WorldWideScience

Sample records for computed tomography-guided fine-needle

  1. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  2. Computed tomography-guided needle biopsy of lung lesions in fourteen cats and dogs

    International Nuclear Information System (INIS)

    Yoshida, K.; Mori, T.; Yamada, M.; Sakaida, M.; Yonemaru, K.; Murakami, M.; Sakai, H.; Maruo, K.

    2007-01-01

    Computed tomography (CT)-guided fine-needle aspirates (FNA) or core biopsies of lung lesions were performed in nine dogs and five cats. A clinical diagnosis was obtained in twelve of fourteen animals (85%), namely 80% FNA and 100% core biopsies. Eight animals had other mass (es) apart from the lung, and five were diagnosed to metastases. In only one case, the lung mass was histopathologically diagnosed as a malignant primary tumor. Iatrogenic complications through the lung biopsies were noted in four animals, and three showed mild pneumothorax on CT images and one was bleeding from the needle. However, between fifteen and thirty minutes after the biopsy, no animal indicated signs of pneumothorax or hemorrhage

  3. Computed tomography-guided core-needle biopsy of lung lesions: an oncology center experience

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; Fonte, Alexandre Calabria da; Chojniak, Rubens, E-mail: marcosduarte@yahoo.com.b [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Radiology and Imaging Diagnosis; Andrade, Marcony Queiroz de [Hospital Alianca, Salvador, BA (Brazil); Gross, Jefferson Luiz [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Chest Surgery

    2011-03-15

    Objective: The present study is aimed at describing the experience of an oncology center with computed tomography guided core-needle biopsy of pulmonary lesions. Materials and Methods: Retrospective analysis of 97 computed tomography-guided core-needle biopsy of pulmonary lesions performed in the period between 1996 and 2004 in a Brazilian reference oncology center (Hospital do Cancer - A.C. Camargo). Information regarding material appropriateness and the specific diagnoses were collected and analyzed. Results: Among 97 lung biopsies, 94 (96.9%) supplied appropriate specimens for histological analyses, with 71 (73.2%) cases being diagnosed as malignant lesions and 23 (23.7%) diagnosed as benign lesions. Specimens were inappropriate for analysis in three cases. The frequency of specific diagnosis was 83 (85.6%) cases, with high rates for both malignant lesions with 63 (88.7%) cases and benign lesions with 20 (86.7%). As regards complications, a total of 12 cases were observed as follows: 7 (7.2%) cases of hematoma, 3 (3.1%) cases of pneumothorax and 2 (2.1%) cases of hemoptysis. Conclusion: Computed tomography-guided core needle biopsy of lung lesions demonstrated high rates of material appropriateness and diagnostic specificity, and low rates of complications in the present study. (author)

  4. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens

    2002-01-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  5. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses.

    Science.gov (United States)

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-10-01

    Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate.

  6. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  7. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  8. Uncommon primary tumors of the orbit diagnosed by computed tomography-guided core needle biopsy: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Matushita Junior, Joao Paulo Kawaoka; Bitencourt, Almir Galvao Vieira; Amoedo, Mauricio Kauark; Barbosa, Paula Nicole Vieira; Chojniak, Rubens, E-mail: almirgvb@yahoo.com.br [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil). Dept. de Imagem; Neves, Flavia Branco Cerqueira Serra [Hospital do Servidor Publico Estadual, Sao Paulo, SP (Brazil). Div. de Oftalmologia

    2014-11-15

    Computed tomography-guided percutaneous biopsy is a safe and effective alternative method for evaluating selected intra-orbital lesions where the preoperative diagnosis is important for the therapeutic planning. The authors describe two cases of patients with uncommon primary orbital tumors whose diagnosis was obtained by means of computed tomography-guided core needle biopsy, with emphasis on the technical aspects of the procedure. (author)

  9. ULTRASONOGRAPHY AND COMPUTED TOMOGRAPHY GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSING INTRA-ABDOMINAL LESIONS- A 6-YEAR RETROSPECTIVE STUDY IN A TERTIARY CARE HOSPITAL IN MANIPUR

    Directory of Open Access Journals (Sweden)

    Ratan Konjengbam

    2017-07-01

    Full Text Available BACKGROUND Fine-Needle Aspiration Cytology (FNAC is a widely used method, which is accurate and safe in a readily palpable masses. But, in those inaccessible lesions and deeper organs are safely aspirated using fine needle radiological procedure like ultrasound or computed tomography guided. The aim of the study is to assess the utility of FNAC in the diagnosis of intra-abdominal lesions and different pattern of lesions in particular to the sites. MATERIALS AND METHODS This retrospective study was done in the Department of Pathology, Regional Institute of Medical Sciences (RIMS, Imphal, between June 2010 and June 2016. The study included 128 intra-abdominal masses. Giemsa and Papanicolaou’s stains were used. The cytological diagnosis was correlated with clinical and radiological data to arrive at a final diagnosis. RESULTS Reports on FNAC smears were retrospectively analysed, which had been done in various anatomic sites- liver (70 cases, colon (19 cases, gallbladder (17 cases, mesenteric lymph nodes (12 cases, ovary (3 cases, adrenals (2 cases and 1 case each of pancreas, peritoneal wall, pelvic, suprapubic and flank masses. The mean age was 42.16 years with M:F of 1.3:1. The diagnostic yield was 85.2% in combination for Ultrasound Guided (USG and Computed Tomography (CT guided aspiration. The smears were classified as benign neoplastic, malignant neoplastic, non-neoplastic, inconclusive and unsatisfactory for interpretation. There were 79 (61.7% malignant neoplastic lesion, 5 (3.9% benign neoplastic lesion, 25 (19.5% non-neoplastic lesion, one (0.7% inconclusive lesions and 18 (14.1% unsatisfactory smears. The liver and the colon were the most common sites. Adenocarcinomas and Hepatocellular Carcinoma (HCC were the most common malignant lesions comprising of 35 (44.3% and 25 (31.6% of the total malignant lesions diagnosed. CONCLUSION Intra-abdominal FNA is a simple, economical and a safe procedure with high sensitivity, specificity and

  10. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  11. Computed tomography-guided percutaneous core needle biopsy of deep seated bone lesions in two dogs

    International Nuclear Information System (INIS)

    Mori, T.; Sakaida, M.; Yamada, M.; Akiyama, H.; Takai, Y.; Sakai, H.; Maruo, K.

    2006-01-01

    Computed Tomography (CT)-guided percutaneous core needle biopsies were undertaken for the diagnosis of osteosarcoma in the pelvis (case 1) and myeloma (case 2) in the seventh lumber vertebra which were difficult to targeted by palpation, ultrasound or fluoroscopy. In both cases, enough tissue for pathological diagnosis were obtained without any complication. CT-guided biopsy was thought to be a safe, easy and effective technique for the evaluation of the deep seated bone lesion

  12. The value of ultrasound with ultrasound-guided fine-needle aspiration biopsy compared to computed tomography in the detection of regional metastases in the clinically negative neck

    International Nuclear Information System (INIS)

    Takes, Robert P.; Righi, Paul; Meeuwis, Cees A.; Manni, Johannes J.; Knegt, Paul; Marres, Henri A.M.; Spoelstra, Hubert A.A.; Boer, Maarten F. de; Mey, Andel G.L. van der; Bruaset, I.; Ball, Valerie; Weisberger, Edward; Radpour, Shokri; Kruyt, Rene H.; Joosten, Frank B.M.; Lameris, Johan S.; Oostayen, Jacques A. van; Kopecky, Kenyon; Caldemeyer, Karen; Henzen-Logmans, Sonja C.; Wiersma-van Tilburg, J.M.; Bosman, Fred T.; Krieken, J. Han J.M. van; Hermans, Jo; Baatenburg de Jong, Robert J.

    1998-01-01

    Purpose: Head and neck oncologists have not reached consensus regarding the role of contemporary imaging techniques in the evaluation of the clinically negative neck in patients with head and neck squamous cell carcinoma (HNSCC). The purpose of the present study was to compare the accuracy of ultrasound with guided fine-needle aspiration biopsy (UGFNAB) and computed tomography (CT) in detecting lymph node metastasis in the clinically negative neck. Methods and Materials: Sixty-four neck sides of patients with HNSCC were examined preoperatively by ultrasound/UGFNAB and CT at one of five participating tertiary care medical centers. The findings were correlated with the results of histopathologic examination of the neck specimen. Results: Ultrasound with guided fine-needle aspiration biopsy was characterized by a sensitivity of 48%, specificity of 100%, and overall accuracy of 79%. Three cases had nondiagnostic aspirations using UGFNAB and were excluded. CT demonstrated a sensitivity of 54%, specificity of 92%, and overall accuracy of 77%. UGFNAB detected two additional metastases not visualized on CT, whereas CT detected no metastases not seen on UGFNAB. The results of UGFNAB were similar between the participating centers. Conclusions: Approximately one half of the clinically occult nodal metastases in our patient group were identified by both CT and UGFNAB. Overall, UGFNAB and CT demonstrated comparable accuracy. The sensitivity of CT was slightly better than UGFNAB, but the latter remained characterized by a superior specificity. The results of CT and UGFNAB did not appear to be supplementary. The choice of imaging modality for staging of the clinically negative neck depends on tumor site, T-stage, and experience and preference of the head and neck oncologist. If CT is required for staging of the primary tumor, additional staging of the neck by UGFNAB does not provide significant additional value

  13. Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Staging of Patients with Non-Small Cell Lung Cancer without Mediastinal Involvement at Positron Emission Tomography-Computed Tomography

    DEFF Research Database (Denmark)

    Naur, Therese Maria Henriette; Konge, Lars; Clementsen, Paul Frost

    2017-01-01

    BACKGROUND: Staging of lung cancer is essential to the treatment, which is curative only in cases of localized disease. Previous studies have suggested that endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unnecessary when positron emission tomography-computed tomog...

  14. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  15. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  16. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  17. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  18. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  19. Scan-guided fine needle aspiration biopsy in malignant hepatic disease

    International Nuclear Information System (INIS)

    Johansen, P.; Svendsen, K.N.

    1978-01-01

    The method of scan-guided fine needle aspiration biopsy of the liver is described, and the diagnostic value of this combined method in the diagnosis of malignant hepatic disease is evaluated in 83 confirmed cases, showing a specificity of 100% and a sensitivity of 94%. The combined method is compared to liver scanning alone and to Menghini biopsy. Different methods for the diagnosis of malignant hepatic disease are discussed, and it is concluded that scan-guided fine needle aspiration biopsy has a diagnostic value only obtainable otherwise by a combination of liver scanning and biopsy during laparoscopy. Cytologic features in the two most common tumor types in this study, i.e., metastatic colonic adenocarcinoma and hepatocarcinoma, are presented along with a brief discussion of the specificity of the cytologic diagnosis of hepatocarcinoma

  20. Pancreatic metastases from ocular malignant melanoma: the use of endoscopic ultrasound-guided fine-needle aspiration to establish a definitive cytologic diagnosis: a case report

    Directory of Open Access Journals (Sweden)

    Diogo Turiani Hourneaux De Moura

    2016-12-01

    Full Text Available Abstract Background When encountering solid pancreatic lesions, nonpancreatic primary metastases are rare and differentiating a metastasis from a primary neoplastic lesion is challenging. The clinical presentation and radiologic features can be similar and the possibility of a pancreatic metastasis should be considered when the patient refers to a history of a different primary cancer. Endoscopic ultrasound offers a key anatomical advantage in accessing the pancreas and endoscopic ultrasound-guided fine-needle aspiration has become the gold standard method for diagnosing pancreatic lesions. Case presentation A 58-year-old white Hispanic woman with a history of uveal malignant melanoma, presented with abdominal pain and jaundice. On admission, laboratory tests were performed (her total bilirubin was 6.37 mg/dL with a direct fraction of 5.30 mg/dL. Cross-sectional, abdominal computed tomography with contrast, showed a low-attenuating lesion localized in the pancreatic head (measuring 4 × 3 cm and a thinner section of the distal bile duct suspicious for compression. Our patient was scheduled for an endoscopic ultrasound-guided fine-needle aspiration to establish a diagnosis. Endoscopic ultrasound showed a solid, hypoechoic, well-defined lesion with regular contours (measuring 3.17 × 2.61 cm, localized between the head and neck of the pancreas. Endoscopic ultrasound-guided fine-needle aspiration was performed with a 22G needle and cytology confirmed the diagnosis of metastatic melanoma. Our patient subsequently underwent right orbital exenteration, followed by duodenopancreatectomy without complications. At the moment our patient is receiving adjuvant chemotherapy at an outside oncology clinic. Conclusions To the best of our knowledge, this is a very rare presentation of an ocular malignant melanoma with an isolated pancreatic metastasis causing symptomatic biliary obstruction. Endoscopic ultrasound-guided fine-needle aspiration has

  1. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    Science.gov (United States)

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1

  2. Role of [18F]fluorodeoxyglucose positron emission tomography-computed tomography, sonography, and sonographically guided fine-needle aspiration biopsy in the diagnosis of axillary lymph nodes in patients with breast cancer: comparison of diagnostic performance.

    Science.gov (United States)

    Sohn, Yu-Mee; Hong, Il Ki; Han, Kyunghwa

    2014-06-01

    The aim of this study was to compare the diagnostic performance of [(18)F]fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) with that of sonography and sonographically guided fine-needle aspiration (FNA) for determining the preoperative axillary lymph node (ALN) status and to evaluate the factors related to false-negative PET-CT, sonographic, and FNA results in ALN staging of invasive ductal carcinoma. From March 2009 to July 2012, 226 patients had a diagnosis of primary breast cancer. Among these patients, 107 constituted the study population after exclusion of transferred patients and patients with breast cancer other than invasive ductal carcinoma. The diagnostic performance of the modalities was compared with pathologic reports. Univariate and multivariate analyses were used to evaluate the relationship between clinicopathologic factors (symptoms, T stage, hormone receptors, and histologic grade), false-negative results, and true-negative results on PET-CT, sonography, and FNA. Of the 107 patients, 45 (42.1%) had positive results on final pathologic analysis of ALNs. Sonographically guided FNA had a significantly higher specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve than sonography and PET-CT (P < .01). When sonography and PET-CT were combined, the sensitivity was significantly improved (P = .019) compared with sonography alone. When FNA and PET-CT were combined, the sensitivity and negative predictive value were significantly increased compared with each modality (P < .01). Sonographically guided FNA was found to be an excellent diagnostic tool for preoperative evaluation of the ALN status. To obviate the step of sentinel lymph node biopsy for determining the ALN status, combined evaluation of ALNs by these modalities may be more complementary than the use of a single modality. © 2014 by the American Institute of Ultrasound in Medicine.

  3. Computed Tomography-Guided Core-Needle Biopsy Specimens Demonstrate Epidermal Growth Factor Receptor Mutations in Patients with Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Chen, C.M.; Chang, J.W.C.; Cheung, Y.C.; Lin, G.; Hsieh, J.J.; Hsu, T.; Huang, S.F.

    2008-01-01

    Background: Target therapy with a new class of epidermal growth factor receptor (EGFR) inhibitors shows improved clinical response in EGFR gene-mutated lung cancers. Purpose: To evaluate the use of computed tomography (CT)-guided core-needle biopsy specimens for the assessment of EGFR gene mutation in non-small-cell lung cancer (NSCLC). Material and Methods: Seventeen (nine males, eight females) patients with advanced NSCLC were enrolled in this study. All patients underwent CT-guided core-needle biopsy of the lung tumor prior to treatment with the EGFR inhibitor gefitinib. There were no life-threatening complications of biopsy. The specimens were sent fresh-frozen for EGFR mutation analysis and histopathological study. Results: There were 12 (70.6%) EGFR gene mutants and five (29.4%) nonmutants. The objective response rate to gefitinib therapy was 73.3% (11 of 15 patients), with 91.7% (11 of 12 mutants) for the mutant group and 0% for the nonmutant group. Conclusion: CT-guided core-needle biopsy of advanced NSCLC enables the acquisition of sufficient tissue for EGFR gene mutation analysis

  4. Computed tomography-guided needle aspiration and biopsy of pulmonary lesions - A single-center experience in 1000 patients

    Energy Technology Data Exchange (ETDEWEB)

    Poulou, Loukia S.; Tsagouli, Paraskevi; Thanos, Loukas [Dept. of Medical Imaging and Interventional Radiology, General Hospital of Chest Diseases ' Sotiria' , Athens (Greece)], e-mail: ploukia@hotmail.com; Ziakas, Panayiotis D. [Program of Outcomes Research, Div. of Infectious Diseases, Warren Alpert Medical School, Brown Univ., RI, and Div. of Infectious Diseases, Rhode Island Hospital, Rhode Island (United States); Politi, Dimitra [Dept. of Cythopathology, General Hospital of Chest Diseases ' Sotiria' Athens (Greece); Trigidou, Rodoula [Dept. of Pathology, General Hospital of Chest Diseases ' Sotiria' Athens (Greece)

    2013-07-15

    Background: Computed tomography (CT)-guided fine needle aspiration (FNA) and biopsies are well-established, minimally invasive diagnostic tools for pulmonary lesions. Purpose: To analyze retrospectively the results of 1000 consecutive lung CT-guided FNA and/or core needle biopsies (CNB), the main outcome measures being diagnostic yield, and complication rates. Material and Methods: Patients considered eligible were those referred to our department for lung lesions. The choice of FNA, CNB, or both was based upon the radiologist's judgment. Diagnostic yield was defined as the probability of having a definite result by cytology/histology. Results: The study included 733 male patients and 267 female patients, with a mean (SD) age of 66.4 (11.4) years. The mean (SD) lesion size was 3.7 (2.4) cm in maximal diameter. Six hundred and forty-one (64%) patients underwent an FNA procedure, 245 (25%) a CNB, and 114 (11%) had been subjected to both. The diagnostic yield was 960/994 (96.6%); this decreased significantly with the use of CNB only (odds ratio [OR] 0.32; 95% CI 0.12 - 0.88; P = 0.03), while it increased with lesion size (OR 1.35; 95% CI 1.03 - 1.79; P = 0.03 per cm increase). In 506 patients (52.7%), a malignant process was diagnosed by cytopathology/histology. The complication rate reached 97/1000 (9.7%); complications included: hemorrhage, 62 (6.2%); pneumothorax, 28 (2.8%); hemorrhage and pneumothorax, 5 (0.5%); and hemoptysis, 2 (0.2%). It was not significantly affected by the type of procedure or localization of the lesion. The overall risk for complications was three times higher for lesions <4 cm (OR 3.26; 95% CI 1.96 - 5.42; P < 0.001). Conclusion: CT-guided lung biopsy has a high diagnostic yield using FNA, CNB, or both. The CNB procedure alone will not suffice. Complication rates were acceptable and correlated inversely with lesion size, not localization or type of procedure.

  5. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  6. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  7. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  8. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    Science.gov (United States)

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  9. A Comparison of Endoscopic Ultrasound Guided Biopsy and Positron Emission Tomography with Integrated Computed Tomography in Lung Cancer Staging

    DEFF Research Database (Denmark)

    Larsen, Stine Schmidt; Vilmann, P; Krasnik, K

    2009-01-01

    BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...... had both procedures performed. PATIENTS AND METHODS: 27 patients considered to be potential candidates for resection of NSCLC underwent PET/CT and EUS-FNA. Diagnoses were confirmed either by open thoracotomy, mediastinoscopy or clinical follow-up. Advanced lung cancer was defined as tumour...

  10. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  11. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    International Nuclear Information System (INIS)

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L.

    2010-01-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  12. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  13. Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

    DEFF Research Database (Denmark)

    Larsen, M H; Fristrup, C W; Detlefsen, S

    2018-01-01

    Background and study aim : Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions...

  14. Radiographic-guided fine-needle aspiration of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Helvie, M.A.; Baker, D.E.; Adler, D.D.; Andersson, I.; Naylor, B.; Buckwalter, K.

    1989-01-01

    The authors have performed radiographically guided fine-needle aspirations (FNA) on 215 nonpalpable mammographically detected breast lesions, using a coordinate grid localization system. Aspirates were classified into five cytologic groups. With the most stringent cytologic criteria, the sensitivity was 98% and the specificity 95% for the detection of carcinoma. However, according to these strict cytologic criteria, only 46% of aspirates contained representative material. Forty-two of 74 lesions undergoing biopsy proved malignant. Sixteen percent of patients did not compete adequate mammographic follow-up. High sensitivity and specificity can be achieved with radiographically guided FNA. However, management decisions ultimately require integration of mammographic findings with cytologic results. Close cooperation between mammographer, surgeon, cytopathologist, and patients is mandatory for successful operation

  15. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences; Evaluierung einer neuen Seldinger-Nadel fuer computertomografisch gesteuerte Interventionen: Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Plumhans, C.; Mahnken, A.; Iwa, R.; Behrendt, F.F.; Sebastian, K.; Guenther, R.W.; Honnef, D. [Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2009-02-15

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 {+-} 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  16. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  17. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  18. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  19. Computer-Aided Design/Computer-Assisted Manufacture-Derived Needle Guide for Injection of Botulinum Toxin into the Lateral Pterygoid Muscle in Patients with Oromandibular Dystonia.

    Science.gov (United States)

    Yoshida, Kazuya

    2018-01-01

    To evaluate the effectiveness and safety of botulinum toxin administration into the inferior head of the lateral pterygoid muscle of patients with jaw opening dystonia by using a computer-aided design/computer-assisted manufacture (CAD/CAM)-derived needle guide. A total of 17 patients with jaw opening dystonia were enrolled. After the patient's computed tomography (CT) scan was imported and fused with a scan of a plaster cast model of the maxilla, the optimal needle insertion site over the lateral pterygoid muscle was determined using the NobelClinician software. A total of 13 patients were injected both with and without the guide, and 4 patients underwent guided injection alone. The therapeutic effects of botulinum toxin injection and its associated complications were statistically compared between the guided and unguided procedures using paired t test. Botulinum toxin therapy was performed 42 and 32 times with and without the guides, respectively. The needle was easily inserted without any complications in all procedures. There was a significant difference (P < .001) between the mean comprehensive improvements observed with (66.3%) and without (54.4%) the guides. The findings suggest that the use of needle guides during the injection of botulinum toxin into the inferior head of the lateral pterygoid muscle is very useful for aiding the accurate and safe administration of botulinum toxin therapy for jaw opening dystonia.

  20. Microscopic findings in EUS-guided fine needle (SharkCore) biopsies with type 1 and type 2 autoimmune pancreatitis

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Joergensen, Maiken Thyregod; Mortensen, Michael Bau

    2017-01-01

    The International Consensus Diagnostic Criteria (ICDC) for the diagnosis of autoimmune pancreatitis (AIP) include the histological criterion that is based on either pancreatic core needle biopsies (CNBs) or surgical specimens. However, CNBs are difficult to obtain by endoscopic ultrasound (EUS......). EUS fine-needle aspiration (EUS-FNA) cytology is usually not sufficient for the diagnosis of AIP, but may sometimes contain tissue microfragments. Another approach is EUS-guided histological fine-needle biopsy (EUS-FNB), using needles such as the SharkCore or ProCore needle. Published data regarding...... EUS-guided SharkCore FNB for the diagnosis of AIP are lacking. We aimed to describe our histological findings in one type 1 and two type 2 AIP patients who underwent EUS SharkCore FNB. The EUS-FNBs of two patients fulfilled the histological level 2 ICDC for type 1 AIP or type 2 AIP. The EUS-FNB of one...

  1. INITIAL EXPERIENCE WITH ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION OF RENAL MASSES: indications, applications and limitations

    Directory of Open Access Journals (Sweden)

    Renata Nobre MOURA

    2014-12-01

    Full Text Available Context Tissue sampling of renal masses is traditionally performed via the percutaneous approach or laparoscopicaly. The utility of endoscopic ultrasound to biopsy renal lesions it remains unclear and few cases have been reported. Objectives To evaluate the feasibility and outcome of endoscopic ultrasound fine needle aspiration of renal tumors. Methods Consecutive subjects undergoing attempted endoscopic ultrasound fine needle aspiration of a kidney mass after evaluation with computerized tomography or magnetic resonance. Results Ten procedures were performed in nine male patients (median age 54.7 years on the right (n = 4 and left kidney (n = 4 and bilaterally (n = 1. Kidney masses (median diameter 55 mm ; range 13-160 mm were located in the upper pole (n = 3, the lower pole (n = 2 and the mesorenal region (n = 3. In two cases, the mass involved more than one kidney region. Surgical resection confirmed renal cell carcinoma in six patients in whom pre-operative endoscopic ultrasound fine needle aspiration demonstrated renal cell carcinoma. No complications were reported. Conclusions Endoscopic ultrasound fine needle aspiration appears as a safe and feasible procedure with good results and minimal morbidity.

  2. The use of computerised tomography guided percutaneous fine needle aspiration in the evaluation of solitary pulmonary nodules.

    LENUS (Irish Health Repository)

    Khan, K A

    2012-02-01

    The evaluation of a solitary pulmonary nodule (SPN) has changed over the years with increased access to percutaneous computerised tomography (CT) guided fine needle aspiration (FNA), where bronchoscopy is unhelpful. The aim of our study was to evaluate the sample adequacy, diagnostic and complication rate of CT-FNA of a SPN at our academic teaching hospital over an 18 month period. CT-FNA was performed by a radiologist, with a cytopathologist in attendance to confirm the adequacy of the sample obtained. The size of the nodule, sample material and adequacy, diagnosis and complications were recorded. A total of 101 patients were included, 54 male and the mean age was 68 +\\/- 11 years. The mean size of the SPN was 2.3 cm (range 1-11 cm). 56 (56%) patients had a right SPN, 45 (45%) had a left SPN. CT-FNA was diagnostic in 80 (80%) patients and non-diagnostic in 21 (20%) patients. The sample was insufficient for immunocytochemistry, although the morphological appearance was diagnostic in 20 (25%) of the 80 patients. Pneumothorax occurred in 26\\/101 (26%) patients post CT-FNA, of these 7 (27%) required chest drain insertion, while 19 (73%) were managed conservatively. CT FNA is a useful tool for the diagnosis of a SPN, with our diagnostic accuracy comparable to that reported in the literature. However, CT-FNA may not provide adequate sample volume to perform ancillary testing and has a moderate complication rate.

  3. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  4. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  5. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    Science.gov (United States)

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  6. About the diagnostic accuracy rate of fluoroscopy-guided fine needle puncture

    International Nuclear Information System (INIS)

    Wernecke, K.; Teske, H.J.

    1983-01-01

    Percutaneous fine-needle biopsies guided by X-ray were performed in 100 patients utilizing the Nordenstroem canule. All cases have now been clinically controlled for at least 14 and up to 30 months. The follow up allowed further conclusions due to the dignity of histologically negative biopsies. Positive results on malignant lesions were obtained in 74% of cases. Our experience revealed that negative aspiration biopsies should be considered false negative until they could be confirmed by further investigations. (orig.) [de

  7. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  8. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  9. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  10. Guided fine needle aspiration cytology of retroperitoneal masses - Our experience

    Directory of Open Access Journals (Sweden)

    Mimi Gangopadhyay

    2011-01-01

    Full Text Available Background : Early pathological classification of retroperitoneal masses is important for pin-point diagnosis and timely management. Aims : This study was done to evaluate the usefulness and drawbacks of guided fine needle aspiration cytology (FNAC of retroperitoneal masses covering a period of two years with an intention to distinguish between neoplastic and non-neoplastic lesions and to correlate with histologic findings. Materials and Methods : FNAC was done under radiological guidance in all cases using long needle fitted with disposable syringe. Appropriate staining was done and cytology was correlated with histology which was taken as the gold standard for comparison. Results : Fifty-one patients who presented with retroperitoneal masses were studied. Forty-four lesions were malignant cytologically and 7 were inflammatory (tuberculous. According to radiological and cytologic findings, we classified our cases into four groups: renal tumors, retroperitoneal lymphadenopathy, germ cell tumors, soft tissue tumors. Except for cases of non-Hodgkin lymphoma (NHL and metastatic lesions, we had sensitivity and specificity of 100%. In NHL the sensitivity and specificity were both 50%. In cases of metastatic adenocarcinoma, the sensitivity and specificity were 84.6% and 81.8%, respectively. Conclusions : Ignoring the pitfalls, guided FNAC is still an inexpensive and reliable method of early diagnosis of retroperitoneal lesions.

  11. Fine needle aspiration cytology of parapharyngeal tumors

    Directory of Open Access Journals (Sweden)

    Mondal Palash

    2009-01-01

    Full Text Available Background: Parapharyngeal tumors are rare and often pose diagnostic difficulties due to their location and plethora of presentations. Objectives: The study was undertaken to study the occurrence in the population and to evaluate the exact nature by fine needle aspiration cytology (FNAC. Materials and Methods: A total of five hundred and six cases of lateral neck lesions were studied over three and half years. Of these 56 suspected parapharyngeal masses were selected by clinical and radiological methods. Cytopathology evaluation was done by fine needle aspiration cytology with computed tomography and ultrasonography guidance wherever necessary. Histopathology confirmation was available in all the cases. Results: On FNAC diagnosis could be established in 54 cases while in two cases the material was insufficient to establish a diagnosis. The tumors encountered were, pleomorphic adenoma (33, schwannoma (3, neurofibroma (11, paraganglioma (5, angiofibroma (1 and adenoid cystic carcinoma (1. Four false positives and two false negative cases were encountered. Overall sensitivity was 96%, with specificity of 99% and accuracy being 98.8%. Conclusions: With proper clinical and radiological assessment, FNAC can be extremely useful in diagnosing most of these lesions except a few which need histopathological and even immunohistochemical confirmation.

  12. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection; Biopsia percutanea de massas pancreaticas guiada por tomografia computadorizada com pneumodisseccao

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens, E-mail: chiangjengtyng@gmail.com [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Imagem; Coimbra, Felipe Jose Fernandez [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Cirurgia Abdominal

    2013-05-15

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  13. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Cristiano Dias de; Nunes, Rodolfo Acatauassu; Saito, Eduardo Haruo; Higa, Claudio; Cardona, Zanier Jose Fernando; Santos, Denise Barbosa dos, E-mail: cristianodiaslima@gmail.co [Hospital Universitario Pedro Ernesto (HUPE/UERJ), Rio de Janeiro, RJ (Brazil). Dept. Cirurgia Toracica

    2011-03-15

    Objective: to analyze the cytological findings of CT-guided percutaneous fine-needle aspiration biopsies of the lung, to demonstrate the diagnostic feasibility of the method in the investigation of pulmonary lesions, and to determine the complications of the procedure, evaluating its safety. Methods: a retrospective analysis of 89 patients with various types of pulmonary lesions who underwent 97 procedures over a period of five years. The patients were divided into groups regarding the indication for the procedure: suspicion of primary lung cancer (stages IIIB or IV); suspicion of lung cancer (stages I, II, or IIIA) and clinical contraindications for surgery; suspicion of pulmonary metastasis from other organs; and pulmonary lesions with benign radiological aspect. All of the procedures were performed with 25-gauge needles and were guided by spiral CT. The final diagnosis was confirmed by surgical biopsy and clinical/oncological follow-up. For the analysis of complications, the total number of procedures was considered. Results: the main indication for the procedure was suspicion of advanced stage primary lung cancer. The accuracy of the method for malignant lesions was 91.5%. The lesion was confirmed as cancer in 73% of the patients. The major complication was pneumothorax (27.8%), which required chest tube drainage in 12.4% of the procedures. Conclusions: the principal indication for CT-guided fine-needle biopsy was suspicion of primary lung cancer in patients who were not surgical candidates. The procedure has high diagnostic feasibility for malignant pulmonary diseases. The most prevalent complication was pneumothorax. However, in most cases, chest tube drainage was unnecessary. No deaths were related to the procedure. (author)

  14. Mixed germ cell tumor of mediastinum/lung masquerading as hemangioma in fine needle biopsy

    Directory of Open Access Journals (Sweden)

    Rathna Nuti

    2013-01-01

    Full Text Available The histological predominance of one component in a germ cell tumor can lead to a mistaken diagnosis. Here, we describe a mediastinal teratoma with predominant vascular proliferation (>90% which on fine needle biopsy was diagnosed as a pulmonary hemangioma. Later, resection specimen revealed other components constituting ~4%, changing the diagnosis while illustrating theimportance of careful evaluation. A 37-year-old Caucasian male with shortness of breath, weight loss, and history of recently resolved pneumonia was diagnosed with hemangioma, after a computed tomography guided fine needle biopsy of a -16.3-cm mediastinal pulmonary mass revealed abundant benign vascular elements. Following tumor excision, ~94% of the sample exhibited predominant vascular elementsThe mass also exhibited rare focal areas of malignant epithelium in a reticular arrangement and undifferentiated pleomorphic cells associated with vascular invasion. These atypical epithelial cells were positive for CD30, pan CK, AFP, β-HCG and CD 117, thusprocuring a diagnosis of mediastinal mixed germ cell tumor. Although mixed germ cell tumors consist of various tissue types, diagnosis can be easily overlooked if one component dominates. Therefore, obtaining adequate representative neoplasm samples, and sectioning the samples thoroughly, searching for coexisting tissue types is critical for accurate diagnosis.

  15. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  16. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  17. Diagnosis of verminous pneumonia via sonography-guided fine-needle pulmonary parenchymal aspiration in a cat

    Directory of Open Access Journals (Sweden)

    Jennifer Gambino

    2016-04-01

    Full Text Available Case summary A 9-year-old, male neutered, indoor–outdoor domestic shorthair cat from the northern Alabama countryside presented for a 3 week history of coughing, lethargy and an episode of self-resolving dyspnea that occurred 1 week prior to presentation. Three-view thoracic radiographs revealed a moderate-to-severe, diffuse, mixed bronchial to structured interstitial (miliary-to-nodular pulmonary pattern in all lung lobes with peribronchial cuffing and multifocal areas of mild patchy alveolar opacity. Ultrasound-guided evaluation and fine-needle aspiration of the caudodorsal lung parenchyma was performed with sedation. Cytology revealed many widely scattered Aelurostrongylus abstrusus larvae and ova. Upon the confirmed diagnosis of A abstrusus verminous pneumonia, treatment with fenbendazole and selamectin resulted in complete resolution of clinical signs within 6 weeks of the initial diagnosis. Relevance and novel information We report herein the first documented case in the Americas of A abstrusus verminous pneumonia diagnosed via cytologic evaluation of an in vivo, percutaneous ultrasound-guided fine-needle aspirate of affected lung. Additionally, to our knowledge, we offer the first account of the sonographic (pulmonary features of the disease.

  18. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...

  19. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  20. Fluoroscopy-Guided Percutaneous Lung Biopsy: A Valuable Alternative to Computed Tomography

    International Nuclear Information System (INIS)

    Kurban, L.A.; Gomersall, L.; Weir, J.; Wade, P.

    2008-01-01

    Background: Computed tomography (CT) fluoroscopy nowadays is the most preferred method of guidance to perform percutaneous lung biopsy of pulmonary masses. Conventional fluoroscopy is an increasingly forgotten technique that still can be used to perform lung biopsies, with many advantages. Purpose: To compare the accuracy, safety, and effective dose (ED) of conventional fluoroscopy-guided needle lung biopsy (FNLB) with CT-guided needle lung biopsy procedures (CTNLB) reported in the literature. Material and Methods: 100 consecutive patients who underwent FNLB were reviewed retrospectively. Using the final histological diagnoses and the clinical and radiological course of the disease as references, the accuracy and sensitivity of FNLB were calculated. The complication rates of FNLB were assessed. Using computer software (XDOSE), the ED was calculated. The accuracy, complication rates, and the ED of FNLB were compared with CTNLB reported in the literature. Results: The overall accuracy rate and sensitivity of FNLB were both 87%, which are comparable to the range of accuracies reported in the literature for CTNLB (74-97%). The complication rates of FNLB were also comparable to the complication rates reported for CTNLB. The commonest complication was pneumothorax, at a rate of 25%. The ED of FNLB was small, significantly lower than reported in the literature for CT-guided procedures. The mean ED of FNLB was 0.029 mSv, which is approximately equivalent to one chest X-ray. Conclusion: Conventional fluoroscopy is an accurate, safe, and low-dose alternative modality to CT to obtain an image-guided histological diagnosis of pulmonary lesions

  1. Endoscopic ultrasound-guided fine-needle tissue acquisition - A review and update of literature

    Directory of Open Access Journals (Sweden)

    Benjamin Tharian

    2015-01-01

    Full Text Available Ever since the first endoscopic ultrasound-guided fine needle aspiration (FNA was done in 1992, the procedure has evolved to become an indispensable tool for tissue acquisition in patients with gastrointestinal tumors and periluminal lesions. With the growing evidence of neoadjuvant therapy and research into intratumoral therapy, the need to obtain tissue diagnosis for tumors is quite apparent. This review provides an overall perspective to the endosonographer on various issues that are a key for best practices in FNA, in addition to being an update for practicing experienced endosonographers.

  2. Ultrasonography-Guided Fine Needle Aspiration Cytology of Cervical Lymphadenopathy: Comparative Study of the Cytological Adequacy Using of 21- and 23- Gauge Needles

    International Nuclear Information System (INIS)

    Beak, Jin Wook; KIm, Dong Wook; Kim, Bo Mi

    2011-01-01

    To assess the difference in the cytological adequacy of ultrasonography (US)-guided fine needle aspiration cytology (US-FNAC) for cervical lymphadenopathy using 21 and 23 gauge needles. US-FNACs were separately performed on two cervical lymph nodes and in each patient using 21 gauge (group A) and 23 gauge (group B) needles, respectively. We used 4 grade classifications for the cytological analysis of each slide and compared the cytological adequacy of US-FNAC for cervical lymphadenopathy in the two groups. We performed US-FNACs on 58 cervical lymph nodes from 29 patients, with a cytological adequacy of 69.0%. The number of adequate cytological results was 19 (65.5%) in group A and 21 (72.4%) in group B, and the diagnostic adequacy did not differ significantly between the two groups (Mann-Whitney test, p = 0.574). There was no statistically significant difference in the cytological adequacy of US-FNAC for cervical lymphadenopathy according using of 21 and 23 gauge needles.

  3. Feasibility of computed tomography-guided core needle biopsy in producing state-of-the-art clinical management in Chinese lung cancer.

    Science.gov (United States)

    Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long

    2014-03-01

    A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients.

  4. Ultrasound guided fine needle aspiration cytology versus core biopsy in the preoperative assessment of non-palpable breast lesions

    International Nuclear Information System (INIS)

    Ahmed, M.E.; Ahmad, I.

    2010-01-01

    Background: Breast screening is a method of detecting breast cancer at a very early stage. Most of the lesions detected by screening are not malignant. Objective of this study was to compare ultrasound guided fine needle aspiration cytology and core biopsy in the preoperative assessment of non-palpable breast lesions. Methods: The study was conducted prospectively at Department of Radiology, Shaukat Khanum Memorial Cancer Hospital and Research Centre, Pakistan from March 2004 to February 2005. All the patients underwent fine needle aspiration cytology and core biopsy. Later on, all of them had excision biopsy/ mastectomy. Prospectively 80 patients were studied; information was collected on a specifically designed form according to inclusion criteria. The patient age, sex, medical record number and side of lesion were recorded. Clinical history of duration of lump was also taken. Informed consent was obtained. Results: The age of patients were ranges from 20-71 years, with mean of 44.31+- 11.002 and the maximum number of patients 28 (35.3%) was between the ages 50 - 59 years. The sensitivity of FNAC was 92.85%, while the specificity of was 90% and the accuracy rate was 92.1%. The sensitivity of core biopsy was 94.64%, specificity 91.30% and accuracy rate was 94.87%. Conclusion: Fine Needle Aspiration has been found to be an extremely useful method for the diagnosis of lumps of breast. The accuracy and the sensitivity of diagnosis on fine needle aspiration cytology were high. (author)

  5. Accuracy of biopsy needle navigation using the Medarpa system - computed tomography reality superimposed on the site of intervention

    International Nuclear Information System (INIS)

    Khan, M. Fawad; Maataoui, Adel; Gurung, Jessen; Schiemann, Mirko; Vogl, Thomas J.; Dogan, Selami; Ackermann, Hanns; Wesarg, Stefan; Sakas, Georgios

    2005-01-01

    The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54-9.51 mm) and 7.05±1.33 mm for group B (range 4.10-9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique. (orig.)

  6. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping, E-mail: yipingzhuang2010@sina.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Wang, Hai-Yan, E-mail: mycherishgirl@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Jin, E-mail: yari_zj@hotmail.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Feng, Yong, E-mail: fengyong119@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Lei, E-mail: motozl163@163.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China)

    2013-01-15

    Objective: CT-guided transthoracic biopsy is a well-established method in the cytologic or histologic diagnosis of pulmonary lesions. The knowledge of its diagnostic performance and complications for cavitary pulmonary lesions is limited. The purpose of this study was to determine the diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy (FNAB) in cavitary pulmonary lesions. Materials and methods: 102 consecutive patients with pulmonary cavitary lesions received CT-guided FNAB with use of an 18-gauge (n = 35) or 20-gauge (n = 67) Chiba for histology diagnosis. The sensitivity, specificity, and diagnostic accuracy of FNAB were calculated as compared with the final diagnosis. Complications associated with FNAB were observed. The diagnostic accuracy and complications were compared between patients with different lesion sizes and different cavity wall thickness. Results: The overall sensitivity, specificity, and accuracy of FNAB were 96.3%, 98.0%, and 96.1%, respectively. The sensitivity, specificity, and diagnosis accuracy in different lesion size (<2 cm vs ≥2 cm), or different cavity wall thickness (<5 mm vs ≥5 mm) were not different (P > 0.05; 0.235). More nondiagnostic sample was found in wall thickness <5 mm lesions (P = 0.017). Associated complications included pneumothorax in 9 (8.8%) patients and alveolar hemorrhage in 14 patients (13.7%) and hemoptysis in 1 patient (1%). No different rate of complications was found with regard to lesion size, wall thickness, length of the needle path and needle size (P > 0.05). Conclusion: CT-guided FNAB can be effectively ad safely used for patients with pulmonary cavitary lesions.

  7. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel (Dept. of Radiology, Medical Faculty, Univ. Duesseldorf, Duesseldorf (Germany)), email: Patric.Kroepil@med.uni-duesseldorf.de

    2011-10-15

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 +- 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 +- 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 +- 33 vs. n = 126 +- 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  8. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    International Nuclear Information System (INIS)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel

    2011-01-01

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 ± 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 ± 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 ± 33 vs. n = 126 ± 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  9. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  10. Incidental primary mediastinal choriocarcinoma diagnosed by endobronchial ultrasound-guided fine needle aspiration in a patient presenting with transient ischemic attack and stroke.

    Science.gov (United States)

    Francischetti, Ivo M B; Cajigas, Antonio; Suhrland, Mark; Farinhas, Joaquim M; Khader, Samer

    2017-08-01

    We describe a case of a 41-year old male patient with no significant prior medical history who presents with symptoms of Transient Ischemic Attack and stroke. Magnetic Resonance Imaging (MRI) of the brain identified areas of ischemia in the left side, and angiography showed occlusion of the left Medial Cerebral Artery (MCA). Cardiac Transthoracic Echocardiogram (TTE) for stroke evaluation incidentally noted a mediastinal abnormality leading to cancer work-up. Computer Tomography (CT) and 18 F-fluorodeoxyglucose (FDG) PET-CT scan of the chest incidentally revealed an avid 6 cm paraesophagial/subcarinal mass. Further diagnostic work-up with endoscopic and endobronchial ultra sound (EBUS)-guided fine needle aspiration (FNA) of the mass yielded a cytology diagnosis of Germ Cell Tumor (GCT), with choriocarcinoma component. Additionally, high plasma levels of β-human chorionic gonadotrophin (β-HCG) were detected with no evidence of testicular tumor. This exceedingly rare presentation for a primary mediastinal choriocarcinoma underscores the importance of complete investigation of young patients presenting with neurological symptoms compatible with ischemic events. Diagn. Cytopathol. 2017;45:738-743. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. Fine-needle aspirate cytology suggesting hepatic lipidosis in four cats with infiltrative hepatic disease.

    Science.gov (United States)

    Willard, M D; Weeks, B R; Johnson, M

    1999-12-01

    Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.

  12. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  13. Application of B-ultrasonic guided fine needle aspiration cytology in diagnosis of tuberculous lymphadenitis

    International Nuclear Information System (INIS)

    Yu Qi; Yang Jianghui; Li Ning

    2011-01-01

    To explore the value of B-ultrasonic guided fine needle aspiration cytology(FNAC) in the diagnosis of tuberculous lymphadenitis (TB). The patients were carried out FNAC under B-ultrasonic guidance to distinguish the tuberculosis lymphadenitis. With the FNAC diagnosis of lymphoglandulae and reactive hyperplasia lesions of 80 cases, 41 cases were confirmed by histopathology. With FNAC diagnosed tuberculosis 36 cases, granulomatous lymphadenitis 2 cases and reactive hyperplasia 3 cases. FANC is one of efficient method to diagnosis the tuberculous lymphadenitis. This method has some limitations, but it could be overcome by biopsy or polymerase chain reaction. (authors)

  14. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...... of the present study was to evaluate the role of EUS-FNA in isolated mediastinal lymphadenopathy in patients suspected of having tuberculosis....

