WorldWideScience

Sample records for computer axial tomography scanning

  1. Tomography system having axial scanning

    International Nuclear Information System (INIS)

    1976-01-01

    An improved method and apparatus has been invented for the transaxial tomographic scanning of a patient to determine mass distribution internal to the patient. A scanning system is provided having a rotatably mounted X-ray radiation source/detector assembly which orbits and scans the patient in plane of orbit. The source provides a plurality of beams of radiation in the orbital plane. Beams pass through the patient to an array of detectors which are spaced in the plane of orbit and respectively aligned with one of the beams. Radiation intensity data is collected at predetermined orientations of each beam-detector pair as the assembly orbits about the patient

  2. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  3. Medullary sponge kidney on axial computed tomography

    International Nuclear Information System (INIS)

    Ginalski, J.-M.; Schnyder, Pierre; Portmann, Luc; Jaeger, Philippe

    1991-01-01

    To evaluate features of medullary sponge kidney (MSK) on computed tomography (CT), 4-mm-thick axial slices without intravenous contrast material were 1st made in 13 patients through 24 kidneys which showed images of MSK on excretory urograms. On CT, papillary calcifications were found in 11 kidneys. In 5 of these, the calcifications were not detectable on plain films. Some hyperdense papillae (attenuation value 55-70 Hounsfield units) without calcification were found in 4 other kidneys. 9 kidneys appeared normal. 10 of the 14 kidneys were reexamined by a 2nd series of 4-mm-thick axial slices, 5 min after intravenous injection of 50 ml of Urografin. Images suggesting possible ectasia of precaliceal tubules were found in only 4 kidneys. These images appear much less obvious and characteristic on CT than on excretory urogram and do nothing more than suggest the possibility of MSK. In conclusion, the sensitivity of CT in the detection of MSK is markedly lower than that of excretory urography. In the most florid cases of the disease, CT can only show images suggesting the possibility of MSK. On the other hand, CT appears much more sensitive than plain films and tomograms of excretory in the detection of papillary calcifications, the most frequent complication of MSK. (author). 13 refs.; 3 figs

  4. A review of X-ray computed axial tomography

    International Nuclear Information System (INIS)

    Schmidt, M.

    1989-01-01

    A review of Computed axial tomography (CAT) scanning literature outlining the theoretical and practical aspects of this technique with application in both medical diagnosis and industrial non-destructive inspection (NDI) is presented. Practical aspects of CAT scanning discussed include : radiation sources, currently available spatial and contrast resolution limits and the evolution of the computerized tomography (CT) system. It was found that monochromatic gamma rays are preferred to X-rays, especially for very high density materials, and that in medical CAT scanning, the special resolution is only, 0.5 mm while spatial resolutions of less than 50μm have been achieved in NDI. An increased number of scientific and industrial applications are anticipated (e.g. for studying sintering reactions), as the capital cost of CAT scanning decreased. 13 refs., 9 figs., 2 tabs

  5. Coronary computed tomography angiography using prospective electrocardiography-gated axial scans with 64-detector computed tomography. Evaluation of stair-step artifacts and padding time

    International Nuclear Information System (INIS)

    Kimura, Fumiko; Umezawa, Tatsuo; Asano, Tomonari; Chihara, Ruri; Nishi, Naoko; Nishimura, Shigeyoshi; Sakai, Fumikazu

    2010-01-01

    We compared stair-step artifacts and radiation dose between prospective electrocardiography (ECG)-gated coronary computed tomography angiography (prospective CCTA) and retrospective CCTA using 64-detector CT and determined the optimal padding time (PT) for prospective CCTA. We retrospectively evaluated 183 patients [mean heart rate (HR) <65 beats/min, maximum HR instability <5 beats/min] who had undergone CCTA. We scored stair-step artifacts from 1 (severe) to 5 (none) and evaluated the effective dose in 53 patients with retrospective CCTA and 130 with prospective CCTA (PT 200 ms, n=32; PT 50 ms, n=98). Mean artifact scores were 4.3 in both retrospective and prospective CCTAs. However, statistically more arteries scored <3 (nonassessable) on prospective CCTA (P<0.001). Mean scores for prospective CCTA with 200- and 50-ms PT were 4.1 and 4.3, respectively (no significant difference). The radiation dose of prospective CCTA was reduced by 59.1% to 80.7%. Prospective CCTA reduces the radiation dose and allows diagnostic imaging in most cases but shows more nonevaluable artifacts than retrospective CCTA. Use of 50-ms instead of 200-ms PT appears to maintain image quality in patients with a mean HR <65 beats/min and HR instability of <5 beats/min. (author)

  6. Minimising medically unwarranted computed tomography scans

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    As computed tomography (CT) is such a superb diagnostic tool and individual CT risks are small, whenever a CT scan is clinically warranted, the CT benefit/risk balance is by far in the patient’s favour. However, if a CT scan is not clinically warranted, this balance shifts dramatically. It is likely that at least 25% of CT scans fall into this latter category, in that they could either be replaced with alternative imaging modalities or could be avoided entirely. Use of clinical decision rules for CT usage represents a powerful approach for slowing down the increase in CT usage, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they may not be clinically helpful.

  7. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  8. Computed tomography scans of metastatic hepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Fukuda, Haruyuki; Nemoto, Yutaka [Osaka City Univ. (Japan). Faculty of Medicine

    1984-01-01

    Computed tomography scans of 114 metastatic hepatic tumors were reviewed. Central low density was found in 82 cases (71.9%) and seems to be characteristic to metastatic hepatic tumors. Dynamic CT was performed on 34 cases, and 21 (61.8%) of these had ring enhancement at the arterial phase. Most of metastatic hepatic tumors could be differentiated from hepatocellular carcinoma. However, metastatic hepatic tumors from renal cell carcinoma, renal rhabdomyosarcoma, malignant melanoma and leiomyosarcoma could not be differentiated from hepatocellular carcinoma, even with use of dynamic study.

  9. Axial tomography

    International Nuclear Information System (INIS)

    Brueckner, K.A.; Lewis, J.H.

    1979-01-01

    The invention relates to axial tomography, sometimes referred to as cross-sectional x-ray. The apparatus described may utilize the conventional x-ray or ultrasonic source and detector and scanning mechanism for producing the plurality of sets of radiation detector output signals. It has the means for storing the detector output signals in analog form with the signals of one set overlying the signals of another set so that signals resulting from radiation through a zone of the object being examined are summed at a corresponding zone in the storage device, typically an electronic storage tube. The summed signals are read from the storage device with a radially inversely proportional reader producing a second signal for storage, again typically in an electronic storage tube. These signals stored in the second storage device are read with Laplacian relation, with the resultant sigal being a video signal that may be connected to a TV monitor for display of the sectional image. In alternative embodiments, optical film systems and electrostatic systems are utilized. (JTA)

  10. Ward nurses' knowledge of computed tomography scanning.

    Science.gov (United States)

    Majeed, M A; Nayeemuddin, M; Christie, M

    Patients benefit from and are reassured by advance information on procedures that they are to undergo. Ward nurses should have adequate knowledge of radiological investigations to ensure proper patient preparation and good interdepartmental communication to avoid delays and cancellations. This study was conducted to assess the ward nurses' knowledge of the process of computed tomography (CT) scanning. One hundred and twenty qualified nurses were asked to complete a questionnaire regarding CT scanning. The findings revealed a suboptimal level of awareness about the process. This is probably due to lack of formal teaching for nurses on the wards in regards the different radiological procedures and patient preparation. There is a strong case for better educational talks on rapidly changing radiological techniques for ward staff to ensure high-quality patient care.

  11. Subclinical coronary atherosclerosis by multi-scan axial tomography and its association with hyperglycemia

    International Nuclear Information System (INIS)

    Buchaca Faxas, Emilio F; Bencomo Rodriguez, Llimia; Bermudez Rojas, Sergio

    2010-01-01

    A study was conducted to assess the usefulness of multi-scan axial tomography techniques to detect, in a subclinical stage, the coronary damage in patients presenting with diabetes mellitus (DM) to describe the frequency of asymptomatic atherosclerotic affection and its potential association with the fasting and postprandial hyperglycemia. In study were included 59 patients with type 2 diabetes to compare the results of coronary calcium determination with the findings of angiography by multi-scan axial computed tomography (CAT-M). There was a concordance of a 44.1% between both studies, as well as a predominance of soft plaques in the 55.9 % of patients. The 42.4 % showed a narrowing of arterial lumen, which was significant in the 16.5 % of total. A high figure of patients with hyperglycemia had coronary damage compared to those ills with a good glycemia control (p = 0.024). This relation was more evident with the postprandial hyperglycemia (= 0.016). Hyperglycemia had a high opportunity (5.99 times) to detect coronary lesions by TAC-C compared to other major atherosclerosis risk factors like the high blood pressure, smoking, dyslipemias expressed in a significant way (p 0.045). We conclude that Angio TAC-C and Calcio Score techniques are useful to detect lesions of coronary arteries in patients with type 2 diabetes mellitus without symptoms of myocardial ischemia, which was associated to presence of a hyperglycemia, fundamentally postprandial

  12. SPECT: Theoretical aspecte and evolution of emission computed axial tomography

    International Nuclear Information System (INIS)

    Brunol, J.; Nuta, V.

    1981-01-01

    We have detailed certain of the elements of 3-D image reconstruction from axial projections. Two of the aspects specific to nuclear medicine have been analysed namely self-absorption and statistics. In our view, the development of ECAT in the months to come must hence proceed in two essential directions: - application to dynamic cardiac imagery (multigated). Results of this type have been obtained over 8 months in the Radioisotope Service of Cochin Hospital in Paris. It must be stressed here that the number of images to be processed then becomes considerable (multiplication by the gate factor yielding more than 100 images), the more the statistics are reduced due to the fact of the temporal separation. The obtaining of good image quality requires sophisticated quadri-dimensional processing. It follows that the computing times, with all the mini-computers available in nuclear medicine, then become much too great to envisage really application in hospital routine (several hours of computing). This is the reason why we connected an array processor with the IMAC system. This very powerful system (several tens of times the power of a mini-computer) will reduce the time of such computing to less than 10 minutes. New elements can be introduced into the reconstruction algorithm (static case opposite the foregoing one). These important elements of improvement are to the detriment of space and hence of computing time. Here again, the use of an array processor appears indispensable. It is to recall that the ECAT is today a currently used method, the theoretical analyses that it has necessitated have opened the way to new effective methods of tomography by 'Slanted Hole'. (orig.) [de

  13. Target localization on standard axial images in computed tomography (CT) stereotaxis for functional neurosurgery - a technical note

    International Nuclear Information System (INIS)

    Patil, A.-A.

    1986-01-01

    A simple technique for marking functional neurosurgery target on computed tomography (CT) axial image is described. This permits the use of standard axial image for computed tomography (CT) stereotaxis in functional neurosurgery. (Author)

  14. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  15. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  16. [Axial computer tomography of the neurocranium (author's transl)].

    Science.gov (United States)

    Stöppler, L

    1977-05-27

    Computer tomography (CT), a new radiographic examination technique, is very highly efficient, for it has high informative content with little stress for the patient. In contrast to the conventional X-ray technology, CT succeeds, by direct presentation of the structure of the soft parts, in obtaining information which comes close to that of macroscopic neuropathology. The capacity and limitations of the method at the present stage of development are reported. Computer tomography cannot displace conventional neuroradiological methods of investigation, although it is rightly presented as a screening method and helps towards selective use. Indications, technical integration and handling of CT are prerequisites for the exhaustive benefit of the excellent new technique.

  17. Transverse axial plane anatomy of the temporal bone employing high spatial resolution computed tomography

    International Nuclear Information System (INIS)

    Russell, E.J.; Koslow, M.; Lasjaunias, P.; Bergeron, R.T.; Chase, N.

    1982-01-01

    Anatomical relationships of temporal bone structures are demonstrated by thin section edge detection computed tomography. Many otic structures are best appreciated in axial view, but reorientation to anatomy as seen in this plane is needed for optimal diagnosis. A level by level review of key structure is presented toward this end. The limitations and advantages of computed tomography are discussed. (orig.)

  18. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  19. Time-Domain Terahertz Computed Axial Tomography NDE System

    Science.gov (United States)

    Zimdars, David

    2012-01-01

    NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D

  20. Computed tomography scan based prediction of the vulnerable carotid plaque

    DEFF Research Database (Denmark)

    Diab, Hadi Mahmoud Haider; Rasmussen, Lars Melholt; Duvnjak, Stevo

    2017-01-01

    BACKGROUND: Primary to validate a commercial semi-automated computed tomography angiography (CTA) -software for vulnerable plaque detection compared to histology of carotid endarterectomy (CEA) specimens and secondary validating calcifications scores by in vivo CTA with ex vivo non......-contrast enhanced computed tomography (NCCT). METHODS: From January 2014 to October 2016 53 patients were included retrospectively, using a cross-sectional design. All patients underwent both CTA and CEA. Sixteen patients had their CEA specimen NCCT scanned. The semi-automated CTA software analyzed carotid stenosis...

  1. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    International Nuclear Information System (INIS)

    Marchiori, Edson; Irion, Klaus Loureiro; Zanetti, Glaucia; Missrie, Israel; Sato, Juliana

    2008-01-01

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  2. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Meirelles, Gustavo Souza Portes [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil); Irion, Klaus Loureiro [The Royal Liverpool University Hospital, Liverpool (United Kingdom); Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil); Missrie, Israel [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Diagnostico por Imagem; Sato, Juliana [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Otorrinolaringologia e Cirurgia de Cabeca e Pescoco

    2008-12-15

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  3. Measurements of computed tomography dose index for axial and spiral CT scanners

    International Nuclear Information System (INIS)

    Breiki, G; Abbas, Y.; Diab, H.M.; Gomaa, M

    2007-01-01

    The energy deposited in the patient by the rotating x-ray beam in computed tomography produces more uniform absorbed dose values within the section of imaged tissue than those produced in conventional radiological procedures. The dose values within a specific section are determined by factors such as voltage, current, scan field, rotation angle, filtration, collimation, and section thickness and spacing. This study is a part of extensive project, aiming to investigate practice of computed tomography at various hospitals and to implement a Reference Dose Levels (RDLs) to routine CT examinations in Egypt. The dosimetric quantities proposed in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDI w ) for a single slice and dose-length product (DLP) for a complete examination. Patient-related data as well as technical parameters for head, chest, abdomen and pelvis examinations were collected for seven CT scanners in public and private hospitals.Dose measurements were performed for both axial and spiral models for a range of CT examinations using CT dosimetry head and body phantoms, and ion chamber designed for CT dosimetry. The determined CTDI w and DLP values were compared with the European Commission reference dose levels (ECRDLs) and also with some international survey results. Mean values of CTDI w had a range of 36-69 m Gy with average 55 m Gy for head, and 11-35 mGy with average 23 mGy for chest, abdomen and pelvis examinations. The current reference CTDI w values are 60 m Gy for adult head and 25 m Gy for adult Abdomen

  4. Excessive lateral patellar translation on axial computed tomography indicates positive patellar J sign.

    Science.gov (United States)

    Xue, Zhe; Song, Guan-Yang; Liu, Xin; Zhang, Hui; Wu, Guan; Qian, Yi; Feng, Hua

    2018-03-20

    The purpose of the study was to quantify the patellar J sign using traditional computed tomography (CT) scans. Fifty-three patients (fifty-three knees) who suffered from recurrent patellar instability were included and analyzed. The patellar J sign was evaluated pre-operatively during active knee flexion and extension. It was defined as positive when there was obvious lateral patellar translation, and negative when there was not. The CT scans were performed in all patients with full knee extension; and the parameters including bisect offset index (BOI), patellar-trochlear-groove (PTG) distance, and patellar lateral tilt angle (PLTA) were measured on the axial slices. All the three parameters were compared between the J sign-positive group (study group) and the J sign-negative group (control group). In addition, the optimal thresholds of the three CT scan parameters for predicting the positive patellar J sign were determined with receiver operating characteristic (ROC) curves, and the diagnostic values were assessed by the area under the curve (AUC). Among the fifty-three patients (fifty-three knees), thirty-seven (70%) showed obvious lateral patellar translation, which were defined as positive J sign (study group), and the remaining sixteen (30%) who showed no lateral translation were defined as negative J sign (control group). The mean values of the three CT parameters in the study group were all significantly larger compared to the control group, including BOI (121 ± 28% vs 88 ± 12%, P = 0.038), PTG distance (5.2 ± 6.6 mm vs - 4.4 ± 5.2 mm, P J sign was 97.5% (Sensitivity = 83.3%, Specificity = 87.5%). In this study, the prevalence of positive patellar J sign was 70%. The BOI measured from the axial CT scans of the knee joint can be used as an appropriate predictor to differentiate the positive J sign from the negative J sign, highlighting that the excessive lateral patellar translation on axial CT scan indicates positive

  5. Identification of a unique cause of ring artifact seen in computed tomography trans-axial images

    International Nuclear Information System (INIS)

    Jha, Ashish Kumar; Purandare, Nilendu C; Shah, Sneha; Agrawal, Archi; Puranik, Ameya D; Rangarajan, Venkatesh

    2013-01-01

    Artifacts present in computed tomography (CT) image often degrade the image quality and ultimately, the diagnostic outcome. Ring artifact in trans-axial image is caused by either miscalibrated or defective detector element of detector row, which is often categorized as scanner based artifact. A ring artifact detected on trans-axial CT image of positron emission tomography/computed tomography (PET/CT), was caused by contamination of CT tube aperture by droplet of injectable contrast medium. This artifact was corrected by removal of contrast droplet from CT tube aperture. The ring artifact is a very common artifact, commonly cited in the literature. Our case puts forward an uncommon cause of this artifact and its method of correction, which also, has no mention in the existing literature

  6. Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans

    Science.gov (United States)

    2017-07-13

    Computed Tomography Scans by Autumn R Kulaga, Kathryn L Loftis, and Eric Murray Approved for public release; distribution is...Army Research Laboratory Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans by Autumn R Kulaga...Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  7. Dynamic computed tomography scanning of benign bone lesions: Preliminary results

    International Nuclear Information System (INIS)

    Levine, E.; Neff, J.R.

    1983-01-01

    The majority of benign bone lesions can be evaluated adequately using conventional radiologic techniques. However, it is not always possible to differentiate reliably between different types of benign bone lesions on the basis of plain film appearances alone. Dynamic computed tomography (CT) scanning provides a means for further characterizing such lesions by assessing their degree of vascularity. Thus, it may help in distinguishing an osteoid osteoma, which has a hypervascular nidus, from a Brodie's abscess, which is avascular. Dynamic CT scanning may also help in the differentiation between a fluid-containing simple bone cyst, which is avascular, and other solid or semi-solid benign bone lesions which slow varying degrees of vascularity. However, because of the additional irradiation involved, dynamic CT scanning should be reserved for evaluation of selected patients with benign bone lesions in whom the plain film findings are not definitive and in whom the CT findings may have a significant influence on management. (orig.)

  8. Osteotomy simulation and soft tissue prediction using computer tomography scans

    International Nuclear Information System (INIS)

    Teschner, M.; Girod, S.; Girod, B.

    1999-01-01

    In this paper, a system is presented that can be used to simulate osteotomies of the skull and to estimate the resulting of tissue changes. Thus, the three-dimensional, photorealistic, postoperative appearance of a patient can be assessed. The system is based on a computer tomography scan and a photorealistic laser scan of the patient's face. In order to predict the postoperative appearance of a patient the soft tissue must follow the movement of the underlying bone. In this paper, a multi-layer soft tissue model is proposed that is based on springs. It incorporates features like skin turgor, gravity and sliding bone contact. The prediction of soft tissue changes due to bone realignments is computed using a very efficient and robust optimization method. The system can handle individual patient data sets and has been tested with several clinical cases. (author)

  9. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  10. High-resolution computed tomography scan of lumbosacral spine

    International Nuclear Information System (INIS)

    Lifson, A.; Heithoff, K.B.; Burton, C.V.; Ray, C.D.

    1981-01-01

    A GE 8800 computed tomography (CT) scanner was used in over 4,000 cases of acute and chronic low back pain. Practically unlimited potentials of the study were clearly demonstrated in the diagnosis of such conditions as central and lateral spinal stenosis, overgrowth of fusions, disk herniation and free extrusion. Nonenhanced CT scanning is capable of clear visualization of soft-tissue structures: nerve roots and ganglia, epidural fat, epidural fibrous tissue, and epidural veins. CT scanning has become a primary diagnostic modality in the Low Back Clinic at our institute, replacing myelography in the majority of cases. Enhancement of the image with metrizamide was found to be of limited diagnostic value in lumbar degenerative disk disease. However, the utilization of a radiopaque material is indicated in selected circumstances. (Auth.)

  11. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  12. Computed tomography scan optimization using head phantom and radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P., E-mail: lorena.cfernandes@hotmail.com, E-mail: carlosvelcab@hotmail.com, E-mail: pridili@gmail.com, E-mail: apmourao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro de Imagem Molecular do INCT-Medicina Molecular (CIMol/UFMG) Belo Horizonte (Brazil); Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte (Brazil)

    2017-11-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  13. Computed tomography scan optimization using head phantom and radiochromic films

    International Nuclear Information System (INIS)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P.

    2017-01-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  14. Improving limited-projection-angle fluorescence molecular tomography using a co-registered x-ray computed tomography scan.

    Science.gov (United States)

    Radrich, Karin; Ale, Angelique; Ermolayev, Vladimir; Ntziachristos, Vasilis

    2012-12-01

    We examine the improvement in imaging performance, such as axial resolution and signal localization, when employing limited-projection-angle fluorescence molecular tomography (FMT) together with x-ray computed tomography (XCT) measurements versus stand-alone FMT. For this purpose, we employed living mice, bearing a spontaneous lung tumor model, and imaged them with FMT and XCT under identical geometrical conditions using fluorescent probes for cancer targeting. The XCT data was employed, herein, as structural prior information to guide the FMT reconstruction. Gold standard images were provided by fluorescence images of mouse cryoslices, providing the ground truth in fluorescence bio-distribution. Upon comparison of FMT images versus images reconstructed using hybrid FMT and XCT data, we demonstrate marked improvements in image accuracy. This work relates to currently disseminated FMT systems, using limited projection scans, and can be employed to enhance their performance.

  15. Determination of dosimetric quantities in pediatric abdominal computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Jornada, Tiago da Silva [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostipo por Imagem; Silva, Teogenes Augusto da, E-mail: silvata@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-09-15

    Objective: aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods: the study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results: No significant difference was observed in the values for weighted air kerma index (C{sub W}), but the differences were relevant in values for volumetric air kerma index (C{sub VOL}), air kerma-length product (P{sub KL,CT}) and effective dose. Conclusion: Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, P{sub KL,CT} and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. (author)

  16. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    Science.gov (United States)

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  17. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  18. Pathophysiological study of experimental hydrocephalus with computed tomography (CT) scan

    International Nuclear Information System (INIS)

    Murata, Takaho

    1980-01-01

    In order to investigate the pathophysiological changes during a development of hydrocephalus, the observations employing computed tomography (CT) scans and monitorings of intracranial epidural pressure (EDP) were performed in a series of kaolin-induced canine hydrocephalus. According to ''volume index'' of ventricles which was calculated from printed-out CT numbers, great individual variations were recognized in the degree of a ventricular enlargement as well as the rate of EDP. They are thought to be due to the difference in types of hydrocephalus, which have been induced by a discrepancy in the site and degree of an obstruction caused by kaolin. Periventricular lucency (PVL) of various degrees were also detected on CT scans of experimental hydrocephalus. It was always marked in the superolateral angle of frontal horn of the lateral ventricles, and differed in degree from severe to mild. PVLs were distinct in the acute stage with high EDP, and gradually became indistinct and had a tendency to disappear thereafter along with decreased EDP. They immediately disappeared after shunting operation. The pathogenesis of PVL was investigated with histological examinations, as well as by using contrast enhancement, Metrizamide ventriculography, the analysis of linear density profiles, and the measurement of regional cerebral blood flow (rCBF). Consequently, PVLs in hydrocephalus are considered to represent an acute edema or a chronic CSF retention in the periventricular white matter caused by increase of water content. In other words, they are regarded as a sign of present or preceding intraventricular hypertension on CT scan, and may become a clinical indication for shunting operation. (author)

  19. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  20. Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

    International Nuclear Information System (INIS)

    Dugas, Alexandre; Therasse, Éric; Kauffmann, Claude; Tang, An; Elkouri, Stephane; Nozza, Anna; Giroux, Marie-France; Oliva, Vincent L.; Soulez, Gilles

    2012-01-01

    Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland–Altman analysis. Results: Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001–0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662–0.780) and single-plane MPR images (0.772–0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.

  1. Dosimetric evaluation of cone beam computed tomography scanning protocols

    International Nuclear Information System (INIS)

    Soares, Maria Rosangela

    2015-01-01

    It was evaluated the cone beam computed tomography, CBCT scanning protocols, that was introduced in dental radiology at the end of the 1990's, and quickly became a fundamental examination for various procedures. Its main characteristic, the difference of medical CT is the beam shape. This study aimed to calculate the absorbed dose in eight tissues / organs of the head and neck, and to estimate the effective dose in 13 protocols and two techniques (stitched FOV e single FOV) of 5 equipment of different manufacturers of cone beam CT. For that purpose, a female anthropomorphic phantom was used, representing a default woman, in which were inserted thermoluminescent dosimeters at several points, representing organs / tissues with weighting values presented in the standard ICRP 103. The results were evaluated by comparing the dose according to the purpose of the tomographic image. Among the results, there is a difference up to 325% in the effective dose in relation to protocols with the same image goal. In relation to the image acquisition technique, the stitched FOV technique resulted in an effective dose of 5.3 times greater than the single FOV technique for protocols with the same image goal. In the individual contribution, the salivary glands are responsible for 31% of the effective dose in CT exams. The remaining tissues have also a significant contribution, 36%. The results drew attention to the need of estimating the effective dose in different equipment and protocols of the market, besides the knowledge of the radiation parameters and equipment manufacturing engineering to obtain the image. (author)

  2. Accuracy of a computed tomography scanning procedure to manufacture digital models.

    NARCIS (Netherlands)

    Darroudi, A.M.; Kuijpers-Jagtman, A.M.; Ongkosuwito, E.M.; Suttorp, C.M.; Bronkhorst, E.M.; Breuning, K.H.

    2017-01-01

    INTRODUCTION: Accurate articulation of the digital dental casts is crucial in orthodontic diagnosis and treatment planning. We aimed to determine the accuracy of manufacturing digital dental casts from computed tomography scanning of plaster casts regarding linear dimensions and interarch

  3. Ceftriaxone-associated pancreatitis captured on serial computed tomography scans

    Directory of Open Access Journals (Sweden)

    Nozomu Nakagawa, MD

    2018-02-01

    Full Text Available A 74-year-old man was treated with ceftriaxone for 5 days and subsequently experienced epigastric pain. Computed tomography (CT was performed 7 and 3 days before epigastralgia. Although the first CT image revealed no radiographic signs in his biliary system, the second CT image revealed dense radiopaque material in the gallbladder lumen. The third CT image, taken at symptom onset, showed high density in the common bile duct and enlargement of the pancreatic head. This is a very rare case of pseudolithiasis involving the common bile duct, as captured on a series of CT images.

  4. Ceftriaxone-associated pancreatitis captured on serial computed tomography scans.

    Science.gov (United States)

    Nakagawa, Nozomu; Ochi, Nobuaki; Yamane, Hiromichi; Honda, Yoshihiro; Nagasaki, Yasunari; Urata, Noriyo; Nakanishi, Hidekazu; Kawamoto, Hirofumi; Takigawa, Nagio

    2018-02-01

    A 74-year-old man was treated with ceftriaxone for 5 days and subsequently experienced epigastric pain. Computed tomography (CT) was performed 7 and 3 days before epigastralgia. Although the first CT image revealed no radiographic signs in his biliary system, the second CT image revealed dense radiopaque material in the gallbladder lumen. The third CT image, taken at symptom onset, showed high density in the common bile duct and enlargement of the pancreatic head. This is a very rare case of pseudolithiasis involving the common bile duct, as captured on a series of CT images.

  5. Methanol poisoning: brain computed tomography scan findings in four patients

    International Nuclear Information System (INIS)

    Patankar, T.; Prasad, S.; Rathod, K.; Bichile, L.; Karnad, D.

    1999-01-01

    Methanol, through its chief metabolite, formate, causes irreversible neurological damage. Methanol intoxication produces classic neuropathological changes and characteristic imaging findings. Computed tomography was performed on four patients who presented with a history of methanol poisoning. Prominent, hypodense lesions in the lentilform nuclei and peripheral white matter, sometimes with haemorrhage, were the characteristic imaging findings in the present patients. It was noted that the severity and extent of necrosis of the lentilform nuclei do not necessarily correlate with the clinical outcome. Copyright (1999) Blackwell Science Pty Ltd

  6. New possibilities of three-dimensional reconstruction of computed tomography scans

    International Nuclear Information System (INIS)

    Herman, M.; Tarjan, Z.; Pozzi-Mucelli, R.S.

    1996-01-01

    Three-dimensional (3D) computed tomography (CT) scan reconstructions provide impressive and illustrative images of various parts of the human body. Such images are reconstructed from a series of basic CT scans by dedicated software. The state of the art in 3D computed tomography is demonstrated with emphasis on the imaging of soft tissues. Examples are presented of imaging the craniofacial and maxillofacial complex, central nervous system, cardiovascular system, musculoskeletal system, gastrointestinal and urogenital systems, and respiratory system, and their potential in clinical practice is discussed. Although contributing no new essential diagnostic information against conventional CT scans, 3D scans can help in spatial orientation. 11 figs., 25 refs

  7. Use and impact of positron computed tomography scanning in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Mazziotta, J.C.; Engel, J. Jr.

    1984-01-01

    Through the effective combination of instrumentation, tracer kinetic principles, and radiopharmaceuticals, positron computed tomography (PET) allows for the analytic, noninvasive measurement of local tissue physiology in humans. A large number of studies have already been performed in patients with epilepsy using 18F-fluorodeoxyglucose (FDG) to measure local cerebral glucose utilization. In patients with complex partial epilepsy who are candidates for surgery, hypometabolic zones have been seen consistently (70%) in the interictal state. The complex anatomical and pathophysiological investigation of these hypometabolic zones is discussed. Ictal studies of patients with partial seizures have demonstrated a much more variable metabolic pattern which usually consists of hypermetabolism relative to baseline or interictal studies. Generalized epilepsy produced by electroconvulsive shock and petit mal epilepsy have been studied using FDG to estimate glucose metabolism.

  8. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    Science.gov (United States)

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  9. Tangential scanning of hardwood logs: developing an industrial computer tomography scanner

    Science.gov (United States)

    Nand K. Gupta; Daniel L. Schmoldt; Bruce Isaacson

    1999-01-01

    It is generally believed that noninvasive scanning of hardwood logs such as computer tomography (CT) scanning prior to initial breakdown will greatly improve the processing of logs into lumber. This belief, however, has not translated into rapid development and widespread installation of industrial CT scanners for log processing. The roadblock has been more operational...

  10. Deriving motion from megavoltage localization cone beam computed tomography scans

    International Nuclear Information System (INIS)

    Alfredo C Siochi, R

    2009-01-01

    Cone beam computed tomography (CBCT) projection data consist of views of a moving point (e.g. diaphragm apex). The point is selected in identification views of extreme motion (two inhale, two exhale). The room coordinates of the extreme points are determined by source-to-view ray tracing intersections. Projected to other views, these points become opposite corners of a motion-bounding box. The view coordinates of the point, relative to the box, are used to interpolate between extreme room coordinates. Along with the views' time stamps, this provides the point's room coordinates as a function of time. CBCT-derived trajectories of a tungsten pin, moving 3 cm cranio-caudally and 1 cm elsewhere, deviate from expected ones by at most 1.06 mm. When deviations from the ideal imaging geometry are considered, mean errors are less than 0.2 mm. While CBCT-derived cranio-caudal positions are insensitive to the choice of identification views, the bounding box determination requires view separations between 15 and 163 deg. Inhale views with the two largest amplitudes should be used, though corrections can account for different amplitudes. The information could be used to calibrate motion surrogates, adaptively define phase triggers immediately before gated radiotherapy and provide phase and amplitude sorting for 4D CBCT.

  11. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  12. Dosimetry study using head dummy in computed tomography scans

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Do Carmo S, P.; Prata M, A.

    2017-10-01

    The concern in the amounts of radiation doses deposited in the patients is still great because the computed tomography (CT) exams are currently the ones that reach the highest levels of radiation deposited in the population. Brazilian legislation regulates the levels of doses deposited in patients since it is limited to estimating a maximum amount, depending on the region of the body to be exposed. Therefore is necessary to determine the amount of dose that is deposited in patients depending on the routine protocols used in the radio diagnosis services and thus, propose an optimization of these under the principles referring to dose limitation, optimization of radiological protection and of course, the justification of the practices. Experiments were conducted to determine the dose profile for routine head exams in an adult patient, using a physical simulator object of polymethylmethacrylate (PMMA) in cylindrical format with 4 peripheral orifices and one central one. Strips of radiochromic film were introduced in each of the holes to record the dose profile in each region and thus determine the amount of dose deposited in the entire volume of the simulator object. A General Electric 64-channel tomograph, typical of the radiology service, was used for voltages of 80, 100 and 120 kV with a fixed current of 200 ma, finding dose levels between 6.24 and 23.73 mGy. Noise analysis of the images was performed, finding that all of them met the acceptable diagnostic parameters. An optimized protocol is proposed for head CT exams with a voltage of 80 kV for images with a noise index of 0.5%. (Author)

  13. A novel diagnostic method (spectral computed tomography of sacroiliac joints) for axial spondyloarthritis.

    Science.gov (United States)

    Zhang, Ping; Yu, Kai Hu; Guo, Rui Min; Ran, Jun; Liu, Yao; Morelli, John; Runge, Val M; Li, Xiao Ming

    2016-08-01

    To evaluate the diagnostic value of spectral computed tomography (CT) of sacroiliac joints for axial spondyloarthritis (SpA). We retrospectively analyzed the records of 125 patients with low back pain (LBP) suspected of having SpA. Each patient underwent sacroiliac joint spectral CT examination. Water- and calcium-based material decomposition images were reconstructed. After 3-6 months of follow-up, 76 were diagnosed with SpA, and the remaining 49 patients were diagnosed with nonspecific LBP (nLBP). The slope of sacroiliac bone marrow HU (Hounsfield unit) curve (λHU), CT value, and bone marrow to normal muscle ratios of water and calcium concentrations in the ilium and sacrum were calculated and compared between nLBP and SpA patients. The iliac λHU was 8.26 ± 3.91 for nLBP and 9.81 ± 4.92 for SpA. The mean iliac ratios of water and calcium concentrations were 1.04 ± 0.03 and 21.67 ± 4.40, respectively, for nLBP, and 1.07 ± 0.04 and 111.5 ± 358.98, respectively, for SpA. The mean iliac CT values were 311.12 ± 86.52 HU for nLBP and 423.97 ± 127.51 HU for SpA. There were statistically significant differences in iliac ratios of water and calcium concentrations, CT value, and λHU between nLBP and SpA patients (p sacroiliac joints of SpA patients. Copyright © 2015. Published by Elsevier B.V.

  14. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  15. Computer-Aided Detection of Kidney Tumor on Abdominal Computed Tomography Scans

    International Nuclear Information System (INIS)

    Kim, D.Y.; Park, J.W.

    2004-01-01

    Purpose: To implement a computer-aided detection system for kidney segmentation and kidney tumor detection on abdominal computed tomography (CT) scans. Material and Methods: Abdominal CT images were digitized with a film digitizer, and a gray-level threshold method was used to segment the kidney. Based on texture analysis performed on sample images of kidney tumors, a portion of the kidney tumor was selected as seed region for start point of the region-growing process. The average and standard deviations were used to detect the kidney tumor. Starting at the detected seed region, the region-growing method was used to segment the kidney tumor with intensity values used as an acceptance criterion for a homogeneous test. This test was performed to merge the neighboring region as kidney tumor boundary. These methods were applied on 156 transverse images of 12 cases of kidney tumors scanned using a G.E. Hispeed CT scanner and digitized with a Lumisys LS-40 film digitizer. Results: The computer-aided detection system resulted in a kidney tumor detection sensitivity of 85% and no false-positive findings. Conclusion: This computer-aided detection scheme was useful for kidney tumor detection and gave the characteristics of detected kidney tumors

  16. Use of routine computed tomography brain scanning of psychiatry patients

    International Nuclear Information System (INIS)

    Agzarian, M.J.; Chryssidis, S.; Davies, R.P.; Pozza, C.H.

    2006-01-01

    The aim of this study was to evaluate the usefulness of CT of the brain in patients presenting with a psychiatric condition without focal neurological signs. The reports of 397 consecutive CT brain scans of patients presenting to two acute tertiary hospital psychiatric services over a 2-year period were assessed retrospectively. Of the 397 patients, 241 had psychosis, 87 had depression, 44 had bipolar affective disorder, seven had alcohol dependence, five had dementia, and the remaining 13 had a variety of diagnoses including personality disorder and transient ischaemic attack. Findings on 377 (95%) of the CT scans showed no abnormality. Specific abnormalities were described in 20 (5%) of the CT scans. Three scans showed non-specific minor abnormalities, which, when followed up by MRI, showed no relevant abnormality. All the abnormalities shown on CT were considered to be clinically unrelated to the patient's psychiatric condition. In conclusion, the pretest probability of finding a space-occupying lesion or other pertinent abnormality in patients presenting with psychiatric illnesses in this retrospective study appears not to be greater than that of the general population. The outcome of this study could be implemented to develop a clinical pathway for limiting assessment by CT for possible organic pathology in acute psychiatric illness. Copyright (2006) Blackwell Science Pty Ltd

  17. Micro computed tomography (CT) scanned anatomical gateway to insect pest bioinformatics

    Science.gov (United States)

    An international collaboration to establish an interactive Digital Video Library for a Systems Biology Approach to study the Asian citrus Psyllid and psyllid genomics/proteomics interactions is demonstrated. Advances in micro-CT, digital computed tomography (CT) scan uses X-rays to make detailed pic...

  18. Integration of digital dental casts in cone-beam computed tomography scans

    NARCIS (Netherlands)

    Rangel, F.A.; Maal, T.J.J.; Berge, S.J.; Kuijpers-Jagtman, A.M.

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all

  19. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan

    NARCIS (Netherlands)

    Hassan, B.; Metska, M.E.; Özok, A.R.; van der Stelt, P.; Wesselink, P.R.

    2009-01-01

    Our aim was to compare the accuracy of cone beam computed tomography (CBCT) scans and periapical radiographs (PRs) in detecting vertical root fractures (VRFs) and to assess the influence of root canal filling (RCF) on fracture visibility. Eighty teeth were endodontically prepared and divided into

  20. 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?

    Science.gov (United States)

    Tseng, Yolanda D.; Wootton, Landon; Nyflot, Matthew; Apisarnthanarax, Smith; Rengan, Ramesh; Bloch, Charles; Sandison, George; St. James, Sara

    2018-01-01

    Four dimensional computed tomography (4DCT) scans are routinely used in radiation therapy to determine the internal treatment volume for targets that are moving (e.g. lung tumors). The use of these studies has allowed clinicians to create target volumes based upon the motion of the tumor during the imaging study. The purpose of this work is to determine if a target volume based on a single 4DCT scan at simulation is sufficient to capture thoracic motion. Phantom studies were performed to determine expected differences between volumes contoured on 4DCT scans and those on the evaluation CT scans (slow scans). Evaluation CT scans acquired during treatment of 11 patients were compared to the 4DCT scans used for treatment planning. The images were assessed to determine if the target remained within the target volume determined during the first 4DCT scan. A total of 55 slow scans were compared to the 11 planning 4DCT scans. Small differences were observed in phantom between the 4DCT volumes and the slow scan volumes, with a maximum of 2.9%, that can be attributed to minor differences in contouring and the ability of the 4DCT scan to adequately capture motion at the apex and base of the motion trajectory. Larger differences were observed in the patients studied, up to a maximum volume difference of 33.4%. These results demonstrate that a single 4DCT scan is not adequate to capture all thoracic motion throughout treatment.

  1. Role of Postmortem Multislice Computed Tomography Scan in Close Blunt Head Injury

    Directory of Open Access Journals (Sweden)

    Prijo Sidipratomo

    2014-08-01

    Full Text Available BACKGROUND: Conventional autopsy in Indonesia is not well accepted as it is contrary to religion and culture. New radiological imaging method such as multislice computed tomography (MSCT scan has potential to be a diagnostic tool in forensic pathology. The purpose of this study is to determine the ability of MSCT scan in finding abnormalities in close blunt head injury compared with autopsy. METHODS: This study used descriptive qualitative method. Postmortem cases in Department of Forensic Medicine and Radiology of Dr. Cipto Mangunkusumo Hospital were selected based on inclusion criteria. Then MSCT scan and autopsy were conducted. MSCT scan and autopsy results were compared and analyzed. RESULTS: There were 491 postmortem cases of blunt head injury. However, only 10 cases fulfilled inclusion criteria. Subarachnoid haemorrhages were identified 100% with MSCT scan and 80% with autopsy. Cerebral oedemas were identified 100% either with MSCT scan and autopsy. Subdural haemorrhages were identified 100% with MSCT scan, while 50% with autopsy. Multiple fractures were identified 80% with MSCT scan, while 40% with auto. CONCLUSIONS: MSCT scan showed a sensitive detection in finding abnormalities in close blunt head injury. Therefore it could be as an alternative choice of examination in close blunt head injury cases. KEYWORDS: multislice computed tomography scan, postmortem, blunt head injury, autopsy.

  2. Role of Postmortem Multislice Computed Tomography Scan in Close Blunt Head Injury

    OpenAIRE

    Sidipratomo, Prijo; Prija, Trijono Karmawan Sukana; Murtala, Bachtiar; Purwadianto, Agus; Lawrence, Gatot Susilo

    2014-01-01

    BACKGROUND: Conventional autopsy in Indonesia is not well accepted as it is contrary to religion and culture. New radiological imaging method such as multislice computed tomography (MSCT) scan has potential to be a diagnostic tool in forensic pathology. The purpose of this study is to determine the ability of MSCT scan in finding abnormalities in close blunt head injury compared with autopsy. METHODS: This study used descriptive qualitative method. Postmortem cases in Department of Forensic M...

  3. Integration of Digital Dental Casts in Cone-Beam Computed Tomography Scans

    OpenAIRE

    Rangel, Frits A.; Maal, Thomas J. J.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all reported methods have drawbacks. The aim of this feasibility study is to present a new simplified method to integrate digital dental casts into CBCT scans. In a patient scheduled for orthognathic ...

  4. Direct extraction of boundaries from computed tomography scans

    International Nuclear Information System (INIS)

    Thirion, J.P.

    1994-01-01

    This paper presents a method, based on the Filtered Backprojection technique (FBP), to extract directly the boundaries of X-ray images, without previous image reconstruction. The authors preprocess the raw data in order to compute directly the reconstructed values of the gradient or of the Laplacian at any location in the plane (defined with real coordinates). The reconstructed value of the gradient and of the Laplacian correspond to the exact mathematical definition of the differentials of the image. For noisy data, the authors propose also to use an extension of existing FBP techniques, adapted to the computation of the gradient and of the Laplacian. Finally, the authors show how to use the corresponding operators to perform the segmentation of a slice, without image reconstruction. Images of the reconstructed gradient, Laplacian, and segmented objects are presented

  5. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  6. [The importance of axial computer tomography of the neurocranium in neurotraumatology (1) (author's transl)].

    Science.gov (United States)

    Gustorf, R

    1979-07-01

    Computer tomography enables exact diagnostic clarification of intracranial lesions in trauma of the neurocranium. Subdural or epidural as well as intracerebral haemorrhages can be localised, and a circumscribed contusion and cerebral oedema become tangible. The article reports on 90 patients subjected to computerized tomography following trauma of the neurocranium. In about 50% of the cases, the trauma had been caused by a traffic accident. About 27% of the accident victims were children and adolescents. In about one-half of the examined persons, subdural or epidural haemorrhages were found, whereas in about 20% of the cases, contusions, partly with mild haemorrhages, were seen. In about 10% of the cases a more or less severe oedema was seen. About 20% of the patients yielded no abnormal finding by CT in accordance with the age of the patient.

  7. Design and application of the MARK IV scanning system for radionuclide computed tomography of the brain

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Hoffman, E.J.; Phelps, M.E.; Ricci, A.; Reivich, M.

