WorldWideScience

Sample records for computer-aided detection scheme

  1. A new approach to develop computer-aided detection schemes of digital mammograms

    Science.gov (United States)

    Tan, Maxine; Qian, Wei; Pu, Jiantao; Liu, Hong; Zheng, Bin

    2015-06-01

    The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening examinations was used in this study. Among them, 812 cases were positive for cancer and 1084 were negative or benign. After segmenting the breast area, a computerized scheme was applied to compute 92 global mammographic tissue density based features on each of four mammograms of the craniocaudal (CC) and mediolateral oblique (MLO) views. After adding three existing popular risk factors (woman’s age, subjectively rated mammographic density, and family breast cancer history) into the initial feature pool, we applied a sequential forward floating selection feature selection algorithm to select relevant features from the bilateral CC and MLO view images separately. The selected CC and MLO view image features were used to train two artificial neural networks (ANNs). The results were then fused by a third ANN to build a two-stage classifier to predict the likelihood of the FFDM screening examination being positive. CAD performance was tested using a ten-fold cross-validation method. The computed area under the receiver operating characteristic curve was AUC = 0.779   ±   0.025 and the odds ratio monotonically increased from 1 to 31.55 as CAD-generated detection scores increased. The study demonstrated that this new global image feature based CAD scheme had a relatively higher discriminatory power to cue the FFDM examinations with high risk of being positive, which may provide a new CAD-cueing method to assist radiologists in reading and interpreting screening mammograms.

  2. Computer-Aided Detection of Kidney Tumor on Abdominal Computed Tomography Scans

    International Nuclear Information System (INIS)

    Kim, D.Y.; Park, J.W.

    2004-01-01

    Purpose: To implement a computer-aided detection system for kidney segmentation and kidney tumor detection on abdominal computed tomography (CT) scans. Material and Methods: Abdominal CT images were digitized with a film digitizer, and a gray-level threshold method was used to segment the kidney. Based on texture analysis performed on sample images of kidney tumors, a portion of the kidney tumor was selected as seed region for start point of the region-growing process. The average and standard deviations were used to detect the kidney tumor. Starting at the detected seed region, the region-growing method was used to segment the kidney tumor with intensity values used as an acceptance criterion for a homogeneous test. This test was performed to merge the neighboring region as kidney tumor boundary. These methods were applied on 156 transverse images of 12 cases of kidney tumors scanned using a G.E. Hispeed CT scanner and digitized with a Lumisys LS-40 film digitizer. Results: The computer-aided detection system resulted in a kidney tumor detection sensitivity of 85% and no false-positive findings. Conclusion: This computer-aided detection scheme was useful for kidney tumor detection and gave the characteristics of detected kidney tumors

  3. Applying a new computer-aided detection scheme generated imaging marker to predict short-term breast cancer risk

    Science.gov (United States)

    Mirniaharikandehei, Seyedehnafiseh; Hollingsworth, Alan B.; Patel, Bhavika; Heidari, Morteza; Liu, Hong; Zheng, Bin

    2018-05-01

    This study aims to investigate the feasibility of identifying a new quantitative imaging marker based on false-positives generated by a computer-aided detection (CAD) scheme to help predict short-term breast cancer risk. An image dataset including four view mammograms acquired from 1044 women was retrospectively assembled. All mammograms were originally interpreted as negative by radiologists. In the next subsequent mammography screening, 402 women were diagnosed with breast cancer and 642 remained negative. An existing CAD scheme was applied ‘as is’ to process each image. From CAD-generated results, four detection features including the total number of (1) initial detection seeds and (2) the final detected false-positive regions, (3) average and (4) sum of detection scores, were computed from each image. Then, by combining the features computed from two bilateral images of left and right breasts from either craniocaudal or mediolateral oblique view, two logistic regression models were trained and tested using a leave-one-case-out cross-validation method to predict the likelihood of each testing case being positive in the next subsequent screening. The new prediction model yielded the maximum prediction accuracy with an area under a ROC curve of AUC  =  0.65  ±  0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of (2.95, 6.83). The results also showed an increasing trend in the adjusted odds ratio and risk prediction scores (p  breast cancer risk.

  4. A method to test the reproducibility and to improve performance of computer-aided detection schemes for digitized mammograms

    International Nuclear Information System (INIS)

    Zheng Bin; Gur, David; Good, Walter F.; Hardesty, Lara A.

    2004-01-01

    The purpose of this study is to develop a new method for assessment of the reproducibility of computer-aided detection (CAD) schemes for digitized mammograms and to evaluate the possibility of using the implemented approach for improving CAD performance. Two thousand digitized mammograms (representing 500 cases) with 300 depicted verified masses were selected in the study. Series of images were generated for each digitized image by resampling after a series of slight image rotations. A CAD scheme developed in our laboratory was applied to all images to detect suspicious mass regions. We evaluated the reproducibility of the scheme using the detection sensitivity and false-positive rates for the original and resampled images. We also explored the possibility of improving CAD performance using three methods of combining results from the original and resampled images, including simple grouping, averaging output scores, and averaging output scores after grouping. The CAD scheme generated a detection score (from 0 to 1) for each identified suspicious region. A region with a detection score >0.5 was considered as positive. The CAD scheme detected 238 masses (79.3% case-based sensitivity) and identified 1093 false-positive regions (average 0.55 per image) in the original image dataset. In eleven repeated tests using original and ten sets of rotated and resampled images, the scheme detected a maximum of 271 masses and identified as many as 2359 false-positive regions. Two hundred and eighteen masses (80.4%) and 618 false-positive regions (26.2%) were detected in all 11 sets of images. Combining detection results improved reproducibility and the overall CAD performance. In the range of an average false-positive detection rate between 0.5 and 1 per image, the sensitivity of the scheme could be increased approximately 5% after averaging the scores of the regions detected in at least four images. At low false-positive rate (e.g., ≤average 0.3 per image), the grouping method

  5. Computer-aided detection of early interstitial lung diseases using low-dose CT images

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Cheol; Kim, Soo Hyung [School of Electronics and Computer Engineering, Chonnam National University, Gwangju 500-757 (Korea, Republic of); Tan, Jun; Wang Xingwei; Lederman, Dror; Leader, Joseph K; Zheng Bin, E-mail: zhengb@upmc.edu [Department of Radiology, University of Pittsburgh, Pittsburgh, PA 15213 (United States)

    2011-02-21

    This study aims to develop a new computer-aided detection (CAD) scheme to detect early interstitial lung disease (ILD) using low-dose computed tomography (CT) examinations. The CAD scheme classifies each pixel depicted on the segmented lung areas into positive or negative groups for ILD using a mesh-grid-based region growth method and a multi-feature-based artificial neural network (ANN). A genetic algorithm was applied to select optimal image features and the ANN structure. In testing each CT examination, only pixels selected by the mesh-grid region growth method were analyzed and classified by the ANN to improve computational efficiency. All unselected pixels were classified as negative for ILD. After classifying all pixels into the positive and negative groups, CAD computed a detection score based on the ratio of the number of positive pixels to all pixels in the segmented lung areas, which indicates the likelihood of the test case being positive for ILD. When applying to an independent testing dataset of 15 positive and 15 negative cases, the CAD scheme yielded the area under receiver operating characteristic curve (AUC = 0.884 {+-} 0.064) and 80.0% sensitivity at 85.7% specificity. The results demonstrated the feasibility of applying the CAD scheme to automatically detect early ILD using low-dose CT examinations.

  6. Image-processing techniques used in the computer-aided detection of radiographic lesions in anatomic background

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.; Yin, F.F.

    1988-01-01

    The authors developed feature-extraction techniques for use in the computer-aided detection of pulmonary nodules in digital chest images. Use of such a computer-aided detection scheme, which would alert radiologists to the locations of suspected lung nodules, is expected to reduce the number of false-negative diagnoses. False-negative diagnoses (i.e., misses) are a current problem in chest radiology with ''miss-rates'' as high as 30%. This may be due to the camouflaging effect of surrounding anatomic background on the nodule, or to the subjective and varying decision criteria used by radiologists

  7. Computer-aided detection of lung nodules in digital chest radiographs

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.M.

    1986-01-01

    The authors are developing an automated method to detect lung nodules by eliminating the ''camouflaging: effect of the lung background. In order to increase the conspicuity of the nodules, we created, from a single chest radiograph, two images: one in which the signal-to-noise ratio (S/N) of the nodule is maximized and another in which that S/N is suppressed. The difference between these two processed images was subjected to feature-extraction technique in order to isolate the nodules. The detection accuracy of the computer-aided detection scheme, as compared with unaided radiologists' performance, was determined using receiver operating characteristic curve analysis

  8. Performance of computer-aided diagnosis for detection of lacunar infarcts on brain MR images: ROC analysis of radiologists' detection

    International Nuclear Information System (INIS)

    Uchiyama, Y.; Yokoyama, R.; Hara, T.; Fujita, H.; Asano, T.; Kato, H.; Hoshi, H.; Yamakawa, H.; Iwama, T.; Ando, H.; Yamakawa, H.

    2007-01-01

    The detection and management of asymptomatic lacunar infarcts on magnetic resonance (MR) images are important tasks for radiologists to ensure the prevention of sever cerebral infarctions. However, accurate identification of lacunar infarcts is a difficult. Therefore, we developed a computer-aided diagnosis (CAD) scheme for detection of lacunar infarcts. The purpose of this study was to evaluate radiologists' performance in detection of lacunar infarcts without and with use of CAD scheme. 30 T1- and 30 T2- weighted images obtained from 30 patients were used for an observer study, which were consisted of 15 cases with a single lacunar infarct and 15 cases without any lacunar infarct. Six radiologists participated in the observer study. They interpreted lacunar infarcts first without and then with use of the scheme. For all six observers, average area under the receiver operating characteristic curve value was increased from 0.920 to 0.965 when they used the computer output. This CAD scheme might have the potential to improve the accuracy of radiologists' performance in the detection of lacunar infarcts on MR images. (orig.)

  9. Development of a computer-aided diagnostic scheme for detection of interval changes in successive whole-body bone scans

    International Nuclear Information System (INIS)

    Shiraishi, Junji; Li Qiang; Appelbaum, Daniel; Pu Yonglin; Doi, Kunio

    2007-01-01

    Bone scintigraphy is the most frequent examination among various diagnostic nuclear medicine procedures. It is a well-established imaging modality for the diagnosis of osseous metastasis and for monitoring osseous tumor response to chemotherapy and radiation therapy. Although the sensitivity of bone scan examinations for detection of bone abnormalities has been considered to be relatively high, it is time consuming to identify multiple lesions such as bone metastases of prostate and breast cancers. In addition, it is very difficult to detect subtle interval changes between two successive abnormal bone scans, because of variations in patient conditions, the accumulation of radioisotopes during each examination, and the image quality of gamma cameras. Therefore, we developed a new computer-aided diagnostic (CAD) scheme for the detection of interval changes in successive whole-body bone scans by use of a temporal subtraction image which was obtained with a nonlinear image-warping technique. We carried out 58 pairs of successive bone scans in which each scan included both posterior and anterior views. We determined 107 'gold-standard' interval changes among the 58 pairs based on the consensus of three radiologists. Our computerized scheme consisted of seven steps, i.e., initial image density normalization on each image, image matching for the paired images, temporal subtraction by use of the nonlinear image-warping technique, initial detection of interval changes by use of temporal-subtraction images, image feature extraction of candidates of interval changes, rule-based tests by use of 16 image features for removing some false positives, and display of the computer output for identified interval changes. One hundred seven gold standard interval changes included 71 hot lesions (uptake was increased compared with the previous scan, or there was new uptake in the current scan) and 36 cold lesions (uptake was decreased or disappeared) for anterior and posterior views. The

  10. Performance of computer-aided diagnosis for detection of lacunar infarcts on brain MR images: ROC analysis of radiologists' detection

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, Y.; Yokoyama, R.; Hara, T.; Fujita, H. [Dept. of Intelligent Image Information, Graduate Scholl of Medicine, Gifu Univ. (Japan); Asano, T.; Kato, H.; Hoshi, H. [Dept. of Radiology, Graduate Scholl of Medicine, Gifu Univ. (Japan); Yamakawa, H.; Iwama, T. [Dept. of Neurosurgery, Graduate Scholl of Medicine, Gifu Univ. (Japan); Ando, H. [Dept. of Neurosurgery, Gifu Municipal Hospital (Japan); Yamakawa, H. [Dept. of Emergency and Critical Care Medicine, Chuno-Kousei Hospital (Japan)

    2007-06-15

    The detection and management of asymptomatic lacunar infarcts on magnetic resonance (MR) images are important tasks for radiologists to ensure the prevention of sever cerebral infarctions. However, accurate identification of lacunar infarcts is a difficult. Therefore, we developed a computer-aided diagnosis (CAD) scheme for detection of lacunar infarcts. The purpose of this study was to evaluate radiologists' performance in detection of lacunar infarcts without and with use of CAD scheme. 30 T1- and 30 T2- weighted images obtained from 30 patients were used for an observer study, which were consisted of 15 cases with a single lacunar infarct and 15 cases without any lacunar infarct. Six radiologists participated in the observer study. They interpreted lacunar infarcts first without and then with use of the scheme. For all six observers, average area under the receiver operating characteristic curve value was increased from 0.920 to 0.965 when they used the computer output. This CAD scheme might have the potential to improve the accuracy of radiologists' performance in the detection of lacunar infarcts on MR images. (orig.)

  11. Detection of simulated pulmonary nodules by single-exposure dual-energy computed radiography of the chest: effect of a computer-aided diagnosis system (Part 2)

    International Nuclear Information System (INIS)

    Kido, Shoji; Kuriyama, Keiko; Kuroda, Chikazumi; Nakamura, Hironobu; Ito, Wataru; Shimura, Kazuo; Kato, Hisatoyo

    2002-01-01

    Objective: To evaluate the performance of the computer-aided diagnosis (CAD) scheme on the detection of pulmonary nodules (PNs) in single-exposure dual-energy subtraction computed radiography (CR) images of the chest, and to evaluate the effect of this CAD scheme on radiologists' detectabilities. Methods and material: We compared the detectability by the CAD scheme with the detectability by 12 observers by using conventional CR (C-CR) and bone-subtracted CR (BS-CR) images of 25 chest phantoms with a low-contrast nylon nodule. Results: Both in the CAD scheme and for the observers, the detectability of BS-CR images was superior to that of C-CR images (P<0.005). The detection performance of the CAD scheme was equal to that of the observers. The nodules detected by the CAD did not necessarily coincide with those by the observers. Thus, if observers can use the results of the CAD system as a 'second opinion', their detectabilities increase. Conclusion: The CAD system for detection of PNs in the single-exposure dual-energy subtraction method is promising for improving radiologists' detectabilities of PNs

  12. Evaluation of computer-aided detection and diagnosis systems.

    Science.gov (United States)

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in

  13. Optimization of Network Topology in Computer-Aided Detection Schemes Using Phased Searching with NEAT in a Time-Scaled Framework.

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-01-01

    In the field of computer-aided mammographic mass detection, many different features and classifiers have been tested. Frequently, the relevant features and optimal topology for the artificial neural network (ANN)-based approaches at the classification stage are unknown, and thus determined by trial-and-error experiments. In this study, we analyzed a classifier that evolves ANNs using genetic algorithms (GAs), which combines feature selection with the learning task. The classifier named "Phased Searching with NEAT in a Time-Scaled Framework" was analyzed using a dataset with 800 malignant and 800 normal tissue regions in a 10-fold cross-validation framework. The classification performance measured by the area under a receiver operating characteristic (ROC) curve was 0.856 ± 0.029. The result was also compared with four other well-established classifiers that include fixed-topology ANNs, support vector machines (SVMs), linear discriminant analysis (LDA), and bagged decision trees. The results show that Phased Searching outperformed the LDA and bagged decision tree classifiers, and was only significantly outperformed by SVM. Furthermore, the Phased Searching method required fewer features and discarded superfluous structure or topology, thus incurring a lower feature computational and training and validation time requirement. Analyses performed on the network complexities evolved by Phased Searching indicate that it can evolve optimal network topologies based on its complexification and simplification parameter selection process. From the results, the study also concluded that the three classifiers - SVM, fixed-topology ANN, and Phased Searching with NeuroEvolution of Augmenting Topologies (NEAT) in a Time-Scaled Framework - are performing comparably well in our mammographic mass detection scheme.

  14. Computer-aided diagnostic scheme for the detection of lung nodules on chest radiographs: Localized search method based on anatomical classification

    International Nuclear Information System (INIS)

    Shiraishi, Junji; Li Qiang; Suzuki, Kenji; Engelmann, Roger; Doi, Kunio

    2006-01-01

    We developed an advanced computer-aided diagnostic (CAD) scheme for the detection of various types of lung nodules on chest radiographs intended for implementation in clinical situations. We used 924 digitized chest images (992 noncalcified nodules) which had a 500x500 matrix size with a 1024 gray scale. The images were divided randomly into two sets which were used for training and testing of the computerized scheme. In this scheme, the lung field was first segmented by use of a ribcage detection technique, and then a large search area (448x448 matrix size) within the chest image was automatically determined by taking into account the locations of a midline and a top edge of the segmented ribcage. In order to detect lung nodule candidates based on a localized search method, we divided the entire search area into 7x7 regions of interest (ROIs: 64x64 matrix size). In the next step, each ROI was classified anatomically into apical, peripheral, hilar, and diaphragm/heart regions by use of its image features. Identification of lung nodule candidates and extraction of image features were applied for each localized region (128x128 matrix size), each having its central part (64x64 matrix size) located at a position corresponding to a ROI that was classified anatomically in the previous step. Initial candidates were identified by use of the nodule-enhanced image obtained with the average radial-gradient filtering technique, in which the filter size was varied adaptively depending on the location and the anatomical classification of the ROI. We extracted 57 image features from the original and nodule-enhanced images based on geometric, gray-level, background structure, and edge-gradient features. In addition, 14 image features were obtained from the corresponding locations in the contralateral subtraction image. A total of 71 image features were employed for three sequential artificial neural networks (ANNs) in order to reduce the number of false-positive candidates. All

  15. Computer-Aided Detection of Polyps in CT Colonography Using Logistic Regression

    NARCIS (Netherlands)

    Van Ravesteijn, V.F.; Van Wijk, C.; Vos, F.M.; Truyen, R.; Peters, J.F.; Stoker, J.; Van Vliet, L.J.

    2010-01-01

    We present a computer-aided detection (CAD) system for computed tomography colonography that orders the polyps according to clinical relevance. TheCADsystem consists of two steps: candidate detection and supervised classification. The characteristics of the detection step lead to specific choices

  16. Information-Aided Smart Schemes for Vehicle Flow Detection Enhancements of Traffic Microwave Radar Detectors

    Directory of Open Access Journals (Sweden)

    Tan-Jan Ho

    2016-07-01

    Full Text Available For satisfactory traffic management of an intelligent transport system, it is vital that traffic microwave radar detectors (TMRDs can provide real-time traffic information with high accuracy. In this study, we develop several information-aided smart schemes for traffic detection improvements of TMRDs in multiple-lane environments. Specifically, we select appropriate thresholds not only for removing noise from fast Fourier transforms (FFTs of regional lane contexts but also for reducing FFT side lobes within each lane. The resulting FFTs of reflected vehicle signals and those of clutter are distinguishable. We exploit FFT and lane-/or time stamp-related information for developing smart schemes, which mitigate adverse effects of lane-crossing FFT side lobes of a vehicle signal. As such, the proposed schemes can enhance the detection accuracy of both lane vehicle flow and directional traffic volume. On-site experimental results demonstrate the advantages and feasibility of the proposed methods, and suggest the best smart scheme.

  17. Computer Aided Detection of Breast Masses in Digital Tomosynthesis

    National Research Council Canada - National Science Library

    Singh, Swatee; Lo, Joseph

    2008-01-01

    The purpose of this study was to investigate feasibility of computer-aided detection of masses and calcification clusters in breast tomosynthesis images and obtain reliable estimates of sensitivity...

  18. Applying a computer-aided scheme to detect a new radiographic image marker for prediction of chemotherapy outcome

    International Nuclear Information System (INIS)

    Wang, Yunzhi; Qiu, Yuchen; Thai, Theresa; Moore, Kathleen; Liu, Hong; Zheng, Bin

    2016-01-01

    To investigate the feasibility of automated segmentation of visceral and subcutaneous fat areas from computed tomography (CT) images of ovarian cancer patients and applying the computed adiposity-related image features to predict chemotherapy outcome. A computerized image processing scheme was developed to segment visceral and subcutaneous fat areas, and compute adiposity-related image features. Then, logistic regression models were applied to analyze association between the scheme-generated assessment scores and progression-free survival (PFS) of patients using a leave-one-case-out cross-validation method and a dataset involving 32 patients. The correlation coefficients between automated and radiologist’s manual segmentation of visceral and subcutaneous fat areas were 0.76 and 0.89, respectively. The scheme-generated prediction scores using adiposity-related radiographic image features significantly associated with patients’ PFS (p < 0.01). Using a computerized scheme enables to more efficiently and robustly segment visceral and subcutaneous fat areas. The computed adiposity-related image features also have potential to improve accuracy in predicting chemotherapy outcome

  19. Development and evaluation of a computer-aided diagnostic scheme for lung nodule detection in chest radiographs by means of two-stage nodule enhancement with support vector classification

    International Nuclear Information System (INIS)

    Chen Sheng; Suzuki, Kenji; MacMahon, Heber

    2011-01-01

    Purpose: To develop a computer-aided detection (CADe) scheme for nodules in chest radiographs (CXRs) with a high sensitivity and a low false-positive (FP) rate. Methods: The authors developed a CADe scheme consisting of five major steps, which were developed for improving the overall performance of CADe schemes. First, to segment the lung fields accurately, the authors developed a multisegment active shape model. Then, a two-stage nodule-enhancement technique was developed for improving the conspicuity of nodules. Initial nodule candidates were detected and segmented by using the clustering watershed algorithm. Thirty-one shape-, gray-level-, surface-, and gradient-based features were extracted from each segmented candidate for determining the feature space, including one of the new features based on the Canny edge detector to eliminate a major FP source caused by rib crossings. Finally, a nonlinear support vector machine (SVM) with a Gaussian kernel was employed for classification of the nodule candidates. Results: To evaluate and compare the scheme to other published CADe schemes, the authors used a publicly available database containing 140 nodules in 140 CXRs and 93 normal CXRs. The CADe scheme based on the SVM classifier achieved sensitivities of 78.6% (110/140) and 71.4% (100/140) with averages of 5.0 (1165/233) FPs/image and 2.0 (466/233) FPs/image, respectively, in a leave-one-out cross-validation test, whereas the CADe scheme based on a linear discriminant analysis classifier had a sensitivity of 60.7% (85/140) at an FP rate of 5.0 FPs/image. For nodules classified as ''very subtle'' and ''extremely subtle,'' a sensitivity of 57.1% (24/42) was achieved at an FP rate of 5.0 FPs/image. When the authors used a database developed at the University of Chicago, the sensitivities was 83.3% (40/48) and 77.1% (37/48) at an FP rate of 5.0 (240/48) FPs/image and 2.0 (96/48) FPs /image, respectively. Conclusions: These results compare favorably to those described for

  20. Computer-aided Detection of Lung Cancer on Chest Radiographs: Effect on Observer Performance

    NARCIS (Netherlands)

    de Hoop, Bartjan; de Boo, Diederik W.; Gietema, Hester A.; van Hoorn, Frans; Mearadji, Banafsche; Schijf, Laura; van Ginneken, Bram; Prokop, Mathias; Schaefer-Prokop, Cornelia

    2010-01-01

    Purpose: To assess how computer-aided detection (CAD) affects reader performance in detecting early lung cancer on chest radiographs. Materials and Methods: In this ethics committee-approved study, 46 individuals with 49 computed tomographically (CT)-detected and histologically proved lung cancers

  1. Article Commentary: Computer-Aided Detection of Breast Cancer — Have All Bases Been Covered?

    Directory of Open Access Journals (Sweden)

    Gautam S. Muralidhar

    2008-01-01

    Full Text Available The use of computer-aided detection (CAD systems in mammography has been the subject of intense research for many years. These systems have been developed with the aim of helping radiologists to detect signs of breast cancer. However, the effectiveness of CAD systems in practice has sparked recent debate. In this commentary, we argue that computer-aided detection will become an increasingly important tool for radiologists in the early detection of breast cancer, but there are some important issues that need to be given greater focus in designing CAD systems if they are to reach their full potential.

  2. Computer aided detection system for lung cancer using computer tomography scans

    Science.gov (United States)

    Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.

    2018-04-01

    Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.

  3. Computer-aided detection systems to improve lung cancer early diagnosis: state-of-the-art and challenges

    International Nuclear Information System (INIS)

    Traverso, A; Lopez Torres, E; Cerello, P; Fantacci, M E

    2017-01-01

    Lung cancer is one of the most lethal types of cancer, because its early diagnosis is not good enough. In fact, the detection of pulmonary nodule, potential lung cancers, in Computed Tomography scans is a very challenging and time-consuming task for radiologists. To support radiologists, researchers have developed Computer-Aided Diagnosis (CAD) systems for the automated detection of pulmonary nodules in chest Computed Tomography scans. Despite the high level of technological developments and the proved benefits on the overall detection performance, the usage of Computer-Aided Diagnosis in clinical practice is far from being a common procedure. In this paper we investigate the causes underlying this discrepancy and present a solution to tackle it: the M5L WEB- and Cloud-based on-demand Computer-Aided Diagnosis. In addition, we prove how the combination of traditional imaging processing techniques with state-of-art advanced classification algorithms allows to build a system whose performance could be much larger than any Computer-Aided Diagnosis developed so far. This outcome opens the possibility to use the CAD as clinical decision support for radiologists. (paper)

  4. Computer-aided detection systems to improve lung cancer early diagnosis: state-of-the-art and challenges

    Science.gov (United States)

    Traverso, A.; Lopez Torres, E.; Fantacci, M. E.; Cerello, P.

    2017-05-01

    Lung cancer is one of the most lethal types of cancer, because its early diagnosis is not good enough. In fact, the detection of pulmonary nodule, potential lung cancers, in Computed Tomography scans is a very challenging and time-consuming task for radiologists. To support radiologists, researchers have developed Computer-Aided Diagnosis (CAD) systems for the automated detection of pulmonary nodules in chest Computed Tomography scans. Despite the high level of technological developments and the proved benefits on the overall detection performance, the usage of Computer-Aided Diagnosis in clinical practice is far from being a common procedure. In this paper we investigate the causes underlying this discrepancy and present a solution to tackle it: the M5L WEB- and Cloud-based on-demand Computer-Aided Diagnosis. In addition, we prove how the combination of traditional imaging processing techniques with state-of-art advanced classification algorithms allows to build a system whose performance could be much larger than any Computer-Aided Diagnosis developed so far. This outcome opens the possibility to use the CAD as clinical decision support for radiologists.

  5. Computer-Aided Detection in Breast Magnetic Resonance Imaging: A Review

    NARCIS (Netherlands)

    Dorrius, M. D.; Van Ooijen, P.M.A.

    2008-01-01

    The aim of this study is to give an overview on the accuracy of the discrimination between benign and malignant breast lesions on MRI with and without the use of a computer-aided detection (CAD) system. One investigator selected relevant articles based on title and abstract. Ten articles were

  6. Server-Aided Verification Signature with Privacy for Mobile Computing

    Directory of Open Access Journals (Sweden)

    Lingling Xu

    2015-01-01

    Full Text Available With the development of wireless technology, much data communication and processing has been conducted in mobile devices with wireless connection. As we know that the mobile devices will always be resource-poor relative to static ones though they will improve in absolute ability, therefore, they cannot process some expensive computational tasks due to the constrained computational resources. According to this problem, server-aided computing has been studied in which the power-constrained mobile devices can outsource some expensive computation to a server with powerful resources in order to reduce their computational load. However, in existing server-aided verification signature schemes, the server can learn some information about the message-signature pair to be verified, which is undesirable especially when the message includes some secret information. In this paper, we mainly study the server-aided verification signatures with privacy in which the message-signature pair to be verified can be protected from the server. Two definitions of privacy for server-aided verification signatures are presented under collusion attacks between the server and the signer. Then based on existing signatures, two concrete server-aided verification signature schemes with privacy are proposed which are both proved secure.

  7. PACS-Based Computer-Aided Detection and Diagnosis

    Science.gov (United States)

    Huang, H. K. (Bernie); Liu, Brent J.; Le, Anh HongTu; Documet, Jorge

    The ultimate goal of Picture Archiving and Communication System (PACS)-based Computer-Aided Detection and Diagnosis (CAD) is to integrate CAD results into daily clinical practice so that it becomes a second reader to aid the radiologist's diagnosis. Integration of CAD and Hospital Information System (HIS), Radiology Information System (RIS) or PACS requires certain basic ingredients from Health Level 7 (HL7) standard for textual data, Digital Imaging and Communications in Medicine (DICOM) standard for images, and Integrating the Healthcare Enterprise (IHE) workflow profiles in order to comply with the Health Insurance Portability and Accountability Act (HIPAA) requirements to be a healthcare information system. Among the DICOM standards and IHE workflow profiles, DICOM Structured Reporting (DICOM-SR); and IHE Key Image Note (KIN), Simple Image and Numeric Report (SINR) and Post-processing Work Flow (PWF) are utilized in CAD-HIS/RIS/PACS integration. These topics with examples are presented in this chapter.

  8. Observer training for computer-aided detection of pulmonary nodules in chest radiography

    NARCIS (Netherlands)

    de Boo, Diederick W.; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J.; Freling, Nicole J.; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M.

    2012-01-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a

  9. Computer-aided detection (CAD) of lung nodules and small tumours on chest radiographs

    International Nuclear Information System (INIS)

    De Boo, D.W.; Prokop, M.; Uffmann, M.; Ginneken, B. van; Schaefer-Prokop, C.M.

    2009-01-01

    Detection of focal pulmonary lesions is limited by quantum and anatomic noise and highly influenced by variable perception capacity of the reader. Multiple studies have proven that lesions - missed at time of primary interpretation - were visible on the chest radiographs in retrospect. Computer-aided diagnosis (CAD) schemes do not alter the anatomic noise but aim at decreasing the intrinsic limitations and variations of human perception by alerting the reader to suspicious areas in a chest radiograph when used as a 'second reader'. Multiple studies have shown that the detection performance can be improved using CAD especially for less experienced readers at a variable amount of decreased specificity. There seem to be a substantial learning process for both, experienced and inexperienced readers, to be able to optimally differentiate between false positive and true positive lesions and to build up sufficient trust in the capabilities of these systems to be able to use them at their full advantage. Studies so far focussed on stand-alone performance of the CAD schemes to reveal the magnitude of potential impact or on retrospective evaluation of CAD as a second reader for selected study groups. Further research is needed to assess the performance of these systems in clinical routine and to determine the trade-off between performance increase in terms of increased sensitivity and decreased inter-reader variability and loss of specificity and secondary indicated follow-up examinations for further diagnostic workup.

  10. Computer-aided detection and automated CT volumetry of pulmonary nodules

    International Nuclear Information System (INIS)

    Marten, Katharina; Engelke, Christoph

    2007-01-01

    With use of multislice computed tomography (MSCT), small pulmonary nodules are being detected in vast numbers, constituting the majority of all noncalcified lung nodules. Although the prevalence of lung cancers among such lesions in lung cancer screening populations is low, their isolation may contribute to increased patient survival. Computer-aided diagnosis (CAD) has emerged as a diverse set of diagnostic tools to handle the large number of images in MSCT datasets and most importantly, includes automated detection and volumetry of pulmonary nodules. Current CAD systems can significantly enhance experienced radiologists' performance and outweigh human limitations in identifying small lesions and manually measuring their diameters, augment observer consistency in the interpretation of such examinations and may thus help to detect significantly higher rates of early malignomas and give more precise estimates on chemotherapy response than can radiologists alone. In this review, we give an overview of current CAD in lung nodule detection and volumetry and discuss their relative merits and limitations. (orig.)

  11. Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

    Science.gov (United States)

    Doi, Kunio

    2007-01-01

    Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. In this article, the motivation and philosophy for early development of CAD schemes are presented together with the current status and future potential of CAD in a PACS environment. With CAD, radiologists use the computer output as a "second opinion" and make the final decisions. CAD is a concept established by taking into account equally the roles of physicians and computers, whereas automated computer diagnosis is a concept based on computer algorithms only. With CAD, the performance by computers does not have to be comparable to or better than that by physicians, but needs to be complementary to that by physicians. In fact, a large number of CAD systems have been employed for assisting physicians in the early detection of breast cancers on mammograms. A CAD scheme that makes use of lateral chest images has the potential to improve the overall performance in the detection of lung nodules when combined with another CAD scheme for PA chest images. Because vertebral fractures can be detected reliably by computer on lateral chest radiographs, radiologists' accuracy in the detection of vertebral fractures would be improved by the use of CAD, and thus early diagnosis of osteoporosis would become possible. In MRA, a CAD system has been developed for assisting radiologists in the detection of intracranial aneurysms. On successive bone scan images, a CAD scheme for detection of interval changes has been developed by use of temporal subtraction images. In the future, many CAD schemes could be assembled as packages and implemented as a part of PACS. For example, the package for chest CAD may include the computerized detection of lung nodules, interstitial opacities, cardiomegaly, vertebral fractures, and interval changes in chest radiographs as well as the computerized classification of benign and malignant nodules and the differential diagnosis of

  12. Computer-aided detection in breast MRI : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Dorrius, Monique D.; Jansen-van der Weide, Marijke C.; van Ooijen, Peter M. A.; Pijnappel, Ruud M.; Oudkerk, Matthijs

    To evaluate the additional value of computer-aided detection (CAD) in breast MRI by assessing radiologists' accuracy in discriminating benign from malignant breast lesions. A literature search was performed with inclusion of relevant studies using a commercially available CAD system with automatic

  13. Computer aided detection of masses in mammography using subregion Hotelling observers

    International Nuclear Information System (INIS)

    Baydush, Alan H.; Catarious, David M.; Abbey, Craig K.; Floyd, Carey E.

    2003-01-01

    We propose to investigate the use of the subregion Hotelling observer for the basis of a computer aided detection scheme for masses in mammography. A database of 1320 regions of interest (ROIs) was selected from the DDSM database collected by the University of South Florida using the Lumisys scanner cases. The breakdown of the cases was as follows: 656 normal ROIs, 307 benign ROIs, and 357 cancer ROIs. Each ROI was extracted at a size of 1024x1024 pixels and subsampled to 128x128 pixels. For the detection task, cancer and benign cases were considered positive and normal was considered negative. All positive cases had the lesion centered in the ROI. We chose to investigate the subregion Hotelling observer as a classifier to detect masses. The Hotelling observer incorporates information about the signal, the background, and the noise correlation for prediction of positive and negative and is the optimal detector when these are known. For our study, 225 subregion Hotelling observers were set up in a 15x15 grid across the center of the ROIs. Each separate observer was designed to 'observe', or discriminate, an 8x8 pixel area of the image. A leave one out training and testing methodology was used to generate 225 'features', where each feature is the output of the individual observers. The 225 features derived from separate Hotelling observers were then narrowed down by using forward searching linear discriminants (LDs). The reduced set of features was then analyzed using an additional LD with receiver operating characteristic (ROC) analysis. The 225 Hotelling observer features were searched by the forward searching LD, which selected a subset of 37 features. This subset of 37 features was then analyzed using an additional LD, which gave a ROC area under the curve of 0.9412+/-0.006 and a partial area of 0.6728. Additionally, at 98% sensitivity the overall classifier had a specificity of 55.9% and a positive predictive value of 69.3%. Preliminary results suggest that

  14. Computer-aided classification of breast masses using contrast-enhanced digital mammograms

    Science.gov (United States)

    Danala, Gopichandh; Aghaei, Faranak; Heidari, Morteza; Wu, Teresa; Patel, Bhavika; Zheng, Bin

    2018-02-01

    By taking advantages of both mammography and breast MRI, contrast-enhanced digital mammography (CEDM) has emerged as a new promising imaging modality to improve efficacy of breast cancer screening and diagnosis. The primary objective of study is to develop and evaluate a new computer-aided detection and diagnosis (CAD) scheme of CEDM images to classify between malignant and benign breast masses. A CEDM dataset consisting of 111 patients (33 benign and 78 malignant) was retrospectively assembled. Each case includes two types of images namely, low-energy (LE) and dual-energy subtracted (DES) images. First, CAD scheme applied a hybrid segmentation method to automatically segment masses depicting on LE and DES images separately. Optimal segmentation results from DES images were also mapped to LE images and vice versa. Next, a set of 109 quantitative image features related to mass shape and density heterogeneity was initially computed. Last, four multilayer perceptron-based machine learning classifiers integrated with correlationbased feature subset evaluator and leave-one-case-out cross-validation method was built to classify mass regions depicting on LE and DES images, respectively. Initially, when CAD scheme was applied to original segmentation of DES and LE images, the areas under ROC curves were 0.7585+/-0.0526 and 0.7534+/-0.0470, respectively. After optimal segmentation mapping from DES to LE images, AUC value of CAD scheme significantly increased to 0.8477+/-0.0376 (pbreast tissue on lesions, segmentation accuracy was significantly improved as compared to regular mammograms, the study demonstrated that computer-aided classification of breast masses using CEDM images yielded higher performance.

  15. Computer-aided detection of lung nodules on chest CT: issues to be solved before clinical use

    International Nuclear Information System (INIS)

    Goo, Jin Mo

    2005-01-01

    Given the increasing resolution of modern CT scanners, and the requirements for large-scale lung-screening examinations and diagnostic studies, there is an increased need for the accurate and reproducible analysis of the large number of images. Nodule detection is one of the main challenges of CT imaging, as they can be missed due to their small size, low relative contrast, or because they are located in an area with complex anatomy. Recent developments in computer-aided diagnosis (CAD) schemes are expected to aid radiologists in various tasks of chest imaging. In this era of multidetector row CT, the thoracic applications of greatest interest include the detection and volume measurement of lung nodules (1-7). Technology for CAD as applied to lung nodule detection on chest CT has been approved by the Food and Drug Administration and is currently commercially available. The article by Lee et al. (5) in this issue of the Korean Journal of Radiology is one of the few studies to examine the influence of a commercially available CAD system on the detection of lung nodules. In this study, some additional nodules were detected with the help of a CAD system, but at the expense of increased false positivity. The nodule detection rate of the CAD system in this study was lower than that achieved by radiologist, and the authors insist that the CAD system should be improved further. Compared to the use of CAD on mammograms, CAD evaluations of chest CTs remain limited to the laboratory setting. In this field, apart from the issues of detection rate and false positive detections, many obstacles must be overcome before CAD can be used in a true clinical reading environment. In this editorial, I will list some of these issues, but I emphasize now that I believe these issues will be solved by improved CAD versions in the near future

  16. Computer-aided detection in computed tomography colonography. Current status and problems with detection of early colorectal cancer

    International Nuclear Information System (INIS)

    Morimoto, Tsuyoshi; Nakijima, Yasuo; Iinuma, Gen; Arai, Yasuaki; Shiraishi, Junji; Moriyama, Noriyuki; Beddoe, G.

    2008-01-01

    The aim of this study was to evaluate the usefulness of computer-aided detection (CAD) in diagnosing early colorectal cancer using computed tomography colonography (CTC). A total of 30 CTC data sets for 30 early colorectal cancers in 30 patients were retrospectively reviewed by three radiologists. After primary evaluation, a second reading was performed using CAD findings. The readers evaluated each colorectal segment for the presence or absence of colorectal cancer using five confidence rating levels. To compare the assessment results, the sensitivity and specificity with and without CAD were calculated on the basis of the confidence rating, and differences in these variables were analyzed by receiver operating characteristic (ROC) analysis. The average sensitivities for the detection without and with CAD for the three readers were 81.6% and 75.6%, respectively. Among the three readers, only one reader improved sensitivity with CAD compared to that without. CAD decreased specificity in all three readers. CAD detected 100% of protruding lesions but only 69.2% of flat lesions. On ROC analysis, the diagnostic performance of all three readers was decreased by use of CAD. Currently available CAD with CTC does not improve diagnostic performance for detecting early colorectal cancer. An improved CAD algorithm is required for detecting fiat lesions and reducing the false-positive rate. (author)

  17. Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system

    International Nuclear Information System (INIS)

    Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter

    2002-01-01

    The aim of this study was to evaluate a computer-aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Eighty-eight consecutive spiral-CT examinations were reported by two radiologists in consensus. All examinations were reviewed using a CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm is designed to detect nodules with diameters of at least 5 mm. A total of 153 nodules were detected with at least one modality (radiologists in consensus, CAD, 85 nodules with diameter <5 mm, 68 with diameter ≥5 mm). The results of automatic nodule detection were compared to nodules detected with any modality as gold standard. Computer-aided diagnosis correctly identified 26 of 59 (38%) nodules with diameters ≥5 mm detected by visual assessment by the radiologists; of these, CAD detected 44% (24 of 54) nodules without pleural contact. In addition, 12 nodules ≥5 mm were detected which were not mentioned in the radiologist's report but represented real nodules. Sensitivity for detection of nodules ≥5 mm was 85% (58 of 68) for radiologists and 38% (26 of 68) for CAD. There were 5.8±3.6 false-positive results of CAD per CT study. Computer-aided diagnosis improves detection of pulmonary nodules at spiral CT and is a valuable second opinion in a clinical setting for lung cancer screening despite of its still limited sensitivity. (orig.)

  18. A computerized scheme for lung nodule detection in multiprojection chest radiography

    International Nuclear Information System (INIS)

    Guo Wei; Li Qiang; Boyce, Sarah J.; McAdams, H. Page; Shiraishi, Junji; Doi, Kunio; Samei, Ehsan

    2012-01-01

    Purpose: Our previous study indicated that multiprojection chest radiography could significantly improve radiologists' performance for lung nodule detection in clinical practice. In this study, the authors further verify that multiprojection chest radiography can greatly improve the performance of a computer-aided diagnostic (CAD) scheme. Methods: Our database consisted of 59 subjects, including 43 subjects with 45 nodules and 16 subjects without nodules. The 45 nodules included 7 real and 38 simulated ones. The authors developed a conventional CAD scheme and a new fusion CAD scheme to detect lung nodules. The conventional CAD scheme consisted of four steps for (1) identification of initial nodule candidates inside lungs, (2) nodule candidate segmentation based on dynamic programming, (3) extraction of 33 features from nodule candidates, and (4) false positive reduction using a piecewise linear classifier. The conventional CAD scheme processed each of the three projection images of a subject independently and discarded the correlation information between the three images. The fusion CAD scheme included the four steps in the conventional CAD scheme and two additional steps for (5) registration of all candidates in the three images of a subject, and (6) integration of correlation information between the registered candidates in the three images. The integration step retained all candidates detected at least twice in the three images of a subject and removed those detected only once in the three images as false positives. A leave-one-subject-out testing method was used for evaluation of the performance levels of the two CAD schemes. Results: At the sensitivities of 70%, 65%, and 60%, our conventional CAD scheme reported 14.7, 11.3, and 8.6 false positives per image, respectively, whereas our fusion CAD scheme reported 3.9, 1.9, and 1.2 false positives per image, and 5.5, 2.8, and 1.7 false positives per patient, respectively. The low performance of the conventional

  19. CT colonography: computer-aided detection of morphologically flat T1 colonic carcinoma

    International Nuclear Information System (INIS)

    Taylor, Stuart A.; Iinuma, Gen; Saito, Yutaka; Zhang, Jie; Halligan, Steve

    2008-01-01

    The purpose was to evaluate the ability of computer-aided detection (CAD) software to detect morphologically flat early colonic carcinoma using CT colonography (CTC). Twenty-four stage T1 colonic carcinomas endoscopically classified as flat (width over twice height) were accrued from patients undergoing staging CTC. Tumor location was annotated by three experienced radiologists in consensus aided by the endosocpic report. CAD software was then applied at three settings of sphericity (0, 0.75, and 1). Computer prompts were categorized as either true positive (overlapping tumour boundary) or false positive. True positives were subclassified as focal or non focal. The 24 cancers were endoscopically classified as type IIa (n=11) and type IIa+IIc (n=13). Mean size (range) was 27 mm (7-70 mm). CAD detected 20 (83.3%), 17 (70.8%), and 13 (54.1%) of the 24 cancers at filter settings of 0, 0.75, and 1, respectively with 3, 4, and 8 missed cancers of type IIa, respectively. The mean total number of false-positive CAD marks per patient at each filter setting was 36.5, 21.1, and 9.5, respectively, excluding polyps. At all settings, >96.1% of CAD true positives were classified as focal. CAD may be effective for the detection of morphologically flat cancer, although minimally raised laterally spreading tumors remain problematic. (orig.)

  20. A Robust and Fast System for CTC Computer-Aided Detection of Colorectal Lesions

    Directory of Open Access Journals (Sweden)

    Gareth Beddoe

    2010-01-01

    Full Text Available We present a complete, end-to-end computer-aided detection (CAD system for identifying lesions in the colon, imaged with computed tomography (CT. This system includes facilities for colon segmentation, candidate generation, feature analysis, and classification. The algorithms have been designed to offer robust performance to variation in image data and patient preparation. By utilizing efficient 2D and 3D processing, software optimizations, multi-threading, feature selection, and an optimized cascade classifier, the CAD system quickly determines a set of detection marks. The colon CAD system has been validated on the largest set of data to date, and demonstrates excellent performance, in terms of its high sensitivity, low false positive rate, and computational efficiency.

  1. Deep learning of contrast-coated serrated polyps for computer-aided detection in CT colonography

    Science.gov (United States)

    Näppi, Janne J.; Pickhardt, Perry; Kim, David H.; Hironaka, Toru; Yoshida, Hiroyuki

    2017-03-01

    Serrated polyps were previously believed to be benign lesions with no cancer potential. However, recent studies have revealed a novel molecular pathway where also serrated polyps can develop into colorectal cancer. CT colonography (CTC) can detect serrated polyps using the radiomic biomarker of contrast coating, but this requires expertise from the reader and current computer-aided detection (CADe) systems have not been designed to detect the contrast coating. The purpose of this study was to develop a novel CADe method that makes use of deep learning to detect serrated polyps based on their contrast-coating biomarker in CTC. In the method, volumetric shape-based features are used to detect polyp sites over soft-tissue and fecal-tagging surfaces of the colon. The detected sites are imaged using multi-angular 2D image patches. A deep convolutional neural network (DCNN) is used to review the image patches for the presence of polyps. The DCNN-based polyp-likelihood estimates are merged into an aggregate likelihood index where highest values indicate the presence of a polyp. For pilot evaluation, the proposed DCNN-CADe method was evaluated with a 10-fold cross-validation scheme using 101 colonoscopy-confirmed cases with 144 biopsy-confirmed serrated polyps from a CTC screening program, where the patients had been prepared for CTC with saline laxative and fecal tagging by barium and iodine-based diatrizoate. The average per-polyp sensitivity for serrated polyps >=6 mm in size was 93+/-7% at 0:8+/-1:8 false positives per patient on average. The detection accuracy was substantially higher that of a conventional CADe system. Our results indicate that serrated polyps can be detected automatically at high accuracy in CTC.

  2. [Accuracy of computer aided measurement for detecting dental proximal caries lesions in images of cone-beam computed tomography].

    Science.gov (United States)

    Zhang, Z L; Li, J P; Li, G; Ma, X C

    2017-02-09

    Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the

  3. COMPUTER-AIDED DETECTION OF ACINAR SHADOWS IN CHEST RADIOGRAPHS

    Directory of Open Access Journals (Sweden)

    Tao Xu

    2013-05-01

    Full Text Available Despite the technological advances in medical diagnosis, accurate detection of infectious tuberculosis (TB still poses challenges due to complex image features and thus infectious TB continues to be a public health problem of global proportions. Currently, the detection of TB is mainly conducted visually by radiologists examining chest radiographs (CXRs. To reduce the backlog of CXR examination and provide more precise quantitative assessment, computer-aided detection (CAD systems for potential lung lesions have been increasingly adopted and commercialized for clinical practice. CADs work as supporting tools to alert radiologists on suspected features that could have easily been neglected. In this paper, an effective CAD system aimed for acinar shadow regions detection in CXRs is proposed. This system exploits textural and photometric features analysis techniques which include local binary pattern (LBP, grey level co-occurrence matrix (GLCM and histogram of oriented gradients (HOG to analyze target regions in CXRs. Classification of acinar shadows using Adaboost is then deployed to verify the performance of a combination of these techniques. Comparative study in different image databases shows that the proposed CAD system delivers consistent high accuracy in detecting acinar shadows.

  4. Efficacy of computer-aided detection system for screening mammography

    International Nuclear Information System (INIS)

    Saito, Mioko; Ohnuki, Koji; Yamada, Takayuki; Saito, Haruo; Ishibashi, Tadashi; Ohuchi, Noriaki; Takahashi, Shoki

    2002-01-01

    A study was conducted to evaluate the efficacy of a computer-aided detection (CAD) system for screening mammography (MMG). Screening mammograms of 2,231 women aged over 50 yr were examined. Medio-lateral oblique (MLO) images were obtained, and two expert observers interpreted the mammograms by consensus. First, each mammogram was interpreted without the assistance of CAD, followed immediately by a re-evaluation of areas marked by the CAD system. Data were recorded to measure the effect of CAD on the recall rate, cancer detection rate and detection rate of masses, microcalcifications and other findings. The CAD system increased the recall rate from 2.3% to 2.6%. Six recalled cases were diagnosed as breast cancer pathologically, and CAD detected all of these lesions. Seven additional cases in which CAD detected abnormal findings had no malignancy. The detection rate of CAD for microcalcifications was high (95.0%). However, the detection rate for mass lesions and other findings was low (29.2% and 25.0% respectively). The false positivity rate was 0.13/film for microcalcifications, and 0.25/film for mass lesions. The efficacy of the CAD system for detecting microcalcifications on screening mammograms was confirmed. However, the low detection rate of mass lesions and relatively high rate of false positivity need to be further improved. (author)

  5. Evidence-based investigation of the influence of computer-aided detection of polyps on screening of colon cancer with CT colonography

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki

    2008-01-01

    Computed tomographic colonography (CTC), also known as virtual colonoscopy, is a CT examination of the colon for colorectal neoplasms. Recent large-scale clinical trials have demonstrated that CTC yields sensitivity comparable to optical colonoscopy in the detection of clinically significant polyps in a screening population, making CTC a promising technique for screening of colon cancer. For CTC to be a clinically practical means of screening, it must reliably and consistently detect polyps with high accuracy. However, high-level expertise is required to interpret the resulting CT images to find polyps, resulting in variable diagnostic accuracy among radiologists in the detection of polyps. A key technology to overcome this problem and to bring CTC to prime time for screening of colorectal cancer is computer-aided detection (CAD) of polyps. CAD automatically detects the locations of suspicious polyps in CTC images and presents them to radiologists. CAD has the potential to increase diagnostic performance in the detection of polyps as well as to reduce variability of the diagnostic accuracy among radiologists. This paper presents an evidence-based investigation of the influence of CAD on screening of colon cancer with CTC by describing the benefits of using CAD in the diagnosis of CTC, the fundamental CAD scheme for the detection of polyps in CTC, its detection performance, the effect on the improvement of detection performance, as well as the current and future challenges in CAD. (author)

  6. On Combining Multiple-Instance Learning and Active Learning for Computer-Aided Detection of Tuberculosis

    NARCIS (Netherlands)

    Melendez Rodriguez, J.C.; Ginneken, B. van; Maduskar, P.; Philipsen, R.H.H.M.; Ayles, H.; Sanchez, C.I.

    2016-01-01

    The major advantage of multiple-instance learning (MIL) applied to a computer-aided detection (CAD) system is that it allows optimizing the latter with case-level labels instead of accurate lesion outlines as traditionally required for a supervised approach. As shown in previous work, a MIL-based

  7. 3D computer-aided detection for digital breast tomosynthesis: Comparison with 2D computer-aided detection for digital mammography in the detection of calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Chu, A Jung; Cho, Nariya; Chang, Jung Min; Kim, Won Hwa; Lee, Su Hyun; Song, Sung Eun; Shin, Sung Ui; Moon, Woo Kyung [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-08-15

    To retrospectively evaluate the performance of 3D computer-aided detection (CAD) for digital breast tomosynthesis (DBT) in the detection of calcifications in comparison with 2D CAD for digital mammography (DM). Between 2012 and 2013, both 3D CAD and 2D CAD systems were retrospectively applied to the calcification data set including 69 calcifications (31 malignant calcifications and 38 benign calcifications) and the normal data set including 20 bilateral normal mammograms. Each data set consisted of paired DBT and DM images. Sensitivities for the detection of malignant calcifications were calculated from the calcification data set. False-positive mark rates were calculated from the normal data set. They were compared between the two systems. Sensitivities of 3D CAD [100% (31/31) at levels 2, 1, and 0] were same as those of the 2D CAD system [100% (31/31) at levels 2 and 1] (p = 1.0, respectively). The mean value of false-positive marks per view with 3D CAD was higher than that with 2D CAD at level 2 (0.52 marks ± 0.91 vs. 0.07 marks ± 0.26, p = 0.009). 3D CAD for DBT showed equivalent sensitivity, albeit with a higher false-positive mark rate, than 2D CAD for DM in the detection of calcifications.

  8. Observer training for computer-aided detection of pulmonary nodules in chest radiography.

    Science.gov (United States)

    De Boo, Diederick W; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J; Freling, Nicole J; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M

    2012-08-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.

  9. Max-AUC feature selection in computer-aided detection of polyps in CT colonography.

    Science.gov (United States)

    Xu, Jian-Wu; Suzuki, Kenji

    2014-03-01

    We propose a feature selection method based on a sequential forward floating selection (SFFS) procedure to improve the performance of a classifier in computerized detection of polyps in CT colonography (CTC). The feature selection method is coupled with a nonlinear support vector machine (SVM) classifier. Unlike the conventional linear method based on Wilks' lambda, the proposed method selected the most relevant features that would maximize the area under the receiver operating characteristic curve (AUC), which directly maximizes classification performance, evaluated based on AUC value, in the computer-aided detection (CADe) scheme. We presented two variants of the proposed method with different stopping criteria used in the SFFS procedure. The first variant searched all feature combinations allowed in the SFFS procedure and selected the subsets that maximize the AUC values. The second variant performed a statistical test at each step during the SFFS procedure, and it was terminated if the increase in the AUC value was not statistically significant. The advantage of the second variant is its lower computational cost. To test the performance of the proposed method, we compared it against the popular stepwise feature selection method based on Wilks' lambda for a colonic-polyp database (25 polyps and 2624 nonpolyps). We extracted 75 morphologic, gray-level-based, and texture features from the segmented lesion candidate regions. The two variants of the proposed feature selection method chose 29 and 7 features, respectively. Two SVM classifiers trained with these selected features yielded a 96% by-polyp sensitivity at false-positive (FP) rates of 4.1 and 6.5 per patient, respectively. Experiments showed a significant improvement in the performance of the classifier with the proposed feature selection method over that with the popular stepwise feature selection based on Wilks' lambda that yielded 18.0 FPs per patient at the same sensitivity level.

  10. Does Computer-aided Detection Assist in the Early Detection of Breast Cancer?

    International Nuclear Information System (INIS)

    Hukkinen, K.; Pamilo, M.

    2005-01-01

    Purpose: To evaluate whether breast cancers detected at screening are visible in previous mammograms, and to assess the performance of a computer-aided detection (CAD) system in detecting lesions in preoperative and previous mammograms. Material and Methods: Initial screening detected 67 women with 69 surgically verified breast cancers (Group A). An experienced screening radiologist retrospectively analyzed previous mammograms for visible lesions (Group B), noting in particular their size and morphology. Preoperative and previous mammograms were analyzed with CAD; a relatively inexperienced resident also analyzed previous mammograms. The performances of CAD and resident were then compared. Results: Of the 69 lesions identified, 36 were visible in previous mammograms. Of these 36 'missed' lesions, 14 were under 10 mm in diameter and 29 were mass lesions. The sensitivity of CAD was 81% in Group A and 64% in Group B. Small mass lesions were harder for CAD to detect. The specificity of CAD was 3% in Group A and 9% in Group B. Together, CAD and the resident found more 'missed' lesions than separately. Conclusion: Of the 69 breast cancers, 36 were visible in previous mammograms. CAD's sensitivity in detecting cancer lesions ranged from 64% to 81%, while specificity ranged from 9% to as low as 3%. CAD may be helpful if the radiologist is less subspecialized in mammography

  11. A new approach to develop computer-aided diagnosis scheme of breast mass classification using deep learning technology.

    Science.gov (United States)

    Qiu, Yuchen; Yan, Shiju; Gundreddy, Rohith Reddy; Wang, Yunzhi; Cheng, Samuel; Liu, Hong; Zheng, Bin

    2017-01-01

    To develop and test a deep learning based computer-aided diagnosis (CAD) scheme of mammograms for classifying between malignant and benign masses. An image dataset involving 560 regions of interest (ROIs) extracted from digital mammograms was used. After down-sampling each ROI from 512×512 to 64×64 pixel size, we applied an 8 layer deep learning network that involves 3 pairs of convolution-max-pooling layers for automatic feature extraction and a multiple layer perceptron (MLP) classifier for feature categorization to process ROIs. The 3 pairs of convolution layers contain 20, 10, and 5 feature maps, respectively. Each convolution layer is connected with a max-pooling layer to improve the feature robustness. The output of the sixth layer is fully connected with a MLP classifier, which is composed of one hidden layer and one logistic regression layer. The network then generates a classification score to predict the likelihood of ROI depicting a malignant mass. A four-fold cross validation method was applied to train and test this deep learning network. The results revealed that this CAD scheme yields an area under the receiver operation characteristic curve (AUC) of 0.696±0.044, 0.802±0.037, 0.836±0.036, and 0.822±0.035 for fold 1 to 4 testing datasets, respectively. The overall AUC of the entire dataset is 0.790±0.019. This study demonstrates the feasibility of applying a deep learning based CAD scheme to classify between malignant and benign breast masses without a lesion segmentation, image feature computation and selection process.

  12. A New Approach to Develop Computer-aided Diagnosis Scheme of Breast Mass Classification Using Deep Learning Technology

    Science.gov (United States)

    Qiu, Yuchen; Yan, Shiju; Gundreddy, Rohith Reddy; Wang, Yunzhi; Cheng, Samuel; Liu, Hong; Zheng, Bin

    2017-01-01

    PURPOSE To develop and test a deep learning based computer-aided diagnosis (CAD) scheme of mammograms for classifying between malignant and benign masses. METHODS An image dataset involving 560 regions of interest (ROIs) extracted from digital mammograms was used. After down-sampling each ROI from 512×512 to 64×64 pixel size, we applied an 8 layer deep learning network that involves 3 pairs of convolution-max-pooling layers for automatic feature extraction and a multiple layer perceptron (MLP) classifier for feature categorization to process ROIs. The 3 pairs of convolution layers contain 20, 10, and 5 feature maps, respectively. Each convolution layer is connected with a max-pooling layer to improve the feature robustness. The output of the sixth layer is fully connected with a MLP classifier, which is composed of one hidden layer and one logistic regression layer. The network then generates a classification score to predict the likelihood of ROI depicting a malignant mass. A four-fold cross validation method was applied to train and test this deep learning network. RESULTS The results revealed that this CAD scheme yields an area under the receiver operation characteristic curve (AUC) of 0.696±0.044, 0.802±0.037, 0.836±0.036, and 0.822±0.035 for fold 1 to 4 testing datasets, respectively. The overall AUC of the entire dataset is 0.790±0.019. CONCLUSIONS This study demonstrates the feasibility of applying a deep learning based CAD scheme to classify between malignant and benign breast masses without a lesion segmentation, image feature computation and selection process. PMID:28436410

  13. Ideal observer estimation and generalized ROC analysis for computer-aided diagnosis

    International Nuclear Information System (INIS)

    Edwards, Darrin C.