  15. Use of CT-guided fine needle aspiration biopsy in epidermal growth factor receptor mutation analysis in patients with advanced lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping; Wang, Hai-Yan; Zhang, Jin; Feng, Yong (Dept. of Radiology, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China)), email: yipingzhuang2010@sina.com; Shi, Mei-Qi (Dept. of Chemotherapy, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China))

    2011-12-15

    Background. The safety of using a cutting needle when performing a core-needle biopsy is of major concern, in particular for small lung tumors or tumors near the hilum. Purpose. To investigate the usefulness of CT-guided fine needle aspiration biopsy (FNAB) of the lung in obtaining tumor tissue for epidermal growth factor receptor (EGFR) mutation analysis in advanced lung cancer patients. Material and Methods. Forty-three patients with stage IIIB-IV lung cancer were enrolled. In all patients, CT-guided FNAB was performed using an 18-gauge or 20-gauge Chiba aspiration needle for histology diagnosis and EGFR mutation analysis. Complications associated with CT-guided FNAB were observed, and the specimen mutational assessments were recorded. Results. The obtained tumor samples ranged from 0.5-1.5 cm in length and were adequate for histological and DNA analyses in all patients. No patient had a pneumothorax or hemoptysis. Minor needle tract bleeding appeared in eight patients. Mutation analysis was satisfactorily demonstrated in 23 mutations and 20 non-mutations. Ten and 13 mutations were identified by 18-gauge and 20-gauge needle biopsies, respectively. EFGR mutations, including 12 cases of EGFR exon 19 deletion and 11 cases of exon 21 point mutation, were present in 21 patients with adenocarcinomas, one with squamous cell carcinoma, and one with undifferentiated carcinoma. Conclusion. CT-guided FNAB is a feasible and safe technique for obtaining lung tumor tissues for EGFR gene mutation analysis

  16. Imaging-guided and nonimaging-guided fine needle aspiration of liver lesions: experience with 406 patients.

    Science.gov (United States)

    Edoute, Y; Tibon-Fisher, O; Ben-Haim, S A; Malberger, E

    1991-12-01

    The aim of the present study was to determine the diagnostic accuracy of different modes of fine needle aspiration (FNA) of liver lesions. A total of 492 FNAs were performed on 406 patients in order to confirm or to rule out focal or multifocal neoplastic disease: 29% under ultrasound (US) guidance, 3% with computed tomographic (CT) guidance, 67% preoperatively, and 1% intraoperatively without imaging guidance. Based on histologic, cytologic, and clinical findings, final diagnoses were reached in 387 patients, of whom 264 had malignant liver disease and 123 had benign liver disease. Of 321 aspirations performed in patients with malignant liver disease, the cytologic findings suggested malignancy in 225 (70.1%), suspected malignancy in 25 (7.8%), and did not reveal malignancy in 71 aspirations (22.1%). Among the 123 patients with benign liver disease, the cytologic findings were reported as benign in all but two patients, who had false-positive cytologic findings. The overall sensitivity, specificity, positive, and negative predictive values for cytologic findings were 85.6, 98.4, 99.1, and 76.1%, respectively. The overall diagnostic accuracy was 89.7%. In one patient, fatal intraperitoneal bleeding due to chronic intravascular coagulation complicated the FNA procedure. We conclude that imaging-guided FNA as well as nonguided FNA for cytologic diagnosis of liver lesions are highly accurate and only rarely may be associated with a fatal complication.

  17. Fatal paradoxical pulmonary air embolism complicating percutaneous computed tomography-guided needle biopsy of the lung

    International Nuclear Information System (INIS)

    Chakravarti, Rajesh; Singh, Virendra; Isaac, Rethish; John, Joseph

    2004-01-01

    A 63-year-old man with left upper zone haziness on chest X-ray and an infiltrative lesion with a pleural mass in the left upper lobe on CT scan was scheduled for CT-guided percutaneous trans-thoracic needle biopsy. During the procedure, the patient had massive haemoptysis and cardiorespiratory arrest and could not be revived. Post-mortem CT showed air in the right atrium, right ventricle, pulmonary artery and also in the left atrium and aorta. A discussion on paradoxical air embolism following percutaneous trans-thoracic needle biopsy is presented Copyright (2004) Blackwell Publishing Asia Pty Ltd

  18. Diagnosis of sclerosing hemangioma of lung: Don′t rely on fine-needle aspiration cytology diagnosis alone

    Directory of Open Access Journals (Sweden)

    Kaushik Saha

    2013-01-01

    Full Text Available Sclerosing hemangioma is a rare variety of benign pulmonary neoplasm. It usually presents as asymptomatic, solitary, peripheral, circumscribed lesions in middle-aged women. Here, we describe a 46-year-old woman presenting to us for evaluation of right parahilar lung mass. Previous chest radiography done 10 years back showed a lung mass of almost similar size. Computed Tomography (CT-guided fine-needle aspiration cytology (FNAC was suggestive of adenocarcinoma of lung. A well-circumscribed, capsulated, ovoid mass measuring 5.6 cm × 4 cm × 3 cm, adjacent to the transverse fissure of the right lung was excised by lateral thoracotomy. Histopathological examination along with immunohistochemistry was suggestive of sclerosing hemangioma of lung. A pathologist must consider the clinicoradiological features before coming to a final diagnosis of lung malignancy from FNAC. Whenever there is any confusion regarding lung mass, thoracotomy must be done for arriving at an exact diagnosis from histopathology.

  19. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    International Nuclear Information System (INIS)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens

    2014-01-01

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  20. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    Energy Technology Data Exchange (ETDEWEB)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens, E-mail: macellomaciel@me.com [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil)

    2014-09-15

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  1. Are needles of Pinus pinaster more vulnerable to xylem embolism than branches? New insights from X-ray computed tomography.

    Science.gov (United States)

    Bouche, Pauline S; Delzon, Sylvain; Choat, Brendan; Badel, Eric; Brodribb, Timothy J; Burlett, Regis; Cochard, Hervé; Charra-Vaskou, Katline; Lavigne, Bruno; Li, Shan; Mayr, Stefan; Morris, Hugh; Torres-Ruiz, José M; Zufferey, Vivian; Jansen, Steven

    2016-04-01

    Plants can be highly segmented organisms with an independently redundant design of organs. In the context of plant hydraulics, leaves may be less embolism resistant than stems, allowing hydraulic failure to be restricted to distal organs that can be readily replaced. We quantified drought-induced embolism in needles and stems of Pinus pinaster using high-resolution computed tomography (HRCT). HRCT observations of needles were compared with the rehydration kinetics method to estimate the contribution of extra-xylary pathways to declining hydraulic conductance. High-resolution computed tomography images indicated that the pressure inducing 50% of embolized tracheids was similar between needle and stem xylem (P50 needle xylem  = -3.62 MPa, P50 stem xylem  = -3.88 MPa). Tracheids in both organs showed no difference in torus overlap of bordered pits. However, estimations of the pressure inducing 50% loss of hydraulic conductance at the whole needle level by the rehydration kinetics method were significantly higher (P50 needle  = -1.71 MPa) than P50 needle xylem derived from HRCT. The vulnerability segmentation hypothesis appears to be valid only when considering hydraulic failure at the entire needle level, including extra-xylary pathways. Our findings suggest that native embolism in needles is limited and highlight the importance of imaging techniques for vulnerability curves. © 2015 John Wiley & Sons Ltd.

  2. Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Boris [Goethe University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt (Germany); Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Eichler, Katrin; Siebenhandl, Petra; Gruber-Rouh, Tatjana; Vogl, Thomas Josef; Zangos, Stephan [Goethe University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt (Germany); Czerny, Christoph [Goethe University Hospital, Department of Trauma Surgery, Frankfurt (Germany)

    2013-01-15

    To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle guidance software. A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluoroscopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (n = 20 each). Target distance, needle deviation and time for the procedures were analysed. All phantom interventions (n = 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min). When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories. (orig.)

  3. Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

    International Nuclear Information System (INIS)

    Schulz, Boris; Eichler, Katrin; Siebenhandl, Petra; Gruber-Rouh, Tatjana; Vogl, Thomas Josef; Zangos, Stephan; Czerny, Christoph

    2013-01-01

    To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle guidance software. A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluoroscopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (n = 20 each). Target distance, needle deviation and time for the procedures were analysed. All phantom interventions (n = 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min). When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories. (orig.)

  4. Fine needle aspiration biopsy of pancreas. Cytological assessment

    International Nuclear Information System (INIS)

    Coufal, L.; Heger, L.

    1987-01-01

    The benefits are presented of cytological examination of bioptical material from the pancreas using computerized tomography (CT) or ultrasound. The case is presented of one patient who had repeatedly undergone endoscopy with no results. Only cytological examination of material sampled using fine needle aspiration under CT control helped to immediately diagnose the process. The cytological finding correlated with the histological examination of material later taken during surgery. The problems are discussed of the differential diagnosis of tumors of the pancreas. (author). 5 figs., 9 refs

  5. Computed tomography diagnosis of active bleeding into the thyroid gland.

    Science.gov (United States)

    Veverková, Lucia; Bakaj-Zbrožková, Lenka; Hallamová, Lucie; Heřman, Miroslav

    2013-10-01

    Fine-needle biopsy of the thyroid gland is the most common interventional procedure used to diagnose thyroid diseases. Serious complications are rare in this procedure. They comprise an infection with abscess formation and hemorrhage. To date, only a few case reports have described an ultrasound diagnosis of active bleeding into the thyroid gland. We established such a diagnosis using computed tomography (CT). A 74-year-old woman presented to the emergency department of our hospital with complications after fine-needle biopsy of the thyroid gland. Ultrasound revealed a large hematoma surrounding the gland. A subsequent CT scan confirmed the presence of hematoma and, moreover, showed active bleeding. This finding prompted rapid surgical intervention. CT has the capability to show active bleeding into the thyroid gland.

  6. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens; Universidade Federal do Espirito Santo

    2017-01-01

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  7. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Universidade Federal do Espirito Santo (HUCAM/UFES), Vitoria, ES (Brazil). Hospital Universitario Cassiano Antonio de Morais. Radiologia e Diagnostico por Imagem

    2017-03-15

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  8. Detection of suspicious malignant cervical lymph nodes of unknown origin: diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy with nodal size and central necrosis correlate

    International Nuclear Information System (INIS)

    Lo, C.-P.; Chen, C.-Y.; Chin, S-.C.; Lee, K.-W.; Hsueh, C.-J.; Juan, C.-J.; Kao, H.-W.; Huang, G.-S.

    2007-01-01

    To assess the role of ultrasound-guided fine-needle aspiration biopsy (US-guided FNAB) in the diagnostic workup of suspicious malignant cervical lymph nodes in patients with palpable neck masses and without known primary cancer. The diagnostic accuracy of imaging morphologic criteria, including sizes and central necrosis for assessing suspicious malignant nodes, were also examined. This is a retrospective study of 426 patients with palpable neck masses from an outpatient department evaluated with computed tomography, magnetic resonance imaging, or US. US-guided FNABs were performed in 102 patients with suspicious malignant cervical lymph nodes at a single institution. Cytologically positive lymph nodes (n = 12) were further validated with excisional biopsy. Negative lymph nodes (n = 90) were either excised (n = 10) or followed up by imaging studies for at least one year (n = 80). The diagnostic accuracy of the FNABs along with the imaging findings of nodal sizes and presence of central necrosis, which were classified by a consensus of 2 radiologists, were assessed. Twelve malignant nodes were detected with US-guided FNAB with one false-positive and one false-negative result. The overall sensitivity, specificity, and accuracy for FNAB were 91.7%, 98.9%, and 98.0%. respectively. The sensitivity, specificity, and accuracy were 66.7%, 30.0%, and 34.3% for size criterion and 75.0%, 83.3%, and 82.3% for central necrosis criterion. The size of cervical lymph node does not appear to be an important imaging criterion for assessing suspicious malignant lymph nodes, compared with the criterion of central necrosis. US-guided FNAB is highly specific and sensitive in the diagnostic workup of suspicious malignant cervical lymph nodes in patients without known primary cancers. (author)

  9. Fine needle aspiration cytology of cervicofacial actinomycosis

    Directory of Open Access Journals (Sweden)

    Venkatesh Kusuma

    2008-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Cervicofacial actinomycosis presenting as a fixed jaw swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of cervicofacial actinomycosis diagnosed by fine needle aspiration, along with a review of the relevant literature. A 60 year-old man presented with a gradually increasing 6 x 5 cm swelling in the left side of his jaw. The swelling was fixed, without any apparent sinus or abscess. Fine needle aspiration was diagnostic as it revealed colonies of actinomyces surrounded by polymorphs and chronic inflammatory cells. The histopathological study of the excised specimen confirmed the cytological findings. Fine needle aspiration is an effective tool in the diagnosis of actinomycosis although its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the fine needle aspiration technique.

  10. Cone-beam computed tomography fusion and navigation for real-time positron emission tomography-guided biopsies and ablations: a feasibility study.

    Science.gov (United States)

    Abi-Jaoudeh, Nadine; Mielekamp, Peter; Noordhoek, Niels; Venkatesan, Aradhana M; Millo, Corina; Radaelli, Alessandro; Carelsen, Bart; Wood, Bradford J

    2012-06-01

    To describe a novel technique for multimodality positron emission tomography (PET) fusion-guided interventions that combines cone-beam computed tomography (CT) with PET/CT before the procedure. Subjects were selected among patients scheduled for a biopsy or ablation procedure. The lesions were not visible with conventional imaging methods or did not have uniform uptake on PET. Clinical success was defined by adequate histopathologic specimens for molecular profiling or diagnosis and by lack of enhancement on follow-up imaging for ablation procedures. Time to target (time elapsed between the completion of the initial cone-beam CT scan and first tissue sample or treatment), total procedure time (time from the moment the patient was on the table until the patient was off the table), and number of times the needle was repositioned were recorded. Seven patients underwent eight procedures (two ablations and six biopsies). Registration and procedures were completed successfully in all cases. Clinical success was achieved in all biopsy procedures and in one of the two ablation procedures. The needle was repositioned once in one biopsy procedure only. On average, the time to target was 38 minutes (range 13-54 min). Total procedure time was 95 minutes (range 51-240 min, which includes composite ablation). On average, fluoroscopy time was 2.5 minutes (range 1.3-6.2 min). An integrated cone-beam CT software platform can enable PET-guided biopsies and ablation procedures without the need for additional specialized hardware. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  11. Fine-needle trucut biopsy versus fine-needle aspiration cytology with ultrasound guidance in the abdomen

    International Nuclear Information System (INIS)

    O'Connell, A.M.; Keeling, F.; Given, M.; Logan, M.; Lee, M.J.

    2008-01-01

    Historically, fine-needle aspiration cytology (FNAC) has varying sensitivity, specificity and accuracy in the diagnosis of abdominal lesions with a high insufficient sampling rate. We compared 20-G fine-needle trucut biopsy (FNTB) with FNAC results in the biopsy of solid abdominal tumours. A retrospective review of 171 (128x 20-G FNTB and 43x FNAC) ultrasound-guided biopsies of abdominal tumours on 157 patients (male : female 85:72, mean age 61.25 years) were carried out. One hundred and seventy-one biopsies were carried out: liver 109, pancreas 19, lumph node 10, omentum 5, right iliac fossa mass 6, adrenal 6 and others 16. An average of 2.06 and 1.97 passes (range 1-4) were carried out per FNTB and FNAC, respectively. A definitive diagnosis was made in 122/128 biopsies (95.3%) and 32/43 biopsies (74.4%) for FNTB and FNAC, respectively. Diagnoses consisted of metastatic liver disease (74/171), pancreatic adenocarcinoma (10/171), lymphoma (8/171) and others (33/171) and benign (29/171). No significant complications occurred in either group. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 87, 100, 100, 50, 84.4 and 93.1, 100, 100, 60, 71.4 for FNTB and FNAC, respectively. A greater and more consistent positive diagnosis rate is yielded by 20-G FNTB (95.3%) that FNAC (74.4%). The diagnostic accuracy of FNTB is 84.4% cmopared with 69.8% for FNAC. A greater insufficient sampling rate occurs with FNAC (25.6%) than with FNTB (4.7%). For abdominal biopsy, 20-G FNTB needles have a much higher yield than FNAC with no increase in complications. FNTB is the preferred choice, particularly where cytological assistance at the time of biopsy is unavailable.

  12. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  13. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  14. False Negative Fine Needle Aspiration Biopsy Results in Primary Thyroid Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Joong; Kim, Eun Kyung; Koh, Myoung Ju; Kwak, Jin Young; Moon, Hee Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography-guided fine needle aspiration biopsy (US-FNA) is one of the methods used to diagnose thyroid lymphoma, but it has a relatively high false-negative rate. The authors report a case of a primary thyroid lymphoma associated with underlying lymphocytic thyroiditis that was initially misdiagnosed as lymphocytic thyroiditis based on US-FNA findings

  15. Ultrasound-guided fine needle aspiration of thyroid nodules: A consensus statement by the Korean Society of Thyroid Radiology

    International Nuclear Information System (INIS)

    Lee, Young Hen; Baek, Jung Hwan; Jung, So Lyoung; Kwak, Jin Young; Kim, Ji Hoon; Shin, Jung Hee

    2015-01-01

    Ultrasound (US)-guided fine needle aspiration (US-FNA) has played a crucial role in managing patients with thyroid nodules, owing to its safety and accuracy. However, even with US guidance, nondiagnostic sampling and infrequent complications still occur after FNA. Accordingly, the Task Force on US-FNA of the Korean Society of Thyroid Radiology has provided consensus recommendations for the US-FNA technique and related issues to improve diagnostic yield. These detailed procedures are based on a comprehensive analysis of the current literature and from the consensus of experts.

  16. Contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography in solid pseudopapillary neoplasm of the pancreas

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Lakshmanan, Ramesh Kumar; Sonik, Bhavay; Padmavathy, Rajagopalan; Gunaseelan, Rajamani Emmanuel

    2016-01-01

    Solid pseudopapillary neoplasm (SPN) of the pancreas is a rare pancreatic tumor with low malignant potential. It occurs characteristically more often in young women. Radiological and pathological studies have revealed that the tumor is quite different from other pancreatic tumors. Limited information is available in the literature reporting their accumulation of fluorine- 18 fluorodeoxyglucose ( 18 F-FDG) in positron emission tomography/computed tomography (PET/CT). Here, we report a case of pancreatic SPN imaged with contrast-enhanced FDG PET/CT. A percutaneous fine needle aspiration from the metabolically active lesion revealed SPN, and it was confirmed with histopathological results. Recurrence or metastasis was not found after 7 months of follow-up

  17. Computer tomography guided lung biopsy using interactive breath-hold control

    DEFF Research Database (Denmark)

    Ashraf, Haseem; Krag-Andersen, Shella; Naqibullah, Matiullah

    2017-01-01

    Background: Interactive breath-hold control (IBC) may improve the accuracy and decrease the complication rate of computed tomography (CT)-guided lung biopsy, but this presumption has not been proven in a randomized study. Methods: Patients admitted for CT-guided lung biopsy were randomized...

  18. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    Science.gov (United States)

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  19. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  20. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    Science.gov (United States)

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  1. The Role of Fine Needle Aspiration in the Diagnosis of Parotid Gland Tumors: Correlation With Preoperative Computerized Tomography Tumor Size.

    Science.gov (United States)

    Ghantous, Yasmine; Naddaf, Raja; Barak, Michal; Abd-Elraziq, Murad; Abu Eln-Naaj, Imad

    2016-03-01

    The role of fine needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses is still controversial, regarding its sensitivity and specificity that vary between 41% and 100% and between 86% and 100% respectively.The aim of this study was to identify the specificity and sensitivity of FNAC of parotid gland tumors in relation to the tumor size as characterized preoperatively by computer tomography. The medical files of 79 patients whom were referred to the MaxilloFacila Surgery Department, Rambam medical center, over a 10.5-year period (2000-2010) were analyzed retrospectively.The extensity of the operation was determined by the location of the tumor as presented in computed tomography (CT) radiography, and preoperative FNAC examination.The majority of the masses were located in the superficial lobe (88.52%), and only 11.48% of the patients were located in the deep lobe (8:1 ratio). FNAC results were nondiagnostic in 7 patients (8.86%), 62 patients were diagnosed as inflammatory and benign lesion in (78.48%), malignant tumors were diagnosed in 10 patients (12.65%).The sensitivity in our study was 90%, the specificity was 98%, positive predictive value was 90%, negative predictive value was 98%, and diagnostic accuracy was 88%. The positive predictive value was 90%, the negative predictive value was 98%.Analyzing the effect of the preoperative CT size upon the accuracy of the FNAC diagnosis, we found that lesion with preoperative CT size greater than 24 mm has a more accurate FNAC result (P = 0.034).

  2. Primary neuroendocrine carcinoma of breast with liver and bone metastasis detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshak; Shibu, Deepu; Radhakrishnan, Edathuruthy Kalarikal; Shinto, Ajit Sugunan

    2014-01-01

    Cases of primary neuroendocrine carcinoma (NEC) of the breast have been reported, though rare. We report the case of a 45-year-old woman presented with jaundice and evaluated to have liver metastasis from neuroendocrine origin. She underwent whole body positron emission tomography/computed tomography, which showed left breast lesion and bone metastasis. Fine-needle aspiration (FNA) of breast revealed a NEC. A diagnosis of a primary NEC of the breast was rendered with hepatic and bone metastasis. She was treated with peptide receptor radionuclide therapy and is on follow-up

  3. Ultrasonography-guided core needle biopsy for the thyroid nodule: does the procedure hold any benefit for the diagnosis when fine-needle aspiration cytology analysis shows inconclusive results?

    Science.gov (United States)

    Hahn, S Y; Han, B-K; Ko, E Y; Ko, E S

    2013-01-01

    Objective: We evaluated the diagnostic role of ultrasonography-guided core needle biopsy (CNB) according to ultrasonography features of thyroid nodules that had inconclusive ultrasonography-guided fine-needle aspiration (FNA) results. Methods: A total of 88 thyroid nodules in 88 patients who underwent ultrasonography-guided CNB because of previous inconclusive FNA results were evaluated. The patients were classified into three groups based on ultrasonography findings: Group A, which was suspicious for papillary thyroid carcinoma (PTC); Group B, which was suspicious for follicular (Hurthle cell) neoplasm; and Group C, which was suspicious for lymphoma. The final diagnoses of the thyroid nodules were determined by surgical confirmation or follow-up after ultrasonography-guided CNB. Results: Of the 88 nodules, the malignant rate was 49.1% in Group A, 12.0% in Group B and 90.0% in Group C. The rates of conclusive ultrasonography-guided CNB results after previous incomplete ultrasonography-guided FNA results were 96.2% in Group A, 64.0% in Group B and 90.0% in Group C (p=0.001). 12 cases with inconclusive ultrasonography-guided CNB results were finally diagnosed as 8 benign lesions, 3 PTCs and 1 lymphoma. The number of previous ultrasonography-guided FNA biopsies was not significantly different between the conclusive and the inconclusive result groups of ultrasonography-guided CNB (p=0.205). Conclusion: Ultrasonography-guided CNB has benefit for the diagnosis of thyroid nodules with inconclusive ultrasonography-guided FNA results. However, it is still not helpful for the differential diagnosis in 36% of nodules that are suspicious for follicular neoplasm seen on ultrasonography. Advances in knowledge: This study shows the diagnostic contribution of ultrasonography-guided CNB as an alternative to repeat ultrasonography-guided FNA or surgery. PMID:23564885

  4. The Utility of Endoscopic Ultrasound Guided Fine Needle Aspiration in the Diagnosis of Infectious Diseases—Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Mauro Ajaj Saieg

    2013-01-01

    Full Text Available Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA is a fast and minimally invasive methodology with a crucial impact on patients’ management. It has an important and established role in the diagnosis and staging of mediastinal and abdominal malignancies, but little is discussed in the literature on the usefulness of this technique in the diagnosis of infectious diseases. In the current report, we present three different cases where EUS was essential for reaching the diagnosis of tuberculosis and paracoccidiodomicosis in cases otherwise seen as malignant. In conclusion, EUS was successful not only in obtaining enough cells for morphological analysis, but also for the production of cell blocks and assessment of the presence of the microorganisms by special stains. EUS allied to fine needle biopsy was an important tool in determining diagnoses of enlarged lymph nodes, revealing the diagnosis of infectious diseases in cases otherwise seen as malignant. The wide use of this methodology in cases such as those reported here cannot only rule out malignancy, but also aid critically ill patients by installing early proper therapy without the need for aggressive interventions.

  5. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  6. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  7. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  8. Computed tomography guided navigation assisted percutaneous ablation of osteoid osteoma in a 7-year-old patient: the low dose approach

    Energy Technology Data Exchange (ETDEWEB)

    Krokidis, Miltiadis; Tappero, Carlo; Bogdanovic, Daniel; Stamm, Anna-Christina [Inselspital, Bern University Hospital, Department of Diagnostic, Interventional and Pediatric Radiology, Bern (Switzerland); Ziebarth, Kai [Inselspital, Bern University Hospital, Department of Pediatric Surgery, Bern (Switzerland)

    2017-07-15

    Osteoid osteoma (OO) is a benign tumour that can cause severe pain and functional limitation to children and young adults; the treatment of choice is image-guided ablation. Due to the very small size of the lesion, detection and accurate needle placement may be challenging. Computed tomography (CT) offers very detailed imaging of the skeleton and is the modality of choice for the detection of small OO and for ablation guidance. Nevertheless, CT-guided positioning of the ablation applicator is linked to significant radiation exposure, particularly for the paediatric population. This case describes the successful use of a novel CT-based navigation system that offers the possibility of accurate ablation with only minimal radiation exposure in a paediatric patient. (orig.)

  9. Investigation of tissue cellularity at the tip of the core biopsy needle with optical coherence tomography.

    Science.gov (United States)

    Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H

    2018-02-01

    We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.

  10. Comparison of Fine Needle Aspiration and Fine Needle Nonaspiration Cytology of Thyroid Nodules: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Hongming Song

    2015-01-01

    Full Text Available Background. Fine needle aspiration cytology (FNAC and fine needle nonaspiration cytology (FNNAC are useful cost-effective techniques for preoperatively assessing thyroid lesions. Both techniques have advantages and disadvantages, and there is controversy over which method is superior. This meta-analysis was performed to evaluate the differences between FNAC and FNNAC for diagnosis of thyroid nodules. Methods. Primary publications were independently collected by two reviewers from PubMed, Web of Science, Google Scholar, EBSCO, OALib, and the Cochrane Library databases. The following search terms were used: fine needle, aspiration, capillary, nonaspiration, sampling without aspiration, thyroid, and cytology. The last search was performed on February 1, 2015. Results. Sixteen studies comprising 1,842 patients and 2,221 samples were included in this study. No statistically significant difference was observed between FNAC and FNNAC groups with respect to diagnostically inadequate smears, diagnostically superior smears, diagnostic performance (accuracy, sensitivity, specificity, negative predictive value, and positive predictive value, area under the summary receiver operating characteristic curve, average score of each parameter (background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture, and total score of five parameters. Conclusion. FNAC and FNNAC are equally useful in assessing thyroid nodules.

  11. Metastatic Chordoma: A Diagnostic Challenge on Fine Needle Aspiration

    Directory of Open Access Journals (Sweden)

    Ghassan Tranesh

    2016-01-01

    Full Text Available Chordomas are primary low grade malignant tumors of bone that usually arise within both ends of axial skeleton. The Notochord is a midline, ectoderm-derived structure that defines the phylum of chordates. Chordomas may pose difficult diagnostic challenges when encountered in secondary locations, such as lungs or other parenchymatous organs. We report the cytologic findings of a metastatic chordoma sampled through CT-scan guided fine needle aspiration (FNA of lower lobe lung nodule in a 54-year-old man diagnosed with recurrent chordoma involving the lumber spine and paraspinal region.

  12. Augmented Reality-Guided Lumbar Facet Joint Injections.

    Science.gov (United States)

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  13. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  14. Computed tomography-guided percutaneous catheter drainage of primary and secondary iliopsoas abscesses

    International Nuclear Information System (INIS)

    Cantasdemir, M.; Kara, B.; Cebi, D.; Selcuk, N.D.; Numan, F.

    2003-01-01

    AIM: To report our experience with computed tomography (CT)-guided percutaneous catheter drainage (PCD) of iliopsoas abscesses. MATERIALS AND METHODS: Twenty-two iliopsoas abscesses in 21 patients (11 women, 10 men) aged between 18 and 66 years (mean 36 years) were treated with PCD. Abdominal CT demonstrated the iliopsoas abscesses, which were definitively determined by Gram staining and aspirate cultures. Twenty of the 22 iliopsoas abscesses were primary and two were secondary. All PCD procedures were performed under local anaesthesia using a single-step trocar technique (n=19) or Seldinger technique (n=3). RESULTS: PCD was an effective treatment in 21 out of the 22 iliopsoas abscesses. Recurrence was seen in three abscesses as minimal residual collections. Two of them resolved spontaneously with anti-tuberculous regimen. One required percutaneous needle aspiration. The procedure failed in a diabetic patient with a secondary abscess, who died due to sepsis. The length of time that catheters remained in place ranged from 21 to 75 days (mean 59.7 days). Complications included catheter dislocation in four abscesses, which required removal of dislocated catheters and indwelling new ones. CONCLUSION: CT-guided PCD is a safe and effective front-line treatment of iliopsoas abscesses. Surgery should be reserved for failure of PCD and presence of contraindications to PCD

  15. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  16. CT guided transthoracic fine needle aspiration biopsy (TFNAB) of the chest tumours; Transtorakalna biopsja aspiracyjna cienkoiglowa (TBAC) guzow umiejscowionych w klatce piersiowej pod kontrola obrazu tomografii komputerowej

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, J; Legaszewski, T; Skrzelewski, S; Sraga, W [Katedra i Zaklad Radiologii Lekarskiej i Radiodiagnostyki, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Zajecki, W [Katedra i Klinika Chirurgii Klatki Piersiowej, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Harasim, J [Katedra i Zaklad Patomorfologii, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Polonska, A [Katedra i Klinika Fizjopneumonologii, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland

    2003-07-01

    Tumours spreading within the chest are nowadays diagnosed based on computed tomography (CT). The aim of this paper is to present a few years experience in transthoracic fine needle aspiration biopsy of lung tumours and tumour-like lesions in adjacent tissues and organs during CT examination. To make an accurate diagnosis, the authors performed 124 TFNAB in 116 patients. About 2/3 of the biopsies were performed in patients with a tumour size from 1 to 5 cm in diameter, adjacent or located peripherally to the chest wall. The valuable cellular material, which enabled us to define a type of a disease and to make a final clinical diagnosis, was obtained in nearly 80% of cases. The complications were found in 10 patients (8.6% of all patients). Pneumothorax was found in eight cases and pulmonary bleeding (bleeding into pulmonary parenchyma and bleeding from respiratory duct) in two cases. The authors emphasized the significance of TFNAB in obtaining valuable material for fine spectrum study and discussed the problem of safety related to this procedure. (author)

  17. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    Science.gov (United States)

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  18. Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery.

    Science.gov (United States)

    Watanabe, E; Watanabe, T; Manaka, S; Mayanagi, Y; Takakura, K

    1987-06-01

    A new device was invented as an adjunct for computed tomography (CT)-guided stereotaxic or open neurosurgery. It is composed of a multijoint three-dimensional digitizer (sensor arm) and a microcomputer, which indicates the place of the sensor arm tip on preoperative CT images. Computed tomography scan is performed preoperatively with three markers placed on the nasion and ears. At surgery, after fixing the patient's head and the sensor arm, sampling of the standard points was done to translate the position of the tip of the sensor arm onto the CT images displayed on a computer screen. In this way positional data from conventional preoperative CT scan can be directly transferred into the surgical field. This system has the unique feature of introducing CT-guided stereotaxis into conventional open neurosurgery.

  19. Endobronchial ultrasound-guided transbronchial needle aspiration for systematic nodal staging of lung cancer in patients with N0 disease by computed tomography and integrated positron emission tomography-computed tomography.

    Science.gov (United States)

    Ong, Philip; Grosu, Horiana; Eapen, George A; Rodriguez, Macarena; Lazarus, Donald; Ost, David; Jimenez, Carlos A; Morice, Rodolfo; Bandi, Venkata; Tamara, Luis; Cornwell, Lorraine; Green, Linda; Zhu, Angela; Casal, Roberto F

    2015-03-01

    Data regarding the sensitivity of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for staging of lung cancer in patients with radiographic N0 disease is scant and inconsistent. With increasing use of nonoperative ablative therapies, studies focusing on the performance characteristics of EBUS-TBNA in this population are important. To evaluate the sensitivity and negative predictive value (NPV) of EBUS-TBNA in patients with non-small cell lung cancer and radiographic N0 disease both by computed tomography (CT) and positron emission tomography (PET)-CT. This was a retrospective review of EBUS-TBNA performed for lung cancer staging at two major academic centers from 2009 to 2014. Patients with radiographic N0 disease (lymph nodes [LN]≤1 cm in the short axis and maximum standardized uptake value≤2.5 by PET-CT) were included. Primary outcome was sensitivity and NPV of EBUS-TBNA. Two hundred twenty patients with radiographic N0 disease underwent EBUS-TBNA, and 734 LN were sampled (median 3, range 1-6). Median LN diameter was 0.72 cm. One hundred patients (45.5%) underwent surgery, and 120 patients (54.5%) had nonsurgical therapy. N status was up-staged in 49 patients (22.3%): 18 by EBUS-TBNA (N1=11, N2=6, N3=1), 27 by surgery (N1 intralobar=16, N1 extralobar=3, N2=8 [5 LN in stations 4 and 7, and 3 LN in stations 5-6), and 4 by imaging follow-up (N1=2, N2=2). Overall false-negative rate of EBUS was 14.1% (sensitivity, 36.7%; specificity, 100%; and NPV, 84.7%). False-negative rate was 27 and 3.3% in surgical and nonsurgical populations, respectively. Excluding patients with occult disease "outside" the reach of EBUS, the overall false-negative rate of EBUS-TBNA was 5.5% (sensitivity, 60%; specificity, 100%; and NPV, 93.4%). This is the largest report of EBUS-TBNA in patients with N0 disease by "integrated" PET-CT. The majority of false-negative EBUS results were in LN stations outside its reach. In our study, both sensitivity and NPV of

  20. Should fine needle aspiration cytology in breast assessment be abandoned?

    International Nuclear Information System (INIS)

    Litherland, Janet C.

    2002-01-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  1. Does obesity preclude lumbar puncture with a standard spinal needle? The use of computed tomography to measure the skin to lumbar subarachnoid space distance in the general hospital population.

    LENUS (Irish Health Repository)

    Halpenny, Darragh

    2013-06-05

    OBJECTIVES: Failed lumbar puncture (LP) is a common indication for referral for radiologically guided LP. This study aims to evaluate what percentage of the hospital population would fail an LP using a standard 9-cm needle because of obesity and a skin to subarachnoid space distance greater than 9 cm. METHODS: Images of 402 consecutive patients undergoing computed tomography of the abdomen and pelvis were reviewed. Skin to subarachnoid space distance was calculated using sagittal images. A survey was conducted among junior hospital doctors to assess their experience of performing lumbar puncture in obese patients. RESULTS: Four hundred patients were included. Fifty-five patients (13.8 %) had a skin to subarachnoid space distance greater than 9 cm. Intra-abdominal fat, subcutaneous fat and abdominal girth correlated with distance between the skin and subarachnoid space. Among junior doctors, 68.3 % (n = 41) reported LP failure on an obese patient; 78.4 % (n = 47) were unaware of the existence of a longer needle and 13.3 % (n = 8) had experience using a longer needle. CONCLUSIONS: A significant proportion of the hospital population will fail LP with a standard length spinal needle. Selecting a longer needle may be sufficient to successfully complete LP in obese patients. KEY POINTS : • Lumbar puncture failure commonly leads to referral for an image-guided procedure • Standard lumbar puncture may fail in 13.8 % of patients due to obesity • 78.4 % of trainee doctors are unaware of the existence of longer spinal-needles • Using longer spinal needles may allow successful LP in obese patients.

  2. Development of a guidance guide for dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Fontes, Ladyjane Pereira

    2016-01-01

    Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR. (author)

  3. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  4. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  6. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  7. Fine needle diagnosis in lumbar osteomyelitis

    International Nuclear Information System (INIS)

    Joshi, K.B.; Brinker, R.A.

    1983-01-01

    Lumbar vertebral body and disk infection, presenting as low back pain, is a relatively uncommon disease but is seen more often in drug addicts. Radiographs show typical changes of infection of the lumbar vertebrae and adjacent disc. Under local anesthesia a fine needle is placed, saline injected, and aspirated. The entire needle-syringe unit is submitted to the bacteriology department. Pseudomonas infection is usually found. This method of diagnosis is simple, cost effective, well accepted by the patients, and can be done on outpatients. (orig.)

  8. Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Hirose, Takashi; Mori, Kiyoshi; Machida, Suguru; Tominaga, Keigo; Yokoi, Kohei; Adachi, Mitsuru

    2000-01-01

    The purpose of this study was to evaluate the usefulness of computed tomographic (CT) fluoroscopy-guided transthoracic needle biopsy (TTNB) with an 18-gauge automatic biopsy gun for the diagnosis of pulmonary nodules. Between March 1996 and January 1998, 50 patients in whom pulmonary lesions could not be diagnosed cytopathologically with fiberoptic bronchoscopy or were not clearly visualized with fluoroscopy underwent CT fluoroscopy-guided TTNB. Final pathological diagnoses were 23 lung carcinomas, five pulmonary metastases and 22 benign lesions. Sufficient tissue for analysis was obtained from 48 of the 50 lesions (96%). The overall diagnostic yield of CT fluoroscopy-guided TTNB was 90%. The sensitivity, specificity and accuracy for malignancy were 89%, 100% and 94%, respectively. In 20 of the 22 cases (91%) of benign lesions, histological analysis yielded correct and specific diagnoses. Complications occurred in 22 of the 50 cases (44%). The most common complication was pneumothorax, which occurred in 21 of the 50 cases (42%). Chest tube insertion was required in 6 (12%). Although CT fluoroscopy could not decrease the complication rate, CT fluoroscopy-guided TTNB with an automatic biopsy gun appears to be a promising technique for diagnosing pulmonary lesions, particularly benign lesions. (author)

  9. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    Science.gov (United States)

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  10. The diagnostic value of thyroglobulin concentration in fine-needle aspiration of the cervical lymph nodes in patients with differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Mikosinski, S.; Oszukowska, L.; Makarewicz, J.; Adamczewski, Z.; Lewinski, A.; Pomorski, L.; Sporny, S.

    2006-01-01

    Introduction: Recurrent differentiated thyroid cancer generally occurs first in the neck. Ultrasound is sensitive in detecting enlarged cervical lymph nodes but is not specific enough. Ultrasound-guided fine-needle biopsy increases the specificity but still may fail to detect a recurrence of the disease in the cystic metastatic lymph nodes. The aim of the study was to estimate the value of Tg concentration in the needle washout after fine-needle aspiration of suspicious lymph nodes. Material and methods: The 105 patients studied had presented one or more enlarged suspicious cervical lymph nodes. All had undergone total thyroidectomy and 131I ablative therapy. Serum thyroglobulin (Tg) concentration was within the 0.15 - 711.5 ng/ml range (mean 22.24 ng/ml) and Tg recovery range 94 - 100%. The positive Tg washout concentration cut-off value was established as equal to the mean plus two standard deviations of the Tg washout concentration of patients with negative cytology. Results: Lymph node involvement was diagnosed by cytology in 15 patients and in 28 lymph nodes. Positive Tg washout concentration was found in 22 patients and in 48 lymph nodes. All the lymph nodes which turned out to have positive cytology had a positive Tg washout concentration. All lymph nodes with positive cytology were positive in pathology. Seven patients and 20 lymph nodes with negative cytology were positive in the Tg washout concentration test. All but one patients and all but two lymph nodes with a positive Tg washout concentration had positive pathology. Conclusions: 1. Ultrasound-guided fine-needle biopsy is not sensitive enough to detect all metastatic lymph nodes. 2. The Tg washout concentration test is 100% sensitive in the detection of metastatic lymph nodes. 3. Cytology in ultrasound- guided fine-needle biopsy is 100% specific. 4. The Tg washout concentration test carries a risk of false-positive results. 5. Both methods should be used for early detection of metastatic lymph nodes

  11. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    Science.gov (United States)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  12. Extrapulmonary tuberculosis: Fine needle aspiration cytology ...

    African Journals Online (AJOL)

    Patients and Methods: This is a consecutive 9-year analysis of patients with peripheral lymphadenopathy. All the patients had fine needle aspiration. Smears were made, fixed in 95% alcohol and stained with hematoxylin and eosin and Zeihl Neelsen stains. Results: 48 patients, 31 males and 17 females, were analyzed.

  13. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  14. Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2014-01-01

    Aim: To evaluate the factors influencing diagnostic yield of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for bone lesions. Materials and methods: Between September 2005 and July 2011, 162 consecutive CT-guided CNB procedures were performed in 155 patients. The variables analysed were age, sex, lesion location, lesion type, lesion size, specimen size, biopsy needle gauge, and individual radiologist. The factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were determined by multivariate analysis of variables. Results: The diagnostic yield was 81.5%. Diagnostic yield was 89.9% for lytic bone lesions and 48.5% for sclerotic bone lesions (p < 0.001), and 89.2% for lesions ≥3 cm and 73.4% for lesions <3 cm (p = 0.010). The significant factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were lesion type [p < 0.001; odds ratio (OR) for a lytic lesion was approximately 12 times higher than that for a sclerotic lesion; 95% confidence interval (CI): 4.22–34.01], and lesion size (p = 0.012; OR for a lesion size ≥3 cm was about five-times higher than that for a lesion size <3 cm; 95% CI: 1.42–16.71). Conclusion: Lesion type and lesion size are determining factors in diagnostic yield. The higher diagnostic yield is correlated with lytic lesion and lesion size ≥3 cm

  15. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  16. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  17. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  18. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture?

    International Nuclear Information System (INIS)

    Kim, Dong Wook; Rho, Myung Ho; Kim, Ki Nam

    2009-01-01

    This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was

  19. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    2016-07-27

    Jul 27, 2016 ... The different types of non-surgical breast biopsy procedures include: fine needle aspiration biopsy. (FNAB), core needle ... needle biopsies of breast lesions at a regional public hospital in ..... NCR_2009_FINAL.pdf. 2. Parikh J ...

  20. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  1. Enabling image fusion for a CT guided needle placement robot

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.

    2017-03-01

    Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.

  2. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    International Nuclear Information System (INIS)

    Koethe, Yilun; Xu, Sheng; Velusamy, Gnanasekar; Wood, Bradford J.; Venkatesan, Aradhana M.

    2014-01-01

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  3. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Koethe, Yilun [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Duke University School of Medicine, Durham, NC (United States); Xu, Sheng [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); Velusamy, Gnanasekar [Perfint Healthcare Pvt. Ltd., Chennai (India); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Venkatesan, Aradhana M. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States)

    2014-03-15

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  4. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  5. Fibroadenoma: can fine needle aspiration biopsy avoid short term follow-up?

    Science.gov (United States)

    Leconte, I; Abraham, C; Galant, C; Sy, M; Berlière, M; Fellah, L

    2012-10-01

    To confirm whether fine needle aspiration biopsy (FNAB) can avoid close monitoring, a source of worry for women patients with a suspected fibroadenoma found by ultrasound, and requiring their compliance. Over 39months, 427 nodules with a diagnosis of fibroadenoma were sampled in 372 patients using ultrasound-guided FNAB. The sonographic appearance of all the nodules suggested BI-RADS category 3 fibroadenomas. The mean size of the fibroadenomas was 9mm. The mean duration of follow-up was 29.7months. Seven nodules had atypical cytology: a microbiopsy and/or excision found a simple fibroadenoma (n=3), mastitis (n=1), a fibroadenoma associated with a papilloma (n=1), fibrosis (n=1) and normal tissue (n=1). Seven other nodules were resected during treatment for synchronous cancer, and were diagnosed as fibroadenomas. Two hundred and seventy-six nodules were followed-up (121 patients were lost to follow-up [n=132]) and the appearance of 263 nodules (95.29%) was stable. Seven nodules, which had increased in size, underwent another FNAB or microbiopsy or surgery. Five nodules were not found again. The borders of one nodule showed modifications. The use of fine needle aspiration biopsy, interpreted by an experienced cytologist, means that short term follow-up of fibroadenomas can be avoided. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  6. Nodular fasciitis of the face diagnosed by US-guided core needle biopsy: a case report

    International Nuclear Information System (INIS)

    Lee, Sang Kwon; Kwon, Sun Young

    2006-01-01

    We report here on a case of nodular fasciitis (NF) that was diagnosed by ultrasonography (US)-guided core needle biopsy in a 31-year-old man, and we include the US and computed tomographic (CT) findings and the histopathologic findings at US-guided core needle biopsy (CNB). We suggest that high-resolution US is useful for the detailed evaluation of NF in the superficial regions, such as the face, and US-guided CNB is useful for the definitive histologic diagnosis of NF without causing scarring

  7. Extramedullary plasmacytoma. Fine needle aspiration findings.

    Science.gov (United States)

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  8. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    Science.gov (United States)

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  9. Diagnosis of invasive aspergillus tracheobronchitis facilitated by endobronchial ultrasound-guided transbronchial needle aspiration: a case report

    Directory of Open Access Journals (Sweden)

    Casal Roberto F

    2009-11-01

    Full Text Available Abstract Introduction Invasive pulmonary aspergillosis is the most common form of infection by Aspergillus species among immunocompromised patients. Although this infection frequently involves the lung parenchyma, it is unusual to find it limited to the tracheobronchial tree, a condition known as invasive aspergillus tracheobronchitis. Case presentation A 65 year-old Hispanic man from Bolivia with a history of chronic lymphocytic leukemia developed cough and malaise eight months after having an allogenic stem cell transplant. A computed tomography of the chest revealed an area of diffuse soft tissue thickening around the left main stem bronchus, which was intensely fluorodeoxyglucose-avid on positron emission tomography scanning. An initial bronchoscopic exam revealed circumferential narrowing of the entire left main stem bronchus with necrotic and friable material on the medial wall. Neither aspirates from this necrotic area nor bronchial washing were diagnostic. A second bronchoscopy with endobronchial ultrasound evidenced a soft tissue thickening on the medial aspect of the left main stem bronchus underlying the area of necrosis visible endoluminally. Endobronchial ultrasound-guided transbronchial needle aspiration performed in this area revealed multiple fungal elements suggestive of Aspergillus species. Conclusion We describe the first case of invasive aspergillus tracheobronchitis in which the diagnosis was facilitated by the use of endobronchial ultrasound guided trans-bronchial needle aspiration. To the best of our knowledge, we are also presenting the first positron emission tomography scan images of this condition in the literature. We cautiously suggest that endobronchial ultrasound imaging may be a useful tool to evaluate the degree of invasion and the involvement of vascular structures in these patients prior to bronchoscopic manipulation of the affected areas in an effort to avoid potentially fatal hemorrhage.

