WorldWideScience

Sample records for computer controlled scanning

  1. Software of the control computer of HPD scanning device

    International Nuclear Information System (INIS)

    Belyaev, A.V.; Rubtsov, V.F.; Slepnev, S.K.; Susov, Yu.I.

    1979-01-01

    Specific features of HPD measuring system are considered which are important for TPA-1001i computer programming, being the control computer of scanning device. The instruction language intended for interacting the computer with HPD electronics is given. Resident, auxiliary and test subprograms including those for interrupt handling, for monitoring, a driver for the operation with a teletype, a loader, a cross-assembler are described

  2. A study on Computer-controlled Ultrasonic Scanning Device

    International Nuclear Information System (INIS)

    Huh, H.; Park, C. S.; Hong, S. S.; Park, J. H.

    1989-01-01

    Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipment has been one of the important research and development(R and D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develop Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials

  3. Computer controlled scanning systems for quantitative track measurements

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Preston, C.C.; Ruddy, F.H.

    1982-01-01

    The status of three computer cntrolled systems for quantitative track measurements is described. Two systems, an automated optical track scanner (AOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third system, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Recent advances achieved with these systems are presented, with emphasis placed upon the current limitation of these systems for reactor neutron dosimetry

  4. Development of a scanning proton microprobe - computer-control, elemental mapping and applications

    International Nuclear Information System (INIS)

    Loevestam, Goeran.

    1989-08-01

    A scanning proton microprobe set-up has been developed at the Pelletron accelerator in Lund. A magnetic beam scanning system and a computer-control system for beam scanning and data aquisition is described. The computer system consists of a VMEbus front-end computer and a μVax-II host-computer, interfaced by means of a high-speed data link. The VMEbus computer controls data acquisition, beam charge monitoring and beam scanning while the more sophisticated work of elemental mapping and spectrum evaluations is left to the μVax-II. The calibration of the set-up is described as well as several applications. Elemental micro patterns in tree rings and bark has been investigated by means of elemental mapping and quantitative analysis. Large variations of elemental concentrations have been found for several elements within a single tree ring. An external beam set-up has been developed in addition to the proton microprobe set-up. The external beam has been used for the analysis of antique papyrus documents. Using a scanning sample procedure and particle induced X-ray emission (PIXE) analysis, damaged and missing characters of the text could be made visible by means of multivariate statistical data evaluation and elemental mapping. Also aspects of elemental mapping by means of scanning μPIXE analysis are discussed. Spectrum background, target thickness variations and pile-up are shown to influence the structure of elemental maps considerably. In addition, a semi-quantification procedure has been developed. (author)

  5. Full surface examination of small spheres with a computer controlled scanning electron microscope

    International Nuclear Information System (INIS)

    Ward, C.M.; Willenborg, D.L.; Montgomery, K.L.

    1979-01-01

    This report discusses a computer automated stage and Scanning Electron Microscopy (SEM) system for detecting defects in glass spheres for inertial confinement laser fusion experiments. This system detects submicron defects and permits inclusion of acceptable spheres in targets after examination. The stage used to examine and manipulate the spheres through 4π steradians is described. Primary image recording is made on a roster scanning video disc. The need for SEM stability and methods of achieving it are discussed

  6. Computed tomography automatic exposure control techniques in 18F-FDG oncology PET-CT scanning.

    Science.gov (United States)

    Iball, Gareth R; Tout, Deborah

    2014-04-01

    Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging. An audit of 70 patients was performed for half-body CT scans taken on a GE Discovery 690, Philips Gemini TF and Siemens Biograph mCT (all 64-slice CT). Patient demographic and dose information was recorded and image noise was calculated as the SD of Hounsfield units in the liver. A direct comparison of the AEC systems was made by scanning a Rando phantom on all three systems for a range of AEC settings. The variation in dose and image quality with patient weight was significantly different for all three systems, with the GE system showing the largest variation in dose with weight and Philips the least. Image noise varied with patient weight in Philips and Siemens systems but was constant for all weights in GE. The z-axis mA profiles from the Rando phantom demonstrate that these differences are caused by the nature of the tube current modulation techniques applied. The mA profiles varied considerably according to the AEC settings used. CT AEC techniques from the three manufacturers yield significantly different tube current modulation patterns and hence deliver different doses and levels of image quality across a range of patient weights. Users should be aware of how their system works and of steps that could be taken to optimize imaging protocols.

  7. Data acquisition and control for gamma scanning

    International Nuclear Information System (INIS)

    Barnes, B.K.; Murray, A.S.; Quintana, J.N.

    1980-01-01

    A new computer-based data acquisition and control unit has been installed in the Los Alamos Scientific Laboratory (LASL) system for scanning irradiated reactor fuel pins. The scanning mechanism is controlled by a commercial multichannel analyzer via a CAMAC link with an intelligent crate controller. The scanning and control unit consists of three linked LSI-11 computers. The multitasking capability of the commercial operation system allows control decisions to be based upon currently acquiring data

  8. Accurate three dimensional characterization of ultrasonic sound fields (by computer controlled rotational scanning)

    International Nuclear Information System (INIS)

    Gundtoft, H.E.; Nielsen, T.

    1981-07-01

    A rotational scanning system has recently been developed at Risoe National Laboratory. It allows sound fields from ultrasonic transducers to be examined in 3 dimensions. Using different calculation and plotting programs, any section in the sound field can be plotted. Results from examination of transducers for automatic inspection are presented. (author)

  9. Computer graphic display of cardiac CT scans

    International Nuclear Information System (INIS)

    Palmer, R.; Carlsson, E.

    1982-01-01

    In order to improve spatial conception and quantitative assessment of the cardiac structures based on cardiac computed tomography, methods for computer graphic display were developed. Excised hearts and living dogs with myocardial infarctions were subjected to CT scanning. The data on the scanner tapes were processed to provide isodensity plots, linear section plots, time-weighted integrated isodensity plots as well as topographical density displays and three-dimensional spatial reconstructions of single and multi-layer scans. (orig.)

  10. Conversion of a whole-body counter into a low-level whole-body scanning system controlled by a process computer

    International Nuclear Information System (INIS)

    Hamann, C.M.

    1976-01-01

    The report outlines the status of a research project in which a whole body counter with fixed geometries is converted into a scanning type system. The purpose of the project is the development of an adaptive system controlled by a process computer. The home-made scanning mechanics is explained, and a description is given of the advantages and the problems inherent in the application of step motors. For economic reasons no CAMAC system was purchased; instead, interfaces from and to the computer were designed which allowed the process periphery to be connected and operated. The inexpensive and relatively simple home-made designs are outlined; the example quoted refers to the conversion of a teletype output into a fast electronic data interface. (orig./ORU) [de

  11. Minimising medically unwarranted computed tomography scans

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    As computed tomography (CT) is such a superb diagnostic tool and individual CT risks are small, whenever a CT scan is clinically warranted, the CT benefit/risk balance is by far in the patient’s favour. However, if a CT scan is not clinically warranted, this balance shifts dramatically. It is likely that at least 25% of CT scans fall into this latter category, in that they could either be replaced with alternative imaging modalities or could be avoided entirely. Use of clinical decision rules for CT usage represents a powerful approach for slowing down the increase in CT usage, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they may not be clinically helpful.

  12. The cost-effectiveness of the RSI QuickScan intervention programme for computer workers: Results of an economic evaluation alongside a randomised controlled trial.

    Science.gov (United States)

    Speklé, Erwin M; Heinrich, Judith; Hoozemans, Marco J M; Blatter, Birgitte M; van der Beek, Allard J; van Dieën, Jaap H; van Tulder, Maurits W

    2010-11-11

    The costs of arm, shoulder and neck symptoms are high. In order to decrease these costs employers implement interventions aimed at reducing these symptoms. One frequently used intervention is the RSI QuickScan intervention programme. It establishes a risk profile of the target population and subsequently advises interventions following a decision tree based on that risk profile. The purpose of this study was to perform an economic evaluation, from both the societal and companies' perspective, of the RSI QuickScan intervention programme for computer workers. In this study, effectiveness was defined at three levels: exposure to risk factors, prevalence of arm, shoulder and neck symptoms, and days of sick leave. The economic evaluation was conducted alongside a randomised controlled trial (RCT). Participating computer workers from 7 companies (N = 638) were assigned to either the intervention group (N = 320) or the usual care group (N = 318) by means of cluster randomisation (N = 50). The intervention consisted of a tailor-made programme, based on a previously established risk profile. At baseline, 6 and 12 month follow-up, the participants completed the RSI QuickScan questionnaire. Analyses to estimate the effect of the intervention were done according to the intention-to-treat principle. To compare costs between groups, confidence intervals for cost differences were computed by bias-corrected and accelerated bootstrapping. The mean intervention costs, paid by the employer, were 59 euro per participant in the intervention and 28 euro in the usual care group. Mean total health care and non-health care costs per participant were 108 euro in both groups. As to the cost-effectiveness, improvement in received information on healthy computer use as well as in their work posture and movement was observed at higher costs. With regard to the other risk factors, symptoms and sick leave, only small and non-significant effects were found. In this study, the RSI QuickScan

  13. Ward nurses' knowledge of computed tomography scanning.

    Science.gov (United States)

    Majeed, M A; Nayeemuddin, M; Christie, M

    Patients benefit from and are reassured by advance information on procedures that they are to undergo. Ward nurses should have adequate knowledge of radiological investigations to ensure proper patient preparation and good interdepartmental communication to avoid delays and cancellations. This study was conducted to assess the ward nurses' knowledge of the process of computed tomography (CT) scanning. One hundred and twenty qualified nurses were asked to complete a questionnaire regarding CT scanning. The findings revealed a suboptimal level of awareness about the process. This is probably due to lack of formal teaching for nurses on the wards in regards the different radiological procedures and patient preparation. There is a strong case for better educational talks on rapidly changing radiological techniques for ward staff to ensure high-quality patient care.

  14. Computed tomography scans of metastatic hepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Fukuda, Haruyuki; Nemoto, Yutaka [Osaka City Univ. (Japan). Faculty of Medicine

    1984-01-01

    Computed tomography scans of 114 metastatic hepatic tumors were reviewed. Central low density was found in 82 cases (71.9%) and seems to be characteristic to metastatic hepatic tumors. Dynamic CT was performed on 34 cases, and 21 (61.8%) of these had ring enhancement at the arterial phase. Most of metastatic hepatic tumors could be differentiated from hepatocellular carcinoma. However, metastatic hepatic tumors from renal cell carcinoma, renal rhabdomyosarcoma, malignant melanoma and leiomyosarcoma could not be differentiated from hepatocellular carcinoma, even with use of dynamic study.

  15. Microprocessor-controlled scanning densitometer system

    International Nuclear Information System (INIS)

    Shurtliff, R.W.

    1980-04-01

    An Automated Scanning Densitometer System has been developed by uniting a microprocessor with a low energy x-ray densitometer system. The microprocessor controls the detector movement, provides self-calibration, compensates raw readings to provide time-linear output, controls both data storage and the host computer interface, and provides measurement output in engineering units for immediate reading. The densitometer, when used in a scanning mode, is a precision reference instrument that provides chordal average density measurements over the cross section of a pipe under steady-state flow conditions. Results have shown an improvement over the original densitometer in reliability and repeatability of the system, an a factor-of-five improvement in accuracy

  16. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  17. Chemical Characterization of Outdoor and Subway Fine (PM2.5-1.0) and Coarse (PM10-2.5) Particulate Matter in Seoul (Korea) Computer-Controlled Scanning Electron Microscopy (CCSEM)

    Science.gov (United States)

    Outdoor and indoor (subway) samples were collected by passive sampling in urban Seoul and analyzed with computer-controlled scanning electron microscopy coupled with energy dispersive x-ray spectroscopy (CCSEM-EDX). Soil/road dust particles accounted for 42-60% (by weight) of fin...

  18. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  19. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    International Nuclear Information System (INIS)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M.

    1989-01-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction

  20. Soft control of scanning probe microscope with high flexibility.

    Science.gov (United States)

    Liu, Zhenghui; Guo, Yuzheng; Zhang, Zhaohui; Zhu, Xing

    2007-01-01

    Most commercial scanning probe microscopes have multiple embedded digital microprocessors and utilize complex software for system control, which is not easily obtained or modified by researchers wishing to perform novel and special applications. In this paper, we present a simple and flexible control solution that just depends on software running on a single-processor personal computer with real-time Linux operating system to carry out all the control tasks including negative feedback, tip moving, data processing and user interface. In this way, we fully exploit the potential of a personal computer in calculating and programming, enabling us to manipulate the scanning probe as required without any special digital control circuits and related technical know-how. This solution has been successfully applied to a homemade ultrahigh vacuum scanning tunneling microscope and a multiprobe scanning tunneling microscope.

  1. 14'' x 17'' film recorder for computer-enhanced scans

    International Nuclear Information System (INIS)

    Morris, A.C. Jr.; Barclay, T.R.; Akin, T.E.; Hansard, M.C.; Gibbs, W.D.; Modzelewski, C.U.

    1976-01-01

    Physician acceptance of computer-enhanced radionuclide scan results, presented in the form of small Polaroid pictures, has been very limited for a number of subjective reasons. A new recorder was designed and constructed that presents the results of computer augmented scans through a medium that is quite familiar to doctors, the standard 14 in. x 17 in. x-ray film

  2. Synchronized control of spiral CT scan for security inspection device

    International Nuclear Information System (INIS)

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  3. Computed tomography scan optimization using head phantom and radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P., E-mail: lorena.cfernandes@hotmail.com, E-mail: carlosvelcab@hotmail.com, E-mail: pridili@gmail.com, E-mail: apmourao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro de Imagem Molecular do INCT-Medicina Molecular (CIMol/UFMG) Belo Horizonte (Brazil); Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte (Brazil)

    2017-11-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  4. Computed tomography scan optimization using head phantom and radiochromic films

    International Nuclear Information System (INIS)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P.

    2017-01-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  5. Study of Scanning Tunneling Microscope control electronics

    International Nuclear Information System (INIS)

    Oliva, A.J.; Pancarobo, M.; Denisenko, N.; Aguilar, M.; Rejon, V.; Pena, J.L.

    1994-01-01

    A theoretical study of Scanning Tunneling Microscope control electronics is made. The knowledge of its behaviour allows us to determine accurately the region where the unstable operation could effect the measurements, and also to set the optimal working parameters. Each feedback circuitry compound is discussed as well as their mutual interaction. Different working conditions analysis and results are presented. (Author) 12 refs

  6. Solid-State Quantum Computer Based on Scanning Tunneling Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Berman, G. P.; Brown, G. W.; Hawley, M. E.; Tsifrinovich, V. I.

    2001-08-27

    We propose a solid-state nuclear-spin quantum computer based on application of scanning tunneling microscopy (STM) and well-developed silicon technology. It requires the measurement of tunneling-current modulation caused by the Larmor precession of a single electron spin. Our envisioned STM quantum computer would operate at the high magnetic field ({approx}10 T) and at low temperature {approx}1 K .

  7. Solid-State Quantum Computer Based on Scanning Tunneling Microscopy

    International Nuclear Information System (INIS)

    Berman, G. P.; Brown, G. W.; Hawley, M. E.; Tsifrinovich, V. I.

    2001-01-01

    We propose a solid-state nuclear-spin quantum computer based on application of scanning tunneling microscopy (STM) and well-developed silicon technology. It requires the measurement of tunneling-current modulation caused by the Larmor precession of a single electron spin. Our envisioned STM quantum computer would operate at the high magnetic field (∼10 T) and at low temperature ∼1 K

  8. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  9. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    International Nuclear Information System (INIS)

    Marchiori, Edson; Irion, Klaus Loureiro; Zanetti, Glaucia; Missrie, Israel; Sato, Juliana

    2008-01-01

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  10. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Meirelles, Gustavo Souza Portes [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil); Irion, Klaus Loureiro [The Royal Liverpool University Hospital, Liverpool (United Kingdom); Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil); Missrie, Israel [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Diagnostico por Imagem; Sato, Juliana [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Otorrinolaringologia e Cirurgia de Cabeca e Pescoco

    2008-12-15

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  11. Dynamic computed tomography scanning of benign bone lesions: Preliminary results

    International Nuclear Information System (INIS)

    Levine, E.; Neff, J.R.

    1983-01-01

    The majority of benign bone lesions can be evaluated adequately using conventional radiologic techniques. However, it is not always possible to differentiate reliably between different types of benign bone lesions on the basis of plain film appearances alone. Dynamic computed tomography (CT) scanning provides a means for further characterizing such lesions by assessing their degree of vascularity. Thus, it may help in distinguishing an osteoid osteoma, which has a hypervascular nidus, from a Brodie's abscess, which is avascular. Dynamic CT scanning may also help in the differentiation between a fluid-containing simple bone cyst, which is avascular, and other solid or semi-solid benign bone lesions which slow varying degrees of vascularity. However, because of the additional irradiation involved, dynamic CT scanning should be reserved for evaluation of selected patients with benign bone lesions in whom the plain film findings are not definitive and in whom the CT findings may have a significant influence on management. (orig.)

  12. Osteotomy simulation and soft tissue prediction using computer tomography scans

    International Nuclear Information System (INIS)

    Teschner, M.; Girod, S.; Girod, B.

    1999-01-01

    In this paper, a system is presented that can be used to simulate osteotomies of the skull and to estimate the resulting of tissue changes. Thus, the three-dimensional, photorealistic, postoperative appearance of a patient can be assessed. The system is based on a computer tomography scan and a photorealistic laser scan of the patient's face. In order to predict the postoperative appearance of a patient the soft tissue must follow the movement of the underlying bone. In this paper, a multi-layer soft tissue model is proposed that is based on springs. It incorporates features like skin turgor, gravity and sliding bone contact. The prediction of soft tissue changes due to bone realignments is computed using a very efficient and robust optimization method. The system can handle individual patient data sets and has been tested with several clinical cases. (author)

  13. A computer program for scanning transmission ion microscopy simulation

    International Nuclear Information System (INIS)

    Wu, R.; Shen, H.; Mi, Y.; Sun, M.D.; Yang, M.J.

    2005-01-01

    With the installation of the Scanning Proton Microprobe system at Fudan University, we are in the process of developing a three-dimension reconstruction technique based on scanning transmission ion microscopy-computed tomography (STIM-CT). As the first step, a related computer program of STIM simulation has been established. This program is written in the Visual C++[reg], using the technique of OOP (Object Oriented Programming) and it is a standard multiple-document Windows[reg] program. It can be run with all MS Windows[reg] operating systems. The operating mode is the menu mode, using a multiple process technique. The stopping power theory is based on the Bethe-Bloch formula. In order to simplify the calculation, the improved cylindrical coordinate model was introduced in the program instead of a usual spherical or cylindrical coordinate model. The simulated results of a sample at several rotation angles are presented

  14. Computed tomography scan based prediction of the vulnerable carotid plaque

    DEFF Research Database (Denmark)

    Diab, Hadi Mahmoud Haider; Rasmussen, Lars Melholt; Duvnjak, Stevo

    2017-01-01

    BACKGROUND: Primary to validate a commercial semi-automated computed tomography angiography (CTA) -software for vulnerable plaque detection compared to histology of carotid endarterectomy (CEA) specimens and secondary validating calcifications scores by in vivo CTA with ex vivo non......-contrast enhanced computed tomography (NCCT). METHODS: From January 2014 to October 2016 53 patients were included retrospectively, using a cross-sectional design. All patients underwent both CTA and CEA. Sixteen patients had their CEA specimen NCCT scanned. The semi-automated CTA software analyzed carotid stenosis...

  15. Computer-controlled attenuator.

    Science.gov (United States)

    Mitov, D; Grozev, Z

    1991-01-01

    Various possibilities for applying electronic computer-controlled attenuators for the automation of physiological experiments are considered. A detailed description is given of the design of a 4-channel computer-controlled attenuator, in two of the channels of which the output signal can change by a linear step, in the other two channels--by a logarithmic step. This, together with the existence of additional programmable timers, allows to automate a wide range of studies in different spheres of physiology and psychophysics, including vision and hearing.

  16. High-resolution computed tomography scan of lumbosacral spine

    International Nuclear Information System (INIS)

    Lifson, A.; Heithoff, K.B.; Burton, C.V.; Ray, C.D.

    1981-01-01

    A GE 8800 computed tomography (CT) scanner was used in over 4,000 cases of acute and chronic low back pain. Practically unlimited potentials of the study were clearly demonstrated in the diagnosis of such conditions as central and lateral spinal stenosis, overgrowth of fusions, disk herniation and free extrusion. Nonenhanced CT scanning is capable of clear visualization of soft-tissue structures: nerve roots and ganglia, epidural fat, epidural fibrous tissue, and epidural veins. CT scanning has become a primary diagnostic modality in the Low Back Clinic at our institute, replacing myelography in the majority of cases. Enhancement of the image with metrizamide was found to be of limited diagnostic value in lumbar degenerative disk disease. However, the utilization of a radiopaque material is indicated in selected circumstances. (Auth.)

  17. Orthopedic applications of single photon emission computed Tomographic bone scanning

    International Nuclear Information System (INIS)

    Collier, B.D.

    1987-01-01

    When compared with planar bone scanning, single photon emission computed tomography (SPECT) has technical advantages of potential diagnostic significance. Planar imaging often superimposes substantial underlying or overlying activity on the bony structure of medical interest. SPECT, however, can be used to remove such unwanted activity. For example, in the hip the acetabulum extends downwards behind the femoral head. Therefore when using planar bone scanning techniques, the photon-deficient defect typical of avascular necrosis (AVN) of the femoral had may be obscured by activity originating in the underlying acetabulum. By using SPECT, underlying and overlying distributions of activity can be separated into sequential tomographic planes. For this reason SPECT facilitates the detection of AVN of the femoral head. When referring a patient without a history of malignancy for bone scanning, the orthopaedic surgeon usually has a specific clinical question involving a limited portion of the skeleton. Orthopaedic surgeons at their institution commonly use bone scanning to clarify the cause of back, hip or knee pain; to determine with a physiological test the significance of radiographic findings; and to establish the extent of disease at symptomatic skeletal sites such as the three compartments of the knee. In instances such as these, when clinical concern is limited to a specific anatomical region, a bone scan procedure that includes SPECT imaging of only a portion of the skeleton is appropriate. To date, SPECT of the skeletal system has most frequently been used to evaluate patients with pain the larger joints and bony structures such as the lumbar spine, hips, knees, or temporomandibular joints (TMJ)

  18. Wireless infrared computer control

    Science.gov (United States)

    Chen, George C.; He, Xiaofei

    2004-04-01

    Wireless mouse is not restricted by cable"s length and has advantage over its wired counterpart. However, all the mice available in the market have detection range less than 2 meters and angular coverage less than 180 degrees. Furthermore, commercial infrared mice are based on track ball and rollers to detect movements. This restricts them to be used in those occasions where users want to have dynamic movement, such as presentations and meetings etc. This paper presents our newly developed infrared wireless mouse, which has a detection range of 6 meters and angular coverage of 180 degrees. This new mouse uses buttons instead of traditional track ball and is developed to be a hand-held device like remote controller. It enables users to control cursor with a distance closed to computer and the mouse to be free from computer operation.

  19. Propulsion controlled aircraft computer

    Science.gov (United States)

    Cogan, Bruce R. (Inventor)

    2010-01-01

    A low-cost, easily retrofit Propulsion Controlled Aircraft (PCA) system for use on a wide range of commercial and military aircraft consists of an propulsion controlled aircraft computer that reads in aircraft data including aircraft state, pilot commands and other related data, calculates aircraft throttle position for a given maneuver commanded by the pilot, and then displays both current and calculated throttle position on a cockpit display to show the pilot where to move throttles to achieve the commanded maneuver, or is automatically sent digitally to command the engines directly.

  20. Computed tomographic brain scanning in the diagnosis of metastatic neoplasms

    International Nuclear Information System (INIS)

    Ringelstein, E.B.; Zeumer, H.; Hacke, W.; Keulers, P.

    1981-01-01

    Clinical investigations and computed brain scanning were done in 305 patients with primary extracerebral malignant tumours. One third of the patients had cerebral metastases. In most patients with brain metastases extracerebral secondary tumours were known already. Silent brain metastases were present in only 0.6% of all investigated tumour patients. All other patients had either objective neurologic-psychiatric defects or at least symptoms (headache, vomiting). Use of cranial computed tomography in all tumour patients as a pure screening method is thus not justified. The indication for the investigation is dependent on the clinical symptomatology. However, not only objective neurologic-psychiatric defects must be taken into account, but also occurrence of new symptoms. (orig.) [de

  1. RTSPM: real-time Linux control software for scanning probe microscopy.

    Science.gov (United States)

    Chandrasekhar, V; Mehta, M M

    2013-01-01

    Real time computer control is an essential feature of scanning probe microscopes, which have become important tools for the characterization and investigation of nanometer scale samples. Most commercial (and some open-source) scanning probe data acquisition software uses digital signal processors to handle the real time data processing and control, which adds to the expense and complexity of the control software. We describe here scan control software that uses a single computer and a data acquisition card to acquire scan data. The computer runs an open-source real time Linux kernel, which permits fast acquisition and control while maintaining a responsive graphical user interface. Images from a simulated tuning-fork based microscope as well as a standard topographical sample are also presented, showing some of the capabilities of the software.

  2. PEP computer control system

    International Nuclear Information System (INIS)

    1979-03-01

    This paper describes the design and performance of the computer system that will be used to control and monitor the PEP storage ring. Since the design is essentially complete and much of the system is operational, the system is described as it is expected to 1979. Section 1 of the paper describes the system hardware which includes the computer network, the CAMAC data I/O system, and the operator control consoles. Section 2 describes a collection of routines that provide general services to applications programs. These services include a graphics package, data base and data I/O programs, and a director programm for use in operator communication. Section 3 describes a collection of automatic and semi-automatic control programs, known as SCORE, that contain mathematical models of the ring lattice and are used to determine in real-time stable paths for changing beam configuration and energy and for orbit correction. Section 4 describes a collection of programs, known as CALI, that are used for calibration of ring elements

  3. Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans

    Science.gov (United States)

    2017-07-13

    Computed Tomography Scans by Autumn R Kulaga, Kathryn L Loftis, and Eric Murray Approved for public release; distribution is...Army Research Laboratory Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans by Autumn R Kulaga...Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  4. Chemical characterization of outdoor and subway fine (PM(2.5-1.0)) and coarse (PM(10-2.5)) particulate matter in Seoul (Korea) by computer-controlled scanning electron microscopy (CCSEM).

    Science.gov (United States)

    Byeon, Sang-Hoon; Willis, Robert; Peters, Thomas M

    2015-02-13

    Outdoor and indoor (subway) samples were collected by passive sampling in urban Seoul (Korea) and analyzed with computer-controlled scanning electron microscopy coupled with energy dispersive x-ray spectroscopy (CCSEM-EDX). Soil/road dust particles accounted for 42%-60% (by weight) of fine particulate matter larger than 1 µm (PM(2.5-1.0)) in outdoor samples and 18% of PM2.5-1.0 in subway samples. Iron-containing particles accounted for only 3%-6% in outdoor samples but 69% in subway samples. Qualitatively similar results were found for coarse particulate matter (PM(10-2.5)) with soil/road dust particles dominating outdoor samples (66%-83%) and iron-containing particles contributing most to subway PM(10-2.5) (44%). As expected, soil/road dust particles comprised a greater mass fraction of PM(10-2.5) than PM(2.5-1.0). Also as expected, the mass fraction of iron-containing particles was substantially less in PM(10-2.5) than in PM(2.5-1.0). Results of this study are consistent with known emission sources in the area and with previous studies, which showed high concentrations of iron-containing particles in the subway compared to outdoor sites. Thus, passive sampling with CCSEM-EDX offers an inexpensive means to assess PM(2.5-1.0) and PM(10-2.5) simultaneously and by composition at multiple locations.

  5. Precision controlled atomic resolution scanning transmission electron microscopy using spiral scan pathways

    Science.gov (United States)

    Sang, Xiahan; Lupini, Andrew R.; Ding, Jilai; Kalinin, Sergei V.; Jesse, Stephen; Unocic, Raymond R.

    2017-03-01

    Atomic-resolution imaging in an aberration-corrected scanning transmission electron microscope (STEM) can enable direct correlation between atomic structure and materials functionality. The fast and precise control of the STEM probe is, however, challenging because the true beam location deviates from the assigned location depending on the properties of the deflectors. To reduce these deviations, i.e. image distortions, we use spiral scanning paths, allowing precise control of a sub-Å sized electron probe within an aberration-corrected STEM. Although spiral scanning avoids the sudden changes in the beam location (fly-back distortion) present in conventional raster scans, it is not distortion-free. “Archimedean” spirals, with a constant angular frequency within each scan, are used to determine the characteristic response at different frequencies. We then show that such characteristic functions can be used to correct image distortions present in more complicated constant linear velocity spirals, where the frequency varies within each scan. Through the combined application of constant linear velocity scanning and beam path corrections, spiral scan images are shown to exhibit less scan distortion than conventional raster scan images. The methodology presented here will be useful for in situ STEM imaging at higher temporal resolution and for imaging beam sensitive materials.

  6. Computer aided control engineering

    DEFF Research Database (Denmark)

    Szymkat, Maciej; Ravn, Ole

    1997-01-01

    Current developments in the field of Computer Aided Control Engineering (CACE) have a visible impact on the design methodologies and the structure of the software tools supporting them. Today control engineers has at their disposal libraries, packages or programming environments that may...... in CACE enhancing efficient flow of information between the tools supporting the following phases of the design process. In principle, this flow has to be two-way, and more or less automated, in order to enable the engineer to observe the propagation of the particular design decisions taken at various...... levels.The major conclusions of the paper are related with identifying the factors affecting the software tool integration in a way needed to facilitate design "inter-phase" communication. These are: standard application interfaces, dynamic data exchange mechanisms, code generation techniques and general...

  7. 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?

    Science.gov (United States)

    Tseng, Yolanda D.; Wootton, Landon; Nyflot, Matthew; Apisarnthanarax, Smith; Rengan, Ramesh; Bloch, Charles; Sandison, George; St. James, Sara

    2018-01-01

    Four dimensional computed tomography (4DCT) scans are routinely used in radiation therapy to determine the internal treatment volume for targets that are moving (e.g. lung tumors). The use of these studies has allowed clinicians to create target volumes based upon the motion of the tumor during the imaging study. The purpose of this work is to determine if a target volume based on a single 4DCT scan at simulation is sufficient to capture thoracic motion. Phantom studies were performed to determine expected differences between volumes contoured on 4DCT scans and those on the evaluation CT scans (slow scans). Evaluation CT scans acquired during treatment of 11 patients were compared to the 4DCT scans used for treatment planning. The images were assessed to determine if the target remained within the target volume determined during the first 4DCT scan. A total of 55 slow scans were compared to the 11 planning 4DCT scans. Small differences were observed in phantom between the 4DCT volumes and the slow scan volumes, with a maximum of 2.9%, that can be attributed to minor differences in contouring and the ability of the 4DCT scan to adequately capture motion at the apex and base of the motion trajectory. Larger differences were observed in the patients studied, up to a maximum volume difference of 33.4%. These results demonstrate that a single 4DCT scan is not adequate to capture all thoracic motion throughout treatment.

  8. Pathophysiological study of experimental hydrocephalus with computed tomography (CT) scan

    International Nuclear Information System (INIS)

    Murata, Takaho

    1980-01-01

    In order to investigate the pathophysiological changes during a development of hydrocephalus, the observations employing computed tomography (CT) scans and monitorings of intracranial epidural pressure (EDP) were performed in a series of kaolin-induced canine hydrocephalus. According to ''volume index'' of ventricles which was calculated from printed-out CT numbers, great individual variations were recognized in the degree of a ventricular enlargement as well as the rate of EDP. They are thought to be due to the difference in types of hydrocephalus, which have been induced by a discrepancy in the site and degree of an obstruction caused by kaolin. Periventricular lucency (PVL) of various degrees were also detected on CT scans of experimental hydrocephalus. It was always marked in the superolateral angle of frontal horn of the lateral ventricles, and differed in degree from severe to mild. PVLs were distinct in the acute stage with high EDP, and gradually became indistinct and had a tendency to disappear thereafter along with decreased EDP. They immediately disappeared after shunting operation. The pathogenesis of PVL was investigated with histological examinations, as well as by using contrast enhancement, Metrizamide ventriculography, the analysis of linear density profiles, and the measurement of regional cerebral blood flow (rCBF). Consequently, PVLs in hydrocephalus are considered to represent an acute edema or a chronic CSF retention in the periventricular white matter caused by increase of water content. In other words, they are regarded as a sign of present or preceding intraventricular hypertension on CT scan, and may become a clinical indication for shunting operation. (author)

  9. Determination of dosimetric quantities in pediatric abdominal computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Jornada, Tiago da Silva [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostipo por Imagem; Silva, Teogenes Augusto da, E-mail: silvata@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-09-15

    Objective: aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods: the study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results: No significant difference was observed in the values for weighted air kerma index (C{sub W}), but the differences were relevant in values for volumetric air kerma index (C{sub VOL}), air kerma-length product (P{sub KL,CT}) and effective dose. Conclusion: Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, P{sub KL,CT} and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. (author)

  10. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    Science.gov (United States)

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  11. Using Cognitive Control in Software Defined Networking for Port Scan Detection

    Science.gov (United States)

    2017-07-01

    ARL-TR-8059 ● July 2017 US Army Research Laboratory Using Cognitive Control in Software -Defined Networking for Port Scan...Cognitive Control in Software -Defined Networking for Port Scan Detection by Vinod K Mishra Computational and Information Sciences Directorate, ARL...Technical Report 3. DATES COVERED (From - To) 15 June–31 July 2016 4. TITLE AND SUBTITLE Using Cognitive Control in Software -Defined Networking for

  12. Computer control applied to accelerators

    CERN Document Server

    Crowley-Milling, Michael C

    1974-01-01

    The differences that exist between control systems for accelerators and other types of control systems are outlined. It is further indicated that earlier accelerators had manual control systems to which computers were added, but that it is essential for the new, large accelerators to include computers in the control systems right from the beginning. Details of the computer control designed for the Super Proton Synchrotron are presented. The method of choosing the computers is described, as well as the reasons for CERN having to design the message transfer system. The items discussed include: CAMAC interface systems, a new multiplex system, operator-to-computer interaction (such as touch screen, computer-controlled knob, and non- linear track-ball), and high-level control languages. Brief mention is made of the contributions of other high-energy research laboratories as well as of some other computer control applications at CERN. (0 refs).

  13. Regrowth patterns of supratentorial gliomas: estimation from computed tomographic scans

    Energy Technology Data Exchange (ETDEWEB)

    Tsuboi, K.; Yoshii, Y.; Nakagawa, K.; Maki, Y.

    1986-12-01

    To clarify the regrowth patterns of benign and malignant gliomas, we chose 27 intervals (between two operations or between an operation and autopsy) from 21 patients with pathologically verified recurrent supratentorial gliomas. Serial computed tomographic (CT) scans of these cases were analyzed to determine the doubling time (Td) calculated from the change in volume of enhanced and low density areas, the enhancement effect graded from 0 to 4 according to the Hounsfield number, and the presence of dissemination and contralateral extension. We studied 5 benign gliomas (including 1 case of radiation necrosis), 8 malignant astrocytomas, and 8 glioblastomas. The Td's of enhanced areas on CT scans of benign gliomas, malignant astrocytomas, and glioblastomas were 937 +/- 66.5 days, 65.1 +/- 29.4 days, and 48.1 +/- 20.9 days, respectively. The Td's of low density areas were 895 +/- 130.6 days, 70.8 +/- 22.2 days, and 50.5 +/- 14.7 days. There was a significant correlation between the Td's of the enhanced and low density areas (0.97). The enhancement effect increased at recurrence in 55% of the cases, with an average increase of 1.1 grades. The increase in enhancement effect at recurrence showed a tendency to become smaller as the tumor's degree of anaplasia increased. Radiotherapy was effective in significantly retarding the growth rate of malignant gliomas, whose Td's were doubled. Although the Td's of both enhanced and low density areas of benign gliomas were significantly longer than those of malignant gliomas, there was no significant difference in the Td's of enhanced areas between malignant astrocytomas and glioblastomas.

  14. Regrowth patterns of supratentorial gliomas: estimation from computed tomographic scans

    International Nuclear Information System (INIS)

    Tsuboi, K.; Yoshii, Y.; Nakagawa, K.; Maki, Y.

    1986-01-01

    To clarify the regrowth patterns of benign and malignant gliomas, we chose 27 intervals (between two operations or between an operation and autopsy) from 21 patients with pathologically verified recurrent supratentorial gliomas. Serial computed tomographic (CT) scans of these cases were analyzed to determine the doubling time (Td) calculated from the change in volume of enhanced and low density areas, the enhancement effect graded from 0 to 4 according to the Hounsfield number, and the presence of dissemination and contralateral extension. We studied 5 benign gliomas (including 1 case of radiation necrosis), 8 malignant astrocytomas, and 8 glioblastomas. The Td's of enhanced areas on CT scans of benign gliomas, malignant astrocytomas, and glioblastomas were 937 +/- 66.5 days, 65.1 +/- 29.4 days, and 48.1 +/- 20.9 days, respectively. The Td's of low density areas were 895 +/- 130.6 days, 70.8 +/- 22.2 days, and 50.5 +/- 14.7 days. There was a significant correlation between the Td's of the enhanced and low density areas (0.97). The enhancement effect increased at recurrence in 55% of the cases, with an average increase of 1.1 grades. The increase in enhancement effect at recurrence showed a tendency to become smaller as the tumor's degree of anaplasia increased. Radiotherapy was effective in significantly retarding the growth rate of malignant gliomas, whose Td's were doubled. Although the Td's of both enhanced and low density areas of benign gliomas were significantly longer than those of malignant gliomas, there was no significant difference in the Td's of enhanced areas between malignant astrocytomas and glioblastomas

  15. Chemical Characterization of Outdoor and Subway Fine (PM2.5–1.0) and Coarse (PM10–2.5) Particulate Matter in Seoul (Korea) by Computer-Controlled Scanning Electron Microscopy (CCSEM)

    Science.gov (United States)

    Byeon, Sang-Hoon; Willis, Robert; Peters, Thomas M.

    2015-01-01

    Outdoor and indoor (subway) samples were collected by passive sampling in urban Seoul (Korea) and analyzed with computer-controlled scanning electron microscopy coupled with energy dispersive x-ray spectroscopy (CCSEM-EDX). Soil/road dust particles accounted for 42%–60% (by weight) of fine particulate matter larger than 1 µm (PM2.5–1.0) in outdoor samples and 18% of PM2.5–1.0 in subway samples. Iron-containing particles accounted for only 3%–6% in outdoor samples but 69% in subway samples. Qualitatively similar results were found for coarse particulate matter (PM10–2.5) with soil/road dust particles dominating outdoor samples (66%–83%) and iron-containing particles contributing most to subway PM10–2.5 (44%). As expected, soil/road dust particles comprised a greater mass fraction of PM10–2.5 than PM2.5–1.0. Also as expected, the mass fraction of iron-containing particles was substantially less in PM10–2.5 than in PM2.5–1.0. Results of this study are consistent with known emission sources in the area and with previous studies, which showed high concentrations of iron-containing particles in the subway compared to outdoor sites. Thus, passive sampling with CCSEM-EDX offers an inexpensive means to assess PM2.5–1.0 and PM10-2.5 simultaneously and by composition at multiple locations. PMID:25689348

  16. Chemical Characterization of Outdoor and Subway Fine (PM2.5–1.0 and Coarse (PM10–2.5 Particulate Matter in Seoul (Korea by Computer-Controlled Scanning Electron Microscopy (CCSEM

    Directory of Open Access Journals (Sweden)

    Sang-Hoon Byeon

    2015-02-01

    Full Text Available Outdoor and indoor (subway samples were collected by passive sampling in urban Seoul (Korea and analyzed with computer-controlled scanning electron microscopy coupled with energy dispersive x-ray spectroscopy (CCSEM-EDX. Soil/road dust particles accounted for 42%–60% (by weight of fine particulate matter larger than 1 µm (PM2.5–1.0 in outdoor samples and 18% of PM2.5–1.0 in subway samples. Iron-containing particles accounted for only 3%–6% in outdoor samples but 69% in subway samples. Qualitatively similar results were found for coarse particulate matter (PM10–2.5 with soil/road dust particles dominating outdoor samples (66%–83% and iron-containing particles contributing most to subway PM10–2.5 (44%. As expected, soil/road dust particles comprised a greater mass fraction of PM10–2.5 than PM2.5–1.0. Also as expected, the mass fraction of iron-containing particles was substantially less in PM10–2.5 than in PM2.5–1.0. Results of this study are consistent with known emission sources in the area and with previous studies, which showed high concentrations of iron-containing particles in the subway compared to outdoor sites. Thus, passive sampling with CCSEM-EDX offers an inexpensive means to assess PM2.5–1.0 and PM10-2.5 simultaneously and by composition at multiple locations.

  17. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  18. Improved controlled atmosphere high temperature scanning probe microscope

    DEFF Research Database (Denmark)

    Hansen, Karin Vels; Wu, Yuehua; Jacobsen, Torben

    2013-01-01

    fuel cells and electrolyzer cells. Here, we report on advanced improvements of our original controlled atmosphere high temperature scanning probe microscope, CAHT-SPM. The new microscope can employ a broad range of the scanning probe techniques including tapping mode, scanning tunneling microscopy......, scanning tunneling spectroscopy, conductive atomic force microscopy, and Kelvin probe force microscopy. The temperature of the sample can be as high as 850 °C. Both reducing and oxidizing gases such as oxygen, hydrogen, and nitrogen can be added in the sample chamber and the oxygen partial pressure (pO2...

  19. Dosimetric evaluation of cone beam computed tomography scanning protocols

    International Nuclear Information System (INIS)

    Soares, Maria Rosangela

    2015-01-01

    It was evaluated the cone beam computed tomography, CBCT scanning protocols, that was introduced in dental radiology at the end of the 1990's, and quickly became a fundamental examination for various procedures. Its main characteristic, the difference of medical CT is the beam shape. This study aimed to calculate the absorbed dose in eight tissues / organs of the head and neck, and to estimate the effective dose in 13 protocols and two techniques (stitched FOV e single FOV) of 5 equipment of different manufacturers of cone beam CT. For that purpose, a female anthropomorphic phantom was used, representing a default woman, in which were inserted thermoluminescent dosimeters at several points, representing organs / tissues with weighting values presented in the standard ICRP 103. The results were evaluated by comparing the dose according to the purpose of the tomographic image. Among the results, there is a difference up to 325% in the effective dose in relation to protocols with the same image goal. In relation to the image acquisition technique, the stitched FOV technique resulted in an effective dose of 5.3 times greater than the single FOV technique for protocols with the same image goal. In the individual contribution, the salivary glands are responsible for 31% of the effective dose in CT exams. The remaining tissues have also a significant contribution, 36%. The results drew attention to the need of estimating the effective dose in different equipment and protocols of the market, besides the knowledge of the radiation parameters and equipment manufacturing engineering to obtain the image. (author)

  20. Computer-Aided Detection of Kidney Tumor on Abdominal Computed Tomography Scans

    International Nuclear Information System (INIS)

    Kim, D.Y.; Park, J.W.

    2004-01-01

    Purpose: To implement a computer-aided detection system for kidney segmentation and kidney tumor detection on abdominal computed tomography (CT) scans. Material and Methods: Abdominal CT images were digitized with a film digitizer, and a gray-level threshold method was used to segment the kidney. Based on texture analysis performed on sample images of kidney tumors, a portion of the kidney tumor was selected as seed region for start point of the region-growing process. The average and standard deviations were used to detect the kidney tumor. Starting at the detected seed region, the region-growing method was used to segment the kidney tumor with intensity values used as an acceptance criterion for a homogeneous test. This test was performed to merge the neighboring region as kidney tumor boundary. These methods were applied on 156 transverse images of 12 cases of kidney tumors scanned using a G.E. Hispeed CT scanner and digitized with a Lumisys LS-40 film digitizer. Results: The computer-aided detection system resulted in a kidney tumor detection sensitivity of 85% and no false-positive findings. Conclusion: This computer-aided detection scheme was useful for kidney tumor detection and gave the characteristics of detected kidney tumors

  1. Scanning probe microscope simulator for the assessment of noise in scanning probe microscopy controllers

    International Nuclear Information System (INIS)

    Wutscher, T.; Niebauer, J.; Giessibl, F. J.

    2013-01-01

    We present an electronic circuit that allows to calibrate and troubleshoot scanning probe microscopy (SPM) controllers with respect to their noise performance. The control signal in an SPM is typically highly nonlinear—the tunneling current in scanning tunneling microscopy (STM) varies exponentially with distance. The exponential current-versus-voltage characteristics of diodes allow to model the current dependence in STM. Additional inputs allow to simulate the effects of external perturbations and the reactions of the control electronics. We characterized the noise performance of the feedback controller using the apparent topography roughness of recorded images. For a comparison of different STM controllers, an optimal gain parameter was determined by exploring settling times through a rectangular perturbation signal. We used the circuit to directly compare the performance of two types of SPM controllers used in our laboratory

  2. Control of peripheral units by satellite computer

    International Nuclear Information System (INIS)

    Tran, K.T.

    1974-01-01

    A computer system was developed allowing the control of nuclear physics experiments, and use of the results by means of graphical and conversational assemblies. This system which is made of two computers, one IBM-370/135 and one Telemecanique Electrique T1600, controls the conventional IBM peripherals and also the special ones made in the laboratory, such as data acquisition display and graphics units. The visual display is implemented by a scanning-type television, equipped with a light-pen. These units in themselves are universal, but their specifications were established to meet the requirements of nuclear physics experiments. The input-output channels of the two computers have been connected together by an interface, designed and implemented in the Laboratory. This interface allows the exchange of control signals and data (the data are changed from bytes into word and vice-versa). The T1600 controls the peripherals mentionned above according to the commands of the IBM370. Hence the T1600 has here the part of a satellite computer which allows conversation with the main computer and also insures the control of its special peripheral units [fr

  3. A Computer-Controlled Laser Bore Scanner

    Science.gov (United States)

    Cheng, Charles C.

    1980-08-01

    This paper describes the design and engineering of a laser scanning system for production applications. The laser scanning techniques, the timing control, the logic design of the pattern recognition subsystem, the digital computer servo control for the loading and un-loading of parts, and the laser probe rotation and its synchronization will be discussed. The laser inspection machine is designed to automatically inspect the surface of precision-bored holes, such as those in automobile master cylinders, without contacting the machined surface. Although the controls are relatively sophisticated, operation of the laser inspection machine is simple. A laser light beam from a commercially available gas laser, directed through a probe, scans the entire surface of the bore. Reflected light, picked up through optics by photoelectric sensors, generates signals that are fed to a mini-computer for processing. A pattern recognition techniques program in the computer determines acceptance or rejection of the part being inspected. The system's acceptance specifications are adjustable and are set to the user's established tolerances. However, the computer-controlled laser system is capable of defining from 10 to 75 rms surface finish, and voids or flaws from 0.0005 to 0.020 inch. Following the successful demonstration with an engineering prototype, the described laser machine has proved its capability to consistently ensure high-quality master brake cylinders. It thus provides a safety improvement for the automotive braking system. Flawless, smooth cylinder bores eliminate premature wearing of the rubber seals, resulting in a longer-lasting master brake cylinder and a safer and more reliable automobile. The results obtained from use of this system, which has been in operation about a year for replacement of a tedious, manual operation on one of the high-volume lines at the Bendix Hydraulics Division, have been very satisfactory.

  4. Feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in lung cancer treatment planning

    International Nuclear Information System (INIS)

    Xiao Jianghong; Zhang Hong; Gong Youling; Fu Yuchuan; Tang Bin; Wang Shichao; Jiang Qingfeng; Li Ping

    2010-01-01

    Background and purpose: To investigate the feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in 3-dimensional conformal radiotherapy (3D-CRT), stereotactic body radiation therapy (SBRT) and intensity-modulated radiotherapy (IMRT) treatment planning for lung cancers, respectively. Materials and methods: Twelve patients with bulky lung tumors and 14 patients with small lung tumors were retrospectively analyzed. Each patient took two sets of CT in the same position with active breathing control (ABC) technique before and after intravenous contrast agent (CA) injections. Bulky tumors were planned with 3D-CRT, while SBRT plans were generated for patients with small tumors based on CT scans with intravenous CA. In addition, IMRT plans were generated for patients with bulky tumors to continue on a planning study. All plans were copied and replaced on the scans without intravenous CA. The radiation doses calculated from the two sets of CTs were compared with regard to planning volumes (PTV), the organ at-risk (OAR) and the lungs using Wilcoxon's signed rank test. Results: In comparisons for 3D-CRT plans, CT scans with intravenous CA reduced the mean dose and the maximum dose of PTV with significant differences (p 95 ) for targets, respectively (p < 0.05). There was no statistical significance for lung parameters between two sets of scans in SBRT plans and IMRT plans. Conclusions: The enhanced CT scans can be used for both target delineation and treatment planning in 3D-CRT. The dose difference caused by intravenous CA is small. But for SBRT and IMRT, the minimum irradiation dose in targets may be estimated to be increased up to 2.71% while the maximum dose may be estimated to be decreased up to 1.36%. However, the difference in dose distribution in most cases were found to be clinical tolerable.

  5. Low-dose computed tomography image restoration using previous normal-dose scan

    International Nuclear Information System (INIS)

    Ma, Jianhua; Huang, Jing; Feng, Qianjin; Zhang, Hua; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2011-01-01

    Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use

  6. A multipoint feedback control system for scanned focussed ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Johnson, C.; Kress, R.; Roemer, R.; Hynynen, K.

    1987-01-01

    A multipoint feedback control system has been developed and tested for use with a scanned focussed ultrasound hyperthermia system. Extensive in-vivo tests (using a perfused organ model) have been made to evaluate the basic performance characteristics of the feedback control scheme for control of temperature in perfused media. The results of these tests are presented and compared with the predictions of a simulation routine. The control scheme was also tested in vivo using dogs' thighs and kidneys. Thigh experiments show the control scheme responds well to the affects of vasodilation and is able to maintain the targeted temperatures. In kidney experiments, where the rate of perfusion was controllable, the power adjusting algorithm successfully maintained uniform temperature distributions across regions of varying rates of perfusion. As a conclusion, the results show that this multipoint feedback controller scheme induces uniform temperature distributions when used with scanned focussed ultrasound systems

  7. Use of routine computed tomography brain scanning of psychiatry patients

    International Nuclear Information System (INIS)

    Agzarian, M.J.; Chryssidis, S.; Davies, R.P.; Pozza, C.H.

    2006-01-01

    The aim of this study was to evaluate the usefulness of CT of the brain in patients presenting with a psychiatric condition without focal neurological signs. The reports of 397 consecutive CT brain scans of patients presenting to two acute tertiary hospital psychiatric services over a 2-year period were assessed retrospectively. Of the 397 patients, 241 had psychosis, 87 had depression, 44 had bipolar affective disorder, seven had alcohol dependence, five had dementia, and the remaining 13 had a variety of diagnoses including personality disorder and transient ischaemic attack. Findings on 377 (95%) of the CT scans showed no abnormality. Specific abnormalities were described in 20 (5%) of the CT scans. Three scans showed non-specific minor abnormalities, which, when followed up by MRI, showed no relevant abnormality. All the abnormalities shown on CT were considered to be clinically unrelated to the patient's psychiatric condition. In conclusion, the pretest probability of finding a space-occupying lesion or other pertinent abnormality in patients presenting with psychiatric illnesses in this retrospective study appears not to be greater than that of the general population. The outcome of this study could be implemented to develop a clinical pathway for limiting assessment by CT for possible organic pathology in acute psychiatric illness. Copyright (2006) Blackwell Science Pty Ltd

  8. Quality control in quantitative computed tomography

    International Nuclear Information System (INIS)

    Jessen, K.A.; Joergensen, J.

    1989-01-01

    Computed tomography (CT) has for several years been an indispensable tool in diagnostic radiology, but it is only recently that extraction of quantitative information from CT images has been of practical clinical value. Only careful control of the scan parameters, and especially the scan geometry, allows useful information to be obtained; and it can be demonstrated by simple phantom measurements how sensitive a CT system can be to variations in size, shape and position of the phantom in the gantry aperture. Significant differences exist between systems that are not manifested in normal control of image quality and general performance tests. Therefore an actual system has to be analysed for its suitability for quantitative use of the images before critical clinical applications are justified. (author)

  9. Computer control system of TRISTAN

    International Nuclear Information System (INIS)

    Kurokawa, Shin-ichi; Shinomoto, Manabu; Kurihara, Michio; Sakai, Hiroshi.

    1984-01-01

    For the operation of a large accelerator, it is necessary to connect an enormous quantity of electro-magnets, power sources, vacuum equipment, high frequency accelerator and so on and to control them harmoniously. For the purpose, a number of computers are adopted, and connected with a network, in this way, a large computer system for laboratory automation which integrates and controls the whole system is constructed. As a distributed system of large scale, the functions such as electro-magnet control, file processing and operation control are assigned to respective computers, and the total control is made feasible by network connection, at the same time, as the interface with controlled equipment, the CAMAC (computer-aided measurement and control) is adopted to ensure the flexibility and the possibility of expansion of the system. Moreover, the language ''NODAL'' having network support function was developed so as to easily make software without considering the composition of more complex distributed system. The accelerator in the TRISTAN project is composed of an electron linear accelerator, an accumulation ring of 6 GeV and a main ring of 30 GeV. Two ring type accelerators must be synchronously operated as one body, and are controlled with one computer system. The hardware and software are outlined. (Kako, I.)

  10. New possibilities of three-dimensional reconstruction of computed tomography scans

    International Nuclear Information System (INIS)

    Herman, M.; Tarjan, Z.; Pozzi-Mucelli, R.S.

    1996-01-01

    Three-dimensional (3D) computed tomography (CT) scan reconstructions provide impressive and illustrative images of various parts of the human body. Such images are reconstructed from a series of basic CT scans by dedicated software. The state of the art in 3D computed tomography is demonstrated with emphasis on the imaging of soft tissues. Examples are presented of imaging the craniofacial and maxillofacial complex, central nervous system, cardiovascular system, musculoskeletal system, gastrointestinal and urogenital systems, and respiratory system, and their potential in clinical practice is discussed. Although contributing no new essential diagnostic information against conventional CT scans, 3D scans can help in spatial orientation. 11 figs., 25 refs

  11. Accuracy of a computed tomography scanning procedure to manufacture digital models.

    NARCIS (Netherlands)

    Darroudi, A.M.; Kuijpers-Jagtman, A.M.; Ongkosuwito, E.M.; Suttorp, C.M.; Bronkhorst, E.M.; Breuning, K.H.

    2017-01-01

    INTRODUCTION: Accurate articulation of the digital dental casts is crucial in orthodontic diagnosis and treatment planning. We aimed to determine the accuracy of manufacturing digital dental casts from computed tomography scanning of plaster casts regarding linear dimensions and interarch

  12. Computed tomographic scan of amenorrhea-galactorrhea syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Yutaka; Inoue, Yuichi; Takemoto, Kazumasa; Oda, Atsuo; Yahata, Satoshi (Osaka City Univ. (Japan). Faculty of Medicine)

    1984-05-01

    Thin (2 mm) section CT scans of a pituitary gland of 30 amenorrhea-galactorrhea patients were reviewed. Eleven out of 30 patients were diagnosed as having a pituitary adenoma (tumor group); nine prolactionomas were verified by surgery. Tumor density compared with normal pituitary gland was low in five, low-mixed in three and isodense in four. The upper margin of a prolactinoma was convexed upward in seven, flat in two and concaved downward in two. Pituitary stalk was deviated in two and not visualized in four. Serum prolactine level (PRL) was more than 130 ng/ml in tumor group. There was a positive correlation between the size of a prolactinoma and PRL. Four prolactinomas invaded the cavernous sinus; three of them showed higher PRL than 1,000 ng/ml.

  13. Computed tomographic scan of amenorrhea-galactorrhea syndrome

    International Nuclear Information System (INIS)

    Nemoto, Yutaka; Inoue, Yuichi; Takemoto, Kazumasa; Oda, Atsuo; Yahata, Satoshi

    1984-01-01

    Thin (2 mm) section CT scans of a pituitary gland of 30 amenorrhea-galactorrhea patients were reviewed. Eleven out of 30 patients were diagnosed to have a pituitary adenoma (tumor group); nine prolactionomas were verified by surgery. Tumor density compared with normal pituitary gland was low in five, low-mixed in three and isodense in four. The upper margin of a prolactinoma was convexed upward in seven, flat in two and concaved downward in two. Pituitary stalk was deviated in two and not visualized in four. Serum prolactine level (PRL) was more than 130 ng/ml in tumor group. There was a positive correlation between the size of a prolactinoma and PRL. Four prolactinomas invaded the cavernous sinus; three of them showed higher PRL than 1,000 ng/ml. (author)

  14. Computed tomographic (CT) scans in cerebral palsy (CP)

    International Nuclear Information System (INIS)

    Kolawole, T.M.; Patel, P.J.; Mahdi, A.H.

