending, one tries to find the best candidate, which satisfies the product targets defined in terms of desired product...... methodology for blended liquid products that identifies a set of feasible chemical blends. The blend design problem is formulated as a Mixed Integer Nonlinear Programming (MINLP) model where the objective is to find the optimal blended gasoline or diesel product subject to types of chemicals...... and their compositions and a set of desired target properties of the blended product as design constraints. This blend design problem is solved using a decomposition approach, which eliminates infeasible and/or redundant candidates gradually through a hierarchy of (property) model based constraints. This decomposition...

  7. CAESY - COMPUTER AIDED ENGINEERING SYSTEM

    Science.gov (United States)

    Wette, M. R.

    1994-01-01

    Many developers of software and algorithms for control system design have recognized that current tools have limits in both flexibility and efficiency. Many forces drive the development of new tools including the desire to make complex system modeling design and analysis easier and the need for quicker turnaround time in analysis and design. Other considerations include the desire to make use of advanced computer architectures to help in control system design, adopt new methodologies in control, and integrate design processes (e.g., structure, control, optics). CAESY was developed to provide a means to evaluate methods for dealing with user needs in computer-aided control system design. It is an interpreter for performing engineering calculations and incorporates features of both Ada and MATLAB. It is designed to be reasonably flexible and powerful. CAESY includes internally defined functions and procedures, as well as user defined ones. Support for matrix calculations is provided in the same manner as MATLAB. However, the development of CAESY is a research project, and while it provides some features which are not found in commercially sold tools, it does not exhibit the robustness that many commercially developed tools provide. CAESY is written in C-language for use on Sun4 series computers running SunOS 4.1.1 and later. The program is designed to optionally use the LAPACK math library. The LAPACK math routines are available through anonymous ftp from research.att.com. CAESY requires 4Mb of RAM for execution. The standard distribution medium is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. CAESY was developed in 1993 and is a copyrighted work with all copyright vested in NASA.

  8. Object-Oriented Modular Architecture for Ground Combat Simulation

    National Research Council Canada - National Science Library

    Luqi; Berzins, V; Shing, M; Saluto, M; Williams, J

    2000-01-01

    .... It describes the effective use of computer-aided prototyping techniques for re-engineering the legacy software to develop an object-oriented modular architecture for the Janus combat simulation system. Janus...

  9. Accelerating Development of EV Batteries Through Computer-Aided Engineering (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, A.; Kim, G. H.; Smith, K.; Santhanagopalan, S.

    2012-12-01

    The Department of Energy's Vehicle Technology Program has launched the Computer-Aided Engineering for Automotive Batteries (CAEBAT) project to work with national labs, industry and software venders to develop sophisticated software. As coordinator, NREL has teamed with a number of companies to help improve and accelerate battery design and production. This presentation provides an overview of CAEBAT, including its predictive computer simulation of Li-ion batteries known as the Multi-Scale Multi-Dimensional (MSMD) model framework. MSMD's modular, flexible architecture connects the physics of battery charge/discharge processes, thermal control, safety and reliability in a computationally efficient manner. This allows independent development of submodels at the cell and pack levels.

  10. Computer aided probabilistic assessment of containment integrity

    International Nuclear Information System (INIS)

    Tsai, J.C.; Touchton, R.A.

    1984-01-01

    In the probabilistic risk assessment (PRA) of a nuclear power plant, there are three probability-based techniques which are widely used for event sequence frequency quantification (including nodal probability estimation). These three techniques are the event tree analysis, the fault tree analysis and the Bayesian approach for database development. In the barrier analysis for assessing radionuclide release to the environment in a PRA study, these techniques are employed to a greater extent in estimating conditions which could lead to failure of the fuel cladding and the reactor coolant system (RCS) pressure boundary, but to a lesser degree in the containment pressure boundary failure analysis. The main reason is that containment issues are currently still in a state of flux. In this paper, the authors describe briefly the computer programs currently used by the nuclear industry to do event tree analyses, fault tree analyses and the Bayesian update. The authors discuss how these computer aided probabilistic techniques might be adopted for failure analysis of the containment pressure boundary

  11. Computer-aided training sensorimotor cortex functions in humans before the upper limb transplantation using virtual reality and sensory feedback.

    Science.gov (United States)

    Kurzynski, Marek; Jaskolska, Anna; Marusiak, Jaroslaw; Wolczowski, Andrzej; Bierut, Przemyslaw; Szumowski, Lukasz; Witkowski, Jerzy; Kisiel-Sajewicz, Katarzyna

    2017-08-01

    One of the biggest problems of upper limb transplantation is lack of certainty as to whether a patient will be able to control voluntary movements of transplanted hands. Based on findings of the recent research on brain cortex plasticity, a premise can be drawn that mental training supported with visual and sensory feedback can cause structural and functional reorganization of the sensorimotor cortex, which leads to recovery of function associated with the control of movements performed by the upper limbs. In this study, authors - based on the above observations - propose the computer-aided training (CAT) system, which generating visual and sensory stimuli, should enhance the effectiveness of mental training applied to humans before upper limb transplantation. The basis for the concept of computer-aided training system is a virtual hand whose reaching and grasping movements the trained patient can observe on the VR headset screen (visual feedback) and whose contact with virtual objects the patient can feel as a touch (sensory feedback). The computer training system is composed of three main components: (1) the system generating 3D virtual world in which the patient sees the virtual limb from the perspective as if it were his/her own hand; (2) sensory feedback transforming information about the interaction of the virtual hand with the grasped object into mechanical vibration; (3) the therapist's panel for controlling the training course. Results of the case study demonstrate that mental training supported with visual and sensory stimuli generated by the computer system leads to a beneficial change of the brain activity related to motor control of the reaching in the patient with bilateral upper limb congenital transverse deficiency. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Computer-aided load monitoring system for nuclear power plant steel framing structures

    International Nuclear Information System (INIS)

    Skaczylo, A.T.; Fung, S-J; Hooks, R.W.

    1984-01-01

    The design of nuclear power plant steel framing structures is a long and involved process. It is often complicated by numerous changes in design loads as a result of additions, deletions and modifications of HVAC hangers, cable tray hangers, electric conduit hangers, and small bore and large bore mechanical component supports. Manual tracking of load changes of thousands of supports and their impact to the structural steel design adequacy is very time-consuming and is susceptible to errors. This paper presents a computer-aided load monitoring system using the latest technology of data base management and interactive computer software. By linking the data base to analysis and investigation computer programs, the engineer has a very powerful tool to monitor not only the load revisions but also their impact on the steel structural floor framing members and connections. Links to reporting programs allow quick information retrieval in the form of comprehensive reports. Drawing programs extract data from the data base to draw hanger load system drawings on a computer-aided drafting system. These capabilities allow engineers to minimize modifications by strategically locating new hangers or rearranging auxiliary steel configuration

  13. Computer-aided diagnosis of early knee osteoarthritis based on MRI T2 mapping.

    Science.gov (United States)

    Wu, Yixiao; Yang, Ran; Jia, Sen; Li, Zhanjun; Zhou, Zhiyang; Lou, Ting

    2014-01-01

    This work was aimed at studying the method of computer-aided diagnosis of early knee OA (OA: osteoarthritis). Based on the technique of MRI (MRI: Magnetic Resonance Imaging) T2 Mapping, through computer image processing, feature extraction, calculation and analysis via constructing a classifier, an effective computer-aided diagnosis method for knee OA was created to assist doctors in their accurate, timely and convenient detection of potential risk of OA. In order to evaluate this method, a total of 1380 data from the MRI images of 46 samples of knee joints were collected. These data were then modeled through linear regression on an offline general platform by the use of the ImageJ software, and a map of the physical parameter T2 was reconstructed. After the image processing, the T2 values of ten regions in the WORMS (WORMS: Whole-organ Magnetic Resonance Imaging Score) areas of the articular cartilage were extracted to be used as the eigenvalues in data mining. Then,a RBF (RBF: Radical Basis Function) network classifier was built to classify and identify the collected data. The classifier exhibited a final identification accuracy of 75%, indicating a good result of assisting diagnosis. Since the knee OA classifier constituted by a weights-directly-determined RBF neural network didn't require any iteration, our results demonstrated that the optimal weights, appropriate center and variance could be yielded through simple procedures. Furthermore, the accuracy for both the training samples and the testing samples from the normal group could reach 100%. Finally, the classifier was superior both in time efficiency and classification performance to the frequently used classifiers based on iterative learning. Thus it was suitable to be used as an aid to computer-aided diagnosis of early knee OA.

  14. Implementing version support for complex objects

    NARCIS (Netherlands)

    Blanken, Henk

    New applications in the area of office information systems, computer aided design and manufacturing make new demands upon database management systems. Among others highly structured objects and their history have to be represented and manipulated. The paper discusses some general problems concerning

  15. Computer-aided drug discovery [v1; ref status: indexed, http://f1000r.es/5ij

    Directory of Open Access Journals (Sweden)

    Jürgen Bajorath

    2015-08-01

    Full Text Available Computational approaches are an integral part of interdisciplinary drug discovery research. Understanding the science behind computational tools, their opportunities, and limitations is essential to make a true impact on drug discovery at different levels. If applied in a scientifically meaningful way, computational methods improve the ability to identify and evaluate potential drug molecules, but there remain weaknesses in the methods that preclude naïve applications. Herein, current trends in computer-aided drug discovery are reviewed, and selected computational areas are discussed. Approaches are highlighted that aid in the identification and optimization of new drug candidates. Emphasis is put on the presentation and discussion of computational concepts and methods, rather than case studies or application examples. As such, this contribution aims to provide an overview of the current methodological spectrum of computational drug discovery for a broad audience.

  16. Article Commentary: Computer-Aided Detection of Breast Cancer — Have All Bases Been Covered?

    Directory of Open Access Journals (Sweden)

    Gautam S. Muralidhar

    2008-01-01

    Full Text Available The use of computer-aided detection (CAD systems in mammography has been the subject of intense research for many years. These systems have been developed with the aim of helping radiologists to detect signs of breast cancer. However, the effectiveness of CAD systems in practice has sparked recent debate. In this commentary, we argue that computer-aided detection will become an increasingly important tool for radiologists in the early detection of breast cancer, but there are some important issues that need to be given greater focus in designing CAD systems if they are to reach their full potential.

  17. A PC Mathcad-based computational aid for severe accident analysis and its application to a BWR small LOCA sequence

    International Nuclear Information System (INIS)

    Wu, Laung-Kuang T.; Lee, S.J.

    2004-01-01

    A PC-based Mathcad program is used to develop a computational aid for analyzing severe accident phenomena. This computational aid uses simple engineering expressions and empirical correlations to estimate key quantities and timings at various stages of accident progressions. In this paper, the computational aid is applied to analyze an early phase of a BWR small LOCA sequence. The accident phenomena analyzed include: break flow rates, boiled-up water level in the core, core uncovery time, depressurization of the reactor pressure vessel, core heat-up, onset of clad oxidation, hydrogen generation, and onset of fuel relocation. The results are compared with those obtained running the MAAP 3.0B code. This PC-based computational aid can be used to train plant personnel in understanding severe accident phenomena and to assist them in managing severe accidents. (author)

  18. Computer aided approach to qualitative and quantitative common cause failure analysis for complex systems

    International Nuclear Information System (INIS)

    Cate, C.L.; Wagner, D.P.; Fussell, J.B.

    1977-01-01

    Common cause failure analysis, also called common mode failure analysis, is an integral part of a complete system reliability analysis. Existing methods of computer aided common cause failure analysis are extended by allowing analysis of the complex systems often encountered in practice. The methods aid in identifying potential common cause failures and also address quantitative common cause failure analysis

  19. Evaluation of the fracture resistance of computer-aided design/computer-aided manufacturing monolithic crowns prepared in different cement thicknesses.

    Science.gov (United States)

    Sagsoz, N Polat; Yanıkoglu, N

    2018-04-01

    The purpose of this study was to evaluate the fracture resistance of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) crowns that are prepared with different cement thickness. For this investigation, a human maxillary premolar tooth was selected. Master model preparation was performed with a demand bur under water spray. Master die was taken to fabricate 105 epoxy resin replicas. The crowns were milled using a CEREC 4 CAD/CAM system (Software Version, 4.2.0.57192). CAD/CAM crowns were made using resin nanoceramic, feldspathic glass ceramic, lithium disilicate, and leucite-reinforced ceramics. Each group was subdivided into three groups in accordance with three different cement thicknesses (30, 90, and 150 μm). Crowns milled out. Then RelyX ™ U200 was used as a luting agent to bond the crowns to the prepared samples. After one hour cementations, the specimens were stored in water bath at 37°C for 1 week before testing. Seven unprepared and unrestored teeth were kept and tested as a control group. A universal test machine was used to assume the fracture resistance of all specimens. The compressive load (N) that caused fracture was recorded for each specimen. Fracture resistance data were statistically analyzed by one-way ANOVA and two-factor interaction modeling test (α = 0.001). There are statistically significant differences between fracture resistances of CAD/CAM monolithic crown materials (P cement thickness is not statistically significant for fracture resistance of CAD/CAM monolithic crowns (P > 0.001). CAD/CAM monolithic crown materials affected fracture resistance. Cement thickness (30, 90, and 150 μm) was not effective on fracture resistance of CAD/CAM monolithic crowns.

  20. On the convergence of nanotechnology and Big Data analysis for computer-aided diagnosis.

    Science.gov (United States)

    Rodrigues, Jose F; Paulovich, Fernando V; de Oliveira, Maria Cf; de Oliveira, Osvaldo N

    2016-04-01

    An overview is provided of the challenges involved in building computer-aided diagnosis systems capable of precise medical diagnostics based on integration and interpretation of data from different sources and formats. The availability of massive amounts of data and computational methods associated with the Big Data paradigm has brought hope that such systems may soon be available in routine clinical practices, which is not the case today. We focus on visual and machine learning analysis of medical data acquired with varied nanotech-based techniques and on methods for Big Data infrastructure. Because diagnosis is essentially a classification task, we address the machine learning techniques with supervised and unsupervised classification, making a critical assessment of the progress already made in the medical field and the prospects for the near future. We also advocate that successful computer-aided diagnosis requires a merge of methods and concepts from nanotechnology and Big Data analysis.

  1. Differentiation of diffuse liver disease with computer-aided tissue echo quantification

    International Nuclear Information System (INIS)

    Cha, Joo Hee; Choi, Byung Ihm; Yun, Eun Joo; Ko, Young Hwan; Song, Chi Sung; Kim, Seung Hyup; Han, Joon Koo; Kim, Tae Kyoung; Lee, Dong Hyuk; Kim, Jong Hyo

    1999-01-01

    The purpose of this study was to evaluate the efficacy of computer-aided tissue echo quantification technique in the differentiation of diffuse liver diseases. Sixty-five patients with chronic liver disease including chronic hepatitis in 21 patients, fatty liver in 11, and liver cirrhosis in 33, and 55 normal volunteers were included in this study. The sonographic images by the Sono-PACS(MARO, Seoul) was recalled and the analysis was done for the hepatic parenchymal coarseness by the program using Visual C++. Difference histogram variation (DHV), edge density (ED) and intertia of concurrence matrix (ICM) were used as the coarseness index. These three indexes were statistically significant (p<0.05) in the differentiation of these four groups. The accuracy of the differentiation between any two of four groups was 83.0%. The accuracy of the differentiation of these four groups was 70.8% at the same time. The computer-aided tissue echo quantification technique is a complementary study for the differentiation of diffuse liver disease.

  2. Computer-Aided Design of Antimicrobial Peptides

    DEFF Research Database (Denmark)

    Fjell, Christopher D.; Hancock, Robert E.W.; Jenssen, Håvard

    2010-01-01

    in antimicrobial activity. Consequently, the majority of peptides put into clinical trials have failed at some point, underlining the importance of a thorough peptide optimization. An important tool in peptide design and optimization is quantitative structure-activity relationship (QSAR) analysis, correlating...... chemical parameters with biological activities of the peptide, using statistical methods. In this review we will discuss two different in silico strategies of computer-aided antibacterial peptide design, a linear correlation model build as an extension of traditional principal component analysis (PCA......) and a non-linear artificial neural network model. Studies on structurally diverse peptides, have concluded that the PCA derived model are able to guide the antibacterial peptide design in a meaningful way, however requiring rather a high homology between the peptides in the test-set and the in silico...

  3. Implementing interactive computing in an object-oriented environment

    Directory of Open Access Journals (Sweden)

    Frederic Udina

    2000-04-01

    Full Text Available Statistical computing when input/output is driven by a Graphical User Interface is considered. A proposal is made for automatic control of computational flow to ensure that only strictly required computations are actually carried on. The computational flow is modeled by a directed graph for implementation in any object-oriented programming language with symbolic manipulation capabilities. A complete implementation example is presented to compute and display frequency based piecewise linear density estimators such as histograms or frequency polygons.