    1976-01-01

    The MARK IV radioisotope scanning system was built to provide fast and accurate radionuclide computed tomography (RCT). It is designed primarily for detecting commonly available radioactive labels such as /sup 99m/Tc, but it is also adapted to detecting positron emitters such as 18 F. The system has interlaced convergent collimation in a 4-sided arrangement of 32-independent detectors which continuously rotate as a unit, detecting, processing, and displaying the reconstructed data while the study progresses

  8. Utility of computed axial tomography angiography in anatomic evaluation of pediatric patients with congenital heart diseases

    International Nuclear Information System (INIS)

    Mosquera, Walter A; Reyes P, Rafael; Aguilera N, Favio M; Breton, Cesar A; Buitrago, Danuby A; Suarez J Ramiro; Castillo, Victor

    2007-01-01

    Although echocardiogram and cardiac catheterization are used as first option tools for congenital heart diseases diagnosis, computed tomography angiography is a minimally invasive exam that through two to three dimensional images in real time gives an adequate approach to patients having this type of pathologies that require a rapid and precise evaluation of its extra cardiac anatomy. Objective: describe the institutional experience from August 2005 to August 2006 in the use of angiography by tomography as a complementary diagnostic method in the evaluation of pediatric patients with congenital heart diseases. Method: serial descriptive study. 58 pediatric patients with clinical and echocardiographic diagnosis of congenital heart diseases were evaluated through the General Electric Multislice Light peed/16 scanner. Results: 58 patients with history of congenital heart disease were evaluated through CT angiography. Mean age was 2.4 ± 4.03 years. Twenty (33.8%) had diagnosis of pulmonary atresia, four (6.7%) had tricuspid atresia, eight (13.5%,) had double-outlet right ventricle, seven (11.8%) had tetralogy of Fallot, nine (15.2%) had alterations of the aortic arch, seven (11.8%) had coarctation of the aorta two (3.3%) had interrupted aortic arch, six (10.3%) had persistent ductus arteriosus, four (6.7%) had anomalous venous drainage and three (5.1 %) had transposition of the great arteries. High quality images that allowed assessing the precise vascular anatomy were obtained. Conclusions: computed tomography angiography turned out to be a useful tool in the diagnostic approach of congenital heart diseases, because it allowed a tridimensional anatomic reconstruction. New studies that may permit the assessment of sensitivity, specificity and concordance level of this technique with other invasive diagnostic methods available for the diagnosis of this type of diseases, are required

  9. Diagnostic efficacy and pitfalls of a 64-raw multislice computed tomography scan for mild head injuries in children

    International Nuclear Information System (INIS)

    Matsumoto, Yoshihisa; Nawashiro, Hiroshi; Uozumi, Youichi

    2010-01-01

    The aim of this study is to analyze the usefulness of 64-raw multislice computed tomography (CT) scans and bone images of three-dimensional CT (3D-CT) scans for evaluation of mild head injuries in children. Thirteen children (9 boys and 4 girls, less than or equal to 15 years old) with mild head injury were included in the study. Head CT scans obtained within 24 hours after injury. All children had no episodes of loss of consciousness, amnesia, epilepsy, vomiting, and no neurological abnormality on arrival at hospital. We detected 9 positive findings on CT scans, which looked like fracture lines at the frontal bone in 7 cases. The bone images of CT axial views revealed a true fracture in one case in which a skull X-ray could not demonstrate a fracture line, but, other positive findings turned out to be a diploic vein surrounded by a thin bone cortex. All false positive findings were detected in the patients under the age of 6. By the 3D-reconstructive CT scan, it is easier to detect not only the intracranial lesions but also the cranial fracture. But, the diploic vein is apt to be misdiagnosed as the fracture line, especially in patients under the age of 6. (author)

  10. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    International Nuclear Information System (INIS)

    Tanaka, Hiroshi

    1988-01-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development. (author)

  11. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning, 2

    International Nuclear Information System (INIS)

    Uchiyama, Mayuki; Tanaka, Hiroshi; Harada, Junta

    1992-01-01

    Computed tomography was performed on 104 patients with cleft lip and palate by continuous 2 mm slice scanning. The type of hard palate was classified as normal, hypoplasia and aplasia, depending on its developmental degree. The shape of alveolus was also classified as circular, triangular and asymmetric forms for the evaluation of the maxillary development. The hard palate development correlated with the shape of the alveolus, the diameter of maxillary and mandibular bone, and frequency of sinusitis and otitis media. Evaluation of the hard palate by thin slice scanning is useful in presumption of future fecial development. (author)

  12. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiroshi

    1988-07-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development.

  13. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning, 2

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, Mayuki; Tanaka, Hiroshi; Harada, Junta (Jikei Univ., Tokyo (Japan). School of Medicine)

    1992-06-01

    Computed tomography was performed on 104 patients with cleft lip and palate by continuous 2 mm slice scanning. The type of hard palate was classified as normal, hypoplasia and aplasia, depending on its developmental degree. The shape of alveolus was also classified as circular, triangular and asymmetric forms for the evaluation of the maxillary development. The hard palate development correlated with the shape of the alveolus, the diameter of maxillary and mandibular bone, and frequency of sinusitis and otitis media. Evaluation of the hard palate by thin slice scanning is useful in presumption of future fecial development. (author).

  14. Axial Tomography from Digitized Real Time Radiography

    Science.gov (United States)

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  15. Volume adjustment of lung density by computed tomography scans in patients with emphysema

    DEFF Research Database (Denmark)

    Shaker, S B; Dirksen, A; Laursen, Lars Christian

    2004-01-01

    of pulmonary emphysema derived from CT scans. These parameters are markedly influenced by changes in the level of inspiration. The variability of lung density due to within-subject variation in TLV was explored by plotting TLV against PD and RA. RESULTS: The coefficients for volume adjustment for PD were...... relatively stable over a wide range from the 10th to the 80th percentile, whereas for RA the coefficients showed large variability especially in the lower range, which is the most relevant for quantitation of pulmonary emphysema. CONCLUSION: Volume adjustment is mandatory in repeated CT densitometry......PURPOSE: To determine how to adjust lung density measurements for the volume of the lung calculated from computed tomography (CT) scans in patients with emphysema. MATERIAL AND METHODS: Fifty patients with emphysema underwent 3 CT scans at 2-week intervals. The scans were analyzed with a software...

  16. Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, Nathalia Cristine; Junqueira, Jose Luiz Cinta; Panzarella, Francine Keuhi; Raitz, Ricardo [Sao Leopoldo Mandic Research Center, Dept. of Oral Radiology, College of Dentistry, Sao Paulo (Brazil); Brriviera, Mauricio [Dept. of Oral Radiology, College of Dentistry, Catholic University of Brasilia, Sao Paulo (Brazil)

    2017-03-15

    This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.

  17. Preoperative lymph-node staging of invasive urothelial bladder cancer with 18F-fluorodeoxyglucose positron emission tomography/computed axial tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jensen, Thor Knak; Holt, Per; Gerke, Oke

    2011-01-01

    OBJECTIVE: The treatment and prognosis of bladder cancer are based on the depth of primary tumour invasion and the presence of metastases. A highly accurate preoperative tumour, node, metastasis (TNM) staging is critical to proper patient management and treatment. This study retrospectively...... investigated the value of ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed axial tomography (¹⁸F-FDG PET/CT) and magnetic resonance imaging (MRI) for preoperative N staging of bladder cancer. Material and methods. From June 2006 to January 2008, 48 consecutive patients diagnosed with bladder......) for MRI and ¹⁸F-FDG PET/CT, respectively. The differences in specificity and negative predictive values were not statistically significant. Conclusions. No significant statistical difference between ¹⁸F-FDG PET/CT and MRI for preoperative N staging of urothelial bladder cancer was found in the study...

  18. Introduction of helical computed tomography affects patient selection for V/Q lung scan

    International Nuclear Information System (INIS)

    Zettinig, G.; Baudrexel, S.; Leitha, Th.

    2002-01-01

    Aim: Retrospective analysis for determination of the effect of helical computed tomography (HCT) on utilization of V/Q lung scanning to diagnose pulmonary embolism (PE) in a large general hospital. Methods: A total number of 2676 V/Q scans of in- and out-patients referred to our department between March 1992 and December 1998 and between April 1997 and December 1998 were analyzed by an identical group of nuclear physicians. Results: Neither the total number of annually performed V/Q scans (446 ± 135) nor the mean age of patients (56 years ± 17) changed significantly since the introduction of HCT. However, the referral pattern was different. The percentage of patients with high and intermediate probability for PE decreased significantly from 15.2% to 9.4% (p <0.01) and from 10.2% to 7.3% (p <0.05), respectively. Low probability scans significantly increased from 37.8% to 42.7% (p <0.05). The percentage of normal scans did not change significantly, however, there was a highly significant increase summarizing patients with normal and low probability scans (74.6% to 83.3%; p <0.01). Conclusion: The introduction of HCT affected the selection of patients referred for V/Q lung scanning since V/Q scanning was primarily used to exclude rather to confirm PE. (orig.)

  19. An electron beam linear scanning mode for industrial limited-angle nano-computed tomography

    Science.gov (United States)

    Wang, Chengxiang; Zeng, Li; Yu, Wei; Zhang, Lingli; Guo, Yumeng; Gong, Changcheng

    2018-01-01

    Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  3. Clinical Symptoms of Minor Head Trauma and Abnormal Computed Tomography Scan

    Directory of Open Access Journals (Sweden)

    Maghsoudi

    2015-11-01

    Full Text Available Background Minor head trauma accounts for 70% to 90% of all head traumas. Previous studies stated that minor head traumas were associated with 7% - 20% significant abnormal findings in brain computed tomography (CT-scans. Objectives The aim of this study was to reevaluate clinical criteria of taking brain CT scan in patients who suffered from minor head trauma. Patients and Methods We enrolled 680 patients presented to an academic trauma hospital with minor head trauma in a prospective manner. All participants underwent brain CT scan if they met the inclusion criteria and the results of scans were compared with clinical examination finding. Results Loss of consciousness (GCS drop or amnesia was markedly associated with abnormal brain CT scan (P < 0.05. Interestingly, we found 7 patients with normal clinical examination but significant abnormal brain CT scan. Conclusions According to the results of our study, we recommend that all patients with minor head trauma underwent brain CT scan in order not to miss any life-threatening head injuries.

  4. Comparison of 3D cellular imaging techniques based on scanned electron probes: Serial block face SEM vs. Axial bright-field STEM tomography.

    Science.gov (United States)

    McBride, E L; Rao, A; Zhang, G; Hoyne, J D; Calco, G N; Kuo, B C; He, Q; Prince, A A; Pokrovskaya, I D; Storrie, B; Sousa, A A; Aronova, M A; Leapman, R D

    2018-06-01

    Microscopies based on focused electron probes allow the cell biologist to image the 3D ultrastructure of eukaryotic cells and tissues extending over large volumes, thus providing new insight into the relationship between cellular architecture and function of organelles. Here we compare two such techniques: electron tomography in conjunction with axial bright-field scanning transmission electron microscopy (BF-STEM), and serial block face scanning electron microscopy (SBF-SEM). The advantages and limitations of each technique are illustrated by their application to determining the 3D ultrastructure of human blood platelets, by considering specimen geometry, specimen preparation, beam damage and image processing methods. Many features of the complex membranes composing the platelet organelles can be determined from both approaches, although STEM tomography offers a higher ∼3 nm isotropic pixel size, compared with ∼5 nm for SBF-SEM in the plane of the block face and ∼30 nm in the perpendicular direction. In this regard, we demonstrate that STEM tomography is advantageous for visualizing the platelet canalicular system, which consists of an interconnected network of narrow (∼50-100 nm) membranous cisternae. In contrast, SBF-SEM enables visualization of complete platelets, each of which extends ∼2 µm in minimum dimension, whereas BF-STEM tomography can typically only visualize approximately half of the platelet volume due to a rapid non-linear loss of signal in specimens of thickness greater than ∼1.5 µm. We also show that the limitations of each approach can be ameliorated by combining 3D and 2D measurements using a stereological approach. Copyright © 2018. Published by Elsevier Inc.

  5. Abdominal fat-evaluation by use of single scan computed tomography

    International Nuclear Information System (INIS)

    Jacobi, V.; Steinkamp, M.; Kirchner, J.; Fischer, H.; Diedrich, C.F.; Kollath, J.

    1997-01-01

    Purpose: Several studies emphasised the importance of the relationship between intraabdominal and total body adipose tissue as a risk factor for the development of metabolic or cardiovascular diseases. Therefore, the aim of the present study was to examine whether a single scan computed tomography is able to determine the whole intraabdominal fat volume with high accuracy and reproducibility. Materials and methods: Regions of interests (ROIs) were drawn manually for measuring intraabdominal fat in 51 unsuspicious abdominal CT. Results: The sexual differentiation of adipose tissue already described in a lot of studies could be confirmed in this study. Fat still predominates in females in lower half of the body (gynoid obesity). In men it predominates in the upper half (android obesity). Significant correlation concerning measuring the whole intraabdominal fat volume could be found in L1-level in women (r=0.992) and in L2-level in men (r=0.992). Measurement of a single scan enables us to assess whole intraabdominal fat volume due to a special formula. Conclusion: The determination of intraabdominal fat measured by a single scan computed tomography is a procedure associated with high accuracy and reproducibility. (orig.) [de

  6. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  7. X-ray detectors in axial computed tomography development; Sensori di radiazioni X negli sviluppi della tomografia assiale computerizzata

    Energy Technology Data Exchange (ETDEWEB)

    Gislon, R.; Imperiali, F. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Innovazione

    1996-12-01

    The increase of potentially of axial computed tomography as a non destructive investigation method in industrial field is particularly tied to the development of the X-rays detectors. The transition from the first gas ionization detectors to the last semiconductor detectors has indeed dramatically increased the performances of tomographic systems. In this report, after a quick analysis of fundamental principles of tomography, the most significant parameters for a detector to be used in a tomographic system are reviewed. The examination of the principal kinds of detectors that have been up to now used, with their working schemes, allows to delineate their characteristics and so to compare them with the ideal detector sketched above. The necessity of using high definition arrays brings to put into evidence the inadequacy of both gas and liquid ionization detectors and also of those types of light conversion devices which utilize for signal amplification a photomultiplier tube. Systems based on charge coupled devices or on a light conversion obtained with semiconductor photodiode arrays are definitely to be preferred. The progress of the last years in microelectronic technologies has brought great improvements in this field.

  8. What Can Computed Tomography Scans of the Thorax Show after Breast Surgery?

    Directory of Open Access Journals (Sweden)

    Afsaneh Alikhassi

    2016-06-01

    Full Text Available Background: Postoperative breast abnormalities after breast conserving surgery or modified radical mastectomy are frequently overlooked and inaccurately assessed or reported using multidetector computed tomography (MDCT. These inaccurate results may have legal ramifications for the clinicians, cause patients avoidable anxiety, and lead to additional unnecessary diagnostic follow-up testing and costs.Methods: The patients with a history of breast cancer who had undergone breast-conserving surgery or modified radical mastectomy up to 6 months prior to undergoing a thoracic MDCT scan consented and enrolled in this study. These patients underwent a thoracic MDCT scan either because of respiratory or cardiac clinical symptoms or as part of breast cancer staging.Results: Forty women were included in this study. Different postoperative breast changes observed on thoracic MDCT scans including fibrous scar tissue, fat necrosis, seroma, abscess, hematoma, and recurrent and residual tumor were described.Conclusions: MDCT scans offer sufficient evidence in many postoperative cases to allow a confident diagnosis. General radiologists who review thoracic MDCT scans should know how to characterize breast lesions incidentally found on MDCT scans after breast surgeries. This information would enhance the value of the radiologist’s report for appropriate case management.

  9. Integration of Digital Dental Casts in Cone-Beam Computed Tomography Scans

    Science.gov (United States)

    Rangel, Frits A.; Maal, Thomas J. J.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all reported methods have drawbacks. The aim of this feasibility study is to present a new simplified method to integrate digital dental casts into CBCT scans. In a patient scheduled for orthognathic surgery, titanium markers were glued to the gingiva. Next, a CBCT scan and dental impressions were made. During the impression-taking procedure, the titanium markers were transferred to the impression. The impressions were scanned, and all CBCT datasets were exported in DICOM format. The two datasets were matched, and the dentition derived from the scanned impressions was transferred to the CBCT of the patient. After matching the two datasets, the average distance between the corresponding markers was 0.1 mm. This novel method allows for the integration of digital dental casts into CBCT scans, overcoming problems such as unwanted extra radiation exposure, distortion of soft tissues due to the use of bite jigs, and time-consuming digital data handling. PMID:23050159

  10. Estimation of MSAD values in computed tomography scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno Beraldo; Teogenes Augusto da, E-mail: bbo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Mourao, Arnaldo Prata [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2013-03-15

    Objective: To evaluate the feasibility of using radiochromic films as an alternative dosimeter to estimate the multiple scan average dose on the basis on kerma profiles. Materials and Methods: The radiochromic films were distributed in cylinders positioned in the center and in four peripheral bores of a standard abdominal phantom utilized for computed tomography dosimetry. Results: Values for multiple scan average dose values corresponded to 13.6 {+-} 0.7, 13.5 {+-} 0.7 and 18.7 {+-} 1.0 mGy for pitch of 0.75, 1.00 and 1.50, respectively. Conclusion: In spite of results showing lower values than the reference level for radiodiagnosis (25 mGy) established by the Brazilian regulations for abdominal studies, it is suggested that there is room to optimize procedures and review the reference level for radiodiagnosis in Brazil. (author)

  11. Comparison of radionuclide scans with computer-assisted tomography in diagnosis of intracranial disease

    International Nuclear Information System (INIS)

    Clifford, J.R.; Connolly, E.S.; Voorhies, R.M.

    1976-01-01

    Radionuclide brain scans were compared with computer-assisted tomography (CAT) for the diagnosis of intracranial disorders in 297 patients. The diagnosis was confirmed in 281 patients who formed the population for the study. The radionuclide scan was false positive for 12 patients (3.9 percent) and false negative for eight (2.6 percent). The CAT was false positive for three patients (1 percent) and false negative for one (0.3 percent). In the 133 patients in whom both tests were negative, no evidence of central nervous system pathology has been found during the 6 to 18 month follow-up. Brain tumors and intracerebral hemorrhage are more readily detectable with CAT

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  13. Underdiagnosis of Vertebral Collapse on Routine Multidetector Computed Tomography Scan of the Abdomen

    International Nuclear Information System (INIS)

    Obaid, H.; Husamaldin, Z.; Bhatt, R.

    2008-01-01

    Background: Vertebral fractures are commonly associated with osteoporosis and have significant morbidity and mortality rates. Osteoporotic vertebral fractures are presently considered as a treatable and preventable condition, and early detection is vital for further management. The evaluation of vertebral compression on multidetector computed tomography (MDCT) scans of the abdomen has, to our knowledge, not been reported before. Purpose: To assess the prevalence of vertebral collapse on routine abdominal CT scans, and to evaluate the usefulness of the multiplanar reconstruction (MPR) capability of MDCT scans in accurately identifying vertebral abnormalities such as vertebral collapse, spondylolisthesis, and retrolisthesis. Material and Methods: A retrospective review of 307 MDCT scans of the abdomen was carried out at a university teaching hospital. Identifiable patient information was anonymized for data protection. All images were reviewed on a picture archiving and communications system (PACS) using sagittal MPR and bone window for the assessment of the vertebrae. Data were collected from the Computerized Radiology Information System (CRIS). Results: Vertebral collapse was seen in 42 (13.6%) of the 307 patients undergoing routine MDCT of the abdomen. Multilevel and single-level collapses were seen in 24 and 18 patients, respectively. Spondylolisthesis was identified in 5.5% (n=17), and retrolisthesis was seen in 0.6% (n=2). All patients with vertebral fracture were older than 50 years. Women were more commonly affected than men. Conclusion: A significant number of patients with vertebral collapse were diagnosed using MPR on MDCT routine scans of the abdomen

  14. Application of the axial tomography computed for the detection of bags of dampness in dry wood of Gmelina arborea (Roxb.)

    International Nuclear Information System (INIS)

    Moya R, Roger; Munoz A, Freddy; Escalante, Ivan

    2006-01-01

    Gmelina arborea (Roxb.) is widely used for commercial reforestation in Costa Rica due to its excellent growth rate and productivity. However, during the lumber drying process, the wooden boards show non-uniform values of final moisture content (MC). The low uniformity in final MC is caused by the presence of wet pockets, originated during the growing process of the tree. The regions with wet pockets present zones with a high MC, which are hard to detect with traditional methods for MC measurements during the wood drying process. It is possible to detect and to set the limits of the presence of wet wood in Gmelina arborea boards using scanning computed tomography (CT-scanning), a technique applied in medical diagnostic. A board with wet pockets is shown in the CT-scanning images in clear color and with low values of the Hounsfield Unit (HU) or CT number. When these values were transformed to wood density, it was determined that wet pockets were in a density of around 190 kg/m 3 , a value higher than normal wood. Also, it was possible to observe growth tree rings in the CT-scanning images, an important feature for dendrochronological research. The obtained results allowed showing that it is possible to apply this technique in the process of lumber production, to detect the zones with high MC in kiln dried Gmelina arborea wood. (author) [es

  15. Guided access cavity preparation using cone-beam computed tomography and optical surface scans - an ex vivo study

    DEFF Research Database (Denmark)

    Buchgreitz, J; Buchgreitz, M; Mortensen, D

    2016-01-01

    AIM: To evaluate ex vivo, the accuracy of a preparation procedure planned for teeth with pulp canal obliteration (PCO) using a guide rail concept based on a cone-beam computed tomography (CBCT) scan merged with an optical surface scan. METHODOLOGY: A total of 48 teeth were mounted in acrylic bloc...

  16. Frequent Computed Tomography Scanning Due to Incomplete Three-View X-Ray Imaging of the Cervical Spine

    NARCIS (Netherlands)

    Saltzherr, Teun Peter; Beenen, Ludo F. M.; Reitsma, Johannes B.; Luitse, Jan S. K.; Vandertop, W. Peter; Goslings, J. Carel

    2010-01-01

    Background: Conventional C-spine imaging (3-view series) is still widely used in trauma patients, although the utilization of computed tomography (CT) scanning is increasing. The aim of this study was to analyze the value of conventional radiography and the frequency of subsequent CT scanning due to

  17. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane.

    Science.gov (United States)

    Kim, Ji-Beom; Yi, Young; Kim, Jae-Young; Cho, Jae-Ho; Kwon, Min-Soo; Choi, Seung-Hyuk; Lee, Woo-Chun

    2017-08-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis.

  18. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Beom; Yi, Young; Lee, Woo-Chun [Seoul Foot and Ankle Center, Dubalo Orthopaedic Clinic, Seochogu, Seoul (Korea, Republic of); Kim, Jae-Young; Kwon, Min-Soo; Choi, Seung-Hyuk [Inje University Seoul Paik Hospital, Department of Orthopaedic Surgery, Jung-gu, Seoul (Korea, Republic of); Cho, Jae-Ho [Hallym University, ChunCheon Sacred Heart Hospital, Department of Orthopaedic Surgery, Chuncheon, GangWon-do (Korea, Republic of)

    2017-08-15

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis. (orig.)

  19. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane

    International Nuclear Information System (INIS)

    Kim, Ji-Beom; Yi, Young; Lee, Woo-Chun; Kim, Jae-Young; Kwon, Min-Soo; Choi, Seung-Hyuk; Cho, Jae-Ho

    2017-01-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis. (orig.)

  20. Volume Adjustment of Lung Density by Computed Tomography Scans in Patients with Emphysema

    International Nuclear Information System (INIS)

    Shaker, S.B.; Dirksen, A.; Laursen, L.C.; Skovgaard, L.T.; Holstein-Rathlou, N.H.

    2004-01-01

    Purpose: To determine how to adjust lung density measurements for the volume of the lung calculated from computed tomography (CT) scans in patients with emphysema. Material and Methods: Fifty patients with emphysema underwent 3 CT scans at 2-week intervals. The scans were analyzed with a software package that detected the lung in contiguous images and subsequently generated a histogram of the pixel attenuation values. The total lung volume (TLV), lung weight, percentile density (PD), and relative area of emphysema (RA) were calculated from this histogram. RA and PD are commonly applied measures of pulmonary emphysema derived from CT scans. These parameters are markedly influenced by changes in the level of inspiration. The variability of lung density due to within-subject variation in TLV was explored by plotting TLV against PD and RA. Results: The coefficients for volume adjustment for PD were relatively stable over a wide range from the 10th to the 80th percentile, whereas for RA the coefficients showed large variability especially in the lower range, which is the most relevant for quantitation of pulmonary emphysema. Conclusion: Volume adjustment is mandatory in repeated CT densitometry and is more robust for PD than for RA. Therefore, PD seems more suitable for monitoring the progression of emphysema

  1. Glycosaminoglycan, computed tomography and gallium-67 scanning in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Nakano, Takashi; Fujii, Junji; Yamakawa, Kiyohiro; Tamura, Shinsuke; Amuro, Yoshiki; Nabeshima, Kenji; Hada, Toshikazu; Higashino, Kazuya; Horai, Takeshi.

    1985-01-01

    Malignant pleural mesothelioma is an unusual disease, often difficult to diagnose. This paper describes the results of quantitative studies on glycosaminoglycan (GAG) in tumor tissues and the findings of chest computed tomography (CT) and gallium-67 scanning in 5 malignant pleural mesotheliomas. The total amount of GAG in tumor tissue was 2.3 to 17.0 times as high as that in adenocarcinoma of the lung. The amount of hyaluronic acid was 3.5 to 170 times higher than that in adenocarcinoma. Also, the amount of chondroitin sulfate increased 2.6 to 10.0 times, but there were no changes in dermatan sulfate and heparan sulfate contents in this neoplasm when compared with adenocarcinoma. The present study suggests that a marked increase of the total amount of GAG and elevation of either hyaluronic acid and chondroitin sulfate content or both is a characteristic abnormality in this neoplasm. In most cases, CT scan of the chest showed pleural effusion, irregular pleural tumorous thickening surrounding the whole lung surface and extension into the fissure. In 3 cases, tumorous lesions extending into the chest wall at the site of pleural biopsy could be visualized on CT. In the terminal stage, the thoracic cavity was occupied by tumor tissues. Gallium-67 scanning showed a diffusely increased radionuclide accumulation over the involved hemithorax with or without particular intensity in the periphery. Conversely, identification of these characteristic findings of CT and gallium-67 scanning indicates the possibility of malignant pleural mesothelioma. (author)

  2. Real-time axial motion detection and correction for single photon emission computed tomography using a linear prediction filter

    International Nuclear Information System (INIS)

    Saba, V.; Setayeshi, S.; Ghannadi-Maragheh, M.

    2011-01-01

    We have developed an algorithm for real-time detection and complete correction of the patient motion effects during single photon emission computed tomography. The algorithm is based on a linear prediction filter (LPC). The new prediction of projection data algorithm (PPDA) detects most motions-such as those of the head, legs, and hands-using comparison of the predicted and measured frame data. When the data acquisition for a specific frame is completed, the accuracy of the acquired data is evaluated by the PPDA. If patient motion is detected, the scanning procedure is stopped. After the patient rests in his or her true position, data acquisition is repeated only for the corrupted frame and the scanning procedure is continued. Various experimental data were used to validate the motion detection algorithm; on the whole, the proposed method was tested with approximately 100 test cases. The PPDA shows promising results. Using the PPDA enables us to prevent the scanner from collecting disturbed data during the scan and replaces them with motion-free data by real-time rescanning for the corrupted frames. As a result, the effects of patient motion is corrected in real time. (author)

  3. Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Capunay, C.; Carrascosa, P.; Vallejos, J.; Deviggiano, A.; Pollono, P.M.; Garcia, M.J.

    2011-01-01

    Objective. To determine the imaging quality and effective radiation dose (ERD) of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCTCA) compared to retrospective ECG-gating (RMDCT-CA). Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n=45) and without (n=45) tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver variability was k=0.92 (95 % CI: 0.87-0.96). The ERD (mean ± SD) using PMDCT-CA was 2.88 ± 0.37 mSv compared to 10.50 ± 1.15 mSv (p [es

  4. Investigation of optimal scanning protocol for X-ray computed tomography polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Sellakumar, P. [Bangalore Institute of Oncology, 44-45/2, II Cross, RRMR Extension, Bangalore 560 027 (India)], E-mail: psellakumar@rediffmail.com; James Jebaseelan Samuel, E. [School of Science and Humanities, VIT University, Vellore 632 014 (India); Supe, Sanjay S. [Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Hosur Road, Bangalore 560 027 (India)

    2007-11-15

    X-ray computed tomography is one of the potential tool used to evaluate the polymer gel dosimeters in three dimensions. The purpose of this study is to investigate the factors which affect the image noise for X-ray CT polymer gel dosimetry. A cylindrical water filled phantom was imaged with single slice Siemens Somatom Emotion CT scanner. The imaging parameters like tube voltage, tube current, slice scan time, slice thickness and reconstruction algorithm were varied independently to study the dependence of noise on each other. Reductions of noise with number of images to be averaged and spatial uniformity of the image were also investigated. Normoxic polymer gel PAGAT was manufactured and irradiated using Siemens Primus linear accelerator. The radiation induced change in CT number was evaluated using X-ray CT scanner. From this study it is clear that image noise is reduced with increase in tube voltage, tube current, slice scan time, slice thickness and also reduced with increasing the number of images averaged. However to reduce the tube load and total scan time, it was concluded that tube voltage of 130 kV, tube current of 200 mA, scan time of 1.5 s, slice thickness of 3 mm for high dose gradient and 5 mm for low dose gradient were optimal scanning protocols for this scanner. Optimum number of images to be averaged was concluded to be 25 for X-ray CT polymer gel dosimetry. Choice of reconstruction algorithm was also critical. From the study it is also clear that CT number increase with imaging tube voltage and shows the energy dependency of polymer gel dosimeter. Hence for evaluation of polymer gel dosimeters with X-ray CT scanner needs the optimization of scanning protocols to reduce the image noise.

  5. Feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in lung cancer treatment planning

    International Nuclear Information System (INIS)

    Xiao Jianghong; Zhang Hong; Gong Youling; Fu Yuchuan; Tang Bin; Wang Shichao; Jiang Qingfeng; Li Ping

    2010-01-01

    Background and purpose: To investigate the feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in 3-dimensional conformal radiotherapy (3D-CRT), stereotactic body radiation therapy (SBRT) and intensity-modulated radiotherapy (IMRT) treatment planning for lung cancers, respectively. Materials and methods: Twelve patients with bulky lung tumors and 14 patients with small lung tumors were retrospectively analyzed. Each patient took two sets of CT in the same position with active breathing control (ABC) technique before and after intravenous contrast agent (CA) injections. Bulky tumors were planned with 3D-CRT, while SBRT plans were generated for patients with small tumors based on CT scans with intravenous CA. In addition, IMRT plans were generated for patients with bulky tumors to continue on a planning study. All plans were copied and replaced on the scans without intravenous CA. The radiation doses calculated from the two sets of CTs were compared with regard to planning volumes (PTV), the organ at-risk (OAR) and the lungs using Wilcoxon's signed rank test. Results: In comparisons for 3D-CRT plans, CT scans with intravenous CA reduced the mean dose and the maximum dose of PTV with significant differences (p 95 ) for targets, respectively (p < 0.05). There was no statistical significance for lung parameters between two sets of scans in SBRT plans and IMRT plans. Conclusions: The enhanced CT scans can be used for both target delineation and treatment planning in 3D-CRT. The dose difference caused by intravenous CA is small. But for SBRT and IMRT, the minimum irradiation dose in targets may be estimated to be increased up to 2.71% while the maximum dose may be estimated to be decreased up to 1.36%. However, the difference in dose distribution in most cases were found to be clinical tolerable.

  6. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  7. Endoscopic ultrasonography and computed tomography scanning for preoperative staging of colonic cancer

    DEFF Research Database (Denmark)

    Malmstrøm, M L; Gögenur, I; Riis, L B

    2017-01-01

    PURPOSE: With an increasing demand for more accurate preoperative staging methods for colon cancer, we aimed to compare preoperative tumour (T)- and nodal (N)-stage in patients with left-sided colon cancer by endoscopic ultrasonography (EUS) and computed tomography (CT) with post......-operative histology as gold standard. METHODS: A total of 44 patients were prospectively recruited at Herlev and Roskilde University Hospitals during November 2014-January 2016. Thirty-five patients were included in the final analysis and underwent EUS, CT and surgery within 2 weeks. Diagnostic values were evaluated...... difficult to evaluate due to small patient numbers. EUS could be considered as a supplement to CT scans in selecting patients for neoadjuvant therapies, or local transmural treatment, in the future. TRIAL REGISTRATION: NCT02324023....

  8. Collateral findings during computed tomography scan for atrial fibrillation ablation: Let's take a look around.

    Science.gov (United States)

    Perna, Francesco; Casella, Michela; Narducci, Maria Lucia; Dello Russo, Antonio; Bencardino, Gianluigi; Pontone, Gianluca; Pelargonio, Gemma; Andreini, Daniele; Vitulano, Nicola; Pizzamiglio, Francesca; Conte, Edoardo; Crea, Filippo; Tondo, Claudio

    2016-04-26

    The growing number of atrial fibrillation catheter ablation procedures warranted the development of advanced cardiac mapping techniques, such as image integration between electroanatomical map and cardiac computed tomography. While scanning the chest before catheter ablation, it is frequent to detect cardiac and extracardiac collateral findings. Most collateral findings are promptly recognized as benign and do not require further attention. However, sometimes clinically relevant collateral findings are detected, which often warrant extra diagnostic examinations or even invasive procedure, and sometimes need to be followed-up over time. Even though reporting and further investigating collateral findings has not shown a clear survival benefit, almost all the working groups providing data on collateral findings reported some collateral findings eventually coming out to be malignancies, sometimes at an early stage. Therefore, there is currently no clear agreement about the right strategy to be followed.

  9. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  10. Prediction of intramuscular fat levels in Texel lamb loins using X-ray computed tomography scanning.

    Science.gov (United States)

    Clelland, N; Bunger, L; McLean, K A; Conington, J; Maltin, C; Knott, S; Lambe, N R

    2014-10-01

    For the consumer, tenderness, juiciness and flavour are often described as the most important factors for meat eating quality, all of which have a close association with intramuscular fat (IMF). X-ray computed tomography (CT) can measure fat, muscle and bone volumes and weights, in vivo in sheep and CT predictions of carcass composition have been used in UK sheep breeding programmes over the last few decades. This study aimed to determine the most accurate combination of CT variables to predict IMF percentage of M. longissimus lumborum in Texel lambs. As expected, predicted carcass fat alone accounted for a moderate amount of the variation (R(2)=0.51) in IMF. Prediction accuracies were significantly improved (Adj R(2)>0.65) using information on fat and muscle densities measured from three CT reference scans, showing that CT can provide an accurate prediction of IMF in the loin of purebred Texel sheep. Copyright © 2014. Published by Elsevier Ltd.

  11. Image interpolation allows accurate quantitative bone morphometry in registered micro-computed tomography scans.

    Science.gov (United States)

    Schulte, Friederike A; Lambers, Floor M; Mueller, Thomas L; Stauber, Martin; Müller, Ralph

    2014-04-01

    Time-lapsed in vivo micro-computed tomography is a powerful tool to analyse longitudinal changes in the bone micro-architecture. Registration can overcome problems associated with spatial misalignment between scans; however, it requires image interpolation which might affect the outcome of a subsequent bone morphometric analysis. The impact of the interpolation error itself, though, has not been quantified to date. Therefore, the purpose of this ex vivo study was to elaborate the effect of different interpolator schemes [nearest neighbour, tri-linear and B-spline (BSP)] on bone morphometric indices. None of the interpolator schemes led to significant differences between interpolated and non-interpolated images, with the lowest interpolation error found for BSPs (1.4%). Furthermore, depending on the interpolator, the processing order of registration, Gaussian filtration and binarisation played a role. Independent from the interpolator, the present findings suggest that the evaluation of bone morphometry should be done with images registered using greyscale information.

  12. Internal structure of a vermicular ironstone as determined by X-ray computed tomography scanning

    Energy Technology Data Exchange (ETDEWEB)

    Zinn, Yuri Lopes, E-mail: ylzinn@dcs.ufla.br [Universidade Federal de Lavras (UFLA), Lavras, MG (Brazil). Departamento de Ciencia do Solo; Carducci, Carla Eloize [Universidade Federal de Santa Catarina (UFSC), Curitibanos, SC (Brazil). Departamento de Agronomia; Araujo, Marla Alessandra [Universidade Federal de Lavras (UFLA), Lavras, MG (Brazil). Programa de Pos-graduacao em Ciencia do Solo

    2015-03-15

    Ironstones or petroplinthites are common materials in soils under humid tropical climate, generally defined as the result of Fe oxide accumulation in areas where the water table oscillates, and may exhibit considerable morphological variability. The aim of this study was to examine the internal structure and porosity of an ironstone fragment from a Petroferric Acrudox in Minas Gerais, Brazil, by computed tomography (CT) and conventional techniques. The sample analyzed had total porosity of 59.5 %, with large macropores in the form of tubular channels and irregular vughs, the latter with variable degrees of infilling by material released from the ironstone walls or the soil matrix. The CT scan also showed that the ironstone has wide variation in the density of the solid phase, most likely due to higher concentrations or thick intergrowths of hematite and magnetite/maghemite, especially in its outer rims. The implications of these results for water retention and soil formation in ironstone environments are briefly discussed. (author)

  13. A postmortem correlation of computer tomography and ultrasound scans of periventricular hemorrhage in preterm infants

    International Nuclear Information System (INIS)

    Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Yushiro; Nishimi, Toshihiro; Utsunomiya, Hidetsuna; Nakamura, Yasuhiro; Okudera, Toshio

    1988-01-01

    From January 1984 through September 1987, ultrasound scanning (US), computed tomography (CT), and autopy have been performed in 80 consecutive premature infants. Intracranial lesions consisted of intraventricular hemorrhage (IVH, n = 61), subarachnoid hemorrhage (SAH, n = 63), cerebellar hemorrhage (n = 5), hydrocephalus (n = 8), periventricular leukoencephalomalacia (n = 20), and anoxic encephalopathy (n = 40). Using autopsy findings as the standard, both US and CT had an accuracy of 80 % or more in detecting subependymal hemorrhage (SEH), IVH, dilated ventricle, and parenchymal hemorrhage ; however, both imaging modalities showed a high false negative for SAH (77 % for US vs 55 % for CT). Accuracy of US and CT was 82 % vs 72 % for SEH, and 72 % vs 85 % for IVH. High false positive and false negative rates, in spite of 80 % or more accuracy of imaging modalities, warrant further studies to obtain higher accuracy in the diagnosis of intracranial lesions. (Namekawa, K.)

  14. Postmortem correlation of computer tomography and ultrasound scans of periventricular hemorrhage in preterm infants

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Yushiro; Nishimi, Toshihiro; Utsunomiya, Hidetsuna; Nakamura, Yasuhiro; Okudera, Toshio

    1988-08-01

    From January 1984 through September 1987, ultrasound scanning (US), computed tomography (CT), and autopy have been performed in 80 consecutive premature infants. Intracranial lesions consisted of intraventricular hemorrhage (IVH, n = 61), subarachnoid hemorrhage (SAH, n = 63), cerebellar hemorrhage (n = 5), hydrocephalus (n = 8), periventricular leukoencephalomalacia (n = 20), and anoxic encephalopathy (n = 40). Using autopsy findings as the standard, both US and CT had an accuracy of 80 % or more in detecting subependymal hemorrhage (SEH), IVH, dilated ventricle, and parenchymal hemorrhage ; however, both imaging modalities showed a high false negative for SAH (77 % for US vs 55 % for CT). Accuracy of US and CT was 82 % vs 72 % for SEH, and 72 % vs 85 % for IVH. High false positive and false negative rates, in spite of 80 % or more accuracy of imaging modalities, warrant further studies to obtain higher accuracy in the diagnosis of intracranial lesions. (Namekawa, K.).

  15. Computer aided detection system for lung cancer using computer tomography scans

    Science.gov (United States)

    Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.

    2018-04-01

    Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.

  16. Low-dose computed tomography image restoration using previous normal-dose scan

    International Nuclear Information System (INIS)

    Ma, Jianhua; Huang, Jing; Feng, Qianjin; Zhang, Hua; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2011-01-01

    Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use

  17. Abdominal computed tomography scan as a screening tool in blunt trauma

    International Nuclear Information System (INIS)

    Brasel, K.J.; Borgstrom, D.C.; Kolewe, K.A.

    1997-01-01

    Background. One of the most difficult problems in blunt trauma is evaluation for potential intraabdominal injury. Admission for serial abdominal exams remains the standard of care after intraabdominal injury has been initially excluded. We hypothesized a normal abdominal computed tomography (CT) scan in a subgroup of minimally injured patients would obviate admission for serial abdominal examinations, allowing safe discharge from the emergency department (ED). Methods. We reviewed our blunt trauma experience with patients admitted solely for serial abdominal examinations after a normal CT. Patients were identified from the trauma registry at a Level 1 trauma center from July 1991 through June 1995. Patients with abnormal CTs, extra-abdominal injuries necessitating admission, hemodynamic abnormalities, a Glasgow Coma Scale less than 13, or injury severity scores (ISSs) greater than 15 were excluded. Records of 238 patients remained; we reviewed them to determine the presence of missed abdominal injury. Results. None of the 238 patients had a missed abdominal injury. Average ISS of these patients was 3.2 (range, 0 to 10). Discharging these patients from the ED would result in a yearly cost savings of $32,874 to our medical system. Conclusions. Abdominal CT scan is a safe and cost-effective screening tool in patients with blunt trauma. A normal CT scan in minimally injured patients allows safe discharge from the ED. (authors)

  18. Does high-power computed tomography scanning equipment affect the operation of pacemakers?

    International Nuclear Information System (INIS)

    Yamaji, Satoshi; Imai, Shinobu; Saito, Fumio; Yagi, Hiroshi; Kushiro, Toshio; Uchiyama, Takahisa

    2006-01-01

    Computed tomography (CT) is widely used in clinical practice, but there has not been a detailed report of its effect on the functioning of pacemakers. During CT, ECGs were recorded in 11 patients with pacemakers and the electromagnetic field in the CT room was also measured. The effect of CT on a pacemaker was also investigated in a human body model with and without shielding by rubber or lead. Transient malfunctions of pacemakers during CT occurred in 6 of 11 patients. The model showed that malfunctioning of the pacemaker was induced by CT scanning and this was prevented by lead but not by rubber. The alternating electrical field was 150 V/m on the CT scanning line, which was lower than the level influencing pacemaker functions. The alternating magnetic field was 15μT on the CT scanning line, which was also lower than the level influencing pacemaker functions. Malfunctions of the pacemaker during CT may be caused by diagnostic radiant rays and although they are transient, the possibility of lethal arrhythmia cannot be ignored. (author)

  19. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    Energy Technology Data Exchange (ETDEWEB)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A. [The University of Iowa, Department of Biomedical Engineering, Center for Computer Aided Design, Iowa City, IA (United States); Shivanna, Kiran H. [The University of Iowa, Center for Computer Aided Design, Iowa City, IA (United States); Magnotta, Vincent A. [The University of Iowa, Department of Biomedical Engineering, Department of Radiology, Center for Computer Aided Design, Iowa City, IA (United States); Grosland, Nicole M. [The University of Iowa, Department of Biomedical Engineering, Department of Orthopaedics and Rehabilitation, Center for Computer Aided Design, Iowa City, IA (United States)

    2008-01-15

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  20. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    International Nuclear Information System (INIS)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A.; Shivanna, Kiran H.; Magnotta, Vincent A.; Grosland, Nicole M.

    2008-01-01

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  1. Body composition measurement using computed tomography: Does the phase of the scan matter?

    Science.gov (United States)

    Rollins, Katie E; Javanmard-Emamghissi, Hannah; Awwad, Amir; Macdonald, Ian A; Fearon, Kenneth C H; Lobo, Dileep N

    2017-09-01

    The aim of this study was to determine, from the methodologic standpoint, the effect of the presence or absence of intravenous contrast on body composition variables obtained by analysis of computed tomography (CT) images. Triphasic abdominal (noncontrast, arterial phase, and portovenous phase contrast) CT scans from 111 patients were analyzed by two independent assessors at the third lumbar vertebral level using SliceOmatic software (version 5.0, TomoVision, Montreal, Canada). Variables included skeletal muscle index (SMI), fat and fat-free mass (FM and FFM, respectively), and mean skeletal muscle Hounsfield units (SMHU). Mean SMHU was lowest in the noncontrast phase (29.4, standard deviation [SD] 8.9 HU), followed by arterial (32.4, SD 9.3 HU) then portovenous phases (34.9, SD 9.4 HU). The mean skeletal muscle attenuation was significantly different depending on the phase of the scan in which the images were obtained. Calculated FM was significantly lower in both arterial (28.6, SD 8.8 kg, P definition of myosteatosis should include a standardized phase of CT for analysis and this should be incorporated within its definition. However, as the magnitudes of the differences were relatively small, the effect of the phase of the scan on predicting outcome needs to be determined. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Automated Quantification of Stroke Damage on Brain Computed Tomography Scans: e-ASPECTS

    Directory of Open Access Journals (Sweden)

    James Hampton-Till

    2015-08-01

    Full Text Available Emergency radiological diagnosis of acute ischaemic stroke requires the accurate detection and appropriate interpretation of relevant imaging findings. Non-contrast computed tomography (CT provides fast and low-cost assessment of the early signs of ischaemia and is the most widely used diagnostic modality for acute stroke. The Alberta Stroke Program Early CT Score (ASPECTS is a quantitative and clinically validated method to measure the extent of ischaemic signs on brain CT scans. The CE-marked electronic-ASPECTS (e-ASPECTS software automates the ASPECTS score. Anglia Ruskin Clinical Trials Unit (ARCTU independently carried out a clinical investigation of the e-ASPECTS software, an automated scoring system which can be integrated into the diagnostic pathway of an acute ischaemic stroke patient, thereby assisting the physician with expert interpretation of the brain CT scan. Here we describe a literature review of the clinical importance of reliable assessment of early ischaemic signs on plain CT scans, and of technologies automating these processed scoring systems in ischaemic stroke on CT scans focusing on the e-ASPECTS software. To be suitable for critical appraisal in this evaluation, the published studies needed a sample size of a minimum of 10 cases. All randomised studies were screened and data deemed relevant to demonstration of performance of ASPECTS were appraised. The literature review focused on three domains: i interpretation of brain CT scans of stroke patients, ii the application of the ASPECTS score in ischaemic stroke, and iii automation of brain CT analysis. Finally, the appraised references are discussed in the context of the clinical impact of e-ASPECTS and the expected performance, which will be independently evaluated by a non-inferiority study conducted by the ARCTU.