    1989-01-01

    The CT findings in 120 cerebral palsied children are analysed. The 72.5% positive findings are correlated with the clinical types, as well as the aetiological basis for the cerebral palsy. The spastic type, 83.3% of the total number of children, had the highest positive findings. The yield was increased in children with seizures (91.3%) and those in the postnatal group (90%), as well as those with birth trauma and neonatal asphyxia (94%). The findings were those of atrophy in 30.8%, hydrocephalus, in 10%, infarct in 11.6%, porencephaly in 8.3% and others. The atropic changes and their patterns are explained. Treatable lesions, such as tumour, hydrocephalus, subdural haematoma, porencephaly and hygroma were identified in 22.5% of cases. It is concluded that CT scan is definitely efficacious in the management of cerebral palsied children. (orig.)

  15. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans

    NARCIS (Netherlands)

    Ritchie, A.J.; Sanghera, C.; Jacobs, C.; Zhang, W.; Mayo, J.; Schmidt, H.; Gingras, M.; Pasian, S.; Stewart, L.; Tsai, S.; Manos, D.; Seely, J.M.; Burrowes, P.; Bhatia, R.; Atkar-Khattra, S.; Ginneken, B. van; Tammemagi, M.; Tsao, M.S.; Lam, S.; et al.,

    2016-01-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in

  16. Tangential scanning of hardwood logs: developing an industrial computer tomography scanner

    Science.gov (United States)

    Nand K. Gupta; Daniel L. Schmoldt; Bruce Isaacson

    1999-01-01

    It is generally believed that noninvasive scanning of hardwood logs such as computer tomography (CT) scanning prior to initial breakdown will greatly improve the processing of logs into lumber. This belief, however, has not translated into rapid development and widespread installation of industrial CT scanners for log processing. The roadblock has been more operational...

  17. Computer-controlled 3-D treatment delivery

    International Nuclear Information System (INIS)

    Fraass, Benedick A.

    1995-01-01

    scanned beam treatments will also be discussed. CCRT-related approaches to treatment plan generation and transfer, accelerator control systems, treatment delivery, verification, documentation and charting will also be discussed, including the importance of real-time portal imaging for conformal therapy. The potential benefits of 3-D computer-controlled conformal treatment delivery will be illustrated with results from on-going clinical dose escalation and normal tissue complication studies. Conclusion: A large amount of interest in computer-controlled conformal treatment delivery techniques has developed in recent years. This presentation will attempt to summarize the current status of clinical and research work in 3-D computer-controlled conformal therapy treatment techniques. Particular attention is paid to issues related to implementation and clinical use of this developing treatment modality

  18. Computational aspects of linear control

    CERN Document Server

    2002-01-01

    Many devices (we say dynamical systems or simply systems) behave like black boxes: they receive an input, this input is transformed following some laws (usually a differential equation) and an output is observed. The problem is to regulate the input in order to control the output, that is for obtaining a desired output. Such a mechanism, where the input is modified according to the output measured, is called feedback. The study and design of such automatic processes is called control theory. As we will see, the term system embraces any device and control theory has a wide variety of applications in the real world. Control theory is an interdisci­ plinary domain at the junction of differential and difference equations, system theory and statistics. Moreover, the solution of a control problem involves many topics of numerical analysis and leads to many interesting computational problems: linear algebra (QR, SVD, projections, Schur complement, structured matrices, localization of eigenvalues, computation of the...

  19. Analytical scanning evanescent microwave microscope and control stage

    Science.gov (United States)

    Xiang, Xiao-Dong; Gao, Chen; Duewer, Fred; Yang, Hai Tao; Lu, Yalin

    2009-06-23

    A scanning evanescent microwave microscope (SEMM) that uses near-field evanescent electromagnetic waves to probe sample properties is disclosed. The SEMM is capable of high resolution imaging and quantitative measurements of the electrical properties of the sample. The SEMM has the ability to map dielectric constant, loss tangent, conductivity, electrical impedance, and other electrical parameters of materials. Such properties are then used to provide distance control over a wide range, from to microns to nanometers, over dielectric and conductive samples for a scanned evanescent microwave probe, which enable quantitative non-contact and submicron spatial resolution topographic and electrical impedance profiling of dielectric, nonlinear dielectric and conductive materials. The invention also allows quantitative estimation of microwave impedance using signals obtained by the scanned evanescent microwave probe and quasistatic approximation modeling. The SEMM can be used to measure electrical properties of both dielectric and electrically conducting materials.

  20. Direct extraction of boundaries from computed tomography scans

    International Nuclear Information System (INIS)

    Thirion, J.P.

    1994-01-01

    This paper presents a method, based on the Filtered Backprojection technique (FBP), to extract directly the boundaries of X-ray images, without previous image reconstruction. The authors preprocess the raw data in order to compute directly the reconstructed values of the gradient or of the Laplacian at any location in the plane (defined with real coordinates). The reconstructed value of the gradient and of the Laplacian correspond to the exact mathematical definition of the differentials of the image. For noisy data, the authors propose also to use an extension of existing FBP techniques, adapted to the computation of the gradient and of the Laplacian. Finally, the authors show how to use the corresponding operators to perform the segmentation of a slice, without image reconstruction. Images of the reconstructed gradient, Laplacian, and segmented objects are presented

  1. Role of Postmortem Multislice Computed Tomography Scan in Close Blunt Head Injury

    Directory of Open Access Journals (Sweden)

    Prijo Sidipratomo

    2014-08-01

    Full Text Available BACKGROUND: Conventional autopsy in Indonesia is not well accepted as it is contrary to religion and culture. New radiological imaging method such as multislice computed tomography (MSCT scan has potential to be a diagnostic tool in forensic pathology. The purpose of this study is to determine the ability of MSCT scan in finding abnormalities in close blunt head injury compared with autopsy. METHODS: This study used descriptive qualitative method. Postmortem cases in Department of Forensic Medicine and Radiology of Dr. Cipto Mangunkusumo Hospital were selected based on inclusion criteria. Then MSCT scan and autopsy were conducted. MSCT scan and autopsy results were compared and analyzed. RESULTS: There were 491 postmortem cases of blunt head injury. However, only 10 cases fulfilled inclusion criteria. Subarachnoid haemorrhages were identified 100% with MSCT scan and 80% with autopsy. Cerebral oedemas were identified 100% either with MSCT scan and autopsy. Subdural haemorrhages were identified 100% with MSCT scan, while 50% with autopsy. Multiple fractures were identified 80% with MSCT scan, while 40% with auto. CONCLUSIONS: MSCT scan showed a sensitive detection in finding abnormalities in close blunt head injury. Therefore it could be as an alternative choice of examination in close blunt head injury cases. KEYWORDS: multislice computed tomography scan, postmortem, blunt head injury, autopsy.

  2. Ceftriaxone-associated pancreatitis captured on serial computed tomography scans

    Directory of Open Access Journals (Sweden)

    Nozomu Nakagawa, MD

    2018-02-01

    Full Text Available A 74-year-old man was treated with ceftriaxone for 5 days and subsequently experienced epigastric pain. Computed tomography (CT was performed 7 and 3 days before epigastralgia. Although the first CT image revealed no radiographic signs in his biliary system, the second CT image revealed dense radiopaque material in the gallbladder lumen. The third CT image, taken at symptom onset, showed high density in the common bile duct and enlargement of the pancreatic head. This is a very rare case of pseudolithiasis involving the common bile duct, as captured on a series of CT images.

  3. Ceftriaxone-associated pancreatitis captured on serial computed tomography scans.

    Science.gov (United States)

    Nakagawa, Nozomu; Ochi, Nobuaki; Yamane, Hiromichi; Honda, Yoshihiro; Nagasaki, Yasunari; Urata, Noriyo; Nakanishi, Hidekazu; Kawamoto, Hirofumi; Takigawa, Nagio

    2018-02-01

    A 74-year-old man was treated with ceftriaxone for 5 days and subsequently experienced epigastric pain. Computed tomography (CT) was performed 7 and 3 days before epigastralgia. Although the first CT image revealed no radiographic signs in his biliary system, the second CT image revealed dense radiopaque material in the gallbladder lumen. The third CT image, taken at symptom onset, showed high density in the common bile duct and enlargement of the pancreatic head. This is a very rare case of pseudolithiasis involving the common bile duct, as captured on a series of CT images.

  4. Methanol poisoning: brain computed tomography scan findings in four patients

    International Nuclear Information System (INIS)

    Patankar, T.; Prasad, S.; Rathod, K.; Bichile, L.; Karnad, D.

    1999-01-01

    Methanol, through its chief metabolite, formate, causes irreversible neurological damage. Methanol intoxication produces classic neuropathological changes and characteristic imaging findings. Computed tomography was performed on four patients who presented with a history of methanol poisoning. Prominent, hypodense lesions in the lentilform nuclei and peripheral white matter, sometimes with haemorrhage, were the characteristic imaging findings in the present patients. It was noted that the severity and extent of necrosis of the lentilform nuclei do not necessarily correlate with the clinical outcome. Copyright (1999) Blackwell Science Pty Ltd

  5. Computer controlled high voltage system

    Energy Technology Data Exchange (ETDEWEB)

    Kunov, B; Georgiev, G; Dimitrov, L [and others

    1996-12-31

    A multichannel computer controlled high-voltage power supply system is developed. The basic technical parameters of the system are: output voltage -100-3000 V, output current - 0-3 mA, maximum number of channels in one crate - 78. 3 refs.

  6. Personal computers in accelerator control

    International Nuclear Information System (INIS)

    Anderssen, P.S.

    1988-01-01

    The advent of the personal computer has created a popular movement which has also made a strong impact on science and engineering. Flexible software environments combined with good computational performance and large storage capacities are becoming available at steadily decreasing costs. Of equal importance, however, is the quality of the user interface offered on many of these products. Graphics and screen interaction is available in ways that were only possible on specialized systems before. Accelerator engineers were quick to pick up the new technology. The first applications were probably for controllers and data gatherers for beam measurement equipment. Others followed, and today it is conceivable to make personal computer a standard component of an accelerator control system. This paper reviews the experience gained at CERN so far and describes the approach taken in the design of the common control center for the SPS and the future LEP accelerators. The design goal has been to be able to integrate personal computers into the accelerator control system and to build the operator's workplace around it. (orig.)

  7. Computer controlled testing of batteries

    NARCIS (Netherlands)

    Kuiper, A.C.J.; Einerhand, R.E.F.; Visscher, W.

    1989-01-01

    A computerized testing device for batteries consists of a power supply, a multiplexer circuit connected to the batteries, a protection circuit, and an IBM Data Aquisition and Control Adapter card, connected to a personal computer. The software is written in Turbo-Pascal and can be easily adapted to

  8. Classifying and Visualising Roman Pottery using Computer-scanned Typologies

    Directory of Open Access Journals (Sweden)

    Jacqueline Christmas

    2018-05-01

    Full Text Available For many archaeological assemblages and type-series, accurate drawings of standardised pottery vessels have been recorded in consistent styles. This provides the opportunity to extract individual pot drawings and derive from them data that can be used for analysis and visualisation. Starting from PDF scans of the original pages of pot drawings, we have automated much of the process for locating, defining the boundaries, extracting and orientating each individual pot drawing. From these processed images, basic features such as width and height, the volume of the interior, the edges, and the shape of the cross-section outline are extracted and are then used to construct more complex features such as a measure of a pot's 'circularity'. Capturing these traits opens up new possibilities for (a classifying vessel form in a way that is sensitive to the physical characteristics of pots relative to other vessels in an assemblage, and (b visualising the results of quantifying assemblages using standard typologies. A frequently encountered problem when trying to compare pottery from different archaeological sites is that the pottery is classified into forms and labels using different standards. With a set of data from early Roman urban centres and related sites that has been labelled both with forms (e.g. 'platter' and 'bowl' and shape identifiers (based on the Camulodunum type-series, we use the extracted features from images to look both at how the pottery forms cluster for a given set of features, and at how the features may be used to compare finds from different sites.

  9. Use and impact of positron computed tomography scanning in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Mazziotta, J.C.; Engel, J. Jr.

    1984-01-01

    Through the effective combination of instrumentation, tracer kinetic principles, and radiopharmaceuticals, positron computed tomography (PET) allows for the analytic, noninvasive measurement of local tissue physiology in humans. A large number of studies have already been performed in patients with epilepsy using 18F-fluorodeoxyglucose (FDG) to measure local cerebral glucose utilization. In patients with complex partial epilepsy who are candidates for surgery, hypometabolic zones have been seen consistently (70%) in the interictal state. The complex anatomical and pathophysiological investigation of these hypometabolic zones is discussed. Ictal studies of patients with partial seizures have demonstrated a much more variable metabolic pattern which usually consists of hypermetabolism relative to baseline or interictal studies. Generalized epilepsy produced by electroconvulsive shock and petit mal epilepsy have been studied using FDG to estimate glucose metabolism.

  10. Characterization of Visual Scanning Patterns in Air Traffic Control.

    Science.gov (United States)

    McClung, Sarah N; Kang, Ziho

    2016-01-01

    Characterization of air traffic controllers' (ATCs') visual scanning strategies is a challenging issue due to the dynamic movement of multiple aircraft and increasing complexity of scanpaths (order of eye fixations and saccades) over time. Additionally, terminologies and methods are lacking to accurately characterize the eye tracking data into simplified visual scanning strategies linguistically expressed by ATCs. As an intermediate step to automate the characterization classification process, we (1) defined and developed new concepts to systematically filter complex visual scanpaths into simpler and more manageable forms and (2) developed procedures to map visual scanpaths with linguistic inputs to reduce the human judgement bias during interrater agreement. The developed concepts and procedures were applied to investigating the visual scanpaths of expert ATCs using scenarios with different aircraft congestion levels. Furthermore, oculomotor trends were analyzed to identify the influence of aircraft congestion on scan time and number of comparisons among aircraft. The findings show that (1) the scanpaths filtered at the highest intensity led to more consistent mapping with the ATCs' linguistic inputs, (2) the pattern classification occurrences differed between scenarios, and (3) increasing aircraft congestion caused increased scan times and aircraft pairwise comparisons. The results provide a foundation for better characterizing complex scanpaths in a dynamic task and automating the analysis process.

  11. Deriving motion from megavoltage localization cone beam computed tomography scans

    International Nuclear Information System (INIS)

    Alfredo C Siochi, R

    2009-01-01

    Cone beam computed tomography (CBCT) projection data consist of views of a moving point (e.g. diaphragm apex). The point is selected in identification views of extreme motion (two inhale, two exhale). The room coordinates of the extreme points are determined by source-to-view ray tracing intersections. Projected to other views, these points become opposite corners of a motion-bounding box. The view coordinates of the point, relative to the box, are used to interpolate between extreme room coordinates. Along with the views' time stamps, this provides the point's room coordinates as a function of time. CBCT-derived trajectories of a tungsten pin, moving 3 cm cranio-caudally and 1 cm elsewhere, deviate from expected ones by at most 1.06 mm. When deviations from the ideal imaging geometry are considered, mean errors are less than 0.2 mm. While CBCT-derived cranio-caudal positions are insensitive to the choice of identification views, the bounding box determination requires view separations between 15 and 163 deg. Inhale views with the two largest amplitudes should be used, though corrections can account for different amplitudes. The information could be used to calibrate motion surrogates, adaptively define phase triggers immediately before gated radiotherapy and provide phase and amplitude sorting for 4D CBCT.

  12. Dosimetry study using head dummy in computed tomography scans

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Do Carmo S, P.; Prata M, A.

    2017-10-01

    The concern in the amounts of radiation doses deposited in the patients is still great because the computed tomography (CT) exams are currently the ones that reach the highest levels of radiation deposited in the population. Brazilian legislation regulates the levels of doses deposited in patients since it is limited to estimating a maximum amount, depending on the region of the body to be exposed. Therefore is necessary to determine the amount of dose that is deposited in patients depending on the routine protocols used in the radio diagnosis services and thus, propose an optimization of these under the principles referring to dose limitation, optimization of radiological protection and of course, the justification of the practices. Experiments were conducted to determine the dose profile for routine head exams in an adult patient, using a physical simulator object of polymethylmethacrylate (PMMA) in cylindrical format with 4 peripheral orifices and one central one. Strips of radiochromic film were introduced in each of the holes to record the dose profile in each region and thus determine the amount of dose deposited in the entire volume of the simulator object. A General Electric 64-channel tomograph, typical of the radiology service, was used for voltages of 80, 100 and 120 kV with a fixed current of 200 ma, finding dose levels between 6.24 and 23.73 mGy. Noise analysis of the images was performed, finding that all of them met the acceptable diagnostic parameters. An optimized protocol is proposed for head CT exams with a voltage of 80 kV for images with a noise index of 0.5%. (Author)

  13. Control by personal computer and Interface 1

    International Nuclear Information System (INIS)

    Kim, Eung Mug; Park, Sun Ho

    1989-03-01

    This book consists of three chapters. The first chapter deals with basic knowledge of micro computer control which are computer system, micro computer system, control of the micro computer and control system for calculator. The second chapter describes Interface about basic knowledge such as 8255 parallel interface, 6821 parallel interface, parallel interface of personal computer, reading BCD code in parallel interface, IEEE-488 interface, RS-232C interface and transmit data in personal computer and a measuring instrument. The third chapter includes control experiment by micro computer, experiment by eight bit computer and control experiment by machine code and BASIC.

  14. Role of Postmortem Multislice Computed Tomography Scan in Close Blunt Head Injury

    OpenAIRE

    Sidipratomo, Prijo; Prija, Trijono Karmawan Sukana; Murtala, Bachtiar; Purwadianto, Agus; Lawrence, Gatot Susilo

    2014-01-01

    BACKGROUND: Conventional autopsy in Indonesia is not well accepted as it is contrary to religion and culture. New radiological imaging method such as multislice computed tomography (MSCT) scan has potential to be a diagnostic tool in forensic pathology. The purpose of this study is to determine the ability of MSCT scan in finding abnormalities in close blunt head injury compared with autopsy. METHODS: This study used descriptive qualitative method. Postmortem cases in Department of Forensic M...

  15. Integration of Digital Dental Casts in Cone-Beam Computed Tomography Scans

    OpenAIRE

    Rangel, Frits A.; Maal, Thomas J. J.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all reported methods have drawbacks. The aim of this feasibility study is to present a new simplified method to integrate digital dental casts into CBCT scans. In a patient scheduled for orthognathic ...

  16. PID controller simulator software for DC motor of gamma scanning

    International Nuclear Information System (INIS)

    Arjoni Amir

    2008-01-01

    Mostly PID controller (Proportional-Integral-Derivative) has been used in industry. For certain applications, it can be used as a Proportional (P) model only, or as a Proportional-Integral (PI) model. The aim of this paper is to design a PID controller simulator software for DC motor which is used in gamma scanning system. A DC motor is described as a plant of SISO (Single Input Single Output) which is used for pulling down the load (detector + casing) and gamma radiation source (Co-60 + container) by using sling cable. A DC motor consist of an armature and a rotor, the equivalent circuit of DC motor is shown in a transfer function equation between output parameter (angular speed DC motor) and input parameter (voltage of DC motor). Methods used for the process of PID controller design is to arrange the PID controller parameter (Kc, Ti, Td) so that there are more PID controller transfer function model which are able to control angular speed of DC motor in stable condition, as design criteria requirement is needed. Design criteria requirement for control system are the settling time < 3 second, overshoot < 5%, rise time = 0.25 second, steady state gain = 1 and peak time < 3 second with step response reference 1 rad/second. The result of simulation gives several models of PID controller in function transfer equation which is similar with design criteria requirement in a equation of function transfer of order 2 for numerator and order 1 for denominator. (author)

  17. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  18. A modeling of fuzzy logic controller on gamma scanning device

    International Nuclear Information System (INIS)

    Arjoni Amir

    2010-01-01

    Modeling and simulation of controller to set the high position and direction of the source of gamma radiation isotope Co-60 and Nal(TL) detector of gamma scanning device by using fuzzy logic controller FLC have been done. The high positions and in the right direction of gamma radiation and Nal (TI) detector obtained the optimal enumeration. The counting data obtained from gamma scanning device counting system is affected by the instability of high position and direction of the gamma radiation source and Nal(TI) detector or the height and direction are not equal between the gamma radiation source and Nal(TI) detector. Assumed a high position and direction of radiation sources can be fixed while the high position detector h (2, 1,0, -1, -2) can be adjusted up and down and the detector can be changed direction to the left or right angle ω (2, 1 , 0, -1, -2) when the position and direction are no longer aligned with the direction of the source of gamma radiation, the counting results obtained will not be optimal. Movement detector direction towards the left or right and the high detector arranged by the DC motor using fuzzy logic control in order to obtain the amount of output fuzzy logic control which forms the optimal output quantity count. The variation of height difference h between the source position of the gamma radiation detector and change direction with the detector angle ω becomes the input variable membership function (member function) whereas the fuzzy logic for the output variable membership function of fuzzy logic control output is selected scale fuzzy logic is directly proportional to the amount of optimal counting. From the simulation results obtained by the relationship between the amount of data output variable of fuzzy logic controller and the amount of data input variable height h and direction detector ω is depicted in graphical form surface. (author)

  19. Review of P-scan computer-based ultrasonic inservice inspection system. Supplement 1

    International Nuclear Information System (INIS)

    Harris, R.V. Jr.; Angel, L.J.

    1995-12-01

    This Supplement reviews the P-scan system, a computer-based ultrasonic system used for inservice inspection of piping and other components in nuclear power plants. The Supplement was prepared using the methodology described in detail in Appendix A of NUREG/CR-5985, and is based on one month of using the system in a laboratory. This Supplement describes and characterizes: computer system, ultrasonic components, and mechanical components; scanning, detection, digitizing, imaging, data interpretation, operator interaction, data handling, and record-keeping. It includes a general description, a review checklist, and detailed results of all tests performed

  20. Introduction of helical computed tomography affects patient selection for V/Q lung scan

    International Nuclear Information System (INIS)

    Zettinig, G.; Baudrexel, S.; Leitha, Th.

    2002-01-01

    Aim: Retrospective analysis for determination of the effect of helical computed tomography (HCT) on utilization of V/Q lung scanning to diagnose pulmonary embolism (PE) in a large general hospital. Methods: A total number of 2676 V/Q scans of in- and out-patients referred to our department between March 1992 and December 1998 and between April 1997 and December 1998 were analyzed by an identical group of nuclear physicians. Results: Neither the total number of annually performed V/Q scans (446 ± 135) nor the mean age of patients (56 years ± 17) changed significantly since the introduction of HCT. However, the referral pattern was different. The percentage of patients with high and intermediate probability for PE decreased significantly from 15.2% to 9.4% (p <0.01) and from 10.2% to 7.3% (p <0.05), respectively. Low probability scans significantly increased from 37.8% to 42.7% (p <0.05). The percentage of normal scans did not change significantly, however, there was a highly significant increase summarizing patients with normal and low probability scans (74.6% to 83.3%; p <0.01). Conclusion: The introduction of HCT affected the selection of patients referred for V/Q lung scanning since V/Q scanning was primarily used to exclude rather to confirm PE. (orig.)

  1. An electron beam linear scanning mode for industrial limited-angle nano-computed tomography

    Science.gov (United States)

    Wang, Chengxiang; Zeng, Li; Yu, Wei; Zhang, Lingli; Guo, Yumeng; Gong, Changcheng

    2018-01-01

    Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.

  2. The CESR computer control system

    International Nuclear Information System (INIS)

    Helmke, R.G.; Rice, D.H.; Strohman, C.

    1986-01-01

    The control system for the Cornell Electron Storage Ring (CESR) has functioned satisfactorily since its implementation in 1979. Key characteristics are fast tuning response, almost exclusive use of FORTRAN as a programming language, and efficient coordinated ramping of CESR guide field elements. This original system has not, however, been able to keep pace with the increasing complexity of operation of CESR associated with performance upgrades. Limitations in address space, expandability, access to data system-wide, and program development impediments have prompted the undertaking of a major upgrade. The system under development accomodates up to 8 VAX computers for all applications programs. The database and communications semaphores reside in a shared multi-ported memory, and each hardware interface bus is controlled by a dedicated 32 bit micro-processor in a VME based system. (orig.)

  3. Computer systems for nuclear installation data control

    International Nuclear Information System (INIS)

    1987-09-01

    The computer programs developed by Divisao de Instalacoes Nucleares (DIN) from Brazilian CNEN for data control on nuclear installations in Brazil are presented. The following computer programs are described: control of registered companies, control of industrial sources, irradiators and monitors; control of liable person; control of industry irregularities; for elaborating credence tests; for shielding analysis; control of waste refuge [pt

  4. Real-time depth monitoring and control of laser machining through scanning beam delivery system

    International Nuclear Information System (INIS)

    Ji, Yang; Grindal, Alexander W; Fraser, James M; Webster, Paul J L

    2015-01-01

    Scanning optics enable many laser applications in manufacturing because their low inertia allows rapid movement of the process beam across the sample. We describe our method of inline coherent imaging for real-time (up to 230 kHz) micron-scale (7–8 µm axial resolution) tracking and control of laser machining depth through a scanning galvo-telecentric beam delivery system. For 1 cm trench etching in stainless steel, we collect high speed intrapulse and interpulse morphology which is useful for further understanding underlying mechanisms or comparison with numerical models. We also collect overall sweep-to-sweep depth penetration which can be used for feedback depth control. For trench etching in silicon, we show the relationship of etch rate with average power and scan speed by computer processing of depth information without destructive sample post-processing. We also achieve three-dimensional infrared continuous wave (modulated) laser machining of a 3.96 × 3.96 × 0.5 mm 3 (length × width × maximum depth) pattern on steel with depth feedback. To the best of our knowledge, this is the first successful demonstration of direct real-time depth monitoring and control of laser machining with scanning optics. (paper)

  5. Micro computed tomography (CT) scanned anatomical gateway to insect pest bioinformatics

    Science.gov (United States)

    An international collaboration to establish an interactive Digital Video Library for a Systems Biology Approach to study the Asian citrus Psyllid and psyllid genomics/proteomics interactions is demonstrated. Advances in micro-CT, digital computed tomography (CT) scan uses X-rays to make detailed pic...

  6. Integration of digital dental casts in cone-beam computed tomography scans

    NARCIS (Netherlands)

    Rangel, F.A.; Maal, T.J.J.; Berge, S.J.; Kuijpers-Jagtman, A.M.

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all

  7. Measurement of mesothelioma on thoracic CT scans: A comparison of manual and computer-assisted techniques

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Oxnard, Geoffrey R.; MacMahon, Heber; Vogelzang, Nicholas J.; Kindler, Hedy L.; Kocherginsky, Masha; Starkey, Adam

    2004-01-01

    Our purpose in this study was to evaluate the variability of manual mesothelioma tumor thickness measurements in computed tomography (CT) scans and to assess the relative performance of six computerized measurement algorithms. The CT scans of 22 patients with malignant pleural mesothelioma were collected. In each scan, an initial observer identified up to three sites in each of three CT sections at which tumor thickness measurements were to be made. At each site, five observers manually measured tumor thickness through a computer interface. Three observers repeated these measurements during three separate sessions. Inter- and intra-observer variability in the manual measurement of tumor thickness was assessed. Six automated measurement algorithms were developed based on the geometric relationship between a specified measurement site and the automatically extracted lung regions. Computer-generated measurements were compared with manual measurements. The tumor thickness measurements of different observers were highly correlated (r≥0.99); however, the 95% limits of agreement for relative inter-observer difference spanned a range of 30%. Tumor thickness measurements generated by the computer algorithms also correlated highly with the average of observer measurements (r≥0.93). We have developed computerized techniques for the measurement of mesothelioma tumor thickness in CT scans. These techniques achieved varying levels of agreement with measurements made by human observers

  8. Regimes of data output from an automated scanning system into a computer

    International Nuclear Information System (INIS)

    Ovsov, Yu.V.; Shaislamov, P.T.

    1984-01-01

    A method is described for accomplishment of rather a complex algorithm of various coordinate and service data transmission from different automated scanning system devices into a monitoring computer in the automated system for processing images from bubble chambers. The accepted data output algorithm and the developed appropriate equipment enable data transmission both in separate words and word arrays

  9. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan

    NARCIS (Netherlands)

    Hassan, B.; Metska, M.E.; Özok, A.R.; van der Stelt, P.; Wesselink, P.R.

    2009-01-01

    Our aim was to compare the accuracy of cone beam computed tomography (CBCT) scans and periapical radiographs (PRs) in detecting vertical root fractures (VRFs) and to assess the influence of root canal filling (RCF) on fracture visibility. Eighty teeth were endodontically prepared and divided into

  10. Volume adjustment of lung density by computed tomography scans in patients with emphysema

    DEFF Research Database (Denmark)

    Shaker, S B; Dirksen, A; Laursen, Lars Christian

    2004-01-01

    of pulmonary emphysema derived from CT scans. These parameters are markedly influenced by changes in the level of inspiration. The variability of lung density due to within-subject variation in TLV was explored by plotting TLV against PD and RA. RESULTS: The coefficients for volume adjustment for PD were...... relatively stable over a wide range from the 10th to the 80th percentile, whereas for RA the coefficients showed large variability especially in the lower range, which is the most relevant for quantitation of pulmonary emphysema. CONCLUSION: Volume adjustment is mandatory in repeated CT densitometry......PURPOSE: To determine how to adjust lung density measurements for the volume of the lung calculated from computed tomography (CT) scans in patients with emphysema. MATERIAL AND METHODS: Fifty patients with emphysema underwent 3 CT scans at 2-week intervals. The scans were analyzed with a software...

  11. Clinical study on eating disorders. Brain atrophy revealed by cranial computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Nishiwaki, Shinichi

    1988-06-01

    Cranial computed tomography (CT) scans were reviewed in 34 patients with anorexia nervosa (Group I) and 22 with bulimia (Group II) to elucidate the cause and pathological significance of morphological brain alterations. The findings were compared with those from 47 normal women. The incidence of brain atrophy was significantly higher in Group I (17/34, 50%) and Group II (11/22, 50%) than the control group (3/47, 6%). In Group I, there was a significant increase in the left septum-caudate distance, the maximum width of interhemispheric fissure, the width of the both-side Sylvian fissures adjacent to the skull, and the maximum width of the third ventricle. A significant increase in the maximum width of interhemispheric fissure and the width of the left-side Sylvian fissure adjacent to the skull were noted as well in Group II. Ventricular brain ratios were significantly higher in Groups I and II than the control group (6.76 and 7.29 vs 4.55). Brain atrophy did not correlate with age, body weight, malnutrition, eating behavior, depression, thyroid function, EEG findings, or intelligence scale. In Group I, serum cortisol levels after the administration of dexamethasone were correlated with ventricular brain ratio. (Namekawa, K) 51 refs.

  12. Clinical Symptoms of Minor Head Trauma and Abnormal Computed Tomography Scan

    Directory of Open Access Journals (Sweden)

    Maghsoudi

    2015-11-01

    Full Text Available Background Minor head trauma accounts for 70% to 90% of all head traumas. Previous studies stated that minor head traumas were associated with 7% - 20% significant abnormal findings in brain computed tomography (CT-scans. Objectives The aim of this study was to reevaluate clinical criteria of taking brain CT scan in patients who suffered from minor head trauma. Patients and Methods We enrolled 680 patients presented to an academic trauma hospital with minor head trauma in a prospective manner. All participants underwent brain CT scan if they met the inclusion criteria and the results of scans were compared with clinical examination finding. Results Loss of consciousness (GCS drop or amnesia was markedly associated with abnormal brain CT scan (P < 0.05. Interestingly, we found 7 patients with normal clinical examination but significant abnormal brain CT scan. Conclusions According to the results of our study, we recommend that all patients with minor head trauma underwent brain CT scan in order not to miss any life-threatening head injuries.

  13. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans.

    Science.gov (United States)

    Ritchie, Alexander J; Sanghera, Calvin; Jacobs, Colin; Zhang, Wei; Mayo, John; Schmidt, Heidi; Gingras, Michel; Pasian, Sergio; Stewart, Lori; Tsai, Scott; Manos, Daria; Seely, Jean M; Burrowes, Paul; Bhatia, Rick; Atkar-Khattra, Sukhinder; van Ginneken, Bram; Tammemagi, Martin; Tsao, Ming Sound; Lam, Stephen

    2016-05-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in which a technician assisted by computer vision (CV) software acts as a first reader with the aim to improve speed, consistency, and quality of scan interpretation. Without knowledge of the diagnosis, a technician reviewed 828 randomly batched scans (136 with lung cancers, 556 with benign nodules, and 136 without nodules) from the baseline Pan-Canadian Early Detection of Lung Cancer Study that had been annotated by the CV software CIRRUS Lung Screening (Diagnostic Image Analysis Group, Nijmegen, The Netherlands). The scans were classified as either normal (no nodules ≥1 mm or benign nodules) or abnormal (nodules or other abnormality). The results were compared with the diagnostic interpretation by Pan-Canadian Early Detection of Lung Cancer Study radiologists. The overall sensitivity and specificity of the technician in identifying an abnormal scan were 97.8% (95% confidence interval: 96.4-98.8) and 98.0% (95% confidence interval: 89.5-99.7), respectively. Of the 112 prevalent nodules that were found to be malignant in follow-up, 92.9% were correctly identified by the technician plus CV compared with 84.8% by the study radiologists. The average time taken by the technician to review a scan after CV processing was 208 ± 120 seconds. Prescreening CV software and a technician as first reader is a promising strategy for improving the consistency and quality of screening interpretation of LDCT scans. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  14. Design of scanning motion control system for high-energy X-ray industrial CT

    International Nuclear Information System (INIS)

    Duan Liming

    2008-01-01

    A scanning motion control system was developed for the high-energy X-ray industrial computerized tomography (CT). The system consists of an industrial control computer, a counter card, a control card, servo drivers, servo motors, working platforms, gratings and control software. Based on windows driver model(WDM) mode, the composition of the driver pro- gram for the system was studied. Took the motor control card as an example, the method to develop the driver program was researched, and the intercourse process between the device driver program and the user-program was analyzed. The real-time control of the system was implemented using the WDM driver. The real-time performance and reliability of the system can satisfy the requirement of high-energy X-ray industrial CT. (authors)

  15. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    International Nuclear Information System (INIS)

    Tanaka, Hiroshi

    1988-01-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development. (author)

  16. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning, 2

    International Nuclear Information System (INIS)

    Uchiyama, Mayuki; Tanaka, Hiroshi; Harada, Junta

    1992-01-01

    Computed tomography was performed on 104 patients with cleft lip and palate by continuous 2 mm slice scanning. The type of hard palate was classified as normal, hypoplasia and aplasia, depending on its developmental degree. The shape of alveolus was also classified as circular, triangular and asymmetric forms for the evaluation of the maxillary development. The hard palate development correlated with the shape of the alveolus, the diameter of maxillary and mandibular bone, and frequency of sinusitis and otitis media. Evaluation of the hard palate by thin slice scanning is useful in presumption of future fecial development. (author)

  17. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiroshi

    1988-07-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development.

  18. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning, 2

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, Mayuki; Tanaka, Hiroshi; Harada, Junta (Jikei Univ., Tokyo (Japan). School of Medicine)

    1992-06-01

    Computed tomography was performed on 104 patients with cleft lip and palate by continuous 2 mm slice scanning. The type of hard palate was classified as normal, hypoplasia and aplasia, depending on its developmental degree. The shape of alveolus was also classified as circular, triangular and asymmetric forms for the evaluation of the maxillary development. The hard palate development correlated with the shape of the alveolus, the diameter of maxillary and mandibular bone, and frequency of sinusitis and otitis media. Evaluation of the hard palate by thin slice scanning is useful in presumption of future fecial development. (author).

  19. Computer-assisted sequential quantitative analysis of gallium scans in pulmonary sarcoidosis

    International Nuclear Information System (INIS)

    Rohatgi, P.K.; Bates, H.R.; Noss, R.W.

    1985-01-01

    Fifty-one sequential gallium citrate scans were performed in 22 patients with biopsy-proven sarcoidosis. A computer-assisted quantitative analysis of these scans was performed to obtain a gallium score. The changes in gallium score were correlated with changes in serum angiotensin converting enzyme (SACE) activity and objective changes in clinical status. There was a good concordance between changes in gallium score, SACE activity and clinical assessment in patients with sarcoidosis, and changes in gallium index were slightly superior to SACE index in assessing activity of sarcoidosis. (author)

  20. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  1. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  2. What Can Computed Tomography Scans of the Thorax Show after Breast Surgery?

    Directory of Open Access Journals (Sweden)

    Afsaneh Alikhassi

    2016-06-01

    Full Text Available Background: Postoperative breast abnormalities after breast conserving surgery or modified radical mastectomy are frequently overlooked and inaccurately assessed or reported using multidetector computed tomography (MDCT. These inaccurate results may have legal ramifications for the clinicians, cause patients avoidable anxiety, and lead to additional unnecessary diagnostic follow-up testing and costs.Methods: The patients with a history of breast cancer who had undergone breast-conserving surgery or modified radical mastectomy up to 6 months prior to undergoing a thoracic MDCT scan consented and enrolled in this study. These patients underwent a thoracic MDCT scan either because of respiratory or cardiac clinical symptoms or as part of breast cancer staging.Results: Forty women were included in this study. Different postoperative breast changes observed on thoracic MDCT scans including fibrous scar tissue, fat necrosis, seroma, abscess, hematoma, and recurrent and residual tumor were described.Conclusions: MDCT scans offer sufficient evidence in many postoperative cases to allow a confident diagnosis. General radiologists who review thoracic MDCT scans should know how to characterize breast lesions incidentally found on MDCT scans after breast surgeries. This information would enhance the value of the radiologist’s report for appropriate case management.

  3. Integration of Digital Dental Casts in Cone-Beam Computed Tomography Scans

    Science.gov (United States)

    Rangel, Frits A.; Maal, Thomas J. J.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all reported methods have drawbacks. The aim of this feasibility study is to present a new simplified method to integrate digital dental casts into CBCT scans. In a patient scheduled for orthognathic surgery, titanium markers were glued to the gingiva. Next, a CBCT scan and dental impressions were made. During the impression-taking procedure, the titanium markers were transferred to the impression. The impressions were scanned, and all CBCT datasets were exported in DICOM format. The two datasets were matched, and the dentition derived from the scanned impressions was transferred to the CBCT of the patient. After matching the two datasets, the average distance between the corresponding markers was 0.1 mm. This novel method allows for the integration of digital dental casts into CBCT scans, overcoming problems such as unwanted extra radiation exposure, distortion of soft tissues due to the use of bite jigs, and time-consuming digital data handling. PMID:23050159

  4. Local annealing of shape memory alloys using laser scanning and computer vision

    Science.gov (United States)

    Hafez, Moustapha; Bellouard, Yves; Sidler, Thomas C.; Clavel, Reymond; Salathe, Rene-Paul

    2000-11-01

    A complete set-up for local annealing of Shape Memory Alloys (SMA) is proposed. Such alloys, when plastically deformed at a given low temperature, have the ability to recover a previously memorized shape simply by heating up to a higher temperature. They find more and more applications in the fields of robotics and micro engineering. There is a tremendous advantage in using local annealing because this process can produce monolithic parts, which have different mechanical behavior at different location of the same body. Using this approach, it is possible to integrate all the functionality of a device within one piece of material. The set-up is based on a 2W-laser diode emitting at 805nm and a scanner head. The laser beam is coupled into an optical fiber of 60(mu) in diameter. The fiber output is focused on the SMA work-piece using a relay lens system with a 1:1 magnification, resulting in a spot diameter of 60(mu) . An imaging system is used to control the position of the laser spot on the sample. In order to displace the spot on the surface a tip/tilt laser scanner is used. The scanner is positioned in a pre-objective configuration and allows a scan field size of more than 10 x 10 mm2. A graphical user interface of the scan field allows the user to quickly set up marks and alter their placement and power density. This is achieved by computer controlling X and Y positions of the scanner as well as the laser diode power. A SMA micro-gripper with a surface area less than 1 mm2 and an opening of the jaws of 200(mu) has been realized using this set-up. It is electrically actuated and a controlled force of 16mN can be applied to hold and release small objects such as graded index micro-lenses at a cycle time of typically 1s.

  5. THE INTEGRATED USE OF COMPUTATIONAL CHEMISTRY, SCANNING PROBE MICROSCOPY, AND VIRTUAL REALITY TO PREDICT THE CHEMICAL REACTIVITY OF ENVIRONMENTAL SURFACES

    Science.gov (United States)

    In the last decade three new techniques scanning probe microscopy (SPM), virtual reality (YR) and computational chemistry ave emerged with the combined capability of a priori predicting the chemically reactivity of environmental surfaces. Computational chemistry provides the cap...

  6. Dose profile in computed tomography chest scan; Perfil de dose em varredura de torax em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno B., E-mail: bbo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais; Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil); Alonso, Thessa C.; Silva, Teogenes A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2010-07-01

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58{+-}5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  7. COMPUTER CONTROL OF BEHAVIORAL EXPERIMENTS.

    Science.gov (United States)

    SIEGEL, LOUIS

    THE LINC COMPUTER PROVIDES A PARTICULAR SCHEDULE OF REINFORCEMENT FOR BEHAVIORAL EXPERIMENTS BY EXECUTING A SEQUENCE OF COMPUTER OPERATIONS IN CONJUNCTION WITH A SPECIALLY DESIGNED INTERFACE. THE INTERFACE IS THE MEANS OF COMMUNICATION BETWEEN THE EXPERIMENTAL CHAMBER AND THE COMPUTER. THE PROGRAM AND INTERFACE OF AN EXPERIMENT INVOLVING A PIGEON…

  8. Development of scan analysis techniques employing a small computer. Progress report, August 1, 1974--July 31, 1975

    International Nuclear Information System (INIS)

    Kuhl, D.E.

    1975-01-01

    Progress is reported in the development of equipment and counting techniques for transverse section scanning of the brain following the administration of radiopharmaceuticals to evaluate regional blood flow. The scanning instrument has an array of 32 scintillation detectors that surround the head and scan data are analyzed using a small computer. (U.S.)

  9. Remote control scanning electron microscope with Web operation

    International Nuclear Information System (INIS)

    Yamada, A.; Hirahara, O.; Date, M.; Lozbin, V.; Tsuchida, T.; Sugano, N.

    2002-01-01

    Full text: Recently, SEM (Scanning Electron Microscope) and the other observation instruments are coming to use a LAN (Local Area Network) to save the image in the database. We developed a remote control system in which SEM image and Control interface is indicated on the WEB Browser. In this system, SEM can be controlled by an external (client) PC installed in a general WEB Browser (Internet Explorer). Accordingly, operation interface can be indicated on the WEB browser. A JSM-6700F is connected to a LAN, and so a client PC can control the microscope. The JSM-6700F has two lines to the LAN for image transfer and communication with the SEM control. In order to transfer the image, the image size squeezes from 1280 x 1024-pixels (SEM image size) to 640x480-pixels for quick transfer. The image signal (640 x 480-pixels) is connected to the video server only, and then the image transfers to the client PC via LAN. The SEM control communicates with client PC for external command. On the other hand, the SEM control interface and the image are indicated on WEB Browser (Internet explorer). The SEM control interface is composed of the SEM image area and the SEM control part. The SEM image indicates the 640x480-pixels live image. This live image is being used as a high resolution live image transfer in the image transfer technology which a network is used for at present. If it is LAN beyond 10 base, this indication of an image can be transferred fully. When it is connected in the small line of the capacity, the refresh speed of the image becomes slow because of image data doesn't finish transferring it. In such a case, image size can be changed smaller by the LAN conditions. When a high quality image is necessary, the image of 1280 x 1024-pixels is saved on a SEM (server) side by choosing the image save button. At the same time, the file kept in SEM (server) is transferred to the client PC automatically, so that we can display a high quality image on the client PC side. The

  10. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system

    Science.gov (United States)

    das Neves, Flávio Domingues; de Almeida Prado Naves Carneiro, Thiago; do Prado, Célio Jesus; Prudente, Marcel Santana; Zancopé, Karla; Davi, Letícia Resende; Mendonça, Gustavo; Soares, Carlos José

    2014-08-01

    The current study evaluated prosthetic dental crowns obtained by optical scanning and a computer-aided designing/computer-aided manufacturing system using micro-computed tomography to compare the marginal fit. The virtual models were obtained with four different scanning surfaces: typodont (T), regular impressions (RI), master casts (MC), and powdered master casts (PMC). Five virtual models were obtained for each group. For each model, a crown was designed on the software and milled from feldspathic ceramic blocks. Micro-CT images were obtained for marginal gap measurements and the data were statistically analyzed by one-way analysis of variance followed by Tukey's test. The mean vertical misfit was T=62.6±65.2 μm; MC=60.4±38.4 μm; PMC=58.1±38.0 μm, and RI=89.8±62.8 μm. Considering a percentage of vertical marginal gap of up to 75 μm, the results were T=71.5%, RI=49.2%, MC=69.6%, and PMC=71.2%. The percentages of horizontal overextension were T=8.5%, RI=0%, MC=0.8%, and PMC=3.8%. Based on the results, virtual model acquisition by scanning the typodont (simulated mouth) or MC, with or without powder, showed acceptable values for the marginal gap. The higher result of marginal gap of the RI group suggests that it is preferable to scan this directly from the mouth or from MC.

  11. Design and application of the MARK IV scanning system for radionuclide computed tomography of the brain

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Hoffman, E.J.; Phelps, M.E.; Ricci, A.; Reivich, M.

    1976-01-01

    The MARK IV radioisotope scanning system was built to provide fast and accurate radionuclide computed tomography (RCT). It is designed primarily for detecting commonly available radioactive labels such as /sup 99m/Tc, but it is also adapted to detecting positron emitters such as 18 F. The system has interlaced convergent collimation in a 4-sided arrangement of 32-independent detectors which continuously rotate as a unit, detecting, processing, and displaying the reconstructed data while the study progresses

  12. Underdiagnosis of Vertebral Collapse on Routine Multidetector Computed Tomography Scan of the Abdomen

    International Nuclear Information System (INIS)

    Obaid, H.; Husamaldin, Z.; Bhatt, R.

    2008-01-01

    Background: Vertebral fractures are commonly associated with osteoporosis and have significant morbidity and mortality rates. Osteoporotic vertebral fractures are presently considered as a treatable and preventable condition, and early detection is vital for further management. The evaluation of vertebral compression on multidetector computed tomography (MDCT) scans of the abdomen has, to our knowledge, not been reported before. Purpose: To assess the prevalence of vertebral collapse on routine abdominal CT scans, and to evaluate the usefulness of the multiplanar reconstruction (MPR) capability of MDCT scans in accurately identifying vertebral abnormalities such as vertebral collapse, spondylolisthesis, and retrolisthesis. Material and Methods: A retrospective review of 307 MDCT scans of the abdomen was carried out at a university teaching hospital. Identifiable patient information was anonymized for data protection. All images were reviewed on a picture archiving and communications system (PACS) using sagittal MPR and bone window for the assessment of the vertebrae. Data were collected from the Computerized Radiology Information System (CRIS). Results: Vertebral collapse was seen in 42 (13.6%) of the 307 patients undergoing routine MDCT of the abdomen. Multilevel and single-level collapses were seen in 24 and 18 patients, respectively. Spondylolisthesis was identified in 5.5% (n=17), and retrolisthesis was seen in 0.6% (n=2). All patients with vertebral fracture were older than 50 years. Women were more commonly affected than men. Conclusion: A significant number of patients with vertebral collapse were diagnosed using MPR on MDCT routine scans of the abdomen

  13. Computer control of shielded cell operations

    International Nuclear Information System (INIS)

    Jeffords, W.R. III.

    1987-01-01

    This paper describes in detail a computer system to remotely control shielded cell operations. System hardware, software, and design criteria are discussed. We have designed a computer-controlled buret that provides a tenfold improvement over the buret currently in service. A computer also automatically controls cell analyses, calibrations, and maintenance. This system improves conditions for the operators by providing a safer, more efficient working environment and is expandable for future growth and development

  14. Automated Agatston score computation in non-ECG gated CT scans using deep learning

    Science.gov (United States)

    Cano-Espinosa, Carlos; González, Germán.; Washko, George R.; Cazorla, Miguel; San José Estépar, Raúl

    2018-03-01

    Introduction: The Agatston score is a well-established metric of cardiovascular disease related to clinical outcomes. It is computed from CT scans by a) measuring the volume and intensity of the atherosclerotic plaques and b) aggregating such information in an index. Objective: To generate a convolutional neural network that inputs a non-contrast chest CT scan and outputs the Agatston score associated with it directly, without a prior segmentation of Coronary Artery Calcifications (CAC). Materials and methods: We use a database of 5973 non-contrast non-ECG gated chest CT scans where the Agatston score has been manually computed. The heart of each scan is cropped automatically using an object detector. The database is split in 4973 cases for training and 1000 for testing. We train a 3D deep convolutional neural network to regress the Agatston score directly from the extracted hearts. Results: The proposed method yields a Pearson correlation coefficient of r = 0.93; p <= 0.0001 against manual reference standard in the 1000 test cases. It further stratifies correctly 72.6% of the cases with respect to standard risk groups. This compares to more complex state-of-the-art methods based on prior segmentations of the CACs, which achieve r = 0.94 in ECG-gated pulmonary CT. Conclusions: A convolutional neural network can regress the Agatston score from the image of the heart directly, without a prior segmentation of the CACs. This is a new and simpler paradigm in the Agatston score computation that yields similar results to the state-of-the-art literature.

  15. Investigation of optimal scanning protocol for X-ray computed tomography polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Sellakumar, P. [Bangalore Institute of Oncology, 44-45/2, II Cross, RRMR Extension, Bangalore 560 027 (India)], E-mail: psellakumar@rediffmail.com; James Jebaseelan Samuel, E. [School of Science and Humanities, VIT University, Vellore 632 014 (India); Supe, Sanjay S. [Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Hosur Road, Bangalore 560 027 (India)

    2007-11-15

    X-ray computed tomography is one of the potential tool used to evaluate the polymer gel dosimeters in three dimensions. The purpose of this study is to investigate the factors which affect the image noise for X-ray CT polymer gel dosimetry. A cylindrical water filled phantom was imaged with single slice Siemens Somatom Emotion CT scanner. The imaging parameters like tube voltage, tube current, slice scan time, slice thickness and reconstruction algorithm were varied independently to study the dependence of noise on each other. Reductions of noise with number of images to be averaged and spatial uniformity of the image were also investigated. Normoxic polymer gel PAGAT was manufactured and irradiated using Siemens Primus linear accelerator. The radiation induced change in CT number was evaluated using X-ray CT scanner. From this study it is clear that image noise is reduced with increase in tube voltage, tube current, slice scan time, slice thickness and also reduced with increasing the number of images averaged. However to reduce the tube load and total scan time, it was concluded that tube voltage of 130 kV, tube current of 200 mA, scan time of 1.5 s, slice thickness of 3 mm for high dose gradient and 5 mm for low dose gradient were optimal scanning protocols for this scanner. Optimum number of images to be averaged was concluded to be 25 for X-ray CT polymer gel dosimetry. Choice of reconstruction algorithm was also critical. From the study it is also clear that CT number increase with imaging tube voltage and shows the energy dependency of polymer gel dosimeter. Hence for evaluation of polymer gel dosimeters with X-ray CT scanner needs the optimization of scanning protocols to reduce the image noise.

  16. Interactive scan control for kinematic study in open MRI

    International Nuclear Information System (INIS)

    Goto, Tomohiro; Hamada, Kiyomi; Ito, Taeko; Nagao, Hisako; Takahashi, Tetsuhiko; Hayashida, Yoshiko; Hiai, Yasuhiro; Yamashita, Yasuyuki

    2007-01-01

    A tool to support the subject is generally used for kinematic joint imaging with an open MRI apparatus because of difficulty setting the image plane correctly. However, use of a support tool requires a complicated procedure to position the subject, and setting the image plane when the joint angle changes is time consuming. Allowing the subject to move freely enables better diagnoses when kinematic joint imaging is performed. We therefore developed an interactive scan control (ISC) to facilitate the easy, quick, and accurate setting of the image plane even when a support tool is not used. We used a 0.4T magnetic resonance (MR) imaging system open in the horizontal direction. The ISC determines the image plane interactively on the basis of fluoroscopy images displayed on a user interface. The imaging pulse is a balanced steady-state acquisition with rewound gradient echo (SARGE) sequence with update time less than 2 s. Without using a tool to support the knee, we positioned the knee of a healthy volunteer at 4 different joint angles and set the image plane through the patella and femur at each of the angles. Lumbar imaging is also demonstrated with ISC. Setting the image plane was easy and quick at all knee angles, and images obtained clearly showed the patella and femur. Total imaging time was less than 10 min, a fourth of the time needed when a support tool is used. We also used our ISC in kinematic imaging of the lumbar. The ISC shortens total time for kinematic joint imaging, and because a support tool is not needed, imaging can be done more freely in an open MR imaging apparatus. (author)

  17. Computer aided detection system for lung cancer using computer tomography scans

    Science.gov (United States)

    Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.

    2018-04-01

    Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.

  18. A History of Computer Numerical Control.

    Science.gov (United States)

    Haggen, Gilbert L.

    Computer numerical control (CNC) has evolved from the first significant counting method--the abacus. Babbage had perhaps the greatest impact on the development of modern day computers with his analytical engine. Hollerith's functioning machine with punched cards was used in tabulating the 1890 U.S. Census. In order for computers to become a…

  19. Abdominal fat-evaluation by use of single scan computed tomography

    International Nuclear Information System (INIS)

    Jacobi, V.; Steinkamp, M.; Kirchner, J.; Fischer, H.; Diedrich, C.F.; Kollath, J.

    1997-01-01

    Purpose: Several studies emphasised the importance of the relationship between intraabdominal and total body adipose tissue as a risk factor for the development of metabolic or cardiovascular diseases. Therefore, the aim of the present study was to examine whether a single scan computed tomography is able to determine the whole intraabdominal fat volume with high accuracy and reproducibility. Materials and methods: Regions of interests (ROIs) were drawn manually for measuring intraabdominal fat in 51 unsuspicious abdominal CT. Results: The sexual differentiation of adipose tissue already described in a lot of studies could be confirmed in this study. Fat still predominates in females in lower half of the body (gynoid obesity). In men it predominates in the upper half (android obesity). Significant correlation concerning measuring the whole intraabdominal fat volume could be found in L1-level in women (r=0.992) and in L2-level in men (r=0.992). Measurement of a single scan enables us to assess whole intraabdominal fat volume due to a special formula. Conclusion: The determination of intraabdominal fat measured by a single scan computed tomography is a procedure associated with high accuracy and reproducibility. (orig.) [de

  20. Volume Adjustment of Lung Density by Computed Tomography Scans in Patients with Emphysema

    International Nuclear Information System (INIS)

    Shaker, S.B.; Dirksen, A.; Laursen, L.C.; Skovgaard, L.T.; Holstein-Rathlou, N.H.

    2004-01-01

    Purpose: To determine how to adjust lung density measurements for the volume of the lung calculated from computed tomography (CT) scans in patients with emphysema. Material and Methods: Fifty patients with emphysema underwent 3 CT scans at 2-week intervals. The scans were analyzed with a software package that detected the lung in contiguous images and subsequently generated a histogram of the pixel attenuation values. The total lung volume (TLV), lung weight, percentile density (PD), and relative area of emphysema (RA) were calculated from this histogram. RA and PD are commonly applied measures of pulmonary emphysema derived from CT scans. These parameters are markedly influenced by changes in the level of inspiration. The variability of lung density due to within-subject variation in TLV was explored by plotting TLV against PD and RA. Results: The coefficients for volume adjustment for PD were relatively stable over a wide range from the 10th to the 80th percentile, whereas for RA the coefficients showed large variability especially in the lower range, which is the most relevant for quantitation of pulmonary emphysema. Conclusion: Volume adjustment is mandatory in repeated CT densitometry and is more robust for PD than for RA. Therefore, PD seems more suitable for monitoring the progression of emphysema

  1. Glycosaminoglycan, computed tomography and gallium-67 scanning in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Nakano, Takashi; Fujii, Junji; Yamakawa, Kiyohiro; Tamura, Shinsuke; Amuro, Yoshiki; Nabeshima, Kenji; Hada, Toshikazu; Higashino, Kazuya; Horai, Takeshi.