  4. Technology computer aided design simulation for VLSI MOSFET

    CERN Document Server

    Sarkar, Chandan Kumar

    2013-01-01

    Responding to recent developments and a growing VLSI circuit manufacturing market, Technology Computer Aided Design: Simulation for VLSI MOSFET examines advanced MOSFET processes and devices through TCAD numerical simulations. The book provides a balanced summary of TCAD and MOSFET basic concepts, equations, physics, and new technologies related to TCAD and MOSFET. A firm grasp of these concepts allows for the design of better models, thus streamlining the design process, saving time and money. This book places emphasis on the importance of modeling and simulations of VLSI MOS transistors and

  5. Computer aided approach for qualitative risk assessment of engineered systems

    International Nuclear Information System (INIS)

    Crowley, W.K.; Arendt, J.S.; Fussell, J.B.; Rooney, J.J.; Wagner, D.P.

    1978-01-01

    This paper outlines a computer aided methodology for determining the relative contributions of various subsystems and components to the total risk associated with an engineered system. Major contributors to overall task risk are identified through comparison of an expected frequency density function with an established risk criterion. Contributions that are inconsistently high are also identified. The results from this analysis are useful for directing efforts for improving system safety and performance. An analysis of uranium hexafluoride handling risk at a gaseous diffusion uranium enrichment plant using a preliminary version of the computer program EXCON is briefly described and illustrated

  6. Three-class classification in computer-aided diagnosis of breast cancer by support vector machine

    Science.gov (United States)

    Sun, Xuejun; Qian, Wei; Song, Dansheng

    2004-05-01

    Design of classifier in computer-aided diagnosis (CAD) scheme of breast cancer plays important role to its overall performance in sensitivity and specificity. Classification of a detected object as malignant lesion, benign lesion, or normal tissue on mammogram is a typical three-class pattern recognition problem. This paper presents a three-class classification approach by using two-stage classifier combined with support vector machine (SVM) learning algorithm for classification of breast cancer on mammograms. The first classification stage is used to detect abnormal areas and normal breast tissues, and the second stage is for classification of malignant or benign in detected abnormal objects. A series of spatial, morphology and texture features have been extracted on detected objects areas. By using genetic algorithm (GA), different feature groups for different stage classification have been investigated. Computerized free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) analyses have been employed in different classification stages. Results have shown that obvious performance improvement in both sensitivity and specificity was observed through proposed classification approach compared with conventional two-class classification approaches, indicating its effectiveness in classification of breast cancer on mammograms.

  7. New Method and Software for Computer-Aided Flowsheet Design and Analysis

    DEFF Research Database (Denmark)

    K.Tula, Anjan; Gani, Rafiqul; Eden, Mario R.

    2017-01-01

    in the same way as atoms or groups of atoms are synthesized to form molecules in computer aided molecular design (CAMD) techniques. Another important aspect of this method is the integration of economic, sustainability and LCA analyses in the early stages of process synthesis to identify process hotspots...

  8. Computer aided process control equipment at the Karlsruhe reprocessing pilot plant, WAK

    International Nuclear Information System (INIS)

    Winter, R.; Finsterwalder, L.; Gutzeit, G.; Reif, J.; Stollenwerk, A.H.; Weinbrecht, E.; Weishaupt, M.

    1991-01-01

    A computer aided process control system has been installed at the Karlsruhe Spent Fuel Reprocessing Plant, WAK. All necessary process control data of the first extraction cycle is collected via a data collection system and is displayed in suitable ways on a screen for the operator in charge of the unit. To aid verification of displayed data, various measurements are associated to each other using balance type process modeling. Thus, deviation of flowsheet conditions and malfunctioning of measuring equipment are easily detected. (orig.) [de

  9. Computer-Aided Design/Computer-Assisted Manufacture Monolithic Restorations for Severely Worn Dentition: A Case History Report.

    Science.gov (United States)

    Abou-Ayash, Samir; Boldt, Johannes; Vuck, Alexander

    Full-arch rehabilitation of patients with severe tooth wear due to parafunctional behavior is a challenge for dentists and dental technicians, especially when a highly esthetic outcome is desired. A variety of different treatment options and prosthetic materials are available for such a clinical undertaking. The ongoing progress of computer-aided design/computer-assisted manufacture technologies in combination with all-ceramic materials provides a predictable workflow for these complex cases. This case history report describes a comprehensive, step-by-step treatment protocol leading to an optimally predictable treatment outcome for an esthetically compromised patient.

  10. Tailor-made Design of Chemical Blends using Decomposition-based Computer-aided Approach

    DEFF Research Database (Denmark)

    Yunus, Nor Alafiza; Manan, Zainuddin Abd.; Gernaey, Krist

    (properties). In this way, first the systematic computer-aided technique establishes the search space, and then narrows it down in subsequent steps until a small number of feasible and promising candidates remain and then experimental work may be conducted to verify if any or all the candidates satisfy......Computer aided technique is an efficient approach to solve chemical product design problems such as design of blended liquid products (chemical blending). In chemical blending, one tries to find the best candidate, which satisfies the product targets defined in terms of desired product attributes...... is decomposed into two stages. The first stage investigates the mixture stability where all unstable mixtures are eliminated and the stable blend candidates are retained for further testing. In the second stage, the blend candidates have to satisfy a set of target properties that are ranked according...

  11. Image-processing techniques used in the computer-aided detection of radiographic lesions in anatomic background

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.; Yin, F.F.

    1988-01-01

    The authors developed feature-extraction techniques for use in the computer-aided detection of pulmonary nodules in digital chest images. Use of such a computer-aided detection scheme, which would alert radiologists to the locations of suspected lung nodules, is expected to reduce the number of false-negative diagnoses. False-negative diagnoses (i.e., misses) are a current problem in chest radiology with ''miss-rates'' as high as 30%. This may be due to the camouflaging effect of surrounding anatomic background on the nodule, or to the subjective and varying decision criteria used by radiologists

  12. Using Computer Technology To Aid the Disabled Reader.

    Science.gov (United States)

    Balajthy, Ernest

    When matched for achievement level and educational objectives, computer technology can be particularly effective with at-risk students. Computer-assisted instructional software is the most widely available type of software. An exciting development pertinent to literacy education is the development of the "electronic book" (also called…

  13. Incorporating Computer-Aided Software in the Undergraduate Chemical Engineering Core Courses

    Science.gov (United States)

    Alnaizy, Raafat; Abdel-Jabbar, Nabil; Ibrahim, Taleb H.; Husseini, Ghaleb A.

    2014-01-01

    Introductions of computer-aided software and simulators are implemented during the sophomore-year of the chemical engineering (ChE) curriculum at the American University of Sharjah (AUS). Our faculty concurs that software integration within the curriculum is beneficial to our students, as evidenced by the positive feedback received from industry…

  14. Teaching Neuroanatomy Using Computer-Aided Learning: What Makes for Successful Outcomes?

    Science.gov (United States)

    Svirko, Elena; Mellanby, Jane

    2017-01-01

    Computer-aided learning (CAL) is an integral part of many medical courses. The neuroscience course at Oxford University for medical students includes CAL course of neuroanatomy. CAL is particularly suited to this since neuroanatomy requires much detailed three-dimensional visualization, which can be presented on screen. The CAL course was…

  15. [Computer aided diagnosis model for lung tumor based on ensemble convolutional neural network].

    Science.gov (United States)

    Wang, Yuanyuan; Zhou, Tao; Lu, Huiling; Wu, Cuiying; Yang, Pengfei

    2017-08-01

    The convolutional neural network (CNN) could be used on computer-aided diagnosis of lung tumor with positron emission tomography (PET)/computed tomography (CT), which can provide accurate quantitative analysis to compensate for visual inertia and defects in gray-scale sensitivity, and help doctors diagnose accurately. Firstly, parameter migration method is used to build three CNNs (CT-CNN, PET-CNN, and PET/CT-CNN) for lung tumor recognition in CT, PET, and PET/CT image, respectively. Then, we aimed at CT-CNN to obtain the appropriate model parameters for CNN training through analysis the influence of model parameters such as epochs, batchsize and image scale on recognition rate and training time. Finally, three single CNNs are used to construct ensemble CNN, and then lung tumor PET/CT recognition was completed through relative majority vote method and the performance between ensemble CNN and single CNN was compared. The experiment results show that the ensemble CNN is better than single CNN on computer-aided diagnosis of lung tumor.

  16. Study of the computer-aided implantation and layout of printed circuits

    International Nuclear Information System (INIS)

    Baudry, Marc

    1973-01-01

    This research thesis reports the design and implementation of a software aimed at a computer-aided implantation and layout of printed circuits. This work comprises the use of heuristic algorithms and the search for a minimum cost by reduction of computing time and of memory size. The software comprises four independent parts which respectively address data analysis and control, circuit implantation, connection layout, and the exploitation of the obtained results. These four parts and their subroutines are presented. Two examples are reported in appendix

  17. Computer-aided design of bromelain and papain covalent immobilization

    OpenAIRE

    Bessy Cutiño-Avila; Dayrom Gil Pradas; Carlos Aragón Abreu; Yuniel Fernández Marrero; Martha Hernández de la Torre; Emir Salas Sarduy; María de los Ángeles Chávez Planes; José Manuel Guisán Seijas; Joaquín Díaz Brito; Alberto del Monte-Martínez

    2014-01-01

    Título en español: Diseño asistido por computadora de la inmovilización covalente de bromelina y papaína. Título corto: Computer-aided design of bromelain and papain.  Abstract: Enzymes as immobilized derivatives have been widely used in Food, Agrochemical, Pharmaceutical and Biotechnological industries. Protein immobilization is probably the most used technology to improve the operational stability of these molecules. Bromelain (Ananas comosus) and papain (Carica papaya) are cystein pr...

  18. Contributions on Computer Aided Manufacturing of Drill-Jig Bushings

    Directory of Open Access Journals (Sweden)

    Vasile Cojocaru

    2009-01-01

    Full Text Available The paper presents the steps for computer aided manufacturing (CAMof the bushings technological class parts: design of the part in CADsoftware; generation of the parametrical link with MSExcel files; extract of the useful information for the technological design (mass, volume, surfaces; setting of the CNC lathe and necessary tools; programming of the CNC code for manufacturing. Given the large variety of the bushingsshapes and dimensions, the application focused on the jig bushings used in drilling processes.

  19. Computer aided detection system for lung cancer using computer tomography scans

    Science.gov (United States)

    Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.

    2018-04-01

    Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.

  20. [Influence of coping material selection and porcelain firing on marginal and internal fit of computer-aided design/computer- aided manufacturing of zirconia and titanium ceramic implant-supported crowns].

    Science.gov (United States)

    Cuiling, Liu; Liyuan, Yang; Xu, Gao; Hong, Shang

    2016-06-01

    This study aimed to investigate the influence of coping material and porcelain firing on the marginal and internal fit of computer-aided design/computer-aided manufacturing (CAD/CAM) of zirconia ceramic implant- and titanium ceramic implant-supported crowns. Zirconia ceramic implant (group A, n = 8) and titanium metal ceramic implant-supported crowns (group B, n = 8) were produced from copings using the CAD/CAM system. The marginal and internal gaps of the copings and crowns were measured by using a light-body silicone replica technique combined with micro-computed tomography scanning to obtain a three-dimensional image. Marginal gap (MG), horizontal marginal discrepancy (HMD), and axial wall (AW) were measured. Statistical analyses were performed using SPSS 17.0. Prior to porcelain firing, the measurements for MG, HMD, and AW of copings in group A were significantly larger than those in group B (P 0.05). Porcelain firing significantly reduced MG (P 0.05). The marginal fits of CAD/CAM zirconia ceramic implant-supported crowns were superior to those of CAD/CAM titanium ceramic-supported crowns. The fits of both the CAD/CAM zirconia ceramic implant- and titanium ceramic implant-supported crowns were obviously influenced by porcelain firing.

  1. Computer-aided position planning of miniplates to treat facial bone defects.

    Directory of Open Access Journals (Sweden)

    Jan Egger

    Full Text Available In this contribution, a software system for computer-aided position planning of miniplates to treat facial bone defects is proposed. The intra-operatively used bone plates have to be passively adapted on the underlying bone contours for adequate bone fragment stabilization. However, this procedure can lead to frequent intra-operatively performed material readjustments especially in complex surgical cases. Our approach is able to fit a selection of common implant models on the surgeon's desired position in a 3D computer model. This happens with respect to the surrounding anatomical structures, always including the possibility of adjusting both the direction and the position of the used osteosynthesis material. By using the proposed software, surgeons are able to pre-plan the out coming implant in its form and morphology with the aid of a computer-visualized model within a few minutes. Further, the resulting model can be stored in STL file format, the commonly used format for 3D printing. Using this technology, surgeons are able to print the virtual generated implant, or create an individually designed bending tool. This method leads to adapted osteosynthesis materials according to the surrounding anatomy and requires further a minimum amount of money and time.

  2. Computer-aided position planning of miniplates to treat facial bone defects

    Science.gov (United States)

    Wallner, Jürgen; Gall, Markus; Chen, Xiaojun; Schwenzer-Zimmerer, Katja; Reinbacher, Knut; Schmalstieg, Dieter

    2017-01-01

    In this contribution, a software system for computer-aided position planning of miniplates to treat facial bone defects is proposed. The intra-operatively used bone plates have to be passively adapted on the underlying bone contours for adequate bone fragment stabilization. However, this procedure can lead to frequent intra-operatively performed material readjustments especially in complex surgical cases. Our approach is able to fit a selection of common implant models on the surgeon’s desired position in a 3D computer model. This happens with respect to the surrounding anatomical structures, always including the possibility of adjusting both the direction and the position of the used osteosynthesis material. By using the proposed software, surgeons are able to pre-plan the out coming implant in its form and morphology with the aid of a computer-visualized model within a few minutes. Further, the resulting model can be stored in STL file format, the commonly used format for 3D printing. Using this technology, surgeons are able to print the virtual generated implant, or create an individually designed bending tool. This method leads to adapted osteosynthesis materials according to the surrounding anatomy and requires further a minimum amount of money and time. PMID:28817607

  3. Computer-aided diagnostic system for detection of Hashimoto thyroiditis on ultrasound images from a Polish population.

    Science.gov (United States)

    Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S

    2014-02-01

    Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.

  4. An ODP computational model of a cooperative binding object

    Science.gov (United States)

    Logé, Christophe; Najm, Elie; Chen, Ken

    1997-12-01

    A next generation of systems that should appear will have to manage simultaneously several geographically distributed users. These systems belong to the class of computer-supported cooperative work systems (CSCW). The development of such complex systems requires rigorous development methods and flexible open architectures. Open distributed processing (ODP) is a standardization effort that aims at providing such architectures. ODP features appropriate abstraction levels and a clear articulation between requirements, programming and infrastructure support. ODP advocates the use of formal methods for the specification of systems and components. The computational model, an object-based model, one of the abstraction levels identified within ODP, plays a central role in the global architecture. In this model, basic objects can be composed with communication and distribution abstractions (called binding objects) to form a computational specification of distributed systems, or applications. Computational specifications can then be mapped (in a mechanism akin to compilation) onto an engineering solution. We use an ODP-inspired method to computationally specify a cooperative system. We start from a general purpose component that we progressively refine into a collection of basic and binding objects. We focus on two issues of a co-authoring application, namely, dynamic reconfiguration and multiview synchronization. We discuss solutions for these issues and formalize them using the MT-LOTOS specification language that is currently studied in the ISO standardization formal description techniques group.

  5. A computer-aided diagnostic and troubleshooting system for fuel cell power plants

    International Nuclear Information System (INIS)

    Unkle, C.R.

    1990-10-01

    This Interactive Computer-Aided Troubleshooting System (ICATS) was designed as a troubleshooting aid for the Tokyo Electric Power Company (TEPCO) 11-megawatt dc Module (DCM). ICATS represents an integration of the System Testability and Maintenance Program (STAMP reg-sign) and the Portable Interactive Troubleshooter (POINTER trademark) software packages developed by ARINC Research Corporation. ICATS was designed to aid in the fault isolation of shutdown conditions that may occur in the DCM during on-load operations and start-up, and hold conditions that may occur during start-up. ICATS may also be used to help fault-isolate a return-to-standby condition occurring from on-load operation of the DCM. This report describes the development of ICATS and the ICATS functional design. The unique features of STAMP and POINTER, which allow for diagnostic aids to be designed for systems not yet built and operating, are also described. 10 refs., 21 figs., 6 tabs

  6. Computer aided materials design; Keisanki zairyo sekkei

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The questionnaire survey on the computer aided materials design (CAMD), and the survey of current domestic and overseas software concerned were carried out to clarify developmental issues. The current elementary technology of CAMD was also surveyed to study its several problems caused with a progress of material design technology due to drastic diffusion of CAMD. This project aims at establishment of a new demanded software, computer chemistry, focusing attention on functional materials such as catalyst, polymer and non-linear electronic materials. Microscopic simulation technology was mainly surveyed in fiscal 1996. Although some fruitful results have been obtained in the fields of medical and agricultural chemicals, organic compounds, proteins, catalysts and electronic materials, such some problems are pointed out as `CAMD cannot handle an actual size of the target system` and `commercially available software are very expensive.` Reliable tool development as elementary technology, and the verification of its applications are thus required. Meso-dynamics, polymers, surface reaction and integrated technological environment attract users` attention. 27 refs., 16 figs., 2 tabs.

  7. Computed tomography for diagnosis of intestinal cytomegalovirus infection in AIDS

    International Nuclear Information System (INIS)

    Engelbrecht, V.; Schonlau, R.; Moedder, U.