  10. Clinical impact of endoscopic ultrasound-guided fine needle aspiration biopsy in patients with upper gastrointestinal tract malignancies. A prospective study

    DEFF Research Database (Denmark)

    Mortensen, M B; Pless, T; Durup, J

    2001-01-01

    BACKGROUND AND STUDY AIMS: Several studies have evaluated the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) in the upper gastrointestinal tract, but so far no studies have specifically evaluated the clinical impact of EUS-FNAB in upper gastrointestinal tract......% in esophageal, gastric, and pancreatic cancer, respectively. The staging-related clinical impact was similar for all three types of cancer (11-12.5%), whereas the diagnosis-related impact was highest in pancreatic cancer patients (86%). EUS-FNAB was inadequate in 13% and gave false-negative results in 5......%. The overall sensitivity, specificity and accuracy for EUS-FNAB were 80%, 78% and 80%, respectively. No complications related to the biopsy procedure were seen. CONCLUSIONS: If EUS-FNAB was performed only in cases where a positive malignant result would change patient management, then approximately one out...

  11. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Oda, Miyo; Ito, Katsuhide

    2010-09-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: "none", "mild", "moderate" and "severe". The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p < 0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax.

  12. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method

    International Nuclear Information System (INIS)

    Kakizawa, Hideaki; Hieda, Masashi; Oda, Miyo; Toyota, Naoyuki; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Ito, Katsuhide

    2010-01-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: 'none', 'mild', 'moderate' and 'severe'. The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p<0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax. (author)

  13. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    NARCIS (Netherlands)

    Konge, L.; Vilmann, P.; Clementsen, P.; Annema, J. T.; Ringsted, C.

    2012-01-01

    Background and study aims: Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was

  14. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT

    International Nuclear Information System (INIS)

    Chami, H.A.; Faraj, W.; Yehia, Z.A.; Badour, S.A.; Sawan, P.; Rebeiz, K.; Safa, R.; Saade, C.; Ghandour, B.; Shamseddine, A.; Mukherji, D.; Haydar, A.A.

    2015-01-01

    Aim: To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. Materials and methods: One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below −950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Results: Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01–1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Conclusion: Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. - Highlights: • Examine the association between quantitative emphysema measures & post NLB pneumothorax. • The risk of post-NLB pneumothorax increases with every unit increase in percent emphysema. • Percent emphysema is a significant predictor of pneumothorax post transthoracic NLB. • Quantitative analysis of chest CT offers clinicians' objective measures to assess pneumothorax risk.

  15. [Fluoroscopy dose reduction of computed tomography guided chest interventional radiology using real-time iterative reconstruction].

    Science.gov (United States)

    Hasegawa, Hiroaki; Mihara, Yoshiyuki; Ino, Kenji; Sato, Jiro

    2014-11-01

    The purpose of this study was to evaluate the radiation dose reduction to patients and radiologists in computed tomography (CT) guided examinations for the thoracic region using CT fluoroscopy. Image quality evaluation of the real-time filtered back-projection (RT-FBP) images and the real-time adaptive iterative dose reduction (RT-AIDR) images was carried out on noise and artifacts that were considered to affect the CT fluoroscopy. The image standard deviation was improved in the fluoroscopy setting with less than 30 mA on 120 kV. With regard to the evaluation of artifact visibility and the amount generated by the needle attached to the chest phantom, there was no significant difference between the RT-FBP images with 120 kV, 20 mA and the RT-AIDR images with low-dose conditions (greater than 80 kV, 30 mA and less than 120 kV, 20 mA). The results suggest that it is possible to reduce the radiation dose by approximately 34% at the maximum using RT-AIDR while maintaining image quality equivalent to the RT-FBP images with 120 V, 20 mA.

  16. Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique

    International Nuclear Information System (INIS)

    Motamedi, Kambiz; Levine, Benjamin D.; Seeger, Leanne L.; McNitt-Gray, Michael F.

    2014-01-01

    To evaluate the success rate of a low-dose (50 % mAs reduction) computed tomography (CT) biopsy technique. This protocol was adopted based on other successful reduced-CT radiation dose protocols in our department, which were implemented in conjunction with quality improvement projects. The technique included a scout view and initial localizing scan with standard dose. Additional scans obtained for further guidance or needle adjustment were acquired by reducing the tube current-time product (mAs) by 50 %. The radiology billing data were searched for CT-guided musculoskeletal procedures performed over a period of 8 months following the initial implementation of the protocol. These were reviewed for the type of procedure and compliance with the implemented protocol. The compliant CT-guided biopsy cases were then retrospectively reviewed for patient demographics, tumor pathology, and lesion size. Pathology results were compared to the ultimate diagnoses and were categorized as diagnostic, accurate, or successful. Of 92 CT-guided procedures performed during this period, two were excluded as they were not biopsies (one joint injection and one drainage), 19 were excluded due to non-compliance (operators neglected to follow the protocol), and four were excluded due to lack of available follow-up in our electronic medical records. A total of 67 compliant biopsies were performed in 63 patients (two had two biopsies, and one had three biopsies). There were 32 males and 31 females with an average age of 50 (range, 15-84 years). Of the 67 biopsies, five were non-diagnostic and inaccurate and thus unsuccessful (7 %); five were diagnostic but inaccurate and thus unsuccessful (7 %); 57 were diagnostic and accurate thus successful (85 %). These results were comparable with results published in the radiology literature. The success rate of CT-guided biopsies using a low-dose protocol is comparable to published rates for conventional dose biopsies. The implemented low-dose protocol

  17. Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique

    Energy Technology Data Exchange (ETDEWEB)

    Motamedi, Kambiz; Levine, Benjamin D.; Seeger, Leanne L.; McNitt-Gray, Michael F. [UCLA Health System, Radiology, Los Angeles, CA (United States)

    2014-11-15

    To evaluate the success rate of a low-dose (50 % mAs reduction) computed tomography (CT) biopsy technique. This protocol was adopted based on other successful reduced-CT radiation dose protocols in our department, which were implemented in conjunction with quality improvement projects. The technique included a scout view and initial localizing scan with standard dose. Additional scans obtained for further guidance or needle adjustment were acquired by reducing the tube current-time product (mAs) by 50 %. The radiology billing data were searched for CT-guided musculoskeletal procedures performed over a period of 8 months following the initial implementation of the protocol. These were reviewed for the type of procedure and compliance with the implemented protocol. The compliant CT-guided biopsy cases were then retrospectively reviewed for patient demographics, tumor pathology, and lesion size. Pathology results were compared to the ultimate diagnoses and were categorized as diagnostic, accurate, or successful. Of 92 CT-guided procedures performed during this period, two were excluded as they were not biopsies (one joint injection and one drainage), 19 were excluded due to non-compliance (operators neglected to follow the protocol), and four were excluded due to lack of available follow-up in our electronic medical records. A total of 67 compliant biopsies were performed in 63 patients (two had two biopsies, and one had three biopsies). There were 32 males and 31 females with an average age of 50 (range, 15-84 years). Of the 67 biopsies, five were non-diagnostic and inaccurate and thus unsuccessful (7 %); five were diagnostic but inaccurate and thus unsuccessful (7 %); 57 were diagnostic and accurate thus successful (85 %). These results were comparable with results published in the radiology literature. The success rate of CT-guided biopsies using a low-dose protocol is comparable to published rates for conventional dose biopsies. The implemented low-dose protocol

  18. Fine-needle versus core-needle biopsy – which one to choose in preoperative assessment of focal lesions in the breasts? Literature review

    Directory of Open Access Journals (Sweden)

    Ewa Łukasiewicz

    2017-12-01

    Full Text Available Aim: The aim of the study was to review two techniques that can be used to verify focal lesions in the breasts: fine-needle aspiration biopsy and core-needle biopsy. Material and methods: Fifty-five articles (original papers and reviews, half of them published within the past 5 years, were included in the analysis. The authors also took their own experience into account. Results: Pre-operative assessment of focal lesions in the breasts is crucial in the planning of further therapeutic management. The role of fine-needle aspiration biopsy has been reduced lately due to its low sensitivity and specificity as well as a high rate of non-diagnostic, suspicious and false negative results. This method does not enable one to differentiate between in situ and invasive disease. Currently, fine-needle biopsy is recommended for cystic lesions, suspected of being recurrences in the chest wall, and lymph node metastases. Core-needle biopsy is the basic diagnostic method of breast lesions. According to the recommendations of the Polish Ultrasound Society and American College of Radiology, BIRADS 4 and 5 lesions should be evaluated histopathologically. Core-needle biopsy makes it possible to establish a final diagnosis more frequently than fine-needle biopsy, both in the case of benign and malignant lesions. It delivers more information about the nature of a tumor (mutation of HER-2, estrogen and progesterone receptors and Ki-67 index. Its limitations include: underestimation of invasion and failure to recognize the components of ductal carcinoma in situ in papillary and atypical lesions. Single fine-needle aspiration biopsy is inexpensive, but when considering the cost of further diagnosis due to non-diagnostic, suspicious and atypical results, this method generates high additional costs. Conclusions: Microscopic verification of focal breast lesions is crucial for further therapeutic decisions. It has been proven that histopathological verification is more

  19. Role of endoscopic ultrasound-guided fine-needle aspiration in adrenal lesions: analysis of 32 patients

    Directory of Open Access Journals (Sweden)

    Rakesh K Gupta

    2018-01-01

    Full Text Available Objective: Endoscopic ultrasound-guided fine-needle aspiration cytology (EUS-FNAC is a precise and safe technique that provides both radiological and pathological diagnosis with a better diagnostic yield and minimal adverse events. EUS-FNAC led to the remarkable increase in the detection rate of incidentaloma found during radiologic staging or follow-up in various malignancy or unrelated conditions. Aims: We did this preliminary study with an aim to evaluate the role of EUS-FNA in diagnosing and classifying adrenal lesions, clinical impact, and compare the outcome with the previously published literature. Materials and Methods: We included 32 consecutive cases (both retrospective and prospective of EUS-guided adrenal aspirate performed over a period of 3.3 years. The indications for the aspirate in decreasing order were metastasis (most common carcinoma gall bladder > primary adrenal mass > disseminated tuberculosis > pyrexia of unknown origin. On EUS, 28 cases revealed space occupying lesion or mass (two cases bilateral and four cases revealed diffuse enlargement (two cases bilateral with a mean size of 21 mm. Results: The cytology reports were benign adrenal aspirate (43.8%, metastatic adenocarcinoma (15.6%, histoplasmosis (9.4%, tuberculosis (9.4%, round cell tumor (6.2%, adrenocortical carcinoma (3.1%, and descriptive (3.1%. Three cases (9.4% yielded inadequate sample. The TNM staging was altered in 22.23% of the cases by result of adrenal aspirate. Conclusions: EUS-FNA of the adrenal gland is a safe, quick, and sensitive and real-time diagnostic technique, which requires an integrated approach of clinician, endoscopist, and cytopathologist for high precision in diagnosis. Although the role of EUS-FNA for right adrenal is not much described, we found adequate sample yield in all the four patients that underwent the procedure.

  20. Feasibility Study of Needle Placement in Percutaneous Vertebroplasty: Cone-Beam Computed Tomography Guidance Versus Conventional Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Braak, Sicco J., E-mail: sjbraak@gmail.com [St. Antonius Hospital, Department of Radiology (Netherlands); Zuurmond, Kirsten, E-mail: kirsten.zuurmond@philips.com; Aerts, Hans C. J., E-mail: hans.cj.aerts@philips.com [Philips Medical, Department of Clinical Development (Netherlands); Leersum, Marc van, E-mail: m.van.leersum@antoniusziekenhuis.nl; Overtoom, Timotheus T. Th., E-mail: overtm@knoware.nl; Heesewijk, Johannes P. M. van, E-mail: j.heesewijk@antoniusziekenhuis.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl [St. Antonius Hospital, Department of Radiology (Netherlands)

    2013-08-01

    ObjectiveTo investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.Materials and MethodsOn 4 spine phantoms with 11 vertebrae (Th7-L5), 4 interventional radiologists (2 experienced with CBCT guidance and two inexperienced) punctured all vertebrae in a bipedicular fashion. Each side was randomization to either CBCT guidance or fluoroscopy. CBCT guidance is a sophisticated needle guidance technique using CBCT, navigation software, and real-time fluoroscopy. The placement of the needle had to be to a specific target point. After the procedure, CBCT was performed to determine the accuracy, procedure time, fluoroscopy time, and DAP. Analysis of the difference between methods and experience level was performed.ResultsMean accuracy using CBCT guidance (2.61 mm) was significantly better compared with fluoroscopy (5.86 mm) (p < 0.0001). Procedure time was in favor of fluoroscopy (7.39 vs. 10.13 min; p = 0.001). Fluoroscopy time during CBCT guidance was lower, but this difference is not significant (71.3 vs. 95.8 s; p = 0.056). DAP values for CBCT guidance and fluoroscopy were 514 and 174 mGy cm{sup 2}, respectively (p < 0.0001). There was a significant difference in favor of experienced CBCT guidance users regarding accuracy for both methods, procedure time of CBCT guidance, and added DAP values for fluoroscopy.ConclusionCBCT guidance allows users to perform PVP more accurately at the cost of higher patient dose and longer procedure time. Because procedural complications (e.g., cement leakage) are related to the accuracy of the needle placement, improvements in accuracy are clinically relevant. Training in CBCT guidance is essential to achieve greater accuracy and decrease procedure time/dose values.

  1. Isolated and unexplained dilation of the common bile duct on computed tomography scanscans

    Directory of Open Access Journals (Sweden)

    Naveen B. Krishna

    2012-07-01

    Full Text Available Isolated dilation of common bile duct (CBD with normal sized pancreatic duct and without identifiable stones or mass lesion (unexplained is frequently encountered by computed tomography/magnetic resonance imaging. We studied the final diagnoses in these patients and tried to elucidate factors that can predict a malignant etiology. This is a retrospective analysis of prospective database from a University based clinical practice (2002- 2008. We included 107 consecutive patients who underwent endoscopic ultrasound (EUS for evaluation of isolated and unexplained CBD dilation noted on contrast computed tomography scans. EUS examination was performed using a radial echoendoscope followed by a linear echoechoendoscope, if a focal mass lesion was identified. Fine-needle aspirates were assessed immediately by an attending cytopathologist. Main outcome measurements included i prevalence of neoplasms, CBD stones and chronic pancreatitis and ii performance characteristics of EUS/EUS-fine needle aspiration (EUS-FNA. A malignant neoplasm was found in 16 patients (14.9% of the study subjects, all with obstructive jaundice (ObJ. Six patients had CBD stones; three with ObJ and three with abnormal liver function tests. EUS findings suggestive of chronic pancreatitis were identified in 27 patients. EUSFNA had 97.3% accuracy (94.1% in subset with ObJ with a sensitivity of 81.2% and specificity of 100% for diagnosing malignancy. Presence of ObJ and older patient age were only significant predictors of malignancy in our cohort. Amongst patients with isolated and unexplained dilation of CBD, the risk of malignancy is significantly higher in older patients presenting with ObJ. EUS-FNA can diagnose malignancy in these patients with high accuracy besides identifying other potential etiologies including missed CBD stones and chronic pancreatitis.

  2. Smartphone-Guided Needle Angle Selection During CT-Guided Procedures.

    Science.gov (United States)

    Xu, Sheng; Krishnasamy, Venkatesh; Levy, Elliot; Li, Ming; Tse, Zion Tsz Ho; Wood, Bradford John

    2018-01-01

    In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm). Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.

  3. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    Science.gov (United States)

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  4. Fine needle aspiration cytology of breast lumps with histopathologic ...

    African Journals Online (AJOL)

    diagnosis of palpable breast lesions, in recent years two types of minimally invasive .... negative predictive value of FNAC as a diagnostic pro- cedure for the entire ... The earliest large scale use of Fine Needle aspiration. Cytology FNAC as a ...

  5. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    Science.gov (United States)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  6. Computed tomography in the evaluation of soft tissue tumors. Report in 124 cases

    Energy Technology Data Exchange (ETDEWEB)

    Torricelli, P; Calo, M; Boriani, S; De Santis, G

    1986-01-01

    In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies. 39 refs.

  7. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  8. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  9. First-in-Man Computed Tomography-Guided Percutaneous Revascularization of Coronary Chronic Total Occlusion Using a Wearable Computer: Proof of Concept.

    Science.gov (United States)

    Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Szpak, Marcin; Staruch, Adam D; Kepka, Cezary; Witkowski, Adam

    2016-06-01

    We report a case of successful computed tomography-guided percutaneous revascularization of a chronically occluded right coronary artery using a wearable, hands-free computer with a head-mounted display worn by interventional cardiologists in the catheterization laboratory. The projection of 3-dimensional computed tomographic reconstructions onto the screen of virtual reality glass allowed the operators to clearly visualize the distal coronary vessel, and verify the direction of the guide wire advancement relative to the course of the occluded vessel segment. This case provides proof of concept that wearable computers can improve operator comfort and procedure efficiency in interventional cardiology. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  10. The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours

    International Nuclear Information System (INIS)

    Solivetti, Francesco Maria; Elia, Fulvia; Santaguida, Maria Giulia; Guerrisi, Antonino; Visca, Paolo; Cercato, Maria Cecilia; Di Carlo, Aldo

    2014-01-01

    The primary aim of this study was to evaluate the diagnostic accuracy of ultrasound (US) in the study of superficial lymph nodes during the follow-up of patients surgically treated for skin tumours. The secondary objective was to compare positive cytological results with histological reports. From 2004 to 2011, 480 patients (male/female: 285/195; median age 57 years; prevalent skin tumour: melanoma) underwent US-guided fine-needle aspiration biopsy (FNAB) of suspicious recurrent lymph nodes. An expert radiologist first performed US testing of the lymph nodes, expressing either a negative or positive outcome of the test. Subsequently, US-guided FNAB was performed. FNAB positive patients were subjected to lymphadenectomy; the patients who tested negative underwent the follow-up. The size of lymph nodes was ≤ 2 cm in 90% of cases. Out of the 336 (70%) US “positive” patients, 231 (68.8%) were FNAB positives. Out of the 144 (30%) US “negatives”, 132 (91.7%) were FNAB negatives. The sensitivity and specificity of the US were 95% and 55.7%, respectively; the negative predictive value was 91.7% and the positive predictive value was 68.8%. Definitive histological results confirmed FNAB positivity in 97.5% of lymphadenectomies. US is a sensitive method in the evaluation of superficial lymph nodes during the follow-up of patients with skin tumours. High positive predictive value of cytology was confirmed

  11. The value of preoperative ultrasound guided fine-needle aspiration cytology of radiologically suspicious axillary lymph nodes in breast cancer

    Directory of Open Access Journals (Sweden)

    Torill Sauer

    2014-01-01

    Full Text Available Background: Preoperative ultrasound (US and eventually US-guided fine-needle aspiration cytology (FNAC of suspicious axillary lymph nodes (ALN is a standard procedure in the work-up of suspicious breast lesions. Preoperative US FNAC may prevent sentinel node biopsy (SNB procedure in 24-30% of patients with early stage breast carcinoma. The aim of this study was to evaluate the institutional results of this preoperative diagnostic procedure. Materials and Methods: A total of 182 cases of preoperative FNAC of suspicious ALN where retrieved from the pathology files. The results were compared with the final histology and staging. False negative (FN FNAC cases were reviewed and possibly missed metastatic cases (2 were immunostained with the epithelial marker AE1/AE3. Results: There were no false positives, whereas 16 cases were FN. In all but one case the FN′s represented sampling error. Half of the 16 FN cases in this series were macrometastases. Discussion: About 83% of the preoperatively aspirated cases were N+, indicating that a radiologically suspicious ALN has a very high risk of being metastatic. Preoperative US guided FNAC from radiologically suspicious ALN is highly efficient in detecting metastases. Depending on national guidelines, a preoperative, positive ALN FNAC might help to stratify the patients as to SNB and/or ALN dissection.

  12. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    Science.gov (United States)

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (ptechnical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  14. Diagnostic accuracy of fine needle aspiration cytology in patients ...

    African Journals Online (AJOL)

    Objective: To estimate the sensitivity and specificity of FNAC in detecting malignancy for thyroid disease using histopathology ... thyroid carcinoma being the most predominant type and colloid goiter was the most predominant benign thyroid disease. The sensitivity ..... tic accuracy of fine needle aspiration cytology in thyroid.

  15. Thyroid fine-needle aspiration and the bethesda classification system

    DEFF Research Database (Denmark)

    Larsen, Louise Vølund; Egset, Alice Viktoria; Holm, Camilla

    2018-01-01

    INTRODUCTION: Fine-needle aspiration (FNA) is a cornerstone in diagnosing thyroid nodules. For decades, Danish FNA have been categorised into the groups: “FNA not per-formed”, “Inadequate”, “Cystic”, “Inconclusive”, “Benign”, “Suspicious”, “Malignant” and “Information missing”. Internationally...

  16. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    Science.gov (United States)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  17. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  18. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  19. Role of fine needle aspiration cytology in the preoperative investigation of branchial cysts.

    Science.gov (United States)

    Slater, Jacqueline; Serpell, Jonathan W; Woodruff, Stacey; Grodski, Simon

    2012-01-01

    Successful preoperative diagnosis of a branchial cyst requires a systematic approach. The aim of this study was to evaluate methods of investigation of a lateral neck swelling suspicious for a branchial cyst, and to highlight cases where a less benign cause for the swelling should be suspected and therefore management altered appropriately. A retrospective case study of 24 patients with presumed branchial cysts managed operatively was undertaken. Demographic, clinical, imaging, cytology and histopathological data were analysed to formulate an approach to the work-up of a lateral neck swelling suspected to be a branchial cyst. All 24 patients presented with a lateral neck mass thought to be a branchial cyst preoperatively underwent preoperative fine-needle aspiration cytology. The overall accuracy of cytology in predicting a benign branchial cyst histopathologically was 83.3% (20 out of 24). Successful preoperative diagnosis of a branchial cyst requires a combination of imaging and cytology. If there is concern that a lateral neck swelling is not a branchial cyst on clinical, imaging or cytological features, then a full preoperative work-up, including computed tomography scan of the neck and upper aero-digestive tract endoscopy should be performed, prior to an excisional biopsy. © 2011 The Authors. ANZ Journal of Surgery © 2011 Royal Australasian College of Surgeons.

  20. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  1. Cone-Beam Computed Tomography-Guided Percutaneous Radiologic Gastrostomy

    International Nuclear Information System (INIS)

    Moehlenbruch, Markus; Nelles, Michael; Thomas, Daniel; Willinek, Winfried; Gerstner, Andreas; Schild, Hans H.; Wilhelm, Kai

    2010-01-01

    The purpose of this study was to investigate the feasibility of a flat-detector C-arm-guided radiographic technique (cone-beam computed tomography [CBCT]) for percutaneous radiologic gastrostomy (PRG) insertion. Eighteen patients (13 men and 5 women; mean age 62 years) in whom percutaneous endoscopic gastrostomy (PEG) had failed underwent CBCT-guided PRG insertion. PEG failure or unsuitability was caused by upper gastrointestinal tract obstruction in all cases. Indications for gastrostomy were esophageal and head and neck malignancies, respectively. Before the PRG procedure, initial C-arm CBCT scans were acquired. Three- and 2-dimensional soft-tissue reconstructions of the epigastrium region were generated on a dedicated workstation. Subsequently, gastropexy was performed with T-fasteners after CBCT-guided puncture of the stomach bubble, followed by insertion of an 14F balloon-retained catheter through a peel-away introducer. Puncture of the stomach bubble and PRG insertion was technically successful in all patients without alteration of the epigastric region. There was no malpositioning of the tube or other major periprocedural complications. In 2 patients, minor complications occurred during the first 30 days of follow-up (PRG malfunction: n = 1; slight infection: n = 1). Late complications, which were mainly tube disturbances, were observed in 2 patients. The mean follow-up time was 212 days. CBCT-guided PRG is a safe, well-tolerated, and successful method of gastrostomy insertion in patients in whom endoscopic gastrostomy is not feasible. CBCT provides detailed imaging of the soft tissue and surrounding structures of the epigastric region in one diagnostic tour and thus significantly improves the planning of PRG procedures.

  2. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    Science.gov (United States)

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  3. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    Science.gov (United States)

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  4. Diffuse optical tomography for breast cancer imaging guided by computed tomography: A feasibility study.

    Science.gov (United States)

    Baikejiang, Reheman; Zhang, Wei; Li, Changqing

    2017-01-01

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as hemoglobin, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer imaging. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at the wavelength of 650 nm and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements and width of measurement patch, have been investigated. Our results indicate that an air-cooling EMCCD camera is good enough for the transmission mode DOT imaging. We have also found that measurements at six angular projections are sufficient for DOT to reconstruct the optical targets with 2 and 4 times absorption contrast when the CT guidance is applied. Finally, we have described our future research plan on integration of a multispectral DOT imaging system into a breast CT scanner.

  5. Is percutaneous fine-needle biopsy a hazard? An update

    International Nuclear Information System (INIS)

    Smith, E.H.

    1987-01-01

    Fine-needle biopsy (FNB) has become a commonplace diagnostic procedure in most radiology departments with the assumption that risks are nonexistent. Animal experiments conclusively indicate the leakage of tumor cells after biopsy, but clinical evidence appears to point to a paucity of complications. In a prior review of the literature, two needle tract seedings (NTS) and two fatalities after FNB were discovered. A questionnaire at that time uncovered three more cases of NTS and four deaths. An updated literature search and questionnaire showed an additional 14 cases of NTS and nine deaths. An analysis of the date are reported

  6. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    Science.gov (United States)

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  7. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological...... diagnostic classes were introduced. The aim of this study was to evaluate the quality assurance programme in a screening population to determine whether fine needle aspiration cytology (FNAC) as first choice remains a useful tool in the preoperative diagnostics, or if needle core biopsy should be the first...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  8. Primary splenic angiosarcoma with liver metastasis: A rare neoplasm diagnosed on fine-needle aspiration cytology and cell block immunocytochemistry

    Directory of Open Access Journals (Sweden)

    Saniya Sharma

    2018-01-01

    Full Text Available Primary splenic angiosarcoma is a rare malignant vascular neoplasm of mesenchymal origin. The tumor is highly aggressive and has a high metastatic potential. It is usually diagnosed on histopathological examination of splenectomy specimen. Only few cases of angiosarcoma diagnosed by fine-needle aspiration (FNA cytology alone have been reported in the literature. The cytologic features of angiosarcoma are heterogeneous, however, diagnosis can be suggested by FNA when vasoformative features are present. A 55-year-old female presented with abdominal pain and hepatosplenomegaly. Computed tomography scan revealed a heterogeneous splenic lesion with liver metastases. FNA from the splenic and liver lesions showed moderately pleomorphic tumor cells closely associated with anastomosing vascular channels. Cell block immunocytochemistry (ICC showed tumor cells positive for CD31, CD34, CD68 as well as for CD99. FNA supplemented by cell block ICC can render a definite diagnosis of primary splenic angiosarcoma with liver metastasis.

  9. Sonographic features and ultrasonography-guided fine-needle aspiration of metastases to the thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Hyun; Kim, Eun Kyung; Kwak, Jin Young; Moon, Hee Jung; Kim, Ga Ram [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-03-15

    To evaluate the characteristic ultrasonographic (US) features of metastatic carcinoma to the thyroid, and how accurate US features and ultrasonography-guided fine-needle aspiration (US-FNA) are for the diagnosis of thyroid metastases. Twenty-three thyroid lesions in 23 patients (mean age, 66.7 years; range, 46 to 85 years) that had been diagnosed as thyroid metastases were included. The composition, echogenicity, margin, shape, presence of calcifications, underlying parenchymal echotexture, and vascularity were analyzed in US images of the thyroid metastases. Final US assessments were categorized into probably benign and suspicious malignancy. The presence of suspicious metastatic cervical lymph nodes was noted. The medical records, US-FNA cytology, and pathology reports of these patients were retrospectively reviewed. Of the 23 thyroid lesions, the general US appearance was mass-forming in 21 (91.3%) and non-mass-forming in 2 (8.7%). All 23 lesions showed a solid tumor composition. Common US features among the 21 mass-forming thyroid metastases were hypoechogenicity (81.0%), non-circumscribed margins (90.5%), no calcifications (76.2%), and parallel shape (81.0%). Suspicious cervical lymph nodes were present in 18 patients (78.3%). Of the 23 lesions, 21 (91.3%) were classified as suspicious malignancy, and 2 (8.7%) as probably benign. US-FNA showed diagnostic results specific for metastases in 21 of the 22 patients (95.5%) who had undergone US-FNA. Common US features in thyroid metastasis were hypoechogenicity, non-circumscribed margins, no calcifications, parallel shape, and the presence of suspicious cervical lymph nodes. US-FNA can be effectively used in the diagnosis of thyroid metastasis, preventing unnecessary surgery.

  10. C-arm Cone Beam Computed Tomographic Needle Path Overlay for Fluoroscopic-Guided Placement of Translumbar Central Venous Catheters

    International Nuclear Information System (INIS)

    Tam, Alda; Mohamed, Ashraf; Pfister, Marcus; Rohm, Esther; Wallace, Michael J.

    2009-01-01

    C-arm cone beam computed tomography is an advanced 3D imaging technology that is currently available on state-of-the-art flat-panel-based angiography systems. The overlay of cross-sectional imaging information can now be integrated with real-time fluoroscopy. This overlay technology was used to guide the placement of three percutaneous translumbar inferior vena cava catheters.

  11. Image-guided biopsy in patients with suspected ovarian carcinoma: a safe and effective technique?

    International Nuclear Information System (INIS)

    Griffin, Nyree; Grant, Lee A.; Freeman, Susan J.; Berman, Laurence H.; Sala, Evis; Jimenez-Linan, Mercedes; Earl, Helena; Ahmed, Ahmed Ashour; Crawford, Robin; Brenton, James

    2009-01-01

    In patients with suspected advanced ovarian carcinoma, a precise histological diagnosis is required before commencing neo-adjuvant chemotherapy. This study aims to determine the diagnostic accuracy and complication rate of percutaneous biopsies performed under ultrasound or computed tomography guidance. Between 2002 to 2007, 60 consecutive image-guided percutaneous biopsies were performed in patients with suspected ovarian cancer. The following variables were recorded: tissue biopsied, imaging technique, experience of operator, biopsy needle gauge, number of passes, complications, and final histology. Forty-seven patients had omental biopsies, 12 pelvic mass biopsies, and 1 para-aortic lymph node biopsy. Thirty-five biopsies were performed under ultrasound, 25 under computed tomography guidance. Biopsy needle gauges ranged from 14-20 swg with two to five passes for each patient. There were no complications. Histology was obtained in 52 (87%) patients. Percutaneous image-guided biopsy of peritoneal disease or pelvic mass is safe with high diagnostic accuracy. The large-gauge biopsy needle is as safe as the small gauge needle, but has the added value of obtaining tissue samples for immunohistochemistry and genomic studies. (orig.)

  12. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heerink, W.J.; Vliegenthart, R. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Bock, G.H. de [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Epidemiology, University of Groningen, Groningen (Netherlands); Jonge, G.J. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Groen, H.J.M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Pulmonary Medicine, University of Groningen, Groningen (Netherlands); Oudkerk, M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands)

    2017-01-15

    To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. (orig.)

  13. Relationship of pancreatic mass size and diagnostic yield of endoscopic ultrasound-guided fine needle aspiration.

    Science.gov (United States)

    Siddiqui, Ali A; Brown, Lauren J; Hong, Shih-Kuang S; Draganova-Tacheva, Rossitza A; Korenblit, Jason; Loren, David E; Kowalski, Thomas E; Solomides, Charalambos

    2011-11-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is central to discerning the diagnosis of solid pancreatic tumors through tissue acquisition. Test performance is affected by a number of factors including location of mass within the pancreas, presence of onsite cytology technologist, and number of passes with the needle. The influence of tumor size has not been well studied. The objective of the current study was to determine whether the size of mass affects the diagnostic accuracy for solid pancreatic lesions aspirated under EUS guidance. Data were collected retrospectively on all patients with solid pancreatic masses undergoing EUS-FNA from June 2003 to August 2010. The cytology samples were reported as positive, suspicious for malignancy, atypical, negative, or nondiagnostic. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. Patients were divided into five groups based upon lesion size as follows: (a) less than 1 cm, (b) 1-2 cm, (c) 2-3 cm, (d) 3-4 cm, and (e) greater than 4 cm. Performance characteristics of EUS-FNA including sensitivity, specificity, and accuracy were compared for each group. Accuracy was defined as the ratio of the sum of true-positive and true-negative values divided by the number of lesions. We identified 583 patients with solid pancreatic lesions in which EUS-FNA was performed and adequate cellularity was obtained (47% men, mean age 65 ± 1.4 (SE) years). Overall, 486 (83%) of lesions were pancreatic adenocarcinoma, 18 (3%) were neuroendocrine tumors, 12 (2%) were lymphomas, and 67 (12%) were benign lesions. The median size of the mass was 3 cm (range, 0.5-7 cm). A mean of 4.9 passes (range, 1-9 passes) was needed to obtain adequate samples from lesions. The overall yield of obtaining adequate samples for diagnosis was 85%. When stratified by size, the EUS-FNA sensitivity for lesions with size 4 cm was 40, 75.9, 86.9, 93

  14. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    Science.gov (United States)

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  15. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    Jun 15, 2011 ... guided PFNAB/US-guided PNCB was the diagnostic test in 23.33% cases. It confirmed a highly ..... provides guidance in multiple axial, longitudinal and .... Source of Support: Nil, Con.ict of Interest: None declared. Gani, et al.

  16. Feasibility of Computed Tomography-Guided Methods for Spatial Normalization of Dopamine Transporter Positron Emission Tomography Image.

    Science.gov (United States)

    Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik

    2015-01-01

    Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD). We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.

  17. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  18. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  19. Anterior versus lateral needle decompression of tension pneumothorax: comparison by computed tomography chest wall measurement.

    Science.gov (United States)

    Sanchez, Leon D; Straszewski, Shannon; Saghir, Amina; Khan, Atif; Horn, Erin; Fischer, Christopher; Khosa, Faisal; Camacho, Marc A

    2011-10-01

    Recent research describes failed needle decompression in the anterior position. It has been hypothesized that a lateral approach may be more successful. The aim of this study was to identify the optimal site for needle decompression. A retrospective study was conducted of emergency department (ED) patients who underwent computed tomography (CT) of the chest as part of their evaluation for blunt trauma. A convenience sample of 159 patients was formed by reviewing consecutive scans of eligible patients. Six measurements from the skin surface to the pleural surface were made for each patient: anterior second intercostal space, lateral fourth intercostal space, and lateral fifth intercostal space on the left and right sides. The distance from skin to pleura at the anterior second intercostal space averaged 46.3 mm on the right and 45.2 mm on the left. The distance at the midaxillary line in the fourth intercostal space was 63.7 mm on the right and 62.1 mm on the left. In the fifth intercostal space the distance was 53.8 mm on the right and 52.9 mm on the left. The distance of the anterior approach was statistically less when compared to both intercostal spaces (p < 0.01). With commonly available angiocatheters, the lateral approach is less likely to be successful than the anterior approach. The anterior approach may fail in many patients as well. Longer angiocatheters may increase the chances of decompression, but would also carry a higher risk of damage to surrounding vital structures. © 2011 by the Society for Academic Emergency Medicine.

  20. Clinical analysis of 44 lung abscess cases

    International Nuclear Information System (INIS)

    Uruga, Hironori; Hanada, Shigeo; Takaya, Hisashi; Miyamoto, Atsushi; Morokawa, Nasa; Kishi, Kazuma

    2012-01-01

    Lung abscess is frequently caused by anaerobes that are difficult to diagnose by sputum examination. To evaluate diagnostic methods and bacteriology of lung abscesses, we retrospectively studied 44 consecutive lung abscess cases (37 men; 7 women; median age, 60 years) admitted and treated at our hospital from 2001 to 2010. The most frequent underlying disease was periodontitis (n=20, 45.5%). The diagnostic rate of causative pathogens by ultrasonography-guided fine-needle aspiration (n=2), computed tomography (CT)-guided fine-needle aspiration (n=19), sputum examination (n=37), and bronchoscopy (n=10) was 100, 68.4, 16.2, and 10%, respectively. In total, 43 causative pathogens were identified in 18 cases (40.9%), of which 12 (67%) had polymicrobial infections. Furthermore, anaerobes and bacterial species belonging to the Streptococcus anginosus group accounted for 55.8 and 14% of the 43 identified pathogens, and both were identified by examination of CT-guided fine-needle aspiration fluid in all cases, except for one patient. Every case was successfully treated with antibiotics. Anaerobes and species of the S. anginosus group are common causes of lung abscess, and CT-guided fine-needle aspiration is a useful diagnostic tool for identifying these causative agents. (author)

  1. Cranial radiotherapy guided by computed tomography with or without fields conformation in pediatric

    International Nuclear Information System (INIS)

    Fernandez, Diego; Caussa, Lucas; Murina, Patricia; Zunino, Silvia

    2007-01-01

    Many malignancies in children can be cured by radiotherapy, acute toxicity and the significant effect of delayed treatment are worrying for the patient, family and society. Therefore, the end of the pediatric radiotherapy is to maintain or improve the cure rate of cancer, diminishing the aftermath of treatment. The goal of this study is to measure differences in doses to the healthy tissue of the central nervous system with two radiotherapy techniques, both guided by computed tomography [es

  2. Assessment of pain score and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy of thyroid nodules

    Directory of Open Access Journals (Sweden)

    Liao LJ

    2017-12-01

    Full Text Available Li-Jen Liao,1 Wu-Chia Lo,1 Wan-Lun Hsu,2 Po-Wen Cheng,1 Cheng-Ping Wang3 1Department of Otolaryngology, Far Eastern Memorial Hospital, 2Genomics Research Center, Academia Sinica, 3Department of Otolaryngology, National Taiwan University Hospital, Taipei, Taiwan, Republic of China Objective: The aim of this study was to evaluate pain scores and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy (US-FNAB of thyroid nodules without and with local anesthesia (LA. Materials and methods: The US-FNAB procedure was performed on 183 patients with and without LA. One puncture was made for solid nodules, and if patients could tolerate it, a two-puncture technique was used for nodules with a cystic change. Four-point verbal rating scores were assessed by a nursing assistant after completion of US-FNAB. To be an adequate specimen, at least six groups of follicular cells are required, and each group should contain at least 10 cells.Results: Immediately after US-FNAB, 92% of patients with LA and 80% without LA reported no or mild pain (p=0.01. Most patients tolerated the procedure well, with no pain (82.5% reported 5 minutes after the procedure. In univariate logistic regression, irregular boundary (odds ratio [OR]: 2.52, 95% confidence interval [CI]: 1.04–6.06, p=0.04, calcification (OR: 2.86, 95% CI: 1.06–7.76, p=0.04, and LA (OR: 0.35, 95% CI: 0.15–0.86, p=0.02 were significantly associated with immediate moderate or severe pain. Specimen adequacy was significantly associated with age (OR: 0.95, 95% CI: 0.92–0.97, p<0.01, heterogeneous echo-texture (OR: 1.76, 95% CI: 1.23–5.17, p=0.01, predominate solid architecture (OR: 2.78, 95% CI: 1.42–5.41, p<0.01, and the use of LA (OR: 3.34, 95% CI: 1.70–6.56, p<0.01. In multivariate logistic regression, patients receiving LA had lower risk of moderate or severe pain (OR: 0.25, 95% CI: 0.09–0.67, p=0.01 and higher chances of specimen adequacy (OR: 4.84, 95% CI: 2.17–10.7, p<0

  3. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    DEFF Research Database (Denmark)

    Konge, Lars; Vilmann, P; Clementsen, P

    2012-01-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliabilit...... and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC....

  4. Computed tomography of the breast: a valuable adjunct to mammography in selected cases

    International Nuclear Information System (INIS)

    Van Gelderen, W.F.C.; Tygerberg Hospital, Cape Town

    1995-01-01

    Computed tomography (CT) is not often used for the further assessment of a mass in the breast. In the case presented it proved to be invaluable in demonstrating a very posterior breast mass previously sub optimally demonstrated a mammography, not palpable clinically, and not visualized on ultrasound examination. The predicament of a very posterior breast mass is highlighted and it is suggested that present-day routine cranio-caudal and oblique views may not be adequate to show such a mass even if meticulous attention to radiograph technique is given. If the supine-oblique view with balloon compression cannot be obtained, CT in the prone position with the breasts dependent may be the best alternative. Fine needle aspiration biopsy can be performed under CT guidance in such cases. 4 refs., 3 figs

  5. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  6. Predictors of Malignancy and Recommended Follow-Up for Patients with Negative Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Suspected Pancreatic Lesions

    Directory of Open Access Journals (Sweden)

    Bret J Spier

    2009-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA can characterize and diagnose pancreatic lesions as malignant, but cannot definitively rule out the presence of malignancy. Outcome data regarding the length of follow-up in patients with negative or nondiagnostic EUS-FNA of pancreatic lesions are not well-established.

  7. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  8. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  9. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms.

    Science.gov (United States)

    Ben-Shlomo, A; Cohen, D; Bruckheimer, E; Bachar, G N; Konstantinovsky, R; Birk, E; Atar, E

    2016-05-01

    To compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT. Effective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms. The effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590% for upper lung, 639 and 525% for mid-lung, and 461 and 251% for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762% for liver and 513 and 608% for kidney biopsies. Based on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  10. a pilot study of the diagnostic accuracy of fine needle aspirate cytol

    African Journals Online (AJOL)

    2018-06-02

    Jun 2, 2018 ... Fibroadenoma of the breast in a South African population -a pilot study of the ... Keywords: Fibroadenoma, diagnosis, breast ultrasonography, fine needle ..... breast cancer among Sudanese patients with breast palpa-.

  11. The using of megavoltage computed tomography in image-guided brachytherapy for cervical cancer: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Tharavichitkul, Ekkasit; Janla-or, Suwapim; Wanwilairat, Somsak; Chakrabandhu, Somvilai; Klunklin, Pitchayaponne; Onchan, Wimrak; Supawongwattana, Bongkot; Chitapanarux, Imjai [Division of Therapeutic Radiology and Oncology, Dept. of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai (Thailand); Galalae, Razvan M. [Faculty of Medicine, Christian-Albrecht University (Campus Kiel), Kiel (Germany)

    2015-06-15

    We present a case of cervical cancer treated by concurrent chemoradiation. In radiation therapy part, the combination of the whole pelvic helical tomotherapy plus image-guided brachytherapy with megavoltage computed tomography of helical tomotherapy was performed. We propose this therapeutic approach could be considered in a curative setting in some problematic situation as our institution.

  12. Fine-needle cytology of breast lesions seen on mammograms

    International Nuclear Information System (INIS)

    Schmidt, R.A.; Ridlen, M.S.; Dowlatshahi, K.; Jokich, P.M.; Bibbo, M.

    1989-01-01

    Stereotactic fine-needle aspiration of nonpalpable breast lesions is operator dependent. The authors have analyzed 250 biopsies at our institution (comparing aspiration cytology with surgical biopsy) for sensitivity, false-negative, and insufficient-sample rates of three different interpreters. Needle aspiration as an alternative to biopsy or a follow-up for lesions of low mammographic suspicion would have resulted in detection of most, but not all, cancers. Over 40 additional biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies for low-suspicion lesions could be avoided. Aspiration cytologic series should report separately insufficient samples and LCIS, and should use a consistent threshold for interpreting cytologic results

  13. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    Science.gov (United States)

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (pcore (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  14. Fine focal spot size improves image quality in computed tomography abdomen and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Goh, Yin P.; Low, Keat; Kuganesan, Ahilan [Monash Health, Diagnostic Imaging Department, 246, Clayton Road, Clayton, Victoria (Australia); Lau, Kenneth K. [Monash Health, Diagnostic Imaging Department, 246, Clayton Road, Clayton, Victoria (Australia); Monash University, Department of Medicine, Faculty of Medicine, Nursing and Health Sciences, Victoria (Australia); Buchan, Kevin [Philips Healthcare, Clinical Science, PO Box 312, Mont Albert, Victoria (Australia); Oh, Lawrence Chia Wei [Flinders Medical Centre, Division of Medical Imaging, Bedford Park South (Australia); Huynh, Minh [Swinburne University, Department of Statistics, Data Science and Epidemiology, School of Health Sciences, Faculty of Health, Arts and Design, Hawthorn (Australia)

    2016-12-15

    To compare the image quality between fine focal spot size (FFSS) and standard focal spot size (SFSS) in computed tomography of the abdomen and pelvis (CTAP) This retrospective review included all consecutive adult patients undergoing contrast-enhanced CTAP between June and September 2014. Two blinded radiologists assessed the margin clarity of the abdominal viscera and the detected lesions using a five-point grading scale. Cohen's kappa test was used to examine the inter-observer reliability between the two reviewers for organ margin clarity. Mann-Whitney U testing was utilised to assess the statistical difference of the organ and lesion margin clarity. 100 consecutive CTAPs were recruited. 52 CTAPs were examined with SFSS of 1.1 x 1.2 mm and 48 CTAPs were examined with FFSS of 0.6 x 0.7 mm. Results showed that there was substantial agreement for organ margin clarity (mean κ = 0.759, p < 0.001) among the reviewers. FFSS produces images with clearer organ margins (U = 76194.0, p < 0.001, r = 0.523) and clearer lesion margins (U = 239, p = 0.052, r = 0.269). FFSS CTAP improves image quality in terms of better organ and lesion margin clarity. Fine focus CT scanning is a novel technique that may be applied in routine CTAP imaging. (orig.)