    1985-01-01

    Malignant pleural mesothelioma is an unusual disease, often difficult to diagnose. This paper describes the results of quantitative studies on glycosaminoglycan (GAG) in tumor tissues and the findings of chest computed tomography (CT) and gallium-67 scanning in 5 malignant pleural mesotheliomas. The total amount of GAG in tumor tissue was 2.3 to 17.0 times as high as that in adenocarcinoma of the lung. The amount of hyaluronic acid was 3.5 to 170 times higher than that in adenocarcinoma. Also, the amount of chondroitin sulfate increased 2.6 to 10.0 times, but there were no changes in dermatan sulfate and heparan sulfate contents in this neoplasm when compared with adenocarcinoma. The present study suggests that a marked increase of the total amount of GAG and elevation of either hyaluronic acid and chondroitin sulfate content or both is a characteristic abnormality in this neoplasm. In most cases, CT scan of the chest showed pleural effusion, irregular pleural tumorous thickening surrounding the whole lung surface and extension into the fissure. In 3 cases, tumorous lesions extending into the chest wall at the site of pleural biopsy could be visualized on CT. In the terminal stage, the thoracic cavity was occupied by tumor tissues. Gallium-67 scanning showed a diffusely increased radionuclide accumulation over the involved hemithorax with or without particular intensity in the periphery. Conversely, identification of these characteristic findings of CT and gallium-67 scanning indicates the possibility of malignant pleural mesothelioma. (author)

  2. A computer controlled tele-cobalt unit

    International Nuclear Information System (INIS)

    Brace, J.A.

    1982-01-01

    A computer controlled cobalt treatment unit was commissioned for treating patients in January 1980. Initially the controlling computer was a minicomputer, but now the control of the therapy unit is by a microcomputer. The treatment files, which specify the movement and configurations necessary to deliver the prescribed dose, are produced on the minicomputer and then transferred to the microcomputer using minitape cartridges. The actual treatment unit is based on a standard cobalt unit with a few additional features e.g. the drive motors can be controlled either by the computer or manually. Since the treatment unit is used for both manual and automatic treatments, the operational procedure under computer control is made to closely follow the manual procedure for a single field treatment. The necessary safety features which protect against human, hardware and software errors as well as the advantages and disadvantages of computer controlled radiotherapy are discussed

  3. Logical design for computers and control

    CERN Document Server

    Dodd, Kenneth N

    1972-01-01

    Logical Design for Computers and Control Logical Design for Computers and Control gives an introduction to the concepts and principles, applications, and advancements in the field of control logic. The text covers topics such as logic elements; high and low logic; kinds of flip-flops; binary counting and arithmetic; and Boolean algebra, Boolean laws, and De Morgan's theorem. Also covered are topics such as electrostatics and atomic theory; the integrated circuit and simple control systems; the conversion of analog to digital systems; and computer applications and control. The book is recommend

  4. Computed tomographic scanning in patients presenting with chief complaint of headache without focal neurological signs

    International Nuclear Information System (INIS)

    Halim, A.; Khalid, W.; Haq, A.U.

    2017-01-01

    To determine the frequency of positive computed tomographic (CT)scan findings in patients presenting at PNS Shifa Hospital Karachi with chief complaint of headache without focal neurological signs. Study Design: Cross sectional descriptive study. Place and Duration of Study: The study was conducted at the Radiology department, PNS Shifa Hospital Karachi from Dec 2011 to Jun 2012. Patients and Methods: This cross-sectional descriptive study included referred patients with complaint of headache of one month duration or more without focal neurological signs. No gender restriction was considered and patients of age more than 14 years were included. Patients with headache due to other known clinical disorders such as intracranial neoplasm and stroke were excluded. Patients with focal neurological signs such as hemiparesis, cerebellar signs and cranial nerve palsies were also excluded from the study. A total of 105 patients were included in the study through non probability consecutive sampling. Informed written consent was taken from the patients by explaining all the risks and benefits of the study and use of data for research and publication. Plain CT scan brain was done by trained CT technician and reporting of CT scan was done by consultant radiologist. CT scan was done on Toshiba Scanner Aquilion-64 CT Scan machine. The imaging protocol consisted of appropriately angled continuous 5mm thick axial slices for the posterior fossa and 10 mm thick slices for the rest of brain from the base of skull to the vertex. Data was collected through a specially structured proforma. Confidentiality of the patients record was maintained. Results: Majority of the patients were between 31-40 years of age i.e. 29.52 percent (n=31) and mean and SD was calculated as 34.24 +- 8.72 years, 54.29 percent (n=57) females and 45.71 percent (n=48) male patients, frequency of positive CT scan findings in patients with chief complaint of headache without focal neurological signs was recorded as

  5. Whole-heart 320-row computed tomography. Reduction of radiation dose via prior coronary calcium scanning

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, E.; Dewey, M. [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-01-15

    Purpose: The whole heart can be scanned in one rotation using 320-row coronary computed tomography angiography (CCTA), which covers up to 16 cm. Since most hearts are smaller, the total radiation dose may be reduced by adjusting the CCTA range to the individual heart size defined on a low-dose calcium scan (CACS). Materials and Methods: Forty-five patients with suspected coronary artery disease (13 women, 32 men; mean 61 {+-} 10 years) underwent CCTA preceded by low-dose CACS on a 320-row scanner (Aquilion ONE, Toshiba; 0.35 s gantry rotation, 120 kV, 350 - 450 mA) with 16-cm z-axis coverage (120 kV, 150 mA). The subsequent CCTA was performed over an adjusted scan range calculated as the individual heart size on CACS ({+-} 1 cm above and below). The total radiation dose of 16-cm CACS and the individually adjusted CCTA was compared with that of a calculated single CCTA using full 16-cm z-axis coverage. Results: CCTA could be performed with a reduced scan length in the z-axis in all patients. None of the scans had to be performed over the whole range of 16 cm. The adjusted scan length was 14 cm in 2 patients, 12.8 cm in 3 patients, and 12 cm in 40 patients. The effective CCTA scan range was 12.1 {+-} 0.5 cm based on mean individual heart sizes of 9.6 {+-} 1.1 cm. The mean total effective radiation dose of the entire cardiac CT examination (individually adapted CCTA and CACS) was significantly smaller than the exposure calculated for 16-cm CCTA without CACS (8.5 {+-} 4.7 vs. 9.1 {+-} 6.0 mSv, p = 0.006). The dose reduction was most relevant in patients with heart rates above 65 beats/min (n = 10) in whom 2 or 3 heartbeats were necessary for CCTA (17.7 {+-} 6.5 vs. 21.1 {+-} 8.4 mSv, p = 0.001). Conclusion: 320-row CCTA with an individually adjusted scan range based on prior CACS significantly reduces the radiation exposure compared with full 16-cm CCTA. (orig.)

  6. Dual-scan technique for the customization of zirconia computer-aided design/computer-aided manufacturing frameworks.

    Science.gov (United States)

    Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes

    2013-09-01

    The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.

  7. Estimation of MSAD values in computed tomography scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno Beraldo; Teogenes Augusto da, E-mail: bbo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Mourao, Arnaldo Prata [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2013-03-15

    Objective: To evaluate the feasibility of using radiochromic films as an alternative dosimeter to estimate the multiple scan average dose on the basis on kerma profiles. Materials and Methods: The radiochromic films were distributed in cylinders positioned in the center and in four peripheral bores of a standard abdominal phantom utilized for computed tomography dosimetry. Results: Values for multiple scan average dose values corresponded to 13.6 {+-} 0.7, 13.5 {+-} 0.7 and 18.7 {+-} 1.0 mGy for pitch of 0.75, 1.00 and 1.50, respectively. Conclusion: In spite of results showing lower values than the reference level for radiodiagnosis (25 mGy) established by the Brazilian regulations for abdominal studies, it is suggested that there is room to optimize procedures and review the reference level for radiodiagnosis in Brazil. (author)

  8. Comparison of radionuclide scans with computer-assisted tomography in diagnosis of intracranial disease

    International Nuclear Information System (INIS)

    Clifford, J.R.; Connolly, E.S.; Voorhies, R.M.

    1976-01-01

    Radionuclide brain scans were compared with computer-assisted tomography (CAT) for the diagnosis of intracranial disorders in 297 patients. The diagnosis was confirmed in 281 patients who formed the population for the study. The radionuclide scan was false positive for 12 patients (3.9 percent) and false negative for eight (2.6 percent). The CAT was false positive for three patients (1 percent) and false negative for one (0.3 percent). In the 133 patients in whom both tests were negative, no evidence of central nervous system pathology has been found during the 6 to 18 month follow-up. Brain tumors and intracerebral hemorrhage are more readily detectable with CAT

  9. Static and dynamic 3 dimensional studies of water in soil using computed tomographic scanning

    International Nuclear Information System (INIS)

    Crestana, S.; Mascarenhas, S.; Pozzi-Mucelli, R.S.

    1984-03-01

    Previous work of Petrovic, Siebert and Rieke demonstrated the possibility of using X-ray transmission computed tomography (CT) scanning for soil bulk density analysis in soil. We show in the present work that CT can also be used for the measurement of water content in soil. In our case we also show that CT can be applied to measure and follow dynamically the motion of water in soil in 3-dimensions. Further, more inhomogeneities of water content and motion in soil can be observed with this technique. Using a third generation CT scanner several different techniques can be applied such as differential, real time and spatial distribution scanning modes. A linear dependence was demonstrated for the Hounsfield Units (HU) used in CT and water content. The use of CT for water content and motion in soil in 3-dimensions opens new possibilities in this area of investigations. (author)

  10. Digitally controlled analog proportional-integral-derivative (PID) controller for high-speed scanning probe microscopy

    Science.gov (United States)

    Dukic, Maja; Todorov, Vencislav; Andany, Santiago; Nievergelt, Adrian P.; Yang, Chen; Hosseini, Nahid; Fantner, Georg E.

    2017-12-01

    Nearly all scanning probe microscopes (SPMs) contain a feedback controller, which is used to move the scanner in the direction of the z-axis in order to maintain a constant setpoint based on the tip-sample interaction. The most frequently used feedback controller in SPMs is the proportional-integral (PI) controller. The bandwidth of the PI controller presents one of the speed limiting factors in high-speed SPMs, where higher bandwidths enable faster scanning speeds and higher imaging resolution. Most SPM systems use digital signal processor-based PI feedback controllers, which require analog-to-digital and digital-to-analog converters. These converters introduce additional feedback delays which limit the achievable imaging speed and resolution. In this paper, we present a digitally controlled analog proportional-integral-derivative (PID) controller. The controller implementation allows tunability of the PID gains over a large amplification and frequency range, while also providing precise control of the system and reproducibility of the gain parameters. By using the analog PID controller, we were able to perform successful atomic force microscopy imaging of a standard silicon calibration grating at line rates up to several kHz.

  11. PC-based digital feedback control for scanning force microscope

    International Nuclear Information System (INIS)

    Mohd Ashhar Khalid

    2002-01-01

    In the past, most digital feedback implementation for scanned-probe microscope were based on a digital signal processor (DSP). At present DSP plug-in card with the input-output interface module is still expensive compared to a fast pentium PC motherboard. For a magnetic force microscope (MFM) digital feedback has an advantage where the magnetic signal can be easily separated from the topographic signal. In this paper, a simple low-cost PC-based digital feedback and imaging system for Scanning Force Microscope (SFM) is presented. (Author)

  12. Scanning control and data acquisition interface for a spectroscopy diagnostic

    International Nuclear Information System (INIS)

    Lopez-Callejas, R.; Galindo, S.; Benitez-Read, J.S.; Pacheco-Sotelo, J.; Longoria-Gandara, L.C.; Valencia-Alvarado, R.

    2001-01-01

    This work presents the design of a PC supported interface unit that improves the operation of a mechanically driven Czerny-Turner monochromator to the point of meeting the conditions required to be useful in wavelength separation and spectrum analysis for breakdown and conditioning discharges in plasma physics diagnostics. The PC supported interface verifies and sets the position and scan range of the instrument scanning drive. The interface consists of a microcontroller and its associated circuitry. The microcontroller is also used as a data acquisition and data manipulation element. An example of obtained spectra illustrating the instrument greatly improved performance is presented

  13. Automated Quantification of Stroke Damage on Brain Computed Tomography Scans: e-ASPECTS

    Directory of Open Access Journals (Sweden)

    James Hampton-Till

    2015-08-01

    Full Text Available Emergency radiological diagnosis of acute ischaemic stroke requires the accurate detection and appropriate interpretation of relevant imaging findings. Non-contrast computed tomography (CT provides fast and low-cost assessment of the early signs of ischaemia and is the most widely used diagnostic modality for acute stroke. The Alberta Stroke Program Early CT Score (ASPECTS is a quantitative and clinically validated method to measure the extent of ischaemic signs on brain CT scans. The CE-marked electronic-ASPECTS (e-ASPECTS software automates the ASPECTS score. Anglia Ruskin Clinical Trials Unit (ARCTU independently carried out a clinical investigation of the e-ASPECTS software, an automated scoring system which can be integrated into the diagnostic pathway of an acute ischaemic stroke patient, thereby assisting the physician with expert interpretation of the brain CT scan. Here we describe a literature review of the clinical importance of reliable assessment of early ischaemic signs on plain CT scans, and of technologies automating these processed scoring systems in ischaemic stroke on CT scans focusing on the e-ASPECTS software. To be suitable for critical appraisal in this evaluation, the published studies needed a sample size of a minimum of 10 cases. All randomised studies were screened and data deemed relevant to demonstration of performance of ASPECTS were appraised. The literature review focused on three domains: i interpretation of brain CT scans of stroke patients, ii the application of the ASPECTS score in ischaemic stroke, and iii automation of brain CT analysis. Finally, the appraised references are discussed in the context of the clinical impact of e-ASPECTS and the expected performance, which will be independently evaluated by a non-inferiority study conducted by the ARCTU.

  14. Computer-aided detection system for lung cancer in computed tomography scans: Review and future prospects

    Science.gov (United States)

    2014-01-01

    Introduction The goal of this paper is to present a critical review of major Computer-Aided Detection systems (CADe) for lung cancer in order to identify challenges for future research. CADe systems must meet the following requirements: improve the performance of radiologists providing high sensitivity in the diagnosis, a low number of false positives (FP), have high processing speed, present high level of automation, low cost (of implementation, training, support and maintenance), the ability to detect different types and shapes of nodules, and software security assurance. Methods The relevant literature related to “CADe for lung cancer” was obtained from PubMed, IEEEXplore and Science Direct database. Articles published from 2009 to 2013, and some articles previously published, were used. A systemic analysis was made on these articles and the results were summarized. Discussion Based on literature search, it was observed that many if not all systems described in this survey have the potential to be important in clinical practice. However, no significant improvement was observed in sensitivity, number of false positives, level of automation and ability to detect different types and shapes of nodules in the studied period. Challenges were presented for future research. Conclusions Further research is needed to improve existing systems and propose new solutions. For this, we believe that collaborative efforts through the creation of open source software communities are necessary to develop a CADe system with all the requirements mentioned and with a short development cycle. In addition, future CADe systems should improve the level of automation, through integration with picture archiving and communication systems (PACS) and the electronic record of the patient, decrease the number of false positives, measure the evolution of tumors, evaluate the evolution of the oncological treatment, and its possible prognosis. PMID:24713067

  15. Optomechatronics Design and Control for Confocal Laser Scanning Microscopy

    NARCIS (Netherlands)

    Yoo, H.W.

    2015-01-01

    Confocal laser scanning microscopy (CLSM) is considered as one of the major advancements in microscopy in the last century and is widely accepted as a 3D fluorescence imaging tool for biological studies. For the emerging biological questions CLSM requires fast imaging to detect rapid biological

  16. Scanning Emitter Lifetime Imaging Microscopy for Spontaneous Emission Control

    DEFF Research Database (Denmark)

    Frimmer, Martin; Chen, Yuntian; Koenderink, A. Femius

    2011-01-01

    We report an experimental technique to map and exploit the local density of optical states of arbitrary planar nanophotonic structures. The method relies on positioning a spontaneous emitter attached to a scanning probe deterministically and reversibly with respect to its photonic environment while...

  17. Computer vision in control systems

    CERN Document Server

    Jain, Lakhmi

    2015-01-01

    Volume 1 : This book is focused on the recent advances in computer vision methodologies and technical solutions using conventional and intelligent paradigms. The Contributions include: ·         Morphological Image Analysis for Computer Vision Applications. ·         Methods for Detecting of Structural Changes in Computer Vision Systems. ·         Hierarchical Adaptive KL-based Transform: Algorithms and Applications. ·         Automatic Estimation for Parameters of Image Projective Transforms Based on Object-invariant Cores. ·         A Way of Energy Analysis for Image and Video Sequence Processing. ·         Optimal Measurement of Visual Motion Across Spatial and Temporal Scales. ·         Scene Analysis Using Morphological Mathematics and Fuzzy Logic. ·         Digital Video Stabilization in Static and Dynamic Scenes. ·         Implementation of Hadamard Matrices for Image Processing. ·         A Generalized Criterion ...

  18. Computer control for remote wind turbine operation

    Energy Technology Data Exchange (ETDEWEB)

    Manwell, J.F.; Rogers, A.L.; Abdulwahid, U.; Driscoll, J. [Univ. of Massachusetts, Amherst, MA (United States)

    1997-12-31

    Light weight wind turbines located in harsh, remote sites require particularly capable controllers. Based on extensive operation of the original ESI-807 moved to such a location, a much more sophisticated controller than the original one has been developed. This paper describes the design, development and testing of that new controller. The complete control and monitoring system consists of sensor and control inputs, the control computer, control outputs, and additional equipment. The control code was written in Microsoft Visual Basic on a PC type computer. The control code monitors potential faults and allows the turbine to operate in one of eight states: off, start, run, freewheel, low wind shut down, normal wind shutdown, emergency shutdown, and blade parking. The controller also incorporates two {open_quotes}virtual wind turbines,{close_quotes} including a dynamic model of the machine, for code testing. The controller can handle numerous situations for which the original controller was unequipped.

  19. THE USE OF COMPUTER VISION ALGORITHMS FOR AUTOMATIC ORIENTATION OF TERRESTRIAL LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    J. S. Markiewicz

    2016-06-01

    Full Text Available The paper presents analysis of the orientation of terrestrial laser scanning (TLS data. In the proposed data processing methodology, point clouds are considered as panoramic images enriched by the depth map. Computer vision (CV algorithms are used for orientation, which are applied for testing the correctness of the detection of tie points and time of computations, and for assessing difficulties in their implementation. The BRISK, FASRT, MSER, SIFT, SURF, ASIFT and CenSurE algorithms are used to search for key-points. The source data are point clouds acquired using a Z+F 5006h terrestrial laser scanner on the ruins of Iłża Castle, Poland. Algorithms allowing combination of the photogrammetric and CV approaches are also presented.

  20. The Use of Computer Vision Algorithms for Automatic Orientation of Terrestrial Laser Scanning Data

    Science.gov (United States)

    Markiewicz, Jakub Stefan

    2016-06-01

    The paper presents analysis of the orientation of terrestrial laser scanning (TLS) data. In the proposed data processing methodology, point clouds are considered as panoramic images enriched by the depth map. Computer vision (CV) algorithms are used for orientation, which are applied for testing the correctness of the detection of tie points and time of computations, and for assessing difficulties in their implementation. The BRISK, FASRT, MSER, SIFT, SURF, ASIFT and CenSurE algorithms are used to search for key-points. The source data are point clouds acquired using a Z+F 5006h terrestrial laser scanner on the ruins of Iłża Castle, Poland. Algorithms allowing combination of the photogrammetric and CV approaches are also presented.

  1. Disk access controller for Multi 8 computer

    International Nuclear Information System (INIS)

    Segalard, Jean

    1970-01-01

    After having presented the initial characteristics and weaknesses of the software provided for the control of a memory disk coupled with a Multi 8 computer, the author reports the development and improvement of this controller software. He presents the different constitutive parts of the computer and the operation of the disk coupling and of the direct access to memory. He reports the development of the disk access controller: software organisation, loader, subprograms and statements

  2. Abdominal computed tomography scan as a screening tool in blunt trauma

    International Nuclear Information System (INIS)

    Brasel, K.J.; Borgstrom, D.C.; Kolewe, K.A.

    1997-01-01

    Background. One of the most difficult problems in blunt trauma is evaluation for potential intraabdominal injury. Admission for serial abdominal exams remains the standard of care after intraabdominal injury has been initially excluded. We hypothesized a normal abdominal computed tomography (CT) scan in a subgroup of minimally injured patients would obviate admission for serial abdominal examinations, allowing safe discharge from the emergency department (ED). Methods. We reviewed our blunt trauma experience with patients admitted solely for serial abdominal examinations after a normal CT. Patients were identified from the trauma registry at a Level 1 trauma center from July 1991 through June 1995. Patients with abnormal CTs, extra-abdominal injuries necessitating admission, hemodynamic abnormalities, a Glasgow Coma Scale less than 13, or injury severity scores (ISSs) greater than 15 were excluded. Records of 238 patients remained; we reviewed them to determine the presence of missed abdominal injury. Results. None of the 238 patients had a missed abdominal injury. Average ISS of these patients was 3.2 (range, 0 to 10). Discharging these patients from the ED would result in a yearly cost savings of $32,874 to our medical system. Conclusions. Abdominal CT scan is a safe and cost-effective screening tool in patients with blunt trauma. A normal CT scan in minimally injured patients allows safe discharge from the ED. (authors)

  3. Does high-power computed tomography scanning equipment affect the operation of pacemakers?

    International Nuclear Information System (INIS)

    Yamaji, Satoshi; Imai, Shinobu; Saito, Fumio; Yagi, Hiroshi; Kushiro, Toshio; Uchiyama, Takahisa

    2006-01-01

    Computed tomography (CT) is widely used in clinical practice, but there has not been a detailed report of its effect on the functioning of pacemakers. During CT, ECGs were recorded in 11 patients with pacemakers and the electromagnetic field in the CT room was also measured. The effect of CT on a pacemaker was also investigated in a human body model with and without shielding by rubber or lead. Transient malfunctions of pacemakers during CT occurred in 6 of 11 patients. The model showed that malfunctioning of the pacemaker was induced by CT scanning and this was prevented by lead but not by rubber. The alternating electrical field was 150 V/m on the CT scanning line, which was lower than the level influencing pacemaker functions. The alternating magnetic field was 15μT on the CT scanning line, which was also lower than the level influencing pacemaker functions. Malfunctions of the pacemaker during CT may be caused by diagnostic radiant rays and although they are transient, the possibility of lethal arrhythmia cannot be ignored. (author)

  4. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    Energy Technology Data Exchange (ETDEWEB)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A. [The University of Iowa, Department of Biomedical Engineering, Center for Computer Aided Design, Iowa City, IA (United States); Shivanna, Kiran H. [The University of Iowa, Center for Computer Aided Design, Iowa City, IA (United States); Magnotta, Vincent A. [The University of Iowa, Department of Biomedical Engineering, Department of Radiology, Center for Computer Aided Design, Iowa City, IA (United States); Grosland, Nicole M. [The University of Iowa, Department of Biomedical Engineering, Department of Orthopaedics and Rehabilitation, Center for Computer Aided Design, Iowa City, IA (United States)

    2008-01-15

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  5. X-rays computed tomographic scans of lower limb and trunk muscles in facioscapulohumeral muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Horikawa, Hirosei; Mano, Yukio; Takayanagi, Tetsuya [Nara Medical Univ., Kashihara (Japan); Takahashi, Keiichi; Nishio, Hisahide

    1992-10-01

    X-rays computed tomographic (CT) scans of muscles of the lower limbs and the trunk in 14 patients with facioscapulohumeral muscular dystrophy (FSH) were studied. The CT scans showed that the affected muscles were decreased in density and size. The laterality of muscular involvement was sometimes observed. The muscular lesions in the lower limbs showed proximal distribution. In the thigh, the hamstrings were affected first, the adductor muscles second, and then the muscular involvement progressed to the quadriceps femoris muscle. In the lower leg, the gastrocnemius and soleus muscles were relatively spared as compared with the tibialis anterior muscle. In the lumbar girdle, the abdominal muscles were involved first, the gluteal muscles second, the back muscles third, and the psoas major muscle were relatively spared. The muscular weakness of this distribution exacerbated lumbar lordosis. The neck muscles were less affected than those of the lumbar girdle. The CT scans in FSH demonstrated the characteristic pattern of muscular involvement, which differed from the inherited muscular diseases such as Duchenne muscular dystrophy, myotonic dystrophy, and others. (author).

  6. X-rays computed tomographic scans of lower limb and trunk muscles in facioscapulohumeral muscular dystrophy

    International Nuclear Information System (INIS)

    Horikawa, Hirosei; Mano, Yukio; Takayanagi, Tetsuya; Takahashi, Keiichi; Nishio, Hisahide.

    1992-01-01

    X-rays computed tomographic (CT) scans of muscles of the lower limbs and the trunk in 14 patients with facioscapulohumeral muscular dystrophy (FSH) were studied. The CT scans showed that the affected muscles were decreased in density and size. The laterality of muscular involvement was sometimes observed. The muscular lesions in the lower limbs showed proximal distribution. In the thigh, the hamstrings were affected first, the adductor muscles second, and then the muscular involvement progressed to the quadriceps femoris muscle. In the lower leg, the gastrocnemius and soleus muscles were relatively spared as compared with the tibialis anterior muscle. In the lumbar girdle, the abdominal muscles were involved first, the gluteal muscles second, the back muscles third, and the psoas major muscle were relatively spared. The muscular weakness of this distribution exacerbated lumbar lordosis. The neck muscles were less affected than those of the lumbar girdle. The CT scans in FSH demonstrated the characteristic pattern of muscular involvement, which differed from the inherited muscular diseases such as Duchenne muscular dystrophy, myotonic dystrophy, and others. (author)

  7. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    International Nuclear Information System (INIS)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A.; Shivanna, Kiran H.; Magnotta, Vincent A.; Grosland, Nicole M.

    2008-01-01

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  8. Body composition measurement using computed tomography: Does the phase of the scan matter?

    Science.gov (United States)

    Rollins, Katie E; Javanmard-Emamghissi, Hannah; Awwad, Amir; Macdonald, Ian A; Fearon, Kenneth C H; Lobo, Dileep N

    2017-09-01

    The aim of this study was to determine, from the methodologic standpoint, the effect of the presence or absence of intravenous contrast on body composition variables obtained by analysis of computed tomography (CT) images. Triphasic abdominal (noncontrast, arterial phase, and portovenous phase contrast) CT scans from 111 patients were analyzed by two independent assessors at the third lumbar vertebral level using SliceOmatic software (version 5.0, TomoVision, Montreal, Canada). Variables included skeletal muscle index (SMI), fat and fat-free mass (FM and FFM, respectively), and mean skeletal muscle Hounsfield units (SMHU). Mean SMHU was lowest in the noncontrast phase (29.4, standard deviation [SD] 8.9 HU), followed by arterial (32.4, SD 9.3 HU) then portovenous phases (34.9, SD 9.4 HU). The mean skeletal muscle attenuation was significantly different depending on the phase of the scan in which the images were obtained. Calculated FM was significantly lower in both arterial (28.6, SD 8.8 kg, P definition of myosteatosis should include a standardized phase of CT for analysis and this should be incorporated within its definition. However, as the magnitudes of the differences were relatively small, the effect of the phase of the scan on predicting outcome needs to be determined. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Guided access cavity preparation using cone-beam computed tomography and optical surface scans - an ex vivo study

    DEFF Research Database (Denmark)

    Buchgreitz, J; Buchgreitz, M; Mortensen, D

    2016-01-01

    AIM: To evaluate ex vivo, the accuracy of a preparation procedure planned for teeth with pulp canal obliteration (PCO) using a guide rail concept based on a cone-beam computed tomography (CBCT) scan merged with an optical surface scan. METHODOLOGY: A total of 48 teeth were mounted in acrylic bloc...

  10. Frequent Computed Tomography Scanning Due to Incomplete Three-View X-Ray Imaging of the Cervical Spine

    NARCIS (Netherlands)

    Saltzherr, Teun Peter; Beenen, Ludo F. M.; Reitsma, Johannes B.; Luitse, Jan S. K.; Vandertop, W. Peter; Goslings, J. Carel

    2010-01-01

    Background: Conventional C-spine imaging (3-view series) is still widely used in trauma patients, although the utilization of computed tomography (CT) scanning is increasing. The aim of this study was to analyze the value of conventional radiography and the frequency of subsequent CT scanning due to

  11. Soft computing in intelligent control

    CERN Document Server

    Jung, Jin-Woo; Kubota, Naoyuki

    2014-01-01

    Nowadays, people have tendency to be fond of smarter machines that are able to collect data, make learning, recognize things, infer meanings, communicate with human and perform behaviors. Thus, we have built advanced intelligent control affecting all around societies; automotive, rail, aerospace, defense, energy, healthcare, telecoms and consumer electronics, finance, urbanization. Consequently, users and consumers can take new experiences through the intelligent control systems. We can reshape the technology world and provide new opportunities for industry and business, by offering cost-effective, sustainable and innovative business models. We will have to know how to create our own digital life. The intelligent control systems enable people to make complex applications, to implement system integration and to meet society’s demand for safety and security. This book aims at presenting the research results and solutions of applications in relevance with intelligent control systems. We propose to researchers ...

  12. Computationally efficient methods for digital control

    NARCIS (Netherlands)

    Guerreiro Tome Antunes, D.J.; Hespanha, J.P.; Silvestre, C.J.; Kataria, N.; Brewer, F.

    2008-01-01

    The problem of designing a digital controller is considered with the novelty of explicitly taking into account the computation cost of the controller implementation. A class of controller emulation methods inspired by numerical analysis is proposed. Through various examples it is shown that these

  13. A computable type theory for control systems

    NARCIS (Netherlands)

    P.J. Collins (Pieter); L. Guo; J. Baillieul

    2009-01-01

    htmlabstractIn this paper, we develop a theory of computable types suitable for the study of control systems. The theory uses type-two effectivity as the underlying computational model, but we quickly develop a type system which can be manipulated abstractly, but for which all allowable operations

  14. Computer-controlled gamma-ray scanner for irradiated reactor fuel

    International Nuclear Information System (INIS)

    Mandler, J.W.; Coates, R.A.; Killian, E.W.

    1979-01-01

    Gamma-ray scanning of irradiated fuel is an important nondestructive technique used in the thermal fuels behavior program currently under way at the Idaho National Engineering Laboratory. This paper is concerned with the computer-controlled isotopic gamma-ray-scanning system developed for postirradiation examination of fuel and includes a brief discussion of some scan results obtained from fuel rods irradiated in the Power-Burst Facility to illustrate gamma-ray spectrometry for this application. Both burnup profiles and information concerning fission-product migration in irradiated fuel are routinely obtained with the computer-controlled system

  15. Controlling Laboratory Processes From A Personal Computer

    Science.gov (United States)

    Will, H.; Mackin, M. A.

    1991-01-01

    Computer program provides natural-language process control from IBM PC or compatible computer. Sets up process-control system that either runs without operator or run by workers who have limited programming skills. Includes three smaller programs. Two of them, written in FORTRAN 77, record data and control research processes. Third program, written in Pascal, generates FORTRAN subroutines used by other two programs to identify user commands with device-driving routines written by user. Also includes set of input data allowing user to define user commands to be executed by computer. Requires personal computer operating under MS-DOS with suitable hardware interfaces to all controlled devices. Also requires FORTRAN 77 compiler and device drivers written by user.

  16. Focus scanning with feedback control for fiber-optic nonlinear endomicroscopy (Conference Presentation)

    Science.gov (United States)

    Li, Ang; Liang, Wenxuan; Li, Xingde

    2017-02-01

    Fiber-optic nonlinear endomicroscopy represents a strong promise to enable translation of nonlinear microscopy technologies to in vivo applications, particularly imaging of internal organs. Two-dimensional imaging beam scanning has been accomplished by using fiber-optic scanners or MEMS scanners. Yet nonlinear endomicroscopy still cannot perform rapid and reliable depth or focus scanning while maintaining a small form factor. Shape memory alloy (SMA) wire had shown promise in extending 2D endoscopic imaging to the third dimension. By Joule heating, the SMA wire would contract and move the endomicroscope optics to change beam focus. However, this method suffered from hysteresis, and was susceptible to change in ambient temperature, making it difficult to achieve accurate and reliable depth scanning. Here we present a feedback-controlled SMA actuator which addressed these challenges. The core of the feedback loop was a Hall effect sensor. By measuring the magnetic flux density from a tiny magnet attached to the SMA wire, contraction distance of the SMA wire could be tracked in real time. The distance was then fed to the PID algorithm running in a microprocessor, which computed the error between the command position and the current position of the actuator. The current running through the SMA wire was adjusted accordingly. Our feedback-controlled SMA actuator had a tube-like shape with outer diameter of 5.5 mm and length of 25 mm, and was designed to house the endomicroscope inside. Initial test showed that it allowed more than 300 microns of travel distance, with an average positioning error of less than 2 microns. 3D imaging experiments with the endomicroscope is underway, and its imaging performance will be assessed and discussed.

  17. A computationally efficient fuzzy control s

    Directory of Open Access Journals (Sweden)

    Abdel Badie Sharkawy

    2013-12-01

    Full Text Available This paper develops a decentralized fuzzy control scheme for MIMO nonlinear second order systems with application to robot manipulators via a combination of genetic algorithms (GAs and fuzzy systems. The controller for each degree of freedom (DOF consists of a feedforward fuzzy torque computing system and a feedback fuzzy PD system. The feedforward fuzzy system is trained and optimized off-line using GAs, whereas not only the parameters but also the structure of the fuzzy system is optimized. The feedback fuzzy PD system, on the other hand, is used to keep the closed-loop stable. The rule base consists of only four rules per each DOF. Furthermore, the fuzzy feedback system is decentralized and simplified leading to a computationally efficient control scheme. The proposed control scheme has the following advantages: (1 it needs no exact dynamics of the system and the computation is time-saving because of the simple structure of the fuzzy systems and (2 the controller is robust against various parameters and payload uncertainties. The computational complexity of the proposed control scheme has been analyzed and compared with previous works. Computer simulations show that this controller is effective in achieving the control goals.

  18. NQR spectrometer controlled by a computer

    International Nuclear Information System (INIS)

    Stoican, Ovidiu

    2002-01-01

    Nuclear quadrupole resonance (NQR) is one of the sensitive methods for studying physical and chemical properties of a substance, such as chemical composition, molecular structure, molecular motion and electronic environment. The specifications of the research project require the use of a nuclear quadrupole resonance spectrometer. Design and performances of a pulsed nuclear quadrupole resonance spectrometer prototype covering the range 1-10 MHz are presented. The pulsed NQR method offers considerably higher sensitivity than either the marginal oscillator or super-regenerative methods. Strong echoes are often observed directly with an oscilloscope or a simple receiver. The method allows us to observe two signal categories: free induction decay (fid) and echoes. The block diagram of the pulsed nuclear quadrupole resonance spectrometer is shown. All operations performed by the spectrometer are controlled by a computer. The scanning frequency range, amplitude and width of the RF pulse, additional magnetic field and sample temperature can be controlled by the software. Also it is possible to improve the signal-to-noise ratio using digital filtering applied to the data stored. Automatic operation eliminates operator skill and uncertainty of manual operation. The NQR spectrometer control software is a stand alone executable file, runs on Windows 95/98 platform and does not require the existence of another software package. A graphical interface allows to user an easy control over the spectrometer operations. All measured parameters by the control system interface are saved in the standard data files and can be processed further. The design is readily adaptable for other applications. The sample is contained within an aluminum cylindrical case. The upper end cap of the case can be removed and it allows introducing the sample. On the upper end cap RF and main temperature sensor connector are placed. On the internal side of the bottom end cap a thermoelectric cooler (MELCOR

  19. Computer controlled quality of analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  20. The Prevalence of Unanticipated Hamate Hook Abnormalities in Computed Tomography Scans: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Silke A. Spit

    2017-05-01

    Full Text Available Background:It is possible that some hamate hook fractures are not diagnosed or treated, thereby affecting the study of their natural history. Study of the prevalence of incidental hamate hook fractures, nonunions, and other abnormalities on computed tomography (CT ordered for another reason could document a subset of undiagnosed and untreated hamate hook fractures which might change our understanding about the natural history.Methods: Reports of 2489 hand, wrist, and forearm CT scans for hamate hook abnormalities were searched. We excluded 19 patients with anticipated hamate fractures and 1 patient that had a hamate hook excision. Twenty-eight patients had an unanticipated hamate hook abnormality.Results: There was a significant difference in the prevalence of incidental hamate hook abnormalities by sex but not by age. Among the 28 unexpected hamate hook abnormalities, there were 16 fractures of the base (12 acute, 1 nonunion, and 3 of uncertain age, 5 acute oblique fractures, and 7 tip abnormalities/ossicles. The patient with an incidental nonunion had a CT scan for wrist pain and was diagnosed with gout.All fractures involved a direct blow to the hand (distal radius or scaphoid fracture, or crush injury. The 7 patients with a hamate tip abnormality had a CT scan for a distal radius or metacarpal fracture, crush injury or wrist pain. Five acute fractures were treated operatively with excision and the other 23 fractures were treated nonoperatively.Conclusion: Hamate fractures can be diagnosed incidental to other hand and wrist problems on CT.

  1. Clinical observations of the brain abscesses, especially on the computed tomographic brain scan findings

    International Nuclear Information System (INIS)

    Kitano, Masahiko; Kuroda, Ryotaro; Yamada, Yasufumi; Yorimae, Akira; Akai, Fumiharu; Watanabe, Masaru; Nakatani, Jiro; Ioku, Masahiko

    1988-01-01

    Fifteen cases with pyogenic brain abscess were experienced in our clinic during the last 7 years. The records of these patients were examined to evaluate the clinical stage and the result of several treatments. In 12 operative cases, diagnosis was made by fluid aspirated from the abscess. Bacteria were cultured from the fluid in 5 among these cases. In 3 other non-operative patients, diagnosis was based on computed tomographic (CT) brain scans and laboratory studies. Each volume of the brain abscess and surrounding brain edema was measured on serial CT scans to evaluate the clinical stage and the abscess evolution. In symptoms and signs, it has been thought that one of the factors contributing to mortality was the level of consciousness. In this study, the disturbance of consciousness did not correlate with the size of abscess, but with that of edema. The cases reported here were divided into 3 groups according to the volume of abscess and of edema on initial CT scans. The cases of group A had small surrounding edema ( 50 ml) and small abscess ( 25 ml). The group A had slight change in the clinical status and the size of edema, but the others had severe change. Three phase changes in edema size were seen in the group B regardless of therapeutic modalities ; showing almost constant increase in first 2 weeks, great decrease in second 2 weeks and moderate decrease following these 4 weeks. In the group C, however, these phases were seen only in early operation cases. (J.P.N.)

  2. Role of computed tomography (CT scan in staging of cervical carcinoma

    Directory of Open Access Journals (Sweden)

    T V Prasad

    2014-01-01

    Full Text Available Background & objectives: Staging of cervical carcinoma is done clinically using International Federation of Obstetrics and Gynecology (FIGO guidelines. It is based on physical examination findings and also includes results of biopsy, endoscopy and conventional radiological tests like chest radiograph, intravenous urography and barium enema. These conventional radiological investigations have largely been replaced by computed tomography (CT and magnetic resonance imaging (MRI at present. FIGO staging system does not consider CT and MRI mandatory; however, use of these modalities are encouraged. This prospective study was conducted to determine the role of CT in staging work up in women diagnosed with cervical carcinoma. Methods: Fifty three women diagnosed with cervical carcinoma were evaluated with contrast enhanced CT scan of abdomen and pelvis. CT scan images were especially evaluated to determine tumour size, invasion of parmetrium, pelvic walls, rectum, urinary bladder and ureters, pelvic or retroperitoneal lymphadenopathy and distant metastases. CT findings were associated with clinical findings and staging, including findings from cystoscopy and sigmoidoscopy. Results: There was a poor agreement between clinical and CT staging of cervical carcinoma. Primary tumour was demonstrated on CT in 36 (70% of 53 patients. CT underestimated the parametrial, vaginal and pelvic wall invasion when compared with physical examination. CT overestimated the urinary bladder and rectal invasion when compared with cysto-sigmoidoscopy, however, CT had 100 per cent negative predictive value (NPV to exclude bladder and rectal involvement. CT detection of lymph node enlargement and lung metastases influenced the management. Interpretation & conclusions: Our findings show that CT scan does not reliably correlate with clinical FIGO staging of cervical cancer. However, it can detect urinary obstruction as well as nodal or distant metastases and thus improves the

  3. Birt-Hogg-Dube syndrome prospectively detected by review of chest computed tomography scans.

    Directory of Open Access Journals (Sweden)

    Hye Jung Park

    Full Text Available Birt-Hogg-Dube syndrome (BHD is a rare disorder caused by mutations in the gene that encodes folliculin (FLCN and is inherited in an autosomal dominant manner. BHD is commonly accompanied by fibrofolliculomas, renal tumors, multiple pulmonary cysts, and spontaneous pneumothorax. The aim of this study was to detect BHD prospectively in patients undergoing chest computed tomography (CT scans and to evaluate further the characteristics of BHD in Korea.We prospectively checked and reviewed the chest CT scans obtained for 10,883 patients at Gangnam Severance Hospital, Seoul, Korea, from June 1, 2015 to May 31, 2016. Seventeen patients met the study inclusion criteria and underwent screening for FLCN mutation to confirm BHD. We analyzed the characteristics of the patients confirmed to have BHD and those for a further 6 patients who had previously been described in Korea.Six (0.06% of the 10,883 patients reviewed were diagnosed with BHD. There was no difference in demographic or clinical features between the patients with BHD (n = 6 and those without BHD (n = 11. Pneumothorax was present in 50% of the patients with BHD but typical skin and renal lesions were absent. The maximum size of the cysts in the BHD group (median 39.4 mm; interquartile range [IQR] 11.4 mm was significantly larger than that in the non-BHD group (median 15.8 mm; IQR 7.8 mm; P = 0.001. Variable morphology was seen in 100.0% of the cysts in the BHD group but in only 18.2% of the cysts in the non-BHD group (P = 0.002. Nine (95% of the total of 12 Korean patients with BHD had experienced pneumothorax. Typical skin and renal lesions were present in 20.0% of patients with BHD.Our findings suggest that BHD can be detected if chest CT scans are read in detail.

  4. Endoscopic ultrasonography and computed tomography scanning for preoperative staging of colonic cancer

    DEFF Research Database (Denmark)

    Malmstrøm, M L; Gögenur, I; Riis, L B

    2017-01-01

    PURPOSE: With an increasing demand for more accurate preoperative staging methods for colon cancer, we aimed to compare preoperative tumour (T)- and nodal (N)-stage in patients with left-sided colon cancer by endoscopic ultrasonography (EUS) and computed tomography (CT) with post......-operative histology as gold standard. METHODS: A total of 44 patients were prospectively recruited at Herlev and Roskilde University Hospitals during November 2014-January 2016. Thirty-five patients were included in the final analysis and underwent EUS, CT and surgery within 2 weeks. Diagnostic values were evaluated...... difficult to evaluate due to small patient numbers. EUS could be considered as a supplement to CT scans in selecting patients for neoadjuvant therapies, or local transmural treatment, in the future. TRIAL REGISTRATION: NCT02324023....

  5. Collateral findings during computed tomography scan for atrial fibrillation ablation: Let's take a look around.

    Science.gov (United States)

    Perna, Francesco; Casella, Michela; Narducci, Maria Lucia; Dello Russo, Antonio; Bencardino, Gianluigi; Pontone, Gianluca; Pelargonio, Gemma; Andreini, Daniele; Vitulano, Nicola; Pizzamiglio, Francesca; Conte, Edoardo; Crea, Filippo; Tondo, Claudio

    2016-04-26

    The growing number of atrial fibrillation catheter ablation procedures warranted the development of advanced cardiac mapping techniques, such as image integration between electroanatomical map and cardiac computed tomography. While scanning the chest before catheter ablation, it is frequent to detect cardiac and extracardiac collateral findings. Most collateral findings are promptly recognized as benign and do not require further attention. However, sometimes clinically relevant collateral findings are detected, which often warrant extra diagnostic examinations or even invasive procedure, and sometimes need to be followed-up over time. Even though reporting and further investigating collateral findings has not shown a clear survival benefit, almost all the working groups providing data on collateral findings reported some collateral findings eventually coming out to be malignancies, sometimes at an early stage. Therefore, there is currently no clear agreement about the right strategy to be followed.

  6. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  7. Prediction of intramuscular fat levels in Texel lamb loins using X-ray computed tomography scanning.

    Science.gov (United States)

    Clelland, N; Bunger, L; McLean, K A; Conington, J; Maltin, C; Knott, S; Lambe, N R

    2014-10-01

    For the consumer, tenderness, juiciness and flavour are often described as the most important factors for meat eating quality, all of which have a close association with intramuscular fat (IMF). X-ray computed tomography (CT) can measure fat, muscle and bone volumes and weights, in vivo in sheep and CT predictions of carcass composition have been used in UK sheep breeding programmes over the last few decades. This study aimed to determine the most accurate combination of CT variables to predict IMF percentage of M. longissimus lumborum in Texel lambs. As expected, predicted carcass fat alone accounted for a moderate amount of the variation (R(2)=0.51) in IMF. Prediction accuracies were significantly improved (Adj R(2)>0.65) using information on fat and muscle densities measured from three CT reference scans, showing that CT can provide an accurate prediction of IMF in the loin of purebred Texel sheep. Copyright © 2014. Published by Elsevier Ltd.

  8. Image interpolation allows accurate quantitative bone morphometry in registered micro-computed tomography scans.

    Science.gov (United States)

    Schulte, Friederike A; Lambers, Floor M; Mueller, Thomas L; Stauber, Martin; Müller, Ralph

    2014-04-01

    Time-lapsed in vivo micro-computed tomography is a powerful tool to analyse longitudinal changes in the bone micro-architecture. Registration can overcome problems associated with spatial misalignment between scans; however, it requires image interpolation which might affect the outcome of a subsequent bone morphometric analysis. The impact of the interpolation error itself, though, has not been quantified to date. Therefore, the purpose of this ex vivo study was to elaborate the effect of different interpolator schemes [nearest neighbour, tri-linear and B-spline (BSP)] on bone morphometric indices. None of the interpolator schemes led to significant differences between interpolated and non-interpolated images, with the lowest interpolation error found for BSPs (1.4%). Furthermore, depending on the interpolator, the processing order of registration, Gaussian filtration and binarisation played a role. Independent from the interpolator, the present findings suggest that the evaluation of bone morphometry should be done with images registered using greyscale information.

  9. Computation Reduction Oriented Circular Scanning SAR Raw Data Simulation on Multi-GPUs

    Directory of Open Access Journals (Sweden)

    Hu Chen

    2016-08-01

    Full Text Available As a special working mode, the circular scanning Synthetic Aperture Radar (SAR is widely used in the earth observation. With the increase of resolution and swath width, the simulation data has a massive increase, which boosts the new requirements of efficiency. Through analyzing the redundancy in the raw data simulation based on Graphics Processing Unit (GPU, a fast simulation method considering reduction of redundant computation is realized by the multi-GPUs and Message Passing Interface (MPI. The results show that the efficiency of 4-GPUs increases 2 times through the redundant reduction, and the hardware cost decreases by 50%, thus the overall speedup achieves 350 times than the traditional CPU simulation.

  10. Internal structure of a vermicular ironstone as determined by X-ray computed tomography scanning

    Energy Technology Data Exchange (ETDEWEB)

    Zinn, Yuri Lopes, E-mail: ylzinn@dcs.ufla.br [Universidade Federal de Lavras (UFLA), Lavras, MG (Brazil). Departamento de Ciencia do Solo; Carducci, Carla Eloize [Universidade Federal de Santa Catarina (UFSC), Curitibanos, SC (Brazil). Departamento de Agronomia; Araujo, Marla Alessandra [Universidade Federal de Lavras (UFLA), Lavras, MG (Brazil). Programa de Pos-graduacao em Ciencia do Solo

    2015-03-15

    Ironstones or petroplinthites are common materials in soils under humid tropical climate, generally defined as the result of Fe oxide accumulation in areas where the water table oscillates, and may exhibit considerable morphological variability. The aim of this study was to examine the internal structure and porosity of an ironstone fragment from a Petroferric Acrudox in Minas Gerais, Brazil, by computed tomography (CT) and conventional techniques. The sample analyzed had total porosity of 59.5 %, with large macropores in the form of tubular channels and irregular vughs, the latter with variable degrees of infilling by material released from the ironstone walls or the soil matrix. The CT scan also showed that the ironstone has wide variation in the density of the solid phase, most likely due to higher concentrations or thick intergrowths of hematite and magnetite/maghemite, especially in its outer rims. The implications of these results for water retention and soil formation in ironstone environments are briefly discussed. (author)

  11. A postmortem correlation of computer tomography and ultrasound scans of periventricular hemorrhage in preterm infants

    International Nuclear Information System (INIS)

    Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Yushiro; Nishimi, Toshihiro; Utsunomiya, Hidetsuna; Nakamura, Yasuhiro; Okudera, Toshio

    1988-01-01

    From January 1984 through September 1987, ultrasound scanning (US), computed tomography (CT), and autopy have been performed in 80 consecutive premature infants. Intracranial lesions consisted of intraventricular hemorrhage (IVH, n = 61), subarachnoid hemorrhage (SAH, n = 63), cerebellar hemorrhage (n = 5), hydrocephalus (n = 8), periventricular leukoencephalomalacia (n = 20), and anoxic encephalopathy (n = 40). Using autopsy findings as the standard, both US and CT had an accuracy of 80 % or more in detecting subependymal hemorrhage (SEH), IVH, dilated ventricle, and parenchymal hemorrhage ; however, both imaging modalities showed a high false negative for SAH (77 % for US vs 55 % for CT). Accuracy of US and CT was 82 % vs 72 % for SEH, and 72 % vs 85 % for IVH. High false positive and false negative rates, in spite of 80 % or more accuracy of imaging modalities, warrant further studies to obtain higher accuracy in the diagnosis of intracranial lesions. (Namekawa, K.)

  12. Postmortem correlation of computer tomography and ultrasound scans of periventricular hemorrhage in preterm infants

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Yushiro; Nishimi, Toshihiro; Utsunomiya, Hidetsuna; Nakamura, Yasuhiro; Okudera, Toshio

    1988-08-01

    From January 1984 through September 1987, ultrasound scanning (US), computed tomography (CT), and autopy have been performed in 80 consecutive premature infants. Intracranial lesions consisted of intraventricular hemorrhage (IVH, n = 61), subarachnoid hemorrhage (SAH, n = 63), cerebellar hemorrhage (n = 5), hydrocephalus (n = 8), periventricular leukoencephalomalacia (n = 20), and anoxic encephalopathy (n = 40). Using autopsy findings as the standard, both US and CT had an accuracy of 80 % or more in detecting subependymal hemorrhage (SEH), IVH, dilated ventricle, and parenchymal hemorrhage ; however, both imaging modalities showed a high false negative for SAH (77 % for US vs 55 % for CT). Accuracy of US and CT was 82 % vs 72 % for SEH, and 72 % vs 85 % for IVH. High false positive and false negative rates, in spite of 80 % or more accuracy of imaging modalities, warrant further studies to obtain higher accuracy in the diagnosis of intracranial lesions. (Namekawa, K.).

  13. Examination of Scanning Electron Microscope and Computed Tomography Images of PICA

    Science.gov (United States)

    Lawson, John W.; Stackpoole, Margaret M.; Shklover, Valery

    2010-01-01

    Micrographs of PICA (Phenolic Impregnated Carbon Ablator) taken using a Scanning Electron Microscope (SEM) and 3D images taken with a Computed Tomography (CT) system are examined. PICA is a carbon fiber based composite (Fiberform ) with a phenolic polymer matrix. The micrographs are taken at different surface depths and at different magnifications in a sample after arc jet testing and show different levels of oxidative removal of the charred matrix (Figs 1 though 13). CT scans, courtesy of Xradia, Inc. of Concord CA, were captured for samples of virgin PICA, charred PICA and raw Fiberform (Fig. 14). We use these images to calculate the thermal conductivity (TC) of these materials using correlation function (CF) methods. CF methods give a mathematical description of how one material is embedded in another and is thus ideally suited for modeling composites like PICA. We will evaluate how the TC of the materials changes as a function of surface depth. This work is in collaboration with ETH-Zurich, which has expertise in high temperature materials and TC modeling (including CF methods).

  14. Relative value of computed tomography scanning and venous sampling in establishing the cause of primary hyperaldosteronism

    International Nuclear Information System (INIS)

    Sheaves, R.; Goldin, J.; Reznek, R.H.

    1996-01-01

    The purpose of this study was to evaluate the relative merits of the postural simulation test, adrenal computed tomography (CT) and venous sampling in the differential diagnosis of patients presenting with primary hyperaldosteronism. The records of 20 patients presenting with primary hyperaldosteronism were reviewed retrospectively. There were 15 patients with a unilateral aldosterone-producing adenoma (APA), 4 patients with idiopathic hyperaldosteronism (IHA) and 1 patient with primary adrenal hyperplasia (PAH). Bilateral venous sampling of adrenal veins was attempted in all patients and blood collected for aldosterone and cortisol assay. Plasma aldosterone concentration increased after 4 h of standing in all cases of hyperplasia, but was also demonstrated in 10/15 patients with a surgically-proven APA. CT scanning correctly identified all 15 cases of APA and also classified correctly the remaining 5 cases of hyperplasia. CT scanning may be used alone to confirm the cause of hyperaldosteronism where postural studies suggest an adrenal adenoma, and such patients may be considered for early surgery. 21 refs

  15. Design and application of Mark IV scanning system for radionuclide computed tomography of the brain

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Hoffman, E.J.; Phelps, M.E.; Ricci, A.; Reivich, M.

    1977-01-01

    The MARK IV system was built in our laboratory to provide fast and accurate radionuclide computed tomography (RCT). It is designed primarily for detecting commonly available radioactive labels such as 99 Tcsup(m), but it is also adapted to detecting positron emitters such as 18 F. The system has interlaced convergent collimation in a four-sided arrangement of 32 independent detectors which continuously rotate as a unit, detecting, processing and displaying the reconstructed data while the study progresses. During the scanning procedure, accumulated data are transferred to a digital computer for reconstruction processing. Data are corrected to equalize detector response and compensate for photon attenuation in the head. This program requires 30 seconds for completion, whereupon the final reconstruction, a 64 x 64 matrix from the single revolution, outputs to a core store and is displayed on the screen of a cathode-ray tube. As the rotation sequence continues, new data from each revolution are added to previous data and reprocessed for a new picture. Since the instrument operates at 50 s per revolution, the continuous collection and processing of data causes a new picture to appear on the display every 50 s as the study progresses. The operator may extend or curtail the duration of the examination according to the appearance of the picture. In practice, a five revolution (4.2 min.) scan is commonly used in most clinical studies. The instrument is a high sensitivity device with approximately uniform resolution (1.7 cm FWHM) throughout the section plane. Quantification of concentration of radioactivity in small regions is accurate and reproducible. The instrument has been applied to the study of alterations in cerebral vascular permeability, blood flow and blood volume, and to the study of cerebral glucose metabolism and cerebral spinal fluid distribution. (author)

  16. Run-to-Run Optimization Control Within Exact Inverse Framework for Scan Tracking.

    Science.gov (United States)

    Yeoh, Ivan L; Reinhall, Per G; Berg, Martin C; Chizeck, Howard J; Seibel, Eric J

    2017-09-01

    A run-to-run optimization controller uses a reduced set of measurement parameters, in comparison to more general feedback controllers, to converge to the best control point for a repetitive process. A new run-to-run optimization controller is presented for the scanning fiber device used for image acquisition and display. This controller utilizes very sparse measurements to estimate a system energy measure and updates the input parameterizations iteratively within a feedforward with exact-inversion framework. Analysis, simulation, and experimental investigations on the scanning fiber device demonstrate improved scan accuracy over previous methods and automatic controller adaptation to changing operating temperature. A specific application example and quantitative error analyses are provided of a scanning fiber endoscope that maintains high image quality continuously across a 20 °C temperature rise without interruption of the 56 Hz video.

  17. Program for large scanning-measuring table calibration on-line with the TRA-1001 computer

    International Nuclear Information System (INIS)

    Kalmykova, L.P.; Ososkov, G.A.; Pogodina, G.A.; Skryl', I.I.

    1975-01-01

    A description of a programme variant for complex calibration of the system of boards BPS-2, is given in which the stage of measurements and accumulation of calibration data is separated from that of data processing on CDC-1604A computers. Stage-by-stage calibration allows for simultaneous and parallel measurements on all the 6 boards. Such a possibility of the boards' operation on a computer-controlled line has been used as checking of the operators' actions with current control of the data obtained. Mathematical formulae are followed by programmes' descriptions. Reception and accumulation of coordinates of the units of the calibrating plate, with a highly precise net of straight lines, are accomplished with the help of the DATREC programme working on a guiding TPA-1001 computer with simultaneous calibration of all the six BPS-2 boards. The DATREC programme is written in the SLANG-1 language. The CALBPS programme works on CDC-1604A computer, is written in FORTRAN, and calculates transformation coefficients and corresponding precision characteristics. The work has resulted in reducing the calibration time from 10-15 min. per board to 10-15 min. per all the 6 boards. The time of accumulation in the memory TPA-1001 and of recording on the CDC-608 tape recorder of calibration data is from 3 to 5 min.; the remaining time is spent on processing on a bigger CDC-1604A computer. Examples of typical output and certain results of calibration measurements are given

  18. Present SLAC accelerator computer control system features

    International Nuclear Information System (INIS)

    Davidson, V.; Johnson, R.

