WorldWideScience

Sample records for computed tomography-guided biopsy

  1. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  2. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  3. Computer tomography guided lung biopsy using interactive breath-hold control

    DEFF Research Database (Denmark)

    Ashraf, Haseem; Krag-Andersen, Shella; Naqibullah, Matiullah

    2017-01-01

    Background: Interactive breath-hold control (IBC) may improve the accuracy and decrease the complication rate of computed tomography (CT)-guided lung biopsy, but this presumption has not been proven in a randomized study. Methods: Patients admitted for CT-guided lung biopsy were randomized...

  4. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens

    2002-01-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  5. Computed tomography-guided core-needle biopsy of lung lesions: an oncology center experience

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; Fonte, Alexandre Calabria da; Chojniak, Rubens, E-mail: marcosduarte@yahoo.com.b [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Radiology and Imaging Diagnosis; Andrade, Marcony Queiroz de [Hospital Alianca, Salvador, BA (Brazil); Gross, Jefferson Luiz [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Chest Surgery

    2011-03-15

    Objective: The present study is aimed at describing the experience of an oncology center with computed tomography guided core-needle biopsy of pulmonary lesions. Materials and Methods: Retrospective analysis of 97 computed tomography-guided core-needle biopsy of pulmonary lesions performed in the period between 1996 and 2004 in a Brazilian reference oncology center (Hospital do Cancer - A.C. Camargo). Information regarding material appropriateness and the specific diagnoses were collected and analyzed. Results: Among 97 lung biopsies, 94 (96.9%) supplied appropriate specimens for histological analyses, with 71 (73.2%) cases being diagnosed as malignant lesions and 23 (23.7%) diagnosed as benign lesions. Specimens were inappropriate for analysis in three cases. The frequency of specific diagnosis was 83 (85.6%) cases, with high rates for both malignant lesions with 63 (88.7%) cases and benign lesions with 20 (86.7%). As regards complications, a total of 12 cases were observed as follows: 7 (7.2%) cases of hematoma, 3 (3.1%) cases of pneumothorax and 2 (2.1%) cases of hemoptysis. Conclusion: Computed tomography-guided core needle biopsy of lung lesions demonstrated high rates of material appropriateness and diagnostic specificity, and low rates of complications in the present study. (author)

  6. Uncommon primary tumors of the orbit diagnosed by computed tomography-guided core needle biopsy: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Matushita Junior, Joao Paulo Kawaoka; Bitencourt, Almir Galvao Vieira; Amoedo, Mauricio Kauark; Barbosa, Paula Nicole Vieira; Chojniak, Rubens, E-mail: almirgvb@yahoo.com.br [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil). Dept. de Imagem; Neves, Flavia Branco Cerqueira Serra [Hospital do Servidor Publico Estadual, Sao Paulo, SP (Brazil). Div. de Oftalmologia

    2014-11-15

    Computed tomography-guided percutaneous biopsy is a safe and effective alternative method for evaluating selected intra-orbital lesions where the preoperative diagnosis is important for the therapeutic planning. The authors describe two cases of patients with uncommon primary orbital tumors whose diagnosis was obtained by means of computed tomography-guided core needle biopsy, with emphasis on the technical aspects of the procedure. (author)

  7. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  8. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  9. Computed tomography-guided percutaneous core needle biopsy of deep seated bone lesions in two dogs

    International Nuclear Information System (INIS)

    Mori, T.; Sakaida, M.; Yamada, M.; Akiyama, H.; Takai, Y.; Sakai, H.; Maruo, K.

    2006-01-01

    Computed Tomography (CT)-guided percutaneous core needle biopsies were undertaken for the diagnosis of osteosarcoma in the pelvis (case 1) and myeloma (case 2) in the seventh lumber vertebra which were difficult to targeted by palpation, ultrasound or fluoroscopy. In both cases, enough tissue for pathological diagnosis were obtained without any complication. CT-guided biopsy was thought to be a safe, easy and effective technique for the evaluation of the deep seated bone lesion

  10. Fluoroscopy-Guided Percutaneous Lung Biopsy: A Valuable Alternative to Computed Tomography

    International Nuclear Information System (INIS)

    Kurban, L.A.; Gomersall, L.; Weir, J.; Wade, P.

    2008-01-01

    Background: Computed tomography (CT) fluoroscopy nowadays is the most preferred method of guidance to perform percutaneous lung biopsy of pulmonary masses. Conventional fluoroscopy is an increasingly forgotten technique that still can be used to perform lung biopsies, with many advantages. Purpose: To compare the accuracy, safety, and effective dose (ED) of conventional fluoroscopy-guided needle lung biopsy (FNLB) with CT-guided needle lung biopsy procedures (CTNLB) reported in the literature. Material and Methods: 100 consecutive patients who underwent FNLB were reviewed retrospectively. Using the final histological diagnoses and the clinical and radiological course of the disease as references, the accuracy and sensitivity of FNLB were calculated. The complication rates of FNLB were assessed. Using computer software (XDOSE), the ED was calculated. The accuracy, complication rates, and the ED of FNLB were compared with CTNLB reported in the literature. Results: The overall accuracy rate and sensitivity of FNLB were both 87%, which are comparable to the range of accuracies reported in the literature for CTNLB (74-97%). The complication rates of FNLB were also comparable to the complication rates reported for CTNLB. The commonest complication was pneumothorax, at a rate of 25%. The ED of FNLB was small, significantly lower than reported in the literature for CT-guided procedures. The mean ED of FNLB was 0.029 mSv, which is approximately equivalent to one chest X-ray. Conclusion: Conventional fluoroscopy is an accurate, safe, and low-dose alternative modality to CT to obtain an image-guided histological diagnosis of pulmonary lesions

  11. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection; Biopsia percutanea de massas pancreaticas guiada por tomografia computadorizada com pneumodisseccao

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens, E-mail: chiangjengtyng@gmail.com [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Imagem; Coimbra, Felipe Jose Fernandez [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Cirurgia Abdominal

    2013-05-15

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  12. Computed tomography-guided needle biopsy of lung lesions in fourteen cats and dogs

    International Nuclear Information System (INIS)

    Yoshida, K.; Mori, T.; Yamada, M.; Sakaida, M.; Yonemaru, K.; Murakami, M.; Sakai, H.; Maruo, K.

    2007-01-01

    Computed tomography (CT)-guided fine-needle aspirates (FNA) or core biopsies of lung lesions were performed in nine dogs and five cats. A clinical diagnosis was obtained in twelve of fourteen animals (85%), namely 80% FNA and 100% core biopsies. Eight animals had other mass (es) apart from the lung, and five were diagnosed to metastases. In only one case, the lung mass was histopathologically diagnosed as a malignant primary tumor. Iatrogenic complications through the lung biopsies were noted in four animals, and three showed mild pneumothorax on CT images and one was bleeding from the needle. However, between fifteen and thirty minutes after the biopsy, no animal indicated signs of pneumothorax or hemorrhage

  13. Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique

    International Nuclear Information System (INIS)

    Motamedi, Kambiz; Levine, Benjamin D.; Seeger, Leanne L.; McNitt-Gray, Michael F.

    2014-01-01

    To evaluate the success rate of a low-dose (50 % mAs reduction) computed tomography (CT) biopsy technique. This protocol was adopted based on other successful reduced-CT radiation dose protocols in our department, which were implemented in conjunction with quality improvement projects. The technique included a scout view and initial localizing scan with standard dose. Additional scans obtained for further guidance or needle adjustment were acquired by reducing the tube current-time product (mAs) by 50 %. The radiology billing data were searched for CT-guided musculoskeletal procedures performed over a period of 8 months following the initial implementation of the protocol. These were reviewed for the type of procedure and compliance with the implemented protocol. The compliant CT-guided biopsy cases were then retrospectively reviewed for patient demographics, tumor pathology, and lesion size. Pathology results were compared to the ultimate diagnoses and were categorized as diagnostic, accurate, or successful. Of 92 CT-guided procedures performed during this period, two were excluded as they were not biopsies (one joint injection and one drainage), 19 were excluded due to non-compliance (operators neglected to follow the protocol), and four were excluded due to lack of available follow-up in our electronic medical records. A total of 67 compliant biopsies were performed in 63 patients (two had two biopsies, and one had three biopsies). There were 32 males and 31 females with an average age of 50 (range, 15-84 years). Of the 67 biopsies, five were non-diagnostic and inaccurate and thus unsuccessful (7 %); five were diagnostic but inaccurate and thus unsuccessful (7 %); 57 were diagnostic and accurate thus successful (85 %). These results were comparable with results published in the radiology literature. The success rate of CT-guided biopsies using a low-dose protocol is comparable to published rates for conventional dose biopsies. The implemented low-dose protocol

  14. Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique

    Energy Technology Data Exchange (ETDEWEB)

    Motamedi, Kambiz; Levine, Benjamin D.; Seeger, Leanne L.; McNitt-Gray, Michael F. [UCLA Health System, Radiology, Los Angeles, CA (United States)

    2014-11-15

    To evaluate the success rate of a low-dose (50 % mAs reduction) computed tomography (CT) biopsy technique. This protocol was adopted based on other successful reduced-CT radiation dose protocols in our department, which were implemented in conjunction with quality improvement projects. The technique included a scout view and initial localizing scan with standard dose. Additional scans obtained for further guidance or needle adjustment were acquired by reducing the tube current-time product (mAs) by 50 %. The radiology billing data were searched for CT-guided musculoskeletal procedures performed over a period of 8 months following the initial implementation of the protocol. These were reviewed for the type of procedure and compliance with the implemented protocol. The compliant CT-guided biopsy cases were then retrospectively reviewed for patient demographics, tumor pathology, and lesion size. Pathology results were compared to the ultimate diagnoses and were categorized as diagnostic, accurate, or successful. Of 92 CT-guided procedures performed during this period, two were excluded as they were not biopsies (one joint injection and one drainage), 19 were excluded due to non-compliance (operators neglected to follow the protocol), and four were excluded due to lack of available follow-up in our electronic medical records. A total of 67 compliant biopsies were performed in 63 patients (two had two biopsies, and one had three biopsies). There were 32 males and 31 females with an average age of 50 (range, 15-84 years). Of the 67 biopsies, five were non-diagnostic and inaccurate and thus unsuccessful (7 %); five were diagnostic but inaccurate and thus unsuccessful (7 %); 57 were diagnostic and accurate thus successful (85 %). These results were comparable with results published in the radiology literature. The success rate of CT-guided biopsies using a low-dose protocol is comparable to published rates for conventional dose biopsies. The implemented low-dose protocol

  15. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    International Nuclear Information System (INIS)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens

    2014-01-01

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  16. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    Energy Technology Data Exchange (ETDEWEB)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens, E-mail: macellomaciel@me.com [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil)

    2014-09-15

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  17. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  18. Cone-beam computed tomography fusion and navigation for real-time positron emission tomography-guided biopsies and ablations: a feasibility study.

    Science.gov (United States)

    Abi-Jaoudeh, Nadine; Mielekamp, Peter; Noordhoek, Niels; Venkatesan, Aradhana M; Millo, Corina; Radaelli, Alessandro; Carelsen, Bart; Wood, Bradford J

    2012-06-01

    To describe a novel technique for multimodality positron emission tomography (PET) fusion-guided interventions that combines cone-beam computed tomography (CT) with PET/CT before the procedure. Subjects were selected among patients scheduled for a biopsy or ablation procedure. The lesions were not visible with conventional imaging methods or did not have uniform uptake on PET. Clinical success was defined by adequate histopathologic specimens for molecular profiling or diagnosis and by lack of enhancement on follow-up imaging for ablation procedures. Time to target (time elapsed between the completion of the initial cone-beam CT scan and first tissue sample or treatment), total procedure time (time from the moment the patient was on the table until the patient was off the table), and number of times the needle was repositioned were recorded. Seven patients underwent eight procedures (two ablations and six biopsies). Registration and procedures were completed successfully in all cases. Clinical success was achieved in all biopsy procedures and in one of the two ablation procedures. The needle was repositioned once in one biopsy procedure only. On average, the time to target was 38 minutes (range 13-54 min). Total procedure time was 95 minutes (range 51-240 min, which includes composite ablation). On average, fluoroscopy time was 2.5 minutes (range 1.3-6.2 min). An integrated cone-beam CT software platform can enable PET-guided biopsies and ablation procedures without the need for additional specialized hardware. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  19. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  20. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  1. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy. CT‑guided percutaneous ...

  2. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  3. A Comparison of Endoscopic Ultrasound Guided Biopsy and Positron Emission Tomography with Integrated Computed Tomography in Lung Cancer Staging

    DEFF Research Database (Denmark)

    Larsen, Stine Schmidt; Vilmann, P; Krasnik, K

    2009-01-01

    BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...... had both procedures performed. PATIENTS AND METHODS: 27 patients considered to be potential candidates for resection of NSCLC underwent PET/CT and EUS-FNA. Diagnoses were confirmed either by open thoracotomy, mediastinoscopy or clinical follow-up. Advanced lung cancer was defined as tumour...

  4. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy.

  5. Computed Tomography-Guided Core-Needle Biopsy Specimens Demonstrate Epidermal Growth Factor Receptor Mutations in Patients with Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Chen, C.M.; Chang, J.W.C.; Cheung, Y.C.; Lin, G.; Hsieh, J.J.; Hsu, T.; Huang, S.F.