    2004-01-01

    The research presented in this dissertation represents an innovative application of computer-aided diagnosis and signal detection theory to the specific task of early detection of breast cancer in the context of screening mammography. A number of automated schemes have been developed in our laboratory to detect masses and clustered microcalcifications in digitized mammograms, on the one hand, and to classify known lesions as malignant or benign, on the other. The development of fully automated classification schemes is difficult, because the output of a detection scheme will contain false-positive detections in addition to detected malignant and benign lesions, resulting in a three-class classification task. Researchers have so far been unable to extend successful tools for analyzing two-class classification tasks, such as receiver operating characteristic (ROC) analysis, to three-class classification tasks. The goals of our research were to use Bayesian artificial neural networks to estimate ideal observer decision variables to both detect and classify clustered microcalcifications and mass lesions in mammograms, and to derive substantial theoretical results indicating potential avenues of approach toward the three-class classification task. Specifically, we have shown that an ideal observer in an N-class classification task achieves an optimal ROC hypersurface, just as the two-class ideal observer achieves an optimal ROC curve; and that an obvious generalization of a well-known two-class performance metric, the area under the ROC curve, is not useful as a performance metric in classification tasks with more than two classes. This work is significant for three reasons. First, it involves the explicit estimation of feature-based (as opposed to image-based) ideal observer decision variables in the tasks of detecting and classifying mammographic lesions. Second, it directly addresses the three-class classification task of distinguishing malignant lesions, benign

  14. Evaluation of the potential benefit of computer-aided diagnosis (CAD) for lung cancer screening using photofluorography

    International Nuclear Information System (INIS)

    Matsumoto, Tsuneo; Nakamura, Hiroshi; Nakanishi, Takashi; Doi, Kunio; Kano, Akiko.

    1993-01-01

    To evaluate the potential benefit of computer-aided diagnosis (CAD) in lung cancer screenings using photofluorographic films, we performed an observer test with 12 radiologists. We used 60 photofluorographic films obtained from a lung cancer screening program in Yamaguchi Prefecture (30 contained cancerous nodules and 30 had no nodules). In these cases, our current automated detection scheme achieved a sensitivity of 80%, but yielded an average of 11 false-positives per image. The observer study consisted of three viewing conditions: 1) only the original image (single reading), 2) the original image and computer output obtained from the current CAD scheme (CAD 1), 3) the original image and computer output obtained from a simulated improved CAD scheme with the same 80% true-positive rate, but with an average of one false-positive per image (CAD 2). Compared with double reading using independent interpretations, which is based on a higher score between two single readings, CAD 2 was more sensitive in subtle cases. The specificity of CAD was superior to that of double reading. Although CAD 1 (Az=0.805) was inferior to double reading (Az=0.837) in terms of the ROC curve, CAD 2 (Az=0.872) significantly improved the ROC curve and also significantly reduced observation time (p<0.05). If the number of false positives can be reduced, computer-aided diagnosis may play an important role in lung cancer screening programs. (author)

  15. Minimum Benefits for HIV/AIDS in South African Medical Schemes ...

    African Journals Online (AJOL)

    ... to the Minister of Health in respect of the extent of prescribed minimum benefits for HIV/AIDS. Medical schemes are required to provide the PMBs to their members without limits or co-payments. Keywords: Medical schemes; HIV; AIDS; benefits; prescribed minimum benefits. South African Actuarial Journal: 2003 3: 77-112 ...

  16. Computer-aided Detection Fidelity of Pulmonary Nodules in Chest Radiograph

    Directory of Open Access Journals (Sweden)

    Nikolaos Dellios

    2017-01-01

    Full Text Available Aim: The most ubiquitous chest diagnostic method is the chest radiograph. A common radiographic finding, quite often incidental, is the nodular pulmonary lesion. The detection of small lesions out of complex parenchymal structure is a daily clinical challenge. In this study, we investigate the efficacy of the computer-aided detection (CAD software package SoftView™ 2.4A for bone suppression and OnGuard™ 5.2 (Riverain Technologies, Miamisburg, OH, USA for automated detection of pulmonary nodules in chest radiographs. Subjects and Methods: We retrospectively evaluated a dataset of 100 posteroanterior chest radiographs with pulmonary nodular lesions ranging from 5 to 85 mm. All nodules were confirmed with a consecutive computed tomography scan and histologically classified as 75% malignant. The number of detected lesions by observation in unprocessed images was compared to the number and dignity of CAD-detected lesions in bone-suppressed images (BSIs. Results: SoftView™ BSI does not affect the objective lesion-to-background contrast. OnGuard™ has a stand-alone sensitivity of 62% and specificity of 58% for nodular lesion detection in chest radiographs. The false positive rate is 0.88/image and the false negative (FN rate is 0.35/image. From the true positive lesions, 20% were proven benign and 80% were malignant. FN lesions were 47% benign and 53% malignant. Conclusion: We conclude that CAD does not qualify for a stand-alone standard of diagnosis. The use of CAD accompanied with a critical radiological assessment of the software suggested pattern appears more realistic. Accordingly, it is essential to focus on studies assessing the quality-time-cost profile of real-time (as opposed to retrospective CAD implementation in clinical diagnostics.

  17. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    International Nuclear Information System (INIS)

    Destounis, S.; Hanson, S.

    2007-01-01

    This study was conducted to retrospectively evaluate a computer-aided detection system's ability to detect breast carcinoma in multiple standard mammographic projections. Forty-five lesions in 44 patients imaged with digital mammography (Selenia registered , Hologic, Bedford, MA; Senographe registered , GE, Milwaukee, WI) and had computer-aided detection (CAD, Image-checker registered V 8.3.15, Hologic/R2, Santa Clara, CA) applied at the time of examination were identified for review; all were subsequently recommended to biopsy where cancer was revealed. These lesions were determined by the study Radiologist to be visible in both standard mammographic images (mediolateral oblique, MLO; craniocaudal, CC). For each patient, case data included patient age, tissue density, lesion type, BIRADS registered assessment, lesion size, lesion visibility-visible on MLO and/or CC view, ability of CAD to correctly mark the cancerous lesion, number of CAD marks per image, needle core biopsy results and surgical pathologic correlation. For this study cohort. CAD lesion/case sensitivity of 87% (n = 39) was found and image sensitivity was found to be 69% (n = 31) for MLO view and 78% (n = 35) for the CC view. For the study cohort, cases presented with a median of four marks per cases (range 0-13). Eighty-four percent (n = 38) of lesions proceeded to excision; initial needle biopsy pathology was upgraded at surgical excision from in situ disease to invasive for 24% (n = 9) lesions. CAD has demonstrated the potential to detect mammographically visible cancers in multiple standard mammographic projections in all categories of lesions in this study cohort. (orig.)

  18. Coded-subcarrier-aided chromatic dispersion monitoring scheme for flexible optical OFDM networks.

    Science.gov (United States)

    Tse, Kam-Hon; Chan, Chun-Kit

    2014-08-11

    A simple coded-subcarrier aided scheme is proposed to perform chromatic dispersion monitoring in flexible optical OFDM networks. A pair of coded label subcarriers is added to both edges of the optical OFDM signal spectrum at the edge transmitter node. Upon reception at any intermediate or the receiver node, chromatic dispersion estimation is performed, via simple direct detection, followed by electronic correlation procedures with the designated code sequences. The feasibility and the performance of the proposed scheme have been experimentally characterized. It provides a cost-effective monitoring solution for the optical OFDM signals across intermediate nodes in flexible OFDM networks.

  19. Computer-aided system for cryogenic research facilities

    International Nuclear Information System (INIS)

    Gerasimov, V.P.; Zhelamsky, M.V.; Mozin, I.V.; Repin, S.S.

    1994-01-01

    A computer-aided system is developed for the more effective choice and optimization of the design and manufacturing technologies of the superconductor for the magnet system of the International Thermonuclear Experimental Reactor (ITER) with the aim to ensure the superconductor certification. The computer-aided system provides acquisition, processing, storage and display of data describing the proceeding tests, the detection of any parameter deviations and their analysis. Besides, it generates commands for the equipment switch off in emergency situations. ((orig.))

  20. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, Jan-Jurre; Gubern-Merida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico

    2017-01-01

    Purpose: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  1. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, J.J.; Gubern Merida, A.; Bria, A.; Tortorella, F.; Heeten, G.; Karssemeijer, N.

    2017-01-01

    PURPOSE: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  2. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening

    DEFF Research Database (Denmark)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR......) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were...... excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences...

  3. Computer-aided diagnosis of mammographic microcalcification clusters

    International Nuclear Information System (INIS)

    Kallergi, Maria

    2004-01-01

    Computer-aided diagnosis techniques in medical imaging are developed for the automated differentiation between benign and malignant lesions and go beyond computer-aided detection by providing cancer likelihood for a detected lesion given image and/or patient characteristics. The goal of this study was the development and evaluation of a computer-aided detection and diagnosis algorithm for mammographic calcification clusters. The emphasis was on the diagnostic component, although the algorithm included automated detection, segmentation, and classification steps based on wavelet filters and artificial neural networks. Classification features were selected primarily from descriptors of the morphology of the individual calcifications and the distribution of the cluster. Thirteen such descriptors were selected and, combined with patient's age, were given as inputs to the network. The features were ranked and evaluated for the classification of 100 high-resolution, digitized mammograms containing biopsy-proven, benign and malignant calcification clusters. The classification performance of the algorithm reached a 100% sensitivity for a specificity of 85% (receiver operating characteristic area index A z =0.98±0.01). Tests of the algorithm under various conditions showed that the selected features were robust morphological and distributional descriptors, relatively insensitive to segmentation and detection errors such as false positive signals. The algorithm could exceed the performance of a similar visual analysis system that was used as basis for development and, combined with a simple image standardization process, could be applied to images from different imaging systems and film digitizers with similar sensitivity and specificity rates

  4. Computer Aided Detection of Breast Masses in Digital Tomosynthesis

    Science.gov (United States)

    2008-06-01

    of unknown pathology , all other ROIs generated from that specific subject’s reconstructed volumes were excluded from the KB. For scheme B, all the FPs...query ROI of unknown pathology , all other ROIs generated from that specific subject’s reconstructed volumes were excluded from the KB. For scheme B...Qian, L. Li, and L.P. Clarke, "Image feature extraction for mass detection in digital mammography: Influence of wavelet analysis." Med. Phys. 26

  5. Standalone computer-aided detection compared to radiologists' performance for the detection of mammographic masses

    International Nuclear Information System (INIS)

    Hupse, Rianne; Samulski, Maurice; Imhof-Tas, Mechli W.; Karssemeijer, Nico; Lobbes, Marc; Boetes, Carla; Heeten, Ard den; Beijerinck, David; Pijnappel, Ruud

    2013-01-01

    We developed a computer-aided detection (CAD) system aimed at decision support for detection of malignant masses and architectural distortions in mammograms. The effect of this system on radiologists' performance depends strongly on its standalone performance. The purpose of this study was to compare the standalone performance of this CAD system to that of radiologists. In a retrospective study, nine certified screening radiologists and three residents read 200 digital screening mammograms without the use of CAD. Performances of the individual readers and of CAD were computed as the true-positive fraction (TPF) at a false-positive fraction of 0.05 and 0.2. Differences were analysed using an independent one-sample t-test. At a false-positive fraction of 0.05, the performance of CAD (TPF = 0.487) was similar to that of the certified screening radiologists (TPF = 0.518, P = 0.17). At a false-positive fraction of 0.2, CAD performance (TPF = 0.620) was significantly lower than the radiologist performance (TPF = 0.736, P <0.001). Compared to the residents, CAD performance was similar for all false-positive fractions. The sensitivity of CAD at a high specificity was comparable to that of human readers. These results show potential for CAD to be used as an independent reader in breast cancer screening. (orig.)

  6. Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yingru; Vliegenthart, Rozemarijn; Wang, Ying; Ooijen, Peter M.A. van; Oudkerk, Matthijs [University of Groningen/University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Department of Radiology, P.O. Box 30.001, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen/University Medical Center Groningen, Department of Epidemiology, P.O. Box 30.001, Groningen (Netherlands); Klaveren, Rob J. van [Lievensberg Hospital, Department of Pulmonology, P.O. Box 135, Bergen op Zoom (Netherlands); Bogoni, Luca [CAD Group, Siemens Medical Solutions USA, Inc., Malvern, PA (United States); Jong, Pim A. de; Mali, Willem P. [University of Utrecht, Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, Utrecht (Netherlands)

    2012-10-15

    To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm{sup 3}). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. circle Computer-aided detection (CAD) has known advantages for computed tomography (CT). (orig.)

  7. Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

    International Nuclear Information System (INIS)

    Zhao, Yingru; Vliegenthart, Rozemarijn; Wang, Ying; Ooijen, Peter M.A. van; Oudkerk, Matthijs; Bock, Geertruida H. de; Klaveren, Rob J. van; Bogoni, Luca; Jong, Pim A. de; Mali, Willem P.

    2012-01-01

    To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm 3 ). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. circle Computer-aided detection (CAD) has known advantages for computed tomography (CT). (orig.)

  8. Computer aided monitoring of breast abnormalities in X-ray mammograms

    OpenAIRE

    Selvan, Arul; Saatchi, Reza; Ferris, Christine

    2011-01-01

    X­ray mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, but the interpretation of mammograms is a difficult and \\ud error­prone task. Computer­aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer­aided diagnosis (CADx) systems assist the radiologist in the classification of mammographic lesions as benign or malignant[1].\\ud This p...

  9. Digital mammography: Signal-extraction strategies for computer-aided detection of microcalcifications

    International Nuclear Information System (INIS)

    Chan, H.P.; Doi, K.; Metz, C.E.; Vyborny, C.J.; Lam, K.L.; Schmidt, R.A.

    1987-01-01

    The authors found that the structured background of a mammogram can be removed effectively by either a difference-image technique (using a matched filter in combination with a median filter, a contrast-reversal filter, or a box-rim filter) or a visual response filter alone. Locally adaptive gray-level thresholding and region-growing techniques can then be employed to extract microcalcifications from the processed image. Signals are further distinguished from noise or artifacts by their size, contrast, and clustering properties. The authors studied the dependence of the detectability of microcalcifications on the various signal-extraction strategies. Potential application of the computer-aided system to mammography is assessed by its performance on clinical mammograms

  10. Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers

    International Nuclear Information System (INIS)

    Sadaf, Arifa; Crystal, Pavel; Scaranelo, Anabel; Helbich, Thomas

    2011-01-01

    Objective: The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. Materials and Methods: CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers detected with FFDM (Senographe 2000, GE Medical Systems). CAD sensitivity was assessed in total group of 127 cases and for subgroups based on breast density, mammographic lesion type, mammographic lesion size, histopathology and mode of presentation. Results: Overall CAD sensitivity was 91% (115 of 127 cases). There were no statistical differences (p > 0.1) in CAD detection of cancers in dense breasts 90% (53/59) versus non-dense breasts 91% (62/68). There was statistical difference (p 20 mm 97% (22/23). Conclusion: CAD applied to FFDM showed 100% sensitivity in identifying cancers manifesting as microcalcifications only and high sensitivity 86% (71/83) for other mammographic appearances of cancer. Sensitivity is influenced by lesion size. CAD in FFDM is an adjunct helping radiologist in early detection of breast cancers.

  11. Computer aided detection of brain micro-bleeds in traumatic brain injury

    Science.gov (United States)

    van den Heuvel, T. L. A.; Ghafoorian, M.; van der Eerden, A. W.; Goraj, B. M.; Andriessen, T. M. J. C.; ter Haar Romeny, B. M.; Platel, B.

    2015-03-01

    Brain micro-bleeds (BMBs) are used as surrogate markers for detecting diffuse axonal injury in traumatic brain injury (TBI) patients. The location and number of BMBs have been shown to influence the long-term outcome of TBI. To further study the importance of BMBs for prognosis, accurate localization and quantification are required. The task of annotating BMBs is laborious, complex and prone to error, resulting in a high inter- and intra-reader variability. In this paper we propose a computer-aided detection (CAD) system to automatically detect BMBs in MRI scans of moderate to severe neuro-trauma patients. Our method consists of four steps. Step one: preprocessing of the data. Both susceptibility (SWI) and T1 weighted MRI scans are used. The images are co-registered, a brain-mask is generated, the bias field is corrected, and the image intensities are normalized. Step two: initial candidates for BMBs are selected as local minima in the processed SWI scans. Step three: feature extraction. BMBs appear as round or ovoid signal hypo-intensities on SWI. Twelve features are computed to capture these properties of a BMB. Step four: Classification. To identify BMBs from the set of local minima using their features, different classifiers are trained on a database of 33 expert annotated scans and 18 healthy subjects with no BMBs. Our system uses a leave-one-out strategy to analyze its performance. With a sensitivity of 90% and 1.3 false positives per BMB, our CAD system shows superior results compared to state-of-the-art BMB detection algorithms (developed for non-trauma patients).

  12. Computer-aided detection of pulmonary nodules: influence of nodule characteristics on detection performance

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Seyfarth, T.; Grillhoesl, A.; Obenauer, S.; Rummeny, E.J.

    2005-01-01

    AIM: To evaluate prospectively the influence of pulmonary nodule characteristics on detection performances of a computer-aided diagnosis (CAD) tool and experienced chest radiologists using multislice CT (MSCT). MATERIALS AND METHODS: MSCT scans of 20 consecutive patients were evaluated by a CAD system and two independent chest radiologists for presence of pulmonary nodules. Nodule size, position, margin, matrix characteristics, vascular and pleural attachments and reader confidence were recorded and data compared with an independent standard of reference. Statistical analysis for predictors influencing nodule detection or reader performance included chi-squared, retrograde stepwise conditional logistic regression with odds ratios and nodule detection proportion estimates (DPE), and ROC analysis. RESULTS: For 135 nodules, detection rates for CAD and readers were 76.3, 52.6 and 52.6%, respectively; false-positive rates were 0.55, 0.25 and 0.15 per examination, respectively. In consensus with CAD the reader detection rate increased to 93.3%, and the false-positive rate dropped to 0.1/scan. DPEs for nodules ≤5 mm were significantly higher for ICAD than for the readers (p<0.05). Absence of vascular attachment was the only significant predictor of nodule detection by CAD (p=0.0006-0.008). There were no predictors of nodule detection for reader consensus with CAD. In contrast, vascular attachment predicted nodule detection by the readers (p=0.0001-0.003). Reader sensitivity was higher for nodules with vascular attachment than for unattached nodules (sensitivities 0.768 and 0.369; 95% confidence intervals=0.651-0.861 and 0.253-0.498, respectively). CONCLUSION: CAD increases nodule detection rates, decreases false-positive rates and compensates for deficient reader performance in detection of smallest lesions and of nodules without vascular attachment

  13. Effect of radiation dose reduction and iterative reconstruction on computer-aided detection of pulmonary nodules : Intra-individual comparison

    NARCIS (Netherlands)

    Den Harder, Annemarie M.; Willemink, Martin J.; Van Hamersvelt, Robbert W.; Vonken, Evert-Jan P A; Milles, Julien; Schilham, Arnold M R; Lammers, Jan Willem; De Jong, Pim A.; Leiner, Tim; Budde, Ricardo P J

    2016-01-01

    Objective To evaluate the effect of radiation dose reduction and iterative reconstruction (IR) on the performance of computer-aided detection (CAD) for pulmonary nodules. Methods In this prospective study twenty-five patients were included who were scanned for pulmonary nodule follow-up. Image

  14. Computer-aided diagnosis in radiological imaging: current status and future challenges

    Science.gov (United States)

    Doi, Kunio

    2009-10-01

    Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. Many different types of CAD schemes are being developed for detection and/or characterization of various lesions in medical imaging, including conventional projection radiography, CT, MRI, and ultrasound imaging. Commercial systems for detection of breast lesions on mammograms have been developed and have received FDA approval for clinical use. CAD may be defined as a diagnosis made by a physician who takes into account the computer output as a "second opinion". The purpose of CAD is to improve the quality and productivity of physicians in their interpretation of radiologic images. The quality of their work can be improved in terms of the accuracy and consistency of their radiologic diagnoses. In addition, the productivity of radiologists is expected to be improved by a reduction in the time required for their image readings. The computer output is derived from quantitative analysis of radiologic images by use of various methods and techniques in computer vision, artificial intelligence, and artificial neural networks (ANNs). The computer output may indicate a number of important parameters, for example, the locations of potential lesions such as lung cancer and breast cancer, the likelihood of malignancy of detected lesions, and the likelihood of various diseases based on differential diagnosis in a given image and clinical parameters. In this review article, the basic concept of CAD is first defined, and the current status of CAD research is then described. In addition, the potential of CAD in the future is discussed and predicted.

  15. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2000-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  16. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2001-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  17. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    1999-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  18. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2002-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  19. CAD for CT colonography: toward a preparation-independent scheme

    International Nuclear Information System (INIS)

    Naeppi, J.

    2007-01-01

    Computer-aided detection (CAD) systems can be used to automatically detect and display the locations of polyps and masses in computed tomographic colonography (CTC) data for assisting radiologists' image interpretation. Rapid technical advancements over the last few years have established a fundamental CAD scheme for CTC that includes the steps of colon extraction, polyp detection, and false-positive (FP) reduction. Several CAD prototype systems have demonstrated clinically acceptable high polyp detection sensitivity with relatively few FP detections in cathartic CTC, and observer studies have demonstrated the potential benefit of such systems in improving the accuracy and consistency of radiologists' detection performance. Some CAD prototype systems have also demonstrated promising performance in reduced cathartic and non-cathartic CTC. Recent advancements suggest that CAD systems can soon be expected to provide a preparation-independent scheme that can yield consistently high detection sensitivity with moderately low FP rate not only with cathartic CTC protocols but over a wide range of cathartic, reduced cathartic, and non-cathartic CTC protocols. (orig.)

  20. Improved QRD-M Detection Algorithm for Generalized Spatial Modulation Scheme

    Directory of Open Access Journals (Sweden)

    Xiaorong Jing

    2017-01-01

    Full Text Available Generalized spatial modulation (GSM is a spectral and energy efficient multiple-input multiple-output (MIMO transmission scheme. It will lead to imperfect detection performance with relatively high computational complexity by directly applying the original QR-decomposition with M algorithm (QRD-M to the GSM scheme. In this paper an improved QRD-M algorithm is proposed for GSM signal detection, which achieves near-optimal performance but with relatively low complexity. Based on the QRD, the improved algorithm firstly transforms the maximum likelihood (ML detection of the GSM signals into searching an inverted tree structure. Then, in the searching process of the M branches, the branches corresponding to the illegitimate transmit antenna combinations (TACs and related to invalid number of active antennas are cut in order to improve the validity of the resultant branches at each level by taking advantage of characteristics of GSM signals. Simulation results show that the improved QRD-M detection algorithm provides similar performance to maximum likelihood (ML with the reduced computational complexity compared to the original QRD-M algorithm, and the optimal value of parameter M of the improved QRD-M algorithm for detection of the GSM scheme is equal to modulation order plus one.

  1. Computer Aided Diagnosis System for Early Lung Cancer Detection

    Directory of Open Access Journals (Sweden)

    Fatma Taher

    2015-11-01

    Full Text Available Lung cancer continues to rank as the leading cause of cancer deaths worldwide. One of the most promising techniques for early detection of cancerous cells relies on sputum cell analysis. This was the motivation behind the design and the development of a new computer aided diagnosis (CAD system for early detection of lung cancer based on the analysis of sputum color images. The proposed CAD system encompasses four main processing steps. First is the preprocessing step which utilizes a Bayesian classification method using histogram analysis. Then, in the second step, mean shift segmentation is applied to segment the nuclei from the cytoplasm. The third step is the feature analysis. In this step, geometric and chromatic features are extracted from the nucleus region. These features are used in the diagnostic process of the sputum images. Finally, the diagnosis is completed using an artificial neural network and support vector machine (SVM for classifying the cells into benign or malignant. The performance of the system was analyzed based on different criteria such as sensitivity, specificity and accuracy. The evaluation was carried out using Receiver Operating Characteristic (ROC curve. The experimental results demonstrate the efficiency of the SVM classifier over other classifiers, with 97% sensitivity and accuracy as well as a significant reduction in the number of false positive and false negative rates.

  2. Multiple-instance learning for computer-aided detection of tuberculosis

    Science.gov (United States)

    Melendez, J.; Sánchez, C. I.; Philipsen, R. H. H. M.; Maduskar, P.; van Ginneken, B.

    2014-03-01

    Detection of tuberculosis (TB) on chest radiographs (CXRs) is a hard problem. Therefore, to help radiologists or even take their place when they are not available, computer-aided detection (CAD) systems are being developed. In order to reach a performance comparable to that of human experts, the pattern recognition algorithms of these systems are typically trained on large CXR databases that have been manually annotated to indicate the abnormal lung regions. However, manually outlining those regions constitutes a time-consuming process that, besides, is prone to inconsistencies and errors introduced by interobserver variability and the absence of an external reference standard. In this paper, we investigate an alternative pattern classi cation method, namely multiple-instance learning (MIL), that does not require such detailed information for a CAD system to be trained. We have applied this alternative approach to a CAD system aimed at detecting textural lesions associated with TB. Only the case (or image) condition (normal or abnormal) was provided in the training stage. We compared the resulting performance with those achieved by several variations of a conventional system trained with detailed annotations. A database of 917 CXRs was constructed for experimentation. It was divided into two roughly equal parts that were used as training and test sets. The area under the receiver operating characteristic curve was utilized as a performance measure. Our experiments show that, by applying the investigated MIL approach, comparable results as with the aforementioned conventional systems are obtained in most cases, without requiring condition information at the lesion level.

  3. Computer-aided detection system applied to full-field digital mammograms

    International Nuclear Information System (INIS)

    Vega Bolivar, Alfonso; Sanchez Gomez, Sonia; Merino, Paula; Alonso-Bartolome, Pilar; Ortega Garcia, Estrella; Munoz Cacho, Pedro; Hoffmeister, Jeffrey W.

    2010-01-01

    Background: Although mammography remains the mainstay for breast cancer screening, it is an imperfect examination with a sensitivity of 75-92% for breast cancer. Computer-aided detection (CAD) has been developed to improve mammographic detection of breast cancer. Purpose: To retrospectively estimate CAD sensitivity and false-positive rate with full-field digital mammograms (FFDMs). Material and Methods: CAD was used to evaluate 151 cases of ductal carcinoma in situ (DCIS) (n=48) and invasive breast cancer (n=103) detected with FFDM. Retrospectively, CAD sensitivity was estimated based on breast density, mammographic presentation, histopathology type, and lesion size. CAD false-positive rate was estimated with screening FFDMs from 200 women. Results: CAD detected 93% (141/151) of cancer cases: 97% (28/29) in fatty breasts, 94% (81/86) in breasts containing scattered fibroglandular densities, 90% (28/31) in heterogeneously dense breasts, and 80% (4/5) in extremely dense breasts. CAD detected 98% (54/55) of cancers manifesting as calcifications, 89% (74/83) as masses, and 100% (13/13) as mixed masses and calcifications. CAD detected 92% (73/79) of invasive ductal carcinomas, 89% (8/9) of invasive lobular carcinomas, 93% (14/15) of other invasive carcinomas, and 96% (46/48) of DCIS. CAD sensitivity for cancers 1-10 mm was 87% (47/54); 11-20 mm, 99% (70/71); 21-30 mm, 86% (12/14); and larger than 30 mm, 100% (12/12). The CAD false-positive rate was 2.5 marks per case. Conclusion: CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications or masses. CAD sensitivity was maintained in small lesions (1-20 mm) and invasive lobular carcinomas, which have lower mammographic sensitivity

  4. Computer-aided detection system applied to full-field digital mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Vega Bolivar, Alfonso; Sanchez Gomez, Sonia; Merino, Paula; Alonso-Bartolome, Pilar; Ortega Garcia, Estrella (Dept. of Radiology, Univ. Marques of Valdecilla Hospital, Santander (Spain)), e-mail: avegab@telefonica.net; Munoz Cacho, Pedro (Dept. of Statistics, Univ. Marques of Valdecilla Hospital, Santander (Spain)); Hoffmeister, Jeffrey W. (iCAD, Inc., Nashua, NH (United States))

    2010-12-15

    Background: Although mammography remains the mainstay for breast cancer screening, it is an imperfect examination with a sensitivity of 75-92% for breast cancer. Computer-aided detection (CAD) has been developed to improve mammographic detection of breast cancer. Purpose: To retrospectively estimate CAD sensitivity and false-positive rate with full-field digital mammograms (FFDMs). Material and Methods: CAD was used to evaluate 151 cases of ductal carcinoma in situ (DCIS) (n=48) and invasive breast cancer (n=103) detected with FFDM. Retrospectively, CAD sensitivity was estimated based on breast density, mammographic presentation, histopathology type, and lesion size. CAD false-positive rate was estimated with screening FFDMs from 200 women. Results: CAD detected 93% (141/151) of cancer cases: 97% (28/29) in fatty breasts, 94% (81/86) in breasts containing scattered fibroglandular densities, 90% (28/31) in heterogeneously dense breasts, and 80% (4/5) in extremely dense breasts. CAD detected 98% (54/55) of cancers manifesting as calcifications, 89% (74/83) as masses, and 100% (13/13) as mixed masses and calcifications. CAD detected 92% (73/79) of invasive ductal carcinomas, 89% (8/9) of invasive lobular carcinomas, 93% (14/15) of other invasive carcinomas, and 96% (46/48) of DCIS. CAD sensitivity for cancers 1-10 mm was 87% (47/54); 11-20 mm, 99% (70/71); 21-30 mm, 86% (12/14); and larger than 30 mm, 100% (12/12). The CAD false-positive rate was 2.5 marks per case. Conclusion: CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications or masses. CAD sensitivity was maintained in small lesions (1-20 mm) and invasive lobular carcinomas, which have lower mammographic sensitivity

  5. Controlled braking scheme for a wheeled walking aid

    OpenAIRE

    Coyle, Eugene; O'Dwyer, Aidan; Young, Eileen; Sullivan, Kevin; Toner, A.

    2006-01-01

    A wheeled walking aid with an embedded controlled braking system is described. The frame of the prototype is based on combining features of standard available wheeled walking aids. A braking scheme has been designed using hydraulic disc brakes to facilitate accurate and sensitive controlled stopping of the walker by the user, and if called upon, by automatic action. Braking force is modulated via a linear actuating stepping motor. A microcontroller is used for control of both stepper movement...

  6. The usefulness of a computer-aided diagnosis scheme for improving the performance of clinicians to diagnose non-mass lesions on breast ultrasonographic images.

    Science.gov (United States)

    Shibusawa, Mai; Nakayama, Ryohei; Okanami, Yuko; Kashikura, Yumi; Imai, Nao; Nakamura, Takashi; Kimura, Hiroko; Yamashita, Masako; Hanamura, Noriko; Ogawa, Tomoko

    2016-07-01

    The purpose of this study was to evaluate the usefulness of a computer-aided diagnosis (CAD) scheme for improving the performance of clinicians to diagnose non-mass lesions appearing as hypoechoic areas on breast ultrasonographic images. The database included 97 ultrasonographic images with hypoechoic areas: 48 benign cases [benign lesion with benign mammary tissue or fibrocystic disease (n = 20), fibroadenoma (n = 11), and intraductal papilloma (n = 17)] and 49 malignant cases [ductal carcinoma in situ (n = 17) and invasive ductal carcinoma (n = 32)]. Seven clinicians, three expert breast surgeons, and four general surgeons participated in the observer study. They were asked their confidence level concerning the possibility of malignancy in all 97 cases with and without the use of the CAD scheme. Receiver operating characteristic (ROC) analysis was performed to evaluate the usefulness of the CAD scheme. The areas under the ROC curve (AUC) improved for all observers when they used the CAD scheme and increased from 0.649 to 0.783 (P = 0.0167). Notably, the AUC for the general surgeon group increased from 0.625 to 0.793 (P = 0.045). This study showed that the performance of clinicians to diagnose non-mass lesions appearing as hypoechoic areas on breast ultrasonographic images was improved by the use of a CAD scheme.

  7. Three-Dimensional Computer-Aided Detection of Microcalcification Clusters in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Ji-wook Jeong

    2016-01-01

    Full Text Available We propose computer-aided detection (CADe algorithm for microcalcification (MC clusters in reconstructed digital breast tomosynthesis (DBT images. The algorithm consists of prescreening, MC detection, clustering, and false-positive (FP reduction steps. The DBT images containing the MC-like objects were enhanced by a multiscale Hessian-based three-dimensional (3D objectness response function and a connected-component segmentation method was applied to extract the cluster seed objects as potential clustering centers of MCs. Secondly, a signal-to-noise ratio (SNR enhanced image was also generated to detect the individual MC candidates and prescreen the MC-like objects. Each cluster seed candidate was prescreened by counting neighboring individual MC candidates nearby the cluster seed object according to several microcalcification clustering criteria. As a second step, we introduced bounding boxes for the accepted seed candidate, clustered all the overlapping cubes, and examined. After the FP reduction step, the average number of FPs per case was estimated to be 2.47 per DBT volume with a sensitivity of 83.3%.

  8. A ROC-based feature selection method for computer-aided detection and diagnosis

    Science.gov (United States)

    Wang, Songyuan; Zhang, Guopeng; Liao, Qimei; Zhang, Junying; Jiao, Chun; Lu, Hongbing

    2014-03-01

    Image-based computer-aided detection and diagnosis (CAD) has been a very active research topic aiming to assist physicians to detect lesions and distinguish them from benign to malignant. However, the datasets fed into a classifier usually suffer from small number of samples, as well as significantly less samples available in one class (have a disease) than the other, resulting in the classifier's suboptimal performance. How to identifying the most characterizing features of the observed data for lesion detection is critical to improve the sensitivity and minimize false positives of a CAD system. In this study, we propose a novel feature selection method mR-FAST that combines the minimal-redundancymaximal relevance (mRMR) framework with a selection metric FAST (feature assessment by sliding thresholds) based on the area under a ROC curve (AUC) generated on optimal simple linear discriminants. With three feature datasets extracted from CAD systems for colon polyps and bladder cancer, we show that the space of candidate features selected by mR-FAST is more characterizing for lesion detection with higher AUC, enabling to find a compact subset of superior features at low cost.

  9. Computer-Aided Methodology for Syndromic Strabismus Diagnosis.

    Science.gov (United States)

    Sousa de Almeida, João Dallyson; Silva, Aristófanes Corrêa; Teixeira, Jorge Antonio Meireles; Paiva, Anselmo Cardoso; Gattass, Marcelo

    2015-08-01

    Strabismus is a pathology that affects approximately 4 % of the population, causing aesthetic problems reversible at any age and irreversible sensory alterations that modify the vision mechanism. The Hirschberg test is one type of examination for detecting this pathology. Computer-aided detection/diagnosis is being used with relative success to aid health professionals. Nevertheless, the routine use of high-tech devices for aiding ophthalmological diagnosis and therapy is not a reality within the subspecialty of strabismus. Thus, this work presents a methodology to aid in diagnosis of syndromic strabismus through digital imaging. Two hundred images belonging to 40 patients previously diagnosed by an specialist were tested. The method was demonstrated to be 88 % accurate in esotropias identification (ET), 100 % for exotropias (XT), 80.33 % for hypertropias (HT), and 83.33 % for hypotropias (HoT). The overall average error was 5.6Δ and 3.83Δ for horizontal and vertical deviations, respectively, against the measures presented by the specialist.

  10. Parameter optimization of a computer-aided diagnosis scheme for the segmentation of microcalcification clusters in mammograms

    International Nuclear Information System (INIS)

    Gavrielides, Marios A.; Lo, Joseph Y.; Floyd, Carey E. Jr.

    2002-01-01

    Our purpose in this study is to develop a parameter optimization technique for the segmentation of suspicious microcalcification clusters in digitized mammograms. In previous work, a computer-aided diagnosis (CAD) scheme was developed that used local histogram analysis of overlapping subimages and a fuzzy rule-based classifier to segment individual microcalcifications, and clustering analysis for reducing the number of false positive clusters. The performance of this previous CAD scheme depended on a large number of parameters such as the intervals used to calculate fuzzy membership values and on the combination of membership values used by each decision rule. These parameters were optimized empirically based on the performance of the algorithm on the training set. In order to overcome the limitations of manual training and rule generation, the segmentation algorithm was modified in order to incorporate automatic parameter optimization. For the segmentation of individual microcalcifications, the new algorithm used a neural network with fuzzy-scaled inputs. The fuzzy-scaled inputs were created by processing the histogram features with a family of membership functions, the parameters of which were automatically extracted from the distribution of the feature values. The neural network was trained to classify feature vectors as either positive or negative. Individual microcalcifications were segmented from positive subimages. After clustering, another neural network was trained to eliminate false positive clusters. A database of 98 images provided training and testing sets to optimize the parameters and evaluate the CAD scheme, respectively. The performance of the algorithm was evaluated with a FROC analysis. At a sensitivity rate of 93.2%, there was an average of 0.8 false positive clusters per image. The results are very comparable with those taken using our previously published rule-based method. However, the new algorithm is more suited to generalize its

  11. Computer-aided design and computer science technology

    Science.gov (United States)

    Fulton, R. E.; Voigt, S. J.

    1976-01-01

    A description is presented of computer-aided design requirements and the resulting computer science advances needed to support aerospace design. The aerospace design environment is examined, taking into account problems of data handling and aspects of computer hardware and software. The interactive terminal is normally the primary interface between the computer system and the engineering designer. Attention is given to user aids, interactive design, interactive computations, the characteristics of design information, data management requirements, hardware advancements, and computer science developments.

  12. Lung nodule detection on chest CT: evaluation of a computer-aided detection (CAD) system

    International Nuclear Information System (INIS)

    Lee, In Jae; Gamsu, Gordon; Czum, Julianna; Johnson, Rebecca; Chakrapani, Sanjay; Wu, Ning

    2005-01-01

    To evaluate the capacity of a computer-aided detection (CAD) system to detect lung nodules in clinical chest CT. A total of 210 consecutive clinical chest CT scans and their reports were reviewed by two chest radiologists and 70 were selected (33 without nodules and 37 with 1-6 nodules, 4-15.4 mm in diameter). The CAD system (ImageChecker CT LN-1000) developed by R2 Technology, Inc. (Sunnyvale, CA) was used. Its algorithm was designed to detect nodules with a diameter of 4-20 mm. The two chest radiologists working with the CAD system detected a total of 78 nodules. These 78 nodules form the database for this study. Four independent observers interpreted the studies with and without the CAD system. The detection rates of the four independent observers without CAD were 81% (63/78), 85% (66/78), 83% (65/78), and 83% (65/78), respectively. With CAD their rates were 87% (68/78), 85% (66/78), 86% (67/78), and 85% (66/78), respectively. The differences between these two sets of detection rates did not reach statistical significance. In addition, CAD detected eight nodules that were not mentioned in the original clinical radiology reports. The CAD system produced 1.56 false-positive nodules per CT study. The four test observers had 0, 0.1, 0.17, and 0.26 false-positive results per study without CAD and 0.07, 0.2, 0.23, and 0.39 with CAD, respectively. The CAD system can assist radiologists in detecting pulmonary nodules in chest CT, but with a potential increase in their false positive rates. Technological improvements to the system could increase the sensitivity and specificity for the detection of pulmonary nodules and reduce these false-positive results

  13. Computer-aided detection of basal cell carcinoma through blood content analysis in dermoscopy images

    Science.gov (United States)

    Kharazmi, Pegah; Kalia, Sunil; Lui, Harvey; Wang, Z. Jane; Lee, Tim K.

    2018-02-01

    Basal cell carcinoma (BCC) is the most common type of skin cancer, which is highly damaging to the skin at its advanced stages and causes huge costs on the healthcare system. However, most types of BCC are easily curable if detected at early stage. Due to limited access to dermatologists and expert physicians, non-invasive computer-aided diagnosis is a viable option for skin cancer screening. A clinical biomarker of cancerous tumors is increased vascularization and excess blood flow. In this paper, we present a computer-aided technique to differentiate cancerous skin tumors from benign lesions based on vascular characteristics of the lesions. Dermoscopy image of the lesion is first decomposed using independent component analysis of the RGB channels to derive melanin and hemoglobin maps. A novel set of clinically inspired features and ratiometric measurements are then extracted from each map to characterize the vascular properties and blood content of the lesion. The feature set is then fed into a random forest classifier. Over a dataset of 664 skin lesions, the proposed method achieved an area under ROC curve of 0.832 in a 10-fold cross validation for differentiating basal cell carcinomas from benign lesions.

  14. Effect of computer-aided detection as a second reader in multidetector-row CT colonography

    International Nuclear Information System (INIS)

    Mang, Thomas; Peloschek, Philipp; Plank, Christina; Maier, Andrea; Weber, Michael; Herold, Christian; Schima, Wolfgang; Graser, Anno; Bogoni, Luca

    2007-01-01

    Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscopically confirmed polyps ≥0.5 cm, seven cancers; 15 patients: no abnormalities) were retrospectively reviewed by four radiologists (two expert, two nonexpert). After primary data evaluation, a second reading augmented with findings of CAD (polyp-enhanced view, Siemens) was performed. Sensitivities and reading time were calculated for each reader without CAD and supported by CAD findings. The sensitivity of expert readers was 91% each, and of nonexpert readers, 76% and 75%, respectively, for polyp detection. CAD increased the sensitivity of expert readers to 96% (P = 0.25) and 93% (P = 1), and that of nonexpert readers to 91% (P = 0.008) and 95% (P = 0.001), respectively. All four readers diagnosed 100% of cancers, but CAD alone only 43%. CAD increased reading time by 2.1 min (mean). CAD as a second reader significantly improves sensitivity for polyp detection in a high disease prevalence population for nonexpert readers. CAD causes a modest increase in reading time. CAD is of limited value in the detection of cancer. (orig.)

  15. A repeat-until-success quantum computing scheme

    Energy Technology Data Exchange (ETDEWEB)

    Beige, A [School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT (United Kingdom); Lim, Y L [DSO National Laboratories, 20 Science Park Drive, Singapore 118230, Singapore (Singapore); Kwek, L C [Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542, Singapore (Singapore)

    2007-06-15

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes.

  16. A repeat-until-success quantum computing scheme

    International Nuclear Information System (INIS)

    Beige, A; Lim, Y L; Kwek, L C

    2007-01-01

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes

  17. Analysis and minimization of overtraining effect in rule-based classifiers for computer-aided diagnosis

    International Nuclear Information System (INIS)

    Li Qiang; Doi Kunio

    2006-01-01

    Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists detect various lesions in medical images. In CAD schemes, classifiers play a key role in achieving a high lesion detection rate and a low false-positive rate. Although many popular classifiers such as linear discriminant analysis and artificial neural networks have been employed in CAD schemes for reduction of false positives, a rule-based classifier has probably been the simplest and most frequently used one since the early days of development of various CAD schemes. However, with existing rule-based classifiers, there are major disadvantages that significantly reduce their practicality and credibility. The disadvantages include manual design, poor reproducibility, poor evaluation methods such as resubstitution, and a large overtraining effect. An automated rule-based classifier with a minimized overtraining effect can overcome or significantly reduce the extent of the above-mentioned disadvantages. In this study, we developed an 'optimal' method for the selection of cutoff thresholds and a fully automated rule-based classifier. Experimental results performed with Monte Carlo simulation and a real lung nodule CT data set demonstrated that the automated threshold selection method can completely eliminate overtraining effect in the procedure of cutoff threshold selection, and thus can minimize overall overtraining effect in the constructed rule-based classifier. We believe that this threshold selection method is very useful in the construction of automated rule-based classifiers with minimized overtraining effect

  18. Application of a kernel-based online learning algorithm to the classification of nodule candidates in computer-aided detection of CT lung nodules

    International Nuclear Information System (INIS)

    Matsumoto, S.; Ohno, Y.; Takenaka, D.; Sugimura, K.; Yamagata, H.

    2007-01-01

    Classification of the nodule candidates in computer-aided detection (CAD) of lung nodules in CT images was addressed by constructing a nonlinear discriminant function using a kernel-based learning algorithm called the kernel recursive least-squares (KRLS) algorithm. Using the nodule candidates derived from the processing by a CAD scheme of 100 CT datasets containing 253 non-calcified nodules or 3 mm or larger as determined by the consensus of two thoracic radiologists, the following trial were carried out 100 times: by randomly selecting 50 datasets for training, a nonlinear discriminant function was obtained using the nodule candidates in the training datasets and tested with the remaining candidates; for comparison, a rule-based classification was tested in a similar manner. At the number of false positives per case of about 5, the nonlinear classification method showed an improved sensitivity of 80% (mean over the 100 trials) compared with 74% of the rule-based method. (orig.)

  19. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    Science.gov (United States)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  20. A Distributed Intrusion Detection Scheme about Communication Optimization in Smart Grid

    Directory of Open Access Journals (Sweden)

    Yunfa Li

    2013-01-01

    Full Text Available We first propose an efficient communication optimization algorithm in smart grid. Based on the optimization algorithm, we propose an intrusion detection algorithm to detect malicious data and possible cyberattacks. In this scheme, each node acts independently when it processes communication flows or cybersecurity threats. And neither special hardware nor nodes cooperation is needed. In order to justify the feasibility and the availability of this scheme, a series of experiments have been done. The results show that it is feasible and efficient to detect malicious data and possible cyberattacks with less computation and communication cost.

  1. Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules

    Science.gov (United States)

    Gong, Jing; Liu, Ji-Yu; Sun, Xi-Wen; Zheng, Bin; Nie, Sheng-Dong

    2018-02-01

    This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among them, 76 are benign, 81 are stage I and 86 are stage III malignant nodules. The cases are separated into three data sets involving: (1) all nodules, (2) benign and stage I malignant nodules, and (3) benign and stage III malignant nodules. A CADx scheme is applied to segment lung nodules depicted on computed tomography images and we initially computed 66 3D image features. Then, three machine learning models namely, a support vector machine, naïve Bayes classifier and linear discriminant analysis, are separately trained and tested by using three data sets and a leave-one-case-out cross-validation method embedded with a Relief-F feature selection algorithm. When separately using three data sets to train and test three classifiers, the average areas under receiver operating characteristic curves (AUC) are 0.94, 0.90 and 0.99, respectively. When using the classifiers trained using data sets with all nodules, average AUC values are 0.88 and 0.99 for detecting early and advanced stage nodules, respectively. AUC values computed from three classifiers trained using the same data set are consistent without statistically significant difference (p  >  0.05). This study demonstrates (1) the feasibility of applying a CADx scheme to accurately distinguish between benign and malignant lung nodules, and (2) a positive trend between CADx performance and cancer progression stage. Thus, in order to increase CADx performance in detecting subtle and early cancer, training data sets should include more diverse early stage cancer cases.

  2. Computer aided detection of clusters of microcalcifications on full field digital mammograms

    International Nuclear Information System (INIS)

    Ge Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.; Chan, H.-P.; Wei Jun; Helvie, Mark A.; Zhou Chuan

    2006-01-01

    We are developing a computer-aided detection (CAD) system to identify microcalcification clusters (MCCs) automatically on full field digital mammograms (FFDMs). The CAD system includes six stages: preprocessing; image enhancement; segmentation of microcalcification candidates; false positive (FP) reduction for individual microcalcifications; regional clustering; and FP reduction for clustered microcalcifications. At the stage of FP reduction for individual microcalcifications, a truncated sum-of-squares error function was used to improve the efficiency and robustness of the training of an artificial neural network in our CAD system for FFDMs. At the stage of FP reduction for clustered microcalcifications, morphological features and features derived from the artificial neural network outputs were extracted from each cluster. Stepwise linear discriminant analysis (LDA) was used to select the features. An LDA classifier was then used to differentiate clustered microcalcifications from FPs. A data set of 96 cases with 192 images was collected at the University of Michigan. This data set contained 96 MCCs, of which 28 clusters were proven by biopsy to be malignant and 68 were proven to be benign. The data set was separated into two independent data sets for training and testing of the CAD system in a cross-validation scheme. When one data set was used to train and validate the convolution neural network (CNN) in our CAD system, the other data set was used to evaluate the detection performance. With the use of a truncated error metric, the training of CNN could be accelerated and the classification performance was improved. The CNN in combination with an LDA classifier could substantially reduce FPs with a small tradeoff in sensitivity. By using the free-response receiver operating characteristic methodology, it was found that our CAD system can achieve a cluster-based sensitivity of 70, 80, and 90 % at 0.21, 0.61, and 1.49 FPs/image, respectively. For case

  3. Analytical evaluation of computer-based decision aids

    International Nuclear Information System (INIS)

    Kisner, R.A.

    1985-01-01

    This paper introduces a method for evaluating decision aids for nuclear power plant operators. The method involves a two-stage process of classification and analytical evaluation of display form and content. The classification scheme relates each specific aid to one or more general decision-making tasks. Evaluation then proceeds using a normative top-down design process based on the classification scheme by determining or deducing how various design issues associated with this process were resolved by the designer. The result is an assessment of the ''understandability'' of the aid as well as identification of the training and display features necessary to ensure understandability. 7 refs., 4 figs., 1 tab

  4. [Computer-aided Prognosis for Breast Cancer Based on Hematoxylin & Eosin Histopathology Image].

    Science.gov (United States)

    Chen, Jiamei; Qu, Aiping; Liu, Wenlou; Wang, Linwei; Yuan, Jingping; Liu, Juan; Li, Yan

    2016-06-01

    Quantitatively analyzing hematoxylin &eosin(H&E)histopathology images is an emerging field attracting increasing attentions in recent years.This paper reviews the application of computer-aided image analysis in breast cancer prognosis.The traditional prognosis based on H&E histopathology image for breast cancer is firstly sketched,followed by a detailed description of the workflow of computer-aided prognosis including image acquisition,image preprocessing,regions of interest detection and object segmentation,feature extraction,and computer-aided prognosis.In the end,major technical challenges and future directions in this field are summarized.

  5. Improved cancer detection in automated breast ultrasound by radiologists using Computer Aided Detection

    International Nuclear Information System (INIS)

    Zelst, J.C.M. van; Tan, T.; Platel, B.; Jong, M. de; Steenbakkers, A.; Mourits, M.; Grivegnee, A.; Borelli, C.; Karssemeijer, N.; Mann, R.M.

    2017-01-01

    Objective: To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. Methods: 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n = 40) with >1 year of follow up, benign (n = 30) lesions that were either biopsied or remained stable, and malignant lesions (n = 20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Results: Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p = 0.001). Sensitivity of all readers improved (range 5.2–10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4–5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Conclusions: Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer.

  6. Improved cancer detection in automated breast ultrasound by radiologists using Computer Aided Detection

    Energy Technology Data Exchange (ETDEWEB)

    Zelst, J.C.M. van, E-mail: Jan.vanZelst@radboudumc.nl [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Tan, T.; Platel, B. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Jong, M. de [Jeroen Bosch Medical Centre, Department of Radiology, ‘s-Hertogenbosch (Netherlands); Steenbakkers, A. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Mourits, M. [Jeroen Bosch Medical Centre, Department of Radiology, ‘s-Hertogenbosch (Netherlands); Grivegnee, A. [Jules Bordet Institute, Department of Radiology, Brussels (Belgium); Borelli, C. [Catholic University of the Sacred Heart, Department of Radiological Sciences, Rome (Italy); Karssemeijer, N.; Mann, R.M. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands)

    2017-04-15

    Objective: To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. Methods: 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n = 40) with >1 year of follow up, benign (n = 30) lesions that were either biopsied or remained stable, and malignant lesions (n = 20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Results: Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p = 0.001). Sensitivity of all readers improved (range 5.2–10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4–5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Conclusions: Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer.

  7. Reproducibility of prompts in computer-aided detection (CAD) of breast cancer

    International Nuclear Information System (INIS)

    Taylor, C.G.; Champness, J.; Reddy, M.; Taylor, P.; Potts, H.W.W.; Given-Wilson, R.

    2003-01-01

    AIM: We evaluated the reproducibility of prompts using the R2 ImageChecker M2000 computer-aided detection (CAD) system. MATERIALS AND METHODS: Forty selected two-view mammograms of women with breast cancer were digitized and analysed using the ImageChecker on 10 separate occasions. The mammograms were chosen to provide both straightforward and subtle signs of malignancy. Data analysed included mammographic abnormality, pathology, and whether the cancer was prompted or given an emphasized prompt. RESULTS: Correct prompts were generated in 86 out of 100 occasions for screen-detected cancers. Reproducibility was less in the other categories of more subtle cancers: 21% for cancers previously missed by CAD, a group that contained more grade 1 and small (<10 mm) tumours. Prompts for calcifications were more reproducible than those for masses (76% versus 53%) and these cancers were more likely to have an emphasized prompt. CONCLUSIONS: Probably the most important cause of variability of prompts is shifts in film position between sequential digitizations. Consequently subtle lesions that are only just above the threshold for display may not be prompted on repeat scanning. However, users of CAD should be aware that even emphasized prompts are not consistently reproducible

  8. Computer aided detection of ureteral stones in thin slice computed tomography volumes using Convolutional Neural Networks.

    Science.gov (United States)

    Längkvist, Martin; Jendeberg, Johan; Thunberg, Per; Loutfi, Amy; Lidén, Mats

    2018-06-01

    Computed tomography (CT) is the method of choice for diagnosing ureteral stones - kidney stones that obstruct the ureter. The purpose of this study is to develop a computer aided detection (CAD) algorithm for identifying a ureteral stone in thin slice CT volumes. The challenge in CAD for urinary stones lies in the similarity in shape and intensity of stones with non-stone structures and how to efficiently deal with large high-resolution CT volumes. We address these challenges by using a Convolutional Neural Network (CNN) that works directly on the high resolution CT volumes. The method is evaluated on a large data base of 465 clinically acquired high-resolution CT volumes of the urinary tract with labeling of ureteral stones performed by a radiologist. The best model using 2.5D input data and anatomical information achieved a sensitivity of 100% and an average of 2.68 false-positives per patient on a test set of 88 scans. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Computer-Aided Facilities Management Systems (CAFM).

    Science.gov (United States)

    Cyros, Kreon L.

    Computer-aided facilities management (CAFM) refers to a collection of software used with increasing frequency by facilities managers. The six major CAFM components are discussed with respect to their usefulness and popularity in facilities management applications: (1) computer-aided design; (2) computer-aided engineering; (3) decision support…

  10. The effect of hearing aid signal-processing schemes on acceptable noise levels: perception and prediction.

    Science.gov (United States)

    Wu, Yu-Hsiang; Stangl, Elizabeth

    2013-01-01

    The acceptable noise level (ANL) test determines the maximum noise level that an individual is willing to accept while listening to speech. The first objective of the present study was to systematically investigate the effect of wide dynamic range compression processing (WDRC), and its combined effect with digital noise reduction (DNR) and directional processing (DIR), on ANL. Because ANL represents the lowest signal-to-noise ratio (SNR) that a listener is willing to accept, the second objective was to examine whether the hearing aid output SNR could predict aided ANL across different combinations of hearing aid signal-processing schemes. Twenty-five adults with sensorineural hearing loss participated in the study. ANL was measured monaurally in two unaided and seven aided conditions, in which the status of the hearing aid processing schemes (enabled or disabled) and the location of noise (front or rear) were manipulated. The hearing aid output SNR was measured for each listener in each condition using a phase-inversion technique. The aided ANL was predicted by unaided ANL and hearing aid output SNR, under the assumption that the lowest acceptable SNR at the listener's eardrum is a constant across different ANL test conditions. Study results revealed that, on average, WDRC increased (worsened) ANL by 1.5 dB, while DNR and DIR decreased (improved) ANL by 1.1 and 2.8 dB, respectively. Because the effects of WDRC and DNR on ANL were opposite in direction but similar in magnitude, the ANL of linear/DNR-off was not significantly different from that of WDRC/DNR-on. The results further indicated that the pattern of ANL change across different aided conditions was consistent with the pattern of hearing aid output SNR change created by processing schemes. Compared with linear processing, WDRC creates a noisier sound image and makes listeners less willing to accept noise. However, this negative effect on noise acceptance can be offset by DNR, regardless of microphone mode

  11. Nodule detection by chest X-ray and evaluation of computer-aided detection (CAD) software using an originally developed phantom for instructional purposes

    International Nuclear Information System (INIS)

    Nitta, Norihisa; Takahashi, Masashi; Takazakura, Ryutaro

    2006-01-01

    Chest X-ray and computed tomography (CT) are indispensable modalities for lung cancer examinations. CT technologies have dramatically improved and small nodules and obscure shadows have been detected more frequently. The new generation of radiologists feels that chest X-rays are not as useful as chest CT. Experiments using a newly-developed chest phantom were conducted to reconfirm blind spots in chest X-rays. Recent technological advances and high-definition capability have made chest X-rays more useful than ever. Even though development of multi-detector CT (MDCT) has facilitated detection of nodules, it has conversely incurred a problem of increasing data for analysis, taking tremendous time and effort. Here, employing a chest phantom and clinical samples, we evaluated the utility of two kinds of computer-aided detection (CAD) software (Image Checker CT and LungCARE NEV) as well as GGO CAD software that we have developed. More development of chest CT diagnostic software is urgently needed. (author)

  12. Computer-aided detection of pulmonary embolism at CT pulmonary angiography: can it improve performance of inexperienced readers?

    International Nuclear Information System (INIS)

    Blackmon, Kevin N.; McCain, Joshua W.; Koonce, James D.; Costello, Philip; Florin, Charles; Bogoni, Luca; Salganicoff, Marcos; Lee, Heon; Bastarrika, Gorka; Thilo, Christian; Joseph Schoepf, U.

    2011-01-01

    To evaluate the effect of a computer-aided detection (CAD) algorithm on the performance of novice readers for detection of pulmonary embolism (PE) at CT pulmonary angiography (CTPA). We included CTPA examinations of 79 patients (50 female, 52 ± 18 years). Studies were evaluated by two independent inexperienced readers who marked all vessels containing PE. After 3 months all studies were reevaluated by the same two readers, this time aided by CAD prototype. A consensus read by three expert radiologists served as the reference standard. Statistical analysis used χ 2 and McNemar testing. Expert consensus revealed 119 PEs in 32 studies. For PE detection, the sensitivity of CAD alone was 78%. Inexperienced readers' initial interpretations had an average per-PE sensitivity of 50%, which improved to 71% (p < 0.001) with CAD as a second reader. False positives increased from 0.18 to 0.25 per study (p = 0.03). Per-study, the readers initially detected 27/32 positive studies (84%); with CAD this number increased to 29.5 studies (92%; p = 0.125). Our results suggest that CAD significantly improves the sensitivity of PE detection for inexperienced readers with a small but appreciable increase in the rate of false positives. (orig.)

  13. Computer-aided detection of pulmonary embolism at CT pulmonary angiography: can it improve performance of inexperienced readers?