  15. Comparison of specimen adequacy in fine needle aspiration cytology performed with different gauge needles in palpable external swellings

    International Nuclear Information System (INIS)

    Sarfraz, T.; Bashir, S.; Tariq, H.; Malik, T.M.

    2013-01-01

    Background: Fine Needle Aspiration Cytology (FNAC) of external swellings may yield different specimen adequacy depending on different gauge needles used for aspiration. Objective: To compare the specimen adequacy aspirated by various gauge (21 and 22) needles in external palpable swellings of lymph nodes, thyroid gland, salivary glands, breast and soft tissue. Study Design: Comparative cross sectional study. Duration: Six months (1st Jan 2012 to 30th June 2012). Setting: Histopathology/Cytology department Combined Military Hospital Peshawar (Pakistan). Methodology: This was a prospective study of 200 cases in which FNAC was performed with either 21 or 22 gauge needles (100 cases with 21 gauge and 100 with 22 gauge needles). Equal number of aspirations were done with 21 and 22 gauge needles from the swellings of thyroid gland, lymph nodes, salivary glands, breast and soft tissue. Results were analyzed for specimen adequacy by using SPSS 17. Results: A total number of 200 cases were recruited in this study, out of which 100 were aspirated with 21 gauge needles and 100 with 22 gauge needles. Specimen adequacy in swellings of thyroid, lymph nodes and salivary glands was better with 22 gauge amounting 90%, 80% and 80% respectively, as compared to yield with 21 gauge needles which was 85%, 70% and 60% respectively. On the other hand in swellings of breast and soft tissue, the specimen adequacy was better with 21 gauge needles giving 98% and 90 % adequate yield respectively as compared to 22 gauge needles which was 70% and 40 % respectively. Conclusion: Needles of smaller gauge (22 gauge) give a better yield in swellings of thyroid, lymph nodes and salivary gland while in swellings of breast and soft tissue sample adequacy is better with larger gauge needle (21 gauge). (author)

  16. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology

    Directory of Open Access Journals (Sweden)

    Neda Rad

    2016-12-01

    Full Text Available Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  17. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology.

    Science.gov (United States)

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  18. Guided access cavity preparation using cone-beam computed tomography and optical surface scans - an ex vivo study

    DEFF Research Database (Denmark)

    Buchgreitz, J; Buchgreitz, M; Mortensen, D

    2016-01-01

    AIM: To evaluate ex vivo, the accuracy of a preparation procedure planned for teeth with pulp canal obliteration (PCO) using a guide rail concept based on a cone-beam computed tomography (CBCT) scan merged with an optical surface scan. METHODOLOGY: A total of 48 teeth were mounted in acrylic bloc...

  19. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ogo, Takeshi, E-mail: ogo.takeshi.hp@mail.ncvc.go.jp [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Department of Advanced Mediccal Research for Pulmonary Hypertension, National Cerebral and Cardiovascular Centre, Osaka (Japan); Fukuda, Tetsuya [Department of Radiology, National Cerebral and Cardiovascular Centre, Osaka (Japan); Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Sanda, Yoshihiro [Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Morita, Yoshiaki [Department of Radiology, National Cerebral and Cardiovascular Centre, Osaka (Japan); Asano, Ryotaro; Konagai, Nao [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Yasuda, Satoshi [Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan)

    2017-04-15

    Highlights: • Recent advancement in CT enables distal CTEpH lesions to be visualized. • We investigated the efficacy and safety of BPA guided by CBCT or ECG-gated area detector CT. • BPA guided by CBCT or ECG-gated area detector CT is effective and safe in patients with CTEpH . • These new advanced CT techniques may be useful in pre-BPA target lesion assessment. - Abstract: Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. Methods: We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1 year after BPA. Results: Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1 year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. Conclusions: BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment.

  20. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography

    International Nuclear Information System (INIS)

    Ogo, Takeshi; Fukuda, Tetsuya; Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin; Sanda, Yoshihiro; Morita, Yoshiaki; Asano, Ryotaro; Konagai, Nao; Yasuda, Satoshi

    2017-01-01

    Highlights: • Recent advancement in CT enables distal CTEpH lesions to be visualized. • We investigated the efficacy and safety of BPA guided by CBCT or ECG-gated area detector CT. • BPA guided by CBCT or ECG-gated area detector CT is effective and safe in patients with CTEpH . • These new advanced CT techniques may be useful in pre-BPA target lesion assessment. - Abstract: Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. Methods: We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1 year after BPA. Results: Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1 year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. Conclusions: BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment.

  1. Comparison of diagnostic yield of endoscopic ultrasound-guided fine-needle aspiration cytology and cell block in solid lesions

    Directory of Open Access Journals (Sweden)

    Avinash Bhat Balekuduru

    2017-01-01

    Full Text Available Background and Aim: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA is a procedure of choice for the diagnostic evaluation of submucosal and periluminal lesions. Tissue sample can be obtained by EUS-FNA cytology (FNAC or cell block (CB. The aim of the present study is to compare diagnostic yield of EUS-FNA CB and cytology in the absence of onsite pathologist following a protocol-based EUS-FNA approach in solid lesions. Patients and Methods: Participants who underwent EUS-FNA at our center for solid submucosal or periluminal lesions (pancreas, lymph node, and liver between 2014 and 2016 were included, retrospectively. The indication for the procedure along with the clinical and other investigation details and the final etiological diagnosis were recorded on uniform structured data forms. The diagnostic yield of cytology and CB were compared using McNemar's test. The P < 0.05 was considered statistically significant. Results: EUS-FNA for solid lesion was performed in 130 lesions in 101 patients during the study period. Their mean age was 52.5 ± 12 years and 42.5% were female. Pancreatic masses were the most common lesions (37.7% followed by lymph nodes (36.9%. Submucosal lesions (17.7% and liver lesions (7.7% accounted for rest of the cases. The overall diagnostic yield for EUS-FNAC (70% and CB (74.6% was not significantly different (P = 0.3 and their combined yield was 85.3%. For the 23 patients with submucosal lesion, diagnostic yield of CB (82.6% was significantly better than cytology (47.8%, P = 0.04. Conclusions: EUS-guided CB has better yield compared to cytology in gastrointestinal submucosal lesions. The combination of CB with cytology improves the overall yield of the procedure; and hence, they should be considered complimentary rather than alternatives.

  2. Fine needle aspiration cytology versus frozen section in branchial cleft cysts.

    Science.gov (United States)

    Begbie, F; Visvanathan, V; Clark, L J

    2015-02-01

    Branchial cleft cysts occur because of a failure of involution of the second branchial cleft. However, as well-differentiated squamous cell carcinoma can mimic branchial cleft cysts, there is a lack of consensus on the appropriate management of cystic neck lumps. To report our experience of fine needle aspiration cytology and frozen section examination in the management of cystic neck lumps. Retrospective case note review of patients managed in the Southern General Hospital, Scotland, UK. The sensitivity of fine needle aspiration cytology and frozen section for detecting branchial cleft cysts was 75 per cent and 100 per cent respectively. Two patients who did not undergo intra-operative frozen section examination were either over- or under-treated, which is discussed. Adult patients subjected to surgical excision of a suspected branchial cyst should undergo intra-operative frozen section analysis regardless of clinical suspicion for malignancy. This part of management is critical to ensure patients are offered appropriate treatment.

  3. Fine-needle aspiration findings of a rare hematopoietic neoplasm presenting as obstructive jaundice.

    Science.gov (United States)

    Tracht, Jessica; Ahmed, Ali M; Rosenblum Donath, Frida

    2017-12-01

    A 51-year-old female who presented with obstructive jaundice was found to have masses in the pancreatic head and tail as well as suspicious liver and periaortic masses on imaging. Aspiration cytology of the pancreatic tail mass showed abundant large single cells with vacuolated eosinophilic cytoplasm, marked nuclear pleomorphism, large bizarre irregular nuclei, binucleation, and prominent nucleoli. Numerous cells also showed intracytoplasmic black to brown pigmentation. A cell block was obtained and extensive immunohistochemical staining was performed. S-100, HMB-45, Sox10, pancytokeratin, CK7, RCC antigen, synaptophysin, HepPar 1, inhibin, CD45, CD21, and CD123 were negative, making melanoma, epithelial malignancies, lymphoma, follicular dendritic and plasmacytoid dendritic cell neoplasms less likely. CD4 and CD56 showed partial positivity, and CD68, CD163, and CD14 were positive, supporting the diagnosis of histiocytic sarcoma. Surgical specimens and immunohistochemistry confirmed the cytologic findings. Histiocytic sarcoma is a rare aggressive malignancy of histiocytic origin with most cases presenting in adults in extranodal sites, most commonly the intestinal tract. Few cases are reported in the literature, presenting diagnostic challenges for cytopathologists when seen on fine-needle aspiration. We present the first reported case of histiocytic sarcoma presenting as a pancreatic mass, diagnosed by endoscopic ultrasound guided fine-needle aspiration (EUS-FNA). This entity is rarely described on cytology and arose in a location in which EUS-FNA is the diagnostic modality of choice. This case study highlights that cytopathologists should be aware of histiocytic sarcoma occurring in extranodal locations accessible by EUS-FNA and be familiar with the cytomorphologic appearance. © 2017 Wiley Periodicals, Inc.

  4. Quantitative analysis of fine needle aspiration biopsy samples

    International Nuclear Information System (INIS)

    Rajer, M.; Kmet, M.

    2005-01-01

    Background. The fine needle aspiration biopsy (FNAB) is one of the methods used in tumour evaluation. Since a certain number of tumour cells are needed for a complete diagnostic algorithm, we wanted to test how many cells remain in the needle and syringe after routine stains have been made and which factors influence this number. The remaining cells are used in ancillary diagnostic procedures. Materials and methods. One hundred fifty two FNAB samples of tumours of the breast, thyroid and lymph nodes were included in our study. We counted the cells which were left in the needle and the syringe after the standard smears had been made. Buerker-Tuerk's chamber was used for this purpose. Results. The number of cells depended on the organ from which the cells had been aspirated, on the type of tumour and, in the case of breast cancer, also on the level of experience of the FNAB performer. The percentage of samples with too few cells for all modern diagnostic methods (<5x105 ) is lowest in FNAB of lymph nodes (4.9%), followed by breast (16.7%) and thyroid (18%). Conclusions. We concluded that FNAB in the majority of cases grants a sufficient number of cells for the standard microscopic evaluation and also ancillary diagnostic procedures. (author)

  5. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  6. How accurate are measurements of skin-lesion depths on prebiopsy supine chest computed tomography for transthoracic needle biopsies?

    International Nuclear Information System (INIS)

    Cheung, Joo Yeon; Kim, Yookyung; Shim, Sung Shine; Lee, Jin Hwa; Chang, Jung Hyun; Ryu, Yon Ju; Lee, Rena J.

    2012-01-01

    Aim: To evaluate the accuracy of depth measurements on supine chest computed tomography (CT) for transthoracic needle biopsy (TNB). Materials and methods: We measured skin-lesion depths from the skin surface to nodules on both prebiopsy supine CT scans and CT scans obtained during cone beam CT-guided TNB in the supine (n = 29) or prone (n = 40) position in 69 patients, and analyzed the differences between the two measurements, based on patient position for the biopsy and lesion location. Results: Skin-lesion depths measured on prebiopsy supine CT scans were significantly larger than those measured on CT scans obtained during TNB in the prone position (p < 0.001; mean difference ± standard deviation (SD), 6.2 ± 5.7 mm; range, 0–18 mm), but the differences showed marginal significance in the supine position (p = 0.051; 3.5 ± 3.9 mm; 0–13 mm). Additionally, the differences were significantly larger for the upper (mean ± SD, 7.8 ± 5.7 mm) and middle (10.1 ± 6.5 mm) lung zones than for the lower lung zones (3.1 ± 3.3 mm) in the prone position (p = 0.011), and were larger for the upper lung zone (4.6 ± 5.0 mm) than for the middle (2.4 ± 2.0 mm) and lower (2.3 ± 2.3 mm) lung zones in the supine position (p = 0.004). Conclusions: Skin-lesion depths measured on prebiopsy supine chest CT scans were inaccurate for TNB in the prone position, particularly for nodules in the upper and middle lung zones.

  7. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  8. Implante subcutáneo de un carcinoma hepatocelular tras la punción aspiración con aguja fina Subcutaneous seeding of hepatocellular carcinoma after fine-needle percutaneous biopsy

    Directory of Open Access Journals (Sweden)

    D. Martínez Ramos

    2007-06-01

    Full Text Available Los implantes subcutáneos son una complicación rara tras la punción aspiración con aguja fina de los carcinomas hepatocelulares. Los autores describen un caso de implante subcutáneo neoplásico en una mujer de 70 años con cirrosis hepática por virus C complicada con un carcinoma hepatocelular. Se efectuó una punción aspiración con aguja fina en el segmento II hepático. El implante tumoral se desarrolló en el trayecto de la punción aspiración. La tumoración subcutánea fue extirpada quirúrgicamente y el estudio anatomopatológico confirmó que se trataba de un carcinoma hepatocelular bien diferenciado.Subcutaneous tumor seeding after fine-needle percutaneous biopsy for hepatocellular carcinoma is a rarely seen complication. The authors describe a case of subcutaneous neoplastic seeding in a 70-year-old woman with chronic hepatitis C virus complicated by hepatocellular carcinoma. Ultrasonically guided fine-needle aspiration biopsy was performed in segment II of the liver. The neoplastic seeding developed along the needle track used to carry out the fine-needle biopsy. The subcutaneous tumor was excised, and histological examination revealed a well-differentiated hepatocellular carcinoma.

  9. Handheld single photon emission computed tomography (handheld SPECT) navigated video-assisted thoracoscopic surgery of computer tomography-guided radioactively marked pulmonary lesions.

    Science.gov (United States)

    Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen

    2016-09-01

    Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the

  10. Learning curve of thyroid fine-needle aspiration biopsy.

    Science.gov (United States)

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Endoscopic ultrasound-guided fine-needle aspiration diagnosis of secondary tumors involving the pancreas: An institution′s experience

    Directory of Open Access Journals (Sweden)

    Ahmed K Alomari

    2016-01-01

    Full Text Available Background: Pancreatic masses may seldom represent a metastasis or secondary involvement by lymphoproliferative disorders. Recognition of this uncommon occurrence may help render an accurate diagnosis and avoid diagnostic pitfalls during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA. In this study, we review our experience in diagnosing secondary tumors involving the pancreas. Materials and Methods: The electronic database of cytopathology archives was searched for cases of secondary tumors involving the pancreas at our institution and a total of 31 cases were identified. The corresponding clinical presentations, imaging study findings, cytological diagnoses, the results of ancillary studies, and surgical follow-up, if available, were reviewed. Results: Nineteen of the patients were male and 12 female, with a mean age of 66 years. Twenty-three patients (74% had a prior history of malignancy, with the latency ranging from 6 months to 19 years. The secondary tumors involving the pancreas included metastatic carcinoma (24 cases, metastatic sarcoma (3 cases, diffuse large B-cell lymphoma (2 cases, and plasma cell neoplasm (2 cases. The most common metastatic tumors were renal cell carcinoma (8 cases and lung carcinoma (7 cases. Correct diagnoses were rendered in 29 cases (94%. The remaining two cases were misclassified as primary pancreatic carcinoma. In both cases, the patients had no known history of malignancy, and no ancillary studies were performed. Conclusions: Secondary tumors involving the pancreas can be accurately diagnosed by EUS-FNA. Recognizing uncommon cytomorphologic features, knowing prior history of malignancy, and performing ancillary studies are the keys to improve diagnostic performance and avoid diagnostic pitfalls.

  12. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Cohen, D.; Bruckheimer, E.; Bachar, G. N.; Konstantinovsky, R.; Birk, E.; Atar, E.

    2016-01-01

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  13. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A. [Soreq NRC, Radiation Protection Domain (Israel); Cohen, D.; Bruckheimer, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Bachar, G. N.; Konstantinovsky, R. [Rabin Medical Center, Department of Diagnostic Radiology (Israel); Birk, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Atar, E., E-mail: elia@clalit.org.il [Rabin Medical Center, Department of Diagnostic Radiology (Israel)

    2016-05-15

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  14. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  15. Ultrasound-Guided Fine Needle Aspiration Cytology in the Assessment of Cervical Metastasis in Patients Undergoing Elective Neck Dissection

    International Nuclear Information System (INIS)

    Dabirmoghaddam, Payman; Sharifkashany, Shervin; Mashali, Leila

    2014-01-01

    In head and neck cancer patients, diagnosis of metastatic cervical adenopathy is essential for treatment planning and prognosis assessment. Treatment of patients with head and neck cancer with clinically negative cervical lymph node (N0) remains controversial. While routine neck treatment would result in overtreatment in many patients, observation may delay the diagnosis and decrease the patients’ survival. To gain insights into the unclear questions regarding the value of diagnostic modalities in patients with N0 neck, this study was designed to compare the diagnostic efficacy of palpation, ultrasonography (US) and ultrasound-guided fine needle aspiration (USGFNA) in detecting cervical lymph node metastasis. Forty-two patients with head and neck cancer who underwent US and USGFNA prior to elective neck dissection were studied. Histopathologic findings of the neck specimens were compared with each diagnostic technique. Of the 53 neck dissection specimens, histopathology showed metastases in 16 cases. The overall accuracy of USGFNA, US and palpation was 96%, 68% and 70%, respectively. The specificity of USGFNA was superior to palpation and US alone. USGFNA had the highest sensitivity, predictive value and accuracy in detecting cervical metastases compared with other performed tests. In our study, USGFNA was superior to palpation and US in detecting metastasis in clinically negative necks. This method can be recommended as a diagnostic tool in preoperative assessment of patients without palpable metastasis, but further investigations are needed before this modality could be considered as an alternative to elective neck dissection

  16. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography.

    Science.gov (United States)

    Ogo, Takeshi; Fukuda, Tetsuya; Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin; Sanda, Yoshihiro; Morita, Yoshiaki; Asano, Ryotaro; Konagai, Nao; Yasuda, Satoshi

    2017-04-01

    Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1year after BPA. Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Stereotaxic Fine-Needle Aspiration Cytologic Evaluation of Non-palpable Breast Lesions

    Directory of Open Access Journals (Sweden)

    M Haghighi

    2005-07-01

    Full Text Available Background: Although long-term mammography is the standard means of evaluation for the probably benign lesions of breast, some times we feel obliged to know about the benignity and the extent of lesions earlier. Therefore we evaluated the diagnostic value of stereotaxic fine-needle aspiration (SFNA in low suspicion breast lesions as an alternative to the routine modality. Methods: The study included 150 low-suspicion or probably benign breast lesions detected on mammography. All cases underwent SFNA and followed by exciosional biopsy or follow-up mammography based on SFNA findings. Results: Fibroadenoma and normal tissue lesions were diagnosed in 57% of patients, in whom no evidence of malignancy was found in the follow-up period. In 48 patients with cytologic findings suggestive of proliferative fibrocystic disease, three cases of malignancy were detected by excisional biopsy. Conclusion: A SFNA result suggesting benignity allows safe clinical follow-up, whereas a suspicious or equivocal diagnosis needs more invasive modalities for further investigations. Key words: Breast, Mammography, Stereotaxic, Fine-Needle Aspiration (FNA

  18. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  19. Guide for the realization of core needle biopsy through stereotaxy in the diagnosis of suspicious breast lesions of malignity

    International Nuclear Information System (INIS)

    Jimenez Zuniga, Jorge Luis

    2012-01-01

    demonstrated to be more precise and to make more accurate the diagnostic evaluation. While, the systems of vacuum-assisted biopsy have allowed the obtention of higher quality cylinders, clearly improving results, especially in cases of microcalcifications. The main indications for the use of stereotaxy in the intervention of the breast are analyzed, among which can be mentioned: fine-needle aspiration biopsy, core needle biopsy and preoperative localization. The technique of fine-needle aspiration biopsy has gained acceptation in the diagnosis of palpable lesions of the breast, the function of this technique in the management of nonpalpable lesions not is completely defined, due to the high percentage of insufficient samples. The systems of core needle biopsy have allowed the obtention of multiple cylinders with great diagnostic reliability, especially in the case of breast nodules. However, its use in microcalcifications has showed false negative results. The preoperative localization through needle in the nonpalpable lesions of the breast, has allowed to the radiologist to provide a guide to the surgeon that has realized the open biopsy, ensuring thus, that surgical procedure can be carried out quickly and with the best possible cosmetic result. The radiological assessment of the breast lesions in mammography are defined, in order to standardize the terminology applied at the time to report studies of the breast, to categorize the lesions according to the level of suspicion and to assign a recommendation to follow in injury determined. Before all nonpalpable breast lesion that has required a biopsy, should be considered first which will be the guidance system most adequate, and second, which is the technique with best diagnostic performing and better relationship cost/effectiveness. The core needle biopsy (CNB) has been a little aggressive technique and highly reliable in the diagnosis of the palpable and nonpalpable lesions. The sensitivity of the CNB has been different

  20. Selective fine needle aspiration of parotid masses. FNA should be performed in all patients older than 60 years.

    LENUS (Irish Health Repository)

    Kieran, S M

    2012-02-01

    OBJECTIVES: The exact role of fine needle aspiration in the pre-operative assessment of patients presenting with parotid masses is controversial. Some surgeons propose that fine needle aspiration be performed only selectively in those patients with likely malignant disease, whilst others recommend it for all patients presenting with such a mass. Intuitively, one would expect older patients to be more likely to suffer from primary malignant parotid tumours and secondary deposits of malignant skin tumours. Therefore, we hypothesised that older patients with a parotid mass should undergo fine needle aspiration regardless of their medical history. DESIGN: We retrospectively reviewed 197 consecutive parotidectomies to test this hypothesis. RESULTS: One hundred and twenty-one patients (61.4 per cent) were diagnosed with benign disease, whilst 76 (38.6 per cent) were diagnosed with malignant disease. Eighty-three per cent of patients aged 60 years or younger had benign disease, as opposed to 35.6 per cent of patients aged more than 60 years. Malignant disease occurred more commonly in patients older than 60 years (odds ratio 8.962, 95 per cent confidence interval 4.607-17.434). CONCLUSION: In patients with a parotid mass, fine needle aspiration should be performed on all those aged 60 years or older.

  1. Evaluation of a mammographic stereotactic device for localization, fine-needle aspiration cytologic studies, and core biopsy of suspicious lesions

    International Nuclear Information System (INIS)

    Fajardo, L.J.; Davey, G.A.

    1988-01-01

    Mammography-guided interventional breast procedures, such as preoperative localization, fine-needle aspiration cytology (FNAC), and core biopsy of suspicious lesions, require accurate three-dimensional localization. The authors have evaluated a prototype stereotactic mammography device for localizing abnormalities with both phantom and clinical studies. Twenty-six localizations on a phantom were within 0.5 mm +- 0.93 (standard deviation) from the lesions; accuracy in clinical procedures was within 0.6 mm +- 0.8. Procedures are performed an average of 8 minutes faster with this device. They are prospectively evaluating mammography-guided FNAC and core biopsy of suspicious lesions in 100 patients. Results of FNAC performed without the stereotactic device agreed with results of open surgical biopsy in six of eight patients; results of core biopsy agreed in seven of eight

  2. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  3. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo

    2017-01-01

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications

  4. Diagnostic accuracy of fine needle aspiration cytology in hepatic tumours

    International Nuclear Information System (INIS)

    Nazir, R.T.; Sharif, M.A.; Iqbal, M.; Amin, M.S.

    2010-01-01

    To determine the diagnostic accuracy of fine-needle aspiration cytology (FNAC) in liver masses to isolate malignant from benign tumours and hepatocellular carcinoma (HCC) from metastatic tumours. Study Design: Cross-sectional, observational. Place and Duration of Study: Department of Histopathology, Combined Military Hospital, Peshawar, from June 2004 to June 2005. Methodology: All the patients with liver masses confirmed by ultrasonography, irrespective of age and gender, were included. Patients with inflammatory lesions were excluded from the study. Selected patients underwent fine-needle aspiration under ultrasound guidance followed by needle biopsy. The cytological slides were stained by haematoxylin and eosin (H and E) stain, while Papanicolaou's stain was employed in selective cases. Needle biopsy fragments were fixed in formalin followed by paraffin embedding and staining with H and E stain. Sensitivity and specificity of FNAC in the diagnosis of liver masses was determined using histological diagnosis on liver biopsy as gold standard. Results: There were one hundred subjects. The mean age at presentation was 55 +- 12 years with male to female ratio of 1.7:1. Cytological diagnosis in 19 cases was benign/non-neoplastic and 81 was malignant. Out of the latter, 49 (60.49%) were HCC and 32 (39.51%) were metastatic tumours on cytology. The overall sensitivity, specificity and accuracy of FNAC in the diagnosis of malignant lesions was 95.2%, 100% and 96% respectively using histological diagnosis on liver biopsy as gold standard. Sensitivity of FNAC to differentiate HCC from metastatic tumours in liver was 96% while specificity was 100% having a diagnostic accuracy of 97.5%. The discrepancy in cyto-histological comparison was mainly seen in well differentiated and poorly-differentiated HCCs. Conclusion: FNAC of the liver masses is a simple, safe, accurate, economical screening test without significant morbidity that can be used to identify the vast majority of

  5. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  6. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  7. Safety and correlation of test results of combined ultrasound-guided fine-needle aspiration and needle core biopsy of the canine spleen.

    Science.gov (United States)

    Watson, Adam T; Penninck, Dominique; Knoll, Joyce S; Keating, John H; Sutherland-Smith, James

    2011-01-01

    The safety and diagnostic value of combined splenic fine-needle aspiration (FNA) and needle core biopsy (NCB) is unknown. Forty-one dogs with splenic lesions were studied prospectively. Safety was assessed in 38 dogs and no complications were encountered. Initially, clinical and anatomic pathologists reviewed each FNA and NCB sample, respectively, without knowledge of the other's results. Diagnoses were categorized as neoplastic, benign, inflammatory, normal, or nondiagnostic. The level of agreement between sampling methods was categorized as complete, partial, disagreement, or not available. Test correlation was performed in 40 dogs. Nondiagnostic results occurred in 5/40 NCB (12.5%) and no FNA samples. Neoplasia was diagnosed in 17/40 dogs (42.5%), benign changes in 20/40 dogs (50%), inflammatory disorders in 0/40 dogs, and normal 2/40 dogs (5%). One of the 40 dogs (2.5%) had a diagnosis that was equivocal for neoplasia on both tests and therefore was not categorized. Of the 35 dogs that had diagnostic samples, cytopathologic and histopathologic diagnoses agreed completely in 18/35 dogs (51.4%), partially in 3/35 dogs (8.6%), and were in disagreement in 14/35 dogs (40.0%). Pathologists collaboratively reviewed diagnoses that were in disagreement or partial agreement and altered their individual diagnoses in 6/17 dogs (35.3%) to be within partial or complete agreement, respectively. Percutaneous FNA and NCB can be performed safely in dogs with sonographic splenic changes. Results suggest that adding NCB to FNA provides complementary information in dogs with suspected splenic neoplasia. This combined protocol may improve detection of splenic neoplasia and provide neoplastic subclassification. © 2010 Veterinary Radiology & Ultrasound.

  8. A technique to improve diagnostic information from fine-needle aspirations: immunohistochemistry on cytoscrape

    DEFF Research Database (Denmark)

    Skov, Birgit Guldhammer; Kiss, Katalin; Ramsted, Julie

    2009-01-01

    BACKGROUND: Cytologic examination of fine-needle aspiration (FNA) material is being used increasingly for the diagnosis of pulmonary lesions. Accurate distinction between nonsmall cell lung cancer (NSCLC), including subgroups, and small cell lung cancer and between primary lung cancer and metasta...

  9. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  10. Pancreatic metastasis in a case of small cell lung carcinoma: Diagnostic role of fine-needle aspiration cytology and immunocytochemistry

    Directory of Open Access Journals (Sweden)

    Dilip K Das

    2011-01-01

    Full Text Available Small cell lung carcinoma represents a group of highly malignant tumors giving rise to early and widespread metastasis at the time of diagnosis. However, the pancreas is a relatively infrequent site of metastasis by this neoplasm, and there are only occasional reports on its fine needle aspiration (FNA cytology diagnosis. A 66-year-old man presented with extensive mediastinal lymphadenopathy and a mass in the pancreatic tail. Ultrasound-guided FNA smears from the pancreatic mass contained small, round tumor cells with extensive nuclear molding. The cytodiagnosis was metastatic small cell carcinoma. Immunocytochemical staining showed that a variable number of neoplastic cell were positive for cytokeratin, chromogranin A, neurone-specific enolase and synaptophysin but negative for leukocyte common antigen. The trans-bronchial needle aspiration was non-diagnostic, but biopsy was suspicious of a small cell carcinoma. This case represents a rare metastatic lesion in the pancreas from small cell lung carcinoma, diagnosed by FNA cytology.

  11. Cytological and sonographic correlation of the biopsies by fine needle aspiration (FNAB) of thyroid nodules in the Hospital San Rafael de Alajuela of July 1, 2006 to February 28, 2007

    International Nuclear Information System (INIS)

    Barrantes Vega, Jesus

    2007-01-01

    The importance of the use of aspiration biopsy with ultrasonic-guided fine needle is recognized as screening method for diagnosis of thyroid nodules. Thyroid nodules are very common, the prevalence of palpitation has been estimated by 4% and 6% by ultrasound. The prevalence in autopsy data of patients with no history of thyroid pathology has been up to 50%. The use set of advanced imaging techniques and modified techniques of biopsy is implemented in order to increase the diagnostic security of thyroid lesions. The incidental finding of thyroid nodules or incidentalomas has soared dizzily, since the advent of ultrasound as an element in the valuation of thyroid disease and thyroid in the neck. Incidence has been reported even up to 40%. A growing number of endocrinologists are using aspiration biopsy with ultrasound guided fine needle of thyroid nodules as initial diagnostic procedure to identify discrete nodules with a direct location. The percentage of malignant nodules or that require surgery by size or symptomatology, generally, is very low, had to be established a systematic approach to reducing morbidity and mortality associated with major surgery of the neck and reduce costs. The biopsy by fine needle aspiration has been a well established diagnostic technique for preoperative evaluation of thyroid nodules, which has led a significant reduction in the number of unnecessary surgeries in most centers has been between 35-75%. This biopsy has been a specific method, sensitive and inexpensive. The sonographic guidance for biopsy by fine needle aspiration offers the following benefits: is safe and inexpensive, able to reduce costs in 25%, minimally invasive and highly effective, this guidance has increased the detection of malignancy of 14 to 39%. Among the complications that can occur is the formation of hematoma and pain, which are rare. On the other hand, the sonographic guidance is essential for biopsy nonpalpable nodules helping to ensure proper placement of

  12. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  13. Preoperative US-guided hook-needle insertion in recurrent lymph nodes of papillary thyroid cancer: A help for the surgeon

    International Nuclear Information System (INIS)

    Duprez, Raphaelle; Lebas, Patrick; Marc, Olivier Saint; Mongeois, Elise; Emy, Philippe; Michenet, Patrick

    2010-01-01

    Objective: The objective of this study is to investigate whether preoperative ultrasound guided insertion of a hook-needle is useful in reoperations for cervical recurrent lymph node metastases of papillary thyroid cancer. Patients and methods: 8 patients with operated papillary thyroid cancer were included in this study. They all had suspicious nonpalpable cervical lymph nodes discovered during follow-up. These lymph nodes were identified by ultrasound imaging and their metastatic nature was confirmed by fine needle aspiration cytology and measurement of in situ thyroglobulin. In all cases, surgical excision of these lymph nodes was decided. All 8 patients had a hook-needle inserted in the suspicious lymph node(s) preoperatively and under ultrasound guidance. Results and conclusion: In all 8 patients, the suspicious lymph nodes were removed and their metastatic nature was confirmed by the final pathological examination. This localization technique is very helpful for the surgeon during the excision of small and nonpalpable lymph nodes, especially in previously operated area.

  14. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS-FNA needles in solid masses

    DEFF Research Database (Denmark)

    Vilmann, Peter; S?ftoiu, Adrian; Hollerbach, Stephan

    2013-01-01

    Few randomized studies have assessed the clinical performance of 25-gauge (25G) needles compared with 22-gauge (22G) needles during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) biopsy of intra-abdominal lesions. We aimed to compare the diagnostic yield, as well as performance...

  15. Needle Decompression in Appalachia Do Obese Patients Need Longer Needles?

    Directory of Open Access Journals (Sweden)

    Carter, Thomas Edward

    2013-11-01

    Full Text Available Introduction: Needle decompression of a tension pneumothorax can be a lifesaving procedure. It requires an adequate needle length to reach the chest wall to rapidly remove air. With adult obesity exceeding one third of the United States population in 2010, we sought to evaluate the proper catheter length that may result in a successful needle decompression procedure. Advance Trauma Life Support (ATLS currently recommends a 51 millimeter (mm needle, while the needles stocked in our emergency department are 46 mm. Given the obesity rates of our patient population, we hypothesize these needles would not have a tolerable success rate of 90%. Methods: We retrospectively reviewed 91 patient records that had computed tomography of the chest and measured the chest wall depth at the second intercostal space bilaterally. Results: We found that 46 mm needles would only be successful in 52.7% of our patient population, yet the ATLS recommended length of 51 mm has a success rate of 64.8%. Therefore, using a 64 mm needle would be successful in 79% percent of our patient population. Conclusion: Use of longer length needles for needle thoracostomy is essential given the extent of the nation’s adult obesity population. [West J Emerg Med. 2013;14(6:650-652.

  16. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  17. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  18. Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-06-01

    Axillary ultrasonography (AUS) and fine-needle aspiration cytology (FNAC) can establish axillary lymph node status before surgery, although this technique is hampered by poor adequacy rates. To achieve consistently high rates of FNAC adequacy, rapid on-site evaluation (ROSE) of FNAC samples was introduced.

  19. Risk of malignancy in fine-needle aspiration biopsy in patients with thyroid nodules

    DEFF Research Database (Denmark)

    Egset, Alice Viktoria; Holm, Camilla; Larsen, Stine Rosenkilde

    2017-01-01

    Introduction: Fine-needle aspiration biopsy (FNAB) is the cornerstone of thyroid nodule evaluation. In most cases, FNAB can discriminate between benign and malignant disease. In other cases, it is only indicative of malignancy and the results are considered “suspicious”. In Denmark, thyroid FNAB...

  20. A foreign body reaction to Surgicel® in a lymph node diagnosed by endobronchial ultrasound-guided transbronchial needle aspiration

    Directory of Open Access Journals (Sweden)

    Diana Badenes

    2017-01-01

    Full Text Available Surgicel ® (Ethicon, North Ryde, NSW, Australia is an absorbable sheet of oxidized cellulose polyanhydroglucuronic acid polymer used as an hemostatic in cardiovascular and thoracic surgery. In some cases, the retained material may cause foreign body granulomatous reactions and simulate tumor recurrence, an abscess, an hematoma, or an infection. We report the case of a 55-year-old patient who was operated of a lung adenocarcinoma. In the thoracic computed tomography scan 1 year after the surgery, a right paratracheal lymph node was detected, so endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA was performed suspecting recurrence of the tumor. The cytology results of the lymph node showed a nonnecrotizing granulomatous reaction secondary to Surgicel ® , used as an hemostatic during the surgery. The objective of presenting this case is to consider foreign body reaction to Surgicel ® in the differential diagnosis of postoperative suspicion of neoplastic recurrence, and on the other hand, to note that EBUS-TBNA enables diagnosis.

  1. Detection of internal mammary lymph node metastasis with {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography in patients with stage III breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Min Jung; Lee, Jong Jin; Kim, Hye Ok; Chae, Sun-Young; Ryu, Jin-Sook; Moon, Dae Hyuk [University of Ulsan College of Medicine, Asan Medical Center, Department of Nuclear Medicine, Songpa-gu, Seoul (Korea, Republic of); Park, Seol Hoon [Ulsan University Hospital, Department of Nuclear Medicine, Ulsan (Korea, Republic of); Ahn, Sei Hyun; Lee, Jong Won; Son, Byung Ho [University of Ulsan College of Medicine, Asan Medical Center, Department of Surgery, Seoul (Korea, Republic of); Gong, Gyung-Yub [University of Ulsan College of Medicine, Asan Medical Center, Department of Pathology, Seoul (Korea, Republic of)

    2014-03-15

    The present study assessed the positive predictive value (PPV) of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the detection of internal mammary node (IMN) metastasis in patients with clinical stage III breast cancer. Patients who were diagnosed with clinical stage III breast cancer and underwent pretreatment {sup 18}F-FDG PET/CT were retrospectively analyzed. The {sup 18}F-FDG PET/CT scans were prospectively reviewed by two board-certified nuclear medicine physicians in a blinded manner. The intensities of IMNs were graded into four categories (no activity and lower, similar, and higher activities than that of the mediastinal blood pool). IMNs were measured from the combined CT (largest diameter of the short axis). Histologic data of the IMNs were obtained by ultrasonography-guided fine-needle aspiration biopsy or surgical excision. The PPV was calculated for pathologically confirmed IMNs. Visual grade, maximum standardized uptake values (SUV{sub max}), and sizes were analyzed according to the pathology results. There were 249 clinical stage III breast cancer patients (age 48.0 ± 10.1 years, range 26-79 years) who had undergone initial {sup 18}F-FDG PET/CT prior to treatment. Excluding 33 cases of stage IV breast cancer, 62 of 216 patients had visible IMNs on {sup 18}F-FDG PET/CT, and histologic confirmation was obtained in 31 patients. There were 27 metastatic and four nonmetastatic nodes (PPV 87.1 %). Metastatic nodes mostly presented with visual grade 3 (83.9 %), and SUV{sub max} and size were 3.5 ± 4.3 and 5.6 ± 2.0 mm, respectively. {sup 18}F-FDG PET/CT has a high PPV for IMN metastasis in clinical stage III breast cancer, indicating the possibility of metastasis in IMNs with FDG uptake similar to/lower than that of the blood pool or small-sized nodes. (orig.)

  2. Development of a guidance guide for dosimetry in computed tomography; Desenvolvimento de um guia orientativo para dosimetria em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Fontes, Ladyjane Pereira

    2016-07-01

    Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR. (author)

  3. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  4. Computed-tomography-guided anatomic standardization for quantitative assessment of dopamine transporter SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kota [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Imabayashi, Etsuko; Matsuda, Hiroshi [National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Sumida, Kaoru; Sone, Daichi; Kimura, Yukio; Sato, Noriko [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); Mukai, Youhei; Murata, Miho [National Center of Neurology and Psychiatry, Department of Neurology, Tokyo (Japan)

    2017-03-15

    For the quantitative assessment of dopamine transporter (DAT) using [{sup 123}I]FP-CIT single-photon emission computed tomography (SPECT) (DaTscan), anatomic standardization is preferable for achieving objective and user-independent quantification of striatal binding using a volume-of-interest (VOI) template. However, low accumulation of DAT in Parkinson's disease (PD) would lead to a deformation error when using a DaTscan-specific template without any structural information. To avoid this deformation error, we applied computed tomography (CT) data obtained using SPECT/CT equipment to anatomic standardization. We retrospectively analyzed DaTscan images of 130 patients with parkinsonian syndromes (PS), including 80 PD and 50 non-PD patients. First we segmented gray matter from CT images using statistical parametric mapping 12 (SPM12). These gray-matter images were then anatomically standardized using the diffeomorphic anatomical registration using exponentiated Lie algebra (DARTEL) algorithm. Next, DaTscan images were warped with the same parameters used in the CT anatomic standardization. The target striatal VOIs for decreased DAT in PD were generated from the SPM12 group comparison of 20 DaTscan images from each group. We applied these VOIs to DaTscan images of the remaining patients in both groups and calculated the specific binding ratios (SBRs) using nonspecific counts in a reference area. In terms of the differential diagnosis of PD and non-PD groups using SBR, we compared the present method with two other methods, DaTQUANT and DaTView, which have already been released as software programs for the quantitative assessment of DaTscan images. The SPM12 group comparison showed a significant DAT decrease in PD patients in the bilateral whole striatum. Of the three methods assessed, the present CT-guided method showed the greatest power for discriminating PD and non-PD groups, as it completely separated the two groups. CT-guided anatomic standardization using

  5. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  6. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  7. Difficulties encountered managing nodules detected during a computed tomography lung cancer screening program.

    Science.gov (United States)

    Veronesi, Giulia; Bellomi, Massimo; Scanagatta, Paolo; Preda, Lorenzo; Rampinelli, Cristiano; Guarize, Juliana; Pelosi, Giuseppe; Maisonneuve, Patrick; Leo, Francesco; Solli, Piergiorgio; Masullo, Michele; Spaggiari, Lorenzo

    2008-09-01

    The main challenge of screening a healthy population with low-dose computed tomography is to balance the excessive use of diagnostic procedures with the risk of delayed cancer detection. We evaluated the pitfalls, difficulties, and sources of mistakes in the management of lung nodules detected in volunteers in the Cosmos single-center screening trial. A total of 5201 asymptomatic high-risk volunteers underwent screening with multidetector low-dose computed tomography. Nodules detected at baseline or new nodules at annual screening received repeat low-dose computed tomography at 1 year if less than 5 mm, repeat low-dose computed tomography 3 to 6 months later if between 5 and 8 mm, and fluorodeoxyglucose positron emission tomography if more than 8 mm. Growing nodules at the annual screening received low-dose computed tomography at 6 months and computed tomography-positron emission tomography or surgical biopsy according to doubling time, type, and size. During the first year of screening, 106 patients underwent lung biopsy and 91 lung cancers were identified (70% were stage I). Diagnosis was delayed (false-negative) in 6 patients (stage IIB in 1 patient, stage IIIA in 3 patients, and stage IV in 2 patients), including 2 small cell cancers and 1 central lesion. Surgical biopsy revealed benign disease (false-positives) in 15 cases (14%). Positron emission tomography sensitivity was 88% for prevalent cancers and 70% for cancers diagnosed after first annual screening. No needle biopsy procedures were performed in this cohort of patients. Low-dose computed tomography screening is effective for the early detection of lung cancers, but nodule management remains a challenge. Computed tomography-positron emission tomography is useful at baseline, but its sensitivity decreases significantly the subsequent year. Multidisciplinary management and experience are crucial for minimizing misdiagnoses.

  8. Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Sedlmair, Martin; Ritter, Christine; Banckwitz, Rosemarie; Flohr, Thomas

    2012-01-01

    Purpose: Computed tomography (CT) fluoroscopy-guided interventions pose relevant radiation exposure to the interventionalist. The goal of this study was to analyze the efficacy of lower-body shielding as a simple structural method for decreasing radiation dose to the interventionalist without limiting access to the patient. Material and Methods: All examinations were performed with a 128-slice dual source CT scanner (12 × 1.2-mm collimation; 120 kV; and 20, 40, 60, and 80 mAs) and an Alderson-Rando phantom. Scatter radiation was measured with an ionization chamber and a digital dosimeter at standardized positions and heights with and without a lower-body lead shield (0.5-mm lead equivalent; Kenex, Harlow, UK). Dose decreases were computed for the different points of measurement. Results: On average, lower-body shielding decreased scatter radiation by 38.2% within a 150-cm radius around the shielding. This decrease is most significant close to the gantry opening and at low heights of 50 and 100 cm above the floor with a maximum decrease of scatter radiation of 95.9% close to the scanner’s isocentre. With increasing distance to the gantry opening, the effect decreased. There is almost no dose decrease effect at ≥150 above the floor. Scatter radiation and its decrease were linearly correlated with the tube current-time product (r 2 = 0.99), whereas percent scatter radiation decrease was independent of the tube current-time product. Conclusion: Lower-body shielding is an effective way to decrease radiation exposure to the interventionalist and should routinely be used in CT fluoroscopy-guided interventions.

  9. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  10. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  11. Conclusiveness of fine needle aspiration in 2419 histologically confirmed benign and malignant breast lesions

    NARCIS (Netherlands)

    Kooistra, B.; Wauters, C.; Wobbes, T.; Strobbe, L.