  3. Whole-heart 320-row computed tomography. Reduction of radiation dose via prior coronary calcium scanning

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, E.; Dewey, M. [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-01-15

    Purpose: The whole heart can be scanned in one rotation using 320-row coronary computed tomography angiography (CCTA), which covers up to 16 cm. Since most hearts are smaller, the total radiation dose may be reduced by adjusting the CCTA range to the individual heart size defined on a low-dose calcium scan (CACS). Materials and Methods: Forty-five patients with suspected coronary artery disease (13 women, 32 men; mean 61 {+-} 10 years) underwent CCTA preceded by low-dose CACS on a 320-row scanner (Aquilion ONE, Toshiba; 0.35 s gantry rotation, 120 kV, 350 - 450 mA) with 16-cm z-axis coverage (120 kV, 150 mA). The subsequent CCTA was performed over an adjusted scan range calculated as the individual heart size on CACS ({+-} 1 cm above and below). The total radiation dose of 16-cm CACS and the individually adjusted CCTA was compared with that of a calculated single CCTA using full 16-cm z-axis coverage. Results: CCTA could be performed with a reduced scan length in the z-axis in all patients. None of the scans had to be performed over the whole range of 16 cm. The adjusted scan length was 14 cm in 2 patients, 12.8 cm in 3 patients, and 12 cm in 40 patients. The effective CCTA scan range was 12.1 {+-} 0.5 cm based on mean individual heart sizes of 9.6 {+-} 1.1 cm. The mean total effective radiation dose of the entire cardiac CT examination (individually adapted CCTA and CACS) was significantly smaller than the exposure calculated for 16-cm CCTA without CACS (8.5 {+-} 4.7 vs. 9.1 {+-} 6.0 mSv, p = 0.006). The dose reduction was most relevant in patients with heart rates above 65 beats/min (n = 10) in whom 2 or 3 heartbeats were necessary for CCTA (17.7 {+-} 6.5 vs. 21.1 {+-} 8.4 mSv, p = 0.001). Conclusion: 320-row CCTA with an individually adjusted scan range based on prior CACS significantly reduces the radiation exposure compared with full 16-cm CCTA. (orig.)

  4. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    Directory of Open Access Journals (Sweden)

    Akinobu Watanabe

    Full Text Available Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT imaging. Complementary examination of external and internal osteology reveals (1 highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2 anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3 apneumatic sacral vertebrae; and (4 a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  5. Examination of Scanning Electron Microscope and Computed Tomography Images of PICA

    Science.gov (United States)

    Lawson, John W.; Stackpoole, Margaret M.; Shklover, Valery

    2010-01-01

    Micrographs of PICA (Phenolic Impregnated Carbon Ablator) taken using a Scanning Electron Microscope (SEM) and 3D images taken with a Computed Tomography (CT) system are examined. PICA is a carbon fiber based composite (Fiberform ) with a phenolic polymer matrix. The micrographs are taken at different surface depths and at different magnifications in a sample after arc jet testing and show different levels of oxidative removal of the charred matrix (Figs 1 though 13). CT scans, courtesy of Xradia, Inc. of Concord CA, were captured for samples of virgin PICA, charred PICA and raw Fiberform (Fig. 14). We use these images to calculate the thermal conductivity (TC) of these materials using correlation function (CF) methods. CF methods give a mathematical description of how one material is embedded in another and is thus ideally suited for modeling composites like PICA. We will evaluate how the TC of the materials changes as a function of surface depth. This work is in collaboration with ETH-Zurich, which has expertise in high temperature materials and TC modeling (including CF methods).

  6. Relative value of computed tomography scanning and venous sampling in establishing the cause of primary hyperaldosteronism

    International Nuclear Information System (INIS)

    Sheaves, R.; Goldin, J.; Reznek, R.H.

    1996-01-01

    The purpose of this study was to evaluate the relative merits of the postural simulation test, adrenal computed tomography (CT) and venous sampling in the differential diagnosis of patients presenting with primary hyperaldosteronism. The records of 20 patients presenting with primary hyperaldosteronism were reviewed retrospectively. There were 15 patients with a unilateral aldosterone-producing adenoma (APA), 4 patients with idiopathic hyperaldosteronism (IHA) and 1 patient with primary adrenal hyperplasia (PAH). Bilateral venous sampling of adrenal veins was attempted in all patients and blood collected for aldosterone and cortisol assay. Plasma aldosterone concentration increased after 4 h of standing in all cases of hyperplasia, but was also demonstrated in 10/15 patients with a surgically-proven APA. CT scanning correctly identified all 15 cases of APA and also classified correctly the remaining 5 cases of hyperplasia. CT scanning may be used alone to confirm the cause of hyperaldosteronism where postural studies suggest an adrenal adenoma, and such patients may be considered for early surgery. 21 refs

  7. Accuracy and reliability of a novel method for fusion of digital dental casts and cone beam computed tomography scans

    NARCIS (Netherlands)

    Rangel, F.A.; Maal, T.J.J.; Bronkhorst, E.M.; Breuning, K.H.; Schols, J.G.J.H.; Berge, S.J.; Kuijpers-Jagtman, A.M.

    2013-01-01

    Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental

  8. The Prevalence of Unanticipated Hamate Hook Abnormalities in Computed Tomography Scans: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Silke A. Spit

    2017-05-01

    Full Text Available Background:It is possible that some hamate hook fractures are not diagnosed or treated, thereby affecting the study of their natural history. Study of the prevalence of incidental hamate hook fractures, nonunions, and other abnormalities on computed tomography (CT ordered for another reason could document a subset of undiagnosed and untreated hamate hook fractures which might change our understanding about the natural history.Methods: Reports of 2489 hand, wrist, and forearm CT scans for hamate hook abnormalities were searched. We excluded 19 patients with anticipated hamate fractures and 1 patient that had a hamate hook excision. Twenty-eight patients had an unanticipated hamate hook abnormality.Results: There was a significant difference in the prevalence of incidental hamate hook abnormalities by sex but not by age. Among the 28 unexpected hamate hook abnormalities, there were 16 fractures of the base (12 acute, 1 nonunion, and 3 of uncertain age, 5 acute oblique fractures, and 7 tip abnormalities/ossicles. The patient with an incidental nonunion had a CT scan for wrist pain and was diagnosed with gout.All fractures involved a direct blow to the hand (distal radius or scaphoid fracture, or crush injury. The 7 patients with a hamate tip abnormality had a CT scan for a distal radius or metacarpal fracture, crush injury or wrist pain. Five acute fractures were treated operatively with excision and the other 23 fractures were treated nonoperatively.Conclusion: Hamate fractures can be diagnosed incidental to other hand and wrist problems on CT.

  9. Role of computed tomography (CT scan in staging of cervical carcinoma

    Directory of Open Access Journals (Sweden)

    T V Prasad

    2014-01-01

    Full Text Available Background & objectives: Staging of cervical carcinoma is done clinically using International Federation of Obstetrics and Gynecology (FIGO guidelines. It is based on physical examination findings and also includes results of biopsy, endoscopy and conventional radiological tests like chest radiograph, intravenous urography and barium enema. These conventional radiological investigations have largely been replaced by computed tomography (CT and magnetic resonance imaging (MRI at present. FIGO staging system does not consider CT and MRI mandatory; however, use of these modalities are encouraged. This prospective study was conducted to determine the role of CT in staging work up in women diagnosed with cervical carcinoma. Methods: Fifty three women diagnosed with cervical carcinoma were evaluated with contrast enhanced CT scan of abdomen and pelvis. CT scan images were especially evaluated to determine tumour size, invasion of parmetrium, pelvic walls, rectum, urinary bladder and ureters, pelvic or retroperitoneal lymphadenopathy and distant metastases. CT findings were associated with clinical findings and staging, including findings from cystoscopy and sigmoidoscopy. Results: There was a poor agreement between clinical and CT staging of cervical carcinoma. Primary tumour was demonstrated on CT in 36 (70% of 53 patients. CT underestimated the parametrial, vaginal and pelvic wall invasion when compared with physical examination. CT overestimated the urinary bladder and rectal invasion when compared with cysto-sigmoidoscopy, however, CT had 100 per cent negative predictive value (NPV to exclude bladder and rectal involvement. CT detection of lymph node enlargement and lung metastases influenced the management. Interpretation & conclusions: Our findings show that CT scan does not reliably correlate with clinical FIGO staging of cervical cancer. However, it can detect urinary obstruction as well as nodal or distant metastases and thus improves the

  10. Birt-Hogg-Dube syndrome prospectively detected by review of chest computed tomography scans.

    Directory of Open Access Journals (Sweden)

    Hye Jung Park

    Full Text Available Birt-Hogg-Dube syndrome (BHD is a rare disorder caused by mutations in the gene that encodes folliculin (FLCN and is inherited in an autosomal dominant manner. BHD is commonly accompanied by fibrofolliculomas, renal tumors, multiple pulmonary cysts, and spontaneous pneumothorax. The aim of this study was to detect BHD prospectively in patients undergoing chest computed tomography (CT scans and to evaluate further the characteristics of BHD in Korea.We prospectively checked and reviewed the chest CT scans obtained for 10,883 patients at Gangnam Severance Hospital, Seoul, Korea, from June 1, 2015 to May 31, 2016. Seventeen patients met the study inclusion criteria and underwent screening for FLCN mutation to confirm BHD. We analyzed the characteristics of the patients confirmed to have BHD and those for a further 6 patients who had previously been described in Korea.Six (0.06% of the 10,883 patients reviewed were diagnosed with BHD. There was no difference in demographic or clinical features between the patients with BHD (n = 6 and those without BHD (n = 11. Pneumothorax was present in 50% of the patients with BHD but typical skin and renal lesions were absent. The maximum size of the cysts in the BHD group (median 39.4 mm; interquartile range [IQR] 11.4 mm was significantly larger than that in the non-BHD group (median 15.8 mm; IQR 7.8 mm; P = 0.001. Variable morphology was seen in 100.0% of the cysts in the BHD group but in only 18.2% of the cysts in the non-BHD group (P = 0.002. Nine (95% of the total of 12 Korean patients with BHD had experienced pneumothorax. Typical skin and renal lesions were present in 20.0% of patients with BHD.Our findings suggest that BHD can be detected if chest CT scans are read in detail.

  11. Newly defined landmarks for a three-dimensionally based cephalometric analysis: a retrospective cone-beam computed tomography scan review.

    Science.gov (United States)

    Lee, Moonyoung; Kanavakis, Georgios; Miner, R Matthew

    2015-01-01

    To identify two novel three-dimensional (3D) cephalometric landmarks and create a novel three-dimensionally based anteroposterior skeletal measurement that can be compared with traditional two-dimensional (2D) cephalometric measurements in patients with Class I and Class II skeletal patterns. Full head cone-beam computed tomography (CBCT) scans of 100 patients with all first molars in occlusion were obtained from a private practice. InvivoDental 3D (version 5.1.6, Anatomage, San Jose, Calif) was used to analyze the CBCT scans in the sagittal and axial planes to create new landmarks and a linear 3D analysis (M measurement) based on maxillary and mandibular centroids. Independent samples t-test was used to compare the mean M measurement to traditional 2D cephalometric measurements, ANB and APDI. Interexaminer and intraexaminer reliability were evaluated using 2D and 3D scatterplots. The M measurement, ANB, and APDI could statistically differentiate between patients with Class I and Class II skeletal patterns (P < .001). The M measurement exhibited a correlation coefficient (r) of -0.79 and 0.88 with APDI and ANB, respectively. The overall centroid landmarks and the M measurement combine 2D and 3D methods of imaging; the measurement itself can distinguish between patients with Class I and Class II skeletal patterns and can serve as a potential substitute for ANB and APDI. The new three-dimensionally based landmarks and measurements are reliable, and there is great potential for future use of 3D analyses for diagnosis and research.

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  14. Design and application of Mark IV scanning system for radionuclide computed tomography of the brain

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Hoffman, E.J.; Phelps, M.E.; Ricci, A.; Reivich, M.

    1977-01-01

    The MARK IV system was built in our laboratory to provide fast and accurate radionuclide computed tomography (RCT). It is designed primarily for detecting commonly available radioactive labels such as 99 Tcsup(m), but it is also adapted to detecting positron emitters such as 18 F. The system has interlaced convergent collimation in a four-sided arrangement of 32 independent detectors which continuously rotate as a unit, detecting, processing and displaying the reconstructed data while the study progresses. During the scanning procedure, accumulated data are transferred to a digital computer for reconstruction processing. Data are corrected to equalize detector response and compensate for photon attenuation in the head. This program requires 30 seconds for completion, whereupon the final reconstruction, a 64 x 64 matrix from the single revolution, outputs to a core store and is displayed on the screen of a cathode-ray tube. As the rotation sequence continues, new data from each revolution are added to previous data and reprocessed for a new picture. Since the instrument operates at 50 s per revolution, the continuous collection and processing of data causes a new picture to appear on the display every 50 s as the study progresses. The operator may extend or curtail the duration of the examination according to the appearance of the picture. In practice, a five revolution (4.2 min.) scan is commonly used in most clinical studies. The instrument is a high sensitivity device with approximately uniform resolution (1.7 cm FWHM) throughout the section plane. Quantification of concentration of radioactivity in small regions is accurate and reproducible. The instrument has been applied to the study of alterations in cerebral vascular permeability, blood flow and blood volume, and to the study of cerebral glucose metabolism and cerebral spinal fluid distribution. (author)

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  16. Patterns of brown fat uptake of 18F-fluorodeoxyglucose in positron emission tomography/computed tomography scan

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    Fluorodeoxyglucose (FDG) positron emission tomography (PET) has become the common imaging modality in oncological practice. FDG uptake is seen in brown adipose tissue in a significant number of patients. Recognizing the uptake patterns is important for optimal FDG PET interpretation. The introduction of PET/computed tomography (PET/CT) revolutionized PET imaging, bringing much-needed anatomical information. Careful review and correlation of FDG PET images with anatomical imaging should be performed to characterize accurately any lesion having high FDG uptake

  17. Physics properties of non-helical scan using 320-row multi detector computed tomography

    International Nuclear Information System (INIS)

    Urikura, Atsushi; Nakaya, Yoshihiro; Kawatani, Keisuke; Kawashima, Ippei; Goto, Hironori; Ichikawa, Katsuhiro

    2012-01-01

    Recently, clinical applications utilizing 320-row multi detector computed tomography (320MDCT) have increased, and the physical image properties of 320MDCT have been more concerned. We evaluated the spatial resolution in scan plane and z-direction, image noise and low-contrast sensitivity of non-helical mode (320NH), 640 slices mode by a double slice reconstruction technology (640DS), and 64-row helical mode (64HE) by using a 320MDCT. The spatial resolution in z-direction was evaluated by the section sensitivity profile (SSP) measurement with the micro coin phantom and the contrast transfer ratio (CTR) with the 0.5-mm comb phantom. The in-plane spatial resolution of 320NH was uniform over all the slice positions. The spatial resolution in z-direction decreased from the cathode side toward the anode side. The image noise of the anode side was higher than that of the cathode side. The contrast to noise ratio as index of the low contrast sensitivity was uniform over all the slice position. The CTR of 320NH fluctuated in the z-position, and the fluctuation was improved by 640DS except for the center of rotation. (author)

  18. INTERNAL STRUCTURE OF A VERMICULAR IRONSTONE AS DETERMINED BY X-RAY COMPUTED TOMOGRAPHY SCANNING

    Directory of Open Access Journals (Sweden)

    Yuri Lopes Zinn

    2015-04-01

    Full Text Available Ironstones or petroplinthites are common materials in soils under humid tropical climate, generally defined as the result of Fe oxide accumulation in areas where the water table oscillates, and may exhibit considerable morphological variability. The aim of this study was to examine the internal structure and porosity of an ironstone fragment from a Petroferric Acrudox in Minas Gerais, Brazil, by computed tomography (CT and conventional techniques. The sample analyzed had total porosity of 59.5 %, with large macropores in the form of tubular channels and irregular vughs, the latter with variable degrees of infilling by material released from the ironstone walls or the soil matrix. The CT scan also showed that the ironstone has wide variation in the density of the solid phase, most likely due to higher concentrations or thick intergrowths of hematite and magnetite/maghemite, especially in its outer rims. The implications of these results for water retention and soil formation in ironstone environments are briefly discussed.

  19. Clinical study on eating disorders. Brain atrophy revealed by cranial computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Nishiwaki, Shinichi

    1988-06-01

    Cranial computed tomography (CT) scans were reviewed in 34 patients with anorexia nervosa (Group I) and 22 with bulimia (Group II) to elucidate the cause and pathological significance of morphological brain alterations. The findings were compared with those from 47 normal women. The incidence of brain atrophy was significantly higher in Group I (17/34, 50%) and Group II (11/22, 50%) than the control group (3/47, 6%). In Group I, there was a significant increase in the left septum-caudate distance, the maximum width of interhemispheric fissure, the width of the both-side Sylvian fissures adjacent to the skull, and the maximum width of the third ventricle. A significant increase in the maximum width of interhemispheric fissure and the width of the left-side Sylvian fissure adjacent to the skull were noted as well in Group II. Ventricular brain ratios were significantly higher in Groups I and II than the control group (6.76 and 7.29 vs 4.55). Brain atrophy did not correlate with age, body weight, malnutrition, eating behavior, depression, thyroid function, EEG findings, or intelligence scale. In Group I, serum cortisol levels after the administration of dexamethasone were correlated with ventricular brain ratio. (Namekawa, K) 51 refs.

  20. Dosimetry of cone beam computed tomography scanning for diagnosis and planning in implant dentistry

    International Nuclear Information System (INIS)

    Santos Pinto de A, E. L.; Manzi, F. R.; Goncalves Z, E.; Nogueira, M. S.; Fernandes Z, M. A.

    2015-10-01

    Full text: The radiation dose and estimate the radiation induced risk of cancer and morpho functional alterations according to BEIR VII (2006) and recommendations of the ICRP 103 (2007) were measured in cone beam computed tomography (CBCT) scanning (Tc Kodak 9000C 3D) in different oral and maxillofacial regions for diagnosis and planning in implant dentistry for each examination protocol: jaw full, maxilla full and jaw and maxilla full associated. Thermoluminescent dosimeters (TLD- 100 H) were placed in an Alderson-Rando in regions corresponding to the crystalline, parotid, submandibular and thyroid glands and ovaries. The highest values for entrance skin dose were observed in the region of the parotid and submandibular glands, 9.612 mGy to 7.912 mGy and 8.818 mGy to 0.483 mGy, respectively. All examination protocols presented on the right and left sides in the region of the submandibular gland the highest values for absorbed dose (D). In the jaw full exam the thyroid glands on both sides presented highest dose values than maxilla full exam. This study allowed measuring the entrance skin dose and the absorbed dose (D) highlighting a dosimetric preponderance to the salivary glands. With danger of to radiation that induces cancer risk was observed that the age group most likely to have to risk of cancer was 20 years, compared to 30, 40, 50, 60,70 and 80 years. (Author)

  1. Portable head computed tomography scanner--technology and applications: experience with 3421 scans.

    Science.gov (United States)

    Carlson, Andrew P; Yonas, Howard

    2012-10-01

    The use of head computed tomography (CT) is standard in the management of acute brain injury; however, there are inherent risks of transport of critically ill patients. Portable CT can be brought to the patient at any location. We describe the clinical use of a portable head CT scanner (CereTom: NeuroLogica: Danvers, MA) that can be brought to the patient's bedside or to other locations such as the operating room or angiography suite. Between June of 2006 and December of 2009, a total of 3421 portable CTs were performed. A total of 3278 (95.8%) were performed in the neuroscience intensive care unit (ICU) for an average of 2.6 neuroscience ICU CT scans per day. Other locations where CTs were performed included other ICUs (n = 97), the operating room (n = 53), the emergency department (n = 1), and the angiography suite (n = 2). Most studies were non-contrasted head CT, though other modalities including xenon/CT, contrasted CT, and CT angiography were performed. Portable head CT can reliably and consistently be performed at the patient's bedside. This should lead to decreased transportation-related morbidity and improved rapid decision making in the ICU, OR, and other locations. Further studies to confirm this clinical advantage are needed. Copyright © 2011 by the American Society of Neuroimaging.

  2. External cervical resorption: an analysis using cone beam and microfocus computed tomography and scanning electron microscopy.

    Science.gov (United States)

    Gunst, V; Mavridou, A; Huybrechts, B; Van Gorp, G; Bergmans, L; Lambrechts, P

    2013-09-01

    To provide a three-dimensional representation of external cervical resorption (ECR) with microscopy, stereo microscopy, cone beam computed tomography (CT), microfocus CT and scanning electron microscopy (SEM). External cervical resorption is an aggressive form of root resorption, leading to a loss of dental hard tissues. This is due to clastic action, activated by a damage of the covering cementum and stimulated probably by infection. Clinically, it is a challenging situation as it is characterized by a late symptomatology. This is due to the pericanalar protection from a resorption-resistant sheet, composed of pre-dentine and surrounding dentine. The clastic activity is often associated with an attempt to repair, seen by the formation of osteoid tissue. Cone beam CT is extremely useful in the diagnoses and treatment planning of ECR. SEM analyses provide a better insight into the activity of osteoclasts. The root canal is surrounded by a layer of dentine that is resistant to resorption. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  3. Dosimetry of cone beam computed tomography scanning for diagnosis and planning in implant dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Santos Pinto de A, E. L.; Manzi, F. R.; Goncalves Z, E. [Pontifical Catholic University of Minas Gerais, Av. Jose Gaspar 500, 30535-901 Belo Horizonte, Minas Gerais (Brazil); Nogueira, M. S.; Fernandes Z, M. A., E-mail: madelon@cdtn.br [Development Center of Nuclear Technology / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Full text: The radiation dose and estimate the radiation induced risk of cancer and morpho functional alterations according to BEIR VII (2006) and recommendations of the ICRP 103 (2007) were measured in cone beam computed tomography (CBCT) scanning (Tc Kodak 9000C 3D) in different oral and maxillofacial regions for diagnosis and planning in implant dentistry for each examination protocol: jaw full, maxilla full and jaw and maxilla full associated. Thermoluminescent dosimeters (TLD- 100 H) were placed in an Alderson-Rando in regions corresponding to the crystalline, parotid, submandibular and thyroid glands and ovaries. The highest values for entrance skin dose were observed in the region of the parotid and submandibular glands, 9.612 mGy to 7.912 mGy and 8.818 mGy to 0.483 mGy, respectively. All examination protocols presented on the right and left sides in the region of the submandibular gland the highest values for absorbed dose (D). In the jaw full exam the thyroid glands on both sides presented highest dose values than maxilla full exam. This study allowed measuring the entrance skin dose and the absorbed dose (D) highlighting a dosimetric preponderance to the salivary glands. With danger of to radiation that induces cancer risk was observed that the age group most likely to have to risk of cancer was 20 years, compared to 30, 40, 50, 60,70 and 80 years. (Author)

  4. Motion estimation for cardiac functional analysis using two x-ray computed tomography scans.

    Science.gov (United States)

    Fung, George S K; Ciuffo, Luisa; Ashikaga, Hiroshi; Taguchi, Katsuyuki

    2017-09-01

    This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise then degrades the accuracy of motion estimation. Moreover, even if the scan was performed during the sinus rhythm, the cardiac motion observed in CT images may not be cyclic with patients with atrial fibrillation. In this study, we propose to use two CT scan data, one for CT angiography at a quiescent phase at a standard dose and the other for CFA over the entire heart beat at a lower dose. We have made the following four modifications to an image-based cardiac motion estimation method we have previously developed for a full-dose retrospectively gated coronary CT angiography: (a) a full-dose prospectively gated coronary CT angiography image acquired at the least motion phase was used as the reference image; (b) a three-dimensional median filter was applied to lower-dose retrospectively gated cardiac images acquired at 20 phases over one heartbeat in order to reduce image noise; (c) the strength of the temporal regularization term was made adaptive; and (d) a one-dimensional temporal filter was applied to the estimated motion vector field in order to decrease jaggy motion patterns. We describe the conventional method iME1 and the proposed method iME2 in this article. Five observers assessed the accuracy of the estimated motion vector field of iME2 and iME1 using a 4-point scale. The observers repeated the assessment with data presented in a new random order 1 week after the first assessment session. The study confirmed that the proposed iME2 was robust against the mismatch of noise levels, contrast enhancement levels, and shapes of the chambers. There was a statistically significant difference between iME2 and iME1 (accuracy score, 2.08 ± 0.81 versus 2.77

  5. Dosimetric study in chest computed tomography scans of adult and pediatric phantoms

    International Nuclear Information System (INIS)

    Namen A, W.; Prata M, A.; Guedes, G.

    2016-10-01

    The computed tomography scan is a radiological technique that permits an evaluation of the patient internal structures. In the last ten years, this technique has had a high growth due to clinical cases of medical emergencies, cancer and pediatric trauma. Widespread of this technique has a significant increase in the patient dose. The risk associated with the radiological examination can be considered very low compared to the natural risk. However, any additional risk, no matter how small, is unacceptable if it does not benefit the patient. To be aware of the dose distribution is important when the objective is to vary the acquisition parameters aiming a dose reduction. The aim os this study is develop a pediatric chest phantom to evaluate the dose variation in CT scans. In this work, a cylindrical adult chest phantom made in polymethyl methacrylate was used and a second chest phantom was developed, based on dimensions of in eight year old patient in oblong shape. The two simulators have 5 openings, one is central and four are peripheral lagged by 90 degrees Celsius, which allow positioning a pencil chamber aiming and observation of the dose in 5 regions. In a GE CT scanner, Discovery model and 64 channels, the central slice of both simulators were irradiated successively to obtain dose measurements using a pencil chamber. The irradiation of the central slice was conducted using the service protocol. The registered dose values showed that the pediatric phantom had higher doses especially in the anterior, posterior and central regions. The results also enabled a comparison among the index dose values obtained from the measurements with the pencil chamber. (Author)

  6. Dosimetric study in chest computed tomography scans of adult and pediatric phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Namen A, W.; Prata M, A. [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Guedes, G., E-mail: wadia.namen@gmail.com [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    The computed tomography scan is a radiological technique that permits an evaluation of the patient internal structures. In the last ten years, this technique has had a high growth due to clinical cases of medical emergencies, cancer and pediatric trauma. Widespread of this technique has a significant increase in the patient dose. The risk associated with the radiological examination can be considered very low compared to the natural risk. However, any additional risk, no matter how small, is unacceptable if it does not benefit the patient. To be aware of the dose distribution is important when the objective is to vary the acquisition parameters aiming a dose reduction. The aim os this study is develop a pediatric chest phantom to evaluate the dose variation in CT scans. In this work, a cylindrical adult chest phantom made in polymethyl methacrylate was used and a second chest phantom was developed, based on dimensions of in eight year old patient in oblong shape. The two simulators have 5 openings, one is central and four are peripheral lagged by 90 degrees Celsius, which allow positioning a pencil chamber aiming and observation of the dose in 5 regions. In a GE CT scanner, Discovery model and 64 channels, the central slice of both simulators were irradiated successively to obtain dose measurements using a pencil chamber. The irradiation of the central slice was conducted using the service protocol. The registered dose values showed that the pediatric phantom had higher doses especially in the anterior, posterior and central regions. The results also enabled a comparison among the index dose values obtained from the measurements with the pencil chamber. (Author)

  7. Refinement of clinical X-ray computed tomography (CT) scans containing metal implants.

    Science.gov (United States)

    Treece, Graham

    2017-03-01

    X-ray computed tomography (CT) data contains artefacts from many sources, with sufficient prominence to affect diagnostic utility when metal is present in the scans. These artefacts can be reduced, usually by the removal and in-filling of any sinogram data which has been affected by metal, and several such techniques have been proposed. Most of them are prone to introducing new artefacts into the CT data or may take a long time to correct the data. It is the purpose of this paper to introduce a new technique which is fast, yet can effectively remove most artefacts without introducing significant new ones. The new metal artefact reduction technique (RMAR) consists of an iterative refinement of the CT data by alternately forward- and back-projecting the part of the reconstruction near to metal. The forward-projection is corrected by making use of a prior derived from the reconstructed data which is independently estimated for each projection angle, and smoothed using a newly developed Bitonic filter. The new technique is compared with previously published (LI, NMAR, MDT) and commercial (O-MAR, IMAR) alternatives, quantitatively on phantom data, and qualitatively on a selection of clinical scans, mostly of the hip. The phantom data is from two recently published studies, enabling direct comparison with previous results. The results show an increased reduction of artefacts on the four phantom data sets tested. On two of the phantom data sets, RMAR is significantly better (pCT data, RMAR can correct each image in 3-8s, which is more than one hundred times faster than MDT. The new technique is demonstrated to have performance at least as good as MDT, with both out-performing other approaches. However, it is much faster then the latter technique, and shows better preservation of data very close to metal. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Computed tomography automatic exposure control techniques in 18F-FDG oncology PET-CT scanning.

    Science.gov (United States)

    Iball, Gareth R; Tout, Deborah

    2014-04-01

    Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging. An audit of 70 patients was performed for half-body CT scans taken on a GE Discovery 690, Philips Gemini TF and Siemens Biograph mCT (all 64-slice CT). Patient demographic and dose information was recorded and image noise was calculated as the SD of Hounsfield units in the liver. A direct comparison of the AEC systems was made by scanning a Rando phantom on all three systems for a range of AEC settings. The variation in dose and image quality with patient weight was significantly different for all three systems, with the GE system showing the largest variation in dose with weight and Philips the least. Image noise varied with patient weight in Philips and Siemens systems but was constant for all weights in GE. The z-axis mA profiles from the Rando phantom demonstrate that these differences are caused by the nature of the tube current modulation techniques applied. The mA profiles varied considerably according to the AEC settings used. CT AEC techniques from the three manufacturers yield significantly different tube current modulation patterns and hence deliver different doses and levels of image quality across a range of patient weights. Users should be aware of how their system works and of steps that could be taken to optimize imaging protocols.

  9. Image reconstruction. Application to transverse axial tomography

    International Nuclear Information System (INIS)

    Aubry, Florent.

    1977-09-01

    A method of computerized tridimensional image reconstruction from their projection, especially in the computerized transverse axial tomography is suggested. First, the different techniques actually developped and presented in the literature are analyzed. Then, the equipment used is briefly described. The reconstruction algorithm developped is presented. This algorithm is based on the convolution method, well adapted to the real conditions of exploitation. It is an extension of SHEPP and LOGAN's algorithm. A correction of the self absorption and of the detector's response is proposed. Finally, the first results obtained which are satisfactory are given. The simplicity of the method which does not need a too long computation time makes possible the implementation of the algorithm on a mini-computer [fr

  10. Diagnostic value of axial CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal. (author)

  11. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

    Science.gov (United States)

    Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-03-01

    This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

  12. Computed Tomography Scanning and Geophysical Measurements of Core from the Coldstream 1MH Well

    Energy Technology Data Exchange (ETDEWEB)

    Crandall, Dustin M.; Brown, Sarah; Moore, Johnathan E.; Mackey, Paige E.; Paronish, Thomas J.

    2018-03-05

    The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Shale from a vertical well, the Coldstream 1MH Well in Clearfield County, PA. The core is comprised primarily of the Marcellus Shale from a depth of 7,002 to 7,176 ft.

    The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica shale formations. As part of this effort, bulk scans of core were obtained from the Coldstream 1MH well, provided by the Energy Corporation of America (now Greylock Energy). This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/coldstream-1mh-well.

    All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. En echelon fractures were observed at 7,100 ft and were CT scanned using NETL’s industrial CT scanner at higher resolution. The ability to quickly identify key areas for more detailed study with higher resolution will save time and

  13. Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans

    NARCIS (Netherlands)

    Al-Rawi, B.; Hassan, B.; Vandenberge, B.; Jacobs, R.

    2010-01-01

    The use of three-dimensional (3D) models of the dentition obtained from cone beam computed tomography (CBCT) is becoming increasingly more popular in dentistry. A recent trend is to replace the traditional dental casts with digital CBCT models for diagnosis, treatment planning and simulation. The

  14. Incidental findings on cone beam computed tomography scans in cleft lip and palate patients

    NARCIS (Netherlands)

    Kuijpers, Mette A. R.; Pazera, Andrzej; Admiraal, Ronald J.; Berge, Stefaan J.; Vissink, Arjan; Pazera, Pawel

    Cone beam computed tomography (CBCT) is frequently used in treatment planning for alveolar bone grafting (ABG) and orthognathic surgery in patients with cleft lip and palate (CLP). CBCT images may depict coincident findings. The aim of this study was to assess the prevalence of incidental findings

  15. Incidental findings on cone beam computed tomography scans in cleft lip and palate patients

    NARCIS (Netherlands)

    Kuijpers, M.A.R.; Pazera, A.; Admiraal, R.J.C.; Berge, S.J.; Vissink, A.; Pazera, P.

    2014-01-01

    OBJECTIVES: Cone beam computed tomography (CBCT) is frequently used in treatment planning for alveolar bone grafting (ABG) and orthognathic surgery in patients with cleft lip and palate (CLP). CBCT images may depict coincident findings. The aim of this study was to assess the prevalence of

  16. Cemento-Osseous Dysplasias: Imaging Features Based on Cone Beam Computed Tomography Scans.

    Science.gov (United States)

    Cavalcanti, Paulo Henrique Pereira; Nascimento, Eduarda Helena Leandro; Pontual, Maria Luiza Dos Anjos; Pontual, Andréa Dos Anjos; Marcelos, Priscylla Gonçalves Correia Leite de; Perez, Danyel Elias da Cruz; Ramos-Perez, Flávia Maria de Moraes

    2018-01-01

    Imaging exams have important role in diagnosis of cemento-osseous dysplasia (COD). Cone beam computed tomography (CBCT) stands out for allowing three-dimensional image evaluation. This study aimed to assess the prevalence of cases diagnosed as COD on CBCT scans, as well identify the main imaging features related to these lesions. An analysis was performed in a database containing 22,400 radiological reports, in which all cases showing some type of COD were initially selected. These CBCT exams were reevaluated to confirm the radiographic diagnosis and determine the prevalence and distribution of the types of COD with regard to gender, age and preferred location, while describing its most common imaging aspects. Data were presented using descriptive analyses. There were 82 cases diagnosed as COD in the CBCT images (prevalence of 0.4%). The distribution of patients was 11 (13.4%) male and 71 (86.6%) female, with a mean age of 49.8 years (age-range 17-85 years). There were 47 (57.3%) cases of periapical COD, 23 (28%) of focal COD and 12 (14.6%) of florid COD. The mandible was more affected than the maxilla. In most cases, the lesions were mixed or hyperdense. All COD had well-defined limits and there were no cases of tooth displacement. In conclusion, periapical COD was the most common type and the most affected bone was the mandible. Imaging evaluation is critical for diagnosis and dentists should bear in mind all possible radiographic presentations of COD in order to prevent misleading diagnoses and consequently, inadequate treatments.

  17. Accuracy and reliability of a novel method for fusion of digital dental casts and Cone Beam Computed Tomography scans.

    Directory of Open Access Journals (Sweden)

    Frits A Rangel

    Full Text Available Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods.

  18. Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans

    Science.gov (United States)

    Rangel, Frits A.; Maal, Thomas J. J.; Bronkhorst, Ewald M.; Breuning, K. Hero; Schols, Jan G. J. H.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2013-01-01

    Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods. PMID:23527111

  19. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    OpenAIRE

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions wer...

  20. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  2. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  3. Computer-aided detection system for lung cancer in computed tomography scans: Review and future prospects

    Science.gov (United States)

    2014-01-01

    Introduction The goal of this paper is to present a critical review of major Computer-Aided Detection systems (CADe) for lung cancer in order to identify challenges for future research. CADe systems must meet the following requirements: improve the performance of radiologists providing high sensitivity in the diagnosis, a low number of false positives (FP), have high processing speed, present high level of automation, low cost (of implementation, training, support and maintenance), the ability to detect different types and shapes of nodules, and software security assurance. Methods The relevant literature related to “CADe for lung cancer” was obtained from PubMed, IEEEXplore and Science Direct database. Articles published from 2009 to 2013, and some articles previously published, were used. A systemic analysis was made on these articles and the results were summarized. Discussion Based on literature search, it was observed that many if not all systems described in this survey have the potential to be important in clinical practice. However, no significant improvement was observed in sensitivity, number of false positives, level of automation and ability to detect different types and shapes of nodules in the studied period. Challenges were presented for future research. Conclusions Further research is needed to improve existing systems and propose new solutions. For this, we believe that collaborative efforts through the creation of open source software communities are necessary to develop a CADe system with all the requirements mentioned and with a short development cycle. In addition, future CADe systems should improve the level of automation, through integration with picture archiving and communication systems (PACS) and the electronic record of the patient, decrease the number of false positives, measure the evolution of tumors, evaluate the evolution of the oncological treatment, and its possible prognosis. PMID:24713067

  4. Unusual cause for recurrent Cushing syndrome and its diagnosis by computed tomography and NP-59 radiocholesterol scanning

    International Nuclear Information System (INIS)

    Harris, R.D.; Herwig, K.R.

    1990-01-01

    Cushing syndrome can recur following an adrenalectomy. One of the primary causes is recurrence of adrenal carcinoma either locally or from metastases. Hyperplasia and hyperfunction of adrenal remnants may also occur if there is pituitary stimulation. We have a patient in whom recurrent Cushing syndrome developed from small nonmalignant deposits of adrenal tissue in the perirenal adipose tissue following adrenalectomy of a benign adenoma. These deposits were identifiable by computed tomography. A false-negative NP-59 iodocholesterol scan was instructive in pointing out some problems in the interpretation of this type of scan for adrenal tissue

  5. Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans

    Energy Technology Data Exchange (ETDEWEB)

    Veldhoen, Simon [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); University Hospital Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Schoellchen, Maximilian; Hanken, H.; Precht, C.; Heiland, M. [University Medical Center Hamburg, Department of Oral- and Maxillofacial Surgery, Hamburg (Germany); Henes, F.O.; Adam, G.; Regier, M. [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schoen, G. [University Medical Center Hamburg, Department of Medical Biometry and Epidemiology, Hamburg (Germany); Nagel, H.D. [Science and Technology for Radiology, Buchholz (Germany); Schumacher, U. [University Medical Center Hamburg, Institute of Anatomy, Hamburg (Germany)

    2017-02-15

    To compare multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) regarding radiation, resolution, image noise, and image quality. CBCT and 256-MDCT were compared based on three scan protocols: Standard-dose (∼24 mGy), reduced-dose (∼9 mGy), and low-dose (∼4 mGy). MDCT images were acquired in standard- and high-resolution mode (HR-MDCT) and reconstructed using filtered back projection (FBP) and iterative reconstruction (IR). Spatial resolution in linepairs (lp) and objective image noise (OIN) were assessed using dedicated phantoms. Image quality was assessed in scans of 25 cadaver heads using a Likert scale. OIN was markedly higher in FBP-MDCT when compared to CBCT. IR lowered the OIN to comparable values in standard-mode MDCT only. CBCT provided a resolution of 13 lp/cm at standard-dose and 11 lp/cm at reduced-dose vs. 11 lp/cm and 10 lp/cm in HR-MDCT. Resolution of 10 lp/cm was observed for both devices using low-dose settings. Quality scores of MDCT and CBCT did not differ at standard-dose (CBCT, 3.4; MDCT, 3.3-3.5; p > 0.05). Using reduced- and low-dose protocols, CBCT was superior (reduced-dose, 3.2 vs. 2.8; low dose, 3.0 vs. 2.3; p < 0.001). Using the low-dose protocol, the assessed CBCT provided better objective and subjective image quality and equality in resolution. Similar image quality, but better resolution using CBCT was observed at higher exposure settings. (orig.)

  6. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  7. When the non-contrast-enhanced phase is unnecessary in abdominal computed tomography scans? A retrospective analysis of 244 cases

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Danilo Manuel Cerqueira; Salvadori, Priscila Silveira; Monjardim, Rodrigo da Fonseca; Bretas, Elisa Almeida Sathler; Torres, Lucas Rios; Caldana, Rogerio Pedreschi; Shigueoka, David Carlos; Medeiros, Regina Bitelli; D' ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2013-06-15

    Objective: to evaluate the necessity of the non contrast-enhanced phase in abdominal computed tomography scans. Materials and Methods: A retrospective, cross-sectional, observational study was developed, evaluating 244 consecutive abdominal computed tomography scans both with and without contrast injection. Initially, the contrast-enhanced images were analyzed (first analysis). Subsequently, the observers had access to the non-contrast-enhanced images for a second analysis. The primary and secondary diagnoses were established as a function of the clinical indications for each study (such as tumor staging, acute abdomen, investigation for abdominal collection and hepatocellular carcinoma, among others). Finally, the changes in the diagnoses resulting from the addition of the non-contrast-enhanced phase were evaluated. Results: Only one (0.4%; p > 0.999; non-statistically significant) out of the 244 reviewed cases had the diagnosis changed after the reading of non-contrast-enhanced images. As the secondary diagnoses are considered, 35 (14%) cases presented changes after the second analysis, as follows: nephrolithiasis (10%), steatosis (3%), adrenal nodule (0.7%) and cholelithiasis (0.3%). Conclusion: For the clinical indications of tumor staging, acute abdomen, investigation of abdominal collections and hepatocellular carcinoma, the non-contrast-enhanced phase can be excluded from abdominal computed tomography studies with no significant impact on the diagnosis. (author)

  8. Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography.

    Science.gov (United States)

    Ma, Chi; Yu, Lifeng; Chen, Baiyu; Favazza, Christopher; Leng, Shuai; McCollough, Cynthia

    2016-04-01

    Channelized Hotelling observer (CHO) models have been shown to correlate well with human observers for several phantom-based detection/classification tasks in clinical computed tomography (CT). A large number of repeated scans were used to achieve an accurate estimate of the model's template. The purpose of this study is to investigate how the experimental and CHO model parameters affect the minimum required number of repeated scans. A phantom containing 21 low-contrast objects was scanned on a 128-slice CT scanner at three dose levels. Each scan was repeated 100 times. For each experimental configuration, the low-contrast detectability, quantified as the area under receiver operating characteristic curve, [Formula: see text], was calculated using a previously validated CHO with randomly selected subsets of scans, ranging from 10 to 100. Using [Formula: see text] from the 100 scans as the reference, the accuracy from a smaller number of scans was determined. Our results demonstrated that the minimum number of repeated scans increased when the radiation dose level decreased, object size and contrast level decreased, and the number of channels increased. As a general trend, it increased as the low-contrast detectability decreased. This study provides a basis for the experimental design of task-based image quality assessment in clinical CT using CHO.

  9. Prospective evaluation of fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) for axillary staging in breast cancer

    International Nuclear Information System (INIS)

    Yamaguchi, Masahide; Noguchi, Akinori; Tani, Naoki

    2008-01-01

    Seventy-two patients from 2005 October to 2007 February with operative breast cancer underwent fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) of chest and body, ultrasound scan (US) and enhanced computed tomography scan (CT) followed by sentinel lymph node biopsy (SLNB) and axillary lymph node dissection (ALND). The results of PET/CT were compared with histopathological diagnosis of SLNB and ALND. Sensitivity, specificity and accuracy of PET/CT for detection of axillary lymph node metastases were 61%, 96% and 88%, respectively. Seven false-negative and two false-positive of PET/CT results were found. In patients with false-negative of PET/CT results there are two skin-invasive breast cancer patients and axillary lymph node metastases were detected in three patients with US, in one with CT and in four with SLNB. In clinical method for diagnosis of axillary lymph node metastases SLNB should be recommended because sensitivity of PET/CT for early breast cancer patients were low and positive diagnosis of axillary lymph node metastases with PET needs more than 1 cm size of lesion. PET/CT is useful for not-early breast cancer patients. To decide the operation of axillary lymph node disection needs total diagnosis of US, CT, SLNB and clinical findings. (author)

  10. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  11. Effect of variable scanning protocolson the pre-implant site evaluation of the mandible in reformatted computed tomography

    International Nuclear Information System (INIS)

    Kim, Kee Deog; Park, Chang Seo

    1999-01-01

    To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. On image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal and in horizontal measurement, there was no statistically significant difference among conventional and helical scans with pitches of 1.0, 1.5 and 2.0. In vertical measurement, there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of pre-dental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  12. Reversible bronchial dilatation in children: comparison of serial high-resolution computer tomography scans of the lungs

    Energy Technology Data Exchange (ETDEWEB)

    Gaillard, E.A. E-mail: erol.gaillard@lwh-tr.nwest.nhs.uk; Carty, H.; Heaf, D.; Smyth, R.L

    2003-09-01

    Introduction: bronchiectasis is generally considered irreversible in the adult population, largely based on studies employing bronchography in cases with a significant clinical history. It is assumed, that the same is true for children. Few studies have examined the natural history of bronchiectasis in children and diagnostic criteria on high-resolution computer tomography of the lungs are derived from studies on adults. Frequently, bronchiectasis is reported in children in cases where localised bronchial dilatation is present, incorrectly labelling these children with an irreversible life-long condition. Objective: to evaluate changes in appearance of bronchial dilatation, unrelated to cystic fibrosis in children, as assessed by sequential high-resolution computer tomography (HRCT) of the lungs. Methods: the scans of 22 children with a radiological diagnosis of bronchiectasis, seen at Alder Hey Children's Hospital between 1994 and 2000, who had at least two CT scans of the lungs were reviewed by a single radiologist, who was blinded to the original report. Results: following a median scan interval of 21 months (range 2-43), bronchial dilatation resolved completely in six children and there was improvement in appearances in a further eight, with medical treatment alone. Discussion: a radiological diagnosis of bronchiectasis should be considered with caution in children as diagnostic criteria derived from studies in adults have not been validated in children and the condition is generally considered irreversible.