    2008-01-01

    Background: Target therapy with a new class of epidermal growth factor receptor (EGFR) inhibitors shows improved clinical response in EGFR gene-mutated lung cancers. Purpose: To evaluate the use of computed tomography (CT)-guided core-needle biopsy specimens for the assessment of EGFR gene mutation in non-small-cell lung cancer (NSCLC). Material and Methods: Seventeen (nine males, eight females) patients with advanced NSCLC were enrolled in this study. All patients underwent CT-guided core-needle biopsy of the lung tumor prior to treatment with the EGFR inhibitor gefitinib. There were no life-threatening complications of biopsy. The specimens were sent fresh-frozen for EGFR mutation analysis and histopathological study. Results: There were 12 (70.6%) EGFR gene mutants and five (29.4%) nonmutants. The objective response rate to gefitinib therapy was 73.3% (11 of 15 patients), with 91.7% (11 of 12 mutants) for the mutant group and 0% for the nonmutant group. Conclusion: CT-guided core-needle biopsy of advanced NSCLC enables the acquisition of sufficient tissue for EGFR gene mutation analysis

  6. Magnetic-resonance-guided biopsy of focal liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ethan A. [University of Michigan Health System, Section of Pediatric Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Grove, Jason J. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Der Spek, Abraham F.L.V. [University of Michigan Health System, Department of Anesthesiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Jarboe, Marcus D. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Section of Pediatric Surgery, C.S. Mott Children' s Hospital, Department of Surgery, Ann Arbor, MI (United States)

    2017-05-15

    Image-guided biopsy techniques are widely used in clinical practice. Commonly used methods employ either ultrasound (US) or computed tomography (CT) for image guidance. In certain patients, US or CT guidance may be suboptimal, or even impossible, because of artifacts, suboptimal lesion visualization, or both. We recently began performing magnetic resonance (MR)-guided biopsy of focal liver lesions in select pediatric patients with lesions that are not well visualized by US or CT. This report describes our experience performing MR-guided biopsy of focal liver lesions, with case examples to illustrate innovative techniques and novel aspects of these procedures. (orig.)

  7. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  8. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  9. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  10. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  11. Improving CT-guided transthoracic biopsy of mediastinal lesions by diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; TyngI, Chiang Cheng; Bitencourt, Almir Galvao Vieira; Gross, Jefferson Luiz; Zurstrassen, Charles Edouard, E-mail: marcosduarte500@gmail.com [AC Camargo Cancer Center, Sao Paulo, SP (Brazil); Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), RS (Brazil). Dept. de Radiologia; Benveniste, Marcelo Felipe Kuperman; Odisio, Bruno Calazans [University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), Petropolis, RJ (Brazil)

    2014-11-15

    Objectives: to evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions. Methods: eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion. Results: in all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6–1.1]610{sup -3} mm{sup 2}/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymoma s. Conclusion: functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques. (author)

  12. Feasibility of computed tomography-guided core needle biopsy in producing state-of-the-art clinical management in Chinese lung cancer.

    Science.gov (United States)

    Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long

    2014-03-01

    A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients.

  13. Computed tomography-guided needle aspiration and biopsy of pulmonary lesions - A single-center experience in 1000 patients

    Energy Technology Data Exchange (ETDEWEB)

    Poulou, Loukia S.; Tsagouli, Paraskevi; Thanos, Loukas [Dept. of Medical Imaging and Interventional Radiology, General Hospital of Chest Diseases ' Sotiria' , Athens (Greece)], e-mail: ploukia@hotmail.com; Ziakas, Panayiotis D. [Program of Outcomes Research, Div. of Infectious Diseases, Warren Alpert Medical School, Brown Univ., RI, and Div. of Infectious Diseases, Rhode Island Hospital, Rhode Island (United States); Politi, Dimitra [Dept. of Cythopathology, General Hospital of Chest Diseases ' Sotiria' Athens (Greece); Trigidou, Rodoula [Dept. of Pathology, General Hospital of Chest Diseases ' Sotiria' Athens (Greece)

    2013-07-15

    Background: Computed tomography (CT)-guided fine needle aspiration (FNA) and biopsies are well-established, minimally invasive diagnostic tools for pulmonary lesions. Purpose: To analyze retrospectively the results of 1000 consecutive lung CT-guided FNA and/or core needle biopsies (CNB), the main outcome measures being diagnostic yield, and complication rates. Material and Methods: Patients considered eligible were those referred to our department for lung lesions. The choice of FNA, CNB, or both was based upon the radiologist's judgment. Diagnostic yield was defined as the probability of having a definite result by cytology/histology. Results: The study included 733 male patients and 267 female patients, with a mean (SD) age of 66.4 (11.4) years. The mean (SD) lesion size was 3.7 (2.4) cm in maximal diameter. Six hundred and forty-one (64%) patients underwent an FNA procedure, 245 (25%) a CNB, and 114 (11%) had been subjected to both. The diagnostic yield was 960/994 (96.6%); this decreased significantly with the use of CNB only (odds ratio [OR] 0.32; 95% CI 0.12 - 0.88; P = 0.03), while it increased with lesion size (OR 1.35; 95% CI 1.03 - 1.79; P = 0.03 per cm increase). In 506 patients (52.7%), a malignant process was diagnosed by cytopathology/histology. The complication rate reached 97/1000 (9.7%); complications included: hemorrhage, 62 (6.2%); pneumothorax, 28 (2.8%); hemorrhage and pneumothorax, 5 (0.5%); and hemoptysis, 2 (0.2%). It was not significantly affected by the type of procedure or localization of the lesion. The overall risk for complications was three times higher for lesions <4 cm (OR 3.26; 95% CI 1.96 - 5.42; P < 0.001). Conclusion: CT-guided lung biopsy has a high diagnostic yield using FNA, CNB, or both. The CNB procedure alone will not suffice. Complication rates were acceptable and correlated inversely with lesion size, not localization or type of procedure.

  14. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    Science.gov (United States)

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  15. Image-guided biopsy in patients with suspected ovarian carcinoma: a safe and effective technique?

    International Nuclear Information System (INIS)

    Griffin, Nyree; Grant, Lee A.; Freeman, Susan J.; Berman, Laurence H.; Sala, Evis; Jimenez-Linan, Mercedes; Earl, Helena; Ahmed, Ahmed Ashour; Crawford, Robin; Brenton, James

    2009-01-01

    In patients with suspected advanced ovarian carcinoma, a precise histological diagnosis is required before commencing neo-adjuvant chemotherapy. This study aims to determine the diagnostic accuracy and complication rate of percutaneous biopsies performed under ultrasound or computed tomography guidance. Between 2002 to 2007, 60 consecutive image-guided percutaneous biopsies were performed in patients with suspected ovarian cancer. The following variables were recorded: tissue biopsied, imaging technique, experience of operator, biopsy needle gauge, number of passes, complications, and final histology. Forty-seven patients had omental biopsies, 12 pelvic mass biopsies, and 1 para-aortic lymph node biopsy. Thirty-five biopsies were performed under ultrasound, 25 under computed tomography guidance. Biopsy needle gauges ranged from 14-20 swg with two to five passes for each patient. There were no complications. Histology was obtained in 52 (87%) patients. Percutaneous image-guided biopsy of peritoneal disease or pelvic mass is safe with high diagnostic accuracy. The large-gauge biopsy needle is as safe as the small gauge needle, but has the added value of obtaining tissue samples for immunohistochemistry and genomic studies. (orig.)

  16. Diagnostic yield and complications of transthoracic computed tomography-guided biopsies

    DEFF Research Database (Denmark)

    Vagn-Hansen, Chris Aksel; Pedersen, Malene Roland Vils; Rafaelsen, Søren Rafael

    2016-01-01

    , the tissue material was found to be sufficient. In 32% of the biopsies, a complication arose, mostly pneumothorax (30%), but chest drainage was needed in only 15% of the 520 cases. Patients with more than ten cigarette pack-years had a complication risk that was twice as high at that of patients with fewer...... packyears. We found that the risk of pneumothorax increased the further the lesion was from the skin surface, the smaller the lesions were and when the patient was biopsied in a lateral position. We also found a higher risk of complications in females than in males. CONCLUSIONS: CT-guided biopsy...... is an excellent tool for analysing pulmonary lesions. The present study clearly shows that the risk of developing a pneumothorax is significantly increased among smokers and former smokers with more than ten pack-years....

  17. Comparisons of Positron Emission Tomography/Computed Tomography and Ultrasound Imaging for Detection of Internal Mammary Lymph Node Metastases in Patients With Breast Cancer and Pathologic Correlation by Ultrasound-Guided Biopsy Procedures.

    Science.gov (United States)

    An, Yeong Yi; Kim, Sung Hun; Kang, Bong Joo; Lee, Ah Won

    2015-08-01

    To compare the diagnostic performance of [(18)F]fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and ultrasound imaging (US) with pathologic results obtained by US-guided biopsy and to evaluate the role of US in detecting internal mammary lymph node (LN) metastases in patients with breast cancer. Between January 2008 and December 2012, 37 patients with breast cancer (median age, 51.4 years; range, 40-79 years) underwent US-guided biopsy for suspected internal mammary LN metastases. Medical records, radiologic images, and reports were reviewed and correlated with pathologic results. The positive internal mammary LN metastasis rate was 78.4%. All biopsies were performed safely without major complications. Only 8.1% of obtained samples were unsatisfactory. There were statistically significant differences in lesion size (P = .0002), standardized uptake value on PET/CT (P = .0015), biopsy methods (P = .002), and specimen adequacy (P = .007) between metastatic and benign groups. Of the clinical factorsreviewed, only concurrent distant metastasis was correlated with internal mammary LN metastasis (P< .0001). Sensitivities for detecting internal mammary LN metastases were 76.7%, 96.7%, and 92.9% for initial US examinations, initial US combined with second-look US for initially missed cases, and PET/CT, respectively (P= .017). In a subgroup analysis, the only significant difference found was in sensitivities between initial and combined US (P = .019). In a receiver operating characteristic curve analysis, the area under the curve for PET/CT using standardized uptake criteria (0.87) was higher than that for US using size criteria (0.83); however, this difference was not significant. Although PET/CT is the best noninvasive method for evaluating internal mammary LN metastases, US is also useful if internal mammary LN evaluation is routine during standard US surveillance of patients with breast cancer. Additionally, US-guided biopsies could be

  18. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  19. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  20. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  1. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  2. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  3. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  4. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  5. CT-guided biopsies and drainage; CT-gesteuerte Punktionen und Drainagen

    Energy Technology Data Exchange (ETDEWEB)

    Scheppers, I.; Wollschlaeger, D. [Staedtisches Klinikum Karlsruhe gGmbH, Zentralinstitut fuer Bildgebende Diagnostik, Karlsruhe (Germany)

    2011-11-15

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [German] Infolge der Durchfuehrung von bildgesteuerten Biopsien solider Raumforderungen und Punktionen mit Drainageeinlage bei liquiden Prozessen ist die Zahl chirurgischer Exzisionsbiopsien und Abszesssanierungen zurueckgegangen. Diese Eingriffe werden in nahezu allen Organgebieten durchgefuehrt. Neben den Aspirationsbiopsien werden haeufig Schneid- oder Stanzbiopsien durchgefuehrt. Nach histologischer und immunhistologischer Untersuchung der hierbei gewonnenen Proben in der Pathologie kann fruehzeitig die nachfolgende Therapie geplant werden. Der vorliegende Beitrag soll einen allgemeinen Ueberblick ueber Methoden, Materialien, Indikationen und Kontraindikationen geben. Die ultraschallgesteuerten Biopsien sowie die Vakuumsaugbiopsien im Rahmen des Mammographiescreenings werden bewusst nicht besprochen. (orig.)

  6. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  7. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    International Nuclear Information System (INIS)

    Koethe, Yilun; Xu, Sheng; Velusamy, Gnanasekar; Wood, Bradford J.; Venkatesan, Aradhana M.

    2014-01-01

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  8. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Koethe, Yilun [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Duke University School of Medicine, Durham, NC (United States); Xu, Sheng [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); Velusamy, Gnanasekar [Perfint Healthcare Pvt. Ltd., Chennai (India); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Venkatesan, Aradhana M. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States)

    2014-03-15

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  9. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heerink, W.J.; Vliegenthart, R. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Bock, G.H. de [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Epidemiology, University of Groningen, Groningen (Netherlands); Jonge, G.J. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Groen, H.J.M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Pulmonary Medicine, University of Groningen, Groningen (Netherlands); Oudkerk, M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands)

    2017-01-15

    To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. (orig.)

  10. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel (Dept. of Radiology, Medical Faculty, Univ. Duesseldorf, Duesseldorf (Germany)), email: Patric.Kroepil@med.uni-duesseldorf.de

    2011-10-15

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 +- 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 +- 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 +- 33 vs. n = 126 +- 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  11. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    International Nuclear Information System (INIS)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel

    2011-01-01

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 ± 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 ± 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 ± 33 vs. n = 126 ± 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  12. Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; d'Amore, Francesco; Mylam, Karen Juul

    2012-01-01

    PURPOSETo investigate whether bone marrow biopsy (BMB) adds useful information to [(18)F]fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) staging in patients with Hodgkin lymphoma (HL). PATIENTS AND METHODSNewly diagnosed patients with HL undergoing a pretherapeu...