    Energy Technology Data Exchange (ETDEWEB)

    Blackmon, Kevin N.; McCain, Joshua W.; Koonce, James D.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Florin, Charles; Bogoni, Luca; Salganicoff, Marcos [Siemens AG, H IM SYNGO CAD Research and Development, Malvern, PA (United States); Lee, Heon [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Seoul Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bastarrika, Gorka [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Navarra, Department of Radiology, Pamplona (Spain); Thilo, Christian; Joseph Schoepf, U. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States)

    2011-06-15

    To evaluate the effect of a computer-aided detection (CAD) algorithm on the performance of novice readers for detection of pulmonary embolism (PE) at CT pulmonary angiography (CTPA). We included CTPA examinations of 79 patients (50 female, 52 {+-} 18 years). Studies were evaluated by two independent inexperienced readers who marked all vessels containing PE. After 3 months all studies were reevaluated by the same two readers, this time aided by CAD prototype. A consensus read by three expert radiologists served as the reference standard. Statistical analysis used {chi}{sup 2} and McNemar testing. Expert consensus revealed 119 PEs in 32 studies. For PE detection, the sensitivity of CAD alone was 78%. Inexperienced readers' initial interpretations had an average per-PE sensitivity of 50%, which improved to 71% (p < 0.001) with CAD as a second reader. False positives increased from 0.18 to 0.25 per study (p = 0.03). Per-study, the readers initially detected 27/32 positive studies (84%); with CAD this number increased to 29.5 studies (92%; p = 0.125). Our results suggest that CAD significantly improves the sensitivity of PE detection for inexperienced readers with a small but appreciable increase in the rate of false positives. (orig.)

  14. Computer-aided detection of renal calculi from noncontrast CT images using TV-flow and MSER features

    Science.gov (United States)

    Liu, Jianfei; Wang, Shijun; Turkbey, Evrim B.; Linguraru, Marius George; Yao, Jianhua; Summers, Ronald M.

    2015-01-01

    Purpose: Renal calculi are common extracolonic incidental findings on computed tomographic colonography (CTC). This work aims to develop a fully automated computer-aided diagnosis system to accurately detect renal calculi on CTC images. Methods: The authors developed a total variation (TV) flow method to reduce image noise within the kidneys while maintaining the characteristic appearance of renal calculi. Maximally stable extremal region (MSER) features were then calculated to robustly identify calculi candidates. Finally, the authors computed texture and shape features that were imported to support vector machines for calculus classification. The method was validated on a dataset of 192 patients and compared to a baseline approach that detects calculi by thresholding. The authors also compared their method with the detection approaches using anisotropic diffusion and nonsmoothing. Results: At a false positive rate of 8 per patient, the sensitivities of the new method and the baseline thresholding approach were 69% and 35% (p < 1e − 3) on all calculi from 1 to 433 mm3 in the testing dataset. The sensitivities of the detection methods using anisotropic diffusion and nonsmoothing were 36% and 0%, respectively. The sensitivity of the new method increased to 90% if only larger and more clinically relevant calculi were considered. Conclusions: Experimental results demonstrated that TV-flow and MSER features are efficient means to robustly and accurately detect renal calculi on low-dose, high noise CTC images. Thus, the proposed method can potentially improve diagnosis. PMID:25563255

  15. Studies on computer-aided diagnosis systems for chest radiographs and mammograms (in Japanese)

    International Nuclear Information System (INIS)

    Hara, Takeshi

    2001-01-01

    This thesis describes computer-aided diagnosis (CAD) systems for chest radiographs and mammograms. Preprocessing and imaging processing methods for each CAD system include dynamic range compression and region segmentation technique. A new pattern recognition technique combines genetic algorithms with template matching methods to detect lung nodules. A genetic algorithm was employed to select the optimal shape of simulated nodular shadows to be compared with real lesions on digitized chest images. Detection performance was evaluated using 332 chest radiographs from the database of the Japanese Society of Radiological Technology. Our average true-positive rate was 72.8% with an average of 11 false-positive findings per image. A new detection method using high resolution digital images with 0.05 mm sampling is also proposed for the mammogram CAD system to detect very small microcalcifications. An automated classification method uses feature extraction based on fractal dimension analysis of masses. Using over 200 cases to evaluate the detection of mammographic masses and calcifications, the detection rate of masses and microcalcifications were 87% and 96% with 1.5 and 1.8 false-positive findings, respectively. The classification performance on benign vs malignant lesions, the Az values that were defined by the areas under the ROC curves derived from classification schemes of masses and microcalcifications were 0.84 and 0.89. To demonstrate the practicality of these CAD systems in a computer-network environment, we propose to use the mammogram CAD system via the Internet and WWW. A common gateway interface and server-client approach for the CAD system via the Internet will permit display of the CAD results on ordinary computers

  16. Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography

    International Nuclear Information System (INIS)

    Lee, Choong Wook; Seo, Joon Beom; Song, Jae-Woo; Kim, Mi-Young; Lee, Ha Young; Park, Yang Shin; Chae, Eun Jin; Jang, Yu Mi; Kim, Namkug; Krauss, Bernard

    2011-01-01

    To evaluate the sensitivity of computer-aided detection(CAD) and dual-energy software('Lung PBV', 'Lung Vessels') for detecting peripheral pulmonary embolism(PE). Between Jan-2007 and Jan-2008, 309 patients underwent dual-energy CT angiography(DECTA) for the evaluation of suspected PE. Among them, 37 patients were retrospectively selected; 21 with PE at segmental-or-below levels and 16 without PE according to clinical reports. A standard computer assisted detection (CAD) package and two new types of software('Lung PBV', 'Lung Vessels') were applied on a dedicated workstation. This resulted in four alternative tests for detecting PE: DECTA alone and DECTA with CAD, 'Lung Vessels' and 'Lung PBV'. Two radiologists independently read all cases at different reading sessions. Two thoracic radiologists set the reference standard by combining all information from DECTA and software. The sensitivity of detection for all, segmental and subsegmental-or-below PE were assessed. The reference standard contained 136 PE(segmental 65, subsegmental-or-below 71). With DECTA alone, the sensitivity of detection for all, segmental and subsegmental-or-below pulmonary arteries was 54.5%/73.7%/34.4%; DECTA with CAD, 57.8%/76.8%/37.9%; DECTA with 'Lung PBV', 61.1%/79.9%/41.4%; DECTA with 'Lung Vessels', 64.0%/78.3%/48.5% respectively. The use of CAD, Lung Vessels and Lung PBV shows improved capability to detect peripheral PE. (orig.)

  17. Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography

    Science.gov (United States)

    Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2013-01-01

    OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418

  18. Computer-aided detection of bladder wall thickening in CT urography (CTU)

    Science.gov (United States)

    Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon Z.; Gordon, Marshall N.; Samala, Ravi K.

    2018-02-01

    We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). Bladder wall thickening is a manifestation of bladder cancer and its detection is more challenging than the detection of bladder masses. We first segmented the inner and outer bladder walls using our method that combined deep-learning convolutional neural network with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensity-projection-based method. The non-contrast region was smoothed and gray level threshold was applied to the contrast and non-contrast regions separately to extract the bladder wall and potential lesions. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify regions of wall thickening candidates. Volume-based features of the wall thickening candidates were analyzed with linear discriminant analysis (LDA) to differentiate bladder wall thickenings from false positives. A data set of 112 patients, 87 with wall thickening and 25 with normal bladders, was collected retrospectively with IRB approval, and split into independent training and test sets. Of the 57 training cases, 44 had bladder wall thickening and 13 were normal. Of the 55 test cases, 43 had wall thickening and 12 were normal. The LDA classifier was trained with the training set and evaluated with the test set. FROC analysis showed that the system achieved sensitivities of 93.2% and 88.4% for the training and test sets, respectively, at 0.5 FPs/case.

  19. A new and fast image feature selection method for developing an optimal mammographic mass detection scheme.

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    Selecting optimal features from a large image feature pool remains a major challenge in developing computer-aided detection (CAD) schemes of medical images. The objective of this study is to investigate a new approach to significantly improve efficacy of image feature selection and classifier optimization in developing a CAD scheme of mammographic masses. An image dataset including 1600 regions of interest (ROIs) in which 800 are positive (depicting malignant masses) and 800 are negative (depicting CAD-generated false positive regions) was used in this study. After segmentation of each suspicious lesion by a multilayer topographic region growth algorithm, 271 features were computed in different feature categories including shape, texture, contrast, isodensity, spiculation, local topological features, as well as the features related to the presence and location of fat and calcifications. Besides computing features from the original images, the authors also computed new texture features from the dilated lesion segments. In order to select optimal features from this initial feature pool and build a highly performing classifier, the authors examined and compared four feature selection methods to optimize an artificial neural network (ANN) based classifier, namely: (1) Phased Searching with NEAT in a Time-Scaled Framework, (2) A sequential floating forward selection (SFFS) method, (3) A genetic algorithm (GA), and (4) A sequential forward selection (SFS) method. Performances of the four approaches were assessed using a tenfold cross validation method. Among these four methods, SFFS has highest efficacy, which takes 3%-5% of computational time as compared to GA approach, and yields the highest performance level with the area under a receiver operating characteristic curve (AUC) = 0.864 ± 0.034. The results also demonstrated that except using GA, including the new texture features computed from the dilated mass segments improved the AUC results of the ANNs optimized

  20. Accuracy of detecting stenotic changes on coronary cineangiograms using computer image processing

    International Nuclear Information System (INIS)

    Sugahara, Tetsuo; Kimura, Koji; Maeda, Hirofumi.

    1990-01-01

    To accurately interprets stenotic changes on coronary cineangiograms, an automatic method of detecting stenotic lesion using computer image processing was developed. First, tracing of artery was performed. The vessel edges were then determined by unilateral Gaussian fitting. The stenotic change was detected on the basis of the reference diameter estimated by Hough transformation. This method was evaluated in 132 segments of 27 arteries in 18 patients. Three observers carried out visual interpretation and computer-aided interpretation. The rate of detection by visual interpretation was 6.1, 28.8 and 20.5%, and by computer-aided interpretation, 39.4, 39.4 and 45.5%. With computer-aided interpretation, the agreement between any two observers on lesions and non-lesions was 40.2% and 59.8%, respectively. Therefore, visual interpretation tended to underestimate the stenotic changes on coronary cineangiograms. We think that computer-aided interpretation increase the reliability of diagnosis on coronary cineangiograms. (author)

  1. Improved mammographic interpretation of masses using computer-aided diagnosis

    International Nuclear Information System (INIS)

    Leichter, I.; Fields, S.; Novak, B.; Nirel, R.; Bamberger, P.; Lederman, R.; Buchbinder, S.

    2000-01-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p z ) increased significantly (p z for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that of the unassisted radiologist. Our findings suggest that objective quantitative features extracted from digitized mammographic findings may help in differentiating between benign and malignant masses, and can assist the radiologist in the interpretation of mass lesions. (orig.)

  2. Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns

    NARCIS (Netherlands)

    Lohbauer, Ulrich; Belli, Renan; Cune, Marco S; Schepke, Ulf

    2017-01-01

    Today, a substantial part of the dental crown production uses computer-aided design and computer-aided manufacturing (CAD/CAM) technology. A recent step in restorative dentistry is the replacement of natural tooth structure with pre-polymerized and machined resin-based methacrylic polymers.

  3. Automatic epileptic seizure detection in EEGs using MF-DFA, SVM based on cloud computing.

    Science.gov (United States)

    Zhang, Zhongnan; Wen, Tingxi; Huang, Wei; Wang, Meihong; Li, Chunfeng

    2017-01-01

    Epilepsy is a chronic disease with transient brain dysfunction that results from the sudden abnormal discharge of neurons in the brain. Since electroencephalogram (EEG) is a harmless and noninvasive detection method, it plays an important role in the detection of neurological diseases. However, the process of analyzing EEG to detect neurological diseases is often difficult because the brain electrical signals are random, non-stationary and nonlinear. In order to overcome such difficulty, this study aims to develop a new computer-aided scheme for automatic epileptic seizure detection in EEGs based on multi-fractal detrended fluctuation analysis (MF-DFA) and support vector machine (SVM). New scheme first extracts features from EEG by MF-DFA during the first stage. Then, the scheme applies a genetic algorithm (GA) to calculate parameters used in SVM and classify the training data according to the selected features using SVM. Finally, the trained SVM classifier is exploited to detect neurological diseases. The algorithm utilizes MLlib from library of SPARK and runs on cloud platform. Applying to a public dataset for experiment, the study results show that the new feature extraction method and scheme can detect signals with less features and the accuracy of the classification reached up to 99%. MF-DFA is a promising approach to extract features for analyzing EEG, because of its simple algorithm procedure and less parameters. The features obtained by MF-DFA can represent samples as well as traditional wavelet transform and Lyapunov exponents. GA can always find useful parameters for SVM with enough execution time. The results illustrate that the classification model can achieve comparable accuracy, which means that it is effective in epileptic seizure detection.

  4. Fate of pulmonary nodules detected by computer-aided diagnosis and physician review on the computed tomography simulation images for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Park, Hyo Jung; Kim, Jin Sung; Park, Hee Chul; Oh, Dong Ryul

    2014-01-01

    To investigate the frequency and clinical significance of detected incidental lung nodules found on computed tomography (CT) simulation images for hepatocellular carcinoma (HCC) using computer-aided diagnosis (CAD) and a physician review. Sixty-seven treatment-naive HCC patients treated with transcatheter arterial chemoembolization and radiotherapy (RT) were included for the study. Portal phase of simulation CT images was used for CAD analysis and a physician review for lung nodule detection. For automated nodule detection, a commercially available CAD system was used. To assess the performance of lung nodule detection for lung metastasis, the sensitivity, negative predictive value (NPV), and positive predictive value (PPV) were calculated. Forty-six patients had incidental nodules detected by CAD with a total of 109 nodules. Only 20 (18.3%) nodules were considered to be significant nodules by a physician review. The number of significant nodules detected by both of CAD or a physician review was 24 in 9 patients. Lung metastases developed in 11 of 46 patients who had any type of nodule. The sensitivities were 58.3% and 100% based on patient number and on the number of nodules, respectively. The NPVs were 91.4% and 100%, respectively. And the PPVs were 77.8% and 91.7%, respectively. Incidental detection of metastatic nodules was not an uncommon event. From our study, CAD could be applied to CT simulation images allowing for an increase in detection of metastatic nodules.

  5. Computer-Aided Modeling Framework

    DEFF Research Database (Denmark)

    Fedorova, Marina; Sin, Gürkan; Gani, Rafiqul

    Models are playing important roles in design and analysis of chemicals based products and the processes that manufacture them. Computer-aided methods and tools have the potential to reduce the number of experiments, which can be expensive and time consuming, and there is a benefit of working...... development and application. The proposed work is a part of the project for development of methods and tools that will allow systematic generation, analysis and solution of models for various objectives. It will use the computer-aided modeling framework that is based on a modeling methodology, which combines....... In this contribution, the concept of template-based modeling is presented and application is highlighted for the specific case of catalytic membrane fixed bed models. The modeling template is integrated in a generic computer-aided modeling framework. Furthermore, modeling templates enable the idea of model reuse...

  6. Computer-aided detection in CT colonography: initial clinical experience using a prototype system

    International Nuclear Information System (INIS)

    Graser, A.; Geisbuesch, S.; Reiser, M.F.; Becker, C.R.; Kolligs, F.T.; Schaefer, C.; Mang, T.

    2007-01-01

    Computer-aided detection (CAD) algorithms help to detect colonic polyps at CT colonography (CTC). The purpose of this study was to evaluate the accuracy of CAD versus an expert reader in CTC. One hundred forty individuals (67 men, 73 women; mean age, 59 years) underwent screening 64-MDCT colonography after full cathartic bowel cleansing without fecal tagging. One expert reader interpreted supine and prone scans using a 3D workstation with integrated CAD used as ''second reader.'' The system's sensitivity for the detection of polyps, the number of false-positive findings, and its running time were evaluated. Polyps were classified as small (≤5 mm), medium (6-9 mm), and large (≥10 mm). A total of 118 polyps (small, 85; medium, 19; large, 14) were found in 56 patients. CAD detected 72 polyps (61%) with an average of 2.2 false-positives. Sensitivity was 51% (43/85) for small, 90% (17/19) for medium, and 86% (12/14) for large polyps. For all polyps, per-patient sensitivity was 89% (50/56) for the radiologist and 73% (41/56) for CAD. For large and medium polyps, per-patient sensitivity was 100% for the radiologist, and 96% for CAD. In conclusion, CAD shows high sensitivity in the detection of clinically significant polyps with acceptable false-positive rates. (orig.)

  7. Computer-aided-detection marker value and breast density in the detection of invasive lobular carcinoma

    International Nuclear Information System (INIS)

    Destounis, Stamatia; Hanson, Sarah; Roehrig, Jimmy

    2007-01-01

    Invasive Lobular Carcinoma (ILC) is frequently a mammographic and diagnostic dilemma; thus any additional information that CAD (Computer-Aided Detection) systems can give radiologists may be helpful. Our study was to evaluate the role of CAD numeric values as indicators of malignancy and the effect of breast density in the diagnosis of ILC. Eighty consecutive biopsy-proven ILC cases with CAD (ImageChecker registered , Hologic vertical stroke R2, Santa Clara, CA, versions 2.3, 3.1, 3.2, 5.0, 5.2) diagnosed between June 2002 and December 2004 were retrospectively reviewed. Data included: BIRADS registered breast density, whether CAD marked the cancer at diagnosis year or years prior, and lesion type. Study mammograms underwent additional CAD scans (Image Checker registered V5.3, V8.0, V8.1) to obtain a numeric value associated with each marker, low values represent increasingly suspicious features. CAD correctly marked 65% (52/80) of ILC cases, detection was found to decrease with increased breast density. Numeric values of CAD marks at sites of carcinoma showed median score of 171 (range 0 - 1121). The CAD marker may potentially be used as an additional indicator of suspicious lesion features in all breast densities and higher likelihood that an area on the mammogram requires further investigation. (orig.)

  8. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur; Yaroshenko, Andre; Velroyen, Astrid

    2015-01-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering...... properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists...... of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually...

  9. Developing a coding scheme for detecting usability and fun problems in computer games for young children

    NARCIS (Netherlands)

    Barendregt, W.; Bekker, M.M.

    2006-01-01

    This article describes the development and assessment of a coding scheme for finding both usability and fun problems through observations of young children playing computer games during user tests. The proposed coding scheme is based on an existing list of breakdown indication types of the detailed

  10. Computer-aided pulmonary nodule detection. Performance of two CAD systems at different CT dose levels

    International Nuclear Information System (INIS)

    Hein, Patrick Alexander; Rogalla, P.; Klessen, C.; Lembcke, A.; Romano, V.C.

    2009-01-01

    Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120kV tube voltage (1 mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median also positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p>0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems. (orig.)

  11. Computer-aided detection as a decision assistant in chest radiography

    Science.gov (United States)

    Samulski, Maurice R. M.; Snoeren, Peter R.; Platel, Bram; van Ginneken, Bram; Hogeweg, Laurens; Schaefer-Prokop, Cornelia; Karssemeijer, Nico

    2011-03-01

    Background. Contrary to what may be expected, finding abnormalities in complex images like pulmonary nodules in chest radiographs is not dominated by time-consuming search strategies but by an almost immediate global interpretation. This was already known in the nineteen-seventies from experiments with briefly flashed chest radiographs. Later on, experiments with eye-trackers showed that abnormalities attracted the attention quite fast but often without further reader actions. Prolonging one's search seldom leads to newly found abnormalities and may even increase the chance of errors. The problem of reading chest radiographs is therefore not dominated by finding the abnormalities, but by interpreting them. Hypothesis. This suggests that readers could benefit from computer-aided detection (CAD) systems not so much by their ability to prompt potential abnormalities, but more from their ability to 'interpret' the potential abnormalities. In this paper, this hypothesis was investigated by an observer experiment. Experiment. In one condition, the traditional CAD condition, the most suspicious CAD locations were shown to the subjects, without telling them the levels of suspiciousness according to CAD. In the other condition, interactive CAD condition, levels of suspiciousness were given, but only when readers requested them at specified locations. These two conditions focus on decreasing search errors and decision errors, respectively. Results of reading without CAD were also recorded. Six subjects, all non-radiologists, read 223 chest radiographs in both conditions. CAD results were obtained from the OnGuard 5.0 system developed by Riverain Medical (Miamisburg, Ohio). Results. The observer data were analyzed by Location Response Operating Characteristic analysis (LROC). It was found that: 1) With the aid of CAD, the performance is significantly better than without CAD; 2) The performance with interactive CAD is significantly better than with traditional CAD at low false

  12. A dimension reduction strategy for improving the efficiency of computer-aided detection for CT colonography

    Science.gov (United States)

    Song, Bowen; Zhang, Guopeng; Wang, Huafeng; Zhu, Wei; Liang, Zhengrong

    2013-02-01

    Various types of features, e.g., geometric features, texture features, projection features etc., have been introduced for polyp detection and differentiation tasks via computer aided detection and diagnosis (CAD) for computed tomography colonography (CTC). Although these features together cover more information of the data, some of them are statistically highly-related to others, which made the feature set redundant and burdened the computation task of CAD. In this paper, we proposed a new dimension reduction method which combines hierarchical clustering and principal component analysis (PCA) for false positives (FPs) reduction task. First, we group all the features based on their similarity using hierarchical clustering, and then PCA is employed within each group. Different numbers of principal components are selected from each group to form the final feature set. Support vector machine is used to perform the classification. The results show that when three principal components were chosen from each group we can achieve an area under the curve of receiver operating characteristics of 0.905, which is as high as the original dataset. Meanwhile, the computation time is reduced by 70% and the feature set size is reduce by 77%. It can be concluded that the proposed method captures the most important information of the feature set and the classification accuracy is not affected after the dimension reduction. The result is promising and further investigation, such as automatically threshold setting, are worthwhile and are under progress.

  13. Computer-Aided Manufacturing of 3D Workpieces

    OpenAIRE

    Cornelia Victoria Anghel Drugarin; Mihaela Dorica Stroia

    2017-01-01

    Computer-Aided Manufacturing (CAM) assumes to use dedicated software for controlling machine tools and similar devices in the process of workpieces manufacturing. CAM is, in fact, an application technology that uses computer software and machinery to simplify and automate manufacturing processes. CAM is the inheritor of computer-aided engineering (CAE) and is often used conjunctively with computer-aided design (CAD). Advanced CAM solutions are forthcoming and have a large ...

  14. Three-class classification in computer-aided diagnosis of breast cancer by support vector machine

    Science.gov (United States)

    Sun, Xuejun; Qian, Wei; Song, Dansheng

    2004-05-01

    Design of classifier in computer-aided diagnosis (CAD) scheme of breast cancer plays important role to its overall performance in sensitivity and specificity. Classification of a detected object as malignant lesion, benign lesion, or normal tissue on mammogram is a typical three-class pattern recognition problem. This paper presents a three-class classification approach by using two-stage classifier combined with support vector machine (SVM) learning algorithm for classification of breast cancer on mammograms. The first classification stage is used to detect abnormal areas and normal breast tissues, and the second stage is for classification of malignant or benign in detected abnormal objects. A series of spatial, morphology and texture features have been extracted on detected objects areas. By using genetic algorithm (GA), different feature groups for different stage classification have been investigated. Computerized free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) analyses have been employed in different classification stages. Results have shown that obvious performance improvement in both sensitivity and specificity was observed through proposed classification approach compared with conventional two-class classification approaches, indicating its effectiveness in classification of breast cancer on mammograms.

  15. Detection Efficiency of Microcalcification using Computer Aided Diagnosis in the Breast Ultrasonography Images

    International Nuclear Information System (INIS)

    Lee, Jin Soo; Ko, Seong Jin; Kang, Se Sik; Kim, Jung Hoon; Choi, Seok Yoon; Kim, Chang Soo; Park, Hyung Hu

    2012-01-01

    Digital Mammography makes it possible to reproduce the entire breast image. And it is used to detect microcalcification and mass which are the most important point of view of nonpalpable early breast cancer, so it has been used as the primary screening test of breast disease. It is reported that microcalcification of breast lesion is important in diagnosis of early breast cancer. In this study, six types of texture features algorithms are used to detect microcalcification on breast US images and the study has analyzed recognition rate of lesion between normal US images and other US images which microcalification is seen. As a result of the experiment, Computer aided diagnosis recognition rate that distinguishes mammography and breast US disease was considerably high 70-98%. The average contrast and entropy parameters were low in ROC analysis, but sensitivity and specificity of four types parameters were over 90%. Therefore it is possible to detect microcalcification on US images. If not only six types of texture features algorithms but also the research of additional parameter algorithm is being continually proceeded and basis of practical use on CAD is being prepared, it can be a important meaning as pre-reading. Also, it is considered very useful things for early diagnosis of breast cancer.

  16. Potential contribution of multiplanar reconstruction (MPR) to computer-aided detection of lung nodules on MDCT

    International Nuclear Information System (INIS)

    Matsumoto, Sumiaki; Ohno, Yoshiharu; Yamagata, Hitoshi; Nogami, Munenobu; Kono, Atsushi; Sugimura, Kazuro

    2012-01-01

    Purpose: To evaluate potential benefits of using multiplanar reconstruction (MPR) in computer-aided detection (CAD) of lung nodules on multidetector computed tomography (MDCT). Materials and methods: MDCT datasets of 60 patients with suspected lung nodules were retrospectively collected. Using “second-read” CAD, two radiologists (Readers 1 and 2) independently interpreted these datasets for the detection of non-calcified nodules (≥4 mm) with concomitant confidence rating. They did this task twice, first without MPR (using only axial images), and then 4 weeks later with MPR (using also coronal and sagittal MPR images), where the total reading time per dataset, including the time taken to assess the detection results of CAD software (CAD assessment time), was recorded. The total reading time and CAD assessment time without MPR and those with MPR were statistically compared for each reader. The radiologists’ performance for detecting nodules without MPR and the performance with MPR were compared using jackknife free-response receiver operating characteristic (JAFROC) analysis. Results: Compared to the CAD assessment time without MPR (mean, 69 s and 57 s for Readers 1 and 2), the CAD assessment time with MPR (mean, 46 s and 45 s for Readers 1 and 2) was significantly reduced (P < 0.001). For Reader 1, the total reading time was also significantly shorter in the case with MPR. There was no significant difference between the detection performances without MPR and with MPR. Conclusion: The use of MPR has the potential to improve the workflow in CAD of lung nodules on MDCT.

  17. Automation of reliability evaluation procedures through CARE - The computer-aided reliability estimation program.

    Science.gov (United States)

    Mathur, F. P.

    1972-01-01

    Description of an on-line interactive computer program called CARE (Computer-Aided Reliability Estimation) which can model self-repair and fault-tolerant organizations and perform certain other functions. Essentially CARE consists of a repository of mathematical equations defining the various basic redundancy schemes. These equations, under program control, are then interrelated to generate the desired mathematical model to fit the architecture of the system under evaluation. The mathematical model is then supplied with ground instances of its variables and is then evaluated to generate values for the reliability-theoretic functions applied to the model.

  18. Computer-aided-detection marker value and breast density in the detection of invasive lobular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Destounis, Stamatia; Hanson, Sarah [The Elizabeth Wende Breast Clinic, Rochester, NY (United States); Roehrig, Jimmy [R2/Hologic, Inc., Santa Clara, CA (United States)

    2007-08-15

    Invasive Lobular Carcinoma (ILC) is frequently a mammographic and diagnostic dilemma; thus any additional information that CAD (Computer-Aided Detection) systems can give radiologists may be helpful. Our study was to evaluate the role of CAD numeric values as indicators of malignancy and the effect of breast density in the diagnosis of ILC. Eighty consecutive biopsy-proven ILC cases with CAD (ImageChecker {sup registered}, Hologic vertical stroke R2, Santa Clara, CA, versions 2.3, 3.1, 3.2, 5.0, 5.2) diagnosed between June 2002 and December 2004 were retrospectively reviewed. Data included: BIRADS {sup registered} breast density, whether CAD marked the cancer at diagnosis year or years prior, and lesion type. Study mammograms underwent additional CAD scans (Image Checker {sup registered} V5.3, V8.0, V8.1) to obtain a numeric value associated with each marker, low values represent increasingly suspicious features. CAD correctly marked 65% (52/80) of ILC cases, detection was found to decrease with increased breast density. Numeric values of CAD marks at sites of carcinoma showed median score of 171 (range 0 - 1121). The CAD marker may potentially be used as an additional indicator of suspicious lesion features in all breast densities and higher likelihood that an area on the mammogram requires further investigation. (orig.)

  19. Computer-aided diagnosis and artificial intelligence in clinical imaging.

    Science.gov (United States)

    Shiraishi, Junji; Li, Qiang; Appelbaum, Daniel; Doi, Kunio

    2011-11-01

    Computer-aided diagnosis (CAD) is rapidly entering the radiology mainstream. It has already become a part of the routine clinical work for the detection of breast cancer with mammograms. The computer output is used as a "second opinion" in assisting radiologists' image interpretations. The computer algorithm generally consists of several steps that may include image processing, image feature analysis, and data classification via the use of tools such as artificial neural networks (ANN). In this article, we will explore these and other current processes that have come to be referred to as "artificial intelligence." One element of CAD, temporal subtraction, has been applied for enhancing interval changes and for suppressing unchanged structures (eg, normal structures) between 2 successive radiologic images. To reduce misregistration artifacts on the temporal subtraction images, a nonlinear image warping technique for matching the previous image to the current one has been developed. Development of the temporal subtraction method originated with chest radiographs, with the method subsequently being applied to chest computed tomography (CT) and nuclear medicine bone scans. The usefulness of the temporal subtraction method for bone scans was demonstrated by an observer study in which reading times and diagnostic accuracy improved significantly. An additional prospective clinical study verified that the temporal subtraction image could be used as a "second opinion" by radiologists with negligible detrimental effects. ANN was first used in 1990 for computerized differential diagnosis of interstitial lung diseases in CAD. Since then, ANN has been widely used in CAD schemes for the detection and diagnosis of various diseases in different imaging modalities, including the differential diagnosis of lung nodules and interstitial lung diseases in chest radiography, CT, and position emission tomography/CT. It is likely that CAD will be integrated into picture archiving and

  20. An Experiment and Detection Scheme for Cavity-Based Light Cold Dark Matter Particle Searches

    Directory of Open Access Journals (Sweden)

    Masroor H. S. Bukhari

    2017-01-01

    Full Text Available A resonance detection scheme and some useful ideas for cavity-based searches of light cold dark matter particles (such as axions are presented, as an effort to aid in the on-going endeavors in this direction as well as for future experiments, especially in possibly developing a table-top experiment. The scheme is based on our idea of a resonant detector, incorporating an integrated tunnel diode (TD and GaAs HEMT/HFET (High-Electron Mobility Transistor/Heterogeneous FET transistor amplifier, weakly coupled to a cavity in a strong transverse magnetic field. The TD-amplifier combination is suggested as a sensitive and simple technique to facilitate resonance detection within the cavity while maintaining excellent noise performance, whereas our proposed Halbach magnet array could serve as a low-noise and permanent solution replacing the conventional electromagnets scheme. We present some preliminary test results which demonstrate resonance detection from simulated test signals in a small optimal axion mass range with superior signal-to-noise ratios (SNR. Our suggested design also contains an overview of a simpler on-resonance dc signal read-out scheme replacing the complicated heterodyne read-out. We believe that all these factors and our propositions could possibly improve or at least simplify the resonance detection and read-out in cavity-based DM particle detection searches (and other spectroscopy applications and reduce the complications (and associated costs, in addition to reducing the electromagnetic interference and background.

  1. Computer-aided classification of lung nodules on computed tomography images via deep learning technique

    Directory of Open Access Journals (Sweden)

    Hua KL

    2015-08-01

    Full Text Available Kai-Lung Hua,1 Che-Hao Hsu,1 Shintami Chusnul Hidayati,1 Wen-Huang Cheng,2 Yu-Jen Chen3 1Department of Computer Science and Information Engineering, National Taiwan University of Science and Technology, 2Research Center for Information Technology Innovation, Academia Sinica, 3Department of Radiation Oncology, MacKay Memorial Hospital, Taipei, Taiwan Abstract: Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain. Keywords: nodule classification, deep learning, deep belief network, convolutional neural network

  2. Automatic bone detection and soft tissue aware ultrasound-CT registration for computer-aided orthopedic surgery.

    Science.gov (United States)

    Wein, Wolfgang; Karamalis, Athanasios; Baumgartner, Adrian; Navab, Nassir

    2015-06-01

    The transfer of preoperative CT data into the tracking system coordinates within an operating room is of high interest for computer-aided orthopedic surgery. In this work, we introduce a solution for intra-operative ultrasound-CT registration of bones. We have developed methods for fully automatic real-time bone detection in ultrasound images and global automatic registration to CT. The bone detection algorithm uses a novel bone-specific feature descriptor and was thoroughly evaluated on both in-vivo and ex-vivo data. A global optimization strategy aligns the bone surface, followed by a soft tissue aware intensity-based registration to provide higher local registration accuracy. We evaluated the system on femur, tibia and fibula anatomy in a cadaver study with human legs, where magnetically tracked bone markers were implanted to yield ground truth information. An overall median system error of 3.7 mm was achieved on 11 datasets. Global and fully automatic registration of bones aquired with ultrasound to CT is feasible, with bone detection and tracking operating in real time for immediate feedback to the surgeon.

  3. Integrated computer aided design simulation and manufacture

    OpenAIRE

    Diko, Faek

    1989-01-01

    Computer Aided Design (CAD) and Computer Aided Manufacture (CAM) have been investigated and developed since twenty years as standalone systems. A large number of very powerful but independent packages have been developed for Computer Aided Design,Aanlysis and Manufacture. However, in most cases these packages have poor facility for communicating with other packages. Recently attempts have been made to develop integrated CAD/CAM systems and many software companies a...

  4. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Destounis, Stamatia [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States); University of Rochester, School of Medicine and Dentistry, Rochester, NY (United States); Hanson, Sarah; Morgan, Renee; Murphy, Philip; Somerville, Patricia; Seifert, Posy; Andolina, Valerie; Arieno, Andrea; Skolny, Melissa; Logan-Young, Wende [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States)

    2009-06-15

    A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRADS {sup registered} category 1 digital mammography examinations were randomly identified to serve as a comparative normal/control population. Data included patient age; BIRADS {sup registered} breast density; lesion type, size, and visibility; number, type, and location of CAD marks per image; CAD ability to mark lesions; needle core and surgical pathologic correlation. The CAD lesion/case sensitivity of 87% (n=39), image sensitivity of 69% (n=31) for mediolateral oblique view and 78% (n=35) for the craniocaudal view was found. The average false positive rate in 44 normal screening cases was 2.0 (range 1-8). The 2.0 figure is based on 88 reported false positive CAD marks in 44 normal screening exams: 98% (n=44) lesions proceeded to excision; initial pathology upgraded at surgical excision from in situ to invasive disease in 24% (n=9) lesions. CAD demonstrated potential to detect mammographically visible cancers in standard projections for all lesion types. (orig.)

  5. Massive-training artificial neural network (MTANN) for reduction of false positives in computer-aided detection of polyps: Suppression of rectal tubes

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Yoshida, Hiroyuki; Naeppi, Janne; Dachman, Abraham H.

    2006-01-01

    One of the limitations of the current computer-aided detection (CAD) of polyps in CT colonography (CTC) is a relatively large number of false-positive (FP) detections. Rectal tubes (RTs) are one of the typical sources of FPs because a portion of a RT, especially a portion of a bulbous tip, often exhibits a cap-like shape that closely mimics the appearance of a small polyp. Radiologists can easily recognize and dismiss RT-induced FPs; thus, they may lose their confidence in CAD as an effective tool if the CAD scheme generates such ''obvious'' FPs due to RTs consistently. In addition, RT-induced FPs may distract radiologists from less common true positives in the rectum. Therefore, removal RT-induced FPs as well as other types of FPs is desirable while maintaining a high sensitivity in the detection of polyps. We developed a three-dimensional (3D) massive-training artificial neural network (MTANN) for distinction between polyps and RTs in 3D CTC volumetric data. The 3D MTANN is a supervised volume-processing technique which is trained with input CTC volumes and the corresponding ''teaching'' volumes. The teaching volume for a polyp contains a 3D Gaussian distribution, and that for a RT contains zeros for enhancement of polyps and suppression of RTs, respectively. For distinction between polyps and nonpolyps including RTs, a 3D scoring method based on a 3D Gaussian weighting function is applied to the output of the trained 3D MTANN. Our database consisted of CTC examinations of 73 patients, scanned in both supine and prone positions (146 CTC data sets in total), with optical colonoscopy as a reference standard for the presence of polyps. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. These CTC cases were subjected to our previously reported CAD scheme that included centerline-based segmentation of the colon, shape-based detection of polyps, and reduction of FPs by use of a Bayesian neural network based on geometric and texture

  6. Automatic computer aided analysis algorithms and system for adrenal tumors on CT images.

    Science.gov (United States)

    Chai, Hanchao; Guo, Yi; Wang, Yuanyuan; Zhou, Guohui

    2017-12-04

    The adrenal tumor will disturb the secreting function of adrenocortical cells, leading to many diseases. Different kinds of adrenal tumors require different therapeutic schedules. In the practical diagnosis, it highly relies on the doctor's experience to judge the tumor type by reading the hundreds of CT images. This paper proposed an automatic computer aided analysis method for adrenal tumors detection and classification. It consisted of the automatic segmentation algorithms, the feature extraction and the classification algorithms. These algorithms were then integrated into a system and conducted on the graphic interface by using MATLAB Graphic user interface (GUI). The accuracy of the automatic computer aided segmentation and classification reached 90% on 436 CT images. The experiments proved the stability and reliability of this automatic computer aided analytic system.

  7. Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection

    International Nuclear Information System (INIS)

    Linguraru, Marius George; Panjwani, Neil; Fletcher, Joel G.; Summer, Ronald M.

    2011-01-01

    Purpose: To evaluate the performance of a computer-aided detection (CAD) system for detecting colonic polyps at noncathartic computed tomography colonography (CTC) in conjunction with an automated image-based colon cleansing algorithm. Methods: An automated colon cleansing algorithm was designed to detect and subtract tagged-stool, accounting for heterogeneity and poor tagging, to be used in conjunction with a colon CAD system. The method is locally adaptive and combines intensity, shape, and texture analysis with probabilistic optimization. CTC data from cathartic-free bowel preparation were acquired for testing and training the parameters. Patients underwent various colonic preparations with barium or Gastroview in divided doses over 48 h before scanning. No laxatives were administered and no dietary modifications were required. Cases were selected from a polyp-enriched cohort and included scans in which at least 90% of the solid stool was visually estimated to be tagged and each colonic segment was distended in either the prone or supine view. The CAD system was run comparatively with and without the stool subtraction algorithm. Results: The dataset comprised 38 CTC scans from prone and/or supine scans of 19 patients containing 44 polyps larger than 10 mm (22 unique polyps, if matched between prone and supine scans). The results are robust on fine details around folds, thin-stool linings on the colonic wall, near polyps and in large fluid/stool pools. The sensitivity of the CAD system is 70.5% per polyp at a rate of 5.75 false positives/scan without using the stool subtraction module. This detection improved significantly (p = 0.009) after automated colon cleansing on cathartic-free data to 86.4% true positive rate at 5.75 false positives/scan. Conclusions: An automated image-based colon cleansing algorithm designed to overcome the challenges of the noncathartic colon significantly improves the sensitivity of colon CAD by approximately 15%.

  8. Value of a Computer-aided Detection System Based on Chest Tomosynthesis Imaging for the Detection of Pulmonary Nodules.

    Science.gov (United States)

    Yamada, Yoshitake; Shiomi, Eisuke; Hashimoto, Masahiro; Abe, Takayuki; Matsusako, Masaki; Saida, Yukihisa; Ogawa, Kenji

    2018-04-01

    Purpose To assess the value of a computer-aided detection (CAD) system for the detection of pulmonary nodules on chest tomosynthesis images. Materials and Methods Fifty patients with and 50 without pulmonary nodules underwent both chest tomosynthesis and multidetector computed tomography (CT) on the same day. Fifteen observers (five interns and residents, five chest radiologists, and five abdominal radiologists) independently evaluated tomosynthesis images of 100 patients for the presence of pulmonary nodules in a blinded and randomized manner, first without CAD, then with the inclusion of CAD marks. Multidetector CT images served as the reference standard. Free-response receiver operating characteristic analysis was used for the statistical analysis. Results The pooled diagnostic performance of 15 observers was significantly better with CAD than without CAD (figure of merit [FOM], 0.74 vs 0.71, respectively; P = .02). The average true-positive fraction and false-positive rate per all cases with CAD were 0.56 and 0.26, respectively, whereas those without CAD were 0.47 and 0.20, respectively. Subanalysis showed that the diagnostic performance of interns and residents was significantly better with CAD than without CAD (FOM, 0.70 vs 0.62, respectively; P = .001), whereas for chest radiologists and abdominal radiologists, the FOM with CAD values were greater but not significantly: 0.80 versus 0.78 (P = .38) and 0.74 versus 0.73 (P = .65), respectively. Conclusion CAD significantly improved diagnostic performance in the detection of pulmonary nodules on chest tomosynthesis images for interns and residents, but provided minimal benefit for chest radiologists and abdominal radiologists. © RSNA, 2017 Online supplemental material is available for this article.

  9. Computer-Aided Detection of Malignant Lung Nodules on Chest Radiographs: Effect on Observers' Performance

    International Nuclear Information System (INIS)

    Lee, Kyung Hee; Goo, Jin Mo; Park, Chang Min; Lee, Hyun Ju; Jin, Kwang Nam

    2012-01-01

    To evaluate the effect of computer-aided detection (CAD) system on observer performance in the detection of malignant lung nodules on chest radiograph. Two hundred chest radiographs (100 normal and 100 abnormal with malignant solitary lung nodules) were evaluated. With CT and histological confirmation serving as a reference, the mean nodule size was 15.4 mm (range, 7-20 mm). Five chest radiologists and five radiology residents independently interpreted both the original radiographs and CAD output images using the sequential testing method. The performances of the observers for the detection of malignant nodules with and without CAD were compared using the jackknife free-response receiver operating characteristic analysis. Fifty-nine nodules were detected by the CAD system with a false positive rate of 1.9 nodules per case. The detection of malignant lung nodules significantly increased from 0.90 to 0.92 for a group of observers, excluding one first-year resident (p = 0.04). When lowering the confidence score was not allowed, the average figure of merit also increased from 0.90 to 0.91 (p = 0.04) for all observers after a CAD review. On average, the sensitivities with and without CAD were 87% and 84%, respectively; the false positive rates per case with and without CAD were 0.19 and 0.17, respectively. The number of additional malignancies detected following true positive CAD marks ranged from zero to seven for the various observers. The CAD system may help improve observer performance in detecting malignant lung nodules on chest radiographs and contribute to a decrease in missed lung cancer.

  10. Robust second-order scheme for multi-phase flow computations

    Science.gov (United States)

    Shahbazi, Khosro

    2017-06-01

    A robust high-order scheme for the multi-phase flow computations featuring jumps and discontinuities due to shock waves and phase interfaces is presented. The scheme is based on high-order weighted-essentially non-oscillatory (WENO) finite volume schemes and high-order limiters to ensure the maximum principle or positivity of the various field variables including the density, pressure, and order parameters identifying each phase. The two-phase flow model considered besides the Euler equations of gas dynamics consists of advection of two parameters of the stiffened-gas equation of states, characterizing each phase. The design of the high-order limiter is guided by the findings of Zhang and Shu (2011) [36], and is based on limiting the quadrature values of the density, pressure and order parameters reconstructed using a high-order WENO scheme. The proof of positivity-preserving and accuracy is given, and the convergence and the robustness of the scheme are illustrated using the smooth isentropic vortex problem with very small density and pressure. The effectiveness and robustness of the scheme in computing the challenging problem of shock wave interaction with a cluster of tightly packed air or helium bubbles placed in a body of liquid water is also demonstrated. The superior performance of the high-order schemes over the first-order Lax-Friedrichs scheme for computations of shock-bubble interaction is also shown. The scheme is implemented in two-dimensional space on parallel computers using message passing interface (MPI). The proposed scheme with limiter features approximately 50% higher number of inter-processor message communications compared to the corresponding scheme without limiter, but with only 10% higher total CPU time. The scheme is provably second-order accurate in regions requiring positivity enforcement and higher order in the rest of domain.

  11. Computer-Aided Qualitative Data Analysis with Word

    Directory of Open Access Journals (Sweden)

    Bruno Nideröst

    2002-05-01

    Full Text Available Despite some fragmentary references in the literature about qualitative methods, it is fairly unknown that Word can be successfully used for computer-aided Qualitative Data Analyses (QDA. Based on several Word standard operations, elementary QDA functions such as sorting data, code-and-retrieve and frequency counts can be realized. Word is particularly interesting for those users who wish to have first experiences with computer-aided analysis before investing time and money in a specialized QDA Program. The well-known standard software could also be an option for those qualitative researchers who usually work with word processing but have certain reservations towards computer-aided analysis. The following article deals with the most important requirements and options of Word for computer-aided QDA. URN: urn:nbn:de:0114-fqs0202225

  12. Computer-aided detection of small pulmonary nodules in multidetector spiral computed tomography (MSCT) in children

    International Nuclear Information System (INIS)

    Honnef, D.; Behrendt, F.F.; Hohl, C.; Mahnken, A.H.; Guenther, R.W.; Das, M.; Mertens, R.; Stanzel, S.

    2008-01-01

    Purpose: Retrospective evaluation of computer-aided detection software (CAD) for automated detection (LungCAD, Siemens Medical solutions, Forchheim, Germany) and volumetry (LungCARE) of pulmonary nodules in dose-reduced pediatric MDCT. Materials and Methods: 30 scans of 24 children (10.4±5.9 years, 13 girls, 11 boys, 39.7±29.3 kg body weight) were performed on a 16-MDCT for tumor staging (n=18), inflammation (n=9), other indications (n=3). Tube voltage 120 kVp and effective mAs were adapted to body weight. Slice thickness 2 mm, increment 1 mm. A pediatric radiologist (U1), a CAD expert (U2) and an inexperienced radiologist (U3) independently analyzed the lung window images without and with the CAD as a second reader. In a consensus decision U1 and U2 were the reference standard. Results: Five examinations had to be excluded from the study due to other underlying lung disease. A total of 24 pulmonary nodules were found in all data sets with a minimal diameter of 0.35 mm to 3.81 mm (mean 1.7±0.85 mm). The sensitivities were as follows: U1 95.8% and 100% with CAD; U2 91.7% U3 66.7%. U2 and U3 did not detect further nodules with CAD. The sensitivity of CAD alone was 41.7% with 0.32 false-positive findings per examination. Interobserver agreement between U1/U2 regarding nodule detection with CAD was good (k=0.6500) and without CAD very good (k=0.8727). For the rest (U1/U3; U2/U3 with and without CAD), it was weak (k=0.0667-0.1884). Depending on the measured value (axial measurement, volume), there is a significant correlation (p=0.0026-0.0432) between nodule size and CAD detection. Undetected pulmonary nodules (mean 1.35 mm; range 0.35-2.61 mm) were smaller than the detected ones (mean 2.19 mm; range 1.35-3.81 mm). No significant correlation was found between CAD findings and patient age (p=0.9263) and body weight (p=0.9271) as well as nodule location (subpleural, intraparenchymal; p=1.0) and noise/SNR. (orig.)

  13. Computer-aided diagnostic system for detection of Hashimoto thyroiditis on ultrasound images from a Polish population.

    Science.gov (United States)

    Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S

    2014-02-01

    Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.

  14. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.

    Science.gov (United States)

    Huang, Qinghua; Zhang, Fan; Li, Xuelong

    2018-01-01

    The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  15. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    Directory of Open Access Journals (Sweden)

    Qinghua Huang

    2018-01-01

    Full Text Available The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  16. Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT)

    Science.gov (United States)

    Consortium and Partners | Transportation Research | NREL Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Consortium and Partners Computer-Aided Engineering for Electric -Drive Vehicle Batteries (CAEBAT) Consortium and Partners The Computer-Aided Engineering for Electric

  17. Present state of computer-aided diagnosis (CAD) development

    International Nuclear Information System (INIS)

    Fujita, Hiroshi

    2007-01-01

    Topics of computer-aided detection (CAD) are reviewed. Commercially available, Food and Drug Administration (FDA)-approved CAD systems are for fields of breast cancer (mammography), chest (flat X-ray and CT imaging) and colon (polyp detection). In Japan, only mammography CAD is approved. Efficacy of CAD is controversial, for which reliable database is important, and its construction is under development in various medical fields. Digitalized image is now popularized, which conceivably leads to improve the cost-effectiveness of diagnosis with CAD. For incentive, approval for health insurance would be the case as seen in the increased CAD sale by R2 Technology Co., and MHLW actually assists facilities to introduce the reading-aid system of mammography by sharing a half of its cost. There are 2 big projects for CAD study supported by MECSST, which the author concerns. One is the development of diagnostic aid for the multi-dimensional medical images where the multi-organ, multi-disease CAD system is considered. The other involves the CAD in brain MRI, in breast US and in eyeground picture. It is not in so far future for patients and doctors to fully enjoy the benefit of CAD. (R.T.)

  18. Computer-aided detection system for lung cancer in computed tomography scans: Review and future prospects

    Science.gov (United States)

    2014-01-01

    Introduction The goal of this paper is to present a critical review of major Computer-Aided Detection systems (CADe) for lung cancer in order to identify challenges for future research. CADe systems must meet the following requirements: improve the performance of radiologists providing high sensitivity in the diagnosis, a low number of false positives (FP), have high processing speed, present high level of automation, low cost (of implementation, training, support and maintenance), the ability to detect different types and shapes of nodules, and software security assurance. Methods The relevant literature related to “CADe for lung cancer” was obtained from PubMed, IEEEXplore and Science Direct database. Articles published from 2009 to 2013, and some articles previously published, were used. A systemic analysis was made on these articles and the results were summarized. Discussion Based on literature search, it was observed that many if not all systems described in this survey have the potential to be important in clinical practice. However, no significant improvement was observed in sensitivity, number of false positives, level of automation and ability to detect different types and shapes of nodules in the studied period. Challenges were presented for future research. Conclusions Further research is needed to improve existing systems and propose new solutions. For this, we believe that collaborative efforts through the creation of open source software communities are necessary to develop a CADe system with all the requirements mentioned and with a short development cycle. In addition, future CADe systems should improve the level of automation, through integration with picture archiving and communication systems (PACS) and the electronic record of the patient, decrease the number of false positives, measure the evolution of tumors, evaluate the evolution of the oncological treatment, and its possible prognosis. PMID:24713067

  19. Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism.

    Science.gov (United States)

    Buhmann, Sonja; Herzog, Peter; Liang, Jin; Wolf, Mathias; Salganicoff, Marcos; Kirchhoff, Chlodwig; Reiser, Maximilian; Becker, Christoph H

    2007-06-01

    To evaluate the performance of a prototype computer-aided diagnosis (CAD) tool using artificial intelligence techniques for the detection of pulmonary embolism (PE) and the possible benefit for general radiologists. Forty multidetector row computed tomography datasets (16/64- channel scanner) using 100 kVp, 100 mAs effective/slice, and 1-mm axial reformats in a low-frequency reconstruction kernel were evaluated. A total of 80 mL iodinated contrast material was injected at a flow rate of 5 mL/seconds. Primarily, six general radiologists marked any PE using a commercially available lung evaluation software with simultaneous, automatic processing by CAD in the background. An expert panel consisting of two chest radiologists analyzed all PE marks from the readers and CAD, also searching for additional finding primarily missed by both, forming the ground truth. The ground truth consisted of 212 emboli. Of these, 65 (31%) were centrally and 147 (69%) were peripherally located. The readers detected 157/212 emboli (74%) leading to a sensitivity of 97% (63/65) for central and 70% (103/147) for peripheral emboli with 9 false-positive findings. CAD detected 168/212 emboli (79%), reaching a sensitivity of 74% for central (48/65) and 82%(120/147) for peripheral emboli. A total of 154 CAD candidates were considered as false positives, yielding an average of 3.85 false positives/case. The CAD software showed a sensitivity comparable to that of the general radiologists, but with more false positives. CAD detection of findings incremental to the radiologists suggests benefit when used as a second reader. Future versions of CAD have the potential to further increase clinical benefit by improving sensitivity and reducing false marks.

  20. Application of computer aided tolerance analysis in product design

    International Nuclear Information System (INIS)

    Du Hua

    2009-01-01

    This paper introduces the shortage of the traditional tolerance design method and the strong point of the computer aided tolerancing (CAT) method,compares the shortage and the strong point among the three tolerance analysis methods, which are Worst Case Analysis, Statistical Analysis and Monte-Carlo Simulation Analysis, and offers the basic courses and correlative details for CAT. As the study objects, the reactor pressure vessel, the core barrel, the hold-down barrel and the support plate are used to upbuild the tolerance simulation model, based on their 3D design models. Then the tolerance simulation analysis has been conducted and the scheme of the tolerance distribution is optimized based on the analysis results. (authors)

  1. Feasibility Study of a Generalized Framework for Developing Computer-Aided Detection Systems-a New Paradigm.

    Science.gov (United States)

    Nemoto, Mitsutaka; Hayashi, Naoto; Hanaoka, Shouhei; Nomura, Yukihiro; Miki, Soichiro; Yoshikawa, Takeharu

    2017-10-01

    We propose a generalized framework for developing computer-aided detection (CADe) systems whose characteristics depend only on those of the training dataset. The purpose of this study is to show the feasibility of the framework. Two different CADe systems were experimentally developed by a prototype of the framework, but with different training datasets. The CADe systems include four components; preprocessing, candidate area extraction, candidate detection, and candidate classification. Four pretrained algorithms with dedicated optimization/setting methods corresponding to the respective components were prepared in advance. The pretrained algorithms were sequentially trained in the order of processing of the components. In this study, two different datasets, brain MRA with cerebral aneurysms and chest CT with lung nodules, were collected to develop two different types of CADe systems in the framework. The performances of the developed CADe systems were evaluated by threefold cross-validation. The CADe systems for detecting cerebral aneurysms in brain MRAs and for detecting lung nodules in chest CTs were successfully developed using the respective datasets. The framework was shown to be feasible by the successful development of the two different types of CADe systems. The feasibility of this framework shows promise for a new paradigm in the development of CADe systems: development of CADe systems without any lesion specific algorithm designing.

  2. Effect of Computer-Aided Detection on Mammographic Performance: Experimental Study on Readers with Different Levels of Experience

    International Nuclear Information System (INIS)

    Hukkinen, K.; Vehmas, T.; Pamilo, M.; Kivisaari, L.

    2006-01-01

    Purpose: To evaluate the effect of computer-aided detection (CAD) on the reader's performance. Material and Methods: Four screening radiologists, two novice radiologists, and two residents with no prior experience in CAD read films of 200 women without and with CAD. The films, including 16 screen-detected cancers and 35 cancers 'missed' on prior screening, were divided into two rollers: A (free time schedule) and B (prompted time schedule). Reading times were noted. Individual readings without and with CAD were compared, sensitivities and specificities were calculated. Results: The sensitivity of CAD was 70.6% and specificity 15.8%. In 408 cancer readings, the screeners found 10 and other readers 7 new cancers with the aid of CAD. The screeners changed their opinion four times and others six times from true positive to false negative when CAD was negative. CAD output produced 12 versus 13 new false-positive findings respectively after 2352 readings. CAD did not significantly affect the reader's sensitivities/specificities regardless of the time limit (P = not significant). The use of CAD increased mean time for roller reading from 56 to 63 min (P = 0.053). Conclusion: Screening radiologists benefited slightly more from CAD than other readers did, but no statistical significant difference was found in personal readings without and with CAD

  3. Privacy preserving cloud computation using Domingo-Ferrer scheme

    Directory of Open Access Journals (Sweden)

    Abdulatif Alabdulatif

    2016-01-01

    Full Text Available Homomorphic encryption system (HES schemes are anticipated to play a significant role in cloud-based applications. Moving to cloud-based storage and analytic services securely are two of the most important advantages of HES. Several HES schemes have been recently proposed. However, the majority of them either have limited capabilities or are impractical in real-world applications. Various HES schemes provide the ability to perform computations for statistical analysis (e.g. average, mean and variance on encrypted data. Domingo-Ferrer is one scheme that has privacy homomorphism properties to perform the basic mathematical operations (addition, subtraction and multiplication in a convenient and secure way. However, it works only in the positive numbers’ range which is considered as a limitation because several applications require both positive and negative ranges in which to work, especially those that have to implement analytical services in cloud computing. In this paper, we extend Domingo-Ferrer’s scheme to be able to perform arithmetic operations for both positive and negative numbers. We also propose using a lightweight data aggregation function to compute both maximum and minimum values of the aggregated data that works for both positive and negative numbers.

  4. Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) |

    Science.gov (United States)

    Transportation Research | NREL Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Graphic of a 24-cell (bottom). Images: Courtesy of EC Power NREL's work on the U.S. Department of Energy Computer-Aided

  5. A Replica Detection Scheme Based on the Deviation in Distance Traveled Sliding Window for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Alekha Kumar Mishra

    2017-01-01

    Full Text Available Node replication attack possesses a high level of threat in wireless sensor networks (WSNs and it is severe when the sensors are mobile. A limited number of replica detection schemes in mobile WSNs (MWSNs have been reported till date, where most of them are centralized in nature. The centralized detection schemes use time-location claims and the base station (BS is solely responsible for detecting replica. Therefore, these schemes are prone to single point of failure. There is also additional communication overhead associated with sending time-location claims to the BS. A distributed detection mechanism is always a preferred solution to the above kind of problems due to significantly lower communication overhead than their counterparts. In this paper, we propose a distributed replica detection scheme for MWSNs. In this scheme, the deviation in the distance traveled by a node and its replica is recorded by the observer nodes. Every node is an observer node for some nodes in the network. Observers are responsible for maintaining a sliding window of recent time-distance broadcast of the nodes. A replica is detected by an observer based on the degree of violation computed from the deviations recorded using the time-distance sliding window. The analysis and simulation results show that the proposed scheme is able to achieve higher detection probability compared to distributed replica detection schemes such as Efficient Distributed Detection (EDD and Multi-Time-Location Storage and Diffusion (MTLSD.

  6. Study on computer-aided diagnosis of hepatic MR imaging and mammography

    International Nuclear Information System (INIS)

    Zhang Xuejun

    2005-01-01

    It is well known that the liver is an organ easily attacked by diseases. The purpose of this study is to develop a computer-aided diagnosis (CAD) scheme for helping radiologists to differentiate hepatic diseases more efficiently. Our software named LIVERANN integrated the magnetic resonance (MR) imaging findings with different pulse sequences to classify the five categories of hepatic diseases by using the artificial neural network (ANN) method. The intensity and homogeneity within the region of interest (ROI) delineated by a radiologist were automatically calculated to obtain numerical data by the program for input signals to the ANN. Outputs were the five pathological categories of hepatic diseases (hepatic cyst, hepatocellular carcinoma, dysplasia in cirrhosis, cavernous hemangioma, and metastasis). The experiment demonstrated a testing accuracy of 93% from 80 patients. In order to differentiate the cirrhosis from normal liver, the volume ratio of left to whole (LTW) was proposed to quantify the degree of cirrhosis by three-dimensional (3D) volume analysis. The liver region was firstly extracted from computed tomography (CT) or MR slices based on edge detection algorithms, and then separated into left lobe and right lobe by the hepatic umbilical fissure. The volume ratio of these two parts showed that the LTW ratio in the liver was significantly improved in the differentiation performance, with (25.6%±4.3%) in cirrhosis versus the normal liver (16.4%±5.4%). In addition, the application of the ANN method for detecting clustered microcalcifications in masses on mammograms was described here as well. A new structural ANN, so-called a shift-invariant artificial neural network (SIANN), was integrated with our triple-ring filter (TRF) method in our CAD system. As the result, the sensitivity of detecting clusters was improved from 90% by our previous TRF method to 95% by using both SIANN and TRF

  7. A computer-aided detection (CAD) system with a 3D algorithm for small acute intracranial hemorrhage

    Science.gov (United States)

    Wang, Ximing; Fernandez, James; Deshpande, Ruchi; Lee, Joon K.; Chan, Tao; Liu, Brent

    2012-02-01

    Acute Intracranial hemorrhage (AIH) requires urgent diagnosis in the emergency setting to mitigate eventual sequelae. However, experienced radiologists may not always be available to make a timely diagnosis. This is especially true for small AIH, defined as lesion smaller than 10 mm in size. A computer-aided detection (CAD) system for the detection of small AIH would facilitate timely diagnosis. A previously developed 2D algorithm shows high false positive rates in the evaluation based on LAC/USC cases, due to the limitation of setting up correct coordinate system for the knowledge-based classification system. To achieve a higher sensitivity and specificity, a new 3D algorithm is developed. The algorithm utilizes a top-hat transformation and dynamic threshold map to detect small AIH lesions. Several key structures of brain are detected and are used to set up a 3D anatomical coordinate system. A rule-based classification of the lesion detected is applied based on the anatomical coordinate system. For convenient evaluation in clinical environment, the CAD module is integrated with a stand-alone system. The CAD is evaluated by small AIH cases and matched normal collected in LAC/USC. The result of 3D CAD and the previous 2D CAD has been compared.