    1981-02-01

    The current functional organization and state of software development of the computer control system of the Stanford Linear Accelerator is described. Included is a discussion of the distribution of functions throughout the system, the local controller features, and currently implemented features of the touch panel portion of the system. The functional use of our triplex of PDP11-34 computers sharing common memory is described. Also included is a description of the use of pseudopanel tables as data tables for closed loop control functions

  19. Investigation of computer-aided diagnosis system for bone scans: a retrospective analysis in 406 patients.

    Science.gov (United States)

    Tokuda, Osamu; Harada, Yuko; Ohishi, Yona; Matsunaga, Naofumi; Edenbrandt, Lars

    2014-05-01

    The aim of this study was to investigate the diagnostic ability of a completely automated computer-assisted diagnosis (CAD) system to detect metastases in bone scans by two patterns: one was per region, and the other was per patient. This study included 406 patients with suspected metastatic bone tumors who underwent whole-body bone scans that were analyzed by the automated CAD system. The patients were divided into four groups: a group with prostatic cancer (N = 71), breast cancer (N = 109), males with other cancers (N = 153), and females with other cancers (N = 73). We investigated the bone scan index and artificial neural network (ANN), which are parameters that can be used to classify bone scans to determine whether there are metastases. The sensitivities, specificities, positive predictive value (PPV), negative predictive value (NPV), and accuracies for the four groups were compared. Receiver operating characteristic (ROC) analyses of region-based ANN were performed to compare the diagnostic performance of the automated CAD system. There were no significant differences in the sensitivity, specificity, or NPV between the four groups. The PPVs of the group with prostatic cancer (51.0 %) were significantly higher than those of the other groups (P < 0.01). The accuracy of the group with prostatic cancer (81.5 %) was significantly higher than that of the group with breast cancer (68.6 %) and the females with other cancers (65.9 %) (P < 0.01). For the evaluation of the ROC analysis of region-based ANN, the highest Az values for the groups with prostatic cancer, breast cancer, males with other cancers, and females with other cancers were 0.82 (ANN = 0.4, 0.5, 0.6, 0.7, and 0.8), 0.83 (ANN = 0.7), 0.81 (ANN = 0.5), and 0.81 (ANN = 0.6), respectively. The special CAD system "BONENAVI" trained with a Japanese database appears to have significant potential in assisting physicians in their clinical routine. However, an improved CAD system depending on the primary lesion

  20. Investigation of computer-aided diagnosis system for bone scans. A retrospective analysis in 406 patients

    International Nuclear Information System (INIS)

    Tokuda, Osamu; Harada, Yuko; Ohishi, Yona; Matsunaga, Naofumi; Edenbrandt, L.

    2014-01-01

    The aim of this study was to investigate the diagnostic ability of a completely automated computer-assisted diagnosis (CAD) system to detect metastases in bone scans by two patterns: one was per region, and the other was per patient. This study included 406 patients with suspected metastatic bone tumors who underwent whole-body bone scans that were analyzed by the automated CAD system. The patients were divided into four groups: a group with prostatic cancer (N=71), breast cancer (N=109), males with other cancers (N=153), and females with other cancers (N=73). We investigated the bone scan index and artificial neural network (ANN), which are parameters that can be used to classify bone scans to determine whether there are metastases. The sensitivities, specificities, positive predictive value (PPV), negative predictive value (NPV), and accuracies for the four groups were compared. Receiver operating characteristic (ROC) analyses of region-based ANN were performed to compare the diagnostic performance of the automated CAD system. There were no significant differences in the sensitivity, specificity, or NPV between the four groups. The Pps of the group with prostatic cancer (51.0%) were significantly higher than those of the other groups (P < 0.01). The accuracy of the group with prostatic cancer (81.5%) was significantly higher than that of the group with breast cancer (68.6%) and the females with other cancers (65.9%) (P < 0.01). For the evaluation of the Roc analysis of region-based Ann, the highest Az values for the groups with prostatic cancer, breast cancer, males with other cancers, and females with other cancers were 0.82 (Ann=0.4, 0.5, 0.6, 0.7, and 0.8), 0.83 (Ann=0.7), 0.81 (Ann=0.5), and 0.81 (Ann=0.6), respectively. The special CAD system 'Bovine' trained with a Japanese database appears to have significant potential in assisting physicians in their clinical routine. However, an improved CAD system depending on the primary lesion of the cancer is

  1. Motion estimation for cardiac functional analysis using two x-ray computed tomography scans.

    Science.gov (United States)

    Fung, George S K; Ciuffo, Luisa; Ashikaga, Hiroshi; Taguchi, Katsuyuki

    2017-09-01

    This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise then degrades the accuracy of motion estimation. Moreover, even if the scan was performed during the sinus rhythm, the cardiac motion observed in CT images may not be cyclic with patients with atrial fibrillation. In this study, we propose to use two CT scan data, one for CT angiography at a quiescent phase at a standard dose and the other for CFA over the entire heart beat at a lower dose. We have made the following four modifications to an image-based cardiac motion estimation method we have previously developed for a full-dose retrospectively gated coronary CT angiography: (a) a full-dose prospectively gated coronary CT angiography image acquired at the least motion phase was used as the reference image; (b) a three-dimensional median filter was applied to lower-dose retrospectively gated cardiac images acquired at 20 phases over one heartbeat in order to reduce image noise; (c) the strength of the temporal regularization term was made adaptive; and (d) a one-dimensional temporal filter was applied to the estimated motion vector field in order to decrease jaggy motion patterns. We describe the conventional method iME1 and the proposed method iME2 in this article. Five observers assessed the accuracy of the estimated motion vector field of iME2 and iME1 using a 4-point scale. The observers repeated the assessment with data presented in a new random order 1 week after the first assessment session. The study confirmed that the proposed iME2 was robust against the mismatch of noise levels, contrast enhancement levels, and shapes of the chambers. There was a statistically significant difference between iME2 and iME1 (accuracy score, 2.08 ± 0.81 versus 2.77

  2. Computer applications in controlled fusion research

    International Nuclear Information System (INIS)

    Killeen, J.

    1975-01-01

    The application of computers to controlled thermonuclear research (CTR) is essential. In the near future the use of computers in the numerical modeling of fusion systems should increase substantially. A recent panel has identified five categories of computational models to study the physics of magnetically confined plasmas. A comparable number of types of models for engineering studies is called for. The development and application of computer codes to implement these models is a vital step in reaching the goal of fusion power. To meet the needs of the fusion program the National CTR Computer Center has been established at the Lawrence Livermore Laboratory. A large central computing facility is linked to smaller computing centers at each of the major CTR Laboratories by a communication network. The crucial element needed for success is trained personnel. The number of people with knowledge of plasma science and engineering trained in numerical methods and computer science must be increased substantially in the next few years. Nuclear engineering departments should encourage students to enter this field and provide the necessary courses and research programs in fusion computing

  3. Computer applications in controlled fusion research

    International Nuclear Information System (INIS)

    Killeen, J.

    1975-02-01

    The role of Nuclear Engineering Education in the application of computers to controlled fusion research can be a very important one. In the near future the use of computers in the numerical modelling of fusion systems should increase substantially. A recent study group has identified five categories of computational models to study the physics of magnetically confined plasmas. A comparable number of types of models for engineering studies are called for. The development and application of computer codes to implement these models is a vital step in reaching the goal of fusion power. In order to meet the needs of the fusion program the National CTR Computer Center has been established at the Lawrence Livermore Laboratory. A large central computing facility is linked to smaller computing centers at each of the major CTR laboratories by a communications network. The crucial element that is needed for success is trained personnel. The number of people with knowledge of plasma science and engineering that are trained in numerical methods and computer science is quite small, and must be increased substantially in the next few years. Nuclear Engineering departments should encourage students to enter this field and provide the necessary courses and research programs in fusion computing. (U.S.)

  4. Computer science approach to quantum control

    International Nuclear Information System (INIS)

    Janzing, D.

    2006-01-01

    Whereas it is obvious that every computation process is a physical process it has hardly been recognized that many complex physical processes bear similarities to computation processes. This is in particular true for the control of physical systems on the nanoscopic level: usually the system can only be accessed via a rather limited set of elementary control operations and for many purposes only a concatenation of a large number of these basic operations will implement the desired process. This concatenation is in many cases quite similar to building complex programs from elementary steps and principles for designing algorithm may thus be a paradigm for designing control processes. For instance, one can decrease the temperature of one part of a molecule by transferring its heat to the remaining part where it is then dissipated to the environment. But the implementation of such a process involves a complex sequence of electromagnetic pulses. This work considers several hypothetical control processes on the nanoscopic level and show their analogy to computation processes. We show that measuring certain types of quantum observables is such a complex task that every instrument that is able to perform it would necessarily be an extremely powerful computer. Likewise, the implementation of a heat engine on the nanoscale requires to process the heat in a way that is similar to information processing and it can be shown that heat engines with maximal efficiency would be powerful computers, too. In the same way as problems in computer science can be classified by complexity classes we can also classify control problems according to their complexity. Moreover, we directly relate these complexity classes for control problems to the classes in computer science. Unifying notions of complexity in computer science and physics has therefore two aspects: on the one hand, computer science methods help to analyze the complexity of physical processes. On the other hand, reasonable

  5. Upgrade plan for HANARO control computer system

    International Nuclear Information System (INIS)

    Kim, Min Jin; Kim, Young Ki; Jung, Hwan Sung; Choi, Young San; Woo, Jong Sub; Jun, Byung Jin

    2001-01-01

    A microprocessor based digital control system, the Multi-Loop Controller (MLC), which was chosen to control HANARO, was introduced to the market in early '80s and it had been used to control petrochemical plant, paper mill and Slowpoke reactor in Canada. Due to the development in computer technology, it has become so outdated model and the production of this model was discontinued a few years ago. Hence difficulty in acquiring the spare parts is expected. To achieve stable reactor control during its lifetime and to avoid possible technical dependency to the manufacturer, a long-term replacement plan for HANARO control computer system is on its way. The plan will include a few steps in its process. This paper briefly introduces the methods of implementation of the process and discusses the engineering activities of the plan

  6. Safety analysis of control rod drive computers

    International Nuclear Information System (INIS)

    Ehrenberger, W.; Rauch, G.; Schmeil, U.; Maertz, J.; Mainka, E.U.; Nordland, O.; Gloee, G.

    1985-01-01

    The analysis of the most significant user programmes revealed no errors in these programmes. The evaluation of approximately 82 cumulated years of operation demonstrated that the operating system of the control rod positioning processor has a reliability that is sufficiently good for the tasks this computer has to fulfil. Computers can be used for safety relevant tasks. The experience gained with the control rod positioning processor confirms that computers are not less reliable than conventional instrumentation and control system for comparable tasks. The examination and evaluation of computers for safety relevant tasks can be done with programme analysis or statistical evaluation of the operating experience. Programme analysis is recommended for seldom used and well structured programmes. For programmes with a long, cumulated operating time a statistical evaluation is more advisable. The effort for examination and evaluation is not greater than the corresponding effort for conventional instrumentation and control systems. This project has also revealed that, where it is technologically sensible, process controlling computers or microprocessors can be qualified for safety relevant tasks without undue effort. (orig./HP) [de

  7. High performance computing in linear control

    International Nuclear Information System (INIS)

    Datta, B.N.

    1993-01-01

    Remarkable progress has been made in both theory and applications of all important areas of control. The theory is rich and very sophisticated. Some beautiful applications of control theory are presently being made in aerospace, biomedical engineering, industrial engineering, robotics, economics, power systems, etc. Unfortunately, the same assessment of progress does not hold in general for computations in control theory. Control Theory is lagging behind other areas of science and engineering in this respect. Nowadays there is a revolution going on in the world of high performance scientific computing. Many powerful computers with vector and parallel processing have been built and have been available in recent years. These supercomputers offer very high speed in computations. Highly efficient software, based on powerful algorithms, has been developed to use on these advanced computers, and has also contributed to increased performance. While workers in many areas of science and engineering have taken great advantage of these hardware and software developments, control scientists and engineers, unfortunately, have not been able to take much advantage of these developments

  8. Accuracy and reliability of a novel method for fusion of digital dental casts and Cone Beam Computed Tomography scans.

    Directory of Open Access Journals (Sweden)

    Frits A Rangel

    Full Text Available Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods.

  9. Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans

    Science.gov (United States)

    Rangel, Frits A.; Maal, Thomas J. J.; Bronkhorst, Ewald M.; Breuning, K. Hero; Schols, Jan G. J. H.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2013-01-01

    Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods. PMID:23527111

  10. Robot-Arm Dynamic Control by Computer

    Science.gov (United States)

    Bejczy, Antal K.; Tarn, Tzyh J.; Chen, Yilong J.

    1987-01-01

    Feedforward and feedback schemes linearize responses to control inputs. Method for control of robot arm based on computed nonlinear feedback and state tranformations to linearize system and decouple robot end-effector motions along each of cartesian axes augmented with optimal scheme for correction of errors in workspace. Major new feature of control method is: optimal error-correction loop directly operates on task level and not on joint-servocontrol level.

  11. Configurating computer-controlled bar system

    OpenAIRE

    Šuštaršič, Nejc

    2010-01-01

    The principal goal of my diploma thesis is creating an application for configurating computer-controlled beverages dispensing systems. In the preamble of my thesis I present the theoretical platform for point of sale systems and beverages dispensing systems, which are required for the understanding of the target problematics. As with many other fields, computer tehnologies entered the field of managing bars and restaurants quite some time ago. Basic components of every bar or restaurant a...

  12. Computer-aided control system design

    International Nuclear Information System (INIS)

    Lebenhaft, J.R.

    1986-01-01

    Control systems are typically implemented using conventional PID controllers, which are then tuned manually during plant commissioning to compensate for interactions between feedback loops. As plants increase in size and complexity, such controllers can fail to provide adequate process regulations. Multivariable methods can be utilized to overcome these limitations. At the Chalk River Nuclear Laboratories, modern control systems are designed and analyzed with the aid of MVPACK, a system of computer programs that appears to the user like a high-level calculator. The software package solves complicated control problems, and provides useful insight into the dynamic response and stability of multivariable systems

  13. Is triple contrast computed tomographic scanning useful in the selective management of stab wounds to the back?

    Science.gov (United States)

    McAllister, E; Perez, M; Albrink, M H; Olsen, S M; Rosemurgy, A S

    1994-09-01

    We devised a protocol to prospectively manage stab wounds to the back with the hypothesis that the triple contrast computed tomographic (CT) scan is an effective means of detecting occult injury in these patients. All wounds to the back in hemodynamically stable adults were locally explored. All patients with muscular fascial penetration underwent triple contrast CT scanning utilizing oral, rectal, and IV contrast. Patients did not undergo surgical exploration if their CT scan was interpreted as negative or if the CT scan demonstrated injuries not requiring surgical intervention. Fifty-three patients were entered into the protocol. The time to complete the triple contrast CT scan ranged from 3 to 6 hours at a cost of $1050 for each scan. In 51 patients (96%), the CT scan either had negative findings (n = 31) or showed injuries not requiring exploration (n = 20). These patients did well with nonsurgical management. Two CT scans documented significant injury and led to surgical exploration and therapeutic celiotomies. Although triple contrast CT scanning was able to detect occult injury in patients with stab wounds to the back it did so at considerable cost and the results rarely altered clinical care. Therefore, its routine use in these patients is not recommended.

  14. Control and analysis software for a laser scanning microdensitometer

    Indian Academy of Sciences (India)

    A PC-based control software and data acquisition system is devel- oped for an existing ... Description of the system. Figure 1 shows a schematic diagram of the microdensitometer and the data acquisition system. ... ming language with very strong library functions and it also supports direct input/output programming. 5.

  15. Applying the computer code ''beam scanning' for obtaining the electron beam energy spectrum and monitoring the beam scanning system with a faraday cup and edge current sensors

    International Nuclear Information System (INIS)

    Bystrov, P.A.

    2014-01-01

    The results of experiments simulation, obtained in the development of technique for controlling the parameters of the electron beam in a compact radiation sterilization installation are presented. Calculations were performed with a help of a computer code ''BEAM SCANNING'', developed in MRTI. Proposed a method to obtain the spectrum of the electron beam by simulation the experiments in which a Faraday cup waveforms were measured. Preliminary results are presented. Also the results of the experiments and calculations obtained in the development of the amplitude angle sensors are presented. The experiments for the beam irradiation of lead plates proposed as current sensors were modeled. Results are presented in comparison with experimental data. Also are presented the simulation results for the device designed to control scanning system.

  16. ASTEC: Controls analysis for personal computers

    Science.gov (United States)

    Downing, John P.; Bauer, Frank H.; Thorpe, Christopher J.

    1989-01-01

    The ASTEC (Analysis and Simulation Tools for Engineering Controls) software is under development at Goddard Space Flight Center (GSFC). The design goal is to provide a wide selection of controls analysis tools at the personal computer level, as well as the capability to upload compute-intensive jobs to a mainframe or supercomputer. The project is a follow-on to the INCA (INteractive Controls Analysis) program that has been developed at GSFC over the past five years. While ASTEC makes use of the algorithms and expertise developed for the INCA program, the user interface was redesigned to take advantage of the capabilities of the personal computer. The design philosophy and the current capabilities of the ASTEC software are described.

  17. Computer control system of TARN-2

    International Nuclear Information System (INIS)

    Watanabe, S.

    1989-01-01

    The CAMAC interface system is employed in order to regulate the power supply, beam diagnostic and so on. Five CAMAC stations are located in the TARN-2 area and are linked with a serial highway system. The CAMAC serial highway is driven by a serial highway driver, Kinetic 3992, which is housed in the CAMAC powered crate and regulated by two successive methods. One is regulated by the mini computer through the standard branch-highway crate controller, named Type-A2, and the other is regulated with the microcomputer through the auxiliary crate controller. The CAMAC serial highway comprises the two-way optical cables with a total length of 300 m. Each CAMAC station has the serial and auxiliary crate controllers so as to realize alternative control with the local computer system. Interpreter, INSBASIC, is used in the main control computer. There are many kinds of the 'device control function' of the INSBASIC. Because the 'device control function' implies physical operating procedure of such a device, only knowledge of the logical operating procedure is required. A touch panel system is employed to regulate the complicated control flow without any knowledge of the usage of the device. A rotary encoder system, which is analogous to the potentiometer operation, is also available for smooth adjustment of the setting parameter. (author)

  18. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  19. Dosimetric study in chest computed tomography scans of adult and pediatric phantoms

    International Nuclear Information System (INIS)

    Namen A, W.; Prata M, A.; Guedes, G.

    2016-10-01

    The computed tomography scan is a radiological technique that permits an evaluation of the patient internal structures. In the last ten years, this technique has had a high growth due to clinical cases of medical emergencies, cancer and pediatric trauma. Widespread of this technique has a significant increase in the patient dose. The risk associated with the radiological examination can be considered very low compared to the natural risk. However, any additional risk, no matter how small, is unacceptable if it does not benefit the patient. To be aware of the dose distribution is important when the objective is to vary the acquisition parameters aiming a dose reduction. The aim os this study is develop a pediatric chest phantom to evaluate the dose variation in CT scans. In this work, a cylindrical adult chest phantom made in polymethyl methacrylate was used and a second chest phantom was developed, based on dimensions of in eight year old patient in oblong shape. The two simulators have 5 openings, one is central and four are peripheral lagged by 90 degrees Celsius, which allow positioning a pencil chamber aiming and observation of the dose in 5 regions. In a GE CT scanner, Discovery model and 64 channels, the central slice of both simulators were irradiated successively to obtain dose measurements using a pencil chamber. The irradiation of the central slice was conducted using the service protocol. The registered dose values showed that the pediatric phantom had higher doses especially in the anterior, posterior and central regions. The results also enabled a comparison among the index dose values obtained from the measurements with the pencil chamber. (Author)

  20. Dosimetric study in chest computed tomography scans of adult and pediatric phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Namen A, W.; Prata M, A. [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Guedes, G., E-mail: wadia.namen@gmail.com [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    The computed tomography scan is a radiological technique that permits an evaluation of the patient internal structures. In the last ten years, this technique has had a high growth due to clinical cases of medical emergencies, cancer and pediatric trauma. Widespread of this technique has a significant increase in the patient dose. The risk associated with the radiological examination can be considered very low compared to the natural risk. However, any additional risk, no matter how small, is unacceptable if it does not benefit the patient. To be aware of the dose distribution is important when the objective is to vary the acquisition parameters aiming a dose reduction. The aim os this study is develop a pediatric chest phantom to evaluate the dose variation in CT scans. In this work, a cylindrical adult chest phantom made in polymethyl methacrylate was used and a second chest phantom was developed, based on dimensions of in eight year old patient in oblong shape. The two simulators have 5 openings, one is central and four are peripheral lagged by 90 degrees Celsius, which allow positioning a pencil chamber aiming and observation of the dose in 5 regions. In a GE CT scanner, Discovery model and 64 channels, the central slice of both simulators were irradiated successively to obtain dose measurements using a pencil chamber. The irradiation of the central slice was conducted using the service protocol. The registered dose values showed that the pediatric phantom had higher doses especially in the anterior, posterior and central regions. The results also enabled a comparison among the index dose values obtained from the measurements with the pencil chamber. (Author)

  1. Refinement of clinical X-ray computed tomography (CT) scans containing metal implants.

    Science.gov (United States)

    Treece, Graham

    2017-03-01

    X-ray computed tomography (CT) data contains artefacts from many sources, with sufficient prominence to affect diagnostic utility when metal is present in the scans. These artefacts can be reduced, usually by the removal and in-filling of any sinogram data which has been affected by metal, and several such techniques have been proposed. Most of them are prone to introducing new artefacts into the CT data or may take a long time to correct the data. It is the purpose of this paper to introduce a new technique which is fast, yet can effectively remove most artefacts without introducing significant new ones. The new metal artefact reduction technique (RMAR) consists of an iterative refinement of the CT data by alternately forward- and back-projecting the part of the reconstruction near to metal. The forward-projection is corrected by making use of a prior derived from the reconstructed data which is independently estimated for each projection angle, and smoothed using a newly developed Bitonic filter. The new technique is compared with previously published (LI, NMAR, MDT) and commercial (O-MAR, IMAR) alternatives, quantitatively on phantom data, and qualitatively on a selection of clinical scans, mostly of the hip. The phantom data is from two recently published studies, enabling direct comparison with previous results. The results show an increased reduction of artefacts on the four phantom data sets tested. On two of the phantom data sets, RMAR is significantly better (pCT data, RMAR can correct each image in 3-8s, which is more than one hundred times faster than MDT. The new technique is demonstrated to have performance at least as good as MDT, with both out-performing other approaches. However, it is much faster then the latter technique, and shows better preservation of data very close to metal. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Computed Tomography Scanning and Geophysical Measurements of Core from the Coldstream 1MH Well

    Energy Technology Data Exchange (ETDEWEB)

    Crandall, Dustin M.; Brown, Sarah; Moore, Johnathan E.; Mackey, Paige E.; Paronish, Thomas J.

    2018-03-05

    The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Shale from a vertical well, the Coldstream 1MH Well in Clearfield County, PA. The core is comprised primarily of the Marcellus Shale from a depth of 7,002 to 7,176 ft.

    The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica shale formations. As part of this effort, bulk scans of core were obtained from the Coldstream 1MH well, provided by the Energy Corporation of America (now Greylock Energy). This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/coldstream-1mh-well.

    All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. En echelon fractures were observed at 7,100 ft and were CT scanned using NETL’s industrial CT scanner at higher resolution. The ability to quickly identify key areas for more detailed study with higher resolution will save time and

  3. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  4. Low cost highly available digital control computer

    International Nuclear Information System (INIS)

    Silvers, M.W.

    1986-01-01

    When designing digital controllers for critical plant control it is important to provide several features. Among these are reliability, availability, maintainability, environmental protection, and low cost. An examination of several applications has lead to a design that can be produced for approximately $20,000 (1000 control points). This design is compatible with modern concepts in distributed and hierarchical control. The canonical controller element is a dual-redundant self-checking computer that communicates with a cross-strapped, electrically isolated input/output system. The input/output subsystem comprises multiple intelligent input/output cards. These cards accept commands from the primary processor which are validated, executed, and acknowledged. Each card may be hot replaced to facilitate sparing. The implementation of the dual-redundant computer architecture is discussed. Called the FS-86, this computer can be used for a variety of applications. It has most recently found application in the upgrade of San Francisco's Bay Area Rapid Transit (BART) train control currently in progress and has been proposed for feedwater control in a boiling water reactor

  5. Characteristics of the TRISTAN control computer network

    International Nuclear Information System (INIS)

    Kurokawa, Shinichi; Akiyama, Atsuyoshi; Katoh, Tadahiko; Kikutani, Eiji; Koiso, Haruyo; Oide, Katsunobu; Shinomoto, Manabu; Kurihara, Michio; Abe, Kenichi

    1986-01-01

    Twenty-four minicomputers forming an N-to-N token-ring network control the TRISTAN accelerator complex. The computers are linked by optical fiber cables with 10 Mbps transmission speed. The software system is based on NODAL, a multicomputer interpretive language developed at the CERN SPS. The high-level services offered to the users of the network are remote execution by the EXEC, EXEC-P and IMEX commands of NODAL and uniform file access throughout the system. The network software was designed to achieve the fast response of the EXEC command. The performance of the network is also reported. Tasks that overload the minicomputers are processed on the KEK central computers. One minicomputer in the network serves as a gateway to KEKNET, which connects the minicomputer network and the central computers. The communication with the central computers is managed within the framework of the KEK NODAL system. NODAL programs communicate with the central computers calling NODAL functions; functions for exchanging data between a data set on the central computers and a NODAL variable, submitting a batch job to the central computers, checking the status of the submitted job, etc. are prepared. (orig.)

  6. SWITCHING POWER FAN CONTROL OF COMPUTER

    Directory of Open Access Journals (Sweden)

    Oleksandr I. Popovskyi

    2010-10-01

    Full Text Available Relevance of material presented in the article, due to extensive use of high-performance computers to create modern information systems, including the NAPS of Ukraine. Most computers in NAPS of Ukraine work on Intel Pentium processors at speeds from 600 MHz to 3 GHz and release a lot of heat, which requires the installation of the system unit 2-3 additional fans. The fan is always works on full power, that leads to rapid deterioration and high level (up to 50 dB noise. In order to meet ergonomic requirements it is proposed to іnstall a computer system unit and an additional control unit ventilators, allowing independent control of each fan. The solution is applied at creation of information systems planning research in the National Academy of Pedagogical Sciences of Ukraine on Internet basis.

  7. Advances in Computer, Communication, Control and Automation

    CERN Document Server

    011 International Conference on Computer, Communication, Control and Automation

    2012-01-01

    The volume includes a set of selected papers extended and revised from the 2011 International Conference on Computer, Communication, Control and Automation (3CA 2011). 2011 International Conference on Computer, Communication, Control and Automation (3CA 2011) has been held in Zhuhai, China, November 19-20, 2011. This volume  topics covered include signal and Image processing, speech and audio Processing, video processing and analysis, artificial intelligence, computing and intelligent systems, machine learning, sensor and neural networks, knowledge discovery and data mining, fuzzy mathematics and Applications, knowledge-based systems, hybrid systems modeling and design, risk analysis and management, system modeling and simulation. We hope that researchers, graduate students and other interested readers benefit scientifically from the proceedings and also find it stimulating in the process.

  8. Automatic control of commercial computer programs

    International Nuclear Information System (INIS)

    Rezvov, B.A.; Artem'ev, A.N.; Maevskij, A.G.; Demkiv, A.A.; Kirillov, B.F.; Belyaev, A.D.; Artem'ev, N.A.

    2010-01-01

    The way of automatic control of commercial computer programs is presented. The developed connection of the EXAFS spectrometer automatic system (which is managed by PC for DOS) is taken with the commercial program for the CCD detector control (which is managed by PC for Windows). The described complex system is used for the automation of intermediate amplitude spectra processing in EXAFS spectrum measurements at Kurchatov SR source

  9. Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography.

    Science.gov (United States)

    Ma, Chi; Yu, Lifeng; Chen, Baiyu; Favazza, Christopher; Leng, Shuai; McCollough, Cynthia

    2016-04-01

    Channelized Hotelling observer (CHO) models have been shown to correlate well with human observers for several phantom-based detection/classification tasks in clinical computed tomography (CT). A large number of repeated scans were used to achieve an accurate estimate of the model's template. The purpose of this study is to investigate how the experimental and CHO model parameters affect the minimum required number of repeated scans. A phantom containing 21 low-contrast objects was scanned on a 128-slice CT scanner at three dose levels. Each scan was repeated 100 times. For each experimental configuration, the low-contrast detectability, quantified as the area under receiver operating characteristic curve, [Formula: see text], was calculated using a previously validated CHO with randomly selected subsets of scans, ranging from 10 to 100. Using [Formula: see text] from the 100 scans as the reference, the accuracy from a smaller number of scans was determined. Our results demonstrated that the minimum number of repeated scans increased when the radiation dose level decreased, object size and contrast level decreased, and the number of channels increased. As a general trend, it increased as the low-contrast detectability decreased. This study provides a basis for the experimental design of task-based image quality assessment in clinical CT using CHO.

  10. Effect of variable scanning protocolson the pre-implant site evaluation of the mandible in reformatted computed tomography

    International Nuclear Information System (INIS)

    Kim, Kee Deog; Park, Chang Seo

    1999-01-01

    To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. On image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal and in horizontal measurement, there was no statistically significant difference among conventional and helical scans with pitches of 1.0, 1.5 and 2.0. In vertical measurement, there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of pre-dental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  11. Computer networks in future accelerator control systems

    International Nuclear Information System (INIS)

    Dimmler, D.G.

    1977-03-01

    Some findings of a study concerning a computer based control and monitoring system for the proposed ISABELLE Intersecting Storage Accelerator are presented. Requirements for development and implementation of such a system are discussed. An architecture is proposed where the system components are partitioned along functional lines. Implementation of some conceptually significant components is reviewed

  12. A report on ultrafast scanning methods of cerebral computed angiotomography, 2

    International Nuclear Information System (INIS)

    Fukui, Keiji; Sadamoto, Kazuhiko; Ohue, Shiro; Nakamura, Hisashi; Yamamoto, Yuji; Asari, Syoji; Kimura, Hideki; Sakaki, Saburo.

    1986-01-01

    Forty milliliters of meglumine iothalamate 282 mg iodine/ml (60 % Conray) were injected into the basilic vein at the rate of 2 ml/second through an 18 G JELCO needle. Just before the completion of the injection, dynamic scanning with table increments was performed. Three to eight scans were taken 16 - 47 seconds after the single-bolus injection of the contrast medium, while the CT number at the circle of Willis was kept high. The three following different scanning techniques were newly developed and investigated as to their clinical application: 1) Overlapping scanning: 10 mm-slice-thickness scans with 5-mm table increments can be useful for the detection of lesions in a relatively limited range, such as unruptured cerebral aneurysms. For this purpose, the overlapping axial CT scans are centered at 25, 30, and 35 mm above the canthomeatal line (CML), and the overlapping modified coronal CT scans are centered at 35, 40, and 45 mm in front of the external auditory meatus (EAM) at an approximately 60 deg angle to the CML from the occipital side. 2) Sequential scanning: 10 mm-slice-thickness scans with 10-mm table increments are applied to the diagnosis of lesions over a wide range, such as brain tumors, AVMs, and isodense chronic subdural hematomas, because this procedure can scan over a wider range with a single injection than can overlapping scanning. Thin-section sequential scanning, such as 2 mm-slice-thickness scans with 2-mm table increments, is useful for minute examinations in order to ascertain the relationship between the cerebral vessels and the surrounding structures. 3) Two-step contrast-enhanced scanning: double overlapping or sequential scannings with a contrast injection at a certain interval can be used to examine the relationship between the tumor and the abnormal vascularity in surrounding areas which have different maximum timings of enhancement. (J.P.N.)

  13. Estimation of effectiveness of automatic exposure control in computed tomograph scanner

    International Nuclear Information System (INIS)

    Akhilesh, Philomina; Sharma, S.D.; Datta, D.; Kulkarni, Arti

    2018-01-01

    With the advent of multiple detector array technology, the use of Computed Tomography (CT) scanning has increase tremendously. Computed Tomography examinations deliver relatively high radiation dose to patients in comparison with conventional radiography. It is therefore required to reduce the dose delivered in CT scans without compromising the image quality. Several parameters like applied potential, tube current, scan length, pitch etc. influence the dose delivered in CT scans. For optimization of patient dose and image quality, all modern CT scanners are enabled with Automatic Exposure Control (AEC) systems. The aim of this work is to compare the dose delivered during CT scans performed with and without AEC in order to estimate the effectiveness of AEC techniques used in CT scanners of various manufacturer

  14. Integral force feedback control with input shaping: Application to piezo-based scanning systems in ECDLs

    Science.gov (United States)

    Zhang, Meng; Liu, Zhigang; Zhu, Yu; Bu, Mingfan; Hong, Jun

    2017-07-01

    In this paper, a hybrid control system is developed by integrating the closed-loop force feedback and input shaping method to overcome the problem of the hysteresis and dynamic behavior in piezo-based scanning systems and increase the scanning speed of tunable external cavity diode lasers. The flexible hinge and piezoelectric actuators are analyzed, and a dynamic model of the scanning systems is established. A force sensor and an integral controller are utilized in integral force feedback (IFF) to directly augment the damping of the piezoelectric scanning systems. Hysteresis has been effectively eliminated, but the mechanical resonance is still evident. Noticeable residual vibration occurred after the inflection points and then gradually disappeared. For the further control of mechanical resonance, based on the theory of minimum-acceleration trajectory planning, the time-domain input shaping method was developed. The turning sections of a scanning trajectory are replaced by smooth curves, while the linear sections are retained. The IFF method is combined with the input shaping method to control the non-linearity and mechanical resonance in high-speed piezo-based scanning systems. Experiments are conducted, and the results demonstrate the effectiveness of the proposed control approach.

  15. Integral force feedback control with input shaping: Application to piezo-based scanning systems in ECDLs.

    Science.gov (United States)

    Zhang, Meng; Liu, Zhigang; Zhu, Yu; Bu, Mingfan; Hong, Jun

    2017-07-01

    In this paper, a hybrid control system is developed by integrating the closed-loop force feedback and input shaping method to overcome the problem of the hysteresis and dynamic behavior in piezo-based scanning systems and increase the scanning speed of tunable external cavity diode lasers. The flexible hinge and piezoelectric actuators are analyzed, and a dynamic model of the scanning systems is established. A force sensor and an integral controller are utilized in integral force feedback (IFF) to directly augment the damping of the piezoelectric scanning systems. Hysteresis has been effectively eliminated, but the mechanical resonance is still evident. Noticeable residual vibration occurred after the inflection points and then gradually disappeared. For the further control of mechanical resonance, based on the theory of minimum-acceleration trajectory planning, the time-domain input shaping method was developed. The turning sections of a scanning trajectory are replaced by smooth curves, while the linear sections are retained. The IFF method is combined with the input shaping method to control the non-linearity and mechanical resonance in high-speed piezo-based scanning systems. Experiments are conducted, and the results demonstrate the effectiveness of the proposed control approach.

  16. Development of 1-year-old computational phantom and calculation of organ doses during CT scans using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Pan, Yuxi; Qiu, Rui; Ge, Chaoyong; Xie, Wenzhang; Li, Junli; Gao, Linfeng; Zheng, Junzheng

    2014-01-01

    With the rapidly growing number of CT examinations, the consequential radiation risk has aroused more and more attention. The average dose in each organ during CT scans can only be obtained by using Monte Carlo simulation with computational phantoms. Since children tend to have higher radiation sensitivity than adults, the radiation dose of pediatric CT examinations requires special attention and needs to be assessed accurately. So far, studies on organ doses from CT exposures for pediatric patients are still limited. In this work, a 1-year-old computational phantom was constructed. The body contour was obtained from the CT images of a 1-year-old physical phantom and the internal organs were deformed from an existing Chinese reference adult phantom. To ensure the organ locations in the 1-year-old computational phantom were consistent with those of the physical phantom, the organ locations in 1-year-old computational phantom were manually adjusted one by one, and the organ masses were adjusted to the corresponding Chinese reference values. Moreover, a CT scanner model was developed using the Monte Carlo technique and the 1-year-old computational phantom was applied to estimate organ doses derived from simulated CT exposures. As a result, a database including doses to 36 organs and tissues from 47 single axial scans was built. It has been verified by calculation that doses of axial scans are close to those of helical scans; therefore, this database could be applied to helical scans as well. Organ doses were calculated using the database and compared with those obtained from the measurements made in the physical phantom for helical scans. The differences between simulation and measurement were less than 25% for all organs. The result shows that the 1-year-old phantom developed in this work can be used to calculate organ doses in CT exposures, and the dose database provides a method for the estimation of 1-year-old patient doses in a variety of CT examinations. (paper)

  17. Raster Scan Computer Image Generation (CIG) System Based On Refresh Memory

    Science.gov (United States)

    Dichter, W.; Doris, K.; Conkling, C.

    1982-06-01

    A full color, Computer Image Generation (CIG) raster visual system has been developed which provides a high level of training sophistication by utilizing advanced semiconductor technology and innovative hardware and firmware techniques. Double buffered refresh memory and efficient algorithms eliminate the problem of conventional raster line ordering by allowing the generated image to be stored in a random fashion. Modular design techniques and simplified architecture provide significant advantages in reduced system cost, standardization of parts, and high reliability. The major system components are a general purpose computer to perform interfacing and data base functions; a geometric processor to define the instantaneous scene image; a display generator to convert the image to a video signal; an illumination control unit which provides final image processing; and a CRT monitor for display of the completed image. Additional optional enhancements include texture generators, increased edge and occultation capability, curved surface shading, and data base extensions.

  18. Physics properties of non-helical scan using 320-row multi detector computed tomography

    International Nuclear Information System (INIS)

    Urikura, Atsushi; Nakaya, Yoshihiro; Kawatani, Keisuke; Kawashima, Ippei; Goto, Hironori; Ichikawa, Katsuhiro

    2012-01-01

    Recently, clinical applications utilizing 320-row multi detector computed tomography (320MDCT) have increased, and the physical image properties of 320MDCT have been more concerned. We evaluated the spatial resolution in scan plane and z-direction, image noise and low-contrast sensitivity of non-helical mode (320NH), 640 slices mode by a double slice reconstruction technology (640DS), and 64-row helical mode (64HE) by using a 320MDCT. The spatial resolution in z-direction was evaluated by the section sensitivity profile (SSP) measurement with the micro coin phantom and the contrast transfer ratio (CTR) with the 0.5-mm comb phantom. The in-plane spatial resolution of 320NH was uniform over all the slice positions. The spatial resolution in z-direction decreased from the cathode side toward the anode side. The image noise of the anode side was higher than that of the cathode side. The contrast to noise ratio as index of the low contrast sensitivity was uniform over all the slice position. The CTR of 320NH fluctuated in the z-position, and the fluctuation was improved by 640DS except for the center of rotation. (author)

  19. INTERNAL STRUCTURE OF A VERMICULAR IRONSTONE AS DETERMINED BY X-RAY COMPUTED TOMOGRAPHY SCANNING

    Directory of Open Access Journals (Sweden)

    Yuri Lopes Zinn

    2015-04-01

    Full Text Available Ironstones or petroplinthites are common materials in soils under humid tropical climate, generally defined as the result of Fe oxide accumulation in areas where the water table oscillates, and may exhibit considerable morphological variability. The aim of this study was to examine the internal structure and porosity of an ironstone fragment from a Petroferric Acrudox in Minas Gerais, Brazil, by computed tomography (CT and conventional techniques. The sample analyzed had total porosity of 59.5 %, with large macropores in the form of tubular channels and irregular vughs, the latter with variable degrees of infilling by material released from the ironstone walls or the soil matrix. The CT scan also showed that the ironstone has wide variation in the density of the solid phase, most likely due to higher concentrations or thick intergrowths of hematite and magnetite/maghemite, especially in its outer rims. The implications of these results for water retention and soil formation in ironstone environments are briefly discussed.

  20. Dosimetry of cone beam computed tomography scanning for diagnosis and planning in implant dentistry

    International Nuclear Information System (INIS)

    Santos Pinto de A, E. L.; Manzi, F. R.; Goncalves Z, E.; Nogueira, M. S.; Fernandes Z, M. A.

    2015-10-01

    Full text: The radiation dose and estimate the radiation induced risk of cancer and morpho functional alterations according to BEIR VII (2006) and recommendations of the ICRP 103 (2007) were measured in cone beam computed tomography (CBCT) scanning (Tc Kodak 9000C 3D) in different oral and maxillofacial regions for diagnosis and planning in implant dentistry for each examination protocol: jaw full, maxilla full and jaw and maxilla full associated. Thermoluminescent dosimeters (TLD- 100 H) were placed in an Alderson-Rando in regions corresponding to the crystalline, parotid, submandibular and thyroid glands and ovaries. The highest values for entrance skin dose were observed in the region of the parotid and submandibular glands, 9.612 mGy to 7.912 mGy and 8.818 mGy to 0.483 mGy, respectively. All examination protocols presented on the right and left sides in the region of the submandibular gland the highest values for absorbed dose (D). In the jaw full exam the thyroid glands on both sides presented highest dose values than maxilla full exam. This study allowed measuring the entrance skin dose and the absorbed dose (D) highlighting a dosimetric preponderance to the salivary glands. With danger of to radiation that induces cancer risk was observed that the age group most likely to have to risk of cancer was 20 years, compared to 30, 40, 50, 60,70 and 80 years. (Author)

  1. Portable head computed tomography scanner--technology and applications: experience with 3421 scans.

    Science.gov (United States)

    Carlson, Andrew P; Yonas, Howard

    2012-10-01

    The use of head computed tomography (CT) is standard in the management of acute brain injury; however, there are inherent risks of transport of critically ill patients. Portable CT can be brought to the patient at any location. We describe the clinical use of a portable head CT scanner (CereTom: NeuroLogica: Danvers, MA) that can be brought to the patient's bedside or to other locations such as the operating room or angiography suite. Between June of 2006 and December of 2009, a total of 3421 portable CTs were performed. A total of 3278 (95.8%) were performed in the neuroscience intensive care unit (ICU) for an average of 2.6 neuroscience ICU CT scans per day. Other locations where CTs were performed included other ICUs (n = 97), the operating room (n = 53), the emergency department (n = 1), and the angiography suite (n = 2). Most studies were non-contrasted head CT, though other modalities including xenon/CT, contrasted CT, and CT angiography were performed. Portable head CT can reliably and consistently be performed at the patient's bedside. This should lead to decreased transportation-related morbidity and improved rapid decision making in the ICU, OR, and other locations. Further studies to confirm this clinical advantage are needed. Copyright © 2011 by the American Society of Neuroimaging.

  2. External cervical resorption: an analysis using cone beam and microfocus computed tomography and scanning electron microscopy.

    Science.gov (United States)

    Gunst, V; Mavridou, A; Huybrechts, B; Van Gorp, G; Bergmans, L; Lambrechts, P

    2013-09-01

    To provide a three-dimensional representation of external cervical resorption (ECR) with microscopy, stereo microscopy, cone beam computed tomography (CT), microfocus CT and scanning electron microscopy (SEM). External cervical resorption is an aggressive form of root resorption, leading to a loss of dental hard tissues. This is due to clastic action, activated by a damage of the covering cementum and stimulated probably by infection. Clinically, it is a challenging situation as it is characterized by a late symptomatology. This is due to the pericanalar protection from a resorption-resistant sheet, composed of pre-dentine and surrounding dentine. The clastic activity is often associated with an attempt to repair, seen by the formation of osteoid tissue. Cone beam CT is extremely useful in the diagnoses and treatment planning of ECR. SEM analyses provide a better insight into the activity of osteoclasts. The root canal is surrounded by a layer of dentine that is resistant to resorption. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  3. Dosimetry of cone beam computed tomography scanning for diagnosis and planning in implant dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Santos Pinto de A, E. L.; Manzi, F. R.; Goncalves Z, E. [Pontifical Catholic University of Minas Gerais, Av. Jose Gaspar 500, 30535-901 Belo Horizonte, Minas Gerais (Brazil); Nogueira, M. S.; Fernandes Z, M. A., E-mail: madelon@cdtn.br [Development Center of Nuclear Technology / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Full text: The radiation dose and estimate the radiation induced risk of cancer and morpho functional alterations according to BEIR VII (2006) and recommendations of the ICRP 103 (2007) were measured in cone beam computed tomography (CBCT) scanning (Tc Kodak 9000C 3D) in different oral and maxillofacial regions for diagnosis and planning in implant dentistry for each examination protocol: jaw full, maxilla full and jaw and maxilla full associated. Thermoluminescent dosimeters (TLD- 100 H) were placed in an Alderson-Rando in regions corresponding to the crystalline, parotid, submandibular and thyroid glands and ovaries. The highest values for entrance skin dose were observed in the region of the parotid and submandibular glands, 9.612 mGy to 7.912 mGy and 8.818 mGy to 0.483 mGy, respectively. All examination protocols presented on the right and left sides in the region of the submandibular gland the highest values for absorbed dose (D). In the jaw full exam the thyroid glands on both sides presented highest dose values than maxilla full exam. This study allowed measuring the entrance skin dose and the absorbed dose (D) highlighting a dosimetric preponderance to the salivary glands. With danger of to radiation that induces cancer risk was observed that the age group most likely to have to risk of cancer was 20 years, compared to 30, 40, 50, 60,70 and 80 years. (Author)

  4. STEMsalabim: A high-performance computing cluster friendly code for scanning transmission electron microscopy image simulations of thin specimens

    International Nuclear Information System (INIS)

    Oelerich, Jan Oliver; Duschek, Lennart; Belz, Jürgen; Beyer, Andreas; Baranovskii, Sergei D.; Volz, Kerstin

    2017-01-01

    Highlights: • We present STEMsalabim, a modern implementation of the multislice algorithm for simulation of STEM images. • Our package is highly parallelizable on high-performance computing clusters, combining shared and distributed memory architectures. • With STEMsalabim, computationally and memory expensive STEM image simulations can be carried out within reasonable time. - Abstract: We present a new multislice code for the computer simulation of scanning transmission electron microscope (STEM) images based on the frozen lattice approximation. Unlike existing software packages, the code is optimized to perform well on highly parallelized computing clusters, combining distributed and shared memory architectures. This enables efficient calculation of large lateral scanning areas of the specimen within the frozen lattice approximation and fine-grained sweeps of parameter space.

  5. STEMsalabim: A high-performance computing cluster friendly code for scanning transmission electron microscopy image simulations of thin specimens

    Energy Technology Data Exchange (ETDEWEB)

    Oelerich, Jan Oliver, E-mail: jan.oliver.oelerich@physik.uni-marburg.de; Duschek, Lennart; Belz, Jürgen; Beyer, Andreas; Baranovskii, Sergei D.; Volz, Kerstin

    2017-06-15

    Highlights: • We present STEMsalabim, a modern implementation of the multislice algorithm for simulation of STEM images. • Our package is highly parallelizable on high-performance computing clusters, combining shared and distributed memory architectures. • With STEMsalabim, computationally and memory expensive STEM image simulations can be carried out within reasonable time. - Abstract: We present a new multislice code for the computer simulation of scanning transmission electron microscope (STEM) images based on the frozen lattice approximation. Unlike existing software packages, the code is optimized to perform well on highly parallelized computing clusters, combining distributed and shared memory architectures. This enables efficient calculation of large lateral scanning areas of the specimen within the frozen lattice approximation and fine-grained sweeps of parameter space.

  6. Computation and control with neural nets

    Energy Technology Data Exchange (ETDEWEB)

    Corneliusen, A.; Terdal, P.; Knight, T.; Spencer, J.

    1989-10-04

    As energies have increased exponentially with time so have the size and complexity of accelerators and control systems. NN may offer the kinds of improvements in computation and control that are needed to maintain acceptable functionality. For control their associative characteristics could provide signal conversion or data translation. Because they can do any computation such as least squares, they can close feedback loops autonomously to provide intelligent control at the point of action rather than at a central location that requires transfers, conversions, hand-shaking and other costly repetitions like input protection. Both computation and control can be integrated on a single chip, printed circuit or an optical equivalent that is also inherently faster through full parallel operation. For such reasons one expects lower costs and better results. Such systems could be optimized by integrating sensor and signal processing functions. Distributed nets of such hardware could communicate and provide global monitoring and multiprocessing in various ways e.g. via token, slotted or parallel rings (or Steiner trees) for compatibility with existing systems. Problems and advantages of this approach such as an optimal, real-time Turing machine are discussed. Simple examples are simulated and hardware implemented using discrete elements that demonstrate some basic characteristics of learning and parallelism. Future microprocessors' are predicted and requested on this basis. 19 refs., 18 figs.

  7. Computation and control with neural nets

    International Nuclear Information System (INIS)

    Corneliusen, A.; Terdal, P.; Knight, T.; Spencer, J.

    1989-01-01

    As energies have increased exponentially with time so have the size and complexity of accelerators and control systems. NN may offer the kinds of improvements in computation and control that are needed to maintain acceptable functionality. For control their associative characteristics could provide signal conversion or data translation. Because they can do any computation such as least squares, they can close feedback loops autonomously to provide intelligent control at the point of action rather than at a central location that requires transfers, conversions, hand-shaking and other costly repetitions like input protection. Both computation and control can be integrated on a single chip, printed circuit or an optical equivalent that is also inherently faster through full parallel operation. For such reasons one expects lower costs and better results. Such systems could be optimized by integrating sensor and signal processing functions. Distributed nets of such hardware could communicate and provide global monitoring and multiprocessing in various ways e.g. via token, slotted or parallel rings (or Steiner trees) for compatibility with existing systems. Problems and advantages of this approach such as an optimal, real-time Turing machine are discussed. Simple examples are simulated and hardware implemented using discrete elements that demonstrate some basic characteristics of learning and parallelism. Future 'microprocessors' are predicted and requested on this basis. 19 refs., 18 figs

  8. National Ignition Facility integrated computer control system

    International Nuclear Information System (INIS)

    Van Arsdall, P.J. LLNL

    1998-01-01

    The NIF design team is developing the Integrated Computer Control System (ICCS), which is based on an object-oriented software framework applicable to event-driven control systems. The framework provides an open, extensible architecture that is sufficiently abstract to construct future mission-critical control systems. The ICCS will become operational when the first 8 out of 192 beams are activated in mid 2000. The ICCS consists of 300 front-end processors attached to 60,000 control points coordinated by a supervisory system. Computers running either Solaris or VxWorks are networked over a hybrid configuration of switched fast Ethernet and asynchronous transfer mode (ATM). ATM carries digital motion video from sensors to operator consoles. Supervisory software is constructed by extending the reusable framework components for each specific application. The framework incorporates services for database persistence, system configuration, graphical user interface, status monitoring, event logging, scripting language, alert management, and access control. More than twenty collaborating software applications are derived from the common framework. The framework is interoperable among different kinds of computers and functions as a plug-in software bus by leveraging a common object request brokering architecture (CORBA). CORBA transparently distributes the software objects across the network. Because of the pivotal role played, CORBA was tested to ensure adequate performance

  9. CANDU Digital Control Computer upgrade options

    International Nuclear Information System (INIS)

    De Jong, M.S.; De Grosbois, J.; Qian, T.

    1997-01-01

    This paper reviews the evolution of Digital Control Computers (DCC) in CANDU power plants to the present day. Much of this evolution has been to meeting changing control or display requirements as well as the replacement of obsolete, or old and less reliable technology with better equipment that is now available. The current work at AECL and Canadian utilities to investigate DCC upgrade options, alternatives, and strategies are examined. The dependence of a particular upgrade strategy on the overall plant refurbishment plans are also discussed. Presently, the upgrade options range from replacement of individual obsolete system components, to replacement of the entire DCC hardware without changing the software, to complete replacement of the DCCs with a functionally equivalent system using new control computer equipment and software. Key issues, constraints and objectives associated with these DCC upgrade options are highlighted. (author)

  10. Intermittent control: a computational theory of human control.

    Science.gov (United States)

    Gawthrop, Peter; Loram, Ian; Lakie, Martin; Gollee, Henrik

    2011-02-01

    The paradigm of continuous control using internal models has advanced understanding of human motor control. However, this paradigm ignores some aspects of human control, including intermittent feedback, serial ballistic control, triggered responses and refractory periods. It is shown that event-driven intermittent control provides a framework to explain the behaviour of the human operator under a wider range of conditions than continuous control. Continuous control is included as a special case, but sampling, system matched hold, an intermittent predictor and an event trigger allow serial open-loop trajectories using intermittent feedback. The implementation here may be described as "continuous observation, intermittent action". Beyond explaining unimodal regulation distributions in common with continuous control, these features naturally explain refractoriness and bimodal stabilisation distributions observed in double stimulus tracking experiments and quiet standing, respectively. Moreover, given that human control systems contain significant time delays, a biological-cybernetic rationale favours intermittent over continuous control: intermittent predictive control is computationally less demanding than continuous predictive control. A standard continuous-time predictive control model of the human operator is used as the underlying design method for an event-driven intermittent controller. It is shown that when event thresholds are small and sampling is regular, the intermittent controller can masquerade as the underlying continuous-time controller and thus, under these conditions, the continuous-time and intermittent controller cannot be distinguished. This explains why the intermittent control hypothesis is consistent with the continuous control hypothesis for certain experimental conditions.

  11. Brian Carpenter at the PS control computer

    CERN Multimedia

    vmo; CERN PhotoLab

    1971-01-01

    Brian E. Carpenter has been Group Leader of the Communications Systems group at CERN since 1985, following ten years' experience in software for process control systems at CERN, which was interrupted by three years teaching undergraduate computer science at Massey University in New Zealand. He holds a first degree in physics and a Ph.D. in computer science, and is an M.I.E.E. He is Chair of the Internet Architecture Board and an active participant in the Internet Engineering Task Force.

  12. Development of scan analysis techniques employing a small computer. Final report, February 1, 1963--July 31, 1976

    International Nuclear Information System (INIS)

    Kuhl, D.E.

    1976-01-01

    During the thirteen year duration of this contract the goal has been to develop and apply computer based analysis of radionuclide scan data so as to make available improved diagnostic information based on a knowledge of localized quantitative estimates of radionuclide concentration. Results are summarized

  13. Use of computed tomographic scanning and embolization to improve the nonoperative management of splenic trauma: critically appraised topic

    International Nuclear Information System (INIS)

    Elliott, J.E.; Millward, S.F.; Kribs, S.W.

    2003-01-01

    A patient with a grade 3 splenic laceration, who was stable and being treated with nonoperative management (NOM) underwent contrast-enhancement abdominal computed tomography (CT) 3 days after the injury. The scan showed a 2-cm well-defined hyperdense contrast collection within the splenic laceration. (author)

  14. Use of computed tomographic scanning and embolization to improve the nonoperative management of splenic trauma: critically appraised topic

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, J.E.; Millward, S.F.; Kribs, S.W. [Univ. of Western Ontario, London Health Services Centre, London, Ontario (Canada)

    2003-06-01

    A patient with a grade 3 splenic laceration, who was stable and being treated with nonoperative management (NOM) underwent contrast-enhancement abdominal computed tomography (CT) 3 days after the injury. The scan showed a 2-cm well-defined hyperdense contrast collection within the splenic laceration. (author)

  15. Accuracy and reliability of a novel method for fusion of digital dental casts and cone beam computed tomography scans

    NARCIS (Netherlands)

    Rangel, F.A.; Maal, T.J.J.; Bronkhorst, E.M.; Breuning, K.H.; Schols, J.G.J.H.; Berge, S.J.; Kuijpers-Jagtman, A.M.

    2013-01-01

    Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental

  16. PREDICTING CHEMICAL REACTIVITY OF HUMIC SUBSTANCES FOR MINERALS AND XENOBIOTICS: USE OF COMPUTATIONAL CHEMISTRY, SCANNING PROBE MICROSCOPY AND VIRTUAL REALITY

    Science.gov (United States)

    In this chapter we review the literature on scanning probe microscopy (SPM), virtual reality (VR), and computational chemistry and our earlier work dealing with modeling lignin, lignin-carbohydrate complexes (LCC), humic substances (HSs) and non-bonded organo-mineral interactions...

  17. Development of scan analysis techniques employing a small computer. Final report, February 1, 1963--July 31, 1976

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.