  13. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

    Science.gov (United States)

    Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico

    2017-04-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  16. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  17. Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull.

    Science.gov (United States)

    Berco, Mauricio; Rigali, Paul H; Miner, R Matthew; DeLuca, Stephelynn; Anderson, Nina K; Will, Leslie A

    2009-07-01

    The purpose of this study was to determine the accuracy and reliability of 3-dimensional craniofacial measurements obtained from cone-beam computed tomography (CBCT) scans of a dry human skull. Seventeen landmarks were identified on the skull. CBCT scans were then obtained, with 2 skull orientations during scanning. Twenty-nine interlandmark linear measurements were made directly on the skull and compared with the same measurements made on the CBCT scans. All measurements were made by 2 operators on 4 separate occasions. The method errors were 0.19, 0.21, and 0.19 mm in the x-, y- and z-axes, respectively. Repeated measures analysis of variance (ANOVA) showed no significant intraoperator or interoperator differences. The mean measurement error was -0.01 mm (SD, 0.129 mm). Five measurement errors were found to be statistically significantly different; however, all measurement errors were below the known voxel size and clinically insignificant. No differences were found in the measurements from the 2 CBCT scan orientations of the skull. CBCT allows for clinically accurate and reliable 3-dimensional linear measurements of the craniofacial complex. Moreover, skull orientation during CBCT scanning does not affect the accuracy or the reliability of these measurements.

  18. Automated segmentation of pulmonary structures in thoracic computed tomography scans: a review

    International Nuclear Information System (INIS)

    Van Rikxoort, Eva M; Van Ginneken, Bram

    2013-01-01

    Computed tomography (CT) is the modality of choice for imaging the lungs in vivo. Sub-millimeter isotropic images of the lungs can be obtained within seconds, allowing the detection of small lesions and detailed analysis of disease processes. The high resolution of thoracic CT and the high prevalence of lung diseases require a high degree of automation in the analysis pipeline. The automated segmentation of pulmonary structures in thoracic CT has been an important research topic for over a decade now. This systematic review provides an overview of current literature. We discuss segmentation methods for the lungs, the pulmonary vasculature, the airways, including airway tree construction and airway wall segmentation, the fissures, the lobes and the pulmonary segments. For each topic, the current state of the art is summarized, and topics for future research are identified. (topical review)

  19. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...... patients. With the same SPECT the distribution of PAO was measured after intravenous injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6-10 mm (HR) and 15-20 mm (LR). PAO images showed close resemblance to 133Xe CBF tomograms. Only 20 per cent...... of the (decay corrected) brain counts were lost during 24 hours....

  20. Estudo de caso de oferta induzindo a demanda: o caso da oferta de exames de imagem (tomografia axial computadorizada e ressonância magnética na Unimed-Manaus Case study of supply induced demand: the case of provision of imaging scans (computed tomography and magnetic resonance at Unimed-Manaus

    Directory of Open Access Journals (Sweden)

    Edson de Oliveira Andrade

    2011-04-01

    Full Text Available OBJETIVO: Apresentar a experiência de uma operadora de plano de saúde (Unimed-Manaus na cidade de Manaus, Estado do Amazonas, com o credenciamento de serviços de imagem e a indução de demanda pela oferta dos novos serviços (Lei de Roemer. MÉTODOS: Trata-se de uma pesquisa de caráter retrospectivo, com estudo de série temporal, abordando o período de janeiro de 1998 a junho de 2004, lapso de tempo em que ocorreu a implantação dos serviços de tomografia computadorizada e da ressonância magnética no âmbito dos serviços oferecidos por aquele plano de saúde. A análise estatística consistiu em uma parte descritiva e uma inferencial, sendo esta última utilizando teste paramétrico de média (teste t de Student e ANOVA e o teste de correlação de Pearson. Foi adotado um alfa de 5% e um intervalo de confiança de 95%. RESULTADOS: Foi possível identificar na Unimed-Manaus que a oferta de novos serviços de imagem foi capaz de, por si só, gerar um aumento da demanda do serviço caracterizando o fenômeno descrito por Roemer. CONCLUSÃO: Os resultados deste trabalho ressaltam a necessidade de se estar atento ao fato de que a oferta de novos serviços no setor da saúde poderá acarretar, por si só, um aumento de sua utilização sem que haja uma demanda real.OBJECTIVE: To present the experience of a health plan operator (Unimed-Manaus in Manaus, Amazonas, Brazil, with the accreditation of imaging services and the demand induced by the supply of new services (Roemer's Law. METHODS: This is a retrospective work studying a time series covering the period from January 1998 to June 2004, in which the computed tomography and the magnetic resonance imaging services were implemented as part of the services offered by that health plan operator. Statistical analysis consisted of a descriptive and an inferential part, with the latter using a mean parametric test (Student T-test and ANOVA and the Pearson correlation test. A 5% alpha and a 95

  1. Automatic quantitative micro-computed tomography evaluation of angiogenesis in an axially vascularized tissue-engineered bone construct.

    Science.gov (United States)

    Arkudas, Andreas; Beier, Justus Patrick; Pryymachuk, Galyna; Hoereth, Tobias; Bleiziffer, Oliver; Polykandriotis, Elias; Hess, Andreas; Gulle, Heinz; Horch, Raymund E; Kneser, Ulrich

    2010-12-01

    We invented an automatic observer-independent quantitative method to analyze vascularization using micro-computed tomography (CT) along with three-dimensional (3D) reconstruction in a tissue engineering model. An arteriovenous loop was created in the medial thigh of 30 rats and was placed in a particulated porous hydroxyapatite and beta-tricalcium phosphate matrix, filled with fibrin (10 mg/mL fibrinogen and 2 IU/mL thrombin) without (group A) or with (group B) application of fibrin-gel-immobilized angiogenetic growth factors vascular endothelial growth factor (VEGF¹⁶⁵) and basic fibroblast growth factor (bFGF). The explantation intervals were 2, 4, and 8 weeks. Specimens were investigated by means of micro-CT followed by an automatic 3D analysis, which was correlated to histomorphometrical findings. In both groups, the arteriovenous loop led to generation of dense vascularized connective tissue with differentiated and functional vessels inside the matrix. Quantitative analysis of vascularization using micro-CT showed to be superior to histological analysis. The micro-CT analysis also allows the assessment of different other, more complex vascularization parameters within 3D constructs, demonstrating an early improvement of vascularization by application of fibrin-gel-immobilized VEGF¹⁶⁵ and bFGF. In this study quantitative analysis of vascularization using micro-CT along with 3D reconstruction and automatic analysis exhibit to be a powerful method superior to histological evaluation of cross sections.

  2. Computed tomography

    International Nuclear Information System (INIS)

    Boyd, D.P.

    1989-01-01

    This paper reports on computed tomographic (CT) scanning which has improved computer-assisted imaging modalities for radiologic diagnosis. The advantage of this modality is its ability to image thin cross-sectional planes of the body, thus uncovering density information in three dimensions without tissue superposition problems. Because this enables vastly superior imaging of soft tissues in the brain and body, CT scanning was immediately successful and continues to grow in importance as improvements are made in speed, resolution, and cost efficiency. CT scanners are used for general purposes, and the more advanced machines are generally preferred in large hospitals, where volume and variety of usage justifies the cost. For imaging in the abdomen, a scanner with a rapid speed is preferred because peristalsis, involuntary motion of the diaphram, and even cardiac motion are present and can significantly degrade image quality. When contrast media is used in imaging to demonstrate scanner, immediate review of images, and multiformat hardcopy production. A second console is reserved for the radiologist to read images and perform the several types of image analysis that are available. Since CT images contain quantitative information in terms of density values and contours of organs, quantitation of volumes, areas, and masses is possible. This is accomplished with region-of- interest methods, which involve the electronic outlining of the selected region of the television display monitor with a trackball-controlled cursor. In addition, various image- processing options, such as edge enhancement (for viewing fine details of edges) or smoothing filters (for enhancing the detectability of low-contrast lesions) are useful tools

  3. Early Chest Computed Tomography Scan to Assist Diagnosis and Guide Treatment Decision for Suspected Community-acquired Pneumonia.

    Science.gov (United States)

    Claessens, Yann-Erick; Debray, Marie-Pierre; Tubach, Florence; Brun, Anne-Laure; Rammaert, Blandine; Hausfater, Pierre; Naccache, Jean-Marc; Ray, Patrick; Choquet, Christophe; Carette, Marie-France; Mayaud, Charles; Leport, Catherine; Duval, Xavier

    2015-10-15

    Clinical decision making relative to community-acquired pneumonia (CAP) diagnosis is difficult. Chest radiograph is key in establishing parenchymal lung involvement. However, radiologic performance may lead to misdiagnosis, rendering questionable the use of chest computed tomography (CT) scan in patients with clinically suspected CAP. To assess whether early multidetector chest CT scan affects diagnosis and management of patients visiting the emergency department with suspected CAP. A total of 319 prospectively enrolled patients with clinically suspected CAP underwent multidetector chest CT scan within 4 hours. CAP diagnosis probability (definite, probable, possible, or excluded) and therapeutic plans (antibiotic initiation/discontinuation, hospitalization/discharge) were established by emergency physicians before and after CT scan results. The adjudication committee established the final CAP classification on Day 28. Chest radiograph revealed a parenchymal infiltrate in 188 patients. CAP was initially classified as definite in 143 patients (44.8%), probable or possible in 172 (53.8%), and excluded in 4 (1.2%). CT scan revealed a parenchymal infiltrate in 40 (33%) of the patients without infiltrate on chest radiograph and excluded CAP in 56 (29.8%) of the 188 with parenchymal infiltrate on radiograph. CT scan modified classification in 187 (58.6%; 95% confidence interval, 53.2-64.0), leading to 50.8% definite CAP and 28.8% excluded CAP, and 80% of modifications were in accordance with adjudication committee classification. Because of CT scan, antibiotics were initiated in 51 (16%) and discontinued in 29 (9%), and hospitalization was decided in 22 and discharge in 23. In CAP-suspected patients visiting the emergency unit, early CT scan findings complementary to chest radiograph markedly affect both diagnosis and clinical management. Clinical trial registered with www.clinicaltrials.gov (NCT 01574066).

  4. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    Science.gov (United States)

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  5. Fluorodeoxyglucose positron emission tomography-computed tomography scan in von Hippel-Lindau syndrome: a case report and review of literature

    International Nuclear Information System (INIS)

    Solav, Shrikant; Bhandari, Ritu

    2012-01-01

    Von Hippel-Lindau (VHL) syndrome is a hereditary autosomal dominant disorder caused by defective tumor suppression gene at 3p25-p26. The gene for VHL disease is found on chromosome 3, and is inherited in a dominant fashion. The VHL gene is a tumor suppressor gene. This means that its role in a normal cell is to stop the uncontrolled growth and proliferation. It is characterized by abnormal growth of blood vessels. It strikes the eyes, central nervous system, kidneys, endocrine glands, etc. It predisposes the patient to retinal angiomas, central nervous system hemangioblastoma, renal cell carcinoma (RCC), pheochromocytomas, islet cell tumor of the pancreas, endolymphatic sac tumors, renal, pancreatic, epididymal cysts. We present a case of familial VHL syndrome whose Fluorine 18-fluorodeoxyglucose positron emission tomography-computed tomography scan was truly positive for adrenal pheochromocytoma but was falsely negative for RCC. Review of literature related to this entity is made. (author)

  6. Is a positron emission tomography-computed tomography scan useful in the staging of thymic epithelial neoplasms?

    Science.gov (United States)

    Viti, Andrea; Terzi, Alberto; Bianchi, Andrea; Bertolaccini, Luca

    2014-07-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed concerned the employment of 18-fluorine fluorodeoxyglucose positron emission tomography/computed tomography (PET-CT) in the preoperative evaluation of thymic epithelial neoplasms (TENs). We reviewed its role as a predictor of Masaoka stage and histology (according to the WHO). In clinical practice, stage is considered the most important determinant in the therapeutic approach. A total of 265 papers were found as a result of the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. All the studies are retrospective analyses. Patient numbers varied from 13 to 58. Our research showed that PET-CT could clearly add information about the histology of the tumour. Thymic carcinoma constantly showed a higher standard uptake value (SUVmax) than thymomas. Furthermore, in one retrospective study of 36 patients, when using a derived PET indicator, the T/M ratio (ratio between SUVmax of the tumour and SUVmax of mediastinum, as conventionally measured at the level of the aortic arc), PET-CT could also differentiate between low- and high-risk thymomas (low risk vs high risk P = 0.01). In another study, a cut-off value of T/M ratio of 2.75 was identified between low- and high-risk TENs. The role of PET-CT in prediction of stage is harder to recognize. In one study, there was a statistically significant correlation between SUVmax, T/M ratio and Masaoka stage (P = 0.781 and 0.718, respectively). When analysing the data from the three larger series on this topic (58, 51 and 47 patients, the latter group selected in a multicentre study), only one study identified a correlation between SUVmax and Masaoka stage (Spearman correlation coefficient 0.30, P = 0.0436), while the other two failed

  7. Comparison of positions of the trochlear groove line and the vertical midline of the pericondylar rectangle on axial computed tomography: a retrospective pilot study

    International Nuclear Information System (INIS)

    Nizic, Dinko

    2012-01-01

    To compare the positions of the trochlear groove (TG) line and the vertical midline of the pericondylar rectangle on axial computed tomography (CT). A retrospective pilot study was conducted in February and March 2011 comprising 14 knees in 9 consecutive patients with patellofemoral pain, a normal trochlear angle (124 -145 ), and no medical record of prior knee surgery. After the axial CT image displaying the center of the trochlear groove (''reference cut'') with a normal trochlear angle was identified, the pericondylar rectangle was drawn and located in the first quadrant of the Cartesian rectangular coordinate system. The x-coordinates of the vertical lines passing through the most posterior point of the trochlear groove (TG line) and the midpoints of the horizontal sides of the pericondylar rectangle (vertical midline) were obtained at 2-week intervals and statistically analyzed as matched pairs for differences (Wilcoxon signed rank test), agreements (Bland-Altman plot, intraclass correlation coefficient [ICC]) and relative variations (coefficient of variation [CV]). There were no statistically significant differences between matched pairs (2-tailed p from 0.583 to 0.641) whereas the agreements were substantial (bias = -0.37 and -0.45 respectively, ICC = 0.688 and 0.670 respectively) to almost perfect for duplicate measurements (bias = 0.11 and 0.04 respectively, ICC = 0.975 and 0.998 respectively), with much less relative variation with regard to the vertical midline (CV = 1.22% to CV = 0.34% respectively). The positions of the TG line and the vertical midline of the pericondylar rectangle on axial CT were identical. The latter was identified regardless of trochlear morphology. (orig.)

  8. Comparison of positions of the trochlear groove line and the vertical midline of the pericondylar rectangle on axial computed tomography: a retrospective pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nizic, Dinko [Zagreb University Hospital Center, Clinical Institute of Diagnostic and Interventional Radiology, Zagreb (Croatia)

    2012-09-15

    To compare the positions of the trochlear groove (TG) line and the vertical midline of the pericondylar rectangle on axial computed tomography (CT). A retrospective pilot study was conducted in February and March 2011 comprising 14 knees in 9 consecutive patients with patellofemoral pain, a normal trochlear angle (124 -145 ), and no medical record of prior knee surgery. After the axial CT image displaying the center of the trochlear groove (''reference cut'') with a normal trochlear angle was identified, the pericondylar rectangle was drawn and located in the first quadrant of the Cartesian rectangular coordinate system. The x-coordinates of the vertical lines passing through the most posterior point of the trochlear groove (TG line) and the midpoints of the horizontal sides of the pericondylar rectangle (vertical midline) were obtained at 2-week intervals and statistically analyzed as matched pairs for differences (Wilcoxon signed rank test), agreements (Bland-Altman plot, intraclass correlation coefficient [ICC]) and relative variations (coefficient of variation [CV]). There were no statistically significant differences between matched pairs (2-tailed p from 0.583 to 0.641) whereas the agreements were substantial (bias = -0.37 and -0.45 respectively, ICC = 0.688 and 0.670 respectively) to almost perfect for duplicate measurements (bias = 0.11 and 0.04 respectively, ICC = 0.975 and 0.998 respectively), with much less relative variation with regard to the vertical midline (CV = 1.22% to CV = 0.34% respectively). The positions of the TG line and the vertical midline of the pericondylar rectangle on axial CT were identical. The latter was identified regardless of trochlear morphology. (orig.)

  9. Nasal Anthropometry on Facial Computed Tomography Scans for Rhinoplasty in Koreans

    Directory of Open Access Journals (Sweden)

    Kyung Min Moon

    2013-09-01

    Full Text Available BackgroundCephalometric analysis is essential for planning treatment in maxillofacial and aesthetic facial surgery. Although photometric analysis of the Korean nose has been attempted in the past, anthropometry of the deeper nasal structures in the same population based on computerized tomography (CT has not been published. We therefore measured three anthropometric parameters of the nose on CT scans in our clinical series of patients.MethodsWe conducted the current retrospective study of a total of 100 patients (n=100 who underwent a CT-guided radiological measurement at our institution during a period ranging from January of 2008 to August of 2010. In these patients, we took three anthropometric measurements: the nasofrontal angle, the pyramidal angle, and the linear distance between the nasion and the tip of the nasal bone.ResultsThe mean nasofrontal angle was 131.14° in the male patients and 140.70° in the female patients. The mean linear distance between the nasion and the tip of the nasal bone was 21.28 mm and 18.02 mm, respectively. The mean nasal pyramidal angle was 112.89° and 103.25° at the level of the nasal root, 117.49° and 115.60° at the middle level of the nasal bone, and 127.99° and 125.04° at the level of the tip of the nasal bone, respectively.ConclusionsIn conclusion, our data will be helpful in the preparation of silicone implants for augmentation and/or corrective rhinoplasty in ethnic Korean people.

  10. Spontaneous Acute Mesenteroaxial Gastric Volvulus Diagnosed by Computed Tomography Scan in a Young Man.

    Science.gov (United States)

    Jabbour, Gaby; Afifi, Ibrahim; Ellabib, Mohamed; El-Menyar, Ayman; Al-Thani, Hassan

    2016-04-26

    Acute gastric volvulus is a surgical emergency that requires early recognition and treatment. Acute idiopathic mesenteroaxial gastric volvulus is a rare sub-type and there are few cases reported in children and there are even fewer reports in adults. We report a rare case of a 23-year-old man who presented with a 1-day history of vomiting, epigastric pain, distention, and constipation. The diagnosis for mesenteroaxial type gastric volvulus was confirmed by abdominal radiography and computed tomography. The patient was successfully treated by laparotomy with resection of the ischemic stomach wall and anastomosis. Acute spontaneous mesenteroaxial gastric volvulus is rare in adults and early diagnosis is challenging due to non-specific symptoms. A missed or delayed diagnosis may result in serious complications due to gastric obstruction. A patient presenting with severe epigastric pain and clinical evidence of gastric outlet obstruction should be considered as a surgical emergency to rule out gastric volvulus. High index of suspicion, early diagnosis and prompt surgical management are important for favorable outcome in patients with acute spontaneous gastric volvulus.

  11. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  12. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions.

    Science.gov (United States)

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-05-01

    To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

  13. Dose profile in computed tomography chest scan; Perfil de dose em varredura de torax em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno B., E-mail: bbo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais; Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil); Alonso, Thessa C.; Silva, Teogenes A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2010-07-01

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58{+-}5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  14. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    Science.gov (United States)

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken. PMID:27226958

  15. Registration area and accuracy when integrating laser-scanned and maxillofacial cone-beam computed tomography images.

    Science.gov (United States)

    Sun, LiJun; Hwang, Hyeon-Shik; Lee, Kyung-Min

    2018-03-01

    The purpose of this study was to examine changes in registration accuracy after including occlusal surface and incisal edge areas in addition to the buccal surface when integrating laser-scanned and maxillofacial cone-beam computed tomography (CBCT) dental images. CBCT scans and maxillary dental casts were obtained from 30 patients. Three methods were used to integrate the images: R1, only the buccal and labial surfaces were used; R2, the incisal edges of the anterior teeth and the buccal and distal marginal ridges of the second molars were used; and R3, labial surfaces, including incisal edges of anterior teeth, and buccal surfaces, including buccal and distal marginal ridges of the second molars, were used. Differences between the 2 images were evaluated by color-mapping methods and average surface distances by measuring the 3-dimensional Euclidean distances between the surface points on the 2 images. The R1 method showed more discrepancies between the laser-scanned and CBCT images than did the other methods. The R2 method did not show a significant difference in registration accuracy compared with the R3 method. The results of this study indicate that accuracy when integrating laser-scanned dental images into maxillofacial CBCT images can be increased by including occlusal surface and incisal edge areas as registration areas. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  16. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  17. Computerized axial tomography in traumatic cervical lesions

    International Nuclear Information System (INIS)

    Koyama, Tsunemaro

    1982-01-01

    Although plain computerized axial tomography cannot routinely demonstrate the spinal cord, it does provide excellent visualization of the bony outline of the spinal canal and vertebral column. So it should be reasonable to use this technique in cases of cervical traumatic disorders. In this paper we presented 10 cases of cervical traumatic lesions; 3 atlanto-axial dislocation, 2 cervical canal stenosis, 3 OPLL, 1 intramedullary hematoma and 1 C 2 -neurinoma. In some patients neurologic deficits were induced by cervical trauma. Bony lesions appeared more adequately deliniated than intraspinal lesions, however, in some cases intramedullary changes could also be demonstrated. The use of metrizamide with high resolution CT-scanner could improve the usefullness of this technique. (author)

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  19. Estimation of air void and aggregate spatial distributions in concrete under uniaxial compression using computer tomography scanning

    International Nuclear Information System (INIS)

    Wong, R.C.K.; Chau, K.T.

    2005-01-01

    Normal- and high-strength concrete cylinders (designed compressive strengths of 30 and 90 MPa at 28 days) were loaded uniaxially. Computer tomography (CT) scanning technique was used to examine the evolution of air voids inside the specimens at various loading states up to 85% of the ultimate compressive strength. The normal-strength concrete yielded a very different behaviour in changes of internal microstructure as compared to the high-strength concrete. There were significant instances of nucleation and growth in air voids in the normal-strength concrete specimen, while the increase in air voids in the high-strength concrete specimen was insignificant. In addition, CT images were used for mapping the aggregate spatial distributions within the specimens. No intrinsic anisotropy was detected from the fabric analysis

  20. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  1. Serial cranial computed-tomography scans in children with leukemia given two different forms of central nervous system therapy

    International Nuclear Information System (INIS)

    Ochs, J.J.; Parvey, L.S.; Whitaker, J.N.; Bowman, W.P.; Ch'ien, L.; Campbell, M.; Coburn, T.

    1983-01-01

    Cranial computed tomography (CT) was used to estimate the frequency and permanence of brain abnormalities in 108 consecutive children with acute lymphoblastic leukemia (ALL). Fifty-five patients received cranial irradiation (1,800 rad) with intrathecal methotrexate (RT group) and 53 patients received intravenous and intrathecal methotrexate without irradiation (IVIT group). Continuation treatment included sequential drug pairs for the RT group and periodic IVIT methotrexate for the other group. After 12 to 24 months of serial evaluation, five (9%) of the 55 patients in the RT group have had CT scan abnormalities, compared to 10 (19%) of 52 in the IVIT group (p . 0.171). Fourteen of the 15 patients with CT scan abnormalities had focal or diffuse white-matter hypodensity; these have reverted to normal in most cases, reflecting a dynamic process. While such CT findings are of concern and may be an early indicator of central nervous system toxicity, this remains to be proven. Therapy should not be altered on the basis of abnormal CT scans alone but in the context of the entire clinical situation

  2. Evaluating the periapical status of teeth with irreversible pulpitis by using cone-beam computed tomography scanning and periapical radiographs.

    Science.gov (United States)

    Abella, Francesc; Patel, Shanon; Duran-Sindreu, Fernando; Mercadé, Montse; Bueno, Rufino; Roig, Miguel

    2012-12-01

    The purpose of this study was to compare the prevalence of apical periodontitis (AP) on individual roots of teeth with irreversible pulpitis viewed with periapical (PA) radiographs and cone-beam computed tomography (CBCT) scans. PA radiographs and CBCT scans were taken of 138 teeth in 130 patients diagnosed with irreversible pulpitis (symptomatic and asymptomatic). Two calibrated examiners assessed the presence or absence of AP lesions by analyzing the PA and CBCT images. A consensus was reached in the event of any disagreement. The data were analyzed using the hypothesis test, and significance was set at P ≤ .05. Three hundred seven paired roots were assessed with both PA and CBCT images. A comparison of the 307 paired roots revealed that AP lesions were present in 10 (3.3%) and absent in 297 (96.7%) pairs of roots when assessed with PA radiography. When the same 307 sets of roots were assessed with CBCT scans, AP lesions were present in 42 (13.7%) and absent in 265 (86.3%) paired roots. The prevalence of AP lesions detected with CBCT was significantly higher in the symptomatic group compared with the asymptomatic group (P < .05). An additional 22 roots were identified with CBCT alone. The present study highlights the advantages of using CBCT for detecting AP lesions, especially in teeth with symptomatic irreversible pulpitis. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Sudden headache, lumbar puncture, and the diagnosis of subarachnoid hemorrhage in patients with a normal computed tomography scans.

    Science.gov (United States)

    Valle Alonso, Joaquín; Fonseca Del Pozo, Francisco Javier; Vaquero Álvarez, Manuel; De la Fuente Carillo, Juan José; Llamas, José Carlos; Hernández Montes, Yelda

    2018-02-01

    To assess the usefulness of computed tomography (CT) to identify subarachnoid bleeding in patients with neurologic deficits seeking emergency care for sudden headache within 6 hours of onset of symptoms. Retrospective observational study of patients presenting with sudden nontraumatic headache peaking during the previous hour in the absence of neurologic deficits. We ordered CT scans for all patients, and if the scan was normal we performed a lumbar puncture. All patients were then followed for 6 months. Eighty-five patients were included. Subarachnoid bleeding was identified in 10 (10.2%) patients by CT. Seventy- four lumbar punctures were performed in patients with negative CTs; the lumbar puncture was positive in 1 patient and inconclusive in 2 patients. In all 3 patients, bleeding was ruled out with later images; thus, no cases of subarachnoid hemorrhage were confirmed in the 74 patients who underwent lumbar puncture. Nor were any cases found in any of these patients during follow-up. A CT scan taken within 6 hours of onset of sudden headache is sufficient for confirming or ruling out subarachnoid bleeding in patients with sudden headache who have no neurologic deficits.

  4. Please Don't Move-Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features.

    Science.gov (United States)

    Rantalainen, Timo; Chivers, Paola; Beck, Belinda R; Robertson, Sam; Hart, Nicolas H; Nimphius, Sophia; Weeks, Benjamin K; McIntyre, Fleur; Hands, Beth; Siafarikas, Aris

    Most imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans. However, previously reported objective methods either cannot be applied on the reconstructed image or have not been tested for distal bone sites. Therefore, the purpose of the present study was to develop and validate motion artifact classifiers to quantify motion artifact in pQCT scans. Whether textural features could provide adequate motion artifact classification performance in 2 adolescent datasets with pQCT scans from tibial and radial diaphyses and epiphyses was tested. The first dataset was split into training (66% of sample) and validation (33% of sample) datasets. Visual classification was used as the ground truth. Moderate to substantial classification performance (J48 classifier, kappa coefficients from 0.57 to 0.80) was observed in the validation dataset with the novel texture-based classifier. In applying the same classifier to the second cross-sectional dataset, a slight-to-fair (κ = 0.01-0.39) classification performance was observed. Overall, this novel textural analysis-based classifier provided a moderate-to-substantial classification of motion artifact when the classifier was specifically trained for the measurement device and population. Classification based on textural features may be used to prescreen obviously acceptable and unacceptable scans, with a subsequent human-operated visual classification of any remaining scans. Copyright © 2017 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  5. Trends and patterns of computed tomography scan use among children in The Netherlands: 1990-2012

    International Nuclear Information System (INIS)

    Meulepas, Johanna M.; Gradowska, Patrycja; Kieft, Mariette; Hauptmann, Michael; Smets, Anne M.J.B.; Nievelstein, Rutger A.J.; Verbeke, Jonathan; Holscher, Herma C.; Rutten, Matthieu J.C.M.; Ronckers, Cecile M.

    2017-01-01

    To evaluate trends and patterns in CT usage among children (aged 0-17 years) in The Netherlands during the period 1990-2012. Lists of electronically archived paediatric CT scans were requested from the Radiology Information Systems (RIS) of Dutch hospitals which reported >10 paediatric CT scans annually in a survey conducted in 2010. Data included patient identification, birth date, gender, scan date and body part scanned. For non-participating hospitals and for years prior to electronic archiving in some participating hospitals, data were imputed by calendar year and hospital type (academic, general with <500 beds, general with ≥ 500 beds). Based on 236,066 CT scans among 146,368 patients performed between 1990 and 2012, estimated annual numbers of paediatric CT scans in The Netherlands increased from 7,731 in 1990 to 26,023 in 2012. More than 70 % of all scans were of the head and neck. During the last decade, substantial increases of more than 5 % per year were observed in general hospitals with fewer than 500 beds and among children aged 10 years or older. The estimated number of paediatric CT scans has more than tripled in The Netherlands during the last two decades. (orig.)

  6. Trends and patterns of computed tomography scan use among children in The Netherlands: 1990-2012

    Energy Technology Data Exchange (ETDEWEB)

    Meulepas, Johanna M.; Gradowska, Patrycja; Kieft, Mariette; Hauptmann, Michael [Netherlands Cancer Institute, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Smets, Anne M.J.B. [Academic Medical Center Amsterdam, Department of Radiology, Amsterdam (Netherlands); Nievelstein, Rutger A.J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Verbeke, Jonathan [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Holscher, Herma C. [HAGA Hospital/Juliana Children' s Hospital, Department of Radiology, The Hague (Netherlands); Rutten, Matthieu J.C.M. [Jeroen Bosch Hospital, Department of Radiology, ' s Hertogenbosch (Netherlands); Ronckers, Cecile M. [Academic Medical Center Amsterdam, Department of Paediatric Oncology Emma Children' s Hospital, Amsterdam (Netherlands)

    2017-06-15

    To evaluate trends and patterns in CT usage among children (aged 0-17 years) in The Netherlands during the period 1990-2012. Lists of electronically archived paediatric CT scans were requested from the Radiology Information Systems (RIS) of Dutch hospitals which reported >10 paediatric CT scans annually in a survey conducted in 2010. Data included patient identification, birth date, gender, scan date and body part scanned. For non-participating hospitals and for years prior to electronic archiving in some participating hospitals, data were imputed by calendar year and hospital type (academic, general with <500 beds, general with ≥ 500 beds). Based on 236,066 CT scans among 146,368 patients performed between 1990 and 2012, estimated annual numbers of paediatric CT scans in The Netherlands increased from 7,731 in 1990 to 26,023 in 2012. More than 70 % of all scans were of the head and neck. During the last decade, substantial increases of more than 5 % per year were observed in general hospitals with fewer than 500 beds and among children aged 10 years or older. The estimated number of paediatric CT scans has more than tripled in The Netherlands during the last two decades. (orig.)

  7. A review of the benefits and rationale of viewing liver window settings for abdominal computed tomography scans

    International Nuclear Information System (INIS)

    Dang, Tan; Mandarano, Giovanni

    2006-01-01

    There have been many different opinions over the efficacy of routinely incorporating liver-window settings in abdominal computed tomography (CT) scans. As a result, different clinical centres have varying protocols for incorporating liver-windows for abdominal CT scans. This investigation aims to explore and determine whether various clinical centres throughout Victoria use liver-window settings selectively or routinely and their justification for doing so. An additional purpose is also to assess the benefits and rationale of liver-window settings in supplementing routine soft-tissue-windows for abdominal CT examinations by reviewing evidenced-based studies. Surveys were sent out to CT supervisors at various clinical centres, including private and public institutions. This achieved an overall response rate of 74 per cent. Results indicate that the majority of clinical centres throughout Victoria routinely incorporate liver-window settings for all abdominal CT examinations. Forty four per cent (11/25) of respondents stated that they utilise liver-window settings selectively for abdominal CT examinations. Most of these respondents (7/11 = 63 per cent) believed that soft-tissue-window settings alone are adequate to demonstrate hepatic lesions; particularly if intravenous contrast media is used and the liver is captured in the arterial, venous and/or delayed phases. The benefits and rationale of incorporating liver-window settings for all abdominal computed tomography scans has been questioned by two well noted studies in the United States. These evidence-based studies suggest that such additional settings do not offer further advantages in detecting hepatic disease, when compared to soft-tissue-windows alone. Review of the available literature provides additional evidence suggesting that the routine use of liver-window settings in conjunction with soft-tissue-windows offers no further advantages in the detection of hepatic diseases. This investigation found, however

  8. Fan-beam scanning laser optical computed tomography for large volume dosimetry

    Science.gov (United States)

    Dekker, K. H.; Battista, J. J.; Jordan, K. J.

    2017-05-01

    A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations.

  9. Fan-beam scanning laser optical computed tomography for large volume dosimetry

    International Nuclear Information System (INIS)

    Dekker, K H; Battista, J J; Jordan, K J

    2017-01-01

    A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations. (paper)

  10. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  12. Radiology of pulmonary disease. Chest radiography, computed tomography, and gallium scanning

    International Nuclear Information System (INIS)

    Golden, J.A.; Sollitto, R.A.

    1988-01-01

    A review of the radiologic manifestations of AIDS pulmonary diseases, with an emphasis on the utility of gallium scanning in the context of the normal or equivocal chest x-ray, is presented.99 references

  13. Trends and patterns of computed tomography scan use among children in The Netherlands: 1990-2012.

    Science.gov (United States)

    Meulepas, Johanna M; Smets, Anne M J B; Nievelstein, Rutger A J; Gradowska, Patrycja; Verbeke, Jonathan; Holscher, Herma C; Rutten, Matthieu J C M; Kieft, Mariëtte; Ronckers, Cécile M; Hauptmann, Michael

    2017-06-01

    To evaluate trends and patterns in CT usage among children (aged 0-17 years) in The Netherlands during the period 1990-2012. Lists of electronically archived paediatric CT scans were requested from the Radiology Information Systems (RIS) of Dutch hospitals which reported >10 paediatric CT scans annually in a survey conducted in 2010. Data included patient identification, birth date, gender, scan date and body part scanned. For non-participating hospitals and for years prior to electronic archiving in some participating hospitals, data were imputed by calendar year and hospital type (academic, general with Netherlands increased from 7,731 in 1990 to 26,023 in 2012. More than 70 % of all scans were of the head and neck. During the last decade, substantial increases of more than 5 % per year were observed in general hospitals with fewer than 500 beds and among children aged 10 years or older. The estimated number of paediatric CT scans has more than tripled in The Netherlands during the last two decades. • Paediatric CT in The Netherlands has tripled during the last two decades. • The number of paediatric CTs increased through 2012 in general hospitals. • Paediatric CTs continued to increase among children aged 10 years or older.

  14. Sensitivity of computer assisted radionuclide angiography in transient ischemic attack and prolonged reversible ischemic neurological deficit. Comparison with findings in radiographic angiography and transmission computerized axial tomography

    International Nuclear Information System (INIS)

    Buell, U.; Scheid, K.F.; Lanksch, W.; Kleinhans, E.; Ulbert, V.; Reger, U.; Rath, M.; Moser, E.A.

    1981-01-01

    Computer assisted radionuclide angiography (CARNA) with 99mTc-DTPA was employed to study 143 patients with transient ischemic attacks (TIA) and 79 patients with prolonged reversible ischemic neurologic deficit (PRIND). The results of CARNA were compared with findings from radiographic angiography (RGA) in 173 patients and with findings in transmission computerized axial tomography (T-CAT) in 154 patients. In patients with TIA, CARNA showed a hemispherical perfusion deficit in 74.8%, and with PRIND 87.3%. This deficit, determined as the relative difference between the involved and the non-involved hemisphere, was significantly (p less than 0.0025) greater in PRIND (minus 23%) than in TIA (minus 17%). Sensitivity of CARNA was independent of the interval from ictus to examination for more than 4 months. RGA in TIA revealed true positives in 82.0%, in PRIND it was 89.5%. T-CAT was positive in TIA in only 16.8% but in PRIND it was 64.4%. Combined sensitivities in TIA (92.4%) and in PRIND (94.0%) were highest with the combination of CARNA and RGA. However, in PRIND the combination of non-invasive methods (CARNA and T-CAT) revealed 93.2% positive findings. Combinations of these evaluation methods may be used to detect cerebrovascular disease in patients with such dysfunction

  15. Neurologic, neuropsychologic, and computed cranial tomography scan abnormalities in 2- to 10-year survivors of small-cell lung cancer.

    Science.gov (United States)

    Johnson, B E; Becker, B; Goff, W B; Petronas, N; Krehbiel, M A; Makuch, R W; McKenna, G; Glatstein, E; Ihde, D C

    1985-12-01

    In order to evaluate the relationship between neurologic function and cranial irradiation, 20 patients treated on National Cancer Institute (NCI) small-cell lung cancer (SCLC) trials who were alive and free of cancer 2.4 to 10.6 years (median, 6.2) from the start of therapy were studied. All were tested with a neurologic history and examination, mental status examination, neuropsychologic testing, and review of serial computed cranial tomography (CCT) scans. Fifteen patients had been treated with prophylactic cranial irradiation (PCI), two patients with therapeutic cranial irradiation, and three received no cranial irradiation. All patients but one were ambulatory and none were institutionalized. Fifteen patients (75%) had neurologic complaints, 13 (65%) had abnormal neurologic examinations, 12 (60%) had abnormal mental status examinations, 13 (65%) had abnormal neuropsychologic testing, and 15 (75%) had abnormal CCT scans. Compared with those given low-dose maintenance chemotherapy during PCI using 200 to 300 rad per fraction, patients who were given high-dose induction chemotherapy during the time of cranial irradiation or large radiotherapy fractions (400 rad) were more likely to have abnormal mental status examinations (6/6 v 4/9) and abnormal neuropsychologic tests (6/6 v 4/9), but no major difference in CCT findings was present. CCT scans in the majority of cases (11/18) showed progressive ventricular dilatation or cerebral atrophy up to 8 years after stopping therapy. We conclude neurologic abnormalities are common in long-term survivors of SCLC, and may be more prominent in patients given high-dose chemotherapy during cranial irradiation or treated with large radiotherapy fractions. The CCT scan abnormalities are common and progressive years after prophylactic cranial irradiation and chemotherapy are stopped.

  16. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  17. Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

    International Nuclear Information System (INIS)

    Tasanapanont, Jintana; Apisariyakul, Janya; Wattanachai, Tanapan; Jotikasthira, Dhirawat; Sriwilas, Patiyut; Midtboe, Marit

    2017-01-01

    The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient (ICC) was used to assess intraobserver reliability. The root surface area measurements (230.11±41.97 mm"2) obtained using CBCT were slightly greater than those (229.31±42.46 mm2) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth

  18. Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tasanapanont, Jintana; Apisariyakul, Janya; Wattanachai, Tanapan; Jotikasthira, Dhirawat [Dept. of Orthodontics and Pediatric Dentistry, Faculty of Dentistry, Chiang Mai University, Chiang Mai (Thailand); Sriwilas, Patiyut [Dept. of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok (Thailand); Midtboe, Marit [Dept. of Clinical Dentistry - Orthodontics, Faculty of Medicine and Dentistry, University of Bergen, Bergen (Norway)

    2017-06-15

    The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient (ICC) was used to assess intraobserver reliability. The root surface area measurements (230.11±41.97 mm{sup 2}) obtained using CBCT were slightly greater than those (229.31±42.46 mm2) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

  19. [Application of second generation dual-source computed tomography dual-energy scan mode in detecting pancreatic adenocarcinoma].

    Science.gov (United States)

    Xue, Hua-dan; Liu, Wei; Sun, Hao; Wang, Xuan; Chen, Yu; Su, Bai-yan; Sun, Zhao-yong; Chen, Fang; Jin, Zheng-yu

    2010-12-01

    To analyze the clinical value of multiple sequences derived from dual-source computed tomography (DSCT) dual-energy scan mode in detecting pancreatic adenocarcinoma. Totally 23 patients with clinically or pathologically diagnosed pancreatic cancer were enrolled in this retrospective study. DSCT (Definition Flash) was used and dual-energy scan mode was used in their pancreatic parenchyma phase scan (100kVp/230mAs and Sn140kVp/178mAs) . Mono-energetic 60kev, mono-energetic 80kev, mono-energetic 100kev, mono-energetic 120kev, linear blend image, non-linear blend image, and iodine map were acquired. pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were calculated. One-way ANOVA was used for the comparison of diagnostic values of the above eight different dual-energy derived sequences for pancreatic cancer. The pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were significantly different among eight sequences (P<0.05) . Mono-energetic 60kev image showed the largest parenchyma-tumor CT value [ (77.53 ± 23.42) HU] , and iodine map showed the lowest tumor/parenchyma enhancement ratio (0.39?0.12) and the largest contrast to noise ratio (4.08 ± 1.46) . Multiple sequences can be derived from dual-energy scan mode with DSCT via multiple post-processing methods. Integration of these sequences may further improve the sensitivity of the multislice spiral CT in the diagnosis of pancreatic cancer.

  20. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  1. Dose comparison of different scan projections of Implagraphy cone beam computed tomography for dental maxillofacial use

    International Nuclear Information System (INIS)

    Fang Dong; Yuan Xianshun; Zhang Dongsheng

    2012-01-01

    Objective: To evaluate the subject's absorbed dose,equivalent dose and effective dose. Methods: The CBCT unit was Implagraphy and three scan projections were selected such as mandible, maxilla and temporomandibular joint (TMJ). Thermoluminescent dosimeter tubes were used to record the absorbed dose at special positions in the head and neck region of an adult skull and tissue-equivalent phantom. 16 interested organs included pituitary, lens, parotid glands, submandibular glands, sublingual glands, diploe, spongy bone of the chin and cervical vertebra, skins of cheeks and nuchal region, thyroid and esophagus. The absorbed dose was measured in these organs, and then the effective dose (E 1990 , E 2007 ) were calculated according to different ICRP tissue weighting factors. Results: The absorbed dose of mandible,maxilla and TMJ scan varied from (0.99 ±0.09) to (12.85 ±0.09)mGy, (0.93 ±0.01) to (13.07 ±0.02) mGy and (0.68 ±0.01) to (10.18 ± 0.04)mGy. There was significant difference among the three scan projections (F=19.61-30992.27, P<0.05). The equivalent doses of lens and skin were (1.11± 0.07)-(5.76 ± 0.06) mSv and (6.96 ± 0.06)-(10.64 ± 0.07) mSv. There was significant difference among the three scan projections (F=4473.02, 9385.50, P<0.05). The effective dose (E 1990 , E 2007 ) was [(191.35±1.53), (325.17 ±2.58) μSv] for mandible scan, [(106.62 ±2.17), (226.28 ±2.81) μSv] for maxilla scan, [(104.21 ± 1.02), (142.36 ± 1.90) μSv]for TMJ scan, respectively. Conclusions: The valid measurement should be taken to reduce the subject's dose such as a careful history and clinical examination before the performance of CBCT, the latest risk/benefit assessment,precise scan position, the shielding of thyroid as well as brain and the smaller volume size as well. (authors)

  2. Abdominal fat-evaluation by use of single scan computed tomography; Computertomographische Bestimmung des intraabdominellen Fettvolumens mittels Einschicht-Messung

    Energy Technology Data Exchange (ETDEWEB)

    Jacobi, V. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Steinkamp, M. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Kirchner, J. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Fischer, H. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik; Diedrich, C.F. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik; Kollath, J. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik

    1997-02-01

    Purpose: Several studies emphasised the importance of the relationship between intraabdominal and total body adipose tissue as a risk factor for the development of metabolic or cardiovascular diseases. Therefore, the aim of the present study was to examine whether a single scan computed tomography is able to determine the whole intraabdominal fat volume with high accuracy and reproducibility. Materials and methods: Regions of interests (ROIs) were drawn manually for measuring intraabdominal fat in 51 unsuspicious abdominal CT. Results: The sexual differentiation of adipose tissue already described in a lot of studies could be confirmed in this study. Fat still predominates in females in lower half of the body (gynoid obesity). In men it predominates in the upper half (android obesity). Significant correlation concerning measuring the whole intraabdominal fat volume could be found in L1-level in women (r=0.992) and in L2-level in men (r=0.992). Measurement of a single scan enables us to assess whole intraabdominal fat volume due to a special formula. Conclusion: The determination of intraabdominal fat measured by a single scan computed tomography is a procedure associated with high accuracy and reproducibility. (orig.) [Deutsch] Ziel: Da in zahlreichen Studien hervorgehobene Bedeutung des intraabdominellen Fettgewebes gegenueber dem Gesamtkoerperfett als Risikofaktor fuer die Entwicklung metabolischer und kardiovaskulaerer Erkrankungen fordert ein Verfahren zur annaehernd exakten Bestimmung des intraabdominellen Fettgewebes. Ziel der vorliegenden Studie war zu pruefen, ob mit genuegender Genauigkeit die Verwendung einer Einschicht-Methode einen gezielten Einsatz der Computertomographie ermoeglicht und welche Lokalisation der zu waehlenden Schicht die aussagekraeftigste Messung ermoeglicht. Material und Methode: Anhand von 51 Computertomographien des Abdomens anderer Indikation (Normalbefunde) wurde das gesamte intraabdominelle Fettvolumen semiautomatisch mittels ROI

  3. Three-dimensional analysis of rodent paranasal sinus cavities from X-ray computed tomography (CT) scans

    Science.gov (United States)

    Phillips, Jonathan E.; Ji, Lunan; Rivelli, Maria A.; Chapman, Richard W.; Corboz, Michel R.