    2011-01-01

    We aimed to retrospectively assess (1) the conclusiveness of breast fine needle aspiration (FNA) in a histologically confirmed population and (2) the clinical and radiologic determinants of a conclusive diagnosis. Aspirates were diagnosed as inadequate, benign, atypical, suspicious or malignant. We

  12. Experimental study on venography with carbon dioxide by fine-needle direct-puncture of abdominal viscera

    International Nuclear Information System (INIS)

    Zhu Chi; Xu Changliang; Zhang Dezhi; Zheng Feiqun; Sheng Qiang; Zhang Xiuze; Xiong Zhuang; Yu Yongqiang

    2005-01-01

    Objective: To evaluate the feasibility and safety of CO 2 venography by fine-needle direct-puncture of abdominal viscera. Methods: Two healthy female pigs and two healthy female dogs were used in this study. Multi-point punctures of abdominal viscera including liver, spleen, kidney, pancreas, walls of small intestines, and uterus with 25-gauge needle were performed for CO 2 venography in all animals. Diagnostic image quality of the angiographic images was assessed by 3 independent observers. Results: Splenic-portal vein, hepatic vein, portal vein, renal vein and inferior vena cava, uterine vein and ovarian vein could be visualized by fine needle direct CO 2 injection into the related organic parenchyma, while draining vein of small intestines and pancreas could not be shown. Splenic-portal veins were revealed especially well with grade A of 87.5% (7/8) , grade B of 12.5% (1/8), and grade C of 0%. The image quality of hepatic veins were 81.8% (9/11), 18.2% (2/11), and 0% for grade A, B, and C, respectively. The portal veins were 77.8% (7/9), 22.2%(2/9), and 0% for grade A, B, and C, respectively. The renal vein and inferior vena cava were 38.5% (5/13), 61.5% (8/13), and 0% for grade A, B, and C respectively. The uterine veins and ovarian veins were 0%, 33.3% (2/6), and 66.7% (4/6) for grade A, B, and C, respectively. During the CO 2 angiographic procedure, vital signs remained stable in all animals. Conclusion: CO 2 venography with fine-needle direct-puncture of abdominal viscera, excluding small intestines and pancreas, is feasible and safe. (authors)

  13. Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings

    Science.gov (United States)

    Lee, Mi-Jung; Hong, Soon Won; Chung, Woung Youn; Kwak, Jin Young; Kim, Min Jung

    2011-01-01

    Purpose To compare the cytological results of ultrasound-guided fine-needle aspiration (US-FNA) cytology of thyroid nodules to sonographic findings and determine whether US findings are helpful in the interpretation of cytological results. Materials and Methods Among the thyroid nodules that underwent US-FNA cytology, we included the 819 nodules which had a conclusive diagnosis. Final diagnosis was based on pathology from surgery, repeated FNA cytology or follow-up of more than one year. Cytological results were divided into five groups: benign, indeterminate (follicular or Hurthle cell neoplasm), suspicious for malignancy, malignant, and inadequate. US findings were categorized as benign or suspicious. Cytological results and US categories were analyzed. Results Final diagnosis was concluded upon in 819 nodules based on pathology (n=311), repeated FNA cytology (n=204) and follow-up (n=304), of which 634 were benign and 185 were malignant. There were 560 benign nodules, 141 malignant nodules, 49 nodules with inadequate results, 21 with indeterminate results, and 48 that were suspicious for malignancy. The positive and negative predictive values of the US categories were 59.1% and 97.0%, and those of the cytological results were 93.7% and 98.9%. The US categories were significantly correlated with final diagnosis in the benign (p=0.014) and suspicious for malignancy (pcytological result groups, but not in the inadequate and indeterminate cytological results groups. The false positive and negative rates of cytological results were 1.9% and 3.2%. Conclusion Sonographic findings can be useful when used alongside cytological results, especially in nodules with cytological results that are benign or suspicious for malignancy. PMID:21786450

  14. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  15. Image guided percutaneous splenic interventions

    International Nuclear Information System (INIS)

    Kang, Mandeep; Kalra, Naveen; Gulati, Madhu; Lal, Anupam; Kochhar, Rohit; Rajwanshi, Arvind

    2007-01-01

    Aim: The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. Materials and methods: We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous splenic interventions were performed after informed consent in 89 patients: 64 men and 25 women who ranged in age from 5 months to 71 years (mean, 38.4 years) under ultrasound (n = 93) or CT (n = 2) guidance. The procedures performed were fine needle aspiration biopsy of focal splenic lesions (n = 78) and aspiration (n = 10) or percutaneous catheter drainage of a splenic abscess (n = 7). Results: Splenic fine needle aspiration biopsy was successful in 62 (83.78%) of 74 patients with benign lesions diagnosed in 43 (58.1%) and malignancy in 19 (25.67%) patients. The most common pathologies included tuberculosis (26 patients, 35.13%) and lymphoma (14 patients, 18.91%). Therapeutic aspiration or pigtail catheter drainage was successful in all (100%) patients. There were no major complications. Conclusions: Image-guided splenic fine needle aspiration biopsy is a safe and accurate technique that can provide a definitive diagnosis in most patients with focal lesions in the spleen. This study also suggests that image-guided percutaneous aspiration or catheter drainage of splenic abscesses is a safe and effective alternative to surgery

  16. Hyalinizing Granuloma: An Unusual Case of a Pulmonary Mass

    Directory of Open Access Journals (Sweden)

    Viviane Brandão

    2010-01-01

    Full Text Available We describe the case of pulmonary hyalinizing granuloma in a 34-year-old asymptomatic man who presented with a pulmonary nodule apparent by chest radiography and computed tomography (CT. He had a history of previous treatment for tuberculosis. His laboratory data were normal. Bronchoscopy and CT-guided percutaneous transthoracic fine needle aspiration cytology were inconclusive. The diagnosis was revealed after the histopathological examination of an open lung biopsy.

  17. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  18. Efficacy of computed tomography guided radiofrequency ablation forosteoid osteomas in 31 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon; Ahn, Joong Mo; Lee, Joon Woo; Lee, Guen Young; Lee, Eu Gene; Oh, Joo Han; Cho, Hwan Seong; Kang, Heung Sik [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-04-15

    To present the clinical outcome of computed tomography (CT) guided radiofrequency ablation (RFA) for osteoid osteoma. Thirty-one patients (M:F = 23:8, mean age: 20 years, range: 4-54 years) who underwent RFA for clinically suspected osteoid osteoma from May 2004 to December 2013 were retrospectively reviewed. RFA was done in all cases under CT guidance by one of three radiologists in our department. Electronic medical records and images were retrospectively reviewed in all patients. Lesions were located in femur (n = 20), tibia (n = 5), fibula (n = 2), humerus (n = 3), talus (n = 2), and calcaneus (n = 1). On discharge, 27 of 33 cases showed complete remission of pain (82%). One major complication (compartment syndrome) and 2 minor complications (reactive synovitis, minimal skin burn at electrode insertion site) were observed. On the last follow-up (0-78 months, mean: 12.6 months) 27 of 33 cases were successfully treated (82%) and had no more complaints. 3 cases presented remaining pain (9%). In 3 cases relapse occurred (9%) and RFA was repeated in 1 case. The repeated treatment was successful. CT-guided RFA is an effective method for the treatment of osteoid osteoma.

  19. Cytomorphology of nipple discharge and fine needle aspiration of duct papilloma

    Directory of Open Access Journals (Sweden)

    H B Bannur

    2012-01-01

    Full Text Available The primary role of fine needle aspiration (FNA of the breast is the distinction between benign and malignant lesions; but in many cases, additional information may be obtained. The major breast lesions that yield papillary fragments on FNA are papillary carcinoma, papilloma, fibroadenoma, and invasive ductal carcinoma that have a papillary component. We present cytomorphological features of nipple discharge and FNA of breast lump in a 32-year female.

  20. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions  .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Fine-needle aspiration cytology in children with superficial lymphadenopathy

    Directory of Open Access Journals (Sweden)

    F. De Corti

    2014-04-01

    Full Text Available Introduction: In pediatric population Fine-Needle Aspiration Citology (FNAC is slowly gaining acceptance in clinical management of Superficial Lymphadenopathy (SL. Our experience adds some data about the usefulness of this technique in diagnosing the cause of a SL and therefore guiding further treatment. Patients and Methods: 238 FNAC were performed in 217 patients with SL, observed at our Institution from 2002 to 2006. The neck was the most frequent localization. The results were available within few hours. In cases of granulomatous findings, the samples were processed for microbiological and PCR test, in order to identify Mycobacteria. Results: 174 were reactive lesions, 38 granulomatous lymphadenopathies, 24 malignant lesions, 2 specimens inadequate for diagnosis. Among the 174 reactive SL, 22 required an incisional biopsy after 1 month follow-up. Among the granulomatous lymphadenopathies, 13 children with Cat-Scratch Disease recovered, 25 with Mycobacteria infection underwent surgical excision. For 24 malignant lesions, the diagnosis was confirmed by further biopsy. Two false negative and no false positive were detected (sensitivity 92%, specificity 100%. No complications were encountered. Conclusions: In our experience FNAC, performed by experienced cytopathologist, has revealed to be a fast, safe, non invasive and inexpensive method to achieve diagnosis in persistent SL. The use of FNAC gave us the possibility to select patients for further investigation and/or surgical treatment. Incisional biopsy remains necessary to confirm the diagnosis in case of malignancy or doubtful lesions.

  2. Two-miRNA classifiers differentiate mutation-negative follicular thyroid carcinomas and follicular thyroid adenomas in fine needle aspirations with high specificity

    DEFF Research Database (Denmark)

    Stokowy, Tomasz; Wojtas, Bartosz; Jarzab, Barbara

    2016-01-01

    Diagnosis of thyroid by fine needle aspiration is challenging for the "indeterminate" category and can be supported by molecular testing. We set out to identify miRNA markers that could be used in a diagnostic setting to improve the discrimination of mutation-negative indeterminate fine needle...... aspirations. miRNA high-throughput sequencing was performed for freshly frozen tissue samples of 19 RAS and PAX8/PPARG mutation-negative follicular thyroid carcinomas, and 23 RAS and PAX8/PPARG mutation-negative follicular adenomas. Differentially expressed miRNAs were validated by quantitative polymerase...... chain reaction in a set of 44 fine needle aspiration samples representing 24 follicular thyroid carcinomas and 20 follicular adenomas. Twenty-six miRNAs characterized by a significant differential expression between follicular thyroid carcinomas and follicular adenomas were identified. Nevertheless...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  4. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@umcutrecht.nl; Maenhout, Metha; Lagendijk, Jan J. W.; Vulpen, Marco van; Moerland, Marinus A. [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Denis de Senneville, Baudouin [Imaging Division, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX, The Netherlands and IMB, UMR 5251 CNRS/University of Bordeaux, Talence 33400 (France); Hautvast, Gilion; Binnekamp, Dirk [Philips Group Innovation Biomedical Systems, Eindhoven 5656 AE (Netherlands)

    2016-10-15

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position

  5. Iterative reconstruction for x-ray computed tomography using prior-image induced nonlocal regularization.

    Science.gov (United States)

    Zhang, Hua; Huang, Jing; Ma, Jianhua; Bian, Zhaoying; Feng, Qianjin; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2014-09-01

    Repeated X-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the X-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as "PWLS-PINL". Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive overrelaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection, and edge detail preservation.

  6. Use of percutaneous image-guided coaxial core-needle biopsy for diagnosis of intraabdominal lymphoma

    International Nuclear Information System (INIS)

    Shimizu, Ikuo; Okazaki, Yoichi; Takeda, Wataru; Kirihara, Takehiko; Sato, Keijiro; Fujikawa, Yuko; Ueki, Toshimitsu; Hiroshima, Yuki; Sumi, Masahiko; Ueno, Mayumi; Ichikawa, Naoaki; Kobayashi, Hikaru

    2014-01-01

    Although pathological diagnosis is essential for managing malignant lymphoma, intraabdominal lesions are generally difficult to approach due to the invasiveness of abdominal surgery. Here, we report the use of percutaneous image-guided coaxial core-needle biopsy (CNB) to obtain intraabdominal specimens for diagnosing intraabdominal lymphomas, which typically requires histopathological and immunohistochemical evaluation. We retrospectively reviewed consecutive cases involving computed tomography (CT)- or ultrasonography (US)-guided CNB to obtain pathological specimens for intraabdominal lesions from 1999 to 2011. Liver, spleen, kidney, and inguinal node biopsies were excluded. We compared CNBs with laparotomic biopsies. A total of 66 CNBs were performed for 59 patients (32 males, 27 females; median age, 63.5), including second or third repeat procedures. Overall diagnostic rate was 88.5%. None of the patients required additional surgical biopsies. Notably, the median interval between recognition of an intraabdominal mass and biopsy was only 1 day. Forty-five procedures were performed for hematological malignancies. Adequate specimens were obtained for histopathological diagnosis in 86% of cases. Flow cytometry detected lymphoma cells in 79.5% of cases. Twelve patients (nine males, three females; median age, 60) were eligible for surgical biopsy. While every postoperative course was satisfactory, median duration from lesion recognition to therapy initiation for lymphoma cases was significantly shorter for CNB than for surgical biopsy (14 vs. 35 days). While one-fourth of the patients were not eligible for the procedures, CNB is safe and highly effective for diagnosis of intraabdominal lymphomas. This method significantly improves sampling and potentially helps attain immunohistological distinction, allowing for more timely therapy initiation

  7. Computed tomography and the TNM classification of lung cancer

    International Nuclear Information System (INIS)

    Sparup, J.; Friis, M.; Brenoee, J.; Vejlsted, H.; Villumsen, B.; Olesen, K.P.; Borgeskov, S.; Bertelsen, S.

    1990-01-01

    Computed tomography (CT)of the thorax and upper abdomen was prospectively evaluated in 84 patients with potentially operable lung cancer. Invasion into the thoracic wall and the mediastinal structures was not accurately demonstrated by CT. For metastatic mediastinal lymph nodes, the sensitivity and specificity of CT were, respectively, 86 per cent and 61 per cent and the positive and negative predictive indices 49 per cent and 91 per cent. For T1, T2 and T3 tumours the negative indices were 100 per cent, 96 per cent and 71 per cent. Positive predictive index did not differ between squamous cell carcinoma and adenocarcinoma. Adrenal metastases were CT-suspected in 17 cases and liver metastases in eight, but were verified by ultrasonography in only one and four cases. CT should be used in preoperative investigation of lung cancer, irrespective of stage. Demonstration of thoracic-wall or mediastinal invasion need not exclude tumour resection. Preoperative mediastinoscopy is indicated if CT shows nodal metastases or if there are signs of tumour invasion, but not in CT-negative T1 or T2 tumour. Abdominal metastases indicated by CT should be investigated with CT-guided needle biopsy. (authors)

  8. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  9. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  10. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  11. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    Science.gov (United States)

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  12. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  13. Diagnostic accuracy of percutaneous cytodiagnosis of hepatic masses, by ultrasound guided fine needle aspiration cytology

    International Nuclear Information System (INIS)

    Asghar, F.; Riaz, S.

    2010-01-01

    Objective: To evaluate the diagnostic accuracy, usefulness and limitations of ultrasound guided FNAC of hepatic masses. Design: Cross - sectional analytical (comparative study). Place and Duration: Department of histopathology, Sheikh Zayed Hospital, Lahore. Study period 1 year. Material and Methods: A total of 32 patients with solitary or multiple hepatic masses underwent FNAC from March 1999 to March 2000. Adequate aspirates were obtained in all these cases. Smears were stained with May-Grunwald Giemsa, Haematoxylin and Eosin and Papanicolaou stain. Needle biopsies from the same cases were also obtained and processed. These were stained with routine Haematoxylin and Eosin staining. The blood clots obtained during FNAC were fixed in 10% neu-tral buffered formalin. The histopathology of these blood clots was used for cases whose needle core biopsy was not available. The screened FNAC smears were divided into 3 categories i.e., benign (group - I), malignant (group - II), non-neoplastic / inflammatory lesions (including cysts and abscesses) (group - III). Results: Out of 32 cases, 6 were categorized as benign, 18 as malignant, and 8 as non-neoplastic inflammatory lesions. Three false negative diagnoses, including 1 for malignant tumour and 2 for benign tumours was obtained. There was 1 false positive diagnosis for malignancy. FNAC - histological correlation showed a 94.2% sensitivity and 92.3% diagnostic accuracy for malignant tumours, while benign tumours posed maximum diagnostic problems, giving a 66.67% sensitivity and 85.7% diagnostic accuracy. FNAC picked up correctly all the non-neoplastic lesions giving a 100% sensitivity and diagnostic accuracy. Conclusion: Majority of the malignant tumours can be categorized on FNAC, with a high degree of accuracy, while benign tumours should be subjected to biopsy, as there is a relatively greater possibility of false negative diagnosis. (author)

  14. Does the Primary Imaging Modality-Computed Tomography or Magnetic Resonance Imaging-Influence Stroke Physicians' Certainty on Whether or Not to Give Thrombolysis to Randomized Acute Stroke Patients?

    DEFF Research Database (Denmark)

    Hansen, Christine Krarup; Christensen, Anders; Rodgers, Helen

    2018-01-01

    BACKGROUND: Door-to-needle time of 20 minutes to stroke patients with intravenous tissue plasminogen activator (iv-tPA) is feasible when computed tomography (CT) is used as first-line of brain imaging. Magnetic resonance imaging (MRI)-based assessment is more time-consuming but superior in detect......BACKGROUND: Door-to-needle time of 20 minutes to stroke patients with intravenous tissue plasminogen activator (iv-tPA) is feasible when computed tomography (CT) is used as first-line of brain imaging. Magnetic resonance imaging (MRI)-based assessment is more time-consuming but superior...

  15. CT guided celiac plexus and splanchnic nerve neurolysis : the modified anterior approach

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Mi Suk; Ym, Seong Hee; Lee, Jin Hee

    1997-01-01

    Since it was first described by Kappis, celiac plexus neurolysis (CPN) has been performed under fluoroscopic guidance by anesthetists or surgeons for the relief of intractable pain caused by upper abdominal malignancy. Recently, however, several groups have reported a computed tomography (CT)-guided technique that increased the safety of the blocking procedure and improved its results. The authors present a new technique CT-guided celiac plexus and splanchic nerve block, to be used simultaneously with a modified anterior approach. Using CT to guide needle tip placement, an anterior approach that permitted direct neurolysis of the celiac ganglia and splanchnic nerve was developed

  16. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    OpenAIRE

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial...

  17. Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations

    Science.gov (United States)

    Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian; Kato, Takahisa; King, Franklin; Tuncali, Kemal; Hata, Nobuhiko

    2018-04-01

    Patient-mounted needle guide devices for percutaneous ablation are vulnerable to patient motion. The objective of this study is to develop and evaluate a software system for an MRI-compatible patient-mounted needle guide device that can adaptively compensate for displacement of the device due to patient motion using a novel image-based automatic device-to-image registration technique. We have developed a software system for an MRI-compatible patient-mounted needle guide device for percutaneous ablation. It features fully-automated image-based device-to-image registration to track the device position, and a device controller to adjust the needle trajectory to compensate for the displacement of the device. We performed: (a) a phantom study using a clinical MR scanner to evaluate registration performance; (b) simulations using intraoperative time-series MR data acquired in 20 clinical cases of MRI-guided renal cryoablations to assess its impact on motion compensation; and (c) a pilot clinical study in three patients to test its feasibility during the clinical procedure. FRE, TRE, and success rate of device-to-image registration were mm, mm, and 98.3% for the phantom images. The simulation study showed that the motion compensation reduced the targeting error for needle placement from 8.2 mm to 5.4 mm (p  <  0.0005) in patients under general anesthesia (GA), and from 14.4 mm to 10.0 mm () in patients under monitored anesthesia care (MAC). The pilot study showed that the software registered the device successfully in a clinical setting. Our simulation study demonstrated that the software system could significantly improve targeting accuracy in patients treated under both MAC and GA. Intraprocedural image-based device-to-image registration was feasible.

  18. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  19. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  20. Value of fine-needle aspiration biopsy of salivary gland lesions

    DEFF Research Database (Denmark)

    Christensen, Rikke Kølby; Bjørndal, Kristine; Godballe, Christian

    2010-01-01

    BACKGROUND: The aim of this study was to assess the utility of fine-needle aspiration biopsy (FNAB) in the diagnosis and treatment planning of the lesions of the salivary gland. METHODS: Eight hundred seventy-nine aspiration biopsies of the lesion of the salivary gland over a 10-year period, from...... was 98%, and the negative predictive value was 97%. The overall accuracy was 93%. The correct subtyping of the benign lesions was 97%, and the exact type-specific concordance of the malignant lesions was 71%. CONCLUSION: Considerable benefit to the patient may result from the cautious use of FNAB...

  1. Patterns of lymphadenopathy on fine needle aspiration cytology in eastern Nepal

    Directory of Open Access Journals (Sweden)

    N Mainali

    2015-09-01

    Full Text Available BACKGROUND: Lymphadenopathy is a commonly encountered clinical problem. Fine needle aspiration cytology offers the alternative of an immediate, preliminary, although not always specific diagnosis with little trauma and cost, thus providing ample information for further management and reduce the amount of open biopsy.MATERIAL AND METHODS:  FNAC was performed using 21 gauge needle attached with 10ml disposable needle. Slides were prepared, two were air dried and stained with field stain where as two were fixed in ethanol and was stained with PAP stain. One slide was stained with Ziehl-Neelson stain. Field and PAP stained slide were reviewed and diagnosed by Pathologist.RESULT: Out of the 225 patients, reactive lymphadenitis was the most common diagnosis (54.2%, followed by tubercular lymphadenitis (33.44%. Among the age group percentage of tubercular lymphadenitis was more in 210-30 years of age.  Majority of the metastatic carcinoma was in cervical region, comprising mainly squamous cell carcinoma.CONCLUSION: Reactive lymphadenitis was the most common cause of lymphadenopathy especially in case of children. In case of older population, definite pathology for lymph node enlargement was found in most of the cases. Hence FNAC is warranted in lymphadenopathy, as it is simple yet of great diagnostic value.

  2. Fine needle aspiration cytology of dermal cylindroma

    Directory of Open Access Journals (Sweden)

    Parikshaa Gupta

    2014-01-01

    Full Text Available In this paper, we have described fine needle aspiration cytology (FNAC of a rare case of dermal cylindroma. A 40-year-old female presented with a lateral mid-cervical swelling fixed to the skin. FNAC smears showed multiple clusters of small, round to oval cells with hyperchromatic nuclei, inconspicuous nucleoli and scant cytoplasm. In addition, the background showed deposits of basement membrane type material. This was dark magenta colored pinkish globular material. The globules were occasionally surrounded by the basal type of cells. Occasional cells with elongated nuclei were also noted. Cytological diagnosis of skin adnexal tumor possibly cylindroma was offered. Subsequent histopathology of the swelling showed sheets and clusters of cells in a jigsaw puzzle-like fashion. Deposition of abundant basement membrane-like material was noted in between the tumor cells. A diagnosis of cylindorma was offered. FNAC along with the subcutaneous location of the tumor and absence of primary salivary gland tumor may help to diagnose such rare case.

  3. Application of positron emission tomography-computed tomography in the diagnosis of pulmonary ground-glass nodules.

    Science.gov (United States)

    Hu, Lili; Pan, Yuanwei; Zhou, Zhigang; Gao, Jianbo

    2017-11-01

    The aim of the present study was to investigate the value of positron emission tomography-computed tomography (PET-CT) using 18 F-fluorodeoxyglucose in the clinical diagnosis of pulmonary ground-glass nodule. In total, 54 patients with pulmonary GGN that were identified by PET-CT examination were selected and confirmed by pathology and clinical diagnosis in hospital between April 2014 and April 2015. The association between PET-CT findings and pathology, and the value of PET-CT were then evaluated. In the 54 patients, solitary pulmonary GGN with a nodule diameter of between 0.6 and 2.0 cm were detected. Amongst them, the PET-CT examination of 42 patients revealed hyper metabolic nodules, and were all mixed GGN type nodules with a diameter >1 cm. The PET-CT examination of the remaining 12 patients demonstrated no evidence of metabolic abnormalities and the nodules in these patients were pure or mixed GGN with a diameter <1 cm (except 2 cases with a diameter ≥1 cm). Furthermore, the diagnoses for all patients were pathologically confirmed by CT-guided needle biopsy or thoracoscopic surgical resection. Amongst them, there were 41 cases of lung adenocarcinoma, 4 cases of fungal infection, 7 cases of inflammation and 2 cases of adenomatoid hyperplasia. Additionally, PET-CT has a lower detection rate for smaller GGN exhibits no clear advantage for pure GGN, but has a higher detection rate for larger GGN. In conclusion, to a certain extent, PET-CT makes up for the shortcomings of traditional imaging and has some clinical value for the diagnosis of GGN.

  4. Compressed sensing electron tomography of needle-shaped biological specimens – Potential for improved reconstruction fidelity with reduced dose

    Energy Technology Data Exchange (ETDEWEB)

    Saghi, Zineb, E-mail: saghizineb@gmail.com [Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS (United Kingdom); Divitini, Giorgio [Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS (United Kingdom); Winter, Benjamin [Center for Nanoanalysis and Electron Microscopy (CENEM), Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 6, 91058 Erlangen (Germany); Leary, Rowan [Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS (United Kingdom); Spiecker, Erdmann [Center for Nanoanalysis and Electron Microscopy (CENEM), Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 6, 91058 Erlangen (Germany); Ducati, Caterina [Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS (United Kingdom); Midgley, Paul A., E-mail: pam33@cam.ac.uk [Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge CB3 0FS (United Kingdom)

    2016-01-15

    Electron tomography is an invaluable method for 3D cellular imaging. The technique is, however, limited by the specimen geometry, with a loss of resolution due to a restricted tilt range, an increase in specimen thickness with tilt, and a resultant need for subjective and time-consuming manual segmentation. Here we show that 3D reconstructions of needle-shaped biological samples exhibit isotropic resolution, facilitating improved automated segmentation and feature detection. By using scanning transmission electron tomography, with small probe convergence angles, high spatial resolution is maintained over large depths of field and across the tilt range. Moreover, the application of compressed sensing methods to the needle data demonstrates how high fidelity reconstructions may be achieved with far fewer images (and thus greatly reduced dose) than needed by conventional methods. These findings open the door to high fidelity electron tomography over critically relevant length-scales, filling an important gap between existing 3D cellular imaging techniques. - Highlights: • On-axis electron tomography of a needle-shaped biological sample is presented. • A reconstruction with isotropic resolution is achieved. • Compressed sensing methods are compared to conventional reconstruction algorithms. • High fidelity reconstructions are achieved with greatly undersampled datasets.

  5. Compressed sensing electron tomography of needle-shaped biological specimens – Potential for improved reconstruction fidelity with reduced dose

    International Nuclear Information System (INIS)

    Saghi, Zineb; Divitini, Giorgio; Winter, Benjamin; Leary, Rowan; Spiecker, Erdmann; Ducati, Caterina; Midgley, Paul A.

    2016-01-01

    Electron tomography is an invaluable method for 3D cellular imaging. The technique is, however, limited by the specimen geometry, with a loss of resolution due to a restricted tilt range, an increase in specimen thickness with tilt, and a resultant need for subjective and time-consuming manual segmentation. Here we show that 3D reconstructions of needle-shaped biological samples exhibit isotropic resolution, facilitating improved automated segmentation and feature detection. By using scanning transmission electron tomography, with small probe convergence angles, high spatial resolution is maintained over large depths of field and across the tilt range. Moreover, the application of compressed sensing methods to the needle data demonstrates how high fidelity reconstructions may be achieved with far fewer images (and thus greatly reduced dose) than needed by conventional methods. These findings open the door to high fidelity electron tomography over critically relevant length-scales, filling an important gap between existing 3D cellular imaging techniques. - Highlights: • On-axis electron tomography of a needle-shaped biological sample is presented. • A reconstruction with isotropic resolution is achieved. • Compressed sensing methods are compared to conventional reconstruction algorithms. • High fidelity reconstructions are achieved with greatly undersampled datasets.

  6. Design and analysis of a tendon-based computed tomography-compatible robot with remote center of motion for lung biopsy.

    Science.gov (United States)

    Yang, Yunpeng; Jiang, Shan; Yang, Zhiyong; Yuan, Wei; Dou, Huaisu; Wang, Wei; Zhang, Daguang; Bian, Yuan

    2017-04-01

    Nowadays, biopsy is a decisive method of lung cancer diagnosis, whereas lung biopsy is time-consuming, complex and inaccurate. So a computed tomography-compatible robot for rapid and precise lung biopsy is developed in this article. According to the actual operation process, the robot is divided into two modules: 4-degree-of-freedom position module for location of puncture point is appropriate for patient's almost all positions and 3-degree-of-freedom tendon-based orientation module with remote center of motion is compact and computed tomography-compatible to orientate and insert needle automatically inside computed tomography bore. The workspace of the robot surrounds patient's thorax, and the needle tip forms a cone under patient's skin. A new error model of the robot based on screw theory is proposed in view of structure error and actuation error, which are regarded as screw motions. Simulation is carried out to verify the precision of the error model contrasted with compensation via inverse kinematics. The results of insertion experiment on specific phantom prove the feasibility of the robot with mean error of 1.373 mm in laboratory environment, which is accurate enough to replace manual operation.

  7. Fine needle aspiration diagnosis of a spontaneously infarcted fibroadenoma mimicking carcinoma: a case report.

    Science.gov (United States)

    Arora, Rajan; Abou-Bakr, Amany; Al Taleb, Ahmed

    2013-02-01

    Spontaneous infarction of fibroadenoma is an extremely rare complication in a nonpregnant/nonlactating female undergoing first-time aspiration. It can be misdiagnosed as carcinoma in all aspects of triple approach used for evaluation of patients with breast lesions. A 37-year-old woman presented to the outpatient surgical clinic with a 6-month history of a breast lump that was slowly increasing in size and had become painful during the past month. There was no history of any trauma or fine needle aspiration, and she was not pregnant or lactating. Mammogram and ultrasound revealed a 2.9-cm heterogenous hypoechoic suspicious lesion. No lymph nodes were detected in the axilla. Fine needle aspiration cytology was performed, and a diagnosis of benign breast lesion with features of infarction was rendered on cytology. The lump was excised surgically, and a histological diagnosis of infarcted fibroadenoma was made. Careful and diligent search for preserved benign epithelial cells on smears is the key to recognize this entity and avoid serious therapeutic implications.

  8. CASE REPORT:Chondrosarcoma of Rib on Fine Needle Aspiration Cytology – A Rare Site

    Directory of Open Access Journals (Sweden)

    Prakash M Patil

    2012-07-01

    Full Text Available Background: Fine needle aspiration cytology (FNAC is effective in the diagnosis of bone tumors when combined with careful radiologic and clinical evaluation. Chondrosarcomas often arise in the pelvis or bones of the trunk, but primary chest wall (rib chondrosarcomas are relatively rare. Case Reports: This is a case of a patient with a chondrosarcoma arising in the left lower rib who underwent resection. The patient was a 30-year-old man with a 10x8x6cm tumor in the anterior chest wall of the left side lower rib. On Fine Needle Aspiration Cytology (FNAC of the mass on the anterior chest wall, a diagnosis of a low grade chondrosarcoma was made. This was confirmed histopathologically as a dedifferentiated chondrosarcoma. Macroscopically on excision of gray to pink lobulated mass with adjacent soft tissue and bone with foci of hemorrhage and necrosis the mass measured (M 10x 8x 6 cm. Incidence of chondrosarcoma peaks in the 5th to 6th decade and most commonly involves the femur, humerus, pelvis, and scapula. It rarely involves rib.

  9. Automated Real-Time Needle-Guide Tracking for Fast 3-T MR-guided Transrectal Prostate Biopsy: A Feasibility Study

    NARCIS (Netherlands)

    Zamecnik, P.; Schouten, M.G.; Krafft, A.J.; Maier, F.; Schlemmer, H.-P.; Barentsz, J.O.; Bock, M. de; Futterer, J.J.

    2014-01-01

    Purpose To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation (POCC) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. Materials and Methods This study was approved by the ethics review

  10. Testicular fine-needle aspiration for the assessment of intratesticular hormone concentrations

    Directory of Open Access Journals (Sweden)

    Ada P Lee

    2016-01-01

    Full Text Available Measurement of intratesticular sex steroid concentrations in men informs both the development of male hormonal contraceptives and the understanding of male infertility. Given the challenges of using invasive techniques to measure testicular hormone physiology, our group has used a minimally-invasive fine-needle aspiration technique to measure intratesticular hormones in normal healthy men. Herein, we present a post-hoc analysis of the safety and efficacy of testicular fine-needle aspiration (FNA completed as part of six clinical trials. From 2001 through 2011, a total of 404 procedures were conducted among 163 research volunteers, 85.9% of which were successful in obtaining sufficient fluid for the measurement of intratesticular steroid concentrations. Pain was the most common side effect, with 36.8% of procedures associated with moderate procedural pain and 4.7% with severe procedural pain. Postprocedural pain was uncommon and abated within a few days. Mild local bruising occurred with 14.9% of procedures. Two serious adverse events (0.5% required surgical intervention. The risk of an adverse event was not associated with age, body mass index, testicular size, or the volume of fluid aspirated. Testicular FNA to obtain fluid for measurement of intratesticular steroid concentrations frequently causes mild to moderate procedural pain, but serious adverse events occur rarely. Testicular FNA has been instrumental for defining human intratesticular hormone physiology and is a minimally-invasive, safe, effective method for obtaining fluid for research on testicular physiology and pathology.

  11. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.

    2013-01-01

    Aim: To assess the accuracy and risk factors for complications of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for small (≤20 mm) pulmonary lesions. Materials and methods: A retrospective study was undertaken comprising 169 patients who underwent CT-guided CNB for small (≤20 mm) pulmonary lesions. To assess the accuracy of the procedure, the diagnosis at biopsy was compared with the diagnosis after definitive surgery or clinical follow-up. The risk factors for pneumothorax and bleeding were determined by multivariate analysis of variables. Results: The overall diagnostic accuracy was 93.5%. The sensitivity for malignancy and specificity for benign lesions were 90.4% and 100%, respectively. Positive and negative predictive values were 100% and 83.3%, respectively. Twenty-five patients (14.8%) had pneumothorax after CT percutaneous CNB of the lung. The significant risk factors affecting the incidence of pneumothorax were lesion–pleural distance (p = 0.008) and needle–pleural angle (p = 0.012). The highest rate of pneumothorax correlated with a lesion–pleural distance ≥21 mm (OR = 18.46; 95%CI: 2.27–149.95) and a needle–pleural angle ≥51° (OR = 8.22; 95%CI: 2.14–31.49). Bleeding occurred in 30 patients (17.8%). The only significant risk factor affecting the incidence of bleeding was lesion–pleural distance (p = 0.011). The highest bleeding rate correlated with a lesion–pleural distance ≥21 mm (OR = 7.93; 95%CI: 1.73–36.43). Conclusion: CT-guided percutaneous CNB of small (≤20 mm) pulmonary lesions provides high diagnostic accuracy with acceptable complications. A lesion–pleural distance of ≥21 mm and needle–pleural angle of ≥51° are identified as the risk factors for highest pneumothorax rate. In addition, the needle–pleural angle is a novel predictor of pneumothorax. A lesion–pleural distance of ≥21 mm is also identified as a risk factor for the highest bleeding rate.

  12. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.

    Science.gov (United States)

    Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron

    2017-11-01

    The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion

  13. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  15. Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

    Science.gov (United States)

    Brunner, Stephen; Nett, Brian E; Tolakanahalli, Ranjini; Chen, Guang-Hong

    2011-02-21

    X-ray scatter is a significant problem in cone-beam computed tomography when thicker objects and larger cone angles are used, as scattered radiation can lead to reduced contrast and CT number inaccuracy. Advances have been made in x-ray computed tomography (CT) by incorporating a high quality prior image into the image reconstruction process. In this paper, we extend this idea to correct scatter-induced shading artifacts in cone-beam CT image-guided radiation therapy. Specifically, this paper presents a new scatter correction algorithm which uses a prior image with low scatter artifacts to reduce shading artifacts in cone-beam CT images acquired under conditions of high scatter. The proposed correction algorithm begins with an empirical hypothesis that the target image can be written as a weighted summation of a series of basis images that are generated by raising the raw cone-beam projection data to different powers, and then, reconstructing using the standard filtered backprojection algorithm. The weight for each basis image is calculated by minimizing the difference between the target image and the prior image. The performance of the scatter correction algorithm is qualitatively and quantitatively evaluated through phantom studies using a Varian 2100 EX System with an on-board imager. Results show that the proposed scatter correction algorithm using a prior image with low scatter artifacts can substantially mitigate scatter-induced shading artifacts in both full-fan and half-fan modes.

  16. Comparison of needles size in pediatric renal biopsy with sono-guided percutaneous-automated gun technique

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Park, Jin Yong

    1997-01-01

    To compare the efficacy of a 20-gauge and an 18-gauge needle in sono-guided percutaneous automated gun biopsy for establishing the specific diagnosis of renal parenchymal disease in pediatric kidneys. In 60 pediatric patients with renal parenchymal diseases, percutaneous sono-guided gun biopsy was performed by an experienced radiologist. In two groups of 30 patients, regardless of their age, two needle passes were performed, using alternately an 18-gauge or a 20-gauge biopsy needle. The core of renal tissue thus obtained was examined with light, immunofluorescent or electron microscopy by the renal pathologist. The mean number of intact glomeruli of whole tissue core per biopsy, as seen on the light microscopy, and post-bioptic complications were compared between the two different needle size groups. The number (mean±1 standard deviation) of glomeruli obtained per biopsy was 17±8 in the 18-gauge needle group, and 14±5 in the 20-gauge group. Between two groups, there was no major post-bioptic complication requiring specific treatment, nor a statistically significant difference in the frequency of minor complications. Even though more glomeruli were obtained with an 18-gauge needle, the number obtained with a 20-gauge needle also permitted adequate pathologic examination. Both an 18-gauge and a 20-gauge needle may thus be suitable for renal biopsy in pediatric patients

  17. Harmonic Contrast-Enhanced Endoscopic Ultrasonography for the Guidance of Fine-Needle Aspiration in Solid Pancreatic Masses

    DEFF Research Database (Denmark)

    Seicean, A; Badea, R; Moldovan-Pop, A

    2015-01-01

    Purpose: The global accuracy of fine-needle aspiration guided by endoscopic ultrasound (EUS-FNA) for pancreatic adenocarcinoma is about 85 %. The use of contrast agents during EUS to highlight vessels and the necrotic parts of pancreatic masses may improve biopsy guidance. Our aim was to assess...... whether the guidance of FNA by harmonic contrast-enhanced endoscopic ultrasound (CH-EUS) would increase diagnostic accuracy relative to conventional EUS-FNA in the same pancreatic masses. Patients and Methods: In a prospective study, EUS-FNA was performed in patients with pancreatic masses on CT scan......, followed by harmonic CH-EUS using SonoVue. A second cluster of CH-EUS-FNA was performed on contrast-enhanced images. The final diagnosis was based on the results of EUS-FNA and surgery, or the findings after 12 months' follow-up. Results: The final diagnosis was adenocarcinoma (n = 35), chronic...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  20. CT and MRI-based door-needle-times for acute stroke patients a quasi-randomized clinical trial

    DEFF Research Database (Denmark)

    Hansen, Christine Krarup; Christensen, Anders; Rodgers, Helen

    2017-01-01

    OBJECTIVES: Door-Needle-times (DNT) of 20min are feasible when Computer Tomography (CT) is used for first-line brain-imaging to assess stroke-patients' eligibility for intravenous-tissue-Plasminogen-Activator (iv-tPA), but the more time-consuming Magnetic Resonance Imaging (MRI)-based-evaluation ......OBJECTIVES: Door-Needle-times (DNT) of 20min are feasible when Computer Tomography (CT) is used for first-line brain-imaging to assess stroke-patients' eligibility for intravenous-tissue-Plasminogen-Activator (iv-tPA), but the more time-consuming Magnetic Resonance Imaging (MRI...

  1. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  2. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shirvani, Shervin M.; Komaki, Ritsuko; Heymach, John V.; Fossella, Frank V.; Chang, Joe Y.

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non–small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39–86). The median follow-up duration was 21 months (range, 4–58) in all patients and 26 months (range, 4–58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive

  3. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shirvani, Shervin M.; Komaki, Ritsuko [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Heymach, John V.; Fossella, Frank V. [Department of Thoracic/Head and Neck Medical Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Chang, Joe Y., E-mail: jychang@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non-small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39-86). The median follow-up duration was 21 months (range, 4-58) in all patients and 26 months (range, 4-58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive intensity

  4. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  5. CT-guided procedures: evaluation of a phantom system to teach accurate needle placement

    International Nuclear Information System (INIS)

    Dimmick, S.; Jones, M.; Challen, J.; Iedema, J.; Wattuhewa, U.; Coucher, J.

    2007-01-01

    Aim: To evaluate the use of a phantom system to help teach the basic techniques of accurate CT-guided needle placement, thereby avoiding the risks associated with teaching on patients. Materials and Methods: Gelatine phantoms with five, 1.9 cm embedded spherical wooden targets were constructed. Four trainee operators performed 15 simulated biopsy procedures on the targets (series one) and repeated identical procedures 2 weeks later (series two). Statistical analysis of accuracy of needle placement and subject confidence were performed. Results: Significant sequential improvement in axial plane angular error was noted with the average error decreasing by 0.33 degrees after every five procedures performed (95% CI: -0.58 to -0.08, p = 0.01). Operator confidence indicated significant improvement both within each series and from series one to series two (95% CI: 0.08 to 1.17, p = 0.025 and 95% CI: 0.00 to 0.58, p = 0.05) respectively. However, variability in operator performance made statistically significant improvement in other variables unproven. Conclusion: Despite the study comprising a relatively small number of participants and procedures, it clearly demonstrated the effectiveness of teaching operators to perform CT-guided procedures using a phantom system. Needle placement accuracy significantly improved, with a reduction in axial angular error, and improved operator confidence without the risks associated with training on patients. Three of the operators in this study had never performed a CT-guided procedure previously, and their proficiency, after a relatively short but intense period of training, was impressive. The use of phantoms should be considered routinely for basic training of CT-guided needle placement

  6. Head and neck: normal variations and benign findings in FDG positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-04-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Role of AgNORs in thyroid lesions on fine needle aspiration cytology smears

    Directory of Open Access Journals (Sweden)

    Asotra Sarita

    2008-01-01

    Full Text Available Background: Fine needle aspiration has an important role in diagnosis of thyroid neoplasm. However, it is difficult to differentiate between follicular adenoma and follicular carcinoma by cytology alone. Recently, silver staining has been performed for nucleolar organizer regions (AgNORs to differentiate various tumors. Aims: The present study was undertaken to see if the AgNOR technique could distinguish between benign and malignant lesions, particularly, follicular neoplasm. Materials and Methods: One hundred forty cases of thyroid lesions were examined, which included colloid goiter (n = 36, multinodular goiter (n = 38, subacute thyroiditis (n = 6, Hashimoto′s thyroiditis (n = 17, lymphocytic thyroiditis (n = 3, follicular neoplasm (n = 18, Hurthle cell neoplasm (n = 3, papillary carcinoma (n = 16, and medullary carcinoma (n = 3. Diagnosis was confirmed by histopathology in 80 cases. The usual one-step silver colloidal reaction was performed at room temperature for 35 minutes and intranuclear dots of silver deposits were counted in 100 cells. Results: AgNOR counts of benign and malignant lesions were compared and were found to be statistically significant (P < 0.001. The mean AgNOR counts were higher in neoplastic lesions. Conclusions: AgNOR counting in fine needle aspiration smears is a simple, sensitive, and cost-effective method for differentiating benign from malignant thyroid follicular neoplasms.

  8. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    International Nuclear Information System (INIS)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.; Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G.

    2015-01-01

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy

  9. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Takaki, H. [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States); Laskhmanan, M. [Perfint Healthcare Inc (India); Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G., E-mail: srimaths@mskcc.org [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States)

    2015-10-15

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

  10. Prosthesis-guided implant restoration of an auricular defect using computed tomography and 3-dimensional photographic imaging technologies: a clinical report.

    Science.gov (United States)

    Wang, Shuming; Leng, Xu; Zheng, Yaqi; Zhang, Dapeng; Wu, Guofeng

    2015-02-01

    The concept of prosthesis-guided implantation has been widely accepted for intraoral implant placement, although clinicians do not fully appreciate its use for facial defect restoration. In this clinical report, multiple digital technologies were used to restore a facial defect with prosthesis-guided implantation. A simulation surgery was performed to remove the residual auricular tissue and to ensure the correct position of the mirrored contralateral ear model. The combined application of computed tomography and 3-dimensional photography preserved the position of the mirrored model and facilitated the definitive implant-retained auricular prosthesis. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Computed tomography of von Meyenburg complex simulating micro-abscesses

    International Nuclear Information System (INIS)

    Sada, P.N.; Ramakrishna, B.

    1994-01-01

    A case is presented of a bile duct hamartoma in a 44 year old man being evaluated for abdominal pain. The computed tomography (CT) findings suggested micro-abscesses in the liver and a CT guided tru-cut biopsy showed von Meyenburg complex. 9 refs., 3 figs

  12. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  13. Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration Cytology (SP-US-FNAC) Shortens Time for Diagnosis of Thyroid Nodules.

    Science.gov (United States)

    Gu, Wei Xiang; Tan, Chuen Seng; Ho, Thomas W T

    2014-06-01

    Ultrasound-guided fine-needle aspiration cytology (US-FNAC) of thyroid nodules is an important diagnostic procedure. In most hospitals, patients are referred to radiologists for US-FNAC, but this often results in a long waiting time before results are available. Surgeon-performed US-FNAC (SP-US-FNAC) during the initial patient consultation attempts to reduce the waiting time but it is not known whether this is as accurate as radiologist-performed US-FNAC (RP-US-FNAC). The aim of this study is to compare the clinical efficiency between SP-US-FNAC and RP-US-FNAC. A retrospective study was performed on patients from the Department of General Surgery, Tan Tock Seng Hospital (TTSH) who underwent an US-FNAC from August 2011 to May 2012. All cases of SP-US-FNAC were performed by a single surgeon. This study compared the rates of positive diagnoses achieved by SP-US-FNAC and RPUS- FNAC as well as the time interval to reach a cytological diagnosis by each group. A total of 40 cases of SP-US-FNAC and 72 cases of RP-US-FNAC were included in the study. SP-US-FNAC resulted in 28 (70%) positive diagnoses and 12 (30%) nondiagnoses while RP-US-FNAC resulted in 47 (65.3%) positive diagnoses and 25 (34.7%) non-diagnoses. These results were comparable (P=0.678). The median time taken to reach a cytological diagnosis was 1 working day for SP-US-FNAC and 29.5 working days for RP-US-FNAC resulting in a shorter interval to reaching a cytological diagnosis for SP-US-FNAC (P<0.001). In the workup of thyroid nodules, SP-US-FNAC is as accurate as RP-US-FNAC but significantly reduces the time taken to reach a cytological diagnosis. This leads to greater clinical efficiency in the management of patients with thyroid nodules, which in turn leads to other benefits such as decreased patient anxiety and increased patient satisfaction.