    1976-08-05

    During the thirteen year duration of this contract the goal has been to develop and apply computer based analysis of radionuclide scan data so as to make available improved diagnostic information based on a knowledge of localized quantitative estimates of radionuclide concentration. Results are summarized. (CH)

  18. Integrated Computer Controlled Glow Discharge Tube

    Science.gov (United States)

    Kaiser, Erik; Post-Zwicker, Andrew

    2002-11-01

    An "Interactive Plasma Display" was created for the Princeton Plasma Physics Laboratory to demonstrate the characteristics of plasma to various science education outreach programs. From high school students and teachers, to undergraduate students and visitors to the lab, the plasma device will be a key component in advancing the public's basic knowledge of plasma physics. The device is fully computer controlled using LabVIEW, a touchscreen Graphical User Interface [GUI], and a GPIB interface. Utilizing a feedback loop, the display is fully autonomous in controlling pressure, as well as in monitoring the safety aspects of the apparatus. With a digital convectron gauge continuously monitoring pressure, the computer interface analyzes the input signals, while making changes to a digital flow controller. This function works independently of the GUI, allowing the user to simply input and receive a desired pressure; quickly, easily, and intuitively. The discharge tube is a 36" x 4"id glass cylinder with 3" side port. A 3000 volt, 10mA power supply, is used to breakdown the plasma. A 300 turn solenoid was created to demonstrate the magnetic pinching of a plasma. All primary functions of the device are controlled through the GUI digital controllers. This configuration allows for operators to safely control the pressure (100mTorr-1Torr), magnetic field (0-90Gauss, 7amps, 10volts), and finally, the voltage applied across the electrodes (0-3000v, 10mA).

  19. Automated high speed volume computed tomography for inline quality control

    International Nuclear Information System (INIS)

    Hanke, R.; Kugel, A.; Troup, P.

    2004-01-01

    Increasing complexity of innovative products as well as growing requirements on quality and reliability call for more detailed knowledge about internal structures of manufactured components rather by 100 % inspection than just by sampling test. A first-step solution, like radioscopic inline inspection machines, equipped with automated data evaluation software, have become state of the art in the production floor during the last years. However, these machines provide just ordinary two-dimensional information and deliver no volume data e.g. to evaluate exact position or shape of detected defects. One way to solve this problem is the application of X-ray computed tomography (CT). Compared to the performance of the first generation medical scanners (scanning times of many hours), today, modern Volume CT machines for industrial applications need about 5 minutes for a full object scan depending on the object size. Of course, this is still too long to introduce this powerful method into the inline production quality control. In order to gain acceptance, the scanning time including subsequent data evaluation must be decreased significantly and adapted to the manufacturing cycle times. This presentation demonstrates the new technical set up, reconstruction results and the methods for high-speed volume data evaluation of a new fully automated high-speed CT scanner with cycle times below one minute for an object size of less than 15 cm. This will directly create new opportunities in design and construction of more complex objects. (author)

  20. Future Computer, Communication, Control and Automation

    CERN Document Server

    2011 International Conference on Computer, Communication, Control and Automation

    2012-01-01

    The volume includes a set of selected papers extended and revised from the 2011 International Conference on Computer, Communication, Control and Automation (3CA 2011). 2011 International Conference on Computer, Communication, Control and Automation (3CA 2011) has been held in Zhuhai, China, November 19-20, 2011. This volume topics covered include wireless communications, advances in wireless video, wireless sensors networking, security in wireless networks, network measurement and management, hybrid and discrete-event systems, internet analytics and automation, robotic system and applications, reconfigurable automation systems, machine vision in automation. We hope that researchers, graduate students and other interested readers benefit scientifically from the proceedings and also find it stimulating in the process.

  1. Cemento-Osseous Dysplasias: Imaging Features Based on Cone Beam Computed Tomography Scans.

    Science.gov (United States)

    Cavalcanti, Paulo Henrique Pereira; Nascimento, Eduarda Helena Leandro; Pontual, Maria Luiza Dos Anjos; Pontual, Andréa Dos Anjos; Marcelos, Priscylla Gonçalves Correia Leite de; Perez, Danyel Elias da Cruz; Ramos-Perez, Flávia Maria de Moraes

    2018-01-01

    Imaging exams have important role in diagnosis of cemento-osseous dysplasia (COD). Cone beam computed tomography (CBCT) stands out for allowing three-dimensional image evaluation. This study aimed to assess the prevalence of cases diagnosed as COD on CBCT scans, as well identify the main imaging features related to these lesions. An analysis was performed in a database containing 22,400 radiological reports, in which all cases showing some type of COD were initially selected. These CBCT exams were reevaluated to confirm the radiographic diagnosis and determine the prevalence and distribution of the types of COD with regard to gender, age and preferred location, while describing its most common imaging aspects. Data were presented using descriptive analyses. There were 82 cases diagnosed as COD in the CBCT images (prevalence of 0.4%). The distribution of patients was 11 (13.4%) male and 71 (86.6%) female, with a mean age of 49.8 years (age-range 17-85 years). There were 47 (57.3%) cases of periapical COD, 23 (28%) of focal COD and 12 (14.6%) of florid COD. The mandible was more affected than the maxilla. In most cases, the lesions were mixed or hyperdense. All COD had well-defined limits and there were no cases of tooth displacement. In conclusion, periapical COD was the most common type and the most affected bone was the mandible. Imaging evaluation is critical for diagnosis and dentists should bear in mind all possible radiographic presentations of COD in order to prevent misleading diagnoses and consequently, inadequate treatments.

  2. Computer control of rf at SLAC

    International Nuclear Information System (INIS)

    Schwarz, H.D.

    1985-03-01

    The Stanford Linear Accelerator is presently upgraded for the SLAC Linear Collider project. The energy is to be increased from approximately 31 GeV to 50 GeV. Two electron beams and one positron beam are to be accelerated with high demands on the quality of the beams. The beam specifications are shown. To meet these specifications, all parameters influencing the beams have to be under tight control and continuous surveillance. This task is accomplished by a new computer system implemented at SLAC which has, among many other functions, control over rf accelerating fields. 13 refs., 8 figs., 2 tabs

  3. Universal dephasing control during quantum computation

    International Nuclear Information System (INIS)

    Gordon, Goren; Kurizki, Gershon

    2007-01-01

    Dephasing is a ubiquitous phenomenon that leads to the loss of coherence in quantum systems and the corruption of quantum information. We present a universal dynamical control approach to combat dephasing during all stages of quantum computation, namely, storage and single- and two-qubit operators. We show that (a) tailoring multifrequency gate pulses to the dephasing dynamics can increase fidelity; (b) cross-dephasing, introduced by entanglement, can be eliminated by appropriate control fields; (c) counterintuitively and contrary to previous schemes, one can increase the gate duration, while simultaneously increasing the total gate fidelity

  4. Interaction and control in wearable computing

    International Nuclear Information System (INIS)

    Strand, Ole Morten; Johansen, Paal; Droeivoldsmo, Asgeir; Reigstad, Magnus; Olsen, Asle; Helgar, Stein

    2004-03-01

    This report presents the status of Halden Virtual Reality Centre (HVRC) work with technological solutions for wearable computing to support operations where interaction and control of wearable information and communication systems for plant floor personnel are of importance. The report describes a framework and system prototype developed for testing technology, usability and applicability of eye movements and speech for controlling wearable equipment while having both hands free. Potentially interesting areas for further development are discussed with regard to the effect they have on the work situation for plant floor personnel using computerised wearable systems. (Author)

  5. Picture processing computer to control movement by computer provided vision

    Energy Technology Data Exchange (ETDEWEB)

    Graefe, V

    1983-01-01

    The author introduces a multiprocessor system which has been specially developed to enable mechanical devices to interpret pictures presented in real time. The separate processors within this system operate simultaneously and independently. By means of freely moveable windows the processors can concentrate on those parts of the picture that are relevant to the control problem. If a machine is to make a correct response to its observation of a picture of moving objects, it must be able to follow the picture sequence, step by step, in real time. As the usual serially operating processors are too slow for such a task, the author describes three models of a special picture processing computer which it has been necessary to develop. 3 references.

  6. Trends and patterns of computed tomography scan use among children in The Netherlands: 1990-2012

    International Nuclear Information System (INIS)

    Meulepas, Johanna M.; Gradowska, Patrycja; Kieft, Mariette; Hauptmann, Michael; Smets, Anne M.J.B.; Nievelstein, Rutger A.J.; Verbeke, Jonathan; Holscher, Herma C.; Rutten, Matthieu J.C.M.; Ronckers, Cecile M.

    2017-01-01

    To evaluate trends and patterns in CT usage among children (aged 0-17 years) in The Netherlands during the period 1990-2012. Lists of electronically archived paediatric CT scans were requested from the Radiology Information Systems (RIS) of Dutch hospitals which reported >10 paediatric CT scans annually in a survey conducted in 2010. Data included patient identification, birth date, gender, scan date and body part scanned. For non-participating hospitals and for years prior to electronic archiving in some participating hospitals, data were imputed by calendar year and hospital type (academic, general with <500 beds, general with ≥ 500 beds). Based on 236,066 CT scans among 146,368 patients performed between 1990 and 2012, estimated annual numbers of paediatric CT scans in The Netherlands increased from 7,731 in 1990 to 26,023 in 2012. More than 70 % of all scans were of the head and neck. During the last decade, substantial increases of more than 5 % per year were observed in general hospitals with fewer than 500 beds and among children aged 10 years or older. The estimated number of paediatric CT scans has more than tripled in The Netherlands during the last two decades. (orig.)

  7. Trends and patterns of computed tomography scan use among children in The Netherlands: 1990-2012

    Energy Technology Data Exchange (ETDEWEB)

    Meulepas, Johanna M.; Gradowska, Patrycja; Kieft, Mariette; Hauptmann, Michael [Netherlands Cancer Institute, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Smets, Anne M.J.B. [Academic Medical Center Amsterdam, Department of Radiology, Amsterdam (Netherlands); Nievelstein, Rutger A.J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Verbeke, Jonathan [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Holscher, Herma C. [HAGA Hospital/Juliana Children' s Hospital, Department of Radiology, The Hague (Netherlands); Rutten, Matthieu J.C.M. [Jeroen Bosch Hospital, Department of Radiology, ' s Hertogenbosch (Netherlands); Ronckers, Cecile M. [Academic Medical Center Amsterdam, Department of Paediatric Oncology Emma Children' s Hospital, Amsterdam (Netherlands)

    2017-06-15

    To evaluate trends and patterns in CT usage among children (aged 0-17 years) in The Netherlands during the period 1990-2012. Lists of electronically archived paediatric CT scans were requested from the Radiology Information Systems (RIS) of Dutch hospitals which reported >10 paediatric CT scans annually in a survey conducted in 2010. Data included patient identification, birth date, gender, scan date and body part scanned. For non-participating hospitals and for years prior to electronic archiving in some participating hospitals, data were imputed by calendar year and hospital type (academic, general with <500 beds, general with ≥ 500 beds). Based on 236,066 CT scans among 146,368 patients performed between 1990 and 2012, estimated annual numbers of paediatric CT scans in The Netherlands increased from 7,731 in 1990 to 26,023 in 2012. More than 70 % of all scans were of the head and neck. During the last decade, substantial increases of more than 5 % per year were observed in general hospitals with fewer than 500 beds and among children aged 10 years or older. The estimated number of paediatric CT scans has more than tripled in The Netherlands during the last two decades. (orig.)

  8. Computer controls for the WITCH experiment

    CERN Document Server

    Tandecki, M; Van Gorp, S; Friedag, P; De Leebeeck, V; Beck, D; Brand, H; Weinheimer, C; Breitenfeldt, M; Traykov, E; Mader, J; Roccia, S; Severijns, N; Herlert, A; Wauters, F; Zakoucky, D; Kozlov, V; Soti, G

    2011-01-01

    The WITCH experiment is a medium-scale experimental set-up located at ISOLDE/CERN. It combines a double Penning trap system with,a retardation spectrometer for energy measurements of recoil ions from beta decay. For a correct operation of such a set-up a whole range of different devices is required. Along with the installation and optimization of the set-up a computer control system was developed to control these devices. The CS-Framework that is developed and maintained at GSI, was chosen as a basis for this control system as it is perfectly suited to handle the distributed nature of a control system.We report here on the required hardware for WITCH, along with the basis of this CS-Framework and the add-ons that were implemented for WITCH. (C) 2010 Elsevier B.V. All rights reserved.

  9. Is direct radiologist supervision of abdominal computed tomography (CT) scans necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Goh, V. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood (United Kingdom); Halligan, S. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom)]. E-mail: s.halligan@imperial.ac.uk; Anderson, J.M. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Hugill, J. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Leonard, A. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom)

    2005-07-01

    AIM: To determine the effect of direct radiological supervision of patients attending for abdominal CT by assessing the frequency of protocol alteration subsequent to radiologist review of the images obtained. MATERIALS AND METHODS: A prospective questionnaire-based observational study was performed of 187 consecutive patients undergoing abdominal CT. The CT protocol was determined by a radiologist in advance, with reference to the request form. Any subsequent change in the prescribed study that was contingent on radiologist review of the images obtained was documented on the questionnaire. Comparison was made with a second (control) group of 100 patients undergoing cranial CT. RESULTS: A protocol change was undertaken following radiologist review of the CT images of 17 (9%) of the group undergoing abdominal CT, compared with 14 (14%) of the group undergoing cranial CT. In the abdominal CT group, further scanning was performed for lesion characterization, to guide a subsequent interventional procedure, because of inadequate anatomical coverage or to evaluate an unexpected lung tumour. There was no significant difference in proportions between the two groups (p=0.23). CONCLUSION: When abdominal and cranial CT studies were compared, there was no significant difference in the proportion of studies requiring a change in the prescribed protocol following radiologist review of the images obtained. There was no evidence to suggest that abdominal CT was any less suited to protocol.

  10. A 4D dose computation method to investigate motion interplay effects in scanned ion beam prostate therapy

    International Nuclear Information System (INIS)

    Ammazzalorso, F; Jelen, U

    2014-01-01

    In particle therapy, the interplay between beam scanning and target motion during treatment delivery may result in dose deterioration. Interplay effects have been studied for targets exhibiting periodic respiratory motion, however, they are not well understood for irregular motion patterns, such as those exhibited by the prostate. In this note, we propose and validate a 4D dose computation method, which enables estimation of effective dose delivered to the prostate by scanning ion beams in presence of intrafraction motion, as well as facilitates investigation of various motion interplay countermeasures. (note)

  11. Unusual cause for recurrent Cushing syndrome and its diagnosis by computed tomography and NP-59 radiocholesterol scanning

    International Nuclear Information System (INIS)

    Harris, R.D.; Herwig, K.R.

    1990-01-01

    Cushing syndrome can recur following an adrenalectomy. One of the primary causes is recurrence of adrenal carcinoma either locally or from metastases. Hyperplasia and hyperfunction of adrenal remnants may also occur if there is pituitary stimulation. We have a patient in whom recurrent Cushing syndrome developed from small nonmalignant deposits of adrenal tissue in the perirenal adipose tissue following adrenalectomy of a benign adenoma. These deposits were identifiable by computed tomography. A false-negative NP-59 iodocholesterol scan was instructive in pointing out some problems in the interpretation of this type of scan for adrenal tissue

  12. Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull.

    Science.gov (United States)

    Berco, Mauricio; Rigali, Paul H; Miner, R Matthew; DeLuca, Stephelynn; Anderson, Nina K; Will, Leslie A

    2009-07-01

    The purpose of this study was to determine the accuracy and reliability of 3-dimensional craniofacial measurements obtained from cone-beam computed tomography (CBCT) scans of a dry human skull. Seventeen landmarks were identified on the skull. CBCT scans were then obtained, with 2 skull orientations during scanning. Twenty-nine interlandmark linear measurements were made directly on the skull and compared with the same measurements made on the CBCT scans. All measurements were made by 2 operators on 4 separate occasions. The method errors were 0.19, 0.21, and 0.19 mm in the x-, y- and z-axes, respectively. Repeated measures analysis of variance (ANOVA) showed no significant intraoperator or interoperator differences. The mean measurement error was -0.01 mm (SD, 0.129 mm). Five measurement errors were found to be statistically significantly different; however, all measurement errors were below the known voxel size and clinically insignificant. No differences were found in the measurements from the 2 CBCT scan orientations of the skull. CBCT allows for clinically accurate and reliable 3-dimensional linear measurements of the craniofacial complex. Moreover, skull orientation during CBCT scanning does not affect the accuracy or the reliability of these measurements.

  13. Distributed computer control system for reactor optimization

    International Nuclear Information System (INIS)

    Williams, A.H.

    1983-01-01

    At the Oldbury power station a prototype distributed computer control system has been installed. This system is designed to support research and development into improved reactor temperature control methods. This work will lead to the development and demonstration of new optimal control systems for improvement of plant efficiency and increase of generated output. The system can collect plant data from special test instrumentation connected to dedicated scanners and from the station's existing data processing system. The system can also, via distributed microprocessor-based interface units, make adjustments to the desired reactor channel gas exit temperatures. The existing control equipment will then adjust the height of control rods to maintain operation at these temperatures. The design of the distributed system is based on extensive experience with distributed systems for direct digital control, operator display and plant monitoring. The paper describes various aspects of this system, with particular emphasis on: (1) the hierarchal system structure; (2) the modular construction of the system to facilitate installation, commissioning and testing, and to reduce maintenance to module replacement; (3) the integration of the system into the station's existing data processing system; (4) distributed microprocessor-based interfaces to the reactor controls, with extensive security facilities implemented by hardware and software; (5) data transfer using point-to-point and bussed data links; (6) man-machine communication based on VDUs with computer input push-buttons and touch-sensitive screens; and (7) the use of a software system supporting a high-level engineer-orientated programming language, at all levels in the system, together with comprehensive data link management

  14. Manufacturing and application of micro computer for control

    International Nuclear Information System (INIS)

    Park, Seung Man; Heo, Gyeong; Yun, Jun Young

    1990-05-01

    This book deals with machine code and assembly program for micro computer. It composed of 20 chapters, which are micro computer system, practice of a storage cell, manufacturing 1 of micro computer, manufacturing 2 of micro computer, manufacturing of micro computer AID-80A, making of machine language, interface like Z80-PIO and 8255A(PPI), counter and timer interface, exercise of basic command, arithmetic operation, arrangement operation, an indicator control, music playing, detection of input of PIO. control of LED of PIO, PIO mode, CTC control by micro computer, SIO control by micro computer and application by micro computer.

  15. Fan-beam scanning laser optical computed tomography for large volume dosimetry

    Science.gov (United States)

    Dekker, K. H.; Battista, J. J.; Jordan, K. J.

    2017-05-01

    A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations.

  16. Fan-beam scanning laser optical computed tomography for large volume dosimetry

    International Nuclear Information System (INIS)

    Dekker, K H; Battista, J J; Jordan, K J

    2017-01-01

    A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations. (paper)

  17. Feedback/feedforward control of hysteresis-compensated piezoelectric actuators for high-speed scanning applications

    International Nuclear Information System (INIS)

    Liu, Yanfang; Shan, Jinjun; Gabbert, Ulrich

    2015-01-01

    This paper presents the control system design for a piezoelectric actuator (PEA) for a high-speed trajectory scanning application. First nonlinear hysteresis is compensated for by using the Maxwell resistive capacitor model. Then the linear dynamics of the hysteresis-compensated piezoelectric actuator are identified. A proportional plus integral (PI) controller is designed based on the linear system, enhanced by feedforward hysteresis compensation. It is found that the feedback controller does not always improve tracking accuracy. When the input frequency exceeds a certain value, feedforward control only may result in better control performance. Experiments are conducted, and the results demonstrate the effectiveness of the proposed control approach. (paper)

  18. Early Chest Computed Tomography Scan to Assist Diagnosis and Guide Treatment Decision for Suspected Community-acquired Pneumonia.

    Science.gov (United States)

    Claessens, Yann-Erick; Debray, Marie-Pierre; Tubach, Florence; Brun, Anne-Laure; Rammaert, Blandine; Hausfater, Pierre; Naccache, Jean-Marc; Ray, Patrick; Choquet, Christophe; Carette, Marie-France; Mayaud, Charles; Leport, Catherine; Duval, Xavier

    2015-10-15

    Clinical decision making relative to community-acquired pneumonia (CAP) diagnosis is difficult. Chest radiograph is key in establishing parenchymal lung involvement. However, radiologic performance may lead to misdiagnosis, rendering questionable the use of chest computed tomography (CT) scan in patients with clinically suspected CAP. To assess whether early multidetector chest CT scan affects diagnosis and management of patients visiting the emergency department with suspected CAP. A total of 319 prospectively enrolled patients with clinically suspected CAP underwent multidetector chest CT scan within 4 hours. CAP diagnosis probability (definite, probable, possible, or excluded) and therapeutic plans (antibiotic initiation/discontinuation, hospitalization/discharge) were established by emergency physicians before and after CT scan results. The adjudication committee established the final CAP classification on Day 28. Chest radiograph revealed a parenchymal infiltrate in 188 patients. CAP was initially classified as definite in 143 patients (44.8%), probable or possible in 172 (53.8%), and excluded in 4 (1.2%). CT scan revealed a parenchymal infiltrate in 40 (33%) of the patients without infiltrate on chest radiograph and excluded CAP in 56 (29.8%) of the 188 with parenchymal infiltrate on radiograph. CT scan modified classification in 187 (58.6%; 95% confidence interval, 53.2-64.0), leading to 50.8% definite CAP and 28.8% excluded CAP, and 80% of modifications were in accordance with adjudication committee classification. Because of CT scan, antibiotics were initiated in 51 (16%) and discontinued in 29 (9%), and hospitalization was decided in 22 and discharge in 23. In CAP-suspected patients visiting the emergency unit, early CT scan findings complementary to chest radiograph markedly affect both diagnosis and clinical management. Clinical trial registered with www.clinicaltrials.gov (NCT 01574066).

  19. Systematic control of large computer programs

    International Nuclear Information System (INIS)

    Goedbloed, J.P.; Klieb, L.

    1986-07-01

    A package of CCL, UPDATE, and FORTRAN procedures is described which facilitates the systematic control and development of large scientific computer programs. The package provides a general tool box for this purpose which contains many conveniences for the systematic administration of files, editing, reformating of line printer output files, etc. In addition, a small number of procedures is devoted to the problem of structured development of a large computer program which is used by a group of scientists. The essence of the method is contained in three procedures N, R, and X for the creation of a new UPDATE program library, its revision, and execution, resp., and a procedure REVISE which provides a joint editor - UPDATE session which combines the advantages of the two systems, viz. speed and rigor. (Auth.)

  20. Radiology of pulmonary disease. Chest radiography, computed tomography, and gallium scanning

    International Nuclear Information System (INIS)

    Golden, J.A.; Sollitto, R.A.

    1988-01-01

    A review of the radiologic manifestations of AIDS pulmonary diseases, with an emphasis on the utility of gallium scanning in the context of the normal or equivocal chest x-ray, is presented.99 references

  1. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  2. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  3. Trends and patterns of computed tomography scan use among children in The Netherlands: 1990-2012.

    Science.gov (United States)

    Meulepas, Johanna M; Smets, Anne M J B; Nievelstein, Rutger A J; Gradowska, Patrycja; Verbeke, Jonathan; Holscher, Herma C; Rutten, Matthieu J C M; Kieft, Mariëtte; Ronckers, Cécile M; Hauptmann, Michael

    2017-06-01

    To evaluate trends and patterns in CT usage among children (aged 0-17 years) in The Netherlands during the period 1990-2012. Lists of electronically archived paediatric CT scans were requested from the Radiology Information Systems (RIS) of Dutch hospitals which reported >10 paediatric CT scans annually in a survey conducted in 2010. Data included patient identification, birth date, gender, scan date and body part scanned. For non-participating hospitals and for years prior to electronic archiving in some participating hospitals, data were imputed by calendar year and hospital type (academic, general with Netherlands increased from 7,731 in 1990 to 26,023 in 2012. More than 70 % of all scans were of the head and neck. During the last decade, substantial increases of more than 5 % per year were observed in general hospitals with fewer than 500 beds and among children aged 10 years or older. The estimated number of paediatric CT scans has more than tripled in The Netherlands during the last two decades. • Paediatric CT in The Netherlands has tripled during the last two decades. • The number of paediatric CTs increased through 2012 in general hospitals. • Paediatric CTs continued to increase among children aged 10 years or older.

  4. Tools for remote computing in accelerator control

    International Nuclear Information System (INIS)

    Anderssen, P.S.; Frammery, V.; Wilcke, R.

    1990-01-01

    In modern accelerator control systems, the intelligence of the equipment is distributed in the geographical and the logical sense. Control processes for a large variety of tasks reside in both the equipment and the control computers. Hence successful operation hinges on the availability and reliability of the communication infrastructure. The computers are interconnected by a communication system and use remote procedure calls and message passing for information exchange. These communication mechanisms need a well-defined convention, i.e. a protocol. They also require flexibility in both the setup and changes to the protocol specification. The network compiler is a tool which provides the programmer with a means of establishing such a protocol for his application. Input to the network compiler is a single interface description file provided by the programmer. This file is written according to a grammar, and completely specifies the interprocess communication interfaces. Passed through the network compiler, the interface description file automatically produces the additional source code needed for the protocol. Hence the programmer does not have to be concerned about the details of the communication calls. Any further additions and modifications are made easy, because all the information about the interface is kept in a single file. (orig.)

  5. Development of a computer-aided diagnostic scheme for detection of interval changes in successive whole-body bone scans

    International Nuclear Information System (INIS)

    Shiraishi, Junji; Li Qiang; Appelbaum, Daniel; Pu Yonglin; Doi, Kunio

    2007-01-01

    Bone scintigraphy is the most frequent examination among various diagnostic nuclear medicine procedures. It is a well-established imaging modality for the diagnosis of osseous metastasis and for monitoring osseous tumor response to chemotherapy and radiation therapy. Although the sensitivity of bone scan examinations for detection of bone abnormalities has been considered to be relatively high, it is time consuming to identify multiple lesions such as bone metastases of prostate and breast cancers. In addition, it is very difficult to detect subtle interval changes between two successive abnormal bone scans, because of variations in patient conditions, the accumulation of radioisotopes during each examination, and the image quality of gamma cameras. Therefore, we developed a new computer-aided diagnostic (CAD) scheme for the detection of interval changes in successive whole-body bone scans by use of a temporal subtraction image which was obtained with a nonlinear image-warping technique. We carried out 58 pairs of successive bone scans in which each scan included both posterior and anterior views. We determined 107 'gold-standard' interval changes among the 58 pairs based on the consensus of three radiologists. Our computerized scheme consisted of seven steps, i.e., initial image density normalization on each image, image matching for the paired images, temporal subtraction by use of the nonlinear image-warping technique, initial detection of interval changes by use of temporal-subtraction images, image feature extraction of candidates of interval changes, rule-based tests by use of 16 image features for removing some false positives, and display of the computer output for identified interval changes. One hundred seven gold standard interval changes included 71 hot lesions (uptake was increased compared with the previous scan, or there was new uptake in the current scan) and 36 cold lesions (uptake was decreased or disappeared) for anterior and posterior views. The

  6. Computer-controlled radiation monitoring system

    International Nuclear Information System (INIS)

    Homann, S.G.

    1994-01-01

    A computer-controlled radiation monitoring system was designed and installed at the Lawrence Livermore National Laboratory's Multiuser Tandem Laboratory (10 MV tandem accelerator from High Voltage Engineering Corporation). The system continuously monitors the photon and neutron radiation environment associated with the facility and automatically suspends accelerator operation if preset radiation levels are exceeded. The system has proved reliable real-time radiation monitoring over the past five years, and has been a valuable tool for maintaining personnel exposure as low as reasonably achievable

  7. Multiaxis, Lightweight, Computer-Controlled Exercise System

    Science.gov (United States)

    Haynes, Leonard; Bachrach, Benjamin; Harvey, William

    2006-01-01

    The multipurpose, multiaxial, isokinetic dynamometer (MMID) is a computer-controlled system of exercise machinery that can serve as a means for quantitatively assessing a subject s muscle coordination, range of motion, strength, and overall physical condition with respect to a wide variety of forces, motions, and exercise regimens. The MMID is easily reconfigurable and compactly stowable and, in comparison with prior computer-controlled exercise systems, it weighs less, costs less, and offers more capabilities. Whereas a typical prior isokinetic exercise machine is limited to operation in only one plane, the MMID can operate along any path. In addition, the MMID is not limited to the isokinetic (constant-speed) mode of operation. The MMID provides for control and/or measurement of position, force, and/or speed of exertion in as many as six degrees of freedom simultaneously; hence, it can accommodate more complex, more nearly natural combinations of motions and, in so doing, offers greater capabilities for physical conditioning and evaluation. The MMID (see figure) includes as many as eight active modules, each of which can be anchored to a floor, wall, ceiling, or other fixed object. A cable is payed out from a reel in each module to a bar or other suitable object that is gripped and manipulated by the subject. The reel is driven by a DC brushless motor or other suitable electric motor via a gear reduction unit. The motor can be made to function as either a driver or an electromagnetic brake, depending on the required nature of the interaction with the subject. The module includes a force and a displacement sensor for real-time monitoring of the tension in and displacement of the cable, respectively. In response to commands from a control computer, the motor can be operated to generate a required tension in the cable, to displace the cable a required distance, or to reel the cable in or out at a required speed. The computer can be programmed, either locally or via

  8. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  9. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    OpenAIRE

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions wer...

  10. Impedance measurements on Au microelectrodes using controlled atmosphere high temperature scanning probe microscope

    DEFF Research Database (Denmark)

    Wu, Yuehua; Hansen, Karin Vels; Jacobsen, Torben

    2011-01-01

    High temperature impedance measurements on Au microelectrodes deposited on polished yttria stabilized zirconia (YSZ) pellets were demonstrated using a newly designed controlled atmosphere high temperature scanning probe microscope (CAHT-SPM). Probes based on Pt0.8Ir0.2 were fabricated and employed...

  11. Performance of the TRISTAN computer control network

    International Nuclear Information System (INIS)

    Koiso, H.; Abe, K.; Akiyama, A.; Katoh, T.; Kikutani, E.; Kurihara, N.; Kurokawa, S.; Oide, K.; Shinomoto, M.

    1985-01-01

    An N-to-N token ring network of twenty-four minicomputers controls the TRISTAN accelerator complex. The computers are linked by optical fiber cables with 10 Mbps transmission speed. The software system is based on the NODAL, a multi-computer interpreter language developed at CERN SPS. Typical messages exchanged between computers are NODAL programs and NODAL variables transmitted by the EXEC and the REMIT commands. These messages are exchanged as a cluster of packets whose maximum size is 512 bytes. At present, eleven minicomputers are connected to the network and the total length of the ring is 1.5 km. In this condition, the maximum attainable throughput is 980 kbytes/s. The response of a pair of an EXEC and a REMIT transactions which transmit a NODAL array A and one line of program 'REMIT A' and immediately remit the A is measured to be 95+0.039/chi/ ms, where /chi/ is the array size in byte. In ordinary accelerator operations, the maximum channel utilization is 2%, the average packet length is 96 bytes and the transmission rate is 10 kbytes/s

  12. Development of indigenous USB based ICT-controller for industrial computed tomography scanner

    International Nuclear Information System (INIS)

    Walinjkar, Parag; Umesh Kumar

    2014-01-01

    In Industrial Computed Tomography (ICT) the quality of tomographic image depends on the accuracy of data/measurement. Isotope Production and Applications Division (IP and AD) is pioneer in this field and equipped with advance facility of ICT using gamma rays as well as X-rays. ICT-controller has been developed indigenously, for parallel beam scanning technique, to control scanning and data acquisition process automatically as per user requirements. The process of scanning and data collection has been automated using commercially available USB module. The acquired raw data is then processed and tomographic image of the specimen reconstructed to test operational performance of the ICT-controller. The paper is about the development of ICT-controller. It also describes the tests carried out to confirm successful development of the ICT-controller. (author)

  13. Temporal evaluation of computed tomographic scans at a Level 1 trauma department in a central South African hospital

    Directory of Open Access Journals (Sweden)

    Tony Tiemesmann

    2016-03-01

    Objectives: The present study analyses the authors’ institution’s multi-detector computed tomography (MDCT scan process as part of the imaging turnaround time of trauma patients. It is intended to serve as a baseline for the institution, to offer a comparison with institutions worldwide and to improve service delivery. Method: Relevant categorical data were collected from the trauma patient register and radiological information system (RIS from 01 February 2013 to 31 January 2014. A population of 1107 trauma patients who received a MDCT scan was included in the study. Temporal data were analysed as a continuum with reference to triage priority, time of day, type of CT scan and admission status. Results: The median trauma arrival to MDCT scan time (TTS and reporting turnaround time (RTAT were 69 (39–126 and 86 (53–146 minutes respectively. TTS was subdivided into the time when the patient arrived at trauma to the radiology referral (TTRef and submission of the radiology request, to the arrival at the MDCT (RefTS location. TTRef was statistically significantly longer than RefTS (p < 0.0001. RTAT was subdivided into the arrival at the MDCT to the start of the radiology report (STR and time taken to complete the report (RT. STR was statistically significantly longer than RT (p < 0.0001. Conclusion: The time to scan (TTS was comparable to, but unfortunately the report turnaround time (RTAT lagged behind, the findings of some first-world institutions.

  14. Diagnostic efficacy and pitfalls of a 64-raw multislice computed tomography scan for mild head injuries in children

    International Nuclear Information System (INIS)

    Matsumoto, Yoshihisa; Nawashiro, Hiroshi; Uozumi, Youichi

    2010-01-01

    The aim of this study is to analyze the usefulness of 64-raw multislice computed tomography (CT) scans and bone images of three-dimensional CT (3D-CT) scans for evaluation of mild head injuries in children. Thirteen children (9 boys and 4 girls, less than or equal to 15 years old) with mild head injury were included in the study. Head CT scans obtained within 24 hours after injury. All children had no episodes of loss of consciousness, amnesia, epilepsy, vomiting, and no neurological abnormality on arrival at hospital. We detected 9 positive findings on CT scans, which looked like fracture lines at the frontal bone in 7 cases. The bone images of CT axial views revealed a true fracture in one case in which a skull X-ray could not demonstrate a fracture line, but, other positive findings turned out to be a diploic vein surrounded by a thin bone cortex. All false positive findings were detected in the patients under the age of 6. By the 3D-reconstructive CT scan, it is easier to detect not only the intracranial lesions but also the cranial fracture. But, the diploic vein is apt to be misdiagnosed as the fracture line, especially in patients under the age of 6. (author)

  15. Distributed computer controls for accelerator systems

    International Nuclear Information System (INIS)

    Moore, T.L.

    1988-09-01

    A distributed control system has been designed and installed at the Lawrence Livermore National Laboratory Multi-user Tandem Facility using an extremely modular approach in hardware and software. The two tiered, geographically organized design allowed total system implementation with four months with a computer and instrumentation cost of approximately $100K. Since the system structure is modular, application to a variety of facilities is possible. Such a system allows rethinking and operational style of the facilities, making possible highly reproducible and unattended operation. The impact of industry standards, i.e., UNIX, CAMAC, and IEEE-802.3, and the use of a graphics-oriented controls software suite allowed the efficient implementation of the system. The definition, design, implementation, operation and total system performance will be discussed. 3 refs

  16. Distributed computer controls for accelerator systems

    Science.gov (United States)

    Moore, T. L.

    1989-04-01

    A distributed control system has been designed and installed at the Lawrence Livermore National Laboratory Multiuser Tandem Facility using an extremely modular approach in hardware and software. The two tiered, geographically organized design allowed total system implantation within four months with a computer and instrumentation cost of approximately $100k. Since the system structure is modular, application to a variety of facilities is possible. Such a system allows rethinking of operational style of the facilities, making possible highly reproducible and unattended operation. The impact of industry standards, i.e., UNIX, CAMAC, and IEEE-802.3, and the use of a graphics-oriented controls software suite allowed the effective implementation of the system. The definition, design, implementation, operation and total system performance will be discussed.

  17. Distributed computer controls for accelerator systems

    International Nuclear Information System (INIS)

    Moore, T.L.

    1989-01-01

    A distributed control system has been designed and installed at the Lawrence Livermore National Laboratory Multiuser Tandem Facility using an extremely modular approach in hardware and software. The two tiered, geographically organized design allowed total system implantation within four months with a computer and instrumentation cost of approximately $100k. Since the system structure is modular, application to a variety of facilities is possible. Such a system allows rethinking of operational style of the facilities, making possible highly reproducible and unattended operation. The impact of industry standards, i.e., UNIX, CAMAC, and IEEE-802.3, and the use of a graphics-oriented controls software suite allowed the effective implementation of the system. The definition, design, implementation, operation and total system performance will be discussed. (orig.)

  18. Dose comparison of different scan projections of Implagraphy cone beam computed tomography for dental maxillofacial use

    International Nuclear Information System (INIS)

    Fang Dong; Yuan Xianshun; Zhang Dongsheng

    2012-01-01

    Objective: To evaluate the subject's absorbed dose,equivalent dose and effective dose. Methods: The CBCT unit was Implagraphy and three scan projections were selected such as mandible, maxilla and temporomandibular joint (TMJ). Thermoluminescent dosimeter tubes were used to record the absorbed dose at special positions in the head and neck region of an adult skull and tissue-equivalent phantom. 16 interested organs included pituitary, lens, parotid glands, submandibular glands, sublingual glands, diploe, spongy bone of the chin and cervical vertebra, skins of cheeks and nuchal region, thyroid and esophagus. The absorbed dose was measured in these organs, and then the effective dose (E 1990 , E 2007 ) were calculated according to different ICRP tissue weighting factors. Results: The absorbed dose of mandible,maxilla and TMJ scan varied from (0.99 ±0.09) to (12.85 ±0.09)mGy, (0.93 ±0.01) to (13.07 ±0.02) mGy and (0.68 ±0.01) to (10.18 ± 0.04)mGy. There was significant difference among the three scan projections (F=19.61-30992.27, P<0.05). The equivalent doses of lens and skin were (1.11± 0.07)-(5.76 ± 0.06) mSv and (6.96 ± 0.06)-(10.64 ± 0.07) mSv. There was significant difference among the three scan projections (F=4473.02, 9385.50, P<0.05). The effective dose (E 1990 , E 2007 ) was [(191.35±1.53), (325.17 ±2.58) μSv] for mandible scan, [(106.62 ±2.17), (226.28 ±2.81) μSv] for maxilla scan, [(104.21 ± 1.02), (142.36 ± 1.90) μSv]for TMJ scan, respectively. Conclusions: The valid measurement should be taken to reduce the subject's dose such as a careful history and clinical examination before the performance of CBCT, the latest risk/benefit assessment,precise scan position, the shielding of thyroid as well as brain and the smaller volume size as well. (authors)

  19. Advances in Future Computer and Control Systems v.1

    CERN Document Server

    Lin, Sally; 2012 International Conference on Future Computer and Control Systems(FCCS2012)

    2012-01-01

    FCCS2012 is an integrated conference concentrating its focus on Future Computer and Control Systems. “Advances in Future Computer and Control Systems” presents the proceedings of the 2012 International Conference on Future Computer and Control Systems(FCCS2012) held April 21-22,2012, in Changsha, China including recent research results on Future Computer and Control Systems of researchers from all around the world.

  20. Advances in Future Computer and Control Systems v.2

    CERN Document Server

    Lin, Sally; 2012 International Conference on Future Computer and Control Systems(FCCS2012)

    2012-01-01

    FCCS2012 is an integrated conference concentrating its focus on Future Computer and Control Systems. “Advances in Future Computer and Control Systems” presents the proceedings of the 2012 International Conference on Future Computer and Control Systems(FCCS2012) held April 21-22,2012, in Changsha, China including recent research results on Future Computer and Control Systems of researchers from all around the world.

  1. Surgical outcome prediction in patients with advanced ovarian cancer using computed tomography scans and intraoperative findings

    Directory of Open Access Journals (Sweden)

    Ha-Jeong Kim

    2014-09-01

    Conclusion: The combination of omental extension to the stomach or spleen and involvement of inguinal or pelvic lymph nodes in preoperative CT scans is considered predictive of suboptimal cytoreduction. These patients may be more appropriately treated with neoadjuvant chemotherapy followed by surgical cytoreduction.

  2. Computed tomography scan in supine and prone positions: an alternative method to detect intramural gas in emphysematous cystitis and to evaluate efficacy after adjuvant continuous intravesical irrigation treatment.

    Science.gov (United States)

    Cortés-González, Jeff R; Ortiz-Lara, Gerardo E; Salinas, Matías; Hernández-Galván, Fernando; Gómez-Guerra, Lauro S

    2013-04-01

    To evaluate the efficacy of continuous intravesical irrigation with saline plus amikacin as adjuvant therapy and to evaluate the computed tomography (CT) scan in supine and prone positions (CystoCT scan) as an alternative diagnostic and evaluation method of intramural gas in emphysematous cystitis (EC) before and after treatment. Consecutive patients with a diagnosis of EC who were hospitalized between March 2006 and January 2011 were investigated. The diagnosis was made by CystoCT scan. Treatment consisted of intravenous antibiotics, control of concomitant diseases, and placement of a 3-way urinary catheter for continuous irrigation of 500 mg of amikacin diluted in 1 l of saline given on days 0, 3, and 7. Treatment was considered successful when there was an absence of gas in the bladder wall, the urine culture was negative, there was clinical improvement, and there was an absence of toxicity. Eleven patients were hospitalized with a diagnosis of EC during the study period. Four were excluded from the study, 2 due to the lack of confirmation of the diagnosis with the CystoCT scan. Treatment was successful in all patients; for 6 (86%) this was achieved in 3 days and for 1 (14%) in 7 days. No toxicity was reported. Continuous intravesical irrigation with saline plus amikacin as adjuvant treatment of EC is an inexpensive, effective, and safe tool that might help conventional treatment and provide a rapid recovery. The CystoCT scan is an alternative method to diagnose and evaluate intramural gas in EC patients. These findings should be challenged in a randomized, multi-centre, placebo-controlled clinical trial.

  3. Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)

    International Nuclear Information System (INIS)

    Sabour, Siamak; Rutten, A.; Schouw, Y. T. van der; Atsma, F.; Grobbee, D. E.; Mali, W. P.; Bartelink, M. E. L.; Bots, M. L.; Prokop, M.

    2007-01-01

    Purpose. To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables.Design. Cross-sectional study with repeated measurements. Materials and methods. The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC).Results. Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements.Conclusion. Inter-scan reproducibility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter

  4. Magnetic-field-controlled negative differential conductance in scanning tunneling spectroscopy of graphene npn junction resonators

    Science.gov (United States)

    Li, Si-Yu; Liu, Haiwen; Qiao, Jia-Bin; Jiang, Hua; He, Lin

    2018-03-01

    Negative differential conductance (NDC), characterized by the decreasing current with increasing voltage, has attracted continuous attention for its various novel applications. The NDC typically exists in a certain range of bias voltages for a selected system and controlling the regions of NDC in curves of current versus voltage (I -V ) is experimentally challenging. Here, we demonstrate a magnetic-field-controlled NDC in scanning tunneling spectroscopy of graphene npn junction resonators. The magnetic field not only can switch on and off the NDC, but also can continuously tune the regions of the NDC in the I -V curves. In the graphene npn junction resonators, magnetic fields generate sharp and pronounced Landau-level peaks with the help of the Klein tunneling of massless Dirac fermions. A tip of scanning tunneling microscope induces a relatively shift of the Landau levels in graphene beneath the tip. Tunneling between the misaligned Landau levels results in the magnetic-field-controlled NDC.

  5. Evaluation of automatic exposure control systems in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Reina, Thamiris Rosado

    2014-07-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  6. Evaluation of automatic exposure control systems in computed tomography

    International Nuclear Information System (INIS)

    Reina, Thamiris Rosado

    2014-01-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  7. Computed Tomography Scanning to Understand Micro-to-Macro Controls on Multiphase Flow during Geologic Carbon Storage; NETL-TRS-3-2017; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2017; p 24.

    Energy Technology Data Exchange (ETDEWEB)

    Crandall, Dustin M. [National Energy Technology Lab. (NETL), Morgantown, WV (United States); Moore, Johnathan E. [National Energy Technology Lab. (NETL) and AECOM, Morgantown, WV (United States); Tudek, John K. [National Energy Technology Lab. (NETL) and AECOM, Morgantown, WV (United States); Gill, Magdalena K [National Energy Technology Lab. (NETL) and ORISE, Morgantown, WV (United States)

    2017-03-01

    Evaluation of the fate and transport of carbon dioxide (CO2) in deep reservoirs is crucial to the development of long-term geologic carbon sequestration (GCS) technologies. In this report, various studies using computed tomography (CT) scanning are utilized in conjunction with traditional flow tests to observe the multi-scale phenomena associated with CO2 injection in geologic media. Pore scale analyses were performed to determine the infiltration characteristics of CO2 into a brine saturated reservoir rock. Multiphase floods were performed to evaluate the saturation of CO2 into a brine-saturated reservoir rock and determine how structural changes within the lithology affect such interactions. Additionally, CO2 induced swelling of unconventional reservoir rock was evaluated with respect to reductions in fracture transmissivity due to matrix swelling. These studies are just a few examples of the benefits of multi-scale CT imaging in conjunction with traditional laboratory methodology to gain a better understanding of the interactions between CO2 and the lithologies it interacts with during GCS.

  8. Computer utility for interactive instrument control

    International Nuclear Information System (INIS)

    Day, P.

    1975-08-01

    A careful study of the ANL laboratory automation needs in 1967 led to the conclusion that a central computer could support all of the real-time needs of a diverse collection of research instruments. A suitable hardware configuration would require an operating system to provide effective protection, fast real-time response and efficient data transfer. An SDS Sigma 5 satisfied all hardware criteria, however it was necessary to write an original operating system; services include program generation, experiment control real-time analysis, interactive graphics and final analysis. The system is providing real-time support for 21 concurrently running experiments, including an automated neutron diffractometer, a pulsed NMR spectrometer and multi-particle detection systems. It guarantees the protection of each user's interests and dynamically assigns core memory, disk space and 9-track magnetic tape usage. Multiplexor hardware capability allows the transfer of data between a user's device and assigned core area at rates of 100,000 bytes/sec. Real-time histogram generation for a user can proceed at rates of 50,000 points/sec. The facility has been self-running (no computer operator) for five years with a mean time between failures of 10 []ays and an uptime of 157 hours/week. (auth)

  9. Computer-controlled wall servicing robot

    Energy Technology Data Exchange (ETDEWEB)

    Lefkowitz, S. [Pentek, Inc., Corapolis, PA (United States)

    1995-03-01

    After four years of cooperative research, Pentek has unveiled a new robot with the capability to automatically deliver a variety of cleaning, painting, inspection, and surveillance devices to large vertical surfaces. The completely computer-controlled robot can position a working tool on a 50-foot tall by 50-foot wide vertical surface with a repeatability of 1/16 inch. The working end can literally {open_quotes}fly{close_quotes} across the face of a wall at speed of 60 per minute, and can handle working loads of 350 pounds. The robot was originally developed to decontaminate the walls of reactor fueling cavities at commercial nuclear power plants during fuel outages. If these cavities are left to dry after reactor refueling, contamination present in the residue could later become airborne and move throughout the containment building. Decontaminating the cavity during the refueling outage reduces the need for restrictive personal protective equipment during plant operations to limit the dose rates.

  10. A LabVIEWTM-based scanning and control system for proton beam micromachining

    International Nuclear Information System (INIS)

    Bettiol, Andrew A.; Kan, J.A. van; Sum, T.C.; Watt, F.

    2001-01-01

    LabVIEW TM is steadily gaining in popularity as the programming language of choice for scientific data acquisition and control. This is due to the vast array of measurement instruments and data acquisition cards supported by the LabVIEW TM environment, and the relative ease with which advanced software can be programmed. Furthermore, virtual instruments that are designed for a given system can be easily ported to other LabVIEW TM platforms and hardware. This paper describes the new LabVIEW TM based scanning and control system developed specifically for proton beam micromachining (PBM) applications. The new system is capable of scanning figures at 16-bit resolution with improved sub-microsecond scan rates. Support for electrostatic beam blanking and external dose normalization using a TTL signal have been implemented. The new software incorporates a semi-automated dose calibration system, and a number of novel dose normalization methods. Limitations of the current beam scanning hardware are discussed in light of new results obtained from micromachining experiments performed in SU-8 photoresist

  11. Reversible bronchial dilatation in children: comparison of serial high-resolution computer tomography scans of the lungs

    Energy Technology Data Exchange (ETDEWEB)

    Gaillard, E.A. E-mail: erol.gaillard@lwh-tr.nwest.nhs.uk; Carty, H.; Heaf, D.; Smyth, R.L

    2003-09-01

    Introduction: bronchiectasis is generally considered irreversible in the adult population, largely based on studies employing bronchography in cases with a significant clinical history. It is assumed, that the same is true for children. Few studies have examined the natural history of bronchiectasis in children and diagnostic criteria on high-resolution computer tomography of the lungs are derived from studies on adults. Frequently, bronchiectasis is reported in children in cases where localised bronchial dilatation is present, incorrectly labelling these children with an irreversible life-long condition. Objective: to evaluate changes in appearance of bronchial dilatation, unrelated to cystic fibrosis in children, as assessed by sequential high-resolution computer tomography (HRCT) of the lungs. Methods: the scans of 22 children with a radiological diagnosis of bronchiectasis, seen at Alder Hey Children's Hospital between 1994 and 2000, who had at least two CT scans of the lungs were reviewed by a single radiologist, who was blinded to the original report. Results: following a median scan interval of 21 months (range 2-43), bronchial dilatation resolved completely in six children and there was improvement in appearances in a further eight, with medical treatment alone. Discussion: a radiological diagnosis of bronchiectasis should be considered with caution in children as diagnostic criteria derived from studies in adults have not been validated in children and the condition is generally considered irreversible.

  12. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions.

    Science.gov (United States)

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-05-01

    To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

  13. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    Science.gov (United States)

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken. PMID:27226958

  14. Registration area and accuracy when integrating laser-scanned and maxillofacial cone-beam computed tomography images.

    Science.gov (United States)

    Sun, LiJun; Hwang, Hyeon-Shik; Lee, Kyung-Min

    2018-03-01

    The purpose of this study was to examine changes in registration accuracy after including occlusal surface and incisal edge areas in addition to the buccal surface when integrating laser-scanned and maxillofacial cone-beam computed tomography (CBCT) dental images. CBCT scans and maxillary dental casts were obtained from 30 patients. Three methods were used to integrate the images: R1, only the buccal and labial surfaces were used; R2, the incisal edges of the anterior teeth and the buccal and distal marginal ridges of the second molars were used; and R3, labial surfaces, including incisal edges of anterior teeth, and buccal surfaces, including buccal and distal marginal ridges of the second molars, were used. Differences between the 2 images were evaluated by color-mapping methods and average surface distances by measuring the 3-dimensional Euclidean distances between the surface points on the 2 images. The R1 method showed more discrepancies between the laser-scanned and CBCT images than did the other methods. The R2 method did not show a significant difference in registration accuracy compared with the R3 method. The results of this study indicate that accuracy when integrating laser-scanned dental images into maxillofacial CBCT images can be increased by including occlusal surface and incisal edge areas as registration areas. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  15. Transient gyriform brightness on non-contrast enhanced computed tomography (CT) brain scan of seven infants

    International Nuclear Information System (INIS)

    Close, P.J.; Carty, H.M.

    1991-01-01

    Spontaneous gyriform brightness seen on CT scan is an unusual finding unless associated with arteriovenous malformations (AVM). There are sporadic case reports in the literature of its occurrence in association with herpex simplex virus encephalitis (HSVE), purulent meningitis, following chemotherapy for leukaemia, in a child with chronic renal failure, and in a child with folic acid deficiency. We present a series of seven cases exhibiting this phenomenon, none of whom have AVMs, who have been scanned at this hospital in the first 2 1/2 years following the installation of a CT scanner. Four of the cases had congenital heart disease requiring corrective surgery or cardiac catheterisation. The other three had probable meningo-encephalitis. In all cases the gyriform brightness followed an ischaemic insult to the child's brain. We hypothesise that this phenomenon is an ischaemic response in the immature brain and that its occurrence is not so rare as the literature may suggest. (orig.)

  16. Computer Tool for Automatically Generated 3D Illustration in Real Time from Archaeological Scanned Pieces

    OpenAIRE

    Luis López; Germán Arroyo; Domingo Martín

    2012-01-01

    The graphical documentation process of archaeological pieces requires the active involvement of a professional artist to recreate beautiful illustrations using a wide variety of expressive techniques. Frequently, the artist’s work is limited by the inconvenience of working only with the photographs of the pieces he is going to illustrate. This paper presents a software tool that allows the easy generation of illustrations in real time from 3D scanned models. The developed interface allows the...

  17. Ultrasound detection of pneumothorax compared with chest X-ray and computed tomography scan.

    Science.gov (United States)

    Nagarsheth, Khanjan; Kurek, Stanley

    2011-04-01

    Pneumothorax after trauma can be a life threatening injury and its care requires expeditious and accurate diagnosis and possible intervention. We performed a prospective, single blinded study with convenience sampling at a Level I trauma center comparing thoracic ultrasound with chest X-ray and CT scan in the detection of traumatic pneumothorax. Trauma patients that received a thoracic ultrasound, chest X-ray, and chest CT scan were included in the study. The chest X-rays were read by a radiologist who was blinded to the thoracic ultrasound results. Then both were compared with CT scan results. One hundred and twenty-five patients had a thoracic ultrasound performed in the 24-month period. Forty-six patients were excluded from the study due to lack of either a chest X-ray or chest CT scan. Of the remaining 79 patients there were 22 positive pneumothorax found by CT and of those 18 (82%) were found on ultrasound and 7 (32%) were found on chest X-ray. The sensitivity of thoracic ultrasound was found to be 81.8 per cent and the specificity was found to be 100 per cent. The sensitivity of chest X-ray was found to be 31.8 per cent and again the specificity was found to be 100 per cent. The negative predictive value of thoracic ultrasound for pneumothorax was 0.934 and the negative predictive value for chest X-ray for pneumothorax was found to be 0.792. We advocate the use of chest ultrasound for detection of pneumothorax in trauma patients.

  18. Scanning tunnelling microscope fabrication of phosphorus array in silicon for a nuclear spin quantum computer

    International Nuclear Information System (INIS)

    O'Brien, J.L.; Schofield, S.R.; Simmons, M.Y.; Clark, R.G.; Dzurak, A.S.; Prawer, S.; Adrienko, I.; Cimino, A.

    2000-01-01

    Full text: In the vigorous worldwide effort to experimentally build a quantum computer, recent intense interest has focussed on solid state approaches for their promise of scalability. Particular attention has been given to silicon-based proposals that can readily be integrated into conventional computing technology. For example the Kane design uses the well isolated nuclear spin of phosphorous donor nuclei (I=1/2) as the qubits embedded in isotopically pure 28 Si (I=0). We demonstrate the ability to fabricate a precise array of P atoms on a clean Si surface with atomic-scale resolution compatible with the fabrication of the Kane quantum computer

  19. System for connection of a scanning measuring equipment with a computer

    International Nuclear Information System (INIS)

    Avdeev, N.F.; Bogomolov, M.N.; Volkov, G.A.

    1976-01-01

    A system of communication of viewing and measuring devices is considered ensuring an on-line operation with BESM-4 computer. A program of film data processing is presented. A detailed description is given with respect to an interface. Modifications are mentioned in some units of the semi-automatic devices which ensure a communication with a computer. The communication system allows for a man-machine dialogue

  20. A scanning point source for quality control of FOV uniformity in GC-PET imaging

    International Nuclear Information System (INIS)

    Bergmann, H.; Minear, G.; Dobrozemsky, G.; Nowotny, R.; Koenig, B.