    1994-01-01

    To check the value of computed tomography (CT) in the diagnosis of cytomegalovirus (CMV) infection of the intestine, CT findings in ten patients with coloscopically proven CMV infection were reviewed. All patients were chronically ill men with AIDS. In nine of the ten cases CT scans of the small intestine and/or colon disclosed abnormalities. The predominant alteration (9/9) was a symmetric wall thickening in the bowel segments involved (10-30 mm). The location and extent showed good agreement with the inflammatory areas seen on coloscopy. The cecum and terminal ileum were the regions most frequently affected. In seven of the nine patients with CT abnormalities CT revealed pericolonic inflammation, particularly around the cecum. Lymph nodes were increased but not enlarged. Comparison of the findings in intestinal CMV infection with those in other AIDS-related diseases suggests that CT may be to limit the differential diagnosis. Abdominal CT serves as suitable primary imaging modality for the initial evaluation of patients with AIDS and abdominal symptoms of unknow etiology. (orig.)

  8. Evolution of facility layout requirements and CAD [computer-aided design] system development

    International Nuclear Information System (INIS)

    Jones, M.

    1990-06-01

    The overall configuration of the Superconducting Super Collider (SSC) including the infrastructure and land boundary requirements were developed using a computer-aided design (CAD) system. The evolution of the facility layout requirements and the use of the CAD system are discussed. The emphasis has been on minimizing the amount of input required and maximizing the speed by which the output may be obtained. The computer system used to store the data is also described

  9. A study on NMI report generation with computer aid diagnosis

    International Nuclear Information System (INIS)

    Yang Xiaona; Li Zhimin; Zhao Xiangjun; Qiu Jinping

    1994-01-01

    An expert system of intelligent diagnosis, computer aid diagnosis and computerized report generation and management for an nuclear medicine imaging (NMI) was performed. The mathematic model with finite set mapping for the diagnosis was evaluated. The clinical application shows, the diagnostic sensitivity and specificity of it was 85.7% ∼ 93.4% and 92% ∼ 95.6% respectively. Therefore, its application may be extended

  10. Computer aided analysis, simulation and optimisation of thermal sterilisation processes.

    Science.gov (United States)

    Narayanan, C M; Banerjee, Arindam

    2013-04-01

    Although thermal sterilisation is a widely employed industrial process, little work is reported in the available literature including patents on the mathematical analysis and simulation of these processes. In the present work, software packages have been developed for computer aided optimum design of thermal sterilisation processes. Systems involving steam sparging, jacketed heating/cooling, helical coils submerged in agitated vessels and systems that employ external heat exchangers (double pipe, shell and tube and plate exchangers) have been considered. Both batch and continuous operations have been analysed and simulated. The dependence of del factor on system / operating parameters such as mass or volume of substrate to be sterilised per batch, speed of agitation, helix diameter, substrate to steam ratio, rate of substrate circulation through heat exchanger and that through holding tube have been analysed separately for each mode of sterilisation. Axial dispersion in the holding tube has also been adequately accounted for through an appropriately defined axial dispersion coefficient. The effect of exchanger characteristics/specifications on the system performance has also been analysed. The multiparameter computer aided design (CAD) software packages prepared are thus highly versatile in nature and they permit to make the most optimum choice of operating variables for the processes selected. The computed results have been compared with extensive data collected from a number of industries (distilleries, food processing and pharmaceutical industries) and pilot plants and satisfactory agreement has been observed between the two, thereby ascertaining the accuracy of the CAD softwares developed. No simplifying assumptions have been made during the analysis and the design of associated heating / cooling equipment has been performed utilising the most updated design correlations and computer softwares.

  11. Computer-based learning--an aid to successful teaching of pharmacology?

    Science.gov (United States)

    E Hughes, Ian

    2002-07-01

    Various types of software have been developed for use in pharmacology courses. These include: simple drill (question and answer) software; electronic books; video material; tutorial type programs; simulations; and electronic learning environments for course organisation and delivery. These different types of software can be used in different ways to achieve very different learning objectives and gains in teaching efficiency. For example, software can be used: in tutorial and small group teaching; in lectures; to better prepare students for practical work; as a replacement for practicals; to provide options within a limited course structure; to supplement lectures and enable students to work at their own pace; to provide ongoing access to self-assessment throughout a course; to aid distance learning; as remedial teaching and to extend the student learning experience in areas which are too expensive or too time consuming or for which staff expertise does not exist. Evidence indicates that it is insufficient simply to make computer based learning material available to students. Like a laboratory class, it must be fully integrated into a module if real benefits are to be obtained. Students need to be taught how to learn from computer-based learning materials and how to integrate this learning tool in their learning strategy. Teachers need to be supported not only with information about the availability of software but, equally importantly, about how it can be integrated into modules. We are all delivering teaching and facilitating learning in a changing environment and subject to a variety of increasing pressures. It may well be that computer based learning materials may help to maintain a high quality of pharmacology teaching within this changing environment but we need more pedagogical research at the discipline level to establish how this can best be done.

  12. Computer-aided detection in breast MRI : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Dorrius, Monique D.; Jansen-van der Weide, Marijke C.; van Ooijen, Peter M. A.; Pijnappel, Ruud M.; Oudkerk, Matthijs

    To evaluate the additional value of computer-aided detection (CAD) in breast MRI by assessing radiologists' accuracy in discriminating benign from malignant breast lesions. A literature search was performed with inclusion of relevant studies using a commercially available CAD system with automatic

  13. DEVELOPMENT AND USE OF COMPUTER-AIDED PROCESS ENGINEERING TOOLS FOR POLLUTION PREVENTION

    Science.gov (United States)

    The use of Computer-Aided Process Engineering (CAPE) and process simulation tools has become established industry practice to predict simulation software, new opportunities are available for the creation of a wide range of ancillary tools that can be used from within multiple sim...

  14. Computer-Aided Grading of Gliomas Combining Automatic Segmentation and Radiomics

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2018-01-01

    Full Text Available Gliomas are the most common primary brain tumors, and the objective grading is of great importance for treatment. This paper presents an automatic computer-aided diagnosis of gliomas that combines automatic segmentation and radiomics, which can improve the diagnostic ability. The MRI data containing 220 high-grade gliomas and 54 low-grade gliomas are used to evaluate our system. A multiscale 3D convolutional neural network is trained to segment whole tumor regions. A wide range of radiomic features including first-order features, shape features, and texture features is extracted. By using support vector machines with recursive feature elimination for feature selection, a CAD system that has an extreme gradient boosting classifier with a 5-fold cross-validation is constructed for the grading of gliomas. Our CAD system is highly effective for the grading of gliomas with an accuracy of 91.27%, a weighted macroprecision of 91.27%, a weighted macrorecall of 91.27%, and a weighted macro-F1 score of 90.64%. This demonstrates that the proposed CAD system can assist radiologists for high accurate grading of gliomas and has the potential for clinical applications.

  15. Toward a Computer Vision-based Wayfinding Aid for Blind Persons to Access Unfamiliar Indoor Environments.

    Science.gov (United States)

    Tian, Yingli; Yang, Xiaodong; Yi, Chucai; Arditi, Aries

    2013-04-01

    Independent travel is a well known challenge for blind and visually impaired persons. In this paper, we propose a proof-of-concept computer vision-based wayfinding aid for blind people to independently access unfamiliar indoor environments. In order to find different rooms (e.g. an office, a lab, or a bathroom) and other building amenities (e.g. an exit or an elevator), we incorporate object detection with text recognition. First we develop a robust and efficient algorithm to detect doors, elevators, and cabinets based on their general geometric shape, by combining edges and corners. The algorithm is general enough to handle large intra-class variations of objects with different appearances among different indoor environments, as well as small inter-class differences between different objects such as doors and door-like cabinets. Next, in order to distinguish intra-class objects (e.g. an office door from a bathroom door), we extract and recognize text information associated with the detected objects. For text recognition, we first extract text regions from signs with multiple colors and possibly complex backgrounds, and then apply character localization and topological analysis to filter out background interference. The extracted text is recognized using off-the-shelf optical character recognition (OCR) software products. The object type, orientation, location, and text information are presented to the blind traveler as speech.

  16. Computer-aided instruction system; Systeme d'enseignement programme par ordinateur

    Energy Technology Data Exchange (ETDEWEB)

    Teneze, Jean Claude

    1968-12-18

    This research thesis addresses the use of teleprocessing and time sharing by the RAX IBM system and the possibility to introduce a dialog with the machine to develop an application in which the computer plays the role of a teacher for different pupils at the same time. Two operating modes are thus exploited: a teacher-mode and a pupil-mode. The developed CAI (computer-aided instruction) system comprises a checker to check the course syntax in teacher-mode, a translator to trans-code the course written in teacher-mode into a form which can be processes by the execution programme, and the execution programme which presents the course in pupil-mode.

  17. Computational Approaches for Analyzing Tradeoffs between Training and Aiding. Final Technical Paper for Period February-December 1989.

    Science.gov (United States)

    Rouse, William B.; Johnson, William B.

    A methodological framework is presented for representing tradeoffs among alternative combinations of training and aiding for personnel in complex situations. In general, more highly trained people need less aid, and those with less training need more aid. Balancing training and aiding to accomplish the objectives of the system in a cost effective…

  18. 9th Asian Conference on Computer-Aided Surgery

    CERN Document Server

    2016-01-01

    This book presents the latest research advances in the theory, design, control, and application of robot systems intended for a variety of purposes such as manipulation, manufacturing, automation, surgery, locomotion, and biomechanics. Several chapters deal with fundamental kinematics in nature, including synthesis, calibration, redundancy, force control, dexterity, inverse and forward kinematics, kinematic singularities, and over-constrained systems. This book is a compilation of the extended versions of the very best papers selected from the many that were presented at the Asian Conference on Computer-Aided Surgery held September 16–18, 2013, in Tokyo, Japan (ACCAS 2013).

  19. Computer-aided design of microvasculature systems for use in vascular scaffold production

    International Nuclear Information System (INIS)

    Mondy, William Lafayette; Cameron, Don; Timmermans, Jean-Pierre; De Clerck, Nora; Sasov, Alexander; Casteleyn, Christophe; Piegl, Les A

    2009-01-01

    In vitro biomedical engineering of intact, functional vascular networks, which include capillary structures, is a prerequisite for adequate vascular scaffold production. Capillary structures are necessary since they provide the elements and compounds for the growth, function and maintenance of 3D tissue structures. Computer-aided modeling of stereolithographic (STL) micro-computer tomographic (micro-CT) 3D models is a technique that enables us to mimic the design of vascular tree systems containing capillary beds, found in tissues. In our first paper (Mondy et al 2009 Tissue Eng. at press), using micro-CT, we studied the possibility of using vascular tissues to produce data capable of aiding the design of vascular tree scaffolding, which would help in the reverse engineering of a complete vascular tree system including capillary bed structures. In this paper, we used STL models of large datasets of computer-aided design (CAD) data of vascular structures which contained capillary structures that mimic those in the dermal layers of rabbit skin. Using CAD software we created from 3D STL models a bio-CAD design for the development of capillary-containing vascular tree scaffolding for skin. This method is designed to enhance a variety of therapeutic protocols including, but not limited to, organ and tissue repair, systemic disease mediation and cell/tissue transplantation therapy. Our successful approach to in vitro vasculogenesis will allow the bioengineering of various other types of 3D tissue structures, and as such greatly expands the potential applications of biomedical engineering technology into the fields of biomedical research and medicine.

  20. Computer-aided design of microvasculature systems for use in vascular scaffold production

    Energy Technology Data Exchange (ETDEWEB)

    Mondy, William Lafayette [Department of Chemical and Biomedical Engineering, University of South Florida, FL (United States); Cameron, Don [Department of Pathology and Cell Biology, College of Medicine, University of South Florida, FL (United States); Timmermans, Jean-Pierre [Department of Veterinary Sciences, University of Antwerp (Belgium); De Clerck, Nora [Department of Biomedical Sciences University of Antwerp (Belgium); Sasov, Alexander [Skyscan (Belgium); Casteleyn, Christophe [College of Veterinary Medicine, Ghent University (Belgium); Piegl, Les A [Department of Computer Science and Engineering, University of South Florida, FL (United States)

    2009-09-15

    In vitro biomedical engineering of intact, functional vascular networks, which include capillary structures, is a prerequisite for adequate vascular scaffold production. Capillary structures are necessary since they provide the elements and compounds for the growth, function and maintenance of 3D tissue structures. Computer-aided modeling of stereolithographic (STL) micro-computer tomographic (micro-CT) 3D models is a technique that enables us to mimic the design of vascular tree systems containing capillary beds, found in tissues. In our first paper (Mondy et al 2009 Tissue Eng. at press), using micro-CT, we studied the possibility of using vascular tissues to produce data capable of aiding the design of vascular tree scaffolding, which would help in the reverse engineering of a complete vascular tree system including capillary bed structures. In this paper, we used STL models of large datasets of computer-aided design (CAD) data of vascular structures which contained capillary structures that mimic those in the dermal layers of rabbit skin. Using CAD software we created from 3D STL models a bio-CAD design for the development of capillary-containing vascular tree scaffolding for skin. This method is designed to enhance a variety of therapeutic protocols including, but not limited to, organ and tissue repair, systemic disease mediation and cell/tissue transplantation therapy. Our successful approach to in vitro vasculogenesis will allow the bioengineering of various other types of 3D tissue structures, and as such greatly expands the potential applications of biomedical engineering technology into the fields of biomedical research and medicine.

  1. Computer-aided design of microvasculature systems for use in vascular scaffold production.

    Science.gov (United States)

    Mondy, William Lafayette; Cameron, Don; Timmermans, Jean-Pierre; De Clerck, Nora; Sasov, Alexander; Casteleyn, Christophe; Piegl, Les A

    2009-09-01

    In vitro biomedical engineering of intact, functional vascular networks, which include capillary structures, is a prerequisite for adequate vascular scaffold production. Capillary structures are necessary since they provide the elements and compounds for the growth, function and maintenance of 3D tissue structures. Computer-aided modeling of stereolithographic (STL) micro-computer tomographic (micro-CT) 3D models is a technique that enables us to mimic the design of vascular tree systems containing capillary beds, found in tissues. In our first paper (Mondy et al 2009 Tissue Eng. at press), using micro-CT, we studied the possibility of using vascular tissues to produce data capable of aiding the design of vascular tree scaffolding, which would help in the reverse engineering of a complete vascular tree system including capillary bed structures. In this paper, we used STL models of large datasets of computer-aided design (CAD) data of vascular structures which contained capillary structures that mimic those in the dermal layers of rabbit skin. Using CAD software we created from 3D STL models a bio-CAD design for the development of capillary-containing vascular tree scaffolding for skin. This method is designed to enhance a variety of therapeutic protocols including, but not limited to, organ and tissue repair, systemic disease mediation and cell/tissue transplantation therapy. Our successful approach to in vitro vasculogenesis will allow the bioengineering of various other types of 3D tissue structures, and as such greatly expands the potential applications of biomedical engineering technology into the fields of biomedical research and medicine.

  2. Computer-aided diagnosis of pneumoconiosis abnormalities extracted from chest radiographs scanned with a CCD scanner

    International Nuclear Information System (INIS)

    Abe, Koji; Minami, Masahide; Nakamura, Munehiro

    2011-01-01

    This paper presents a computer-aided diagnosis for pneumoconiosis radiographs obtained with a common charge-coupled devices (CCD) scanner. Since the current computer-aided diagnosis systems of pneumoconiosis are not practical for medical doctors due to high costs of usage for a special scanner, we propose a novel system which measures abnormalities of pneumoconiosis from lung images obtained with a common CCD scanner. Experimental results of discriminations between normal and abnormal cases for 56 right-lung images including 6 standard pneumoconiosis images have shown that the proposed abnormalities are well extracted according to the standards of pneumoconiosis categories. (author)

  3. Computer Aided Design of Kaplan Turbine Piston with\tSolidWorks

    Directory of Open Access Journals (Sweden)

    Camelia Jianu

    2010-10-01

    Full Text Available The paper presents the steps for 3D computer aided design (CAD of Kaplan turbine piston made in SolidWorks.The present paper is a tutorial for a Kaplan turbine piston 3D geometry, which is dedicaded to the Parts Sketch and Parts Features design and Drawing Geometry and Drawing Annotation.

  4. Influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin.

    Science.gov (United States)

    Poggio, Claudio; Pigozzo, Marco; Ceci, Matteo; Scribante, Andrea; Beltrami, Riccardo; Chiesa, Marco

    2016-01-01

    The purpose of this study was to evaluate the influence of three different luting protocols on shear bond strength of computer aided design/computer aided manufacturing (CAD/CAM) resin nanoceramic (RNC) material to dentin. In this in vitro study, 30 disks were milled from RNC blocks (Lava Ultimate/3M ESPE) with CAD/CAM technology. The disks were subsequently cemented to the exposed dentin of 30 recently extracted bovine permanent mandibular incisors. The specimens were randomly assigned into 3 groups of 10 teeth each. In Group 1, disks were cemented using a total-etch protocol (Scotchbond™ Universal Etchant phosphoric acid + Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 2, disks were cemented using a self-etch protocol (Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 3, disks were cemented using a self-adhesive protocol (RelyX™ Unicem 2 Automix self-adhesive resin cement). All cemented specimens were placed in a universal testing machine (Instron Universal Testing Machine 3343) and submitted to a shear bond strength test to check the strength of adhesion between the two substrates, dentin, and RNC disks. Specimens were stressed at a crosshead speed of 1 mm/min. Data were analyzed with analysis of variance and post-hoc Tukey's test at a level of significance of 0.05. Post-hoc Tukey testing showed that the highest shear strength values (P adhesives) showed better shear strength values compared to self-adhesive resin cements. Furthermore, conventional resin cements used together with a self-etch adhesive reported the highest values of adhesion.