  13. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens; Universidade Federal do Espirito Santo

    2017-01-01

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  14. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Universidade Federal do Espirito Santo (HUCAM/UFES), Vitoria, ES (Brazil). Hospital Universitario Cassiano Antonio de Morais. Radiologia e Diagnostico por Imagem

    2017-03-15

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  15. Computed tomography of von Meyenburg complex simulating micro-abscesses

    International Nuclear Information System (INIS)

    Sada, P.N.; Ramakrishna, B.

    1994-01-01

    A case is presented of a bile duct hamartoma in a 44 year old man being evaluated for abdominal pain. The computed tomography (CT) findings suggested micro-abscesses in the liver and a CT guided tru-cut biopsy showed von Meyenburg complex. 9 refs., 3 figs

  16. Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Hirose, Takashi; Mori, Kiyoshi; Machida, Suguru; Tominaga, Keigo; Yokoi, Kohei; Adachi, Mitsuru

    2000-01-01

    The purpose of this study was to evaluate the usefulness of computed tomographic (CT) fluoroscopy-guided transthoracic needle biopsy (TTNB) with an 18-gauge automatic biopsy gun for the diagnosis of pulmonary nodules. Between March 1996 and January 1998, 50 patients in whom pulmonary lesions could not be diagnosed cytopathologically with fiberoptic bronchoscopy or were not clearly visualized with fluoroscopy underwent CT fluoroscopy-guided TTNB. Final pathological diagnoses were 23 lung carcinomas, five pulmonary metastases and 22 benign lesions. Sufficient tissue for analysis was obtained from 48 of the 50 lesions (96%). The overall diagnostic yield of CT fluoroscopy-guided TTNB was 90%. The sensitivity, specificity and accuracy for malignancy were 89%, 100% and 94%, respectively. In 20 of the 22 cases (91%) of benign lesions, histological analysis yielded correct and specific diagnoses. Complications occurred in 22 of the 50 cases (44%). The most common complication was pneumothorax, which occurred in 21 of the 50 cases (42%). Chest tube insertion was required in 6 (12%). Although CT fluoroscopy could not decrease the complication rate, CT fluoroscopy-guided TTNB with an automatic biopsy gun appears to be a promising technique for diagnosing pulmonary lesions, particularly benign lesions. (author)

  17. Feasibility and effectiveness of image-guided percutaneous biopsy of the urinary bladder.

    Science.gov (United States)

    Butros, Selim Reha; McCarthy, Colin James; Karaosmanoğlu, Ali Devrim; Shenoy-Bhangle, Anuradha S; Arellano, Ronald S

    2015-08-01

    To evaluate the indications, technique, results, and complications of image-guided percutaneous biopsy of the urinary bladder. This retrospective study included 15 patients (10 male, 5 female) who underwent image-guided percutaneous biopsy of the urinary bladder between January 1999 and December 2013. The medical records, imaging studies, procedural details, and long-term follow-up of each patient were reviewed in detail to assess the feasibility of percutaneous bladder biopsy. Ten patients had focal bladder masses and 5 patients had asymmetric or diffuse bladder wall thickening. Eleven patients had either negative or unsatisfactory cystoscopies prior to the biopsy. Percutaneous biopsies were performed under computed tomography guidance in 12 patients and ultrasound in 3 patients. All procedures were technically successful and there were no procedural complications. Malignancy was confirmed in 8 patients, among whom 6 had transitional cell carcinoma, 1 cervical cancer, and 1 prostate cancer metastasis. Seven patients had a benign diagnosis, including 3 that were later confirmed by pathology following surgery and 2 patients with a false-negative result. The overall sensitivity was 80% and accuracy was 87%. Image-guided percutaneous biopsy of the urinary bladder is a safe and technically feasible procedure with a high sensitivity and accuracy rate. Although image-guided bladder biopsy is an uncommon procedure, it should be considered in selected cases when more traditional methods of tissue sampling are either not possible or fail to identify abnormalities detected by cross-sectional imaging.

  18. Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases

    International Nuclear Information System (INIS)

    Rimondi, Eugenio; Rossi, Giuseppe; Bartalena, Tommaso; Ciminari, Rosanna; Alberghini, Marco; Ruggieri, Pietro; Errani, Costantino; Angelini, Andrea; Calabro, Teresa; Abati, Caterina Novella; Balladelli, Alba; Tranfaglia, Cristina; Mavrogenis, Andreas F.; Vanel, Daniel; Mercuri, Mario

    2011-01-01

    Introduction: Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications. Materials and methods: We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors' institution. The results obtained are subject of this paper. Results: In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome. Conclusion: This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.

  19. Fatal paradoxical pulmonary air embolism complicating percutaneous computed tomography-guided needle biopsy of the lung

    International Nuclear Information System (INIS)

    Chakravarti, Rajesh; Singh, Virendra; Isaac, Rethish; John, Joseph

    2004-01-01

    A 63-year-old man with left upper zone haziness on chest X-ray and an infiltrative lesion with a pleural mass in the left upper lobe on CT scan was scheduled for CT-guided percutaneous trans-thoracic needle biopsy. During the procedure, the patient had massive haemoptysis and cardiorespiratory arrest and could not be revived. Post-mortem CT showed air in the right atrium, right ventricle, pulmonary artery and also in the left atrium and aorta. A discussion on paradoxical air embolism following percutaneous trans-thoracic needle biopsy is presented Copyright (2004) Blackwell Publishing Asia Pty Ltd

  20. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  1. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  2. Design and analysis of a tendon-based computed tomography-compatible robot with remote center of motion for lung biopsy.

    Science.gov (United States)

    Yang, Yunpeng; Jiang, Shan; Yang, Zhiyong; Yuan, Wei; Dou, Huaisu; Wang, Wei; Zhang, Daguang; Bian, Yuan

    2017-04-01

    Nowadays, biopsy is a decisive method of lung cancer diagnosis, whereas lung biopsy is time-consuming, complex and inaccurate. So a computed tomography-compatible robot for rapid and precise lung biopsy is developed in this article. According to the actual operation process, the robot is divided into two modules: 4-degree-of-freedom position module for location of puncture point is appropriate for patient's almost all positions and 3-degree-of-freedom tendon-based orientation module with remote center of motion is compact and computed tomography-compatible to orientate and insert needle automatically inside computed tomography bore. The workspace of the robot surrounds patient's thorax, and the needle tip forms a cone under patient's skin. A new error model of the robot based on screw theory is proposed in view of structure error and actuation error, which are regarded as screw motions. Simulation is carried out to verify the precision of the error model contrasted with compensation via inverse kinematics. The results of insertion experiment on specific phantom prove the feasibility of the robot with mean error of 1.373 mm in laboratory environment, which is accurate enough to replace manual operation.

  3. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  4. Pathologic fracture through a unicameral bone cyst of the pelvis: CT-guided percutaneous curettage, biopsy, and bone matrix injection.

    Science.gov (United States)

    Tynan, Jennifer R; Schachar, Norman S; Marshall, Geoffrey B; Gray, Robin R

    2005-02-01

    Unicameral bone cysts of the pelvis are extremely rare. A 19-year old man presented with a pathologic fracture through a pelvic unicameral bone cyst. He was treated with computed tomography-guided percutaneous curettage, biopsy, and demineralized bone matrix injection. Treatment has proven successful in short-term follow-up.

  5. Preoperative Computed Tomography-Guided Percutaneous Hookwire Localization of Metallic Marker Clips in the Breast with a Radial Approach: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, T.; Kasami, M.; Uchida, Y.; Sanuki, J.; Kimura, K.; Tanaka, K.; Takahashi, K. [Dept. of Diagnostic Radiology, Dept. of Pathology, and Dept. of Breast Surgery, Shizuoka Cancer Center Hospital, Naga-izumi, Shizuoka (Japan)

    2007-07-15

    Background: Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. Purpose: To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Material and Methods: Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. Results: CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). Conclusion: CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  6. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    Science.gov (United States)

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  7. Automatic path proposal computation for CT-guided percutaneous liver biopsy.

    Science.gov (United States)

    Helck, A; Schumann, C; Aumann, J; Thierfelder, K; Strobl, F F; Braunagel, M; Niethammer, M; Clevert, D A; Hoffmann, R T; Reiser, M; Sandner, T; Trumm, C

    2016-12-01

    To evaluate feasibility of automatic software-based path proposals for CT-guided percutaneous biopsies. Thirty-three patients (60 [Formula: see text] 12 years) referred for CT-guided biopsy of focal liver lesions were consecutively included. Pre-interventional CT and dedicated software (FraunhoferMeVis Pathfinder) were used for (semi)automatic segmentation of relevant structures. The software subsequently generated three path proposals in downward quality for CT-guided biopsy. Proposed needle paths were compared with consensus proposal of two experts (comparable, less suitable, not feasible). In case of comparable results, equivalent approach to software-based path proposal was used. Quality of segmentation process was evaluated (Likert scale, 1 [Formula: see text] best, 6 [Formula: see text] worst), and time for processing was registered. All biopsies were performed successfully without complications. In 91 % one of the three automatic path proposals was rated comparable to experts' proposal. None of the first proposals was rated not feasible, and 76 % were rated comparable to the experts' proposal. 7 % automatic path proposals were rated not feasible, all being second choice ([Formula: see text]) or third choice ([Formula: see text]). In 79 %, segmentation at least was good. Average total time for establishing automatic path proposal was 42 [Formula: see text] 9 s. Automatic software-based path proposal for CT-guided liver biopsies in the majority provides path proposals that are easy to establish and comparable to experts' insertion trajectories.

  8. Investigation of tissue cellularity at the tip of the core biopsy needle with optical coherence tomography.

    Science.gov (United States)

    Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H

    2018-02-01

    We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.

  9. Neuronavigator-guided cerebral biopsy.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-01-01

    Neuronavigators are new dynamic interactive instruments that use on-line computers to orient imaging data to the surgical field and guide the neurosurgeon to his target. We have been working since 1987 on a neuronavigator that serves not only as a precise pointer, but also as a dynamic arm that can be used to hold instruments, such as biopsy guides. The neuronavigator arm consists of six joints with optical encoders and is attached to the Mayfield headholder. The arm is connected to a workstation running customized 3D image graphics software. Special instruments and surgical technique have been developed. Here, we report on early clinical experience with ten biopsy procedures: 4 low-grade and 3 high-grade astrocytomas, one craniopharyngioma and one chronic intracerebral haematoma and intracerebral cyst, both of the latter with surrounding tumour suspect tissue. In all glioma cases serial biopsies were taken from optimal sites under ultrasound imaging control. Eight cases showed representative tumour tissue, while in two cases neoplasia was ruled out. The neuronavigator proved to be versatile, allowing comprehensive imaging data to be adapted to the surgical field.

  10. Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery.

    Science.gov (United States)

    Watanabe, E; Watanabe, T; Manaka, S; Mayanagi, Y; Takakura, K

    1987-06-01

    A new device was invented as an adjunct for computed tomography (CT)-guided stereotaxic or open neurosurgery. It is composed of a multijoint three-dimensional digitizer (sensor arm) and a microcomputer, which indicates the place of the sensor arm tip on preoperative CT images. Computed tomography scan is performed preoperatively with three markers placed on the nasion and ears. At surgery, after fixing the patient's head and the sensor arm, sampling of the standard points was done to translate the position of the tip of the sensor arm onto the CT images displayed on a computer screen. In this way positional data from conventional preoperative CT scan can be directly transferred into the surgical field. This system has the unique feature of introducing CT-guided stereotaxis into conventional open neurosurgery.

  11. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy

    International Nuclear Information System (INIS)

    Khan, M.F.; Straub, R.; Moghaddam, S.R.; Maataoui, A.; Gurung, J.; Thalhammer, A.; Vogl, T.J.; Jacobi, V.; Wagner, T.O.F.; Ackermann, H.

    2008-01-01

    The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size <4 cm is strongly correlated with higher occurence of perifocal hemorrhage (P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax. (orig.)

  12. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  13. Role of [18F]fluorodeoxyglucose positron emission tomography-computed tomography, sonography, and sonographically guided fine-needle aspiration biopsy in the diagnosis of axillary lymph nodes in patients with breast cancer: comparison of diagnostic performance.

    Science.gov (United States)

    Sohn, Yu-Mee; Hong, Il Ki; Han, Kyunghwa

    2014-06-01

    The aim of this study was to compare the diagnostic performance of [(18)F]fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) with that of sonography and sonographically guided fine-needle aspiration (FNA) for determining the preoperative axillary lymph node (ALN) status and to evaluate the factors related to false-negative PET-CT, sonographic, and FNA results in ALN staging of invasive ductal carcinoma. From March 2009 to July 2012, 226 patients had a diagnosis of primary breast cancer. Among these patients, 107 constituted the study population after exclusion of transferred patients and patients with breast cancer other than invasive ductal carcinoma. The diagnostic performance of the modalities was compared with pathologic reports. Univariate and multivariate analyses were used to evaluate the relationship between clinicopathologic factors (symptoms, T stage, hormone receptors, and histologic grade), false-negative results, and true-negative results on PET-CT, sonography, and FNA. Of the 107 patients, 45 (42.1%) had positive results on final pathologic analysis of ALNs. Sonographically guided FNA had a significantly higher specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve than sonography and PET-CT (P < .01). When sonography and PET-CT were combined, the sensitivity was significantly improved (P = .019) compared with sonography alone. When FNA and PET-CT were combined, the sensitivity and negative predictive value were significantly increased compared with each modality (P < .01). Sonographically guided FNA was found to be an excellent diagnostic tool for preoperative evaluation of the ALN status. To obviate the step of sentinel lymph node biopsy for determining the ALN status, combined evaluation of ALNs by these modalities may be more complementary than the use of a single modality. © 2014 by the American Institute of Ultrasound in Medicine.