  8. A Modified Computational Scheme for the Stochastic Perturbation Finite Element Method

    Directory of Open Access Journals (Sweden)

    Feng Wu

    Full Text Available Abstract A modified computational scheme of the stochastic perturbation finite element method (SPFEM is developed for structures with low-level uncertainties. The proposed scheme can provide second-order estimates of the mean and variance without differentiating the system matrices with respect to the random variables. When the proposed scheme is used, it involves finite analyses of deterministic systems. In the case of one random variable with a symmetric probability density function, the proposed computational scheme can even provide a result with fifth-order accuracy. Compared with the traditional computational scheme of SPFEM, the proposed scheme is more convenient for numerical implementation. Four numerical examples demonstrate that the proposed scheme can be used in linear or nonlinear structures with correlated or uncorrelated random variables.

  9. Computer aided design

    International Nuclear Information System (INIS)

    Barache, J.M.; Beltranda, G.; Blanc, P.

    1987-01-01

    In order to ensure that the data transmitted to the managment system is of the required quality and consistent with the general control command protocols, computer aided design (CAD) was employed for level N4. One describes the use of CAD for the control system of N4 [fr

  10. [Clinical skills and outcomes of chair-side computer aided design and computer aided manufacture system].

    Science.gov (United States)

    Yu, Q

    2018-04-09

    Computer aided design and computer aided manufacture (CAD/CAM) technology is a kind of oral digital system which is applied to clinical diagnosis and treatment. It overturns the traditional pattern, and provides a solution to restore defect tooth quickly and efficiently. In this paper we mainly discuss the clinical skills of chair-side CAD/CAM system, including tooth preparation, digital impression, the three-dimensional design of prosthesis, numerical control machining, clinical bonding and so on, and review the outcomes of several common kinds of materials at the same time.

  11. An esthetics rehabilitation with computer-aided design/ computer-aided manufacturing technology.

    Science.gov (United States)

    Mazaro, Josá Vitor Quinelli; de Mello, Caroline Cantieri; Zavanelli, Adriana Cristina; Santiago, Joel Ferreira; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza

    2014-07-01

    This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.

  12. Computer aided detection of surgical retained foreign object for prevention

    International Nuclear Information System (INIS)

    Hadjiiski, Lubomir; Marentis, Theodore C.; Rondon, Lucas; Chan, Heang-Ping; Chaudhury, Amrita R.; Chronis, Nikolaos

    2015-01-01

    Purpose: Surgical retained foreign objects (RFOs) have significant morbidity and mortality. They are associated with approximately $1.5 × 10 9 annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. The authors address the RFO problem with two complementary technologies: a three-dimensional (3D) gossypiboma micro tag, the μTag that improves the visibility of RFOs on radiographs, and a computer aided detection (CAD) system that detects the μTag. It is desirable for the CAD system to operate in a high specificity mode in the operating room (OR) and function as a first reader for the surgeon. This allows for fast point of care results and seamless workflow integration. The CAD system can also operate in a high sensitivity mode as a second reader for the radiologist to ensure the highest possible detection accuracy. Methods: The 3D geometry of the μTag produces a similar two dimensional (2D) depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. The authors created a data set of 1800 cadaver images with the 3D μTag and other common man-made surgical objects positioned randomly. A total of 1061 cadaver images contained a single μTag and the remaining 739 were without μTag. A radiologist marked the location of the μTag using an in-house developed graphical user interface. The data set was partitioned into three independent subsets: a training set, a validation set, and a test set, consisting of 540, 560, and 700 images, respectively. A CAD system with modules that included preprocessing μTag enhancement, labeling, segmentation, feature analysis, classification, and detection was developed. The CAD system was developed using the training and the validation sets. Results: On the training set, the CAD achieved 81.5% sensitivity with 0.014 false positives (FPs) per image in a high specificity mode for the surgeons in the OR and 96

  13. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    International Nuclear Information System (INIS)

    Einarsdóttir, Hildur; Larsen, Rasmus; Ersbøll, Bjarne Kjær; Yaroshenko, Andre; Velroyen, Astrid; Bech, Martin; Pfeiffer, Franz; Hellbach, Katharina; Auweter, Sigrid; Meinel, Felix G; Reiser, Maximilian; Yildirim, Önder; Eickelberg, Oliver

    2015-01-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually annotated to build an experimental dataset. System performance was assessed by: (i) determining the quality of the segmentations; (ii) validating emphysema and fibrosis recognition by a linear support vector machine using leave-one-out cross-validation. In terms of segmentation quality, we obtained an overlap percentage (Ω) 92.63  ±  3.65%, Dice Similarity Coefficient (DSC) 89.74  ±  8.84% and Jaccard Similarity Coefficient 82.39  ±  12.62%. For classification, the accuracy, sensitivity and specificity of diseased lung recognition was 100%. Classification between emphysema and fibrosis resulted in an accuracy of 93%, whilst the sensitivity was 94% and specificity 88%. In addition to the automatic classification of lungs, deviation maps created by the CAD scheme provide a visual aid for medical experts to further assess the severity of pulmonary disease in the lung, and highlights regions affected. (paper)

  14. Computer-aided engineering in High Energy Physics

    International Nuclear Information System (INIS)

    Bachy, G.; Hauviller, C.; Messerli, R.; Mottier, M.

    1988-01-01

    Computing, standard tool for a long time in the High Energy Physics community, is being slowly introduced at CERN in the mechanical engineering field. The first major application was structural analysis followed by Computer-Aided Design (CAD). Development work is now progressing towards Computer-Aided Engineering around a powerful data base. This paper gives examples of the power of this approach applied to engineering for accelerators and detectors

  15. Computer-aided detection (CAD) in mammography: Does it help the junior or the senior radiologist?

    International Nuclear Information System (INIS)

    Balleyguier, Corinne; Kinkel, Karen; Fermanian, Jacques; Malan, Sebastien; Djen, Germaine; Taourel, Patrice; Helenon, Olivier

    2005-01-01

    Objectives: To evaluate the impact of a computer-aided detection (CAD) system on the ability of a junior and senior radiologist to detect breast cancers on mammograms, and to determine the potential of CAD as a teaching tool in mammography. Methods: Hundred biopsy-proven cancers and 100 normal mammograms were randomly analyzed by a CAD system. The sensitivity (Se) and specificity (Sp) of the CAD system were calculated. In the second phase, to simulate daily practice, 110 mammograms (97 normal or with benign lesions, and 13 cancers) were examined independently by a junior and a senior radiologist, with and without CAD. Interpretations were standardized according to BI-RADS classification. Sensitivity, Specificity, positive and negative predictive values (PPV, NPV) were calculated for each session. Results: For the senior radiologist, Se slightly improved from 76.9 to 84.6% after CAD analysis (NS) (one case of clustered microcalcifications case overlooked by the senior radiologist was detected by CAD). Sp, PPV and PNV did not change significantly. For the junior radiologist, Se improved from 61.9 to 84.6% (significant change). Three cancers overlooked by the junior radiologist were detected by CAD. Sp was unchanged. Conclusion: CAD mammography proved more useful for the junior than for the senior radiologist, improving sensitivity. The CAD system may represent a useful educational tool for mammography

  16. Secret-Key-Aided Scheme for Securing Untrusted DF Relaying Networks

    KAUST Repository

    Shafie, Ahmed El

    2017-06-12

    This paper proposes a new scheme to secure the transmissions in an untrusted decode-and-forward (DF) relaying network. A legitimate source node, Alice, sends her data to a legitimate destination node, Bob, with the aid of an untrusted DF relay node, Charlie. To secure the transmissions from Charlie during relaying time slots, each data codeword is secured using a secret-key codeword that has been previously shared between Alice and Bob during the perfectly secured time slots (i.e., when the channel secrecy rate is positive). The secret-key bits exchanged between Alice and Bob are stored in a finite-length buffer and are used to secure data transmission whenever needed. We model the secret-key buffer as a queueing system and analyze its Markov chain. Our numerical results show the gains of our proposed scheme relative to benchmarks. Moreover, the proposed scheme achieves an upper bound on the secure throughput.

  17. Secret-Key-Aided Scheme for Securing Untrusted DF Relaying Networks

    KAUST Repository

    Shafie, Ahmed El; Salem, Ahmed Sultan; Mabrouk, Asma; Tourki, Kamel; Al-Dhahir, Naofal

    2017-01-01

    This paper proposes a new scheme to secure the transmissions in an untrusted decode-and-forward (DF) relaying network. A legitimate source node, Alice, sends her data to a legitimate destination node, Bob, with the aid of an untrusted DF relay node, Charlie. To secure the transmissions from Charlie during relaying time slots, each data codeword is secured using a secret-key codeword that has been previously shared between Alice and Bob during the perfectly secured time slots (i.e., when the channel secrecy rate is positive). The secret-key bits exchanged between Alice and Bob are stored in a finite-length buffer and are used to secure data transmission whenever needed. We model the secret-key buffer as a queueing system and analyze its Markov chain. Our numerical results show the gains of our proposed scheme relative to benchmarks. Moreover, the proposed scheme achieves an upper bound on the secure throughput.

  18. The effects of HIV/AIDS on medical schemes in South Africa | Da ...

    African Journals Online (AJOL)

    ... not necessarily representative of the medical-scheme population. The intention is therefore to develop a methodology for producing indicative results to inform management decisions. The opportunity to lower costs related to HIV/AIDS through proactive risk management is investigated. South African Actuarial Journal Vol.

  19. Computer-aided detection of pulmonary nodules: a comparative study using the public LIDC/IDRI database

    International Nuclear Information System (INIS)

    Jacobs, Colin; Prokop, Mathias; Rikxoort, Eva M. van; Ginneken, Bram van; Murphy, Keelin; Schaefer-Prokop, Cornelia M.

    2016-01-01

    To benchmark the performance of state-of-the-art computer-aided detection (CAD) of pulmonary nodules using the largest publicly available annotated CT database (LIDC/IDRI), and to show that CAD finds lesions not identified by the LIDC's four-fold double reading process. The LIDC/IDRI database contains 888 thoracic CT scans with a section thickness of 2.5 mm or lower. We report performance of two commercial and one academic CAD system. The influence of presence of contrast, section thickness, and reconstruction kernel on CAD performance was assessed. Four radiologists independently analyzed the false positive CAD marks of the best CAD system. The updated commercial CAD system showed the best performance with a sensitivity of 82 % at an average of 3.1 false positive detections per scan. Forty-five false positive CAD marks were scored as nodules by all four radiologists in our study. On the largest publicly available reference database for lung nodule detection in chest CT, the updated commercial CAD system locates the vast majority of pulmonary nodules at a low false positive rate. Potential for CAD is substantiated by the fact that it identifies pulmonary nodules that were not marked during the extensive four-fold LIDC annotation process. (orig.)

  20. Computer-aided cleanup

    International Nuclear Information System (INIS)

    Williams, J.; Jones, B.

    1994-01-01

    In late 1992, the remedial investigation of operable unit 2 at the Department of Energy (DOE) Superfund site in Fernald, Ohio was in trouble. Despite years of effort--including an EPA-approved field-investigation work plan, 123 soil borings, 51 ground-water-monitoring wells, analysis of more than 650 soil and ground-water samples, and preparation of a draft remedial-investigation (RI) report--it was not possible to conclude if contaminated material in the unit was related to ground-water contamination previously detected beneath and beyond the site boundary. Compounding the problem, the schedule for the RI, feasibility study and record of decision for operable unit 2 was governed by a DOE-EPA consent agreement stipulating penalties of up to $10,000 per week for not meeting scheduled milestones--and time was running out. An advanced three-dimensional computer model confirmed that radioactive wastes dumped at the Fernald, Ohio Superfund site had contaminated ground water, after years of previous testing has been inconclusive. The system is now being used to aid feasibility and design work on the more-than-$1 billion remediation project

  1. Local pulmonary structure classification for computer-aided nodule detection

    Science.gov (United States)

    Bahlmann, Claus; Li, Xianlin; Okada, Kazunori

    2006-03-01

    We propose a new method of classifying the local structure types, such as nodules, vessels, and junctions, in thoracic CT scans. This classification is important in the context of computer aided detection (CAD) of lung nodules. The proposed method can be used as a post-process component of any lung CAD system. In such a scenario, the classification results provide an effective means of removing false positives caused by vessels and junctions thus improving overall performance. As main advantage, the proposed solution transforms the complex problem of classifying various 3D topological structures into much simpler 2D data clustering problem, to which more generic and flexible solutions are available in literature, and which is better suited for visualization. Given a nodule candidate, first, our solution robustly fits an anisotropic Gaussian to the data. The resulting Gaussian center and spread parameters are used to affine-normalize the data domain so as to warp the fitted anisotropic ellipsoid into a fixed-size isotropic sphere. We propose an automatic method to extract a 3D spherical manifold, containing the appropriate bounding surface of the target structure. Scale selection is performed by a data driven entropy minimization approach. The manifold is analyzed for high intensity clusters, corresponding to protruding structures. Techniques involve EMclustering with automatic mode number estimation, directional statistics, and hierarchical clustering with a modified Bhattacharyya distance. The estimated number of high intensity clusters explicitly determines the type of pulmonary structures: nodule (0), attached nodule (1), vessel (2), junction (>3). We show accurate classification results for selected examples in thoracic CT scans. This local procedure is more flexible and efficient than current state of the art and will help to improve the accuracy of general lung CAD systems.

  2. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K H; Weber, M; Weiss, M [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1999-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  3. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K.H.; Weber, M.; Weiss, M. [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1998-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  4. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review.

    Science.gov (United States)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

  5. Computer-aided diagnosis of leukoencephalopathy in children treated for acute lymphoblastic leukemia

    Science.gov (United States)

    Glass, John O.; Li, Chin-Shang; Helton, Kathleen J.; Reddick, Wilburn E.

    2005-04-01

    The purpose of this study was to use objective quantitative MR imaging methods to develop a computer-aided diagnosis tool to differentiate white matter (WM) hyperintensities as either leukoencephalopathy (LE) or normal maturational processes in children treated for acute lymphoblastic leukemia with intravenous high dose methotrexate. A combined imaging set consisting of T1, T2, PD, and FLAIR MR images and WM, gray matter, and cerebrospinal fluid a priori maps from a spatially normalized atlas were analyzed with a neural network segmentation based on a Kohonen Self-Organizing Map. Segmented regions were manually classified to identify the most hyperintense WM region and the normal appearing genu region. Signal intensity differences normalized to the genu within each examination were generated for two time points in 203 children. An unsupervised hierarchical clustering algorithm with the agglomeration method of McQuitty was used to divide data from the first examination into normal appearing or LE groups. A C-support vector machine (C-SVM) was then trained on the first examination data and used to classify the data from the second examination. The overall accuracy of the computer-aided detection tool was 83.5% (299/358) with sensitivity to normal WM of 86.9% (199/229) and specificity to LE of 77.5% (100/129) when compared to the readings of two expert observers. These results suggest that subtle therapy-induced leukoencephalopathy can be objectively and reproducibly detected in children treated for cancer using this computer-aided detection approach based on relative differences in quantitative signal intensity measures normalized within each examination.

  6. Image processing algorithm of computer-aided diagnosis in lung cancer screening by CT

    International Nuclear Information System (INIS)

    Yamamoto, Shinji

    2004-01-01

    In this paper, an image processing algorithm for computer-aided diagnosis of lung cancer by X-ray CT is described, which has been developed by my research group for these 10 years or so. CT lung images gathered at the mass screening stage are almost all normal, and lung cancer nodules will be found as the rate of less than 10%. To pick up such a very rare nodules with the high accuracy, a very sensitive detection algorithm is requested which is detectable local and very slight variation of the image. On the contrary, such a sensitive detection algorithm introduces a bad effect that a lot of normal shadows will be detected as abnormal shadows. In this paper I describe how to compromise this complicated subject and realize a practical computer-aided diagnosis tool by the image processing algorithm developed by my research group. Especially, I will mainly focus my description to the principle and characteristics of the Quoit filter which is newly developed as a high sensitive filter by my group. (author)

  7. Scheme for Quantum Computing Immune to Decoherence

    Science.gov (United States)

    Williams, Colin; Vatan, Farrokh

    2008-01-01

    A constructive scheme has been devised to enable mapping of any quantum computation into a spintronic circuit in which the computation is encoded in a basis that is, in principle, immune to quantum decoherence. The scheme is implemented by an algorithm that utilizes multiple physical spins to encode each logical bit in such a way that collective errors affecting all the physical spins do not disturb the logical bit. The scheme is expected to be of use to experimenters working on spintronic implementations of quantum logic. Spintronic computing devices use quantum-mechanical spins (typically, electron spins) to encode logical bits. Bits thus encoded (denoted qubits) are potentially susceptible to errors caused by noise and decoherence. The traditional model of quantum computation is based partly on the assumption that each qubit is implemented by use of a single two-state quantum system, such as an electron or other spin-1.2 particle. It can be surprisingly difficult to achieve certain gate operations . most notably, those of arbitrary 1-qubit gates . in spintronic hardware according to this model. However, ironically, certain 2-qubit interactions (in particular, spin-spin exchange interactions) can be achieved relatively easily in spintronic hardware. Therefore, it would be fortunate if it were possible to implement any 1-qubit gate by use of a spin-spin exchange interaction. While such a direct representation is not possible, it is possible to achieve an arbitrary 1-qubit gate indirectly by means of a sequence of four spin-spin exchange interactions, which could be implemented by use of four exchange gates. Accordingly, the present scheme provides for mapping any 1-qubit gate in the logical basis into an equivalent sequence of at most four spin-spin exchange interactions in the physical (encoded) basis. The complexity of the mathematical derivation of the scheme from basic quantum principles precludes a description within this article; it must suffice to report

  8. An automated tuberculosis screening strategy combining X-ray-based computer-aided detection and clinical information

    Science.gov (United States)

    Melendez, Jaime; Sánchez, Clara I.; Philipsen, Rick H. H. M.; Maduskar, Pragnya; Dawson, Rodney; Theron, Grant; Dheda, Keertan; van Ginneken, Bram

    2016-04-01

    Lack of human resources and radiological interpretation expertise impair tuberculosis (TB) screening programmes in TB-endemic countries. Computer-aided detection (CAD) constitutes a viable alternative for chest radiograph (CXR) reading. However, no automated techniques that exploit the additional clinical information typically available during screening exist. To address this issue and optimally exploit this information, a machine learning-based combination framework is introduced. We have evaluated this framework on a database containing 392 patient records from suspected TB subjects prospectively recruited in Cape Town, South Africa. Each record comprised a CAD score, automatically computed from a CXR, and 12 clinical features. Comparisons with strategies relying on either CAD scores or clinical information alone were performed. Our results indicate that the combination framework outperforms the individual strategies in terms of the area under the receiving operating characteristic curve (0.84 versus 0.78 and 0.72), specificity at 95% sensitivity (49% versus 24% and 31%) and negative predictive value (98% versus 95% and 96%). Thus, it is believed that combining CAD and clinical information to estimate the risk of active disease is a promising tool for TB screening.

  9. Obfuscated RSUs Vector Based Signature Scheme for Detecting Conspiracy Sybil Attack in VANETs

    Directory of Open Access Journals (Sweden)

    Xia Feng

    2017-01-01

    Full Text Available Given the popularity of vehicular Ad hoc networks (VANETs in traffic management, a new challenging issue comes into traffic safety, that is, security of the networks, especially when the adversary breaks defence. Sybil attack, for example, is a potential security threat through forging several identities to carry out attacks in VANETs. At this point, the paper proposed a solution named DMON that is a Sybil attack detection method with obfuscated neighbor relationship of Road Side Units (RSUs. DMON presents a ring signature based identification scheme and replaces vehicles’ identities with their trajectory for the purpose of anonymity. Furthermore, the neighbor relationship of RSUs is obfuscated to achieve privacy preserving of locations. The proposed scheme has been formally proved in the views of security and performance. Simulation has also been implemented to validate the scheme, in which the findings reveal the lower computational overhead and higher detection rate comparing with other related solutions.

  10. Potential clinical impact of advanced imaging and computer-aided diagnosis in chest radiology: importance of radiologist's role and successful observer study.

    Science.gov (United States)

    Li, Feng

    2015-07-01

    This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.

  11. Computer-aided diagnosis and volumetry of pulmonary nodules: current concepts and future perspectives

    International Nuclear Information System (INIS)

    Marten, K.; Rummeny, E.J.; Engelke, C.

    2005-01-01

    For computer-aided detection (CAD) and volumetry of small pulmonary nodules, a number of algorithms have been developed for multislice CT data sets in recent years, with the goal of improving the diagnostic work-up and the follow-up of findings. Recent data show that the detection of small lesions may improve with CAD, suggesting that especially experienced readers may benefit from using CAD systems. This has lead to the recommendation of CAD as a replacement of the second reader in clinical practice. Furthermore, computer-aided volumetry of pulmonary nodules allows a precise determination of nodular growth rates as a prerequisite for a better classification of nodules as benign or malignant. In this article, we review recent developments of CAD and volumetry tools for pulmonary nodules, and address open questions regarding the use of these software tools in clinical routine. (orig.)

  12. New Paradigms for Computer Aids to Invention.

    Science.gov (United States)

    Langston, M. Diane

    Many people are interested in computer aids to rhetorical invention and want to know how to evaluate an invention aid, what the criteria are for a good one, and how to assess the trade-offs involved in buying one product or another. The frame of reference for this evaluation is an "old paradigm," which treats the computer as if it were…

  13. Computer-aided detection of breast masses: Four-view strategy for screening mammography

    International Nuclear Information System (INIS)

    Wei Jun; Chan Heangping; Zhou Chuan; Wu Yita; Sahiner, Berkman; Hadjiiski, Lubomir M.; Roubidoux, Marilyn A.; Helvie, Mark A.

    2011-01-01

    Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding views of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively

  14. Computer-Aided Modeling of Lipid Processing Technology

    DEFF Research Database (Denmark)

    Diaz Tovar, Carlos Axel

    2011-01-01

    increase along with growing interest in biofuels, the oleochemical industry faces in the upcoming years major challenges in terms of design and development of better products and more sustainable processes to make them. Computer-aided methods and tools for process synthesis, modeling and simulation...... are widely used for design, analysis, and optimization of processes in the chemical and petrochemical industries. These computer-aided tools have helped the chemical industry to evolve beyond commodities toward specialty chemicals and ‘consumer oriented chemicals based products’. Unfortunately...... to develop systematic computer-aided methods (property models) and tools (database) related to the prediction of the necessary physical properties suitable for design and analysis of processes employing lipid technologies. The methods and tools include: the development of a lipid-database (CAPEC...

  15. Intelligent Support for a Computer Aided Design Optimisation Cycle

    OpenAIRE

    B. Dolšak; M. Novak; J. Kaljun

    2006-01-01

    It is becoming more and more evident that  adding intelligence  to existing computer aids, such as computer aided design systems, can lead to significant improvements in the effective and reliable performance of various engineering tasks, including design optimisation. This paper presents three different intelligent modules to be applied within a computer aided design optimisation cycle to enable more intelligent and less experience-dependent design performance. 

  16. Robust Spacecraft Component Detection in Point Clouds

    Directory of Open Access Journals (Sweden)

    Quanmao Wei

    2018-03-01

    Full Text Available Automatic component detection of spacecraft can assist in on-orbit operation and space situational awareness. Spacecraft are generally composed of solar panels and cuboidal or cylindrical modules. These components can be simply represented by geometric primitives like plane, cuboid and cylinder. Based on this prior, we propose a robust automatic detection scheme to automatically detect such basic components of spacecraft in three-dimensional (3D point clouds. In the proposed scheme, cylinders are first detected in the iteration of the energy-based geometric model fitting and cylinder parameter estimation. Then, planes are detected by Hough transform and further described as bounded patches with their minimum bounding rectangles. Finally, the cuboids are detected with pair-wise geometry relations from the detected patches. After successive detection of cylinders, planar patches and cuboids, a mid-level geometry representation of the spacecraft can be delivered. We tested the proposed component detection scheme on spacecraft 3D point clouds synthesized by computer-aided design (CAD models and those recovered by image-based reconstruction, respectively. Experimental results illustrate that the proposed scheme can detect the basic geometric components effectively and has fine robustness against noise and point distribution density.

  17. Robust Spacecraft Component Detection in Point Clouds.

    Science.gov (United States)

    Wei, Quanmao; Jiang, Zhiguo; Zhang, Haopeng

    2018-03-21

    Automatic component detection of spacecraft can assist in on-orbit operation and space situational awareness. Spacecraft are generally composed of solar panels and cuboidal or cylindrical modules. These components can be simply represented by geometric primitives like plane, cuboid and cylinder. Based on this prior, we propose a robust automatic detection scheme to automatically detect such basic components of spacecraft in three-dimensional (3D) point clouds. In the proposed scheme, cylinders are first detected in the iteration of the energy-based geometric model fitting and cylinder parameter estimation. Then, planes are detected by Hough transform and further described as bounded patches with their minimum bounding rectangles. Finally, the cuboids are detected with pair-wise geometry relations from the detected patches. After successive detection of cylinders, planar patches and cuboids, a mid-level geometry representation of the spacecraft can be delivered. We tested the proposed component detection scheme on spacecraft 3D point clouds synthesized by computer-aided design (CAD) models and those recovered by image-based reconstruction, respectively. Experimental results illustrate that the proposed scheme can detect the basic geometric components effectively and has fine robustness against noise and point distribution density.

  18. Computing with high-resolution upwind schemes for hyperbolic equations

    International Nuclear Information System (INIS)

    Chakravarthy, S.R.; Osher, S.; California Univ., Los Angeles)

    1985-01-01

    Computational aspects of modern high-resolution upwind finite-difference schemes for hyperbolic systems of conservation laws are examined. An operational unification is demonstrated for constructing a wide class of flux-difference-split and flux-split schemes based on the design principles underlying total variation diminishing (TVD) schemes. Consideration is also given to TVD scheme design by preprocessing, the extension of preprocessing and postprocessing approaches to general control volumes, the removal of expansion shocks and glitches, relaxation methods for implicit TVD schemes, and a new family of high-accuracy TVD schemes. 21 references

  19. Performance of computer-aided detection in false-negative screening mammograms of breast cancers

    International Nuclear Information System (INIS)

    Han, Boo Kyung; Kim, Ji Young; Shin, Jung Hee; Choe, Yeon Hyeon

    2004-01-01

    To analyze retrospectively the abnormalities visible on the false-negative screening mammograms of patients with breast cancer and to determine the performance of computer-aided detection (CAD) in the detection of cancers. Of 108 consecutive cases of breast cancer diagnosed over a period of 6 years, of which previous screening mammograms were available, 32 retrospectively visible abnormalities (at which locations cancer later developed) were found in the previous mammograms, and which were originally reported as negative. These 32 patients ranged in age from 38 to 72 years (mean 52 years). We analyzed their previous mammographic findings, and assessed the ability of CAD to mark cancers in previous mammograms, according to the clinical presentation, the type of abnormalities and the mammographic parenchymal density. In these 32 previous mammograms of breast cancers (20 asymptomatic, 12 symptomatic), the retrospectively visible abnormalities were identified as densities in 22, calcifications in 8, and densities with calcifications in 2. CAD marked abnormalities in 20 (63%) of the 32 cancers with false-negative screening mammograms; 14 (70%) of the 20 subsequent screening-detected cancers, 5 (50%) of the 10 interval cancers, and 1 (50%) of the 2 cancers palpable after the screening interval. CAD marked 12 (50%) of the 24 densities and 9 (90%) of the 10 calcifications. CAD marked abnormalities in 7 (50%) of the 14 predominantly fatty breasts, and 13 (72%) of the 18 dense breasts. CAD-assisted diagnosis could potentially decrease the number of false-negative mammograms caused by the failure to recognize the cancer in the screening program, although its usefulness in the prevention of interval cancers appears to be limited

  20. Computer-aided detection of colorectal polyps: can it improve sensitivity of less-experienced readers? Preliminary findings.

    Science.gov (United States)

    Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael

    2007-10-01

    To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.

  1. Decision trees and integrated features for computer aided mammographic screening

    Energy Technology Data Exchange (ETDEWEB)

    Kegelmeyer, W.P. Jr.; Groshong, B.; Allmen, M.; Woods, K.

    1997-02-01

    Breast cancer is a serious problem, which in the United States causes 43,000 deaths a year, eventually striking 1 in 9 women. Early detection is the only effective countermeasure, and mass mammography screening is the only reliable means for early detection. Mass screening has many shortcomings which could be addressed by a computer-aided mammographic screening system. Accordingly, we have applied the pattern recognition methods developed in earlier investigations of speculated lesions in mammograms to the detection of microcalcifications and circumscribed masses, generating new, more rigorous and uniform methods for the detection of both those signs. We have also improved the pattern recognition methods themselves, through the development of a new approach to combinations of multiple classifiers.

  2. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Science.gov (United States)

    Sunwoo, Leonard; Kim, Young Jae; Choi, Seung Hong; Kim, Kwang-Gi; Kang, Ji Hee; Kang, Yeonah; Bae, Yun Jung; Yoo, Roh-Eul; Kim, Jihang; Lee, Kyong Joon; Lee, Seung Hyun; Choi, Byung Se; Jung, Cheolkyu; Sohn, Chul-Ho; Kim, Jae Hyoung

    2017-01-01

    To assess the effect of computer-aided detection (CAD) of brain metastasis (BM) on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR) imaging using follow-up imaging and consensus as the reference standard. The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents) interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP) per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC) method was used to determine the improvement in the diagnostic accuracy. The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM) of 0.874 (without CAD) vs. 0.898 (with CAD) according to JAFROC analysis (p reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p review the CAD results was approximately 72 sec (40% of the total review time). CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  3. Computer Aided Solvent Selection and Design Framework

    DEFF Research Database (Denmark)

    Mitrofanov, Igor; Conte, Elisa; Abildskov, Jens

    and computer-aided tools and methods for property prediction and computer-aided molecular design (CAMD) principles. This framework is applicable for solvent selection and design in product design as well as process design. The first module of the framework is dedicated to the solvent selection and design...... in terms of: physical and chemical properties (solvent-pure properties); Environment, Health and Safety (EHS) characteristic (solvent-EHS properties); operational properties (solvent–solute properties). 3. Performing the search. The search step consists of two stages. The first is a generation and property...... identification of solvent candidates using special software ProCAMD and ProPred, which are the implementations of computer-aided molecular techniques. The second consists of assigning the RS-indices following the reaction–solvent and then consulting the known solvent database and identifying the set of solvents...

  4. Computer Aided Drug Design: Success and Limitations.

    Science.gov (United States)

    Baig, Mohammad Hassan; Ahmad, Khurshid; Roy, Sudeep; Ashraf, Jalaluddin Mohammad; Adil, Mohd; Siddiqui, Mohammad Haris; Khan, Saif; Kamal, Mohammad Amjad; Provazník, Ivo; Choi, Inho

    2016-01-01

    Over the last few decades, computer-aided drug design has emerged as a powerful technique playing a crucial role in the development of new drug molecules. Structure-based drug design and ligand-based drug design are two methods commonly used in computer-aided drug design. In this article, we discuss the theory behind both methods, as well as their successful applications and limitations. To accomplish this, we reviewed structure based and ligand based virtual screening processes. Molecular dynamics simulation, which has become one of the most influential tool for prediction of the conformation of small molecules and changes in their conformation within the biological target, has also been taken into account. Finally, we discuss the principles and concepts of molecular docking, pharmacophores and other methods used in computer-aided drug design.

  5. Computer aided process control equipment at the Karlsruhe reprocessing pilot plant, WAK

    International Nuclear Information System (INIS)

    Winter, R.; Finsterwalder, L.; Gutzeit, G.; Reif, J.; Stollenwerk, A.H.; Weinbrecht, E.; Weishaupt, M.

    1991-01-01

    A computer aided process control system has been installed at the Karlsruhe Spent Fuel Reprocessing Plant, WAK. All necessary process control data of the first extraction cycle is collected via a data collection system and is displayed in suitable ways on a screen for the operator in charge of the unit. To aid verification of displayed data, various measurements are associated to each other using balance type process modeling. Thus, deviation of flowsheet conditions and malfunctioning of measuring equipment are easily detected. (orig.) [de

  6. Dual-scan technique for the customization of zirconia computer-aided design/computer-aided manufacturing frameworks.

    Science.gov (United States)

    Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes

    2013-09-01

    The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.

  7. Computer aided product design

    DEFF Research Database (Denmark)

    Constantinou, Leonidas; Bagherpour, Khosrow; Gani, Rafiqul

    1996-01-01

    A general methodology for Computer Aided Product Design (CAPD) with specified property constraints which is capable of solving a large range of problems is presented. The methodology employs the group contribution approach, generates acyclic, cyclic and aromatic compounds of various degrees......-liquid equilibria (LLE), solid-liquid equilibria (SLE) and gas solubility. Finally, a computer program based on the extended methodology has been developed and the results from five case studies highlighting various features of the methodology are presented....

  8. Perceptual Computing Aiding People in Making Subjective Judgments

    CERN Document Server

    Mendel, Jerry

    2010-01-01

    Explains for the first time how "computing with words" can aid in making subjective judgments. Lotfi Zadeh, the father of fuzzy logic, coined the phrase "computing with words" (CWW) to describe a methodology in which the objects of computation are words and propositions drawn from a natural language. Perceptual Computing explains how to implement CWW to aid in the important area of making subjective judgments, using a methodology that leads to an interactive device—a "Perceptual Computer"—that propagates random and linguistic uncertainties into the subjective judg

  9. Remote handling prospects. Computer aided remote handling

    International Nuclear Information System (INIS)

    Vertut, J.

    1984-01-01

    Mechanical manipulators, electrical control manipulators and computer aided manipulators were successively developed. The aim of computer aided manipulators is the realization of complex or tricky job in adverse environment but man is required for non routine work or for situation in evolution. French effort is developed in the frame of the project automation and advanced robotics and new problems have to be solved particularly at the interface man/machine [fr

  10. Improved mammographic interpretation of masses using computer-aided diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Leichter, I. [Dept. of Electro-Optics, Jerusalem College of Technology (Israel); Fields, S.; Novak, B. [Dept. of Radiology, Hadassah University Hospital, Mt. Scopus Jerusalem (Israel); Nirel, R. [Dept. of Statistics, Hebrew University of Jerusalem, Mt. Scopus, Jerusalem (Israel); Bamberger, P. [Dept. of Electronics, Jerusalem College of Technology, Jerusalem (Israel); Lederman, R. [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Buchbinder, S. [Department of Radiology, Montefiore Medical Center, University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States)

    2000-02-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p < 0.005) was found between features extracted by the CAD system for benign and malignant cases. Specificity of the CAD-assisted diagnosis improved significantly (p < 0.02) from 14 % for the conventional assessment to 50 %, and the positive predictive value increased from 0.47 to 0.62 (p < 0.04). The area under the ROC curve (A{sub z}) increased significantly (p < 0.001) from 0.66 for the conventional assessment to 0.81 for the CAD-assisted analysis. The A{sub z} for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that

  11. Development of computer-aided diagnosis systems in radiology

    International Nuclear Information System (INIS)

    Higashida, Yoshiharu; Arimura, Hidetaka; Kumazawa, Seiji; Morishita, Junji; Sakai, Shuji

    2006-01-01

    Computer-aided diagnosis (CAD) is a practice done by medical doctors based on computer image analysis as the second opinion, and CAD studies have been government-adopted projects. CAD is already on popular practice in the cancers of the breast by mammography, lung by flat plate and CT images, and large bowel by CT colonoscopy. This paper describes four examples of authors' actual CAD investigations. First, the temporal subtraction image analysis by CAD is for the detection of abnormality in the chest by radiographs taken at different times. Examples are shown in cases of interstitial pneumonia and lung cancer out of 34 patients with diffuse lung diseases. Second, development of CAD system is recorded for detection of aneurysm by the brain MR angiography (MRA). Third is the CAD detection of fascicles in cerebral white matters by the diffuse tensor MRI, which will help the surgery for brain tumors. Final is an automated patient recognition based on an image-matching technique using previous chest radiographs in the picture archiving and communication systems. This is on the radiograph giving biological fingerprints of the patients. CAD will be applied in a wider field of medicare not only in imaging technology. (T.I)

  12. Computer aided design for the nuclear industry

    International Nuclear Information System (INIS)

    Basson, Keith

    1986-01-01

    The paper concerns the new computer aided design (CAD) centre for the United Kingdom nuclear industry, and its applications. A description of the CAD system is given, including the current projects at the CAD centre. Typical applications of the 3D CAD plant based models, stress analysis studies, and the extraction of data from CAD drawings to produce associated documentation, are all described. Future developments using computer aided design systems are also considered. (U.K.)

  13. Identity based Encryption and Biometric Authentication Scheme for Secure Data Access in Cloud Computing

    DEFF Research Database (Denmark)

    Cheng, Hongbing; Rong, Chunming; Tan, Zheng-Hua

    2012-01-01

    Cloud computing will be a main information infrastructure in the future; it consists of many large datacenters which are usually geographically distributed and heterogeneous. How to design a secure data access for cloud computing platform is a big challenge. In this paper, we propose a secure data...... access scheme based on identity-based encryption and biometric authentication for cloud computing. Firstly, we describe the security concern of cloud computing and then propose an integrated data access scheme for cloud computing, the procedure of the proposed scheme include parameter setup, key...... distribution, feature template creation, cloud data processing and secure data access control. Finally, we compare the proposed scheme with other schemes through comprehensive analysis and simulation. The results show that the proposed data access scheme is feasible and secure for cloud computing....

  14. Clinical application of low-dose CT combined with computer-aided detection in lung cancer screening

    International Nuclear Information System (INIS)

    Xu Zushan; Hou Hongjun; Xu Yan; Ma Daqing

    2010-01-01

    Objective: To investigate the clinical value of chest low-dose CT (LDCT) combined with computer-aided detection (CAD) system for lung cancer screening in high risk population. Methods: Two hundred and nineteen healthy candidates underwent 64-slice LDCT scan. All images were reviewed in consensus by two radiologists with 15 years of thoracic CT diagnosis experience. Then the image data were analyzed with CAD alone. Finally images were reviewed by two radiologists with 5 years of CT diagnosis experience with and without CT Viewer software. The sensitivity, false positive rate of CAD for pulmonary nodule detection were calculated. SPSS 11.5 software and Chi-square test were used for the statistics. Results: Of 219 candidates ,104(47.5% ) were detected with lung nodules. There were 366 true nodules confirmed by the senior radiologists. The CAD system detected 271 (74.0%) true nodules and 424 false-positive nodules. The false-positive rate was 1.94/per case. The two junior radiologists indentifid 292 (79.8%), 286(78.1%) nodules without CAD and 336 (91.8%), 333 (91.0%) nodules with CAD respectively. There were significant differences for radiologists in indentifying nodules with or without CAD system (P<0.01). Conclusions: CAD is more sensitive than radiologists for indentifying the nodules in the central area or in the hilar region of the lung. While radiologists are more sensitive for the peripheral and sub-pleural nodules,or ground glass opacity nodules, or nodules smaller than 4 mm. CAD can not be used alone. The detection rate can be improved with the combination of radiologist and CAD in LDCT screen. (authors)

  15. Torsional strength of computer-aided design/computer-aided manufacturing-fabricated esthetic orthodontic brackets.

    Science.gov (United States)

    Alrejaye, Najla; Pober, Richard; Giordano Ii, Russell

    2017-01-01

    To fabricate orthodontic brackets from esthetic materials and determine their fracture resistance during archwire torsion. Computer-aided design/computer-aided manufacturing technology (Cerec inLab, Sirona) was used to mill brackets with a 0.018 × 0.025-inch slot. Materials used were Paradigm MZ100 and Lava Ultimate resin composite (3M ESPE), Mark II feldspathic porcelain (Vita Zahnfabrik), and In-Ceram YZ zirconia (Vita Zahnfabrik). Ten brackets of each material were subjected to torque by a 0.018 × 0.025-inch stainless steel archwire (G&H) using a specially designed apparatus. The average moments and degrees of torsion necessary to fracture the brackets were determined and compared with those of commercially available alumina brackets, Mystique MB (Dentsply GAC). The YZ brackets were statistically significantly stronger than any other tested material in their resistance to torsion (P brackets. Resistance of MZ100 and Lava Ultimate composite resin brackets to archwire torsion was comparable to commercially available alumina ceramic brackets.

  16. Computer-aided detection of lung nodules on multidetector CT in concurrent-reader and second-reader modes: A comparative study

    International Nuclear Information System (INIS)

    Matsumoto, Sumiaki; Ohno, Yoshiharu; Aoki, Takatoshi; Yamagata, Hitoshi; Nogami, Munenobu; Matsumoto, Keiko; Yamashita, Yoshiko; Sugimura, Kazuro

    2013-01-01

    Purpose: To compare the reading times and detection performances of radiologists in concurrent-reader and second-reader modes of computer-aided detection (CAD) for lung nodules on multidetector computed tomography (CT). Materials and Methods: Fifty clinical multidetector CT datasets containing nodules up to 20 mm in diameter were retrospectively collected. For the detection and rating of non-calcified nodules larger than 4 mm in diameter, 6 radiologists (3 experienced radiologists and 3 resident radiologists) independently interpreted these datasets twice, once with concurrent-reader CAD and once with second-reader CAD. The reference standard of nodules in the datasets was determined by the consensus of two experienced chest radiologists. The reading times and detection performances in the two modes of CAD were statistically compared, where jackknife free-response receiver operating characteristic (JAFROC) analysis was used for the comparison of detection performances. Results: Two hundreds and seven nodules constituted the reference standard. Reading time was significantly shorter in the concurrent-reader mode than in the second-reader mode, with the mean reading time for the 6 radiologists being 132 s with concurrent-reader CAD and 210 s with second-reader CAD (p < 0.01). JAFROC analysis revealed no significant difference between the detection performances in the two modes, with the average figure-of-merit value for the 6 radiologists being 0.70 with concurrent-reader CAD and 0.72 with second-reader CAD (p = 0.35). Conclusion: In CAD for lung nodules on multidetector CT, the concurrent-reader mode is more time-efficient than the second-reader mode, and there can be no significant difference between the two modes in terms of detection performance of radiologists

  17. TurbinAID

    International Nuclear Information System (INIS)

    Moradian, M.A.; Chow, M.P.; Osborne, R.L.; Jenkins, M.A.

    1991-01-01

    The Westinghouse Turbine Artificial Intelligence Diagnostics system or TurbinAID, can diagnose both thermodynamic and mechanical component anomalies within the turbine, and around the turbine cycle. any monitoring system can detect that a variable is in an abnormal state, but TurbinAID can also indicate the cause, and provide recommended corrective action(s). The TurbinAID Expert Systems utilize multiple sensor and variable inputs, and their interdependencies in the generation of a diagnosis. The system performs sensor validation as part of the data acquisition scheme. The TurbinAID system has been in operation for several years. This paper describes the monitoring and diagnostic functions provided by TurbinAID, and how the utility industry both nuclear and fossil, can utilize the system to enhance unit operation

  18. On the Value of Computer-aided Instruction: Thoughts after Teaching Sales Writing in a Computer Classroom.

    Science.gov (United States)

    Hagge, John

    1986-01-01

    Focuses on problems encountered with computer-aided writing instruction. Discusses conflicts caused by the computer classroom concept, some general paradoxes and ethical implications of computer-aided instruction. (EL)

  19. The interplay of attention economics and computer-aided detection marks in screening mammography

    Science.gov (United States)

    Schwartz, Tayler M.; Sridharan, Radhika; Wei, Wei; Lukyanchenko, Olga; Geiser, William; Whitman, Gary J.; Haygood, Tamara Miner

    2016-03-01

    Introduction: According to attention economists, overabundant information leads to decreased attention for individual pieces of information. Computer-aided detection (CAD) alerts radiologists to findings potentially associated with breast cancer but is notorious for creating an abundance of false-positive marks. We suspected that increased CAD marks do not lengthen mammogram interpretation time, as radiologists will selectively disregard these marks when present in larger numbers. We explore the relevance of attention economics in mammography by examining how the number of CAD marks affects interpretation time. Methods: We performed a retrospective review of bilateral digital screening mammograms obtained between January 1, 2011 and February 28, 2014, using only weekend interpretations to decrease distractions and the likelihood of trainee participation. We stratified data according to reader and used ANOVA to assess the relationship between number of CAD marks and interpretation time. Results: Ten radiologists, with median experience after residency of 12.5 years (range 6 to 24,) interpreted 1849 mammograms. When accounting for number of images, Breast Imaging Reporting and Data System category, and breast density, increasing numbers of CAD marks was correlated with longer interpretation time only for the three radiologists with the fewest years of experience (median 7 years.) Conclusion: For the 7 most experienced readers, increasing CAD marks did not lengthen interpretation time. We surmise that as CAD marks increase, the attention given to individual marks decreases. Experienced radiologists may rapidly dismiss larger numbers of CAD marks as false-positive, having learned that devoting extra attention to such marks does not improve clinical detection.

  20. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Directory of Open Access Journals (Sweden)

    Leonard Sunwoo

    Full Text Available To assess the effect of computer-aided detection (CAD of brain metastasis (BM on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR imaging using follow-up imaging and consensus as the reference standard.The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC method was used to determine the improvement in the diagnostic accuracy.The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM of 0.874 (without CAD vs. 0.898 (with CAD according to JAFROC analysis (p < 0.01. Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01. The additional time required to review the CAD results was approximately 72 sec (40% of the total review time.CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  1. A Scheme for Verification on Data Integrity in Mobile Multicloud Computing Environment

    Directory of Open Access Journals (Sweden)

    Laicheng Cao

    2016-01-01

    Full Text Available In order to verify the data integrity in mobile multicloud computing environment, a MMCDIV (mobile multicloud data integrity verification scheme is proposed. First, the computability and nondegeneracy of verification can be obtained by adopting BLS (Boneh-Lynn-Shacham short signature scheme. Second, communication overhead is reduced based on HVR (Homomorphic Verifiable Response with random masking and sMHT (sequence-enforced Merkle hash tree construction. Finally, considering the resource constraints of mobile devices, data integrity is verified by lightweight computing and low data transmission. The scheme improves shortage that mobile device communication and computing power are limited, it supports dynamic data operation in mobile multicloud environment, and data integrity can be verified without using direct source file block. Experimental results also demonstrate that this scheme can achieve a lower cost of computing and communications.

  2. A malware detection scheme based on mining format information.

    Science.gov (United States)

    Bai, Jinrong; Wang, Junfeng; Zou, Guozhong

    2014-01-01

    Malware has become one of the most serious threats to computer information system and the current malware detection technology still has very significant limitations. In this paper, we proposed a malware detection approach by mining format information of PE (portable executable) files. Based on in-depth analysis of the static format information of the PE files, we extracted 197 features from format information of PE files and applied feature selection methods to reduce the dimensionality of the features and achieve acceptable high performance. When the selected features were trained using classification algorithms, the results of our experiments indicate that the accuracy of the top classification algorithm is 99.1% and the value of the AUC is 0.998. We designed three experiments to evaluate the performance of our detection scheme and the ability of detecting unknown and new malware. Although the experimental results of identifying new malware are not perfect, our method is still able to identify 97.6% of new malware with 1.3% false positive rates.

  3. CAT -- computer aided testing for resonant inspection

    International Nuclear Information System (INIS)

    Foley, David K.

    1998-01-01

    Application of computer technology relates to inspection and quality control. The computer aided testing (CAT) can be used to analyze various NDT technologies, such as eddy current, ultrasonics, and resonant inspection

  4. Software For Computer-Aided Design Of Control Systems

    Science.gov (United States)

    Wette, Matthew

    1994-01-01

    Computer Aided Engineering System (CAESY) software developed to provide means to evaluate methods for dealing with users' needs in computer-aided design of control systems. Interpreter program for performing engineering calculations. Incorporates features of both Ada and MATLAB. Designed to be flexible and powerful. Includes internally defined functions, procedures and provides for definition of functions and procedures by user. Written in C language.

  5. Computer aided drug design

    Science.gov (United States)

    Jain, A.

    2017-08-01

    Computer based method can help in discovery of leads and can potentially eliminate chemical synthesis and screening of many irrelevant compounds, and in this way, it save time as well as cost. Molecular modeling systems are powerful tools for building, visualizing, analyzing and storing models of complex molecular structure that can help to interpretate structure activity relationship. The use of various techniques of molecular mechanics and dynamics and software in Computer aided drug design along with statistics analysis is powerful tool for the medicinal chemistry to synthesis therapeutic and effective drugs with minimum side effect.

  6. Call for a Computer-Aided Cancer Detection and Classification Research Initiative in Oman.

    Science.gov (United States)

    Mirzal, Andri; Chaudhry, Shafique Ahmad

    2016-01-01

    Cancer is a major health problem in Oman. It is reported that cancer incidence in Oman is the second highest after Saudi Arabia among Gulf Cooperation Council countries. Based on GLOBOCAN estimates, Oman is predicted to face an almost two-fold increase in cancer incidence in the period 2008-2020. However, cancer research in Oman is still in its infancy. This is due to the fact that medical institutions and infrastructure that play central roles in data collection and analysis are relatively new developments in Oman. We believe the country requires an organized plan and efforts to promote local cancer research. In this paper, we discuss current research progress in cancer diagnosis using machine learning techniques to optimize computer aided cancer detection and classification (CAD). We specifically discuss CAD using two major medical data, i.e., medical imaging and microarray gene expression profiling, because medical imaging like mammography, MRI, and PET have been widely used in Oman for assisting radiologists in early cancer diagnosis and microarray data have been proven to be a reliable source for differential diagnosis. We also discuss future cancer research directions and benefits to Oman economy for entering the cancer research and treatment business as it is a multi-billion dollar industry worldwide.

  7. COMPUTER-AIDED DATA ACQUISITION FOR COMBUSTION EXPERIMENTS

    Science.gov (United States)

    The article describes the use of computer-aided data acquisition techniques to aid the research program of the Combustion Research Branch (CRB) of the U.S. EPA's Air and Energy Engineering Research Laboratory (AEERL) in Research Triangle Park, NC, in particular on CRB's bench-sca...

  8. Home-use cancer detecting band aid

    Science.gov (United States)

    Zalevsky, Zeev; Rudnitsky, Arkady; Sheinman, Victor; Tzoy, Andrey; Toktosunov, Aitmamat; Adashov, Arkady

    2016-03-01

    In this paper we present a novel concept in which special band aid is developed for early detection of cancer. The band aid contains an array of micro needles with small detection array connected to each needle which inspects the color of the surface of the skin versus time after being pinched with the needles. We were able to show in pre-clinical trials that the color varies differently if the skin is close to tumor tissue.

  9. Computer aided safety analysis

    International Nuclear Information System (INIS)

    1988-05-01

    The document reproduces 20 selected papers from the 38 papers presented at the Technical Committee/Workshop on Computer Aided Safety Analysis organized by the IAEA in co-operation with the Institute of Atomic Energy in Otwock-Swierk, Poland on 25-29 May 1987. A separate abstract was prepared for each of these 20 technical papers. Refs, figs and tabs

  10. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT.

    Science.gov (United States)

    Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P

    2013-01-01

    The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.

  11. A Computationally Intelligent Approach to the Detection of Wormhole Attacks in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Mohammad Nurul Afsar Shaon

    2017-05-01

    Full Text Available A wormhole attack is one of the most critical and challenging security threats for wireless sensor networks because of its nature and ability to perform concealed malicious activities. This paper proposes an innovative wormhole detection scheme to detect wormhole attacks using computational intelligence and an artificial neural network (ANN. Most wormhole detection schemes reported in the literature assume the sensors are uniformly distributed in a network, and, furthermore, they use statistical and topological information and special hardware for their detection. However, these schemes may perform poorly in non-uniformly distributed networks, and, moreover, they may fail to defend against “out of band” and “in band” wormhole attacks. The aim of the proposed research is to develop a detection scheme that is able to detect all kinds of wormhole attacks in both uniformly and non-uniformly distributed sensor networks. Furthermore, the proposed research does not require any special hardware and causes no significant network overhead throughout the network. Most importantly, the probable location of the malicious nodes can be identified by the proposed ANN based detection scheme. We evaluate the efficacy of the proposed detection scheme in terms of detection accuracy, false positive rate, and false negative rate. The performance of the proposed algorithm is also compared with other machine learning techniques (i.e. SVM and regularized nonlinear logistic regression (LR based detection models. The simulation results show that proposed ANN based algorithm outperforms the SVM or LR based detection schemes in terms of detection accuracy, false positive rate, and false negative rates.

  12. Cognitive models and computer aids for nuclear plant control room operators

    International Nuclear Information System (INIS)

    Sheridan, T.B.

    1982-01-01

    This paper reviews what is usually meant by a cognitive model of a control room operator in a nuclear power plant. It emphasizes the idea of internal (that is, mental) representation of external events and the use of such representation for the cognitive steps of attending, recognizing or learning, assessing and deciding. As computers play an increasingly important role in nuclear power plants, especially as cognitive aids to human supervisors of highly automated control systems, it is important that the software and computer interface characteristics be compatible with the operator's internal model. Specific examples discussed in this paper are in the monitoring and prediction of the plant state and in the detection and diagnosis of failures. Current trends in SPDS (safety parameter display system) and failure detection/location systems will be discussed in this regard

  13. Adhesive Bonding to Computer-aided Design/ Computer-aided Manufacturing Esthetic Dental Materials: An Overview.

    Science.gov (United States)

    Awad, Mohamed Moustafa; Alqahtani, H; Al-Mudahi, A; Murayshed, M S; Alrahlah, A; Bhandi, Shilpa H

    2017-07-01

    To review the adhesive bonding to different computer-aided design/computer-aided manufacturing (CAD/CAM) esthetic restorative materials. The use of CAD/CAM esthetic restorative materials has gained popularity in recent years. Several CAD/ CAM esthetic restorative materials are commercially available. Adhesive bonding is a major determinant of success of CAD/ CAM restorations. Review result: An account of the currently available bonding strategies are discussed with their rationale in various CAD/ CAM materials. Different surface treatment methods as well as adhesion promoters can be used to achieve reliable bonding of CAD/CAM restorative materials. Selection of bonding strategy to such material is determined based on its composition. Further evidence is required to evaluate the effect of new surface treatment methods, such as nonthermal atmospheric plasma and self-etching ceramic primer on bonding to different dental ceramics. An understanding of the currently available bonding strategies to CA/CAM materials can help the clinician to select the most indicated system for each category of materials.

  14. [Key points for esthetic rehabilitation of anterior teeth using chair-side computer aided design and computer aided manufacture technique].

    Science.gov (United States)

    Yang, J; Feng, H L

    2018-04-09

    With the rapid development of the chair-side computer aided design and computer aided manufacture (CAD/CAM) technology, its accuracy and operability of have been greatly improved in recent years. Chair-side CAD/CAM system may produce all kinds of indirect restorations, and has the advantages of rapid, accurate and stable production. It has become the future development direction of Stomatology. This paper describes the clinical application of the chair-side CAD/CAM technology for anterior aesthetic restorations from the aspects of shade and shape.

  15. Money Laundering Detection Framework to Link the Disparate and Evolving Schemes

    Directory of Open Access Journals (Sweden)

    Murad Mehmet

    2013-09-01

    Full Text Available Money launderers hide traces of their transactions with the involvement of entities that participate in sophisticated schemes. Money laundering detection requires unraveling concealed connections among multiple but seemingly unrelated human money laundering networks, ties among actors of those schemes, and amounts of funds transferred among those entities. The link among small networks, either financial or social, is the primary factor that facilitates money laundering. Hence, the analysis of relations among money laundering networks is required to present the full structure of complex schemes. We propose a framework that uses sequence matching, case-based analysis, social network analysis, and complex event processing to detect money laundering. Our framework captures an ongoing single scheme as an event, and associations among such ongoing sequence of events to capture complex relationships among evolving money laundering schemes. The framework can detect associated multiple money laundering networks even in the absence of some evidence. We validated the accuracy of detecting evolving money laundering schemes using a multi-phases test methodology. Our test used data generated from real-life cases, and extrapolated to generate more data from real-life schemes generator that we implemented.

  16. Computer-aided detection of masses in digital tomosynthesis mammography: Comparison of three approaches

    International Nuclear Information System (INIS)

    Chan Heangping; Wei Jun; Zhang Yiheng; Helvie, Mark A.; Moore, Richard H.; Sahiner, Berkman; Hadjiiski, Lubomir; Kopans, Daniel B.