  5. View-based 3-D object retrieval

    CERN Document Server

    Gao, Yue

    2014-01-01

    Content-based 3-D object retrieval has attracted extensive attention recently and has applications in a variety of fields, such as, computer-aided design, tele-medicine,mobile multimedia, virtual reality, and entertainment. The development of efficient and effective content-based 3-D object retrieval techniques has enabled the use of fast 3-D reconstruction and model design. Recent technical progress, such as the development of camera technologies, has made it possible to capture the views of 3-D objects. As a result, view-based 3-D object retrieval has become an essential but challenging res

  6. A Computer-Aided Exercise for Checking Novices' Understanding of Market Equilibrium Changes.

    Science.gov (United States)

    Katz, Arnold

    1999-01-01

    Describes a computer-aided supplement to the introductory microeconomics course that enhances students' understanding with simulation-based tools for reviewing what they have learned from lectures and conventional textbooks about comparing market equilibria. Includes a discussion of students' learning progressions and retention after using the…

  7. Data Management Standards in Computer-aided Acquisition and Logistic Support (CALS)

    Science.gov (United States)

    Jefferson, David K.

    1990-01-01

    Viewgraphs and discussion on data management standards in computer-aided acquisition and logistic support (CALS) are presented. CALS is intended to reduce cost, increase quality, and improve timeliness of weapon system acquisition and support by greatly improving the flow of technical information. The phase 2 standards, industrial environment, are discussed. The information resource dictionary system (IRDS) is described.

  8. Computer-aided dispatch--traffic management center field operational test : Washington State final report

    Science.gov (United States)

    2006-05-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch - Traffic Management Center Integration Field Operations Test in the State of Washington. The document discusses evaluation findings in the foll...

  9. A Computer Aided System for Correlation and Prediction of Phase Equilibrium Data

    DEFF Research Database (Denmark)

    Nielsen, T.L.; Gani, Rafiqul

    2001-01-01

    based on mathematical programming. This paper describes the development of a computer aided system for the systematic derivation of appropriate property models to be used in the service role for a specified problem. As a first step, a library of well-known property models ha's been developed...

  10. Computer aided design of nickel-base superalloys

    International Nuclear Information System (INIS)

    Lawrence, P.J.

    1988-01-01

    This paper describes a computer aided design process for Ni-base superalloys developed and employed at ASEA Brown Boveri. The technique involves a series of modules each of which predicts a particular property of a hypothetical new composition. In the first stage of the development of this design techniques modules were produced to predict phase stability, using PHACOMP, and high temperature creep strength and hot corrosion resistance, using multiple linear regression equations derived from the data in the literature. Alloys designed using these technique are also discussed and, in particular, shortcomings of the design process are highlighted. This information was then used to produce a revamped design methodology involving extra modules, including prediction of an alloy's gamma-prime content. (orig.)

  11. Implementing version support for complex objects

    OpenAIRE

    Blanken, Henk

    1991-01-01

    New applications in the area of office information systems, computer aided design and manufacturing make new demands upon database management systems. Among others highly structured objects and their history have to be represented and manipulated. The paper discusses some general problems concerning the access and storage of complex objects with their versions and the solutions developed within the AIM/II project. Queries related to versions are distinguished in ASOF queries (asking informati...

  12. Computer-aided Molecular Design of Compounds Targeting Histone Modifying Enzymes

    Science.gov (United States)

    Andreoli, Federico; Del Rio, Alberto

    2015-01-01

    Growing evidences show that epigenetic mechanisms play crucial roles in the genesis and progression of many physiopathological processes. As a result, research in epigenetic grew at a fast pace in the last decade. In particular, the study of histone post-translational modifications encountered an extraordinary progression and many modifications have been characterized and associated to fundamental biological processes and pathological conditions. Histone modifications are the catalytic result of a large set of enzyme families that operate covalent modifications on specific residues at the histone tails. Taken together, these modifications elicit a complex and concerted processing that greatly contribute to the chromatin remodeling and may drive different pathological conditions, especially cancer. For this reason, several epigenetic targets are currently under validation for drug discovery purposes and different academic and industrial programs have been already launched to produce the first pre-clinical and clinical outcomes. In this scenario, computer-aided molecular design techniques are offering important tools, mainly as a consequence of the increasing structural information available for these targets. In this mini-review we will briefly discuss the most common types of known histone modifications and the corresponding operating enzymes by emphasizing the computer-aided molecular design approaches that can be of use to speed-up the efforts to generate new pharmaceutically relevant compounds. PMID:26082827

  13. Computer-aided analysis of cutting processes for brittle materials

    Science.gov (United States)

    Ogorodnikov, A. I.; Tikhonov, I. N.

    2017-12-01

    This paper is focused on 3D computer simulation of cutting processes for brittle materials and silicon wafers. Computer-aided analysis of wafer scribing and dicing is carried out with the use of the ANSYS CAE (computer-aided engineering) software, and a parametric model of the processes is created by means of the internal ANSYS APDL programming language. Different types of tool tip geometry are analyzed to obtain internal stresses, such as a four-sided pyramid with an included angle of 120° and a tool inclination angle to the normal axis of 15°. The quality of the workpieces after cutting is studied by optical microscopy to verify the FE (finite-element) model. The disruption of the material structure during scribing occurs near the scratch and propagates into the wafer or over its surface at a short range. The deformation area along the scratch looks like a ragged band, but the stress width is rather low. The theory of cutting brittle semiconductor and optical materials is developed on the basis of the advanced theory of metal turning. The fall of stress intensity along the normal on the way from the tip point to the scribe line can be predicted using the developed theory and with the verified FE model. The crystal quality and dimensions of defects are determined by the mechanics of scratching, which depends on the shape of the diamond tip, the scratching direction, the velocity of the cutting tool and applied force loads. The disunity is a rate-sensitive process, and it depends on the cutting thickness. The application of numerical techniques, such as FE analysis, to cutting problems enhances understanding and promotes the further development of existing machining technologies.

  14. Creating an Electronic Reference and Information Database for Computer-aided ECM Design

    Science.gov (United States)

    Nekhoroshev, M. V.; Pronichev, N. D.; Smirnov, G. V.

    2018-01-01

    The paper presents a review on electrochemical shaping. An algorithm has been developed to implement a computer shaping model applicable to pulse electrochemical machining. For that purpose, the characteristics of pulse current occurring in electrochemical machining of aviation materials have been studied. Based on integrating the experimental results and comprehensive electrochemical machining process data modeling, a subsystem for computer-aided design of electrochemical machining for gas turbine engine blades has been developed; the subsystem was implemented in the Teamcenter PLM system.

  15. APPLICATION OF COMPUTER AIDED TOMOGRAPHY (CAT) TO THE STUDY OF MARINE BENTIC COMMUNITIES

    Science.gov (United States)

    Sediment cores were imaged using a Computer-Aided Tomography (CT) scanner at Massachusetts General Hospital, Boston, Massachusetts, United States. Procedures were developed, using the attenuation of X-rays, to differentiate between sediment and the water contained in macrobenthic...

  16. Development of computer-aided design system of elastic sensitive elements of automatic metering devices

    Science.gov (United States)

    Kalinkina, M. E.; Kozlov, A. S.; Labkovskaia, R. I.; Pirozhnikova, O. I.; Tkalich, V. L.; Shmakov, N. A.

    2018-05-01

    The object of research is the element base of devices of control and automation systems, including in its composition annular elastic sensitive elements, methods of their modeling, calculation algorithms and software complexes for automation of their design processes. The article is devoted to the development of the computer-aided design system of elastic sensitive elements used in weight- and force-measuring automation devices. Based on the mathematical modeling of deformation processes in a solid, as well as the results of static and dynamic analysis, the calculation of elastic elements is given using the capabilities of modern software systems based on numerical simulation. In the course of the simulation, the model was a divided hexagonal grid of finite elements with a maximum size not exceeding 2.5 mm. The results of modal and dynamic analysis are presented in this article.

  17. Computer-aided diagnosis and volumetry of pulmonary nodules: current concepts and future perspectives

    International Nuclear Information System (INIS)

    Marten, K.; Rummeny, E.J.; Engelke, C.

    2005-01-01

    For computer-aided detection (CAD) and volumetry of small pulmonary nodules, a number of algorithms have been developed for multislice CT data sets in recent years, with the goal of improving the diagnostic work-up and the follow-up of findings. Recent data show that the detection of small lesions may improve with CAD, suggesting that especially experienced readers may benefit from using CAD systems. This has lead to the recommendation of CAD as a replacement of the second reader in clinical practice. Furthermore, computer-aided volumetry of pulmonary nodules allows a precise determination of nodular growth rates as a prerequisite for a better classification of nodules as benign or malignant. In this article, we review recent developments of CAD and volumetry tools for pulmonary nodules, and address open questions regarding the use of these software tools in clinical routine. (orig.)

  18. Observer training for computer-aided detection of pulmonary nodules in chest radiography

    NARCIS (Netherlands)

    de Boo, Diederick W.; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J.; Freling, Nicole J.; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M.

    2012-01-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a

  19. Computer-aided design for metabolic engineering.

    Science.gov (United States)

    Fernández-Castané, Alfred; Fehér, Tamás; Carbonell, Pablo; Pauthenier, Cyrille; Faulon, Jean-Loup

    2014-12-20

    The development and application of biotechnology-based strategies has had a great socio-economical impact and is likely to play a crucial role in the foundation of more sustainable and efficient industrial processes. Within biotechnology, metabolic engineering aims at the directed improvement of cellular properties, often with the goal of synthesizing a target chemical compound. The use of computer-aided design (CAD) tools, along with the continuously emerging advanced genetic engineering techniques have allowed metabolic engineering to broaden and streamline the process of heterologous compound-production. In this work, we review the CAD tools available for metabolic engineering with an emphasis, on retrosynthesis methodologies. Recent advances in genetic engineering strategies for pathway implementation and optimization are also reviewed as well as a range of bionalytical tools to validate in silico predictions. A case study applying retrosynthesis is presented as an experimental verification of the output from Retropath, the first complete automated computational pipeline applicable to metabolic engineering. Applying this CAD pipeline, together with genetic reassembly and optimization of culture conditions led to improved production of the plant flavonoid pinocembrin. Coupling CAD tools with advanced genetic engineering strategies and bioprocess optimization is crucial for enhanced product yields and will be of great value for the development of non-natural products through sustainable biotechnological processes. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Fracture resistance of computer-aided design and computer-aided manufacturing ceramic crowns cemented on solid abutments.

    Science.gov (United States)

    Stona, Deborah; Burnett, Luiz Henrique; Mota, Eduardo Gonçalves; Spohr, Ana Maria

    2015-07-01

    Because no information was found in the dental literature regarding the fracture resistance of all-ceramic crowns using CEREC (Sirona) computer-aided design and computer-aided manufacturing (CAD-CAM) system on solid abutments, the authors conducted a study. Sixty synOcta (Straumann) implant replicas and regular neck solid abutments were embedded in acrylic resin and randomly assigned (n = 20 per group). Three types of ceramics were used: feldspathic, CEREC VITABLOCS Mark II (VITA); leucite, IPS Empress CAD (Ivoclar Vivadent); and lithium disilicate, IPS e.max CAD (Ivoclar Vivadent). The crowns were fabricated by the CEREC CAD-CAM system. After receiving glaze, the crowns were cemented with RelyX U200 (3M ESPE) resin cement under load of 1 kilogram. For each ceramic, one-half of the specimens were subjected to the fracture resistance testing in a universal testing machine with a crosshead speed of 1 millimeter per minute, and the other half were subjected to the fractured resistance testing after 1,000,000 cyclic fatigue loading at 100 newtons. According to a 2-way analysis of variance, the interaction between the material and mechanical cycling was significant (P = .0001). According to a Tukey test (α = .05), the fracture resistance findings with or without cyclic fatigue loading were as follows, respectively: CEREC VITABLOCKS Mark II (405 N/454 N) was statistically lower than IPS Empress CAD (1169 N/1240 N) and IPS e.max CAD (1378 N/1025 N) (P Empress CAD and IPS e.max CAD did not differ statistically (P > .05). According to a t test, there was no statistical difference in the fracture resistance with and without cyclic fatigue loading for CEREC VITABLOCS Mark II and IPS Empress CAD (P > .05). For IPS e.max CAD, the fracture resistance without cyclic fatigue loading was statistically superior to that obtained with cyclic fatigue loading (P Empress CAD and IPS e.max CAD showed higher fracture resistance compared with CEREC VITABLOCS Mark II. The cyclic

  1. The classification and evaluation of Computer-Aided Software Engineering tools

    OpenAIRE

    Manley, Gary W.

    1990-01-01

    Approved for public release; distribution unlimited. The use of Computer-Aided Software Engineering (CASE) tools has been viewed as a remedy for the software development crisis by achieving improved productivity and system quality via the automation of all or part of the software engineering process. The proliferation and tremendous variety of tools available have stretched the understanding of experienced practitioners and has had a profound impact on the software engineering process itse...

  2. Computer-aided topological analysis of Nd-Fe-B ternary system

    International Nuclear Information System (INIS)

    Liu, G.; Xu, P.; Zhang, W.

    1993-01-01

    A three-dimensional partially matrixed topological model of the Nd-Fe-B ternary phase diagram has been established based on experimental results assessed comprehensively with the aid of a computer-aided design and graphic and graphics software, AutoCAD (R10), and application programs developed in this work. Vertical sections at 5.88 at.% B, Nd:B = 1:1, Fe-Nd/sub 2/Fe/sub 14/B-Nd, Nd/sub 2/Fe/sub 17/-Nd/sub 2/Fe/sub 7/B/sub 6/ have been cut out from the model and the corresponding phase relationships have been analyzed. Among them, those on the Nd-rich protons of both the sections at 5.88 at.% B and Nd:B = 2:1 and those on the Nd/sub 2/Fe/sub 14/B-Nd section are given for the first time. (author)

  3. Computer Aided Design of a Low-Cost Painting Robot

    Directory of Open Access Journals (Sweden)

    SYEDA MARIA KHATOON ZAIDI

    2017-10-01

    Full Text Available The application of robots or robotic systems for painting parts is becoming increasingly conventional; to improve reliability, productivity, consistency and to decrease waste. However, in Pakistan only highend Industries are able to afford the luxury of a robotic system for various purposes. In this study we propose an economical Painting Robot that a small-scale industry can install in their plant with ease. The importance of this robot is that being cost effective, it can easily be replaced in small manufacturing industries and therefore, eliminate health problems occurring to the individual in charge of painting parts on an everyday basis. To achieve this aim, the robot is made with local parts with only few exceptions, to cut costs; and the programming language is kept at a mediocre level. Image processing is used to establish object recognition and it can be programmed to paint various simple geometries. The robot is placed on a conveyer belt to maximize productivity. A four DoF (Degree of Freedom arm increases the working envelope and accessibility of painting different shaped parts with ease. This robot is capable of painting up, front, back, left and right sides of the part with a single colour. Initially CAD (Computer Aided Design models of the robot were developed which were analyzed, modified and improved to withstand loading condition and perform its task efficiently. After design selection, appropriate motors and materials were selected and the robot was developed. Throughout the development phase, minor problems and errors were fixed accordingly as they arose. Lastly the robot was integrated with the computer and image processing for autonomous control. The final results demonstrated that the robot is economical and reduces paint wastage.

  4. Computer aided design of a low-cost painting robot

    International Nuclear Information System (INIS)

    Zaidi, S.M.; Janejo, F.; Mujtaba, S.B.

    2017-01-01

    The application of robots or robotic systems for painting parts is becoming increasingly conventional; to improve reliability, productivity, consistency and to decrease waste. However, in Pakistan only highend Industries are able to afford the luxury of a robotic system for various purposes. In this study we propose an economical Painting Robot that a small-scale industry can install in their plant with ease. The importance of this robot is that being cost effective, it can easily be replaced in small manufacturing industries and therefore, eliminate health problems occurring to the individual in charge of painting parts on an everyday basis. To achieve this aim, the robot is made with local parts with only few exceptions, to cut costs; and the programming language is kept at a mediocre level. Image processing is used to establish object recognition and it can be programmed to paint various simple geometries. The robot is placed on a conveyer belt to maximize productivity. A four DoF (Degree of Freedom) arm increases the working envelope and accessibility of painting different shaped parts with ease. This robot is capable of painting up, front, back, left and right sides of the part with a single colour. Initially CAD (Computer Aided Design) models of the robot were developed which were analyzed, modified and improved to withstand loading condition and perform its task efficiently. After design selection, appropriate motors and materials were selected and the robot was developed. Throughout the development phase, minor problems and errors were fixed accordingly as they arose. Lastly the robot was integrated with the computer and image processing for autonomous control. The final results demonstrated that the robot is economical and reduces paint wastage. (author)

  5. A computer - aided system for the the E.D.F. 1400 MW. Nuclear power plants control

    International Nuclear Information System (INIS)

    Beltranda, G.; Philipps, C.