    2009-01-01

    Continuous isometric microfocal X-ray computed tomography (CT) scans were acquired from an AKR/J mouse, Brown-Norway rat, and Hartley guinea pig. The anatomy and volume of the paranasal sinus cavities were defined from 2-dimensional (2-D) and 3-dimensional (3-D) CT images. Realistic 3-D images were reconstructed and used to determine the anterior maxillary, posterior maxillary, and ethmoid sinus cavity airspace volumes (mouse: 0.6, 0.7, and 0.7 mm3, rat: 8.6, 7.7, and 7.0 mm3, guinea pig: 63.5, 46.6 mm3, and no ethmoid cavity, respectively). The mouse paranasal sinus cavities are similar to the corresponding rat cavities, with a reduction in size, while the corresponding maxillary sinus cavities in the guinea pig are different in size, location, and architecture. Also, the ethmoid sinus cavity is connected by a common drainage pathway to the posterior maxillary sinus in mouse and rat while a similar ethmoid sinus was not present in the guinea pig. We conclude that paranasal sinus cavity airspace opacity (2-D) or volume (3-D) determined by micro-CT scanning may be used to conduct longitudinal studies on the patency of the maxillary sinus cavities of rodents. This represents a potentially useful endpoint for developing and testing drugs in a small animal model of sinusitis. PMID:19794893

  4. Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: Pilot study

    International Nuclear Information System (INIS)

    Li Ping; Napel, Sandy; Acar, Burak; Paik, David S.; Jeffrey, R. Brooke Jr.; Beaulieu, Christopher F.

    2004-01-01

    Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wall to be collapsed, covered with water, and/or covered with retained stool, patients are scanned in both prone and supine positions. We believe that both reading efficiency and computer aided detection (CAD) of CTC images can be improved by accurate registration of data from the supine and prone positions. We developed a two-stage approach that first registers the colonic central paths using a heuristic and automated algorithm and then matches polyps or polyp candidates (CAD hits) by a statistical approach. We evaluated the registration algorithm on 24 patient cases. After path registration, the mean misalignment distance between prone and supine identical anatomic landmarks was reduced from 47.08 to 12.66 mm, a 73% improvement. The polyp registration algorithm was specifically evaluated using eight patient cases for which radiologists identified polyps separately for both supine and prone data sets, and then manually registered corresponding pairs. The algorithm correctly matched 78% of these pairs without user input. The algorithm was also applied to the 30 highest-scoring CAD hits in the prone and supine scans and showed a success rate of 50% in automatically registering corresponding polyp pairs. Finally, we computed the average number of CAD hits that need to be manually compared in order to find the correct matches among the top 30 CAD hits. With polyp registration, the average number of comparisons was 1.78 per polyp, as opposed to 4.28 comparisons without polyp registration

  5. Surgical outcome prediction in patients with advanced ovarian cancer using computed tomography scans and intraoperative findings

    Directory of Open Access Journals (Sweden)

    Ha-Jeong Kim

    2014-09-01

    Conclusion: The combination of omental extension to the stomach or spleen and involvement of inguinal or pelvic lymph nodes in preoperative CT scans is considered predictive of suboptimal cytoreduction. These patients may be more appropriately treated with neoadjuvant chemotherapy followed by surgical cytoreduction.

  6. Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)

    International Nuclear Information System (INIS)

    Sabour, Siamak; Rutten, A.; Schouw, Y. T. van der; Atsma, F.; Grobbee, D. E.; Mali, W. P.; Bartelink, M. E. L.; Bots, M. L.; Prokop, M.

    2007-01-01

    Purpose. To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables.Design. Cross-sectional study with repeated measurements. Materials and methods. The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC).Results. Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements.Conclusion. Inter-scan reproducibility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter

  7. Transient gyriform brightness on non-contrast enhanced computed tomography (CT) brain scan of seven infants

    International Nuclear Information System (INIS)

    Close, P.J.; Carty, H.M.

    1991-01-01

    Spontaneous gyriform brightness seen on CT scan is an unusual finding unless associated with arteriovenous malformations (AVM). There are sporadic case reports in the literature of its occurrence in association with herpex simplex virus encephalitis (HSVE), purulent meningitis, following chemotherapy for leukaemia, in a child with chronic renal failure, and in a child with folic acid deficiency. We present a series of seven cases exhibiting this phenomenon, none of whom have AVMs, who have been scanned at this hospital in the first 2 1/2 years following the installation of a CT scanner. Four of the cases had congenital heart disease requiring corrective surgery or cardiac catheterisation. The other three had probable meningo-encephalitis. In all cases the gyriform brightness followed an ischaemic insult to the child's brain. We hypothesise that this phenomenon is an ischaemic response in the immature brain and that its occurrence is not so rare as the literature may suggest. (orig.)

  8. Ultrasound detection of pneumothorax compared with chest X-ray and computed tomography scan.

    Science.gov (United States)

    Nagarsheth, Khanjan; Kurek, Stanley

    2011-04-01

    Pneumothorax after trauma can be a life threatening injury and its care requires expeditious and accurate diagnosis and possible intervention. We performed a prospective, single blinded study with convenience sampling at a Level I trauma center comparing thoracic ultrasound with chest X-ray and CT scan in the detection of traumatic pneumothorax. Trauma patients that received a thoracic ultrasound, chest X-ray, and chest CT scan were included in the study. The chest X-rays were read by a radiologist who was blinded to the thoracic ultrasound results. Then both were compared with CT scan results. One hundred and twenty-five patients had a thoracic ultrasound performed in the 24-month period. Forty-six patients were excluded from the study due to lack of either a chest X-ray or chest CT scan. Of the remaining 79 patients there were 22 positive pneumothorax found by CT and of those 18 (82%) were found on ultrasound and 7 (32%) were found on chest X-ray. The sensitivity of thoracic ultrasound was found to be 81.8 per cent and the specificity was found to be 100 per cent. The sensitivity of chest X-ray was found to be 31.8 per cent and again the specificity was found to be 100 per cent. The negative predictive value of thoracic ultrasound for pneumothorax was 0.934 and the negative predictive value for chest X-ray for pneumothorax was found to be 0.792. We advocate the use of chest ultrasound for detection of pneumothorax in trauma patients.

  9. A cone-beam computed tomography triple scan procedure to obtain a three-dimensional augmented virtual skull model appropriate for orthognathic surgery planning.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Clercq, C. De; Abeloos, J.V.S.; Lamoral, P.; Lippens, F.R.C.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan

  10. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions

    NARCIS (Netherlands)

    Wiranto, Matthew G.; Engelbrecht, W. Petrie; Nolthenius, Heleen E. Tutein; van der Meer, W. Joerd; Ren, Yijin

    INTRODUCTION: Digital 3-dimensional models are widely used for orthodontic diagnosis. The aim of this study was to assess the validity, reliability, and reproducibility of digital models obtained from the Lava Chairside Oral scanner (3M ESPE, Seefeld, Germany) and cone-beam computed tomography scans

  11. The value of indicated computed tomography scan of the chest and abdomen in addition to the conventional radiologic work-up for blunt trauma patients.

    NARCIS (Netherlands)

    Deunk, J.; Dekker, H.M.; Brink, M.; Vugt, R. van; Edwards, M.J.R.; Vugt, A.B. van

    2007-01-01

    BACKGROUND: Multidetector computed tomography (CT) is more sensitive and specific in detecting traumatic injuries than conventional radiology is. However, still little is known about the diagnostic value and the therapeutic impact of indicated thoraco-abdominal CT scan when it is performed in

  12. Localization of the surgical bed using supine magnetic resonance and computed tomography scan fusion for planification of breast interstitial brachytherapy

    International Nuclear Information System (INIS)

    Jolicoeur, Marjory; Racine, Marie-Lynn; Trop, Isabelle; Hathout, Lara; Nguyen, David; Derashodian, Talar; David, Sandrine

    2011-01-01

    Purpose: To evaluate the feasibility of supine breast magnetic resonance imaging (MR) for definition and localization of the surgical bed (SB) after breast conservative surgery. To assess the inter-observer variability of surgical bed delineation on computed tomography (CT) and supine MR. Materials and methods: Patients candidate for breast brachytherapy and no contra-indications for MR were eligible for this study. Patients were placed in supine position, with the ipsilateral arm above the head in an immobilization device. All patients underwent CT and MR in the same implant/treatment position. Four points were predefined for CT-MRI image fusion. The surgical cavity was drawn on CT then MRI, by three independent observers. Fusion and analysis of CT and MR images were performed using the ECLIPSE treatment planning software. Results: From September 2005 to November 2008, 70 patients were included in this prospective study. For each patient, we were able to acquire axial T1 and T2 images of good quality. Using the predefined fusion points, the median error following the fusion was 2.7 mm. For each observer, volumes obtained on MR were, respectively, 30%, 38% and 40% smaller than those derived from CT images. A highly significant inter-observer variability in the delineation of the SB on CT was demonstrated (p < 0.0001). On the contrary, all three observers agreed on the volume of the SB drawn on MR. Conclusion: Supine breast MRI yields a more precise definition of the SB with a smaller inter-observer variability than CT and may obviate the need for surgical clips. The volume of the SB is smaller with MRI. In our opinion, CT-MRI fusion should be used for SB delineation, in view of partial breast irradiation.

  13. Sternal Healing after Coronary Artery Bypass Grafting Using Bilateral Internal Thoracic Arteries: Assessment by Computed Tomography Scan

    Directory of Open Access Journals (Sweden)

    Yoon Cheol Shin

    2015-02-01

    Full Text Available Background: This study aimed to investigate sternal healing over time and the incidence of poor sternal healing in patients undergoing coronary artery bypass graft (CABG surgery using bilateral internal thoracic arteries. Methods: This study enrolled 197 patients who underwent isolated CABG using skeletonized bilateral internal thoracic arteries (sBITA from 2006 through 2009. Postoperative computed tomography (CT angiography was performed on all patients at monthly intervals for three to six months after surgery. In 108 patients, an additional CT study was performed 24 to 48 months after surgery. The axial CT images were used to score sternal fusion at the manubrium, the upper sternum, and the lower sternum. These scores were added to evaluate overall healing: a score of 0 to 1 reflected poor healing, a score of 2 to 4 was defined as fair healing, and a score of 5 to 6 indicated complete healing. Medical records were also retrospectively reviewed to identify perioperative variables associated with poor early sternal healing. Results: Three to six months after surgery, the average total score of sternal healing was 2.07±1.52 and 68 patients (34.5% showed poor healing. Poor healing was most frequently found in the manubrium, which was scored as zero in 72.6% of patients. In multivariate analysis, the factors associated with poor early healing were shorter post-surgery time, older age, diabetes mellitus, and postoperative renal dysfunction. In later CT images, the average sternal healing score improved to 5.88±0.38 and complete healing was observed in 98.2% of patients. Conclusion: Complete sternal healing takes more than three months after a median sternotomy for CABG using sBITA. Healing is most delayed in the manubrium.

  14. Axial tomography in live cell laser microscopy

    Science.gov (United States)

    Richter, Verena; Bruns, Sarah; Bruns, Thomas; Weber, Petra; Wagner, Michael; Cremer, Christoph; Schneckenburger, Herbert

    2017-09-01

    Single cell microscopy in a three-dimensional (3-D) environment is reported. Cells are grown in an agarose culture gel, located within microcapillaries and observed from different sides after adaptation of an innovative device for sample rotation. Thus, z-stacks can be recorded by confocal microscopy in different directions and used for illustration in 3-D. This gives additional information, since cells or organelles that appear superimposed in one direction, may be well resolved in another one. The method is tested and validated with single cells expressing a membrane or a mitochondrially associated green fluorescent protein, or cells accumulating fluorescent quantum dots. In addition, axial tomography supports measurements of cellular uptake and distribution of the anticancer drug doxorubicin in the nucleus (2 to 6 h after incubation) or the cytoplasm (24 h). This paper discusses that upon cell rotation an enhanced optical resolution in lateral direction compared to axial direction can be utilized to obtain an improved effective 3-D resolution, which represents an important step toward super-resolution microscopy of living cells.

  15. X-ray Compton line scan tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  16. Posterior Urethra Rupture: Contrast-Enhanced Computed Tomography Scan and Urethrocystography Demonstrations

    Directory of Open Access Journals (Sweden)

    Wojciech Marks

    2012-01-01

    Full Text Available In the follow-up study of patients with pelvic fractures, rupture of the posterior urethra is registered in 3–25% of cases (Koraitim et al., 1996. The diagnostic gold standard for the assessment of hemodynamically stable trauma patients is contrast-enhanced CT scan, especially helical CT. Nevertheless, simultaneous suprapubic cystography and ascending urethrograms (the so-called up-and-downogram are the investigation of choice in assessing the site, severity, and length of urethral injuries. (Carlin and Resnick, 1995 This paper discusses the evaluation and diagnosis of urethral injury in multiple-trauma patient.

  17. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  19. Detection of defects in logs using computer assisted tomography (CAT) scanning

    International Nuclear Information System (INIS)

    Tonner, P.D.; Lupton, L.R.

    1985-01-01

    The Chalk River Nuclear Laboratories of AECL have performed a preliminary feasibility study on the applicability of computer assisted tomographic techniques to detect the internal structure of logs. Cross sections of three logs have been obtained using a medical CAT scanner. The results show that knots, rot and growth rings are easily recognized in both dry and wet logs

  20. Quantifying Appropriate PTV Setup Margins: Analysis of Patient Setup Fidelity and Intrafraction Motion Using Post-Treatment Megavoltage Computed Tomography Scans

    International Nuclear Information System (INIS)

    Drabik, Donata M.; MacKenzie, Marc A.; Fallone, Gino B.

    2007-01-01

    Purpose: To present a technique that can be implemented in-house to evaluate the efficacy of immobilization and image-guided setup of patients with different treatment sites on helical tomotherapy. This technique uses an analysis of alignment shifts between kilovoltage computed tomography and post-treatment megavoltage computed tomography images. The determination of the shifts calculated by the helical tomotherapy software for a given site can then be used to define appropriate planning target volume internal margins. Methods and Materials: Twelve patients underwent post-treatment megavoltage computed tomography scans on a helical tomotherapy machine to assess patient setup fidelity and net intrafraction motion. Shifts were studied for the prostate, head and neck, and glioblastoma multiforme. Analysis of these data was performed using automatic and manual registration of the kilovoltage computed tomography and post-megavoltage computed tomography images. Results: The shifts were largest for the prostate, followed by the head and neck, with glioblastoma multiforme having the smallest shifts in general. It appears that it might be more appropriate to use asymmetric planning target volume margins. Each margin value reported is equal to two standard deviations of the average shift in the given direction. Conclusion: This method could be applied using individual patient post-image scanning and combined with adaptive planning to reduce or increase the margins as appropriate

  1. Evaluation of radiation dose in chest scan with enhanced dual-source computed tomography in children with congenital heart disease

    International Nuclear Information System (INIS)

    Hou Zhihui; Lu Bin; Tang Xiang; Han Lei

    2011-01-01

    Objective: To evaluate the radiation dose from enhanced dual-source computed Tomography (DSCT) scan on children with congenital heart disease (CHD). Methods: Seventy children with CHD, age from 1 month to 8 years old, were scanned with enhanced DSCT. Children were divided by age into 5 years old group. The differences among three groups were tested by F test. Then, the SNK test was used to compare the difference between each group. Multiple linear regression analysis was used to test the relationship of dose length product (DLP) with the age, weight, voltage, current, pitch and scan sheet. Results: The average value of DLP was (144.46± 74.07) mGy·cm for all the 70 cases, and that of effective does (ED) was (4.68±2.34) mSv. There were significant differences of DLP among the 3 groups [ 5 years (208.00±73.87) mGy · cm, F=8.26, P=0.0009]. The SNK test showed statistical differences of DLP between 5 years old group (q=5.21, 6.52, P=0.009, 0.004). The difference of DLP between 1-5 years old group and > 5 years old group did not reach significant (q=0.28, P=0.48). The differences of ED was not statistically significant among the three groups [ 5 years (3.74±1.33) mSv, F=0.54, P=0.59]. DLP was positively correlated with age (4.3 years, r=0.54186, P=0.0008), weight (12.1 kg, r=0.56371, P=0.0004), voltage [(95.48±6.99) kV, r=0.63269, P<0.01], current [(138.55±40.67) mA, r=0.79608, P< 0.0001] and scan sheet (236.10±46.51, r=0.72192, P<0.01). DLP was negative correlated with pitch (0.48±0.03, r=-0.46693, P=0.0047). Conclusion: Higher DLP was observed in children over 1 year old under enhanced DSCT scan, but ED was not statistically significant among the three groups due to the higher K value in the children under 1 year old. (authors)

  2. The history and principles of optical computed tomography for scanning 3-D radiation dosimeters: 2008 update

    Energy Technology Data Exchange (ETDEWEB)

    Doran, Simon J [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Sutton, Surrey (United Kingdom); Department of Physics, University of Surrey, Surrey (United Kingdom)], E-mail: Simon.Doran@icr.ac.uk

    2009-05-01

    The current status of optical CT for 3-D radiation dosimetry is reviewed. The technique is first placed in its historical context, pointing out the relationship with other methods of optical imaging and showing how optical-CT has emerged independently in several different fields and under different names. The theoretical background of the method is described briefly and this provides the foundation for an explanation of the different types of scanner. The relative advantages and disadvantages of instruments based on scanned lasers and pixelated (area) detectors are presented. The latest generation of 'fast laser scanners' is described and the review is concluded with a discussion of the different radiation-sensitive materials used as samples in optical CT.

  3. Scanning protocol of dual-source computed tomography for aortic dissection

    International Nuclear Information System (INIS)

    Zhai Mingchun; Wang Yongmei

    2013-01-01

    Objective: To find a dual-source CT scanning protocol which can obtain high image quality with low radiation dose for diagnosis of aortic dissection. Methods: Total 120 patients with suspected aortic dissection were randomly and equally assigned into three groups. Patients in Croup A were performed CTA exam with prospectively electrocardiogram- gated high pitch spiral mode (FLASH). Patients in Croup B were performed CTA exam with retrospective electrocardiogram- gated spiral mode. Patients in Croup C were performed CTA exam with conventional mode which no electrocardiogram-gated. The image quality, radiation dose, advantages and disadvantages among the three scan protocol were analyzed. Results: For image quality, seventeen, twenty two and one patients in group A were granted to grade 1, 2, 3 respectively, and none was in grade 4; thirty three and seven patients in group B were granted to grade 1, 2, respectively, and none was in grade 3 and 4; fourteen and twenty six patients in group C were granted to grade 3, 4, respectively, and none was in grade 1 and 2. There was no significant difference between group A and B in image quality. Compared with the image quality, Group A and B were significantly higher than Group C. Mean effective radiation dose of Croup A, B and C were 7.7±0.4 mSv, 33.11±3.38 mSv, and 7.6±0.68 mSv, respectively. Group B was significantly higher than Groups A and C (P<0.05, P<0.05, respectively), and there was no significant difference between Group A and C (P=0.826). Conclusions: Prospectively electrocardiogram-gated high pitch spiral mode can be the first line protocol for evaluation of aortic dissection. It can achieve high image quality with low radiation dose. Conventional mode with no electrocardiogram-gated can be selectively used for Stanford B aortic dissection. (authors)

  4. Multidetector computed tomography for the assessment of adnexal Mass: Is unenhenced CT scan necessary?

    International Nuclear Information System (INIS)

    Jung, Sung Il; Park, Hee Sun; Kim, Young Jun; Jeon, Hae Jeong

    2014-01-01

    To compare the diagnostic performance and radiation dose between contrast-enhanced CT (ECT) alone, and combined unenhanced and contrast-enhanced CT (UE + ECT) for the assessment of adnexal mass. This retrospective study was approved by the Institutional Review Board. A total of 146 consecutive patients (mean age, 41.1 years) who underwent preoperative unenhanced and contrast-enhanced multidetector CT of the pelvis and had adnexal masses found at surgery were included. Two readers independently evaluated the likelihood of adnexal malignancy on a 5-point scale on two different imaging datasets (ECT alone and UE + ECT). The area under the receiver operating characteristic curve (AUC) was used to evaluate diagnostic performance. Radiation dose to patients was calculated by the volume CT dose index (CTDIvol) and the dose length products (DLP) on each dataset. Of the total 178 adnexal masses, 133 masses were benign and 45 masses were malignant. For both readers, there is no significant difference of AUC values between ECT alone and UE + ECT for the detection of adnexal malignancy (reader 1, 0.93 vs. 0.95; reader 2, 0.92 vs. 0.91) (p > 0.05). The mean CTDIvol (12.6 ± 2.2 mGy) and DLP (641.2 ± 137.2 mGy) of ECT alone was significantly lower than the mean CTDIvol (21.5 ± 2.7 mGy) and DLP (923.6 ± 158.8 mGy) of UE + ECT (p < 0.0001). The use of unenhanced CT scan in addition to contrast-enhanced CT scan does not improve the detection of adnexal malignancy, but increases radiation exposure.

  5. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  6. Radiation Dose to the Lens of the Eye from Computed Tomography Scans of the Head

    Science.gov (United States)

    Januzis, Natalie Ann

    While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient's medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods. The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data. The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult. First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion

  7. Is direct radiologist supervision of abdominal computed tomography (CT) scans necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Goh, V. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood (United Kingdom); Halligan, S. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom)]. E-mail: s.halligan@imperial.ac.uk; Anderson, J.M. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Hugill, J. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Leonard, A. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom)

    2005-07-01

    AIM: To determine the effect of direct radiological supervision of patients attending for abdominal CT by assessing the frequency of protocol alteration subsequent to radiologist review of the images obtained. MATERIALS AND METHODS: A prospective questionnaire-based observational study was performed of 187 consecutive patients undergoing abdominal CT. The CT protocol was determined by a radiologist in advance, with reference to the request form. Any subsequent change in the prescribed study that was contingent on radiologist review of the images obtained was documented on the questionnaire. Comparison was made with a second (control) group of 100 patients undergoing cranial CT. RESULTS: A protocol change was undertaken following radiologist review of the CT images of 17 (9%) of the group undergoing abdominal CT, compared with 14 (14%) of the group undergoing cranial CT. In the abdominal CT group, further scanning was performed for lesion characterization, to guide a subsequent interventional procedure, because of inadequate anatomical coverage or to evaluate an unexpected lung tumour. There was no significant difference in proportions between the two groups (p=0.23). CONCLUSION: When abdominal and cranial CT studies were compared, there was no significant difference in the proportion of studies requiring a change in the prescribed protocol following radiologist review of the images obtained. There was no evidence to suggest that abdominal CT was any less suited to protocol.

  8. The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method.

    Science.gov (United States)

    Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian

    2016-05-01

    Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET/CT) Findings in an Unusual Case of Multiple Myeloma Presenting with a Large Extra-Axial Intracranial Mass.

    Science.gov (United States)

    Ayaz, Sevin; Ayaz, Ümit Yaşar

    2016-01-01

    We aimed to present unusual cranial FDG PET/CT findings of a 56-year-old female with multiple myeloma (MM). Plain CT images revealed a lytic lesion in the right parietal bone, filled with an oval-shaped, large, extra-axial, extradural, intracranial mass which measured 75×75×40 mm and had smooth borders. The right parietal lobe was compressed by the mass. The maximum standardized uptake value (SUV max ) of the mass lesion was 8.94 on FDG PET/CT images. Multiple lytic lesions with an increased uptake were also detected in other calvarial bones, in several vertebras and in the proximal left femur. After seven months, a control FDG PET/CT following radiotherapy and chemotherapy revealed almost complete regression of the right parietal extra-axial mass lesion. The number, size and metabolism of lytic lesions in other bones also decreased. FDG PET/CT was useful for an initial evaluation of MM lesions and was effective in monitoring the response of these lesions to therapy.

  10. Diagnostic accuracy of full-body linear X-ray scanning in multiple trauma patients in comparison to computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Joeres, A.P.W.; Heverhagen, J.T.; Bonel, H. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Exadaktylos, A. [Inselspital - University Hospital Bern (Switzerland). Dept. of Emergency Medicine; Klink, T. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Wuerzburg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology

    2016-02-15

    The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. The overall sensitivity of LS was 49.2%, the specificity was 93.3%, the positive predictive value was 91%, and the negative predictive value was 57.5%. The overall sensitivity for vertebral fractures was 16.7%, and the specificity was 100%. The sensitivity was 48.7% and the specificity 98.2% for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS.40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT.

  11. How do trees grow? Response from the graphical and quantitative analyses of computed tomography scanning data collected on stem sections.

    Science.gov (United States)

    Dutilleul, Pierre; Han, Li Wen; Beaulieu, Jean

    2014-06-01

    Tree growth, as measured via the width of annual rings, is used for environmental impact assessment and climate back-forecasting. This fascinating natural process has been studied at various scales in the stem (from cell and fiber within a growth ring, to ring and entire stem) in one, two, and three dimensions. A new approach is presented to study tree growth in 3D from stem sections, at a scale sufficiently small to allow the delineation of reliable limits for annual rings and large enough to capture directional variation in growth rates. The technology applied is computed tomography scanning, which provides - for one stem section - millions of data (indirect measures of wood density) that can be mapped, together with a companion measure of dispersion and growth ring limits in filigree. Graphical and quantitative analyses are reported for white spruce trees with circular vs non-circular growth. Implications for dendroclimatological research are discussed. Copyright © 2014 Académie des sciences. Published by Elsevier SAS. All rights reserved.

  12. Non-Contrast Computed Tomography Scan Based Parameters of Ureteric Stones Affecting the Outcome of Extracorporeal Shock Wave Lithotripsy

    Science.gov (United States)

    Ayaz Khan, Mohammad; Waqas Iqbal, Muhammad; Akbar, Mian Khalid; Saqib, Imad-ud-din; Akhter, Saeed

    2017-01-01

    Objective  To compare the non-contrast computed tomography (NCCT) scan-based parameters of ureteric stones affecting the outcome of extracorporeal shock wave lithotripsy (ESWL). Materials and methods We retrospectively evaluated the pre-procedure NCCT of 74 patients who had ESWL for solitary ureteric calculi of 5-20 mm in diameter. We assessed the age, sex, basal metabolic index (BMI), laterality, location, presence of double 'J' (DJ) stent, skin to stone distance (SSD), stone maximum diameter, Hounsfield unit (HU), Hounsfield density (HD), area, and volume. All those who had no stone on follow-up imaging within 30 days were declared successful while those who had residual stone were declared failures. Results The overall success rate was 78% (58/74). Sixty (81.1%) patients were male. The success of ESWL was correlated with lower SSD, Hounsfield units (HU) and Hounsfield density (HD). However, in multivariate analysis, SSD, Hounsfield unit, and stone area showed correlation with success of procedure but Hounsfield density failed to show correlation. The success rate in patients with stone HU 1000 were 93.9%, 69%, and 58.3%, respectively. Patients with lower BMI (30 kg/m2) and higher HD (>76 HU/mm). Conclusion BMI, SSD, stone Hounsfield units and Hounsfield unit density were strong predictors of outcome of ESWL for ureteric stone. PMID:28589076

  13. Prevalence and diagnostic performance of computed tomography angiography spot sign for intracerebral hematoma expansion depend on scan timing

    Energy Technology Data Exchange (ETDEWEB)

    Tsukabe, Akio; Watanabe, Yoshiyuki; Tanaka, Hisashi; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Yoshiya, Kazuhisa; Shimazu, Takeshi [Osaka University Graduate School of Medicine, Department of Traumatology and Acute Critical Medicine, Suita, Osaka (Japan)

    2014-12-15

    The computed tomography angiography (CTA) spot sign correlates with intracerebral hemorrhage (ICH) expansion; however, various diagnostic performances for hematoma expansion, especially in sensitivity, have been reported. We aimed to assess the impact of scan timing of CTA on the diagnostic performance of the CTA spot sign for ICH expansion in two different arterial phases within patients. Eighty-three consecutive patients with primary ICH who received two sequential CTAs were recruited. Two neuroradiologists reviewed CTAs for CTA spot signs, while one reviewed initial and follow-up non-contrast CT for measuring ICH volume. The time interval between two phases was then calculated, and the diagnostic performance of CTA spot sign in each phase was evaluated. CTA spot signs were observed in 20/83 (24.1 %) patients in the early phase and 44/83 (53.0 %) patients in the late phase. The mean time interval between the two phases was 12.7 s. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for hematoma progression of CTA spot sign were 48.1, 87.5, 65.0, 77.8, and 74.7 %, respectively, in early phase and 92.6, 66.1, 56.8, 94.9, and 74.7 %, respectively, in late phase. The CTA spot sign was significantly associated with ICH expansion in early (P < 0.001) and late (P < 0.00001) phases (Pearson's chi-square test). A mere 10-s difference in scan timing could make a difference on prevalence and diagnostic performance of the CTA spot sign, suggesting a need for the standardization of the CTA protocol to generalize the approach for effective clinical application. (orig.)

  14. Detection of distant metastases in patients with locally advanced breast cancer: role of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography and conventional imaging with computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Andrade, Wesley Pereira; Cunha, Rodrigo Rodrigues da; Conrado, Jorge Luis Fonseca de Acioli; Lima, Eduardo Nobrega Pereira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens, E-mail: rodrigo.rcunha@hotmail.com [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Hospital Beneficincia Portuguesa de Sao Paulo, Sao Paulo, SP (Brazil)

    2017-07-15

    Objective: To evaluate positron emission tomography/computed tomography (PET/CT) and conventional imaging tests for the detection of distant metastases in patients with locally advanced breast cancer. Materials and Methods: We included 81 patients with breast cancer who had undergone {sup 18}-fluorodeoxyglucose (FDG) PET/CT before treatment. Conventional imaging included the following: bone scintigraphy; chest X-ray (in 14.5%) or CT (in 85.5%); and abdominal ultrasound (in 10.8%), CT (in 87.8%), or magnetic resonance imaging (in 1.4%). Histopathology and clinical/imaging follow-up served as reference. Results: Distant metastases were observed in nine patients (11.1%). On patient-based analysis, conventional imaging identified distant metastases in all 9 patients. In one patient, the initial {sup 18}F-FDG PET/CT failed to demonstrate bone metastases that was evident on bone scintigraphy. In two patients, the CT scan failed to show extra-axillary lymph node metastases that were identified on {sup 18}F-FDG PET/CT. There was no significant difference between {sup 18}F-FDG PET/CT and conventional imaging in terms of their sensitivity for the detection of distant metastases in patients with locally advanced breast cancer. Conclusion: This study showed that {sup 18}F-FDG PET/CT and conventional imaging with CT scans had similar sensitivity for the diagnosis of distant metastases in patients with locally advanced breast cancer. {sup 18}F-FDG PET/CT can add information about extra-axillary lymph node involvements. (author)

  15. Robust semi-automatic segmentation of pulmonary subsolid nodules in chest computed tomography scans

    International Nuclear Information System (INIS)

    Lassen, B C; Kuhnigk, J-M; Van Ginneken, B; Van Rikxoort, E M; Jacobs, C

    2015-01-01

    The malignancy of lung nodules is most often detected by analyzing changes of the nodule diameter in follow-up scans. A recent study showed that comparing the volume or the mass of a nodule over time is much more significant than comparing the diameter. Since the survival rate is higher when the disease is still in an early stage it is important to detect the growth rate as soon as possible. However manual segmentation of a volume is time-consuming. Whereas there are several well evaluated methods for the segmentation of solid nodules, less work is done on subsolid nodules which actually show a higher malignancy rate than solid nodules. In this work we present a fast, semi-automatic method for segmentation of subsolid nodules. As minimal user interaction the method expects a user-drawn stroke on the largest diameter of the nodule. First, a threshold-based region growing is performed based on intensity analysis of the nodule region and surrounding parenchyma. In the next step the chest wall is removed by a combination of a connected component analyses and convex hull calculation. Finally, attached vessels are detached by morphological operations. The method was evaluated on all nodules of the publicly available LIDC/IDRI database that were manually segmented and rated as non-solid or part-solid by four radiologists (Dataset 1) and three radiologists (Dataset 2). For these 59 nodules the Jaccard index for the agreement of the proposed method with the manual reference segmentations was 0.52/0.50 (Dataset 1/Dataset 2) compared to an inter-observer agreement of the manual segmentations of 0.54/0.58 (Dataset 1/Dataset 2). Furthermore, the inter-observer agreement using the proposed method (i.e. different input strokes) was analyzed and gave a Jaccard index of 0.74/0.74 (Dataset 1/Dataset 2). The presented method provides satisfactory segmentation results with minimal observer effort in minimal time and can reduce the inter-observer variability for segmentation of

  16. Robust semi-automatic segmentation of pulmonary subsolid nodules in chest computed tomography scans

    Science.gov (United States)

    Lassen, B. C.; Jacobs, C.; Kuhnigk, J.-M.; van Ginneken, B.; van Rikxoort, E. M.

    2015-02-01

    The malignancy of lung nodules is most often detected by analyzing changes of the nodule diameter in follow-up scans. A recent study showed that comparing the volume or the mass of a nodule over time is much more significant than comparing the diameter. Since the survival rate is higher when the disease is still in an early stage it is important to detect the growth rate as soon as possible. However manual segmentation of a volume is time-consuming. Whereas there are several well evaluated methods for the segmentation of solid nodules, less work is done on subsolid nodules which actually show a higher malignancy rate than solid nodules. In this work we present a fast, semi-automatic method for segmentation of subsolid nodules. As minimal user interaction the method expects a user-drawn stroke on the largest diameter of the nodule. First, a threshold-based region growing is performed based on intensity analysis of the nodule region and surrounding parenchyma. In the next step the chest wall is removed by a combination of a connected component analyses and convex hull calculation. Finally, attached vessels are detached by morphological operations. The method was evaluated on all nodules of the publicly available LIDC/IDRI database that were manually segmented and rated as non-solid or part-solid by four radiologists (Dataset 1) and three radiologists (Dataset 2). For these 59 nodules the Jaccard index for the agreement of the proposed method with the manual reference segmentations was 0.52/0.50 (Dataset 1/Dataset 2) compared to an inter-observer agreement of the manual segmentations of 0.54/0.58 (Dataset 1/Dataset 2). Furthermore, the inter-observer agreement using the proposed method (i.e. different input strokes) was analyzed and gave a Jaccard index of 0.74/0.74 (Dataset 1/Dataset 2). The presented method provides satisfactory segmentation results with minimal observer effort in minimal time and can reduce the inter-observer variability for segmentation of

  17. Cervical lymph node hyperplasia on [18F]-fluorodeoxyglucose positron emission tomography/computed tomography scan after treatment of children and adolescents with malignant lymphoma

    International Nuclear Information System (INIS)

    Hu, Ying-Ying; Zhang, Xu; Long, Wen; Lin, Xiao-Ping; Zhang, Ya-Rui; Li, Yuan-Hua; Xiao, Zi-Zheng; Zheng, Rong-Liang; Liang, Pei-Yan; Fan, Wei

    2015-01-01

    Highlights: • Cervical lymph node hyperplasia is a benign processes. • Lymph node hyperplasia found in treated children and adolescents with lymphoma. • We define imaging manifestations of cervical lymph node hyperplasia in PET/CT. • Awareness of lymph node hyperplasia avoid invasive procedures and over-treatment. - Abstract: Purpose: To define imaging manifestations and clinical prognosis of cervical lymph node hyperplasia using [ 18 F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning after treatment of children and adolescents with malignant lymphoma. Methods: Children and adolescent patients with malignant lymphoma who had high FDG uptake in their cervical lymph nodes via PET/CT after treatment, which was not due to tumor recurrence or residue, were retrospectively analyzed. Results: Twenty-seven patients with a median age of 12 years were included; 11 had Hodgkin's disease and 16 had non-Hodgkin's lymphoma. The time from PET/CT scan to completion of therapy was 1–36 months, 85.2% (23/27) of which took place within 12 months. Three patients had confirmed lymph node follicular hyperplasia by biopsy, while all 27 patients achieved disease-free survival during the follow-up period. The maximum standardized uptake values (SUV max ) of cervical lymph nodes were 2.2–16.2 and the maximum short axis ranged from 0.3 to 1.2 cm. Cervical lymph node hyperplasia was noted in neck levels I–V, and neck level II bilaterally had the highest incidence (100%). Bilateral cervical lymph node hyperplasia was symmetrical in terms of both the SUV max and affected locations. Thymic hyperplasia and nasopharyngeal lymphoid hyperplasia were both observed in 24 patients (88.9%). There was no relationship in terms of the SUV max between cervical lymph nodes and thymic tissue, cervical nodes or nasopharyngeal lymphoid tissue. Conclusion: Cervical lymph node hyperplasia with high FDG uptake on PET/CT scans found after treating

  18. Cervical lymph node hyperplasia on [{sup 18}F]-fluorodeoxyglucose positron emission tomography/computed tomography scan after treatment of children and adolescents with malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Ying-Ying, E-mail: huyy@sysucc.org.cn; Zhang, Xu, E-mail: zhangxu2@sysucc.org.cn; Long, Wen, E-mail: longwen2@sysucc.org.cn; Lin, Xiao-Ping, E-mail: linxp@sysucc.org.cn; Zhang, Ya-Rui, E-mail: zhangyr@sysucc.org.cn; Li, Yuan-Hua, E-mail: liyh@sysucc.org.cn; Xiao, Zi-Zheng, E-mail: xiaozzh@sysucc.org.cn; Zheng, Rong-Liang, E-mail: zhengrl@sysucc.org.cn; Liang, Pei-Yan, E-mail: liangpy@sysucc.org.cn; Fan, Wei, E-mail: fanwei@sysucc.org.cn

    2015-07-15

    Highlights: • Cervical lymph node hyperplasia is a benign processes. • Lymph node hyperplasia found in treated children and adolescents with lymphoma. • We define imaging manifestations of cervical lymph node hyperplasia in PET/CT. • Awareness of lymph node hyperplasia avoid invasive procedures and over-treatment. - Abstract: Purpose: To define imaging manifestations and clinical prognosis of cervical lymph node hyperplasia using [{sup 18}F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning after treatment of children and adolescents with malignant lymphoma. Methods: Children and adolescent patients with malignant lymphoma who had high FDG uptake in their cervical lymph nodes via PET/CT after treatment, which was not due to tumor recurrence or residue, were retrospectively analyzed. Results: Twenty-seven patients with a median age of 12 years were included; 11 had Hodgkin's disease and 16 had non-Hodgkin's lymphoma. The time from PET/CT scan to completion of therapy was 1–36 months, 85.2% (23/27) of which took place within 12 months. Three patients had confirmed lymph node follicular hyperplasia by biopsy, while all 27 patients achieved disease-free survival during the follow-up period. The maximum standardized uptake values (SUV{sub max}) of cervical lymph nodes were 2.2–16.2 and the maximum short axis ranged from 0.3 to 1.2 cm. Cervical lymph node hyperplasia was noted in neck levels I–V, and neck level II bilaterally had the highest incidence (100%). Bilateral cervical lymph node hyperplasia was symmetrical in terms of both the SUV{sub max} and affected locations. Thymic hyperplasia and nasopharyngeal lymphoid hyperplasia were both observed in 24 patients (88.9%). There was no relationship in terms of the SUV{sub max} between cervical lymph nodes and thymic tissue, cervical nodes or nasopharyngeal lymphoid tissue. Conclusion: Cervical lymph node hyperplasia with high FDG uptake on PET/CT scans found

  19. 18-F flourodeoxy glucose positron emission tomography-computed tomography imaging: A viable alternative to three phase bone scan in evaluating diabetic foot complications?

    International Nuclear Information System (INIS)

    Shagos, G. S.; Shanmugasundaram, Palaniswamy; Varma, Ajith Kumar; Padma, Subramanyam; Sarma, Manjit

    2015-01-01

    This paper is based on the initial findings from a prospective ongoing study to evaluate the efficacy of flourodeoxy glucose positron emission tomography-computed tomography (FDG-PET CT) in diabetic foot evaluation. The aim was to compare the diagnostic accuracies of three phase bone scan (TPBS) and FDG PET-CT (FDG-PET) in diabetic foot evaluation. Seventy-nine patients with complicated diabetic foot (osteomyelitis/cellulitis, Charcot's neuropathy) were prospectively investigated. TPBS (15 mci methylene di phosphonate [MDP] intravenous [IV]), followed by FDG-PET (5 mci IV) within 5 days were performed in all patients. Based on referral indication, patients grouped into Group I, n = 36, (?osteomyelitis/cellulitis) and Group II, n = 43 (?Charcot's neuropathy). Interpretation was based on intensity, extent, pattern of MDP and FDG uptake (standardized uptake value) along with CT correlation. Findings were compared with final diagnostic outcome based on bone/soft tissue culture in Group I and clinical, radiological or scintigraphic followup in Group II. Results: Group I: For diagnosing osteomyelitis, TP: TN: FP: FN were 14:5:2:2 by FDG PET and 13:02:05:03 by TPBS respectively. Sensitivity, specificity, positive predictive value and negative predictive value (NPV) of FDG-PET were 87.5%, 71%, 87.5% and 71% and 81.25%, 28.5%, 72% and 40% for TPBS, respectively. Group II: charcot's: cellulitis: Normal were 22:14:7 by FDG PET and 32:5:6 by TPBS, respectively. Flourodeoxy glucose PET-CT has a higher specificity and NPV than TPBS in diagnosing pedal osteomyelitis. TPBS, being highly sensitive is more useful than FDG-PET in detecting Charcot's neuropathy

  20. Computed Tomography Scanning Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION:Advances research in the areas of marine geosciences, geotechnical, civil, and chemical engineering, physics, and ocean acoustics by using high-resolution,...

  1. Quantification of Mediastinal and Hilar Lymph Node Movement Using Four-Dimensional Computed Tomography Scan: Implications for Radiation Treatment Planning

    International Nuclear Information System (INIS)

    Sher, David J.; Wolfgang, John A.; Niemierko, Andrzej; Choi, Noah C.

    2007-01-01

    Purpose: To quantitatively describe mediastinal and hilar lymph node movement in patients with lymph node-positive lung cancer. Methods and Materials: Twenty-four patients with lung cancer who underwent four-dimensional computed tomography scanning at Massachusetts General Hospital were included in the study. The maximum extent of superior motion of the superior border was measured, as well as the maximum inferior movement of the inferior border. The average of these two values is defined as the peak-to-peak movement. This process was repeated for mediolateral (ML) and anterior-posterior (AP) movement. Linear regression was used to determine lymph node characteristics associated with peak-to-peak movement. Various uniform expansions were investigated to determine the expansion margins necessary to ensure complete internal target volume (ITV) coverage. Results: The mean peak-to-peak displacements of paratracheal lymph nodes were 4 mm (craniocaudal [CC]), 2 mm (ML), and 2 mm (AP). For subcarinal lymph nodes, the mean peak-to-peak movements were 6 mm (CC), 4 mm (ML), and 2 mm (AP). The mean peak-to-peak displacements of hilar lymph nodes were 7 mm (CC), 1 mm (ML), and 4 mm (AP). On multivariate analysis, lymph node station and lymph node size were significantly related to peak-to-peak movement. Expansions of 8 mm for paratracheal nodes and 13 mm for subcarinal and hilar nodes would have been necessary to cover the ITV of 95% of these nodal masses. Conclusions: Subcarinal and hilar lymph nodes may move substantially throughout the respiratory cycle. In the absence of patient-specific information on nodal motion, expansions of at least 8 mm, 13 mm, and 13 mm should be considered to cover the ITV of paratracheal, subcarinal, and hilar lymph nodes, respectively

  2. Incidence of lumbar spondylolysis in the general population in Japan based on multidetector computed tomography scans from two thousand subjects.