    2002-01-01

    Aim: PET imaging with coincidence cameras (GC-PET) requires additional quality control procedures to check the function of coincidence circuitry and detector zoning. In particular, the uniformity response over the field of view needs special attention since it is known that coincidence counting mode may suffer from non-uniformity effects not present in single photon mode. Materials and methods: An inexpensive linear scanner with a stepper motor and a digital interface to a PC with software allowing versatile scanning modes was developed. The scanner is used with a source holder containing a Sodium-22 point source. While moving the source along the axis of rotation of the GC-PET system, a tomographic acquisition takes place. The scan covers the full axial field of view of the 2-D or 3-D scatter frame. Depending on the acquisition software, point source scanning takes place continuously while only one projection is acquired or is done in step-and-shoot mode with the number of positions equal to the number of gantry steps. Special software was developed to analyse the resulting list mode acquisition files and to produce an image of the recorded coincidence events of each head. Results: Uniformity images of coincidence events were obtained after further correction for systematic sensitivity variations caused by acquisition geometry. The resulting images are analysed visually and by calculating NEMA uniformity indices as for a planar flood field. The method has been applied successfully to two different brands of GC-PET capable gamma cameras. Conclusion: Uniformity of GC-PET can be tested quickly and accurately with a routine QC procedure, using a Sodium-22 scanning point source and an inexpensive mechanical scanning device. The method can be used for both 2-D and 3-D acquisition modes and fills an important gap in the quality control system for GC-PET

  1. When the non-contrast-enhanced phase is unnecessary in abdominal computed tomography scans? A retrospective analysis of 244 cases

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Danilo Manuel Cerqueira; Salvadori, Priscila Silveira; Monjardim, Rodrigo da Fonseca; Bretas, Elisa Almeida Sathler; Torres, Lucas Rios; Caldana, Rogerio Pedreschi; Shigueoka, David Carlos; Medeiros, Regina Bitelli; D' ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2013-06-15

    Objective: to evaluate the necessity of the non contrast-enhanced phase in abdominal computed tomography scans. Materials and Methods: A retrospective, cross-sectional, observational study was developed, evaluating 244 consecutive abdominal computed tomography scans both with and without contrast injection. Initially, the contrast-enhanced images were analyzed (first analysis). Subsequently, the observers had access to the non-contrast-enhanced images for a second analysis. The primary and secondary diagnoses were established as a function of the clinical indications for each study (such as tumor staging, acute abdomen, investigation for abdominal collection and hepatocellular carcinoma, among others). Finally, the changes in the diagnoses resulting from the addition of the non-contrast-enhanced phase were evaluated. Results: Only one (0.4%; p > 0.999; non-statistically significant) out of the 244 reviewed cases had the diagnosis changed after the reading of non-contrast-enhanced images. As the secondary diagnoses are considered, 35 (14%) cases presented changes after the second analysis, as follows: nephrolithiasis (10%), steatosis (3%), adrenal nodule (0.7%) and cholelithiasis (0.3%). Conclusion: For the clinical indications of tumor staging, acute abdomen, investigation of abdominal collections and hepatocellular carcinoma, the non-contrast-enhanced phase can be excluded from abdominal computed tomography studies with no significant impact on the diagnosis. (author)

  2. Computer-based control systems of nuclear power plants

    International Nuclear Information System (INIS)

    Kalashnikov, V.K.; Shugam, R.A.; Ol'shevsky, Yu.N.

    1975-01-01

    Computer-based control systems of nuclear power plants may be classified into those using computers for data acquisition only, those using computers for data acquisition and data processing, and those using computers for process control. In the present paper a brief review is given of the functions the systems above mentioned perform, their applications in different nuclear power plants, and some of their characteristics. The trend towards hierarchic systems using control computers with reserves already becomes clear when consideration is made of the control systems applied in the Canadian nuclear power plants that pertain to the first ones equipped with process computers. The control system being now under development for the large Soviet reactors of WWER type will also be based on the use of control computers. That part of the system concerned with controlling the reactor assembly is described in detail

  3. Controlling data transfers from an origin compute node to a target compute node

    Science.gov (United States)

    Archer, Charles J [Rochester, MN; Blocksome, Michael A [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian E [Rochester, MN

    2011-06-21

    Methods, apparatus, and products are disclosed for controlling data transfers from an origin compute node to a target compute node that include: receiving, by an application messaging module on the target compute node, an indication of a data transfer from an origin compute node to the target compute node; and administering, by the application messaging module on the target compute node, the data transfer using one or more messaging primitives of a system messaging module in dependence upon the indication.

  4. Dosimetry in Computed Tomography head and neck scans; Dosimetria em varreduras de Tomografia Computadorizada de cabeça e pescoço

    Energy Technology Data Exchange (ETDEWEB)

    Gómez, A.M.L.; Santana, P.C.; Mourão, A.P., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais (UFMG), Berlo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Non-invasive diagnostic methods for X-rays, such as computed tomography (CT), have shown rapid growth in radiology services. There is concern about the radiation doses deposited in patients because the CT scans are the ones that contribute most to the dose increase in the population. The legislation for regulating patient dose levels only imposes an upper limit for a given test, depending on the region of the body to be irradiated. Therefore, it is necessary to know the dose values deposited in patients referring to routine protocols used in radiology services and propose an optimization of these according to the principles of radiological protection. Experiments were performed to determine the dose profile deposited in routine adult patient head scans using a male anthropomorphic simulator. Radiochromic film strips were introduced in the central region of the simulator to record the dose profile in the head and neck region and thus determine the air kerma values within the simulator object. Four scans were performed on a General Electric 64-channel tomograph programmed in helical mode and the scans were made with voltages of 80, 100 and 120 kV, and fixed current and automatic current control were used. The mean values recorded on the strips ranged from 14.82 to 22.98 mGy. Imaging noise analyzes were performed so that for all the scans the images obtained were considered of diagnostic quality and the Kerma values in the air when converted to absorbed dose are diagnostic parameters acceptable in the Brazilian legislation.

  5. Please Don't Move-Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features.

    Science.gov (United States)

    Rantalainen, Timo; Chivers, Paola; Beck, Belinda R; Robertson, Sam; Hart, Nicolas H; Nimphius, Sophia; Weeks, Benjamin K; McIntyre, Fleur; Hands, Beth; Siafarikas, Aris

    Most imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans. However, previously reported objective methods either cannot be applied on the reconstructed image or have not been tested for distal bone sites. Therefore, the purpose of the present study was to develop and validate motion artifact classifiers to quantify motion artifact in pQCT scans. Whether textural features could provide adequate motion artifact classification performance in 2 adolescent datasets with pQCT scans from tibial and radial diaphyses and epiphyses was tested. The first dataset was split into training (66% of sample) and validation (33% of sample) datasets. Visual classification was used as the ground truth. Moderate to substantial classification performance (J48 classifier, kappa coefficients from 0.57 to 0.80) was observed in the validation dataset with the novel texture-based classifier. In applying the same classifier to the second cross-sectional dataset, a slight-to-fair (κ = 0.01-0.39) classification performance was observed. Overall, this novel textural analysis-based classifier provided a moderate-to-substantial classification of motion artifact when the classifier was specifically trained for the measurement device and population. Classification based on textural features may be used to prescreen obviously acceptable and unacceptable scans, with a subsequent human-operated visual classification of any remaining scans. Copyright © 2017 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  6. Dialogue scanning measuring systems

    International Nuclear Information System (INIS)

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software

  7. Posterior Urethra Rupture: Contrast-Enhanced Computed Tomography Scan and Urethrocystography Demonstrations

    Directory of Open Access Journals (Sweden)

    Wojciech Marks

    2012-01-01

    Full Text Available In the follow-up study of patients with pelvic fractures, rupture of the posterior urethra is registered in 3–25% of cases (Koraitim et al., 1996. The diagnostic gold standard for the assessment of hemodynamically stable trauma patients is contrast-enhanced CT scan, especially helical CT. Nevertheless, simultaneous suprapubic cystography and ascending urethrograms (the so-called up-and-downogram are the investigation of choice in assessing the site, severity, and length of urethral injuries. (Carlin and Resnick, 1995 This paper discusses the evaluation and diagnosis of urethral injury in multiple-trauma patient.

  8. Computer controlled vacuum control system for synchrotron radiation beam lines

    International Nuclear Information System (INIS)

    Goldberg, S.M.; Wang, C.; Yang, J.

    1983-01-01

    The increasing number and complexity of vacuum control systems at the Stanford Synchrotron Radiation Laboratory has resulted in the need to computerize its operations in order to lower costs and increase efficiency of operation. Status signals are transmitted through digital and analog serial data links which use microprocessors to monitor vacuum status continuously. Each microprocessor has a unique address and up to 256 can be connected to the host computer over a single RS232 data line. A FORTRAN program on the host computer will request status messages and send control messages via only one RS232 line per beam line, signal the operator when a fault condition occurs, take automatic corrective actions, warn of impending valve failure, and keep a running log of all changes in vacuum status for later recall. Wiring costs are thus greatly reduced and more status conditions can be monitored without adding excessively to the complexity of the system. Operators can then obtain status reports at various locations in the lab quickly without having to read a large number of meter and LED's

  9. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

    Science.gov (United States)

    Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico

    2017-04-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.

  10. Computer-aided diagnosis of pneumoconiosis abnormalities extracted from chest radiographs scanned with a CCD scanner

    International Nuclear Information System (INIS)

    Abe, Koji; Minami, Masahide; Nakamura, Munehiro

    2011-01-01

    This paper presents a computer-aided diagnosis for pneumoconiosis radiographs obtained with a common charge-coupled devices (CCD) scanner. Since the current computer-aided diagnosis systems of pneumoconiosis are not practical for medical doctors due to high costs of usage for a special scanner, we propose a novel system which measures abnormalities of pneumoconiosis from lung images obtained with a common CCD scanner. Experimental results of discriminations between normal and abnormal cases for 56 right-lung images including 6 standard pneumoconiosis images have shown that the proposed abnormalities are well extracted according to the standards of pneumoconiosis categories. (author)

  11. Assessing the Accuracy of High Resolution Digital Surface Models Computed by PhotoScan® and MicMac® in Sub-Optimal Survey Conditions

    Directory of Open Access Journals (Sweden)

    Marion Jaud

    2016-06-01

    Full Text Available For monitoring purposes and in the context of geomorphological research, Unmanned Aerial Vehicles (UAV appear to be a promising solution to provide multi-temporal Digital Surface Models (DSMs and orthophotographs. There are a variety of photogrammetric software tools available for UAV-based data. The objective of this study is to investigate the level of accuracy that can be achieved using two of these software tools: Agisoft PhotoScan® Pro and an open-source alternative, IGN© MicMac®, in sub-optimal survey conditions (rugged terrain, with a large variety of morphological features covering a range of roughness sizes, poor GPS reception. A set of UAV images has been taken by a hexacopter drone above the Rivière des Remparts, a river on Reunion Island. This site was chosen for its challenging survey conditions: the topography of the study area (i involved constraints on the flight plan; (ii implied errors on some GPS measurements; (iii prevented an optimal distribution of the Ground Control Points (GCPs and; (iv was very complex to reconstruct. Several image processing tests are performed with different scenarios in order to analyze the sensitivity of each software package to different parameters (image quality, numbers of GCPs, etc.. When computing the horizontal and vertical errors within a control region on a set of ground reference targets, both methods provide rather similar results. A precision up to 3–4 cm is achievable with these software packages. The DSM quality is also assessed over the entire study area comparing PhotoScan DSM and MicMac DSM with a Terrestrial Laser Scanner (TLS point cloud. PhotoScan and MicMac DSM are also compared at the scale of particular features. Both software packages provide satisfying results: PhotoScan is more straightforward to use but its source code is not open; MicMac is recommended for experimented users as it is more flexible.

  12. Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans

    NARCIS (Netherlands)

    Al-Rawi, B.; Hassan, B.; Vandenberge, B.; Jacobs, R.

    2010-01-01

    The use of three-dimensional (3D) models of the dentition obtained from cone beam computed tomography (CBCT) is becoming increasingly more popular in dentistry. A recent trend is to replace the traditional dental casts with digital CBCT models for diagnosis, treatment planning and simulation. The

  13. Detection of defects in logs using computer assisted tomography (CAT) scanning

    International Nuclear Information System (INIS)

    Tonner, P.D.; Lupton, L.R.

    1985-01-01

    The Chalk River Nuclear Laboratories of AECL have performed a preliminary feasibility study on the applicability of computer assisted tomographic techniques to detect the internal structure of logs. Cross sections of three logs have been obtained using a medical CAT scanner. The results show that knots, rot and growth rings are easily recognized in both dry and wet logs

  14. Incidental findings on cone beam computed tomography scans in cleft lip and palate patients

    NARCIS (Netherlands)

    Kuijpers, Mette A. R.; Pazera, Andrzej; Admiraal, Ronald J.; Berge, Stefaan J.; Vissink, Arjan; Pazera, Pawel

    Cone beam computed tomography (CBCT) is frequently used in treatment planning for alveolar bone grafting (ABG) and orthognathic surgery in patients with cleft lip and palate (CLP). CBCT images may depict coincident findings. The aim of this study was to assess the prevalence of incidental findings

  15. Incidental findings on cone beam computed tomography scans in cleft lip and palate patients

    NARCIS (Netherlands)

    Kuijpers, M.A.R.; Pazera, A.; Admiraal, R.J.C.; Berge, S.J.; Vissink, A.; Pazera, P.

    2014-01-01

    OBJECTIVES: Cone beam computed tomography (CBCT) is frequently used in treatment planning for alveolar bone grafting (ABG) and orthognathic surgery in patients with cleft lip and palate (CLP). CBCT images may depict coincident findings. The aim of this study was to assess the prevalence of

  16. Robotic Automation in Computer Controlled Polishing

    Science.gov (United States)

    Walker, D. D.; Yu, G.; Bibby, M.; Dunn, C.; Li, H.; Wu, Y.; Zheng, X.; Zhang, P.

    2016-02-01

    We first present a Case Study - the manufacture of 1.4 m prototype mirror-segments for the European Extremely Large Telescope, undertaken by the National Facility for Ultra Precision Surfaces, at the OpTIC facility operated by Glyndwr University. Scale-up to serial-manufacture demands delivery of a 1.4 m off-axis aspheric hexagonal segment with surface precision robots and computer numerically controlled ('CNC') polishing machines for optical fabrication. The objective was not to assess which is superior. Rather, it was to understand for the first time their complementary properties, leading us to operate them together as a unit, integrated in hardware and software. Three key areas are reported. First is the novel use of robots to automate currently-manual operations on CNC polishing machines, to improve work-throughput, mitigate risk of damage to parts, and reduce dependence on highly-skilled staff. Second is the use of robots to pre-process surfaces prior to CNC polishing, to reduce total process time. The third draws the threads together, describing our vision of the automated manufacturing cell, where the operator interacts at cell rather than machine level. This promises to deliver a step-change in end-to-end manufacturing times and costs, compared with either platform used on its own or, indeed, the state-of-the-art used elsewhere.

  17. Serial cranial computed-tomography scans in children with leukemia given two different forms of central nervous system therapy

    International Nuclear Information System (INIS)

    Ochs, J.J.; Parvey, L.S.; Whitaker, J.N.; Bowman, W.P.; Ch'ien, L.; Campbell, M.; Coburn, T.

    1983-01-01

    Cranial computed tomography (CT) was used to estimate the frequency and permanence of brain abnormalities in 108 consecutive children with acute lymphoblastic leukemia (ALL). Fifty-five patients received cranial irradiation (1,800 rad) with intrathecal methotrexate (RT group) and 53 patients received intravenous and intrathecal methotrexate without irradiation (IVIT group). Continuation treatment included sequential drug pairs for the RT group and periodic IVIT methotrexate for the other group. After 12 to 24 months of serial evaluation, five (9%) of the 55 patients in the RT group have had CT scan abnormalities, compared to 10 (19%) of 52 in the IVIT group (p . 0.171). Fourteen of the 15 patients with CT scan abnormalities had focal or diffuse white-matter hypodensity; these have reverted to normal in most cases, reflecting a dynamic process. While such CT findings are of concern and may be an early indicator of central nervous system toxicity, this remains to be proven. Therapy should not be altered on the basis of abnormal CT scans alone but in the context of the entire clinical situation

  18. Evaluating the periapical status of teeth with irreversible pulpitis by using cone-beam computed tomography scanning and periapical radiographs.

    Science.gov (United States)

    Abella, Francesc; Patel, Shanon; Duran-Sindreu, Fernando; Mercadé, Montse; Bueno, Rufino; Roig, Miguel

    2012-12-01

    The purpose of this study was to compare the prevalence of apical periodontitis (AP) on individual roots of teeth with irreversible pulpitis viewed with periapical (PA) radiographs and cone-beam computed tomography (CBCT) scans. PA radiographs and CBCT scans were taken of 138 teeth in 130 patients diagnosed with irreversible pulpitis (symptomatic and asymptomatic). Two calibrated examiners assessed the presence or absence of AP lesions by analyzing the PA and CBCT images. A consensus was reached in the event of any disagreement. The data were analyzed using the hypothesis test, and significance was set at P ≤ .05. Three hundred seven paired roots were assessed with both PA and CBCT images. A comparison of the 307 paired roots revealed that AP lesions were present in 10 (3.3%) and absent in 297 (96.7%) pairs of roots when assessed with PA radiography. When the same 307 sets of roots were assessed with CBCT scans, AP lesions were present in 42 (13.7%) and absent in 265 (86.3%) paired roots. The prevalence of AP lesions detected with CBCT was significantly higher in the symptomatic group compared with the asymptomatic group (P < .05). An additional 22 roots were identified with CBCT alone. The present study highlights the advantages of using CBCT for detecting AP lesions, especially in teeth with symptomatic irreversible pulpitis. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Sudden headache, lumbar puncture, and the diagnosis of subarachnoid hemorrhage in patients with a normal computed tomography scans.

    Science.gov (United States)

    Valle Alonso, Joaquín; Fonseca Del Pozo, Francisco Javier; Vaquero Álvarez, Manuel; De la Fuente Carillo, Juan José; Llamas, José Carlos; Hernández Montes, Yelda

    2018-02-01

    To assess the usefulness of computed tomography (CT) to identify subarachnoid bleeding in patients with neurologic deficits seeking emergency care for sudden headache within 6 hours of onset of symptoms. Retrospective observational study of patients presenting with sudden nontraumatic headache peaking during the previous hour in the absence of neurologic deficits. We ordered CT scans for all patients, and if the scan was normal we performed a lumbar puncture. All patients were then followed for 6 months. Eighty-five patients were included. Subarachnoid bleeding was identified in 10 (10.2%) patients by CT. Seventy- four lumbar punctures were performed in patients with negative CTs; the lumbar puncture was positive in 1 patient and inconclusive in 2 patients. In all 3 patients, bleeding was ruled out with later images; thus, no cases of subarachnoid hemorrhage were confirmed in the 74 patients who underwent lumbar puncture. Nor were any cases found in any of these patients during follow-up. A CT scan taken within 6 hours of onset of sudden headache is sufficient for confirming or ruling out subarachnoid bleeding in patients with sudden headache who have no neurologic deficits.

  20. Computer Tool for Automatically Generated 3D Illustration in Real Time from Archaeological Scanned Pieces

    Directory of Open Access Journals (Sweden)

    Luis López

    2012-11-01

    Full Text Available The graphical documentation process of archaeological pieces requires the active involvement of a professional artist to recreate beautiful illustrations using a wide variety of expressive techniques. Frequently, the artist’s work is limited by the inconvenience of working only with the photographs of the pieces he is going to illustrate. This paper presents a software tool that allows the easy generation of illustrations in real time from 3D scanned models. The developed interface allows the user to simulate very elaborate artistic styles through the creation of diagrams by using the available virtual lights. The software processes the diagrams to render an illustration from any given angle or position. Among the available virtual lights, there are well known techniques as silhouettes enhancement, hatching or toon shading.

  1. The history and principles of optical computed tomography for scanning 3-D radiation dosimeters: 2008 update

    Energy Technology Data Exchange (ETDEWEB)

    Doran, Simon J [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Sutton, Surrey (United Kingdom); Department of Physics, University of Surrey, Surrey (United Kingdom)], E-mail: Simon.Doran@icr.ac.uk

    2009-05-01

    The current status of optical CT for 3-D radiation dosimetry is reviewed. The technique is first placed in its historical context, pointing out the relationship with other methods of optical imaging and showing how optical-CT has emerged independently in several different fields and under different names. The theoretical background of the method is described briefly and this provides the foundation for an explanation of the different types of scanner. The relative advantages and disadvantages of instruments based on scanned lasers and pixelated (area) detectors are presented. The latest generation of 'fast laser scanners' is described and the review is concluded with a discussion of the different radiation-sensitive materials used as samples in optical CT.

  2. Scanning protocol of dual-source computed tomography for aortic dissection

    International Nuclear Information System (INIS)

    Zhai Mingchun; Wang Yongmei

    2013-01-01

    Objective: To find a dual-source CT scanning protocol which can obtain high image quality with low radiation dose for diagnosis of aortic dissection. Methods: Total 120 patients with suspected aortic dissection were randomly and equally assigned into three groups. Patients in Croup A were performed CTA exam with prospectively electrocardiogram- gated high pitch spiral mode (FLASH). Patients in Croup B were performed CTA exam with retrospective electrocardiogram- gated spiral mode. Patients in Croup C were performed CTA exam with conventional mode which no electrocardiogram-gated. The image quality, radiation dose, advantages and disadvantages among the three scan protocol were analyzed. Results: For image quality, seventeen, twenty two and one patients in group A were granted to grade 1, 2, 3 respectively, and none was in grade 4; thirty three and seven patients in group B were granted to grade 1, 2, respectively, and none was in grade 3 and 4; fourteen and twenty six patients in group C were granted to grade 3, 4, respectively, and none was in grade 1 and 2. There was no significant difference between group A and B in image quality. Compared with the image quality, Group A and B were significantly higher than Group C. Mean effective radiation dose of Croup A, B and C were 7.7±0.4 mSv, 33.11±3.38 mSv, and 7.6±0.68 mSv, respectively. Group B was significantly higher than Groups A and C (P<0.05, P<0.05, respectively), and there was no significant difference between Group A and C (P=0.826). Conclusions: Prospectively electrocardiogram-gated high pitch spiral mode can be the first line protocol for evaluation of aortic dissection. It can achieve high image quality with low radiation dose. Conventional mode with no electrocardiogram-gated can be selectively used for Stanford B aortic dissection. (authors)

  3. Multidetector computed tomography for the assessment of adnexal Mass: Is unenhenced CT scan necessary?

    International Nuclear Information System (INIS)

    Jung, Sung Il; Park, Hee Sun; Kim, Young Jun; Jeon, Hae Jeong

    2014-01-01

    To compare the diagnostic performance and radiation dose between contrast-enhanced CT (ECT) alone, and combined unenhanced and contrast-enhanced CT (UE + ECT) for the assessment of adnexal mass. This retrospective study was approved by the Institutional Review Board. A total of 146 consecutive patients (mean age, 41.1 years) who underwent preoperative unenhanced and contrast-enhanced multidetector CT of the pelvis and had adnexal masses found at surgery were included. Two readers independently evaluated the likelihood of adnexal malignancy on a 5-point scale on two different imaging datasets (ECT alone and UE + ECT). The area under the receiver operating characteristic curve (AUC) was used to evaluate diagnostic performance. Radiation dose to patients was calculated by the volume CT dose index (CTDIvol) and the dose length products (DLP) on each dataset. Of the total 178 adnexal masses, 133 masses were benign and 45 masses were malignant. For both readers, there is no significant difference of AUC values between ECT alone and UE + ECT for the detection of adnexal malignancy (reader 1, 0.93 vs. 0.95; reader 2, 0.92 vs. 0.91) (p > 0.05). The mean CTDIvol (12.6 ± 2.2 mGy) and DLP (641.2 ± 137.2 mGy) of ECT alone was significantly lower than the mean CTDIvol (21.5 ± 2.7 mGy) and DLP (923.6 ± 158.8 mGy) of UE + ECT (p < 0.0001). The use of unenhanced CT scan in addition to contrast-enhanced CT scan does not improve the detection of adnexal malignancy, but increases radiation exposure.

  4. A system level boundary scan controller board for VME applications [to CERN experiments

    CERN Document Server

    Cardoso, N; Da Silva, J C

    2000-01-01

    This work is the result of a collaboration between INESC and LIP in the CMS experiment being conducted at CERN. The collaboration addresses the application of boundary scan test at system level namely the development of a VME boundary scan controller (BSC) board prototype and the corresponding software. This prototype uses the MTM bus existing in the VME64* backplane to apply the 1149.1 test vectors to a system composed of nineteen boards, called here units under test (UUTs). A top-down approach is used to describe our work. The paper begins with some insights about the experiment being conducted at CERN, proceed with system level considerations concerning our work and with some details about the BSC board. The results obtained so far and the proposed work is reviewed in the end of this contribution. (11 refs).

  5. Scanning with a Total Information Storage and Controlled Data Presentation System

    Energy Technology Data Exchange (ETDEWEB)

    Rejali, A. M.; Gregg, E. C.; Voelker, W. H.; Friedell, H. L. [Case Western Reserve University, Cleveland, OH (United States)

    1969-01-15

    This presentation demonstrates improved clinical results obtained from storing all available information received by the detector or detectors without prior modifications in a permanent memory. Permanently stored information is modified later with a special electronic imaging system with kinescope presentation in black and white or colour. Under carefully controlled circumstances this system permits immediate and innumerable degrees of erase and contrast enhancement or colour coding in fractions of a second. A profile representing the count-rate through any slice in the scanned area may be performed to determine relative distribution of radioisotopes. The advantage of this system and various clinical results in scans of myocardiums, pancreas, cardiac blood pool, placenta, etc. will be presented. (author)

  6. Future Communication, Computing, Control and Management Volume 2

    CERN Document Server

    2012-01-01

    This volume contains revised and extended research articles written by prominent researchers participating in the ICF4C 2011 conference. 2011 International Conference on Future Communication, Computing, Control and Management (ICF4C 2011) has been held on December 16-17, 2011, Phuket, Thailand. Topics covered include intelligent computing, network management, wireless networks, telecommunication, power engineering, control engineering, Signal and Image Processing, Machine Learning, Control Systems and Applications, The book will offer the states of arts of tremendous advances in Computing, Communication, Control, and Management and also serve as an excellent reference work for researchers and graduate students working on Computing, Communication, Control, and Management Research.

  7. Future Communication, Computing, Control and Management Volume 1

    CERN Document Server

    2012-01-01

    This volume contains revised and extended research articles written by prominent researchers participating in the ICF4C 2011 conference. 2011 International Conference on Future Communication, Computing, Control and Management (ICF4C 2011) has been held on December 16-17, 2011, Phuket, Thailand. Topics covered include intelligent computing, network management, wireless networks, telecommunication, power engineering, control engineering, Signal and Image Processing, Machine Learning, Control Systems and Applications, The book will offer the states of arts of tremendous advances in Computing, Communication, Control, and Management and also serve as an excellent reference work for researchers and graduate students working on Computing, Communication, Control, and Management Research.

  8. Future Computing, Communication, Control and Management Volume 2

    CERN Document Server

    2012-01-01

    This volume contains revised and extended research articles written by prominent researchers participating in the ICF4C 2011 conference. 2011 International Conference on Future Communication, Computing, Control and Management (ICF4C 2011) has been held on December 16-17, 2011, Phuket, Thailand. Topics covered include intelligent computing, network management, wireless networks, telecommunication, power engineering, control engineering, Signal and Image Processing, Machine Learning, Control Systems and Applications, The book will offer the states of arts of tremendous advances in Computing, Communication, Control, and Management and also serve as an excellent reference work for researchers and graduate students working on Computing, Communication, Control, and Management Research.

  9. Nanoscale control of reversible chemical reaction between fullerene C60 molecules using scanning tunneling microscope.

    Science.gov (United States)

    Nakaya, Masato; Kuwahara, Yuji; Aono, Masakazu; Nakayama, Tomonobu

    2011-04-01

    The nanoscale control of reversible chemical reactions, the polymerization and depolymerization between C60 molecules, has been investigated. Using a scanning tunneling microscope (STM), the polymerization and depolymerization can be controlled at designated positions in ultrathin films of C60 molecules. One of the two chemical reactions can be selectively induced by controlling the sample bias voltage (V(s)); the application of negative and positive values of V(s) results in polymerization and depolymerization, respectively. The selectivity between the two chemical reactions becomes extremely high when the thickness of the C60 film increases to more than three molecular layers. We conclude that STM-induced negative and positive electrostatic ionization are responsible for the control of the polymerization and depolymerization, respectively.

  10. Reducing the throughput time of the diagnostic track involving CT scanning with computer simulation

    International Nuclear Information System (INIS)

    Lent, Wineke A.M. van; Deetman, Joost W.; Teertstra, H. Jelle; Muller, Sara H.; Hans, Erwin W.; Harten, Wim H. van

    2012-01-01

    Introduction: To examine the use of computer simulation to reduce the time between the CT request and the consult in which the CT report is discussed (diagnostic track) while restricting idle time and overtime. Methods: After a pre implementation analysis in our case study hospital, by computer simulation three scenarios were evaluated on access time, overtime and idle time of the CT; after implementation these same aspects were evaluated again. Effects on throughput time were measured for outpatient short-term and urgent requests only. Conclusion: The pre implementation analysis showed an average CT access time of 9.8 operating days and an average diagnostic track of 14.5 operating days. Based on the outcomes of the simulation, management changed the capacity for the different patient groups to facilitate a diagnostic track of 10 operating days, with a CT access time of 7 days. After the implementation of changes, the average diagnostic track duration was 12.6 days with an average CT access time of 7.3 days. The fraction of patients with a total throughput time within 10 days increased from 29% to 44% while the utilization remained equal with 82%, the idle time increased by 11% and the overtime decreased by 82%. The fraction of patients that completed the diagnostic track within 10 days improved with 52%. Computer simulation proved useful for studying the effects of proposed scenarios in radiology management. Besides the tangible effects, the simulation increased the awareness that optimizing capacity allocation can reduce access times.

  11. Reducing the throughput time of the diagnostic track involving CT scanning with computer simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lent, Wineke A.M. van, E-mail: w.v.lent@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); University of Twente, IGS Institute for Innovation and Governance Studies, Department of Health Technology Services Research (HTSR), Enschede (Netherlands); Deetman, Joost W., E-mail: j.deetman@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Teertstra, H. Jelle, E-mail: h.teertstra@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Muller, Sara H., E-mail: s.muller@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Hans, Erwin W., E-mail: e.w.hans@utwente.nl [University of Twente, School of Management and Governance, Dept. of Industrial Engineering and Business Intelligence Systems, Enschede (Netherlands); Harten, Wim H. van, E-mail: w.v.harten@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); University of Twente, IGS Institute for Innovation and Governance Studies, Department of Health Technology Services Research (HTSR), Enschede (Netherlands)

    2012-11-15

    Introduction: To examine the use of computer simulation to reduce the time between the CT request and the consult in which the CT report is discussed (diagnostic track) while restricting idle time and overtime. Methods: After a pre implementation analysis in our case study hospital, by computer simulation three scenarios were evaluated on access time, overtime and idle time of the CT; after implementation these same aspects were evaluated again. Effects on throughput time were measured for outpatient short-term and urgent requests only. Conclusion: The pre implementation analysis showed an average CT access time of 9.8 operating days and an average diagnostic track of 14.5 operating days. Based on the outcomes of the simulation, management changed the capacity for the different patient groups to facilitate a diagnostic track of 10 operating days, with a CT access time of 7 days. After the implementation of changes, the average diagnostic track duration was 12.6 days with an average CT access time of 7.3 days. The fraction of patients with a total throughput time within 10 days increased from 29% to 44% while the utilization remained equal with 82%, the idle time increased by 11% and the overtime decreased by 82%. The fraction of patients that completed the diagnostic track within 10 days improved with 52%. Computer simulation proved useful for studying the effects of proposed scenarios in radiology management. Besides the tangible effects, the simulation increased the awareness that optimizing capacity allocation can reduce access times.

  12. Neurologic, neuropsychologic, and computed cranial tomography scan abnormalities in 2- to 10-year survivors of small-cell lung cancer.

    Science.gov (United States)

    Johnson, B E; Becker, B; Goff, W B; Petronas, N; Krehbiel, M A; Makuch, R W; McKenna, G; Glatstein, E; Ihde, D C

    1985-12-01

    In order to evaluate the relationship between neurologic function and cranial irradiation, 20 patients treated on National Cancer Institute (NCI) small-cell lung cancer (SCLC) trials who were alive and free of cancer 2.4 to 10.6 years (median, 6.2) from the start of therapy were studied. All were tested with a neurologic history and examination, mental status examination, neuropsychologic testing, and review of serial computed cranial tomography (CCT) scans. Fifteen patients had been treated with prophylactic cranial irradiation (PCI), two patients with therapeutic cranial irradiation, and three received no cranial irradiation. All patients but one were ambulatory and none were institutionalized. Fifteen patients (75%) had neurologic complaints, 13 (65%) had abnormal neurologic examinations, 12 (60%) had abnormal mental status examinations, 13 (65%) had abnormal neuropsychologic testing, and 15 (75%) had abnormal CCT scans. Compared with those given low-dose maintenance chemotherapy during PCI using 200 to 300 rad per fraction, patients who were given high-dose induction chemotherapy during the time of cranial irradiation or large radiotherapy fractions (400 rad) were more likely to have abnormal mental status examinations (6/6 v 4/9) and abnormal neuropsychologic tests (6/6 v 4/9), but no major difference in CCT findings was present. CCT scans in the majority of cases (11/18) showed progressive ventricular dilatation or cerebral atrophy up to 8 years after stopping therapy. We conclude neurologic abnormalities are common in long-term survivors of SCLC, and may be more prominent in patients given high-dose chemotherapy during cranial irradiation or treated with large radiotherapy fractions. The CCT scan abnormalities are common and progressive years after prophylactic cranial irradiation and chemotherapy are stopped.

  13. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  14. Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

    International Nuclear Information System (INIS)

    Tasanapanont, Jintana; Apisariyakul, Janya; Wattanachai, Tanapan; Jotikasthira, Dhirawat; Sriwilas, Patiyut; Midtboe, Marit

    2017-01-01

    The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient (ICC) was used to assess intraobserver reliability. The root surface area measurements (230.11±41.97 mm"2) obtained using CBCT were slightly greater than those (229.31±42.46 mm2) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth

  15. Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tasanapanont, Jintana; Apisariyakul, Janya; Wattanachai, Tanapan; Jotikasthira, Dhirawat [Dept. of Orthodontics and Pediatric Dentistry, Faculty of Dentistry, Chiang Mai University, Chiang Mai (Thailand); Sriwilas, Patiyut [Dept. of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok (Thailand); Midtboe, Marit [Dept. of Clinical Dentistry - Orthodontics, Faculty of Medicine and Dentistry, University of Bergen, Bergen (Norway)

    2017-06-15

    The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient (ICC) was used to assess intraobserver reliability. The root surface area measurements (230.11±41.97 mm{sup 2}) obtained using CBCT were slightly greater than those (229.31±42.46 mm2) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

  16. [Application of second generation dual-source computed tomography dual-energy scan mode in detecting pancreatic adenocarcinoma].

    Science.gov (United States)

    Xue, Hua-dan; Liu, Wei; Sun, Hao; Wang, Xuan; Chen, Yu; Su, Bai-yan; Sun, Zhao-yong; Chen, Fang; Jin, Zheng-yu

    2010-12-01

    To analyze the clinical value of multiple sequences derived from dual-source computed tomography (DSCT) dual-energy scan mode in detecting pancreatic adenocarcinoma. Totally 23 patients with clinically or pathologically diagnosed pancreatic cancer were enrolled in this retrospective study. DSCT (Definition Flash) was used and dual-energy scan mode was used in their pancreatic parenchyma phase scan (100kVp/230mAs and Sn140kVp/178mAs) . Mono-energetic 60kev, mono-energetic 80kev, mono-energetic 100kev, mono-energetic 120kev, linear blend image, non-linear blend image, and iodine map were acquired. pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were calculated. One-way ANOVA was used for the comparison of diagnostic values of the above eight different dual-energy derived sequences for pancreatic cancer. The pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were significantly different among eight sequences (P<0.05) . Mono-energetic 60kev image showed the largest parenchyma-tumor CT value [ (77.53 ± 23.42) HU] , and iodine map showed the lowest tumor/parenchyma enhancement ratio (0.39?0.12) and the largest contrast to noise ratio (4.08 ± 1.46) . Multiple sequences can be derived from dual-energy scan mode with DSCT via multiple post-processing methods. Integration of these sequences may further improve the sensitivity of the multislice spiral CT in the diagnosis of pancreatic cancer.

  17. Micro-computer control for super-critical He generation

    International Nuclear Information System (INIS)

    Tamada, Noriharu; Sekine, Takehiro; Tomiyama, Sakutaro

    1979-01-01

    The development of a large scale refrigeration system is being stimulated by new superconducting techniques representated by a superconducting power cable and a magnet. For the practical operation of such a large system, an automatic control system with a computer is required, because it can attain an effective and systematic operation. For this reason, we examined and developed micro-computer control techniques for supercritical He generation, as a simplified control model of the refrigeration system. The experimental results showed that the computer control system can attain fine controlability, even if the control element is only one magnetic valve, but a BASIK program language of micro-computer, which is convinient and generaly used, isn't enough one to control a more complicated system, because of its low calculating speed. Then we conclude that a more effective program language for micro-computer must be developed to realize practical refrigeration control. (author)

  18. Rapid computation of single PET scan rest-stress myocardial blood flow parametric images by table look up.

    Science.gov (United States)

    Guehl, Nicolas J; Normandin, Marc D; Wooten, Dustin W; Rozen, Guy; Ruskin, Jeremy N; Shoup, Timothy M; Woo, Jonghye; Ptaszek, Leon M; Fakhri, Georges El; Alpert, Nathaniel M

    2017-09-01

    We have recently reported a method for measuring rest-stress myocardial blood flow (MBF) using a single, relatively short, PET scan session. The method requires two IV tracer injections, one to initiate rest imaging and one at peak stress. We previously validated absolute flow quantitation in ml/min/cc for standard bull's eye, segmental analysis. In this work, we extend the method for fast computation of rest-stress MBF parametric images. We provide an analytic solution to the single-scan rest-stress flow model which is then solved using a two-dimensional table lookup method (LM). Simulations were performed to compare the accuracy and precision of the lookup method with the original nonlinear method (NLM). Then the method was applied to 16 single scan rest/stress measurements made in 12 pigs: seven studied after infarction of the left anterior descending artery (LAD) territory, and nine imaged in the native state. Parametric maps of rest and stress MBF as well as maps of left (f LV ) and right (f RV ) ventricular spill-over fractions were generated. Regions of interest (ROIs) for 17 myocardial segments were defined in bull's eye fashion on the parametric maps. The mean of each ROI was then compared to the rest (K 1r ) and stress (K 1s ) MBF estimates obtained from fitting the 17 regional TACs with the NLM. In simulation, the LM performed as well as the NLM in terms of precision and accuracy. The simulation did not show that bias was introduced by the use of a predefined two-dimensional lookup table. In experimental data, parametric maps demonstrated good statistical quality and the LM was computationally much more efficient than the original NLM. Very good agreement was obtained between the mean MBF calculated on the parametric maps for each of the 17 ROIs and the regional MBF values estimated by the NLM (K 1map LM  = 1.019 × K 1 ROI NLM  + 0.019, R 2  = 0.986; mean difference = 0.034 ± 0.036 mL/min/cc). We developed a table lookup method for fast

  19. Craniofacial fibrous dysplasia: Report of a case using computed tomographic scan diagnosis

    Directory of Open Access Journals (Sweden)

    Nikhil Diwan

    2013-01-01

    Full Text Available Fibro-osseous lesions are benign mesenchymal tumors in which mineralized tissue, blood vessels, and giant cells, in varying proportions, replace normal bone. Although this group of lesions includes reactive lesions, harmatomas, and neoplasms, they cannot be distinguished only on the basis of the histopathology which can only confirm their common fibro-osseous nature. Definitive diagnosis requires thorough radiological evaluation. Computed tomographic images of craniofacial fibrous dysplasia on bone windows may be helpful and allow precise pre-operative diagnosis and surgical planning.

  20. Radiation Dose to the Lens of the Eye from Computed Tomography Scans of the Head

    Science.gov (United States)

    Januzis, Natalie Ann

    While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient's medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods. The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data. The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult. First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion

  1. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

    Science.gov (United States)

    Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-03-01

    This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

  2. Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: Pilot study

    International Nuclear Information System (INIS)

    Li Ping; Napel, Sandy; Acar, Burak; Paik, David S.; Jeffrey, R. Brooke Jr.; Beaulieu, Christopher F.

    2004-01-01

    Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wall to be collapsed, covered with water, and/or covered with retained stool, patients are scanned in both prone and supine positions. We believe that both reading efficiency and computer aided detection (CAD) of CTC images can be improved by accurate registration of data from the supine and prone positions. We developed a two-stage approach that first registers the colonic central paths using a heuristic and automated algorithm and then matches polyps or polyp candidates (CAD hits) by a statistical approach. We evaluated the registration algorithm on 24 patient cases. After path registration, the mean misalignment distance between prone and supine identical anatomic landmarks was reduced from 47.08 to 12.66 mm, a 73% improvement. The polyp registration algorithm was specifically evaluated using eight patient cases for which radiologists identified polyps separately for both supine and prone data sets, and then manually registered corresponding pairs. The algorithm correctly matched 78% of these pairs without user input. The algorithm was also applied to the 30 highest-scoring CAD hits in the prone and supine scans and showed a success rate of 50% in automatically registering corresponding polyp pairs. Finally, we computed the average number of CAD hits that need to be manually compared in order to find the correct matches among the top 30 CAD hits. With polyp registration, the average number of comparisons was 1.78 per polyp, as opposed to 4.28 comparisons without polyp registration

  3. Operators manual for a computer controlled impedance measurement system

    Science.gov (United States)

    Gordon, J.

    1987-02-01

    Operating instructions of a computer controlled impedance measurement system based in Hewlett Packard instrumentation are given. Hardware details, program listings, flowcharts and a practical application are included.

  4. Smart controller based scaler rate-meter for gamma column scanning application

    International Nuclear Information System (INIS)

    Narender Reddy, J.; Dhanajay Reddy, Y.; Dheeraj Reddy, J.

    2001-01-01

    A smart, controller based Scaler Rate-meter with scintillation probe for Gamma column scanning has been developed and made available. Designed to have advanced features with state-of-art electronic devices, hardware features include built-in adj. HV, amplifier- SCA, controller based data acquisition card, LCD display module for visualization of, HV set, preset and elapsed times, counts/count rate, column height and other programmable parameters. User interface is through a built-in programmable key pad, for instrument control, data acquisition, storage. Powerful embedded software provides all the above functions. Unit has capability to store up to 5000 readings. Data readings stored can be downloaded into a PC/lap top to generate a plot of count rate Vs column height, which is a signature for the column under study. Scintillation Probe design facilitates connection to the main unit through a single cable, permitting lengths up to 30 meters from the main unit. (author)

  5. Surface modification of poly(dimethylsiloxane) for controlling biological cells' adhesion using a scanning radical microjet

    International Nuclear Information System (INIS)

    Tan, Helen M.L.; Fukuda, H.; Akagi, T.; Ichiki, T.

    2007-01-01

    A scanning radical microjet (SRMJ) equipment using oxygen microplasma has been developed and successfully applied for controlling biological cells' attachment on biocompatible polymer material, poly(dimethylsiloxane) (PDMS). The radical microjet has advantages in localized and high-rate surface treatment. Moreover, maskless hydrophilic patterning using SRMJ has been demonstrated to be applicable to patterned cell cultivation which is useful in emerging biotechnological field such as tissue engineering and cell-based biosensors. Since control of PDMS surface properties is an indispensable prerequisite for cells' attachment, effects of oxygen flow rates and treatment time on localized hydrophilic patterning of PDMS surfaces were first investigated for controlling HeLa cells' (human epitheloid carcinoma cell line) attachment. Relationships between surface conditions of treated PDMS films and attached cell density are also discussed based on surface properties analyzed using atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS)

  6. Nasal Anthropometry on Facial Computed Tomography Scans for Rhinoplasty in Koreans

    Directory of Open Access Journals (Sweden)

    Kyung Min Moon

    2013-09-01

    Full Text Available BackgroundCephalometric analysis is essential for planning treatment in maxillofacial and aesthetic facial surgery. Although photometric analysis of the Korean nose has been attempted in the past, anthropometry of the deeper nasal structures in the same population based on computerized tomography (CT has not been published. We therefore measured three anthropometric parameters of the nose on CT scans in our clinical series of patients.MethodsWe conducted the current retrospective study of a total of 100 patients (n=100 who underwent a CT-guided radiological measurement at our institution during a period ranging from January of 2008 to August of 2010. In these patients, we took three anthropometric measurements: the nasofrontal angle, the pyramidal angle, and the linear distance between the nasion and the tip of the nasal bone.ResultsThe mean nasofrontal angle was 131.14° in the male patients and 140.70° in the female patients. The mean linear distance between the nasion and the tip of the nasal bone was 21.28 mm and 18.02 mm, respectively. The mean nasal pyramidal angle was 112.89° and 103.25° at the level of the nasal root, 117.49° and 115.60° at the middle level of the nasal bone, and 127.99° and 125.04° at the level of the tip of the nasal bone, respectively.ConclusionsIn conclusion, our data will be helpful in the preparation of silicone implants for augmentation and/or corrective rhinoplasty in ethnic Korean people.

  7. A review of the benefits and rationale of viewing liver window settings for abdominal computed tomography scans

    International Nuclear Information System (INIS)

    Dang, Tan; Mandarano, Giovanni

    2006-01-01

    There have been many different opinions over the efficacy of routinely incorporating liver-window settings in abdominal computed tomography (CT) scans. As a result, different clinical centres have varying protocols for incorporating liver-windows for abdominal CT scans. This investigation aims to explore and determine whether various clinical centres throughout Victoria use liver-window settings selectively or routinely and their justification for doing so. An additional purpose is also to assess the benefits and rationale of liver-window settings in supplementing routine soft-tissue-windows for abdominal CT examinations by reviewing evidenced-based studies. Surveys were sent out to CT supervisors at various clinical centres, including private and public institutions. This achieved an overall response rate of 74 per cent. Results indicate that the majority of clinical centres throughout Victoria routinely incorporate liver-window settings for all abdominal CT examinations. Forty four per cent (11/25) of respondents stated that they utilise liver-window settings selectively for abdominal CT examinations. Most of these respondents (7/11 = 63 per cent) believed that soft-tissue-window settings alone are adequate to demonstrate hepatic lesions; particularly if intravenous contrast media is used and the liver is captured in the arterial, venous and/or delayed phases. The benefits and rationale of incorporating liver-window settings for all abdominal computed tomography scans has been questioned by two well noted studies in the United States. These evidence-based studies suggest that such additional settings do not offer further advantages in detecting hepatic disease, when compared to soft-tissue-windows alone. Review of the available literature provides additional evidence suggesting that the routine use of liver-window settings in conjunction with soft-tissue-windows offers no further advantages in the detection of hepatic diseases. This investigation found, however

  8. Computer control in a compton scattering spectrometer

    International Nuclear Information System (INIS)

    Cui Ningzhuo; Chen Tao; Gong Zhufang; Yang Baozhong; Mo Haiding; Hua Wei; Bian Zuhe

    1995-01-01

    The authors introduced the hardware and software of computer autocontrol of calibration and data acquisition in a Compton Scattering spectrometer which consists of a HPGe detector, Amplifiers and a MCA

  9. Automated segmentation of pulmonary structures in thoracic computed tomography scans: a review

    International Nuclear Information System (INIS)

    Van Rikxoort, Eva M; Van Ginneken, Bram

    2013-01-01

    Computed tomography (CT) is the modality of choice for imaging the lungs in vivo. Sub-millimeter isotropic images of the lungs can be obtained within seconds, allowing the detection of small lesions and detailed analysis of disease processes. The high resolution of thoracic CT and the high prevalence of lung diseases require a high degree of automation in the analysis pipeline. The automated segmentation of pulmonary structures in thoracic CT has been an important research topic for over a decade now. This systematic review provides an overview of current literature. We discuss segmentation methods for the lungs, the pulmonary vasculature, the airways, including airway tree construction and airway wall segmentation, the fissures, the lobes and the pulmonary segments. For each topic, the current state of the art is summarized, and topics for future research are identified. (topical review)

  10. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...... patients. With the same SPECT the distribution of PAO was measured after intravenous injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6-10 mm (HR) and 15-20 mm (LR). PAO images showed close resemblance to 133Xe CBF tomograms. Only 20 per cent...... of the (decay corrected) brain counts were lost during 24 hours....

  11. Effects of megavoltage computed tomographic scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy.

    Science.gov (United States)

    Zhu, Jian; Bai, Tong; Gu, Jiabing; Sun, Ziwen; Wei, Yumei; Li, Baosheng; Yin, Yong

    2018-04-27

    To evaluate the effect of pretreatment megavoltage computed tomographic (MVCT) scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy. Both anthropomorphic heterogeneous chest and pelvic phantoms were planned with virtual targets by TomoTherapy Physicist Station and were scanned with TomoTherapy megavoltage image-guided radiotherapy (IGRT) system consisted of six groups of options: three different acquisition pitches (APs) of 'fine', 'normal' and 'coarse' were implemented by multiplying 2 different corresponding reconstruction intervals (RIs). In order to mimic patient setup variations, each phantom was shifted 5 mm away manually in three orthogonal directions respectively. The effect of MVCT scan options was analyzed in image quality (CT number and noise), adaptive dose calculation deviations and positional correction variations. MVCT scanning time with pitch of 'fine' was approximately twice of 'normal' and 3 times more than 'coarse' setting, all which will not be affected by different RIs. MVCT with different APs delivered almost identical CT numbers and image noise inside 7 selected regions with various densities. DVH curves from adaptive dose calculation with serial MVCT images acquired by varied pitches overlapped together, where as there are no significant difference in all p values of intercept & slope of emulational spinal cord (p = 0.761 & 0.277), heart (p = 0.984 & 0.978), lungs (p = 0.992 & 0.980), soft tissue (p = 0.319 & 0.951) and bony structures (p = 0.960 & 0.929) between the most elaborated and the roughest serials of MVCT. Furthermore, gamma index analysis shown that, compared to the dose distribution calculated on MVCT of 'fine', only 0.2% or 1.1% of the points analyzed on MVCT of 'normal' or 'coarse' do not meet the defined gamma criterion. On chest phantom, all registration errors larger than 1 mm appeared at superior-inferior axis, which cannot be avoided with the smallest AP and RI

  12. Evaluation of radiation dose in chest scan with enhanced dual-source computed tomography in children with congenital heart disease

    International Nuclear Information System (INIS)

    Hou Zhihui; Lu Bin; Tang Xiang; Han Lei

    2011-01-01

    Objective: To evaluate the radiation dose from enhanced dual-source computed Tomography (DSCT) scan on children with congenital heart disease (CHD). Methods: Seventy children with CHD, age from 1 month to 8 years old, were scanned with enhanced DSCT. Children were divided by age into 5 years old group. The differences among three groups were tested by F test. Then, the SNK test was used to compare the difference between each group. Multiple linear regression analysis was used to test the relationship of dose length product (DLP) with the age, weight, voltage, current, pitch and scan sheet. Results: The average value of DLP was (144.46± 74.07) mGy·cm for all the 70 cases, and that of effective does (ED) was (4.68±2.34) mSv. There were significant differences of DLP among the 3 groups [ 5 years (208.00±73.87) mGy · cm, F=8.26, P=0.0009]. The SNK test showed statistical differences of DLP between 5 years old group (q=5.21, 6.52, P=0.009, 0.004). The difference of DLP between 1-5 years old group and > 5 years old group did not reach significant (q=0.28, P=0.48). The differences of ED was not statistically significant among the three groups [ 5 years (3.74±1.33) mSv, F=0.54, P=0.59]. DLP was positively correlated with age (4.3 years, r=0.54186, P=0.0008), weight (12.1 kg, r=0.56371, P=0.0004), voltage [(95.48±6.99) kV, r=0.63269, P<0.01], current [(138.55±40.67) mA, r=0.79608, P< 0.0001] and scan sheet (236.10±46.51, r=0.72192, P<0.01). DLP was negative correlated with pitch (0.48±0.03, r=-0.46693, P=0.0047). Conclusion: Higher DLP was observed in children over 1 year old under enhanced DSCT scan, but ED was not statistically significant among the three groups due to the higher K value in the children under 1 year old. (authors)

  13. Screening in veterinary drug analysis and sports doping control based on full-scan, accurate-mass spectrometry

    NARCIS (Netherlands)

    Peters, R.J.B.; Stolker, A.A.M.; Mol, J.G.J.; Lommen, A.; Lyris, E.; Angelis, Y.S.; Vonaparti, A.; Stamou, M.; Georgakopoulos, C.G.; Nielen, M.W.F.

    2010-01-01

    A common trend in food contaminants and sports doping control is towards a limited number of targeted, full-scan, accurate-mass spectrometry (MS) methods based on time-of-flight (TOF) or Fourier-transform orbital trap (Orbitrap) mass analyzers. Retrospective analysis of the full-scan datasets of

  14. Computed tomography scanning can monitor the effects of soil medium on root system development: An example of salt stress in corn

    Directory of Open Access Journals (Sweden)

    Sowmyalakshmi eSubramanian

    2015-04-01

    Full Text Available Seeds and young seedlings often encounter high soluble salt levels in the upmost soil layers, impeding vigorous growth by affecting root establishment. Computed tomography (CT scanning used at low X-ray doses can help study root development in such conditions non-destructively, because plants are allowed to grow throughout the experiment. Using a high-resolution Toshiba XVision CT scanner, we studied corn (Zea mays L. root growth under optimal and salt-stressed conditions in 3D and on a weekly basis over 3 weeks. Two groups of 3 corn plants were grown in the controlled environment of a growth chamber, in mid-sized plastic pots filled with sieved and autoclaved sand. Seedlings were subjected to first CT scanning one week after seed planting. Our main research objectives concerning root systems were: (i to quantify structural complexity from fractal dimensions estimated on skeletal 3-D images built from CT scanning data; (ii to measure growth from volumes and derived relative rates, after isolating primary and secondary roots from the soil medium in CT scanning data; and (iii to assess differences in complexity and growth per week and over Weeks 1–3 for groups of corn plants. Differences between groups were present from Week 1; starting in Week 2 secondary roots were present and could be isolated, which refined the complexity and growth analyses of root systems. Besides expected Week main effects (P < 0.01 or 0.05, Week x Group interaction (P < 0.05 or 0.10 and Group main effects were observed, which is remarkable given the small sample sizes. Graphical, quantitative and statistical analyses of CT scanning data were thus completed at an unprecedented level, and provided new and important insights regarding root system development. Repeated CT scanning is the key to a better understanding of the establishment in the soil medium of crop plants such as corn and the assessment of salt stress effects on developing root systems, in complexity and

  15. Evolutionary Computing for Intelligent Power System Optimization and Control

    DEFF Research Database (Denmark)

    This new book focuses on how evolutionary computing techniques benefit engineering research and development tasks by converting practical problems of growing complexities into simple formulations, thus largely reducing development efforts. This book begins with an overview of the optimization the...... theory and modern evolutionary computing techniques, and goes on to cover specific applications of evolutionary computing to power system optimization and control problems....

  16. Computer simulation system of neural PID control on nuclear reactor

    International Nuclear Information System (INIS)

    Chen Yuzhong; Yang Kaijun; Shen Yongping

    2001-01-01

    Neural network proportional integral differential (PID) controller on nuclear reactor is designed, and the control process is simulated by computer. The simulation result show that neutral network PID controller can automatically adjust its parameter to ideal state, and good control result can be gotten in reactor control process

  17. Robust semi-automatic segmentation of pulmonary subsolid nodules in chest computed tomography scans

    International Nuclear Information System (INIS)

    Lassen, B C; Kuhnigk, J-M; Van Ginneken, B; Van Rikxoort, E M; Jacobs, C

    2015-01-01

    The malignancy of lung nodules is most often detected by analyzing changes of the nodule diameter in follow-up scans. A recent study showed that comparing the volume or the mass of a nodule over time is much more significant than comparing the diameter. Since the survival rate is higher when the disease is still in an early stage it is important to detect the growth rate as soon as possible. However manual segmentation of a volume is time-consuming. Whereas there are several well evaluated methods for the segmentation of solid nodules, less work is done on subsolid nodules which actually show a higher malignancy rate than solid nodules. In this work we present a fast, semi-automatic method for segmentation of subsolid nodules. As minimal user interaction the method expects a user-drawn stroke on the largest diameter of the nodule. First, a threshold-based region growing is performed based on intensity analysis of the nodule region and surrounding parenchyma. In the next step the chest wall is removed by a combination of a connected component analyses and convex hull calculation. Finally, attached vessels are detached by morphological operations. The method was evaluated on all nodules of the publicly available LIDC/IDRI database that were manually segmented and rated as non-solid or part-solid by four radiologists (Dataset 1) and three radiologists (Dataset 2). For these 59 nodules the Jaccard index for the agreement of the proposed method with the manual reference segmentations was 0.52/0.50 (Dataset 1/Dataset 2) compared to an inter-observer agreement of the manual segmentations of 0.54/0.58 (Dataset 1/Dataset 2). Furthermore, the inter-observer agreement using the proposed method (i.e. different input strokes) was analyzed and gave a Jaccard index of 0.74/0.74 (Dataset 1/Dataset 2). The presented method provides satisfactory segmentation results with minimal observer effort in minimal time and can reduce the inter-observer variability for segmentation of

  18. Robust semi-automatic segmentation of pulmonary subsolid nodules in chest computed tomography scans

    Science.gov (United States)

    Lassen, B. C.; Jacobs, C.; Kuhnigk, J.-M.; van Ginneken, B.; van Rikxoort, E. M.