    1988-01-01

    The future E.D.F. 1400 MW nuclear power plants (due to be commissioned in 1991 at CHOOZ) are provided with a control and instrumentation system including the following levels: - sensors and actuators (LEVEL 0): this is the interface of the elementary acquisition and control signals; - the programmable logical and numerical controllers (LEVEL 1) for the logical control sequences and analog adjustment sequences for the whole equipment of the facilities; - the control room (LEVEL 2) including the computer-aided operation system as well as the wall mimic diagram and the auxiliary panel directly connected to the controllers. This is the processing and control conversational level; - the maintenance and site computer-aided systems (LEVEL 3). This paper aims at describing the computer-aided operation system (called KIC N4), its main functions, its architecture and the solutions retained as regards its softwares and the high-quality of data required. The achievement of this system has been entrusted by EDF to the SEMA. METRA/CIMSA-SINTRA grouping, among which SEMA.METRA is the leading company

  6. Computer Aided Diagnosis for Confocal Laser Endomicroscopy in Advanced Colorectal Adenocarcinoma.

    Directory of Open Access Journals (Sweden)

    Daniela Ştefănescu

    Full Text Available Confocal laser endomicroscopy (CLE is becoming a popular method for optical biopsy of digestive mucosa for both diagnostic and therapeutic procedures. Computer aided diagnosis of CLE images, using image processing and fractal analysis can be used to quantify the histological structures in the CLE generated images. The aim of this study is to develop an automatic diagnosis algorithm of colorectal cancer (CRC, based on fractal analysis and neural network modeling of the CLE-generated colon mucosa images.We retrospectively analyzed a series of 1035 artifact-free endomicroscopy images, obtained during CLE examinations from normal mucosa (356 images and tumor regions (679 images. The images were processed using a computer aided diagnosis (CAD medical imaging system in order to obtain an automatic diagnosis. The CAD application includes image reading and processing functions, a module for fractal analysis, grey-level co-occurrence matrix (GLCM computation module, and a feature identification module based on the Marching Squares and linear interpolation methods. A two-layer neural network was trained to automatically interpret the imaging data and diagnose the pathological samples based on the fractal dimension and the characteristic features of the biological tissues.Normal colon mucosa is characterized by regular polyhedral crypt structures whereas malignant colon mucosa is characterized by irregular and interrupted crypts, which can be diagnosed by CAD. For this purpose, seven geometric parameters were defined for each image: fractal dimension, lacunarity, contrast correlation, energy, homogeneity, and feature number. Of the seven parameters only contrast, homogeneity and feature number were significantly different between normal and cancer samples. Next, a two-layer feed forward neural network was used to train and automatically diagnose the malignant samples, based on the seven parameters tested. The neural network operations were cross

  7. Computer aided process planning at the Oak Ridge Y-12 plant: a pilot project

    International Nuclear Information System (INIS)

    Hewgley, R.E. Jr.; Prewett, H.P. Jr.

    1979-01-01

    In 1976, a formal needs analysis was conducted in one of the Fabrication Division Shops of all activities from the receipt of an order through final machining. The results indicated deficiencies in process planning activities involving special production work. A pilot program was organized to investigate the benefits of emerging CAM technology and application of GT concepts for machining operations at the Y-12 Plant. The objective of the CAPP Project was to provide computer-assisted process planning for special production machining in th shop. The CAPP team was charged with the specific goal of demonstrating computer-aided process planning within a four-year term. The CAPP charter included a plan with intermediate measurable milestones for achieving its mission. In three years, the CAPP project demonstrated benefits to process planning. A capability to retrieve historical records for similar parts, to review accurately the status of all staff assignments, and to generate detailed machining procedures definitely can impact the way in which a machine shop prepared for new orders. The real payoff is in the hardcopy output (N/C programs, studies, sequence plans, and procedures). 4 figures,

  8. Gathering Empirical Evidence Concerning Links between Computer Aided Design (CAD) and Creativity

    Science.gov (United States)

    Musta'amal, Aede Hatib; Norman, Eddie; Hodgson, Tony

    2009-01-01

    Discussion is often reported concerning potential links between computer-aided designing and creativity, but there is a lack of systematic enquiry to gather empirical evidence concerning such links. This paper reports an indication of findings from other research studies carried out in contexts beyond general education that have sought evidence…

  9. Development of a Computer-aided Learning System for Graphical Analysis of Continuous-Time Control Systems

    Directory of Open Access Journals (Sweden)

    J. F. Opadiji

    2010-06-01

    Full Text Available We present the development and deployment process of a computer-aided learning tool which serves as a training aid for undergraduate control engineering courses. We show the process of algorithm construction and implementation of the software which is also aimed at teaching software development at undergraduate level. The scope of this project is limited to graphical analysis of continuous-time control systems.

  10. Computer-Aided Drug Discovery in Plant Pathology.

    Science.gov (United States)

    Shanmugam, Gnanendra; Jeon, Junhyun

    2017-12-01

    Control of plant diseases is largely dependent on use of agrochemicals. However, there are widening gaps between our knowledge on plant diseases gained from genetic/mechanistic studies and rapid translation of the knowledge into target-oriented development of effective agrochemicals. Here we propose that the time is ripe for computer-aided drug discovery/design (CADD) in molecular plant pathology. CADD has played a pivotal role in development of medically important molecules over the last three decades. Now, explosive increase in information on genome sequences and three dimensional structures of biological molecules, in combination with advances in computational and informational technologies, opens up exciting possibilities for application of CADD in discovery and development of agrochemicals. In this review, we outline two categories of the drug discovery strategies: structure- and ligand-based CADD, and relevant computational approaches that are being employed in modern drug discovery. In order to help readers to dive into CADD, we explain concepts of homology modelling, molecular docking, virtual screening, and de novo ligand design in structure-based CADD, and pharmacophore modelling, ligand-based virtual screening, quantitative structure activity relationship modelling and de novo ligand design for ligand-based CADD. We also provide the important resources available to carry out CADD. Finally, we present a case study showing how CADD approach can be implemented in reality for identification of potent chemical compounds against the important plant pathogens, Pseudomonas syringae and Colletotrichum gloeosporioides .

  11. Multi-objective optimization in computer networks using metaheuristics

    CERN Document Server

    Donoso, Yezid

    2007-01-01

    Metaheuristics are widely used to solve important practical combinatorial optimization problems. Many new multicast applications emerging from the Internet-such as TV over the Internet, radio over the Internet, and multipoint video streaming-require reduced bandwidth consumption, end-to-end delay, and packet loss ratio. It is necessary to design and to provide for these kinds of applications as well as for those resources necessary for functionality. Multi-Objective Optimization in Computer Networks Using Metaheuristics provides a solution to the multi-objective problem in routing computer networks. It analyzes layer 3 (IP), layer 2 (MPLS), and layer 1 (GMPLS and wireless functions). In particular, it assesses basic optimization concepts, as well as several techniques and algorithms for the search of minimals; examines the basic multi-objective optimization concepts and the way to solve them through traditional techniques and through several metaheuristics; and demonstrates how to analytically model the compu...

  12. A Computer-Aided Diagnosis for Evaluating Lung Nodules on Chest CT: the Current Status and Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Jin Mo [Seoul National University Medical Research Center, Seoul (Korea, Republic of)

    2011-04-15

    As the detection and characterization of lung nodules are of paramount importance in thoracic radiology, various tools for making a computer-aided diagnosis (CAD) have been developed to improve the diagnostic performance of radiologists in clinical practice. Numerous studies over the years have shown that the CAD system can effectively help readers identify more nodules. Moreover, nodule malignancy and the response of malignant lung tumors to treatment can also be assessed using nodule volumetry. CAD also has the potential to objectively analyze the morphology of nodules and enhance the work flow during the assessment of follow-up studies. Therefore, understanding the current status and limitations of CAD for evaluating lung nodules is essential to effectively apply CAD in clinical practice

  13. Realization of multi-parameter and multi-state in fault tree computer-aided building software

    International Nuclear Information System (INIS)

    Guo Xiaoli; Tong Jiejuan; Xue Dazhi

    2004-01-01

    More than one parameter and more than one failed state of a parameter are often involved in building fault tree, so it is necessary for fault tree computer-aided building software to deal with multi-parameter and multi-state. Fault Tree Expert System (FTES) has the target of aiding the FT-building work of hydraulic systems. This paper expatiates on how to realize multi-parameter and multi-state in FTES with focus on Knowledge Base and Illation Engine. (author)

  14. Effect of Premolar Axial Wall Height on Computer-Aided Design/Computer-Assisted Manufacture Crown Retention.

    Science.gov (United States)

    Martin, Curt; Harris, Ashley; DuVall, Nicholas; Wajdowicz, Michael; Roberts, Howard Wayne

    2018-03-28

    To evaluate the effect of premolar axial wall height on the retention of adhesive, full-coverage, computer-aided design/computer-assisted manufacture (CAD/CAM) restorations. A total of 48 premolar teeth randomized into four groups (n = 12 per group) received all-ceramic CAD/CAM restorations with axial wall heights (AWH) of 3, 2, 1, and 0 mm and 16-degree total occlusal convergence (TOC). Specimens were restored with lithium disilicate material and cemented with self-adhesive resin cement. Specimens were loaded to failure after 24 hours. The 3- and 2-mm AWH specimens demonstrated significantly greater failure load. Failure analysis suggests a 2-mm minimum AWH for premolars with a TOC of 16 degrees. Adhesive technology may compensate for compromised AWH.

  15. Chawton Novels Online, Women’s Writing 1751-1834 and Computer-Aided Textual Analysis

    Directory of Open Access Journals (Sweden)

    Anne Bandry-Scubbi

    2015-10-01

    Full Text Available Using Chawton House Library’s “Novels Online,” several corpora have been set up for a computer-aided textual analysis of the use of vocabulary by women writing “domestic novels” from 1752 to 1834. This corpus stylistics approach makes it possible to map texts according to their word usage and to identify quantitative keywords which provide vocabulary profiles through comparison and contrast with contemporary male and female canonical texts. Items identified include pronouns, markers of dialogue and of intensity; others can be grouped into specific lexical fields such as feelings. One text from the collection then forms the object of a case-study to explore a paradox: although Jane Taylor’s use of vocabulary in her 1817 Rachel appears the most representative of the corpus made up of 42 novels by women, this Chawton text has been called “a highly original tale.” Methodology and findings are both presented to address the challenge of identifying features which constitute typicality.

  16. BNFL's application of computer aided engineering to 'THORP' thermal oxide reprocessing plant

    International Nuclear Information System (INIS)

    Hall-Wilton, M.J.

    1990-01-01

    BNFL are currently constructing facilities at Sellafield, Cumbria to reprocess thermal oxide fuel for U.K., European and Japanese utilities. Faced with a 3.5bn pound capital program to provide new facilities at Sellafield, BNFL took the opportunity to embrace the new computer aided engineering technologies then emerging in 1981. To give some idea of the commitment made by BNFL to the above many millions of pounds has been invested in hardware, and more on software and people. The 'THORP' (Head End and Chemical Separation Plant) project represents 1.5bn pounds. The introduction of computer aided engineering has provided a clash free design with full assurance that all materials and components used are compatible. Planning in the design offices in conjunction with an experienced construction management team enables the sequence of piping installation to be determined long before the construction teams enter the work area. This planning aspect has been significantly improved by using EVS (Enhanced Visualisation System). The use of supercomputing graphics facilities is stimulating demands from areas of engineering who have previously not sought to use magnetic data from a variety of sources. The result is mainly due to the data being easily accessible to users who have very little computing experience. (N.K.)

  17. Visual-Spatial Attention Aids the Maintenance of Object Representations in Visual Working Memory

    Science.gov (United States)

    Williams, Melonie; Pouget, Pierre; Boucher, Leanne; Woodman, Geoffrey F.

    2013-01-01

    Theories have proposed that the maintenance of object representations in visual working memory is aided by a spatial rehearsal mechanism. In this study, we used two different approaches to test the hypothesis that overt and covert visual-spatial attention mechanisms contribute to the maintenance of object representations in visual working memory. First, we tracked observers’ eye movements while remembering a variable number of objects during change-detection tasks. We observed that during the blank retention interval, participants spontaneously shifted gaze to the locations that the objects had occupied in the memory array. Next, we hypothesized that if attention mechanisms contribute to the maintenance of object representations, then drawing attention away from the object locations during the retention interval would impair object memory during these change-detection tasks. Supporting this prediction, we found that attending to the fixation point in anticipation of a brief probe stimulus during the retention interval reduced change-detection accuracy even on the trials in which no probe occurred. These findings support models of working memory in which visual-spatial selection mechanisms contribute to the maintenance of object representations. PMID:23371773

  18. Modeling electric fields in two dimensions using computer aided design

    International Nuclear Information System (INIS)

    Gilmore, D.W.; Giovanetti, D.

    1992-01-01

    The authors describe a method for analyzing static electric fields in two dimensions using AutoCAD. The algorithm is coded in LISP and is modeled after Coloumb's Law. The software platform allows for facile graphical manipulations of field renderings and supports a wide range of hardcopy-output and data-storage formats. More generally, this application is representative of the ability to analyze data that is the solution to known mathematical functions with computer aided design (CAD)

  19. APPLICATION OF INFORMATION AND COMMUNICATION TECHNOLOGIES IN COMPUTER AIDED LANGUAGE LEARNING

    Directory of Open Access Journals (Sweden)

    I. B. Tampel

    2013-01-01

    Full Text Available The article deals with the various ways of application for automatic speech recognition, Text-to-Speech technology, pronunciation and communication skills training, vocabulary check of the taught person, audition skills training in computer aided language learning (CALL-system. In spite of some constraints such technologies application is effective both for education problems simplification and for comfort growth of the system application.

  20. Image formation simulation for computer-aided inspection planning of machine vision systems

    Science.gov (United States)

    Irgenfried, Stephan; Bergmann, Stephan; Mohammadikaji, Mahsa; Beyerer, Jürgen; Dachsbacher, Carsten; Wörn, Heinz

    2017-06-01

    In this work, a simulation toolset for Computer Aided Inspection Planning (CAIP) of systems for automated optical inspection (AOI) is presented along with a versatile two-robot-setup for verification of simulation and system planning results. The toolset helps to narrow down the large design space of optical inspection systems in interaction with a system expert. The image formation taking place in optical inspection systems is simulated using GPU-based real time graphics and high quality off-line-rendering. The simulation pipeline allows a stepwise optimization of the system, from fast evaluation of surface patch visibility based on real time graphics up to evaluation of image processing results based on off-line global illumination calculation. A focus of this work is on the dependency of simulation quality on measuring, modeling and parameterizing the optical surface properties of the object to be inspected. The applicability to real world problems is demonstrated by taking the example of planning a 3D laser scanner application. Qualitative and quantitative comparison results of synthetic and real images are presented.

  1. Contrast enhanced ultrasound in the assessment of urogenital pathology

    Directory of Open Access Journals (Sweden)

    Libero Barozzi

    2014-12-01

    Full Text Available Contrast enhanced ultrasound (CEUS is an innovative technique that employs microbubble contrast agents to demonstrate parenchymal perfusion. Although initial clinical application was focused on the liver pathology, a wide variety of clinical conditions can be assessed now with CEUS. CEUS is a well-tolerated technique and is acquiring an increasing role in the assessment of renal pathology because contrast agents are not excreted by the kidney and do not affect the renal function. CEUS demonstrated an accuracy similar to contrast enhanced multi-detector computed tomography (CEMDCT in detecting focal lesions, with the advantage of the real-time assessment of microvascular perfusion by using time-intensity curves. The aim of this paper is to review the main indications of CEUS in the assessment of renal and urogenital pathology. Imaging examples are presented and described. Advantages and limitations of CEUS with reference to conventional US and CE-MDCT are discussed.

  2. Computer Application Of Object Oriented Database Management ...

    African Journals Online (AJOL)

    Object Oriented Systems (OOS) have been widely adopted in software engineering because of their superiority with respect to data extensibility. The present trend in the software engineering process (SEP) towards concurrent computing raises novel concerns for the facilities and technology available in database ...