    2008-01-01

    The authors are developing a computer-aided detection (CAD) system for masses on digital breast tomosynthesis mammograms (DBT). Three approaches were evaluated in this study. In the first approach, mass candidate identification and feature analysis are performed in the reconstructed three-dimensional (3D) DBT volume. A mass likelihood score is estimated for each mass candidate using a linear discriminant analysis (LDA) classifier. Mass detection is determined by a decision threshold applied to the mass likelihood score. A free response receiver operating characteristic (FROC) curve that describes the detection sensitivity as a function of the number of false positives (FPs) per breast is generated by varying the decision threshold over a range. In the second approach, prescreening of mass candidate and feature analysis are first performed on the individual two-dimensional (2D) projection view (PV) images. A mass likelihood score is estimated for each mass candidate using an LDA classifier trained for the 2D features. The mass likelihood images derived from the PVs are backprojected to the breast volume to estimate the 3D spatial distribution of the mass likelihood scores. The FROC curve for mass detection can again be generated by varying the decision threshold on the 3D mass likelihood scores merged by backprojection. In the third approach, the mass likelihood scores estimated by the 3D and 2D approaches, described above, at the corresponding 3D location are combined and evaluated using FROC analysis. A data set of 100 DBT cases acquired with a GE prototype system at the Breast Imaging Laboratory in the Massachusetts General Hospital was used for comparison of the three approaches. The LDA classifiers with stepwise feature selection were designed with leave-one-case-out resampling. In FROC analysis, the CAD system for detection in the DBT volume alone achieved test sensitivities of 80% and 90% at average FP rates of 1.94 and 3.40 per breast, respectively. With the

  17. Selection of an optimal neural network architecture for computer-aided detection of microcalcifications - Comparison of automated optimization techniques

    International Nuclear Information System (INIS)

    Gurcan, Metin N.; Sahiner, Berkman; Chan Heangping; Hadjiiski, Lubomir; Petrick, Nicholas

    2001-01-01

    Many computer-aided diagnosis (CAD) systems use neural networks (NNs) for either detection or classification of abnormalities. Currently, most NNs are 'optimized' by manual search in a very limited parameter space. In this work, we evaluated the use of automated optimization methods for selecting an optimal convolution neural network (CNN) architecture. Three automated methods, the steepest descent (SD), the simulated annealing (SA), and the genetic algorithm (GA), were compared. We used as an example the CNN that classifies true and false microcalcifications detected on digitized mammograms by a prescreening algorithm. Four parameters of the CNN architecture were considered for optimization, the numbers of node groups and the filter kernel sizes in the first and second hidden layers, resulting in a search space of 432 possible architectures. The area A z under the receiver operating characteristic (ROC) curve was used to design a cost function. The SA experiments were conducted with four different annealing schedules. Three different parent selection methods were compared for the GA experiments. An available data set was split into two groups with approximately equal number of samples. By using the two groups alternately for training and testing, two different cost surfaces were evaluated. For the first cost surface, the SD method was trapped in a local minimum 91% (392/432) of the time. The SA using the Boltzman schedule selected the best architecture after evaluating, on average, 167 architectures. The GA achieved its best performance with linearly scaled roulette-wheel parent selection; however, it evaluated 391 different architectures, on average, to find the best one. The second cost surface contained no local minimum. For this surface, a simple SD algorithm could quickly find the global minimum, but the SA with the very fast reannealing schedule was still the most efficient. The same SA scheme, however, was trapped in a local minimum on the first cost

  18. Computer-aided detection of early cancer in the esophagus using HD endoscopy images

    Science.gov (United States)

    van der Sommen, Fons; Zinger, Svitlana; Schoon, Erik J.; de With, Peter H. N.

    2013-02-01

    Esophageal cancer is the fastest rising type of cancer in the Western world. The recent development of High-Definition (HD) endoscopy has enabled the specialist physician to identify cancer at an early stage. Nevertheless, it still requires considerable effort and training to be able to recognize these irregularities associated with early cancer. As a first step towards a Computer-Aided Detection (CAD) system that supports the physician in finding these early stages of cancer, we propose an algorithm that is able to identify irregularities in the esophagus automatically, based on HD endoscopic images. The concept employs tile-based processing, so our system is not only able to identify that an endoscopic image contains early cancer, but it can also locate it. The identification is based on the following steps: (1) preprocessing, (2) feature extraction with dimensionality reduction, (3) classification. We evaluate the detection performance in RGB, HSI and YCbCr color space using the Color Histogram (CH) and Gabor features and we compare with other well-known features to describe texture. For classification, we employ a Support Vector Machine (SVM) and evaluate its performance using different parameters and kernel functions. In experiments, our system achieves a classification accuracy of 95.9% on 50×50 pixel tiles of tumorous and normal tissue and reaches an Area Under the Curve (AUC) of 0.990. In 22 clinical examples our algorithm was able to identify all (pre-)cancerous regions and annotate those regions reasonably well. The experimental and clinical validation are considered promising for a CAD system that supports the physician in finding early stage cancer.

  19. Multimedia Image Technology and Computer Aided Manufacturing Engineering Analysis

    Science.gov (United States)

    Nan, Song

    2018-03-01

    Since the reform and opening up, with the continuous development of science and technology in China, more and more advanced science and technology have emerged under the trend of diversification. Multimedia imaging technology, for example, has a significant and positive impact on computer aided manufacturing engineering in China. From the perspective of scientific and technological advancement and development, the multimedia image technology has a very positive influence on the application and development of computer-aided manufacturing engineering, whether in function or function play. Therefore, this paper mainly starts from the concept of multimedia image technology to analyze the application of multimedia image technology in computer aided manufacturing engineering.

  20. Reproducibility of computer-aided detection system in digital mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Cho, Nariya; Cha, Joo Hee; Chung, Hye Kyung; Lee, Sin Ho; Cho, Kyung Soo; Kim, Sun Mi; Moon, Woo Kyung

    2005-01-01

    To evaluate the reproducibility of the computer-aided detection (CAD) system for digital mammograms. We applied the CAD system (ImageChecker M1000-DM, version 3.1; R2 Technology) to full field digital mammograms. These mammograms were taken twice at an interval of 10-45 days (mean:25 days) for 34 preoperative patients (breast cancer n=27, benign disease n=7, age range:20-66 years, mean age:47.9 years). On the mammograms, lesions were visible in 19 patients and these were depicted as 15 masses and 12 calcification clusters. We analyzed the sensitivity, the false positive rate (FPR) and the reproducibility of the CAD marks. The broader sensitivities of the CAD system were 80% (12 of 15), 67%(10 of 15) for masses and those for calcification clusters were 100% (12 of 12). The strict sensitivities were 50% (15 of 30) and 50% (15 of 30) for masses and 92% (22 of 24) and 79% (19 of 24) for the clusters. The FPR for the masses was 0.21-0.22/image, the FPR for the clusters was 0.03-0.04/image and the total FPR was 0.24-0.26/image. Among 132 mammography images, the identical images regardless of the existence of CAD marks were 59% (78 of 132), and the identical images with CAD marks were 22% (15 of 69). The reproducibility of the CAD marks for the true positive mass was 67% (12 of 18) and 71% (17 of 24) for the true positive cluster. The reproducibility of CAD marks for the false positive mass was 8% (4 of 53), and the reproducibility of CAD marks for the false positive clusters was 14% (1 of 7). The reproducibility of the total mass marks was 23% (16 of 71), and the reproducibility of the total cluster marks was 58% (18 of 31). CAD system showed higher sensitivity and reproducibility of CAD marks for the calcification clusters which are related to breast cancer. Yet the overall reproducibility of CAD marks was low; therefore, the CAD system must be applied considering this limitation

  1. Integrated computer-aided design using minicomputers

    Science.gov (United States)

    Storaasli, O. O.

    1980-01-01

    Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), a highly interactive software, has been implemented on minicomputers at the NASA Langley Research Center. CAD/CAM software integrates many formerly fragmented programs and procedures into one cohesive system; it also includes finite element modeling and analysis, and has been interfaced via a computer network to a relational data base management system and offline plotting devices on mainframe computers. The CAD/CAM software system requires interactive graphics terminals operating at a minimum of 4800 bits/sec transfer rate to a computer. The system is portable and introduces 'interactive graphics', which permits the creation and modification of models interactively. The CAD/CAM system has already produced designs for a large area space platform, a national transonic facility fan blade, and a laminar flow control wind tunnel model. Besides the design/drafting element analysis capability, CAD/CAM provides options to produce an automatic program tooling code to drive a numerically controlled (N/C) machine. Reductions in time for design, engineering, drawing, finite element modeling, and N/C machining will benefit productivity through reduced costs, fewer errors, and a wider range of configuration.

  2. Correction of facial and mandibular asymmetry using a computer aided design/computer aided manufacturing prefabricated titanium implant.

    Science.gov (United States)

    Watson, Jason; Hatamleh, Muhanad; Alwahadni, Ahed; Srinivasan, Dilip

    2014-05-01

    Patients with significant craniofacial asymmetry may have functional problems associated with their occlusion and aesthetic concerns related to the imbalance in soft and hard tissue profiles. This report details a case of facial asymmetry secondary to left mandible angle deficiency due to undergoing previous radiotherapy. We describe the correction of the bony deformity using computer aided design/computer aided manufacturing custom-made titanium onlay using novel direct metal laser sintering. The direct metal laser sintering onlay proved a very accurate operative fit and showed a good aesthetic correction of the bony defect with no reported complications postoperatively. It is a useful low-morbidity technique, and there is no resorption or associated donor-site complications.

  3. MIMO transmit scheme based on morphological perceptron with competitive learning.

    Science.gov (United States)

    Valente, Raul Ambrozio; Abrão, Taufik

    2016-08-01

    This paper proposes a new multi-input multi-output (MIMO) transmit scheme aided by artificial neural network (ANN). The morphological perceptron with competitive learning (MP/CL) concept is deployed as a decision rule in the MIMO detection stage. The proposed MIMO transmission scheme is able to achieve double spectral efficiency; hence, in each time-slot the receiver decodes two symbols at a time instead one as Alamouti scheme. Other advantage of the proposed transmit scheme with MP/CL-aided detector is its polynomial complexity according to modulation order, while it becomes linear when the data stream length is greater than modulation order. The performance of the proposed scheme is compared to the traditional MIMO schemes, namely Alamouti scheme and maximum-likelihood MIMO (ML-MIMO) detector. Also, the proposed scheme is evaluated in a scenario with variable channel information along the frame. Numerical results have shown that the diversity gain under space-time coding Alamouti scheme is partially lost, which slightly reduces the bit-error rate (BER) performance of the proposed MP/CL-NN MIMO scheme. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. CrowdAidRepair: A Crowd-Aided Interactive Data Repairing Method

    KAUST Repository

    Zhou, Jian

    2016-03-25

    Data repairing aims at discovering and correcting erroneous data in databases. Traditional methods relying on predefined quality rules to detect the conflict between data may fail to choose the right way to fix the detected conflict. Recent efforts turn to use the power of crowd in data repairing, but the crowd power has its own drawbacks such as high human intervention cost and inevitable low efficiency. In this paper, we propose a crowd-aided interactive data repairing method which takes the advantages of both rule-based method and crowd-based method. Particularly, we investigate the interaction between crowd-based repairing and rule-based repairing, and show that by doing crowd-based repairing to a small portion of values, we can greatly improve the repairing quality of the rule-based repairing method. Although we prove that the optimal interaction scheme using the least number of values for crowd-based repairing to maximize the imputation recall is not feasible to be achieved, still, our proposed solution identifies an efficient scheme through investigating the inconsistencies and the dependencies between values in the repairing process. Our empirical study on three data collections demonstrates the high repairing quality of CrowdAidRepair, as well as the efficiency of the generated interaction scheme over baselines.

  5. Computer-aided detection system for masses in automated whole breast ultrasonography: development and evaluation of the effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeoung Hyun [Dept. of Radiology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Cha, Joo Hee; Kim, Nam Kug; Chang, Young Jun; Kim, Hak Hee [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ko, Myung Su [Health Screening and Promotion Center, Asan Medical Center, Seoul (Korea, Republic of); Choi, Young Wook [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2014-04-15

    The aim of this study was to evaluate the performance of a proposed computer-aided detection (CAD) system in automated breast ultrasonography (ABUS). Eighty-nine two-dimensional images (20 cysts, 42 benign lesions, and 27 malignant lesions) were obtained from 47 patients who underwent ABUS (ACUSON S2000). After boundary detection and removal, we detected mass candidates by using the proposed adjusted Otsu's threshold; the threshold was adaptive to the variations of pixel intensities in an image. Then, the detected candidates were segmented. Features of the segmented objects were extracted and used for training/testing in the classification. In our study, a support vector machine classifier was adopted. Eighteen features were used to determine whether the candidates were true lesions or not. A five-fold cross validation was repeated 20 times for the performance evaluation. The sensitivity and the false positive rate per image were calculated, and the classification accuracy was evaluated for each feature. In the classification step, the sensitivity of the proposed CAD system was 82.67% (SD, 0.02%). The false positive rate was 0.26 per image. In the detection/segmentation step, the sensitivities for benign and malignant mass detection were 90.47% (38/42) and 92.59% (25/27), respectively. In the five-fold cross-validation, the standard deviation of pixel intensities for the mass candidates was the most frequently selected feature, followed by the vertical position of the centroids. In the univariate analysis, each feature had 50% or higher accuracy. The proposed CAD system can be used for lesion detection in ABUS and may be useful in improving the screening efficiency.

  6. Computer aided plant engineering: An analysis and suggestions for computer use

    International Nuclear Information System (INIS)

    Leinemann, K.

    1979-09-01

    To get indications to and boundary conditions for computer use in plant engineering, an analysis of the engineering process was done. The structure of plant engineering is represented by a network of substaks and subsets of data which are to be manipulated. Main tool for integration of CAD-subsystems in plant engineering should be a central database which is described by characteristical requirements and a possible simple conceptual schema. The main features of an interactive system for computer aided plant engineering are shortly illustrated by two examples. The analysis leads to the conclusion, that an interactive graphic system for manipulation of net-like structured data, usable for various subtasks, should be the base for computer aided plant engineering. (orig.) [de

  7. PHACK: An Efficient Scheme for Selective Forwarding Attack Detection in WSNs

    Directory of Open Access Journals (Sweden)

    Anfeng Liu

    2015-12-01

    Full Text Available In this paper, a Per-Hop Acknowledgement (PHACK-based scheme is proposed for each packet transmission to detect selective forwarding attacks. In our scheme, the sink and each node along the forwarding path generate an acknowledgement (ACK message for each received packet to confirm the normal packet transmission. The scheme, in which each ACK is returned to the source node along a different routing path, can significantly increase the resilience against attacks because it prevents an attacker from compromising nodes in the return routing path, which can otherwise interrupt the return of nodes’ ACK packets. For this case, the PHACK scheme also has better potential to detect abnormal packet loss and identify suspect nodes as well as better resilience against attacks. Another pivotal issue is the network lifetime of the PHACK scheme, as it generates more acknowledgements than previous ACK-based schemes. We demonstrate that the network lifetime of the PHACK scheme is not lower than that of other ACK-based schemes because the scheme just increases the energy consumption in non-hotspot areas and does not increase the energy consumption in hotspot areas. Moreover, the PHACK scheme greatly simplifies the protocol and is easy to implement. Both theoretical and simulation results are given to demonstrate the effectiveness of the proposed scheme in terms of high detection probability and the ability to identify suspect nodes.

  8. Computer-aided detection of masses in full-field digital mammography using screen-film mammograms for training

    International Nuclear Information System (INIS)

    Kallenberg, Michiel; Karssemeijer, Nico

    2008-01-01

    It would be of great value when available databases of screen-film mammography (SFM) images can be used to train full-field digital mammography (FFDM) computer-aided detection (CAD) systems, as compilation of new databases is costly. In this paper, we investigate this possibility. Firstly, we develop a method that converts an FFDM image into an SFM-like representation. In this conversion method, we establish a relation between exposure and optical density by simulation of an automatic exposure control unit. Secondly, we investigate the effects of using the SFM images as training samples compared to training with FFDM images. Our FFDM database consisted of 266 cases, of which 102 were biopsy-proven malignant masses and 164 normals. The images were acquired with systems of two different manufacturers. We found that, when we trained our FFDM CAD system with a small number of images, training with FFDM images, using a five-fold crossvalidation procedure, outperformed training with SFM images. However, when the full SFM database, consisting of 348 abnormal cases (including 204 priors) and 810 normal cases, was used for training, SFM training outperformed FFDMA training. These results show that an existing CAD system for detection of masses in SFM can be used for FFDM images without retraining.

  9. Screening mammography-detected cancers: the sensitivity of the computer-aided detection system as applied to full-field digital mammography

    International Nuclear Information System (INIS)

    Yang, Sang Kyu; Cho, Nariya; Ko, Eun Sook; Kim, Do Yeon; Moon, Woo Kyung

    2006-01-01

    We wanted to evaluate the sensitivity of the computer-aided detection (CAD) system for performing full-field digital mammography (FFDM) on the breast cancers that were originally detected by screening mammography. The CAD system (Image Checker v3.1, R2 Technology, Los Altos, Calif.) together with a full-field digital mammography system (Senographe 2000D, GE Medical Systems, Buc, France) was prospectively applied to the mammograms of 70 mammographically detected breast cancer patients (age range, 37-69; median age, 51 years) who had negative findings on their clinical examinations. The sensitivity of the CAD system, according to histopathologic findings and radiologic primary features (i.e, mass, microcalcifications or mass with microcalcifications) and also the false-positive marking rate were then determined. The CAD system correctly depicted 67 of 70 breast cancer lesions (97.5%). The CAD system marked 29 of 30 breast cancers that presented with microcalcifications only (sensitivity 96.7%) and all 18 breast cancers the presented with mass together with microcalcifications (sensitivity 100%). Twenty of the 22 lesions that appeared as a mass only were marked correctly by the CAD system (sensitivity 90.9%). The CAD system correctly depicted all 22 lesions of ductal carcinoma in situ (sensitivity: 100%), all 13 lesions of invasive ductal carcinoma with ductal carcinoma in situ (sensitivity: 100%) and the 1 lesion of invasive lobular carcinoma (sensitivity: 100%). Thirty one of the 34 lesions of invasive ductal carcinoma were marked correctly by the CAD system (sensitivity: 91.8%). The rate of false-positive marks was 0.21 mass marks per image and 0.16 microcalcification marks per image. The overall rate of false-positive marks was 0.37 per image. The CAD system using FFDM is useful for the detection of asymptomatic breast cancers, and it has a high overall tumor detection rate. The false negative cases were found in relatively small invasive ductal carcinoma

  10. Screening mammography-detected cancers: the sensitivity of the computer-aided detection system as applied to full-field digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Sang Kyu; Cho, Nariya; Ko, Eun Sook; Kim, Do Yeon; Moon, Woo Kyung [College of Medicine Seoul National University and The Insititute of Radiation Medicine, Seoul National University Research Center, Seoul (Korea, Republic of)

    2006-04-15

    We wanted to evaluate the sensitivity of the computer-aided detection (CAD) system for performing full-field digital mammography (FFDM) on the breast cancers that were originally detected by screening mammography. The CAD system (Image Checker v3.1, R2 Technology, Los Altos, Calif.) together with a full-field digital mammography system (Senographe 2000D, GE Medical Systems, Buc, France) was prospectively applied to the mammograms of 70 mammographically detected breast cancer patients (age range, 37-69; median age, 51 years) who had negative findings on their clinical examinations. The sensitivity of the CAD system, according to histopathologic findings and radiologic primary features (i.e, mass, microcalcifications or mass with microcalcifications) and also the false-positive marking rate were then determined. The CAD system correctly depicted 67 of 70 breast cancer lesions (97.5%). The CAD system marked 29 of 30 breast cancers that presented with microcalcifications only (sensitivity 96.7%) and all 18 breast cancers the presented with mass together with microcalcifications (sensitivity 100%). Twenty of the 22 lesions that appeared as a mass only were marked correctly by the CAD system (sensitivity 90.9%). The CAD system correctly depicted all 22 lesions of ductal carcinoma in situ (sensitivity: 100%), all 13 lesions of invasive ductal carcinoma with ductal carcinoma in situ (sensitivity: 100%) and the 1 lesion of invasive lobular carcinoma (sensitivity: 100%). Thirty one of the 34 lesions of invasive ductal carcinoma were marked correctly by the CAD system (sensitivity: 91.8%). The rate of false-positive marks was 0.21 mass marks per image and 0.16 microcalcification marks per image. The overall rate of false-positive marks was 0.37 per image. The CAD system using FFDM is useful for the detection of asymptomatic breast cancers, and it has a high overall tumor detection rate. The false negative cases were found in relatively small invasive ductal carcinoma.

  11. To the problem of reliability standardization in computer-aided manufacturing at NPP units

    International Nuclear Information System (INIS)

    Yastrebenetskij, M.A.; Shvyryaev, Yu.V.; Spektor, L.I.; Nikonenko, I.V.

    1989-01-01

    The problems of reliability standardization in computer-aided manufacturing of NPP units considering the following approaches: computer-aided manufacturing of NPP units as a part of automated technological complex; computer-aided manufacturing of NPP units as multi-functional system, are analyzed. Selection of the composition of reliability indeces for computer-aided manufacturing of NPP units for each of the approaches considered is substantiated

  12. The Impact of Machine Translation and Computer-aided Translation on Translators

    Science.gov (United States)

    Peng, Hao

    2018-03-01

    Under the context of globalization, communications between countries and cultures are becoming increasingly frequent, which make it imperative to use some techniques to help translate. This paper is to explore the influence of computer-aided translation on translators, which is derived from the field of the computer-aided translation (CAT) and machine translation (MT). Followed by an introduction to the development of machine and computer-aided translation, it then depicts the technologies practicable to translators, which are trying to analyze the demand of designing the computer-aided translation so far in translation practice, and optimize the designation of computer-aided translation techniques, and analyze its operability in translation. The findings underline the advantages and disadvantages of MT and CAT tools, and the serviceability and future development of MT and CAT technologies. Finally, this thesis probes into the impact of these new technologies on translators in hope that more translators and translation researchers can learn to use such tools to improve their productivity.

  13. Computer aided instrumented Charpy test applied dynamic fracture toughness evaluation system

    International Nuclear Information System (INIS)

    Kobayashi, Toshiro; Niinomi, Mitsuo

    1986-01-01

    Micro computer aided data treatment system and personal computer aided data analysis system were applied to the traditional instrumented Charpy impact test system. The analysis of Charpy absorbed energy (E i , E p , E t ) and load (P y , P m ), and the evaluation of dynamic toughness through whole fracture process, i.e. J Id , J R curve and T mat was examined using newly developed computer aided instrumented Charpy impact test system. E i , E p , E t , P y and P m were effectively analyzed using moving average method and printed out automatically by micro computer aided data treatment system. J Id , J R curve and T mat could be measured by stop block test method. Then, J Id , J R curve and T mat were effectively estimated using compliance changing rate method and key curve method on the load-load point displacement curve of single fatigue cracked specimen by personal computer aided data analysis system. (author)

  14. Computer-aided engineering of semiconductor integrated circuits

    Science.gov (United States)

    Meindl, J. D.; Dutton, R. W.; Gibbons, J. F.; Helms, C. R.; Plummer, J. D.; Tiller, W. A.; Ho, C. P.; Saraswat, K. C.; Deal, B. E.; Kamins, T. I.

    1980-07-01

    Economical procurement of small quantities of high performance custom integrated circuits for military systems is impeded by inadequate process, device and circuit models that handicap low cost computer aided design. The principal objective of this program is to formulate physical models of fabrication processes, devices and circuits to allow total computer-aided design of custom large-scale integrated circuits. The basic areas under investigation are (1) thermal oxidation, (2) ion implantation and diffusion, (3) chemical vapor deposition of silicon and refractory metal silicides, (4) device simulation and analytic measurements. This report discusses the fourth year of the program.

  15. Computer-Aided Parts Estimation

    OpenAIRE

    Cunningham, Adam; Smart, Robert

    1993-01-01

    In 1991, Ford Motor Company began deployment of CAPE (computer-aided parts estimating system), a highly advanced knowledge-based system designed to generate, evaluate, and cost automotive part manufacturing plans. cape is engineered on an innovative, extensible, declarative process-planning and estimating knowledge representation language, which underpins the cape kernel architecture. Many manufacturing processes have been modeled to date, but eventually every significant process in motor veh...

  16. Multi-criteria decision aid approach for the selection of the best compromise management scheme for ELVs: the case of Cyprus.

    Science.gov (United States)

    Mergias, I; Moustakas, K; Papadopoulos, A; Loizidou, M

    2007-08-25

    Each alternative scheme for treating a vehicle at its end of life has its own consequences from a social, environmental, economic and technical point of view. Furthermore, the criteria used to determine these consequences are often contradictory and not equally important. In the presence of multiple conflicting criteria, an optimal alternative scheme never exists. A multiple-criteria decision aid (MCDA) method to aid the Decision Maker (DM) in selecting the best compromise scheme for the management of End-of-Life Vehicles (ELVs) is presented in this paper. The constitution of a set of alternatives schemes, the selection of a list of relevant criteria to evaluate these alternative schemes and the choice of an appropriate management system are also analyzed in this framework. The proposed procedure relies on the PROMETHEE method which belongs to the well-known family of multiple criteria outranking methods. For this purpose, level, linear and Gaussian functions are used as preference functions.

  17. Prerequisites for Computer-Aided Cognitive Rehabilitation.

    Science.gov (United States)

    Legrand, Colette

    1989-01-01

    This paper describes computer-aided cognitive rehabilitation for mentally deficient persons. It lists motor, cognitive, emotional, and educational prerequisites to such rehabilitation and states advantages and disadvantages in using the prerequisites. (JDD)

  18. Computer-aided instruction system

    International Nuclear Information System (INIS)

    Teneze, Jean Claude

    1968-01-01

    This research thesis addresses the use of teleprocessing and time sharing by the RAX IBM system and the possibility to introduce a dialog with the machine to develop an application in which the computer plays the role of a teacher for different pupils at the same time. Two operating modes are thus exploited: a teacher-mode and a pupil-mode. The developed CAI (computer-aided instruction) system comprises a checker to check the course syntax in teacher-mode, a translator to trans-code the course written in teacher-mode into a form which can be processes by the execution programme, and the execution programme which presents the course in pupil-mode

  19. Computer-aided system for fire fighting in an underground mine

    Energy Technology Data Exchange (ETDEWEB)

    Rosiek, F; Sikora, M; Urbanski, J [Politechnika Wroclawska (Poland). Instytut Gornictwa

    1989-01-01

    Discusses structure of an algorithm for computer-aided planning of fire fighting and rescue in an underground coal mine. The algorithm developed by the Mining Institute of the Wroclaw Technical University consists of ten options: regulations on fire fighting, fire alarm for miners working underground (rescue ways, fire zones etc.), information system for mine management, movements of fire fighting teams, distribution of fire fighting equipment, assessment of explosion hazards of fire gases, fire gas temperature control of blower operation, detection of endogenous fires, ventilation control. 2 refs.

  20. Performance of fusion algorithms for computer-aided detection and classification of mines in very shallow water obtained from testing in navy Fleet Battle Exercise-Hotel 2000

    Science.gov (United States)

    Ciany, Charles M.; Zurawski, William; Kerfoot, Ian

    2001-10-01

    The performance of Computer Aided Detection/Computer Aided Classification (CAD/CAC) Fusion algorithms on side-scan sonar images was evaluated using data taken at the Navy's's Fleet Battle Exercise-Hotel held in Panama City, Florida, in August 2000. A 2-of-3 binary fusion algorithm is shown to provide robust performance. The algorithm accepts the classification decisions and associated contact locations form three different CAD/CAC algorithms, clusters the contacts based on Euclidian distance, and then declares a valid target when a clustered contact is declared by at least 2 of the 3 individual algorithms. This simple binary fusion provided a 96 percent probability of correct classification at a false alarm rate of 0.14 false alarms per image per side. The performance represented a 3.8:1 reduction in false alarms over the best performing single CAD/CAC algorithm, with no loss in probability of correct classification.

  1. Novel Schemes for Measurement-Based Quantum Computation

    International Nuclear Information System (INIS)

    Gross, D.; Eisert, J.

    2007-01-01

    We establish a framework which allows one to construct novel schemes for measurement-based quantum computation. The technique develops tools from many-body physics--based on finitely correlated or projected entangled pair states--to go beyond the cluster-state based one-way computer. We identify resource states radically different from the cluster state, in that they exhibit nonvanishing correlations, can be prepared using nonmaximally entangling gates, or have very different local entanglement properties. In the computational models, randomness is compensated in a different manner. It is shown that there exist resource states which are locally arbitrarily close to a pure state. We comment on the possibility of tailoring computational models to specific physical systems

  2. Novel schemes for measurement-based quantum computation.

    Science.gov (United States)

    Gross, D; Eisert, J

    2007-06-01

    We establish a framework which allows one to construct novel schemes for measurement-based quantum computation. The technique develops tools from many-body physics-based on finitely correlated or projected entangled pair states-to go beyond the cluster-state based one-way computer. We identify resource states radically different from the cluster state, in that they exhibit nonvanishing correlations, can be prepared using nonmaximally entangling gates, or have very different local entanglement properties. In the computational models, randomness is compensated in a different manner. It is shown that there exist resource states which are locally arbitrarily close to a pure state. We comment on the possibility of tailoring computational models to specific physical systems.

  3. Microwave processing of a dental ceramic used in computer-aided design/computer-aided manufacturing.

    Science.gov (United States)

    Pendola, Martin; Saha, Subrata

    2015-01-01

    Because of their favorable mechanical properties and natural esthetics, ceramics are widely used in restorative dentistry. The conventional ceramic sintering process required for their use is usually slow, however, and the equipment has an elevated energy consumption. Sintering processes that use microwaves have several advantages compared to regular sintering: shorter processing times, lower energy consumption, and the capacity for volumetric heating. The objective of this study was to test the mechanical properties of a dental ceramic used in computer-aided design/computer-aided manufacturing (CAD/CAM) after the specimens were processed with microwave hybrid sintering. Density, hardness, and bending strength were measured. When ceramic specimens were sintered with microwaves, the processing times were reduced and protocols were simplified. Hardness was improved almost 20% compared to regular sintering, and flexural strength measurements suggested that specimens were approximately 50% stronger than specimens sintered in a conventional system. Microwave hybrid sintering may preserve or improve the mechanical properties of dental ceramics designed for CAD/CAM processing systems, reducing processing and waiting times.

  4. Numerical analysis of boosting scheme for scalable NMR quantum computation

    International Nuclear Information System (INIS)

    SaiToh, Akira; Kitagawa, Masahiro

    2005-01-01

    Among initialization schemes for ensemble quantum computation beginning at thermal equilibrium, the scheme proposed by Schulman and Vazirani [in Proceedings of the 31st ACM Symposium on Theory of Computing (STOC'99) (ACM Press, New York, 1999), pp. 322-329] is known for the simple quantum circuit to redistribute the biases (polarizations) of qubits and small time complexity. However, our numerical simulation shows that the number of qubits initialized by the scheme is rather smaller than expected from the von Neumann entropy because of an increase in the sum of the binary entropies of individual qubits, which indicates a growth in the total classical correlation. This result--namely, that there is such a significant growth in the total binary entropy--disagrees with that of their analysis

  5. Code-Aided Estimation and Detection on Time-Varying Correlated Mimo Channels: A Factor Graph Approach

    Directory of Open Access Journals (Sweden)

    Simoens Frederik

    2006-01-01

    Full Text Available This paper concerns channel tracking in a multiantenna context for correlated flat-fading channels obeying a Gauss-Markov model. It is known that data-aided tracking of fast-fading channels requires a lot of pilot symbols in order to achieve sufficient accuracy, and hence decreases the spectral efficiency. To overcome this problem, we design a code-aided estimation scheme which exploits information from both the pilot symbols and the unknown coded data symbols. The algorithm is derived based on a factor graph representation of the system and application of the sum-product algorithm. The sum-product algorithm reveals how soft information from the decoder should be exploited for the purpose of estimation and how the information bits can be detected. Simulation results illustrate the effectiveness of our approach.

  6. Computer-aided modeling framework for efficient model development, analysis and identification

    DEFF Research Database (Denmark)

    Heitzig, Martina; Sin, Gürkan; Sales Cruz, Mauricio

    2011-01-01

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy, and water. This trend is set to continue due to the substantial benefits computer-aided...... methods introduce. The key prerequisite of computer-aided product-process engineering is however the availability of models of different types, forms, and application modes. The development of the models required for the systems under investigation tends to be a challenging and time-consuming task....... The methodology has been implemented into a computer-aided modeling framework, which combines expert skills, tools, and database connections that are required for the different steps of the model development work-flow with the goal to increase the efficiency of the modeling process. The framework has two main...

  7. Computer-aided power systems analysis

    CERN Document Server

    Kusic, George

    2008-01-01

    Computer applications yield more insight into system behavior than is possible by using hand calculations on system elements. Computer-Aided Power Systems Analysis: Second Edition is a state-of-the-art presentation of basic principles and software for power systems in steady-state operation. Originally published in 1985, this revised edition explores power systems from the point of view of the central control facility. It covers the elements of transmission networks, bus reference frame, network fault and contingency calculations, power flow on transmission networks, generator base power setti

  8. Computer-aided polyp detection on CT colonography: Comparison of three systems in a high-risk human population

    International Nuclear Information System (INIS)

    Park, Hee Sun; Kim, Se Hyung; Kim, Jong Hyo; Lee, June-Goo; Kim, Sang Gyun; Lee, Jeong Min; Lee, Jae Young; Han, Joon Koo; Choi, Byung Ihn

    2010-01-01

    Purpose: To compare the detection performances of two commercial and one academic computer-aided diagnosis (CAD) systems for polyp detection on CT colonography (CTC) in a high-risk human population and to assess their detection characteristics. Materials and methods: This retrospective study had institutional review board approval, but informed consent was waived. Sixty-eight patients who were suspected of having colonic polyps and scheduled for colonoscopic polyp removal were included. After CTC was performed using a 64-row MDCT, two commercial (PEV, CAR) and one academic (Hessian matrix-based) CAD systems were applied to each CTC dataset. Colonoscopy using the segmental unblinded technique was performed as a standard of reference. Per-polyp and per-patient sensitivities were calculated and compared for each CAD system. The mean number of false-positives (FPs) and false-negatives (FNs) was computed and the causes of all FPs and FNs were analyzed. Results: A total of 151 polyps in 61 patients were detected (77 polyps <6 mm, 48 6-9.9 mm, 26 ≥ 10 mm). Per-polyp sensitivity for PEV, CAR, and Hessian matrix-based CAD were: 71.6%, 78.4%, and 83.8% for polyps ≥6 mm, and 88.5%, 96.2%, and 96.2% for polyps ≥10 mm. Per-patient sensitivity for polyps ≥6 mm was 80.4%, 89.1%, and 93.5%, and 87%, 95.7%, and 95.7% for polyps ≥10 mm, respectively. Per-polyp and per-patient sensitivities were not significantly different among the three CAD systems regardless of size threshold. Mean number of FPs was 6.9 for PEV, 7.3 for CAR, and 14 for Hessian matrix-based CAD. The most common cause of FPs were feces, followed by extracolonic findings, prominent folds and ileocecal valve, and rectal tube. The distribution of the causes of FPs was significantly different among the three systems. Conclusion: Sensitivity of the three CAD systems for polyp detection was comparable regardless of the polyp size threshold; however, the number of FPs was higher in the Hessian matrix-based CAD

  9. A DFIG Islanding Detection Scheme Based on Reactive Power Infusion

    Science.gov (United States)

    Wang, M.; Liu, C.; He, G. Q.; Li, G. H.; Feng, K. H.; Sun, W. W.

    2017-07-01

    A lot of research has been done on photovoltaic (the “PV”) power system islanding detection in recent years. As a comparison, much less attention has been paid to islanding in wind turbines. Meanwhile, wind turbines can work in islanding conditions for quite a long period, which can be harmful to equipments and cause safety hazards. This paper presents and examines a double fed introduction generation (the “DFIG”) islanding detection scheme based on feedback of reactive power and frequency and uses a trigger signal of reactive power infusion which can be obtained by dividing the voltage total harmonic distortion (the "THD") by the voltage THD of last cycle to avoid the deterioration of power quality. This DFIG islanding detection scheme uses feedback of reactive power current loop to amplify the frequency differences in islanding and normal conditions. Simulation results show that the DFIG islanding detection scheme is effective.

  10. Computer-aided modeling for efficient and innovative product-process engineering

    DEFF Research Database (Denmark)

    Heitzig, Martina

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy and water. This trend is set to continue due to the substantial benefits computer...... in chemical and biochemical engineering have been solved to illustrate the application of the generic modelling methodology, the computeraided modelling framework and the developed software tool.......-aided methods provide. The key prerequisite of computer-aided productprocess engineering is however the availability of models of different types, forms and application modes. The development of the models required for the systems under investigation tends to be a challenging, time-consuming and therefore cost...

  11. Computer-Aided Corrosion Program Management

    Science.gov (United States)

    MacDowell, Louis

    2010-01-01

    This viewgraph presentation reviews Computer-Aided Corrosion Program Management at John F. Kennedy Space Center. The contents include: 1) Corrosion at the Kennedy Space Center (KSC); 2) Requirements and Objectives; 3) Program Description, Background and History; 4) Approach and Implementation; 5) Challenges; 6) Lessons Learned; 7) Successes and Benefits; and 8) Summary and Conclusions.

  12. Computer-aided voice training in higher education: participants ...

    African Journals Online (AJOL)

    The training of performance singing in a multi lingual, multi cultural educational context presents unique problems and requires inventive teaching strategies. Computer-aided training offers objective visual feedback of the voice production that can be implemented as a teaching aid in higher education. This article reports on ...

  13. Possible Computer Vision Systems and Automated or Computer-Aided Edging and Trimming

    Science.gov (United States)

    Philip A. Araman

    1990-01-01

    This paper discusses research which is underway to help our industry reduce costs, increase product volume and value recovery, and market more accurately graded and described products. The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or computer controlled processing. This paper...

  14. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  15. Intelligent Aggregation Based on Content Routing Scheme for Cloud Computing

    Directory of Open Access Journals (Sweden)

    Jiachen Xu

    2017-10-01

    Full Text Available Cloud computing has emerged as today’s most exciting computing paradigm for providing services using a shared framework, which opens a new door for solving the problems of the explosive growth of digital resource demands and their corresponding convenience. With the exponential growth of the number of data types and data size in so-called big data work, the backbone network is under great pressure due to its transmission capacity, which is lower than the growth of the data size and would seriously hinder the development of the network without an effective approach to solve this problem. In this paper, an Intelligent Aggregation based on a Content Routing (IACR scheme for cloud computing, which could reduce the amount of data in the network effectively and play a basic supporting role in the development of cloud computing, is first put forward. All in all, the main innovations in this paper are: (1 A framework for intelligent aggregation based on content routing is proposed, which can support aggregation based content routing; (2 The proposed IACR scheme could effectively route the high aggregation ratio data to the data center through the same routing path so as to effectively reduce the amount of data that the network transmits. The theoretical analyses experiments and results show that, compared with the previous original routing scheme, the IACR scheme can balance the load of the whole network, reduce the amount of data transmitted in the network by 41.8%, and reduce the transmission time by 31.6% in the same network with a more balanced network load.

  16. Computational modelling of the impact of AIDS on business.

    Science.gov (United States)

    Matthews, Alan P

    2007-07-01

    An overview of computational modelling of the impact of AIDS on business in South Africa, with a detailed description of the AIDS Projection Model (APM) for companies, developed by the author, and suggestions for further work. Computational modelling of the impact of AIDS on business in South Africa requires modelling of the epidemic as a whole, and of its impact on a company. This paper gives an overview of epidemiological modelling, with an introduction to the Actuarial Society of South Africa (ASSA) model, the most widely used such model for South Africa. The APM produces projections of HIV prevalence, new infections, and AIDS mortality on a company, based on the anonymous HIV testing of company employees, and projections from the ASSA model. A smoothed statistical model of the prevalence test data is computed, and then the ASSA model projection for each category of employees is adjusted so that it matches the measured prevalence in the year of testing. FURTHER WORK: Further techniques that could be developed are microsimulation (representing individuals in the computer), scenario planning for testing strategies, and models for the business environment, such as models of entire sectors, and mapping of HIV prevalence in time and space, based on workplace and community data.

  17. Single reading with computer-aided detection performed by selected radiologists in a breast cancer screening program

    Energy Technology Data Exchange (ETDEWEB)

    Bargalló, Xavier, E-mail: xbarga@clinic.cat [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Santamaría, Gorane; Amo, Montse del; Arguis, Pedro [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Ríos, José [Biostatistics and Data Management Core Facility, IDIBAPS, (Hospital Clinic) C/ Mallorca, 183. Floor -1. Office #60. 08036 Barcelona (Spain); Grau, Jaume [Preventive Medicine and Epidemiology Unit, Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Burrel, Marta; Cores, Enrique; Velasco, Martín [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain)

    2014-11-15

    Highlights: • 1-The cancer detection rate of the screening program improved using a single reading protocol by experienced radiologists assisted by CAD. • 2-The cancer detection rate improved at the cost of increasing recall rate. • 3-CAD, used by breast radiologists, did not help to detect more cancers. - Abstract: Objectives: To assess the impact of shifting from a standard double reading plus arbitration protocol to a single reading by experienced radiologists assisted by computer-aided detection (CAD) in a breast cancer screening program. Methods: This was a prospective study approved by the ethics committee. Data from 21,321 consecutive screening mammograms in incident rounds (2010–2012) were read following a single reading plus CAD protocol and compared with data from 47,462 consecutive screening mammograms in incident rounds (2004–2010) that were interpreted following a double reading plus arbitration protocol. For the single reading, radiologists were selected on the basis of the appraisement of their previous performance. Results: Period 2010–2012 vs. period 2004–2010: Cancer detection rate (CDR): 6.1‰ (95% confidence interval: 5.1–7.2) vs. 5.25‰; Recall rate (RR): 7.02% (95% confidence interval: 6.7–7.4) vs. 7.24% (selected readers before arbitration) and vs. 3.94 (all readers after arbitration); Predictive positive value of recall: 8.69% vs. 13.32%. Average size of invasive cancers: 14.6 ± 9.5 mm vs. 14.3 ± 9.5 mm. Stage: 0 (22.3/26.1%); I (59.2/50.8%); II (19.2/17.1%); III (3.1/3.3%); IV (0/1.9%). Specialized breast radiologists performed better than general radiologists. Conclusions: The cancer detection rate of the screening program improved using a single reading protocol by experienced radiologists assisted by CAD, at the cost of a moderate increase of the recall rate mainly related to the lack of arbitration.

  18. Low Cost Skin Segmentation Scheme in Videos Using Two Alternative Methods for Dynamic Hand Gesture Detection Method

    Directory of Open Access Journals (Sweden)

    Eman Thabet

    2017-01-01

    Full Text Available Recent years have witnessed renewed interest in developing skin segmentation approaches. Skin feature segmentation has been widely employed in different aspects of computer vision applications including face detection and hand gestures recognition systems. This is mostly due to the attractive characteristics of skin colour and its effectiveness to object segmentation. On the contrary, there are certain challenges in using human skin colour as a feature to segment dynamic hand gesture, due to various illumination conditions, complicated environment, and computation time or real-time method. These challenges have led to the insufficiency of many of the skin color segmentation approaches. Therefore, to produce simple, effective, and cost efficient skin segmentation, this paper has proposed a skin segmentation scheme. This scheme includes two procedures for calculating generic threshold ranges in Cb-Cr colour space. The first procedure uses threshold values trained online from nose pixels of the face region. Meanwhile, the second procedure known as the offline training procedure uses thresholds trained out of skin samples and weighted equation. The experimental results showed that the proposed scheme achieved good performance in terms of efficiency and computation time.

  19. Implementation of a computer-aided detection tool for quantification of intracranial radiologic markers on brain CT images

    Science.gov (United States)

    Aghaei, Faranak; Ross, Stephen R.; Wang, Yunzhi; Wu, Dee H.; Cornwell, Benjamin O.; Ray, Bappaditya; Zheng, Bin

    2017-03-01

    Aneurysmal subarachnoid hemorrhage (aSAH) is a form of hemorrhagic stroke that affects middle-aged individuals and associated with significant morbidity and/or mortality especially those presenting with higher clinical and radiologic grades at the time of admission. Previous studies suggested that blood extravasated after aneurysmal rupture was a potentially clinical prognosis factor. But all such studies used qualitative scales to predict prognosis. The purpose of this study is to develop and test a new interactive computer-aided detection (CAD) tool to detect, segment and quantify brain hemorrhage and ventricular cerebrospinal fluid on non-contrasted brain CT images. First, CAD segments brain skull using a multilayer region growing algorithm with adaptively adjusted thresholds. Second, CAD assigns pixels inside the segmented brain region into one of three classes namely, normal brain tissue, blood and fluid. Third, to avoid "black-box" approach and increase accuracy in quantification of these two image markers using CT images with large noise variation in different cases, a graphic User Interface (GUI) was implemented and allows users to visually examine segmentation results. If a user likes to correct any errors (i.e., deleting clinically irrelevant blood or fluid regions, or fill in the holes inside the relevant blood or fluid regions), he/she can manually define the region and select a corresponding correction function. CAD will automatically perform correction and update the computed data. The new CAD tool is now being used in clinical and research settings to estimate various quantitatively radiological parameters/markers to determine radiological severity of aSAH at presentation and correlate the estimations with various homeostatic/metabolic derangements and predict clinical outcome.

  20. Enhancing Community Detection By Affinity-based Edge Weighting Scheme

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Andy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sanders, Geoffrey [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Henson, Van [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Vassilevski, Panayot [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-10-05

    Community detection refers to an important graph analytics problem of finding a set of densely-connected subgraphs in a graph and has gained a great deal of interest recently. The performance of current community detection algorithms is limited by an inherent constraint of unweighted graphs that offer very little information on their internal community structures. In this paper, we propose a new scheme to address this issue that weights the edges in a given graph based on recently proposed vertex affinity. The vertex affinity quantifies the proximity between two vertices in terms of their clustering strength, and therefore, it is ideal for graph analytics applications such as community detection. We also demonstrate that the affinity-based edge weighting scheme can improve the performance of community detection algorithms significantly.

  1. Vascular tissue engineering by computer-aided laser micromachining.

    Science.gov (United States)

    Doraiswamy, Anand; Narayan, Roger J

    2010-04-28

    Many conventional technologies for fabricating tissue engineering scaffolds are not suitable for fabricating scaffolds with patient-specific attributes. For example, many conventional technologies for fabricating tissue engineering scaffolds do not provide control over overall scaffold geometry or over cell position within the scaffold. In this study, the use of computer-aided laser micromachining to create scaffolds for vascular tissue networks was investigated. Computer-aided laser micromachining was used to construct patterned surfaces in agarose or in silicon, which were used for differential adherence and growth of cells into vascular tissue networks. Concentric three-ring structures were fabricated on agarose hydrogel substrates, in which the inner ring contained human aortic endothelial cells, the middle ring contained HA587 human elastin and the outer ring contained human aortic vascular smooth muscle cells. Basement membrane matrix containing vascular endothelial growth factor and heparin was to promote proliferation of human aortic endothelial cells within the vascular tissue networks. Computer-aided laser micromachining provides a unique approach to fabricate small-diameter blood vessels for bypass surgery as well as other artificial tissues with complex geometries.

  2. Development and clinical application of a computer-aided real-time feedback system for detecting in-bed physical activities.

    Science.gov (United States)

    Lu, Liang-Hsuan; Chiang, Shang-Lin; Wei, Shun-Hwa; Lin, Chueh-Ho; Sung, Wen-Hsu

    2017-08-01

    Being bedridden long-term can cause deterioration in patients' physiological function and performance, limiting daily activities and increasing the incidence of falls and other accidental injuries. Little research has been carried out in designing effective detecting systems to monitor the posture and status of bedridden patients and to provide accurate real-time feedback on posture. The purposes of this research were to develop a computer-aided system for real-time detection of physical activities in bed and to validate the system's validity and test-retest reliability in determining eight postures: motion leftward/rightward, turning over leftward/rightward, getting up leftward/rightward, and getting off the bed leftward/rightward. The in-bed physical activity detecting system consists mainly of a clinical sickbed, signal amplifier, a data acquisition (DAQ) system, and operating software for computing and determining postural changes associated with four load cell sensing components. Thirty healthy subjects (15 males and 15 females, mean age = 27.8 ± 5.3 years) participated in the study. All subjects were asked to execute eight in-bed activities in a random order and to participate in an evaluation of the test-retest reliability of the results 14 days later. Spearman's rank correlation coefficient was used to compare the system's determinations of postural states with researchers' recordings of postural changes. The test-retest reliability of the system's ability to determine postures was analyzed using the interclass correlation coefficient ICC(3,1). The system was found to exhibit high validity and accuracy (r = 0.928, p system was particularly accurate in detecting motion rightward (90%), turning over leftward (83%), sitting up leftward or rightward (87-93%), and getting off the bed (100%). The test-retest reliability ICC(3,1) value was 0.968 (p system developed in this study exhibits satisfactory validity and reliability in detecting changes in

  3. Cloud-Based NoSQL Open Database of Pulmonary Nodules for Computer-Aided Lung Cancer Diagnosis and Reproducible Research.

    Science.gov (United States)

    Ferreira Junior, José Raniery; Oliveira, Marcelo Costa; de Azevedo-Marques, Paulo Mazzoncini

    2016-12-01

    Lung cancer is the leading cause of cancer-related deaths in the world, and its main manifestation is pulmonary nodules. Detection and classification of pulmonary nodules are challenging tasks that must be done by qualified specialists, but image interpretation errors make those tasks difficult. In order to aid radiologists on those hard tasks, it is important to integrate the computer-based tools with the lesion detection, pathology diagnosis, and image interpretation processes. However, computer-aided diagnosis research faces the problem of not having enough shared medical reference data for the development, testing, and evaluation of computational methods for diagnosis. In order to minimize this problem, this paper presents a public nonrelational document-oriented cloud-based database of pulmonary nodules characterized by 3D texture attributes, identified by experienced radiologists and classified in nine different subjective characteristics by the same specialists. Our goal with the development of this database is to improve computer-aided lung cancer diagnosis and pulmonary nodule detection and classification research through the deployment of this database in a cloud Database as a Service framework. Pulmonary nodule data was provided by the Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI), image descriptors were acquired by a volumetric texture analysis, and database schema was developed using a document-oriented Not only Structured Query Language (NoSQL) approach. The proposed database is now with 379 exams, 838 nodules, and 8237 images, 4029 of them are CT scans and 4208 manually segmented nodules, and it is allocated in a MongoDB instance on a cloud infrastructure.

  4. TE/TM scheme for computation of electromagnetic fields in accelerators

    International Nuclear Information System (INIS)

    Zagorodnov, Igor; Weiland, Thomas

    2005-01-01

    We propose a new two-level economical conservative scheme for short-range wake field calculation in three dimensions. The scheme does not have dispersion in the longitudinal direction and is staircase free (second order convergent). Unlike the finite-difference time domain method (FDTD), it is based on a TE/TM like splitting of the field components in time. Additionally, it uses an enhanced alternating direction splitting of the transverse space operator that makes the scheme computationally as effective as the conventional FDTD method. Unlike the FDTD ADI and low-order Strang methods, the splitting error in our scheme is only of fourth order. As numerical examples show, the new scheme is much more accurate on the long-time scale than the conventional FDTD approach

  5. Computer aided safety analysis 1989

    International Nuclear Information System (INIS)

    1990-04-01

    The meeting was conducted in a workshop style, to encourage involvement of all participants during the discussions. Forty-five (45) experts from 19 countries, plus 22 experts from the GDR participated in the meeting. A list of participants can be found at the end of this volume. Forty-two (42) papers were presented and discussed during the meeting. Additionally an open discussion was held on the possible directions of the IAEA programme on Computer Aided Safety Analysis. A summary of the conclusions of these discussions is presented in the publication. The remainder of this proceedings volume comprises the transcript of selected technical papers (22) presented in the meeting. It is the intention of the IAEA that the publication of these proceedings will extend the benefits of the discussions held during the meeting to a larger audience throughout the world. The Technical Committee/Workshop on Computer Aided Safety Analysis was organized by the IAEA in cooperation with the National Board for Safety and Radiological Protection (SAAS) of the German Democratic Republic in Berlin. The purpose of the meeting was to provide an opportunity for discussions on experiences in the use of computer codes used for safety analysis of nuclear power plants. In particular it was intended to provide a forum for exchange of information among experts using computer codes for safety analysis under the Technical Cooperation Programme on Safety of WWER Type Reactors (RER/9/004) and other experts throughout the world. A separate abstract was prepared for each of the 22 selected papers. Refs, figs tabs and pictures

  6. Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Aghaei, Faranak; Tan, Maxine; Liu, Hong; Zheng, Bin; Hollingsworth, Alan B.; Qian, Wei

    2015-01-01

    Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy

  7. Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Aghaei, Faranak; Tan, Maxine; Liu, Hong; Zheng, Bin, E-mail: Bin.Zheng-1@ou.edu [School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States); Hollingsworth, Alan B. [Mercy Women’s Center, Mercy Health Center, Oklahoma City, Oklahoma 73120 (United States); Qian, Wei [Department of Electrical and Computer Engineering, University of Texas, El Paso, Texas 79968 (United States)

    2015-11-15

    Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy.

  8. [The automatic iris map overlap technology in computer-aided iridiagnosis].

    Science.gov (United States)

    He, Jia-feng; Ye, Hu-nian; Ye, Miao-yuan

    2002-11-01

    In the paper, iridology and computer-aided iridiagnosis technologies are briefly introduced and the extraction method of the collarette contour is then investigated. The iris map can be overlapped on the original iris image based on collarette contour extraction. The research on collarette contour extraction and iris map overlap is of great importance to computer-aided iridiagnosis technologies.

  9. A supervisor system for computer aided laser machining

    International Nuclear Information System (INIS)

    Mukherjee, J.K.

    1990-01-01

    Lasers achieve non divergent beam of short wavelength energy which can propagate through normal atmosphere with little divergence and can be focused on very fine points. The final high energy per unit area on target is highly localised and suitable for various types of machining at high speeds. The most notable factor is that this high energy spot can be located precisely using light-weight optical components. The laser-machining is very amenable to environmental conditions unlike electron beam and other techniques. Precision cutting and welding of nuclear materials in normal or non oxidising atmosphere can be done using this fairly easily. To achieve these objectives, development of a computer controlled laser machining system has been undertaken. The development project aims at building a computer aided machine with indegenous controller and medium power laser suitable for cutting, welding, and marking. This paper describes the integration of the various computer aided functions, spanning over the full range, from job-defining to final finished part-delivary, in computer aided laser machining. Various innovative features of the system that render it suitable for laser tool development as well as for special machining applications with user-friendliness have been covered. (author). 5 refs., 5 figs

  10. Computer-aided system design

    Science.gov (United States)

    Walker, Carrie K.

    1991-01-01

    A technique has been developed for combining features of a systems architecture design and assessment tool and a software development tool. This technique reduces simulation development time and expands simulation detail. The Architecture Design and Assessment System (ADAS), developed at the Research Triangle Institute, is a set of computer-assisted engineering tools for the design and analysis of computer systems. The ADAS system is based on directed graph concepts and supports the synthesis and analysis of software algorithms mapped to candidate hardware implementations. Greater simulation detail is provided by the ADAS functional simulator. With the functional simulator, programs written in either Ada or C can be used to provide a detailed description of graph nodes. A Computer-Aided Software Engineering tool developed at the Charles Stark Draper Laboratory (CSDL CASE) automatically generates Ada or C code from engineering block diagram specifications designed with an interactive graphical interface. A technique to use the tools together has been developed, which further automates the design process.

  11. Enabling an Integrated Rate-temporal Learning Scheme on Memristor

    Science.gov (United States)

    He, Wei; Huang, Kejie; Ning, Ning; Ramanathan, Kiruthika; Li, Guoqi; Jiang, Yu; Sze, Jiayin; Shi, Luping; Zhao, Rong; Pei, Jing

    2014-04-01

    Learning scheme is the key to the utilization of spike-based computation and the emulation of neural/synaptic behaviors toward realization of cognition. The biological observations reveal an integrated spike time- and spike rate-dependent plasticity as a function of presynaptic firing frequency. However, this integrated rate-temporal learning scheme has not been realized on any nano devices. In this paper, such scheme is successfully demonstrated on a memristor. Great robustness against the spiking rate fluctuation is achieved by waveform engineering with the aid of good analog properties exhibited by the iron oxide-based memristor. The spike-time-dependence plasticity (STDP) occurs at moderate presynaptic firing frequencies and spike-rate-dependence plasticity (SRDP) dominates other regions. This demonstration provides a novel approach in neural coding implementation, which facilitates the development of bio-inspired computing systems.

  12. Computer-aided diagnosis of early knee osteoarthritis based on MRI T2 mapping.

    Science.gov (United States)

    Wu, Yixiao; Yang, Ran; Jia, Sen; Li, Zhanjun; Zhou, Zhiyang; Lou, Ting

    2014-01-01

    This work was aimed at studying the method of computer-aided diagnosis of early knee OA (OA: osteoarthritis). Based on the technique of MRI (MRI: Magnetic Resonance Imaging) T2 Mapping, through computer image processing, feature extraction, calculation and analysis via constructing a classifier, an effective computer-aided diagnosis method for knee OA was created to assist doctors in their accurate, timely and convenient detection of potential risk of OA. In order to evaluate this method, a total of 1380 data from the MRI images of 46 samples of knee joints were collected. These data were then modeled through linear regression on an offline general platform by the use of the ImageJ software, and a map of the physical parameter T2 was reconstructed. After the image processing, the T2 values of ten regions in the WORMS (WORMS: Whole-organ Magnetic Resonance Imaging Score) areas of the articular cartilage were extracted to be used as the eigenvalues in data mining. Then,a RBF (RBF: Radical Basis Function) network classifier was built to classify and identify the collected data. The classifier exhibited a final identification accuracy of 75%, indicating a good result of assisting diagnosis. Since the knee OA classifier constituted by a weights-directly-determined RBF neural network didn't require any iteration, our results demonstrated that the optimal weights, appropriate center and variance could be yielded through simple procedures. Furthermore, the accuracy for both the training samples and the testing samples from the normal group could reach 100%. Finally, the classifier was superior both in time efficiency and classification performance to the frequently used classifiers based on iterative learning. Thus it was suitable to be used as an aid to computer-aided diagnosis of early knee OA.

  13. Towards a security model for computational puzzle schemes

    NARCIS (Netherlands)

    Tang, Qiang; Jeckmans, Arjan

    2011-01-01

    In the literature, computational puzzle schemes have been considered as a useful tool for a number of applications, such as constructing timed cryptography, fighting junk emails, and protecting critical infrastructure from denial-of-service attacks. However, there is a lack of a general security

  14. A study on computer-aided diagnosis based on temporal subtraction of sequential chest radiographs (in Japanese)

    International Nuclear Information System (INIS)

    Kano, Akiko

    2001-01-01

    An automated digital image subtraction technique for use with pairs of temporally sequential chest radiographs has been developed to aid radiologists in the detection of interval changes. Automated image registration based on nonlinear geometric warping is performed prior to subtraction in order to deal with complicated radiographic misregistration. Processing includes global matching, to achieve rough registration between the entire lung fields in the two images, and local matching, based on a cross-correlation method, to determine local shift values for a number of small regions. A proper warping of x,y-coordinates is determined by fitting two-dimensional polynomials to the distributions of the shift values. One image is warped and then subtracted from the other. The resultant subtraction images were able to enhance the conspicuity of various types of interval changes. Improved global matching based on a weighted template matching method achieved robust registration even with photofluorographs taken in chest mass screening programs, which had previously presented us with a relatively large number of poor-registration images. The new method was applied to 129 pairs of chest mass screening images, and offered registration accuracy as good as manual global matching. An observer test using 114 cases including 57 lung cancer cases presented better sensitivity and specificity on average compared to conventional comparison readings. In addition, newly developed image processing that eliminates the rib edge artifacts in subtraction images was applied to 26 images having pathological interval changes; results showed the potential for application to automated schemes for the detection of interval change patterns. With its capacity to improve the diagnostic accuracy of chest radiographs, the chest temporal subtraction technique promises to become an important element of computer-aided diagnosis (CAD) systems

  15. Application of computer-aided multi-scale modelling framework – Aerosol case study

    DEFF Research Database (Denmark)

    Heitzig, Martina; Sin, Gürkan; Glarborg, Peter

    2011-01-01

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy and water. This trend is set to continue due to the substantial benefits computer-aided...... methods provide. The key prerequisite of computer-aided product-process engineering is however the availability of models of different types, forms and application modes. The development of the models required for the systems under investigation tends to be a challenging and time-consuming task involving...... numerous steps, expert skills and different modelling tools. This motivates the development of a computer-aided modelling framework that supports the user during model development, documentation, analysis, identification, application and re-use with the goal to increase the efficiency of the modelling...