    2015-02-01

    The malignancy of lung nodules is most often detected by analyzing changes of the nodule diameter in follow-up scans. A recent study showed that comparing the volume or the mass of a nodule over time is much more significant than comparing the diameter. Since the survival rate is higher when the disease is still in an early stage it is important to detect the growth rate as soon as possible. However manual segmentation of a volume is time-consuming. Whereas there are several well evaluated methods for the segmentation of solid nodules, less work is done on subsolid nodules which actually show a higher malignancy rate than solid nodules. In this work we present a fast, semi-automatic method for segmentation of subsolid nodules. As minimal user interaction the method expects a user-drawn stroke on the largest diameter of the nodule. First, a threshold-based region growing is performed based on intensity analysis of the nodule region and surrounding parenchyma. In the next step the chest wall is removed by a combination of a connected component analyses and convex hull calculation. Finally, attached vessels are detached by morphological operations. The method was evaluated on all nodules of the publicly available LIDC/IDRI database that were manually segmented and rated as non-solid or part-solid by four radiologists (Dataset 1) and three radiologists (Dataset 2). For these 59 nodules the Jaccard index for the agreement of the proposed method with the manual reference segmentations was 0.52/0.50 (Dataset 1/Dataset 2) compared to an inter-observer agreement of the manual segmentations of 0.54/0.58 (Dataset 1/Dataset 2). Furthermore, the inter-observer agreement using the proposed method (i.e. different input strokes) was analyzed and gave a Jaccard index of 0.74/0.74 (Dataset 1/Dataset 2). The presented method provides satisfactory segmentation results with minimal observer effort in minimal time and can reduce the inter-observer variability for segmentation of

  19. Spontaneous Acute Mesenteroaxial Gastric Volvulus Diagnosed by Computed Tomography Scan in a Young Man.

    Science.gov (United States)

    Jabbour, Gaby; Afifi, Ibrahim; Ellabib, Mohamed; El-Menyar, Ayman; Al-Thani, Hassan

    2016-04-26

    Acute gastric volvulus is a surgical emergency that requires early recognition and treatment. Acute idiopathic mesenteroaxial gastric volvulus is a rare sub-type and there are few cases reported in children and there are even fewer reports in adults. We report a rare case of a 23-year-old man who presented with a 1-day history of vomiting, epigastric pain, distention, and constipation. The diagnosis for mesenteroaxial type gastric volvulus was confirmed by abdominal radiography and computed tomography. The patient was successfully treated by laparotomy with resection of the ischemic stomach wall and anastomosis. Acute spontaneous mesenteroaxial gastric volvulus is rare in adults and early diagnosis is challenging due to non-specific symptoms. A missed or delayed diagnosis may result in serious complications due to gastric obstruction. A patient presenting with severe epigastric pain and clinical evidence of gastric outlet obstruction should be considered as a surgical emergency to rule out gastric volvulus. High index of suspicion, early diagnosis and prompt surgical management are important for favorable outcome in patients with acute spontaneous gastric volvulus.

  20. Using 99mTc-DTPA radioaerosol inhalation lung scan as compared with computed tomography to detect lung injury in blunt chest trauma

    International Nuclear Information System (INIS)

    Esme, H.; Kaya, E.; Solak, O.; Yavuz, Y.; Yurumez, Y.; Sezer, M.

    2007-01-01

    Detection of pulmonary contusion in patients with blunt chest trauma is very important so as to commence therapy immediately to avoid irreversible damage. The purpose of our study was to evaluate the efficacy of technetium-99m diethylene triamine penta-acetic acid ( 99m Tc-DTPA) aerosol inhalation lung scintigraphy in comparison with chest computed tomography (CT) in the diagnosis of pulmonary contusion at acute blunt chest trauma. Twenty-nine patients with isolated blunt chest trauma were referred to the emergency department of our hospital, and nine healthy people participated in this study. Sixteen patients who had pulmonary contusion on CT scans were referred to as group 1, and 13 patients who had normal CT scans as group 2. Nine healthy people comprised a control group. 99m Tc-DTPA aerosol inhalation lung scintigraphy was performed on the first day in all patients. The mean half time (T 1/2 ) and penetration index values of 99m Tc-DTPA clearance were significantly lower in groups 1 and 2 compared with the control group. Among the three groups, there were no significant differences in arterial blood gas analysis except for PO 2 . The mean T 1/2 value of 99m Tc-DTPA clearance did correlate with PO 2 values but not with pH, PCO 2 , or HCO 3 values. 99m Tc-DTPA radioaerosol inhalation lung imaging may serve as a useful adjunct and supportive method to chest CT scanning for detecting mild pulmonary contusion. (author)

  1. EBR-II high-ramp transients under computer control

    International Nuclear Information System (INIS)

    Forrester, R.J.; Larson, H.A.; Christensen, L.J.; Booty, W.F.; Dean, E.M.

    1983-01-01

    During reactor run 122, EBR-II was subjected to 13 computer-controlled overpower transients at ramps of 4 MWt/s to qualify the facility and fuel for transient testing of LMFBR oxide fuels as part of the EBR-II operational-reliability-testing (ORT) program. A computer-controlled automatic control-rod drive system (ACRDS), designed by EBR-II personnel, permitted automatic control on demand power during the transients

  2. Computational intelligence applications in modeling and control

    CERN Document Server

    Vaidyanathan, Sundarapandian

    2015-01-01

    The development of computational intelligence (CI) systems was inspired by observable and imitable aspects of intelligent activity of human being and nature. The essence of the systems based on computational intelligence is to process and interpret data of various nature so that that CI is strictly connected with the increase of available data as well as capabilities of their processing, mutually supportive factors. Developed theories of computational intelligence were quickly applied in many fields of engineering, data analysis, forecasting, biomedicine and others. They are used in images and sounds processing and identifying, signals processing, multidimensional data visualization, steering of objects, analysis of lexicographic data, requesting systems in banking, diagnostic systems, expert systems and many other practical implementations. This book consists of 16 contributed chapters by subject experts who are specialized in the various topics addressed in this book. The special chapters have been brought ...

  3. Estimation of air void and aggregate spatial distributions in concrete under uniaxial compression using computer tomography scanning

    International Nuclear Information System (INIS)

    Wong, R.C.K.; Chau, K.T.

    2005-01-01

    Normal- and high-strength concrete cylinders (designed compressive strengths of 30 and 90 MPa at 28 days) were loaded uniaxially. Computer tomography (CT) scanning technique was used to examine the evolution of air voids inside the specimens at various loading states up to 85% of the ultimate compressive strength. The normal-strength concrete yielded a very different behaviour in changes of internal microstructure as compared to the high-strength concrete. There were significant instances of nucleation and growth in air voids in the normal-strength concrete specimen, while the increase in air voids in the high-strength concrete specimen was insignificant. In addition, CT images were used for mapping the aggregate spatial distributions within the specimens. No intrinsic anisotropy was detected from the fabric analysis

  4. Improving limited-projection-angle fluorescence molecular tomography using a co-registered x-ray computed tomography scan.

    Science.gov (United States)

    Radrich, Karin; Ale, Angelique; Ermolayev, Vladimir; Ntziachristos, Vasilis

    2012-12-01

    We examine the improvement in imaging performance, such as axial resolution and signal localization, when employing limited-projection-angle fluorescence molecular tomography (FMT) together with x-ray computed tomography (XCT) measurements versus stand-alone FMT. For this purpose, we employed living mice, bearing a spontaneous lung tumor model, and imaged them with FMT and XCT under identical geometrical conditions using fluorescent probes for cancer targeting. The XCT data was employed, herein, as structural prior information to guide the FMT reconstruction. Gold standard images were provided by fluorescence images of mouse cryoslices, providing the ground truth in fluorescence bio-distribution. Upon comparison of FMT images versus images reconstructed using hybrid FMT and XCT data, we demonstrate marked improvements in image accuracy. This work relates to currently disseminated FMT systems, using limited projection scans, and can be employed to enhance their performance.

  5. Three-dimensional analysis of rodent paranasal sinus cavities from X-ray computed tomography (CT) scans

    Science.gov (United States)

    Phillips, Jonathan E.; Ji, Lunan; Rivelli, Maria A.; Chapman, Richard W.; Corboz, Michel R.

    2009-01-01

    Continuous isometric microfocal X-ray computed tomography (CT) scans were acquired from an AKR/J mouse, Brown-Norway rat, and Hartley guinea pig. The anatomy and volume of the paranasal sinus cavities were defined from 2-dimensional (2-D) and 3-dimensional (3-D) CT images. Realistic 3-D images were reconstructed and used to determine the anterior maxillary, posterior maxillary, and ethmoid sinus cavity airspace volumes (mouse: 0.6, 0.7, and 0.7 mm3, rat: 8.6, 7.7, and 7.0 mm3, guinea pig: 63.5, 46.6 mm3, and no ethmoid cavity, respectively). The mouse paranasal sinus cavities are similar to the corresponding rat cavities, with a reduction in size, while the corresponding maxillary sinus cavities in the guinea pig are different in size, location, and architecture. Also, the ethmoid sinus cavity is connected by a common drainage pathway to the posterior maxillary sinus in mouse and rat while a similar ethmoid sinus was not present in the guinea pig. We conclude that paranasal sinus cavity airspace opacity (2-D) or volume (3-D) determined by micro-CT scanning may be used to conduct longitudinal studies on the patency of the maxillary sinus cavities of rodents. This represents a potentially useful endpoint for developing and testing drugs in a small animal model of sinusitis. PMID:19794893

  6. Non-Uniform Dose Mapping Controlled by Modulated Vertical and Horizontal Scans

    International Nuclear Information System (INIS)

    Ninomiya, S.; Kimura, Y.; Kudo, T.; Ochi, A.; Toda, R.; Tsukihara, M.; Sato, F.; Fuse, G.; Ueno, K.; Sugitani, M.

    2008-01-01

    Since geometries of semi-conductor devices continue to shrink, the requirement for each process becomes severer to keep uniformity of electrical parameters of the semi-conductor devices. A larger wafer also causes larger variations. Thus it has been strongly required for ion implantation process to compensate for the variations from other processes because of its good dose controllability. A newly developed mapping of intentional non-uniform dosage system, which is named 'MIND system', is implemented in SEN's single-wafer-type implanters. The MIND system controls both horizontal and vertical scan speed simultaneously. Intentional two-dimensional non-uniform profiles of sheet resistance, such as concentric and eccentric profiles, are obtained only by single-step ion implantation.

  7. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  8. Analyzing Dental Implant Sites From Cone Beam Computed Tomography Scans on a Tablet Computer: A Comparative Study Between iPad and 3 Display Systems.

    Science.gov (United States)

    Carrasco, Alejandro; Jalali, Elnaz; Dhingra, Ajay; Lurie, Alan; Yadav, Sumit; Tadinada, Aditya

    2017-06-01

    The aim of this study was to compare a medical-grade PACS (picture archiving and communication system) monitor, a consumer-grade monitor, a laptop computer, and a tablet computer for linear measurements of height and width for specific implant sites in the posterior maxilla and mandible, along with visualization of the associated anatomical structures. Cone beam computed tomography (CBCT) scans were evaluated. The images were reviewed using PACS-LCD monitor, consumer-grade LCD monitor using CB-Works software, a 13″ MacBook Pro, and an iPad 4 using OsiriX DICOM reader software. The operators had to identify anatomical structures in each display using a 2-point scale. User experience between PACS and iPad was also evaluated by means of a questionnaire. The measurements were very similar for each device. P-values were all greater than 0.05, indicating no significant difference between the monitors for each measurement. The intraoperator reliability was very high. The user experience was similar in each category with the most significant difference regarding the portability where the PACS display received the lowest score and the iPad received the highest score. The iPad with retina display was comparable with the medical-grade monitor, producing similar measurements and image visualization, and thus providing an inexpensive, portable, and reliable screen to analyze CBCT images in the operating room during the implant surgery.

  9. Isotopic analysis of plutonium by computer controlled mass spectrometry

    International Nuclear Information System (INIS)

    1974-01-01

    Isotopic analysis of plutonium chemically purified by ion exchange is achieved using a thermal ionization mass spectrometer. Data acquisition from and control of the instrument is done automatically with a dedicated system computer in real time with subsequent automatic data reduction and reporting. Separation of isotopes is achieved by varying the ion accelerating high voltage with accurate computer control

  10. Mapping allostery through computational glycine scanning and correlation analysis of residue-residue contacts.

    Science.gov (United States)

    Johnson, Quentin R; Lindsay, Richard J; Nellas, Ricky B; Fernandez, Elias J; Shen, Tongye

    2015-02-24

    Understanding allosteric mechanisms is essential for the physical control of molecular switches and downstream cellular responses. However, it is difficult to decode essential allosteric motions in a high-throughput scheme. A general two-pronged approach to performing automatic data reduction of simulation trajectories is presented here. The first step involves coarse-graining and identifying the most dynamic residue-residue contacts. The second step is performing principal component analysis of these contacts and extracting the large-scale collective motions expressed via these residue-residue contacts. We demonstrated the method using a protein complex of nuclear receptors. Using atomistic modeling and simulation, we examined the protein complex and a set of 18 glycine point mutations of residues that constitute the binding pocket of the ligand effector. The important motions that are responsible for the allostery are reported. In contrast to conventional induced-fit and lock-and-key binding mechanisms, a novel "frustrated-fit" binding mechanism of RXR for allosteric control was revealed.

  11. Status of automated nuclear scanning systems

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Preston, C.C.; McNeece, J.P.; Ruddy, F.H.

    1983-07-01

    Present day minicomputers and microprocessors enable a range of automation, from partial to total, of tasks once thought beyond approach. The status of three computer controlled systems for quantitative track measurements is reviewed. Two systems, the Hanford optical track scanner (HOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third systems, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Current limitations of these systems for quantitative track scanning are presented. Experimental uncertainties attained with these computer controlled systems are described using results obtained from reactor neutron dosimetry

  12. Secure cloud computing: benefits, risks and controls

    CSIR Research Space (South Africa)

    Carroll, M

    2011-08-01

    Full Text Available Cloud computing presents a new model for IT service delivery and it typically involves over-a-network, on-demand, self-service access, which is dynamically scalable and elastic, utilising pools of often virtualized resources. Through these features...

  13. Experiencing Brain-Computer Interface Control

    NARCIS (Netherlands)

    van de Laar, B.L.A.

    2016-01-01

    Brain-Computer Interfaces (BCIs) are systems that extract information from the user’s brain activity and employ it in some way in an interactive system. While historically BCIs were mainly catered towards paralyzed or otherwise physically handicapped users, the last couple of years applications with

  14. Abdominal fat-evaluation by use of single scan computed tomography; Computertomographische Bestimmung des intraabdominellen Fettvolumens mittels Einschicht-Messung

    Energy Technology Data Exchange (ETDEWEB)

    Jacobi, V. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Steinkamp, M. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Kirchner, J. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Fischer, H. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik; Diedrich, C.F. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik; Kollath, J. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik

    1997-02-01

    Purpose: Several studies emphasised the importance of the relationship between intraabdominal and total body adipose tissue as a risk factor for the development of metabolic or cardiovascular diseases. Therefore, the aim of the present study was to examine whether a single scan computed tomography is able to determine the whole intraabdominal fat volume with high accuracy and reproducibility. Materials and methods: Regions of interests (ROIs) were drawn manually for measuring intraabdominal fat in 51 unsuspicious abdominal CT. Results: The sexual differentiation of adipose tissue already described in a lot of studies could be confirmed in this study. Fat still predominates in females in lower half of the body (gynoid obesity). In men it predominates in the upper half (android obesity). Significant correlation concerning measuring the whole intraabdominal fat volume could be found in L1-level in women (r=0.992) and in L2-level in men (r=0.992). Measurement of a single scan enables us to assess whole intraabdominal fat volume due to a special formula. Conclusion: The determination of intraabdominal fat measured by a single scan computed tomography is a procedure associated with high accuracy and reproducibility. (orig.) [Deutsch] Ziel: Da in zahlreichen Studien hervorgehobene Bedeutung des intraabdominellen Fettgewebes gegenueber dem Gesamtkoerperfett als Risikofaktor fuer die Entwicklung metabolischer und kardiovaskulaerer Erkrankungen fordert ein Verfahren zur annaehernd exakten Bestimmung des intraabdominellen Fettgewebes. Ziel der vorliegenden Studie war zu pruefen, ob mit genuegender Genauigkeit die Verwendung einer Einschicht-Methode einen gezielten Einsatz der Computertomographie ermoeglicht und welche Lokalisation der zu waehlenden Schicht die aussagekraeftigste Messung ermoeglicht. Material und Methode: Anhand von 51 Computertomographien des Abdomens anderer Indikation (Normalbefunde) wurde das gesamte intraabdominelle Fettvolumen semiautomatisch mittels ROI

  15. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial.

    Science.gov (United States)

    Sierink, Joanne C; Treskes, Kaij; Edwards, Michael J R; Beuker, Benn J A; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G W; Luitse, Jan S K; Beenen, Ludo F M; Hollmann, Markus W; Goslings, J Carel

    2016-08-13

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in patients with trauma. We undertook an international, multicentre, randomised controlled trial at four hospitals in the Netherlands and one in Switzerland. Patients aged 18 years or older with trauma with compromised vital parameters, clinical suspicion of life-threatening injuries, or severe injury were randomly assigned (1:1) by ALEA randomisation to immediate total-body CT scanning or to a standard work-up with conventional imaging supplemented with selective CT scanning. Neither doctors nor patients were masked to treatment allocation. The primary endpoint was in-hospital mortality, analysed in the intention-to-treat population and in subgroups of patients with polytrauma and those with traumatic brain injury. The χ(2) test was used to assess differences in mortality. This trial is registered with ClinicalTrials.gov, number NCT01523626. Between April 22, 2011, and Jan 1, 2014, 5475 patients were assessed for eligibility, 1403 of whom were randomly assigned: 702 to immediate total-body CT scanning and 701 to the standard work-up. 541 patients in the immediate total-body CT scanning group and 542 in the standard work-up group were included in the primary analysis. In-hospital mortality did not differ between groups (total-body CT 86 [16%] of 541 vs standard work-up 85 [16%] of 542; p=0.92). In-hospital mortality also did not differ between groups in subgroup analyses in patients with polytrauma (total-body CT 81 [22%] of 362 vs standard work-up 82 [25%] of 331; p=0.46) and traumatic brain injury (68 [38%] of 178 vs 66 [44%] of 151; p=0.31). Three serious adverse events were reported in patients in the total-body CT group (1%), one in the standard work-up group (<1%), and

  16. SU-E-T-314: The Application of Cloud Computing in Pencil Beam Scanning Proton Therapy Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Z [Reading Hospital, West Reading, PA (United States); Gao, M [ProCure Treatment Centers, Warrenville, IL (United States)

    2014-06-01

    Purpose: Monte Carlo simulation plays an important role for proton Pencil Beam Scanning (PBS) technique. However, MC simulation demands high computing power and is limited to few large proton centers that can afford a computer cluster. We study the feasibility of utilizing cloud computing in the MC simulation of PBS beams. Methods: A GATE/GEANT4 based MC simulation software was installed on a commercial cloud computing virtual machine (Linux 64-bits, Amazon EC2). Single spot Integral Depth Dose (IDD) curves and in-air transverse profiles were used to tune the source parameters to simulate an IBA machine. With the use of StarCluster software developed at MIT, a Linux cluster with 2–100 nodes can be conveniently launched in the cloud. A proton PBS plan was then exported to the cloud where the MC simulation was run. Results: The simulated PBS plan has a field size of 10×10cm{sup 2}, 20cm range, 10cm modulation, and contains over 10,000 beam spots. EC2 instance type m1.medium was selected considering the CPU/memory requirement and 40 instances were used to form a Linux cluster. To minimize cost, master node was created with on-demand instance and worker nodes were created with spot-instance. The hourly cost for the 40-node cluster was $0.63 and the projected cost for a 100-node cluster was $1.41. Ten million events were simulated to plot PDD and profile, with each job containing 500k events. The simulation completed within 1 hour and an overall statistical uncertainty of < 2% was achieved. Good agreement between MC simulation and measurement was observed. Conclusion: Cloud computing is a cost-effective and easy to maintain platform to run proton PBS MC simulation. When proton MC packages such as GATE and TOPAS are combined with cloud computing, it will greatly facilitate the pursuing of PBS MC studies, especially for newly established proton centers or individual researchers.

  17. SU-E-T-314: The Application of Cloud Computing in Pencil Beam Scanning Proton Therapy Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Wang, Z; Gao, M

    2014-01-01

    Purpose: Monte Carlo simulation plays an important role for proton Pencil Beam Scanning (PBS) technique. However, MC simulation demands high computing power and is limited to few large proton centers that can afford a computer cluster. We study the feasibility of utilizing cloud computing in the MC simulation of PBS beams. Methods: A GATE/GEANT4 based MC simulation software was installed on a commercial cloud computing virtual machine (Linux 64-bits, Amazon EC2). Single spot Integral Depth Dose (IDD) curves and in-air transverse profiles were used to tune the source parameters to simulate an IBA machine. With the use of StarCluster software developed at MIT, a Linux cluster with 2–100 nodes can be conveniently launched in the cloud. A proton PBS plan was then exported to the cloud where the MC simulation was run. Results: The simulated PBS plan has a field size of 10×10cm 2 , 20cm range, 10cm modulation, and contains over 10,000 beam spots. EC2 instance type m1.medium was selected considering the CPU/memory requirement and 40 instances were used to form a Linux cluster. To minimize cost, master node was created with on-demand instance and worker nodes were created with spot-instance. The hourly cost for the 40-node cluster was $0.63 and the projected cost for a 100-node cluster was $1.41. Ten million events were simulated to plot PDD and profile, with each job containing 500k events. The simulation completed within 1 hour and an overall statistical uncertainty of < 2% was achieved. Good agreement between MC simulation and measurement was observed. Conclusion: Cloud computing is a cost-effective and easy to maintain platform to run proton PBS MC simulation. When proton MC packages such as GATE and TOPAS are combined with cloud computing, it will greatly facilitate the pursuing of PBS MC studies, especially for newly established proton centers or individual researchers

  18. Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans

    Energy Technology Data Exchange (ETDEWEB)

    Veldhoen, Simon [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); University Hospital Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Schoellchen, Maximilian; Hanken, H.; Precht, C.; Heiland, M. [University Medical Center Hamburg, Department of Oral- and Maxillofacial Surgery, Hamburg (Germany); Henes, F.O.; Adam, G.; Regier, M. [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schoen, G. [University Medical Center Hamburg, Department of Medical Biometry and Epidemiology, Hamburg (Germany); Nagel, H.D. [Science and Technology for Radiology, Buchholz (Germany); Schumacher, U. [University Medical Center Hamburg, Institute of Anatomy, Hamburg (Germany)

    2017-02-15

    To compare multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) regarding radiation, resolution, image noise, and image quality. CBCT and 256-MDCT were compared based on three scan protocols: Standard-dose (∼24 mGy), reduced-dose (∼9 mGy), and low-dose (∼4 mGy). MDCT images were acquired in standard- and high-resolution mode (HR-MDCT) and reconstructed using filtered back projection (FBP) and iterative reconstruction (IR). Spatial resolution in linepairs (lp) and objective image noise (OIN) were assessed using dedicated phantoms. Image quality was assessed in scans of 25 cadaver heads using a Likert scale. OIN was markedly higher in FBP-MDCT when compared to CBCT. IR lowered the OIN to comparable values in standard-mode MDCT only. CBCT provided a resolution of 13 lp/cm at standard-dose and 11 lp/cm at reduced-dose vs. 11 lp/cm and 10 lp/cm in HR-MDCT. Resolution of 10 lp/cm was observed for both devices using low-dose settings. Quality scores of MDCT and CBCT did not differ at standard-dose (CBCT, 3.4; MDCT, 3.3-3.5; p > 0.05). Using reduced- and low-dose protocols, CBCT was superior (reduced-dose, 3.2 vs. 2.8; low dose, 3.0 vs. 2.3; p < 0.001). Using the low-dose protocol, the assessed CBCT provided better objective and subjective image quality and equality in resolution. Similar image quality, but better resolution using CBCT was observed at higher exposure settings. (orig.)

  19. Control of Neutralization Process Using Soft Computing

    Directory of Open Access Journals (Sweden)

    G. Balasubramanian

    2008-03-01

    Full Text Available A novel model-based nonlinear control strategy is proposed using an experimental pH neutralization process. The control strategy involves a non linear neural network (NN model, in the context of internal model control (IMC. When integrated into the internal model control scheme, the resulting controller is shown to have favorable practical implications as well as superior performance. The designed model based online IMC controller was implemented to a laboratory scaled pH process in real time using dSPACE 1104 interface card. The responses of pH and acid flow rate shows good tracking for both the set point and load chances over the entire nonlinear region.

  20. The Ganil computer control system renewal

    International Nuclear Information System (INIS)

    David, L.; Lecorche, E.; Luong, T.T.; Ulrich, M.

    1990-01-01

    Since 1982 the GANIL heavy ion accelerator has been under the control of 16-bit minicomputers MITRA, programmable logic controllers and microprocessorized Camac controllers, structured into a partially centralized system. This control system has to be renewed to meet the increasing demands of the accelerator operation which aims to provide higher quality ion beams under more reliable conditions. This paper gives a brief description of the existing control system and then discusses the main issues of the design and the implementation of the future control system: distributed powerful processors federated through Ethernet and flexible network-wide database access, VME standard and front-end microprocessors, enhanced color graphic tools and workstation based operator interface

  1. Applying improved instrumentation and computer control systems

    International Nuclear Information System (INIS)

    Bevilacqua, F.; Myers, J.E.

    1977-01-01

    In-core and out-of-core instrumentation systems for the Cherokee-I reactor are described. The reactor has 61m-core instrument assemblies. Continuous computer monitoring and processing of data from over 300 fixed detectors will be used to improve the manoeuvering of core power. The plant protection system is a standard package for the Combustion Engineering System 80, consisting of two independent systems, the reactor protection system and the engineering safety features activation system, both of which are designed to meet NRC, ANS and IEEE design criteria or standards. The plants protection system has its own computer which provides plant monitoring, alarming, logging and performance calculations. (U.K.)

  2. Rotational control of computer generated holograms.

    Science.gov (United States)

    Preece, Daryl; Rubinsztein-Dunlop, Halina

    2017-11-15

    We develop a basis for three-dimensional rotation of arbitrary light fields created by computer generated holograms. By adding an extra phase function into the kinoform, any light field or holographic image can be tilted in the focal plane with minimized distortion. We present two different approaches to rotate an arbitrary hologram: the Scheimpflug method and a novel coordinate transformation method. Experimental results are presented to demonstrate the validity of both proposed methods.

  3. Computer-assisted evaluation of pulmonary emphysema in CT scans: comparison between a locally developed system and a freeware system

    International Nuclear Information System (INIS)

    Felix, John Hebert da Silva; Cortez, Paulo Cesar; Costa, Rodrigo Carvalho Sousa; Fortaleza, Simone Castelo Branco; Pereira, Eanes Delgado Barros; Holanda, Marcelo Alcantara

    2009-01-01

    Objective: to present a locally developed system of computer vision for use with HRCT images, designated SIStema para a Deteccao e a quantificacao de Enfisema Pulmonar (SISDEP, System to Detect and Quantify Pulmonary Emphysema), and to compare this system with a free ware system tool. Methods: thirty-three HRCT images scanned at the apex, hilum and base of the lungs of 11 patients with COPD were analyzed. The SISDEP was compared with the Osiris Medical Imaging Software Program regarding lung parenchyma segmentation, precision of the measurement of the cross-sectional area of the lungs in mm 2 , mean lung density (MLD), relative area (RA) of the lung occupied by voxels with attenuation values 2 = 0.99, 0.99, 0.99 and 1.00, respectively). The color mask tool of the SISDEP allowed excellent visualization of hyper inflated areas, discriminating them from normal areas. Conclusions: the SISDEP was efficient in segmenting the lungs and quantifying lung hyper inflation, presenting an excellent correlation with the Osiris system. The SISDEP constitutes a promising computational tool for diagnosing and assessing the progression of emphysema in HRCT images of COPD patients. (author)

  4. Self-mixing laser diode included in scanning microwave microscope to the control of probe nanodisplacement

    Science.gov (United States)

    Usanov, D. A.; Skripal, A. V.; Astakhov, E. I.; Dobdin, S. Y.

    2018-04-01

    The possibilities of self-mixing interferometry for measuring nanodisplacement of a probe included in a near-field scanning microwave microscope have been considered. The features of the formation of a laser interference signal at current modulation of the wavelength of laser radiation have been investigated. Experimental responses of a semiconductor laser system included in scanning microwave microscope to control nanodisplacement of the probe have been demonstrated.To register the nanodisplacement of the probe, it is proposed to use the method of determining the stationary phase of a laser interference signal by low-frequency spectrum of a semiconductor laser. The change of the amplitudes of the spectral components in the spectrum of the interference signal due to creation of the standing wave in the external resonator of the laser self-mixing system has been shown. The form of the interference signal at current modulation of the radiation wavelength was experimentally obtained when the probe moves with a step of 80 nm. The results of measuring nanodisplacements of an electromagnetic translator STANDA 8MVT40-13 have been demonstrated. Deviation of the nanodisplacement of the proposed method does not exceed 15%.

  5. LabVIEW control software for scanning micro-beam X-ray fluorescence spectrometer.

    Science.gov (United States)

    Wrobel, Pawel; Czyzycki, Mateusz; Furman, Leszek; Kolasinski, Krzysztof; Lankosz, Marek; Mrenca, Alina; Samek, Lucyna; Wegrzynek, Dariusz

    2012-05-15

    Confocal micro-beam X-ray fluorescence microscope was constructed. The system was assembled from commercially available components - a low power X-ray tube source, polycapillary X-ray optics and silicon drift detector - controlled by an in-house developed LabVIEW software. A video camera coupled to optical microscope was utilized to display the area excited by X-ray beam. The camera image calibration and scan area definition software were also based entirely on LabVIEW code. Presently, the main area of application of the newly constructed spectrometer is 2-dimensional mapping of element distribution in environmental, biological and geological samples with micrometer spatial resolution. The hardware and the developed software can already handle volumetric 3-D confocal scans. In this work, a front panel graphical user interface as well as communication protocols between hardware components were described. Two applications of the spectrometer, to homogeneity testing of titanium layers and to imaging of various types of grains in air particulate matter collected on membrane filters, were presented. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Towards practical control design using neural computation

    Science.gov (United States)

    Troudet, Terry; Garg, Sanjay; Mattern, Duane; Merrill, Walter

    1991-01-01

    The objective is to develop neural network based control design techniques which address the issue of performance/control effort tradeoff. Additionally, the control design needs to address the important issue if achieving adequate performance in the presence of actuator nonlinearities such as position and rate limits. These issues are discussed using the example of aircraft flight control. Given a set of pilot input commands, a feedforward net is trained to control the vehicle within the constraints imposed by the actuators. This is achieved by minimizing an objective function which is the sum of the tracking errors, control input rates and control input deflections. A tradeoff between tracking performance and control smoothness is obtained by varying, adaptively, the weights of the objective function. The neurocontroller performance is evaluated in the presence of actuator dynamics using a simulation of the vehicle. Appropriate selection of the different weights in the objective function resulted in the good tracking of the pilot commands and smooth neurocontrol. An extension of the neurocontroller design approach is proposed to enhance its practicality.

  7. Scalable quantum computation via local control of only two qubits

    International Nuclear Information System (INIS)

    Burgarth, Daniel; Maruyama, Koji; Murphy, Michael; Montangero, Simone; Calarco, Tommaso; Nori, Franco; Plenio, Martin B.

    2010-01-01

    We apply quantum control techniques to a long spin chain by acting only on two qubits at one of its ends, thereby implementing universal quantum computation by a combination of quantum gates on these qubits and indirect swap operations across the chain. It is shown that the control sequences can be computed and implemented efficiently. We discuss the application of these ideas to physical systems such as superconducting qubits in which full control of long chains is challenging.

  8. Role of optical computers in aeronautical control applications

    Science.gov (United States)

    Baumbick, R. J.

    1981-01-01

    The role that optical computers play in aircraft control is determined. The optical computer has the potential high speed capability required, especially for matrix/matrix operations. The optical computer also has the potential for handling nonlinear simulations in real time. They are also more compatible with fiber optic signal transmission. Optics also permit the use of passive sensors to measure process variables. No electrical energy need be supplied to the sensor. Complex interfacing between optical sensors and the optical computer is avoided if the optical sensor outputs can be directly processed by the optical computer.

  9. Scan Statistics

    CERN Document Server

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  10. Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations.

    Science.gov (United States)

    Shokri, Abbas; Eskandarloo, Amir; Norouzi, Marouf; Poorolajal, Jalal; Majidi, Gelareh; Aliyaly, Alireza

    2018-03-01

    This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

  11. Ku-Band Traveling Wave Slot Array Using Simple Scanning Control

    Science.gov (United States)

    Host, Nicholas K.; Chen, Chi-Chih; Volakis, John L.; Miranda, Felix A.

    2015-01-01

    This paper introduces a feeding concept aimed at simplifying the backend (phase shifters) of traditional phased arrays. As an alternative to traditional phased arrays, we employ a traveling wave array (TWA) using a single feedline whose propagation constant is controlled via a single, small mechanical movement without a need for phase shifters to enable scanning. Specifically, a dielectric plunger is positioned within a parallel plate waveguide (PPW) transmission line (TL) that feeds the TWA. By adjusting the position of the dielectric plunger within the PPW feeding the TWA, beam steering is achieved. A 20 element array is designed at 13GHz shown to give stable realized gain across the angular range of -25 deg. less than or equal to theta less than or equal to 25 deg. A proof of concept array is fabricated and measured to demonstrate and validate the concept's operation.

  12. Prototype of Remote Controlled Robot Vehicle to Scan Radioactive Contaminated Areas

    International Nuclear Information System (INIS)

    Ratongasoandrazana, J.B.; Raoelina Andriambololona; Rambolamanana, G.; Andrianiaina, H.; Rajaobelison, J.

    2016-01-01

    The ionizing radiations are not directly audible by the organs of sense of the human being. Maintenance and handling of sources of such ionizing radiations present some risks of very serious and often irreversible accident for human organism. The works of experimentation and maintenance in such zone also present the risks requiring some minimum of precaution. Thus, the main objective of this work is to design and develop (hard- and software) a prototype of educational semi-autonomous Radio Frequency controlled robot-vehicle based on 8-bit AVR-RISC Flash microcontroller system (ATmega128L) able to detect, identify and map the radioactive contaminated area. An integrated video camera coupled with a UHF video transmitter module, placed in front of the robot, will be used as visual feedback control to well direct it toward a precise place to reach. The navigation information and the data collected are transmitted from the robot toward the Computer via 02 Radio Frequency Transceivers for peer-to-peer serial data transfer in half-duplex mode. A Joystick module which is connected to the Computer parallel port allows full motion control of the platform. Robot-vehicle user interface program for the PC has been designed to allow full control of all functions of the robot vehicles.

  13. Computer control of the SMC polarized target

    International Nuclear Information System (INIS)

    Le Goff, J.M.; Azoulay, R.; Berglund, P.; Dulya, C.; Gournay, J.F.; Hayashi, N.; Kyynaeraeinen, J.; Magnon, A.; Niinikoski, T.O.; Trentalange, S.

    1995-01-01

    The SMC polarized target is controlled through VME crates driven by CPUs working under the VxWorks operating system. The CPUs are connected to a SUN workstation which provides the user interface due to a graphical package named SL-GMS. This results in user friendliness, high modularity and flexibility. The system allows the control of: (1) the superconductive solenoid and the transverse dipole: control of the power supplies; automatic reversal of the spin direction by field rotation; acquisition, display and storage of the electric and cryogenic parameters; generation of alarms; and (2) the dilution refrigerator: evaporator level control; acquisition, display and storage of ∼100 cryogenic parameters; and generation of alarms. ((orig.))

  14. Towards an Approach of Semantic Access Control for Cloud Computing

    Science.gov (United States)

    Hu, Luokai; Ying, Shi; Jia, Xiangyang; Zhao, Kai

    With the development of cloud computing, the mutual understandability among distributed Access Control Policies (ACPs) has become an important issue in the security field of cloud computing. Semantic Web technology provides the solution to semantic interoperability of heterogeneous applications. In this paper, we analysis existing access control methods and present a new Semantic Access Control Policy Language (SACPL) for describing ACPs in cloud computing environment. Access Control Oriented Ontology System (ACOOS) is designed as the semantic basis of SACPL. Ontology-based SACPL language can effectively solve the interoperability issue of distributed ACPs. This study enriches the research that the semantic web technology is applied in the field of security, and provides a new way of thinking of access control in cloud computing.

  15. Newly defined landmarks for a three-dimensionally based cephalometric analysis: a retrospective cone-beam computed tomography scan review.

    Science.gov (United States)

    Lee, Moonyoung; Kanavakis, Georgios; Miner, R Matthew

    2015-01-01

    To identify two novel three-dimensional (3D) cephalometric landmarks and create a novel three-dimensionally based anteroposterior skeletal measurement that can be compared with traditional two-dimensional (2D) cephalometric measurements in patients with Class I and Class II skeletal patterns. Full head cone-beam computed tomography (CBCT) scans of 100 patients with all first molars in occlusion were obtained from a private practice. InvivoDental 3D (version 5.1.6, Anatomage, San Jose, Calif) was used to analyze the CBCT scans in the sagittal and axial planes to create new landmarks and a linear 3D analysis (M measurement) based on maxillary and mandibular centroids. Independent samples t-test was used to compare the mean M measurement to traditional 2D cephalometric measurements, ANB and APDI. Interexaminer and intraexaminer reliability were evaluated using 2D and 3D scatterplots. The M measurement, ANB, and APDI could statistically differentiate between patients with Class I and Class II skeletal patterns (P < .001). The M measurement exhibited a correlation coefficient (r) of -0.79 and 0.88 with APDI and ANB, respectively. The overall centroid landmarks and the M measurement combine 2D and 3D methods of imaging; the measurement itself can distinguish between patients with Class I and Class II skeletal patterns and can serve as a potential substitute for ANB and APDI. The new three-dimensionally based landmarks and measurements are reliable, and there is great potential for future use of 3D analyses for diagnosis and research.

  16. Prevalence and diagnostic performance of computed tomography angiography spot sign for intracerebral hematoma expansion depend on scan timing

    Energy Technology Data Exchange (ETDEWEB)

    Tsukabe, Akio; Watanabe, Yoshiyuki; Tanaka, Hisashi; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Yoshiya, Kazuhisa; Shimazu, Takeshi [Osaka University Graduate School of Medicine, Department of Traumatology and Acute Critical Medicine, Suita, Osaka (Japan)

    2014-12-15

    The computed tomography angiography (CTA) spot sign correlates with intracerebral hemorrhage (ICH) expansion; however, various diagnostic performances for hematoma expansion, especially in sensitivity, have been reported. We aimed to assess the impact of scan timing of CTA on the diagnostic performance of the CTA spot sign for ICH expansion in two different arterial phases within patients. Eighty-three consecutive patients with primary ICH who received two sequential CTAs were recruited. Two neuroradiologists reviewed CTAs for CTA spot signs, while one reviewed initial and follow-up non-contrast CT for measuring ICH volume. The time interval between two phases was then calculated, and the diagnostic performance of CTA spot sign in each phase was evaluated. CTA spot signs were observed in 20/83 (24.1 %) patients in the early phase and 44/83 (53.0 %) patients in the late phase. The mean time interval between the two phases was 12.7 s. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for hematoma progression of CTA spot sign were 48.1, 87.5, 65.0, 77.8, and 74.7 %, respectively, in early phase and 92.6, 66.1, 56.8, 94.9, and 74.7 %, respectively, in late phase. The CTA spot sign was significantly associated with ICH expansion in early (P < 0.001) and late (P < 0.00001) phases (Pearson's chi-square test). A mere 10-s difference in scan timing could make a difference on prevalence and diagnostic performance of the CTA spot sign, suggesting a need for the standardization of the CTA protocol to generalize the approach for effective clinical application. (orig.)

  17. The Dark Side of Computer-Mediated Control

    DEFF Research Database (Denmark)

    Cunha, J. V.; Carugati, Andrea; Leclercq, A.

    2015-01-01

    of computer-mediated control when work and its electronic representation are loosely coupled, because it is employees who report their work in IT systems. Data from a 15-month ethnographic study of the appropriation of a customer relationship management system in the sales department of a large organization......Research on the dark side of computer-mediated control has explained the consequences of computer-mediated control when work is tightly coupled with its electronic representation because information systems record work automatically. Our study complements prior research by addressing the dark side...

  18. Digital control computer upgrade at the Cernavoda NPP simulator

    International Nuclear Information System (INIS)

    Ionescu, T.

    2006-01-01

    The Plant Process Computer equips some Nuclear Power Plants, like CANDU-600, with Centralized Control performed by an assembly of two computers known as Digital Control Computers (DCC) and working in parallel for safely driving of the plan at steady state and during normal maneuvers but also during abnormal transients when the plant is automatically steered to a safe state. The Centralized Control means both hardware and software with obligatory presence in the frame of the Full Scope Simulator and subject to changing its configuration with specific requirements during the plant and simulator life and covered by this subsection

  19. A computer program for controlling a university radioactive material inventory: From confusion to computer to control

    International Nuclear Information System (INIS)

    Robb, D.B.; Riches, C.G.; O'Brian, M.J.; Riordan, F.J.

    1984-01-01

    The University of Washington is a large user of radioactive material. Over 250 authorized programs are working in over 600 labs with nearly 3500 orders of radioactive material per year. The state license sets limits on the total amount of material on campus. There are also limits on sewer disposal. To meet these needs it is necessary to know the amount of material on campus at any time. A computer program was developed which covered many aspects of the radiation safety record needs including inventory control. Inventory is now managed by tracking each order from purchase to disposal. A screen menu as part of the interactive program allows immediate and detailed information about the inventory at time of purchase approval and delivery. Because of this system our knowledge and control of radionuclide work on campus has increased dramatically. A description of how this system is used during ordering, delivery and disposal will be given. Details on the methods to check limits are included along with a summary of the reports made possible by the current data files

  20. Complex system modelling and control through intelligent soft computations

    CERN Document Server

    Azar, Ahmad

    2015-01-01

    The book offers a snapshot of the theories and applications of soft computing in the area of complex systems modeling and control. It presents the most important findings discussed during the 5th International Conference on Modelling, Identification and Control, held in Cairo, from August 31-September 2, 2013. The book consists of twenty-nine selected contributions, which have been thoroughly reviewed and extended before their inclusion in the volume. The different chapters, written by active researchers in the field, report on both current theories and important applications of soft-computing. Besides providing the readers with soft-computing fundamentals, and soft-computing based inductive methodologies/algorithms, the book also discusses key industrial soft-computing applications, as well as multidisciplinary solutions developed for a variety of purposes, like windup control, waste management, security issues, biomedical applications and many others. It is a perfect reference guide for graduate students, r...

  1. Advances in soft computing, intelligent robotics and control

    CERN Document Server

    Fullér, Robert

    2014-01-01

    Soft computing, intelligent robotics and control are in the core interest of contemporary engineering. Essential characteristics of soft computing methods are the ability to handle vague information, to apply human-like reasoning, their learning capability, and ease of application. Soft computing techniques are widely applied in the control of dynamic systems, including mobile robots. The present volume is a collection of 20 chapters written by respectable experts of the fields, addressing various theoretical and practical aspects in soft computing, intelligent robotics and control. The first part of the book concerns with issues of intelligent robotics, including robust xed point transformation design, experimental verification of the input-output feedback linearization of differentially driven mobile robot and applying kinematic synthesis to micro electro-mechanical systems design. The second part of the book is devoted to fundamental aspects of soft computing. This includes practical aspects of fuzzy rule ...

  2. Computed Tomography Scanning Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION:Advances research in the areas of marine geosciences, geotechnical, civil, and chemical engineering, physics, and ocean acoustics by using high-resolution,...

  3. Computer-controlled system for plasma ion energy auto-analyzer

    International Nuclear Information System (INIS)

    Wu Xianqiu; Chen Junfang; Jiang Zhenmei; Zhong Qinghua; Xiong Yuying; Wu Kaihua

    2003-01-01

    A computer-controlled system for plasma ion energy auto-analyzer was technically studied for rapid and online measurement of plasma ion energy distribution. The system intelligently controls all the equipments via a RS-232 port, a printer port and a home-built circuit. The software designed by LabVIEW G language automatically fulfils all of the tasks such as system initializing, adjustment of scanning-voltage, measurement of weak-current, data processing, graphic export, etc. By using the system, a few minutes are taken to acquire the whole ion energy distribution, which rapidly provide important parameters of plasma process techniques based on semiconductor devices and microelectronics

  4. Intelligent computational control of multi-fingered dexterous robotic hand

    OpenAIRE

    Chen, Disi; Li, Gongfa; Jiang, Guozhang; Fang, Yinfeng; Ju, Zhaojie; Liu, Honghai

    2015-01-01

    We discuss the intelligent computational control theory and introduce the hardware structure of HIT/DLR II dexterous robotic hand, which is the typical dexterous robotic hand. We show that how DSP or FPGA controller can be used in the dexterous robotic hand. A popular intelligent dexterous robotic hand control system, which named Electromyography (EMG) control is investigated. We introduced some mathematical algorithms in EMG controlling, such as Gauss mixture model (GMM), artificial neural n...

  5. Computer controls for the WITCH experiment

    Czech Academy of Sciences Publication Activity Database

    Tandecki, M.; Beck, M.; Beck, D.; Brand, H.; Breitenfeldt, M.; De Leebeeck, V.; Friedag, P.; Herlert, A.; Kozlov, V.; Mader, J.; Roccia, S.; Soti, G.; Traykov, E.; Van Gorp, S.; Wauters, F.; Weinheimer, C.; Zákoucký, Dalibor; Severijns, N.

    2011-01-01

    Roč. 629, č. 1 (2011), s. 369-405 ISSN 0168-9002 R&D Projects: GA MŠk LA08015 Institutional research plan: CEZ:AV0Z10480505; CEZ:AV0Z10100523 Keywords : LabVIEW * Control system * Distributed programming Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.207, year: 2011

  6. Control rod computer code IAMCOS: general theory and numerical methods

    International Nuclear Information System (INIS)

    West, G.

    1982-11-01

    IAMCOS is a computer code for the description of mechanical and thermal behavior of cylindrical control rods for fast breeders. This code version was applied, tested and modified from 1979 to 1981. In this report are described the basic model (02 version), theoretical definitions and computation methods [fr

  7. Software For Computer-Aided Design Of Control Systems

    Science.gov (United States)

    Wette, Matthew

    1994-01-01

    Computer Aided Engineering System (CAESY) software developed to provide means to evaluate methods for dealing with users' needs in computer-aided design of control systems. Interpreter program for performing engineering calculations. Incorporates features of both Ada and MATLAB. Designed to be flexible and powerful. Includes internally defined functions, procedures and provides for definition of functions and procedures by user. Written in C language.

  8. Controller for computer control of brushless dc motors. [automobile engines

    Science.gov (United States)

    Hieda, L. S. (Inventor)

    1981-01-01

    A motor speed and torque controller for brushless d.c. motors provides an unusually smooth torque control arrangement. The controller provides a means for controlling a current waveform in each winding of a brushless dc motor by synchronization of an excitation pulse train from a programmable oscillator. Sensing of torque for synchronization is provided by a light beam chopper mounted on the motor rotor shaft. Speed and duty cycle are independently controlled by controlling the frequency and pulse width output of the programmable oscillator. A means is also provided so that current transitions from one motor winding to another is effected without abrupt changes in output torque.

  9. Emergency Flight Control Using Computer-Controlled Thrust

    Science.gov (United States)

    Burcham, Frank W., Jr.; Fullerton, C. Gordon; Stewart, James F.; Gilyard, Glenn B.; Conley, Joseph A.

    1995-01-01

    Propulsion Controlled Aircraft (PCA) systems are digital electronic control systems undergoing development to provide limited maneuvering ability through variations of individual engine thrusts in multiple-engine airplanes. Provide landing capability when control surfaces inoperable. Incorporated on existing and future airplanes that include digital engine controls, digital flight controls, and digital data buses, adding no weight for additional hardware to airplane. Possible to handle total failure of hydraulic system, depending on how surfaces respond to loss of hydraulic pressure, and broken control cables or linkages. Future airplanes incorporate data from Global Positioning System for guidance to any suitable emergency runway in world.

  10. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    Science.gov (United States)

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (ptime of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Usefulness of the Bolus-Tracking Baseline Scan for the Diagnosis of Hepatic Steatosis in Abdominal Computed Tomography: A Feasibility Study

    International Nuclear Information System (INIS)

    Gossner, J.; Schäfer, S.

    2013-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a common pathology in western societies. Unenhanced computed tomography (CT) of the liver is a valuable tool in determining the presence of steatosis hepatis, but in most departments standard CT protocols of abdomen often do not include unenhanced scans anymore. In a small series of 22 patients the liver density was measured in the acquired low-dose baseline scan for bolus tracking and was compared to the measurement in a regular unenhanced CT scan of the upper abdomen. The mean difference between the unenhanced CT scan and the low-dose baseline scan was 3.4 HU (range 0.2–8.6 HU); the difference between these two scans was 5 HU or smaller in 82% of the patients. There was a significant difference between the two used CT scanners; this has to be kept in mind before implementing this approach into daily practice. All but one patient with fatty liver disease on unenhanced CT were diagnosed using the baseline scan. The baseline scan for bolus tracking may be useful for the diagnosis or in the followup of fatty liver disease

  12. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    Directory of Open Access Journals (Sweden)

    Paoli Alessandro

    2011-02-01

    Full Text Available Abstract Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast and preoperative (radiographic template models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology.

  13. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    Science.gov (United States)

    2011-01-01

    Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504

  14. Decoherence control in quantum computing with simple chirped ...

    Indian Academy of Sciences (India)

    strate this with selective control of decoherence for a multilevel system with a simple ... The concept of quantum computer (QC) has attracted considerable attention ... as intramolecular vibrational relaxation (IVR), which is the most important ...

  15. Integrated evolutionary computation neural network quality controller for automated systems

    Energy Technology Data Exchange (ETDEWEB)

    Patro, S.; Kolarik, W.J. [Texas Tech Univ., Lubbock, TX (United States). Dept. of Industrial Engineering

    1999-06-01

    With increasing competition in the global market, more and more stringent quality standards and specifications are being demands at lower costs. Manufacturing applications of computing power are becoming more common. The application of neural networks to identification and control of dynamic processes has been discussed. The limitations of using neural networks for control purposes has been pointed out and a different technique, evolutionary computation, has been discussed. The results of identifying and controlling an unstable, dynamic process using evolutionary computation methods has been presented. A framework for an integrated system, using both neural networks and evolutionary computation, has been proposed to identify the process and then control the product quality, in a dynamic, multivariable system, in real-time.

  16. Air Traffic Control: Weak Computer Security Practices Jeopardize Flight Safety

    Science.gov (United States)

    1998-05-01

    Given the paramount importance of computer security of Air Traffic Control (ATC) systems, Congress asked the General Accounting Office to determine (1) whether the Fedcral Aviation Administration (FAA) is effectively managing physical security at ATC...

  17. Computation of reactor control rod drop time under accident conditions

    International Nuclear Information System (INIS)

    Dou Yikang; Yao Weida; Yang Renan; Jiang Nanyan

    1998-01-01

    The computational method of reactor control rod drop time under accident conditions lies mainly in establishing forced vibration equations for the components under action of outside forces on control rod driven line and motion equation for the control rod moving in vertical direction. The above two kinds of equations are connected by considering the impact effects between control rod and its outside components. Finite difference method is adopted to make discretization of the vibration equations and Wilson-θ method is applied to deal with the time history problem. The non-linearity caused by impact is iteratively treated with modified Newton method. Some experimental results are used to validate the validity and reliability of the computational method. Theoretical and experimental testing problems show that the computer program based on the computational method is applicable and reliable. The program can act as an effective tool of design by analysis and safety analysis for the relevant components

  18. ANS main control complex three-dimensional computer model development

    International Nuclear Information System (INIS)

    Cleaves, J.E.; Fletcher, W.M.

    1993-01-01

    A three-dimensional (3-D) computer model of the Advanced Neutron Source (ANS) main control complex is being developed. The main control complex includes the main control room, the technical support center, the materials irradiation control room, computer equipment rooms, communications equipment rooms, cable-spreading rooms, and some support offices and breakroom facilities. The model will be used to provide facility designers and operations personnel with capabilities for fit-up/interference analysis, visual ''walk-throughs'' for optimizing maintain-ability, and human factors and operability analyses. It will be used to determine performance design characteristics, to generate construction drawings, and to integrate control room layout, equipment mounting, grounding equipment, electrical cabling, and utility services into ANS building designs. This paper describes the development of the initial phase of the 3-D computer model for the ANS main control complex and plans for its development and use

  19. Computer controlled motor vehicle battery circuit

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, W.R.; McAuiliffe, G.N.; Schlageter, G.A.

    1986-04-01

    This patent consists of a motor vehicle having a DC motor, a pedal biased to a released position and depressed by the driver to increase speed. An alternate switching means affects the vehicle speed control, a foot switch is operated by the pedal and operative when the pedal is depressed to close a circuit enabling energization of the alternate switching means. A microprocessor includes a program for controlling operation of the alternate switching means, the foot switch is operative when the pedal is released to open the enabling circuit. The program includes a register which is incremented with each passage of the logic and is responsive to the incremented count in the register to instruct a change in position of the alternate switching means.

  20. Computer control of pulsed tunable dye lasers

    International Nuclear Information System (INIS)

    Thattey, S.S.; Dongare, A.S.; Suri, B.M.; Nair, L.G.

    1992-01-01

    Pulsed tunable dye lasers are being used extensively for spectroscopic and photo-chemical experiments, and a system for acquisition and spectral analysis of a volume of data generated will be quite useful. The development of a system for wavelength tuning and control of tunable dye lasers and an acquisition system for spectral data generated in experiments with these lasers are described. With this system, it is possible to control the tuning of three lasers, and acquire data in four channels, simultaneously. It is possible to arrive at the desired dye laser wavelength with a reproducibility of ± 0.012 cm -1 , which is within the absorption width (atomic interaction) caused by pulsed dye lasers of linewidth 0.08 cm -1 . The spectroscopic data generated can be analyzed for spectral identification within absolute accuracy ± 0.012 cm -1 . (author). 6 refs., 11 figs

  1. Predictive access control for distributed computation

    DEFF Research Database (Denmark)

    Yang, Fan; Hankin, Chris; Nielson, Flemming

    2013-01-01

    We show how to use aspect-oriented programming to separate security and trust issues from the logical design of mobile, distributed systems. The main challenge is how to enforce various types of security policies, in particular predictive access control policies — policies based on the future beh...... behavior of a program. A novel feature of our approach is that we can define policies concerning secondary use of data....

  2. Real time computer controlled weld skate

    Science.gov (United States)

    Wall, W. A., Jr.

    1977-01-01

    A real time, adaptive control, automatic welding system was developed. This system utilizes the general case geometrical relationships between a weldment and a weld skate to precisely maintain constant weld speed and torch angle along a contoured workplace. The system is compatible with the gas tungsten arc weld process or can be adapted to other weld processes. Heli-arc cutting and machine tool routing operations are possible applications.

  3. Distributed computer control systems in future nuclear power plants

    International Nuclear Information System (INIS)

    Yan, G.; L'Archeveque, J.V.R.; Watkins, L.M.

    1978-09-01

    Good operating experience with computer control in CANDU reactors over the last decade justifies a broadening of the role of digital electronic and computer related technologies in future plants. Functions of electronic systems in the total plant context are reappraised to help evolve an appropriate match between technology and future applications. The systems research, development and demonstration program at CRNL is described, focusing on the projects pertinent to the real-time data acquisition and process control requirements. (author)

  4. Computer-integrated electric-arc melting process control system

    OpenAIRE

    Дёмин, Дмитрий Александрович

    2014-01-01

    Developing common principles of completing melting process automation systems with hardware and creating on their basis rational choices of computer- integrated electricarc melting control systems is an actual task since it allows a comprehensive approach to the issue of modernizing melting sites of workshops. This approach allows to form the computer-integrated electric-arc furnace control system as part of a queuing system “electric-arc furnace - foundry conveyor” and consider, when taking ...