  3. Computer-aided Detection Fidelity of Pulmonary Nodules in Chest Radiograph

    Directory of Open Access Journals (Sweden)

    Nikolaos Dellios

    2017-01-01

    Full Text Available Aim: The most ubiquitous chest diagnostic method is the chest radiograph. A common radiographic finding, quite often incidental, is the nodular pulmonary lesion. The detection of small lesions out of complex parenchymal structure is a daily clinical challenge. In this study, we investigate the efficacy of the computer-aided detection (CAD software package SoftView™ 2.4A for bone suppression and OnGuard™ 5.2 (Riverain Technologies, Miamisburg, OH, USA for automated detection of pulmonary nodules in chest radiographs. Subjects and Methods: We retrospectively evaluated a dataset of 100 posteroanterior chest radiographs with pulmonary nodular lesions ranging from 5 to 85 mm. All nodules were confirmed with a consecutive computed tomography scan and histologically classified as 75% malignant. The number of detected lesions by observation in unprocessed images was compared to the number and dignity of CAD-detected lesions in bone-suppressed images (BSIs. Results: SoftView™ BSI does not affect the objective lesion-to-background contrast. OnGuard™ has a stand-alone sensitivity of 62% and specificity of 58% for nodular lesion detection in chest radiographs. The false positive rate is 0.88/image and the false negative (FN rate is 0.35/image. From the true positive lesions, 20% were proven benign and 80% were malignant. FN lesions were 47% benign and 53% malignant. Conclusion: We conclude that CAD does not qualify for a stand-alone standard of diagnosis. The use of CAD accompanied with a critical radiological assessment of the software suggested pattern appears more realistic. Accordingly, it is essential to focus on studies assessing the quality-time-cost profile of real-time (as opposed to retrospective CAD implementation in clinical diagnostics.

  4. Computer-Aided System of Virtual Testing of Gas Turbine Engines

    Directory of Open Access Journals (Sweden)

    Rybakov Viktor N.

    2016-01-01

    Full Text Available The article describes the concept of a virtual lab that includes subsystem of gas turbine engine simulation, subsystem of experiment planning, subsystem of measurement errors simulation, subsystem of simulator identification and others. The basis for virtual lab development is the computer-aided system of thermogasdynamic research and analysis “ASTRA”. The features of gas turbine engine transient modes simulator are described. The principal difference between the simulators of transient and stationary modes of gas turbine engines is that the energy balance of the compressor and turbine becomes not applicable. The computer-aided system of virtual gas turbine engine testing was created using the developed transient modes simulator. This system solves the tasks of operational (throttling, speed, climatic, altitude characteristics calculation, analysis of transient dynamics and selection of optimal control laws. Besides, the system of virtual gas turbine engine testing is a clear demonstration of gas turbine engine working process and the regularities of engine elements collaboration. The interface of the system of virtual gas turbine engine testing is described in the article and some screenshots of the interface elements are provided. The developed system of virtual gas turbine engine testing provides means for reducing the laboriousness of gas turbine engines testing. Besides, the implementation of this system in the learning process allows the diversification of lab works and therefore improve the quality of training.

  5. SINCRO/CAR: An interactive numerical system for computer-aided control engineering and maintenance

    International Nuclear Information System (INIS)

    Zwingelstein, G.; Despujols, A.

    1986-01-01

    This presentation describes a dialogue-oriented software implemented on a portable computer for computer-aided engineering and training in control instrumentation and also for on-line verification of the performances of the analog controllers installed on power plants. The SINCRO/CAR software includes algorithms for controller design, simulation, identification, optimization, frequency response and real time data acquisition. Various results obtained on fossil-fired and nuclear plants are given to illustrate the efficiency of the SINCRO/CAR software

  6. Computer-aided classification of forest cover types from small scale aerial photography

    Science.gov (United States)

    Bliss, John C.; Bonnicksen, Thomas M.; Mace, Thomas H.

    1980-11-01

    The US National Park Service must map forest cover types over extensive areas in order to fulfill its goal of maintaining or reconstructing presettlement vegetation within national parks and monuments. Furthermore, such cover type maps must be updated on a regular basis to document vegetation changes. Computer-aided classification of small scale aerial photography is a promising technique for generating forest cover type maps efficiently and inexpensively. In this study, seven cover types were classified with an overall accuracy of 62 percent from a reproduction of a 1∶120,000 color infrared transparency of a conifer-hardwood forest. The results were encouraging, given the degraded quality of the photograph and the fact that features were not centered, as well as the lack of information on lens vignetting characteristics to make corrections. Suggestions are made for resolving these problems in future research and applications. In addition, it is hypothesized that the overall accuracy is artificially low because the computer-aided classification more accurately portrayed the intermixing of cover types than the hand-drawn maps to which it was compared.

  7. Transmitted wavefront testing with large dynamic range based on computer-aided deflectometry

    Science.gov (United States)

    Wang, Daodang; Xu, Ping; Gong, Zhidong; Xie, Zhongmin; Liang, Rongguang; Xu, Xinke; Kong, Ming; Zhao, Jun

    2018-06-01

    The transmitted wavefront testing technique is demanded for the performance evaluation of transmission optics and transparent glass, in which the achievable dynamic range is a key issue. A computer-aided deflectometric testing method with fringe projection is proposed for the accurate testing of transmitted wavefronts with a large dynamic range. Ray tracing of the modeled testing system is carried out to achieve the virtual ‘null’ testing of transmitted wavefront aberrations. The ray aberration is obtained from the ray tracing result and measured slope, with which the test wavefront aberration can be reconstructed. To eliminate testing system modeling errors, a system geometry calibration based on computer-aided reverse optimization is applied to realize accurate testing. Both numerical simulation and experiments have been carried out to demonstrate the feasibility and high accuracy of the proposed testing method. The proposed testing method can achieve a large dynamic range compared with the interferometric method, providing a simple, low-cost and accurate way for the testing of transmitted wavefronts from various kinds of optics and a large amount of industrial transmission elements.

  8. 13th International Conference on Computer Aided Engineering

    CERN Document Server

    Pietrusiak, Damian

    2017-01-01

    These proceedings of the 13th International Conference on Computer Aided Engineering present selected papers from the event, which was held in Polanica Zdrój, Poland, from June 22 to 25, 2016. The contributions are organized according to thematic sections on the design and manufacture of machines and technical systems; durability prediction; repairs and retrofitting of power equipment; strength and thermodynamic analyses for power equipment; design and calculation of various types of load-carrying structures; numerical methods for dimensioning materials handling; and long-distance transport equipment. The conference and its proceedings offer a major interdisciplinary forum for researchers and engineers to present the most innovative studies and advances in this dynamic field.

  9. Computer-aided dispatch--traffic management center field operational test : state of Utah final report

    Science.gov (United States)

    2006-07-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch Traffic Management Center Integration Field Operations Test in the State of Utah. The document discusses evaluation findings in the followin...

  10. 3D Computer aided treatment planning in endodontics.

    Science.gov (United States)

    van der Meer, Wicher J; Vissink, Arjan; Ng, Yuan Ling; Gulabivala, Kishor

    2016-02-01

    Obliteration of the root canal system due to accelerated dentinogenesis and dystrophic calcification can challenge the achievement of root canal treatment goals. This paper describes the application of 3D digital mapping technology for predictable navigation of obliterated canal systems during root canal treatment to avoid iatrogenic damage of the root. Digital endodontic treatment planning for anterior teeth with severely obliterated root canal systems was accomplished with the aid of computer software, based on cone beam computer tomography (CBCT) scans and intra-oral scans of the dentition. On the basis of these scans, endodontic guides were created for the planned treatment through digital designing and rapid prototyping fabrication. The custom-made guides allowed for an uncomplicated and predictable canal location and management. The method of digital designing and rapid prototyping of endodontic guides allows for reliable and predictable location of root canals of teeth with calcifically metamorphosed root canal systems. The endodontic directional guide facilitates difficult endodontic treatments at little additional cost. Copyright © 2016. Published by Elsevier Ltd.

  11. Convolutional Deep Belief Networks for Single-Cell/Object Tracking in Computational Biology and Computer Vision

    OpenAIRE

    Zhong, Bineng; Pan, Shengnan; Zhang, Hongbo; Wang, Tian; Du, Jixiang; Chen, Duansheng; Cao, Liujuan

    2016-01-01

    In this paper, we propose deep architecture to dynamically learn the most discriminative features from data for both single-cell and object tracking in computational biology and computer vision. Firstly, the discriminative features are automatically learned via a convolutional deep belief network (CDBN). Secondly, we design a simple yet effective method to transfer features learned from CDBNs on the source tasks for generic purpose to the object tracking tasks using only limited amount of tra...

  12. [Evaluation of production and clinical working time of computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays for complete denture].

    Science.gov (United States)

    Wei, L; Chen, H; Zhou, Y S; Sun, Y C; Pan, S X

    2017-02-18

    To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Twenty edentulous patients were recruited into this study, which was prospective, single blind, randomized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant difference in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (Pmanufacture custom trays by three-dimensional printing method, there is no need to pour preliminary cast after taking the primary impression, therefore, it can save the impression material and model material. As to completing denture restoration, manufacturing custom trays using FSD system is worth being

  13. Smart Makeup Mirror: Computer Augmented Mirror to Aid Makeup Application

    OpenAIRE

    岩渕, 絵里子; 椎尾, 一郎

    2008-01-01

    In this paper, we present the system that aids people in wearing makeup easily and make the process enjoyable. The proposed system is the Smart Makeup Mirror device, which is an electronic dressing table that facilitates the process of makeup application. In this system, we place a high-resolution camera on top of a computer display. We developed some functions such as Automatic zoom to a specific part of the face, Display our face from various angles , and Simulation of the lighting conditio...

  14. Utilizing Provenance in Reusable Research Objects

    Directory of Open Access Journals (Sweden)

    Zhihao Yuan

    2018-03-01

    Full Text Available Science is conducted collaboratively, often requiring the sharing of knowledge about computational experiments. When experiments include only datasets, they can be shared using Uniform Resource Identifiers (URIs or Digital Object Identifiers (DOIs. An experiment, however, seldom includes only datasets, but more often includes software, its past execution, provenance, and associated documentation. The Research Object has recently emerged as a comprehensive and systematic method for aggregation and identification of diverse elements of computational experiments. While a necessary method, mere aggregation is not sufficient for the sharing of computational experiments. Other users must be able to easily recompute on these shared research objects. Computational provenance is often the key to enable such reuse. In this paper, we show how reusable research objects can utilize provenance to correctly repeat a previous reference execution, to construct a subset of a research object for partial reuse, and to reuse existing contents of a research object for modified reuse. We describe two methods to summarize provenance that aid in understanding the contents and past executions of a research object. The first method obtains a process-view by collapsing low-level system information, and the second method obtains a summary graph by grouping related nodes and edges with the goal to obtain a graph view similar to application workflow. Through detailed experiments, we show the efficacy and efficiency of our algorithms.

  15. [Computer-aided Diagnosis and New Electronic Stethoscope].

    Science.gov (United States)

    Huang, Mei; Liu, Hongying; Pi, Xitian; Ao, Yilu; Wang, Zi

    2017-05-30

    Auscultation is an important method in early-diagnosis of cardiovascular disease and respiratory system disease. This paper presents a computer-aided diagnosis of new electronic auscultation system. It has developed an electronic stethoscope based on condenser microphone and the relevant intelligent analysis software. It has implemented many functions that combined with Bluetooth, OLED, SD card storage technologies, such as real-time heart and lung sounds auscultation in three modes, recording and playback, auscultation volume control, wireless transmission. The intelligent analysis software based on PC computer utilizes C# programming language and adopts SQL Server as the background database. It has realized play and waveform display of the auscultation sound. By calculating the heart rate, extracting the characteristic parameters of T1, T2, T12, T11, it can analyze whether the heart sound is normal, and then generate diagnosis report. Finally the auscultation sound and diagnosis report can be sent to mailbox of other doctors, which can carry out remote diagnosis. The whole system has features of fully function, high portability, good user experience, and it is beneficial to promote the use of electronic stethoscope in the hospital, at the same time, the system can also be applied to auscultate teaching and other occasions.

  16. Meeting Food Aid and Price Stabilization Objectives through Local Grain Purchase: A Review of the 1996 Experience

    OpenAIRE

    Amha, Wolday; Stepanek, Julie; Jayne, Thomas S.; Negassa, Asfaw

    1997-01-01

    The objective of this paper is to identify factors that can improve the ability of future local purchase activities to achieve a range of national food policy objectives. This analysis reviews the design and implementation of 1996 local purchase activities in Ethiopia in relation to three key policy objectives: price stabilization for farmers; promoting the development of a competitive and low-cost food marketing system; and procuring food aid resources in a cost effective manner.

  17. Object recognition in images by human vision and computer vision

    NARCIS (Netherlands)

    Chen, Q.; Dijkstra, J.; Vries, de B.

    2010-01-01

    Object recognition plays a major role in human behaviour research in the built environment. Computer based object recognition techniques using images as input are challenging, but not an adequate representation of human vision. This paper reports on the differences in object shape recognition

  18. An integrated computer aided system for integrated design of chemical processes

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Hytoft, Glen; Jaksland, Cecilia

    1997-01-01

    In this paper, an Integrated Computer Aided System (ICAS), which is particularly suitable for solving problems related to integrated design of chemical processes; is presented. ICAS features include a model generator (generation of problem specific models including model simplification and model ...... form the basis for the toolboxes. The available features of ICAS are highlighted through a case study involving the separation of binary azeotropic mixtures. (C) 1997 Elsevier Science Ltd....

  19. Freedom and necessity in computer aided composition: A thinking framework and its application

    Science.gov (United States)

    Kretz, Johannes

    This paper presents some of the author's experiences with computer aided composition (CAC): the modeling of physical movements is used to obtain plausible musical gestures in interaction with constraint programming (rule based expert systems) in order to achieve precisely structured, consistent musical material with strong inner logic and syntax in pitch material. The "Constraints Engine" by Michael Laurson implemented in OpenMusic (IRCAM) or PWGL (Sibelius Academy) can be used to set up an interactive framework for composition, which offers a balance of freedom (allowing chance operations and arbitrary decisions of the composer) and necessity (through strict rules as well as through criteria for optimization). Computer Aided Composition is moving far beyond being "algorithmic" or "mechanical". This paper proposes an approach based on evolutionary epistemology (by the Austrian biologist and philosopher Rupert Riedl). The aim is a holistic synthesis of artistic freedom and coherent structures similar to the grown order of nature.

  20. The Role of Computer-Aided Instruction in Science Courses and the Relevant Misconceptions of Pre-Service Teachers

    Science.gov (United States)

    Aksakalli, Ayhan; Turgut, Umit; Salar, Riza

    2016-01-01

    This research aims to investigate the ways in which pre-service physics teachers interact with computers, which, as an indispensable means of today's technology, are of major value in education and training, and to identify any misconceptions said teachers may have about computer-aided instruction. As part of the study, computer-based physics…

  1. Foundations of computer vision computational geometry, visual image structures and object shape detection

    CERN Document Server

    Peters, James F

    2017-01-01

    This book introduces the fundamentals of computer vision (CV), with a focus on extracting useful information from digital images and videos. Including a wealth of methods used in detecting and classifying image objects and their shapes, it is the first book to apply a trio of tools (computational geometry, topology and algorithms) in solving CV problems, shape tracking in image object recognition and detecting the repetition of shapes in single images and video frames. Computational geometry provides a visualization of topological structures such as neighborhoods of points embedded in images, while image topology supplies us with structures useful in the analysis and classification of image regions. Algorithms provide a practical, step-by-step means of viewing image structures. The implementations of CV methods in Matlab and Mathematica, classification of chapter problems with the symbols (easily solved) and (challenging) and its extensive glossary of key words, examples and connections with the fabric of C...

  2. Computer aided virtual manufacturing using Creo parametric easy to learn step by step guide

    CERN Document Server

    Kanife, Paul Obiora

    2016-01-01

    Providing a step-by-step guide for the implementation of virtual manufacturing using Creo Parametric software (formerly known as Pro-Engineer), this book creates an engaging and interactive learning experience for manufacturing engineering students. Featuring graphic illustrations of simulation processes and operations, and written in accessible English to promote user-friendliness, the book covers key topics in the field including: the engraving machining process, face milling, profile milling, surface milling, volume rough milling, expert machining, electric discharge machining (EDM), and area turning using the lathe machining process. Maximising reader insights into how to simulate material removal processes, and how to generate cutter location data and G-codes data, this valuable resource equips undergraduate, postgraduate, BTech and HND students in the fields of manufacturing engineering, computer aided design (CAD) and computer aided engineering (CAE) with transferable skills and knowledge. This book is...

  3. Computer-Aided Nodule Assessment and Risk Yield Risk Management of Adenocarcinoma: The Future of Imaging?

    Science.gov (United States)

    Foley, Finbar; Rajagopalan, Srinivasan; Raghunath, Sushravya M; Boland, Jennifer M; Karwoski, Ronald A; Maldonado, Fabien; Bartholmai, Brian J; Peikert, Tobias

    2016-01-01

    Increased clinical use of chest high-resolution computed tomography results in increased identification of lung adenocarcinomas and persistent subsolid opacities. However, these lesions range from very indolent to extremely aggressive tumors. Clinically relevant diagnostic tools to noninvasively risk stratify and guide individualized management of these lesions are lacking. Research efforts investigating semiquantitative measures to decrease interrater and intrarater variability are emerging, and in some cases steps have been taken to automate this process. However, many such methods currently are still suboptimal, require validation and are not yet clinically applicable. The computer-aided nodule assessment and risk yield software application represents a validated tool for the automated, quantitative, and noninvasive tool for risk stratification of adenocarcinoma lung nodules. Computer-aided nodule assessment and risk yield correlates well with consensus histology and postsurgical patient outcomes, and therefore may help to guide individualized patient management, for example, in identification of nodules amenable to radiological surveillance, or in need of adjunctive therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Application of a computer-aided framework for the design of CO2 capture and utilization processes

    DEFF Research Database (Denmark)

    Frauzem, Rebecca; Woodley, John; Gani, Rafiqul

    2017-01-01

    Carbon dioxide capture and utilization is a vital element of carbon dioxide emission reduction to address global warming. An integrated, computer-aided framework has been developed to achieve this. This framework adopts a three-stage approach to sustainable process synthesis-design: (i) process...... synthesis, (ii) process design and (iii) innovative design. In the first stage, reaction path synthesis is used to determine the reactions and products that are considered in processing route selection and/or generation. Various scenarios are then considered for the superstructure optimization. The selected...... steps. Then, the superstructure optimization is performed on a network containing 13 likely products giving 30 feasible processing routes, considering different scenarios and objectives. Stages 2 and 3 have been applied to the optimal solution of the first scenario, which selects the production...