  14. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  15. A convenient tool for gas derivatization using fine-needle capillary mounting for protein crystals

    International Nuclear Information System (INIS)

    Mizuno, Nobuhiro; Makino, Masatomo; Kumasaka, Takashi

    2013-01-01

    A convenient gas-derivatization tool for protein crystals is presented in combination with a fine-needle capillary and a gas-pressure regulator. Gas derivatization of protein crystals is useful not only to analyse gas-binding proteins but also to solve the phase problem of X-ray crystallography by using noble gases. However, the gas pressurization tools for these experiments are often elaborate and need to release the gas before flash-cooling. To simplify this step, a procedure using a fine-needle capillary to mount and flash-cool protein crystals under the pressurization of gases has been developed. After the crystals are picked up with the capillary, the capillary is sealed with an adhesive and then connected directly to a gas regulator. The quality of the diffraction data using this method is comparable with that of data from conventional pressurization procedures. The preparation of xenon-derivatives of hen egg-white lysozyme using this method was a success. In the derivatives, two new xenon binding sites were found and one of their sites vanished by releasing the gas. This observation shows the availability of flash-cooling under gas pressurization. This procedure is simple and useful for preparing gas-derivative crystals

  16. Effect of a Biopsy Center on Adequacy Rates of Thyroid Nodule Fine-Needle Aspiration.

    Science.gov (United States)

    Leung, Vincent A; Kirpalani, Anish; Mnatzakanian, Gevork; Colak, Errol; Vlachou, Paraskevi A

    2017-08-01

    The purpose of this study was to investigate the effect of a biopsy center-a dedicated space with a dedicated ultrasound machine and technologist, staffed daily by a radiologist responsible for performing ultrasound-guided procedures only-on the rate of non-diagnostic or unsatisfactory thyroid fine-needle aspiration (FNA). Three radiologists performed FNA on 1200 nodules in 998 patients between September 2010 and November 2015. We compared rates of nondiagnostic or unsatisfactory FNA before and after implementation of a biopsy center in September 2014 as part of a quality improvement initiative. Before the establishment of our biopsy center, ultrasound-guided procedures were scheduled between diagnostic studies in the main ultrasound department and were performed by a radiologist responsible for both. Multivariate logistic regression analysis was performed to assess the effect of the biopsy center on the odds of obtaining an adequate sample. Rates of nondiagnostic or unsatisfactory FNA decreased significantly from 15.1% to 8.5% (p < 0.001) after implementation of the biopsy center. The odds of obtaining an adequate sample were higher in the biopsy center (odds ratio, 2.07; 95% CI, 1.43-3.01), even after adjusting for patient age, nodule size, the radiologist performing the procedure, and time over the study period. The implementation of a biopsy center was associated with significantly lower rates of nondiagnostic or unsatisfactory thyroid FNA, suggesting target rates of 10% or lower are achievable with quality improvement measures.

  17. Fine needle aspiration biopsy diagnosis of metastatic neoplasms of the breast. A three-case report

    Directory of Open Access Journals (Sweden)

    Raquel Garza-Guajardo

    2005-09-01

    Full Text Available Abstract Metastases to the breast are unusual lesions that make up approximately 2% of all malignant mammary neoplasms and may mimic both benign and malignant primary neoplasms from a clinical point of view, as well as in imaging studies. Arriving at a correct diagnosis is therefore essential in order to establish appropriate management. We present three cases of metastatic neoplasms diagnosed through fine needle aspiration biopsy and immunocytochemistry. The cytological diagnoses were: medulloblastoma in an 18-year-old woman, melanoma in a 26-year-old man, and an exceptional case of ovarian sarcoma originating from a granulosa cell tumor with metastases to both breasts. A metastatic disease should be considered in the differential diagnosis of a palpable mass in the breast, especially if there is a history of an extramammary malignant neoplasm. Fine needle aspiration biopsy is the method of choice for the management of these cases. Whenever possible the exam of the material obtained should be compared to the previous biopsy, which is usually enough to arrive at a correct diagnosis, thus preventing unnecessary surgical procedures.

  18. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  19. Development of an ultrasound-guided technique for retrobulbar nerve block in dromedary camels: a cadaveric study.

    Science.gov (United States)

    Badawy, Adel M; Eshra, Eman A

    2018-03-01

    Description of an ultrasound (US)-guided technique for retrobulbar nerve blockade in dromedary (Camelus dromedarius) cadavers. Prospective experimental cadaveric study that was carried out in three phases: phase I: anatomical dissection and development of US-guided technique; phase II: methylene blue (MB) injection; phase III: contrast medium (CM), US-guided injections with computed tomography (CT) control. A total of 36 orbits from 18 heads were obtained from 18 dromedary cadavers. Phase I: anatomical dissections were carried out bilaterally, using two heads to determine needle site placement. Phase II: a US-guided, lateral, in-plane approach using one of three volumes of MB (3, 6, or 9 mL) was evaluated in six heads (four orbits per volume tested) to establish the ideal injection volume. Injections of MB that strongly stained all retrobulbar nerves were considered successful, whereas insufficient MB volumes resulted in weak or no nerve staining. Phase III: US-guided retrobulbar injection with CM was carried out using 20 orbits. Computed tomography was performed after each injection trial to determine the accuracy of needle placement and CM dispersal. An injection was judged to be successful when the CT images revealed that the needle was located within the retractor bulbi muscle cone and the CM reached the target nerves at the orbitorotundum and the optic foramina. Only injection of 9 mL of MB stained the target nerves sufficiently, whereas there was no or only weak staining with 3 and 6 mL, respectively. Therefore, 9 mL of CM was used for the US-guided injections in phase III. Subsequent CT scans revealed satisfying CM distribution within the ocular muscle cone in 18 of 20 cases (90% success rate). US-guided retrobulbar injection in dromedary cadavers is feasible. Further research is required to assess its practicality and usefulness in vivo. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and

  20. 3D artificial bones for bone repair prepared by computed tomography-guided fused deposition modeling for bone repair.

    Science.gov (United States)

    Xu, Ning; Ye, Xiaojian; Wei, Daixu; Zhong, Jian; Chen, Yuyun; Xu, Guohua; He, Dannong

    2014-09-10

    The medical community has expressed significant interest in the development of new types of artificial bones that mimic natural bones. In this study, computed tomography (CT)-guided fused deposition modeling (FDM) was employed to fabricate polycaprolactone (PCL)/hydroxyapatite (HA) and PCL 3D artificial bones to mimic natural goat femurs. The in vitro mechanical properties, in vitro cell biocompatibility, and in vivo performance of the artificial bones in a long load-bearing goat femur bone segmental defect model were studied. All of the results indicate that CT-guided FDM is a simple, convenient, relatively low-cost method that is suitable for fabricating natural bonelike artificial bones. Moreover, PCL/HA 3D artificial bones prepared by CT-guided FDM have more close mechanics to natural bone, good in vitro cell biocompatibility, biodegradation ability, and appropriate in vivo new bone formation ability. Therefore, PCL/HA 3D artificial bones could be potentially be of use in the treatment of patients with clinical bone defects.

  1. Image-guided fine needle cytology with aspiration versus non-aspiration in retroperitoneal masses: is aspiration necessary?

    Science.gov (United States)

    Misra, Rajiv Kumar; Mitra, Shaila; Jain, Rishav Kumar; Vahikar, Shilpa; Bundela, Archana; Misra, Purak

    2015-03-01

    Although using fine needle cytology with aspiration (FNC-A) for establishing diagnoses in the retroperitoneal region has shown promise, there is scant literature supporting a role of non-aspiration cytology (FNC-NA) for this region. We assessed the accuracy and reliability of FNC-A and FNC-NA as tools for preoperative diagnosis of retroperitoneal masses and compared the results of both techniques with each other and with histopathology. Fifty-seven patients with retroperitoneal masses were subjected to FNC-A and FNC-NA. Smears were stained with May-Grunwald Giemsa and hematoxylin and eosin stain. An individual slide was objectively analysed using a point scoring system to enable comparison between FNC-A and FNC-NA. By FNC-A, 91.7% accuracy was obtained in cases of retroperitoneal lymph node lesions followed by renal masses (83.3%). The diagnostic accuracy of other sites by FNC-A varied from 75.0%-81.9%. By FNC-NA, 93.4% diagnostically accurate results were obtained in the kidney, followed by 75.0% in adrenal masses. The diagnostic accuracy of other sites by FNC-NA varied from 66.7%-72.8%. Although both techniques have their own advantages and disadvantages, FNC-NA may be a more efficient adjuvant method of sampling in retroperitoneal lesions.

  2. Cross-sectional anatomy for computed tomography

    International Nuclear Information System (INIS)

    Farkas, M.L.

    1988-01-01

    This self-study guide recognizes that evaluation and interpretation of CT-images demands a firm understanding of both cross-sectional anatomy and the principles of computed tomography. The objectives of this book are: to discuss the basic principles of CT, to stress the importance of cross-sectional anatomy to CT through study of selected cardinal transverse sections of head, neck, and trunk, to explain orientation and interpretation of CT-images with the aid of corresponding cross-sectional preparations

  3. Automated tru-cut imaging-guided core needle biopsy of canine ...

    African Journals Online (AJOL)

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single ...

  4. Solitary thyroid metastasis from colon cancer: fine-needle aspiration cytology and molecular biology approach.

    Science.gov (United States)

    Onorati, M; Uboldi, P; Bianchi, C L; Nicola, M; Corradini, G M; Veronese, S; Fascì, A I; Di Nuovo, F

    2015-01-01

    Thyroid gland is one of the most vascularized organs of the body, nevertheless clinical and surgical series report an incidence of secondary malignancies in this gland of only 3%. Colorectal carcinoma metastatic to the thyroid gland is not as uncommon as previously believed, infact the number of cases seems to be increased in recent years due to the more frequent use of fine-needle aspiration cytology (FNAC) guided by ultrasonography. Although kidney, breast and lung metastases to the thyroid are frequent, metastasis from colon cancer is clinically rare with 52 cases reported in the literature in the last 5 decades and three cases described as solitary thyroid metastasis from the colon cancer without any other visceral metastases. To the best of our knowledge, we report the fourth case of solitary, asymptomatic thyroid metastasis from colon cancer without involvement of other organs. We discuss the importance of FNAC to detect metastatazing process as a compulsory step of the diagnostic and therapeutic management algorithm, combined with a molecular biology approach. A review of the last 5 decades literature, to update the number of cases described to date, is also included.

  5. Celiac plexus block: an anatomical study and simulation using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Gabriela Augusta Mateus; Lopes, Paulo Tadeu Campos; Santos, Ana Maria Pujol Vieira dos, E-mail: pclopes@ulbra.br [Universidade Luterana do Brasil (Ulbra), Canoas, RS (Brazil); Pozzobon, Adriane [Centro Universitario Univates, Lajeado, RS (Brazil); Duarte, Rodrigo Dias; Cima, Alexandre da Silveira; Massignan, Angela [Fundacao Serdil/Saint Pastous, Porto Alegre, RS (Brazil)

    2014-09-15

    Objective: to analyze anatomical variations associated with celiac plexus complex by means of computed tomography simulation, assessing the risk for organ injury as the transcrural technique is utilized. Materials and Methods: one hundred eight transaxial computed tomography images of abdomen were analyzed. The aortic-vertebral, celiac trunk (CeT)-vertebral, CeT-aortic and celiac-aortic-vertebral topographical relationships were recorded. Two needle insertion pathways were drawn on each of the images, at right and left, 9 cm and 4.5 cm away from the midline. Transfixed vital organs and gender-related associations were recorded. Results: aortic-vertebral - 45.37% at left and 54.62% in the middle; CeT-vertebral - T12, 36.11%; T12-L1, 32.4%; L1, 27.77%; T11-T12, 2.77%; CeT-aortic - 53.7% at left and 46.3% in the middle; celiac-aortic-vertebral - L-l, 22.22%; M-m, 23.15%; L-m, 31.48%; M-l, 23.15%. Neither correspondence on the right side nor significant gender-related associations were observed. Conclusion: considering the wide range of abdominal anatomical variations and the characteristics of needle insertion pathways, celiac plexus block should not be standardized. Imaging should be performed prior to the procedure in order to reduce the risks for injuries or for negative outcomes to patients. Gender-related anatomical variations involved in celiac plexus block should be more deeply investigated, since few studies have addressed the subject. (author)

  6. Celiac plexus block: an anatomical study and simulation using computed tomography

    International Nuclear Information System (INIS)

    Pereira, Gabriela Augusta Mateus; Lopes, Paulo Tadeu Campos; Santos, Ana Maria Pujol Vieira dos; Pozzobon, Adriane; Duarte, Rodrigo Dias; Cima, Alexandre da Silveira; Massignan, Angela

    2014-01-01

    Objective: to analyze anatomical variations associated with celiac plexus complex by means of computed tomography simulation, assessing the risk for organ injury as the transcrural technique is utilized. Materials and Methods: one hundred eight transaxial computed tomography images of abdomen were analyzed. The aortic-vertebral, celiac trunk (CeT)-vertebral, CeT-aortic and celiac-aortic-vertebral topographical relationships were recorded. Two needle insertion pathways were drawn on each of the images, at right and left, 9 cm and 4.5 cm away from the midline. Transfixed vital organs and gender-related associations were recorded. Results: aortic-vertebral - 45.37% at left and 54.62% in the middle; CeT-vertebral - T12, 36.11%; T12-L1, 32.4%; L1, 27.77%; T11-T12, 2.77%; CeT-aortic - 53.7% at left and 46.3% in the middle; celiac-aortic-vertebral - L-l, 22.22%; M-m, 23.15%; L-m, 31.48%; M-l, 23.15%. Neither correspondence on the right side nor significant gender-related associations were observed. Conclusion: considering the wide range of abdominal anatomical variations and the characteristics of needle insertion pathways, celiac plexus block should not be standardized. Imaging should be performed prior to the procedure in order to reduce the risks for injuries or for negative outcomes to patients. Gender-related anatomical variations involved in celiac plexus block should be more deeply investigated, since few studies have addressed the subject. (author)

  7. Needle stick injuries during fine needle aspiration procedure: Frequency, causes and knowledge, attitude and practices of cytopathologists

    Directory of Open Access Journals (Sweden)

    Neeta Kumar

    2011-01-01

    Full Text Available Background: There is no study available on the frequency, predisposing factors and outcome of needle stick injury (NSI in cytopathologists who perform fine needle aspiration (FNA. Aim: To know the frequency, circumstances and sequlae of NSI sustained by cytopathologists, assess their knowledge about risks of NSI and attitudes and practices towards use of standard precautions and post-injury wound care. Materials and Methods: Study design: cross sectional. Setting: Tertiary care teaching and non-teaching hospitals and private laboratories. Data collection method: Knowledge, attitude and practices survey using a questionnaire. Results: Majority (90.5% of the respondents have had NSI in their total career. In the previous year, more than half (71.4% had at least one NSI (mean 3.2. NSI was the most common in index finger of non-dominant hand (59.6% and occurred during step two of FNA procedure when the needle was being manipulated within the lump. The major predisposing factors were uncooperative patients (88.9%, small children (54%, deep masses (36.5%, hot humid climate (88.9%, heavy workload (76.2% and poor administrative arrangement (54%. The adherence to standard precautions was not optimal (74.6%. None of them reported NSI to the authorities, nor investigated source patient or themselves. 82.5% of the respondents were not aware of any formal exposure reporting system in their hospital. Conclusion: Cytopathologists frequently experience NSI while performing FNA. Frequency of injury is also related to patient characteristics and work site factors. Education and motivation for adhering to standard precautions and post-exposure prophylaxis are often lacking.

  8. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  9. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  10. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  11. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  12. CT-guided core biopsy of malignant lung lesions: how many needle passes are needed?

    International Nuclear Information System (INIS)

    Lim, Chaehun; Han, Dae Hee; Lee, Kyo Young; Kim, Young Kyoon; Ko, Jeong Min

    2013-01-01

    The study aims to determine the number of needle pass in the CT-guided core needle biopsy (CNB) in making a diagnosis of pulmonary malignancy. A total of 434 CNB records were retrospectively reviewed. The specimen obtained from each needle pass was put in a formalin container and then labelled for separate histopathological reporting. The patients were divided into five groups according to the total number of needle passes (n=1, n=2, n=3, n=4 and n≥5). In each of the groups 2–4, it was analysed how many needle passes are required before a plateau in diagnostic yield is achieved. CNB produced 283 true-positive and 23 false-negative diagnosis of malignancy. Cumulative sensitivity significantly (P<0.05) increased between the first and second as well as the second and the third (if done) needle passes, but not between the third and fourth ones. Three coaxial needle passes might be optimal in the diagnosis of lung malignancy.

  13. Ultrasonography-guided fine-needle aspiration biopsy for thyroid nodules: effective technique and a peculiar smear method

    International Nuclear Information System (INIS)

    Park, Kyeong Rok; Rho, Myung Ho; Kim, Dong Wook; Koo, Yong Woon; Lee, Kyeong Hee; Kang, Tae Woo

    2006-01-01

    We wanted to evaluate the effective methods that are appropriate for an endemic area of thyroid disease and to compare the differences of cytologic diagnostic rates with and without using a peculiar smear technique. We analyzed the incidence rate of insufficient results, complications and the total procedure times of 1,126 thyroid nodules in 776 patients who underwent US-FNAB (ultrasonography-guided fine-needle aspiration biopsy) from January to December 2005. We compared the diagnostic rate between the two groups; the groups' tests were performed with a peculiar smear technique (Group A, n 313) or with a ventional smear technique (Group B, n = 250). According to the size of the thyroid nodule, the incidence rate of an insufficient result on US-FNAB and the mean total procedure time for 1126 thyroid nodules in 776 patients were measured as 16.9% (52/308) and 208 seconds for nodules under 0.5 cm, 9.8% (30/306) and 160 seconds for nodules between 0.5 cm-10 cm, and 6.0% (30/504) and 134 seconds for nodules over 1.0 cm. These 776 patients showed no significant complication, except for mild pain. In Group A, the incidence rate of an insufficient result was calculated as 15.1% (14/93) for the group with nodules under 0.5 cm, 5.3% (5/95) for the group with nodules between 0.5 cm-1.0 cm, 4.8% (6/125) for the group with nodules over 1.0 cm, and 8.0% (25/313) for the total A Group. In Group B, the incidence rate of an insufficient result was measured as 33.3% (15/45) for the group with nodules under 0.5 cm, 28.1% (25/89) for the group with nodules between 0.5 cm-1.0 cm, 21.4% (24/112) for the group with nodules over 1.0 cm, and 25.7% (63/245) for the total B group. There was a statistically significant correlation between the rate of an insufficient result and the peculiar smear technique or the size of the thyroid nodule. We consider that US-FNAB is very simple, safe and accurate diagnostic method for thyroid nodules, and US-FNAB with a peculiar smear technique is able to

  14. X-Ray Computed Tomography of Tranquility Base Moon Rock

    Science.gov (United States)

    Jones, Justin S.; Garvin, Jim; Viens, Mike; Kent, Ryan; Munoz, Bruno

    2016-01-01

    X-ray Computed Tomography (CT) was used for the first time on the Apollo 11 Lunar Sample number 10057.30, which had been previously maintained by the White House, then transferred back to NASA under the care of Goddard Space Flight Center. Results from this analysis show detailed images of the internal structure of the moon rock, including vesicles (pores), crystal needles, and crystal bundles. These crystals, possibly the common mineral ilmenite, are found in abundance and with random orientation. Future work, in particular a greater understanding of these crystals and their formation, may lead to a more in-depth understanding of the lunar surface evolution and mineral content.

  15. Non-real-time computed tomography-guided percutaneous ethanol injection therapy for heapocellular carcinoma undetectable by ultrasonography

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    1998-01-01

    The purpose of this study was to evaluate the feasibility of non-real-time CT-guided percutaneous ethanol injection therapy (PEIT) for hepatocellular carcinoma (HCC, 37 lesions) untreatable by ultrasonography-guided (US)-PEIT. The HCC lesion was localized on the lipiodol CT image with a graduated grid system. We advanced a 21 G or 22 G needle in a stepwise fashion with intermittent localization scans using a tandem method to position the tip of the needle in the lesion. Ethanol containing contrast medium was injected with monitoring scans obtained after incremental volumes of injection, until perfusion of the lesion was judged to be complete. A total of 44 CT-PEIT procedures were performed. The average number of needle passes from the skin to the liver in each CT-PEIT procedure was 2.3, the average amount of ethanol injected was 14.4 ml, and the average time required was 49.3 minutes. Complete perfusion of the lesion by ethanol on monitoring CT images was achieved in all lesions with only a single or double CT-PEIT procedure without severe complication. Local recurrence was detected only in 5 lesions. At present, it is more time-consuming to perform CT-PEIT than US-PEIT because conventional CT guidance is not real-time imaging. However, it is expected that this limitation of CT-PEIT will be overcome in the near future with the introduction of CT fluoroscopy. In conclusion, CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC undetectable by US. (author)

  16. Incisional endometriosis: diagnosed by fine needle aspiration cytology.

    Science.gov (United States)

    Veda, P; Srinivasaiah, M

    2010-07-01

    Incisional endometriosis (IE) is a rare entity reported in 0.03-1.08% of women following obstetric or gynecologic surgeries. Most cases reported in literature have appeared after cesarean sections and were often clinically mistaken for hernia, abscess, suture granuloma or lipoma. We hereby report a case of IE following a second trimester hysterotomy, which was diagnosed by fine needle aspiration cytology (FNAC). Our patient was 26 years old, presenting with a mass over anterior abdominal wall, associated with incapacitating pain during each menstrual cycle. FNAC showed epithelial cells, stromal cells and hemosiderin laden macrophages. Based on the typical history, clinical and cytological features, the diagnosis of IE was established. Wide surgical excision was done and the resulting rectus sheath defect was repaired. Patient was followed for 6 months during which time she was symptom free. This article also reviews the spectrum of cytological features and the rare possibility of malignant transformation that can occur in IE.

  17. Comparative cost-effectiveness of fine needle aspiration biopsy versus image-guided biopsy, and open surgical biopsy in the evaluation of breast cancer in the era of Affordable Care Act: a changing landscape.

    Science.gov (United States)

    Masood, Shahla; Rosa, Marilin; Kraemer, Dale F; Smotherman, Carmen; Mohammadi, Amir

    2015-08-01

    Proven as a time challenged and cost-effective sampling procedure, the use of FNAB has still remained controversial among the scientific community. Currently, other minimally invasive sampling procedures such as ultrasound guided fine needle aspiration biopsy (US-FNAB) and image guided core needle biopsy (IG-CNB) have become the preferred sampling procedures for evaluation of breast lesions. However, changes in the medical economy and the current growing emphasis on cost containment in the era of the Affordable Care Act make it necessary to stimulate a renewed interest in the use of FNAB as the initial diagnostic sampling procedure. This study was designed to define the changing trend in the practice of tissue sampling during the last several years, and to assess the comparative effectiveness and appropriateness of the procedure of choice for breast cancer diagnosis. After Institutional Review Board (IRB) approval, the computer database of the Pathology Department, University of Florida, College of Medicine-Jacksonville at UF Health was retrospectively searched to identify all breast biopsy pathology reports issued during the period of January 2004 to December 2011. The inclusion criteria were all women that underwent any of the following biopsy types: FNAB, US-FNAB, IG-CNB, and surgical biopsy (SB). Diagnostic procedures were identified using current procedural terminology (CPT) codes recorded on claims from the UF Health Jacksonville patient accounting application files. The data obtained was used to determine which technique has the best cost-effectiveness in the diagnosis of breast cancer. The outcome variable for this project was a positive breast cancer diagnosis resulting from these methodologies. The predictor variable was the biopsy type used for sampling. The rate of cancer detection for each procedure was also determined. Among the four groups of procedures compared, the lower cost was attributed to FNAB, followed by US-FNAB, and SB. IG-CNB was the most

  18. Fine-needle aspiration cytology as a diagnostic modality for cysticercosis: A clinicocytological study of 137 cases

    Directory of Open Access Journals (Sweden)

    Pooja Kala

    2014-01-01

    Conclusion: Fine-needle aspiration cytology in cysticercosis is a low-cost outpatient procedure. The cytological diagnosis is quite straightforward in cases where the actual parasite structures are identified in the smears. In other cases, a cytological diagnosis of suspicious of cysticercosis can be given if the cytological findings suggest the same.

  19. Endoscopic Ultrasound Fine-Needle Aspiration Characteristics of Primary Adenocarcinoma versus Other Malignant Neoplasms of The Pancreas

    Directory of Open Access Journals (Sweden)

    Veronika Gagovic

    2012-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA is often used to assist in the evaluation of pancreatic lesions and may help to diagnose benign versus malignant neoplasms. However, there is a paucity of literature regarding comparative EUS characteristics of various malignant pancreatic neoplasms (primary and metastatic.

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  2. WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de

  3. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    This article is part of a combined publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling in gastroenterology, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided trucut biopsy (EU...

  4. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  5. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  6. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  7. Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions

    International Nuclear Information System (INIS)

    Clevert, D.A.; Helck, A.; Paprottka, P.M.; Trumm, C.; Reiser, M.F.; Zengel, P.

    2012-01-01

    Abdominal ultrasound is often the first-line imaging modality for assessing focal liver lesions. Due to various new ultrasound techniques, such as image fusion, global positioning system (GPS) tracking and needle tracking guided biopsy, abdominal ultrasound now has great potential regarding detection, characterization and treatment of focal liver lesions. Furthermore, these new techniques will help to improve the clinical management of patients before and during interventional procedures. This article presents the principle and clinical impact of recently developed techniques in the field of ultrasound, e.g. image fusion, GPS tracking and needle tracking guided biopsy and discusses the results based on a feasibility study on 20 patients with focal hepatic lesions. (orig.) [de

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  10. The research of knitting needle status monitoring setup

    Science.gov (United States)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  11. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    Science.gov (United States)

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  12. Fine needle biopsy of thyroid nodules: correlations between cytology and gistology, technical aspects

    Directory of Open Access Journals (Sweden)

    Yu Fedotov

    2009-12-01

    Full Text Available The results of comparative preoperative cytological and postoperative histological investigation of 3714 patients with thyroid nodules are presented. The causes of discrepancies are discussed and measures of their diminution are proposed. Great value of fine needle biopsy to differ thyroid nodules but follicular neoplasia into benign and malignant are determined. Its sensitivity in our clinics is 98.7% and specificity – 100%. Necessity of the of the second FNA if the first one is non informative is established.

  13. The factor analysis of the incidence of pneumothorax after CT-guided transthoracic needle aspiration biopsy

    International Nuclear Information System (INIS)

    Zhong Tao; Yu Hongguang; Wang Yong; Yang Sifu; Wang Xiaoxuan

    2007-01-01

    Objective: To analyze the impact of multiple factors on the incidence of pneumothorax associated with CT-guided transthoracic needle aspiration biopsy. Methods: The sign of pneumothorax after 162 cases (lesion diameter from 1 cm to 6 cm) CT-guided transthoracic needle aspiration biopsy was observed and its relationship with multivariate factors were analyzed by multivariate logistic regression model. Results: Thirty-two cases presented pneumothorax accounting for 19. 8%. Single variate analysis showed that the sign of pneumothorax related to intercurrent COPD, distance from lesion and chest wall, needle dwelling time and lesion diameter. 67 patients of intercurrent COPD with postoperative pneumothorax occurred in 22 cases (32.8%); With respect to those having lesions close to the chest wall (48 cases), and the cases with the distance between the chest wall and lesions less than 2 cm (55 cases) and greater than 2 cm (59 cases), the postoperative pneumothorax occurred in 0, 14 (25.5%), 18 (30.5%) cases respectively; For those patients with needle in the chest residence time of less than 10 minutes (82 cases), 10-20 minutes (51 cases), more than 20 minutes (28 cases) after the occurrence of pneumothorax were 8 (9.6%), 10(19.6%), 14 (50%) cases respectively; In contrast, those with lesion diameter less than 2 cm (65 cases), 2-4 cm(52 cases), more than 4cm(45 cases) were 19 (29.2%), 8 (15.4%) and 5 (11.1% ) respectively. The multivariate logistic regression analysis showed that the prior three factor's were risk factors of pneumothorax (OR=4.652, 4.030, 2.855 respectively). Conclusions: To avoid the pneumothorax, caution must be taken with respect to CT-guided transthoracic needle aspiration biopsy, patients with intercurrent COPD, long distance between lesion and chest wall, and smaller lesion diameter. For operation the needle dwell time within thorax should be minimized. (authors)

  14. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  15. Accuracy of Cytology for Diagnosis of Lipomatous Tumors: Comparison with Magnetic Resonance and Computed Tomography Findings in 175 cases

    International Nuclear Information System (INIS)

    Einarsdottir, H.; Skoog, L.; Soederlund, V.; Bauer, H.C.F.

    2004-01-01

    Purpose: To assess the value of fine-needle aspiration cytology in the diagnostic work-up of lipomatous tumors of the extremities and trunk, and to identify specific radiological features that could aid in the preoperative evaluation. Material and Methods: 175 patients with subfascial lipomatous tumors who had undergone preoperative magnetic resonance imaging or computed tomography and fine-needle aspiration cytology were studied. The percentage of fat within the lesion was visually graded from the images as: none, 1-75%, 75-95%, or 95-100%. The histological and cytological diagnoses were compared and in discordant cases the radiological images were re-reviewed. Results: There was cytological and histological concordance in 96% of lipomas and in 85% of atypical lipomatous tumors (ALT) and liposarcomas. Most discordant cases exhibited 1-75% fat. Radiological review suggested that cytological sampling problems due to tumor heterogeneity were the main cause of diagnostic difficulties. The majority of tumors with less than 75% fat were liposarcomas, and in no liposarcoma was the fat content higher than 75%. Both ALT and lipoma were found in the 95-100% group. Conclusion: Cytology can be highly accurate in the diagnosis of lipomatous tumors, including ALT; however, critical comparison with the radiological findings increases diagnostic security. In tumors with fat content visually assessed as less than 75% of the tumor volume, liposarcoma is the most likely diagnosis and a cytological diagnosis of ALT or lipoma should be questioned. In lesions with 75-95% fat, liposarcoma is unlikely, but FNAC is still indicated for safety. In lesions with 95-100% fat, FNAC is only indicated if the differentiation between lipoma and ALT influences the treatment strategy

  16. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy

    Science.gov (United States)

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  17. Just-in-time tomography (JiTT): a new concept for image-guided radiation therapy

    International Nuclear Information System (INIS)

    Pang, G; Rowlands, J A

    2005-01-01

    Soft-tissue target motion is one of the main concerns in high-precision radiation therapy. Cone beam computed tomography (CBCT) has been developed recently to image soft-tissue targets in the treatment room and guide the radiation therapy treatment. However, due to its relatively long image acquisition time the CBCT approach cannot provide images of the target at the instant of the treatment and thus it is not adequate for imaging targets with intrafraction motion. In this note, a new approach for image-guided radiation therapy-just-in-time tomography (JiTT)-is proposed. Differing from CBCT, JiTT takes much less time to generate the needed tomographical, beam's-eye-view images of the treatment target at the right moment to guide the radiation therapy treatment. (note)

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  19. Preliminary Results of Emergency Computed Tomography-Guided Ventricular Drain Placement-Precision for the Most Difficult Cases.

    Science.gov (United States)

    Nowacki, Andreas; Wagner, Franca; Söll, Nicole; Hakim, Arsany; Beck, Jürgen; Raabe, Andreas; Z'Graggen, Werner J

    2018-04-05

    External ventricular drainage (EVD) catheter placement is one of the most commonly performed neurosurgical procedures. The study's objective was to compare a computed tomography (CT) bolt scan-guided approach for the placement of EVDs with conventional landmark-based insertion. In this retrospective case-control study, we analyzed patients undergoing bolt-kit EVD catheter placement, either CT-guided or landmark-based, between 2013 and 2016. The CT bolt scan-guided approach was based on a dose-reduced CT scan after bolt fixation with immediate image reconstruction along the axis of the bolt to evaluate the putative insertion axis. If needed, angulation of the bolt was corrected and the procedure repeated before the catheter was inserted. Primary endpoint was the accuracy of insertion. Secondary endpoints were the overall number of attempts, duration of intervention, complication rates, and cumulative radiation dose. In total, 34 patients were included in the final analysis. In the group undergoing CT-guided placement, the average ventricle width was significantly smaller (P = 0.04) and average midline shift significantly more pronounced (P = 0.01). CT-guided placement resulted in correct positioning of the catheter in the ipsilateral frontal horn in all 100% of the cases compared with landmark-guided insertion (63%; P = 0.01). Application of the CT-guided approach increased the number of total CT scans (3.6 ± 1.9) and the overall radiation dose (3.34 ± 1.61 mSv) compared with the freehand insertion group (1.84 ± 2.0 mSv and 1.55 ± 1.66 mSv). No differences were found for the other secondary outcome parameters. CT-guided bolt-kit EVD catheter placement is feasible and accurate in the most difficult cases. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  1. Improving CT-guided transthoracic biopsy of mediastinal lesions by diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; TyngI, Chiang Cheng; Bitencourt, Almir Galvao Vieira; Gross, Jefferson Luiz; Zurstrassen, Charles Edouard, E-mail: marcosduarte500@gmail.com [AC Camargo Cancer Center, Sao Paulo, SP (Brazil); Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), RS (Brazil). Dept. de Radiologia; Benveniste, Marcelo Felipe Kuperman; Odisio, Bruno Calazans [University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), Petropolis, RJ (Brazil)

    2014-11-15

    Objectives: to evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions. Methods: eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion. Results: in all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6–1.1]610{sup -3} mm{sup 2}/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymoma s. Conclusion: functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques. (author)

  2. Risk factors of pneumothorax in percutaneous fine needle aspiration biopsy of the lung

    International Nuclear Information System (INIS)

    Kim, Sang Jin; Park, Kwang Joo; Shin, Hyung Cheol; Kwon, Ryang; Jo, Byung June; Oh, Sei Jung; Ahn, Chang Su; Kim, Hyung Jung

    1997-01-01

    Percutaneous fine needle aspiration biopsy is known to be a useful diagnostic method for the diagnosis of various pulmonary diseases. Its diagnostic yield is high, and it is safe, but complications such as pneumothorax can occasionally occur. We reviewed the complications arising after needle aspiration biopsy and analyzed the risk factors of pneumothorax. The medical records and radiographic studies of 157 patients with various pulmonary diseases who underwent needle aspiration biopsy of the lung between 1990 and 1996 were retrospectively reviewed. The clinical features, treatment, and courses of complications were reviewed, and risk factors of pneumothorax such as depth and size of lesion, diameter of needle, number of punctures, and obstructive pulmonary abnormalities were analyzed. Complications occurred in 40 of 157cases(25.5%), namely pneumothorax in 26(16.6%), hemoptysis in 11(7%), hemothorax in two(1.3%), and recurrence of malignancy at the site of aspiration in one(0.6%). When the patients were divided into three groups according to depth of lesion, there were significant difference in the incidence of pneumothorax;the results were as follows:less than 2cm, 12.9%;between 2 and 4cm, 24.1%;and larger than 4cm, 57.1%(p<0.05). In pulmonary function testing, FVC(Forced Vital Capacity) of patients with pneumothorax was less than that of patients without(2.6±0.9L vs 3.1±0.8L, p<0.05), but FEV1(Forced Expiratory Volume in 1 second), FEV1%(percentage of predicted FEV1), FEV1/FVC, and FVC% (percentage of predicted FVC) were not different between the two groups. The incidence of pneumothorax in patients with pleura-at-tached lesion (9%) was lower than that of those with non-attached lesion(26%, p=3D0.01). The age of patients, size of lesion, diameter of the needle, guidance methods and number of aspirations showed no significant relationship with pneumothorax. In needle aspiration biopsy of the lung, depth of lesion and passage of a needle through aerated lung are

  3. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  4. Fine needle aspiration cytology and cell block in the diagnosis of seminoma testis

    Directory of Open Access Journals (Sweden)

    Abhishant Pandey

    2011-01-01

    Full Text Available Testicular neoplasms which show a wide variety of morphologic types, comprise a small proportion of malignancies. Early identification and treatment is essential for achieving long term survival. The cytologic findings in fine needle aspiration smears from left testicular swelling of a 49 year old male suggestive of a germ cell tumor was complimented by cell block preparation as seminoma. This was confirmed by histopathologic studies. We are presenting this case to emphasize that cell block can be used for diagnosis of testicular tumors.

  5. Comparison of the accuracy of cone beam computed tomography and medical computed tomography: implications for clinical diagnostics with guided surgery.

    Science.gov (United States)

    Abboud, Marcus; Calvo-Guirado, Jose Luis; Orentlicher, Gary; Wahl, Gerhard

    2013-01-01

    This study compared the accuracy of cone beam computed tomography (CBCT) and medical-grade CT in the context of evaluating the diagnostic value and accuracy of fiducial marker localization for reference marker-based guided surgery systems. Cadaver mandibles with attached radiopaque gutta-percha markers, as well as glass balls and composite cylinders of known dimensions, were measured manually with a highly accurate digital caliper. The objects were then scanned using a medical-grade CT scanner (Philips Brilliance 64) and five different CBCT scanners (Sirona Galileos, Morita 3D Accuitomo 80, Vatech PaX-Reve3D, 3M Imtech Iluma, and Planmeca ProMax 3D). The data were then imported into commercially available software, and measurements were made of the scanned markers and objects. CT and CBCT measurements were compared to each other and to the caliper measurements. The difference between the CBCT measurements and the caliper measurements was larger than the difference between the CT measurements and the caliper measurements. Measurements of the cadaver mandible and the geometric reference markers were highly accurate with CT. The average absolute errors of the human mandible measurements were 0.03 mm for CT and 0.23 mm for CBCT. The measurement errors of the geometric objects based on CT ranged between 0.00 and 0.12 mm, compared to an error range between 0.00 and 2.17 mm with the CBCT scanners. CT provided the most accurate images in this study, closely followed by one CBCT of the five tested. Although there were differences in the distance measurements of the hard tissue of the human mandible between CT and CBCT, these differences may not be of clinical significance for most diagnostic purposes. The fiducial marker localization error caused by some CBCT scanners may be a problem for guided surgery systems.

  6. Image-Guided Radiotherapy for Liver Cancer Using Respiratory-Correlated Computed Tomography and Cone-Beam Computed Tomography

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Sweeney, Reinhart A.; Wilbert, Juergen; Krieger, Thomas; Richter, Anne; Baier, Kurt; Mueller, Gerd; Sauer, Otto; Flentje, Michael

    2008-01-01

    Purpose: To evaluate a novel four-dimensional (4D) image-guided radiotherapy (IGRT) technique in stereotactic body RT for liver tumors. Methods and Materials: For 11 patients with 13 intrahepatic tumors, a respiratory-correlated 4D computed tomography (CT) scan was acquired at treatment planning. The target was defined using CT series reconstructed at end-inhalation and end-exhalation. The liver was delineated on these two CT series and served as a reference for image guidance. A cone-beam CT scan was acquired after patient positioning; the blurred diaphragm dome was interpreted as a probability density function showing the motion range of the liver. Manual contour matching of the liver structures from the planning 4D CT scan with the cone-beam CT scan was performed. Inter- and intrafractional uncertainties of target position and motion range were evaluated, and interobserver variability of the 4D-IGRT technique was tested. Results: The workflow of 4D-IGRT was successfully practiced in all patients. The absolute error in the liver position and error in relation to the bony anatomy was 8 ± 4 mm and 5 ± 2 mm (three-dimensional vector), respectively. Margins of 4-6 mm were calculated for compensation of the intrafractional drifts of the liver. The motion range of the diaphragm dome was reproducible within 5 mm for 11 of 13 lesions, and the interobserver variability of the 4D-IGRT technique was small (standard deviation, 1.5 mm). In 4 patients, the position of the intrahepatic lesion was directly verified using a mobile in-room CT scanner after application of intravenous contrast. Conclusion: The results of our study have shown that 4D image guidance using liver contour matching between respiratory-correlated CT and cone-beam CT scans increased the accuracy compared with stereotactic positioning and compared with IGRT without consideration of breathing motion

  7. A serious game for learning ultrasound-guided needle placement skills.

    Science.gov (United States)

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  8. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  9. Computed tomography-guided percutaneous trephine removal of the nidus in osteoid osteoma patients: experience of a single center in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Petrilli, Marcelo; Senerchia, Andreza Almeida; Petrilli, Antonio Sergio; Lederman, Henrique Manoel; Garcia Filho, Reynaldo Jesus, E-mail: andrezasenerchia@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Instituto de Oncologia Pediatrica

    2015-07-15

    Objective: to report the results of computed tomography (CT)-guided percutaneous resection of the nidus in 18 cases of osteoid osteoma. Materials and methods: the medical records of 18 cases of osteoid osteoma in children, adolescents and young adults, who underwent CT-guided removal of the nidus between November, 2004 and March, 2009 were reviewed retrospectively for demographic data, lesion site, clinical outcome and complications after procedure. Results: clinical follow-up was available for all cases at a median of 29 months (range 6-60 months). No persistence of pre-procedural pain was noted on 17 patients. Only one patient experienced recurrence of symptoms 12 months after percutaneous resection, and was successfully retreated by the same technique, resulting in a secondary success rate of 18/18 (100%). Conclusion: CT-guided removal or destruction of the nidus is a safe and effective alternative to surgical resection of the osteoid osteoma nidus. (author)

  10. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  11. Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs

    International Nuclear Information System (INIS)

    Sun, Fei; Hernandez, Javier; Crisostomo, Veronica; Pineda, Luis-Fernando; Lima, Juan Rafael; Uson, Jesus; Maynar, Manuel

    2003-01-01

    Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO 2 ) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO 2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO 2 was injected with a dedicated CO 2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO 2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO 2 , liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. (orig.)

  12. Usefulness of CT-guided trans-bronchial needle aspiration biopsy for mediastinal lymph nodes

    International Nuclear Information System (INIS)

    Cui Bing; Rong Fu

    2001-01-01

    Objective: To determine the nature of enlarged mediastinal lymph nodes, the study of CT-guided trans-bronchial needle aspiration biopsy (CT-TBNA) was conducted. Methods: According to classification and locating standard of mediastinal lymph nodes, CT-TBNA was performed in 158 mediastinal lymph nodes of 73 patients, including 54 primary lung cancer with enlarged mediastinal lymph nodes, 5 malignant lymphoma, 3 mediastinal abscess and 11 mediastinal inflammatory adenopathy. Results: CT confirmed that the needles were inside all 158 lymph nodes. Adequate aspirates for histologic and/or cytologic diagnosis were obtained in 136 of 158(86%) lymph node biopsies. No serious complications occurred. Conclusion: Locating standard of CT-guided TBNA was reliable. Puncture was safe and cost-effective. CT-TBNA was important for ascertaining the nature of mediastinal adenopathy and staging of neoplasms

  13. Diagnostic value of sonography, ultrasound-guided fine-needle aspiration cytology, and diffusion-weighted MRI in the characterization of cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Schueller-Weidekamm, Claudia [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)], E-mail: claudia.schueller-weidekamm@meduniwien.ac.at; Schueller, Gerd [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kaserer, Klaus [Department of Pathology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Scheuba, Christian [Department of Surgery, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Ringl, Helmut; Weber, Michael; Czerny, Christian; Herneth, Andreas M. [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2010-03-15

    Introduction: The purpose of this prospective study was to assess the diagnostic value of different modalities for the characterization of cold thyroid nodules. Methods: In 35 patients with cold nodules, thyroid carcinoma was suspected on scintigraphy. These patients were prospectively investigated with sonography, ultrasound-guided fine-needle aspiration (USgFNA), and quantitative diffusion-weighted imaging magnetic resonance imaging (DWI) (navigated echo-planar imaging; maximum b-value 800 s/mm{sup 2}) prior to surgery. The sonographic findings, USgFNA cytology, and the apparent diffusion coefficient (ADC) values of DWI were correlated with the postoperative histology of benign and malignant lesions. Statistical analysis was performed with the Kruskal-Wallis test and the Fisher's exact test. P < .05 denoted statistical significance. Results: The accuracy of sonography and USgFNA was 64% and 68.8%, respectively. The sensitivity was 86.7% and 80%, respectively. Specificity was only 57.2% and 50%, respectively. The median ADC values for carcinoma and adenoma were 2.73 x 10{sup -3} mm{sup 2}/s and 1.93 x 10{sup -3} mm{sup 2}/s, respectively (P < .001). There was no significant difference between the median ADC value for Hashimoto thyroiditis (3.46 x 10{sup -3} mm{sup 2}/s) and carcinoma. An ADC value of 2.25 x 10{sup -3} mm{sup 2}/s or higher was proven to be the cut-off value for differentiating between benign and malignant cold thyroid nodules, with an accuracy of 88%, a sensitivity of 85%, and a specificity of 100%. Conclusions: These results show that quantitative DWI is a more reliable diagnostic method for differentiation between benign and malignant thyroid lesions than sonography or USgFNA. However, further studies including a larger study population are necessary to confirm our study results.