  16. Development of Fault Detection and Diagnosis Schemes for Industrial Refrigeration Systems

    DEFF Research Database (Denmark)

    Thybo, C.; Izadi-Zamanabadi, Roozbeh

    2004-01-01

    The success of a fault detection and diagnosis (FDD) scheme depends not alone on developing an advanced detection scheme. To enable successful deployment in industrial applications, an economically optimal development of FDD schemes are required. This paper reviews and discusses the gained...... experiences achieved by employing a combination of various techniques, methods, and algorithms, which are proposed by academia, on an industrial application. The main focus is on sharing the "lessons learned" from developing and employing Faulttolerant functionalities to a controlled process in order to meet...... the industrial needs while satisfying economically motivated constraints....

  17. Secure Dynamic access control scheme of PHR in cloud computing.

    Science.gov (United States)

    Chen, Tzer-Shyong; Liu, Chia-Hui; Chen, Tzer-Long; Chen, Chin-Sheng; Bau, Jian-Guo; Lin, Tzu-Ching

    2012-12-01

    With the development of information technology and medical technology, medical information has been developed from traditional paper records into electronic medical records, which have now been widely applied. The new-style medical information exchange system "personal health records (PHR)" is gradually developed. PHR is a kind of health records maintained and recorded by individuals. An ideal personal health record could integrate personal medical information from different sources and provide complete and correct personal health and medical summary through the Internet or portable media under the requirements of security and privacy. A lot of personal health records are being utilized. The patient-centered PHR information exchange system allows the public autonomously maintain and manage personal health records. Such management is convenient for storing, accessing, and sharing personal medical records. With the emergence of Cloud computing, PHR service has been transferred to storing data into Cloud servers that the resources could be flexibly utilized and the operation cost can be reduced. Nevertheless, patients would face privacy problem when storing PHR data into Cloud. Besides, it requires a secure protection scheme to encrypt the medical records of each patient for storing PHR into Cloud server. In the encryption process, it would be a challenge to achieve accurately accessing to medical records and corresponding to flexibility and efficiency. A new PHR access control scheme under Cloud computing environments is proposed in this study. With Lagrange interpolation polynomial to establish a secure and effective PHR information access scheme, it allows to accurately access to PHR with security and is suitable for enormous multi-users. Moreover, this scheme also dynamically supports multi-users in Cloud computing environments with personal privacy and offers legal authorities to access to PHR. From security and effectiveness analyses, the proposed PHR access

  18. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv

    Energy Technology Data Exchange (ETDEWEB)

    Messerli, Michael, E-mail: Michael.Messerli@usz.ch [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Kluckert, Thomas; Knitel, Meinhard [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Rengier, Fabian [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg (Germany); Warschkow, René [Department of Surgery, Cantonal Hospital St. Gallen (Switzerland); Alkadhi, Hatem [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich (Switzerland); Leschka, Sebastian [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich (Switzerland); Wildermuth, Simon; Bauer, Ralf W. [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland)

    2016-12-15

    Highlights: • Computer-aided detection (CAD) of solid pulmonary nodules was compared in 202 patients in standard dose and ultralow dose CT. • The per–nodule sensitivity of CAD was 70% in standard dose CT and 68% in ultralow dose CT. • The per–nodule sensitivity of CAD in standard dose CT was similar to ultralow dose CT in all size subgroups (all p > 0.05). • Adding CAD markings in ultralow dose CT significantly improved the sensitivity of two radiologists from 77% to 88% and from 66% to 79%, respectively. • CAD can serve as an excellent second reader for nodule detection in CT even at dose levels similar to chest X-ray. - Abstract: Objectives: To determine the value of computer-aided detection (CAD) for solid pulmonary nodules in ultralow radiation dose single-energy computed tomography (CT) of the chest using third-generation dual-source CT at 100 kV and fixed tube current at 70 mAs with tin filtration. Methods: 202 consecutive patients undergoing clinically indicated standard dose chest CT (1.8 ± 0.7 mSv) were prospectively included and scanned with an additional ultralow dose CT (0.13 ± 0.01 mSv) in the same session. Standard of reference (SOR) was established by consensus reading of standard dose CT by two radiologists. CAD was performed in standard dose and ultralow dose CT with two different reconstruction kernels. CAD detection rate of nodules was evaluated including subgroups of different nodule sizes (<5, 5–7, >7 mm). Sensitivity was further analysed in multivariable mixed effects logistic regression. Results: The SOR included 279 solid nodules (mean diameter 4.3 ± 3.4 mm, range 1–24 mm). There was no significant difference in per–nodule sensitivity of CAD in standard dose with 70% compared to 68% in ultralow dose CT both overall and in different size subgroups (all p > 0.05). CAD led to a significant increase of sensitivity for both radiologists reading the ultralow dose CT scans (all p < 0.001). In multivariable analysis, the use

  19. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv

    International Nuclear Information System (INIS)

    Messerli, Michael; Kluckert, Thomas; Knitel, Meinhard; Rengier, Fabian; Warschkow, René; Alkadhi, Hatem; Leschka, Sebastian; Wildermuth, Simon; Bauer, Ralf W.

    2016-01-01

    Highlights: • Computer-aided detection (CAD) of solid pulmonary nodules was compared in 202 patients in standard dose and ultralow dose CT. • The per–nodule sensitivity of CAD was 70% in standard dose CT and 68% in ultralow dose CT. • The per–nodule sensitivity of CAD in standard dose CT was similar to ultralow dose CT in all size subgroups (all p > 0.05). • Adding CAD markings in ultralow dose CT significantly improved the sensitivity of two radiologists from 77% to 88% and from 66% to 79%, respectively. • CAD can serve as an excellent second reader for nodule detection in CT even at dose levels similar to chest X-ray. - Abstract: Objectives: To determine the value of computer-aided detection (CAD) for solid pulmonary nodules in ultralow radiation dose single-energy computed tomography (CT) of the chest using third-generation dual-source CT at 100 kV and fixed tube current at 70 mAs with tin filtration. Methods: 202 consecutive patients undergoing clinically indicated standard dose chest CT (1.8 ± 0.7 mSv) were prospectively included and scanned with an additional ultralow dose CT (0.13 ± 0.01 mSv) in the same session. Standard of reference (SOR) was established by consensus reading of standard dose CT by two radiologists. CAD was performed in standard dose and ultralow dose CT with two different reconstruction kernels. CAD detection rate of nodules was evaluated including subgroups of different nodule sizes (<5, 5–7, >7 mm). Sensitivity was further analysed in multivariable mixed effects logistic regression. Results: The SOR included 279 solid nodules (mean diameter 4.3 ± 3.4 mm, range 1–24 mm). There was no significant difference in per–nodule sensitivity of CAD in standard dose with 70% compared to 68% in ultralow dose CT both overall and in different size subgroups (all p > 0.05). CAD led to a significant increase of sensitivity for both radiologists reading the ultralow dose CT scans (all p < 0.001). In multivariable analysis, the use

  20. Computer-aided Framework for Design of Pure, Mixed and Blended Products

    DEFF Research Database (Denmark)

    Cignitti, Stefano; Zhang, Lei; Gani, Rafiqul

    2015-01-01

    This paper presents a framework for computer-aided design of pure, mixed and blended chemical based products. The framework is a systematic approach to convert a Computer-aided Molecular, Mixture and Blend Design (CAMbD) formulation, based on needs and target properties, into a mixed integer non...

  1. Computer aided architectural design : futures 2001

    NARCIS (Netherlands)

    Vries, de B.; Leeuwen, van J.P.; Achten, H.H.

    2001-01-01

    CAAD Futures is a bi-annual conference that aims to promote the advancement of computer-aided architectural design in the service of those concerned with the quality of the built environment. The conferences are organized under the auspices of the CAAD Futures Foundation, which has its secretariat

  2. Students' perceptions of a multimedia computer-aided instruction ...

    African Journals Online (AJOL)

    Objective. To develop an interactive muttimedia-based computer-aided instruction (CAI) programme, to detennine its educational worth and efficacy in a multicuttural academic environment and to evaluate its usage by students with differing levels of computer literacy. Design. A prospective descriptive study evaluating ...

  3. Parallel computation of fluid-structural interactions using high resolution upwind schemes

    Science.gov (United States)

    Hu, Zongjun

    An efficient and accurate solver is developed to simulate the non-linear fluid-structural interactions in turbomachinery flutter flows. A new low diffusion E-CUSP scheme, Zha CUSP scheme, is developed to improve the efficiency and accuracy of the inviscid flux computation. The 3D unsteady Navier-Stokes equations with the Baldwin-Lomax turbulence model are solved using the finite volume method with the dual-time stepping scheme. The linearized equations are solved with Gauss-Seidel line iterations. The parallel computation is implemented using MPI protocol. The solver is validated with 2D cases for its turbulence modeling, parallel computation and unsteady calculation. The Zha CUSP scheme is validated with 2D cases, including a supersonic flat plate boundary layer, a transonic converging-diverging nozzle and a transonic inlet diffuser. The Zha CUSP2 scheme is tested with 3D cases, including a circular-to-rectangular nozzle, a subsonic compressor cascade and a transonic channel. The Zha CUSP schemes are proved to be accurate, robust and efficient in these tests. The steady and unsteady separation flows in a 3D stationary cascade under high incidence and three inlet Mach numbers are calculated to study the steady state separation flow patterns and their unsteady oscillation characteristics. The leading edge vortex shedding is the mechanism behind the unsteady characteristics of the high incidence separated flows. The separation flow characteristics is affected by the inlet Mach number. The blade aeroelasticity of a linear cascade with forced oscillating blades is studied using parallel computation. A simplified two-passage cascade with periodic boundary condition is first calculated under a medium frequency and a low incidence. The full scale cascade with 9 blades and two end walls is then studied more extensively under three oscillation frequencies and two incidence angles. The end wall influence and the blade stability are studied and compared under different

  4. Computer-aided head film analysis: the University of California San Francisco method.

    Science.gov (United States)

    Baumrind, S; Miller, D M

    1980-07-01

    Computer technology is already assuming an important role in the management of orthodontic practices. The next 10 years are likely to see expansion in computer usage into the areas of diagnosis, treatment planning, and treatment-record keeping. In the areas of diagnosis and treatment planning, one of the first problems to be attacked will be the automation of head film analysis. The problems of constructing computer-aided systems for this purpose are considered herein in the light of the authors' 10 years of experience in developing a similar system for research purposes. The need for building in methods for automatic detection and correction of gross errors is discussed and the authors' method for doing so is presented. The construction of a rudimentary machine-readable data base for research and clinical purposes is described.

  5. Computer-aided diagnosis scheme for histological classification of clustered microcalcifications on magnification mammograms

    International Nuclear Information System (INIS)

    Nakayama, Ryohei; Uchiyama, Yoshikazu; Watanabe, Ryoji; Katsuragawa, Shigehiko; Namba, Kiyoshi; Doi, Kunio

    2004-01-01

    The histological classification of clustered microcalcifications on mammograms can be difficult, and thus often require biopsy or follow-up. Our purpose in this study was to develop a computer-aided diagnosis schemefor identifying the histological classification of clustered microcalcifications on magnification mammograms in order to assist the radiologists' interpretation as a 'second opinion'. Our database consisted of 58 magnification mammograms, which included 35 malignant clustered microcalcifications (9 invasive carcinomas, 12 noninvasive carcinomas of the comedo type, and 14 noninvasive carcinomas of the noncomedo type) and 23 benign clustered microcalcifications (17 mastopathies and 6 fibroadenomas). The histological classifications of all clustered microcalcifications were proved by pathologic diagnosis. The clustered microcalcifications were first segmented by use of a novel filter bank and a thresholding technique. Five objective features on clustered microcalcifications were determined by taking into account subjective features that experienced the radiologists commonly use to identify possible histological classifications. The Bayes decision rule with five objective features was employed for distinguishing between five histological classifications. The classification accuracies for distinguishing between three malignant histological classifications were 77.8% (7/9) for invasive carcinoma, 75.0% (9/12) for noninvasive carcinoma of the comedo type, and 92.9% (13/14) for noninvasive carcinoma of the noncomedo type. The classification accuracies for distinguishing between two benign histological classifications were 94.1% (16/17) for mastopathy, and 100.0% (6/6) for fibroadenoma. This computerized method would be useful in assisting radiologists in their assessments of clustered microcalcifications

  6. A stable computational scheme for stiff time-dependent constitutive equations

    International Nuclear Information System (INIS)

    Shih, C.F.; Delorenzi, H.G.; Miller, A.K.

    1977-01-01

    Viscoplasticity and creep type constitutive equations are increasingly being employed in finite element codes for evaluating the deformation of high temperature structural members. These constitutive equations frequently exhibit stiff regimes which makes an analytical assessment of the structure very costly. A computational scheme for handling deformation in stiff regimes is proposed in this paper. By the finite element discretization, the governing partial differential equations in the spatial (x) and time (t) variables are reduced to a system of nonlinear ordinary differential equations in the independent variable t. The constitutive equations are expanded in a Taylor's series about selected values of t. The resulting system of differential equations are then integrated by an implicit scheme which employs a predictor technique to initiate the Newton-Raphson procedure. To examine the stability and accuracy of the computational scheme, a series of calculations were carried out for uniaxial specimens and thick wall tubes subjected to mechanical and thermal loading. (Auth.)

  7. SWEETLEAD: an in silico database of approved drugs, regulated chemicals, and herbal isolates for computer-aided drug discovery.

    Directory of Open Access Journals (Sweden)

    Paul A Novick

    Full Text Available In the face of drastically rising drug discovery costs, strategies promising to reduce development timelines and expenditures are being pursued. Computer-aided virtual screening and repurposing approved drugs are two such strategies that have shown recent success. Herein, we report the creation of a highly-curated in silico database of chemical structures representing approved drugs, chemical isolates from traditional medicinal herbs, and regulated chemicals, termed the SWEETLEAD database. The motivation for SWEETLEAD stems from the observance of conflicting information in publicly available chemical databases and the lack of a highly curated database of chemical structures for the globally approved drugs. A consensus building scheme surveying information from several publicly accessible databases was employed to identify the correct structure for each chemical. Resulting structures are filtered for the active pharmaceutical ingredient, standardized, and differing formulations of the same drug were combined in the final database. The publically available release of SWEETLEAD (https://simtk.org/home/sweetlead provides an important tool to enable the successful completion of computer-aided repurposing and drug discovery campaigns.

  8. DICOM standard in computer-aided medical technologies

    International Nuclear Information System (INIS)

    Plotnikov, A.V.; Prilutskij, D.A.; Selishchev, S.V.

    1997-01-01

    The paper outlines one of the promising standards to transmit images in medicine, in radiology in particular. the essence of the standard DICOM is disclosed and promises of its introduction into computer-aided medical technologies

  9. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    International Nuclear Information System (INIS)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R.; Lindenau, M.; Stodieck, S.; Fiehler, J.; Heese, O.

    2008-01-01

    Ictal perfusion SPECT with either 9 9mTc-hexamethylpropylene amine oxime (HMPAO) or 9 9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case

  10. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Nuclear Medicine; Lindenau, M.; Stodieck, S. [Protestant Hospital Alsterdorf, Hamburg (Germany). Dept. of Neurology and Epileptology; Fiehler, J. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Neuroradiology; Heese, O. [Univ. Medical Center Hamburg-Eppendorf (Germany). Neurological Surgery

    2008-07-01

    Ictal perfusion SPECT with either {sup 9}9mTc-hexamethylpropylene amine oxime (HMPAO) or {sup 9}9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case.

  11. A Fine-Grained and Privacy-Preserving Query Scheme for Fog Computing-Enhanced Location-Based Service.

    Science.gov (United States)

    Yang, Xue; Yin, Fan; Tang, Xiaohu

    2017-07-11

    Location-based services (LBS), as one of the most popular location-awareness applications, has been further developed to achieve low-latency with the assistance of fog computing. However, privacy issues remain a research challenge in the context of fog computing. Therefore, in this paper, we present a fine-grained and privacy-preserving query scheme for fog computing-enhanced location-based services, hereafter referred to as FGPQ. In particular, mobile users can obtain the fine-grained searching result satisfying not only the given spatial range but also the searching content. Detailed privacy analysis shows that our proposed scheme indeed achieves the privacy preservation for the LBS provider and mobile users. In addition, extensive performance analyses and experiments demonstrate that the FGPQ scheme can significantly reduce computational and communication overheads and ensure the low-latency, which outperforms existing state-of-the art schemes. Hence, our proposed scheme is more suitable for real-time LBS searching.

  12. Computer-Aided Drug Design in Epigenetics

    Science.gov (United States)

    Lu, Wenchao; Zhang, Rukang; Jiang, Hao; Zhang, Huimin; Luo, Cheng

    2018-03-01

    Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field.

  13. Computer-Aided Drug Design in Epigenetics

    Science.gov (United States)

    Lu, Wenchao; Zhang, Rukang; Jiang, Hao; Zhang, Huimin; Luo, Cheng

    2018-01-01

    Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation, and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field. PMID:29594101

  14. Computer-Aided Modelling Methods and Tools

    DEFF Research Database (Denmark)

    Cameron, Ian; Gani, Rafiqul

    2011-01-01

    The development of models for a range of applications requires methods and tools. In many cases a reference model is required that allows the generation of application specific models that are fit for purpose. There are a range of computer aided modelling tools available that help to define the m...

  15. Computer-aided translation tools

    DEFF Research Database (Denmark)

    Christensen, Tina Paulsen; Schjoldager, Anne

    2016-01-01

    in Denmark is rather high in general, but limited in the case of machine translation (MT) tools: While most TSPs use translation-memory (TM) software, often in combination with a terminology management system (TMS), only very few have implemented MT, which is criticised for its low quality output, especially......The paper reports on a questionnaire survey from 2013 of the uptake and use of computer-aided translation (CAT) tools by Danish translation service providers (TSPs) and discusses how these tools appear to have impacted on the Danish translation industry. According to our results, the uptake...

  16. [Development of computer aided forming techniques in manufacturing scaffolds for bone tissue engineering].

    Science.gov (United States)

    Wei, Xuelei; Dong, Fuhui

    2011-12-01

    To review recent advance in the research and application of computer aided forming techniques for constructing bone tissue engineering scaffolds. The literature concerning computer aided forming techniques for constructing bone tissue engineering scaffolds in recent years was reviewed extensively and summarized. Several studies over last decade have focused on computer aided forming techniques for bone scaffold construction using various scaffold materials, which is based on computer aided design (CAD) and bone scaffold rapid prototyping (RP). CAD include medical CAD, STL, and reverse design. Reverse design can fully simulate normal bone tissue and could be very useful for the CAD. RP techniques include fused deposition modeling, three dimensional printing, selected laser sintering, three dimensional bioplotting, and low-temperature deposition manufacturing. These techniques provide a new way to construct bone tissue engineering scaffolds with complex internal structures. With rapid development of molding and forming techniques, computer aided forming techniques are expected to provide ideal bone tissue engineering scaffolds.

  17. A virtual network computer's optical storage virtualization scheme

    Science.gov (United States)

    Wang, Jianzong; Hu, Huaixiang; Wan, Jiguang; Wang, Peng

    2008-12-01

    In this paper, we present the architecture and implementation of a virtual network computers' (VNC) optical storage virtualization scheme called VOSV. Its task is to manage the mapping of virtual optical storage to physical optical storage, a technique known as optical storage virtualization. The design of VOSV aims at the optical storage resources of different clients and servers that have high read-sharing patterns. VOSV uses several schemes such as a two-level Cache mechanism, a VNC server embedded module and the iSCSI protocols to improve the performance. The results measured on the prototype are encouraging, and indicating that VOSV provides the high I/O performance.

  18. An Adaptive Ship Detection Scheme for Spaceborne SAR Imagery

    Directory of Open Access Journals (Sweden)

    Xiangguang Leng

    2016-08-01

    Full Text Available With the rapid development of spaceborne synthetic aperture radar (SAR and the increasing need of ship detection, research on adaptive ship detection in spaceborne SAR imagery is of great importance. Focusing on practical problems of ship detection, this paper presents a highly adaptive ship detection scheme for spaceborne SAR imagery. It is able to process a wide range of sensors, imaging modes and resolutions. Two main stages are identified in this paper, namely: ship candidate detection and ship discrimination. Firstly, this paper proposes an adaptive land masking method using ship size and pixel size. Secondly, taking into account the imaging mode, incidence angle, and polarization channel of SAR imagery, it implements adaptive ship candidate detection in spaceborne SAR imagery by applying different strategies to different resolution SAR images. Finally, aiming at different types of typical false alarms, this paper proposes a comprehensive ship discrimination method in spaceborne SAR imagery based on confidence level and complexity analysis. Experimental results based on RADARSAT-1, RADARSAT-2, TerraSAR-X, RS-1, and RS-3 images demonstrate that the adaptive scheme proposed in this paper is able to detect ship targets in a fast, efficient and robust way.

  19. Computer-aided detection of pulmonary embolism: Influence on radiologists' detection performance with respect to vessel segments

    International Nuclear Information System (INIS)

    Das, Marco; Muehlenbruch, Georg; Helm, Anita; Guenther, Rolf W.; Wildberger, Joachim E.; Bakai, Annemarie; Salganicoff, Marcos; Liang, Jianming; Wolf, Matthias; Stanzel, Sven

    2008-01-01

    The purpose was to assess the sensitivity of a CAD software prototype for the detection of pulmonary embolism in MDCT chest examinations with regard to vessel level and to assess the influence on radiologists' detection performance. Forty-three patients with suspected PE were included in this retrospective study. MDCT chest examinations with a standard PE protocol were acquired at a 16-slice MDCT. All patient data were read by three radiologists (R1, R2, R3), and all thrombi were marked. A CAD prototype software was applied to all datasets, and each finding of the software was analyzed with regard to vessel level. The standard of reference was assessed in a consensus read. Sensitivity for the radiologists and CAD software was assessed. Thirty-three patients were positive for PE, with a total of 215 thrombi. The mean overall sensitivity for the CAD software alone was 83% (specificity, 80%). Radiologist sensitivity was 77% = R3, 82% = R2, and R1 = 87%. With the aid of the CAD software, sensitivities increased to 98% (R1), 93% (R2), and 92% (R3) (p<0.0001). CAD performance at the lobar level was 87%, at the segmental 90% and at the subsegmental 77%. With the use of CAD for PE, the detection performance of radiologists can be improved. (orig.)

  20. Anomaly Detection for Internet of Vehicles: A Trust Management Scheme with Affinity Propagation

    Directory of Open Access Journals (Sweden)

    Shu Yang

    2016-01-01

    Full Text Available Anomaly detection is critical for intelligent vehicle (IV collaboration. Forming clusters/platoons, IVs can work together to accomplish complex jobs that they are unable to perform individually. To improve security and efficiency of Internet of Vehicles, IVs’ anomaly detection has been extensively studied and a number of trust-based approaches have been proposed. However, most of these proposals either pay little attention to leader-based detection algorithm or ignore the utility of networked Roadside-Units (RSUs. In this paper, we introduce a trust-based anomaly detection scheme for IVs, where some malicious or incapable vehicles are existing on roads. The proposed scheme works by allowing IVs to detect abnormal vehicles, communicate with each other, and finally converge to some trustworthy cluster heads (CHs. Periodically, the CHs take responsibility for intracluster trust management. Moreover, the scheme is enhanced with a distributed supervising mechanism and a central reputation arbitrator to assure robustness and fairness in detecting process. The simulation results show that our scheme can achieve a low detection failure rate below 1%, demonstrating its ability to detect and filter the abnormal vehicles.

  1. A computer-aided software-tool for sustainable process synthesis-intensification

    DEFF Research Database (Denmark)

    Kumar Tula, Anjan; Babi, Deenesh K.; Bottlaender, Jack

    2017-01-01

    and determine within the design space, the more sustainable processes. In this paper, an integrated computer-aided software-tool that searches the design space for hybrid/intensified more sustainable process options is presented. Embedded within the software architecture are process synthesis...... operations as well as reported hybrid/intensified unit operations is large and can be difficult to manually navigate in order to determine the best process flowsheet for the production of a desired chemical product. Therefore, it is beneficial to utilize computer-aided methods and tools to enumerate, analyze...... constraints while also matching the design targets, they are therefore more sustainable than the base case. The application of the software-tool to the production of biodiesel is presented, highlighting the main features of the computer-aided, multi-stage, multi-scale methods that are able to determine more...

  2. Computer-aided dental prostheses construction using reverse engineering.

    Science.gov (United States)

    Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O

    2014-01-01

    The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.

  3. Time-efficient CT colonography interpretation using an advanced image-gallery-based, computer-aided ''first-reader'' workflow for the detection of colorectal adenomas

    International Nuclear Information System (INIS)

    Mang, Thomas; Ringl, Helmut; Weber, Michael; Mueller-Mang, Christina; Hermosillo, Gerardo; Wolf, Matthias; Bogoni, Luca; Salganicoff, Marcos; Raykar, Vikas; Graser, Anno

    2012-01-01

    To assess the performance of an advanced ''first-reader'' workflow for computer-aided detection (CAD) of colorectal adenomas ≥ 6 mm at computed tomographic colonography (CTC) in a low-prevalence cohort. A total of 616 colonoscopy-validated CTC patient-datasets were retrospectively reviewed by a radiologist using a ''first-reader'' CAD workflow. CAD detections were presented as galleries of six automatically generated two-dimensional (2D) and three-dimensional (3D) images together with interactive 3D target views and 2D multiplanar views of the complete dataset. Each patient-dataset was interpreted by initially using CAD image-galleries followed by a fast 2D review to address unprompted colonic areas. Per-patient, per-polyp, and per-adenoma sensitivities were calculated for lesions ≥ 6 mm. Statistical testing employed Fisher's exact and McNemar tests. In 91/616 patients, 131 polyps (92 adenomas, 39 non-adenomas) ≥ 6 mm and two cancers were identified by reference standard. Using the CAD gallery-based first-reader workflow, the radiologist detected all adenomas ≥ 10 mm (34/34) and cancers. Per-patient and polyp sensitivities for lesions ≥ 6 mm were 84.3 % (75/89), and 83.2 % (109/131), respectively, with 89.1 % (57/64) and 85.9 % (79/92) for adenomas. Overall specificity was 95.6 % (504/527). Mean interpretation time was 3.1 min per patient. A CAD algorithm, applied in an image-gallery-based first-reader workflow, can substantially decrease reading times while enabling accurate detection of colorectal adenomas in a low-prevalence population. (orig.)

  4. Estimation of the failure risk of a maxillary premolar with different crack depths with endodontic treatment by computer-aided design/computer-aided manufacturing ceramic restorations.

    Science.gov (United States)

    Lin, Chun-Li; Chang, Yen-Hsiang; Hsieh, Shih-Kai; Chang, Wen-Jen

    2013-03-01

    This study evaluated the risk of failure for an endodontically treated premolar with different crack depths, which was shearing toward the pulp chamber and was restored by using 3 different computer-aided design/computer-aided manufacturing ceramic restoration configurations. Three 3-dimensional finite element models designed with computer-aided design/computer-aided manufacturing ceramic onlay, endocrown, and conventional crown restorations were constructed to perform simulations. The Weibull function was incorporated with finite element analysis to calculate the long-term failure probability relative to different load conditions. The results indicated that the stress values on the enamel, dentin, and luting cement for endocrown restorations exhibited the lowest values relative to the other 2 restoration methods. Weibull analysis revealed that the overall failure probabilities in a shallow cracked premolar were 27%, 2%, and 1% for the onlay, endocrown, and conventional crown restorations, respectively, in the normal occlusal condition. The corresponding values were 70%, 10%, and 2% for the depth cracked premolar. This numeric investigation suggests that the endocrown provides sufficient fracture resistance only in a shallow cracked premolar with endodontic treatment. The conventional crown treatment can immobilize the premolar for different cracked depths with lower failure risk. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. The computer-aided design of rubber-metal products

    Directory of Open Access Journals (Sweden)

    Pavlo S. Shvets

    2015-12-01

    Full Text Available The important problem in design of rubber-metal products is the optimization of their mass without sacrificing of proportionality factor is in the limits of standard. Aim: The aim of this work is to improve the computer-aided systems by development and implementation of improved optimization method in rubber-metal CAD systems for designers based on the reverse optimization. Materials and Methods: The paper studies the matters of computer-aided structural design of technical composite products composed of anisotropic materials that are essentially different in properties. Results: The structure of CAD systems for designers solving the problems of such design is offered and the work principles of its subsystems are described. It is shown that complicated systems optimization in CAD systems must consider as restrictions the entitative connection between separate elements of these systems within the area of the optimizing arguments. Conclusions: The problem of the “reverse” optimization when objective functions are the connectivity area parameters is considered. In many cases, this allows receiving solutions that are more effective during the computer-aided design process. The developed CAD system for designers was used during the production of rubber-metal shock absorbers at the Odessa Rubber Technical Articles Plant. The positive technical and economic effect was obtained.

  6. Computer-Aided Drug Design in Epigenetics

    Directory of Open Access Journals (Sweden)

    Wenchao Lu

    2018-03-01

    Full Text Available Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation, and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field.

  7. Computer-Aided Engineering Education at the K.U. Leuven.

    Science.gov (United States)

    Snoeys, R.; Gobin, R.

    1987-01-01

    Describes some recent initiatives and developments in the computer-aided design program in the engineering faculty of the Katholieke Universiteit Leuven (Belgium). Provides a survey of the engineering curriculum, the computer facilities, and the main software packages available. (TW)

  8. Framework for computer-aided systems design

    International Nuclear Information System (INIS)

    Esselman, W.H.

    1992-01-01

    Advanced computer technology, analytical methods, graphics capabilities, and expert systems contribute to significant changes in the design process. Continued progress is expected. Achieving the ultimate benefits of these computer-based design tools depends on successful research and development on a number of key issues. A fundamental understanding of the design process is a prerequisite to developing these computer-based tools. In this paper a hierarchical systems design approach is described, and methods by which computers can assist the designer are examined. A framework is presented for developing computer-based design tools for power plant design. These tools include expert experience bases, tutorials, aids in decision making, and tools to develop the requirements, constraints, and interactions among subsystems and components. Early consideration of the functional tasks is encouraged. Methods of acquiring an expert's experience base is a fundamental research problem. Computer-based guidance should be provided in a manner that supports the creativity, heuristic approaches, decision making, and meticulousness of a good designer

  9. Impact on breast cancer diagnosis in a multidisciplinary unit after the incorporation of mammography digitalization and computer-aided detection systems.

    Science.gov (United States)

    Romero, Cristina; Varela, Celia; Muñoz, Enriqueta; Almenar, Asunción; Pinto, Jose María; Botella, Miguel

    2011-12-01

    The purpose of this article is to evaluate the impact on the diagnosis of breast cancer of implementing full-field digital mammography (FFDM) in a multidisciplinary breast pathology unit and, 1 year later, the addition of a computer-aided detection (CAD) system. A total of 13,453 mammograms performed between January and July of the years 2004, 2006, and 2007 were retrospectively reviewed using conventional mammography, digital mammography, and digital mammography plus CAD techniques. Mammograms were classified into two subsets: screening and diagnosis. Variables analyzed included cancer detection rate, rate of in situ carcinoma, tumor size at detection, biopsy rate, and positive predictive value of biopsy. FFDM increased the cancer detection rate, albeit not statistically significantly. The detection rate of in situ carcinoma increased significantly using FFDM plus CAD compared with conventional technique (36.8% vs 6.7%; p = 0.05 without Bonferroni statistical correction) for the screening dataset. Relative to conventional mammography, tumor size at detection decreased with digital mammography (T1, 61.5% vs 88%; p = 0.018) and with digital mammography plus CAD (T1, 79.7%; p = 0.03 without Bonferroni statistical correction). Biopsy rates in the general population increased significantly using CAD (10.6/1000 for conventional mammography, 14.7/1000 for digital mammography, and 17.9/1000 for digital mammography plus CAD; p = 0.02). The positive predictive value of biopsy decreased slightly, but not significantly, for both subsets. The incorporation of new techniques has improved the performance of the breast unit by increasing the overall detection rates and earlier detection (smaller tumors), both leading to an increase in interventionism.

  10. Development of a computer-aided digital reactivity computer system for PWRs

    International Nuclear Information System (INIS)

    Chung, S.-K.; Sung, K.-Y.; Kim, D.; Cho, D.-Y.

    1993-01-01

    Reactor physics tests at initial startup and after reloading are performed to verify nuclear design and to ensure safety operation. Two kinds of reactivity computers, analog and digital, have been widely used in the pressurized water reactor (PWR) core physics test. The test data of both reactivity computers are displayed only on the strip chart recorder, and these data are managed by hand so that the accuracy of the test results depends on operator expertise and experiences. This paper describes the development of the computer-aided digital reactivity computer system (DRCS), which is enhanced by system management software and an improved system for the application of the PWR core physics test

  11. Computer-Aided Diagnosis Systems for Brain Diseases in Magnetic Resonance Images

    Directory of Open Access Journals (Sweden)

    Yasuo Yamashita

    2009-07-01

    Full Text Available This paper reviews the basics and recent researches of computer-aided diagnosis (CAD systems for assisting neuroradiologists in detection of brain diseases, e.g., asymptomatic unruptured aneurysms, Alzheimer's disease, vascular dementia, and multiple sclerosis (MS, in magnetic resonance (MR images. The CAD systems consist of image feature extraction based on image processing techniques and machine learning classifiers such as linear discriminant analysis, artificial neural networks, and support vector machines. We introduce useful examples of the CAD systems in the neuroradiology, and conclude with possibilities in the future of the CAD systems for brain diseases in MR images.

  12. SOFTWARE FOR COMPUTER-AIDED DESIGN OF CROSS-WEDGE ROLLING

    OpenAIRE

    A. A. Abramov; S. V. Medvedev

    2013-01-01

    The issues of computer technology creation of 3D-design and engineering analysis of metal forming processes using cross wedge rolling methods (CWR) are considered. The developed software for computer-aided design and simulation of cross-wedge rolling is described.

  13. Unit cell-based computer-aided manufacturing system for tissue engineering

    International Nuclear Information System (INIS)

    Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo

    2012-01-01

    Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering. (paper)

  14. Unit cell-based computer-aided manufacturing system for tissue engineering.

    Science.gov (United States)

    Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo

    2012-03-01

    Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering.

  15. Computer-Aided Design in Further Education.

    Science.gov (United States)

    Ingham, Peter, Ed.

    This publication updates the 1982 occasional paper that was intended to foster staff awareness and assist colleges in Great Britain considering the use of computer-aided design (CAD) material in engineering courses. The paper begins by defining CAD and its place in the Integrated Business System with a brief discussion of the effect of CAD on the…

  16. Computer-aided global breast MR image feature analysis for prediction of tumor response to chemotherapy: performance assessment

    Science.gov (United States)

    Aghaei, Faranak; Tan, Maxine; Hollingsworth, Alan B.; Zheng, Bin; Cheng, Samuel

    2016-03-01

    Dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI) has been used increasingly in breast cancer diagnosis and assessment of cancer treatment efficacy. In this study, we applied a computer-aided detection (CAD) scheme to automatically segment breast regions depicting on MR images and used the kinetic image features computed from the global breast MR images acquired before neoadjuvant chemotherapy to build a new quantitative model to predict response of the breast cancer patients to the chemotherapy. To assess performance and robustness of this new prediction model, an image dataset involving breast MR images acquired from 151 cancer patients before undergoing neoadjuvant chemotherapy was retrospectively assembled and used. Among them, 63 patients had "complete response" (CR) to chemotherapy in which the enhanced contrast levels inside the tumor volume (pre-treatment) was reduced to the level as the normal enhanced background parenchymal tissues (post-treatment), while 88 patients had "partially response" (PR) in which the high contrast enhancement remain in the tumor regions after treatment. We performed the studies to analyze the correlation among the 22 global kinetic image features and then select a set of 4 optimal features. Applying an artificial neural network trained with the fusion of these 4 kinetic image features, the prediction model yielded an area under ROC curve (AUC) of 0.83+/-0.04. This study demonstrated that by avoiding tumor segmentation, which is often difficult and unreliable, fusion of kinetic image features computed from global breast MR images without tumor segmentation can also generate a useful clinical marker in predicting efficacy of chemotherapy.

  17. Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing.

    Science.gov (United States)

    Oh, Ji-Hyeon

    2018-12-01

    With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

  18. Computer-Aided Detection in Digital Mammography: False-Positive Marks and Their Reproducibility in Negative Mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Chang, Jung Min; Seong, Min Hyun

    2009-01-01

    Background: There are relatively few studies reporting the frequency of false-positive computer-aided detection (CAD) marks and their reproducibility in normal cases. Purpose: To evaluate retrospectively the false-positive mark rate of a CAD system and the reproducibility of false-positive marks in two sets of negative digital mammograms. Material and Methods: Two sets of negative digital mammograms were obtained in 360 women (mean age 57 years, range 30-76 years) with an approximate interval of 1 year (mean time 343.7 days), and a CAD system was applied. False-positive CAD marks and the reproducibility were determined. Results: Of the 360 patients, 252 (70.0%) and 240 (66.7%) patients had 1-7 CAD marks on the initial and second mammograms, respectively. The false-positive CAD mark rate was 1.5 (1.1 for masses and 0.4 for calcifications) and 1.4 (1.0 for masses and 0.4 for calcifications) per examination in the initial and second mammograms, respectively. The reproducibility of the false-positive CAD marks was 12.0% for both mass (81/680) and microcalcification (33/278) marks. Conclusion: False-positive CAD marks were seen in approximately 70% of normal cases. However, the reproducibility was very low. Radiologists must be familiar with the findings of false-positive CAD marks, since they are very common and can increase the recall rate in screening

  19. Computer-aided proofs for multiparty computation with active security

    DEFF Research Database (Denmark)

    Haagh, Helene; Karbyshev, Aleksandr; Oechsner, Sabine

    2018-01-01

    Secure multi-party computation (MPC) is a general cryptographic technique that allows distrusting parties to compute a function of their individual inputs, while only revealing the output of the function. It has found applications in areas such as auctioning, email filtering, and secure...... teleconference. Given its importance, it is crucial that the protocols are specified and implemented correctly. In the programming language community it has become good practice to use computer proof assistants to verify correctness proofs. In the field of cryptography, EasyCrypt is the state of the art proof...... public-key encryption, signatures, garbled circuits and differential privacy. Here we show for the first time that it can also be used to prove security of MPC against a malicious adversary. We formalize additive and replicated secret sharing schemes and apply them to Maurer's MPC protocol for secure...

  20. Enabling Lean Design Through Computer Aided Synthesis: The Injection Moulding Cooling Case

    NARCIS (Netherlands)

    Jauregui Becker, Juan Manuel; Wits, Wessel Willems

    2015-01-01

    This paper explores the application of Computer Aided Synthesis (CAS) to support the implementation of Set-Based Concurrent Engineering (SBCE) and Just In Time Decision Making (JIT-DM), which are considered as two of the cornerstones of the Lean Design method. Computer Aided Synthesis refers to a

  1. Computer Aided Continuous Time Stochastic Process Modelling

    DEFF Research Database (Denmark)

    Kristensen, N.R.; Madsen, Henrik; Jørgensen, Sten Bay

    2001-01-01

    A grey-box approach to process modelling that combines deterministic and stochastic modelling is advocated for identification of models for model-based control of batch and semi-batch processes. A computer-aided tool designed for supporting decision-making within the corresponding modelling cycle...

  2. Diagnóstico auxiliado por computador na radiologia Computer-aided diagnosis in radiology

    Directory of Open Access Journals (Sweden)

    Paulo Mazzoncini de Azevedo-Marques

    2001-10-01

    Full Text Available Vários desenvolvimentos tecnológicos estão convergindo de forma a aumentar a influência da área de imagens nas pesquisas biomédicas e na medicina clínica. Muitos pesquisadores têm trabalhado no desenvolvimento de sistemas computadorizados para detecção automatizada e quantificação de anormalidades em imagens radiológicas. Estes sistemas são dedicados ao diagnóstico auxiliado por computador. Este artigo discute os conceitos básicos relacionados ao diagnóstico auxiliado por computador e apresenta uma revisão bibliográfica sobre o assunto.Several technological developments are contributing to increase the use of imaging techniques in biomedical research and clinical medicine. Many investigators have attempted to develop computerized routines for automated detection and quantitative analysis of abnormalities in radiological images. These routines have been referred to as computer-aided diagnosis. In this paper we discuss the basic concepts of computer-aided diagnosis and review the literature.

  3. The finite precision computation and the nonconvergence of difference scheme

    OpenAIRE

    Pengfei, Wang; Jianping, Li

    2008-01-01

    The authors show that the round-off error can break the consistency which is the premise of using the difference equation to replace the original differential equations. We therefore proposed a theoretical approach to investigate this effect, and found that the difference scheme can not guarantee the convergence of the actual compute result to the analytical one. A conservation scheme experiment is applied to solve a simple linear differential equation satisfing the LAX equivalence theorem in...

  4. A Secure and Verifiable Outsourced Access Control Scheme in Fog-Cloud Computing.

    Science.gov (United States)

    Fan, Kai; Wang, Junxiong; Wang, Xin; Li, Hui; Yang, Yintang

    2017-07-24

    With the rapid development of big data and Internet of things (IOT), the number of networking devices and data volume are increasing dramatically. Fog computing, which extends cloud computing to the edge of the network can effectively solve the bottleneck problems of data transmission and data storage. However, security and privacy challenges are also arising in the fog-cloud computing environment. Ciphertext-policy attribute-based encryption (CP-ABE) can be adopted to realize data access control in fog-cloud computing systems. In this paper, we propose a verifiable outsourced multi-authority access control scheme, named VO-MAACS. In our construction, most encryption and decryption computations are outsourced to fog devices and the computation results can be verified by using our verification method. Meanwhile, to address the revocation issue, we design an efficient user and attribute revocation method for it. Finally, analysis and simulation results show that our scheme is both secure and highly efficient.

  5. A Secure and Verifiable Outsourced Access Control Scheme in Fog-Cloud Computing

    Science.gov (United States)

    Fan, Kai; Wang, Junxiong; Wang, Xin; Li, Hui; Yang, Yintang

    2017-01-01

    With the rapid development of big data and Internet of things (IOT), the number of networking devices and data volume are increasing dramatically. Fog computing, which extends cloud computing to the edge of the network can effectively solve the bottleneck problems of data transmission and data storage. However, security and privacy challenges are also arising in the fog-cloud computing environment. Ciphertext-policy attribute-based encryption (CP-ABE) can be adopted to realize data access control in fog-cloud computing systems. In this paper, we propose a verifiable outsourced multi-authority access control scheme, named VO-MAACS. In our construction, most encryption and decryption computations are outsourced to fog devices and the computation results can be verified by using our verification method. Meanwhile, to address the revocation issue, we design an efficient user and attribute revocation method for it. Finally, analysis and simulation results show that our scheme is both secure and highly efficient. PMID:28737733

  6. [Computer-aided prescribing: from utopia to reality].

    Science.gov (United States)

    Suárez-Varela Ubeda, J; Beltrán Calvo, C; Molina López, T; Navarro Marín, P

    2005-05-31

    To determine whether the introduction of computer-aided prescribing helped reduce the administrative burden at primary care centers. Descriptive, cross-sectional design. Torreblanca Health Center in the province of Seville, southern Spain. From 29 October 2003 to the present a pilot project involving nine pharmacies in the basic health zone served by this health center has been running to evaluate computer-aided prescribing (the Receta XXI project) with real patients. All patients on the center's list of patients who came to the center for an administrative consultation to renew prescriptions for medications or supplies for long-term treatment. Total number of administrative visits per patient for patients who came to the center to renew prescriptions for long-term treatment, as recorded by the Diraya system (Historia Clinica Digital del Ciudadano, or Citizen's Digital Medical Record) during the period from February to July 2004. Total number of the same type of administrative visits recorded by the previous system (TASS) during the period from February to July 2003. The mean number of administrative visits per month during the period from February to July 2003 was 160, compared to a mean number of 64 visits during the period from February to July 2004. The reduction in the number of visits for prescription renewal was 60%. Introducing a system for computer-aided prescribing significantly reduced the number of administrative visits for prescription renewal for long-term treatment. This could help reduce the administrative burden considerably in primary care if the system were used in all centers.

  7. Teaching Computer-Aided Design of Fluid Flow and Heat Transfer Engineering Equipment.

    Science.gov (United States)

    Gosman, A. D.; And Others

    1979-01-01

    Describes a teaching program for fluid mechanics and heat transfer which contains both computer aided learning (CAL) and computer aided design (CAD) components and argues that the understanding of the physical and numerical modeling taught in the CAL course is essential to the proper implementation of CAD. (Author/CMV)

  8. Computer-Presented Organizational/Memory Aids as Instruction for Solving Pico-Fomi Problems.

    Science.gov (United States)

    Steinberg, Esther R.; And Others

    1985-01-01

    Describes investigation of effectiveness of computer-presented organizational/memory aids (matrix and verbal charts controlled by computer or learner) as instructional technique for solving Pico-Fomi problems, and the acquisition of deductive inference rules when such aids are present. Results indicate chart use control should be adapted to…

  9. Progress of computer-aided detection/diagnosis (CAD in dentistryCAD in dentistry

    Directory of Open Access Journals (Sweden)

    Akitoshi Katsumata

    2014-08-01

    CAD is also useful in the detection and evaluation of dental and maxillofacial lesions. Identifying alveolar bone resorption due to periodontitis and radiolucent jaw lesions (such as radicular and dentigerous cysts are important goals for CAD. CAD can be applied not only to panoramic radiography but also to dental cone-beam computed tomography (CBCT images. Linking of CAD and teleradiology will be an important issue.

  10. Computer-Aided Sensor Development Focused on Security Issues.

    Science.gov (United States)

    Bialas, Andrzej

    2016-05-26

    The paper examines intelligent sensor and sensor system development according to the Common Criteria methodology, which is the basic security assurance methodology for IT products and systems. The paper presents how the development process can be supported by software tools, design patterns and knowledge engineering. The automation of this process brings cost-, quality-, and time-related advantages, because the most difficult and most laborious activities are software-supported and the design reusability is growing. The paper includes a short introduction to the Common Criteria methodology and its sensor-related applications. In the experimental section the computer-supported and patterns-based IT security development process is presented using the example of an intelligent methane detection sensor. This process is supported by an ontology-based tool for security modeling and analyses. The verified and justified models are transferred straight to the security target specification representing security requirements for the IT product. The novelty of the paper is to provide a patterns-based and computer-aided methodology for the sensors development with a view to achieving their IT security assurance. The paper summarizes the validation experiment focused on this methodology adapted for the sensors system development, and presents directions of future research.

  11. Neural Computation Scheme of Compound Control: Tacit Learning for Bipedal Locomotion

    Science.gov (United States)

    Shimoda, Shingo; Kimura, Hidenori

    The growing need for controlling complex behaviors of versatile robots working in unpredictable environment has revealed the fundamental limitation of model-based control strategy that requires precise models of robots and environments before their operations. This difficulty is fundamental and has the same root with the well-known frame problem in artificial intelligence. It has been a central long standing issue in advanced robotics, as well as machine intelligence, to find a prospective clue to attack this fundamental difficulty. The general consensus shared by many leading researchers in the related field is that the body plays an important role in acquiring intelligence that can conquer unknowns. In particular, purposeful behaviors emerge during body-environment interactions with the help of an appropriately organized neural computational scheme that can exploit what the environment can afford. Along this line, we propose a new scheme of neural computation based on compound control which represents a typical feature of biological controls. This scheme is based on classical neuron models with local rules that can create macroscopic purposeful behaviors. This scheme is applied to a bipedal robot and generates the rhythm of walking without any model of robot dynamics and environments.

  12. In-vivo and ex-vivo assessment of the accuracy of the computer-aided volumetry of porcine kidney in CT images

    Energy Technology Data Exchange (ETDEWEB)

    Cai, W.; Harris, G.; Holalkere, N.; Sahani, D.; Yoshida, H. [Massachusetts General Hospital and Harvard Medical School (United States)

    2007-06-15

    Measurement of kidney volume by computed tomography (CT), called renal volumetry, is indispensable for diagnosis and treatment of kidney-related diseases. Computer-aided volumetry (CAV) of kidney relies on an efficient and accurate segmentation method of the kidney. The purpose of this study is to assess the accuracy of our CAV of kidney scheme using dynamic-threshold (DT) level set method, based on in-vivo and ex-vivo reference standards. Eight Yorkshire breed anesthetized pigs were scanned on a 64-slice multi-detector CT scanner (Sensation 64, Siemens) after an injection of iodinated (300 mgl/ml) contrast agent through an IV cannula. The kidneys of the pigs were then surgically resected and scanned on CT in the same manner. Both in-vivo and ex-vivo CT images were subjected to our volumetry scheme. The resulting volumes of the kidneys were compared with the in-vivo and ex-vivo reference standards: the former was established by manual contouring of the kidneys on the CT images by an experienced radiologist, and the latter was established as the water displacement volume of the resected kidney. Our CAV of kidney scheme demonstrated accurate in-vivo and ex-vivo measurement of kidney volume, despite a large difference between the two reference standards. (orig.)

  13. In-vivo and ex-vivo assessment of the accuracy of the computer-aided volumetry of porcine kidney in CT images

    International Nuclear Information System (INIS)

    Cai, W.; Harris, G.; Holalkere, N.; Sahani, D.; Yoshida, H.

    2007-01-01

    Measurement of kidney volume by computed tomography (CT), called renal volumetry, is indispensable for diagnosis and treatment of kidney-related diseases. Computer-aided volumetry (CAV) of kidney relies on an efficient and accurate segmentation method of the kidney. The purpose of this study is to assess the accuracy of our CAV of kidney scheme using dynamic-threshold (DT) level set method, based on in-vivo and ex-vivo reference standards. Eight Yorkshire breed anesthetized pigs were scanned on a 64-slice multi-detector CT scanner (Sensation 64, Siemens) after an injection of iodinated (300 mgl/ml) contrast agent through an IV cannula. The kidneys of the pigs were then surgically resected and scanned on CT in the same manner. Both in-vivo and ex-vivo CT images were subjected to our volumetry scheme. The resulting volumes of the kidneys were compared with the in-vivo and ex-vivo reference standards: the former was established by manual contouring of the kidneys on the CT images by an experienced radiologist, and the latter was established as the water displacement volume of the resected kidney. Our CAV of kidney scheme demonstrated accurate in-vivo and ex-vivo measurement of kidney volume, despite a large difference between the two reference standards. (orig.)

  14. Brain computed tomography of patients with HIV/AIDS before the ...

    African Journals Online (AJOL)

    Background: The objective is to study intracranial complications of HIV/AIDS using brain‑computed tomography in patients who presented with neurological features before the advent of subsidized HIV/AIDS treatment program with highly active antiretroviral therapy (HAART) in Nigeria. Materials and Methods: Retrospective ...

  15. Computer-aided diagnosis of colonic polyp by CT colonography

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki

    2007-01-01

    The outcome of National CT Colonography Trial, by American College of Radiology Imaging Network, 2006 (www.acrin.org/6664 protocol), possibly leads to the introduction of colorectal cancer screening in the US because CT colonography (CTCG) has been approved in the health insurance system. This paper describes the outline of computer-aided diagnosis (CAD) of colonic polyp by CTCG, its polyp detectability and future aspects. CTCG essentially derives from the virtual, abdominal 3D CT images and gives as many as about 500 images/patient, in the reading of which CAD support the expert. CAD technology in CTCG is said to have been essentially established in the first half of 2000s, which involves the cleansing of fecal tagging effect, extraction of the colonal wall from the image, detection of suspicious polyp, reduction of false-positive findings and displaying of the detected polyp. The detectability is thought to be at comparable level to expert's. The last displaying is done on the user-interface like Colon CAD Workstation. More efficient expert's reading with CAD, imaging without previous gut cleansing, detection of the flat lesion and further reduction of false-positive are the forthcoming tasks in clinical practice. Significance of CTCG is becoming in realization and its usage with CAD is thought to be more popular in Japan. (R.T.)

  16. Enhancing the Statistical Filtering Scheme to Detect False Negative Attacks in Sensor Networks

    Directory of Open Access Journals (Sweden)

    Muhammad Akram

    2017-06-01

    Full Text Available In this paper, we present a technique that detects both false positive and false negative attacks in statistical filtering-based wireless sensor networks. In statistical filtering scheme, legitimate reports are repeatedly verified en route before they reach the base station, which causes heavy energy consumption. While the original statistical filtering scheme detects only false reports, our proposed method promises to detect both attacks.

  17. ADAM: A computer program to simulate selective-breeding schemes for animals

    DEFF Research Database (Denmark)

    Pedersen, L D; Sørensen, A C; Henryon, M

    2009-01-01

    ADAM is a computer program that models selective breeding schemes for animals using stochastic simulation. The program simulates a population of animals and traces the genetic changes in the population under different selective breeding scenarios. It caters to different population structures......, genetic models, selection strategies, and mating designs. ADAM can be used to evaluate breeding schemes and generate genetic data to test statistical tools...

  18. Computerized detection of lung nodules by means of "virtual dual-energy" radiography.

    Science.gov (United States)

    Chen, Sheng; Suzuki, Kenji

    2013-02-01

    Major challenges in current computer-aided detection (CADe) schemes for nodule detection in chest radiographs (CXRs) are to detect nodules that overlap with ribs and/or clavicles and to reduce the frequent false positives (FPs) caused by ribs. Detection of such nodules by a CADe scheme is very important, because radiologists are likely to miss such subtle nodules. Our purpose in this study was to develop a CADe scheme with improved sensitivity and specificity by use of "virtual dual-energy" (VDE) CXRs where ribs and clavicles are suppressed with massive-training artificial neural networks (MTANNs). To reduce rib-induced FPs and detect nodules overlapping with ribs, we incorporated the VDE technology in our CADe scheme. The VDE technology suppressed rib and clavicle opacities in CXRs while maintaining soft-tissue opacity by use of the MTANN technique that had been trained with real dual-energy imaging. Our scheme detected nodule candidates on VDE images by use of a morphologic filtering technique. Sixty morphologic and gray-level-based features were extracted from each candidate from both original and VDE CXRs. A nonlinear support vector classifier was employed for classification of the nodule candidates. A publicly available database containing 140 nodules in 140 CXRs and 93 normal CXRs was used for testing our CADe scheme. All nodules were confirmed by computed tomography examinations, and the average size of the nodules was 17.8 mm. Thirty percent (42/140) of the nodules were rated "extremely subtle" or "very subtle" by a radiologist. The original scheme without VDE technology achieved a sensitivity of 78.6% (110/140) with 5 (1165/233) FPs per image. By use of the VDE technology, more nodules overlapping with ribs or clavicles were detected and the sensitivity was improved substantially to 85.0% (119/140) at the same FP rate in a leave-one-out cross-validation test, whereas the FP rate was reduced to 2.5 (583/233) per image at the same sensitivity level as the

  19. Computer aided design of solonoid magnets

    Energy Technology Data Exchange (ETDEWEB)

    DeOlivares, J.M.

    1978-06-01

    Computer programs utilizing Legendre functions and elliptic integral functions have been written to aid in the design of solenoid magnets. The field inside an axisymmetric magnet can be expanded in a converging power series of Legendre functions. The Legendre function approach is very useful for designing solenoid magnets with a high degree of field uniformity. This approach has been programed on the LBL CDC 7600 computer so that one can design an axisymmetric magnet which meets any desired field structure. Two examples of computer designed solenoids are presented. A computer program utilizing elliptic integral functions was also written for the LBL CDC 7600 computer. This method was used in a computer program to verify the results obtained from the Legendre approach and for field calculations within the conductor. The elliptic integral field calculations within the conductor showed that thin solenoids produce field peaking at the ends of the magnet. Computer data is generated for various magnet geometries and compared with theoretical predictions. Computer results and theoretical prediction both show that field peaking is reduced for longer coils, increased for thinner coils and field peaking is a logarithmic function of length, thickness and radius.

  20. Computer-Aided Characterization and Diagnosis of Diffuse Liver Diseases Based on Ultrasound Imaging: A Review.

    Science.gov (United States)

    Bharti, Puja; Mittal, Deepti; Ananthasivan, Rupa

    2016-04-19

    Diffuse liver diseases, such as hepatitis, fatty liver, and cirrhosis, are becoming a leading cause of fatality and disability all over the world. Early detection and diagnosis of these diseases is extremely important to save lives and improve effectiveness of treatment. Ultrasound imaging, a noninvasive diagnostic technique, is the most commonly used modality for examining liver abnormalities. However, the accuracy of ultrasound-based diagnosis depends highly on expertise of radiologists. Computer-aided diagnosis systems based on ultrasound imaging assist in fast diagnosis, provide a reliable "second opinion" for experts, and act as an effective tool to measure response of treatment on patients undergoing clinical trials. In this review, we first describe appearance of liver abnormalities in ultrasound images and state the practical issues encountered in characterization of diffuse liver diseases that can be addressed by software algorithms. We then discuss computer-aided diagnosis in general with features and classifiers relevant to diffuse liver diseases. In later sections of this paper, we review the published studies and describe the key findings of those studies. A concise tabular summary comparing image database, features extraction, feature selection, and classification algorithms presented in the published studies is also exhibited. Finally, we conclude with a summary of key findings and directions for further improvements in the areas of accuracy and objectiveness of computer-aided diagnosis. © The Author(s) 2016.

  1. Computer aids for plant operators

    International Nuclear Information System (INIS)

    Joly, J.P.

    1992-01-01

    For some time, particularly since the TMI accident, nuclear power plant operators have been aware of the difficulties involved in diagnosing accidents and returning plants to their stable, safe operating mode. There are various possible solutions to these problems: improve control organization during accident situations, rewrite control procedures, integrate safety engineers in shifts, improve control rooms, and implement additional computer aids. The purpose of this presentation is to describe the efforts undertaken by EDF over the last few years in this field

  2. Computer-Aided Detection with a Portable Electrocardiographic Recorder and Acceleration Sensors for Monitoring Obstructive Sleep Apnea

    Directory of Open Access Journals (Sweden)

    Ji-Won Baek

    2014-03-01

    Full Text Available Obstructive sleep apnea syndrome is a sleep-related breathing disorder that is caused by obstruction of the upper airway. This condition may be related with many clinical sequelae such as cardiovascular disease, high blood pressure, stroke, diabetes, and clinical depression. To diagnosis obstructive sleep apnea, in-laboratory full polysomnography is considered as a standard test to determine the severity of respiratory disturbance. However, polysomnography is expensive and complicated to perform. In this research, we explore a computer-aided diagnosis system with portable ECG equipment and tri-accelerometer (x, y, and z-axes that can automatically analyze biosignals and test for OSA. Traditional approaches to sleep apnea data analysis have been criticized; however, there are not enough suggestions to resolve the existing problems. As an effort to resolve this issue, we developed an approach to record ECG signals and abdominal movements induced by breathing by affixing ECG-enabled electrodes onto a triaxial accelerometer. With the two signals simultaneously measured, the apnea data obtained would be more accurate, relative to cases where a single signal is measured. This would be helpful in diagnosing OSA. Moreover, a useful feature point can be extracted from the two signals after applying a signal processing algorithm, and the extracted feature point can be applied in designing a computer-aided diagnosis algorithm using a machine learning technique.