  5. Detection of simulated pulmonary nodules by single-exposure dual-energy computed radiography of the chest: effect of a computer-aided diagnosis system (Part 2)

    International Nuclear Information System (INIS)

    Kido, Shoji; Kuriyama, Keiko; Kuroda, Chikazumi; Nakamura, Hironobu; Ito, Wataru; Shimura, Kazuo; Kato, Hisatoyo

    2002-01-01

    Objective: To evaluate the performance of the computer-aided diagnosis (CAD) scheme on the detection of pulmonary nodules (PNs) in single-exposure dual-energy subtraction computed radiography (CR) images of the chest, and to evaluate the effect of this CAD scheme on radiologists' detectabilities. Methods and material: We compared the detectability by the CAD scheme with the detectability by 12 observers by using conventional CR (C-CR) and bone-subtracted CR (BS-CR) images of 25 chest phantoms with a low-contrast nylon nodule. Results: Both in the CAD scheme and for the observers, the detectability of BS-CR images was superior to that of C-CR images (P<0.005). The detection performance of the CAD scheme was equal to that of the observers. The nodules detected by the CAD did not necessarily coincide with those by the observers. Thus, if observers can use the results of the CAD system as a 'second opinion', their detectabilities increase. Conclusion: The CAD system for detection of PNs in the single-exposure dual-energy subtraction method is promising for improving radiologists' detectabilities of PNs

  6. Improved object optimal synthetic description, modeling, learning, and discrimination by GEOGINE computational kernel

    Science.gov (United States)

    Fiorini, Rodolfo A.; Dacquino, Gianfranco

    2005-03-01

    GEOGINE (GEOmetrical enGINE), a state-of-the-art OMG (Ontological Model Generator) based on n-D Tensor Invariants for n-Dimensional shape/texture optimal synthetic representation, description and learning, was presented in previous conferences elsewhere recently. Improved computational algorithms based on the computational invariant theory of finite groups in Euclidean space and a demo application is presented. Progressive model automatic generation is discussed. GEOGINE can be used as an efficient computational kernel for fast reliable application development and delivery in advanced biomedical engineering, biometric, intelligent computing, target recognition, content image retrieval, data mining technological areas mainly. Ontology can be regarded as a logical theory accounting for the intended meaning of a formal dictionary, i.e., its ontological commitment to a particular conceptualization of the world object. According to this approach, "n-D Tensor Calculus" can be considered a "Formal Language" to reliably compute optimized "n-Dimensional Tensor Invariants" as specific object "invariant parameter and attribute words" for automated n-Dimensional shape/texture optimal synthetic object description by incremental model generation. The class of those "invariant parameter and attribute words" can be thought as a specific "Formal Vocabulary" learned from a "Generalized Formal Dictionary" of the "Computational Tensor Invariants" language. Even object chromatic attributes can be effectively and reliably computed from object geometric parameters into robust colour shape invariant characteristics. As a matter of fact, any highly sophisticated application needing effective, robust object geometric/colour invariant attribute capture and parameterization features, for reliable automated object learning and discrimination can deeply benefit from GEOGINE progressive automated model generation computational kernel performance. Main operational advantages over previous

  7. Computer-Aided Parallelizer and Optimizer

    Science.gov (United States)

    Jin, Haoqiang

    2011-01-01

    The Computer-Aided Parallelizer and Optimizer (CAPO) automates the insertion of compiler directives (see figure) to facilitate parallel processing on Shared Memory Parallel (SMP) machines. While CAPO currently is integrated seamlessly into CAPTools (developed at the University of Greenwich, now marketed as ParaWise), CAPO was independently developed at Ames Research Center as one of the components for the Legacy Code Modernization (LCM) project. The current version takes serial FORTRAN programs, performs interprocedural data dependence analysis, and generates OpenMP directives. Due to the widely supported OpenMP standard, the generated OpenMP codes have the potential to run on a wide range of SMP machines. CAPO relies on accurate interprocedural data dependence information currently provided by CAPTools. Compiler directives are generated through identification of parallel loops in the outermost level, construction of parallel regions around parallel loops and optimization of parallel regions, and insertion of directives with automatic identification of private, reduction, induction, and shared variables. Attempts also have been made to identify potential pipeline parallelism (implemented with point-to-point synchronization). Although directives are generated automatically, user interaction with the tool is still important for producing good parallel codes. A comprehensive graphical user interface is included for users to interact with the parallelization process.

  8. A fast algorithm for computer aided collimation gamma camera (CACAO)

    Science.gov (United States)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Franck, D.; Pihet, P.; Ballongue, P.

    2000-08-01

    The computer aided collimation gamma camera is aimed at breaking down the resolution sensitivity trade-off of the conventional parallel hole collimator. It uses larger and longer holes, having an added linear movement at the acquisition sequence. A dedicated algorithm including shift and sum, deconvolution, parabolic filtering and rotation is described. Examples of reconstruction are given. This work shows that a simple and fast algorithm, based on a diagonal dominant approximation of the problem can be derived. Its gives a practical solution to the CACAO reconstruction problem.

  9. Computer-aided system for fire fighting in an underground mine

    Energy Technology Data Exchange (ETDEWEB)

    Rosiek, F; Sikora, M; Urbanski, J [Politechnika Wroclawska (Poland). Instytut Gornictwa

    1989-01-01

    Discusses structure of an algorithm for computer-aided planning of fire fighting and rescue in an underground coal mine. The algorithm developed by the Mining Institute of the Wroclaw Technical University consists of ten options: regulations on fire fighting, fire alarm for miners working underground (rescue ways, fire zones etc.), information system for mine management, movements of fire fighting teams, distribution of fire fighting equipment, assessment of explosion hazards of fire gases, fire gas temperature control of blower operation, detection of endogenous fires, ventilation control. 2 refs.

  10. Contrast-enhanced ultrasound compared with computed tomography, magnetic resonance imaging, and positron emission tomography for diagnosing liver metastases in people with newly diagnosed colorectal cancer

    DEFF Research Database (Denmark)

    Lund, Martin; Bjerre, Thomas Abramovitz; Grønbæk, Henning

    2016-01-01

    This is the protocol for a review and there is no abstract. The objectives are as follows: To compare the accuracy of CEUS, CECT, MRI, and 18F-FDG PET-CT for diagnosing liver metastases in people with newly-diagnosed colorectal cancer. Potential sources of heterogeneity We will investigate...

  11. Computer-Aided Sustainable Process Synthesis-Design and Analysis

    DEFF Research Database (Denmark)

    Kumar Tula, Anjan

    -groups is that, the performance of the entire process can be evaluated from the contributions of the individual process-groups towards the selected flowsheet property (for example, energy consumed). The developed flowsheet property models include energy consumption, carbon footprint, product recovery, product......Process synthesis involves the investigation of chemical reactions needed to produce the desired product, selection of the separation techniques needed for downstream processing, as well as taking decisions on sequencing the involved separation operations. For an effective, efficient and flexible...... focuses on the development and application of a computer-aided framework for sustainable synthesis-design and analysis of process flowsheets by generating feasible alternatives covering the entire search space and includes analysis tools for sustainability, LCA and economics. The synthesis method is based...

  12. Towards Automatic Controller Design using Multi-Objective Evolutionary Algorithms

    DEFF Research Database (Denmark)

    Pedersen, Gerulf

    of evolutionary computation, a choice was made to use multi-objective algorithms for the purpose of aiding in automatic controller design. More specifically, the choice was made to use the Non-dominated Sorting Genetic Algorithm II (NSGAII), which is one of the most potent algorithms currently in use...... for automatic controller design. However, because the field of evolutionary computation is relatively unknown in the field of control engineering, this thesis also includes a comprehensive introduction to the basic field of evolutionary computation as well as a description of how the field has previously been......In order to design the controllers of tomorrow, a need has risen for tools that can aid in the design of these. A desire to use evolutionary computation as a tool to achieve that goal is what gave inspiration for the work contained in this thesis. After having studied the foundations...

  13. Numerical Computational Technique for Scattering from Underwater Objects

    OpenAIRE

    T. Ratna Mani; Raj Kumar; Odamapally Vijay Kumar

    2013-01-01

    This paper presents a computational technique for mono-static and bi-static scattering from underwater objects of different shape such as submarines. The scatter has been computed using finite element time domain (FETD) method, based on the superposition of reflections, from the different elements reaching the receiver at a particular instant in time. The results calculated by this method has been verified with the published results based on ramp response technique. An in-depth parametric s...

  14. Computer-aided analysis of digital dental impressions obtained from intraoral and extraoral scanners.

    Science.gov (United States)

    Bohner, Lauren Oliveira Lima; De Luca Canto, Graziela; Marció, Bruno Silva; Laganá, Dalva Cruz; Sesma, Newton; Tortamano Neto, Pedro

    2017-11-01

    The internal and marginal adaptation of a computer-aided design and computer-aided manufacturing (CAD-CAM) prosthesis relies on the quality of the 3-dimensional image. The quality of imaging systems requires evaluation. The purpose of this in vitro study was to evaluate and compare the trueness of intraoral and extraoral scanners in scanning prepared teeth. Ten acrylic resin teeth to be used as a reference dataset were prepared according to standard guidelines and scanned with an industrial computed tomography system. Data were acquired with 4 scanner devices (n=10): the Trios intraoral scanner (TIS), the D250 extraoral scanner (DES), the Cerec Bluecam intraoral scanner (CBIS), and the Cerec InEosX5 extraoral scanner (CIES). For intraoral scanners, each tooth was digitized individually. Extraoral scanning was obtained from dental casts of each prepared tooth. The discrepancy between each scan and its respective reference model was obtained by deviation analysis (μm) and volume/area difference (μm). Statistical analysis was performed using linear models for repeated measurement factors test and 1-way ANOVA (α=.05). No significant differences in deviation values were found among scanners. For CBIS and CIES, the deviation was significantly higher (PDentistry. Published by Elsevier Inc. All rights reserved.

  15. APPLICATION OF COMPUTER-AIDED TOMOGRAPHY TO VISUALIZE AND QUANTIFY BIOGENIC STRUCTURES IN MARINE SEDIMENTS

    Science.gov (United States)

    We used computer-aided tomography (CT) for 3D visualization and 2D analysis ofmarine sediment cores from 3 stations (at 10, 75 and 118 m depths) with different environmentalimpact. Biogenic structures such as tubes and burrows were quantified and compared among st...

  16. Computer aided diagnosis of diabetic peripheral neuropathy

    Science.gov (United States)

    Chekh, Viktor; Soliz, Peter; McGrew, Elizabeth; Barriga, Simon; Burge, Mark; Luan, Shuang

    2014-03-01

    Diabetic peripheral neuropathy (DPN) refers to the nerve damage that can occur in diabetes patients. It most often affects the extremities, such as the feet, and can lead to peripheral vascular disease, deformity, infection, ulceration, and even amputation. The key to managing diabetic foot is prevention and early detection. Unfortunately, current existing diagnostic techniques are mostly based on patient sensations and exhibit significant inter- and intra-observer differences. We have developed a computer aided diagnostic (CAD) system for diabetic peripheral neuropathy. The thermal response of the feet of diabetic patients following cold stimulus is captured using an infrared camera. The plantar foot in the images from a thermal video are segmented and registered for tracking points or specific regions. The temperature recovery of each point on the plantar foot is extracted using our bio-thermal model and analyzed. The regions that exhibit abnormal ability to recover are automatically identified to aid the physicians to recognize problematic areas. The key to our CAD system is the segmentation of infrared video. The main challenges for segmenting infrared video compared to normal digital video are (1) as the foot warms up, it also warms up the surrounding, creating an ever changing contrast; and (2) there may be significant motion during imaging. To overcome this, a hybrid segmentation algorithm was developed based on a number of techniques such as continuous max-flow, model based segmentation, shape preservation, convex hull, and temperature normalization. Verifications of the automatic segmentation and registration using manual segmentation and markers show good agreement.

  17. Novel Kinds of Random Access Memory and New Vulnerabilities of Computer Aids based on Them

    Directory of Open Access Journals (Sweden)

    Alexander Mihaylovich Korotin

    2014-09-01

    Full Text Available The article discusses vulnerabilities of computer aids based on existing RAM and mechanisms for restricting exploitation of such vulnerabilities. In addition, the article discusses features and work methods of different RAM.

  18. A Computer-Based, Interactive Videodisc Job Aid and Expert System for Electron Beam Lithography Integration and Diagnostic Procedures.

    Science.gov (United States)

    Stevenson, Kimberly

    This master's thesis describes the development of an expert system and interactive videodisc computer-based instructional job aid used for assisting in the integration of electron beam lithography devices. Comparable to all comprehensive training, expert system and job aid development require a criterion-referenced systems approach treatment to…

  19. Integrated computer-aided design in automotive development development processes, geometric fundamentals, methods of CAD, knowledge-based engineering data management

    CERN Document Server

    Mario, Hirz; Gfrerrer, Anton; Lang, Johann

    2013-01-01

    The automotive industry faces constant pressure to reduce development costs and time while still increasing vehicle quality. To meet this challenge, engineers and researchers in both science and industry are developing effective strategies and flexible tools by enhancing and further integrating powerful, computer-aided design technology. This book provides a valuable overview of the development tools and methods of today and tomorrow. It is targeted not only towards professional project and design engineers, but also to students and to anyone who is interested in state-of-the-art computer-aided development. The book begins with an overview of automotive development processes and the principles of virtual product development. Focusing on computer-aided design, a comprehensive outline of the fundamentals of geometry representation provides a deeper insight into the mathematical techniques used to describe and model geometrical elements. The book then explores the link between the demands of integrated design pr...

  20. Computer-Aided Design of Microstrip GaAs Mesfet Amplifiers

    DEFF Research Database (Denmark)

    Nielsen, Niels Ole

    1976-01-01

    Results on computer-aided design of broadband GaAs MESFET amplifiers in microstrip is presented. The analysis of an amplifier is based on measured scattering parameters and a model of the microstrip structure, which includes parasitics and junction effects. The optimized performance of one stage...... amplifiers with lossless distributed matching elements is presented. Realized amplifiers are in good agreement with the theory. One stage amplifiers with a 1 ¿m FET in chip form exhibit 5.8 dB of gain in the range 8-12 GHz, while a gain of 4.5 dB from 4-8 GHz has been obtained with a packaged 1 ¿m FET....

  1. Micro computer aided beam transport for the SF cyclotron

    International Nuclear Information System (INIS)

    Honma, Toshihiro; Yamazaki, Tsutomu.

    1984-01-01

    An improvement of the beam transport system for the SF cyclotron is described. The system was designed to handle on-line alignment of the beam extracted from the SF cyclotron onto the optical axis of the transport line. It also enables to measure the beam emittance. The measurement of the emittance parameters is in particular necessary to calculate the beam optics. The calculation has been modified to become easy to handle. With the help of the computer-aided on-line beam profile measurement system, the operation of the beam transport system is very subservient to shorten the beam-tuning time and to improve the beam-transmission efficiency and the quality. (author)

  2. Computer aided system for parametric design of combination die

    Science.gov (United States)

    Naranje, Vishal G.; Hussein, H. M. A.; Kumar, S.

    2017-09-01

    In this paper, a computer aided system for parametric design of combination dies is presented. The system is developed using knowledge based system technique of artificial intelligence. The system is capable to design combination dies for production of sheet metal parts having punching and cupping operations. The system is coded in Visual Basic and interfaced with AutoCAD software. The low cost of the proposed system will help die designers of small and medium scale sheet metal industries for design of combination dies for similar type of products. The proposed system is capable to reduce design time and efforts of die designers for design of combination dies.

  3. Computer-aided approach for design of tailor-made blended products

    DEFF Research Database (Denmark)

    Yunus, Nor Alafiza; Gernaey, Krist; Woodley, John

    2012-01-01

    A computer-aided methodology has been developed for the design of blended (mixture) products. Through this methodology, it is possible to identify the most suitable chemicals for blending, and “tailor” the blend according to specified product needs (usually product attributes, e.g. performance...... as well as regulatory). The product design methodology has four tasks. First, the design problem is defined: the product needs are identified, translated into target properties and the constraints for each target property are defined. Secondly, target property models are retrieved from a property model...