  14. Development of a guidance guide for dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Fontes, Ladyjane Pereira

    2016-01-01

    Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR. (author)

  15. The value of ultrasound with ultrasound-guided fine-needle aspiration biopsy compared to computed tomography in the detection of regional metastases in the clinically negative neck

    International Nuclear Information System (INIS)

    Takes, Robert P.; Righi, Paul; Meeuwis, Cees A.; Manni, Johannes J.; Knegt, Paul; Marres, Henri A.M.; Spoelstra, Hubert A.A.; Boer, Maarten F. de; Mey, Andel G.L. van der; Bruaset, I.; Ball, Valerie; Weisberger, Edward; Radpour, Shokri; Kruyt, Rene H.; Joosten, Frank B.M.; Lameris, Johan S.; Oostayen, Jacques A. van; Kopecky, Kenyon; Caldemeyer, Karen; Henzen-Logmans, Sonja C.; Wiersma-van Tilburg, J.M.; Bosman, Fred T.; Krieken, J. Han J.M. van; Hermans, Jo; Baatenburg de Jong, Robert J.

    1998-01-01

    Purpose: Head and neck oncologists have not reached consensus regarding the role of contemporary imaging techniques in the evaluation of the clinically negative neck in patients with head and neck squamous cell carcinoma (HNSCC). The purpose of the present study was to compare the accuracy of ultrasound with guided fine-needle aspiration biopsy (UGFNAB) and computed tomography (CT) in detecting lymph node metastasis in the clinically negative neck. Methods and Materials: Sixty-four neck sides of patients with HNSCC were examined preoperatively by ultrasound/UGFNAB and CT at one of five participating tertiary care medical centers. The findings were correlated with the results of histopathologic examination of the neck specimen. Results: Ultrasound with guided fine-needle aspiration biopsy was characterized by a sensitivity of 48%, specificity of 100%, and overall accuracy of 79%. Three cases had nondiagnostic aspirations using UGFNAB and were excluded. CT demonstrated a sensitivity of 54%, specificity of 92%, and overall accuracy of 77%. UGFNAB detected two additional metastases not visualized on CT, whereas CT detected no metastases not seen on UGFNAB. The results of UGFNAB were similar between the participating centers. Conclusions: Approximately one half of the clinically occult nodal metastases in our patient group were identified by both CT and UGFNAB. Overall, UGFNAB and CT demonstrated comparable accuracy. The sensitivity of CT was slightly better than UGFNAB, but the latter remained characterized by a superior specificity. The results of CT and UGFNAB did not appear to be supplementary. The choice of imaging modality for staging of the clinically negative neck depends on tumor site, T-stage, and experience and preference of the head and neck oncologist. If CT is required for staging of the primary tumor, additional staging of the neck by UGFNAB does not provide significant additional value

  16. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  17. Dedifferentiated chondrosarcoma: use of MRI to guide needle biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Saifuddin, A. E-mail: asaifuddin@aol.com; Mann, B.S.; Mahroof, S.; Pringle, J.A.S.; Briggs, T.W.R.; Cannon, S.R

    2004-03-01

    AIM: To describe the use of MRI to identify and biopsy areas of dedifferentiation in patients with a suspected diagnosis of dedifferentiated chondrosarcoma. MATERIALS AND METHODS: Low-grade chondrosarcoma is characterized at magnetic resonance imaging (MRI) as having a lobulate, hyperintense appearance on T2-weighted spin-echo sequences. T2-weighted MR images were assessed in 15 patients with a final pathological diagnosis of dedifferentiated chondrosarcoma for regions of atypical reduced signal intensity. Information regarding the site of ultrasound or computed tomography (CT)-guided biopsy was available in 10 cases. RESULTS: Nine patients were male and six female with a mean age of 60 years (range 25-77 years). The sites involved were the distal femur (n=4), pelvis (n=3), proximal femur (n=4), femoral diaphysis (n=1), proximal humerus (n=2) and proximal tibia (n=1). The dedifferentiated component consisted of osteosarcoma (n=5), malignant fibrous histiocytoma (n=6), spindle cell sarcoma (n=1), leiomyosarcoma (n=1) and pleomorphic sarcoma (n=1). In 14 of the 15 cases, areas of lower signal intensity lacking in lobulation were identified. In nine of the 10 cases, biopsy site included such areas and yielded high-grade sarcoma. CONCLUSIONS: Dedifferentiation within chondrosarcoma may be identified on T2-weighted MRI as areas of reduced signal intensity. These areas should be the preferred site of biopsy.

  18. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  19. Evaluation of chronic infectious interstitial pulmonary disease in children by low-dose CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, Christoph M.; Lemburg, Stefan P.; Kagel, Thomas; Nicolas, Volkmar [Ruhr-University of Bochum, Institute of Diagnostic Radiology, Interventional Radiology and Nuclear Medicine, BG Clinics Bergmannsheil, Bochum (Germany); Mueller, Klaus-Michael [Ruhr-University of Bochum, Institute of Pathology, BG Clinics Bergmannsheil, Bochum (Germany); Nuesslein, Thomas G.; Rieger, Christian H.L. [Ruhr-University of Bochum, Pediatric Hospital, Bochum (Germany)

    2005-07-01

    Children with chronic infectious interstitial lung disease often have to undergo open lung biopsy to establish a final diagnosis. Open lung biopsy is an invasive procedure with major potential complications. Transthoracic lung biopsy (TLB) guided by computed tomography (CT) is a less-invasive well-established procedure in adults. Detailing the role of low-dose CT-guided TLB in the enhanced diagnosis of chronic lung diseases related to infection in children. A group of 11 children (age 8 months to 16 years) underwent CT-guided TLB with a 20-gauge biopsy device. All investigations were done under general anaesthesia on a multidetector CT scanner (SOMATOM Volume Zoom, Siemens, Erlangen, Germany) using a low-dose protocol (single slices, 120 kV, 20 mAs). Specimens were processed by histopathological, bacteriological, and virological techniques. All biopsies were performed without major complications; one child developed a small pneumothorax that resolved spontaneously. A diagnosis could be obtained in 10 of the 11 patients. Biopsy specimens revealed chronic interstitial alveolitis in ten patients. In five patients Chlamydia pneumoniae PCR was positive, in three Mycoplasma pneumoniae PCR was positive, and in two Cytomegalovirus PCR was positive. The average effective dose was 0.83 mSv. Low-dose CT-guided TLB can be a helpful tool in investigating chronic infectious inflammatory processes in children with minimal radiation exposure. It should be considered prior to any open surgical procedure performed for biopsy alone. In our patient group no significant complication occurred. A disadvantage of the method is that it does not allow smaller airways and vessels to be assessed. (orig.)

  20. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  1. Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

    International Nuclear Information System (INIS)

    Fritz, Jan; Tzaribachev, Nikolay; Thomas, Christoph; Wehrmann, Manfred; Horger, Marius S.; Carrino, John A.; König, Claudius W.; Pereira, Philippe L.

    2012-01-01

    Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)—guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree; Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.

  2. Use of percutaneous image-guided coaxial core-needle biopsy for diagnosis of intraabdominal lymphoma

    International Nuclear Information System (INIS)

    Shimizu, Ikuo; Okazaki, Yoichi; Takeda, Wataru; Kirihara, Takehiko; Sato, Keijiro; Fujikawa, Yuko; Ueki, Toshimitsu; Hiroshima, Yuki; Sumi, Masahiko; Ueno, Mayumi; Ichikawa, Naoaki; Kobayashi, Hikaru

    2014-01-01

    Although pathological diagnosis is essential for managing malignant lymphoma, intraabdominal lesions are generally difficult to approach due to the invasiveness of abdominal surgery. Here, we report the use of percutaneous image-guided coaxial core-needle biopsy (CNB) to obtain intraabdominal specimens for diagnosing intraabdominal lymphomas, which typically requires histopathological and immunohistochemical evaluation. We retrospectively reviewed consecutive cases involving computed tomography (CT)- or ultrasonography (US)-guided CNB to obtain pathological specimens for intraabdominal lesions from 1999 to 2011. Liver, spleen, kidney, and inguinal node biopsies were excluded. We compared CNBs with laparotomic biopsies. A total of 66 CNBs were performed for 59 patients (32 males, 27 females; median age, 63.5), including second or third repeat procedures. Overall diagnostic rate was 88.5%. None of the patients required additional surgical biopsies. Notably, the median interval between recognition of an intraabdominal mass and biopsy was only 1 day. Forty-five procedures were performed for hematological malignancies. Adequate specimens were obtained for histopathological diagnosis in 86% of cases. Flow cytometry detected lymphoma cells in 79.5% of cases. Twelve patients (nine males, three females; median age, 60) were eligible for surgical biopsy. While every postoperative course was satisfactory, median duration from lesion recognition to therapy initiation for lymphoma cases was significantly shorter for CNB than for surgical biopsy (14 vs. 35 days). While one-fourth of the patients were not eligible for the procedures, CNB is safe and highly effective for diagnosis of intraabdominal lymphomas. This method significantly improves sampling and potentially helps attain immunohistological distinction, allowing for more timely therapy initiation

  3. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  4. C-arm cone-beam CT virtual navigation-guided percutaneous mediastinal mass biopsy: Diagnostic accuracy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungjin [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Aerospace Medical Group, Air Force Education and Training Command, Jinju (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2015-12-15

    To assess the usefulness of C-arm cone-beam computed tomography (CBCT) virtual navigation-guided percutaneous mediastinal mass biopsy in terms of diagnostic accuracy and complication rates. Seventy-eight CBCT virtual navigation-guided percutaneous mediastinal mass biopsies were performed in 75 patients (M:F, 38:37; mean age, 48.55 ± 18.76 years). The procedural details, diagnostic sensitivity, specificity, accuracy and complication rate were investigated. Mean lesion size was 6.80 ± 3.08 cm, skin-to-target distance was 3.67 ± 1.80 cm, core needle biopsy rate was 96.2 % (75/78), needle indwelling time was 9.29 ± 4.34 min, total procedure time was 13.26 ± 5.29 min, number of biopsy specimens obtained was 3.13 ± 1.02, number of CBCTs performed was 3.03 ± 0.68, rate of lesion border discrimination from abutting mediastinal structures on CBCT was 26.9 % (21/78), technical success rate was 100 % (78/78), estimated effective dose was 5.33 ± 4.99 mSv, and the dose area product was 12,723.68 ± 10,665.74 mGy.cm{sup 2}. Among the 78 biopsies, 69 were malignant, 7 were benign and 2 were indeterminate. Diagnostic sensitivity, specificity and accuracy for the diagnosis of malignancies were 97.1 % (67/69), 100 % (7/7) and 97.4 % (74/76), respectively, with a complication rate of 3.85 % (3/78), all of which were small pneumothoraces. CBCT virtual navigation-guided biopsy is a highly accurate and safe procedure for the evaluation of mediastinal lesions. (orig.)

  5. Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant

    Directory of Open Access Journals (Sweden)

    Patricia M. de Groot, MD

    2018-04-01

    Full Text Available Purpose: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT on computed tomography (CT scans after the use of tract sealants can mimic malignant tract seeding (MTS and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs. Methods and materials: A total of 406 lung biopsies were performed in oncology patients using a tract sealant over 19 months. Of these patients, 326 had follow-up CT scans and were included in the study group. Four thoracic radiologists retrospectively analyzed the imaging, and a pathologist examined 10 resected LBTs. Results: A total of 234 of 326 biopsies (72%, including primary lung cancer [n = 98]; metastases [n = 81]; benign [n = 50]; and nondiagnostic [n = 5] showed an LBT on CT. LBTs were identified on imaging 0 to 3 months after biopsy. LBTs were typically straight or serpiginous with a thickness of 2 to 5 mm. Most LBTs were unchanged (92% or decreased (6.3% over time. An increase in LBT thickness/nodularity that was suspicious for MTS occurred in 4 of 234 biopsies (1.7%. MTS only occurred after biopsy of metastases from extrathoracic malignancies, and none occurred in patients with lung cancer. Conclusions: LBTs are common on CT after lung biopsy using a tract sealant. MTS is uncommon and only occurred in patients with extrathoracic malignancies. No MTS was found in patients with primary lung cancer. Accordingly, potential alteration in planned therapy should be considered only in patients with LBTs and extrathoracic malignancies being considered for stereotactic body radiation therapy or wedge resection.

  6. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  7. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  8. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  9. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo; Matsumoto, Tomohiro; Hasebe, Terumitsu; Kakizawa, Hideaki; Toyoda, Naoyuki

    2014-01-01

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  10. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  11. Difficulties encountered managing nodules detected during a computed tomography lung cancer screening program.