  3. A novel computer-aided diagnosis system for breast MRI based on feature selection and ensemble learning.

    Science.gov (United States)

    Lu, Wei; Li, Zhe; Chu, Jinghui

    2017-04-01

    Breast cancer is a common cancer among women. With the development of modern medical science and information technology, medical imaging techniques have an increasingly important role in the early detection and diagnosis of breast cancer. In this paper, we propose an automated computer-aided diagnosis (CADx) framework for magnetic resonance imaging (MRI). The scheme consists of an ensemble of several machine learning-based techniques, including ensemble under-sampling (EUS) for imbalanced data processing, the Relief algorithm for feature selection, the subspace method for providing data diversity, and Adaboost for improving the performance of base classifiers. We extracted morphological, various texture, and Gabor features. To clarify the feature subsets' physical meaning, subspaces are built by combining morphological features with each kind of texture or Gabor feature. We tested our proposal using a manually segmented Region of Interest (ROI) data set, which contains 438 images of malignant tumors and 1898 images of normal tissues or benign tumors. Our proposal achieves an area under the ROC curve (AUC) value of 0.9617, which outperforms most other state-of-the-art breast MRI CADx systems. Compared with other methods, our proposal significantly reduces the false-positive classification rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Volume based DCE-MRI breast cancer detection with 3D visualization system

    International Nuclear Information System (INIS)

    Chia, F.K.; Sim, K.S.; Chong, S.S.; Tan, S.T.; Ting, H.Y.; Abbas, S.F.; Omar, S.

    2011-01-01

    In this paper, a computer aided design auto probing system is presented to detect breast lesions based on Dynamic contrast enhanced Magnetic resonance imaging (DCE-MRI) images. The system is proposed in order to aid the radiologists and doctors in the interpretation of MRI breast images and enhance the detection accuracy. A series of approaches are presented to enhance the detection accuracy and refine the breast region of interest (Roil) automatically. Besides, a semi-quantitative analysis is used to segment the breast lesions from selected breast Roil and classify the detected tumour is whether benign, suspicious or malignant. The entire breast Roil including the detected tumour will display in 3D. The methodology has been applied on 104 sets of digital imaging and communications in medicine (Dico) breast MRI datasets images. The biopsy results are verified by 2 radiologists from Hospital Malaysia. The experimental results are demonstrated the proposed scheme can precisely identify breast cancer regions with 93% accuracy. (author)

  5. DS-ARP: a new detection scheme for ARP spoofing attacks based on routing trace for ubiquitous environments.

    Science.gov (United States)

    Song, Min Su; Lee, Jae Dong; Jeong, Young-Sik; Jeong, Hwa-Young; Park, Jong Hyuk

    2014-01-01

    Despite the convenience, ubiquitous computing suffers from many threats and security risks. Security considerations in the ubiquitous network are required to create enriched and more secure ubiquitous environments. The address resolution protocol (ARP) is a protocol used to identify the IP address and the physical address of the associated network card. ARP is designed to work without problems in general environments. However, since it does not include security measures against malicious attacks, in its design, an attacker can impersonate another host using ARP spoofing or access important information. In this paper, we propose a new detection scheme for ARP spoofing attacks using a routing trace, which can be used to protect the internal network. Tracing routing can find the change of network movement path. The proposed scheme provides high constancy and compatibility because it does not alter the ARP protocol. In addition, it is simple and stable, as it does not use a complex algorithm or impose extra load on the computer system.

  6. Feature-guided analysis for reduction of false positives in CAD of polyps for computed tomographic colonography

    International Nuclear Information System (INIS)

    Naeppi, Janne; Yoshida, Hiroyuki

    2003-01-01

    We evaluated the effect of our novel technique of feature-guided analysis of polyps on the reduction of false-positive (FP) findings generated by our computer-aided diagnosis (CAD) scheme for the detection of polyps from computed tomography colonographic data sets. The detection performance obtained by use of feature-guided analysis in the segmentation and feature analysis of polyp candidates was compared with that obtained by use of our previously employed fuzzy clustering technique. We also evaluated the effect of a feature called modified gradient concentration (MGC) on the detection performance. A total of 144 data sets, representing prone and supine views of 72 patients that included 14 patients with 21 colorectal polyps 5-25 mm in diameter, were used in the evaluation. At a 100% by-patient (95% by-polyp) detection sensitivity, the FP rate of our CAD scheme with feature-guided analysis based on round-robin evaluation was 1.3 (1.5) FP detections per patient. This corresponds to a 70-75 % reduction in the number of FPs obtained by use of fuzzy clustering at the same sensitivity levels. Application of the MGC feature instead of our previously used gradient concentration feature did not improve the detection result. The results indicate that feature-guided analysis is useful for achieving high sensitivity and a low FP rate in our CAD scheme

  7. Software Engineering Techniques for Computer-Aided Learning.

    Science.gov (United States)

    Ibrahim, Bertrand

    1989-01-01

    Describes the process for developing tutorials for computer-aided learning (CAL) using a programing language rather than an authoring system. The workstation used is described, the use of graphics is discussed, the role of a local area network (LAN) is explained, and future plans are discussed. (five references) (LRW)

  8. A Protocol Layer Trust-Based Intrusion Detection Scheme for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2017-05-01

    Full Text Available This article proposes a protocol layer trust-based intrusion detection scheme for wireless sensor networks. Unlike existing work, the trust value of a sensor node is evaluated according to the deviations of key parameters at each protocol layer considering the attacks initiated at different protocol layers will inevitably have impacts on the parameters of the corresponding protocol layers. For simplicity, the paper mainly considers three aspects of trustworthiness, namely physical layer trust, media access control layer trust and network layer trust. The per-layer trust metrics are then combined to determine the overall trust metric of a sensor node. The performance of the proposed intrusion detection mechanism is then analyzed using the t-distribution to derive analytical results of false positive and false negative probabilities. Numerical analytical results, validated by simulation results, are presented in different attack scenarios. It is shown that the proposed protocol layer trust-based intrusion detection scheme outperforms a state-of-the-art scheme in terms of detection probability and false probability, demonstrating its usefulness for detecting cross-layer attacks.

  9. Computer Navigation-aided Resection of Sacral Chordomas

    Directory of Open Access Journals (Sweden)

    Yong-Kun Yang

    2016-01-01

    Full Text Available Background: Resection of sacral chordomas is challenging. The anatomy is complex, and there are often no bony landmarks to guide the resection. Achieving adequate surgical margins is, therefore, difficult, and the recurrence rate is high. Use of computer navigation may allow optimal preoperative planning and improve precision in tumor resection. The purpose of this study was to evaluate the safety and feasibility of computer navigation-aided resection of sacral chordomas. Methods: Between 2007 and 2013, a total of 26 patients with sacral chordoma underwent computer navigation-aided surgery were included and followed for a minimum of 18 months. There were 21 primary cases and 5 recurrent cases, with a mean age of 55.8 years old (range: 35-84 years old. Tumors were located above the level of the S3 neural foramen in 23 patients and below the level of the S3 neural foramen in 3 patients. Three-dimensional images were reconstructed with a computed tomography-based navigation system combined with the magnetic resonance images using the navigation software. Tumors were resected via a posterior approach assisted by the computer navigation. Mean follow-up was 38.6 months (range: 18-84 months. Results: Mean operative time was 307 min. Mean intraoperative blood loss was 3065 ml. For computer navigation, the mean registration deviation during surgery was 1.7 mm. There were 18 wide resections, 4 marginal resections, and 4 intralesional resections. All patients were alive at the final follow-up, with 2 (7.7% exhibiting tumor recurrence. The other 24 patients were tumor-free. The mean Musculoskeletal Tumor Society Score was 27.3 (range: 19-30. Conclusions: Computer-assisted navigation can be safely applied to the resection of the sacral chordomas, allowing execution of preoperative plans, and achieving good oncological outcomes. Nevertheless, this needs to be accomplished by surgeons with adequate experience and skill.

  10. Method of Computer-aided Instruction in Situation Control Systems

    Directory of Open Access Journals (Sweden)

    Anatoliy O. Kargin

    2013-01-01

    Full Text Available The article considers the problem of computer-aided instruction in context-chain motivated situation control system of the complex technical system behavior. The conceptual and formal models of situation control with practical instruction are considered. Acquisition of new behavior knowledge is presented as structural changes in system memory in the form of situational agent set. Model and method of computer-aided instruction represent formalization, based on the nondistinct theories by physiologists and cognitive psychologists.The formal instruction model describes situation and reaction formation and dependence on different parameters, effecting education, such as the reinforcement value, time between the stimulus, action and the reinforcement. The change of the contextual link between situational elements when using is formalized.The examples and results of computer instruction experiments of the robot device “LEGO MINDSTORMS NXT”, equipped with ultrasonic distance, touch, light sensors.

  11. Computer Aided Design System for Developing Musical Fountain Programs

    Institute of Scientific and Technical Information of China (English)

    刘丹; 张乃尧; 朱汉城

    2003-01-01

    A computer aided design system for developing musical fountain programs was developed with multiple functions such as intelligent design, 3-D animation, manual modification and synchronized motion to make the development process more efficient. The system first analyzed the music form and sentiment using many basic features of the music to select a basic fountain program. Then, this program is simulated with 3-D animation and modified manually to achieve the desired results. Finally, the program is transformed to a computer control program to control the musical fountain in time with the music. A prototype system for the musical fountain was also developed. It was tested with many styles of music and users were quite satisfied with its performance. By integrating various functions, the proposed computer aided design system for developing musical fountain programs greatly simplified the design of the musical fountain programs.

  12. Features of Computer-Based Decision Aids: Systematic Review, Thematic Synthesis, and Meta-Analyses

    Science.gov (United States)

    Krömker, Dörthe; Meguerditchian, Ari N; Tamblyn, Robyn

    2016-01-01

    Background Patient information and education, such as decision aids, are gradually moving toward online, computer-based environments. Considerable research has been conducted to guide content and presentation of decision aids. However, given the relatively new shift to computer-based support, little attention has been given to how multimedia and interactivity can improve upon paper-based decision aids. Objective The first objective of this review was to summarize published literature into a proposed classification of features that have been integrated into computer-based decision aids. Building on this classification, the second objective was to assess whether integration of specific features was associated with higher-quality decision making. Methods Relevant studies were located by searching MEDLINE, Embase, CINAHL, and CENTRAL databases. The review identified studies that evaluated computer-based decision aids for adults faced with preference-sensitive medical decisions and reported quality of decision-making outcomes. A thematic synthesis was conducted to develop the classification of features. Subsequently, meta-analyses were conducted based on standardized mean differences (SMD) from randomized controlled trials (RCTs) that reported knowledge or decisional conflict. Further subgroup analyses compared pooled SMDs for decision aids that incorporated a specific feature to other computer-based decision aids that did not incorporate the feature, to assess whether specific features improved quality of decision making. Results Of 3541 unique publications, 58 studies met the target criteria and were included in the thematic synthesis. The synthesis identified six features: content control, tailoring, patient narratives, explicit values clarification, feedback, and social support. A subset of 26 RCTs from the thematic synthesis was used to conduct the meta-analyses. As expected, computer-based decision aids performed better than usual care or alternative aids; however

  13. Features of Computer-Based Decision Aids: Systematic Review, Thematic Synthesis, and Meta-Analyses.

    Science.gov (United States)

    Syrowatka, Ania; Krömker, Dörthe; Meguerditchian, Ari N; Tamblyn, Robyn

    2016-01-26

    Patient information and education, such as decision aids, are gradually moving toward online, computer-based environments. Considerable research has been conducted to guide content and presentation of decision aids. However, given the relatively new shift to computer-based support, little attention has been given to how multimedia and interactivity can improve upon paper-based decision aids. The first objective of this review was to summarize published literature into a proposed classification of features that have been integrated into computer-based decision aids. Building on this classification, the second objective was to assess whether integration of specific features was associated with higher-quality decision making. Relevant studies were located by searching MEDLINE, Embase, CINAHL, and CENTRAL databases. The review identified studies that evaluated computer-based decision aids for adults faced with preference-sensitive medical decisions and reported quality of decision-making outcomes. A thematic synthesis was conducted to develop the classification of features. Subsequently, meta-analyses were conducted based on standardized mean differences (SMD) from randomized controlled trials (RCTs) that reported knowledge or decisional conflict. Further subgroup analyses compared pooled SMDs for decision aids that incorporated a specific feature to other computer-based decision aids that did not incorporate the feature, to assess whether specific features improved quality of decision making. Of 3541 unique publications, 58 studies met the target criteria and were included in the thematic synthesis. The synthesis identified six features: content control, tailoring, patient narratives, explicit values clarification, feedback, and social support. A subset of 26 RCTs from the thematic synthesis was used to conduct the meta-analyses. As expected, computer-based decision aids performed better than usual care or alternative aids; however, some features performed better than

  14. Memristor-Based Synapse Design and Training Scheme for Neuromorphic Computing Architecture

    Science.gov (United States)

    2012-06-01

    system level built upon the conventional Von Neumann computer architecture [2][3]. Developing the neuromorphic architecture at chip level by...SCHEME FOR NEUROMORPHIC COMPUTING ARCHITECTURE 5a. CONTRACT NUMBER FA8750-11-2-0046 5b. GRANT NUMBER N/A 5c. PROGRAM ELEMENT NUMBER 62788F 6...creation of memristor-based neuromorphic computing architecture. Rather than the existing crossbar-based neuron network designs, we focus on memristor

  15. A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation.

    Science.gov (United States)

    Chen, Xiaojun; Xu, Lu; Sun, Yi; Politis, Constantinus

    2016-11-01

    Currently, oral and maxillofacial surgery (OMFS) still poses a significant challenge for surgeons due to the anatomic complexity and limited field of view of the oral cavity. With the great development of computer technologies, he computer-aided surgery has been widely used for minimizing the risks and improving the precision of surgery. Areas covered: The major goal of this paper is to provide a comprehensive reference source of current and future development of computer-aided OMFS including surgical planning, simulation and navigation for relevant researchers. Expert commentary: Compared with the traditional OMFS, computer-aided OMFS overcomes the disadvantage that the treatment on the region of anatomically complex maxillofacial depends almost exclusively on the experience of the surgeon.

  16. A Novel Congestion Detection Scheme in TCP Over OBS Networks

    KAUST Repository

    Shihada, Basem

    2009-02-01

    This paper introduces a novel congestion detection scheme for high-bandwidth TCP flows over optical burst switching (OBS) networks, called statistical additive increase multiplicative decrease (SAIMD). SAIMD maintains and analyzes a number of previous round-trip time (RTTs) at the TCP senders in order to identify the confidence with which a packet loss event is due to network congestion. The confidence is derived by positioning short-term RTT in the spectrum of long-term historical RTTs. The derived confidence corresponding to the packet loss is then taken in the developed policy for TCP congestion window adjustment. We will show through extensive simulation that the proposed scheme can effectively solve the false congestion detection problem and significantly outperform the conventional TCP counterparts without losing fairness. The advantages gained in our scheme are at the expense of introducing more overhead in the SAIMD TCP senders. Based on the proposed congestion control algorithm, a throughput model is formulated, and is further verified by simulation results.

  17. Image communication scheme based on dynamic visual cryptography and computer generated holography

    Science.gov (United States)

    Palevicius, Paulius; Ragulskis, Minvydas

    2015-01-01

    Computer generated holograms are often exploited to implement optical encryption schemes. This paper proposes the integration of dynamic visual cryptography (an optical technique based on the interplay of visual cryptography and time-averaging geometric moiré) with Gerchberg-Saxton algorithm. A stochastic moiré grating is used to embed the secret into a single cover image. The secret can be visually decoded by a naked eye if only the amplitude of harmonic oscillations corresponds to an accurately preselected value. The proposed visual image encryption scheme is based on computer generated holography, optical time-averaging moiré and principles of dynamic visual cryptography. Dynamic visual cryptography is used both for the initial encryption of the secret image and for the final decryption. Phase data of the encrypted image are computed by using Gerchberg-Saxton algorithm. The optical image is decrypted using the computationally reconstructed field of amplitudes.

  18. Prosthetic rehabilitation with an implant-supported fixed prosthesis using computer-aided design and computer-aided manufacturing dental technology for a patient with a mandibulectomy: A clinical report.

    Science.gov (United States)

    Yoon, Hyung-In; Han, Jung-Suk

    2016-02-01

    The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. A soft computing scheme incorporating ANN and MOV energy in fault detection, classification and distance estimation of EHV transmission line with FSC.

    Science.gov (United States)

    Khadke, Piyush; Patne, Nita; Singh, Arvind; Shinde, Gulab

    2016-01-01

    In this article, a novel and accurate scheme for fault detection, classification and fault distance estimation for a fixed series compensated transmission line is proposed. The proposed scheme is based on artificial neural network (ANN) and metal oxide varistor (MOV) energy, employing Levenberg-Marquardt training algorithm. The novelty of this scheme is the use of MOV energy signals of fixed series capacitors (FSC) as input to train the ANN. Such approach has never been used in any earlier fault analysis algorithms in the last few decades. Proposed scheme uses only single end measurement energy signals of MOV in all the 3 phases over one cycle duration from the occurrence of a fault. Thereafter, these MOV energy signals are fed as input to ANN for fault distance estimation. Feasibility and reliability of the proposed scheme have been evaluated for all ten types of fault in test power system model at different fault inception angles over numerous fault locations. Real transmission system parameters of 3-phase 400 kV Wardha-Aurangabad transmission line (400 km) with 40 % FSC at Power Grid Wardha Substation, India is considered for this research. Extensive simulation experiments show that the proposed scheme provides quite accurate results which demonstrate complete protection scheme with high accuracy, simplicity and robustness.

  20. Advanced neural network-based computational schemes for robust fault diagnosis

    CERN Document Server

    Mrugalski, Marcin

    2014-01-01

    The present book is devoted to problems of adaptation of artificial neural networks to robust fault diagnosis schemes. It presents neural networks-based modelling and estimation techniques used for designing robust fault diagnosis schemes for non-linear dynamic systems. A part of the book focuses on fundamental issues such as architectures of dynamic neural networks, methods for designing of neural networks and fault diagnosis schemes as well as the importance of robustness. The book is of a tutorial value and can be perceived as a good starting point for the new-comers to this field. The book is also devoted to advanced schemes of description of neural model uncertainty. In particular, the methods of computation of neural networks uncertainty with robust parameter estimation are presented. Moreover, a novel approach for system identification with the state-space GMDH neural network is delivered. All the concepts described in this book are illustrated by both simple academic illustrative examples and practica...

  1. The use of the MacCormack scheme in computational hydraulics

    International Nuclear Information System (INIS)

    Garcia, R.; Zhang, H.; Kahawita, R.

    1985-01-01

    This manuscript describes the development of a numerical model that solves shallow water problems based upon an enhanced version of the MacCormack explicit scheme (MS). The MS has been successfully applied to solve numerous problems in gas dynamics. However, the standard application of the MS to solve the shallow water equations can cause in certain test cases non-linear instabilities and non-symmetrical results that eventually destroy the solution. By examining the calculation 'cell' one can show that the MS is not symmetric in space, which explains why it cannot be used directly in the treatment of hydraulic problems most of which possess irregular boundaries thereby resulting in a flow with no 'preferred direction'. This is contrary to what is usually encountered in aerodynamics. The enhanced MacCormack scheme is obtained by a simple modification to the original formulation resulting in a symmetric scheme. The scheme has been applied to the computation of the flowfield in a real life situation with satisfactory results. (author)

  2. Online LDA BASED brain-computer interface system to aid disabled people

    Directory of Open Access Journals (Sweden)

    Apdullah Yayık

    2017-06-01

    Full Text Available This paper aims to develop brain-computer interface system based on electroencephalography that can aid disabled people in daily life. The system relies on one of the most effective event-related potential wave, P300, which can be elicited by oddball paradigm. Developed application has a basic interaction tool that enables disabled people to convey their needs to other people selecting related objects. These objects pseudo-randomly flash in a visual interface on computer screen. The user must focus on related object to convey desired needs. The system can convey desired needs correctly by detecting P300 wave in acquired 14-channel EEG signal and classifying using linear discriminant analysis classifier just in 15 seconds. Experiments have been carried out on 19 volunteers to validate developed BCI system. As a result, accuracy rate of 90.83% is achieved in online performance.

  3. Does computer-aided surgical simulation improve efficiency in bimaxillary orthognathic surgery?

    Science.gov (United States)

    Schwartz, H C

    2014-05-01

    The purpose of this study was to compare the efficiency of bimaxillary orthognathic surgery using computer-aided surgical simulation (CASS), with cases planned using traditional methods. Total doctor time was used to measure efficiency. While costs vary widely in different localities and in different health schemes, time is a valuable and limited resource everywhere. For this reason, total doctor time is a more useful measure of efficiency than is cost. Even though we use CASS primarily for planning more complex cases at the present time, this study showed an average saving of 60min for each case. In the context of a department that performs 200 bimaxillary cases each year, this would represent a saving of 25 days of doctor time, if applied to every case. It is concluded that CASS offers great potential for improving efficiency when used in the planning of bimaxillary orthognathic surgery. It saves significant doctor time that can be applied to additional surgical work. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Retrospective analysis of a Computer-Aided Detection (CAD) system in full-field digital mammography in correlation to tumor histology

    International Nuclear Information System (INIS)

    Obenauer, S.; Sohns, C.; Grabbe, E.; Werner, C.

    2005-01-01

    Purpose: to evaluate the usefulness of a computer-aided detection (CAD) system in full-field digital mammography in correlation to tumor histology. Material and methods: a total of 476 patients (226 patients with histologically proven malignant tumors, 250 healthy women) took part in this study. The mammograms were studied retrospectively, using the CAD system Image Checker. For 226 patients digital mammograms in MLO-projection were available. For 186 of these patients the CC-projection was also available. CAD markers that correlated with histologically proven carcinomas were considered to be true-positive markers. All other CAD markers were considered to be false-positive. Histologically proven carcinomas without markers were false-negative results. The dependence of the CAD markers placement upon the different carcinoma histologies was studied using the Chi-square test. Results: no significant difference could be proven for the detectability of malignant breast lesions of different histologic types. For the detectability of ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC), lobular carcinoma in situ (LCIS), tubular carcinoma and ductulo-lobular carcinoma, the true positives were 71.1%, 75%, 70.7%, 70%, 60% and 80%, respectively, in the MLO projection and 83.9%, 75.9%, 81.8%, 77.8%, 87.5% and 33.3%, respectively, in the CC projection. There was an average of 0.5 false-positive markers per mammographic image. Conclusion: The histologic type of carcinoma seems to have no influence on detectability when using the CAD system. The high rate of false-positive markers shows, however, the limited specificity of the CAD system and that improvements are necessary. (orig.)

  5. Integration of computer-aided diagnosis/detection (CAD) results in a PACS environment using CAD-PACS toolkit and DICOM SR

    International Nuclear Information System (INIS)

    Le, Anh H.T.; Liu, Brent; Huang, H.K.

    2009-01-01

    Picture Archiving and Communication System (PACS) is a mature technology in health care delivery for daily clinical imaging service and data management. Computer-aided detection and diagnosis (CAD) utilizes computer methods to obtain quantitative measurements from medical images and clinical information to assist clinicians to assess a patient's clinical state more objectively. CAD needs image input and related information from PACS to improve its accuracy; and PACS benefits from CAD results online and available at the PACS workstation as a second reader to assist physicians in the decision making process. Currently, these two technologies remain as two separate independent systems with only minimal system integration. This paper describes a universal method to integrate CAD results with PACS in its daily clinical environment. The method is based on Health Level 7 (HL7) and Digital imaging and communications in medicine (DICOM) standards, and Integrating the Healthcare Enterprise (IHE) workflow profiles. In addition, the integration method is Health Insurance Portability and Accountability Act (HIPAA) compliant. The paper presents (1) the clinical value and advantages of integrating CAD results in a PACS environment, (2) DICOM Structured Reporting formats and some important IHE workflow profiles utilized in the system integration, (3) the methodology using the CAD-PACS integration toolkit, and (4) clinical examples with step-by-step workflows of this integration. (orig.)

  6. Computer aided system engineering for space construction

    Science.gov (United States)

    Racheli, Ugo

    1989-01-01

    This viewgraph presentation covers the following topics. Construction activities envisioned for the assembly of large platforms in space (as well as interplanetary spacecraft and bases on extraterrestrial surfaces) require computational tools that exceed the capability of conventional construction management programs. The Center for Space Construction is investigating the requirements for new computational tools and, at the same time, suggesting the expansion of graduate and undergraduate curricula to include proficiency in Computer Aided Engineering (CAE) though design courses and individual or team projects in advanced space systems design. In the center's research, special emphasis is placed on problems of constructability and of the interruptability of planned activity sequences to be carried out by crews operating under hostile environmental conditions. The departure point for the planned work is the acquisition of the MCAE I-DEAS software, developed by the Structural Dynamics Research Corporation (SDRC), and its expansion to the level of capability denoted by the acronym IDEAS**2 currently used for configuration maintenance on Space Station Freedom. In addition to improving proficiency in the use of I-DEAS and IDEAS**2, it is contemplated that new software modules will be developed to expand the architecture of IDEAS**2. Such modules will deal with those analyses that require the integration of a space platform's configuration with a breakdown of planned construction activities and with a failure modes analysis to support computer aided system engineering (CASE) applied to space construction.

  7. Use of computer-aided x-ray diagnosis in oncology. [60 refs

    Energy Technology Data Exchange (ETDEWEB)

    Rotte, K H [Forschungsinstitut fuer Lungenkrankheiten und Tuberkulose, Berlin-Buch (German Democratic Republic)

    1979-01-01

    The introduction of computer-aided diagnostic reveals new perspectives for diagnostic decisions. The results of the hitherto used mathematical diagnostic models are represented. The Bayes's theorem as the most used model exhibited very different, in part unsatisfactory results. More convenient seem to be multivariate models, like discriminant analysis. Hitherto the computer-aided diagnosis was used in a relative small number of problems concerning differential diagnosis. It is necessary to compare the efficiency of the different mathematical-statistical methods.

  8. Single photon emission computed tomography in AIDS dementia complex

    International Nuclear Information System (INIS)

    Pohl, P.; Vogl, G.; Fill, H.; Roessler, H.Z.; Zangerle, R.; Gerstenbrand, F.

    1988-01-01

    Single photon emission computed tomography (SPECT) studies were performed in AIDS dementia complex using IMP in 12 patients (and HM-PAO in four of these same patients). In all patients, SPECT revealed either multiple or focal uptake defects, the latter corresponding with focal signs or symptoms in all but one case. Computerized tomography showed a diffuse cerebral atrophy in eight of 12 patients, magnetic resonance imaging exhibited changes like atrophy and/or leukoencephalopathy in two of five cases. Our data indicate that both disturbance of cerebral amine metabolism and alteration of local perfusion share in the pathogenesis of AIDS dementia complex. SPECT is an important aid in the diagnosis of AIDS dementia complex and contributes to the understanding of the pathophysiological mechanisms of this disorder

  9. Computer aided diagnosis of diabetic peripheral neuropathy

    Science.gov (United States)

    Chekh, Viktor; Soliz, Peter; McGrew, Elizabeth; Barriga, Simon; Burge, Mark; Luan, Shuang

    2014-03-01

    Diabetic peripheral neuropathy (DPN) refers to the nerve damage that can occur in diabetes patients. It most often affects the extremities, such as the feet, and can lead to peripheral vascular disease, deformity, infection, ulceration, and even amputation. The key to managing diabetic foot is prevention and early detection. Unfortunately, current existing diagnostic techniques are mostly based on patient sensations and exhibit significant inter- and intra-observer differences. We have developed a computer aided diagnostic (CAD) system for diabetic peripheral neuropathy. The thermal response of the feet of diabetic patients following cold stimulus is captured using an infrared camera. The plantar foot in the images from a thermal video are segmented and registered for tracking points or specific regions. The temperature recovery of each point on the plantar foot is extracted using our bio-thermal model and analyzed. The regions that exhibit abnormal ability to recover are automatically identified to aid the physicians to recognize problematic areas. The key to our CAD system is the segmentation of infrared video. The main challenges for segmenting infrared video compared to normal digital video are (1) as the foot warms up, it also warms up the surrounding, creating an ever changing contrast; and (2) there may be significant motion during imaging. To overcome this, a hybrid segmentation algorithm was developed based on a number of techniques such as continuous max-flow, model based segmentation, shape preservation, convex hull, and temperature normalization. Verifications of the automatic segmentation and registration using manual segmentation and markers show good agreement.

  10. Speech-enabled Computer-aided Translation

    DEFF Research Database (Denmark)

    Mesa-Lao, Bartolomé

    2014-01-01

    The present study has surveyed post-editor trainees’ views and attitudes before and after the introduction of speech technology as a front end to a computer-aided translation workbench. The aim of the survey was (i) to identify attitudes and perceptions among post-editor trainees before performing...... a post-editing task using automatic speech recognition (ASR); and (ii) to assess the degree to which post-editors’ attitudes and expectations to the use of speech technology changed after actually using it. The survey was based on two questionnaires: the first one administered before the participants...

  11. Computer-assisted diagnosis: applications in chest and breast X-ray

    International Nuclear Information System (INIS)

    Garcia, P.; Souto, M.; Correa, J.; Carrascal, F.; Mendez, A.; Martin Carreira, J.; Lado, J.M.; Vidal, J.J.

    1996-01-01

    Progress in the area of computers during the last years has focussed attention on its potential benefits as applied to computer aided diagnosis (CAD) in radiology. these CAD systems are being dedicated mainly to chest and breast radiology. Different schemes have been under investigation at our laboratory. Both automatic discrimination between normal and abnormal interstitial patterns by fractal dimension analysis and measurement of total lung capacity (TLC) have shown encouraging results (r=0.967, p<0.001). Automatic classification of mammograms in patterns with different risk to develop breast carcinoma and computer detection of breast masses with a sensitivity of 65% for a total number of 2.6 false positives per image suggest that CAD is a realistic goal in selected areas. (Author) 42 refs

  12. The University of Michigan's Computer-Aided Engineering Network.

    Science.gov (United States)

    Atkins, D. E.; Olsen, Leslie A.

    1986-01-01

    Presents an overview of the Computer-Aided Engineering Network (CAEN) of the University of Michigan. Describes its arrangement of workstations, communication networks, and servers. Outlines the factors considered in hardware and software decision making. Reviews the program's impact on students. (ML)

  13. Computer-Aided Sensor Development Focused on Security Issues

    Directory of Open Access Journals (Sweden)

    Andrzej Bialas

    2016-05-01

    Full Text Available The paper examines intelligent sensor and sensor system development according to the Common Criteria methodology, which is the basic security assurance methodology for IT products and systems. The paper presents how the development process can be supported by software tools, design patterns and knowledge engineering. The automation of this process brings cost-, quality-, and time-related advantages, because the most difficult and most laborious activities are software-supported and the design reusability is growing. The paper includes a short introduction to the Common Criteria methodology and its sensor-related applications. In the experimental section the computer-supported and patterns-based IT security development process is presented using the example of an intelligent methane detection sensor. This process is supported by an ontology-based tool for security modeling and analyses. The verified and justified models are transferred straight to the security target specification representing security requirements for the IT product. The novelty of the paper is to provide a patterns-based and computer-aided methodology for the sensors development with a view to achieving their IT security assurance. The paper summarizes the validation experiment focused on this methodology adapted for the sensors system development, and presents directions of future research.

  14. Computer-aided assessment in statistics: the CAMPUS project

    Directory of Open Access Journals (Sweden)

    Neville Hunt

    1998-12-01

    Full Text Available The relentless drive for 'efficiency' in higher education, and the consequent increase in workloads, has given university teachers a compelling incentive to investigate alternative forms of assessment. Some forms of assessment with a clear educational value can no longer be entertained because of the burden placed on the teacher. An added concern is plagiarism, which anecdotal evidence would suggest is on the increase yet which is difficult to detect in large modules with more than one assessor. While computer-aided assessment (CAA has an enthusiastic following, it is not clear to many teachers that it either reduces workloads or reduces the risk of cheating. In an ideal world, most teachers would prefer to give individual attention and personal feedback to each student when marking their work. In this sense CAA must be seen as second best and will therefore be used only if it is seen to offer significant benefits in terms of reduced workloads or increased validity.

  15. Can breast MRI computer-aided detection (CAD) improve radiologist accuracy for lesions detected at MRI screening and recommended for biopsy in a high-risk population?

    International Nuclear Information System (INIS)

    Arazi-Kleinman, T.; Causer, P.A.; Jong, R.A.; Hill, K.; Warner, E.

    2009-01-01

    Aim: To evaluate the sensitivity and specificity of magnetic resonance imaging (MRI) computer-aided detection (CAD) for breast MRI screen-detected lesions recommended for biopsy in a high-risk population. Material and methods: Fifty-six consecutive Breast Imaging Reporting and Data System (BI-RADS) 3-5 lesions with histopathological correlation [nine invasive cancers, 13 ductal carcinoma in situ (DCIS) and 34 benign] were retrospectively evaluated using a breast MRI CAD prototype (CAD-Gaea). CAD evaluation was performed separately and in consensus by two radiologists specializing in breast imaging, blinded to the histopathology. Thresholds of 50, 80, and 100% and delayed enhancement were independently assessed with CAD. Lesions were rated as malignant or benign according to threshold and delayed enhancement only and in combination. Sensitivities, specificities, and negative predictive values (NPV) were determined for CAD assessments versus pathology. Initial MRI BI-RADS interpretation without CAD versus CAD assessments were compared using paired binary diagnostic tests. Results: Threshold levels for lesion enhancement were: 50% to include all malignant (and all benign) lesions; and 100% for all invasive cancer and high-grade DCIS. Combined use of threshold and enhancement patterns for CAD assessment was best (73% sensitivity, 56% specificity and 76% NPV for all cancer). Sensitivities and NPV were better for invasive cancer (100%/100%) than for all malignancies (54%/76%). Radiologists' MRI interpretation was more sensitive than CAD (p = 0.05), but less specific (p = 0.001) for cancer detection. Conclusion: The breast MRI CAD system used could not improve the radiologists' accuracy for distinguishing all malignant from benign lesions, due to the poor sensitivity for DCIS detection.

  16. Computer-Aided Prototyping Systems (CAPS) within the software acquisition process: a case study

    OpenAIRE

    Ellis, Mary Kay

    1993-01-01

    Approved for public release; distribution is unlimited This thesis provides a case study which examines the benefits derived from the practice of computer-aided prototyping within the software acquisition process. An experimental prototyping systems currently in research is the Computer Aided Prototyping System (CAPS) managed under the Computer Science department of the Naval Postgraduate School, Monterey, California. This thesis determines the qualitative value which may be realized by ...

  17. Integration of Fault Detection and Isolation with Control Using Neuro-fuzzy Scheme

    Directory of Open Access Journals (Sweden)

    A. Asokan

    2009-10-01

    Full Text Available In this paper an algorithms is developed for fault diagnosis and fault tolerant control strategy for nonlinear systems subjected to an unknown time-varying fault. At first, the design of fault diagnosis scheme is performed using model based fault detection technique. The neuro-fuzzy chi-square scheme is applied for fault detection and isolation. The fault magnitude and time of occurrence of fault is obtained through neuro-fuzzy chi-square scheme. The estimated magnitude of the fault magnitude is normalized and used by the feed-forward control algorithm to make appropriate changes in the manipulated variable to keep the controlled variable near its set value. The feed-forward controller acts along with feed-back controller to control the multivariable system. The performance of the proposed scheme is applied to a three- tank process for various types of fault inputs to show the effectiveness of the proposed approach.

  18. Computer-aided diagnosis of liver tumors on computed tomography images.

    Science.gov (United States)

    Chang, Chin-Chen; Chen, Hong-Hao; Chang, Yeun-Chung; Yang, Ming-Yang; Lo, Chung-Ming; Ko, Wei-Chun; Lee, Yee-Fan; Liu, Kao-Lang; Chang, Ruey-Feng

    2017-07-01

    Liver cancer is the tenth most common cancer in the USA, and its incidence has been increasing for several decades. Early detection, diagnosis, and treatment of the disease are very important. Computed tomography (CT) is one of the most common and robust imaging techniques for the detection of liver cancer. CT scanners can provide multiple-phase sequential scans of the whole liver. In this study, we proposed a computer-aided diagnosis (CAD) system to diagnose liver cancer using the features of tumors obtained from multiphase CT images. A total of 71 histologically-proven liver tumors including 49 benign and 22 malignant lesions were evaluated with the proposed CAD system to evaluate its performance. Tumors were identified by the user and then segmented using a region growing algorithm. After tumor segmentation, three kinds of features were obtained for each tumor, including texture, shape, and kinetic curve. The texture was quantified using 3 dimensional (3-D) texture data of the tumor based on the grey level co-occurrence matrix (GLCM). Compactness, margin, and an elliptic model were used to describe the 3-D shape of the tumor. The kinetic curve was established from each phase of tumor and represented as variations in density between each phase. Backward elimination was used to select the best combination of features, and binary logistic regression analysis was used to classify the tumors with leave-one-out cross validation. The accuracy and sensitivity for the texture were 71.82% and 68.18%, respectively, which were better than for the shape and kinetic curve under closed specificity. Combining all of the features achieved the highest accuracy (58/71, 81.69%), sensitivity (18/22, 81.82%), and specificity (40/49, 81.63%). The Az value of combining all features was 0.8713. Combining texture, shape, and kinetic curve features may be able to differentiate benign from malignant tumors in the liver using our proposed CAD system. Copyright © 2017 Elsevier B.V. All

  19. Multi-stage identification scheme for detecting damage in structures under ambient excitations

    International Nuclear Information System (INIS)

    Bao, Chunxiao; Li, Zhong-Xian; Hao, Hong

    2013-01-01

    Structural damage identification methods are critical to the successful application of structural health monitoring (SHM) systems to civil engineering structures. The dynamic response of civil engineering structures is usually characterized by high nonlinearity and non-stationarity. Accordingly, an improved Hilbert–Huang transform (HHT) method which is adaptive, output-only and applicable to system identification of in-service structures under ambient excitations is developed in this study. Based on this method, a multi-stage damage detection scheme including the detection of damage occurrence, damage existence, damage location and the estimation of damage severity is developed. In this scheme, the improved HHT method is used to analyse the structural acceleration response, the obtained instantaneous frequency detects the instant of damage occurrence, the instantaneous phase is sensitive to minor damage and provides reliable damage indication, and the damage indicator developed based on statistical analysis of the Hilbert marginal spectrum detects damage locations. Finally, the response sampled at the detected damage location is continuously analysed to estimate the damage severity. Numerical and experimental studies of frame structures under ambient excitations are performed. The results demonstrate that this scheme accomplishes the above damage detection functions within one flow. It is robust, time efficient, simply implemented and applicable to the real-time SHM of in-service structures. (paper)

  20. Custom-Made Computer-Aided-Design/Computer-Aided-Manufacturing Biphasic Calcium-Phosphate Scaffold for Augmentation of an Atrophic Mandibular Anterior Ridge

    Directory of Open Access Journals (Sweden)

    Francesco Guido Mangano

    2015-01-01

    Full Text Available This report documents the clinical, radiographic, and histologic outcome of a custom-made computer-aided-design/computer-aided-manufactured (CAD/CAM scaffold used for the alveolar ridge augmentation of a severely atrophic anterior mandible. Computed tomographic (CT images of an atrophic anterior mandible were acquired and modified into a 3-dimensional (3D reconstruction model; this was transferred to a CAD program, where a custom-made scaffold was designed. CAM software generated a set of tool-paths for the manufacture of the scaffold on a computer-numerical-control milling machine into the exact shape of the 3D design. A custom-made scaffold was milled from a synthetic micromacroporous biphasic calcium phosphate (BCP block. The scaffold closely matched the shape of the defect: this helped to reduce the time for the surgery and contributed to good healing. One year later, newly formed and well-integrated bone was clinically available, and two implants (AnyRidge, MegaGen, Gyeongbuk, South Korea were placed. The histologic samples retrieved from the implant sites revealed compact mature bone undergoing remodelling, marrow spaces, and newly formed trabecular bone surrounded by residual BCP particles. This study demonstrates that custom-made scaffolds can be fabricated by combining CT scans and CAD/CAM techniques. Further studies on a larger sample of patients are needed to confirm these results.

  1. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and

  2. Teaching advance care planning to medical students with a computer-based decision aid.

    Science.gov (United States)

    Green, Michael J; Levi, Benjamin H

    2011-03-01

    Discussing end-of-life decisions with cancer patients is a crucial skill for physicians. This article reports findings from a pilot study evaluating the effectiveness of a computer-based decision aid for teaching medical students about advance care planning. Second-year medical students at a single medical school were randomized to use a standard advance directive or a computer-based decision aid to help patients with advance care planning. Students' knowledge, skills, and satisfaction were measured by self-report; their performance was rated by patients. 121/133 (91%) of students participated. The Decision-Aid Group (n = 60) outperformed the Standard Group (n = 61) in terms of students' knowledge (p satisfaction with their learning experience (p student performance. Use of a computer-based decision aid may be an effective way to teach medical students how to discuss advance care planning with cancer patients.

  3. Development of the computer-aided process planning (CAPP system for polymer injection molds manufacturing

    Directory of Open Access Journals (Sweden)

    J. Tepić

    2011-10-01

    Full Text Available Beginning of production and selling of polymer products largely depends on mold manufacturing. The costs of mold manufacturing have significant share in the final price of a product. The best way to improve and rationalize polymer injection molds production process is by doing mold design automation and manufacturing process planning automation. This paper reviews development of a dedicated process planning system for manufacturing of the mold for injection molding, which integrates computer-aided design (CAD, computer-aided process planning (CAPP and computer-aided manufacturing (CAM technologies.

  4. Deep learning aided decision support for pulmonary nodules diagnosing: a review.

    Science.gov (United States)

    Yang, Yixin; Feng, Xiaoyi; Chi, Wenhao; Li, Zhengyang; Duan, Wenzhe; Liu, Haiping; Liang, Wenhua; Wang, Wei; Chen, Ping; He, Jianxing; Liu, Bo

    2018-04-01

    Deep learning techniques have recently emerged as promising decision supporting approaches to automatically analyze medical images for different clinical diagnosing purposes. Diagnosing of pulmonary nodules by using computer-assisted diagnosing has received considerable theoretical, computational, and empirical research work, and considerable methods have been developed for detection and classification of pulmonary nodules on different formats of images including chest radiographs, computed tomography (CT), and positron emission tomography in the past five decades. The recent remarkable and significant progress in deep learning for pulmonary nodules achieved in both academia and the industry has demonstrated that deep learning techniques seem to be promising alternative decision support schemes to effectively tackle the central issues in pulmonary nodules diagnosing, including feature extraction, nodule detection, false-positive reduction, and benign-malignant classification for the huge volume of chest scan data. The main goal of this investigation is to provide a comprehensive state-of-the-art review of the deep learning aided decision support for pulmonary nodules diagnosing. As far as the authors know, this is the first time that a review is devoted exclusively to deep learning techniques for pulmonary nodules diagnosing.

  5. Computer-aided engineering for Qinshan CANDU projects

    International Nuclear Information System (INIS)

    Huang Zhizhang; Goland, D.

    1999-01-01

    The author briefly describes AECL's work in applying computer-aided engineering tools to the Qinshan CANDU Project. The main emphases will be to introduce the major CADD software tools and their use in civil design, process design and EI and C design. Other special software tools and non-CADD tools and their applications are also briefly introduced

  6. Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers

    International Nuclear Information System (INIS)

    Szucs-Farkas, Zsolt; Patak, Michael A.; Yuksel-Hatz, Seyran; Ruder, Thomas; Vock, Peter

    2010-01-01

    To retrospectively analyze the performance of a commercial computer-aided diagnosis (CAD) software in the detection of pulmonary nodules in original and energy-subtracted (ES) chest radiographs. Original and ES chest radiographs of 58 patients with 105 pulmonary nodules measuring 5-30 mm and images of 25 control subjects with no nodules were randomized. Five blinded readers evaluated firstly the original postero-anterior images alone and then together with the subtracted radiographs. In a second phase, original and ES images were analyzed by a commercial CAD program. CT was used as reference standard. CAD results were compared to the readers' findings. True-positive (TP) and false-positive (FP) findings with CAD on subtracted and non-subtracted images were compared. Depending on the reader's experience, CAD detected between 11 and 21 nodules missed by readers. Human observers found three to 16 lesions missed by the CAD software. CAD used with ES images produced significantly fewer FPs than with non-subtracted images: 1.75 and 2.14 FPs per image, respectively (p=0.029). The difference for the TP nodules was not significant (40 nodules on ES images and 34 lesions in non-subtracted radiographs, p = 0.142). CAD can improve lesion detection both on energy subtracted and non-subtracted chest images, especially for less experienced readers. The CAD program marked less FPs on energy-subtracted images than on original chest radiographs. (orig.)

  7. Maxillary first molars with six canals confirmed with the aid of cone-beam computed tomography

    Directory of Open Access Journals (Sweden)

    Tahra Mohammad Al-Habboubi

    2016-01-01

    Full Text Available The maxillary first molar exhibits unpredictable root canal morphology. Different number of root canals has been reported with the aids of new tools. It is very important to clinically detect all canals for better outcome results. The purpose of the present case is to present a case of the maxillary first molar in a Saudi male patient with an anatomical variation of having six root canals that were confirmed with cone-beam computed tomography.

  8. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    Science.gov (United States)

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  9. Computer aided molecular design with combined molecular modeling and group contribution

    DEFF Research Database (Denmark)

    Harper, Peter Mathias; Gani, Rafiqul; Kolar, Petr

    1999-01-01

    Computer-aided molecular design (CAMD) provides a means for determining molecules or mixtures of molecules (CAMMD) having a desirable set of physicochemical properties. The application range of CAMD is restricted due to limitations on the complexity of the generated molecular structures and on th......Computer-aided molecular design (CAMD) provides a means for determining molecules or mixtures of molecules (CAMMD) having a desirable set of physicochemical properties. The application range of CAMD is restricted due to limitations on the complexity of the generated molecular structures...

  10. A light weight secure image encryption scheme based on chaos & DNA computing

    Directory of Open Access Journals (Sweden)

    Bhaskar Mondal

    2017-10-01

    Full Text Available This paper proposed a new light weight secure cryptographic scheme for secure image communication. In this scheme the plain image is permuted first using a sequence of pseudo random number (PRN and encrypted by DeoxyriboNucleic Acid (DNA computation. Two PRN sequences are generated by a Pseudo Random Number Generator (PRNG based on cross coupled chaotic logistic map using two sets of keys. The first PRN sequence is used for permuting the plain image whereas the second PRN sequence is used for generating random DNA sequence. The number of rounds of permutation and encryption may be variable to increase security. The scheme is proposed for gray label images but the scheme may be extended for color images and text data. Simulation results exhibit that the proposed scheme can defy any kind of attack.

  11. A Novel Scheme for DVL-Aided SINS In-Motion Alignment Using UKF Techniques

    Directory of Open Access Journals (Sweden)

    Wenqi Wu

    2013-01-01

    Full Text Available In-motion alignment of Strapdown Inertial Navigation Systems (SINS without any geodetic-frame observations is one of the toughest challenges for Autonomous Underwater Vehicles (AUV. This paper presents a novel scheme for Doppler Velocity Log (DVL aided SINS alignment using Unscented Kalman Filter (UKF which allows large initial misalignments. With the proposed mechanism, a nonlinear SINS error model is presented and the measurement model is derived under the assumption that large misalignments may exist. Since a priori knowledge of the measurement noise covariance is of great importance to robustness of the UKF, the covariance-matching methods widely used in the Adaptive KF (AKF are extended for use in Adaptive UKF (AUKF. Experimental results show that the proposed DVL-aided alignment model is effective with any initial heading errors. The performances of the adaptive filtering methods are evaluated with regards to their parameter estimation stability. Furthermore, it is clearly shown that the measurement noise covariance can be estimated reliably by the adaptive UKF methods and hence improve the performance of the alignment.

  12. Computer-Aided Multiscale Modelling for Chemical Process Engineering

    DEFF Research Database (Denmark)

    Morales Rodriguez, Ricardo; Gani, Rafiqul

    2007-01-01

    Chemical processes are generally modeled through monoscale approaches, which, while not adequate, satisfy a useful role in product-process design. In this case, use of a multi-dimensional and multi-scale model-based approach has importance in product-process development. A computer-aided framework...

  13. Cooperation schemes for rate enhancement in detect-and-forward relay channels

    KAUST Repository

    Benjillali, Mustapha

    2010-05-01

    To improve the spectral efficiency of "Detect-and-Forward" (DetF) half-duplex relaying in fading channels, we propose a cooperation scheme where the relay uses a modulation whose order is higher than the one at the source. In a new common framework, we show that the proposed scheme offers considerable gains - in terms of achievable information rates - compared to the conventional DetF relaying schemes for both orthogonal and non-orthogonal source/relay cooperation. This allows us to propose an adaptive cooperation scheme based on the maximization of the information rate at the destination which needs to observe only the average signal-to-noise ratios of direct and relaying links. ©2010 IEEE.

  14. The use of the MacCormack scheme in computational hydraulics

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, R. [Universidad Central de Venezuela, Inst. de Mecanica de Fluidos, Caracas (Venezuela); Zhang, H.; Kahawita, R. [Ecole Polytechnique, Dept. of Civil Engineering, Montreal, Quebec (Canada)

    1985-07-01

    This manuscript describes the development of a numerical model that solves shallow water problems based upon an enhanced version of the MacCormack explicit scheme (MS). The MS has been successfully applied to solve numerous problems in gas dynamics. However, the standard application of the MS to solve the shallow water equations can cause in certain test cases non-linear instabilities and non-symmetrical results that eventually destroy the solution. By examining the calculation 'cell' one can show that the MS is not symmetric in space, which explains why it cannot be used directly in the treatment of hydraulic problems most of which possess irregular boundaries thereby resulting in a flow with no 'preferred direction'. This is contrary to what is usually encountered in aerodynamics. The enhanced MacCormack scheme is obtained by a simple modification to the original formulation resulting in a symmetric scheme. The scheme has been applied to the computation of the flowfield in a real life situation with satisfactory results. (author)

  15. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system

    Science.gov (United States)

    das Neves, Flávio Domingues; de Almeida Prado Naves Carneiro, Thiago; do Prado, Célio Jesus; Prudente, Marcel Santana; Zancopé, Karla; Davi, Letícia Resende; Mendonça, Gustavo; Soares, Carlos José

    2014-08-01

    The current study evaluated prosthetic dental crowns obtained by optical scanning and a computer-aided designing/computer-aided manufacturing system using micro-computed tomography to compare the marginal fit. The virtual models were obtained with four different scanning surfaces: typodont (T), regular impressions (RI), master casts (MC), and powdered master casts (PMC). Five virtual models were obtained for each group. For each model, a crown was designed on the software and milled from feldspathic ceramic blocks. Micro-CT images were obtained for marginal gap measurements and the data were statistically analyzed by one-way analysis of variance followed by Tukey's test. The mean vertical misfit was T=62.6±65.2 μm; MC=60.4±38.4 μm; PMC=58.1±38.0 μm, and RI=89.8±62.8 μm. Considering a percentage of vertical marginal gap of up to 75 μm, the results were T=71.5%, RI=49.2%, MC=69.6%, and PMC=71.2%. The percentages of horizontal overextension were T=8.5%, RI=0%, MC=0.8%, and PMC=3.8%. Based on the results, virtual model acquisition by scanning the typodont (simulated mouth) or MC, with or without powder, showed acceptable values for the marginal gap. The higher result of marginal gap of the RI group suggests that it is preferable to scan this directly from the mouth or from MC.

  16. Computer-aided detection system for chest radiography: reducing report turnaround times of examinations with abnormalities.

    Science.gov (United States)

    Kao, E-Fong; Liu, Gin-Chung; Lee, Lo-Yeh; Tsai, Huei-Yi; Jaw, Twei-Shiun

    2015-06-01

    The ability to give high priority to examinations with pathological findings could be very useful to radiologists with large work lists who wish to first evaluate the most critical studies. A computer-aided detection (CAD) system for identifying chest examinations with abnormalities has therefore been developed. To evaluate the effectiveness of a CAD system on report turnaround times of chest examinations with abnormalities. The CAD system was designed to automatically mark chest examinations with possible abnormalities in the work list of radiologists interpreting chest examinations. The system evaluation was performed in two phases: two radiologists interpreted the chest examinations without CAD in phase 1 and with CAD in phase 2. The time information recorded by the radiology information system was then used to calculate the turnaround times. All chest examinations were reviewed by two other radiologists and were divided into normal and abnormal groups. The turnaround times for the examinations with pathological findings with and without the CAD system assistance were compared. The sensitivity and specificity of the CAD for chest abnormalities were 0.790 and 0.697, respectively, and use of the CAD system decreased the turnaround time for chest examinations with abnormalities by 44%. The turnaround times required for radiologists to identify chest examinations with abnormalities could be reduced by using the CAD system. This system could be useful for radiologists with large work lists who wish to first evaluate the most critical studies. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  17. A computer-aided diagnosis system to detect pathologies in temporal subtraction images of chest radiographs

    Science.gov (United States)

    Looper, Jared; Harrison, Melanie; Armato, Samuel G.

    2016-03-01

    Radiologists often compare sequential radiographs to identify areas of pathologic change; however, this process is prone to error, as human anatomy can obscure the regions of change, causing the radiologists to overlook pathology. Temporal subtraction (TS) images can provide enhanced visualization of regions of change in sequential radiographs and allow radiologists to better detect areas of change in radiographs. Not all areas of change shown in TS images, however, are actual pathology. The purpose of this study was to create a computer-aided diagnostic (CAD) system that identifies which regions of change are caused by pathology and which are caused by misregistration of the radiographs used to create the TS image. The dataset used in this study contained 120 images with 74 pathologic regions on 54 images outlined by an experienced radiologist. High and low ("light" and "dark") gray-level candidate regions were extracted from the images using gray-level thresholding. Then, sampling techniques were used to address the class imbalance problem between "true" and "false" candidate regions. Next, the datasets of light candidate regions, dark candidate regions, and the combined set of light and dark candidate regions were used as training and testing data for classifiers by using five-fold cross validation. Of the classifiers tested (support vector machines, discriminant analyses, logistic regression, and k-nearest neighbors), the support vector machine on the combined candidates using synthetic minority oversampling technique (SMOTE) performed best with an area under the receiver operating characteristic curve value of 0.85, a sensitivity of 85%, and a specificity of 84%.

  18. The potential impact of computer-aided assessment technology in ...

    African Journals Online (AJOL)

    The potential impact of computer-aided assessment technology in higher education. ... Further more 'Increased number of students in Higher Education and the ... benefits, limitations, impacts on student learning and strategies for developing ...

  19. Computer-aided control system design

    International Nuclear Information System (INIS)

    Lebenhaft, J.R.

    1986-01-01

    Control systems are typically implemented using conventional PID controllers, which are then tuned manually during plant commissioning to compensate for interactions between feedback loops. As plants increase in size and complexity, such controllers can fail to provide adequate process regulations. Multivariable methods can be utilized to overcome these limitations. At the Chalk River Nuclear Laboratories, modern control systems are designed and analyzed with the aid of MVPACK, a system of computer programs that appears to the user like a high-level calculator. The software package solves complicated control problems, and provides useful insight into the dynamic response and stability of multivariable systems

  20. Computer-aided dispatching system design specification

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, M.G.

    1997-12-16

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol Operations Center. This document reflects the as-built requirements for the system that was delivered by GTE Northwest, Inc. This system provided a commercial off-the-shelf computer-aided dispatching system and alarm monitoring system currently in operations at the Hanford Patrol Operations Center, Building 2721E. This system also provides alarm back-up capability for the Plutonium Finishing Plant (PFP).

  1. Computer-aided dispatching system design specification

    International Nuclear Information System (INIS)

    Briggs, M.G.

    1997-01-01

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol Operations Center. This document reflects the as-built requirements for the system that was delivered by GTE Northwest, Inc. This system provided a commercial off-the-shelf computer-aided dispatching system and alarm monitoring system currently in operations at the Hanford Patrol Operations Center, Building 2721E. This system also provides alarm back-up capability for the Plutonium Finishing Plant (PFP)

  2. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  3. DETECTION OF MICROCALCIFICATION IN DIGITAL MAMMOGRAMS USING ONE DIMENSIONAL WAVELET TRANSFORM

    Directory of Open Access Journals (Sweden)

    T. Balakumaran

    2010-11-01

    Full Text Available Mammography is the most efficient method for breast cancer early detection. Clusters of microcalcifications are the early sign of breast cancer and their detection is the key to improve prognosis of breast cancer. Microcalcifications appear in mammogram image as tiny localized granular points, which is often difficult to detect by naked eye because of their small size. Automatic and accurately detection of microcalcifications has received much more attention from radiologists and physician. An efficient method for automatic detection of clustered microcalcifications in digitized mammograms is the use of Computer Aided Diagnosis (CAD systems. This paper presents a one dimensional wavelet-based multiscale products scheme for microcalcification detection in mammogram images. The detection of microcalcifications were achieved by decomposing the each line of mammograms by 1D wavelet transform into different frequency sub-bands, suppressing the low-frequency subband, and finally reconstructing the mammogram from the subbands containing only significant high frequencies features. The significant features are obtained by multiscale products. Preliminary results indicate that the proposed scheme is better in suppressing the background and detecting the microcalcification clusters than any other wavelet decomposition methods.

  4. A new 2D segmentation method based on dynamic programming applied to computer aided detection in mammography

    International Nuclear Information System (INIS)

    Timp, Sheila; Karssemeijer, Nico

    2004-01-01

    Mass segmentation plays a crucial role in computer-aided diagnosis (CAD) systems for classification of suspicious regions as normal, benign, or malignant. In this article we present a robust and automated segmentation technique--based on dynamic programming--to segment mass lesions from surrounding tissue. In addition, we propose an efficient algorithm to guarantee resulting contours to be closed. The segmentation method based on dynamic programming was quantitatively compared with two other automated segmentation methods (region growing and the discrete contour model) on a dataset of 1210 masses. For each mass an overlap criterion was calculated to determine the similarity with manual segmentation. The mean overlap percentage for dynamic programming was 0.69, for the other two methods 0.60 and 0.59, respectively. The difference in overlap percentage was statistically significant. To study the influence of the segmentation method on the performance of a CAD system two additional experiments were carried out. The first experiment studied the detection performance of the CAD system for the different segmentation methods. Free-response receiver operating characteristics analysis showed that the detection performance was nearly identical for the three segmentation methods. In the second experiment the ability of the classifier to discriminate between malignant and benign lesions was studied. For region based evaluation the area A z under the receiver operating characteristics curve was 0.74 for dynamic programming, 0.72 for the discrete contour model, and 0.67 for region growing. The difference in A z values obtained by the dynamic programming method and region growing was statistically significant. The differences between other methods were not significant

  5. An automated computer misuse detection system for UNICOS

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, K.A.; Neuman, M.C.; Simmonds, D.D.; Stallings, C.A.; Thompson, J.L.; Christoph, G.G.

    1994-09-27

    An effective method for detecting computer misuse is the automatic monitoring and analysis of on-line user activity. This activity is reflected in the system audit record, in the system vulnerability posture, and in other evidence found through active testing of the system. During the last several years we have implemented an automatic misuse detection system at Los Alamos. This is the Network Anomaly Detection and Intrusion Reporter (NADIR). We are currently expanding NADIR to include processing of the Cray UNICOS operating system. This new component is called the UNICOS Realtime NADIR, or UNICORN. UNICORN summarizes user activity and system configuration in statistical profiles. It compares these profiles to expert rules that define security policy and improper or suspicious behavior. It reports suspicious behavior to security auditors and provides tools to aid in follow-up investigations. The first phase of UNICORN development is nearing completion, and will be operational in late 1994.