  4. Computer-aided tomographic diagnosis of lymphadenopathies in malignant nonhodgkin's lymphomas

    International Nuclear Information System (INIS)

    Cheremisin, V.M.; Mazurov, V.K.; Anosov, N.A.; Savello, V.E.; Belov, A.F.; Novikov, A.A.; Mel'nichenko, V.Ya.; Nikolaevich, M.S.

    1996-01-01

    The potentialities of computer-aided tomography (CAT) in the diagnosis of lymphomas were studied. A total of 223 patients with disseminated lymphadenopathy were examined (78 with malignant non-Hodgkin's lymphomas, 48 with Hodgkin'sn disease, 54 with metastatic involvement of the lymph nodes, 18 with HIV infection, and 25 with reactive and inflammatory lymphadenopathy). CAT helped precisely assess the dissemination of the pathological process and disease stage in patients with malignant lymphomas, permitted follow up the time course of the disease, and facilitated differentiation of the condition from other diseases manifesting by disseminated lymphadenopathies

  5. Shear bond strength of computer-aided design and computer-aided manufacturing feldspathic and nano resin ceramics blocks cemented with three different generations of resin cement.

    Science.gov (United States)

    Ab-Ghani, Zuryati; Jaafar, Wahyuni; Foo, Siew Fon; Ariffin, Zaihan; Mohamad, Dasmawati

    2015-01-01

    To evaluate the shear bond strength between the dentin substrate and computer-aided design and computer-aided manufacturing feldspathic ceramic and nano resin ceramics blocks cemented with resin cement. Sixty cuboidal blocks (5 mm × 5 mm × 5 mm) were fabricated in equal numbers from feldspathic ceramic CEREC(®) Blocs PC and nano resin ceramic Lava™ Ultimate, and randomly divided into six groups (n = 10). Each block was cemented to the dentin of 60 extracted human premolar using Variolink(®) II/Syntac Classic (multi-steps etch-and-rinse adhesive bonding), NX3 Nexus(®) (two-steps etch-and-rinse adhesive bonding) and RelyX™ U200 self-adhesive cement. All specimens were thermocycled, and shear bond strength testing was done using the universal testing machine at a crosshead speed of 1.0 mm/min. Data were analyzed using one-way ANOVA. Combination of CEREC(®) Blocs PC and Variolink(®) II showed the highest mean shear bond strength (8.71 Mpa), while the lowest of 2.06 Mpa were observed in Lava™ Ultimate and RelyX™ U200. There was no significant difference in the mean shear bond strength between different blocks. Variolink(®) II cement using multi-steps etch-and-rinse adhesive bonding provided a higher shear bond strength than the self-adhesive cement RelyX U200. The shear bond strength was not affected by the type of blocks used.

  6. Secondary Maxillary and Orbital Floor Reconstruction With a Free Scapular Flap Using Cutting and Fixation Guides Created by Computer-Aided Design/Computer-Aided Manufacturing.

    Science.gov (United States)

    Morita, Daiki; Numajiri, Toshiaki; Tsujiko, Shoko; Nakamura, Hiroko; Yamochi, Ryo; Sowa, Yoshihiro; Yasuda, Makoto; Hirano, Shigeru

    2017-11-01

    Computer-aided design/computer-aided manufacturing (CAD/CAM) guides are now widely used in maxillofacial reconstruction. However, there are few reports of CAD/CAM guides being used for scapular flaps. The authors performed the secondary maxillary and orbital floor reconstruction using a free latissimus dorsi muscle, cutaneous tissue, and scapular flap designed using CAD/CAM techniques in a 72-year-old man who had undergone partial maxillectomy four years previously. The patient had diplopia, the vertical dystopia of eye position, and a large oral-nasal-cutaneous fistula. After the operation, the authors confirmed that the deviation between the postoperative and preoperative planning three-dimensional images was less than 2 mm. Because scapular guides require 3 cutting surfaces, the shape of the scapular guide is more complex than that of a conventional fibular guide. In orbital floor reconstruction, the use of a CAM technique such as that used to manufacture the authors' fixation guide is as necessary for accurate, safe, and easy reconstruction as is preoperative CAD planning. The production of a fixation guide as well as a cutting guide is particularly useful because it is difficult to determine the angle for reconstructing the orbital floor by freehand techniques. In this case, the orbital floor was reconstructed based on a mirror image of the healthy side to avoid overcompression of the orbital tissue. Although the patient's vertical dystopia of eye position was improved, diplopia was not improved because, for greater safety, the authors did not plan overcorrection of the orbital volume.

  7. Computer-aided roll pass design in rolling of airfoil shapes

    Science.gov (United States)

    Akgerman, N.; Lahoti, G. D.; Altan, T.

    1980-01-01

    This paper describes two computer-aided design (CAD) programs developed for modeling the shape rolling process for airfoil sections. The first program, SHPROL, uses a modular upper-bound method of analysis and predicts the lateral spread, elongation, and roll torque. The second program, ROLPAS, predicts the stresses, roll separating force, the roll torque and the details of metal flow by simulating the rolling process, using the slab method of analysis. ROLPAS is an interactive program; it offers graphic display capabilities and allows the user to interact with the computer via a keyboard, CRT, and a light pen. The accuracy of the computerized models was evaluated by (a) rolling a selected airfoil shape at room temperature from 1018 steel and isothermally at high temperature from Ti-6Al-4V, and (b) comparing the experimental results with computer predictions. The comparisons indicated that the CAD systems, described here, are useful for practical engineering purposes and can be utilized in roll pass design and analysis for airfoil and similar shapes.

  8. Development of computer-aided diagnosis systems in radiology

    International Nuclear Information System (INIS)

    Higashida, Yoshiharu; Arimura, Hidetaka; Kumazawa, Seiji; Morishita, Junji; Sakai, Shuji

    2006-01-01

    Computer-aided diagnosis (CAD) is a practice done by medical doctors based on computer image analysis as the second opinion, and CAD studies have been government-adopted projects. CAD is already on popular practice in the cancers of the breast by mammography, lung by flat plate and CT images, and large bowel by CT colonoscopy. This paper describes four examples of authors' actual CAD investigations. First, the temporal subtraction image analysis by CAD is for the detection of abnormality in the chest by radiographs taken at different times. Examples are shown in cases of interstitial pneumonia and lung cancer out of 34 patients with diffuse lung diseases. Second, development of CAD system is recorded for detection of aneurysm by the brain MR angiography (MRA). Third is the CAD detection of fascicles in cerebral white matters by the diffuse tensor MRI, which will help the surgery for brain tumors. Final is an automated patient recognition based on an image-matching technique using previous chest radiographs in the picture archiving and communication systems. This is on the radiograph giving biological fingerprints of the patients. CAD will be applied in a wider field of medicare not only in imaging technology. (T.I)

  9. Computer-Aided Sensor Development Focused on Security Issues.

    Science.gov (United States)

    Bialas, Andrzej

    2016-05-26

    The paper examines intelligent sensor and sensor system development according to the Common Criteria methodology, which is the basic security assurance methodology for IT products and systems. The paper presents how the development process can be supported by software tools, design patterns and knowledge engineering. The automation of this process brings cost-, quality-, and time-related advantages, because the most difficult and most laborious activities are software-supported and the design reusability is growing. The paper includes a short introduction to the Common Criteria methodology and its sensor-related applications. In the experimental section the computer-supported and patterns-based IT security development process is presented using the example of an intelligent methane detection sensor. This process is supported by an ontology-based tool for security modeling and analyses. The verified and justified models are transferred straight to the security target specification representing security requirements for the IT product. The novelty of the paper is to provide a patterns-based and computer-aided methodology for the sensors development with a view to achieving their IT security assurance. The paper summarizes the validation experiment focused on this methodology adapted for the sensors system development, and presents directions of future research.

  10. Object extraction in photogrammetric computer vision

    Science.gov (United States)

    Mayer, Helmut

    This paper discusses state and promising directions of automated object extraction in photogrammetric computer vision considering also practical aspects arising for digital photogrammetric workstations (DPW). A review of the state of the art shows that there are only few practically successful systems on the market. Therefore, important issues for a practical success of automated object extraction are identified. A sound and most important powerful theoretical background is the basis. Here, we particularly point to statistical modeling. Testing makes clear which of the approaches are suited best and how useful they are for praxis. A key for commercial success of a practical system is efficient user interaction. As the means for data acquisition are changing, new promising application areas such as extremely detailed three-dimensional (3D) urban models for virtual television or mission rehearsal evolve.

  11. Computer-aided System of Semantic Text Analysis of a Technical Specification

    OpenAIRE

    Zaboleeva-Zotova, Alla; Orlova, Yulia

    2008-01-01

    The given work is devoted to development of the computer-aided system of semantic text analysis of a technical specification. The purpose of this work is to increase efficiency of software engineering based on automation of semantic text analysis of a technical specification. In work it is offered and investigated the model of the analysis of the text of the technical project is submitted, the attribute grammar of a technical specification, intended for formalization of limited Ru...

  12. Generic Mathematical Programming Formulation and Solution for Computer-Aided Molecular Design

    DEFF Research Database (Denmark)

    Zhang, Lei; Cignitti, Stefano; Gani, Rafiqul

    2015-01-01

    This short communication presents a generic mathematical programming formulation for Computer-Aided Molecular Design (CAMD). A given CAMD problem, based on target properties, is formulated as a Mixed Integer Linear/Non-Linear Program (MILP/MINLP). The mathematical programming model presented here......, which is formulated as an MILP/MINLP problem, considers first-order and second-order molecular groups for molecular structure representation and property estimation. It is shown that various CAMD problems can be formulated and solved through this model....

  13. Image calibration and registration in cone-beam computed tomogram for measuring the accuracy of computer-aided implant surgery

    Science.gov (United States)

    Lam, Walter Y. H.; Ngan, Henry Y. T.; Wat, Peter Y. P.; Luk, Henry W. K.; Goto, Tazuko K.; Pow, Edmond H. N.

    2015-02-01

    Medical radiography is the use of radiation to "see through" a human body without breaching its integrity (surface). With computed tomography (CT)/cone beam computed tomography (CBCT), three-dimensional (3D) imaging can be produced. These imagings not only facilitate disease diagnosis but also enable computer-aided surgical planning/navigation. In dentistry, the common method for transfer of the virtual surgical planning to the patient (reality) is the use of surgical stent either with a preloaded planning (static) like a channel or a real time surgical navigation (dynamic) after registration with fiducial markers (RF). This paper describes using the corner of a cube as a radiopaque fiducial marker on an acrylic (plastic) stent, this RF allows robust calibration and registration of Cartesian (x, y, z)- coordinates for linking up the patient (reality) and the imaging (virtuality) and hence the surgical planning can be transferred in either static or dynamic way. The accuracy of computer-aided implant surgery was measured with reference to coordinates. In our preliminary model surgery, a dental implant was planned virtually and placed with preloaded surgical guide. The deviation of the placed implant apex from the planning was x=+0.56mm [more right], y=- 0.05mm [deeper], z=-0.26mm [more lingual]) which was within clinically 2mm safety range. For comparison with the virtual planning, the physically placed implant was CT/CBCT scanned and errors may be introduced. The difference of the actual implant apex to the virtual apex was x=0.00mm, y=+0.21mm [shallower], z=-1.35mm [more lingual] and this should be brought in mind when interpret the results.

  14. Automation of reliability evaluation procedures through CARE - The computer-aided reliability estimation program.

    Science.gov (United States)

    Mathur, F. P.

    1972-01-01

    Description of an on-line interactive computer program called CARE (Computer-Aided Reliability Estimation) which can model self-repair and fault-tolerant organizations and perform certain other functions. Essentially CARE consists of a repository of mathematical equations defining the various basic redundancy schemes. These equations, under program control, are then interrelated to generate the desired mathematical model to fit the architecture of the system under evaluation. The mathematical model is then supplied with ground instances of its variables and is then evaluated to generate values for the reliability-theoretic functions applied to the model.

  15. Computer-aided preparation of specifications for radial fans at VEB Lufttechnische Anlagen Berlin

    Energy Technology Data Exchange (ETDEWEB)

    Kubis, R.; Kull, W.

    1987-01-01

    The specification details the scope of delivery for radial fans on a standard page and also serves the preparation for production. In the place of previous manual preparation, a computer-aided technique for the office computer is presented that provides the technical parameters from data files out of few input data to identify the fan type. The data files and evaluative programs are based on the software tool REDABAS and the SCP operating system. Using this technique it has been possible to cut considerably the preparation time for the incoming orders.

  16. Educational aids

    International Nuclear Information System (INIS)

    Lenkeit, S.

    1989-01-01

    Educational aids include printed matter, aural media, visual media, audiovisual media and objects. A distinction is made between learning aids, which include blackboards, overhead projectors, flipcharts, wallcharts and pinboards, and learning aids, which include textbooks, worksheets, documentation and experimental equipment. The various aids are described and their use explained. The aids available at the School for Nuclear Technology of the Karlsruhe Nuclear Research Centre are described

  17. Flexible structure control experiments using a real-time workstation for computer-aided control engineering

    Science.gov (United States)

    Stieber, Michael E.

    1989-01-01

    A Real-Time Workstation for Computer-Aided Control Engineering has been developed jointly by the Communications Research Centre (CRC) and Ruhr-Universitaet Bochum (RUB), West Germany. The system is presently used for the development and experimental verification of control techniques for large space systems with significant structural flexibility. The Real-Time Workstation essentially is an implementation of RUB's extensive Computer-Aided Control Engineering package KEDDC on an INTEL micro-computer running under the RMS real-time operating system. The portable system supports system identification, analysis, control design and simulation, as well as the immediate implementation and test of control systems. The Real-Time Workstation is currently being used by CRC to study control/structure interaction on a ground-based structure called DAISY, whose design was inspired by a reflector antenna. DAISY emulates the dynamics of a large flexible spacecraft with the following characteristics: rigid body modes, many clustered vibration modes with low frequencies and extremely low damping. The Real-Time Workstation was found to be a very powerful tool for experimental studies, supporting control design and simulation, and conducting and evaluating tests withn one integrated environment.

  18. Descriptive and Computer Aided Drawing Perspective on an Unfolded Polyhedral Projection Surface

    Science.gov (United States)

    Dzwierzynska, Jolanta

    2017-10-01

    The aim of the herby study is to develop a method of direct and practical mapping of perspective on an unfolded prism polyhedral projection surface. The considered perspective representation is a rectilinear central projection onto a surface composed of several flat elements. In the paper two descriptive methods of drawing perspective are presented: direct and indirect. The graphical mapping of the effects of the representation is realized directly on the unfolded flat projection surface. That is due to the projective and graphical connection between points displayed on the polyhedral background and their counterparts received on the unfolded flat surface. For a significant improvement of the construction of line, analytical algorithms are formulated. They draw a perspective image of a segment of line passing through two different points determined by their coordinates in a spatial coordinate system of axis x, y, z. Compared to other perspective construction methods that use information about points, for computer vision and the computer aided design, our algorithms utilize data about lines, which are applied very often in architectural forms. Possibility of drawing lines in the considered perspective enables drawing an edge perspective image of an architectural object. The application of the changeable base elements of perspective as a horizon height and a station point location enable drawing perspective image from different viewing positions. The analytical algorithms for drawing perspective images are formulated in Mathcad software, however, they can be implemented in the majority of computer graphical packages, which can make drawing perspective more efficient and easier. The representation presented in the paper and the way of its direct mapping on the flat unfolded projection surface can find application in presentation of architectural space in advertisement and art.

  19. Computer-aided head film analysis: the University of California San Francisco method.

    Science.gov (United States)

    Baumrind, S; Miller, D M

    1980-07-01

    Computer technology is already assuming an important role in the management of orthodontic practices. The next 10 years are likely to see expansion in computer usage into the areas of diagnosis, treatment planning, and treatment-record keeping. In the areas of diagnosis and treatment planning, one of the first problems to be attacked will be the automation of head film analysis. The problems of constructing computer-aided systems for this purpose are considered herein in the light of the authors' 10 years of experience in developing a similar system for research purposes. The need for building in methods for automatic detection and correction of gross errors is discussed and the authors' method for doing so is presented. The construction of a rudimentary machine-readable data base for research and clinical purposes is described.

  20. Ratsnake: A Versatile Image Annotation Tool with Application to Computer-Aided Diagnosis

    Directory of Open Access Journals (Sweden)

    D. K. Iakovidis

    2014-01-01

    Full Text Available Image segmentation and annotation are key components of image-based medical computer-aided diagnosis (CAD systems. In this paper we present Ratsnake, a publicly available generic image annotation tool providing annotation efficiency, semantic awareness, versatility, and extensibility, features that can be exploited to transform it into an effective CAD system. In order to demonstrate this unique capability, we present its novel application for the evaluation and quantification of salient objects and structures of interest in kidney biopsy images. Accurate annotation identifying and quantifying such structures in microscopy images can provide an estimation of pathogenesis in obstructive nephropathy, which is a rather common disease with severe implication in children and infants. However a tool for detecting and quantifying the disease is not yet available. A machine learning-based approach, which utilizes prior domain knowledge and textural image features, is considered for the generation of an image force field customizing the presented tool for automatic evaluation of kidney biopsy images. The experimental evaluation of the proposed application of Ratsnake demonstrates its efficiency and effectiveness and promises its wide applicability across a variety of medical imaging domains.