    Science.gov (United States)

    Veronesi, Giulia; Bellomi, Massimo; Scanagatta, Paolo; Preda, Lorenzo; Rampinelli, Cristiano; Guarize, Juliana; Pelosi, Giuseppe; Maisonneuve, Patrick; Leo, Francesco; Solli, Piergiorgio; Masullo, Michele; Spaggiari, Lorenzo

    2008-09-01

    The main challenge of screening a healthy population with low-dose computed tomography is to balance the excessive use of diagnostic procedures with the risk of delayed cancer detection. We evaluated the pitfalls, difficulties, and sources of mistakes in the management of lung nodules detected in volunteers in the Cosmos single-center screening trial. A total of 5201 asymptomatic high-risk volunteers underwent screening with multidetector low-dose computed tomography. Nodules detected at baseline or new nodules at annual screening received repeat low-dose computed tomography at 1 year if less than 5 mm, repeat low-dose computed tomography 3 to 6 months later if between 5 and 8 mm, and fluorodeoxyglucose positron emission tomography if more than 8 mm. Growing nodules at the annual screening received low-dose computed tomography at 6 months and computed tomography-positron emission tomography or surgical biopsy according to doubling time, type, and size. During the first year of screening, 106 patients underwent lung biopsy and 91 lung cancers were identified (70% were stage I). Diagnosis was delayed (false-negative) in 6 patients (stage IIB in 1 patient, stage IIIA in 3 patients, and stage IV in 2 patients), including 2 small cell cancers and 1 central lesion. Surgical biopsy revealed benign disease (false-positives) in 15 cases (14%). Positron emission tomography sensitivity was 88% for prevalent cancers and 70% for cancers diagnosed after first annual screening. No needle biopsy procedures were performed in this cohort of patients. Low-dose computed tomography screening is effective for the early detection of lung cancers, but nodule management remains a challenge. Computed tomography-positron emission tomography is useful at baseline, but its sensitivity decreases significantly the subsequent year. Multidisciplinary management and experience are crucial for minimizing misdiagnoses.

  12. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  13. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo

    2017-01-01

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications

  14. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms.

    Science.gov (United States)

    Ben-Shlomo, A; Cohen, D; Bruckheimer, E; Bachar, G N; Konstantinovsky, R; Birk, E; Atar, E

    2016-05-01

    To compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT. Effective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms. The effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590% for upper lung, 639 and 525% for mid-lung, and 461 and 251% for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762% for liver and 513 and 608% for kidney biopsies. Based on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  15. CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure.

    Science.gov (United States)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.

  16. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  17. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  18. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Cohen, D.; Bruckheimer, E.; Bachar, G. N.; Konstantinovsky, R.; Birk, E.; Atar, E.

    2016-01-01

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  19. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A. [Soreq NRC, Radiation Protection Domain (Israel); Cohen, D.; Bruckheimer, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Bachar, G. N.; Konstantinovsky, R. [Rabin Medical Center, Department of Diagnostic Radiology (Israel); Birk, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Atar, E., E-mail: elia@clalit.org.il [Rabin Medical Center, Department of Diagnostic Radiology (Israel)

    2016-05-15

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  20. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  1. Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2014-01-01

    Aim: To evaluate the factors influencing diagnostic yield of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for bone lesions. Materials and methods: Between September 2005 and July 2011, 162 consecutive CT-guided CNB procedures were performed in 155 patients. The variables analysed were age, sex, lesion location, lesion type, lesion size, specimen size, biopsy needle gauge, and individual radiologist. The factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were determined by multivariate analysis of variables. Results: The diagnostic yield was 81.5%. Diagnostic yield was 89.9% for lytic bone lesions and 48.5% for sclerotic bone lesions (p < 0.001), and 89.2% for lesions ≥3 cm and 73.4% for lesions <3 cm (p = 0.010). The significant factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were lesion type [p < 0.001; odds ratio (OR) for a lytic lesion was approximately 12 times higher than that for a sclerotic lesion; 95% confidence interval (CI): 4.22–34.01], and lesion size (p = 0.012; OR for a lesion size ≥3 cm was about five-times higher than that for a lesion size <3 cm; 95% CI: 1.42–16.71). Conclusion: Lesion type and lesion size are determining factors in diagnostic yield. The higher diagnostic yield is correlated with lytic lesion and lesion size ≥3 cm

  2. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  3. Imaging regional variation of cellular proliferation in gliomas using 3'-deoxy-3'-[18F]fluorothymidine positron-emission tomography: an image-guided biopsy study

    International Nuclear Information System (INIS)

    Price, S.J.; Fryer, T.D.; Cleij, M.C.; Dean, A.F.; Joseph, J.; Salvador, R.; Wang, D.D.; Hutchinson, P.J.; Clark, J.C.; Burnet, N.G.; Pickard, J.D.; Aigbirhio, F.I.

    2009-01-01

    Aim: To compare regional variations in uptake of 3'-deoxy-3'- [ 18 F]-fluorothymidine (FLT) images using positron-emission tomography (PET) with measures of cellular proliferation from biopsy specimens obtained by image-guided brain biopsies. Materials and methods: Fourteen patients with a supratentorial glioma that required an image-guided brain biopsy were imaged preoperatively with dynamic PET after the administration of FLT. Maps of FLT irreversible uptake rate (K i ) and standardized uptake value (SUV) were calculated. These maps were co-registered to a gadolinium-enhanced T1-weighted spoiled gradient echo (SPGR) sequence that was used for biopsy guidance, and the mean and maximum K i and SUV determined for each biopsy site. These values were correlated with the MIB-1 labelling index (a tissue marker of proliferation) from these biopsy sites. Results: A total of 57 biopsy sites were studied. Although all measures correlated with MIB-1 labelling index, K i max provided the best correlation (Pearson coefficient, r = 0.68; p i mean (±SD) was significantly higher than in normal tissue (3.3 ± 1.7 x 10 -3 ml plasma /min/ml tissue versus 1.2 ± 0.7 x 10 -3 ml plasma /min/ml tissue ; p = 0.001). High-grade gliomas showed heterogeneous uptake with a mean K i of 7.7 ± 4 x 10 -3 ml plasma /min/ml tissue . A threshold K i mean of 1.8 x 10 -3 differentiates between normal tissue and tumour (sensitivity 84%, specificity 88%); however, the latter threshold underestimated the extent of tumour in half the cases. SUV closely agreed with K i measurements. Conclusion: FLT PET is a useful marker of cellular proliferation that correlates with regional variation in cellular proliferation; however, it is unable to identify the margin of gliomas

  4. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  5. High-resolution computed tomography and histopathological findings in hypersensitivity pneumonitis: a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Pedro Paulo Teixeira e Silva; Moreira, Marise Amaral Reboucas; Silva, Daniela Graner Schuwartz Tannus; Moreira, Maria Auxiliadora do Carmo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil); Gama, Roberta Rodrigues Monteiro da [Hospital do Cancer de Barretos, Barretos, SP (Brazil); Sugita, Denis Masashi, E-mail: pedroptstorres@yahoo.com.br [Anapolis Unievangelica, Anapolis, GO (Brazil)

    2016-03-15

    Hypersensitivity pneumonitis is a diffuse interstitial and granulomatous lung disease caused by the inhalation of any one of a number of antigens. The objective of this study was to illustrate the spectrum of abnormalities in high-resolution computed tomography and histopathological findings related to hypersensitivity pneumonitis. We retrospectively evaluated patients who had been diagnosed with hypersensitivity pneumonitis (on the basis of clinical-radiological or clinical-radiological-pathological correlations) and had undergone lung biopsy. Hypersensitivity pneumonitis is clinically divided into acute, subacute, and chronic forms; high-resolution computed tomography findings correlate with the time of exposure; and the two occasionally overlap. In the subacute form, centrilobular micronodules, ground glass opacities, and air trapping are characteristic high-resolution computed tomography findings, whereas histopathology shows lymphocytic inflammatory infiltrates, bronchiolitis, variable degrees of organizing pneumonia, and giant cells. In the chronic form, high-resolution computed tomography shows traction bronchiectasis, honeycombing, and lung fibrosis, the last also being seen in the biopsy sample. A definitive diagnosis of hypersensitivity pneumonitis can be made only through a multidisciplinary approach, by correlating clinical findings, exposure history, high-resolution computed tomography findings, and lung biopsy findings. (author)

  6. PET/CT-guided interventions: Indications, advantages, disadvantages and the state of the art.

    Science.gov (United States)

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Koch, Guillaume; Tsoumakidou, Georgia; Caudrelier, Jean; Addeo, Pietro; Bachellier, Philippe; Namer, Izzie Jacques; Gangi, Afshin

    2018-02-01

    Positron emission tomography/computed tomography (PET/CT) represents an emerging imaging guidance modality that has been applied to successfully guide percutaneous procedures such as biopsies and tumour ablations. The aim of the present narrative review is to report the indications, advantages and disadvantages of PET/CT-guided procedures in the field of interventional oncology and to briefly describe the experience gained with this new emerging technique while performing biopsies and tumor ablations.

  7. Standards in radiographically guided biopsies - indications, techniques, complications

    International Nuclear Information System (INIS)

    Feuerbach, S.; Schreyer, A.; Schlottmann, K.

    2003-01-01

    In the first place, different needle types are presented, in particular, biopsy cannulae applying the ''TruCut'' principle and devices suitable for bone biopsy. Important aids for the daily practice, such as tandem technology and coaxial technology, are presented. Advantages and disadvantages are discussed, together with the most important sites of target-directed fluoroscopy, sonography and computer tomography as well as CT-fluoroscopy. Local anesthesia and analgosedation are presented, and the general and specific caliber- or entrance-dependent contraindications are described. The literature is reviewed for data of severe complications, such as death or tumor cell deposits along the puncture site. For the different targets in thorax and abdomen, the typical indications, points of entrance, contraindications, complications and special techniques are described, and the value of the biopsy for these localizations is presented. Under the heading ''Tips and Tricks'', practical advice useful for the daily routine can be found. (orig.) [de

  8. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  9. Comparison of ultrasound and computer tomography in the diagnosis of pleural shadowing

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Schmitt, W.G.H.

    1983-05-01

    Sonography was performed in 40 patients with pleural shadowing of uncertain origin in order to complement conventional X-ray examination. Where the findings were not clear-cut, computer tomography was performed subsequently and the diagnosis ascertained by biopsy or operation. Fluid-containing pleural lesions, such as encysted effusions and empyemas, pericardial cysts and one echinococcus cyst were identified by sonography from their appearance and biopsy was performed; computer tomography adds little additional information in these conditions. Solid pleural masses, on the other hand, can be more accurately defined by computer tomography. This shows the entire pleura, including small areas of calcification. Density measurements are able to differentiate various tissues, and particularly fat.

  10. CT fluoroscopy-guided renal tumour cutting needle biopsy. Retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure

    International Nuclear Information System (INIS)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. (orig.)

  11. CT fluoroscopy-guided renal tumour cutting needle biopsy. Retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu [Okayama University Medical School, Department of Radiology, Okayama (Japan)

    2018-01-15

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. (orig.)

  12. Diffuse abnormalities of the trachea: computed tomography findings

    International Nuclear Information System (INIS)

    Marchiori, Edson; Araujo Neto, Cesar de

    2008-01-01

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  13. First-in-Man Computed Tomography-Guided Percutaneous Revascularization of Coronary Chronic Total Occlusion Using a Wearable Computer: Proof of Concept.

    Science.gov (United States)

    Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Szpak, Marcin; Staruch, Adam D; Kepka, Cezary; Witkowski, Adam

    2016-06-01

    We report a case of successful computed tomography-guided percutaneous revascularization of a chronically occluded right coronary artery using a wearable, hands-free computer with a head-mounted display worn by interventional cardiologists in the catheterization laboratory. The projection of 3-dimensional computed tomographic reconstructions onto the screen of virtual reality glass allowed the operators to clearly visualize the distal coronary vessel, and verify the direction of the guide wire advancement relative to the course of the occluded vessel segment. This case provides proof of concept that wearable computers can improve operator comfort and procedure efficiency in interventional cardiology. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  15. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  16. How accurate are measurements of skin-lesion depths on prebiopsy supine chest computed tomography for transthoracic needle biopsies?

    International Nuclear Information System (INIS)

    Cheung, Joo Yeon; Kim, Yookyung; Shim, Sung Shine; Lee, Jin Hwa; Chang, Jung Hyun; Ryu, Yon Ju; Lee, Rena J.

    2012-01-01

    Aim: To evaluate the accuracy of depth measurements on supine chest computed tomography (CT) for transthoracic needle biopsy (TNB). Materials and methods: We measured skin-lesion depths from the skin surface to nodules on both prebiopsy supine CT scans and CT scans obtained during cone beam CT-guided TNB in the supine (n = 29) or prone (n = 40) position in 69 patients, and analyzed the differences between the two measurements, based on patient position for the biopsy and lesion location. Results: Skin-lesion depths measured on prebiopsy supine CT scans were significantly larger than those measured on CT scans obtained during TNB in the prone position (p < 0.001; mean difference ± standard deviation (SD), 6.2 ± 5.7 mm; range, 0–18 mm), but the differences showed marginal significance in the supine position (p = 0.051; 3.5 ± 3.9 mm; 0–13 mm). Additionally, the differences were significantly larger for the upper (mean ± SD, 7.8 ± 5.7 mm) and middle (10.1 ± 6.5 mm) lung zones than for the lower lung zones (3.1 ± 3.3 mm) in the prone position (p = 0.011), and were larger for the upper lung zone (4.6 ± 5.0 mm) than for the middle (2.4 ± 2.0 mm) and lower (2.3 ± 2.3 mm) lung zones in the supine position (p = 0.004). Conclusions: Skin-lesion depths measured on prebiopsy supine chest CT scans were inaccurate for TNB in the prone position, particularly for nodules in the upper and middle lung zones.