  14. Scalp Melanoma Diagnosed by Fine Needle Aspiration Cytology in a Tertiary Health Center

    Directory of Open Access Journals (Sweden)

    A. B. Zarami

    2015-01-01

    Full Text Available Melanoma is one of the most aggressive malignant skin neoplasms worldwide with more than 20% of world melanoma seen in black Africa and Asia. Late presentation due to ignorance, poverty, and lack of adequate health facility in Nigeria is always the norms. We present this case report because of precision in diagnosis, using fine needle aspiration cytology (FNAC to reemphasize that the technique is cheap, cost effective, and quick that can reduce the burden of incisional biopsy before definitive surgery and improve early detection of the disease especially in developing countries.

  15. Just-in-time tomography (JiTT): a new concept for image-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pang, G; Rowlands, J A [Toronto-Sunnybrook Regional Cancer Centre, 2075 Bayview Avenue, Toronto M4N 3M5 (Canada); Imaging Research, Sunnybrook and Women' s College Health Sciences Centre, Departments of Radiation Oncology and Medical Biophysics, University of Toronto, Toronto (Canada)

    2005-11-07

    Soft-tissue target motion is one of the main concerns in high-precision radiation therapy. Cone beam computed tomography (CBCT) has been developed recently to image soft-tissue targets in the treatment room and guide the radiation therapy treatment. However, due to its relatively long image acquisition time the CBCT approach cannot provide images of the target at the instant of the treatment and thus it is not adequate for imaging targets with intrafraction motion. In this note, a new approach for image-guided radiation therapy-just-in-time tomography (JiTT)-is proposed. Differing from CBCT, JiTT takes much less time to generate the needed tomographical, beam's-eye-view images of the treatment target at the right moment to guide the radiation therapy treatment. (note)

  16. Added value of thyroglobulin measurement in the fine-needle aspiration washout to diagnose cervical metastatic lymphadenopathy from papillary thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Lan; Lee, Tae Hyun; Park, Dong Hee [Dept. of Diagnostic Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-11-15

    The aim of this study was to evaluate added value and diagnostic threshold value of thyroglobulin measurement in the fine-needle aspiration washout for detecting cervical lymph node metastasis from papillary thyroid cancer on pre and postoperative patients. Total 219 cervical lymph nodes from 180 patients with papillary thyroid cancer were evaluated for fine needle aspiration cytology and thyroglobulin in fine needle aspiration (FNA-Tg), using immunometric chemiluminescent assay. Eighty-six patients were preoperative and remaining 94 patients were on follow up after total thyroidectomy. Final diagnoses were made on pathology of dissected lymph nodes or follow-up examination for at least 12 months. One hundred and twelve metastatic lymph nodes were finally confirmed in 94 patients out of total 180 patients. Sensitivity of FNA-Tg was 99.1, 98.21, 97.20%, respectively with threshold level at 1, 10, serum Tgng/mL, which were higher sensitivity of fine needle aspiration. Combined FNA and FNA-Tg with threshold at 1, 10, 100 ng/mL raised sensitivity and specificity to 100%, respectively. All 6 lymph nodes that were false negative on FNA were correctly diagnosed as metastasis on FNA-Tg with threshold of 1, 10, 100, and serum thyroglobulin. FNA-Tg with threshold level at 100 ng/mL combined FNA showed highest sensitivity (100%) and specificity (97.56%) on preoperative patient groups among the 1, 10, 100, serum Tg threshold value. But, FNA only showed adequately high sensitivity (100%) and specificity (96.96%) on postoperative patient groups. Using receiver operating characteristic curve (ROC) curve analysis, cut off value was 57.69 in total patient, 78.66 in preoperative patient, and 32.81 in postoperative patient. FNA-Tg combined with FNA showed excellent sensitivity and specificity. FNA-Tg showed very high sensitivity and specificity at threshold level 78.66 ng/mL in preoperative patients, but FNA-Tg had less benefit on the postoperative patient group, having high

  17. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  18. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  19. Computed tomography-guided bupivacaine and corticosteroid injection for the treatment of symptomatic calcification in the great toe tendon

    Directory of Open Access Journals (Sweden)

    Karatoprak O

    2014-04-01

    Full Text Available Omer Karatoprak,1 Sinan Karaca,2 Mehmet Nuri Erdem,3 Ozgur Karaman,2 Azmi Hamzaoglu41Department of Orthopedic Surgery, Kadikoy Florence Nightingale Hospital, Istanbul, Turkey; 2Department of Orthopedic Surgery, Fatih Sultan Mehmet Training and Research Hospital Atasehir, Istanbul, Turkey; 3Department of Orthopedics and Traumatology, Kolan International Hospital Sisli, Istanbul, Turkey; 4Department of Orthopedic Surgery, Istanbul Florence Nightingale Hospital, Istanbul TurkeyBackground: Calcification in the great toe tendon is a rare disorder that is characterized by the deposition of calcium on degenerative collagen fibrils.Case presentations: In this report, we present two cases of calcific tendonitis: one in the adductor hallucis and the other in the flexor hallucis longus tendon. We preferred computed tomography-guided steroid injection in our cases because of pain unresponsive to conservative treatment. Patients were free of symptoms at the follow-up visit, 4 weeks after injection.Conclusion: Calcification of the hallux tendons is a rare disorder. Treatment of tendonitis consists of nonsteroidal anti-inflammatory drugs. Local anesthetic and steroid injection may be considered in cases unresponsive to conservative treatment. Because of the anatomic location of tendons, injection could be difficult. Computed tomography guidance may improve the success rate of injections.Keywords: bupivacaine, calcification, great toe tendons, corticosteroid injection

  20. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy

    International Nuclear Information System (INIS)

    Kim, Joshua; Zhang, Tiezhi; Lu, Weiguo

    2014-01-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source–dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10–15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source–dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented. (paper)

  1. Molecular imaging needles: dual-modality optical coherence tomography and fluorescence imaging of labeled antibodies deep in tissue

    Science.gov (United States)

    Scolaro, Loretta; Lorenser, Dirk; Madore, Wendy-Julie; Kirk, Rodney W.; Kramer, Anne S.; Yeoh, George C.; Godbout, Nicolas; Sampson, David D.; Boudoux, Caroline; McLaughlin, Robert A.

    2015-01-01

    Molecular imaging using optical techniques provides insight into disease at the cellular level. In this paper, we report on a novel dual-modality probe capable of performing molecular imaging by combining simultaneous three-dimensional optical coherence tomography (OCT) and two-dimensional fluorescence imaging in a hypodermic needle. The probe, referred to as a molecular imaging (MI) needle, may be inserted tens of millimeters into tissue. The MI needle utilizes double-clad fiber to carry both imaging modalities, and is interfaced to a 1310-nm OCT system and a fluorescence imaging subsystem using an asymmetrical double-clad fiber coupler customized to achieve high fluorescence collection efficiency. We present, to the best of our knowledge, the first dual-modality OCT and fluorescence needle probe with sufficient sensitivity to image fluorescently labeled antibodies. Such probes enable high-resolution molecular imaging deep within tissue. PMID:26137379

  2. Fine needle aspiration cytology in leprosy

    Directory of Open Access Journals (Sweden)

    Prasad PVS

    2008-01-01

    Full Text Available Background: Laboratory diagnosis of leprosy by slit skin smear and skin biopsy is simple but both techniques have their own limitations. Slit skin smear is negative in paucibacillary cases whereas skin biopsy is an invasive technique. Fine needle aspiration cytology (FNAC from skin lesions in leprosy with subsequent staining with May-Grunwald-Giemsa (MGG stain has been found useful. Aim: To evaluate the possible role of cytology in classifying leprosy patients. Methods: Seventy-five untreated cases of leprosy attending the outpatient department were evaluated. Smears were taken from their skin lesions and stained using the MGG technique. Skin biopsy was also done from the lesions, which was compared with cytology smears. Results: A correlation of clinical features with FNAC was noticed in 87.5% of TT, 92.1% of BT, 81% of BL, and 66% of LL cases. Correlation of clinical with histopathological diagnoses revealed 12.5% specificity in TT leprosy, 55.3% in BT, 52.4% in BL and 50% in LL, and 100% in neuritic and histoid leprosy cases. Both correlations were found to be statistically significant by paired t test analysis. Thus, it was possible to distinguish the tuberculoid types by the presence of epithelioid cells and the lepromatous types by the presence of lymphocytes and foamy macrophages. Conclusion: FNAC may be used to categorize the patients into paucibacillary and multibacillary types, but is not a very sensitive tool to classify the patients across the Ridley-Jopling spectrum.

  3. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  4. Detection of a coronary artery vessel wall: performance of 0.3 mm fine-cell detector computed tomography-a phantom study

    International Nuclear Information System (INIS)

    Yamada, Minoru; Jinzaki, Masahiro; Tanami, Yutaka; Matsumoto, Kazuhiro; Ueno, Akihisa; Kuribayashi, Sachio; Nukui, Masatake; Imai, Yasuhiro; Ishihara, Yotaro; Nishide, Akihiko; Sasaki, Kosuke

    2011-01-01

    The purpose of this study was to evaluate whether experimental fine-cell detector computed tomography with a 0.3125 mm cell (0.3 mm cell CT) can improve the detection of coronary vessel walls compared with conventional 64-slice computed tomography with a 0.625 mm cell (0.6 mm cell CT). A coronary vessel wall phantom was scanned using 0.6 mm cell CT and 0.3 mm cell CT. The data for 0.3 mm cell CT were obtained using four protocols: a radiation dose equal, double, triple or quadruple that were used in the 0.6 mm cell CT protocol. The detectable size of the vessel wall was assessed based on the first and second derivative functions, and the minimum measurable values were compared using a paired t-test. As a result, the minimum detectable wall thickness of 0.6 mm cell CT (1.5 mm) was significantly larger than that of 0.3 mm cell CT performed using the triple- and quadruple-dose protocols (0.9 mm) and the double-dose protocol (1.1 mm). The difference in the minimum detectable vessel wall thickness measured using 0.6 mm cell CT (1.5 ± 0.1 mm) and 0.3 mm cell CT (0.9 ± 0.1 mm, 1.1 ± 0.2 mm) was significant (p < 0.01). We concluded that 0.3 mm cell CT improved the detection of coronary vessel walls when a more than double-dose protocol was used compared with 0.6 mm cell CT.

  5. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  6. A correlation study of diagnostic fine-needle aspiration with histologic diagnosis in cystic neck lesions.

    Science.gov (United States)

    Moatamed, Neda A; Naini, Bita V; Fathizadeh, Payman; Estrella, Julie; Apple, Sophia K

    2009-10-01

    The clinical diagnosis of a mass in the neck region encompasses a wide spectrum of differential diagnosis. Fine-needle aspiration is a quick and safe technique, which can provide useful information for initial assessment and further therapeutic measures. The aim of this retrospective study was to evaluate the performance characteristics of the fine-needle aspiration (FNA) in cystic neck lesions. Of 142 patients with FNA for cystic neck masses during 2002-2007, 92 cases were selected with a follow-up histologic diagnosis, excluding the cystic colloid nodule of the thyroid. The cases were divided into salivary gland cystic neck (37 patients) and non-salivary cystic neck (55 patients) mass groups. False-positive and false-negative diagnoses were applied only to the malignant lesions after confirmation by histopathology. In the first group, nine malignant and 28 benign diagnoses were made by FNA; of which three were false-negative. In the second group, there were nine malignant and 46 benign diagnoses with three false negatives. The overall performance of the FNA showed 76% sensitivity and 100% specificity. In conclusion, FNA of the cystic neck lesions offers an invaluable and highly specific initial diagnostic approach for the management of the patients. (c) 2009 Wiley-Liss, Inc.

  7. A novel needle-type sampling device for flexible ultrathin bronchoscopy

    International Nuclear Information System (INIS)

    Suda, Yuji; Hayashi, Katsutoshi; Shindoh, Yuriko; Iijima, Hideya; Tanaka, Akiko

    2008-01-01

    Diagnosis of suspected cancer in the periphery of the lung is difficult. A flexible ultrathin bronchoscope has been developed for the diagnosis of peripherally located pulmonary lesions that cannot be reached with the sampling devices for standard flexible bronchoscopes. The diagnostic yield with forceps and a brush for ultrathin bronchoscopes, however, is not adequate, especially when a lesion is not exposed to the bronchial lumen. We have thus developed a novel needle-type sampling device and tested its yield in transbronchial cytology. The device consists of an elongated dental H-file (0.4 mm in diameter and 110 cm in length), a housing sheath (1.0 mm in outer diameter), and a novel handle, which enables rapid out-and-in motion of the needle. Ten consecutive patients with a peripheral pulmonary lesion who had an indication for diagnostic procedure with a flexible ultrathin bronchoscope were enrolled. The optimal bronchial route to the lesion was analyzed with virtual bronchoscopy in a data set obtained with high-resolution computed tomography, and a novel bronchial route labeling system (prior-ridge-based relative orientation nomenclature) was employed to guide insertion of the bronchoscope. Sampling with the novel needle was performed prior to use of the forceps and brush under conventional fluoroscopy. In all the cases, sampling with the needle was successful and the amount of the specimen was sufficient for cytology. Our novel sampling system with flexible ultrathin bronchoscopes may contribute to accurate and minimally invasive diagnosis of peripheral pulmonary lesions. (author)

  8. Computed tomography fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures

    International Nuclear Information System (INIS)

    Iguchi, Toshihiro; Ogawa, Ken-Ichi; Doi, Takeshi; Munetomo, Kazuo; Miyasho, Koji; Hiraki, Takao; Kanazawa, Susumu; Ozaki, Toshifumi

    2010-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of the computed tomography (CT) fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures. Six patients (four women and two men; mean age 55.8 years; range 35-77 years) with unstable posterior pelvic fractures underwent iliosacral screw placement under CT fluoroscopy guidance between November 2007 and August 2008. Unstable pelvic ring injury (AO types B and C) was the indication for this procedure. In all the six patients except one, CT fluoroscopy-guided placement had been technically successful. In one patient, a second screw had been inserted, with a tilt to the caudal site, and slightly advanced into the extrasacral body; afterward, it could be exchanged safely for a shorter screw. Five patients and one patient underwent placement of two screws and one screw, respectively. The mean duration of the procedure was 15.0 min (range 9-30 min) per screw; the duration was 12.3 min and 18.2 min for the first and second screws, respectively. No complications requiring treatment occurred during or after the procedure. The mean clinical and radiologic follow-up period was 14 months (range 6-21 months). All pelvic injuries had healed satisfactorily, without complication, and all patients are now doing well clinically and can walk. CT fluoroscopy-guided placement of iliosacral screws is a safe and effective treatment in patients with unstable posterior pelvic fractures. (orig.)

  9. Endometriosis presenting as inguinal mass attached to the extra pelvic part of round ligament

    International Nuclear Information System (INIS)

    Ibrahim, N.T.

    2013-01-01

    Endometriosis attached to extra pelvic part of the round ligament is rare. Preoperative diagnosis is difficult but history and presentation may guide to diagnosis which is confirmed on histology. A woman aged 29 years presented with painful right inguinal mass whose intensity of pain and size changed with menstrual cycle. Physical examination revealed right inguinal hard, fixed mass measuring 2*2 cm. Ultrasound, computed tomography, and fine needle aspiration cytology were normal therefore, excision of the mass was done along with histology which,confirmed endometriosis; simultaneous laparoscopy was performed which showed peritoneal endometriosis too. (author)

  10. Computerized tomography-guided neurolytic splanchnic nerve block

    International Nuclear Information System (INIS)

    Henriquet, Franco; De Martini, Giuseppe; Roy, Maria Teresa; Pretrolesi, Fabio; Martinoli, Carlo; Cariati, Maurizio; Fiorentini, Franco.

    1997-01-01

    Computerized tomography-guided neurolytic splanchnic nerve block is a technique for relieving abdominal cancer pain; the goal is the alcoholic neurolytic interruption of the sensitive structures in retroperitoneal space. Computerized tomography yields accurate anatomical detailing and the course for needle placement and alcohol spread. January, 1993, to July, 1996, twenty-one bilateral splanchnic nerve blocks were performed through the posterior access. Forty-eight hours after alcoholism. 14 patients (66%) had complete pain regression; 52% of the patients needed no analgesics for 6 to 54 days and only 9 patients (42%) needed another low opioid therapy. Complications included hypotension and diarrhea in all cases. One had a cardiac arrest and diet 8 days after the procedure. There were no other complications. The whole procedure usually lasted 60 min (range: 45 to 90 min). Splanchnic nerve neurolysis is a useful treatment in the patients with severe chronic abdominal pain. It is used as a second line treatment when large lesions change celia anatomy and complicate the percutaneous block of the celiac plexus. Endosulfan, Malathion and Methyl parathion, on the metabolic rate of the estuarine clam, Villorita cyprinoides var. cochinensis, have been investigated. The animals exposed to the lower sublethal concentrations of Endosulfan, Malthion and Methyl parathion consumed oxygen at the rate of 1.60, 1.98 and 2.09 ml. 0 2 g - 1 h -1 respectively, while at the higher concentrations of the pesticides, consumption of oxygen by the animal dropped to nearly half the control value. When compared to Malathion and Methyl parathion. Endosulfan induced animals recorded a greater reduction in her percentage deviation (from control) of oxygen consumption, possibly due to hypoxia induced by the pollutants

  11. Ultrasound-Guided Miniscalpel-Needle Release versus Dry Needling for Chronic Neck Pain: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Yongjun Zheng

    2014-01-01

    Full Text Available Objective. To compare ultrasound-guided miniscalpel-needle (UG-MSN release versus ultrasound-guided dry needling (UG-DN for chronic neck pain. Methods. A total of 169 patients with chronic neck pain were randomized to receive either UG-MSN release or UG-DN. Before treatment and at 3 and 6 months posttreatment, pain was measured using a 10-point visual analogue scale (VAS. Neck function was examined using the neck disability index. Health-related quality of life was examined using the physical component score (PCS and mental component score (MCS of the SF-36 health status scale. Results. Patients in the UG-MSN release had greater improvement on the VAS (by 2 points at 3 months and 0.9 points at 6 months versus in the UG-DN arm; (both P<0.0001. Patients receiving UG-MSN release also showed significantly lower scores on the adjusted neck disability index, as well as significantly lower PCS. No severe complications were observed. Conclusion. UG-MSN release was superior to UG-DN in reducing pain intensity and neck disability in patients with chronic neck pain and was not associated with severe complications. The procedural aspects in the two arms were identical; however, we did not verify the blinding success. As such, the results need to be interpreted with caution.

  12. Preoperative Computed Tomography-Guided Percutaneous Hookwire Localization of Metallic Marker Clips in the Breast with a Radial Approach: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, T.; Kasami, M.; Uchida, Y.; Sanuki, J.; Kimura, K.; Tanaka, K.; Takahashi, K. [Dept. of Diagnostic Radiology, Dept. of Pathology, and Dept. of Breast Surgery, Shizuoka Cancer Center Hospital, Naga-izumi, Shizuoka (Japan)

    2007-07-15

    Background: Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. Purpose: To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Material and Methods: Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. Results: CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). Conclusion: CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  13. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    Science.gov (United States)

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  14. [Value of ultrasonically-guided liver puncture biopsy in the diagnosis of primary liver cancer. Apropos of 84 cases].

    Science.gov (United States)

    Peghini, M; Eynard, J P; Vergne, R; Seurat, P; Barabe, P; Aubry, P; Diallo, A; Gueye, P M

    1987-01-01

    Ultrasonographicaly guided fine needle aspiration of liver was performed in 84 patients having a confirmed HCC. This technics utilizes a CHIBA type fine needle, after blood coagulation tests have been checked. Out of 84 fine needle aspirations performed: 64 were positive (76,2%), 9 negative (10,7%), 11 (13,19%) were questionable (6) or nonanalysable (5). It is ascertained that the sensibility of this technics is over 75%. It should be possible to improve it by repeating such an exam in previously negative patients. The causes of failure are discussed. Tolerance of the technics is good. It is attraumatic, and of very easily performance. No accident, no mishap was noted.

  15. Fluorescence-Guided Probes of Aptamer-Targeted Gold Nanoparticles with Computed Tomography Imaging Accesses for in Vivo Tumor Resection.

    Science.gov (United States)

    Li, Cheng-Hung; Kuo, Tsung-Rong; Su, Hsin-Jan; Lai, Wei-Yun; Yang, Pan-Chyr; Chen, Jinn-Shiun; Wang, Di-Yan; Wu, Yi-Chun; Chen, Chia-Chun

    2015-10-28

    Recent development of molecular imaging probes for fluorescence-guided surgery has shown great progresses for determining tumor margin to execute the tissue resection. Here we synthesize the fluorescent gold nanoparticles conjugated with diatrizoic acid and nucleolin-targeted AS1411 aptamer. The nanoparticle conjugates exhibit high water-solubility, good biocompatibility, visible fluorescence and strong X-ray attenuation for computed tomography (CT) contrast enhancement. The fluorescent nanoparticle conjugates are applied as a molecular contrast agent to reveal the tumor location in CL1-5 tumor-bearing mice by CT imaging. Furthermore, the orange-red fluorescence emitting from the conjugates in the CL1-5 tumor can be easily visualized by the naked eyes. After the resection, the IVIS measurements show that the fluorescence signal of the nanoparticle conjugates in the tumor is greatly enhanced in comparison to that in the controlled experiment. Our work has shown potential application of functionalized nanoparticles as a dual-function imaging agent in clinical fluorescence-guided surgery.

  16. Bayesian network modelling on data from fine needle aspiration cytology examination for breast cancer diagnosis

    OpenAIRE

    Ding, Xuemei; Cao, Yi; Zhai, Jia; Maguire, Liam; Li, Yuhua; Yang, Hongqin; Wang, Yuhua; Zeng, Jinshu; Liu, Shuo

    2017-01-01

    The paper employed Bayesian network (BN) modelling approach to discover causal dependencies among different data features of Breast Cancer Wisconsin Dataset (BCWD) derived from openly sourced UCI repository. K2 learning algorithm and k-fold cross validation were used to construct and optimize BN structure. Compared to Na‹ve Bayes (NB), the obtained BN presented better performance for breast cancer diagnosis based on fine needle aspiration cytology (FNAC) examination. It also showed that, amon...

  17. Fine needle aspiration cytology of unilesional mycosis fungoides d′emblee

    Directory of Open Access Journals (Sweden)

    K Amita

    2012-01-01

    Full Text Available Primary cutaneous T-cell lymphoma is a rare lymphoproliferative disorder accounting for 2% of all lymphomas. Mycosis fungoides (MF is a rare, albeit commonest form of primary cutaneous T cell lymphoma. MF d′emblee is an uncommon variant which is easily mistaken clinically for epithelial malignancy. Diagnosis at cytology is challenging due to low degree of suspicion, rare occurrence and diverse morphology. We report a case of 51-year-old male presenting with a solitary nodulo-ulcerative lesion over right thigh. Smear showed atypical lymphocytes with hyper-convoluted cerebriform nuclei along with few mature lymphocytes consistent with MF. To our knowledge, this is the first report of unilesional MF d′emblee diagnosed at fine needle aspiration cytology (FNAC. Our case emphasizes that FNAC is an accurate method for early diagnosis and clinical staging of patients with MF.

  18. Cone-Beam Computed Tomography (CBCT) Versus CT in Lung Ablation Procedure: Which is Faster?

    Science.gov (United States)

    Cazzato, Roberto Luigi; Battistuzzi, Jean-Benoit; Catena, Vittorio; Grasso, Rosario Francesco; Zobel, Bruno Beomonte; Schena, Emiliano; Buy, Xavier; Palussiere, Jean

    2015-10-01

    To compare cone-beam CT (CBCT) versus computed tomography (CT) guidance in terms of time needed to target and place the radiofrequency ablation (RFA) electrode on lung tumours. Patients at our institution who received CBCT- or CT-guided RFA for primary or metastatic lung tumours were retrospectively included. Time required to target and place the RFA electrode within the lesion was registered and compared across the two groups. Lesions were stratified into three groups according to their size (20 mm). Occurrences of electrode repositioning, repositioning time, RFA complications, and local recurrence after RFA were also reported. Forty tumours (22 under CT, 18 under CBCT guidance) were treated in 27 patients (19 male, 8 female, median age 67.25 ± 9.13 years). Thirty RFA sessions (16 under CBCT and 14 under CT guidance) were performed. Multivariable linear regression analysis showed that CBCT was faster than CT to target and place the electrode within the tumour independently from its size (β = -9.45, t = -3.09, p = 0.004). Electrode repositioning was required in 10/22 (45.4 %) tumours under CT guidance and 5/18 (27.8 %) tumours under CBCT guidance. Pneumothoraces occurred in 6/14 (42.8 %) sessions under CT guidance and in 6/16 (37.5 %) sessions under CBCT guidance. Two recurrences were noted for tumours receiving CBCT-guided RFA (2/17, 11.7 %) and three after CT-guided RFA (3/19, 15.8 %). CBCT with live 3D needle guidance is a useful technique for percutaneous lung ablation. Despite lesion size, CBCT allows faster lung RFA than CT.

  19. Umbilical metastasis (Sister Mary Joseph's nodule diagnosed by fine-needle aspiration

    Directory of Open Access Journals (Sweden)

    Tatomirović Željka

    2004-01-01

    Full Text Available Sister Mary Joseph’s nodule is the eponym for metastatic involvement of the umbilicus. This less common entity is the sign of disseminated malignant disease, mainly of digestive and gynecologic origin, and is associated with a poor prognosis. A case of Sister Mary Joseph’s nodule in a 76-year-old woman in whom the umbilical metastasis was the first sign of malignant disease in presented. The diagnosis of metastatic adenocarcinoma was established by fine needle aspiration cytology of the umbilical nodule. Radiological and ultrasonographic investigation disclosed carcinoma of the gallbladder with pancreas, stomach, and colon invasion as well as peritoneal dissemination. The diagnosis was confirmed by exploratory laparatomy and histological examination of the excised umbilical nodule.

  20. Osteoid osteomas in common and in technically challenging locations treated with computed tomography-guided percutaneous radiofrequency ablation

    International Nuclear Information System (INIS)

    Mylona, Sophia; Patsoura, Sofia; Karapostolakis, Georgios; Galani, Panagiota; Pomoni, Anastasia; Thanos, Loukas

    2010-01-01

    To evaluate the efficacy of computed tomography (CT)-guided radiofrequency (RF) ablation for the treatment of osteoid osteomas in common and in technically challenging locations. Twenty-three patients with osteoid osteomas in common (nine cases) and technically challenging [14 cases: intra-articular (n = 7), spinal (n = 5), metaphyseal (n = 2)] positions were treated with CT-guided RF ablation. Therapy was performed under conscious sedation with a seven-array expandable RF electrode for 8-10 min at 80-110 C and power of 90-110 W. The patients went home under instruction. A brief pain inventory (BPI) score was calculated before and after (1 day, 4 weeks, 6 months and 1 year) treatment. All procedures were technically successful. Primary clinical success was 91.3% (21 of total 23 patients), despite the lesions' locations. BPI score was dramatically reduced after the procedure, and the decrease in BPI score was significant (P < 0.001, paired t-test; n - 1 = 22) for all periods during follow up. Two patients had persistent pain after 1 month and were treated successfully with a second procedure (secondary success rate 100%). No immediate or delayed complications were observed. CT-guided RF ablation is safe and highly effective for treatment of osteoid osteomas, even in technically difficult positions. (orig.)

  1. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  2. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  3. Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.

    Science.gov (United States)

    Tudor, G R; Rodgers, P M; West, K P

    1999-08-01

    Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.

  4. Pediatric computed tomography dose of head and chest exams: a bibliography revision

    International Nuclear Information System (INIS)

    Friedrich, Barbara Q.; Capaverde, Alexandre S.; Vanni, Stefania; Mazzola, Carolina F.S.; Silva, Ana M. Marques da

    2015-01-01

    The Computed Tomography (CT) imaging diagnosis it is responsible for over 34% of the radiation dose given to society, only in Brazil there is around 3833 CT equipment. There are two dose index in CT, the CTDI vol and DLP that represents the Computed Tomography dose index and the product of the CTDI vol by the length of irradiation. This paper has as objective describe the values of CTDI vol e DLP for pediatric exams of chest and head. This is an exploratory study of bibliography revision on the PubMed data base using the index terms with the following crossing: Computed Tomography AND Reference Levels AND Dose. The search was limited by published studies on the last 5 years with patients among 0 and 15 years, in English or Portuguese. Besides that, were included references guides suggest by scientific and governmental organizations on the last 5 years. The data analysis was made using the four readings of Gil: exploratory, selective, analytic and interpretative. By the Exploratory Reading were located 23 articles. On the Selective Reading were excluded 4 articles and on the Analytic Reading 9 articles. The Interpretative Reading was made using 7 publications. Regarding the references guides were includes 3 guides. The Portaria MS453/98 was included for being the only national publication. All data were characterized between practical levels and reference levels. The conclusion is that there is no consensus between the reference levels for the selected articles, for pediatric exams. Besides that, the national legislation do not have reference levels for pediatric CT. (author)

  5. Brain areas involved in acupuncture needling sensation of de qi: a single-photon emission computed tomography (SPECT) study.

    Science.gov (United States)

    Chen, Jia-Rong; Li, Gan-Long; Zhang, Gui-Feng; Huang, Yong; Wang, Shu-Xia; Lu, Na

    2012-12-01

    De qi is a sensory response elicited by acupuncture stimulation. According to traditional Chinese medicine (TCM), de qi is essential for clinical efficacy. However, the understanding of the neurobiological basis of de qi is still limited. To investigate the relationship between brain activation and de qi by taking a single-photon emission computed tomography (SPECT) scan while applying acupuncture at TE5. A total of 24 volunteers were randomly divided into 4 groups, and received verum or sham acupuncture at true acupuncture point TE5 or a nearby sham point according to grouping. All subjects then received a (99m)Tc-ethylcysteinate dimer (ECD) SPECT scan. All six subjects in the verum acupuncture at true acupuncture point group experienced de qi sensation; in contrast, all six subjects in the sham acupuncture at the sham point group responded with nothing other than non-sensation. Compared to the scan results from subjects who experienced non-sensation, SPECT scans from subjects with de qi sensation demonstrated significant activated points mainly located in brodmann areas 6, 8, 19, 21, 28, 33, 35, 37, 47, the parahippocampal gyrus, lentiform nucleus, claustrum and red nucleus; deactivated points were seen in brodmann areas 9 and 25. Verum acupuncture at true acupuncture points is more likely to elicit de qi sensation. De qi sensations mainly resulted in brain area activations, but not deactivations. These brain areas are related to the curative effect of Te5. The acupuncture needle sensations of de qi and sharp pain are associated with different patterns of activations and deactivations in the brain.

  6. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    Science.gov (United States)

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (Ptennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  7. Demonstration of arterioportal shunt by dynamic computed tomography and its diagnostic value

    International Nuclear Information System (INIS)

    Nakayama, Takatsune; Hiyama, Yoshiaki; Saitoh, Masayuki

    1983-01-01

    Sixty-one patients, 41 with hepatocellular carcinoma and 20 with liver cirrhosis, were examined by dynamic computed tomography (CT) and all but one with hepatocellular carcinoma were examined by celiac angiography. Dynamic CT disclosed arterioportal shunting in eleven cases of hepatocellular carcinima and in one of cirrhotics. All of them were confirmed by angiography except one case in which angiography could not be performed. In ten of these eleven cases arterioportal shunt was adjacent to a mass lesion on dynamic CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In one with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneus needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus dynamic CT was nearly as diagnostic as celiac arterigraphy for the demonstration of arterioportal shunt due to portal invasion of hepatocellular carcinoma and percutaneus needle puncture. (author)

  8. Demonstration of arterioportal shunt by dynamic computed tomography and its diagnostic value

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Takatsune; Hiyama, Yoshiaki; Saitoh, Masayuki

    1983-11-01

    Sixty-one patients, 41 with hepatocellular carcinoma and 20 with liver cirrhosis, were examined by dynamic computed tomography (CT) and all but one with hepatocellular carcinoma were examined by celiac angiography. Dynamic CT disclosed arterioportal shunting in eleven cases of hepatocellular carcinoma and in one of cirrhotics. All of them were confirmed by angiography except one case in which angiography could not be performed. In ten of these eleven cases arterooportal shunt was adjacent to a mass lesion on dynamic CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In one with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneus needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus dynamic CT was nearly as diagnostic as celiac arterigraphy for the demonstration of arterioportal shunt due to portal invasion of hepatocellular carcinoma and percutaneus needle puncture.

  9. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017.

    Science.gov (United States)

    Polkowski, Marcin; Jenssen, Christian; Kaye, Philip; Carrara, Silvia; Deprez, Pierre; Gines, Angels; Fernández-Esparrach, Gloria; Eisendrath, Pierre; Aithal, Guruprasad P; Arcidiacono, Paolo; Barthet, Marc; Bastos, Pedro; Fornelli, Adele; Napoleon, Bertrand; Iglesias-Garcia, Julio; Seicean, Andrada; Larghi, Alberto; Hassan, Cesare; van Hooft, Jeanin E; Dumonceau, Jean-Marc

    2017-10-01

    For routine EUS-guided sampling of solid masses and lymph nodes (LNs) ESGE recommends 25G or 22G needles (high quality evidence, strong recommendation); fine needle aspiration (FNA) and fine needle biopsy (FNB) needles are equally recommended (high quality evidence, strong recommendation).When the primary aim of sampling is to obtain a core tissue specimen, ESGE suggests using 19G FNA or FNB needles or 22G FNB needles (low quality evidence, weak recommendation).ESGE recommends using 10-mL syringe suction for EUS-guided sampling of solid masses and LNs with 25G or 22G FNA needles (high quality evidence, strong recommendation) and other types of needles (low quality evidence, weak recommendation). ESGE suggests neutralizing residual negative pressure in the needle before withdrawing the needle from the target lesion (moderate quality evidence, weak recommendation).ESGE does not recommend for or against using the needle stylet for EUS-guided sampling of solid masses and LNs with FNA needles (high quality evidence, strong recommendation) and suggests using the needle stylet for EUS-guided sampling with FNB needles (low quality evidence, weak recommendation).ESGE suggests fanning the needle throughout the lesion when sampling solid masses and LNs (moderate quality evidence, weak recommendation).ESGE equally recommends EUS-guided sampling with or without on-site cytologic evaluation (moderate quality evidence, strong recommendation). When on-site cytologic evaluation is unavailable, ESGE suggests performance of three to four needle passes with an FNA needle or two to three passes with an FNB needle (low quality evidence, weak recommendation).For diagnostic sampling of pancreatic cystic lesions without a solid component, ESGE suggests emptying the cyst with a single pass of a 22G or 19G needle (low quality evidence, weak recommendation). For pancreatic cystic lesions with a solid component, ESGE suggests sampling of the solid component using the same technique as in the

  10. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  11. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  12. Proposal of a technical guide for the evaluation and management of the solitary pulmonary nodule in function of the radiological characteristics obtained by computed tomography

    International Nuclear Information System (INIS)

    Clinton Hidalgo, Carolina

    2015-01-01

    A guide is proposed to guide clinical personnel in early diagnosis, assessment and management of the solitary pulmonary nodule, with high potential of to develop lung cancer, in function of the radiological characteristics obtained by computed tomography. The management of patients with diagnosis of solitary pulmonary nodule is standardized with the purpose of to unify diagnostic criteria in a multidisciplinary and institutional environment. Tomographic radiological characteristics are described to allow the suspicion of the solitary pulmonary nodule benignity or malignity. A flow diagram is developed to guide the physician to an adequate monitoring, control and eventual therapeutic treatment. A clear and structured perspective of the diagnostic and therapeutic process is provided to the treating physician and patient [es

  13. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  14. Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

    Science.gov (United States)

    Ahmad, Moiz; Balter, Peter; Pan, Tinsu

    2011-10-01

    Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4-6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3-8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm

  15. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  16. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Si Yoon; Kwon, Jong Won [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-11-15

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect.

  17. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    International Nuclear Information System (INIS)

    Sung, Si Yoon; Kwon, Jong Won

    2015-01-01

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect

  18. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    Science.gov (United States)

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  19. Automatic entry point planning for robotic post-mortem CT-based needle placement.

    Science.gov (United States)

    Ebert, Lars C; Fürst, Martin; Ptacek, Wolfgang; Ruder, Thomas D; Gascho, Dominic; Schweitzer, Wolf; Thali, Michael J; Flach, Patricia M

    2016-09-01

    Post-mortem computed tomography guided placement of co-axial introducer needles allows for the extraction of tissue and liquid samples for histological and toxicological analyses. Automation of this process can increase the accuracy and speed of the needle placement, thereby making it more feasible for routine examinations. To speed up the planning process and increase safety, we developed an algorithm that calculates an optimal entry point and end-effector orientation for a given target point, while taking constraints such as accessibility or bone collisions into account. The algorithm identifies the best entry point for needle trajectories in three steps. First, the source CT data is prepared and bone as well as surface data are extracted and optimized. All vertices of the generated surface polygon are considered to be potential entry points. Second, all surface points are tested for validity within the defined hard constraints (reachability, bone collision as well as collision with other needles) and removed if invalid. All remaining vertices are reachable entry points and are rated with respect to needle insertion angle. Third, the vertex with the highest rating is selected as the final entry point, and the best end-effector rotation is calculated to avoid collisions with the body and already set needles. In most cases, the algorithm is sufficiently fast with approximately 5-6 s per entry point. This is the case if there is no collision between the end-effector and the body. If the end-effector has to be rotated to avoid collision, calculation times can increase up to 24 s due to the inefficient collision detection used here. In conclusion, the algorithm allows for fast and facilitated trajectory planning in forensic imaging.

  20. Huge pelvic parachordoma: fine needle aspiration cytology and histological differential diagnosis

    Directory of Open Access Journals (Sweden)

    Mona A. Kandil

    2012-10-01

    Full Text Available Parachordoma is an extremely rare soft tissue tumor of unknown lineage. Parachordoma develops most often on the extremities. Only 2 cases have been reported as pelvic parachordoma. A 46-year old Egyptian woman with a huge painful pelvic mass was found to have a parachordoma with ectopic pelvic right kidney. There is only one report in the literature of fine needle aspiration cytology in this setting. The microscopic picture of parachordoma is not new to pathologists but the gross picture of this rare tumor has not previously been published; not even in the World Health Organization classification of soft tissues tumors. Diagnosis was confirmed by immuno-histochemistry. The patient is in good clinical condition without any evidence of recurrence or metastasis after 84 months of follow up.

  1. Impact of Molecular Screening for Point Mutations and Rearrangements in Routine Air-Dried Fine-Needle Aspiration Samples of Thyroid Nodules

    DEFF Research Database (Denmark)

    Eszlinger, Markus; Krogdahl, Annelise; Münz, Sina

    2014-01-01

    Background: The diagnostic limitations of thyroid fine-needle aspiration (FNA), such as the indeterminate category, can be partially overcome by molecular analyses. However, until now, rearrangements have only been detected in fresh FNA material and the number of follicular thyroid carcinomas (FT...

  2. Percutaneous computed tomography-guided ethanol injection in aldosterone-producing adrenocortical adenoma

    International Nuclear Information System (INIS)

    Rossi, R.; Savastano, S.; Tommaselli, A.P.

    1995-01-01

    The feasibility, safety and effectiveness of percutaneous computed tomography-guided ethanol injection (PEI-CT) was investigated in a patient affected by aldosterone-producing adenoma (APA). A 42-year-old male patient with typical features of hyperaldosteronism presented a solitary left adrenal adenoma measuring 2 cm, with a normal contralateral gland, evidenced by both CT scan and adrenal [ 75 Se-19]-nor-cholesterol scintigraphy. After normalization of potassium plasma levels, 4 ml of sterile 95% ethanol with 0.5 ml of 80% iothalamate sodium was injected. The procedure was completed in about 30 min. No severe pain or local complication was noted. Five hour after PEI, a fourfold and a twofold increase in aldosterone and cortisol plasma levels were observed, respectively. After 11 days on a normal sodium and potassium diet, normal potassium plasma levels and reduced aldosterone plasma levels were present, with reappearance of an aldosterone postural response. Plasma renin activity and aldosterone plasma levels normalized 1 month later, with reappearance also of a plasma renin activity postural response and maintenance of normal potassium plasma levels on a high sodium and normal potassium diet. The patient has remained hypertensive, although lower antihypertensive drug dosages have been employed. After 17 months, normal biochemical, hormonal and morphological findings were present. The authors suggested PEI-CT as a further alternative approach to surgery in the management of carefully selected patients with APA. 15 refs., 2 figs., 1 tab

  3. Thyroid Fine-Needle Aspiration under Ultrasound Guidance: Experience from an Academic Tertiary Care Center in Lebanon

    Directory of Open Access Journals (Sweden)

    Rita Hajj Boutros

    2017-07-01

    Full Text Available Thyroid nodules are common. Malignancy was reported in only 5-15% of cases. Fine needle aspiration under US guidance (USG-FNA proved to be accurate for the detection of thyroid cancer. This is a retrospective review of 400 radiology and cytology USG-FNA reports, randomly selected among those done at the Radiology Department at a tertiary care center in Beirut during the last five years. The specimen was inadequate in 60 (12% of cases but FNA was repeated in 10 cases only. The final diagnosis was benign in 76.7% of cases, mostly in women. 35% of the malignant and 19% of the benign nodules were hypoechoic, p=0.03. No significant correlation was observed between malignancy and other ultrasonic characteristics. Hypoechogenecity was also more common in nodules with inadequate specimen (40% versus 21.4%, p=0.01. Age, gender, location and size of the nodule did not differ between groups of adequate and inadequate specimen. In conclusion, 3 out of 4 thyroid nodules referred for USG-FNA are benign, mostly in women. Inadequate specimen was observed in 12% of cases. Hypoechogenecity but not other ultrasonic characteristics was associated with malignancy and with test failure.   Key words: Thyroid nodule, fine needle aspirate, ultrasound guidance, thyroid cancer, inadequate.

  4. Cytopathologist-performed and ultrasound-guided fine needle aspiration cytology enhances diagnostic accuracy and avoids pitfalls: An overview of 20 years of personal experience with a selection of didactic cases.

    Science.gov (United States)

    Paksoy, Nadir; Ozbek, Busra

    2018-01-01

    Over the last few decades, fine needle aspiration cytology (FNA) has emerged as a SAFE (Simple, Accurate, Fast, Economical) diagnostic tool based on the morphologic evaluation of cells. The first and most important step in obtaining accurate results from FNA is to procure sufficient and representative material from the lesion and to appropriately transfer this material to the laboratory. Unfortunately, the most important aspect of this task occurs beyond the control of the cytopathologist, a key reason for obtaining unsatisfactory results with FNA. There is growing interest in the field of cytology in "cytopathologist-performed ultrasound (US)-guided FNA," which has been reported to yield accurate results. The first author has been applying FNA in his own private cytopathology practice with a radiologist and under the guidance of US for more than 20 years. This study retrospectively reviews the utility of this practice. We present a selection of didactic examples under different headings that highlight the application of FNA by a cytopathologist, accompanied by US, under the guidance of a radiologist, in the form of an "outpatient FNA clinic." The use of this technique enhances diagnostic accuracy and prevents pitfalls. The highlights of each case are also outlined as "take-home messages."