    Science.gov (United States)

    Sakai, Toshinori; Sairyo, Koichi; Takao, Shoichiro; Nishitani, Hiromu; Yasui, Natsuo

    2009-10-01

    Epidemiological analysis using CTs. To investigate the true incidence of lumbar spondylolysis in the general population in Japan. Although there have been several reports on the incidence of lumbar spondylolysis, they had some weakness. One of them concerns the subjects investigated, because the incidence of lumbar spondylolysis varies considerably, and some patients are asymptomatic. In addition, most of the past studies used plain radiograph films or skeletal investigation. Therefore, the past reported incidence may not correspond to that of the general population. We reviewed the computed tomography (CT) scans of 2000 subjects (age: 20-92 years) who had undergone abdominal and pelvic CT on a single multidetector CT scanner for reasons unrelated to low back pain. We reviewed them for spondylolysis, spondylolytic spondylolisthesis, and spina bifida occulta (SBO) in the lumbosacral region. The grade (I-IV) of spondylolisthesis was measured using midsagittal reconstructions. Lumbar spondylolysis was found in 117 subjects (5.9%). Their male-female ratio was 2:1. Multiple-level spondylolysis was found in 5 subjects (0.3%). Among these 117 subjects, there were 124 vertebrae with spondylolysis. Of them, 112 (90.3%) corresponded to L5, and 26 (21.0%) had unilateral spondylolysis.SBO was found in 154 subjects. Of them, 25 had spondylolysis (16.2%), whereas, in 1846 subjects without SBO, 92 had spondylolysis (5.0%). The incidence of spondylolysis among the patients with SBO was significantly higher than that in subjects without SBO (Odd ratio was 3.7-fold).Of 124 vertebrae with spondylolysis, 75 (60.5%) showed low-grade (Meyerding grade I or II) spondylolisthesis, and no subject presented high-grade spondylolisthesis. Spondylolisthesis was found in 74.5% of the subjects with bilateral spondylolysis, and in 7.7% of those with unilateral spondylolysis. The incidence of lumbar spondylolysis in the Japanese general population was 5.9% (males: 7.9%, females: 3.9%).

  3. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  4. Crown traits of coniferous trees and their relation to shade tolerance can differ with leaf type: a biophysical demonstration using computed tomography scanning data

    OpenAIRE

    Dutilleul, Pierre; Han, Liwen; Valladares, Fernando; Messier, Christian

    2015-01-01

    Plant light interception and shade tolerance are intrinsically related in that they involve structural, morphological and physiological adaptations to manage light capture for photosynthetic utilization, in order to sustain survival, development and reproduction. At the scale of small-size trees, crown traits related to structural geometry of branching pattern and space occupancy through phyllotaxis can be accurately evaluated in 3D, using computed tomography (CT) scanning data. We demonstrat...

  5. Crown traits of coniferous trees and their relation to shade tolerance can differ with leaf type: A biophysical demonstration using computed tomography scanning data

    OpenAIRE

    Pierre eDutilleul; Liwen eHan; Fernando eValladeres; Christian eMessier; Christian eMessier

    2015-01-01

    Plant light interception and shade tolerance are intrinsically related in that they involve structural, morphological and physiological adaptations to manage light capture for photosynthetic utilization, in order to sustain survival, development and reproduction. At the scale of small-size trees, crown traits related to structural geometry of branching pattern and space occupancy through phyllotaxis can be accurately evaluated in 3D, using computed tomography (CT) scanning data. We demonstrat...

  6. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  7. Correlação entre hipótese diagnóstica e laudo de tomografia axial computadorizada craniana Correlation between diagnostic hypothesis and result of cranial computed axial tomography

    Directory of Open Access Journals (Sweden)

    Edison Matos Nóvak

    2001-09-01

    Full Text Available Para avaliar a utilização da tomografia axial computadorizada craniana (TC em nosso meio, analisamos as solicitações de 367 exames consecutivos no período compreendido entre 07/1995 e 07/1996. Houve ampla variação da faixa etária, com média de 31,7 ± 22,9 anos. As especialidades que mais solicitaram o exame foram: Neurologia (36,2%, Pronto Atendimento (17,4%, Neuropediatria (16,9% e Clínica Médica (5,9%. As indicações mais frequentes para o exame foram: convulsão (30%, cefaléia (26,2%, déficit motor (20,2% e redução do nível de consciência (16,9%. As "hipóteses" aventadas com maior frequência foram: afastar lesão estrutural (9,0%, acidente vascular não discriminado (8,2% e neurocisticercose (8,2%. O laudo da TC foi normal em 50,4% dos exames. Os laudos anormais mais frequentes foram: hidrocefalia (5,4%, acidente vascular isquêmico (5,4% e neoplasia (3,5%. As maiores taxas de achados normais foram encontradas nas "hipóteses" de cefaléia (94,4%, convulsão (71,4% e afastar lesão estrutural (66,7%. Os maiores índices de acerto entre hipótese e laudo foram encontrados nas situações de "afastar lesões estruturais" (66,7%, hidrocefalia (50%, acidente vascular cerebral isquêmico (50% e hematoma (50%. Concluimos que a utilização de um recurso auxiliar de diagnóstico como a TC cumpre melhor ainda a sua função se o requisitante do exame preencher com clareza e detalhamento o pedido do exame.The use of computed axial tomography (CT in the investigation of neurologic disorders is attractive for his disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 ± 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36

  8. Computerized axial tomography in the detection of brain damage

    International Nuclear Information System (INIS)

    Cala, L.A.; Mastaglia, F.L.

    1980-01-01

    The cranial computerized axial tomography (CAT) findings in groups of patients with epilepsy, migraine, hypertension, and other general medical disorders have been reviewed to assess the frequency and patterns of focal and diffuse brain damage. In addition to demonstrating focal lesions in a proportion of patients with seizures and in patients presenting with a stroke, the CAT scan showed a premature degree of cerebral atrophy in an appreciable proportion of patients with long-standing epilepsy, hypertension and diabetes, and in some patients with migraine, valvular and ischaemic heart disease, chronic obstructive airways disease, and chronic renal failure. The value of CAT as a means of screening for brain damage in groups of individuals at risk is discussed

  9. Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Sennst, Dirk-Alexander; Maxlmoser, Wolfgang; Kalender, Willi A.

    2002-01-01

    Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 deg. MCD and 180 deg. MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorithms provided by the CT manufacturers, high image quality can be achieved. These algorithms require information about the cardiac motion, i.e., typically the simultaneously recorded electrocardiogram (ECG), to synchronize the reconstruction with the cardiac motion. Neither data acquired without ECG information (standard patients) nor acquisitions with corrupted ECG information can be handled adequately. We developed a method to extract the appropriate information about cardiac motion directly from the measured raw data (projection data). The so-called kymogram function is a measure of the cardiac motion as a function of time t or as a function of the projection angle α. In contrast to the ECG which is a global measure of the heart's electric excitation, the kymogram is a local measure of the heart motion at the z-position z(α) at projection angle α. The patient's local heart rate as well as the necessary synchronization information to be used with phase-correlated algorithms can be extracted from the kymogram by using a series of signal processing steps. The kymogram information is shown to be adequate to substitute the ECG information. Computer simulations with simulated ECG and patient measurements with simultaneously acquired ECG were carried out for a multislice scanner providing M=4 slices to evaluate these new approaches. Both the ECG function and the kymogram function were used for reconstruction. Both were highly correlated regarding the periodicity information used for reconstruction. In 21 out of 25 consecutive cases the kymogram approach was equivalent to the ECG-correlated reconstruction; only minor differences in image quality between both

  10. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Fairbairn, I.A.

    1984-01-01

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  11. Analyzing Dental Implant Sites From Cone Beam Computed Tomography Scans on a Tablet Computer: A Comparative Study Between iPad and 3 Display Systems.

    Science.gov (United States)

    Carrasco, Alejandro; Jalali, Elnaz; Dhingra, Ajay; Lurie, Alan; Yadav, Sumit; Tadinada, Aditya

    2017-06-01

    The aim of this study was to compare a medical-grade PACS (picture archiving and communication system) monitor, a consumer-grade monitor, a laptop computer, and a tablet computer for linear measurements of height and width for specific implant sites in the posterior maxilla and mandible, along with visualization of the associated anatomical structures. Cone beam computed tomography (CBCT) scans were evaluated. The images were reviewed using PACS-LCD monitor, consumer-grade LCD monitor using CB-Works software, a 13″ MacBook Pro, and an iPad 4 using OsiriX DICOM reader software. The operators had to identify anatomical structures in each display using a 2-point scale. User experience between PACS and iPad was also evaluated by means of a questionnaire. The measurements were very similar for each device. P-values were all greater than 0.05, indicating no significant difference between the monitors for each measurement. The intraoperator reliability was very high. The user experience was similar in each category with the most significant difference regarding the portability where the PACS display received the lowest score and the iPad received the highest score. The iPad with retina display was comparable with the medical-grade monitor, producing similar measurements and image visualization, and thus providing an inexpensive, portable, and reliable screen to analyze CBCT images in the operating room during the implant surgery.

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  14. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening......CT seems superior to US concerning sensitivity, and is able to detect aneurysmal lesions not detectable with US. Finally, the prevalence of AAA in Denmark seems to remain relatively high, in this small pilot study group....

  15. How to interpret an unenhanced CT Brain scan. Part 1: Basic principles of Computed Tomography and relevant neuroanatomy

    Directory of Open Access Journals (Sweden)

    Thomas Osborne

    2016-08-01

    Full Text Available The aim of this article is to: Cover the basics of Computed Tomography (CT Brain imaging. Review relevant CT neuroanatomy. A CT image is produced by firing x-rays at a moving object which is then detected by an array of rotating detectors (Figure 1. The detected x-rays are then converted into a computerised signal which is used to produce a series of cross sectional images.

  16. A rare case of extensive skeletal muscle metastases in adenocarcinoma cervix identified by 18F-fluorodeoxyglucose positron emission tomography/computed tomography scan

    International Nuclear Information System (INIS)

    Vishnoi, Madan Gopal; Jain, Anurag; John, Arun Ravi; Paliwal, Dharmesh

    2016-01-01

    Adenocarcinoma cervix is an uncommon histological subtype of carcinoma cervix; further incidence of skeletal muscle metastases is even rarer. We report the identification of extensive fluorodeoxyglucose (FDG) avid metastatic skeletal muscle deposits in a known case of adenocarcinoma cervix. The largest lesion representative of muscle deposit in the right deltoid was histopathologically confirmed to be metastatic poorly differentiated carcinoma. This report also serves to highlight the importance of 18 F-FDG positron emission tomography/computed tomography (CT) as compared to conventional imaging modalities such as CT and ultrasonography and comments better over the description of invasiveness as well as the extent of disease in carcinoma cervix

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  18. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  19. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  20. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  1. Application of the axial tomography computed for the detection of bags of dampness in dry wood of Gmelina arborea (Roxb.); Aplicacion de la tomografia axial computarizada para la deteccion de bolsas de humedad en madera seca de Gmelina arborea (Roxb.)

    Energy Technology Data Exchange (ETDEWEB)

    Moya R, Roger; Munoz A, Freddy [Inst. Tecnologico de Costa Rica, Escuela de Ingenieria Forestal, Apdo. 159-7050, Cartago 7050(Costa Rica); Escalante, Ivan [Clinica Santa Fe, San Jose (Costa Rica)

    2006-07-01

    Gmelina arborea (Roxb.) is widely used for commercial reforestation in Costa Rica due to its excellent growth rate and productivity. However, during the lumber drying process, the wooden boards show non-uniform values of final moisture content (MC). The low uniformity in final MC is caused by the presence of wet pockets, originated during the growing process of the tree. The regions with wet pockets present zones with a high MC, which are hard to detect with traditional methods for MC measurements during the wood drying process. It is possible to detect and to set the limits of the presence of wet wood in Gmelina arborea boards using scanning computed tomography (CT-scanning), a technique applied in medical diagnostic. A board with wet pockets is shown in the CT-scanning images in clear color and with low values of the Hounsfield Unit (HU) or CT number. When these values were transformed to wood density, it was determined that wet pockets were in a density of around 190 kg/m{sup 3}, a value higher than normal wood. Also, it was possible to observe growth tree rings in the CT-scanning images, an important feature for dendrochronological research. The obtained results allowed showing that it is possible to apply this technique in the process of lumber production, to detect the zones with high MC in kiln dried Gmelina arborea wood. (author) [Spanish] Gmelina arborea (Roxb.) es muy utilizado para la reforestacion comercial en Costa Rica debido a su excelente tasa de crecimiento y la productividad. Sin embargo, durante el proceso de secado, las tablas de madera muestran uniformidad en los valores finales de contenido de humedad (MC). La escasa uniformidad final de MC es causado por la presencia de bolsas humedas, se origino durante el proceso de crecimiento del arbol. Las regiones que presentan bolsas de humedad con un alto MC son dificiles de detectar con los metodos tradicionales de mediciones de MC durante el proceso de secado de madera. Se muestra que es posible

  2. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    Science.gov (United States)

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (ptime of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Usefulness of the Bolus-Tracking Baseline Scan for the Diagnosis of Hepatic Steatosis in Abdominal Computed Tomography: A Feasibility Study

    International Nuclear Information System (INIS)

    Gossner, J.; Schäfer, S.

    2013-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a common pathology in western societies. Unenhanced computed tomography (CT) of the liver is a valuable tool in determining the presence of steatosis hepatis, but in most departments standard CT protocols of abdomen often do not include unenhanced scans anymore. In a small series of 22 patients the liver density was measured in the acquired low-dose baseline scan for bolus tracking and was compared to the measurement in a regular unenhanced CT scan of the upper abdomen. The mean difference between the unenhanced CT scan and the low-dose baseline scan was 3.4 HU (range 0.2–8.6 HU); the difference between these two scans was 5 HU or smaller in 82% of the patients. There was a significant difference between the two used CT scanners; this has to be kept in mind before implementing this approach into daily practice. All but one patient with fatty liver disease on unenhanced CT were diagnosed using the baseline scan. The baseline scan for bolus tracking may be useful for the diagnosis or in the followup of fatty liver disease

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  6. Prognostic impact of pre-transplantation computed tomography and 67gallium scanning in chemosensitive diffuse large B cell lymphoma patients undergoing hematopoietic stem-cell transplantation

    International Nuclear Information System (INIS)

    Escobar, Ignacio G.; Alonso, Pilar T.; Barrigon, Dolores C.; Perez-Simon, Jose A.; Mateos Manteca, Maria V.; San Miguel Izquierdo, Jesus F.

    2008-01-01

    In the present study, we evaluated computed tomography (CT) and 67 gallium scanning ( 67 Ga scan) pre-transplant as prognostic factors for overall survival (OS) and event-free survival (EFS) in patients with diffuse large B cell lymphoma, undergoing high-dose chemotherapy and stem-cell transplantation. Forty-two patients were included. Of these, 9 (21%) had both positive CT and 67 Ga scans, 17 (41%) negative results with both techniques, and 16 (38%) positive CT/negative 67 Ga scan. Whole-body planar imaging and single-photon emission computed tomography (SPECT) were performed 72 h after an intravenous administration of 67 Ga citrate measuring between 7 mCi and 10 mCi (259-370 MBq). Patients with positive CT/positive 67 Ga scan had a significantly worse EFS and OS at 5 years than those with negative 67 Ga scan regardless of whether it was associated with a positive or a negative CT scan (29% and 16% vs. 81% and 93% vs. 88% and 100%, respectively, P 67 Ga scan and those with positive CT/negative 67 Ga scan, with an EFS and OS at 5 years of 88% versus 81% and 100% versus 93%, respectively. In multivariate analysis, the presence of a pre-transplant positive CT/ 67 Ga scans adversely influenced both EFS and OS [HR 8, 95% confidence interval (CI) (1.4-38), P=0.03 and HR 2; 95% CI (1.3-8), P=0.02, respectively]. 67 Ga scan helps to identify, in the pre-transplant evaluation, two groups with a different outcome: one group of patients with positive CT and negative 67 Ga scans pre-transplant, who showed a favorable outcome with a low rate of relapse, and the other group of patients with both positive CT and 67 Ga scans pre-transplant, who showed a poor prognosis and did not benefit from autologous stem-cell transplantation. They should have been offered other therapeutic strategies. (author)

  7. Computerized axial tomography and diagnosis of multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Paulo R.M. Bittencourt

    1983-06-01

    Full Text Available Computed axial tomography (C.T. findings are illustrated in 3 patients who presented with C.T. changes suggesting respectively chronic M.S., acute M.S., and an appearance simulating a malignant tumour. Review of the literature shows that the chronic form with cerebral atrophy and low density lesions in the hemispheres is common in patients with a long history and is unlikely to cause diagnostic difficulty. The acute presentation is less common and could be confused with a variety of causes of multiple low density enhancing lesions. The C.T. diagnosis of M.S. is more difficult in rare cases in which plaques cause mass effect and show ring enhancement; all 3 such cases in the literature were subjected to cerebral biopsy.

  8. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  9. Influence of heart rhythm, breathing and arm position during computed tomography scanning on the registration accuracy of electro anatomical map (EAM) images, left atrium three-dimensional computed tomography angiography images, and fluoroscopy time during ablation to treat atrial fibrillation

    International Nuclear Information System (INIS)

    Chono, Taiki; Shimoshige, Shinya; Yoshikawa, Kenta; Mizonobe, Kazuhusa; Ogura, Keishi

    2013-01-01

    In CARTOMERGE for treatment of atrial fibrillation (AF) by ablation, by integrating electro anatomical map (EAM) and left atrium three-dimensional computed tomography angiography (3D-CTA) images, identification of the ablation points is simplified and the procedure can be made carried out more rapidly. However, the influence that heart rhythm, breathing and arm position during CT scanning have on registration accuracy and fluoroscopy time is not clear. To clarify the influence on registration accuracy and fluoroscopy time of heart rhythm, breathing and arm position during CT scanning. The patients were CT-scanned during both sinus rhythm (SR) and AF in each study subject. We evaluated the registration accuracy of images reconstructed between the cardiac cycle and assessed the registration accuracy and fluoroscopy time of images obtained during inspiratory breath-hold, expiratory breath-hold and up and down position of the arm. Although the registration accuracy of the EAM image and left atrium 3D-CTA image showed a significant difference during SR, no significant difference was seen during AF. Expiratory breath-hold and down position of the arm resulted in the highest registration accuracy and the shortest fluoroscopy time. However, arm position had no significant effect on registration accuracy. Heart rhythm and breathing during CT scanning have a significant effect on the registration accuracy of EAM images, left atrium 3D-CTA images, and fluoroscopy time. (author)

  10. Computed tomography findings in convergent strabismus fixus

    International Nuclear Information System (INIS)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio

    1995-01-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author)

  11. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  12. Dual-detection confocal fluorescence microscopy: fluorescence axial imaging without axial scanning.

    Science.gov (United States)

    Lee, Dong-Ryoung; Kim, Young-Duk; Gweon, Dae-Gab; Yoo, Hongki

    2013-07-29

    We propose a new method for high-speed, three-dimensional (3-D) fluorescence imaging, which we refer to as dual-detection confocal fluorescence microscopy (DDCFM). In contrast to conventional beam-scanning confocal fluorescence microscopy, where the focal spot must be scanned either optically or mechanically over a sample volume to reconstruct a 3-D image, DDCFM can obtain the depth of a fluorescent emitter without depth scanning. DDCFM comprises two photodetectors, each with a pinhole of different size, in the confocal detection system. Axial information on fluorescent emitters can be measured by the axial response curve through the ratio of intensity signals. DDCFM can rapidly acquire a 3-D fluorescent image from a single two-dimensional scan with less phototoxicity and photobleaching than confocal fluorescence microscopy because no mechanical depth scans are needed. We demonstrated the feasibility of the proposed method by phantom studies.

  13. Prediction of intramuscular fat content and shear force in Texel lamb loins using combinations of different X-ray computed tomography (CT) scanning techniques.

    Science.gov (United States)

    Clelland, N; Bunger, L; McLean, K A; Knott, S; Matthews, K R; Lambe, N R

    2018-06-01

    Computed tomography (CT) parameters, including spiral computed tomography scanning (SCTS) parameters, intramuscular fat (IMF) and mechanically measured shear force were derived from two previously published studies. Purebred Texel (n = 377) of both sexes, females (n = 206) and intact males (n = 171) were used to investigate the prediction of IMF and shear force in the loin. Two and three dimensional CT density information was available. Accuracies in the prediction of shear force and IMF ranged from R 2 0.02 to R 2 0.13 and R 2 0.51 to R 2 0.71 respectively, using combinations of SCTS and CT scan information. The prediction of mechanical shear force could not be achieved at an acceptable level of accuracy employing SCTS information. However, the prediction of IMF in the loin employing information from SCTS and additional information from standard CT scans was successful, providing evidence that the prediction of IMF and related meat eating quality (MEQ) traits for Texel lambs in vivo can be achieved. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    Science.gov (United States)

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  1. Effect of length and location of edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography scans.

    Science.gov (United States)

    Jamjoom, Faris Z; Kim, Do-Gyoon; Lee, Damian J; McGlumphy, Edwin A; Yilmaz, Burak

    2018-02-05

    Effects of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography (CBCT) scans has not been investigated. To evaluate the effect of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into CBCT scans using different methods. Direct digital scans of a completely dentate master model with removable radiopaque teeth were made using an intraoral scanner, and digital scans of stone duplicates of the master model were made using a laboratory scanner. Specific teeth were removed to simulate different clinical situations and their CBCT scans were made. Surface scans were registered onto the CBCT scans. Radiographic templates for each clinical situation were also fabricated and used during CBCT scans of the master models. Using metrology software, three-dimensional (3D) deviation was measured on standard tesselation language (STL) files created from the CBCT scans against an STL file of the master model created from a CBCT scan. Statistical analysis was done using the MIXED procedure in a statistical software and Tukey HSD test (α =.05). The interaction between location and method was significant (P = .009). Location had no significant effect on registration methods (P > .05), but on the radiographic templates (P = .011). Length of the edentulous area did not have any significant effect (P > .05). Accuracy of digital image registration methods was similar and higher than that of radiographic templates in all clinical situations. Tooth-bound radiographic templates were significantly more accurate than the free-end templates. The results of this study suggest using image registration instead of radiographic templates when planning dental implants, particularly in free-end situations. © 2018 Wiley Periodicals, Inc.

  2. Evaluation of an exposed-radiation dose on a dual-source cardiac computed tomography examination with a prospective electrocardiogram-gated fast dual spiral scan

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Koshida, Kichiro; Koshida, Haruka; Sakuta, Keita; Hayashi, Hiroyuki; Takata, Tadanori; Horii, Junsei; Kawai, Keiichi; Yamamoto, Tomoyuki

    2012-01-01

    We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.03 mGy for the breast, 9.96 mGy for the heart, 6.60 mGy for the lung, 6.48 mGy for the bone marrow, 9.73 mGy for the thymus, and 4.58 mGy for the skin. These values were about 5% of the absorbed doses for the retrospective ECG-gated dual spiral scan. However, the absorbed dose differed greatly at each scan, especially in the external organs such as the breast. For effective and safe use of the prospective ECG-gated fast dual spiral scan, it is necessary to understand these characteristics sufficiently. (author)

  3. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  4. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Isherwood, I.; Antoun, N.M.

    1984-01-01

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  5. Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Matheus L. [Dept. of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Campinas (Brazil); Tosoni, Guilherme M. [Dept. of Oral Diagnosis and Surgery, Araraquara Dental School, Sao Paulo State University, Araraquara (Brazil); Lindsey, David H.; Mendoza, Kristopher; Tetradis, Sotirios; Mallya, Sanjay M. [Section of Oral and Maxillofacial Radiology, School of Dentistry, University of California, Los Angeles (United States)

    2014-12-15

    To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K{sub 2}HPO{sub 4} solutions were measured. The relationship between CT number and K{sub 2}HPO{sub 4} concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. The relationship between K{sub 2}HPO{sub 4} concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

  6. Computed tomography in osteoid osteoma

    International Nuclear Information System (INIS)

    Vicens, J.L.; Aubspin, D.; Buchon, R.; Schoenenberger, P.; Flageat, J.

    1989-01-01

    Four cases of suspected osteoid osteoma were evaluated by computed tomography (CT). The role of CT was related, as a key diagnostic tool: radionuclide imaging is helpful in directing subsequent CT scans, which allows the study of complex anatomical sites (spine) or the analysis of atypical lesions (invisible nidus, sclerosis or lytic lesions, double nidus...). CT provides the surgeon with the exact location and extent of the lesion, and thus, CT may allow a more limited surgical resection of the involved bone [fr

  7. Axial tomography in 3D live cell microscopy

    Science.gov (United States)

    Richter, Verena; Bruns, Sarah; Bruns, Thomas; Piper, Mathis; Weber, Petra; Wagner, Michael; Cremer, Christoph; Schneckenburger, Herbert

    2017-07-01

    A miniaturized setup for sample rotation on a microscope stage has been developed, combined with light sheet, confocal or structured illumination microscopy and applied to living cells as well as to small organisms. This setup permits axial tomography with improved visualization of single cells or small cell clusters as well as an enhanced effective 3D resolution upon sample rotation.

  8. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  9. Scanning Microwave Induced Acoustic Tomography

    National Research Council Canada - National Science Library

    Wang, Lihong V

    2002-01-01

    .... Specifically, our accomplishments include (1) an exact and an approximate time-domain reconstruction algorithm for thermoacoustic tomography in a spherical geometry was derived and published, (2...

  10. Dental image replacement on cone beam computed tomography with three-dimensional optical scanning of a dental cast, occlusal bite, or bite tray impression.

    Science.gov (United States)

    Kang, S-H; Lee, J-W; Lim, S-H; Kim, Y-H; Kim, M-K

    2014-10-01

    The goal of the present study was to compare the accuracy of dental image replacement on a cone beam computed tomography (CBCT) image using digital image data from three-dimensional (3D) optical scanning of a dental cast, occlusal bite, and bite tray impression. A Bracket Typodont dental model was used. CBCT of the dental model was performed and the data were converted to stereolithography (STL) format. Three experimental materials, a dental cast, occlusal bite, and bite tray impression, were optically scanned in 3D. STL files converted from the CBCT of the Typodont model and the 3D optical-scanned STL files of the study materials were image-registered. The error range of each methodology was measured and compared with a 3D optical scan of the Typodont. For the three materials, the smallest error observed was 0.099±0.114mm (mean error±standard deviation) for registering the 3D optical scan image of the dental cast onto the CBCT dental image. Although producing a dental cast can be laborious, the study results indicate that it is the preferred method. In addition, an occlusal bite is recommended when bite impression materials are used. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Dimensional accuracy of digital dental models from cone-beam computed tomography scans of alginate impressions according to time elapsed after the impressions.

    Science.gov (United States)

    Lee, Sang-Mi; Hou, Yanan; Cho, Jin-Hyoung; Hwang, Hyeon-Shik

    2016-02-01

    Our objective was to investigate the dimensional accuracy of digital dental models obtained from the cone-beam computed tomography (CBCT) scans of alginate impressions according to the time elapsed after the impressions were taken. Alginate impressions were obtained of 20 adults using 2 alginate materials: Alginoplast (Heraeus Kulzer, Hanau, Germany) and Cavex (Cavex Holland, Haarlem, The Netherlands). These impressions were stored in wet conditions and scanned by CBCT immediately after impression-taking and after storage times of 12, 24, 36, 48, 60, and 72 hours. After reconstruction of the 3-dimensional digital dental models, the models were measured, and the data were analyzed to determine the dimensional changes according to the time elapsed. The changes within the measurement error were regarded as clinically acceptable in this study. The measurement errors ranged from 0.27 to 0.29 mm in the digital dental models obtained from CBCT scans of the alginate impressions. All measurements showed decreasing accuracy with greater elapsed time after the impressions were taken. Changes above the measurement error occurred at 24 and 36 hours for Cavex and Alginoplast, respectively. Digital dental models can be obtained from CBCT scans of alginate impressions without sending them to a remote laboratory. However, the impressions need to be scanned within 24 hours; otherwise, dimensional changes lead to errors that exceed the error of measurement. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  12. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  13. Computer graphic display of cardiac CT scans

    International Nuclear Information System (INIS)

    Palmer, R.; Carlsson, E.

    1982-01-01

    In order to improve spatial conception and quantitative assessment of the cardiac structures based on cardiac computed tomography, methods for computer graphic display were developed. Excised hearts and living dogs with myocardial infarctions were subjected to CT scanning. The data on the scanner tapes were processed to provide isodensity plots, linear section plots, time-weighted integrated isodensity plots as well as topographical density displays and three-dimensional spatial reconstructions of single and multi-layer scans. (orig.)

  14. Osteoporosis markers on low-dose lung cancer screening chest computed tomography scans predict all-cause mortality

    Energy Technology Data Exchange (ETDEWEB)

    Buckens, C.F. [University Medical Center Utrecht, Radiology Department, Utrecht (Netherlands); University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Graaf, Y. van der [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Verkooijen, H.M.; Mali, W.P.; Jong, P.A. de [University Medical Center Utrecht, Radiology Department, Utrecht (Netherlands); Isgum, I.; Mol, C.P. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Verhaar, H.J. [University Medical Center Utrecht, Department of Geriatric Medicine, Utrecht (Netherlands); Vliegenthart, R.; Oudkerk, M. [Medical Center Groningen, Department of Radiology, Utrecht (Netherlands); Aalst, C.M. van; Koning, H.J. de [Erasmus MC Rotterdam, Department of Public Health, Rotterdam (Netherlands)

    2015-01-15

    Further survival benefits may be gained from low-dose chest computed tomography (CT) by assessing vertebral fractures and bone density. We sought to assess the association between CT-measured vertebral fractures and bone density with all-cause mortality in lung cancer screening participants. Following a case-cohort design, lung cancer screening trial participants (N = 3,673) who died (N = 196) during a median follow-up of 6 years (inter-quartile range: 5.7-6.3) were identified and added to a random sample of N = 383 from the trial. We assessed vertebral fractures using Genant and acute;s semiquantative method on sagittal reconstructions and measured bone density (Hounsfield Units (HU)) in vertebrae. Cox proportional hazards modelling was used to determine if vertebral fractures or bone density were independently predictive of mortality. The prevalence of vertebral fractures was 35 % (95 % confidence interval 30-40 %) among survivors and 51 % (44-58 %) amongst cases. After adjusting for age, gender, smoking status, pack years smoked, coronary and aortic calcium volume and pulmonary emphysema, the adjusted hazard ratio (HR) for vertebral fracture was 2.04 (1.43-2.92). For each 10 HU decline in trabecular bone density, the adjusted HR was 1.08 (1.02-1.15). Vertebral fractures and bone density are independently associated with all-cause mortality. (orig.)

  15. Osteoporosis markers on low-dose lung cancer screening chest computed tomography scans predict all-cause mortality

    International Nuclear Information System (INIS)

    Buckens, C.F.; Graaf, Y. van der; Verkooijen, H.M.; Mali, W.P.; Jong, P.A. de; Isgum, I.; Mol, C.P.; Verhaar, H.J.; Vliegenthart, R.; Oudkerk, M.; Aalst, C.M. van; Koning, H.J. de

    2015-01-01

    Further survival benefits may be gained from low-dose chest computed tomography (CT) by assessing vertebral fractures and bone density. We sought to assess the association between CT-measured vertebral fractures and bone density with all-cause mortality in lung cancer screening participants. Following a case-cohort design, lung cancer screening trial participants (N = 3,673) who died (N = 196) during a median follow-up of 6 years (inter-quartile range: 5.7-6.3) were identified and added to a random sample of N = 383 from the trial. We assessed vertebral fractures using Genant and acute;s semiquantative method on sagittal reconstructions and measured bone density (Hounsfield Units (HU)) in vertebrae. Cox proportional hazards modelling was used to determine if vertebral fractures or bone density were independently predictive of mortality. The prevalence of vertebral fractures was 35 % (95 % confidence interval 30-40 %) among survivors and 51 % (44-58 %) amongst cases. After adjusting for age, gender, smoking status, pack years smoked, coronary and aortic calcium volume and pulmonary emphysema, the adjusted hazard ratio (HR) for vertebral fracture was 2.04 (1.43-2.92). For each 10 HU decline in trabecular bone density, the adjusted HR was 1.08 (1.02-1.15). Vertebral fractures and bone density are independently associated with all-cause mortality. (orig.)

  16. SU-F-R-40: Robustness Test of Computed Tomography Textures of Lung Tissues to Varying Scanning Protocols Using a Realistic Phantom Environment

    International Nuclear Information System (INIS)

    Lee, S; Markel, D; Hegyi, G; El Naqa, I

    2016-01-01

    Purpose: The reliability of computed tomography (CT) textures is an important element of radiomics analysis. This study investigates the dependency of lung CT textures on different breathing phases and changes in CT image acquisition protocols in a realistic phantom setting. Methods: We investigated 11 CT texture features for radiation-induced lung disease from 3 categories (first-order, grey level co-ocurrence matrix (GLCM), and Law’s filter). A biomechanical swine lung phantom was scanned at two breathing phases (inhale/exhale) and two scanning protocols set for PET/CT and diagnostic CT scanning. Lung volumes acquired from the CT images were divided into 2-dimensional sub-regions with a grid spacing of 31 mm. The distribution of the evaluated texture features from these sub-regions were compared between the two scanning protocols and two breathing phases. The significance of each factor on feature values were tested at 95% significance level using analysis of covariance (ANCOVA) model with interaction terms included. Robustness of a feature to a scanning factor was defined as non-significant dependence on the factor. Results: Three GLCM textures (variance, sum entropy, difference entropy) were robust to breathing changes. Two GLCM (variance, sum entropy) and 3 Law’s filter textures (S5L5, E5L5, W5L5) were robust to scanner changes. Moreover, the two GLCM textures (variance, sum entropy) were consistent across all 4 scanning conditions. First-order features, especially Hounsfield unit intensity features, presented the most drastic variation up to 39%. Conclusion: Amongst the studied features, GLCM and Law’s filter texture features were more robust than first-order features. However, the majority of the features were modified by either breathing phase or scanner changes, suggesting a need for calibration when retrospectively comparing scans obtained at different conditions. Further investigation is necessary to identify the sensitivity of individual image

  17. SU-F-R-40: Robustness Test of Computed Tomography Textures of Lung Tissues to Varying Scanning Protocols Using a Realistic Phantom Environment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Markel, D; Hegyi, G [Medical Physics Unit, McGill University, Montreal, Quebec (Canada); El Naqa, I [University of Michigan, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: The reliability of computed tomography (CT) textures is an important element of radiomics analysis. This study investigates the dependency of lung CT textures on different breathing phases and changes in CT image acquisition protocols in a realistic phantom setting. Methods: We investigated 11 CT texture features for radiation-induced lung disease from 3 categories (first-order, grey level co-ocurrence matrix (GLCM), and Law’s filter). A biomechanical swine lung phantom was scanned at two breathing phases (inhale/exhale) and two scanning protocols set for PET/CT and diagnostic CT scanning. Lung volumes acquired from the CT images were divided into 2-dimensional sub-regions with a grid spacing of 31 mm. The distribution of the evaluated texture features from these sub-regions were compared between the two scanning protocols and two breathing phases. The significance of each factor on feature values were tested at 95% significance level using analysis of covariance (ANCOVA) model with interaction terms included. Robustness of a feature to a scanning factor was defined as non-significant dependence on the factor. Results: Three GLCM textures (variance, sum entropy, difference entropy) were robust to breathing changes. Two GLCM (variance, sum entropy) and 3 Law’s filter textures (S5L5, E5L5, W5L5) were robust to scanner changes. Moreover, the two GLCM textures (variance, sum entropy) were consistent across all 4 scanning conditions. First-order features, especially Hounsfield unit intensity features, presented the most drastic variation up to 39%. Conclusion: Amongst the studied features, GLCM and Law’s filter texture features were more robust than first-order features. However, the majority of the features were modified by either breathing phase or scanner changes, suggesting a need for calibration when retrospectively comparing scans obtained at different conditions. Further investigation is necessary to identify the sensitivity of individual image

  18. Digital dissection - using contrast-enhanced computed tomography scanning to elucidate hard- and soft-tissue anatomy in the Common Buzzard Buteo buteo.

    Science.gov (United States)

    Lautenschlager, Stephan; Bright, Jen A; Rayfield, Emily J

    2014-04-01

    Gross dissection has a long history as a tool for the study of human or animal soft- and hard-tissue anatomy. However, apart from being a time-consuming and invasive method, dissection is often unsuitable for very small specimens and often cannot capture spatial relationships of the individual soft-tissue structures. The handful of comprehensive studies on avian anatomy using traditional dissection techniques focus nearly exclusively on domestic birds, whereas raptorial birds, and in particular their cranial soft tissues, are essentially absent from the literature. Here, we digitally dissect, identify, and document the soft-tissue anatomy of the Common Buzzard (Buteo buteo) in detail, using the new approach of contrast-enhanced computed tomography using Lugol's iodine. The architecture of different muscle systems (adductor, depressor, ocular, hyoid, neck musculature), neurovascular, and other soft-tissue structures is three-dimensionally visualised and described in unprecedented detail. The three-dimensional model is further presented as an interactive PDF to facilitate the dissemination and accessibility of anatomical data. Due to the digital nature of the data derived from the computed tomography scanning and segmentation processes, these methods hold the potential for further computational analyses beyond descriptive and illustrative proposes. © 2013 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  19. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  20. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  1. Three-dimensional cranio-facial computed tomography

    International Nuclear Information System (INIS)

    Pozzi Muccelli, R.; Stagul, F.; Pozzi Muccelli, F.; Zuiani, C.; Smathers, R.

    1986-01-01

    Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy

  2. Three-dimensional cranio-facial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Muccelli, R; Stagul, F; Pozzi Muccelli, F; Zuiani, C; Smathers, R

    1986-01-01

    Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

  3. Augmented Quadruple-Phase Contrast Media Administration and Triphasic Scan Protocol Increases Image Quality at Reduced Radiation Dose During Computed Tomography Urography.

    Science.gov (United States)

    Saade, Charbel; Mohamad, May; Kerek, Racha; Hamieh, Nadine; Alsheikh Deeb, Ibrahim; El-Achkar, Bassam; Tamim, Hani; Abdul Razzak, Farah; Haddad, Maurice; Abi-Ghanem, Alain S; El-Merhi, Fadi

    The aim of this article was to investigate the opacification of the renal vasculature and the urogenital system during computed tomography urography by using a quadruple-phase contrast media in a triphasic scan protocol. A total of 200 patients with possible urinary tract abnormalities were equally divided between 2 protocols. Protocol A used the conventional single bolus and quadruple-phase scan protocol (pre, arterial, venous, and delayed), retrospectively. Protocol B included a quadruple-phase contrast media injection with a triphasic scan protocol (pre, arterial and combined venous, and delayed), prospectively. Each protocol used 100 mL contrast and saline at a flow rate of 4.5 mL. Attenuation profiles and contrast-to-noise ratio of the renal arteries, veins, and urogenital tract were measured. Effective radiation dose calculation, data analysis by independent sample t test, receiver operating characteristic, and visual grading characteristic analyses were performed. In arterial circulation, only the inferior interlobular arteries in both protocols showed a statistical significance (P contrast-to-noise ratio than protocol A (protocol B: 22.68 ± 13.72; protocol A: 14.75 ± 5.76; P contrast media and triphasic scan protocol usage increases the image quality at a reduced radiation dose.

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  6. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  7. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  10. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  11. Bleomycin-Induced Pulmonary Changes on Restaging Computed Tomography Scans in Two Thirds of Testicular Cancer Patients Show No Correlation With Fibrosis Markers.

    Science.gov (United States)

    den Hollander, Martha W; Westerink, Nico-Derk L; Lubberts, Sjoukje; Bongaerts, Alfons H H; Wolf, Rienhart F E; Altena, Renska; Nuver, Janine; Oosting, Sjoukje F; de Vries, Elisabeth G E; Walenkamp, Anna M E; Meijer, Coby; Gietema, Jourik A

    2016-08-01

    In metastatic testicular cancer patients treated with bleomycin, etoposide, and cisplatin (BEP) chemotherapy, bleomycin-induced pneumonitis is a well-known and potentially fatal side effect. We sought to determine the prevalence of lesions as signs of bleomycin-induced pulmonary changes on restaging computed tomography (CT) scans after treatment and to ascertain whether fibrosis markers were predictive of these changes. This prospective nonrandomized cohort study included metastatic testicular cancer patients, 18-50 years of age, treated with BEP chemotherapy. Restaging CT scans were examined for lesions as signs of bleomycin-induced pulmonary changes by two independent radiologists and graded as minor, moderate, or severe. Plasma samples were collected before, during, and after treatment and were quantified for transforming growth factor-β1 (TGF-β1), growth differentiation factor-15 (GDF-15), and high-sensitivity C-reactive protein (hs-CRP). In total, 66 patients were included: forty-five (68%) showed signs of bleomycin-induced pulmonary changes on the restaging CT scan, 37 of which were classified as minor and 8 as moderate. No differences in TGF-β1, GDF-15, or hs-CRP plasma levels were found between these groups. Bleomycin-induced pulmonary changes are common on restaging CT scans after BEP chemotherapy for metastatic testicular cancer. Changes in TGF-β1, GDF-15, and hs-CRP plasma levels do not differ between patients with and without radiological lesions as signs of bleomycin-induced pulmonary changes and are therefore not helpful as predictive biomarkers. Bleomycin-induced pneumonitis (BIP) is a well-known and potentially fatal side effect in metastatic testicular cancer patients treated with bleomycin, etoposide, and cisplatin chemotherapy. Currently, the decision to discontinue bleomycin administration is made during treatment and is based on clinical signs. An upfront or early marker or biomarker that identifies patients likely to develop BIP would be

  12. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  13. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  14. Endodontic management of mandibular third molar with three mesial roots using spiral computed tomography scan as a diagnostic aid: a case report.

    Science.gov (United States)

    Tomar, Deepak; Dhingra, Anil; Tomer, Anil; Sharma, Shalini; Sharma, Vivek; Miglani, Anjali

    2013-05-01

    Aberrant root canal anatomy is diagnostically and clinically challenging for clinicians. The most common root canal configuration of human molars is 2 roots and 3 canals, but various combinations may still exist. Third molars are known to have the most unusual anatomy among human teeth. Restorative, prosthetic, and orthodontic considerations often require endodontic treatment of third molars in order for them to be retained as functional components of the dental arch. The present case report demonstrates unusual root canal morphology of the mandibular third molar. Roentgenographic examination, which included spiral CT scan, revealed 3 separate mesial roots in tooth #48 with 3 independent canals and 3 canal orifices, indicating an endodontic rarity. The present case report puts impetus on exploration of additional canals using advanced diagnostic aids, such as spiral computed tomography, which can have a huge impact on the successful outcome of endodontic therapy. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  16. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  17. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  18. A study on optimal scan conditions of big bore multi-slice computed tomography based on radiation dose and image noise

    International Nuclear Information System (INIS)

    Lee, J. S.; Ye, S. J.; Kim, E. H.

    2011-01-01

    The newly introduced Big Bore computed tomography (CT) has a possibility to increase the tube current product scan time (mA s) for compensation of image degradation due to larger gentry opening without sound guideline. The objective of this paper is to derive optimal scan conditions for Big Bore CT scanner, mainly relating to the dose of diagnostic CT. The weighted CT dose index (CTDI w ) was estimated at five typical protocols, such as head and neck, brain, paediatric, chest and abdomen. Noises were analysed in a circle of 1 or 2 cm of diameter in CT image slice. The results showed that measured CTDI w values generally follow the theoretical rule at all scanning conditions of every protocol. Although image noises decrease with increment of mA s, analysed image noises do follow the theoretical rule, but only in specific protocols. This phenomenon is presumed to result from the photon energy spectra arriving at the detection system of the Big Bore scanner. (authors)

  19. Computational analysis of a multistage axial compressor

    Science.gov (United States)

    Mamidoju, Chaithanya

    Turbomachines are used extensively in Aerospace, Power Generation, and Oil & Gas Industries. Efficiency of these machines is often an important factor and has led to the continuous effort to improve the design to achieve better efficiency. The axial flow compressor is a major component in a gas turbine with the turbine's overall performance depending strongly on compressor performance. Traditional analysis of axial compressors involves throughflow calculations, isolated blade passage analysis, Quasi-3D blade-to-blade analysis, single-stage (rotor-stator) analysis, and multi-stage analysis involving larger design cycles. In the current study, the detailed flow through a 15 stage axial compressor is analyzed using a 3-D Navier Stokes CFD solver in a parallel computing environment. Methodology is described for steady state (frozen rotor stator) analysis of one blade passage per component. Various effects such as mesh type and density, boundary conditions, tip clearance and numerical issues such as turbulence model choice, advection model choice, and parallel processing performance are analyzed. A high sensitivity of the predictions to the above was found. Physical explanation to the flow features observed in the computational study are given. The total pressure rise verses mass flow rate was computed.