  17. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    Science.gov (United States)

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (ptechnical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Cone-Beam Computed Tomography-Guided Percutaneous Radiologic Gastrostomy

    International Nuclear Information System (INIS)

    Moehlenbruch, Markus; Nelles, Michael; Thomas, Daniel; Willinek, Winfried; Gerstner, Andreas; Schild, Hans H.; Wilhelm, Kai

    2010-01-01

    The purpose of this study was to investigate the feasibility of a flat-detector C-arm-guided radiographic technique (cone-beam computed tomography [CBCT]) for percutaneous radiologic gastrostomy (PRG) insertion. Eighteen patients (13 men and 5 women; mean age 62 years) in whom percutaneous endoscopic gastrostomy (PEG) had failed underwent CBCT-guided PRG insertion. PEG failure or unsuitability was caused by upper gastrointestinal tract obstruction in all cases. Indications for gastrostomy were esophageal and head and neck malignancies, respectively. Before the PRG procedure, initial C-arm CBCT scans were acquired. Three- and 2-dimensional soft-tissue reconstructions of the epigastrium region were generated on a dedicated workstation. Subsequently, gastropexy was performed with T-fasteners after CBCT-guided puncture of the stomach bubble, followed by insertion of an 14F balloon-retained catheter through a peel-away introducer. Puncture of the stomach bubble and PRG insertion was technically successful in all patients without alteration of the epigastric region. There was no malpositioning of the tube or other major periprocedural complications. In 2 patients, minor complications occurred during the first 30 days of follow-up (PRG malfunction: n = 1; slight infection: n = 1). Late complications, which were mainly tube disturbances, were observed in 2 patients. The mean follow-up time was 212 days. CBCT-guided PRG is a safe, well-tolerated, and successful method of gastrostomy insertion in patients in whom endoscopic gastrostomy is not feasible. CBCT provides detailed imaging of the soft tissue and surrounding structures of the epigastric region in one diagnostic tour and thus significantly improves the planning of PRG procedures.

  19. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  20. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    Science.gov (United States)

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  1. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  2. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  3. Diffuse optical tomography for breast cancer imaging guided by computed tomography: A feasibility study.

    Science.gov (United States)

    Baikejiang, Reheman; Zhang, Wei; Li, Changqing

    2017-01-01

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as hemoglobin, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer imaging. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at the wavelength of 650 nm and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements and width of measurement patch, have been investigated. Our results indicate that an air-cooling EMCCD camera is good enough for the transmission mode DOT imaging. We have also found that measurements at six angular projections are sufficient for DOT to reconstruct the optical targets with 2 and 4 times absorption contrast when the CT guidance is applied. Finally, we have described our future research plan on integration of a multispectral DOT imaging system into a breast CT scanner.

  4. A comparison of ultrasound and computer tomography in the diagnosis of pleural shadowing

    International Nuclear Information System (INIS)

    Kurtz, B.; Schmitt, W.G.H.

    1983-01-01

    Sonography was performed in 40 patients with pleural shadowing of uncertain origin in order to complement conventional X-ray examination. Where the findings were not clear-cut, computer tomography was performed subsequently and the diagnosis ascertained by biopsy or operation. Fluid-containing pleural lesions, such as encysted effusions and empyemas, pericardial cysts and one echinococcus cyst were identified by sonography from their appearance and biopsy was performed; computer tomography adds little additional information in these conditions. Solid pleural masses, on the other hand, can be more accurately defined by computer tomography. This shows the entire pleura, including small areas of calcification. Density measurements are able to differentiate various tissues, and particularly fat. (orig.) [de

  5. Fatal mediastinal biopsy: How interventional radiology saves the day

    Directory of Open Access Journals (Sweden)

    Y Yaacob

    2012-01-01

    Full Text Available This was a case of a 35-year-old man with mediastinal mass requiring computed tomography (CT-guided biopsy for tissue diagnosis. A posterior approach with an 18-gauge biopsy needle was used to obtain tissue sample. Post biopsy, patient condition deteriorated and multiphase CT study detected active bleeding in arterial phase at the biopsy site with massive hemothorax. Subsequent angiography showed arterial bleeder arising from the apical branch of the right pulmonary artery. Selective endovascular embolization with NBCA (n-Butyl cyanoacrylate was successful. Patient survived the complication. The case highlighted a rare complication in a common radiology procedure and the value of the interventional radiology unit in avoiding a fatal outcome.

  6. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    Science.gov (United States)

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  7. Nodular fasciitis of the face diagnosed by US-guided core needle biopsy: a case report

    International Nuclear Information System (INIS)

    Lee, Sang Kwon; Kwon, Sun Young

    2006-01-01

    We report here on a case of nodular fasciitis (NF) that was diagnosed by ultrasonography (US)-guided core needle biopsy in a 31-year-old man, and we include the US and computed tomographic (CT) findings and the histopathologic findings at US-guided core needle biopsy (CNB). We suggest that high-resolution US is useful for the detailed evaluation of NF in the superficial regions, such as the face, and US-guided CNB is useful for the definitive histologic diagnosis of NF without causing scarring

  8. Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France); Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Thénint, Marie-Aude, E-mail: marie-aude.thenint@chru-strasbourg.fr; Rao, Pramod, E-mail: pramodrao@me.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France)

    2016-07-15

    ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.

  9. Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography

    International Nuclear Information System (INIS)

    Shini, Mohanad; Rubinsky, Boris

    2008-01-01

    Biopsies are a reliable method for examining tissues and organs inside the body, in particular for detection of tumors. However, a single biopsy produces only limited information on the site from which it is taken. Therefore, tumor detection now employs multiple biopsy samplings to examine larger volumes of tissue. Nevertheless, even with multiple biopsies, the information remains discrete, while the costs of biopsy increase. Here we propose and evaluate the feasibility of using minimally invasive medical imaging as a means to overcome the limitations of discrete biopsy sampling. The minimally invasive medical imaging technique employs the biopsy probe as electrodes for measurements of electrical impedance tomography relevant data during each biopsy sampling. The data from multiple samplings are combined and used to produce an EIT image of the tissue. Two- and three-dimensional mathematical simulations confirm that the minimally invasive medical imaging technique can produce electrical impedance tomography images of the tissues between the biopsy probe insertion sites. We show that these images can detect tumors that would be missed with multiple biopsy samplings only, and that the technique may facilitate the detection of tumors with fewer biopsies, thereby reducing the cost of cancer detection

  10. Comparative analysis of diagnostic accuracy of different brain biopsy procedures.

    Science.gov (United States)

    Jain, Deepali; Sharma, Mehar Chand; Sarkar, Chitra; Gupta, Deepak; Singh, Manmohan; Mahapatra, A K

    2006-12-01

    Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different stereotactic and ultrasound-guided brain biopsy procedures. A retrospective analysis was conducted of all brain biopsies (frame-based and frameless stereotactic and ultrasound-guided) performed in a single tertiary care neurosciences center between 1995 and 2005. The overall diagnostic accuracy achieved on histopathology and correlation with type of biopsy technique was evaluated. A total of 130 cases were included, which consisted of 82 males and 48 females. Age ranged from 4 to 75 years (mean age 39.5 years). Twenty per cent (27 patients) were in the pediatric age group, while 12% (16 patients) were >or= 60-years of age. A definitive histological diagnosis was established in 109 cases (diagnostic yield 80.2%), which encompassed 101 neoplastic and eight nonneoplastic lesions. Frame-based, frameless stereotactic and ultrasound-guided biopsies were done in 95, 15 and 20 patients respectively. Although the numbers of cases were small there was trend for better yield with frameless image-guided stereotactic biopsy and maximum diagnostic yield was obtained i.e, 87% (13/15) in comparison to conventional frame-based CT-guided stereotactic biopsy and ultrasound-guided biopsy. Overall, a trend of higher diagnostic yield was seen in cases with frameless image-guided stereotactic biopsy. Thus, this small series confirms that frameless neuronavigator-guided stereotactic procedures represent the lesion sufficiently in order to make histopathologic diagnosis.

  11. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  12. Performance of intra-procedural 18-fluorodeoxyglucose PET/CT-guided biopsies for lesions suspected of malignancy but poorly visualized with other modalities

    International Nuclear Information System (INIS)

    Cornelis, F.; Silk, M.; Takaki, H.; Durack, J.C.; Erinjeri, J.P.; Sofocleous, C.T.; Siegelbaum, R.H.; Maybody, M.; Solomon, S.B.; Schoder, H.

    2014-01-01

    We sought to evaluate the safety and the diagnostic success rate of percutaneous biopsies performed under intra-procedural 18 F-deoxyglucose (FDG) positron-emission tomography/computed tomography (PET/CT) guidance for lesions difficult to see with conventional cross-sectional imaging. From 2011 to 2013, consecutive clinically indicated percutaneous PET/CT-guided biopsies of 106 masses (mean size, 3.3 cm; range, 0.7-15.9 cm; SD, 2.9 cm) in bones (n = 33), liver (n = 26), soft tissues (n = 18), lung (n = 15) and abdomen (n = 14) were reviewed. The biopsy procedures were performed following injection of a mean of 255 MBq (SD, 74) FDG. Mean maximal standardized uptake value (SUV) of lesions was 8.8 (SD, 6.3). A systematic review of the histopathological results and outcomes was performed. Biopsies were positive for malignancy in 76 cases (71.7 %, 76/106) and for benign tissue in 30 cases (28.3 %, 30/106). Immediate results were considered adequate for 100 PET/CT biopsies (94.3 %, 100/106) requiring no further exploration, and for the six others (5.7 %, 6/106) benign diagnoses were confirmed after surgery (n = 4) or follow-up (n = 2). The consequent overall sensitivity and the diagnostic success of biopsy were therefore 100 %. No significant differences in terms of detection of malignancy were observed between the different locations. Lesions > 2 cm or with SUV > 4 were not significantly more likely to be malignant. Complications occurred after four biopsies (3.7 %, 4/106). Intra-procedural PET/CT guidance appears as a safe and effective method and allows high diagnostic success of percutaneous biopsies for metabolically active lesions. (orig.)

  13. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  14. Diffuse reflectance imaging: a tool for guided biopsy

    Science.gov (United States)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  15. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    Directory of Open Access Journals (Sweden)

    Smriti Hari

    2016-01-01

    Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates.

  16. Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Imaging in Patients With Carcinoma of the Nasopharynx: Diagnostic Accuracy and Impact on Clinical Management

    International Nuclear Information System (INIS)

    Gordin, Arie; Golz, Avishay; Daitzchman, Marcello; Keidar, Zohar; Bar-Shalom, Rachel; Kuten, Abraham; Israel, Ora

    2007-01-01

    Purpose: To assess the value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in patients with nasopharyngeal carcinoma as compared with PET and conventional imaging (CI) alone, and to assess the impact of PET/CT on further clinical management. Methods and Materials: Thirty-three patients with nasopharyngeal carcinoma had 45 PET/CT examinations. The study was a retrospective analysis. Changes in patient care resulting from the PET/CT studies were recorded. Results: Positron emission tomography/computed tomography had sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 92%, 90%, 90%, 90%, and 91%, respectively, as compared with 92%, 65%, 76%, 86%, and 80% for PET and 92%, 15%, 60%, 60%, and 60% for CI. Imaging with PET/CT altered further management of 19 patients (57%). Imaging with PET/CT eliminated the need for previously planned diagnostic procedures in 11 patients, induced a change in the planned therapeutic approach in 5 patients, and guided biopsy to a specific metabolically active area inside an edematous region in 3 patients, thus decreasing the chances for tissue sampling errors and avoiding damage to nonmalignant tissue. Conclusions: In cancer of the nasopharynx, the diagnostic performance of PET/CT is better than that of stand-alone PET or CI. Positron emission tomography/computed tomography had a major impact on further clinical management in 57% of patients

  17. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  18. Gamma Imaging-Guided Minimally Invasive Breast Biopsy: Initial Clinical Experience.