  5. Virtual reality visual feedback for hand-controlled scanning probe microscopy manipulation of single molecules

    Directory of Open Access Journals (Sweden)

    Philipp Leinen

    2015-11-01

    Full Text Available Controlled manipulation of single molecules is an important step towards the fabrication of single molecule devices and nanoscale molecular machines. Currently, scanning probe microscopy (SPM is the only technique that facilitates direct imaging and manipulations of nanometer-sized molecular compounds on surfaces. The technique of hand-controlled manipulation (HCM introduced recently in Beilstein J. Nanotechnol. 2014, 5, 1926–1932 simplifies the identification of successful manipulation protocols in situations when the interaction pattern of the manipulated molecule with its environment is not fully known. Here we present a further technical development that substantially improves the effectiveness of HCM. By adding Oculus Rift virtual reality goggles to our HCM set-up we provide the experimentalist with 3D visual feedback that displays the currently executed trajectory and the position of the SPM tip during manipulation in real time, while simultaneously plotting the experimentally measured frequency shift (Δf of the non-contact atomic force microscope (NC-AFM tuning fork sensor as well as the magnitude of the electric current (I flowing between the tip and the surface. The advantages of the set-up are demonstrated by applying it to the model problem of the extraction of an individual PTCDA molecule from its hydrogen-bonded monolayer grown on Ag(111 surface.

  6. Design and Implementation of a Mechanical Control System for the Scanning Microwave Limb Sounder

    Science.gov (United States)

    Bowden, William

    2011-01-01

    The Scanning Microwave Limb Sounder (SMLS) will use technological improvements in low noise mixers to provide precise data on the Earth's atmospheric composition with high spatial resolution. This project focuses on the design and implementation of a real time control system needed for airborne engineering tests of the SMLS. The system must coordinate the actuation of optical components using four motors with encoder readback, while collecting synchronized telemetric data from a GPS receiver and 3-axis gyrometric system. A graphical user interface for testing the control system was also designed using Python. Although the system could have been implemented with a FPGA-based setup, we chose to use a low cost processor development kit manufactured by XMOS. The XMOS architecture allows parallel execution of multiple tasks on separate threads-making it ideal for this application and is easily programmed using XC (a subset of C). The necessary communication interfaces were implemented in software, including Ethernet, with significant cost and time reduction compared to an FPGA-based approach. For these reasons, the XMOS technology is an attractive, cost effective, alternative to FPGA-based technologies for this design and similar rapid prototyping projects.

  7. Virtual reality visual feedback for hand-controlled scanning probe microscopy manipulation of single molecules.

    Science.gov (United States)

    Leinen, Philipp; Green, Matthew F B; Esat, Taner; Wagner, Christian; Tautz, F Stefan; Temirov, Ruslan

    2015-01-01

    Controlled manipulation of single molecules is an important step towards the fabrication of single molecule devices and nanoscale molecular machines. Currently, scanning probe microscopy (SPM) is the only technique that facilitates direct imaging and manipulations of nanometer-sized molecular compounds on surfaces. The technique of hand-controlled manipulation (HCM) introduced recently in Beilstein J. Nanotechnol. 2014, 5, 1926-1932 simplifies the identification of successful manipulation protocols in situations when the interaction pattern of the manipulated molecule with its environment is not fully known. Here we present a further technical development that substantially improves the effectiveness of HCM. By adding Oculus Rift virtual reality goggles to our HCM set-up we provide the experimentalist with 3D visual feedback that displays the currently executed trajectory and the position of the SPM tip during manipulation in real time, while simultaneously plotting the experimentally measured frequency shift (Δf) of the non-contact atomic force microscope (NC-AFM) tuning fork sensor as well as the magnitude of the electric current (I) flowing between the tip and the surface. The advantages of the set-up are demonstrated by applying it to the model problem of the extraction of an individual PTCDA molecule from its hydrogen-bonded monolayer grown on Ag(111) surface.

  8. An Annotated and Cross-Referenced Bibliography on Computer Security and Access Control in Computer Systems.

    Science.gov (United States)

    Bergart, Jeffrey G.; And Others

    This paper represents a careful study of published works on computer security and access control in computer systems. The study includes a selective annotated bibliography of some eighty-five important published results in the field and, based on these papers, analyzes the state of the art. In annotating these works, the authors try to be…

  9. Diagnostic accuracy of full-body linear X-ray scanning in multiple trauma patients in comparison to computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Joeres, A.P.W.; Heverhagen, J.T.; Bonel, H. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Exadaktylos, A. [Inselspital - University Hospital Bern (Switzerland). Dept. of Emergency Medicine; Klink, T. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Wuerzburg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology

    2016-02-15

    The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. The overall sensitivity of LS was 49.2%, the specificity was 93.3%, the positive predictive value was 91%, and the negative predictive value was 57.5%. The overall sensitivity for vertebral fractures was 16.7%, and the specificity was 100%. The sensitivity was 48.7% and the specificity 98.2% for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS.40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT.

  10. How do trees grow? Response from the graphical and quantitative analyses of computed tomography scanning data collected on stem sections.

    Science.gov (United States)

    Dutilleul, Pierre; Han, Li Wen; Beaulieu, Jean

    2014-06-01

    Tree growth, as measured via the width of annual rings, is used for environmental impact assessment and climate back-forecasting. This fascinating natural process has been studied at various scales in the stem (from cell and fiber within a growth ring, to ring and entire stem) in one, two, and three dimensions. A new approach is presented to study tree growth in 3D from stem sections, at a scale sufficiently small to allow the delineation of reliable limits for annual rings and large enough to capture directional variation in growth rates. The technology applied is computed tomography scanning, which provides - for one stem section - millions of data (indirect measures of wood density) that can be mapped, together with a companion measure of dispersion and growth ring limits in filigree. Graphical and quantitative analyses are reported for white spruce trees with circular vs non-circular growth. Implications for dendroclimatological research are discussed. Copyright © 2014 Académie des sciences. Published by Elsevier SAS. All rights reserved.

  11. Non-Contrast Computed Tomography Scan Based Parameters of Ureteric Stones Affecting the Outcome of Extracorporeal Shock Wave Lithotripsy

    Science.gov (United States)

    Ayaz Khan, Mohammad; Waqas Iqbal, Muhammad; Akbar, Mian Khalid; Saqib, Imad-ud-din; Akhter, Saeed

    2017-01-01

    Objective  To compare the non-contrast computed tomography (NCCT) scan-based parameters of ureteric stones affecting the outcome of extracorporeal shock wave lithotripsy (ESWL). Materials and methods We retrospectively evaluated the pre-procedure NCCT of 74 patients who had ESWL for solitary ureteric calculi of 5-20 mm in diameter. We assessed the age, sex, basal metabolic index (BMI), laterality, location, presence of double 'J' (DJ) stent, skin to stone distance (SSD), stone maximum diameter, Hounsfield unit (HU), Hounsfield density (HD), area, and volume. All those who had no stone on follow-up imaging within 30 days were declared successful while those who had residual stone were declared failures. Results The overall success rate was 78% (58/74). Sixty (81.1%) patients were male. The success of ESWL was correlated with lower SSD, Hounsfield units (HU) and Hounsfield density (HD). However, in multivariate analysis, SSD, Hounsfield unit, and stone area showed correlation with success of procedure but Hounsfield density failed to show correlation. The success rate in patients with stone HU 1000 were 93.9%, 69%, and 58.3%, respectively. Patients with lower BMI (30 kg/m2) and higher HD (>76 HU/mm). Conclusion BMI, SSD, stone Hounsfield units and Hounsfield unit density were strong predictors of outcome of ESWL for ureteric stone. PMID:28589076

  12. Hardware replacements and software tools for digital control computers

    International Nuclear Information System (INIS)

    Walker, R.A.P.; Wang, B-C.; Fung, J.

    1996-01-01

    Technological obsolescence is an on-going challenge for all computer use. By design, and to some extent good fortune, AECL has had a good track record with respect to the march of obsolescence in CANDU digital control computer technology. Recognizing obsolescence as a fact of life, AECL has undertaken a program of supporting the digital control technology of existing CANDU plants. Other AECL groups are developing complete replacement systems for the digital control computers, and more advanced systems for the digital control computers of the future CANDU reactors. This paper presents the results of the efforts of AECL's DCC service support group to replace obsolete digital control computer and related components and to provide friendlier software technology related to the maintenance and use of digital control computers in CANDU. These efforts are expected to extend the current lifespan of existing digital control computers through their mandated life. This group applied two simple rules; the product, whether new or replacement should have a generic basis, and the products should be applicable to both existing CANDU plants and to 'repeat' plant designs built using current design guidelines. While some exceptions do apply, the rules have been met. The generic requirement dictates that the product should not be dependent on any brand technology, and should back-fit to and interface with any such technology which remains in the control design. The application requirement dictates that the product should have universal use and be user friendly to the greatest extent possible. Furthermore, both requirements were designed to anticipate user involvement, modifications and alternate user defined applications. The replacements for hardware components such as paper tape reader/punch, moving arm disk, contact scanner and Ramtek are discussed. The development of these hardware replacements coincide with the development of a gateway system for selected CANDU digital control

  13. A Control and Detecting System of Micro-Near-Infrared Spectrometer Based on a MOEMS Scanning Grating Mirror

    Directory of Open Access Journals (Sweden)

    Haitao Liu

    2018-03-01

    Full Text Available Based on the scanning grating mirror we developed, this paper presents a method of the precise control of a scanning grating mirror and of high-speed spectrum data detection. In addition, the system circuit of the scanning grating mirror control and spectrum signal detecting is designed and manufactured in this paper. The mirror control system includes a drive generator module, an amplitude detection module, a feedback control module, and a variable gain amplification (VGA module; the detecting system includes a field programmable gate array (FPGA main control module, a synchronous trigger module, an analog-digital conversion (ADC module, and a universal serial bus (USB interface module. The final results of the experiment show that the control system has successfully realized the precision control of the swing of the scanning grating mirror and that the detecting system has successfully realized the high-speed acquisition and transmission of the spectral signal and the angle signals. The spectrum has been reconstructed according to the mathematical relationship between the wavelength λ and the angle β of the mirror. The resolution of the spectrometer reaches 10 nm in the wavelength range of 800–1800 nm, the signal-to-noise ratio (SNR of the spectrometer is 4562 at full scale, the spectrum data drift is 0.9% in 24 h, and the precision of the closed loop control is 0.06%.

  14. Measuring the quality of infection control in Dutch nursing homes using a standardized method; the Infection prevention RIsk Scan (IRIS)

    NARCIS (Netherlands)

    Willemsen, I.; Nelson-Melching, J.; Hendriks, Y.; Mulders, A.; Verhoeff, S.; Kluytmans-Vandenbergh, M.; Kluytmans, J.

    2014-01-01

    BACKGROUND: We developed a standardised method to assess the quality of infection control in Dutch Nursing Home (NH), based on a cross-sectional survey that visualises the results. The method was called the Infection control RIsk Infection Scan (IRIS). We tested the applicability of this new tool in

  15. Control mechanism of double-rotator-structure ternary optical computer

    Science.gov (United States)

    Kai, SONG; Liping, YAN

    2017-03-01

    Double-rotator-structure ternary optical processor (DRSTOP) has two characteristics, namely, giant data-bits parallel computing and reconfigurable processor, which can handle thousands of data bits in parallel, and can run much faster than computers and other optical computer systems so far. In order to put DRSTOP into practical application, this paper established a series of methods, namely, task classification method, data-bits allocation method, control information generation method, control information formatting and sending method, and decoded results obtaining method and so on. These methods form the control mechanism of DRSTOP. This control mechanism makes DRSTOP become an automated computing platform. Compared with the traditional calculation tools, DRSTOP computing platform can ease the contradiction between high energy consumption and big data computing due to greatly reducing the cost of communications and I/O. Finally, the paper designed a set of experiments for DRSTOP control mechanism to verify its feasibility and correctness. Experimental results showed that the control mechanism is correct, feasible and efficient.

  16. Computer controlled multi-leaf conformation radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, T [Tokyo Metropolitan Komagome Hospital (Japan); Inamura, K

    1981-10-01

    A conformation radiotherapy system with 5-split collimators of which openings can be controlled symmetrically by computerized techniques during rotational irradiation by a linear accelerator has been developed. Outline of the system performance and its clinical applications are described as follows. 1. Profile of the system: The hardware is composed of three parts, namely, the multi-split collimator, the electronic data processor, and the interface between those two parts. 1) The multi-leaf collimator is composed of 5 pairs (10 leaves) diaphragms. It can be mounted to the X-ray head of a linear accelerator when used, and can be dismounted after its use. 2) The electronic data processor sends control signal to the collimator according to the 5-leaf target volume data which can be stored into a minifloppy disc through the curve digitizer previously. This part is composed of a) dedicated micro processor, b) I/O expansion unit, c) color CRT display with key board, d) dual mini-floppy disc unit, e) curve digitizer and f) digital plotter for recording and verification of resulted accuracy. 2. Performance of the system: 1) Maximum field size: 15 cm x 15 cm at isocenter. 2) Maximum elongation ratio of the target volume: 3 : 1 when the longer diameter is 15 cm. 3) Control accuracy: Within +-3 mm deviation from planned beam focus at isocenter. 3. Clinical application: The method of treatment planning and clinical advantages of this irradiation method are explained by raising clinical experiences such as treating brain tumor and rectal cancer.

  17. Computer controlled multi-leaf conformation radiotherapy

    International Nuclear Information System (INIS)

    Matsuda, Tadayoshi; Inamura, Kiyonari.

    1981-01-01

    A conformation radiotherapy system with 5-split collimators of which openings can be controlled symmetrically by computerized techniques during rotational irradiation by a linear accelerator has been developed. Outline of the system performance and its clinical applications are described as follows. 1. Profile of the system: The hardware is composed of three parts, namely, the multi-split collimator, the electronic data processor, and the interface between those two parts. 1) The multi-leaf collimator is composed of 5 pairs (10 leaves) diaphragms. It can be mounted to the X-ray head of a linear accelerator when used, and can be dismounted after its use. 2) The electronic data processor sends control signal to the collimator according to the 5-leaf target volume data which can be stored into a minifloppy disc through the curve digitizer previously. This part is composed of a) dedicated micro processor, b) I/O expansion unit, c) color CRT display with key board, d) dual mini-floppy disc unit, e) curve digitizer and f) digital plotter for recording and verification of resulted accuracy. 2. Performance of the system: 1) Maximum field size: 15 cm x 15 cm at isocenter. 2) Maximum elongation ratio of the target volume: 3 : 1 when the longer diameter is 15 cm. 3) Control accuracy: Within +-3 mm deviation from planned beam focus at isocenter. 3. Clinical application: The method of treatment planning and clinical advantages of this irradiation method are explained by raising clinical experiences such as treating brain tumor and rectal cancer. (author)

  18. Computer systems for the control of teletherapy units

    International Nuclear Information System (INIS)

    Brace, J.A.

    1985-01-01

    This paper describes a computer-controlled tracking cobalt unit installed at the Royal Free Hospital. It is based on a standard TEM MS90 unit and operates at 90-cm source-axis distance with a geometric field size of 45 x 45 cm at that distance. It has been modified so that it can be used either manually or under computer control. There are nine parameters that can be controlled positionally and two that can be controlled in rate mode; these are presented in a table

  19. Prognostic impact of pre-transplantation computed tomography and 67gallium scanning in chemosensitive diffuse large B cell lymphoma patients undergoing hematopoietic stem-cell transplantation

    International Nuclear Information System (INIS)

    Escobar, Ignacio G.; Alonso, Pilar T.; Barrigon, Dolores C.; Perez-Simon, Jose A.; Mateos Manteca, Maria V.; San Miguel Izquierdo, Jesus F.

    2008-01-01

    In the present study, we evaluated computed tomography (CT) and 67 gallium scanning ( 67 Ga scan) pre-transplant as prognostic factors for overall survival (OS) and event-free survival (EFS) in patients with diffuse large B cell lymphoma, undergoing high-dose chemotherapy and stem-cell transplantation. Forty-two patients were included. Of these, 9 (21%) had both positive CT and 67 Ga scans, 17 (41%) negative results with both techniques, and 16 (38%) positive CT/negative 67 Ga scan. Whole-body planar imaging and single-photon emission computed tomography (SPECT) were performed 72 h after an intravenous administration of 67 Ga citrate measuring between 7 mCi and 10 mCi (259-370 MBq). Patients with positive CT/positive 67 Ga scan had a significantly worse EFS and OS at 5 years than those with negative 67 Ga scan regardless of whether it was associated with a positive or a negative CT scan (29% and 16% vs. 81% and 93% vs. 88% and 100%, respectively, P 67 Ga scan and those with positive CT/negative 67 Ga scan, with an EFS and OS at 5 years of 88% versus 81% and 100% versus 93%, respectively. In multivariate analysis, the presence of a pre-transplant positive CT/ 67 Ga scans adversely influenced both EFS and OS [HR 8, 95% confidence interval (CI) (1.4-38), P=0.03 and HR 2; 95% CI (1.3-8), P=0.02, respectively]. 67 Ga scan helps to identify, in the pre-transplant evaluation, two groups with a different outcome: one group of patients with positive CT and negative 67 Ga scans pre-transplant, who showed a favorable outcome with a low rate of relapse, and the other group of patients with both positive CT and 67 Ga scans pre-transplant, who showed a poor prognosis and did not benefit from autologous stem-cell transplantation. They should have been offered other therapeutic strategies. (author)

  20. Computer controlled drifting of Si(Li) detectors

    International Nuclear Information System (INIS)

    Landis, D.A.; Wong, Y.K.; Walton, J.T.; Goulding, F.S.

    1989-01-01

    A relatively inexpensive computer-controlled system for performing the drift process used in fabricating Si(Li) detectors is described. The system employs a small computer to monitor the leakage current, applied voltage and temperature on eight individual drift stations. The associated computer program initializes the drift process, monitors the drift progress and then terminates the drift when an operator set drift time has elapsed. The improved control of the drift with this system has been well demonstrated over the past three years in the fabrication of a variety of Si(Li) detectors. A few representative system responses to detector behavior during the drift process are described

  1. Safety Metrics for Human-Computer Controlled Systems

    Science.gov (United States)

    Leveson, Nancy G; Hatanaka, Iwao

    2000-01-01

    The rapid growth of computer technology and innovation has played a significant role in the rise of computer automation of human tasks in modem production systems across all industries. Although the rationale for automation has been to eliminate "human error" or to relieve humans from manual repetitive tasks, various computer-related hazards and accidents have emerged as a direct result of increased system complexity attributed to computer automation. The risk assessment techniques utilized for electromechanical systems are not suitable for today's software-intensive systems or complex human-computer controlled systems.This thesis will propose a new systemic model-based framework for analyzing risk in safety-critical systems where both computers and humans are controlling safety-critical functions. A new systems accident model will be developed based upon modem systems theory and human cognitive processes to better characterize system accidents, the role of human operators, and the influence of software in its direct control of significant system functions Better risk assessments will then be achievable through the application of this new framework to complex human-computer controlled systems.

  2. Predictive Control of Networked Multiagent Systems via Cloud Computing.

    Science.gov (United States)

    Liu, Guo-Ping

    2017-01-18

    This paper studies the design and analysis of networked multiagent predictive control systems via cloud computing. A cloud predictive control scheme for networked multiagent systems (NMASs) is proposed to achieve consensus and stability simultaneously and to compensate for network delays actively. The design of the cloud predictive controller for NMASs is detailed. The analysis of the cloud predictive control scheme gives the necessary and sufficient conditions of stability and consensus of closed-loop networked multiagent control systems. The proposed scheme is verified to characterize the dynamical behavior and control performance of NMASs through simulations. The outcome provides a foundation for the development of cooperative and coordinative control of NMASs and its applications.

  3. Computer Security: your car, my control

    CERN Multimedia

    Stefan Lueders, Computer Security Team

    2015-01-01

    We have discussed the Internet of Things (IoT) and its security implications already in past issues of the CERN Bulletin, for example in “Today’s paranoia, tomorrow’s reality” (see here). Unfortunately, tomorrow has come. At this years's Black Hat conference researchers presented their findings on how easily your car can be hacked and controlled remotely. Sigh.   While these researchers have just shown that they can wirelessly hijack a Jeep Cherokee, others have performed similar studies with SmartCars, Fords, a Tesla, a Corvette, BMWs, Chryslers and Mercedes! With the increasing computerisation of cars, the engine management system, air conditioning, anti-lock braking system, electronic stability programme, etc. are linked to the infotainment, navigation and communication systems, opening the door for these vehicles to be hacked remotely. The now prevalent Bluetooth connection with smartphones is one entry vector to attack your car remotely...

  4. Computer security of NPP instrumentation and control systems: categorization

    International Nuclear Information System (INIS)

    Klevtsov, A.L.; Simonov, A.A.; Trubchaninov, S.A.

    2016-01-01

    The paper is devoted to studying categorization of NPP instrumentation and control (I&C) systems from the point of view of computer security and to consideration of the computer security levels and zones used by the International Atomic Energy Agency (IAEA). The paper also describes the computer security degrees and zones regulated by the International Electrotechnical Commission (IEC) standard. The computer security categorization of the systems used by the U.S. Nuclear Regulatory Commission (NRC) is presented. The experts analyzed the main differences in I&C systems computer security categorization accepted by the IAEA, IEC and U.S. NRC. The approaches to categorization that should be advisably used in Ukraine during the development of regulation on NPP I&C systems computer security are proposed in the paper

  5. Computer Controlled Chemical Micro-Reactor

    International Nuclear Information System (INIS)

    Mechtilde, Schaefer; Eduard, Stach; Adreas, Foitzik

    2006-01-01

    Chemical reactions or chemical equilibria can be influenced and controlled by several parameters. The ratio of two liquid ingredients, the so called reactants or educts, plays an important role in determining the end product and its yield. The reactants must be weighed and accordingly mixed with the conventional batch mode. If the reaction is done in a microreactor or in several parallel working micro-reactors, units for allotting the educts in appropriate quantities are required. In this report we present a novel micro-reactor that allows the constant monitoring of the chemical reaction via Raman spectroscopy. Such monitoring enables an appropriate feedback on the steering parameters for the PC controlled micro-pumps for the appropriate educt flow rate of both liquids to get optimised ratios of ingredients at an optimised total flow rate. The micro-reactors are the core pieces of the design and are easily removable and can therefore be changed at any time to adapt the requirements of the chemical reaction. One type of reactor consists of a stainless steel base containing small scale milled channels covered with anodically bonded Pyrex glass. Another type of reactor has a base of anisotropically etched silicon, and is also covered with anodically bonded Pyrex glass. The glass window allows visual observation of the initial phase interface of the two educts in the reaction channels by optical microscopy and does not affect, in contrast to infrared spectroscopy, the Raman spectroscopic signal for detection of the reaction kinetics. On the basis of a test reaction, we present non-invasive and spatially highly resolved in-situ reaction analysis using Raman spectroscopy measured along the reaction channel at different locations

  6. Effect of length and location of edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography scans.

    Science.gov (United States)

    Jamjoom, Faris Z; Kim, Do-Gyoon; Lee, Damian J; McGlumphy, Edwin A; Yilmaz, Burak

    2018-02-05

    Effects of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography (CBCT) scans has not been investigated. To evaluate the effect of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into CBCT scans using different methods. Direct digital scans of a completely dentate master model with removable radiopaque teeth were made using an intraoral scanner, and digital scans of stone duplicates of the master model were made using a laboratory scanner. Specific teeth were removed to simulate different clinical situations and their CBCT scans were made. Surface scans were registered onto the CBCT scans. Radiographic templates for each clinical situation were also fabricated and used during CBCT scans of the master models. Using metrology software, three-dimensional (3D) deviation was measured on standard tesselation language (STL) files created from the CBCT scans against an STL file of the master model created from a CBCT scan. Statistical analysis was done using the MIXED procedure in a statistical software and Tukey HSD test (α =.05). The interaction between location and method was significant (P = .009). Location had no significant effect on registration methods (P > .05), but on the radiographic templates (P = .011). Length of the edentulous area did not have any significant effect (P > .05). Accuracy of digital image registration methods was similar and higher than that of radiographic templates in all clinical situations. Tooth-bound radiographic templates were significantly more accurate than the free-end templates. The results of this study suggest using image registration instead of radiographic templates when planning dental implants, particularly in free-end situations. © 2018 Wiley Periodicals, Inc.

  7. Personal computer control system for small size tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, Hiroshi; Kawano, Kazuhiro; Shinozaki, Masataka [Nissin - High Voltage Co. Ltd., Kyoto (Japan)

    1996-12-01

    As the analysis apparatus using tandem accelerator has a lot of control parameter, numbers of control parts set on control panel are so many to make the panel more complex and its operativity worse. In order to improve these faults, development and design of a control system using personal computer for the control panel mainly constituted by conventional hardware parts were tried. Their predominant characteristics are shown as follows: (1) To make the control panel construction simpler and more compact, because the hardware device on the panel surface becomes the smallest limit as required by using a personal computer for man-machine interface. (2) To make control speed more rapid, because sequence control is closed within each block by driving accelerator system to each block and installing local station of the sequencer network at each block. (3) To make expandability larger, because of few improvement of the present hardware by interrupting the sequencer local station into the net and correcting image of the computer when increasing a new beamline. And, (4) to make control system cheaper, because of cheaper investment and easier programming by using the personal computer. (G.K.)

  8. SCAN- a maintenance-free flowrate meter with direct digital read-out for computerised control applications in radiochemical plants

    Energy Technology Data Exchange (ETDEWEB)

    Shah, B V; Siddiqui, I A; Theyyunni, T K [Process Engineering and Systems Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    In radiochemical plants, the choice of flowrate sensor is subject to stringent requirements of fail-safe design and freedom from maintenance. The SCAN remote digital direct indicating flowrate meter described in this paper was developed to meet the requirements of flowrate and transmitting it to the control room, and to a computerised control system. SCAN is designed on the principle that flowrate through an orifice is a function of the head of liquid acting upon it. SCAN consists of a small chamber which receives the flow, and discharges it through an orifice located in bottom. The level of liquid in the pot represents the flowrate of the input stream. SCAN has been developed into an accurate, rugged and practical device by refinements in the design of internals, and by introducing a special end-section which makes the calibration insensitive to location. An important feature of SCAN is that it is passive, maintenance free, fail-safe device and contains no moving parts. There is no liquid hold up in the SCAN when idle, which is a desirable feature for the radiochemical plant environment. (author). 3 figs., 2 tabs.

  9. The iconic memory skills of brain injury survivors and non-brain injured controls after visual scanning training.

    Science.gov (United States)

    McClure, J T; Browning, R T; Vantrease, C M; Bittle, S T

    1994-01-01

    Previous research suggests that traumatic brain injury (TBI) results in impairment of iconic memory abilities.We would like to acknowledge the contribution of Jeffrey D. Vantrease, who wrote the software program for the Iconic Memory procedure and measurement. This raises serious implications for brain injury rehabilitation. Most cognitive rehabilitation programs do not include iconic memory training. Instead it is common for cognitive rehabilitation programs to focus on attention and concentration skills, memory skills, and visual scanning skills.This study compared the iconic memory skills of brain-injury survivors and control subjects who all reached criterion levels of visual scanning skills. This involved previous training for the brain-injury survivors using popular visual scanning programs that allowed them to visually scan with response time and accuracy within normal limits. Control subjects required only minimal training to reach normal limits criteria. This comparison allows for the dissociation of visual scanning skills and iconic memory skills.The results are discussed in terms of their implications for cognitive rehabilitation and the relationship between visual scanning training and iconic memory skills.

  10. Transient ischemic attacks with and without a relevant infarct on computed tomographic scans cannot be distinguished clinically. Dutch Transient Ischemic Attack Study Group

    NARCIS (Netherlands)

    Koudstaal, P. J.; van Gijn, J.; Lodder, J.; Frenken, W. G.; Vermeulen, M.; Franke, C. L.; Hijdra, A.; Bulens, C.

    1991-01-01

    We prospectively studied clinical and computed tomographic (CT) scan findings in 79 patients with a transient ischemic attack (TIA) and a relevant cerebral infarction on CT, also known as cerebral infarction with transient signs (CITS). We compared the results with those of 527 concurrent patients

  11. A cone-beam computed tomography triple scan procedure to obtain a three-dimensional augmented virtual skull model appropriate for orthognathic surgery planning.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Clercq, C. De; Abeloos, J.V.S.; Lamoral, P.; Lippens, F.R.C.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan

  12. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions

    NARCIS (Netherlands)

    Wiranto, Matthew G.; Engelbrecht, W. Petrie; Nolthenius, Heleen E. Tutein; van der Meer, W. Joerd; Ren, Yijin

    INTRODUCTION: Digital 3-dimensional models are widely used for orthodontic diagnosis. The aim of this study was to assess the validity, reliability, and reproducibility of digital models obtained from the Lava Chairside Oral scanner (3M ESPE, Seefeld, Germany) and cone-beam computed tomography scans

  13. The value of indicated computed tomography scan of the chest and abdomen in addition to the conventional radiologic work-up for blunt trauma patients.

    NARCIS (Netherlands)

    Deunk, J.; Dekker, H.M.; Brink, M.; Vugt, R. van; Edwards, M.J.R.; Vugt, A.B. van

    2007-01-01

    BACKGROUND: Multidetector computed tomography (CT) is more sensitive and specific in detecting traumatic injuries than conventional radiology is. However, still little is known about the diagnostic value and the therapeutic impact of indicated thoraco-abdominal CT scan when it is performed in

  14. Control in the cockpit: crews vs. computers.

    Science.gov (United States)

    Ropelewski, R

    1996-08-01

    In the no-holds-barred competition between Boeing and Europe's Airbus Industrie for dominance in the world's commercial jet airliner markets, the question of who--or what--is in charge in the cockpit has been a significant selling point. Airbus, which pioneered highly automated flight controls with its A320 narrow-body transport in the late 1980s, likes to emphasize the "protection" features built into the aircraft through those automated systems. Boeing, which employs many of the same concepts in its new 777 twin-engine widebody transport, tends to put more emphasis on crew involvement in the operation of that aircraft. Is there a difference? In fact, the question has broader implications than those involving the marketing battle between Boeing and Airbus. Airlines, aircraft manufacturers, flight training specialists, human factors gurus, and aviation authorities in various countries are struggling with the isse as automation becomes more and more prevalent on passenger and cargo-carrying aircraft around the world.

  15. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  16. Reconstruction of a whole-body counter into a process computer-controlled low-level whole-body scanner

    International Nuclear Information System (INIS)

    Hamann, C.

    1975-01-01

    A report is given on the state of the research project to reconstruct our whole-body counter with solid geometries into a scanning type one. The object is to develop a process computer controlled 'adaptive system'. The self-built scan mechanics are explained and the advantages and problems of applying stepping motors are gone into. A stepping motor coordinates control is presented. As the planned scanner and the process computer form a digital controlled system, all theoretical and actual values as well as the control orders from the process computer must be directly controllable. A CAMAC system was not used for economical reasons, the process periphery was made controllable by self building of interfaces to and from the computer. As example, the available multi-channel analyzers were converted to external controlling. The price-moderate and relatively simple self-built set-up are outlined and an example is given of how a TELETYPE version is reconstructed into a fast electronic interface. A BUS-MULTIPLEX system was developed which generates all necessary DI/DO interfaces out of one DI and DO address of the process computer only. The essential part of this system is given. (orig./LH) [de

  17. Patterning a hydrogen-bonded molecular monolayer with a hand-controlled scanning probe microscope

    Directory of Open Access Journals (Sweden)

    Matthew F. B. Green

    2014-10-01

    Full Text Available One of the paramount goals in nanotechnology is molecular-scale functional design, which includes arranging molecules into complex structures at will. The first steps towards this goal were made through the invention of the scanning probe microscope (SPM, which put single-atom and single-molecule manipulation into practice for the first time. Extending the controlled manipulation to larger molecules is expected to multiply the potential of engineered nanostructures. Here we report an enhancement of the SPM technique that makes the manipulation of large molecular adsorbates much more effective. By using a commercial motion tracking system, we couple the movements of an operator's hand to the sub-angstrom precise positioning of an SPM tip. Literally moving the tip by hand we write a nanoscale structure in a monolayer of large molecules, thereby showing that our method allows for the successful execution of complex manipulation protocols even when the potential energy surface that governs the interaction behaviour of the manipulated nanoscale object(s is largely unknown.

  18. A computer-controlled conformal radiotherapy system I: overview

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; McShan, Daniel L.; Kessler, Marc L.; Matrone, Gwynne M.; Lewis, James D.; Weaver, Tamar A.

    1995-01-01

    Purpose: Equipment developed for use with computer-controlled conformal radiotherapy (CCRT) treatment techniques, including multileaf collimators and/or computer-control systems for treatment machines, are now available. The purpose of this work is to develop a system that will allow the safe, efficient, and accurate delivery of CCRT treatments as routine clinical treatments, and permit modifications of the system so that the delivery process can be optimized. Methods and Materials: The needs and requirements for a system that can fully support modern computer-controlled treatment machines equipped with multileaf collimators and segmental or dynamic conformal therapy capabilities have been analyzed and evaluated. This analysis has been used to design and then implement a complete approach to the delivery of CCRT treatments. Results: The computer-controlled conformal radiotherapy system (CCRS) described here consists of a process for the delivery of CCRT treatments, and a complex software system that implements the treatment process. The CCRS system described here includes systems for plan transfer, treatment delivery planning, sequencing of the actual treatment delivery process, graphical simulation and verification tools, as well as an electronic chart that is an integral part of the system. The CCRS system has been implemented for use with a number of different treatment machines. The system has been used clinically for more than 2 years to perform CCRT treatments for more than 200 patients. Conclusions: A comprehensive system for the implementation and delivery of computer-controlled conformal radiation therapy (CCRT) plans has been designed and implemented for routine clinical use with multisegment, computer-controlled, multileaf-collimated conformal therapy. The CCRS system has been successfully implemented to perform these complex treatments, and is considered quite important to the clinical use of modern computer-controlled treatment techniques

  19. A computer control system for a research reactor

    International Nuclear Information System (INIS)

    Crawford, K.C.; Sandquist, G.M.

    1987-01-01

    Most reactor applications until now, have not required computer control of core output. Commercial reactors are generally operated at a constant power output to provide baseline power. However, if commercial reactor cores are to become load following over a wide range, then centralized digital computer control is required to make the entire facility respond as a single unit to continual changes in power demand. Navy and research reactors are much smaller and simpler and are operated at constant power levels as required, without concern for the number of operators required to operate the facility. For navy reactors, centralized digital computer control may provide space savings and reduced personnel requirements. Computer control offers research reactors versatility to efficiently change a system to develop new ideas. The operation of any reactor facility would be enhanced by a controller that does not panic and is continually monitoring all facility parameters. Eventually very sophisticated computer control systems may be developed which will sense operational problems, diagnose the problem, and depending on the severity of the problem, immediately activate safety systems or consult with operators before taking action

  20. CAMAC system for computer control of microwave spectrometers

    International Nuclear Information System (INIS)

    Zizka, G.; Turko, B.; Kolbe, B.

    1979-01-01

    An interface between a microwave spectrometer and a computer is described. It consists of three CAMAC modules and uses a standard CAMAC crate and controller. The hardware, in conjunction with appropriate software routines was designed to synchronize measurements, to collect data, and to control the microwave frequency and other experimental parameters

  1. An improved computer controlled triple-axis neutron spectrometer

    International Nuclear Information System (INIS)

    Cooper, M.J.; Hall, J.W.; Hutchings, M.T.

    1975-07-01

    A description is given of the computer-controlled triple-axis neutron spectrometer installed at the PLUTO reactor at Harwell. The reasons for an nature of recent major improvements are discussed. Following a general description of the spectrometer, details are then given of the new computerised control system, including the functions of the various programs which are now available to the user. (author)

  2. Decoherence control in quantum computing with simple chirped ...

    Indian Academy of Sciences (India)

    We show how the use of optimally shaped pulses to guide the time evolution of a system ('coherent control') can be an effective approach towards quantum computation logic. We demonstrate this with selective control of decoherence for a multilevel system with a simple linearly chirped pulse. We use a multiphoton ...

  3. Computer-supported quality control in X-ray diagnosis

    International Nuclear Information System (INIS)

    Maier, W.; Klotz, E.

    1989-01-01

    Quality control of X-ray facilities in radiological departments of large hospitals is possible only if the instrumentation used for measurements is interfaced to a computer. The central computer helps to organize the measurements as well as analyse and record the results. It can also be connected to a densitometer and camera for evaluating radiographs of test devices. Other quality control tests are supported by a mobile station with equipment for non-invasive dosimetry measurements. Experience with a computer-supported system in quality control of film and film processing is described and the evaluation methods of ANSI and the German industrial standard DIN are compared. The disadvantage of these methods is the exclusion of film quality parameters, which can make processing control almost worthless. (author)

  4. Quantification of Mediastinal and Hilar Lymph Node Movement Using Four-Dimensional Computed Tomography Scan: Implications for Radiation Treatment Planning

    International Nuclear Information System (INIS)

    Sher, David J.; Wolfgang, John A.; Niemierko, Andrzej; Choi, Noah C.

    2007-01-01

    Purpose: To quantitatively describe mediastinal and hilar lymph node movement in patients with lymph node-positive lung cancer. Methods and Materials: Twenty-four patients with lung cancer who underwent four-dimensional computed tomography scanning at Massachusetts General Hospital were included in the study. The maximum extent of superior motion of the superior border was measured, as well as the maximum inferior movement of the inferior border. The average of these two values is defined as the peak-to-peak movement. This process was repeated for mediolateral (ML) and anterior-posterior (AP) movement. Linear regression was used to determine lymph node characteristics associated with peak-to-peak movement. Various uniform expansions were investigated to determine the expansion margins necessary to ensure complete internal target volume (ITV) coverage. Results: The mean peak-to-peak displacements of paratracheal lymph nodes were 4 mm (craniocaudal [CC]), 2 mm (ML), and 2 mm (AP). For subcarinal lymph nodes, the mean peak-to-peak movements were 6 mm (CC), 4 mm (ML), and 2 mm (AP). The mean peak-to-peak displacements of hilar lymph nodes were 7 mm (CC), 1 mm (ML), and 4 mm (AP). On multivariate analysis, lymph node station and lymph node size were significantly related to peak-to-peak movement. Expansions of 8 mm for paratracheal nodes and 13 mm for subcarinal and hilar nodes would have been necessary to cover the ITV of 95% of these nodal masses. Conclusions: Subcarinal and hilar lymph nodes may move substantially throughout the respiratory cycle. In the absence of patient-specific information on nodal motion, expansions of at least 8 mm, 13 mm, and 13 mm should be considered to cover the ITV of paratracheal, subcarinal, and hilar lymph nodes, respectively

  5. Fluid mechanics of human fetal right ventricles from image-based computational fluid dynamics using 4D clinical ultrasound scans.

    Science.gov (United States)

    Wiputra, Hadi; Lai, Chang Quan; Lim, Guat Ling; Heng, Joel Jia Wei; Guo, Lan; Soomar, Sanah Merchant; Leo, Hwa Liang; Biwas, Arijit; Mattar, Citra Nurfarah Zaini; Yap, Choon Hwai

    2016-12-01

    There are 0.6-1.9% of US children who were born with congenital heart malformations. Clinical and animal studies suggest that abnormal blood flow forces might play a role in causing these malformation, highlighting the importance of understanding the fetal cardiovascular fluid mechanics. We performed computational fluid dynamics simulations of the right ventricles, based on four-dimensional ultrasound scans of three 20-wk-old normal human fetuses, to characterize their flow and energy dynamics. Peak intraventricular pressure gradients were found to be 0.2-0.9 mmHg during systole, and 0.1-0.2 mmHg during diastole. Diastolic wall shear stresses were found to be around 1 Pa, which could elevate to 2-4 Pa during systole in the outflow tract. Fetal right ventricles have complex flow patterns featuring two interacting diastolic vortex rings, formed during diastolic E wave and A wave. These rings persisted through the end of systole and elevated wall shear stresses in their proximity. They were observed to conserve ∼25.0% of peak diastolic kinetic energy to be carried over into the subsequent systole. However, this carried-over kinetic energy did not significantly alter the work done by the heart for ejection. Thus, while diastolic vortexes played a significant role in determining spatial patterns and magnitudes of diastolic wall shear stresses, they did not have significant influence on systolic ejection. Our results can serve as a baseline for future comparison with diseased hearts. Copyright © 2016 the American Physiological Society.

  6. Incidence of lumbar spondylolysis in the general population in Japan based on multidetector computed tomography scans from two thousand subjects.

    Science.gov (United States)

    Sakai, Toshinori; Sairyo, Koichi; Takao, Shoichiro; Nishitani, Hiromu; Yasui, Natsuo

    2009-10-01

    Epidemiological analysis using CTs. To investigate the true incidence of lumbar spondylolysis in the general population in Japan. Although there have been several reports on the incidence of lumbar spondylolysis, they had some weakness. One of them concerns the subjects investigated, because the incidence of lumbar spondylolysis varies considerably, and some patients are asymptomatic. In addition, most of the past studies used plain radiograph films or skeletal investigation. Therefore, the past reported incidence may not correspond to that of the general population. We reviewed the computed tomography (CT) scans of 2000 subjects (age: 20-92 years) who had undergone abdominal and pelvic CT on a single multidetector CT scanner for reasons unrelated to low back pain. We reviewed them for spondylolysis, spondylolytic spondylolisthesis, and spina bifida occulta (SBO) in the lumbosacral region. The grade (I-IV) of spondylolisthesis was measured using midsagittal reconstructions. Lumbar spondylolysis was found in 117 subjects (5.9%). Their male-female ratio was 2:1. Multiple-level spondylolysis was found in 5 subjects (0.3%). Among these 117 subjects, there were 124 vertebrae with spondylolysis. Of them, 112 (90.3%) corresponded to L5, and 26 (21.0%) had unilateral spondylolysis.SBO was found in 154 subjects. Of them, 25 had spondylolysis (16.2%), whereas, in 1846 subjects without SBO, 92 had spondylolysis (5.0%). The incidence of spondylolysis among the patients with SBO was significantly higher than that in subjects without SBO (Odd ratio was 3.7-fold).Of 124 vertebrae with spondylolysis, 75 (60.5%) showed low-grade (Meyerding grade I or II) spondylolisthesis, and no subject presented high-grade spondylolisthesis. Spondylolisthesis was found in 74.5% of the subjects with bilateral spondylolysis, and in 7.7% of those with unilateral spondylolysis. The incidence of lumbar spondylolysis in the Japanese general population was 5.9% (males: 7.9%, females: 3.9%).

  7. Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance

    International Nuclear Information System (INIS)

    Roos, Justus E.; Paik, David; Olsen, David; Liu, Emily G.; Leung, Ann N.; Mindelzun, Robert; Choudhury, Kingshuk R.; Napel, Sandy; Rubin, Geoffrey D.; Chow, Lawrence C.; Naidich, David P.

    2010-01-01

    The diagnostic performance of radiologists using incremental CAD assistance for lung nodule detection on CT and their temporal variation in performance during CAD evaluation was assessed. CAD was applied to 20 chest multidetector-row computed tomography (MDCT) scans containing 190 non-calcified ≥3-mm nodules. After free search, three radiologists independently evaluated a maximum of up to 50 CAD detections/patient. Multiple free-response ROC curves were generated for free search and successive CAD evaluation, by incrementally adding CAD detections one at a time to the radiologists' performance. The sensitivity for free search was 53% (range, 44%-59%) at 1.15 false positives (FP)/patient and increased with CAD to 69% (range, 59-82%) at 1.45 FP/patient. CAD evaluation initially resulted in a sharp rise in sensitivity of 14% with a minimal increase in FP over a time period of 100 s, followed by flattening of the sensitivity increase to only 2%. This transition resulted from a greater prevalence of true positive (TP) versus FP detections at early CAD evaluation and not by a temporal change in readers' performance. The time spent for TP (9.5 s ± 4.5 s) and false negative (FN) (8.4 s ± 6.7 s) detections was similar; FP decisions took two- to three-times longer (14.4 s ± 8.7 s) than true negative (TN) decisions (4.7 s ± 1.3 s). When CAD output is ordered by CAD score, an initial period of rapid performance improvement slows significantly over time because of non-uniformity in the distribution of TP CAD output and not to a changing reader performance over time. (orig.)

  8. Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Sennst, Dirk-Alexander; Maxlmoser, Wolfgang; Kalender, Willi A.

    2002-01-01

    Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 deg. MCD and 180 deg. MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorithms provided by the CT manufacturers, high image quality can be achieved. These algorithms require information about the cardiac motion, i.e., typically the simultaneously recorded electrocardiogram (ECG), to synchronize the reconstruction with the cardiac motion. Neither data acquired without ECG information (standard patients) nor acquisitions with corrupted ECG information can be handled adequately. We developed a method to extract the appropriate information about cardiac motion directly from the measured raw data (projection data). The so-called kymogram function is a measure of the cardiac motion as a function of time t or as a function of the projection angle α. In contrast to the ECG which is a global measure of the heart's electric excitation, the kymogram is a local measure of the heart motion at the z-position z(α) at projection angle α. The patient's local heart rate as well as the necessary synchronization information to be used with phase-correlated algorithms can be extracted from the kymogram by using a series of signal processing steps. The kymogram information is shown to be adequate to substitute the ECG information. Computer simulations with simulated ECG and patient measurements with simultaneously acquired ECG were carried out for a multislice scanner providing M=4 slices to evaluate these new approaches. Both the ECG function and the kymogram function were used for reconstruction. Both were highly correlated regarding the periodicity information used for reconstruction. In 21 out of 25 consecutive cases the kymogram approach was equivalent to the ECG-correlated reconstruction; only minor differences in image quality between both

  9. Centralized digital computer control of a research nuclear reactor

    International Nuclear Information System (INIS)

    Crawford, K.C.

    1987-01-01

    A hardware and software design for the centralized control of a research nuclear reactor by a digital computer are presented, as well as an investigation of automatic-feedback control. Current reactor-control philosophies including redundancy, inherent safety in failure, and conservative-yet-operational scram initiation were used as the bases of the design. The control philosophies were applied to the power-monitoring system, the fuel-temperature monitoring system, the area-radiation monitoring system, and the overall system interaction. Unlike the single-function analog computers currently used to control research and commercial reactors, this system will be driven by a multifunction digital computer. Specifically, the system will perform control-rod movements to conform with operator requests, automatically log the required physical parameters during reactor operation, perform the required system tests, and monitor facility safety and security. Reactor power control is based on signals received from ion chambers located near the reactor core. Absorber-rod movements are made to control the rate of power increase or decrease during power changes and to control the power level during steady-state operation. Additionally, the system incorporates a rudimentary level of artificial intelligence

  10. Emotor control: computations underlying bodily resource allocation, emotions, and confidence.

    Science.gov (United States)

    Kepecs, Adam; Mensh, Brett D

    2015-12-01

    Emotional processes are central to behavior, yet their deeply subjective nature has been a challenge for neuroscientific study as well as for psychiatric diagnosis. Here we explore the relationships between subjective feelings and their underlying brain circuits from a computational perspective. We apply recent insights from systems neuroscience-approaching subjective behavior as the result of mental computations instantiated in the brain-to the study of emotions. We develop the hypothesis that emotions are the product of neural computations whose motor role is to reallocate bodily resources mostly gated by smooth muscles. This "emotor" control system is analagous to the more familiar motor control computations that coordinate skeletal muscle movements. To illustrate this framework, we review recent research on "confidence." Although familiar as a feeling, confidence is also an objective statistical quantity: an estimate of the probability that a hypothesis is correct. This model-based approach helped reveal the neural basis of decision confidence in mammals and provides a bridge to the subjective feeling of confidence in humans. These results have important implications for psychiatry, since disorders of confidence computations appear to contribute to a number of psychopathologies. More broadly, this computational approach to emotions resonates with the emerging view that psychiatric nosology may be best parameterized in terms of disorders of the cognitive computations underlying complex behavior.

  11. Computer control of the TFTR tritium storage and delivery system

    International Nuclear Information System (INIS)

    Youssef, N.; Phillips, H.; Yemin, L.; Dong, J.; Pierce, C.

    1980-01-01

    The Tritium Storage and Delivery System (TSDS) will deliver to the torus the required tritium gas in precisely controlled injection profiles. This system will utilize advanced Central Instrumentation, Control and Data Acquisition (CICADA) computer-control techniques, in normal and malfunction-recovery modes of operation. The control scheme of the TSDS is built of three main control scenarios. An operating mode defines the permissives, sequence and path of a process during each scenario. The computerized control of the TSDS has four distinct advantages: (1) versatile control with fast response times both for tritium gas generation and for gas injection into the torus; (2) ease of selecting the proper operating modes of a control scenario, (3) ease of operation without disturbing the multiple levels of containment, and (4) simple fast trouble shooting of system malfunction utilizing programmed procedures and on-line diagnosis. The TSDS has both remote nd local control capability

  12. Automated quantification of pulmonary emphysema from computed tomography scans: comparison of variation and correlation of common measures in a large cohort

    Science.gov (United States)

    Keller, Brad M.; Reeves, Anthony P.; Yankelevitz, David F.; Henschke, Claudia I.

    2010-03-01

    The purpose of this work was to retrospectively investigate the variation of standard indices of pulmonary emphysema from helical computed tomographic (CT) scans as related to inspiration differences over a 1 year interval and determine the strength of the relationship between these measures in a large cohort. 626 patients that had 2 scans taken at an interval of 9 months to 15 months (μ: 381 days, σ: 31 days) were selected for this work. All scans were acquired at a 1.25mm slice thickness using a low dose protocol. For each scan, the emphysema index (EI), fractal dimension (FD), mean lung density (MLD), and 15th percentile of the histogram (HIST) were computed. The absolute and relative changes for each measure were computed and the empirical 95% confidence interval was reported both in non-normalized and normalized scales. Spearman correlation coefficients are computed between the relative change in each measure and relative change in inspiration between each scan-pair, as well as between each pair-wise combination of the four measures. EI varied on a range of -10.5 to 10.5 on a non-normalized scale and -15 to 15 on a normalized scale, with FD and MLD showing slightly larger but comparable spreads, and HIST having a much larger variation. MLD was found to show the strongest correlation to inspiration change (r=0.85, pemphysema index and fractal dimension have the least variability overall of the commonly used measures of emphysema and that they offer the most unique quantification of emphysema relative to each other.

  13. A computer-controlled conformal radiotherapy system. IV: Electronic chart

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; McShan, Daniel L.; Matrone, Gwynne M.; Weaver, Tamar A.; Lewis, James D.; Kessler, Marc L.

    1995-01-01

    Purpose: The design and implementation of a system for electronically tracking relevant plan, prescription, and treatment data for computer-controlled conformal radiation therapy is described. Methods and Materials: The electronic charting system is implemented on a computer cluster coupled by high-speed networks to computer-controlled therapy machines. A methodical approach to the specification and design of an integrated solution has been used in developing the system. The electronic chart system is designed to allow identification and access of patient-specific data including treatment-planning data, treatment prescription information, and charting of doses. An in-house developed database system is used to provide an integrated approach to the database requirements of the design. A hierarchy of databases is used for both centralization and distribution of the treatment data for specific treatment machines. Results: The basic electronic database system has been implemented and has been in use since July 1993. The system has been used to download and manage treatment data on all patients treated on our first fully computer-controlled treatment machine. To date, electronic dose charting functions have not been fully implemented clinically, requiring the continued use of paper charting for dose tracking. Conclusions: The routine clinical application of complex computer-controlled conformal treatment procedures requires the management of large quantities of information for describing and tracking treatments. An integrated and comprehensive approach to this problem has led to a full electronic chart for conformal radiation therapy treatments

  14. Evaluation of an exposed-radiation dose on a dual-source cardiac computed tomography examination with a prospective electrocardiogram-gated fast dual spiral scan

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Koshida, Kichiro; Koshida, Haruka; Sakuta, Keita; Hayashi, Hiroyuki; Takata, Tadanori; Horii, Junsei; Kawai, Keiichi; Yamamoto, Tomoyuki

    2012-01-01

    We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.03 mGy for the breast, 9.96 mGy for the heart, 6.60 mGy for the lung, 6.48 mGy for the bone marrow, 9.73 mGy for the thymus, and 4.58 mGy for the skin. These values were about 5% of the absorbed doses for the retrospective ECG-gated dual spiral scan. However, the absorbed dose differed greatly at each scan, especially in the external organs such as the breast. For effective and safe use of the prospective ECG-gated fast dual spiral scan, it is necessary to understand these characteristics sufficiently. (author)

  15. 3-D conformal radiation therapy - Part II: Computer-controlled 3-D treatment delivery

    International Nuclear Information System (INIS)

    Benedick, A.

    1997-01-01

    scanned beam treatments will also be discussed. CCRT-related approaches to treatment plan generation and transfer, accelerator control systems, treatment delivery, verification, documentation and charting will also be discussed, including the importance of real-time portal imaging for conformal therapy. The potential benefits of 3-D computer-controlled conformal treatment delivery will be illustrated with results from on-going clinical dose escalation and normal tissue complication studies. Conclusion: A large amount of interest in computer-controlled conformal treatment delivery techniques has developed in recent years. This presentation will attempt to summarize the current status of clinical and research work in 3-D computer-controlled conformal therapy treatment techniques. Particular attention is paid to issues related to implementation and clinical use of this developing treatment modality

  16. Mechatronic Model Based Computed Torque Control of a Parallel Manipulator

    Directory of Open Access Journals (Sweden)

    Zhiyong Yang

    2008-11-01

    Full Text Available With high speed and accuracy the parallel manipulators have wide application in the industry, but there still exist many difficulties in the actual control process because of the time-varying and coupling. Unfortunately, the present-day commercial controlles cannot provide satisfying performance for its single axis linear control only. Therefore, aimed at a novel 2-DOF (Degree of Freedom parallel manipulator called Diamond 600, a motor-mechanism coupling dynamic model based control scheme employing the computed torque control algorithm are presented in this paper. First, the integrated dynamic coupling model is deduced, according to equivalent torques between the mechanical structure and the PM (Permanent Magnetism servomotor. Second, computed torque controller is described in detail for the above proposed model. At last, a series of numerical simulations and experiments are carried out to test the effectiveness of the system, and the results verify the favourable tracking ability and robustness.

  17. Mechatronic Model Based Computed Torque Control of a Parallel Manipulator

    Directory of Open Access Journals (Sweden)

    Zhiyong Yang

    2008-03-01

    Full Text Available With high speed and accuracy the parallel manipulators have wide application in the industry, but there still exist many difficulties in the actual control process because of the time-varying and coupling. Unfortunately, the present-day commercial controlles cannot provide satisfying performance for its single axis linear control only. Therefore, aimed at a novel 2-DOF (Degree of Freedom parallel manipulator called Diamond 600, a motor-mechanism coupling dynamic model based control scheme employing the computed torque control algorithm are presented in this paper. First, the integrated dynamic coupling model is deduced, according to equivalent torques between the mechanical structure and the PM (Permanent Magnetism servomotor. Second, computed torque controller is described in detail for the above proposed model. At last, a series of numerical simulations and experiments are carried out to test the effectiveness of the system, and the results verify the favourable tracking ability and robustness.

  18. The impact of new computer technology on accelerator control

    International Nuclear Information System (INIS)

    Theil, E.; Jacobson, V.; Paxson, V.

    1987-01-01

    This paper describes some recent developments in computing and stresses their application to accelerator control systems. Among the advances that promise to have a significant impact are: i) low cost scientific workstations; ii) the use of ''windows'', pointing devices and menus in a multitasking operating system; iii) high resolution large-screen graphics monitors; iv) new kinds of high bandwidth local area networks. The relevant features are related to a general accelerator control system. For example, the authors examine the implications of a computing environment which permits and encourages graphical manipulation of system components, rather than traditional access through the writing of programs or ''canned'' access via touch panels

  19. The impact of new computer technology on accelerator control

    International Nuclear Information System (INIS)

    Theil, E.; Jacobson, V.; Paxson, V.

    1987-04-01

    This paper describes some recent developments in computing and stresses their application in accelerator control systems. Among the advances that promise to have a significant impact are (1) low cost scientific workstations; (2) the use of ''windows'', pointing devices and menus in a multi-tasking operating system; (3) high resolution large-screen graphics monitors; (4) new kinds of high bandwidth local area networks. The relevant features are related to a general accelerator control system. For example, this paper examines the implications of a computing environment which permits and encourages graphical manipulation of system components, rather than traditional access through the writing of programs or ''canned'' access via touch panels

  20. Computer control of fuel handling activities at FFTF

    International Nuclear Information System (INIS)

    Romrell, D.M.

    1985-03-01

    The Fast Flux Test Facility near Richland, Washington, utilizes computer control for reactor refueling and other related core component handling and processing tasks. The computer controlled tasks described in this paper include core component transfers within the reactor vessel, core component transfers into and out of the reactor vessel, remote duct measurements of irradiated core components, remote duct cutting, and finally, transferring irradiated components out of the reactor containment building for off-site shipments or to long term storage. 3 refs., 16 figs