  20. Noncontrast chest computed tomography immediately after transarterial chemoembolization in patients with hepatocellular carcinoma: Clinical benefits and effect of radiation reduction on image quality in low-dose scanning

    International Nuclear Information System (INIS)

    Choi, Joon-Il; Kim, Hyun Beom; Kim, Min Ju; Lee, Jong Seok; Koh, Young Whan; An, Sang Bu; Ko, Heung-kyu; Park, Joong-Won

    2011-01-01

    Purpose: To evaluate the clinical benefits of noncontrast chest computed tomography (CT) immediately after transarterial chemoembolization in patients with hepatocellular carcinoma and to assess the effect of radiation reduction on image quality in low-dose scanning. Materials and methods: From June to October 2010, we performed standard-dose, noncontrast chest CTs immediately after transarterial chemoembolization in 160 patients and low-dose CTs in 88 patients. We reviewed the entire noncontrast chest CTs and follow-up CTs to reveal the clinical benefits of CT evaluation immediately after transarterial chemoembolization. Using two independent readers, we also retrospectively evaluated the radiation dose and image quality in terms of the image noise, contrast between the liver parenchyma and iodized oil and diagnostic acceptability for the evaluation of treatment response after transarterial chemoembolization. Results: In 5.2% of the patients, additional treatment was performed immediately after the interpretation of the noncontrast chest CT, and additional pulmonary lesions were found in 8.5% of the patients. The measured mean dose-length product for the low-dose scanning was 18.4% of that of the standard-dose scanning. The image noise was significantly higher with the low-dose scanning (p < 0.001). However, all of the low-dose CT scans were diagnostically acceptable, and the mean scores for the subjective assessments of the contrast and diagnostic acceptability showed no significant differences for either reader. Conclusion: A noncontrast chest CT immediately after transarterial chemoembolization has some clinical benefits for immediate decision making and detecting pulmonary lesions. Low-dose, noncontrast chest CTs immediately after transarterial chemoembolization consistently provide diagnostically acceptable images and information on treatment response in patients who have undergone transarterial chemoembolization.

  1. Computed tomography scan in supine and prone positions: an alternative method to detect intramural gas in emphysematous cystitis and to evaluate efficacy after adjuvant continuous intravesical irrigation treatment.

    Science.gov (United States)

    Cortés-González, Jeff R; Ortiz-Lara, Gerardo E; Salinas, Matías; Hernández-Galván, Fernando; Gómez-Guerra, Lauro S

    2013-04-01

    To evaluate the efficacy of continuous intravesical irrigation with saline plus amikacin as adjuvant therapy and to evaluate the computed tomography (CT) scan in supine and prone positions (CystoCT scan) as an alternative diagnostic and evaluation method of intramural gas in emphysematous cystitis (EC) before and after treatment. Consecutive patients with a diagnosis of EC who were hospitalized between March 2006 and January 2011 were investigated. The diagnosis was made by CystoCT scan. Treatment consisted of intravenous antibiotics, control of concomitant diseases, and placement of a 3-way urinary catheter for continuous irrigation of 500 mg of amikacin diluted in 1 l of saline given on days 0, 3, and 7. Treatment was considered successful when there was an absence of gas in the bladder wall, the urine culture was negative, there was clinical improvement, and there was an absence of toxicity. Eleven patients were hospitalized with a diagnosis of EC during the study period. Four were excluded from the study, 2 due to the lack of confirmation of the diagnosis with the CystoCT scan. Treatment was successful in all patients; for 6 (86%) this was achieved in 3 days and for 1 (14%) in 7 days. No toxicity was reported. Continuous intravesical irrigation with saline plus amikacin as adjuvant treatment of EC is an inexpensive, effective, and safe tool that might help conventional treatment and provide a rapid recovery. The CystoCT scan is an alternative method to diagnose and evaluate intramural gas in EC patients. These findings should be challenged in a randomized, multi-centre, placebo-controlled clinical trial.

  2. Dosimetry in Computed Tomography head and neck scans; Dosimetria em varreduras de Tomografia Computadorizada de cabeça e pescoço

    Energy Technology Data Exchange (ETDEWEB)

    Gómez, A.M.L.; Santana, P.C.; Mourão, A.P., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais (UFMG), Berlo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Non-invasive diagnostic methods for X-rays, such as computed tomography (CT), have shown rapid growth in radiology services. There is concern about the radiation doses deposited in patients because the CT scans are the ones that contribute most to the dose increase in the population. The legislation for regulating patient dose levels only imposes an upper limit for a given test, depending on the region of the body to be irradiated. Therefore, it is necessary to know the dose values deposited in patients referring to routine protocols used in radiology services and propose an optimization of these according to the principles of radiological protection. Experiments were performed to determine the dose profile deposited in routine adult patient head scans using a male anthropomorphic simulator. Radiochromic film strips were introduced in the central region of the simulator to record the dose profile in the head and neck region and thus determine the air kerma values within the simulator object. Four scans were performed on a General Electric 64-channel tomograph programmed in helical mode and the scans were made with voltages of 80, 100 and 120 kV, and fixed current and automatic current control were used. The mean values recorded on the strips ranged from 14.82 to 22.98 mGy. Imaging noise analyzes were performed so that for all the scans the images obtained were considered of diagnostic quality and the Kerma values in the air when converted to absorbed dose are diagnostic parameters acceptable in the Brazilian legislation.

  3. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  5. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  6. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  7. Getting a CAT Scan (For Kids)

    Medline Plus

    Full Text Available ... site Sitio para adolescentes Body Mind Sexual Health Food & ... stands for "computerized axial tomography." Translated, that means a scanner takes computer pictures of what's going on inside your body. The scan itself ...

  8. Computed Tomography Study Of Complicated Bacterial Meningitis ...

    African Journals Online (AJOL)

    To monitor the structural intracranial complications of bacterial meningitis using computed tomography (CT) scan. Retrospective study of medical and radiological records of patients who underwent CT scan over a 4 year period. AUniversityTeachingHospital in a developing country. Thirty three patients with clinically and ...

  9. Orbital computed tomography: technical aspects

    International Nuclear Information System (INIS)

    Beck, T.J.; Rosenbaum, A.E.; Miller, N.R.

    1982-01-01

    Computed tomographic scanning has revolutionized the diagnosis and management of orbital disease. The best use of this methodology requires knowledge of the principles and appropriate attention to scanning protocols. Computed tomographic scanning of the orbit is a demanding technique requiring thin sections through planes precisely positioned from the topographical anatomy. Ideally, orbital CT should include both transverse axial and coronal sections: The pathological condition and its plane of growth will influence the selection of the optimal plane or section. Coronal sections may be obtained either directly or indirectly by computer reconstruction from contiguous transverse images. Sagittal or oblique sections or both also are useful and may be obtained directly or indirectly. Difficulty in patient positioning may preclude direct sagittal imaging, however. The use of intravenous contrast enhancement is not necessary as a routine technique unless a mass is identified or suspected. Where surgical resection or biopsy of a space-occupying lesion is contemplated, contrast enhancement can be valuable in assessing relative vascularity and aiding diagnostic specificity. It should be continually emphasized that CT is a powerful technology which, in orbital diagnosis, produces the highest yield when clinician and radiologist collaborate in the radiodiagnostic workup. The clinical information supplied by the referring ophthalmologist is used by the radiologist both in the selection of the appropriate techniques for investigation and in striving to achieve the most specific conclusion

  10. Value of computed tomography for evaluating the sub glottis in laryngeal and hypopharyngeal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Souza, Ricardo Pires de; Barros, Nestor de; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza; Rapoport, Abrao; Cerri, Giovanni Guido

    2007-01-01

    Context And Objective: Sub glottic involvement in squamous cell carcinoma is a determining factor for contraindicating conservative partial surgery. The subglottis is easily identified by axial computed tomography sections. The present study aimed to evaluate the occurrence of false-negative and false-positive results, and the overall accuracy of staging by computed tomography, in order to detect the involvement of the subglottic laryngeal compartment, in cases of laryngeal and hypopharyngeal squamous cell carcinoma. Design And Setting: Retrospective, non-randomized study of patients treated at Hospital Heliopolis, Sao Paulo, Brazil. Methods: Computed tomography scans were performed on third-generation equipment with 5-mm slice thickness. Afterwards, all patients underwent surgical and anatomopathological examinations as the gold standard procedures. Results: Among 60 patients, 14 were diagnosed with subglottic extension by surgical and histopathological examination. There were three false-negative and no false-positive results from computed tomography scans. The sensitivity and negative predictive value were 100.0%. Accuracy was 95.0%, specificity was 93.5% and positive predictive value was 82.4%. Conclusions: Computed tomography could serve as a powerful auxiliary method for staging laryngeal and hypopharyngeal cancer. However, precautions should be taken in analyzing computed tomography scan data, because vegetating lesions may also be projected into the subglottic compartment, without real involvement of the subglottis, which may cause a false-positive result. (author)

  11. Value of computed tomography for evaluating the sub glottis in laryngeal and hypopharyngeal squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Ricardo Pires de; Barros, Nestor de; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza; Rapoport, Abrao; Cerri, Giovanni Guido [Hospital Heliopolis, Sao Paulo, SP (Brazil). Dept. de Cirurgia de Cabeca e Pescoco, Otorrinolaringologia e Imagem]. E-mail: ricapires@ig.com.br; olger1@uol.com.br

    2007-03-15

    Context And Objective: Sub glottic involvement in squamous cell carcinoma is a determining factor for contraindicating conservative partial surgery. The subglottis is easily identified by axial computed tomography sections. The present study aimed to evaluate the occurrence of false-negative and false-positive results, and the overall accuracy of staging by computed tomography, in order to detect the involvement of the subglottic laryngeal compartment, in cases of laryngeal and hypopharyngeal squamous cell carcinoma. Design And Setting: Retrospective, non-randomized study of patients treated at Hospital Heliopolis, Sao Paulo, Brazil. Methods: Computed tomography scans were performed on third-generation equipment with 5-mm slice thickness. Afterwards, all patients underwent surgical and anatomopathological examinations as the gold standard procedures. Results: Among 60 patients, 14 were diagnosed with subglottic extension by surgical and histopathological examination. There were three false-negative and no false-positive results from computed tomography scans. The sensitivity and negative predictive value were 100.0%. Accuracy was 95.0%, specificity was 93.5% and positive predictive value was 82.4%. Conclusions: Computed tomography could serve as a powerful auxiliary method for staging laryngeal and hypopharyngeal cancer. However, precautions should be taken in analyzing computed tomography scan data, because vegetating lesions may also be projected into the subglottic compartment, without real involvement of the subglottis, which may cause a false-positive result. (author)

  12. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  13. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  14. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic. (orig.)

  15. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  16. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic

  17. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  18. Whole-body computed tomography in trauma patients: optimization of the patient scanning position significantly shortens examination time while maintaining diagnostic image quality

    Directory of Open Access Journals (Sweden)

    Hickethier T

    2018-05-01

    Full Text Available Tilman Hickethier,1,* Kamal Mammadov,1,* Bettina Baeßler,1 Thorsten Lichtenstein,1 Jochen Hinkelbein,2 Lucy Smith,3 Patrick Sven Plum,4 Seung-Hun Chon,4 David Maintz,1 De-Hua Chang1 1Department of Radiology, University Hospital of Cologne, Cologne, Germany; 2Department of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Cologne, Germany; 3Faculty of Medicine, Memorial University of Newfoundland, St. John’s, Canada; 4Department of General, Visceral and Cancer Surgery, University Hospital of Cologne, Cologne, Germany *These authors contributed equally to this work Background: The study was conducted to compare examination time and artifact vulnerability of whole-body computed tomographies (wbCTs for trauma patients using conventional or optimized patient positioning. Patients and methods: Examination time was measured in 100 patients scanned with conventional protocol (Group A: arms positioned alongside the body for head and neck imaging and over the head for trunk imaging and 100 patients scanned with optimized protocol (Group B: arms flexed on a chest pillow without repositioning. Additionally, influence of two different scanning protocols on image quality in the most relevant body regions was assessed by two blinded readers. Results: Total wbCT duration was about 35% or 3:46 min shorter in B than in A. Artifacts in aorta (27 vs 6%, liver (40 vs 8% and spleen (27 vs 5% occurred significantly more often in B than in A. No incident of non-diagnostic image quality was reported, and no significant differences for lungs and spine were found. Conclusion: An optimized wbCT positioning protocol for trauma patients allows a significant reduction of examination time while still maintaining diagnostic image quality. Keywords: CT scan, polytrauma, acute care, time requirement, positioning

  19. Novel route synthesis of porous and solid gold nanoparticles for investigating their comparative performance as contrast agent in computed tomography scan and effect on liver and kidney function.

    Science.gov (United States)

    Aziz, Farooq; Ihsan, Ayesha; Nazir, Aalia; Ahmad, Ishaq; Bajwa, Sadia Zafar; Rehman, Asma; Diallo, Abdoulaye; Khan, Waheed S

    2017-01-01

    Gold nanoparticles (GNPs) with dimension in the range of 1-100 nm have a prominent role in a number of biomedical applications like imaging, drug delivery, and cancer therapy owing to their unique optical features and biocompatibility. In this work, we report a novel technique for the synthesis of two types of GNPs namely porous gold nanoparticles (PGNPs) and solid gold nanoparticles (SGNPs). PGNPs of size 35 nm were fabricated by reduction of gold (III) solution with lecithin followed by addition of L-ascorbic acid and tri-sodium citrate, whereas SGNPs with a dimension of 28 nm were prepared by reflux method using lecithin as a single reducing agent. Comparative studies using PGNPs (λ max 560 nm) and SGNPs (λ max 548 nm) were conducted for evaluating their use as a contrast agent. These studies reveled that in direct computed tomography scan, PGNPs exhibited brighter contrast (45 HU) than SGNPs (26 HU). To investigate the effect of PGNPs and SGNPs on the liver and kidney profile, male rabbits were intravenously injected with an equal dose of 1 mg/kg weight of PGNPs and SGNPs. The effect on biochemical parameters was evaluated 72 hours after intravenous (IV) injection including liver function profile, renal (kidney) function biomarker, random blood glucose value, and cholesterol level. During one comparison of contrast in CT scan, PGNPs showed significantly enhanced contrast in whole-rabbit and organ CT scan as compared to SGNPs 6 hours after injection. Our findings suggested that the novel PGNPs enhance CT scan image with higher efficacy as compared to SGNPs. The results showed that IV administration of synthesized PGNPs increases the levels of aspartate aminotransferase (AST), alkaline phosphate (ALP), serum creatinine, and blood glucose, whereas that of SGNPs increases the levels of AST, ALP, and blood glucose.

  20. Findings on Thoracic Computed Tomography Scans and Respiratory Outcomes in Persons with and without Chronic Obstructive Pulmonary Disease: A Population-Based Cohort Study.

    Directory of Open Access Journals (Sweden)

    Wan C Tan

    Full Text Available Thoracic computed tomography (CT scans are widely performed in clinical practice, often leading to detection of airway or parenchymal abnormalities in asymptomatic or minimally symptomatic individuals. However, clinical relevance of CT abnormalities is uncertain in the general population.We evaluated data from 1361 participants aged ≥40 years from a Canadian prospective cohort comprising 408 healthy never-smokers, 502 healthy ever-smokers, and 451 individuals with spirometric evidence of chronic obstructive pulmonary disease (COPD who had thoracic CT scans. CT images of subjects were visually scored for respiratory bronchiolitis(RB, emphysema(E, bronchial-wall thickening(BWT, expiratory air-trapping(AT, and bronchiectasis(B. Multivariable logistic regression models were used to assess associations of CT features with respiratory symptoms, dyspnea, health status as determined by COPD assessment test, and risk of clinically significant exacerbations during 12 months follow-up.About 11% of life-time never-smokers demonstrated emphysema on CT scans. Prevalence increased to 30% among smokers with normal lung function and 36%, 50%, and 57% among individuals with mild, moderate or severe/very severe COPD, respectively. Presence of emphysema on CT was associated with chronic cough (OR,2.11; 95%CI,1.4-3.18; chronic phlegm production (OR,1.87; 95% CI,1.27-2.76; wheeze (OR,1.61; 95% CI,1.05-2.48; dyspnoea (OR,2.90; 95% CI,1.41-5.98; CAT score≥10(OR,2.17; 95%CI,1.42-3.30 and risk of ≥2 exacerbations over 12 months (OR,2.17; 95% CI, 1.42-3.0.Burden of thoracic CT abnormalities is high among Canadians ≥40 years of age, including never-smokers and smokers with normal lung function. Detection of emphysema on CT scans is associated with pulmonary symptoms and increased risk of exacerbations, independent of smoking or lung function.

  1. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  2. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  3. Intravenous Contrast Medium Administration for Computed Tomography Scan in Emergency: A Possible Cause of Contrast-Induced Nephropathy

    International Nuclear Information System (INIS)

    Sonhaye, Lantam; Kolou, Bérésa; Tchaou, Mazamaesso; Amadou, Abdoulatif; Assih, Kouméabalo; N'Timon, Bidamin; Adambounou, Kokou; Agoda-Koussema, Lama; Adjenou, Komlavi; N'Dakena, Koffi

    2015-01-01

    The goal of this study was to assess risk for CIN after CT Scan during an emergency and to identify risk factors for the patient. Prospective review of all patients admitted to the emergency room (ER) of the Teaching Hospital of Lomé (Togo) during a 2-year period. CIN was defined as an increase in serum creatinine by 0.5 mg/dL from admission after undergoing CT Scan with intravenous contrast. A total of 620 patients underwent a CT Scan in the emergency room using intravenous contrast and 672 patients took the CT Scan without intravenous contrast. Out of the patients who received intravenous contrast for CT Scan, three percent of them developed CIN during their admission. Moreover, upon discharge no patient had continued renal impairment. No patient required dialysis during their admission. The multivariate analysis of all patients who had serial creatinine levels (including those who did not receive any contrast load) shows no increased risk for acute kidney injury associated intravenous contrast (odds ratio = 0.619, p value = 0.886); only diabetes remains independent risk factor of acute kidney injury (odds ratio = 6.26, p value = 0.031)

  4. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  5. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  6. Computed Tomography Imaging of the Topographical Anatomy of Canine Prostate

    International Nuclear Information System (INIS)

    Dimtrox, R.; Yonkova, P.; Vladova, D.; Kostov, D.

    2010-01-01

    AIM: To investigate the topographical anatomy of canine prostate gland by computed tomography (CT) for diagnostic imaging purposes. ÐœATERIAL AND METHODS: Seven clinically healthy mongrel male dogs at the age of 3−4 years and body weight of 10−15 kg were submitted to transverse computerized axial tomography (CAT) with cross section thickness of 5 mm. RESULTS: The CT image of canine prostate is visualized throughout the scans of the pelvis in the planes through the first sacral vertebra (S1) dorsally; the bodies of iliac bones laterally and cranially to the pelvic brim (ventrally). The body of prostate appears as an oval homogenous relatively hypo dense finding with soft tissue density. The gland is well differentiated from the adjacent soft tissues. CONCLUSION: By means of CT, the cranial part of prostate gland in adult dogs aged 3−4 years exhibited an abdominal localization. (author)

  7. Computed tomography scanning can monitor the effects of soil medium on root system development: An example of salt stress in corn

    Directory of Open Access Journals (Sweden)

    Sowmyalakshmi eSubramanian

    2015-04-01

    Full Text Available Seeds and young seedlings often encounter high soluble salt levels in the upmost soil layers, impeding vigorous growth by affecting root establishment. Computed tomography (CT scanning used at low X-ray doses can help study root development in such conditions non-destructively, because plants are allowed to grow throughout the experiment. Using a high-resolution Toshiba XVision CT scanner, we studied corn (Zea mays L. root growth under optimal and salt-stressed conditions in 3D and on a weekly basis over 3 weeks. Two groups of 3 corn plants were grown in the controlled environment of a growth chamber, in mid-sized plastic pots filled with sieved and autoclaved sand. Seedlings were subjected to first CT scanning one week after seed planting. Our main research objectives concerning root systems were: (i to quantify structural complexity from fractal dimensions estimated on skeletal 3-D images built from CT scanning data; (ii to measure growth from volumes and derived relative rates, after isolating primary and secondary roots from the soil medium in CT scanning data; and (iii to assess differences in complexity and growth per week and over Weeks 1–3 for groups of corn plants. Differences between groups were present from Week 1; starting in Week 2 secondary roots were present and could be isolated, which refined the complexity and growth analyses of root systems. Besides expected Week main effects (P < 0.01 or 0.05, Week x Group interaction (P < 0.05 or 0.10 and Group main effects were observed, which is remarkable given the small sample sizes. Graphical, quantitative and statistical analyses of CT scanning data were thus completed at an unprecedented level, and provided new and important insights regarding root system development. Repeated CT scanning is the key to a better understanding of the establishment in the soil medium of crop plants such as corn and the assessment of salt stress effects on developing root systems, in complexity and

  8. Use of computed tomography scout film and Hounsfield unit of computed tomography scan in predicting the radio-opacity of urinary calculi in plain kidney, ureter and bladder radiographs.

    Science.gov (United States)

    Chua, Michael E; Gomez, Odina R; Sapno, Lorelei D; Lim, Steve L; Morales, Marcelino L

    2014-07-01

    The objective of this study is to determine the diagnostic utility of computed tomography (CT)- scout film with an optimal non-contrast helical CT scan Hounsfield unit (HU) in predicting the appearance of urinary calculus in the plain kidneys, ureter, urinary bladder (KUB)-radiograph. A prospective cross-sectional study was executed and data were collected from June 2007 to June 2012 at a tertiary hospital. The included subjects were diagnosed to have value, CT-scout film and KUB radiograph appearance were recorded independently by two observers. Univariate logistic analysis with receiver operating characteristic curve was generated to determine the best cut-off HU value of urolithiases not identified in CT-scout film, but determined radio-opaque in KUB X-ray. Subsequently, its sensitivity, specificity, predictive values and likelihood ratios were calculated. Statistical significance was set at P value of 0.05 or less. Two hundred and three valid cases were included. 73 out of 75 CT-scout film detected urolithiasis were identified on plain radiograph and determined as radio-opaque. The determined best cut off value of HU utilized for prediction of radiographic characteristics was 630HU at which urinary calculi were not seen at CT-scout film and were KUB X-ray radio-opaque. The set HU cut-off was established of ideal accuracy with an overall sensitivity of 82.2%, specificity of 96.9% and a positive predictive value of 96.5% and negative predictive value of 83.5%. Urolithiases identified on the CT-scout film were also seen as radiopaque on the KUB radiograph while those stones not visible on the CT-scout film, but above the optimal HU cut-off value of 630 are also likely to be radiopaque.

  9. Axial positrons emission tomography: from mouse to human brain imaging

    International Nuclear Information System (INIS)

    Brard, Emmanuel

    2013-01-01

    Positrons emission tomography is a nuclear imaging technics using nuclear decays. It is used both in clinical and preclinical studies. The later requires the use of small animals such as the mouse. The objective is to obtain the best signal with the best spatial resolution. Yet, a weight ratio between humans and mice indicates the need of a sub-millimeter resolution. A conventional scanner is based on detection modules surrounding the object to image and arranged perpendicularly. This implies a strong relationship between efficiency and spatial resolution. This work focuses on the axial geometry in which detection modules are arranged parallel to the object. This limits the relationship between the figures of merit, leading to both high spatial resolution and efficiency. The simulations of prototypes showed great perspectives in term of sub-millimeter resolution with efficiencies of 15 or 40% according to the scanner's axial extension. These results indicate great perspectives for both clinical and preclinical imaging. (author)

  10. Does the intensity of diffuse thyroid gland uptake on F-18 fluorodeoxyglucose positron emission tomography/computed tomography scan predict the severity of hypothyroidism? Correlation between maximal standardized uptake value and serum thyroid stimulating hormone levels

    International Nuclear Information System (INIS)

    Pruthi, Ankur; Choudhury, Partha Sarathi; Gupta, Manoj; Taywade, Sameer

    2015-01-01

    F-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography/computed tomography (PET/CT) scan and hypothyroidism. The aim was to determine whether the intensity of diffuse thyroid gland uptake on F-18 FDG PET/CT scans predicts the severity of hypothyroidism. A retrospective analysis of 3868 patients who underwent F-18 FDG PET/CT scans, between October 2012 and June 2013 in our institution for various oncological indications was done. Out of them, 106 (2.7%) patients (79 females, 27 males) presented with bilateral diffuse thyroid gland uptake as an incidental finding. These patients were investigated retrospectively and various parameters such as age, sex, primary cancer site, maximal standardized uptake value (SUVmax), results of thyroid function tests (TFTs) and fine-needle aspiration cytology results were noted. The SUVmax values were correlated with serum thyroid stimulating hormone (S. TSH) levels using Pearson's correlation analysis. Pearson's correlation analysis. Clinical information and TFT (serum FT3, FT4 and TSH levels) results were available for 31 of the 106 patients (27 females, 4 males; mean age 51.5 years). Twenty-six out of 31 patients (84%) were having abnormal TFTs with abnormal TSH levels in 24/31 patients (mean S. TSH: 22.35 μIU/ml, median: 7.37 μIU/ml, range: 0.074-211 μIU/ml). Among 7 patients with normal TSH levels, 2 patients demonstrated low FT3 and FT4 levels. No significant correlation was found between maximum standardized uptake value and TSH levels (r = 0.115, P > 0.05). Incidentally detected diffuse thyroid gland uptake on F-18 FDG PET/CT scan was usually associated with hypothyroidism probably caused by autoimmune thyroiditis. Patients should be investigated promptly irrespective of the intensity of FDG uptake with TFTs to initiate replacement therapy and a USG examination to look for any suspicious nodules

  11. Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations.

    Science.gov (United States)

    Shokri, Abbas; Eskandarloo, Amir; Norouzi, Marouf; Poorolajal, Jalal; Majidi, Gelareh; Aliyaly, Alireza

    2018-03-01

    This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

  12. Using 99mTc-DTPA radioaerosol inhalation lung scan as compared with computed tomography to detect lung injury in blunt chest trauma

    International Nuclear Information System (INIS)

    Esme, H.; Kaya, E.; Solak, O.; Yavuz, Y.; Yurumez, Y.; Sezer, M.

    2007-01-01

    Detection of pulmonary contusion in patients with blunt chest trauma is very important so as to commence therapy immediately to avoid irreversible damage. The purpose of our study was to evaluate the efficacy of technetium-99m diethylene triamine penta-acetic acid ( 99m Tc-DTPA) aerosol inhalation lung scintigraphy in comparison with chest computed tomography (CT) in the diagnosis of pulmonary contusion at acute blunt chest trauma. Twenty-nine patients with isolated blunt chest trauma were referred to the emergency department of our hospital, and nine healthy people participated in this study. Sixteen patients who had pulmonary contusion on CT scans were referred to as group 1, and 13 patients who had normal CT scans as group 2. Nine healthy people comprised a control group. 99m Tc-DTPA aerosol inhalation lung scintigraphy was performed on the first day in all patients. The mean half time (T 1/2 ) and penetration index values of 99m Tc-DTPA clearance were significantly lower in groups 1 and 2 compared with the control group. Among the three groups, there were no significant differences in arterial blood gas analysis except for PO 2 . The mean T 1/2 value of 99m Tc-DTPA clearance did correlate with PO 2 values but not with pH, PCO 2 , or HCO 3 values. 99m Tc-DTPA radioaerosol inhalation lung imaging may serve as a useful adjunct and supportive method to chest CT scanning for detecting mild pulmonary contusion. (author)

  13. The Incidence, Classification, and Management of Acute Adverse Reactions to the Low-Osmolar Iodinated Contrast Media Isovue and Ultravist in Contrast-Enhanced Computed Tomography Scanning.

    Science.gov (United States)

    Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing

    2016-03-01

    Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning.Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370.Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae.Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist-370 than with Isovue-370, but this difference is limited only to the mild AARs. The incidence of AARs could be affected by multiple factors.

  14. Computed tomography of liver tumors, 2. Differential diagnosis between hepatocellular carcinoma and metastatic hepatic tumor by dynamic CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Naito, Akira; Fukuoka, Haruhito; Kashiwado, Kouzou; Ichiki, Toshio; Makidono, Yoko [Hiroshima Red Cross Hospital (Japan)

    1984-02-01

    Differential diagnosis between hepatocellular carcinoma and metastatic hepatic tumor was attempted using dynamic CT scanning. Homogeneous and patchy types were peculiar to hepatocellular carcinoma, and ring-like type to metastatic hepatic tumor. However, with no enhancement, hepatocellular carcinoma could not be denied. Hepatocellular carcinoma was characterized by the enhancement shown on the early stage of dynamic CT. Ring enhancement was not visualized on dynamic CT but visualized on conventional contrast enhanced CT in hepatocellular carcinomas; it was visualized on conventional contrast enhanced CT and on dynamic CT in metastatic hepatic tumors.

  15. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  16. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  17. Detection of vertical root fractures in vivo in endodontically treated teeth by cone-beam computed tomography scans

    NARCIS (Netherlands)

    Metska, M.E.; Aartman, I.H.A.; Wesselink, P.R.; Özok, A.R.

    2012-01-01

    Introduction The presence of a vertical root fracture (VRF) in an endodontically treated tooth has an immense impact on the treatment’s outcome. Early diagnosis of a VRF is imperative to avoid overtreatment and extensive bone loss. Our study aimed to examine the validity of 2 cone-beam computed

  18. Novel route synthesis of porous and solid gold nanoparticles for investigating their comparative performance as contrast agent in computed tomography scan and effect on liver and kidney function

    Directory of Open Access Journals (Sweden)

    Aziz F

    2017-02-01

    Full Text Available Farooq Aziz,1,2 Ayesha Ihsan,1 Aalia Nazir,2 Ishaq Ahmad,3 Sadia Zafar Bajwa,1 Asma Rehman,1 Abdoulaye Diallo,4 Waheed S Khan1 1Nanobiotechnology Group, National Institute for Biotechnology and Genetic Engineering (NIBGE, Faisalabad, 2Department of Physics, Islamia University of Bahawalpur, Bahawalpur, 3National Center for Physics, Quaid-I-Azam University, Islamabad, Pakistan; 4Laboratory of Photonics and Nano-Fabrication, Faculty of Science and Technology, Cheikh Anta Diop University of Dakar (UCAD, Dakar-Fann Dakar, Senegal Abstract: Gold nanoparticles (GNPs with dimension in the range of 1–100 nm have a prominent role in a number of biomedical applications like imaging, drug delivery, and cancer therapy owing to their unique optical features and biocompatibility. In this work, we report a novel technique for the synthesis of two types of GNPs namely porous gold nanoparticles (PGNPs and solid gold nanoparticles (SGNPs. PGNPs of size 35 nm were fabricated by reduction of gold (III solution with lecithin followed by addition of L-ascorbic acid and tri-sodium citrate, whereas SGNPs with a dimension of 28 nm were prepared by reflux method using lecithin as a single reducing agent. Comparative studies using PGNPs (λmax 560 nm and SGNPs (λmax 548 nm were conducted for evaluating their use as a contrast agent. These studies reveled that in direct computed tomography scan, PGNPs exhibited brighter contrast (45 HU than SGNPs (26 HU. To investigate the effect of PGNPs and SGNPs on the liver and kidney profile, male rabbits were intravenously injected with an equal dose of 1 mg/kg weight of PGNPs and SGNPs. The effect on biochemical parameters was evaluated 72 hours after intravenous (IV injection including liver function profile, renal (kidney function biomarker, random blood glucose value, and cholesterol level. During one comparison of contrast in CT scan, PGNPs showed significantly enhanced contrast in whole-rabbit and organ CT scan as

  19. Comparison of planar scanning and single photon emission computed tomography in the diagnosis of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Feiglin, D.H.I.; Levine, M.; Stulberg, B.; Pflanze, W.; O'Donnell, J.K.; Belhobek, G.H.; Go, R.T.; MacIntyre, W.J.

    1986-01-01

    Thirty-nine patients were investigated for avascular necrosis of the femoral head. All hips were studied by plain x-ray and MR imaging, 70 hips studied by radionuclide bone scanning, and 38 were studied by single photon emission CT (SPECT). Core biopsies of the femoral heads from 32 hips were examined. No one reference standard for noninvasive diagnosis of this disease is available. The sensitivity and specificity of the radionuclide studies with respect to SPECT were 77% and 100%; of SPECT with respect to pathologic confirmation, 100% and 57%; of MR imaging with respect to pathologic studies, 100% and 66%. Pathologic sampling is subject to error and may give false negative results with spuriously low specificities for imaging modalities. SPECT is recommended as the radionuclide imaging procedure of choice for detecting avascular necrosis of the femoral head

  20. Role of whole body positron emission tomography/computed tomography scan with 18F-fluorodeoxyglucose in patients with biopsy proven tumor metastases from unknown primary site

    International Nuclear Information System (INIS)

    Pelosi, E.; Pennone, M.; Deandreis, D.; Bisi, G.

    2006-01-01

    Aim: The aim of this study was to evaluate the role of whole body PET/CT scan with 1 8F -fluorodeoxyglucose (FDG) in the detection of the primary tumor in patients with metastatic cancer from unknown primary origin (CUP syndrome). Methods: Sixty-eight consecutive patients, with CUP syndrome (39 lymph nodes, 29 visceral biopsy proven tumor metastases), underwent a whole-body FDG-PET/CT study. All enrolled patients were unsuccessfully studied, within the previous month, with physical examination, laboratory tests and conventional diagnostic procedures. All the pathological findings identified at PET/CT scan and suspected for primaries, were further investigated. After PET study, the minimum follow-up period for the inclusion in the studied population was 3 months. Results: The primary tumor site was correctly identified by FDG-PET/CT in 24 patients (24/68, 35.3%): long (0-9). rino/oro-pharynx (n=6), pancreas (n=5), colon (n=2). uterus (n=2). In 5 cases, FDG-PET scan did not identify a primary pathological focus, which was subsequently detected by other diagnostic methods within 3 months. In 39 patients (39168, 57.4%), the primary tumor site was not localized. However, in 9 of them, FDG-PET/CT scan identified further unexpected metastases, modifying the stage of disease. Overall, the following oncological treatment was influenced by the PET scan, in a total of 33 patients (33/68, 48.5%). Conclusion: Our data strongly support the diagnostic contribution of whole body FDG-PET/CT scan in the evaluation of patients with CUP syndrome and suggest its use in an early phase of the diagnostic iter to optimize patient management

  1. Comparison of three retreatment techniques with ultrasonic activation in flattened canals using micro-computed tomography and scanning electron microscopy.

    Science.gov (United States)

    Bernardes, R A; Duarte, M A H; Vivan, R R; Alcalde, M P; Vasconcelos, B C; Bramante, C M

    2015-08-17

    To use micro-CT to quantitatively evaluate the amount of residual filling material after using several techniques to remove root fillings with and without ultrasonic activation and to analyse the cleanliness of the root canal walls and dentine tubules with scanning electron microscopy (SEM). The root canals of one hundred and eight human mandibular incisors were selected and instrumented with rotary files using the BioRace system up to file size 40, .04 taper. After instrumentation, the teeth were filled using a hybrid technique with gutta-percha and sealer then divided into three groups according to the method used for removing the root filling: G1-Reciproc (using only instrument R50), G2-ProTaper Universal retreatment system and G3-Manual (hand files and Gates-Glidden burs). All groups were divided into two subgroups depending on whether ultrasonic agitation was used with the irrigants. Micro-CT scans were taken before and after removal of the filling material to detect residual material in the canal. After micro-CT analysis, the roots were cut in half, imaged by SEM and scored based on the amount of surface covered by root filling remnants. The data were analysed statistically using a significance level of 5%. All groups had retained material in the root canals after instrumentation. The Reciproc method was associated with less retained material than the ProTaper and Manual methods. Ultrasonic activation significantly reduced the amount of residual root filling in all groups (P material. Ultrasonic activation improved the removal of root filling material in all groups. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Computerized axial tomography of the chest for visualization of ''absent'' pulmonary arteries

    International Nuclear Information System (INIS)

    Sondheimer, H.M.; Oliphant, M.; Schneider, B.; Kavey, R.E.W.; Blackman, M.S.; Parker, F.B. Jr.

    1982-01-01

    To expand the search for central pulmonary arteries in six patients with absence of cardiac-pulmonary continuity, computerized axial tomography (CAT) of the chest was performed. The CAT scans were compared with previous arteriograms and pulmonary vein wedge angiograms. Three patients with type IV truncus arteriosus were studied, and none had a central, right or left pulmonary artery on CAT scan. However, two patients with tetralogy of Fallot with pulmonary atresia and a patent ductus arteriosus to the right lung demonstrated the presence of a left pulmonary artery. In addition, one child with truncus arteriosus with ''absent'' left pulmonary artery demonstrated a left pulmonary artery on the CAT scan. The CAT scan may therefore enhance our ability to search for disconnected pulmonary arteries in children with complex cyanotic congenital heart disease

  3. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  4. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  5. Computed Tomography Observer Agreement in Staging Malignant Lymphoma

    NARCIS (Netherlands)

    de Jong, Antoinette; Kwee, Thomas C.; Quarles van Ufford, Henriëtte M. E.; Beek, Frederik J. A.; Quekel, Lorentz G. B. A.; de Klerk, John M. H.; Zijlstra, Josée M.; Fijnheer, Rob; Ludwig, Inge; Kersten, Marie José; Stoker, Jaap; Nievelstein, Rutger A. J.

    2016-01-01

    To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann

  6. Computed tomography of cartilaginous tumours

    International Nuclear Information System (INIS)

    Marincek, B.; Triller, J.; Robotti, G.; Gumppenberg, S. von

    1984-01-01

    The compound tomography (CT) morphology of cartilaginous tumors and the utility of CT in their diagnostic work-up is presented on the basis of 19 cases. CT provided unique informations regarding definition of tumor extent and tumor relationship to adjacent structures particularly in the axial skeleton. CT has diminished the indications for angiography in cartilaginous tumors. (orig.) [de

  7. Prevalence of Protective Shielding Utilization for Radiation Dose Reduction in Adult Patients Undergoing Body Scanning Using Computed Tomography.

    Science.gov (United States)

    Safiullah, Shoaib; Patel, Roshan; Uribe, Brittany; Spradling, Kyle; Lall, Chandana; Zhang, Lishi; Okhunov, Zhamshid; Clayman, Ralph V; Landman, Jaime

    2017-10-01

    Ionizing radiation is implicated in nearly 2% of malignancies in the United States; radiation shields prevent unnecessary radiation exposure during medical imaging. Contemporary radiation shield utilization for adult patients in the United States is poorly defined. Therefore, we evaluated the prevalence of protective shielding utilization in adult patients undergoing CT scans in United States' hospitals. An online survey was sent to established radiology departments randomly selected from the 2015 American Hospital Association Guide. Radiology departments conducting adult CT imaging were eligible; among 370 eligible departments, 215 departments accepted the study participation request. Questions focused on shielding practices during CT imaging of the eyes, thyroid, breasts, and gonads. Prevalence data were stratified per hospital location, size, and type. Main outcomes included overall protective shielding utilization, respondents' belief and knowledge regarding radiation safety, and organ-specific shielding prevalence. Sixty-seven of 215 (31%) hospitals completed the survey; 66 (99%) reported familiarity with the ALARA (as low as reasonably achievable) principle and 56 (84%) affirmed their belief that shielding is beneficial. Only 60% of hospitals employed shielding during CT imaging; among these institutions, shielding varied based on CT study: abdominopelvic CT (13, 33%), head CT (33, 83%), or chest CT (30, 75%). Among surveyed hospitals, 40% do not utilize CT shielding despite the majority acknowledging the ALARA principle and agreeing that shielding is a beneficial practice. Failure to address the low prevalence of protective shielding may lead to poor community health due to increased risk of radiation-related cancers.

  8. Motion artifacts in computed tomography

    International Nuclear Information System (INIS)

    Yang, C.K.

    1979-01-01

    In the year 1972, the first Computed Tomography Scanner (or CT) was introduced and caused a revolution in the field of Diagnostic Radiology. A tomogram is a cross-sectional image of a three-dimensional object obtained through non-invasive measurements. The image that is presented is very similar to what would be seen if a thin cross-sectional slice of the patient was examined. In Computed Tomography, x-rays are passed through the body of a patient in many different directions and their attenuation is detected. By using some mathematical theorems, the attenuation information can be converted into the density of the patient along the x-ray path. Combined with modern sophisticated computer signal processing technology, a cross-sectional image can be generated and displayed on a TV monitor. Usually a good CT image relies on the patient not moving during the x-ray scanning. However, for some unconscious or severely ill patients, this is very difficult to achieve. Thus, the motion during the scan causes the so-called motion artifacts which distort the displayed image and sometimes these motion artifacts make diagnosis impossible. Today, to remove or avoid motion artifacts is one of the major efforts in developing new scanner systems. In this thesis, a better understanding of the motion artifacts problem in CT scaning is gained through computer simulations, real scanner experiments and theoretical analyses. The methods by which the distorted image can be improved are simulated also. In particular, it is assumed that perfect knowledge of the patient motion is known since this represents the theoretical limit on how well the distorted image can be improved

  9. Analysis of the Relation Between Exposure to Ionising Radiation from Computed Tomography Scans in Childhood and Cancer Incidence within the 'Cohorte Enfant Scanner' Study

    International Nuclear Information System (INIS)

    Journy, Neige

    2014-01-01

    Computed tomography (CT) is a powerful imaging technique that provides great benefits for diagnosis and medical management of patients. Nonetheless, the widespread use of this procedure raises many concerns about the potential adverse effects induced by X-rays exposure, both in clinical practice and in terms of public health. First epidemiological studies have suggested an increased risk of cancer associated with CT scan exposures in childhood or adolescence. The interpretation of these results is, however, controversial, and evidence about radiation-induced risks of cancer is still limited at this level of exposure and during childhood. In France, the 'Enfant Scanner' cohort was set up by IRSN to study the incidence of cancer among more than 100,000 children who received CT scans before the age of 10 in 21 university hospitals. This study is part of the European Epi-CT project - coordinated by the International Agency for Research on Cancer - which includes nine national cohorts set up on the basis of a common protocol. The current thesis, based on the French cohort, focuses on characterizing the exposure of children receiving diagnostic CT scans and quantifying the risk of cancer associated with these exposures. Dosimetric assessment was performed from the radiological protocols used in paediatrics between 2000 and 2011 in the participating hospitals. This study presents the evolution of the exposures during the period and the variability of practices in the radiology departments. The results show that there is a leeway for optimizing the procedures and limiting the exposure of patients, especially for scans of the head that account for most of the examinations in paediatrics. A quantitative assessment of cancer risk potentially induced by CT scans in paediatrics was performed - on the basis of estimates of risk in other contexts of ionizing radiation exposure. The results show that each CT scan could be associated with an excess risk of tumours of the

  10. In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography (CT) and Light Microscopy (LM) Correlated with Scanning Electron Microscopy (SEM).

    Science.gov (United States)

    Meyer, Jörg; Thomas, Christian; Tappe, Frank; Ogbazghi, Tekie

    2016-06-16

    In failure analysis, device characterization and reverse engineering of light emitting diodes (LEDs), and similar electronic components of micro-characterization, plays an important role. Commonly, different techniques like X-ray computed tomography (CT), light microscopy (LM) and scanning electron microscopy (SEM) are used separately. Similarly, the results have to be treated for each technique independently. Here a comprehensive study is shown which demonstrates the potentials leveraged by linking CT, LM and SEM. In depth characterization is performed on a white emitting LED, which can be operated throughout all characterization steps. Major advantages are: planned preparation of defined cross sections, correlation of optical properties to structural and compositional information, as well as reliable identification of different functional regions. This results from the breadth of information available from identical regions of interest (ROIs): polarization contrast, bright and dark-field LM images, as well as optical images of the LED cross section in operation. This is supplemented by SEM imaging techniques and micro-analysis using energy dispersive X-ray spectroscopy.

  11. Multi-scale characteristics of coal structure by x-ray computed tomography (x-ray CT), scanning electron microscope (SEM) and mercury intrusion porosimetry (MIP)

    Science.gov (United States)

    Cai, Ting-ting; Feng, Zeng-chao; Zhou, Dong

    2018-02-01

    It is of great benefit to study the material and structural heterogeneity of coal for better understanding the coalbed methane (CBM) storage and enrichment. In this paper, multi-scale X-ray computed tomography (CT), scanning electron microscope (SEM) and mercury intrusion porosimetry (MIP) at multi scales were conducted to thoroughly study the material distribution, heterogeneity, pore development, porosity and permeability of coal. It is suitable and reasonable to divide the testing samples into three structural categories by average density and heterogeneity degree, and the meso structure in the three categories accords with the morphology on SEM images. The pore size distribution and pore development of each subsample cannot be correspondingly related to their respective structure category or morphology due to different observation scales, while the macro pore size development, accumulated macro pore volume and macro pores porosity accord with the meso structure category and morphology information by CT and SEM at the same scale very well. Given the effect of macro pores on permeability and the contribution of micro pores to CBM storage capacity, reservoirs with developed micro pores and macro pores may be the most suitable coal reservoir for CBM exploitation.

  12. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  13. Crown traits of coniferous trees and their relation to shade tolerance can differ with leaf type: a biophysical demonstration using computed tomography scanning data.

    Science.gov (United States)

    Dutilleul, Pierre; Han, Liwen; Valladares, Fernando; Messier, Christian

    2015-01-01

    Plant light interception and shade tolerance are intrinsically related in that they involve structural, morphological and physiological adaptations to manage light capture for photosynthetic utilization, in order to sustain survival, development and reproduction. At the scale of small-size trees, crown traits related to structural geometry of branching pattern and space occupancy through phyllotaxis can be accurately evaluated in 3D, using computed tomography (CT) scanning data. We demonstrate this by scrutinizing the crowns of 15 potted miniature conifers of different species or varieties, classified in two groups based on leaf type (10 needlelike, 5 scalelike); we also test whether mean values of crown traits measured from CT scanning data and correlations with a shade tolerance index (STI) differ between groups. Seven crown traits, including fractal dimensions (FD1: smaller scales, FD2: larger scales) and leaf areas, were evaluated for all 15 miniature conifers; an average silhouette-to-total-area ratio was also calculated for each of the 10 needlelike-leaf conifers. Between-group differences in mean values are significant (P conifers with scalelike leaves, which had lower STI and higher FD1 on average in our study; the positive correlation between STI and ĀD is significant (P < 0.05) for the scalelike-leaf group, and very moderate for the needlelike-leaf one. A contrasting physical attachment of the leaves to branches may explain part of the between-group differences. Our findings open new avenues for the understanding of fundamental plant growth processes; the information gained could be included in a multi-scale approach to tree crown modeling.