  5. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  6. Role of 18F fluorodeoxyglucose positron emission tomography/computed tomography in the detection of recurrence in patients with cervical cancer

    International Nuclear Information System (INIS)

    Bhoil, Amit; Mittal, Bhagwant Rai; Bhattacharya, Anish; Santhosh, Sampath; Patel, Firuza

    2013-01-01

    Treatment of cervical cancer is usually surgery in the early stages and radiotherapy or chemoradiotherapy in more advanced stages of the disease. Recurrence may occur in multiple sites following primary treatment. Although recurrent metastatic disease is not curable, surgical treatment may be of great help if locoregional recurrence is detected early. Fluorine-18 Fluorodeoxyglucose positron emission tomography - computed tomography ( 18 F FDG PET/CT) forms an important part of investigations in the diagnosis of clinically suspicious recurrent cervical cancer. To assess the role of 18 F FDG PET/CT in diagnosing recurrence in patients with clinical suspicion of recurrent cervical cancer. We retrospectively evaluated 53 histopathologically proved patients of cervical cancer. All the patients had been treated with either surgery/radiation therapy with or without chemotherapy. The standard PET/CT acquisition protocol, with delayed post void static pelvic images, wherever required, was followed in all patients. Significant uptake of FDG in the lymph nodes was considered to be a recurrence suggestive of metastasis. Para-aortic lymph nodal involvement was considered to be distant metastasis. Any significant uptake in the lung nodule on FDG PET was evaluated either by histological confirmation, by taking fine needle aspiration cytology (FNAC), or by a follow-up chest CT done after three months. Of the 53 patients with clinically equivocal recurrence, FDG PET/CT suggested recurrence in 41 patients (local recurrence in 14 patients and distant recurrence/metastasis with or without local recurrence in 27 patients). It had a sensitivity of 97.5%, a specificity of 63.6%, positive predictive value of 90.9%, and negative predictive value of 87.5%. PET/CT appears to have an important role in detecting recurrence following primary treatment of cervical cancer. The high positive and negative predictive values of PET/CT may be helpful in planning management of recurrent cervical cancer

  7. Lung malignancy: Diagnostic accuracies of bronchoalveolar lavage, bronchial brushing, and fine needle aspiration cytology

    Science.gov (United States)

    Sareen, Rateesh; Pandey, C L

    2016-01-01

    Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  9. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  10. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  11. Technical competence in cardiovascular magnetic resonance and computed tomography

    International Nuclear Information System (INIS)

    Fernandes, Juliano Lara; Shiozaki, Afonso Akio; Azevedo Filho, Clerio Francisco de; Rochitte, Carlos Eduardo; Pinto, Ibraim Marciarelli Francisco; Lopes, Marly Maria Uellendahl; Schvartzman, Paulo Roberto

    2009-01-01

    Cardiovascular magnetic resonance and computed tomography have evolved as very practical and useful techniques applied in clinical cardiology. Due to their rapid acceptance in the cardiology community and widespread use, training of both cardiologists and radiologists on this subspecialty has not been homogeneous so far. This in part explains significant differences observed in the diverse background found in today’s practicing physicians who execute these exams. In order to guide training facilities as well as both payers, contractors and general cardiologists ordering the exam, this document provides a minimum standard that should be accomplished by all physicians who pursue education in the field and for those who already practice in it. The clinical competences listed in this statement are by no means thorough but should be required by all those involved in cardiovascular magnetic resonance and computed tomography as the customary requirements for current and future practitioners. (author)

  12. CT-guided needle biopsy of lung lesions: A survey of severe complication based on 9783 biopsies in Japan

    International Nuclear Information System (INIS)

    Tomiyama, Noriyuki; Yasuhara, Yoshifumi; Nakajima, Yasuo; Adachi, Shuji; Arai, Yasuaki; Kusumoto, Masahiko; Eguchi, Kenji; Kuriyama, Keiko; Sakai, Fumikazu; Noguchi, Masayuki; Murata, Kiyoshi; Murayama, Sadayuki; Mochizuki, Teruhito; Mori, Kiyoshi; Yamada, Kozo

    2006-01-01

    Purpose: The aim of our study was to update the rate of severe complications following CT-guided needle biopsy in Japan via a mailed survey. Materials and methods: Postal questionnaires regarding CT-guided needle biopsy were sent out to multiple hospitals in Japan. The questions regarded: the total number and duration of CT-guided lung biopsies performed at each hospital, and the complication rates and numbers of pneumothorax, hemothorax, air embolism, tumor seeding, tension pneumothorax and other rare complications. Each severe complication was followed with additional questions. Results: Data from 9783 biopsies was collected from 124 centers. Pneumothorax was the most common complication, and occurred in 2412 (35%) of 6881 cases. A total of 39 (35%) hospitals reported 74 (0.75%) cases with severe complications. There were six cases (0.061%) with air embolism, six cases (0.061%) with tumor seeding at the site of the biopsy route, 10 cases (0.10%) with tension pneumothorax, six cases (0.061%) with severe pulmonary hemorrhage or hemoptysis, nine cases (0.092%) with hemothorax, and 27 cases (0.26%) with others, including heart arrest, shock, and respiratory arrest. From a total of 62 patients with severe complications, 54 patients (0.55%) recovered without sequela, however one patient (0.01%) recovered with hemiplegia due to cerebral infarction, and the remaining seven patients (0.07%) died. Conclusions: This is the first national study documenting severe complications with respect to CT-guided needle biopsy in Japan. The complication rate in Japan is comparable to internationally published figures. We believe this data will improve both clinicians as well as patients understanding of the risk versus benefit of CT-guided needle biopsy, resulting better decisions

  13. Computed tomography-guided interstitial high dose rate brachytherapy for centrally located liver tumours: a single institution study

    Energy Technology Data Exchange (ETDEWEB)

    Tselis, Nikolaos; Chatzikonstantinou, Georgios; Zamboglou, Nikolaos [Klinikum Offenbach, Department of Radiation Oncology, Offenbach am Main (Germany); Kolotas, Christos [Hirslanden Medical Center, Institute for Radiotherapy, Aarau (Switzerland); Milickovic, Natasa; Baltas, Dimos [Klinikum Offenbach, Department of Medical Physics and Engineering, Offenbach am Main (Germany)

    2013-08-15

    To evaluate the clinical outcome of computed tomography (CT)-guided interstitial (IRT) high-dose-rate (HDR) brachytherapy (BRT) in the treatment of unresectable primary and secondary liver malignancies. This report updates and expands our previously described experience with this treatment technique. Forty-one patients with 50 tumours adjacent to the liver hilum and bile duct bifurcation were treated in 59 interventions of CT-guided IRT HDR BRT. The tumours were larger than 4 cm with a median volume of 84 cm{sup 3} (38-1,348 cm{sup 3}). The IRT HDR BRT delivered a median total physical dose of 20.0 Gy (7.0-32.0 Gy) in twice daily fractions of median 7.0 Gy (4.0-10.0 Gy) in 19 patients and in once daily fractions of median 8.0 Gy (7.0-14.0 Gy) in 22 patients. With a median follow-up of 12.4 months, the local control for metastatic hepatic tumours was 89 %, 73 % and 63 % at 6, 12 and 18 months respectively. The local control for primary hepatic tumours was 90 %, 81 % and 50 % at 6, 12 and 18 months respectively. Severe side effects occurred in 5.0 % of interventions with no treatment-related deaths. CT-guided IRT HDR BRT is a promising procedure for the radiation treatment of centrally located liver malignancies. (orig.)

  14. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  15. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  16. Fluoroscopically Guided Extraforaminal Cervical Nerve Root Blocks: Analysis of Epidural Flow of the Injectate with Respect to Needle Tip Position

    Science.gov (United States)

    Shipley, Kyle; Riew, K. Daniel; Gilula, Louis A.

    2013-01-01

    Study Design Retrospective evaluation of consecutively performed fluoroscopically guided cervical nerve root blocks. Objective To describe the incidence of injectate central epidural flow with respect to needle tip position during fluoroscopically guided extraforaminal cervical nerve root blocks (ECNRBs). Methods Between February 19, 2003 and June 11, 2003, 132 consecutive fluoroscopically guided ECNRBs performed with contrast media in the final injected material (injectate) were reviewed on 95 patients with average of 1.3 injections per patient. Fluoroscopic spot images documenting the procedure were obtained as part of standard quality assurance. An independent observer not directly involved in the procedures retrospectively reviewed the images, and the data were placed into a database. Image review was performed to determine optimal needle tip positioning for injectate epidural flow. Results Central epidural injectate flow was obtained in only 28.9% of injections with the needle tip lateral to midline of the lateral mass (zone 2). 83.8% of injectate went into epidural space when the needle tip was medial to midline of the lateral mass (zone 3). 100% of injectate flowed epidurally when the needle tip was medial to or at the medial cortex of the lateral mass (zone 4). There was no statistically significant difference with regards to central epidural flow and the needle tip position on lateral view. Conclusion To ensure central epidural flow with ECNRBs one must be prepared to pass the needle tip medial to midplane of the lateral mass or to medial cortex of the lateral mass. Approximately 16% of ECNRBs with needle tip medial to midline of the lateral mass did not flow into epidural space. One cannot claim a nerve block is an epidural block unless epidural flow of injectate is observed. PMID:24494176

  17. Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients: A Case Report.

    Science.gov (United States)

    Oh, Ji-Hyeon; An, Xueyin; Jeong, Seung-Mi; Choi, Byung-Ho

    2017-12-01

    The purpose of this article was to describe a fully digital workflow used to perform computer-guided flapless implant placement in an edentulous patient without the use of conventional impressions, models, or a radiographic guide. Digital data for the workflow were acquired using an intraoral scanner and cone-beam computed tomography (CBCT). The image fusion of the intraoral scan data and CBCT data was performed by matching resin markers placed in the patient's mouth. The definitive digital data were used to design a prosthetically driven implant position, surgical template, and computer-aided design and computer-aided manufacturing fabricated fixed dental prosthesis. The authors believe this is the first published case describing such a technique in computer-guided flapless implant surgery for edentulous patients. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation.

    Science.gov (United States)

    Limmer, Alexandra M; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  19. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    Directory of Open Access Journals (Sweden)

    Alexandra M. Limmer

    2017-01-01

    Full Text Available Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient’s caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  20. What is the added value of combined core biopsy and fine needle aspiration in the diagnostic process of renal tumours?

    NARCIS (Netherlands)

    Barwari, K.; Kümmerlin, I.P.E.D.; Ten Kate, F.J.; Algaba, F.; Trias, I.; Wijkstra, H.; Rosette, de la J.J.M.C.H.; Laguna, M.P.

    2013-01-01

    Purpose Non-diagnostic results still hinder the routine use of core biopsy (CB) and fine needle aspiration (FNA) in the diagnostic process of renal tumours. Furthermore, substantial interobserver variability has been reported. We assessed the added value of combining the results of CB and FNA by

  1. What is the added value of combined core biopsy and fine needle aspiration in the diagnostic process of renal tumours?

    NARCIS (Netherlands)

    Barwari, K.; Kummerlin, I. P.; ten Kate, F. J.; Algaba, F.; Trias, I.; Wijkstra, H.; de la Rosette, J. J.; Laguna, P.

    2013-01-01

    Non-diagnostic results still hinder the routine use of core biopsy (CB) and fine needle aspiration (FNA) in the diagnostic process of renal tumours. Furthermore, substantial interobserver variability has been reported. We assessed the added value of combining the results of CB and FNA by five

  2. [Quality assurance of fine-needle aspiration cytology of the organized mammography screening].

    Science.gov (United States)

    Bak, Mihály; Konyár, Eva; Schneider, Ferenc; Bidlek, Mária; Szabó, Eva; Nyári, Tibor; Godény, Mária; Kásler, Miklós

    2010-08-08

    The National Public Health Program has established the organized mammography screening in Hungary. The aim of our study was to determine the quality assurance of breast aspiration cytology. Cytology results were rated to 5 categories (C1, C2, C3, C4 and C5). All cytology reports were compared with the final histology diagnosis. 1361 women had aspiration cytology diagnosis performed from a total of 47718 mammography non-negative lesions. There were 805 (59.1%) benign and 187 (13.7%) malignant alterations. Sensitivity was 91%, specificity 88%, positive predictive value 96.6% and negative predictive value turned to be 71% (pauditing values of fine needle aspiration cytology in our laboratory meet, or in certain aspects exceed the proposed minimum threshold values.

  3. Thyroid nodules with isolated macrocalcification: Malignancy and diagnostic efficacy of fine-needle aspiration and core needle biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Na, Dong Gyu; Kim, Dae Sik; Kim, Soo Jin [Dept. of Radiology, Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of); Ryoo, Jae Wook [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Jung, So Lyung [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2016-07-15

    This study was performed to determine the malignancy risk of thyroid nodules with isolated macrocalcification and to evaluate the diagnostic efficacy of fine-needle aspiration (FNA) and core needle biopsy (CNB). From May 2008 to December 2014, a total of 44 patients with isolated macrocalcifications were enrolled from 4,081 consecutive patients who underwent FNA or CNB at a single institution. We assessed the malignancy risk of nodules with isolated macrocalcification. We compared the diagnostic results between FNA and CNB, and the diagnostic efficacy of each procedure was evaluated by the rate of inconclusive results. We compared the diagnostic performance for malignancy between FNA and CNB with a criterion of malignant or atypia/follicular lesion of undetermined significance (indeterminate) diagnostic results. We investigated whether the ultrasonographic feature of isolated macrocalcification was predictive of malignancy. The malignancy risk of nodules with isolated macrocalcification was 16.1% in 31 nodules with final diagnoses and 11.4% in all nodules. CNB demonstrated a significantly lower rate of nondiagnostic and inconclusive results than FNA (7.7% vs. 53.8%, P=0.002 and 15.4% vs. 57.7%, P=0.003, respectively) in 26 nodules that underwent both FNA and CNB. CNB showed a marginally higher diagnostic performance for identifying malignancy than FNA (P=0.067). The ultrasonographic features of the anterior margin of isolated macrocalcification were not predictive of malignancy (P>0.999). Thyroid nodules with isolated macrocalcification had a low to intermediate malignancy risk and should not be considered benign nodules. CNB showed a higher diagnostic efficacy than FNA in these nodules.

  4. Thyroid nodules with isolated macrocalcification: Malignancy and diagnostic efficacy of fine-needle aspiration and core needle biopsy

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Kim, Dae Sik; Kim, Soo Jin; Ryoo, Jae Wook; Jung, So Lyung

    2016-01-01

    This study was performed to determine the malignancy risk of thyroid nodules with isolated macrocalcification and to evaluate the diagnostic efficacy of fine-needle aspiration (FNA) and core needle biopsy (CNB). From May 2008 to December 2014, a total of 44 patients with isolated macrocalcifications were enrolled from 4,081 consecutive patients who underwent FNA or CNB at a single institution. We assessed the malignancy risk of nodules with isolated macrocalcification. We compared the diagnostic results between FNA and CNB, and the diagnostic efficacy of each procedure was evaluated by the rate of inconclusive results. We compared the diagnostic performance for malignancy between FNA and CNB with a criterion of malignant or atypia/follicular lesion of undetermined significance (indeterminate) diagnostic results. We investigated whether the ultrasonographic feature of isolated macrocalcification was predictive of malignancy. The malignancy risk of nodules with isolated macrocalcification was 16.1% in 31 nodules with final diagnoses and 11.4% in all nodules. CNB demonstrated a significantly lower rate of nondiagnostic and inconclusive results than FNA (7.7% vs. 53.8%, P=0.002 and 15.4% vs. 57.7%, P=0.003, respectively) in 26 nodules that underwent both FNA and CNB. CNB showed a marginally higher diagnostic performance for identifying malignancy than FNA (P=0.067). The ultrasonographic features of the anterior margin of isolated macrocalcification were not predictive of malignancy (P>0.999). Thyroid nodules with isolated macrocalcification had a low to intermediate malignancy risk and should not be considered benign nodules. CNB showed a higher diagnostic efficacy than FNA in these nodules

  5. Paraganglioma with unusual presentation in parotid gland: A diagnostic dilemma in fine needle aspiration

    Directory of Open Access Journals (Sweden)

    Anagh A Vora

    2012-01-01

    Full Text Available Paragangliomas (PGLs are uncommon tumors. Although PGLs are known to occur in the head and neck region, especially the carotid body, middle ear, and larynx, involvement of the parotid glands has not been reported. In this article, we report the fine needle aspiration features of tumor in an unusual location, presenting as a parotid gland mass, submitted to pathology for initial diagnosis. The clinical presentation, cytomorphology, and the immunohistochemical features for the diagnosis are described. To our knowledge, this is the first case of paraganglioma of the parotid gland reported in the literature.

  6. Lymphography with percutaneous fine needle cytology for the detection of malignant lymph node involvement

    International Nuclear Information System (INIS)

    Fencl, P.; Mylbachr, L.; Neradov, M.; Starek, J.; Doleckova, M.

    1988-01-01

    The authors present their experience of lymphograpy and percutaneous fine needle cytological biopsy of 60 patients with malignancies. Cytological specimens were taken from 98 lymph nodes in patients with cervical cancer (36), vulvar cancer (2), uterine sarcoma (2), vesical cancer (2), prostate gland cancer (3), Hodgkin's lymphoma (4), non Hodgkin's lymphoma (6), seminoma (4), lung cancer (1). Malignant cells were found in 31 persons in 41 nodes. Half of the dubious lymphography nodes had malignant cells in the biopsy material. Curiously enough, the contrast medium causes granulomatous inflammation of time-dependent intensity. 3 refs.; 2 figs.; 2 tabs

  7. Teleoperation of steerable flexible needles by combining kinesthetic and vibratory feedback.

    Science.gov (United States)

    Pacchierotti, Claudio; Abayazid, Momen; Misra, Sarthak; Prattichizzo, Domenico

    2014-01-01

    Needle insertion in soft-tissue is a minimally invasive surgical procedure that demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and responsibility, autonomous robotic control is often not desirable. Therefore, it is necessary to focus also on techniques enabling clinicians to directly control the motion of the surgical tools. In this work, we address that challenge and present a novel teleoperated robotic system able to steer flexible needles. The proposed system tracks the position of the needle using an ultrasound imaging system and computes needle's ideal position and orientation to reach a given target. The master haptic interface then provides the clinician with mixed kinesthetic-vibratory navigation cues to guide the needle toward the computed ideal position and orientation. Twenty participants carried out an experiment of teleoperated needle insertion into a soft-tissue phantom, considering four different experimental conditions. Participants were provided with either mixed kinesthetic-vibratory feedback or mixed kinesthetic-visual feedback. Moreover, we considered two different ways of computing ideal position and orientation of the needle: with or without set-points. Vibratory feedback was found more effective than visual feedback in conveying navigation cues, with a mean targeting error of 0.72 mm when using set-points, and of 1.10 mm without set-points.

  8. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    Science.gov (United States)

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid

  9. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) Imaging in the Staging and Prognosis of Inflammatory Breast Cancer

    International Nuclear Information System (INIS)

    Alberini, J.L.; Wartski, M.; Gontier, E.; Madar, O.; Pecking, A.P.; Lerebours, F.; Fourme, E.; Le Stanc, E.; Cherel, P.; Alberini, J.L.

    2009-01-01

    Background: To prospectively assess fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) staging and prognosis value in patients with suspected inflammatory breast cancer (IBC). Methods: Sixty-two women (mean age 50.7 ± 11.4 years) presenting with unilateral inflammatory breast tumors (59 invasive carcinomas; 3 mastitis) underwent a PET/CT scan before biopsy. Results: PET/CT scan was positive for the primary malignant tumor in 100% and false positive in 2 of 3 benign mastitis. In 59 IBC patients, FDG nodal foci were detected in axillary (90%; n = 53) and extra-axillary areas (56%; n = 33) ipsilateral to the cancer. Compared with clinical examination, the axillary lymph node status by PET/CT was upstaged and down staged in 35 and 5 patients, respectively. In 7 of 9 N0 patients, the axillary lymph node positivity on PET/CT was correct, as revealed by pathological post surgery assessment (not available in the 2 remaining patients). The nodal foci were compared with preoperative fine needle aspiration and/or pathological post chemotherapy findings available in 44 patients and corresponded to 38 true positive, 4 false-negative, and 2 false-positive cases. In 18 of 59 IBC patients (31%), distant lesions were found. On the basis of a univariate analysis of the first enrolled patients (n = 42), among 28 patients who showed intense tumoral uptake (standard uptake value(max)≥5), the 11 patients with distant lesions had a worse prognosis than the 17 patients without distant lesions (P =.04). Conclusions: FDG-PET/CT imaging provides additional invaluable information regarding nodal status or distant metastases in IBC patients and should be considered in the initial staging. It seems also that some prognostic information can be derived from FDG uptake characteristics. (authors)

  10. EUS – Fine- Needle Aspiration Biopsy (FNAB in the Diagnosis of Pancreatic Adenocarcinoma: A Review

    Directory of Open Access Journals (Sweden)

    Kalogeraki Alexandra

    2016-03-01

    Full Text Available Solid masses of the pancreas represent a variety of benign and malignant neoplasms of the exocrine and endocrine tissues of the pancreas. A tissue diagnosis is often required to direct therapy in the face of uncertain diagnosis or if the patient is not a surgical candidate either due to advanced disease or comorbidities. Endoscopic ultrasound (EUS is a relatively new technology that employs endoscopy and high-frequency ultrasound (US. EUS involves imaging of the pancreatic head and the uncinate from the duodenum and imaging of the body and tail from the stomach. It has been shown to be a highly sensitive method for the detection of pancreatic masses. It is superior to extracorporeal US and computed tomographic (CT scans, especially when the pancreatic tumor is smaller than 2-3 cm. Although EUS is highly sensitive in detecting pancreatic solid masses, its ability to differentiate between inflammatory masses and malignant disease is limited. Endoscopic retrograde cholangiopancreatography (ERCP brushing, CT-guided biopsies, and transabdominal ultrasound (US have been the standard nonsurgical methods for obtaining a tissue diagnosis of pancreatic lesions, but a substantial false-negative rate has been reported. Transabdominal US-guided fine-needle aspiration biopsy (US-FNAB has been used for tissue diagnosis in patients with suspected pancreatic carcinoma. It has been shown to be highly specific, with no false-positive diagnoses. With the advent of curvilinear echoendoscopes, transgastric and transduodenal EUS-FNAB of the pancreas have become a reality EUS with FNAB has revolutionized the ability to diagnose and stage cancers of the gastrointestinal tract and assess the pancreas. Gastrointestinal cancers can be looked at with EUS and their depth of penetration into the intestinal wall can be determined. Any suspicious appearing lymph nodes can be biopsied using EUS/FNAB. The pancreas is another organ that is well visualized with EUS. Abnormalities

  11. Computed tomography findings of early abdominal postoperative complications

    International Nuclear Information System (INIS)

    Zissin, R.; Osadchy, A.; Gayer, G.

    2007-01-01

    Various surgical approaches are used for different abdominal pathological conditions. Postoperative complications occur not infrequently and vary according to the type of the surgery and the clinical context. Nowadays, multidetector computed tomography (MDCT) provides superb anatomic detail and diagnostic accuracy for various intraabdominal pathological processes, even if clinically unsuspected, and it thus has become an essential diagnostic tool for evaluating postoperative insults. Other advantages of abdominal MDCT include its accessibility and its speed, which allow scanning of uncooperative, marginally stable patients. Computed tomography (CT)-guided percutaneous (PC) drainage of postoperative collections is another advantage of CT. Therefore, although CT requires transportation of a critically ill, postoperative patient, it is recommended in any suspicious clinical setting because several conditions require prompt management and a correct diagnosis is crucial. In assessing a patient for suspected postoperative complications, several points should be taken into consideration, including the relevant clinical and laboratory data, the surgical findings, the type of the surgery, the time elapsed since surgery, and the operative technique (either open laparotomy of laparoscopic procedure). (author)

  12. The Amyand's Hernia: A Rare Clinical Entity Diagnosed by Computed Tomography.

    Science.gov (United States)

    Keskin, Suat; Simşek, Cihan; Keskin, Zeynep

    2013-01-01

    Amyand's hernia, named for the first person to describe an inguinal hernia containing the vermiform appendix, is an uncommon variant of an inguinal hernia. Amyand's hernia is an extremely rare condition and is often misdiagnosed. Traditionally, these hernias have been diagnosed at surgery but are increasingly diagnosed by abdominal computed tomography (CT) scans. CT of the abdomen may help in guiding the diagnosis.

  13. Transrectal EUS-guided FNA biopsy of a presacral chordoma-report of a case and review of the literature

    Institute of Scientific and Technical Information of China (English)

    Klaus Gottlieb; Paul H Lin; David M Liu; Karl Anders

    2008-01-01

    Chordomas are rare tumors which originate from the remnants of the notochord.These tumors are locally aggressive and have a predilection for the ends of the axial skeleton.An important prerequisite for optimal management of these tumors is a correct preoperative diagnosis.The present case is the first report of the use of endoscopic ultrasound to obtain transrectal fine needle aspiration biopsy of a presacral chordoma.A review of the prior computer tomography (CT) scans allowed us to calculate the tumor volume doubling time (18.3 mo).Transrectal biopsy of chordomas is controversial,however we believe that such concerns are not justified.

  14. Radiological and cytological correlation of neoplastic lesions of the breast diagnosed by fine needle aspiration biopsy guided with ultrasound at the Hospital San Juan de Dios in the year 2009

    International Nuclear Information System (INIS)

    Madriz Meza, Wendy P.

    2011-01-01

    Mortality from breast cancer has been increased, going on to occupy the first place of the malignant neoplasms in women with a percentage increase of over 45% in 10 years. A bibliographic search demonstrates that have not been performed works that allow to establish the clinical and radiological characteristics of the lesions who have been diagnosed as mammary neoplasms by fine needle aspiration biopsy at the Hospital San Juan de Dios. A observational job, descriptive, longitudinal, retrospective is pretended to perform, to provide an instrument of guidance to the radiologist about the characteristics of alarm on a breast lesion. Female patients ascribed to the Hospital San Juan de Dios, with breast cancer diagnosed by guided fine needle puncture with echography during the year 2009 are included in the study. Data from 39 patients that fulfilled with all the inclusion criteria were presented. The data obtained were collected by reviewing of clinical records; which were found only women, who in their majority were from the province of San Jose, the most affected age group by the five-year periods has been of 45-49 years, followed by the groups between 40-44 years and 50-54 years. The greater part of cases has treated of unique injuries, almost all have been unilateral and measure the size of all the lesions was 21 mm. The injuries have been primarily in the right breast and the upper outer quadrant. The level of radiological success has been good in cases where was used the BIRADS, because it was classified with 4c or 5 to 52,4% of cases, however, it should be noted that in 17 of 39 cases were not properly categorized BIRADS. The main conclusions of this study are: women whose ages are between 45 and 55 years have been especially prone to mammary neoplasms, these lesions are found primarily in upper outer quadrants and measured more than 2 cm. The health problems generated in the patients with these diagnoses have made important to prioritize your attention once

  15. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years.

    Science.gov (United States)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong

    2017-08-01

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. • CT-guided core needle biopsy is an accurate technique for diagnosing mediastinal nodes. • The rates of complications are similar to those for pulmonary lesion biopsy. • Pneumothorax risk factors include distance from pleura to target lesion and number of visceral pleura. • Distance from pleura to target lesion is the risk factor for hemoptysis. • CT-guided core needle biopsy is an important diagnostic method for mediastinal nodes.

  16. Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.

    Science.gov (United States)

    Farley, Nathaniel E; Kennedy, Kelly; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Recent clinical studies have shown that implant placement is highly predictable with computer-generated surgical guides; however, the reliability of these guides has not been compared to that of conventional guides clinically. This study aimed to compare the accuracy of reproducing planned implant positions with computer-generated and conventional surgical guides using a split-mouth design. Ten patients received two implants each in symmetric locations. All implants were planned virtually using a software program and information from cone beam computed tomographic scans taken with scan appliances in place. Patients were randomly selected for computer-aided design/computer-assisted manufacture (CAD/CAM)-guided implant placement on their right or left side. Conventional guides were used on the contralateral side. Patients underwent operative cone beam computed tomography postoperatively. Planned and actual implant positions were compared using three-dimensional analyses capable of measuring volume overlap as well as differences in angles and coronal and apical positions. Results were compared using a mixed-model repeated-measures analysis of variance and were further analyzed using a Bartlett test for unequal variance (α = .05). Implants placed with CAD/CAM guides were closer to the planned positions in all eight categories examined. However, statistically significant differences were shown only for coronal horizontal distances. It was also shown that CAD/CAM guides had less variability than conventional guides, which was statistically significant for apical distance. Implants placed using CAD/CAM surgical guides provided greater accuracy in a lateral direction than conventional guides. In addition, CAD/CAM guides were more consistent in their deviation from the planned locations than conventional guides.

  17. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    NARCIS (Netherlands)

    Borot, Maxence; Denis de Senneville, Baudouin; Maenhout, Metha; Lagendijk, JJW; van Vulpen, Marco; Hautvast, Gilion; Binnekamp, Dirk; Moerland, Rien

    2016-01-01

    PURPOSE: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image

  18. Incorporation of 13C labeled Pinus ponderosa needle and fine root litter into soil organic matter measured by Py-GC/MS-C-IRMS

    Science.gov (United States)

    Mambelli, S.; Gleixner, G.; Dawson, T. E.; Bird, J. A.; Torn, M. S.

    2006-12-01

    Developing effective strategies for enhancing C storage in soils requires understanding the influence of plant C quality. In turn, plant C quality impacts the decay continuum between plant residue and humified, stable SOM. This remains one of the least understood aspects of soil biogeochemistry. We investigated the initial phase of incorporation of 13C labeled Pinus ponderosa needle and fine root litter into SOM. The two litter types were placed in separate microcosms in the A horizon in a temperate conifer soil. Curie-point pyrolysis-gas chromatography coupled with on-line mass spectrometry and isotope ratio mass spectrometry (Py-GC/MS-C- IRMS) were used to determine the identity and the 13C enrichment of pyrolysis products (fragments of carbohydrates, lignin, proteins and lipids). We compared the two initial litter types, needles and fine roots, to samples of the bulk soil (A horizon, < 2mm) and soil humin fraction (from chemical solubility) obtained from each microcosm 1.5y after litter addition. Pyrolysis of plant material and SOM produced 56 suitable products for isotopic analysis; of them, 15 occurred in both the litter and bulk soil, 7 in both the litter and the humin fraction and 9 in both bulk soil and the humin fraction. The pyrolysis products found in common in the plant and soil were related either to polysaccharides or were non-specific and could have originated from various precursors. The data suggest that the majority of plant inputs, both from needles or fine roots, were degraded very rapidly. In the humin fraction, the most recalcitrant pool of C in soil, with a measured turnover time of 260y (this soil), only products from the fragmentation of polysaccharides and alkyl-benzene compounds were found. Comparisons of the enrichment normalized by input level suggest little difference between the incorporation of C from needles versus fine roots into SOM. The most enriched fragments in the humin fraction were products from polysaccharides degradation

  19. Toward Transoral Peripheral Lung Access: Combining Continuum Robots and Steerable Needles.

    Science.gov (United States)

    Swaney, Philip J; Mahoney, Arthur W; Hartley, Bryan I; Remirez, Andria A; Lamers, Erik; Feins, Richard H; Alterovitz, Ron; Webster, Robert J

    2017-03-01

    Lung cancer is the most deadly form of cancer in part because of the challenges associated with accessing nodules for diagnosis and therapy. Transoral access is preferred to percutaneous access since it has a lower risk of lung collapse, yet many sites are currently unreachable transorally due to limitations with current bronchoscopic instruments. Toward this end, we present a new robotic system for image-guided trans-bronchoscopic lung access. The system uses a bronchoscope to navigate in the airway and bronchial tubes to a site near the desired target, a concentric tube robot to move through the bronchial wall and aim at the target, and a bevel-tip steerable needle with magnetic tracking to maneuver through lung tissue to the target under closed-loop control. In this work, we illustrate the workflow of our system and show accurate targeting in phantom experiments. Ex vivo porcine lung experiments show that our steerable needle can be tuned to achieve appreciable curvature in lung tissue. Lastly, we present targeting results with our system using two scenarios based on patient cases. In these experiments, phantoms were created from patient-specific computed tomography information and our system was used to target the locations of suspicious nodules, illustrating the ability of our system to reach sites that are traditionally inaccessible transorally.

  20. Creating vascular models by postprocessing computed tomography angiography images: a guide for anatomical education.

    Science.gov (United States)

    Govsa, Figen; Ozer, Mehmet Asim; Sirinturk, Suzan; Eraslan, Cenk; Alagoz, Ahmet Kemal

    2017-08-01

    A new application of teaching anatomy includes the use of computed tomography angiography (CTA) images to create clinically relevant three-dimensional (3D) printed models. The purpose of this article is to review recent innovations on the process and the application of 3D printed models as a tool for using under and post-graduate medical education. Images of aortic arch pattern received by CTA were converted into 3D images using the Google SketchUp free software and were saved in stereolithography format. Using a 3D printer (Makerbot), a model mode polylactic acid material was printed. A two-vessel left aortic arch was identified consisting of the brachiocephalic trunk and left subclavian artery. The life-like 3D models were rotated 360° in all axes in hand. The early adopters in education and clinical practices have embraced the medical imaging-guided 3D printed anatomical models for their ability to provide tactile feedback and a superior appreciation of visuospatial relationship between the anatomical structures. Printed vascular models are used to assist in preoperative planning, develop intraoperative guidance tools, and to teach patients surgical trainees in surgical practice.

  1. Effectiveness of Toyota process redesign in reducing thyroid gland fine-needle aspiration error.

    Science.gov (United States)

    Raab, Stephen S; Grzybicki, Dana Marie; Sudilovsky, Daniel; Balassanian, Ronald; Janosky, Janine E; Vrbin, Colleen M

    2006-10-01

    Our objective was to determine whether the Toyota Production System process redesign resulted in diagnostic error reduction for patients who underwent cytologic evaluation of thyroid nodules. In this longitudinal, nonconcurrent cohort study, we compared the diagnostic error frequency of a thyroid aspiration service before and after implementation of error reduction initiatives consisting of adoption of a standardized diagnostic terminology scheme and an immediate interpretation service. A total of 2,424 patients underwent aspiration. Following terminology standardization, the false-negative rate decreased from 41.8% to 19.1% (P = .006), the specimen nondiagnostic rate increased from 5.8% to 19.8% (P Toyota process change led to significantly fewer diagnostic errors for patients who underwent thyroid fine-needle aspiration.

  2. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  3. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  4. Computational adaptive optics for broadband interferometric tomography of tissues and cells

    Science.gov (United States)

    Adie, Steven G.; Mulligan, Jeffrey A.

    2016-03-01

    Adaptive optics (AO) can shape aberrated optical wavefronts to physically restore the constructive interference needed for high-resolution imaging. With access to the complex optical field, however, many functions of optical hardware can be achieved computationally, including focusing and the compensation of optical aberrations to restore the constructive interference required for diffraction-limited imaging performance. Holography, which employs interferometric detection of the complex optical field, was developed based on this connection between hardware and computational image formation, although this link has only recently been exploited for 3D tomographic imaging in scattering biological tissues. This talk will present the underlying imaging science behind computational image formation with optical coherence tomography (OCT) -- a beam-scanned version of broadband digital holography. Analogous to hardware AO (HAO), we demonstrate computational adaptive optics (CAO) and optimization of the computed pupil correction in 'sensorless mode' (Zernike polynomial corrections with feedback from image metrics) or with the use of 'guide-stars' in the sample. We discuss the concept of an 'isotomic volume' as the volumetric extension of the 'isoplanatic patch' introduced in astronomical AO. Recent CAO results and ongoing work is highlighted to point to the potential biomedical impact of computed broadband interferometric tomography. We also discuss the advantages and disadvantages of HAO vs. CAO for the effective shaping of optical wavefronts, and highlight opportunities for hybrid approaches that synergistically combine the unique advantages of hardware and computational methods for rapid volumetric tomography with cellular resolution.

  5. Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases

    International Nuclear Information System (INIS)

    Rimondi, Eugenio; Rossi, Giuseppe; Bartalena, Tommaso; Ciminari, Rosanna; Alberghini, Marco; Ruggieri, Pietro; Errani, Costantino; Angelini, Andrea; Calabro, Teresa; Abati, Caterina Novella; Balladelli, Alba; Tranfaglia, Cristina; Mavrogenis, Andreas F.; Vanel, Daniel; Mercuri, Mario

    2011-01-01

    Introduction: Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications. Materials and methods: We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors' institution. The results obtained are subject of this paper. Results: In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome. Conclusion: This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.

  6. Unique migration of a dental needle into the parapharyngeal space: successful removal by an intraoral approach and simulation for tracking visibility in X-ray fluoroscopy.

    Science.gov (United States)

    Okumura, Yuri; Hidaka, Hiroshi; Seiji, Kazumasa; Nomura, Kazuhiro; Takata, Yusuke; Suzuki, Takahiro; Katori, Yukio

    2015-02-01

    The first objective was to describe a novel case of migration of a broken dental needle into the parapharyngeal space. The second was to address the importance of simulation elucidating visualization of such a thin needle under X-ray fluoroscopy. Clinical case records (including computed tomography [CT] and surgical approaches) were reviewed, and a simulation experiment using a head phantom was conducted using the same settings applied intraoperatively. A 36-year-old man was referred after failure to locate a broken 31-G dental needle. Computed tomography revealed migration of the needle into the parapharyngeal space. Intraoperative X-ray fluoroscopy failed to identify the needle, so a steel wire was applied as a reference during X-ray to locate the foreign body. The needle was successfully removed using an intraoral approach with tonsillectomy under surgical microscopy. The simulation showed that the dental needle was able to be identified only after applying an appropriate compensating filter, contrasting with the steel wire. Meticulous preoperative simulation regarding visual identification of dental needle foreign bodies is mandatory. Intraoperative radiography and an intraoral approach with tonsillectomy under surgical microscopy offer benefits for accessing the parapharyngeal space, specifically for cases medial to the great vessels. © The Author(s) 2014.

  7. Greater physician involvement improves coding outcomes in endobronchial ultrasound-guided transbronchial needle aspiration procedures.

    Science.gov (United States)

    Pillai, Anilkumar; Medford, Andrew R L

    2013-01-01

    Correct coding is essential for accurate reimbursement for clinical activity. Published data confirm that significant aberrations in coding occur, leading to considerable financial inaccuracies especially in interventional procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Previous data reported a 15% coding error for EBUS-TBNA in a U.K. service. We hypothesised that greater physician involvement with coders would reduce EBUS-TBNA coding errors and financial disparity. The study was done as a prospective cohort study in the tertiary EBUS-TBNA service in Bristol. 165 consecutive patients between October 2009 and March 2012 underwent EBUS-TBNA for evaluation of unexplained mediastinal adenopathy on computed tomography. The chief coder was prospectively electronically informed of all procedures and cross-checked on a prospective database and by Trust Informatics. Cost and coding analysis was performed using the 2010-2011 tariffs. All 165 procedures (100%) were coded correctly as verified by Trust Informatics. This compares favourably with the 14.4% coding inaccuracy rate for EBUS-TBNA in a previous U.K. prospective cohort study [odds ratio 201.1 (1.1-357.5), p = 0.006]. Projected income loss was GBP 40,000 per year in the previous study, compared to a GBP 492,195 income here with no coding-attributable loss in revenue. Greater physician engagement with coders prevents coding errors and financial losses which can be significant especially in interventional specialties. The intervention can be as cheap, quick and simple as a prospective email to the coding team with cross-checks by Trust Informatics and against a procedural database. We suggest that all specialties should engage more with their coders using such a simple intervention to prevent revenue losses. Copyright © 2013 S. Karger AG, Basel.

  8. {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) Imaging in the Staging and Prognosis of Inflammatory Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Alberini, J.L.; Wartski, M.; Gontier, E.; Madar, O.; Pecking, A.P. [Nuclear Medicine Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Lerebours, F. [Oncology Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Fourme, E. [Biostatistics Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Le Stanc, E. [Nuclear Medicine Department, Foch Hospital, Suresnes (France); Cherel, P. [Radiology Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Alberini, J.L. [School of Medicine, Versailles Saint-Quentin University (France)

    2009-07-01

    Background: To prospectively assess fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) staging and prognosis value in patients with suspected inflammatory breast cancer (IBC). Methods: Sixty-two women (mean age 50.7 {+-} 11.4 years) presenting with unilateral inflammatory breast tumors (59 invasive carcinomas; 3 mastitis) underwent a PET/CT scan before biopsy. Results: PET/CT scan was positive for the primary malignant tumor in 100% and false positive in 2 of 3 benign mastitis. In 59 IBC patients, FDG nodal foci were detected in axillary (90%; n = 53) and extra-axillary areas (56%; n = 33) ipsilateral to the cancer. Compared with clinical examination, the axillary lymph node status by PET/CT was upstaged and down staged in 35 and 5 patients, respectively. In 7 of 9 N0 patients, the axillary lymph node positivity on PET/CT was correct, as revealed by pathological post surgery assessment (not available in the 2 remaining patients). The nodal foci were compared with preoperative fine needle aspiration and/or pathological post chemotherapy findings available in 44 patients and corresponded to 38 true positive, 4 false-negative, and 2 false-positive cases. In 18 of 59 IBC patients (31%), distant lesions were found. On the basis of a univariate analysis of the first enrolled patients (n = 42), among 28 patients who showed intense tumoral uptake (standard uptake value(max){>=}5), the 11 patients with distant lesions had a worse prognosis than the 17 patients without distant lesions (P =.04). Conclusions: FDG-PET/CT imaging provides additional invaluable information regarding nodal status or distant metastases in IBC patients and should be considered in the initial staging. It seems also that some prognostic information can be derived from FDG uptake characteristics. (authors)

  9. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  10. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    Science.gov (United States)

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  11. Carbon fibre and nitinol needles for MRI-guided interventions: First in vitro and in vivo application

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Christoph, E-mail: Christoph.thomas@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Wojtczyk, Hanne [Section of Experimental Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Rempp, Hansjoerg; Clasen, Stephan; Horger, Marius [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Lassberg, Christoph von [Department of Sports Medicine, University of Tuebingen, Silcherstrasse 5, 72076 Tuebingen (Germany); Fritz, Jan [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 600 North Wolfe Street, Baltimore, MD 21287 (United States); Claussen, Claus D. [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Pereira, Philippe L. [Department of Radiology, Minimally Invasive Therapies and Nuclearmedicine, SLK-Kliniken Heilbronn GmbH, Am Gesundbrunnen 20-26, 74078 Heilbronn (Germany)

    2011-09-15

    Objective: To assess the artefact properties of a MR-compatible carbon fibre needle with a nitinol mandrin in vitro and to report first clinical experiences. Materials and methods: In vitro, the carbon fibre/nitinol needle was imaged at different angles against the main magnetic field (1.5 T open bore magnet). A gradient echo MR fluoroscopy sequence (GRE: TR 9.3 ms, TE 3.12 ms, bandwidth 200 Hz/pixel, flip-angle 12{sup o}) and a fast turbo spin echo sequence (FSE: TR 412 ms, TE 9.7 ms, bandwidth 200 Hz/pixel, flip-angle 150{sup o}) were used. Artefact width, needle intensity contrast and needle tip location errors were assessed. In vivo, lumbar periradicular corticosteroid injections and one sclerotherapy were performed with carbon fibre needles (10 procedures) and with titanium alloy needles (2 procedures). The artefact sizes and contrasts were measured. Results: In vitro, artefact diameters of the carbon fibre needle ranged from 3.3 to 4.6 mm, contrasts from 0.11 to 0.52, with larger artefact contrasts and widths with the GRE sequence. Needle tip location errors of -2.1 to -2.8 mm were observed. Decreasing angles to the main field lead to smaller artefacts. In vivo, the carbon fibre/nitinol needle produced smaller artefacts (mean width FSE/GRE: 2.8 mm/4.6 mm) with lower contrast (0.30-0.42) than the titanium alloy needle (mean width FSE/GRE: 4.1 mm/7.5 mm, contrast 0.60-0.73). Conclusions: The carbon fibre/nitinol needle is useful for performing MR-guided interventions at 1.5 T, producing more subtle artefacts than a titanium alloy needle, but with an incomplete depiction and thus inaccurate localization of the needle tip.

  12. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.

    Science.gov (United States)

    Ersoy, Ahmet Ersan; Turkyilmaz, Ilser; Ozan, Oguz; McGlumphy, Edwin A

    2008-08-01

    Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees+/-2.36 degrees, whereas the mean linear deviation was 1.22+/-0.85 mm at the implant neck and 1.51+/-1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees+/-0.36 degrees, 1.04+/-0.56 mm, and 1.57+/-0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees+/-0.31 degrees, 1.42+/-1.05 mm, and 1.44+/-1.03 mm, respectively. SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.

  13. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  14. Radiographic and computed tomography monitoring of a fractured needle fragment in the mandibular branch

    International Nuclear Information System (INIS)

    De Oliveira e Britto Villalobos, Maria Isabel; Leite, Thaisa Cristina Gomes Ferreira; Barra, Samila Goncalves; Da Cunha Werneche, Daniela Teresa Pinto; Manzi, Flavio Ricardo; E Alves Cardoso, Claudia Assuncao

    2017-01-01

    Some complications can arise with the usage of local anesthesia for dental procedures, including the fracture of needles in the patient. This is a rare incident, usually caused by the patient's sudden movements during anesthetic block. Its complications are not common, but can include pain, trismus, inflammation in the region, difficulty in swallowing, and migration of the object, which is the least common but has the ability to cause more serious damage to the patient. This report describes a case in which, after the fracture of the anesthetic needle used during alveolar nerve block for exodontia of the left mandibular third molar, the fragment moved significantly in the first 2 months, before stabilizing after the third month of radiographic monitoring

  15. Radiographic and computed tomography monitoring of a fractured needle fragment in the mandibular branch

    Energy Technology Data Exchange (ETDEWEB)

    De Oliveira e Britto Villalobos, Maria Isabel; Leite, Thaisa Cristina Gomes Ferreira; Barra, Samila Goncalves; Da Cunha Werneche, Daniela Teresa Pinto; Manzi, Flavio Ricardo; E Alves Cardoso, Claudia Assuncao [Dept. of Dentistry, Pontificial Catholic University of Minas Gerais, Belo Horizonte (Brazil)

    2017-03-15

    Some complications can arise with the usage of local anesthesia for dental procedures, including the fracture of needles in the patient. This is a rare incident, usually caused by the patient's sudden movements during anesthetic block. Its complications are not common, but can include pain, trismus, inflammation in the region, difficulty in swallowing, and migration of the object, which is the least common but has the ability to cause more serious damage to the patient. This report describes a case in which, after the fracture of the anesthetic needle used during alveolar nerve block for exodontia of the left mandibular third molar, the fragment moved significantly in the first 2 months, before stabilizing after the third month of radiographic monitoring.

  16. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  17. [Discussion on needling sensation, arrival of qi and needling response (Deqi)].

    Science.gov (United States)

    Zhang, Fang; Wang, Hong-Du

    2012-12-01

    The current appointed teaching material of Science of Acupuncture and Moxibustion holds that there is no difference among the needling sensation, arrival of qi and needling response. However, the author has a different understanding. Therefore, Neijing (Internal Classic), its annotation, exposition and understandings of ancient and modern famous experts are cited to analyze their meanings. And the result indicates that the needling sensation is subjective feelings and perceived responses of doctors and patients. Arrival of qi is the healing process of the organ through activating the anti-pathogenic qi to expel the pathogens. The needling response is the final aim of acupuncture therapy. Thus, the meaning of needling sensation, arrival of qi, and needling response are different. And an accurate understanding can better guide acupuncture treatment.

  18. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  19. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  20. Aspergillus thyroiditis: first antemortem case diagnosed by fine-needle aspiration culture in a pediatric stem cell transplant patient.

    Science.gov (United States)

    Badawy, S M; Becktell, K D; Muller, W J; Schneiderman, J

    2015-12-01

    Aspergillus thyroiditis (AT) has historically been considered a postmortem diagnosis in immunocompromised patients; most have disseminated disease. This report summarizes the clinical challenge of diagnosing AT. It also highlights the value of the early use of thyroid fine-needle aspiration culture and the need for a high index of suspicion to reach the final diagnosis before disease dissemination. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.