    Science.gov (United States)

    Brem, Rachel F; Mehta, Anita K; Rapelyea, Jocelyn A; Akin, Esma A; Bazoberry, Adriana M; Velasco, Christel D

    2018-03-01

    The purpose of this study was to evaluate our initial experience with gamma imaging-guided vacuum-assisted breast biopsy in women with abnormal findings. A retrospective review of patients undergoing breast-specific gamma imaging (BSGI), also known as molecular breast imaging (MBI), between April 2011 and October 2015 found 117 nonpalpable mammographically and sonographically occult lesions for which gamma imaging-guided biopsies were recommended. Biopsy was performed with a 9-gauge vacuum-assisted device with subsequent placement of a titanium biopsy site marker. Medical records and pathologic findings were evaluated. Of the 117 biopsies recommended, 104 were successful and 13 were canceled. Of the 104 performed biopsies, 32 (30.8%) had abnormal pathologic findings. Of those 32 biopsies, nine (28.1%) found invasive cancers, six (18.8%) found ductal carcinoma in situ (DCIS), and 17 (53.1%) found high-risk lesions. Of the 17 high-risk lesions, there were three (17.6%) lobular carcinomas in situ, five (29.4%) atypical ductal hyperplasias, two (11.8%) atypical lobular hyperplasias, one (5.9%) flat epithelial atypia, and six (35.3%) papillomas. Two cases of atypical ductal hyperplasia were upgraded to DCIS at surgery. The overall cancer detection rate for gamma imaging-guided biopsy was 16.3%. In this study, gamma imaging-guided biopsy had a positive predictive value of total successful biopsies of 16.3% for cancer and 30.8% for cancer and high-risk lesions. Gamma imaging-guided biopsy is a viable approach to sampling BSGI-MBI-detected lesions without sonographic or mammographic correlate. Our results compare favorably to those reported for MRI-guided biopsy.

  19. Feasibility of Computed Tomography-Guided Methods for Spatial Normalization of Dopamine Transporter Positron Emission Tomography Image.

    Science.gov (United States)

    Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik

    2015-01-01

    Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD). We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.

  20. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  1. Technical note: CT-guided biopsy of lung masses using an automated guiding apparatus

    International Nuclear Information System (INIS)

    Chellathurai, Amarnath; Kanhirat, Saneej; Chokkappan, Kabilan; Swaminathan, Thiruchendur S; Kulasekaran, Nadhamuni

    2009-01-01

    Automated guiding apparatuses for CT-guided biopsies are now available. We report our experience with an indigenous system to guide lung biopsies. This system gave results similar to those with the manual technique. Automated planning also appears to be technically easier, it requires fewer number of needle passes, consumes less time, and requires fewer number of check scans

  2. Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

    Science.gov (United States)

    2018-01-01

    Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies. PMID:29169231

  3. Pericardial Tamponade Following CT-Guided Lung Biopsy

    International Nuclear Information System (INIS)

    Mitchell, Michael J.; Montgomery, Mark; Reiter, Charles G.; Culp, William C.

    2008-01-01

    While not free from hazards, CT-guided biopsy of the lung is a safe procedure, with few major complications. Despite its safety record, however, potentially fatal complications do rarely occur. We report a case of pericardial tamponade following CT-guided lung biopsy. Rapid diagnosis and therapy allowed for complete patient recovery. Physicians who perform this procedure should be aware of the known complications and be prepared to treat them appropriately.

  4. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  5. Cranial radiotherapy guided by computed tomography with or without fields conformation in pediatric

    International Nuclear Information System (INIS)

    Fernandez, Diego; Caussa, Lucas; Murina, Patricia; Zunino, Silvia

    2007-01-01

    Many malignancies in children can be cured by radiotherapy, acute toxicity and the significant effect of delayed treatment are worrying for the patient, family and society. Therefore, the end of the pediatric radiotherapy is to maintain or improve the cure rate of cancer, diminishing the aftermath of treatment. The goal of this study is to measure differences in doses to the healthy tissue of the central nervous system with two radiotherapy techniques, both guided by computed tomography [es

  6. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    Science.gov (United States)

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  7. BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    Science.gov (United States)

    Chen, Dong; Chen, Weisheng; Huang, Lipeng; Feng, Xuegang; Peters, Terry; Gu, Lixu

    2017-09-01

    Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biopsy with limited image resources. In this paper, we propose a patient-specific biomechanical model based on the boundary element method (BEM) computed from CT images to estimate the respiration motion of local target lesion region, vessel tree and lung surface for the real-time biopsy guidance. This approach applies pre-computation of various BEM parameters to facilitate the requirement for real-time lung motion simulation. The resulting boundary condition at end inspiratory phase is obtained using a nonparametric discrete registration with convex optimization, and the simulation of the internal tissue is achieved by applying a tetrahedron-based interpolation method depend on expert-determined feature points on the vessel tree model. A reference needle is tracked to update the simulated lung motion during biopsy guidance. We evaluate the model by applying it for respiratory motion estimations of ten patients. The average symmetric surface distance (ASSD) and the mean target registration error (TRE) are employed to evaluate the proposed model. Results reveal that it is possible to predict the lung motion with ASSD of [Formula: see text] mm and a mean TRE of [Formula: see text] mm at largest over the entire respiratory cycle. In the CT-/electromagnetic-guided biopsy experiment, the whole process was assisted by our BEM model and final puncture errors in two studies were 3.1 and 2.0 mm, respectively. The experiment results reveal that both the accuracy of simulation and real-time performance meet the demands of clinical biopsy guidance.

  8. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  9. The using of megavoltage computed tomography in image-guided brachytherapy for cervical cancer: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Tharavichitkul, Ekkasit; Janla-or, Suwapim; Wanwilairat, Somsak; Chakrabandhu, Somvilai; Klunklin, Pitchayaponne; Onchan, Wimrak; Supawongwattana, Bongkot; Chitapanarux, Imjai [Division of Therapeutic Radiology and Oncology, Dept. of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai (Thailand); Galalae, Razvan M. [Faculty of Medicine, Christian-Albrecht University (Campus Kiel), Kiel (Germany)

    2015-06-15

    We present a case of cervical cancer treated by concurrent chemoradiation. In radiation therapy part, the combination of the whole pelvic helical tomotherapy plus image-guided brachytherapy with megavoltage computed tomography of helical tomotherapy was performed. We propose this therapeutic approach could be considered in a curative setting in some problematic situation as our institution.

  10. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  11. Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Staging of Patients with Non-Small Cell Lung Cancer without Mediastinal Involvement at Positron Emission Tomography-Computed Tomography

    DEFF Research Database (Denmark)

    Naur, Therese Maria Henriette; Konge, Lars; Clementsen, Paul Frost

    2017-01-01

    BACKGROUND: Staging of lung cancer is essential to the treatment, which is curative only in cases of localized disease. Previous studies have suggested that endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unnecessary when positron emission tomography-computed tomog...

  12. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  13. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  14. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  15. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  16. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  17. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  18. Guided access cavity preparation using cone-beam computed tomography and optical surface scans - an ex vivo study

    DEFF Research Database (Denmark)

    Buchgreitz, J; Buchgreitz, M; Mortensen, D

    2016-01-01

    AIM: To evaluate ex vivo, the accuracy of a preparation procedure planned for teeth with pulp canal obliteration (PCO) using a guide rail concept based on a cone-beam computed tomography (CBCT) scan merged with an optical surface scan. METHODOLOGY: A total of 48 teeth were mounted in acrylic bloc...

  19. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ogo, Takeshi, E-mail: ogo.takeshi.hp@mail.ncvc.go.jp [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Department of Advanced Mediccal Research for Pulmonary Hypertension, National Cerebral and Cardiovascular Centre, Osaka (Japan); Fukuda, Tetsuya [Department of Radiology, National Cerebral and Cardiovascular Centre, Osaka (Japan); Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Sanda, Yoshihiro [Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Morita, Yoshiaki [Department of Radiology, National Cerebral and Cardiovascular Centre, Osaka (Japan); Asano, Ryotaro; Konagai, Nao [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Yasuda, Satoshi [Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan)

    2017-04-15

    Highlights: • Recent advancement in CT enables distal CTEpH lesions to be visualized. • We investigated the efficacy and safety of BPA guided by CBCT or ECG-gated area detector CT. • BPA guided by CBCT or ECG-gated area detector CT is effective and safe in patients with CTEpH . • These new advanced CT techniques may be useful in pre-BPA target lesion assessment. - Abstract: Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. Methods: We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1 year after BPA. Results: Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1 year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. Conclusions: BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment.

  20. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography

    International Nuclear Information System (INIS)

    Ogo, Takeshi; Fukuda, Tetsuya; Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin; Sanda, Yoshihiro; Morita, Yoshiaki; Asano, Ryotaro; Konagai, Nao; Yasuda, Satoshi

    2017-01-01

    Highlights: • Recent advancement in CT enables distal CTEpH lesions to be visualized. • We investigated the efficacy and safety of BPA guided by CBCT or ECG-gated area detector CT. • BPA guided by CBCT or ECG-gated area detector CT is effective and safe in patients with CTEpH . • These new advanced CT techniques may be useful in pre-BPA target lesion assessment. - Abstract: Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. Methods: We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1 year after BPA. Results: Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1 year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. Conclusions: BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment.

  1. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  2. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Oda, Miyo; Ito, Katsuhide

    2010-09-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: "none", "mild", "moderate" and "severe". The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p < 0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax.

  3. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method

    International Nuclear Information System (INIS)

    Kakizawa, Hideaki; Hieda, Masashi; Oda, Miyo; Toyota, Naoyuki; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Ito, Katsuhide

    2010-01-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: 'none', 'mild', 'moderate' and 'severe'. The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p<0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax. (author)

  4. Stereological measures of trabecular bone structure: comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies

    DEFF Research Database (Denmark)

    Thomsen, Jesper Skovhus; Laib, A.; Koller, B.

    2005-01-01

    Stereology applied on histological sections is the 'gold standard' for obtaining quantitative information on cancellous bone structure. Recent advances in micro computed tomography (microCT) have made it possible to acquire three-dimensional (3D) data non-destructively. However, before the 3D...... methods can be used as a substitute for the current 'gold standard' they have to be verified against the existing standard. The aim of this study was to compare bone structural measures obtained from 3D microCT data sets with those obtained by stereology performed on conventional histological sections...... tibial metaphysis. The biopsies were embedded in methylmetacrylate before microCT scanning in a Scanco microCT 40 scanner at a resolution of 20 x 20 x 20 microm3, and the 3D data sets were analysed with a computer program. After microCT scanning, 16 sections were cut from the central 2 mm of each biopsy...

  5. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Welch, B. T.; Eiken, P. W.; Atwell, T. D.; Peikert, T.; Yi, E. S.; Nichols, F.; Schmit, G. D.

    2017-01-01

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  6. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D. [Mayo Clinic, Department of Radiology (United States); Peikert, T. [Mayo Clinic, Department of Pulmonary and Critical Care Medicine (United States); Yi, E. S. [Mayo Clinic, Department of Pathology (United States); Nichols, F. [Mayo Clinic, Department of Thoracic Surgery (United States); Schmit, G. D. [Mayo Clinic, Department of Radiology (United States)

    2017-06-15

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  7. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS

    NARCIS (Netherlands)

    Futterer, J.J.; Moche, M.; Busse, H.; Yakar, D.

    2016-01-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and

  8. The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements

    Science.gov (United States)

    Raylman, Raymond R.; Majewski, Stan; Smith, Mark F.; Proffitt, James; Hammond, William; Srinivasan, Amarnath; McKisson, John; Popov, Vladimir; Weisenberger, Andrew; Judy, Clifford O.; Kross, Brian; Ramasubramanian, Srikanth; Banta, Larry E.; Kinahan, Paul E.; Champley, Kyle

    2008-02-01

    Tomographic breast imaging techniques can potentially improve detection and diagnosis of cancer in women with radiodense and/or fibrocystic breasts. We have developed a high-resolution positron emission mammography/tomography imaging and biopsy device (called PEM/PET) to detect and guide the biopsy of suspicious breast lesions. PET images are acquired to detect suspicious focal uptake of the radiotracer and guide biopsy of the area. Limited-angle PEM images could then be used to verify the biopsy needle position prior to tissue sampling. The PEM/PET scanner consists of two sets of rotating planar detector heads. Each detector consists of a 4 × 3 array of Hamamatsu H8500 flat panel position sensitive photomultipliers (PSPMTs) coupled to a 96 × 72 array of 2 × 2 × 15 mm3 LYSO detector elements (pitch = 2.1 mm). Image reconstruction is performed with a three-dimensional, ordered set expectation maximization (OSEM) algorithm parallelized to run on a multi-processor computer system. The reconstructed field of view (FOV) is 15 × 15 × 15 cm3. Initial phantom-based testing of the device is focusing upon its PET imaging capabilities. Specifically, spatial resolution and detection sensitivity were assessed. The results from these measurements yielded a spatial resolution at the center of the FOV of 2.01 ± 0.09 mm (radial), 2.04 ± 0.08 mm (tangential) and 1.84 ± 0.07 mm (axial). At a radius of 7 cm from the center of the scanner, the results were 2.11 ± 0.08 mm (radial), 2.16 ± 0.07 mm (tangential) and 1.87 ± 0.08 mm (axial). Maximum system detection sensitivity of the scanner is 488.9 kcps µCi-1 ml-1 (6.88%). These promising findings indicate that PEM/PET may be an effective system for the detection and diagnosis of breast cancer.