  6. A Novel Congestion Detection Scheme in TCP Over OBS Networks

    KAUST Repository

    Shihada, Basem; Ho, Pin-Han; Zhang, Qiong

    2009-01-01

    This paper introduces a novel congestion detection scheme for high-bandwidth TCP flows over optical burst switching (OBS) networks, called statistical additive increase multiplicative decrease (SAIMD). SAIMD maintains and analyzes a number

  7. Computer-Aided Communication Satellite System Analysis and Optimization.

    Science.gov (United States)

    Stagl, Thomas W.; And Others

    Various published computer programs for fixed/broadcast communication satellite system synthesis and optimization are discussed. The rationale for selecting General Dynamics/Convair's Satellite Telecommunication Analysis and Modeling Program (STAMP) in modified form to aid in the system costing and sensitivity analysis work in the Program on…

  8. Computer-aided diagnostics of screening mammography using content-based image retrieval

    Science.gov (United States)

    Deserno, Thomas M.; Soiron, Michael; de Oliveira, Júlia E. E.; de A. Araújo, Arnaldo

    2012-03-01

    Breast cancer is one of the main causes of death among women in occidental countries. In the last years, screening mammography has been established worldwide for early detection of breast cancer, and computer-aided diagnostics (CAD) is being developed to assist physicians reading mammograms. A promising method for CAD is content-based image retrieval (CBIR). Recently, we have developed a classification scheme of suspicious tissue pattern based on the support vector machine (SVM). In this paper, we continue moving towards automatic CAD of screening mammography. The experiments are based on in total 10,509 radiographs that have been collected from different sources. From this, 3,375 images are provided with one and 430 radiographs with more than one chain code annotation of cancerous regions. In different experiments, this data is divided into 12 and 20 classes, distinguishing between four categories of tissue density, three categories of pathology and in the 20 class problem two categories of different types of lesions. Balancing the number of images in each class yields 233 and 45 images remaining in each of the 12 and 20 classes, respectively. Using a two-dimensional principal component analysis, features are extracted from small patches of 128 x 128 pixels and classified by means of a SVM. Overall, the accuracy of the raw classification was 61.6 % and 52.1 % for the 12 and the 20 class problem, respectively. The confusion matrices are assessed for detailed analysis. Furthermore, an implementation of a SVM-based CBIR system for CADx in screening mammography is presented. In conclusion, with a smarter patch extraction, the CBIR approach might reach precision rates that are helpful for the physicians. This, however, needs more comprehensive evaluation on clinical data.

  9. A Computer-Aided FPS-Oriented Approach for Construction Briefing

    Institute of Scientific and Technical Information of China (English)

    Xiaochun Luo; Qiping Shen

    2008-01-01

    Function performance specification (FPS) is one of the value management (VM) techniques de- veloped for the explicit statement of optimum product definition. This technique is widely used in software engineering and manufacturing industry, and proved to be successful to perform product defining tasks. This paper describes an FPS-odented approach for construction briefing, which is critical to the successful deliv- ery of construction projects. Three techniques, i.e., function analysis system technique, shared space, and computer-aided toolkit, are incorporated into the proposed approach. A computer-aided toolkit is developed to facilitate the implementation of FPS in the briefing processes. This approach can facilitate systematic, ef- ficient identification, clarification, and representation of client requirements in trail running. The limitations of the approach and future research work are also discussed at the end of the paper.

  10. An Alternative Method to Compute the Bit Error Probability of Modulation Schemes Subject to Nakagami- Fading

    Directory of Open Access Journals (Sweden)

    Madeiro Francisco

    2010-01-01

    Full Text Available Abstract This paper presents an alternative method for determining exact expressions for the bit error probability (BEP of modulation schemes subject to Nakagami- fading. In this method, the Nakagami- fading channel is seen as an additive noise channel whose noise is modeled as the ratio between Gaussian and Nakagami- random variables. The method consists of using the cumulative density function of the resulting noise to obtain closed-form expressions for the BEP of modulation schemes subject to Nakagami- fading. In particular, the proposed method is used to obtain closed-form expressions for the BEP of -ary quadrature amplitude modulation ( -QAM, -ary pulse amplitude modulation ( -PAM, and rectangular quadrature amplitude modulation ( -QAM under Nakagami- fading. The main contribution of this paper is to show that this alternative method can be used to reduce the computational complexity for detecting signals in the presence of fading.

  11. Computational reduction techniques for numerical vibro-acoustic analysis of hearing aids

    DEFF Research Database (Denmark)

    Creixell Mediante, Ester

    . In this thesis, several challenges encountered in the process of modelling and optimizing hearing aids are addressed. Firstly, a strategy for modelling the contacts between plastic parts for harmonic analysis is developed. Irregularities in the contact surfaces, inherent to the manufacturing process of the parts....... Secondly, the applicability of Model Order Reduction (MOR) techniques to lower the computational complexity of hearing aid vibro-acoustic models is studied. For fine frequency response calculation and optimization, which require solving the numerical model repeatedly, a computational challenge...... is encountered due to the large number of Degrees of Freedom (DOFs) needed to represent the complexity of the hearing aid system accurately. In this context, several MOR techniques are discussed, and an adaptive reduction method for vibro-acoustic optimization problems is developed as a main contribution. Lastly...

  12. Computer-aided analysis of difference schemes for partial differential equations

    CERN Document Server

    Ganzha, Victor G

    2011-01-01

    VICTOR G. GANZHA is Visiting Professor of Mathematics with the Faculty of Mathematics and Informatics at the University of Kassel, Germany, where he presents lecture courses on advanced computer algebra systems and their applications to higher mathematics and numerical analysis. He is coauthor of Differentialgleichungen mit Mathematica. E. V. VOROZHTSOV is a research scientist at the Russian Academy of Sciences in Novosibirsk, Russia, and Professor of Mathematics with the Faculty of Flying Vehicles at the Novosibirsk State Technical University. He is coauthor of Methods for the Localization o

  13. Computer-Aided Transformation of PDE Models: Languages, Representations, and a Calculus of Operations

    Science.gov (United States)

    2016-01-05

    Computer-aided transformation of PDE models: languages, representations, and a calculus of operations A domain-specific embedded language called...languages, representations, and a calculus of operations Report Title A domain-specific embedded language called ibvp was developed to model initial...Computer-aided transformation of PDE models: languages, representations, and a calculus of operations 1 Vision and background Physical and engineered systems

  14. The Development of Computer-Aided Design for Electrical Equipment Selection and Arrangement of 10 Kv Switchgear

    Directory of Open Access Journals (Sweden)

    Chernaya Anastassiya

    2015-01-01

    Full Text Available The paper intends to give an overview of a computer-aided design program application. The research includes two main parts: the development of a computer-aided design for an appropriate switchgear selection and its arrangement in an indoor switchgear layout. Matlab program was used to develop a computer-aided design system. The use of this program considerably simplifies the selection and arrangement of 10 kV switchgear.

  15. The Effects of Computer-Aided Design Software on Engineering Students' Spatial Visualisation Skills

    Science.gov (United States)

    Kösa, Temel; Karakus, Fatih

    2018-01-01

    The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations…

  16. Virtual Reality versus Computer-Aided Exposure Treatments for Fear of Flying

    Science.gov (United States)

    Tortella-Feliu, Miquel; Botella, Cristina; Llabres, Jordi; Breton-Lopez, Juana Maria; del Amo, Antonio Riera; Banos, Rosa M.; Gelabert, Joan M.

    2011-01-01

    Evidence is growing that two modalities of computer-based exposure therapies--virtual reality and computer-aided psychotherapy--are effective in treating anxiety disorders, including fear of flying. However, they have not yet been directly compared. The aim of this study was to analyze the efficacy of three computer-based exposure treatments for…

  17. [Three-dimensional computer aided design for individualized post-and-core restoration].

    Science.gov (United States)

    Gu, Xiao-yu; Wang, Ya-ping; Wang, Yong; Lü, Pei-jun

    2009-10-01

    To develop a method of three-dimensional computer aided design (CAD) of post-and-core restoration. Two plaster casts with extracted natural teeth were used in this study. The extracted teeth were prepared and scanned using tomography method to obtain three-dimensional digitalized models. According to the basic rules of post-and-core design, posts, cores and cavity surfaces of the teeth were designed using the tools for processing point clouds, curves and surfaces on the forward engineering software of Tanglong prosthodontic system. Then three-dimensional figures of the final restorations were corrected according to the configurations of anterior teeth, premolars and molars respectively. Computer aided design of 14 post-and-core restorations were finished, and good fitness between the restoration and the three-dimensional digital models were obtained. Appropriate retention forms and enough spaces for the full crown restorations can be obtained through this method. The CAD of three-dimensional figures of the post-and-core restorations can fulfill clinical requirements. Therefore they can be used in computer-aided manufacture (CAM) of post-and-core restorations.

  18. A Computer-Aided Diagnosis System for Breast Cancer Combining Mammography and Proteomics

    Science.gov (United States)

    2007-05-01

    for sonography,” Ultrasound Med. Biol. 26, 405-411 2000. 20K. Horsch, M. L. Giger, L. A. Venta , and C. J. Vyborny, “Computerized diagnosis of breast...lesions on ultrasound,” Med. Phys. 29, 157-164 2002. 21K. Horsch, M. L. Giger, C. J. Vyborny, and L. A. Venta , “Performance of computer-aided...Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography. Acad Radiol

  19. Computerized Detection of Lung Nodules by Means of “Virtual Dual-Energy” Radiography

    Science.gov (United States)

    Chen, Sheng; Suzuki, Kenji

    2014-01-01

    Major challenges in current computer-aided detection (CADe) schemes for nodule detection in chest radiographs (CXRs) are to detect nodules that overlap with ribs and/or clavicles and to reduce the frequent false positives (FPs) caused by ribs. Detection of such nodules by a CADe scheme is very important, because radiologists are likely to miss such subtle nodules. Our purpose in this study was to develop a CADe scheme with improved sensitivity and specificity by use of “virtual dual-energy” (VDE) CXRs where ribs and clavicles are suppressed with massive-training artificial neural networks (MTANNs). To reduce rib-induced FPs and detect nodules overlapping with ribs, we incorporated the VDE technology in our CADe scheme. The VDE technology suppressed rib and clavicle opacities in CXRs while maintaining soft-tissue opacity by use of the MTANN technique that had been trained with real dual-energy imaging. Our scheme detected nodule candidates on VDE images by use of a morphologic filtering technique. Sixty morphologic and gray-level-based features were extracted from each candidate from both original and VDE CXRs. A nonlinear support vector classifier was employed for classification of the nodule candidates. A publicly available database containing 140 nodules in 140 CXRs and 93 normal CXRs was used for testing our CADe scheme. All nodules were confirmed by computed tomography examinations, and the average size of the nodules was 17.8 mm. Thirty percent (42/140) of the nodules were rated “extremely subtle” or “very subtle” by a radiologist. The original scheme without VDE technology achieved a sensitivity of 78.6% (110/140) with 5 (1165/233) FPs per image. By use of the VDE technology, more nodules overlapping with ribs or clavicles were detected and the sensitivity was improved substantially to 85.0% (119/140) at the same FP rate in a leave-one-out cross-validation test, whereas the FP rate was reduced to 2.5 (583/233) per image at the same sensitivity

  20. Costs incurred by applying computer-aided design/computer-aided manufacturing techniques for the reconstruction of maxillofacial defects.

    Science.gov (United States)

    Rustemeyer, Jan; Melenberg, Alex; Sari-Rieger, Aynur

    2014-12-01

    This study aims to evaluate the additional costs incurred by using a computer-aided design/computer-aided manufacturing (CAD/CAM) technique for reconstructing maxillofacial defects by analyzing typical cases. The medical charts of 11 consecutive patients who were subjected to the CAD/CAM technique were considered, and invoices from the companies providing the CAD/CAM devices were reviewed for every case. The number of devices used was significantly correlated with cost (r = 0.880; p costs were found between cases in which prebent reconstruction plates were used (€3346.00 ± €29.00) and cases in which they were not (€2534.22 ± €264.48; p costs of two, three and four devices, even when ignoring the cost of reconstruction plates. Additional fees provided by statutory health insurance covered a mean of 171.5% ± 25.6% of the cost of the CAD/CAM devices. Since the additional fees provide financial compensation, we believe that the CAD/CAM technique is suited for wide application and not restricted to complex cases. Where additional fees/funds are not available, the CAD/CAM technique might be unprofitable, so the decision whether or not to use it remains a case-to-case decision with respect to cost versus benefit. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. The Research of Computer Aided Farm Machinery Designing Method Based on Ergonomics

    Science.gov (United States)

    Gao, Xiyin; Li, Xinling; Song, Qiang; Zheng, Ying

    Along with agricultural economy development, the farm machinery product type Increases gradually, the ergonomics question is also getting more and more prominent. The widespread application of computer aided machinery design makes it possible that farm machinery design is intuitive, flexible and convenient. At present, because the developed computer aided ergonomics software has not suitable human body database, which is needed in view of farm machinery design in China, the farm machinery design have deviation in ergonomics analysis. This article puts forward that using the open database interface procedure in CATIA to establish human body database which aims at the farm machinery design, and reading the human body data to ergonomics module of CATIA can product practical application virtual body, using human posture analysis and human activity analysis module to analysis the ergonomics in farm machinery, thus computer aided farm machinery designing method based on engineering can be realized.

  2. Computer Aided Multi-Data Fusion Dismount Modeling

    Science.gov (United States)

    2012-03-22

    dependent on a particular environmental condition. They are costly, cumbersome, and involve dedicated software practices and particular knowledge to operate...allow manipulation of 2D matrices, like Microsoft Excel or Libre Office. The second alternative is to modify an already created model (MEM). The model... software . Therefore, with the described computer aided multi-data dismount model the researcher will be able to attach signatures to any desired

  3. Computer-Aided College Algebra: Learning Components that Students Find Beneficial

    Science.gov (United States)

    Aichele, Douglas B.; Francisco, Cynthia; Utley, Juliana; Wescoatt, Benjamin

    2011-01-01

    A mixed-method study was conducted during the Fall 2008 semester to better understand the experiences of students participating in computer-aided instruction of College Algebra using the software MyMathLab. The learning environment included a computer learning system for the majority of the instruction, a support system via focus groups (weekly…

  4. Two-stage Keypoint Detection Scheme for Region Duplication Forgery Detection in Digital Images.

    Science.gov (United States)

    Emam, Mahmoud; Han, Qi; Zhang, Hongli

    2018-01-01

    In digital image forensics, copy-move or region duplication forgery detection became a vital research topic recently. Most of the existing keypoint-based forgery detection methods fail to detect the forgery in the smooth regions, rather than its sensitivity to geometric changes. To solve these problems and detect points which cover all the regions, we proposed two steps for keypoint detection. First, we employed the scale-invariant feature operator to detect the spatially distributed keypoints from the textured regions. Second, the keypoints from the missing regions are detected using Harris corner detector with nonmaximal suppression to evenly distribute the detected keypoints. To improve the matching performance, local feature points are described using Multi-support Region Order-based Gradient Histogram descriptor. Based on precision-recall rates and commonly tested dataset, comprehensive performance evaluation is performed. The results demonstrated that the proposed scheme has better detection and robustness against some geometric transformation attacks compared with state-of-the-art methods. © 2017 American Academy of Forensic Sciences.

  5. Computer aided control engineering

    DEFF Research Database (Denmark)

    Szymkat, Maciej; Ravn, Ole

    1997-01-01

    Current developments in the field of Computer Aided Control Engineering (CACE) have a visible impact on the design methodologies and the structure of the software tools supporting them. Today control engineers has at their disposal libraries, packages or programming environments that may...... in CACE enhancing efficient flow of information between the tools supporting the following phases of the design process. In principle, this flow has to be two-way, and more or less automated, in order to enable the engineer to observe the propagation of the particular design decisions taken at various...... levels.The major conclusions of the paper are related with identifying the factors affecting the software tool integration in a way needed to facilitate design "inter-phase" communication. These are: standard application interfaces, dynamic data exchange mechanisms, code generation techniques and general...

  6. Phased searching with NEAT in a time-scaled framework: experiments on a computer-aided detection system for lung nodules.

    Science.gov (United States)

    Tan, Maxine; Deklerck, Rudi; Cornelis, Jan; Jansen, Bart

    2013-11-01

    In the field of computer-aided detection (CAD) systems for lung nodules in computed tomography (CT) scans, many image features are presented and many artificial neural network (ANN) classifiers with various structural topologies are analyzed; frequently, the classifier topologies are selected by trial-and-error experiments. To avoid these trial and error approaches, we present a novel classifier that evolves ANNs using genetic algorithms, called "Phased Searching with NEAT in a Time or Generation-Scaled Framework", integrating feature selection with the classification task. We analyzed our method's performance on 360 CT scans from the public Lung Image Database Consortium database. We compare our method's performance with other more-established classifiers, namely regular NEAT, Feature-Deselective NEAT (FD-NEAT), fixed-topology ANNs, and support vector machines (SVMs) using ten-fold cross-validation experiments of all 360 scans. The results show that the proposed "Phased Searching" method performs better and faster than regular NEAT, better than FD-NEAT, and achieves sensitivities at 3 and 4 false positives (FP) per scan that are comparable with the fixed-topology ANN and SVM classifiers, but with fewer input features. It achieves a detection sensitivity of 83.0±9.7% with an average of 4FP/scan, for nodules with a diameter greater than or equal to 3mm. It also evolves networks with shorter evolution times and with lower complexities than regular NEAT (p=0.026 and pNEAT and by our approach shows that our approach searches for good solutions in lower dimensional search spaces, and evolves networks without superfluous structure. We have presented a novel approach that combines feature selection with the evolution of ANN topology and weights. Compared with the original threshold-based Phased Searching method of Green, our method requires fewer parameters and converges to the optimal network complexity required for the classification task at hand. The results of the

  7. Computer-Aided Test Flow in Core-Based Design

    NARCIS (Netherlands)

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the test-pattern generation and fault coverage determination in the core based design. The basic core-test strategy that one has to apply in the core-based design is stated in this work. A Computer-Aided Test (CAT) flow is proposed resulting in accurate fault coverage of

  8. PMD compensation in multilevel coded-modulation schemes with coherent detection using BLAST algorithm and iterative polarization cancellation.

    Science.gov (United States)

    Djordjevic, Ivan B; Xu, Lei; Wang, Ting

    2008-09-15

    We present two PMD compensation schemes suitable for use in multilevel (M>or=2) block-coded modulation schemes with coherent detection. The first scheme is based on a BLAST-type polarization-interference cancellation scheme, and the second scheme is based on iterative polarization cancellation. Both schemes use the LDPC codes as channel codes. The proposed PMD compensations schemes are evaluated by employing coded-OFDM and coherent detection. When used in combination with girth-10 LDPC codes those schemes outperform polarization-time coding based OFDM by 1 dB at BER of 10(-9), and provide two times higher spectral efficiency. The proposed schemes perform comparable and are able to compensate even 1200 ps of differential group delay with negligible penalty.

  9. Improving performance of breast cancer risk prediction using a new CAD-based region segmentation scheme

    Science.gov (United States)

    Heidari, Morteza; Zargari Khuzani, Abolfazl; Danala, Gopichandh; Qiu, Yuchen; Zheng, Bin

    2018-02-01

    Objective of this study is to develop and test a new computer-aided detection (CAD) scheme with improved region of interest (ROI) segmentation combined with an image feature extraction framework to improve performance in predicting short-term breast cancer risk. A dataset involving 570 sets of "prior" negative mammography screening cases was retrospectively assembled. In the next sequential "current" screening, 285 cases were positive and 285 cases remained negative. A CAD scheme was applied to all 570 "prior" negative images to stratify cases into the high and low risk case group of having cancer detected in the "current" screening. First, a new ROI segmentation algorithm was used to automatically remove useless area of mammograms. Second, from the matched bilateral craniocaudal view images, a set of 43 image features related to frequency characteristics of ROIs were initially computed from the discrete cosine transform and spatial domain of the images. Third, a support vector machine model based machine learning classifier was used to optimally classify the selected optimal image features to build a CAD-based risk prediction model. The classifier was trained using a leave-one-case-out based cross-validation method. Applying this improved CAD scheme to the testing dataset, an area under ROC curve, AUC = 0.70+/-0.04, which was significantly higher than using the extracting features directly from the dataset without the improved ROI segmentation step (AUC = 0.63+/-0.04). This study demonstrated that the proposed approach could improve accuracy on predicting short-term breast cancer risk, which may play an important role in helping eventually establish an optimal personalized breast cancer paradigm.

  10. Money Laundering Detection Framework to Link the Disparate and Evolving Schemes

    OpenAIRE

    Murad Mehmet; Miguel Fuentes Buchholtz

    2013-01-01

    Money launderers hide traces of their transactions with the involvement of entities that participate in sophisticated schemes. Money laundering detection requires unraveling concealed connections among multiple but seemingly unrelated human money laundering networks, ties among actors of those schemes, and amounts of funds transferred among those entities. The link among small networks, either financial or social, is the primary factor that facilitates money laundering. Hence, the analysis of...

  11. Touchable Computing: Computing-Inspired Bio-Detection.

    Science.gov (United States)

    Chen, Yifan; Shi, Shaolong; Yao, Xin; Nakano, Tadashi

    2017-12-01

    We propose a new computing-inspired bio-detection framework called touchable computing (TouchComp). Under the rubric of TouchComp, the best solution is the cancer to be detected, the parameter space is the tissue region at high risk of malignancy, and the agents are the nanorobots loaded with contrast medium molecules for tracking purpose. Subsequently, the cancer detection procedure (CDP) can be interpreted from the computational optimization perspective: a population of externally steerable agents (i.e., nanorobots) locate the optimal solution (i.e., cancer) by moving through the parameter space (i.e., tissue under screening), whose landscape (i.e., a prescribed feature of tissue environment) may be altered by these agents but the location of the best solution remains unchanged. One can then infer the landscape by observing the movement of agents by applying the "seeing-is-sensing" principle. The term "touchable" emphasizes the framework's similarity to controlling by touching the screen with a finger, where the external field for controlling and tracking acts as the finger. Given this analogy, we aim to answer the following profound question: can we look to the fertile field of computational optimization algorithms for solutions to achieve effective cancer detection that are fast, accurate, and robust? Along this line of thought, we consider the classical particle swarm optimization (PSO) as an example and propose the PSO-inspired CDP, which differs from the standard PSO by taking into account realistic in vivo propagation and controlling of nanorobots. Finally, we present comprehensive numerical examples to demonstrate the effectiveness of the PSO-inspired CDP for different blood flow velocity profiles caused by tumor-induced angiogenesis. The proposed TouchComp bio-detection framework may be regarded as one form of natural computing that employs natural materials to compute.

  12. Statistical-techniques-based computer-aided diagnosis (CAD) using texture feature analysis: application in computed tomography (CT) imaging to fatty liver disease

    Science.gov (United States)

    Chung, Woon-Kwan; Park, Hyong-Hu; Im, In-Chul; Lee, Jae-Seung; Goo, Eun-Hoe; Dong, Kyung-Rae

    2012-09-01

    This paper proposes a computer-aided diagnosis (CAD) system based on texture feature analysis and statistical wavelet transformation technology to diagnose fatty liver disease with computed tomography (CT) imaging. In the target image, a wavelet transformation was performed for each lesion area to set the region of analysis (ROA, window size: 50 × 50 pixels) and define the texture feature of a pixel. Based on the extracted texture feature values, six parameters (average gray level, average contrast, relative smoothness, skewness, uniformity, and entropy) were determined to calculate the recognition rate for a fatty liver. In addition, a multivariate analysis of the variance (MANOVA) method was used to perform a discriminant analysis to verify the significance of the extracted texture feature values and the recognition rate for a fatty liver. According to the results, each texture feature value was significant for a comparison of the recognition rate for a fatty liver ( p fatty liver had the same scale as that for the F-value, showing 100% (average gray level) at the maximum and 80% (average contrast) at the minimum. Therefore, the recognition rate is believed to be a useful clinical value for the automatic detection and computer-aided diagnosis (CAD) using the texture feature value. Nevertheless, further study on various diseases and singular diseases will be needed in the future.

  13. CT colonography: effect of computer-aided detection of colonic polyps as a second and concurrent reader for general radiologists with moderate experience in CT colonography

    International Nuclear Information System (INIS)

    Mang, Thomas; Ringel, Helmut; Weber, Michael; Bogoni, Luca; Anand, Vikram X.; Hermosillo, Gerardo; Raykar, Vikas; Salganicoff, Marcos; Wolf, Matthias; Chandra, Dass; Curtin, Andrew J.; Lev-Toaff, Anna S.; Noah, Ralph; Shaw, Robert; Summerton, Susan; Tappouni, Rafel F.R.; Obuchowski, Nancy A.

    2014-01-01

    To assess the effectiveness of computer-aided detection (CAD) as a second reader or concurrent reader in helping radiologists who are moderately experienced in computed tomographic colonography (CTC) to detect colorectal polyps. Seventy CTC datasets (34 patients: 66 polyps ≥6 mm; 36 patients: no abnormalities) were retrospectively reviewed by seven radiologists with moderate CTC experience. After primary unassisted evaluation, a CAD second read and, after a time interval of ≥4 weeks, a CAD concurrent read were performed. Areas under the receiver operating characteristic (ROC) curve (AUC), along with per-segment, per-polyp and per-patient sensitivities, and also reading times, were calculated for each reader with and without CAD. Of seven readers, 86 % and 71 % achieved a higher accuracy (segment-level AUC) when using CAD as second and concurrent reader respectively. Average segment-level AUCs with second and concurrent CAD (0.853 and 0.864) were significantly greater (p < 0.0001) than average AUC in the unaided evaluation (0.781). Per-segment, per-polyp, and per-patient sensitivities for polyps ≥6 mm were significantly higher in both CAD reading paradigms compared with unaided evaluation. Second-read CAD reduced readers' average segment and patient specificity by 0.007 and 0.036 (p = 0.005 and 0.011), respectively. CAD significantly improves the sensitivities of radiologists moderately experienced in CTC for polyp detection, both as second reader and concurrent reader. (orig.)

  14. Computer-Aided Test Flow in Core-Based Design

    NARCIS (Netherlands)

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the efficient test-pattern generation in a core-based design. A consistent Computer-Aided Test (CAT) flow is proposed based on the required core-test strategy. It generates a test-pattern set for the embedded cores with high fault coverage and low DfT area overhead. The CAT

  15. New tools to aid in scientific computing and visualization

    International Nuclear Information System (INIS)

    Wallace, M.G.; Christian-Frear, T.L.

    1992-01-01

    In this paper, two computer programs are described which aid in the pre- and post-processing of computer generated data. CoMeT (Computational Mechanics Toolkit) is a customizable, interactive, graphical, menu-driven program that provides the analyst with a consistent user-friendly interface to analysis codes. Trans Vol (Transparent Volume Visualization) is a specialized tool for the scientific three-dimensional visualization of complex solids by the technique of volume rendering. Both tools are described in basic detail along with an application example concerning the simulation of contaminant migration from an underground nuclear repository

  16. Computerized detection of lung nodules in digital chest radiographs

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.

    1987-01-01

    Detection of cancerous lung nodules in chest radiographs is one of the more important tasks performed by a radiologist. In addition, the ''miss rate'' associated with the radiographic detection of lung nodules is approximately 30%. A computerized scheme that alerts the radiologist to possible locations of lung nodules should allow this number of false-negative diagnoses to be reduced. The authors are developing a computer-aided nodule detection scheme based on a difference image approach. They attempt to eliminate the camouflaging background structure of the normal lung anatomy by creating, from a single-projection chest image, two images: one in which the signal-to-noise ratio (SNR) of the nodule is maximized and another in which that SNR is suppressed while the processed background remains essentially the same. Thus, the difference between these two processed images should consist of the nodule superimposed on a relatively uniform background in which the detection task may be simplified. This difference image approach is fundamentally different from conventional subtraction techniques (e.g., temporal or dual-energy subtraction) in that the two images which are subtracted arise from the same single-projection chest radiograph. Once the difference image is obtained, thresholding is performed along with tests for circularity, size and growth in order to extract the nodules. It should be noted that once an original chest image is input to the computer the nodule detection process is totally automated

  17. Associated computational plasticity schemes for nonassociated frictional materials

    DEFF Research Database (Denmark)

    Krabbenhoft, K.; Karim, M. R.; Lyamin, A. V.

    2012-01-01

    A new methodology for computational plasticity of nonassociated frictional materials is presented. The new approach is inspired by the micromechanical origins of friction and results in a set of governing equations similar to those of standard associated plasticity. As such, procedures previously...... developed for associated plasticity are applicable with minor modification. This is illustrated by adaptation of the standard implicit scheme. Moreover, the governing equations can be cast in terms of a variational principle, which after discretization is solved by means of a newly developed second...

  18. Effect of Computer-Presented Organizational/Memory Aids on Problem Solving Behavior.

    Science.gov (United States)

    Steinberg, Esther R.; And Others

    This research studied the effects of computer-presented organizational/memory aids on problem solving behavior. The aids were either matrix or verbal charts shown on the display screen next to the problem. The 104 college student subjects were randomly assigned to one of the four conditions: type of chart (matrix or verbal chart) and use of charts…

  19. Computer Aided Design Tools for Extreme Environment Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project aims to provide Computer Aided Design (CAD) tools for radiation-tolerant, wide-temperature-range digital, analog, mixed-signal, and radio-frequency...

  20. 1000-Case Reader Study of Radiologists' Performance in Interpretation of Automated Breast Volume Scanner Images with a Computer-Aided Detection System.

    Science.gov (United States)

    Xu, Xiaojing; Bao, Lingyun; Tan, Yanjuan; Zhu, Luoxi; Kong, Fanlei; Wang, Wei

    2018-05-28

    The objective of our study was to assess, in a reader study, radiologists' performance in interpretation of automated breast volume scanner (ABVS) images with the aid of a computer-aided detection (CADe) system. Our study is a retrospective observer study with the purpose of investigating the effectiveness of using a CADe system as an aid for radiologists in interpretation of ABVS images. The multiple-reader, multiple-case study was designed to compare the diagnostic performance of radiologists with and without CADe. The study included 1000 cases selected from ABVS examinations in our institution in 2012. Among those cases were 206 malignant, 486 benign and 308 normal cases. The cancer cases were consecutive; the benign and normal cases were randomly selected. All malignant and benign cases were confirmed by biopsy or surgery, and normal cases were confirmed by 2-y follow-up. Reader performance was compared in terms of area under the receiver operating characteristic curve, sensitivity and specificity. Additionally, the reading time per case for each reader was recorded. Nine radiologists from our institution participated in the study. Three had more than 8 y of ultrasound experience and more than 4 y of ABVS experience (group A); 3 had more than 5 y of ultrasound experience (group B), and 3 had more than 1 y of ultrasound experience (group C). Both group B and group C had no ABVS experience. The CADe system used was the QVCAD System (QView Medical, Inc., Los Altos, CA, USA). It is designed to aid radiologists in searching for suspicious areas in ABVS images. CADe results are presented to the reader simultaneously with the ABVS images; that is, the radiologists read the ABVS images concurrently with the CADe results. The cases were randomly assigned for each reader into two equal-size groups, 1 and 2. Initially the readers read their group 1 cases with the aid of CADe and their group 2 cases without CADe. After a 1-mo washout period, they re-read their group 1

  1. Computer-aided system for diabetes care in Berlin, G.D.R.

    Science.gov (United States)

    Thoelke, H; Meusel, K; Ratzmann, K P

    1990-01-01

    In the Centre of Diabetes and Metabolic Disorders of Berlin, G.D.R., a computer-aided care system has been used since 1974, aiming at relieving physicians and medical staff from routine tasks and rendering possible epidemiological research on an unselected diabetes population of a defined area. The basis of the system is the data bank on diabetics (DB), where at present data from approximately 55,000 patients are stored. DB is used as a diabetes register of Berlin. On the basis of standardised criteria of diagnosis and therapy of diabetes mellitus in our dispensary care system, DB facilitates representative epidemiological analyses of the diabetic population, e.g. prevalence, incidence, duration of diabetes, and modes of treatment. The availability of general data on the population or the selection of specified groups of patients serves the management of the care system. Also, it supports the computer-aided recall of type II diabetics, treated either with diet alone or with diet and oral drugs. In this way, the standardised evaluation of treatment strategies in large populations of diabetics is possible on the basis of uniform metabolic criteria (blood glucose plus urinary glucose). The system consists of a main computer in the data processing unit and of personal computers in the diabetes centre which can be used either individually or as terminals to the main computer. During 14 years of experience, the computer-aided out-patient care of type II diabetics has proved efficient in a big-city area with a large population.

  2. Computer-aided diagnosis workstation and data base system for chest diagnosis based on multihelical CT images

    International Nuclear Information System (INIS)

    Satoh, H.; Niki, N.; Eguchi, K.; Masuda, H.; Machida, S.; Moriyama, N.

    2006-01-01

    We have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router, Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information. (author)

  3. Topology optimization aided structural design: Interpretation, computational aspects and 3D printing.

    Science.gov (United States)

    Kazakis, Georgios; Kanellopoulos, Ioannis; Sotiropoulos, Stefanos; Lagaros, Nikos D

    2017-10-01

    Construction industry has a major impact on the environment that we spend most of our life. Therefore, it is important that the outcome of architectural intuition performs well and complies with the design requirements. Architects usually describe as "optimal design" their choice among a rather limited set of design alternatives, dictated by their experience and intuition. However, modern design of structures requires accounting for a great number of criteria derived from multiple disciplines, often of conflicting nature. Such criteria derived from structural engineering, eco-design, bioclimatic and acoustic performance. The resulting vast number of alternatives enhances the need for computer-aided architecture in order to increase the possibility of arriving at a more preferable solution. Therefore, the incorporation of smart, automatic tools in the design process, able to further guide designer's intuition becomes even more indispensable. The principal aim of this study is to present possibilities to integrate automatic computational techniques related to topology optimization in the phase of intuition of civil structures as part of computer aided architectural design. In this direction, different aspects of a new computer aided architectural era related to the interpretation of the optimized designs, difficulties resulted from the increased computational effort and 3D printing capabilities are covered here in.

  4. Simple adaptive sparse representation based classification schemes for EEG based brain-computer interface applications.

    Science.gov (United States)

    Shin, Younghak; Lee, Seungchan; Ahn, Minkyu; Cho, Hohyun; Jun, Sung Chan; Lee, Heung-No

    2015-11-01

    One of the main problems related to electroencephalogram (EEG) based brain-computer interface (BCI) systems is the non-stationarity of the underlying EEG signals. This results in the deterioration of the classification performance during experimental sessions. Therefore, adaptive classification techniques are required for EEG based BCI applications. In this paper, we propose simple adaptive sparse representation based classification (SRC) schemes. Supervised and unsupervised dictionary update techniques for new test data and a dictionary modification method by using the incoherence measure of the training data are investigated. The proposed methods are very simple and additional computation for the re-training of the classifier is not needed. The proposed adaptive SRC schemes are evaluated using two BCI experimental datasets. The proposed methods are assessed by comparing classification results with the conventional SRC and other adaptive classification methods. On the basis of the results, we find that the proposed adaptive schemes show relatively improved classification accuracy as compared to conventional methods without requiring additional computation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Critiquing the Computer-Aided Design of Dental Prostheses.

    Science.gov (United States)

    Fitzpatrick, F. J.; And Others

    This paper describes RaPiD, a computer-aided assistant for the design of dental prostheses called removable partial dentures. The user manipulates icons directly to indicate the desired design solution to a given clinical situation. A developing design is represented as a logic database of components in a design; expert rules are applied as…

  6. DEVELOPMENT OF COMPUTER AIDED DESIGN OF CHAIN COUPLING

    Directory of Open Access Journals (Sweden)

    Sergey Aleksandrovich Sergeev

    2015-12-01

    Full Text Available The present paper describes the development stages of computer-aided design of chain couplings. The first stage is the automation of traditional design techniques (intermediate automation. The second integrated automation with the development of automated equipment and production technology, including on the basis of flexible manufacturing systems (high level of automation.

  7. Aiding the Detection of QRS Complex in ECG Signals by Detecting S Peaks Independently.

    Science.gov (United States)

    Sabherwal, Pooja; Singh, Latika; Agrawal, Monika

    2018-03-30

    In this paper, a novel algorithm for the accurate detection of QRS complex by combining the independent detection of R and S peaks, using fusion algorithm is proposed. R peak detection has been extensively studied and is being used to detect the QRS complex. Whereas, S peaks, which is also part of QRS complex can be independently detected to aid the detection of QRS complex. In this paper, we suggest a method to first estimate S peak from raw ECG signal and then use them to aid the detection of QRS complex. The amplitude of S peak in ECG signal is relatively weak than corresponding R peak, which is traditionally used for the detection of QRS complex, therefore, an appropriate digital filter is designed to enhance the S peaks. These enhanced S peaks are then detected by adaptive thresholding. The algorithm is validated on all the signals of MIT-BIH arrhythmia database and noise stress database taken from physionet.org. The algorithm performs reasonably well even for the signals highly corrupted by noise. The algorithm performance is confirmed by sensitivity and positive predictivity of 99.99% and the detection accuracy of 99.98% for QRS complex detection. The number of false positives and false negatives resulted while analysis has been drastically reduced to 80 and 42 against the 98 and 84 the best results reported so far.

  8. Computer Aided Battery Engineering Consortium

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, Ahmad

    2016-06-07

    A multi-national lab collaborative team was assembled that includes experts from academia and industry to enhance recently developed Computer-Aided Battery Engineering for Electric Drive Vehicles (CAEBAT)-II battery crush modeling tools and to develop microstructure models for electrode design - both computationally efficient. Task 1. The new Multi-Scale Multi-Domain model framework (GH-MSMD) provides 100x to 1,000x computation speed-up in battery electrochemical/thermal simulation while retaining modularity of particles and electrode-, cell-, and pack-level domains. The increased speed enables direct use of the full model in parameter identification. Task 2. Mechanical-electrochemical-thermal (MECT) models for mechanical abuse simulation were simultaneously coupled, enabling simultaneous modeling of electrochemical reactions during the short circuit, when necessary. The interactions between mechanical failure and battery cell performance were studied, and the flexibility of the model for various batteries structures and loading conditions was improved. Model validation is ongoing to compare with test data from Sandia National Laboratories. The ABDT tool was established in ANSYS. Task 3. Microstructural modeling was conducted to enhance next-generation electrode designs. This 3- year project will validate models for a variety of electrodes, complementing Advanced Battery Research programs. Prototype tools have been developed for electrochemical simulation and geometric reconstruction.

  9. Database organization for computer-aided characterization of laser diode

    International Nuclear Information System (INIS)

    Oyedokun, Z.O.

    1988-01-01

    Computer-aided data logging involves a huge amount of data which must be properly managed for optimized storage space, easy access, retrieval and utilization. An organization method is developed to enhance the advantages of computer-based data logging of the testing of the semiconductor injection laser which optimize storage space, permit authorized user easy access and inhibits penetration. This method is based on unique file identification protocol tree structure and command file-oriented access procedures

  10. Computer-Aided Design Method of Warp-Knitted Jacquard Spacer Fabrics

    Directory of Open Access Journals (Sweden)

    Li Xinxin

    2016-06-01

    Full Text Available Based on a further study on knitting and jacquard principles, this paper presents a mathematical design model to make computer-aided design of warp-knitted jacquard spacer fabrics more efficient. The mathematical model with matrix method employs three essential elements of chain notation, threading and Jacquard designing. With this model, the processing to design warp-knitted jacquard spacer fabrics with CAD software is also introduced. In this study, the sports shoes which have separated functional areas according to the feet structure and characteristics of movement are analysed. The results show the different patterns on Jacquard spacer fabrics that are seamlessly stitched with jacquard technics. The computer-aided design method of warp-knitted jacquard spacer fabrics is efficient and simple.

  11. Study on computer-aided simulation procedure for multicomponent separating cascade

    International Nuclear Information System (INIS)

    Kinoshita, Masahiro

    1982-11-01

    The present report reviews the author's study on the computer-aided simulation procedure for a multicomponent separating cascade. As a conclusion, two very powerful simulation procedures have been developed for cascades composed of separating elements whose separation factors are very large. They are applicable in cases where interstage flow rates are input variables for the calculation and stage separation factors are given either as constants or as functions of compositions of the up and down streams. As an application of the new procedure, a computer-aided simulation study has been performed for hydrogen isotope separating cascades by porous membrane method. A cascade system configuration is developed and pertinent design specifications are determined in an example case of the feed conditions and separation requirements. (author)

  12. [A computer-aided image diagnosis and study system].

    Science.gov (United States)

    Li, Zhangyong; Xie, Zhengxiang

    2004-08-01

    The revolution in information processing, particularly the digitizing of medicine, has changed the medical study, work and management. This paper reports a method to design a system for computer-aided image diagnosis and study. Combined with some good idea of graph-text system and picture archives communicate system (PACS), the system was realized and used for "prescription through computer", "managing images" and "reading images under computer and helping the diagnosis". Also typical examples were constructed in a database and used to teach the beginners. The system was developed by the visual developing tools based on object oriented programming (OOP) and was carried into operation on the Windows 9X platform. The system possesses friendly man-machine interface.

  13. Computer-aided Nonlinear Control System Design Using Describing Function Models

    CERN Document Server

    Nassirharand, Amir

    2012-01-01

    A systematic computer-aided approach provides a versatile setting for the control engineer to overcome the complications of controller design for highly nonlinear systems. Computer-aided Nonlinear Control System Design provides such an approach based on the use of describing functions. The text deals with a large class of nonlinear systems without restrictions on the system order, the number of inputs and/or outputs or the number, type or arrangement of nonlinear terms. The strongly software-oriented methods detailed facilitate fulfillment of tight performance requirements and help the designer to think in purely nonlinear terms, avoiding the expedient of linearization which can impose substantial and unrealistic model limitations and drive up the cost of the final product. Design procedures are presented in a step-by-step algorithmic format each step being a functional unit with outputs that drive the other steps. This procedure may be easily implemented on a digital computer with example problems from mecha...

  14. Development of computer-aided auto-ranging technique for a computed radiography system

    International Nuclear Information System (INIS)

    Ishida, M.; Shimura, K.; Nakajima, N.; Kato, H.

    1988-01-01

    For a computed radiography system, the authors developed a computer-aided autoranging technique in which the clinically useful image data are automatically mapped to the available display range. The preread image data are inspected to determine the location of collimation. A histogram of the pixels inside the collimation is evaluated regarding characteristic values such as maxima and minima, and then the optimal density and contrast are derived for the display image. The effect of the autoranging technique was investigated at several hospitals in Japan. The average rate of films lost due to undesirable density or contrast was about 0.5%

  15. Assisted supervision of a computer aided tele-operation system

    Energy Technology Data Exchange (ETDEWEB)

    Le Bars, H; Gravez, P; Fournier, R

    1994-12-31

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs.

  16. Assisted supervision of a computer aided tele-operation system

    International Nuclear Information System (INIS)

    Le Bars, H.; Gravez, P.; Fournier, R.

    1994-01-01

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs

  17. Progress in computer aided diagnosis for medical images by information technology

    International Nuclear Information System (INIS)

    Mekada, Yoshito

    2007-01-01

    This paper describes the history, present state and future view of computer aided diagnosis (CAD) based on processing, recognition and visualization of chest and abdominal images. A primitive feature of CAD is seen as early as in 1960's for lung cancer detection. Contemporarily, advances in medical imaging by CT, MRI, single photon emission computed tomography (SPECT) and positron emission tomography (PET) in multi-dimensions require doctors to read those vast information, where necessity of CAD is evident. At present, simultaneous CAD for multi-organs and multi-diseases is in progress, the interaction between images and medical doctors is leading to developing a newer system like virtual endoscopy, objective evaluation of CAD systems is necessary for its approval to authorities like fluorescein diacetate (FDA) with use of receiver operating characteristics analysis, and thus cooperation of medical and technological fields is more and more important. In future, CAD should be responsible for individual difference and for change in disease state, usable simultaneously for time and space, more recognized of its importance by doctors, and more useful in participation to therapeutic practice. (R.T.)

  18. Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology.

    Science.gov (United States)

    Arafa, Khalid A O

    2018-01-01

    To assess the level of evidence that supports the quality of fit for removable partial denture (RPD) fabricated by computer-aided designing/computer aided manufacturing (CAD/CAM) and rapid prototyping (RP) technology. Methods: An electronic search was performed in Google Scholar, PubMed, and Cochrane library search engines, using Boolean operators. All articles published in English and published in the period from 1950 until April 2017 were eligible to be included in this review. The total number of articles contained the search terms in any part of the article (including titles, abstracts, or article texts) were screened, which resulted in 214 articles. After exclusion of irrelevant and duplicated articles, 12 papers were included in this systematic review.  Results: All the included studies were case reports, except one study, which was a case series that recruited 10 study participants. The visual and tactile examination in the cast or clinically in the patient's mouth was the most-used method for assessment of the fit of RPDs. From all included studies, only one has assessed the internal fit between RPDs and oral tissues using silicone registration material. The vast majority of included studies found that the fit of RPDs ranged from satisfactory to excellent fit. Conclusion: Despite the lack of clinical trials that provide strong evidence, the available evidence supported the claim of good fit of RPDs fabricated by new technologies using CAD/CAM.

  19. A Complete Interactive Graphical Computer-Aided Instruction System.

    Science.gov (United States)

    Abrams, Steven Selby

    The use of interactive graphics in computer-aided instruction systems is discussed with emphasis placed on two requirements of such a system. The first is the need to provide the teacher with a useful tool with which to design and modify teaching sessions tailored to the individual needs and capabilities of the students. The second is the…

  20. Caesy: A software tool for computer-aided engineering

    Science.gov (United States)

    Wette, Matt

    1993-01-01

    A new software tool, Caesy, is described. This tool provides a strongly typed programming environment for research in the development of algorithms and software for computer-aided control system design. A description of the user language and its implementation as they currently stand are presented along with a description of work in progress and areas of future work.

  1. Implicit upwind schemes for computational fluid dynamics. Solution by domain decomposition

    International Nuclear Information System (INIS)

    Clerc, S.

    1998-01-01

    In this work, the numerical simulation of fluid dynamics equations is addressed. Implicit upwind schemes of finite volume type are used for this purpose. The first part of the dissertation deals with the improvement of the computational precision in unfavourable situations. A non-conservative treatment of some source terms is studied in order to correct some shortcomings of the usual operator-splitting method. Besides, finite volume schemes based on Godunov's approach are unsuited to compute low Mach number flows. A modification of the up-winding by preconditioning is introduced to correct this defect. The second part deals with the solution of steady-state problems arising from an implicit discretization of the equations. A well-posed linearized boundary value problem is formulated. We prove the convergence of a domain decomposition algorithm of Schwartz type for this problem. This algorithm is implemented either directly, or in a Schur complement framework. Finally, another approach is proposed, which consists in decomposing the non-linear steady state problem. (author)

  2. Computer training aids for nuclear operator training

    International Nuclear Information System (INIS)

    Phillips, J.G.P.; Binns, J.B.H.

    1983-01-01

    The Royal Navy's Nuclear Propulsion School at HMS SULTAN which is responsible for training all ratings and officers who operate Submarine Pressurised Water Reactor plants, has available a varied selection of classroom simulator training aids as well as purpose built Submarine Manoeuvring Room simulators. The use of these classroom training aids in the twelve months prior to Autumn 1981 is discussed. The advantages and disadvantages of using relatively expensive computer based aids to support classroom instruction for students who do not investigate mathematically the dynamics of the Reactor Plant are identified. The conclusions drawn indicate that for students of limited academic ability the classroom simulators are disproportionately expensive in cost, maintenance load, and instructional time. Secondly, the experience gained in the use of the Manoeuvring Room Simulators to train future operators who have just finished the academic phase of their training is outlined. The possible pitfalls for the instructor are discussed and the lessons learnt, concluding that these simulators provide a valuable substitute for the live plant enabling trainees to be brought up to a common standard and reducing their on job training time to an acceptable level. (author)

  3. Progress of the Computer-Aided Engineering of Electric Drive Vehicle Batteries (CAEBAT) (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, A. A.; Han, T.; Hartridge, S.; Shaffer, C.; Kim, G. H.; Pannala, S.

    2013-06-01

    This presentation, Progress of Computer-Aided Engineering of Electric Drive Vehicle Batteries (CAEBAT) is about simulation and computer-aided engineering (CAE) tools that are widely used to speed up the research and development cycle and reduce the number of build-and-break steps, particularly in the automotive industry. Realizing this, DOE?s Vehicle Technologies Program initiated the CAEBAT project in April 2010 to develop a suite of software tools for designing batteries.

  4. Computer aided analysis of disturbances

    International Nuclear Information System (INIS)

    Baldeweg, F.; Lindner, A.

    1986-01-01

    Computer aided analysis of disturbances and the prevention of failures (diagnosis and therapy control) in technological plants belong to the most important tasks of process control. Research in this field is very intensive due to increasing requirements to security and economy of process control and due to a remarkable increase of the efficiency of digital electronics. This publication concerns with analysis of disturbances in complex technological plants, especially in so called high risk processes. The presentation emphasizes theoretical concept of diagnosis and therapy control, modelling of the disturbance behaviour of the technological process and the man-machine-communication integrating artificial intelligence methods, e.g., expert system approach. Application is given for nuclear power plants. (author)

  5. Computer-Aided Template for Model Reuse, Development and Maintenance

    DEFF Research Database (Denmark)

    Fedorova, Marina; Sin, Gürkan; Gani, Rafiqul

    2014-01-01

    A template-based approach for model development is presented in this work. Based on a model decomposition technique, the computer-aided template concept has been developed. This concept is implemented as a software tool , which provides a user-friendly interface for following the workflow steps...

  6. Framework for Computer-Aided Evolution of Object-Oriented Designs

    NARCIS (Netherlands)

    Ciraci, S.; van den Broek, P.M.; Aksit, Mehmet

    2008-01-01

    In this paper, we describe a framework for the computer aided evolution of the designs of object-oriented software systems. Evolution mechanisms are software structures that prepare software for certain type of evolutions. The framework uses a database which holds the evolution mechanisms, modeled

  7. Computer aided fault tree synthesis

    International Nuclear Information System (INIS)

    Poucet, A.

    1983-01-01

    Nuclear as well as non-nuclear organisations are showing during the past few years a growing interest in the field of reliability analysis. This urges for the development of powerful, state of the art methods and computer codes for performing such analysis on complex systems. In this report an interactive, computer aided approach is discussed, based on the well known fault tree technique. The time consuming and difficut task of manually constructing a system model (one or more fault trees) is replaced by an efficient interactive procedure in which the flexibility and the learning process inherent to the manual approach are combined with the accuracy in the modelling and the speed of the fully automatical approach. The method presented is based upon the use of a library containing component models. The possibility of setting up a standard library of models of general use and the link with a data collection system are discussed. The method has been implemented in the CAFTS-SALP software package which is described shortly in the report

  8. Computer-Aided Diagnosis of Breast Cancer: A Multi-Center Demonstrator

    National Research Council Canada - National Science Library

    Floyd, Carey

    2000-01-01

    .... The focus has been to gather data from multiple sites in order to verify and whether the artificial neural network computer aid to the diagnosis of breast cancer can be translated between locations...

  9. Computer-Aided Experiment Planning toward Causal Discovery in Neuroscience.

    Science.gov (United States)

    Matiasz, Nicholas J; Wood, Justin; Wang, Wei; Silva, Alcino J; Hsu, William

    2017-01-01

    Computers help neuroscientists to analyze experimental results by automating the application of statistics; however, computer-aided experiment planning is far less common, due to a lack of similar quantitative formalisms for systematically assessing evidence and uncertainty. While ontologies and other Semantic Web resources help neuroscientists to assimilate required domain knowledge, experiment planning requires not only ontological but also epistemological (e.g., methodological) information regarding how knowledge was obtained. Here, we outline how epistemological principles and graphical representations of causality can be used to formalize experiment planning toward causal discovery. We outline two complementary approaches to experiment planning: one that quantifies evidence per the principles of convergence and consistency, and another that quantifies uncertainty using logical representations of constraints on causal structure. These approaches operationalize experiment planning as the search for an experiment that either maximizes evidence or minimizes uncertainty. Despite work in laboratory automation, humans must still plan experiments and will likely continue to do so for some time. There is thus a great need for experiment-planning frameworks that are not only amenable to machine computation but also useful as aids in human reasoning.

  10. Numerical Simulations of Reacting Flows Using Asynchrony-Tolerant Schemes for Exascale Computing

    Science.gov (United States)

    Cleary, Emmet; Konduri, Aditya; Chen, Jacqueline

    2017-11-01

    Communication and data synchronization between processing elements (PEs) are likely to pose a major challenge in scalability of solvers at the exascale. Recently developed asynchrony-tolerant (AT) finite difference schemes address this issue by relaxing communication and synchronization between PEs at a mathematical level while preserving accuracy, resulting in improved scalability. The performance of these schemes has been validated for simple linear and nonlinear homogeneous PDEs. However, many problems of practical interest are governed by highly nonlinear PDEs with source terms, whose solution may be sensitive to perturbations caused by communication asynchrony. The current work applies the AT schemes to combustion problems with chemical source terms, yielding a stiff system of PDEs with nonlinear source terms highly sensitive to temperature. Examples shown will use single-step and multi-step CH4 mechanisms for 1D premixed and nonpremixed flames. Error analysis will be discussed both in physical and spectral space. Results show that additional errors introduced by the AT schemes are negligible and the schemes preserve their accuracy. We acknowledge funding from the DOE Computational Science Graduate Fellowship administered by the Krell Institute.

  11. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration.

    Science.gov (United States)

    Juntavee, Niwut; Sirisathit, Issarawas

    2018-01-01

    This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel-chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey's honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system ( p marginal gap than the conventional cast metal restoration ( p marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration.

  12. How update schemes influence crowd simulations

    International Nuclear Information System (INIS)

    Seitz, Michael J; Köster, Gerta

    2014-01-01

    Time discretization is a key modeling aspect of dynamic computer simulations. In current pedestrian motion models based on discrete events, e.g. cellular automata and the Optimal Steps Model, fixed-order sequential updates and shuffle updates are prevalent. We propose to use event-driven updates that process events in the order they occur, and thus better match natural movement. In addition, we present a parallel update with collision detection and resolution for situations where computational speed is crucial. Two simulation studies serve to demonstrate the practical impact of the choice of update scheme. Not only do density-speed relations differ, but there is a statistically significant effect on evacuation times. Fixed-order sequential and random shuffle updates with a short update period come close to event-driven updates. The parallel update scheme overestimates evacuation times. All schemes can be employed for arbitrary simulation models with discrete events, such as car traffic or animal behavior. (paper)

  13. Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems.

    Science.gov (United States)

    Park, Jong-Kyoung; Lee, Wan-Sun; Kim, Hae-Young; Kim, Woong-Chul; Kim, Ji-Hwan

    2015-04-01

    To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

  14. A computer-aided molecular design framework for crystallization solvent design

    DEFF Research Database (Denmark)

    Karunanithi, Arunprakash T.; Achenie, Luke E.K.; Gani, Rafiqul

    2006-01-01

    One of the key decisions in designing solution crystallization processes is the selection of solvents. In this paper, we present a computer-aided molecular design (CAMD) framework for the design and selection of solvents and/or anti-solvents for solution crystallization. The CAMD problem is formu......One of the key decisions in designing solution crystallization processes is the selection of solvents. In this paper, we present a computer-aided molecular design (CAMD) framework for the design and selection of solvents and/or anti-solvents for solution crystallization. The CAMD problem...... solvent molecules. Solvent design and selection for two types of solution crystallization processes namely cooling crystallization and drowning out crystallization are presented. In the first case study, the design of single compound solvent for crystallization of ibuprofen, which is an important...

  15. Chapter 6 – Computer-Aided Molecular Design and Property Prediction

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Zhang, L.; Kalakul, Sawitree

    2017-01-01

    for the initial stages of the design/development process. Therefore, computer-aided molecular design and property prediction techniques are two topics that play important roles in chemical product design, analysis, and application. In this chapter, an overview of the concepts, methods, and tools related......Today's society needs many chemical-based products for its survival, nutrition, health, transportation, agriculture, and the functioning of processes. Chemical-based products have to be designed/developed in order to meet these needs, while at the same time, they must be innovative and sustainable...... to these two topics are given. In addition, a generic computer-aided framework for the design of molecules, mixtures, and blends is presented. The application of the framework is highlighted for molecular products through two case studies involving the design of refrigerants and surfactants....

  16. Energy-aware memory management for embedded multimedia systems a computer-aided design approach

    CERN Document Server

    Balasa, Florin

    2011-01-01

    Energy-Aware Memory Management for Embedded Multimedia Systems: A Computer-Aided Design Approach presents recent computer-aided design (CAD) ideas that address memory management tasks, particularly the optimization of energy consumption in the memory subsystem. It explains how to efficiently implement CAD solutions, including theoretical methods and novel algorithms. The book covers various energy-aware design techniques, including data-dependence analysis techniques, memory size estimation methods, extensions of mapping approaches, and memory banking approaches. It shows how these techniques

  17. A Computer-Aided Diagnosis System for Breast Cancer Combining Digital Mammography and Genomics

    Science.gov (United States)

    2006-05-01

    Huang, "Breast cancer diagnosis using self-organizing map for sonography." Ultrasound Med. Biol. 26, 405 (2000). 20 K. Horsch, M.L. Giger, L.A. Venta ...L.A. Venta , "Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography." Acad Radiol 11, 272 (2004). 22 W. Chen...418. 27. Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography

  18. Development of a control scheme of homodyne detection for extracting ponderomotive squeezing from a Michelson interferometer

    International Nuclear Information System (INIS)

    Sakata, Shihori; Kawamura, Seiji; Sato, Shuichi; Somiya, Kentaro; Arai, Koji; Fukushima, Mitsuhiro; Sugamoto, Akio

    2006-01-01

    We developed a control scheme of homodyne detection. To operate the homodyne detector as easy as possible, a simple Michelson interferometer is used. Here a motivation that the control scheme of the homodyne detection is developed is for our future experiment of extracting the ponderomotively squeezed vacuum fluctuations. To obtain the best signalto- noise ratio using the homodyne detection, the homodyne phase should be optimized. The optimization of the homodyne phase is performed by changing a phase of a local oscillator for the homodyne detection from a point at which a signal is maximized. In fact, in this experiment, using the developed control scheme, we locked the Michelson interferometer with the homodyne detector and changed the phase of the local oscillator for the homodyne detection. Then, we measured signals quantity changed by changing the phase of the local oscillator for the homodyne detection. Here we used the output from the homodyne detection as the signal

  19. A spectrally efficient detect-and-forward scheme with two-tier adaptive cooperation

    KAUST Repository

    Benjillali, Mustapha

    2011-09-01

    We propose a simple relay-based adaptive cooperation scheme to improve the spectral efficiency of "Detect-and-Forward" (DetF) half-duplex relaying in fading channels. In a new common framework, we show that the proposed scheme offers considerable gainsin terms of the achievable information ratescompared to conventional DetF relaying schemes for both orthogonal and non-orthogonal source/relay transmissions. The analysis leads on to a general adaptive cooperation strategy based on the maximization of information rates at the destination which needs to observe only the average signal-to-noise ratios of the links. © 2006 IEEE.

  20. An overview of interactive computer graphics and its application to computer-aided engineering and design

    International Nuclear Information System (INIS)

    Van Dam, A.

    1983-01-01

    The purpose of this brief birds-eye view of interactive graphics is to list the key ideas, and to show how one of the most important application areas, Computer Aided Engineering/Design takes advantage of it. (orig.)