  14. Magnetic Resonance–Based Automatic Air Segmentation for Generation of Synthetic Computed Tomography Scans in the Head Region

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Weili; Kim, Joshua P. [Department of Radiation Oncology, Henry Ford Health Systems, Detroit, Michigan (United States); Kadbi, Mo [Philips Healthcare, Cleveland, Ohio (United States); Movsas, Benjamin; Chetty, Indrin J. [Department of Radiation Oncology, Henry Ford Health Systems, Detroit, Michigan (United States); Glide-Hurst, Carri K., E-mail: churst2@hfhs.org [Department of Radiation Oncology, Henry Ford Health Systems, Detroit, Michigan (United States)

    2015-11-01

    Purpose: To incorporate a novel imaging sequence for robust air and tissue segmentation using ultrashort echo time (UTE) phase images and to implement an innovative synthetic CT (synCT) solution as a first step toward MR-only radiation therapy treatment planning for brain cancer. Methods and Materials: Ten brain cancer patients were scanned with a UTE/Dixon sequence and other clinical sequences on a 1.0 T open magnet with simulation capabilities. Bone-enhanced images were generated from a weighted combination of water/fat maps derived from Dixon images and inverted UTE images. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating segmentation errors (true-positive rate, false-positive rate, and Dice similarity indices using CT simulation (CT-SIM) as ground truth. The synCTs were generated using a voxel-based, weighted summation method incorporating T2, fluid attenuated inversion recovery (FLAIR), UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized Hounsfield unit (HU) differences between synCT and CT-SIM. A dosimetry study was conducted, and differences were quantified using γ-analysis and dose-volume histogram analysis. Results: On average, true-positive rate and false-positive rate for the CT and MR-derived air masks were 80.8% ± 5.5% and 25.7% ± 6.9%, respectively. Dice similarity indices values were 0.78 ± 0.04 (range, 0.70-0.83). Full field of view MAE between synCT and CT-SIM was 147.5 ± 8.3 HU (range, 138.3-166.2 HU), with the largest errors occurring at bone–air interfaces (MAE 422.5 ± 33.4 HU for bone and 294.53 ± 90.56 HU for air). Gamma analysis revealed pass rates of 99.4% ± 0.04%, with acceptable treatment plan quality for the cohort. Conclusions: A hybrid MRI phase/magnitude UTE image processing technique was introduced that significantly improved bone and air contrast in MRI. Segmented air masks and bone-enhanced images were integrated

  15. Magnetic Resonance–Based Automatic Air Segmentation for Generation of Synthetic Computed Tomography Scans in the Head Region

    International Nuclear Information System (INIS)

    Zheng, Weili; Kim, Joshua P.; Kadbi, Mo; Movsas, Benjamin; Chetty, Indrin J.; Glide-Hurst, Carri K.

    2015-01-01

    Purpose: To incorporate a novel imaging sequence for robust air and tissue segmentation using ultrashort echo time (UTE) phase images and to implement an innovative synthetic CT (synCT) solution as a first step toward MR-only radiation therapy treatment planning for brain cancer. Methods and Materials: Ten brain cancer patients were scanned with a UTE/Dixon sequence and other clinical sequences on a 1.0 T open magnet with simulation capabilities. Bone-enhanced images were generated from a weighted combination of water/fat maps derived from Dixon images and inverted UTE images. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating segmentation errors (true-positive rate, false-positive rate, and Dice similarity indices using CT simulation (CT-SIM) as ground truth. The synCTs were generated using a voxel-based, weighted summation method incorporating T2, fluid attenuated inversion recovery (FLAIR), UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized Hounsfield unit (HU) differences between synCT and CT-SIM. A dosimetry study was conducted, and differences were quantified using γ-analysis and dose-volume histogram analysis. Results: On average, true-positive rate and false-positive rate for the CT and MR-derived air masks were 80.8% ± 5.5% and 25.7% ± 6.9%, respectively. Dice similarity indices values were 0.78 ± 0.04 (range, 0.70-0.83). Full field of view MAE between synCT and CT-SIM was 147.5 ± 8.3 HU (range, 138.3-166.2 HU), with the largest errors occurring at bone–air interfaces (MAE 422.5 ± 33.4 HU for bone and 294.53 ± 90.56 HU for air). Gamma analysis revealed pass rates of 99.4% ± 0.04%, with acceptable treatment plan quality for the cohort. Conclusions: A hybrid MRI phase/magnitude UTE image processing technique was introduced that significantly improved bone and air contrast in MRI. Segmented air masks and bone-enhanced images were integrated

  16. A quantitative evaluation of pleural effusion on computed tomography scans using B-spline and local clustering level set.

    Science.gov (United States)

    Song, Lei; Gao, Jungang; Wang, Sheng; Hu, Huasi; Guo, Youmin

    2017-01-01

    Estimation of the pleural effusion's volume is an important clinical issue. The existing methods cannot assess it accurately when there is large volume of liquid in the pleural cavity and/or the patient has some other disease (e.g. pneumonia). In order to help solve this issue, the objective of this study is to develop and test a novel algorithm using B-spline and local clustering level set method jointly, namely BLL. The BLL algorithm was applied to a dataset involving 27 pleural effusions detected on chest CT examination of 18 adult patients with the presence of free pleural effusion. Study results showed that average volumes of pleural effusion computed using the BLL algorithm and assessed manually by the physicians were 586 ml±339 ml and 604±352 ml, respectively. For the same patient, the volume of the pleural effusion, segmented semi-automatically, was 101.8% ±4.6% of that was segmented manually. Dice similarity was found to be 0.917±0.031. The study demonstrated feasibility of applying the new BLL algorithm to accurately measure the volume of pleural effusion.

  17. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  18. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  19. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  20. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  1. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  2. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal

  3. Individualized Nonadaptive and Online-Adaptive Intensity-Modulated Radiotherapy Treatment Strategies for Cervical Cancer Patients Based on Pretreatment Acquired Variable Bladder Filling Computed Tomography Scans

    International Nuclear Information System (INIS)

    Bondar, M.L.; Hoogeman, M.S.; Mens, J.W.; Quint, S.; Ahmad, R.; Dhawtal, G.; Heijmen, B.J.

    2012-01-01

    Purpose: To design and evaluate individualized nonadaptive and online-adaptive strategies based on a pretreatment established motion model for the highly deformable target volume in cervical cancer patients. Methods and Materials: For 14 patients, nine to ten variable bladder filling computed tomography (CT) scans were acquired at pretreatment and after 40 Gy. Individualized model-based internal target volumes (mbITVs) accounting for the cervix and uterus motion due to bladder volume changes were generated by using a motion-model constructed from two pretreatment CT scans (full and empty bladder). Two individualized strategies were designed: a nonadaptive strategy, using an mbITV accounting for the full-range of bladder volume changes throughout the treatment; and an online-adaptive strategy, using mbITVs of bladder volume subranges to construct a library of plans. The latter adapts the treatment online by selecting the plan-of-the-day from the library based on the measured bladder volume. The individualized strategies were evaluated by the seven to eight CT scans not used for mbITVs construction, and compared with a population-based approach. Geometric uniform margins around planning cervix–uterus and mbITVs were determined to ensure adequate coverage. For each strategy, the percentage of the cervix–uterus, bladder, and rectum volumes inside the planning target volume (PTV), and the clinical target volume (CTV)-to-PTV volume (volume difference between PTV and CTV) were calculated. Results: The margin for the population-based approach was 38 mm and for the individualized strategies was 7 to 10 mm. Compared with the population-based approach, the individualized nonadaptive strategy decreased the CTV-to-PTV volume by 48% ± 6% and the percentage of bladder and rectum inside the PTV by 5% to 45% and 26% to 74% (p < 0.001), respectively. Replacing the individualized nonadaptive strategy by an online-adaptive, two-plan library further decreased the percentage of

  4. Cardiac dosimetric evaluation of deep inspiration breath-hold level variances using computed tomography scans generated from deformable image registration displacement vectors

    International Nuclear Information System (INIS)

    Harry, Taylor; Rahn, Doug; Semenov, Denis; Gu, Xuejun; Yashar, Catheryn; Einck, John; Jiang, Steve; Cerviño, Laura

    2016-01-01

    There is a reduction in cardiac dose for left-sided breast radiotherapy during treatment with deep inspiration breath-hold (DIBH) when compared with treatment with free breathing (FB). Various levels of DIBH may occur for different treatment fractions. Dosimetric effects due to this and other motions are a major component of uncertainty in radiotherapy in this setting. Recent developments in deformable registration techniques allow displacement vectors between various temporal and spatial patient representations to be digitally quantified. We propose a method to evaluate the dosimetric effect to the heart from variable reproducibility of DIBH by using deformable registration to create new anatomical computed tomography (CT) scans. From deformable registration, 3-dimensional deformation vectors are generated with FB and DIBH. The obtained deformation vectors are scaled to 75%, 90%, and 110% and are applied to the reference image to create new CT scans at these inspirational levels. The scans are then imported into the treatment planning system and dose calculations are performed. The average mean dose to the heart was 2.5 Gy (0.7 to 9.6 Gy) at FB, 1.2 Gy (0.6 to 3.8 Gy, p < 0.001) at 75% inspiration, 1.1 Gy (0.6 to 3.1 Gy, p = 0.004) at 90% inspiration, 1.0 Gy (0.6 to 3.0 Gy) at 100% inspiration or DIBH, and 1.0 Gy (0.6 to 2.8 Gy, p = 0.019) at 110% inspiration. The average mean dose to the left anterior descending artery (LAD) was 19.9 Gy (2.4 to 46.4 Gy), 8.6 Gy (2.0 to 43.8 Gy, p < 0.001), 7.2 Gy (1.9 to 40.1 Gy, p = 0.035), 6.5 Gy (1.8 to 34.7 Gy), and 5.3 Gy (1.5 to 31.5 Gy, p < 0.001), correspondingly. This novel method enables numerous anatomical situations to be mimicked and quantifies the dosimetric effect they have on a treatment plan.

  5. Cardiac dosimetric evaluation of deep inspiration breath-hold level variances using computed tomography scans generated from deformable image registration displacement vectors

    Energy Technology Data Exchange (ETDEWEB)

    Harry, Taylor [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA (United States); Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, OR (United States); Rahn, Doug; Semenov, Denis [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA (United States); Gu, Xuejun [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Yashar, Catheryn; Einck, John [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA (United States); Jiang, Steve [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Cerviño, Laura, E-mail: lcervino@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA (United States)

    2016-04-01

    There is a reduction in cardiac dose for left-sided breast radiotherapy during treatment with deep inspiration breath-hold (DIBH) when compared with treatment with free breathing (FB). Various levels of DIBH may occur for different treatment fractions. Dosimetric effects due to this and other motions are a major component of uncertainty in radiotherapy in this setting. Recent developments in deformable registration techniques allow displacement vectors between various temporal and spatial patient representations to be digitally quantified. We propose a method to evaluate the dosimetric effect to the heart from variable reproducibility of DIBH by using deformable registration to create new anatomical computed tomography (CT) scans. From deformable registration, 3-dimensional deformation vectors are generated with FB and DIBH. The obtained deformation vectors are scaled to 75%, 90%, and 110% and are applied to the reference image to create new CT scans at these inspirational levels. The scans are then imported into the treatment planning system and dose calculations are performed. The average mean dose to the heart was 2.5 Gy (0.7 to 9.6 Gy) at FB, 1.2 Gy (0.6 to 3.8 Gy, p < 0.001) at 75% inspiration, 1.1 Gy (0.6 to 3.1 Gy, p = 0.004) at 90% inspiration, 1.0 Gy (0.6 to 3.0 Gy) at 100% inspiration or DIBH, and 1.0 Gy (0.6 to 2.8 Gy, p = 0.019) at 110% inspiration. The average mean dose to the left anterior descending artery (LAD) was 19.9 Gy (2.4 to 46.4 Gy), 8.6 Gy (2.0 to 43.8 Gy, p < 0.001), 7.2 Gy (1.9 to 40.1 Gy, p = 0.035), 6.5 Gy (1.8 to 34.7 Gy), and 5.3 Gy (1.5 to 31.5 Gy, p < 0.001), correspondingly. This novel method enables numerous anatomical situations to be mimicked and quantifies the dosimetric effect they have on a treatment plan.

  6. Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images

    Science.gov (United States)

    Antony, Bhavna; Abràmoff, Michael D.; Tang, Li; Ramdas, Wishal D.; Vingerling, Johannes R.; Jansonius, Nomdo M.; Lee, Kyungmoo; Kwon, Young H.; Sonka, Milan; Garvin, Mona K.

    2011-01-01

    The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y axes. In this paper, we propose a novel technique that uses thin-plate splines in two stages to estimate and correct the distinct axial artifacts in SD-OCT images. The method was quantitatively validated using nine pairs of OCT scans obtained with orthogonal fast-scanning axes, where a segmented surface was compared after both datasets had been corrected. The mean unsigned difference computed between the locations of this artifact-corrected surface after the single-spline and dual-spline correction was 23.36 ± 4.04 μm and 5.94 ± 1.09 μm, respectively, and showed a significant difference (p < 0.001 from two-tailed paired t-test). The method was also validated using depth maps constructed from stereo fundus photographs of the optic nerve head, which were compared to the flattened top surface from the OCT datasets. Significant differences (p < 0.001) were noted between the artifact-corrected datasets and the original datasets, where the mean unsigned differences computed over 30 optic-nerve-head-centered scans (in normalized units) were 0.134 ± 0.035 and 0.302 ± 0.134, respectively. PMID:21833377

  7. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  8. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  9. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  10. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    International Nuclear Information System (INIS)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F.

    2015-01-01

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length

  11. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length.

    Science.gov (United States)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F

    2015-09-01

    Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as -0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31 μl/min among four wild-type rats. The authors' measured flow rates were consistent with results in the literature. By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  12. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Jiao, Shuliang [Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States); Zhang, Hao F., E-mail: hfzhang@northwestern.edu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611 (United States)

    2015-09-15

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  13. Computed tomography of epileptic children

    International Nuclear Information System (INIS)

    Kurihara, Mana; Yamashita, Sumimasa; Miyake, Shota; Yamada, Michiko; Iwamoto, Hiroko

    1986-01-01

    The aim of this study was to analyze the changes seen on cranial computed tomography (CT) of epileptic children, especially in the area of the temporal horn. The subjects were 242 epileptic children excluding those with encephalitis, brain tumor, neurocutaneous syndromes, degenerative disease, hydrocephalus etc. The control subjects were 195 children without any neurological disease and symptoms. CT scan were taken with a TCT-60A whole body scanner, and 14 check points were evaluated excluding the temporal horn. 195 epileptic children (N-group) and all control children were normal at 14 check points. Next, the areas of the temporal horns and adjoining hemispheres of the epileptic children (N-group) and control children were examined with Muto-Tablet-Desitizer. The temporal horn ratio ((area of temporal horn/area of ipsilateral hemisphere) x 100) was greater in younger children of the control group, and it was higher in epileptic than in control children. Enlargement of the temporal horn was seen in 1 % of the controls and in 35 % of the 125 epileptic children with normal measurements at 14 points on CT scans (p < 0.01). The frequency of enlargement of temporal horns was not variable among different epileptic types. In the epileptic children with normal CT scans except for enlargement of temporal horns behavioral disturbances were 6 boys and 5 had enlarged temporal horns (bilateral 1 case, left side 1 case, right side 3 cases). (author)

  14. Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study

    NARCIS (Netherlands)

    Boomsma, Martijn F.; Warringa, Niek; Edens, Mireille A.; Mueller, Dirk; Ettema, Harmen B.; Verheyen, Cees C. P. M.; Maas, Mario

    2016-01-01

    Purpose: Quantification of the effect of O-MAR on decreasing metal artefacts caused by large head metal on metal total hip arthroplasty (MoM THA) in a dedicated phantom setup of the hip. Background: Pathological reactions of the hip capsule on Computed tomography (CT) can be difficult to diagnose

  15. The use of a wax bite wafer and a double computed tomography scan procedure to obtain a three-dimensional augmented virtual skull model.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mommaerts, M.Y.; Abeloos, J.V.S.; Clercq, C. De; Lamoral, P.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2007-01-01

    A detailed visualization of the interocclusal relationship is essential in a three-dimensional virtual planning setup for orthognathic and facial orthomorphic surgery. The purpose of this study was to introduce and evaluate the use of a wax bite wafer in combination with a double computed tomography

  16. 128-slice Dual-source Computed Tomography Coronary Angiography in Patients with Atrial Fibrillation: Image Quality and Radiation Dose of Prospectively Electrocardiogram-triggered Sequential Scan Compared with Retrospectively Electrocardiogram-gated Spiral Scan.

    Science.gov (United States)

    Lin, Lu; Wang, Yi-Ning; Kong, Ling-Yan; Jin, Zheng-Yu; Lu, Guang-Ming; Zhang, Zhao-Qi; Cao, Jian; Li, Shuo; Song, Lan; Wang, Zhi-Wei; Zhou, Kang; Wang, Ming

    2013-01-01

    Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequential scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrillation referred for a second-generation 128-slice DSCT coronary angiography were included in the prospective study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG-triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel-lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each patient were compared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean HR (t=1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by reader1 and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by reader1 and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27±0.19 vs. 1.25±0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively

  17. Prospective Comparison of F-18 Choline PET/CT Scan Versus Axial MRI for Detecting Bone Metastasis in Biochemically Relapsed Prostate Cancer Patients

    Directory of Open Access Journals (Sweden)

    Wouter Huysse

    2017-10-01

    Full Text Available We compared fluor-18 choline positron emission tomography/computed tomography (PET/CT and axial skeleton magnetic resonance imaging (MRI prospectively obtained for the detection of bone metastases in non-castrated patients with biochemically recurrent prostate cancer following primary treatment. PET/CT was performed 45 min post-injection of 3–4 MBq/kg F-18 methyl choline. MRI included T1- and fluid sensitive T2-weighted images of the spine and pelvis. Readers were initially blinded from other results and all scans underwent independent double reading. The best valuable comparator (BVC defined the metastatic status. On the basis of the BVC, 15 out of 64 patients presented with 24 bone metastases. On a patient level, the sensitivity and specificity of MRI and PET were not significantly different. On a lesion level, the sensitivity of MRI was significantly better compared to PET, and the specificity did not differ significantly. In conclusion, axial MRI is an interesting screening tool for the detection of bone metastases because of its low probability of false negative results. However, F-18 choline PET is a valuable addition as it can overrule false positive MRI results and detect non-axial metastases.

  18. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  19. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Shapiro, Michael D.; Pena, Antonio J.; Nichols, John H.; Worrell, Stewart; Bamberg, Fabian; Dannemann, Nina; Abbara, Suhny; Cury, Ricardo C.; Brady, Thomas J.; Hoffmann, Udo

    2008-01-01

    Objective: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort. Methods: We studied 150 consecutive patients (104 men/46 female; mean age, 56 ± 13 years) referred for coronary CTA. Intravenous metoprolol (5-20 mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm. Results: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12 ± 10 mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p = 0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR. Conclusion: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration

  20. Four-dimensional measurement of the displacement of internal fiducial and skin markers during 320-multislice computed tomography scanning of breast cancer.

    Science.gov (United States)

    Yamashita, Hideomi; Okuma, Kae; Tada, Keiichiro; Shiraishi, Kenshiro; Takahashi, Wataru; Shibata-Mobayashi, Shino; Sakumi, Akira; Saotome, Naoya; Haga, Akihiro; Onoe, Tsuyoshi; Ino, Kenji; Akahane, Masaaki; Ohtomo, Kuni; Nakagawa, Keiichi

    2012-10-01

    To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients. Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 ± 0.3 mm, 2.1 ± 0.6 mm, and 1.6 ± 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 ± 0.2 mm in left-right, 1.7 ± 0.5 mm in A/P, and 1.1 ± 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions. Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    International Nuclear Information System (INIS)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M.

    1989-01-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction

  2. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Michael D. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Pena, Antonio J.; Nichols, John H. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Worrell, Stewart [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Bamberg, Fabian [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Dannemann, Nina [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Abbara, Suhny; Cury, Ricardo C.; Brady, Thomas J. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Hoffmann, Udo [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States)], E-mail: uhoffmann@partners.org

    2008-04-15

    Objective: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort. Methods: We studied 150 consecutive patients (104 men/46 female; mean age, 56 {+-} 13 years) referred for coronary CTA. Intravenous metoprolol (5-20 mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm. Results: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12 {+-} 10 mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p = 0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR. Conclusion: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration.

  3. Rheumatoid arthritis-associated interstitial lung disease: lung inflammation evaluated with high resolution computed tomography scan is correlated to rheumatoid arthritis disease activity.

    Science.gov (United States)

    Pérez-Dórame, Renzo; Mejía, Mayra; Mateos-Toledo, Heidegger; Rojas-Serrano, Jorge

    2015-01-01

    To describe the association between rheumatoid arthritis disease activity (RA) and interstitial lung damage (inflammation and fibrosis), in a group of patients with rheumatoid arthritis-associated interstitial lung disease (RA-ILD). A retrospective study of RA patients with interstitial lung disease (restrictive pattern in lung function tests and evidence of interstitial lung disease in high resolution computed tomography (HRCT)). Patients were evaluated to exclude other causes of pulmonary disease. RA disease activity was measured with the CDAI index. Interstitial lung inflammation and fibrosis were determined by Kazerooni scale. We compared Kazerooni ground-glass score with the nearest CDAI score to HRCT date scan of the first medical evaluation at our institution. In nine patients, we compared the first ground-glass score with a second one after treatment with DMARDs and corticosteroids. Spearman's rank correlation coefficient was used to evaluate association between RA disease activity and the Kazerooni ground-glass and fibrosis scores. Thirty-four patients were included. A positive correlation between CDAI and ground-glass scores was found (rs=0.3767, P<0.028). Fibrosis and CDAI scores were not associated (rs=-0.0747, P<0.6745). After treatment, a downward tendency in the ground-glass score was observed (median [IQR]): (2.33 [2,3] vs. 2 [1.33-2.16]), P<0.056, along with a lesser CDAI score (27 [8-43] vs. 9 [5-12]), P<0.063. There is a correlation between RA disease activity and ground-glass appearance in the HRCT of RA-ILD patients. These results suggest a positive association between RA disease activity and lung inflammation in RA-ILD. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  4. Interpretation of computed tomography imaging of the eye and orbit. A systematic approach

    Directory of Open Access Journals (Sweden)

    Naik Milind

    2002-01-01

    Full Text Available Computed tomography (CT has revolutionised the diagnosis and management of ocular and orbital diseases. The use of thin sections with multiplanar scanning (axial, coronal and sagittal planes and the possibility of three-dimensional reconstruction permits thorough evaluation. To make the most of this technique, users must familiarize themselves with the pertinent CT principles and terminology. The diagnostic yield is optimal when the ophthalmologist and radiologist collaborate in the radiodiagnostic workup. In this article we describe a systematic approach to the interpretation of ocular and orbital CT scans.

  5. Crown traits of coniferous trees and their relation to shade tolerance can differ with leaf type: a biophysical demonstration using computed tomography scanning data

    Science.gov (United States)

    Dutilleul, Pierre; Han, Liwen; Valladares, Fernando; Messier, Christian

    2015-01-01

    Plant light interception and shade tolerance are intrinsically related in that they involve structural, morphological and physiological adaptations to manage light capture for photosynthetic utilization, in order to sustain survival, development and reproduction. At the scale of small-size trees, crown traits related to structural geometry of branching pattern and space occupancy through phyllotaxis can be accurately evaluated in 3D, using computed tomography (CT) scanning data. We demonstrate this by scrutinizing the crowns of 15 potted miniature conifers of different species or varieties, classified in two groups based on leaf type (10 needlelike, 5 scalelike); we also test whether mean values of crown traits measured from CT scanning data and correlations with a shade tolerance index (STI) differ between groups. Seven crown traits, including fractal dimensions (FD1: smaller scales, FD2: larger scales) and leaf areas, were evaluated for all 15 miniature conifers; an average silhouette-to-total-area ratio was also calculated for each of the 10 needlelike-leaf conifers. Between-group differences in mean values are significant (P < 0.05) for STI, FD1, FD2, and the average leaf area displayed (ĀD). Between-group differences in sign and strength of correlations are observed. For example, the correlation between STI and FD1 is negative and significant (P < 0.10) for the needlelike-leaf group, but is positive and significant (P < 0.05) for the miniature conifers with scalelike leaves, which had lower STI and higher FD1 on average in our study; the positive correlation between STI and ĀD is significant (P < 0.05) for the scalelike-leaf group, and very moderate for the needlelike-leaf one. A contrasting physical attachment of the leaves to branches may explain part of the between-group differences. Our findings open new avenues for the understanding of fundamental plant growth processes; the information gained could be included in a multi-scale approach to tree crown

  6. Crown traits of coniferous trees and their relation to shade tolerance can differ with leaf type: A biophysical demonstration using computed tomography scanning data

    Directory of Open Access Journals (Sweden)

    Pierre eDutilleul

    2015-03-01

    Full Text Available Plant light interception and shade tolerance are intrinsically related in that they involve structural, morphological and physiological adaptations to manage light capture for photosynthetic utilization, in order to sustain survival, development and reproduction. At the scale of small-size trees, crown traits related to structural geometry of branching pattern and space occupancy through phyllotaxis can be accurately evaluated in 3D, using computed tomography (CT scanning data. We demonstrate this by scrutinizing the crowns of 15 potted miniature conifers of different species or varieties, classified in two groups based on leaf type (10 needlelike, 5 scalelike; we also test whether mean values of crown traits measured from CT scanning data and correlations with a shade tolerance index (STI differ between groups. Seven crown traits, including fractal dimensions (FD1: smaller scales, FD2: larger scales and leaf areas, were evaluated for all 15 miniature conifers; an average silhouette-to-total-area ratio was also calculated for each of the 10 needlelike-leaf conifers. Between-group differences in mean values are significant (P < 0.05 for STI, FD1, FD2, and average leaf area displayed (A_D. Between-group differences in sign and strength of correlations are observed. For example, the correlation between STI and FD1 is negative and significant (P < 0.10 for the needlelike-leaf group, but is positive and significant (P < 0.05 for the miniature conifers with scalelike leaves, which had lower STI and higher FD1 on average in our study; the positive correlation between STI and A_D is significant (P < 0.05 for the scalelike-leaf group, and very moderate for the needlelike-leaf one. A contrasting physical attachment of leaves to branches may explain part of the between-group differences. Our findings open new avenues for the understanding of fundamental plant growth processes; the information gained could be included in a multi-scale approach to tree crown

  7. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  8. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  9. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  10. A comparative study of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and 99mTc-MDP whole-body bone scanning for imaging osteolytic bone metastases

    International Nuclear Information System (INIS)

    Zhang, Lin; Chen, Lihua; Xie, Qiao; Zhang, Yongke; Cheng, Lin; Li, Haitao; Wang, Jian

    2015-01-01

    The objective of this study was to evaluate the feasibility and diagnostic value of 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and 99m Tc-methylenediphosphonate (MDP) whole-body bone scanning (BS) for the detection of osteolytic bone metastases. Thirty-four patients with pathologically confirmed malignancies and suspected osteolytic bone metastases underwent 18 F-FDG PET/CT and 99m Tc-MDP whole-body BS within 30 days. The sensitivity, specificity, and accuracy with respect to the diagnosis of osteolytic bone metastases and bone lesions were compared between the two imaging methods. The sensitivity, specificity, and accuracy of 18 F-FDG PET/CT for the diagnosis of osteolytic bone metastases were 94.3% (95% confidence interval [CI], 91.6–96.2%), 83.3% (95% CI, 43.6–96.9%), and 94.2% (95% CI, 91.5–96.1%), respectively. It was found that 99m Tc-MDP whole-body BS could discriminate between patients with 50.2% (95% CI, 45.4–55.1%) sensitivity, 50.0% (95% CI, 18.8–81.2%) specificity, and 50.2% (95% CI, 45.5–55.1%) accuracy. 18 F-FDG PET/CT achieved higher sensitivity, specificity, and accuracy in detecting osteolytic bone metastases than 99mTc-MDP whole-body BS (p<0.001). F-FDG PET/CT has a higher diagnostic value than 99m Tc-MDP whole-body BS in the detection of osteolytic bone metastases, especially in the vertebra

  11. Computed tomography of the llama head: technique and normal anatomy

    International Nuclear Information System (INIS)

    Hathcock, J.T.; Pugh, D.G.; Cartee, R.E.; Hammond, L.

    1996-01-01

    Computed tomography was performed on the head of 6 normal adult llamas. The animals were under general anesthesia and positioned in dorsal recumbency on the scanning table. The area scanned was from the external occipital protuberance to the rostral portion of the nasal passage, and the images are presented in both a bone window and a soft tissue window to allow evaluation and identification of the anatomy of the head. Computed tomography of the llama head can be accomplished by most computed tomography scanners utilizing a technique similar to that used in small animals with minor modification of the scanning table

  12. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the examination table will move during the scan, so that the x-ray beam follows a spiral ... and additional view capabilities. Modern CT scanners are so fast that they can scan through large sections ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the examination table will move during the scan, so that the x-ray beam follows a spiral ... and additional view capabilities. Modern CT scanners are so fast that they can scan through large sections ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits A CT scan is one of the safest ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... particularly the lungs, abdomen, pelvis and bones. A diagnosis determined by CT scanning may eliminate the need ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... medical device of any kind, unlike MRI. A diagnosis determined by CT scanning may eliminate the need ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... benefits vs. risks? Benefits A CT scan is one of the safest means of studying the sinuses. ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... sometimes compared to looking into a loaf of bread by cutting the loaf into thin slices. When ... actual CT scanning is performed. Depending on the type of CT scan, the machine may make several ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits A CT scan is one of the ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... air-filled spaces within the bones of the face surrounding the nasal cavity. CT scanning is painless, ... and blood vessels. A CT scan of the face produces images that also show a patient's paranasal ...

  4. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  6. Evaluation of Optic Canal and Surrounding Structures Using Cone Beam Computed Tomography: Considerations for Maxillofacial Surgery.

    Science.gov (United States)

    Sinanoglu, Alper; Orhan, Kaan; Kursun, Sebnem; Inceoglu, Beste; Oztas, Bengi

    2016-07-01

    The optic canal connects the anterior cranial fossa and the orbit and maintains the optic nerve and the ophthalmic artery. Within the extent of the surgical approach of the region, risk of iatrogenic injury of the neural and vascular structures increases. The aim of this retrospective morphometric study is to investigate the radiological anatomy of orbita, optic canal, and its surrounding using cone beam computed tomography (CBCT) scans in a group of Turkish population.Cone beam computed tomography images of a total of 182 patients were evaluated by 2 observers. Anatomical parameters regarding optic canal and orbita were measured for all patients from axial, sagittal, and three-dimensional reconstructed images. To assess intraobserver reliability, the Wilcoxon matched-pairs test was used. Pearson χ test and Student t test were performed for statistical analysis of differences, sex, localization, and measurements (P  0.05). The orbita width and height were larger for the males than females (P  0.05). Examination CBCT scans revealed that the shape of the optic canal was 70% funnel and 28% Hourglass shape, 2% amorph type round.These results provide detailed knowledge of the anatomical characteristics in the orbital area which may be of assistance for surgeons preoperatively. Cone beam computed tomography scans can be an alternative modality for multislice computed tomography with submillimeter resolution and lower dose in preoperative imaging of the orbit.

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  9. Recent Developments in Computed Tomography

    International Nuclear Information System (INIS)

    Braunstein, D.; Dafni, E.; Levene, S.; Malamud, G.; Shapiro, O.; Shechter, G.; Zahavi, O.

    1999-01-01

    Computerized Tomography. has become, during the past few years, one of the mostly used apparatus in X-ray diagnosis. Its clinical applications has penetrated to various fields, like operational guidance, cardiac imaging, computer aided surgery etc. The first second-generation CT scanners consisted of a rotate-rotate system detectors array and an X-ray tube. These scanners were capable of acquiring individual single slices, the duration of each being several seconds. The slow scanning rate, and the then poor computers power, limited the application range of these scanners, to relatively stable organs, short body coverage at given resolutions. Further drawbacks of these machines were weak X-ray sources and low efficiency gas detectors. In the late 80's the first helical scanners were introduced by Siemens. Based on a continuous patient couch movement during gantry rotation, much faster scans could be obtained, increasing significantly the volume coverage at a given time. In 1992 the first dual-slice scanners, equipped with high efficiency solid state detectors were introduced by Elscint. The acquisition of data simultaneously from two detector arrays doubled the efficiency of the scan. Faster computers and stronger X-ray sources further improved the performance, allowing for a new range of clinical applications. Yet, the need for even faster machines and bigger volume coverage led to further R and D efforts by the leading CT manufacturers. In order to accomplish the most demanding clinical needs, innovative 2 dimensional 4-rows solid-state detector arrays were developed, together with faster rotating machines and bigger X-ray tubes, all demanding extremely accurate and robust mechanical constructions. Parallel, multi-processor custom computers were made, in order to allow the on-line reconstruction of the growing amounts of raw data. Four-slice helical scanners, rotating at 0.5 sec per cycle are being tested nowadays in several clinics all over the world. This talk

  10. Computed tomography of the orbital tumors

    International Nuclear Information System (INIS)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck; Ahn, Byeong Yeob

    1987-01-01

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  11. Computed tomography of the orbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Ahn, Byeong Yeob [Han Mi Hospital, Seoul (Korea, Republic of)

    1987-04-15

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  12. Significance of triplane computed tomography in otolaryngology

    International Nuclear Information System (INIS)

    Taiji, Hidenobu; Namiki, Hideo; Kano, Shigeru; Hojoh, Yoshio

    1985-01-01

    The authors obtained direct sagittal CT scans of the head using a new method for positioning the head of patient in sitting position. Direct sagittal scans are more useful than computed rearranged scans in a better spatial and density resolution. The triplane CT (axial, coronal, and sagittal CT) greatly improves three dimentional recognition of the intracranial and facial structures and the extent of the lesion. A series of patients with various nasal and oropharyngeal tumors was examined with the triplane CT. The advantages of direct sagittal scans are (1) the recognition of localization and extension of the lesion. (2) the evaluation of the extent of the deep facial and nasopharygeal tumors, especially in the intracranial and intraorbital regions. (3) the more accurate determination of staging of the maxillary cancer. (author)

  13. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  14. Value of Multidetector Computed Tomography in Assessing Blunt Multitrauma Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ahvenjaervi, L.; Mattila, L.; Ojala, R.; Tervonen, O. [Oulu Univ. Hospital (Finland). Dept. of Diagnostic Radiology

    2005-04-01

    Purpose: To find out if multidetector computed tomography (MDCT), using a dedicated trauma protocol, provides sufficient diagnostic information of the injuries of blunt multitrauma patients to enable the planning of treatment for all body compartments. Material and Methods: One-hundred-and-thirty-three patients exposed to high-energy trauma were referred and scanned with the standardized MDCT multitrauma protocol. The imaging protocol consisted of axial scanning of the head and helical scanning of the facial bones, cervical spine, thorax, abdomen, and pelvis. The scanning times were 12 s for the head, 19-21 s for the facial bones and cervical spine (1 mm collimation), and 32-50 s for the thorax, abdomen, and pelvis (2 mm collimation). One-hundred-and-forty milliliters of non-iodinated contrast material (300 mg I/ml) was administered intravenously at 3 ml/s. Results: Ninety-nine of the patients (74%) had at least one finding consistent with trauma. The most frequent findings were in the thorax in 58 patients (44%). Nineteen false-negative findings and two false-positive findings were made. The overall sensitivity of MDCT was 94%, specificity 100%, and accuracy 97%. Conclusion: MDCT is accurate in the assessment of blunt multitrauma patients. The decision to treat the patient can be made on the basis of MDCT with a reasonable level of certainty.

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different ... lie still is reduced. Though the scanning itself causes no pain, there may be some discomfort from ...

  16. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  17. Automated quantification of pulmonary emphysema from computed tomography scans: comparison of variation and correlation of common measures in a large cohort

    Science.gov (United States)

    Keller, Brad M.; Reeves, Anthony P.; Yankelevitz, David F.; Henschke, Claudia I.

    2010-03-01

    The purpose of this work was to retrospectively investigate the variation of standard indices of pulmonary emphysema from helical computed tomographic (CT) scans as related to inspiration differences over a 1 year interval and determine the strength of the relationship between these measures in a large cohort. 626 patients that had 2 scans taken at an interval of 9 months to 15 months (μ: 381 days, σ: 31 days) were selected for this work. All scans were acquired at a 1.25mm slice thickness using a low dose protocol. For each scan, the emphysema index (EI), fractal dimension (FD), mean lung density (MLD), and 15th percentile of the histogram (HIST) were computed. The absolute and relative changes for each measure were computed and the empirical 95% confidence interval was reported both in non-normalized and normalized scales. Spearman correlation coefficients are computed between the relative change in each measure and relative change in inspiration between each scan-pair, as well as between each pair-wise combination of the four measures. EI varied on a range of -10.5 to 10.5 on a non-normalized scale and -15 to 15 on a normalized scale, with FD and MLD showing slightly larger but comparable spreads, and HIST having a much larger variation. MLD was found to show the strongest correlation to inspiration change (r=0.85, pemphysema index and fractal dimension have the least variability overall of the commonly used measures of emphysema and that they offer the most unique quantification of emphysema relative to each other.

  18. Cranial computed tomography of the neurofibromatosis

    International Nuclear Information System (INIS)

    Fukuda, Teruo; Inoue, Yuichi; Shibakiri, Ippei

    1981-01-01

    The computed tomography (CT) was performed in 10 cases of neurofibromatosis. The CT scan showed the abnormal findings in 8 cases out of 10. Skull lesions were noted in 3 cases and intracranial tumors were found in 5 among which multiple neoplasms were seen in 3. Although reported cases were not large enough in number, the incidence and variety of the tumors were similar to others reported before CT era. (author)

  19. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  20. Incidence of traumatic carotid and vertebral artery dissections: results of cervical vessel computed tomography angiogram as a mandatory scan component in severely injured patients

    Directory of Open Access Journals (Sweden)

    Schicho A

    2018-01-01

    Full Text Available Andreas Schicho,1 Lukas Luerken,1 Ramona Meier,1 Antonio Ernstberger,2 Christian Stroszczynski,1 Andreas Schreyer,1 Lena-Marie Dendl,1 Stephan Schleder1 1Department of Radiology, 2Department of Trauma Surgery, University Medical Center, Regensburg, Germany Purpose: The aim of this study was to evaluate the true incidence of cervical artery dissections (CeADs in trauma patients with an Injury Severity Score (ISS of ≥16, since head-and-neck computed tomography angiogram (CTA is not a compulsory component of whole-body trauma computed tomography (CT protocols. Patients and methods: A total of 230 consecutive trauma patients with an ISS of ≥16 admitted to our Level I trauma center during a 24-month period were prospectively included. Standardized whole-body CT in a 256-detector row scanner included a head-and-neck CTA. Incidence, mortality, patient and trauma characteristics, and concomitant injuries were recorded and analyzed retrospectively in patients with carotid artery dissection (CAD and vertebral artery dissection (VAD. Results: Of the 230 patients included, 6.5% had a CeAD, 5.2% had a CAD, and 1.7% had a VAD. One patient had both CAD and VAD. For both, CAD and VAD, mortality is 25%. One death was caused by fatal cerebral ischemia due to high-grade CAD. A total of 41.6% of the patients with traumatic CAD and 25% of the patients with VAD had neurological sequelae. Conclusion: Mandatory head-and-neck CTA yields higher CeAD incidence than reported before. We highly recommend the compulsory inclusion of a head-and-neck CTA to whole-body CT routines for severely injured patients. Keywords: polytrauma, carotid artery, vertebral artery, dissection, blunt trauma, computed tomography angiogram

  1. CASE SERIES Multi-detector computer tomography venography ...

    African Journals Online (AJOL)

    in the curved coronal plane with particular reference to the course of the common and external iliac veins through the pelvis. Axial venous. Aim. To evaluate the role of multi-detector computer tomography venography (MDCTV), compared with conventional venography, as a diagnostic tool in the management of patients with ...

  2. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... applications. This thesis takes a systematic approach toward establishing quantitative understanding of conditions for sparse reconstruction to work well in CT. A general framework for analyzing sparse reconstruction methods in CT is introduced and two sets of computational tools are proposed: 1...... contributions to a general set of computational characterization tools. Thus, the thesis contributions help advance sparse reconstruction methods toward routine use in...

  3. A very rare cause of dyspnea with a unique presentation on a computed tomography scan of the chest: macrophage activation syndrome

    International Nuclear Information System (INIS)

    Brandao-Neto, Rodrigo Antonio; Santana, Alfredo Nicodemos Cruz; Danilovic, Debora Lucia Seguro; Mendonca, Berenice Bilharinho de; Bernardi, Fabiola Del Carlo; Barbas, Carmen Silvia Valente

    2008-01-01

    Macrophage activation syndrome is a rare and potentially life-threatening disease. It occurs due to immune dysregulation manifested as excessive macrophage proliferation, typically causing hepatosplenomegaly, pancytopenia and hepatic dysfunction. Here, we report an unusual case of macrophage activation syndrome presenting as dyspnea, as well as (reported here for the first time) high resolution computed tomography findings of an excavated nodule, diffuse ground glass opacities and consolidations (mimicking severe pneumonia or alveolar hemorrhage). The patient was successfully treated with human immunoglobulin. We recommend that macrophage activation syndrome be considered in the differential diagnosis of respiratory failure. Rapid diagnosis and treatment are essential to achieving favorable outcomes in patients with this syndrome. (author)

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... is reduced. Though the scanning itself causes no pain, there may be some discomfort from having to ... time staying still, are claustrophobic, or have chronic pain, you may find a CT exam to be ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... is reduced. Though the scanning itself causes no pain, there may be some discomfort from having to ... time staying still, are claustrophobic or have chronic pain, you may find a CT exam to be ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... that lasts for at most a minute or two. You may experience a sensation like you have ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... that lasts for at most a minute or two. You may experience a sensation like you have ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of ... tissue and blood vessels provide greater detail than traditional x-rays, particularly of soft tissues and blood ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of ... tissue and blood vessels provide greater detail than traditional x-rays, particularly of soft tissues and blood ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... its ability to image bone, soft tissue and blood vessels all at the same time. Unlike conventional x-rays, CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... its ability to image bone, soft tissue and blood vessels all at the same time. Unlike conventional x-rays, CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... lie still is reduced. Though the scanning itself causes no pain, there may be some discomfort from ... Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... cavities (ventricles) in patients with hydrocephalus . diseases or malformations of the skull. CT scanning is also performed ... biopsy ) from the brain. assess aneurysms or arteriovenous malformations through a technique called CT angiography. For more ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... is painless, noninvasive and accurate. It’s also the most reliable imaging technique for determining if the sinuses ... CT scan of the sinuses, the patient is most commonly positioned lying flat on the back. The ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the nasal cavity. CT scanning is painless, noninvasive and accurate. It’s ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you’re taking, and allergies. You ... a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you’re taking, and allergies. You ... a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... a relatively short time, especially when compared to magnetic resonance imaging (MRI). CT scanning is painless, noninvasive and ... the extent of soft tissue of the tumor, magnetic resonance imaging (MRI) may be helpful. A person who ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... in CT scans should have no immediate side effects. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... in CT scans should have no immediate side effects. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... verifies that the images are of high enough quality for accurate interpretation. The actual CT scan takes less than a minute and the entire process is usually completed within 10 minutes. top of ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tissue damage in patients with facial trauma, and planning surgical reconstruction. diagnose diseases of the temporal bone ... CT scanning may eliminate the need for exploratory surgery and surgical biopsy. No radiation remains in a ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... See the Safety page for more information about pregnancy and x-rays. top of page What does ... See the Safety page for more information about pregnancy and x-rays. CT scanning is, in general, ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... See the Safety page for more information about pregnancy and x-rays. top of page What does ... See the Safety page for more information about pregnancy and x-rays. CT scanning is, in general, ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... in the womb. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... liver, shows up in shades of gray, and air appears black. With CT scanning, numerous x-ray ... cause blurring of the images and degrade the quality of the examination the same way that it ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... cavity. CT scanning is painless, noninvasive and accurate. It’s also the most reliable imaging technique for determining ... parts absorb the x-rays in varying degrees. It is this crucial difference in absorption that allows ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... in the paranasal sinuses. plan radiation therapy for cancer of the brain or other tissues. guide the ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... therapy for brain cancer. In emergency cases, it can reveal internal injuries and bleeding quickly enough to ... cross-sectional images generated during a CT scan can be reformatted in multiple planes, and can even ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... that are filled with fluid or thickened sinus membranes . detect the presence of inflammatory diseases. provide additional ... over time. top of page What are the benefits vs. risks? Benefits A CT scan is one ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for children who cannot hold still. Motion will cause blurring of the images and degrade the quality ... lie still is reduced. Though the scanning itself causes no pain, there may be some discomfort from ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... up in shades of gray, and air appears black. With CT scanning, numerous x-ray beams and ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... up in shades of gray, and air appears black. With CT scanning, numerous x-ray beams and ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...