  9. The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); Majewski, Stan [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Proffitt, James [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Hammond, William [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Srinivasan, Amarnath [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); McKisson, John [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Judy, Clifford O [Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV (United States); Kross, Brian [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Ramasubramanian, Srikanth [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); Banta, Larry E [Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV (United States); Kinahan, Paul E [Department of Radiology, University of Washington, Seattle, WA (United States); Champley, Kyle [Department of Radiology, University of Washington, Seattle, WA (United States)

    2008-02-07

    Tomographic breast imaging techniques can potentially improve detection and diagnosis of cancer in women with radiodense and/or fibrocystic breasts. We have developed a high-resolution positron emission mammography/tomography imaging and biopsy device (called PEM/PET) to detect and guide the biopsy of suspicious breast lesions. PET images are acquired to detect suspicious focal uptake of the radiotracer and guide biopsy of the area. Limited-angle PEM images could then be used to verify the biopsy needle position prior to tissue sampling. The PEM/PET scanner consists of two sets of rotating planar detector heads. Each detector consists of a 4 x 3 array of Hamamatsu H8500 flat panel position sensitive photomultipliers (PSPMTs) coupled to a 96 x 72 array of 2 x 2 x 15 mm{sup 3} LYSO detector elements (pitch = 2.1 mm). Image reconstruction is performed with a three-dimensional, ordered set expectation maximization (OSEM) algorithm parallelized to run on a multi-processor computer system. The reconstructed field of view (FOV) is 15 x 15 x 15 cm{sup 3}. Initial phantom-based testing of the device is focusing upon its PET imaging capabilities. Specifically, spatial resolution and detection sensitivity were assessed. The results from these measurements yielded a spatial resolution at the center of the FOV of 2.01 {+-} 0.09 mm (radial), 2.04 {+-} 0.08 mm (tangential) and 1.84 {+-} 0.07 mm (axial). At a radius of 7 cm from the center of the scanner, the results were 2.11 {+-} 0.08 mm (radial), 2.16 {+-} 0.07 mm (tangential) and 1.87 {+-} 0.08 mm (axial). Maximum system detection sensitivity of the scanner is 488.9 kcps {mu}Ci{sup -1} ml{sup -1} (6.88%). These promising findings indicate that PEM/PET may be an effective system for the detection and diagnosis of breast cancer.

  10. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P. (Dept. of Spinal Surgery, Xian Red Cross Hospital, Xian Shaanxi (China)), email: zqpddn1@gmail.com; Sun, H.H. (Dept. of Orthopaedic, Tangdu Hospital, Fourth Military Medical Univ., Xian Shaanxi (China)); Jiang, Y.H. (Dept. of Radiology, Xian Red Cross Hospital, Xian Shaanxi (China))

    2011-11-15

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  11. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    International Nuclear Information System (INIS)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P.; Sun, H.H.; Jiang, Y.H.

    2011-01-01

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  12. Asymmetrically increased rib cage uptake on bone scintigraphy: Incidental detection of pleural mesothelioma on single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Dhull, Varun Singh; Sharma, Punit; Durgapal, Prashant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Follow-up bone scintigraphy (BS) in a patient of carcinoma left breast, who was treated with surgery followed by radiotherapy 12 years back, revealed asymmetrically increased radiotracer uptake in left-sided ribs. Since, this pattern was atypical for metastatic rib involvement, single photon emission computed tomography/computed tomography (SPECT/CT) of thorax was done in the same setting which revealed circumferential nodular left-sided pleural thickening. Biopsy confirmed it to be pleural mesothelioma. Left-sided ribs showed no abnormality on CT, thus suggesting the rib uptake as reactive in nature. This pattern of asymmetric rib uptake on BS should be kept in mind and warrants further investigation for determining underlying pathology

  13. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  14. Liver CT-guided aspirative biopsies

    International Nuclear Information System (INIS)

    Santos, Gilda da Cunha; Carvalho, Leda Viegas de; Chojniak, Rubens; Morini, Sandra Regina

    1996-01-01

    Sixty-eight CT-guided aspirative biopsies of hepatic nodules were performed at A.C. Camargo Hospital, Sao Paulo, Brazil, from 1992 to 1995. The cases were distributed as follow: 44(64.7%) with a positive diagnosis for neoplastic cells, 6(8.8%) with a negative diagnosis, and 14 (20.5%) with insufficient material. Of the positive cases (primary neoplasias and metastases), the cytological diagnosis was achieved in 39 cases. There were 36 cases of carcinoma (7 hepato carcinomas, 18 adenocarcinomas, 1 small cell carcinoma and 10 cases of unspecified differentiation), 2 cases of melanoma and 1 case of melanoma and 1 case of sarcoma. The correlation with histopathological exams showed no false positive cases and concordance between cytological and histopathological diagnosis. The results demonstrate that CT-guided aspirative biopsy of hepatic nodules permits a rapid diagnosis of neoplastic lesions, especially for the evaluation of metastases. (author)

  15. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  16. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    OpenAIRE

    Adel S. Ahmed; Mostafa I. Ragab; Alaa eldin M. Elgazaar; Nagwan A. Ismail

    2016-01-01

    Introduction: Pleural biopsy for pathological confirmation is the standard diagnostic procedure for pleural diseases, transthoracic ultrasonography (TUS) has evolved as an important imaging tool for diagnosing pleural and pulmonary conditions. Aim of the study: To assess the diagnostic yield of TUS guided pleural biopsy versus both CT guided and thoracoscopic pleural biopsy in the diagnosis of undiagnosed exudative pleural effusion. Patients and methods: The study was conducted at chest...

  17. Implementation of Upright Digital Breast Tomosynthesis-guided Stereotactic Biopsy.

    Science.gov (United States)

    Omofoye, Toma S; Martaindale, Sarah; Teichgraeber, Davis C; Parikh, Jay R

    2017-11-01

    With growing adoption of digital breast tomosynthesis, an increasing number of imaging abnormalities are being identified only by tomosynthesis. Upright digital breast tomosynthesis-guided stereotactic biopsy is a proven method for sampling these abnormalities as well as abnormalities traditionally evaluated using conventional stereotactic biopsy. In this article, we describe the technique of upright digital breast tomosynthesis-guided stereotactic biopsy and outline a systematic operational approach to implementation of this technique in clinical radiology practices. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  18. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  19. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  20. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  1. Utility of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in a child with chronic granulomatous disease

    International Nuclear Information System (INIS)

    Garg, Gunjan; DaSilva, Raphaella; Bhalakia, Avni; Milstein, David M.

    2016-01-01

    We report the fluorodeoxyglucose positron emission tomography/computed tomography (FDG - PET/CT) findings in an 11-month-old boy with suspected milk protein allergy, presented to the hospital with 2-month history of fever of unknown origin and failure to thrive. It showed FDG avid lymphadenopathy above and below the diaphragm and splenic focus, which could represent diffuse inflammatory process or lymphoma. Subsequent jejunal biopsy showed non-necrotizing granulomas

  2. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    International Nuclear Information System (INIS)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra; Muche, Rainer; Krueger, Stefan

    2008-01-01

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  3. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    Energy Technology Data Exchange (ETDEWEB)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra [University of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Muche, Rainer [University of Ulm, Institute of Biometrics, Ulm (Germany); Krueger, Stefan [University of Ulm, Department of Internal Medicine, Ulm (Germany)

    2008-06-15

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  4. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography.

    Science.gov (United States)

    Ogo, Takeshi; Fukuda, Tetsuya; Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin; Sanda, Yoshihiro; Morita, Yoshiaki; Asano, Ryotaro; Konagai, Nao; Yasuda, Satoshi

    2017-04-01

    Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1year after BPA. Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Application of a New Guiding System in Percutaneous Biopsies

    International Nuclear Information System (INIS)

    Petsas, Theodore; Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-01-01

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs

  6. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  7. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  8. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  9. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  10. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  11. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  12. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.

    2013-01-01

    Aim: To assess the accuracy and risk factors for complications of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for small (≤20 mm) pulmonary lesions. Materials and methods: A retrospective study was undertaken comprising 169 patients who underwent CT-guided CNB for small (≤20 mm) pulmonary lesions. To assess the accuracy of the procedure, the diagnosis at biopsy was compared with the diagnosis after definitive surgery or clinical follow-up. The risk factors for pneumothorax and bleeding were determined by multivariate analysis of variables. Results: The overall diagnostic accuracy was 93.5%. The sensitivity for malignancy and specificity for benign lesions were 90.4% and 100%, respectively. Positive and negative predictive values were 100% and 83.3%, respectively. Twenty-five patients (14.8%) had pneumothorax after CT percutaneous CNB of the lung. The significant risk factors affecting the incidence of pneumothorax were lesion–pleural distance (p = 0.008) and needle–pleural angle (p = 0.012). The highest rate of pneumothorax correlated with a lesion–pleural distance ≥21 mm (OR = 18.46; 95%CI: 2.27–149.95) and a needle–pleural angle ≥51° (OR = 8.22; 95%CI: 2.14–31.49). Bleeding occurred in 30 patients (17.8%). The only significant risk factor affecting the incidence of bleeding was lesion–pleural distance (p = 0.011). The highest bleeding rate correlated with a lesion–pleural distance ≥21 mm (OR = 7.93; 95%CI: 1.73–36.43). Conclusion: CT-guided percutaneous CNB of small (≤20 mm) pulmonary lesions provides high diagnostic accuracy with acceptable complications. A lesion–pleural distance of ≥21 mm and needle–pleural angle of ≥51° are identified as the risk factors for highest pneumothorax rate. In addition, the needle–pleural angle is a novel predictor of pneumothorax. A lesion–pleural distance of ≥21 mm is also identified as a risk factor for the highest bleeding rate.

  13. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  14. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik [Chungang Gil Hospital, Incheon (Korea, Republic of)

    1997-11-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US.

  15. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik

    1997-01-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US

  16. CT‑guided percutaneous transthoracic lung biopsy: First experience ...

    African Journals Online (AJOL)

    Percutaneous lung biopsy had been described in the nineteenth century by Leyden, but image- guided needle chest biopsy only gained widespread acceptance in the 1970s. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis cannot be obtained by the non-invasive techniques and cytological ...

  17. Three-dimensional computed tomography-guided monotherapeutic pararectal brachytherapy of prostate cancer with seminal vesicle invasion

    International Nuclear Information System (INIS)

    Koutrouvelis, Panos; Lailas, Niko; Hendricks, Fred; Gil-Montero, Guillermo; Sehn, James; Katz, Stuart

    2001-01-01

    Purpose: To treat patients with prostate cancer and seminal vesicle invasion with monotherapeutic three dimensional computed tomography (3-DCT)-guided posterior pararectal brachytherapy. Methods and materials: Three hundred and sixty two patients with clinical stage T1 a,b or T2 a,b of prostate cancer were referred for 3-DCT-guided brachytherapy. Each underwent further staging with 3-D CT-guided pararectal biopsy of the seminal vesicles under local anesthesia during the pre-treatment CT-planning. Forty-three patients (12%) were upstaged to T3 cNoMo disease. In the set of 43 patients, Eight had Gleason's score≤6, 24 Gleason's score=7, and 11 patients ≥8. Initial PSA was 20 in 18 patients. Of the 43 patients, 37 patients were treated monotherapeutically with 3-D CT-guided brachytherapy. No patients received hormone therapy after the implant. The prescribed dosage to the seminal vesicles and prostate is 120 Gy with Pd-103 seeds and 144 Gy with 1-125 seeds. Results: The prescribed dosage was achieved in all 37 patient's throughout the seminal vesicles whose range of target radiation extended 5-10 mm outside the target in the adjacent fat as calculated with post-implant CT-dosimetry with Varian Brachy Vision or MMS software. Prostate Specific Antigen (PSA) outcome data were available in 34 patients treated with monotherapy and follow up ranged from 12-56 months (median, 24 months). Decreased PSA levels were stratified into six groups based on the presenting Gleason's score and initial PSA. In the first group (with Gleason's score≤6 and initial PSA 20 ng/ml), PSA decreased to less than 0.5 ng/ml in four out of eight patients (50%). All of the patients in the fourth group (with Gleason's score≥8 and initial PSA 20 ng/ml). There were no patients with Gleason's score of 1-6 and greater than 20 ng/ml initial PSA. Patients, irrespective of the Gleason's score and PSA, had an overall response of decreased PSA (less than 1 ng/ml) of 79%. Conclusion: 3-D CT-guided

  18. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  19. CT-guided needle biopsy of lung lesions: A survey of severe complication based on 9783 biopsies in Japan

    International Nuclear Information System (INIS)

    Tomiyama, Noriyuki; Yasuhara, Yoshifumi; Nakajima, Yasuo; Adachi, Shuji; Arai, Yasuaki; Kusumoto, Masahiko; Eguchi, Kenji; Kuriyama, Keiko; Sakai, Fumikazu; Noguchi, Masayuki; Murata, Kiyoshi; Murayama, Sadayuki; Mochizuki, Teruhito; Mori, Kiyoshi; Yamada, Kozo

    2006-01-01

    Purpose: The aim of our study was to update the rate of severe complications following CT-guided needle biopsy in Japan via a mailed survey. Materials and methods: Postal questionnaires regarding CT-guided needle biopsy were sent out to multiple hospitals in Japan. The questions regarded: the total number and duration of CT-guided lung biopsies performed at each hospital, and the complication rates and numbers of pneumothorax, hemothorax, air embolism, tumor seeding, tension pneumothorax and other rare complications. Each severe complication was followed with additional questions. Results: Data from 9783 biopsies was collected from 124 centers. Pneumothorax was the most common complication, and occurred in 2412 (35%) of 6881 cases. A total of 39 (35%) hospitals reported 74 (0.75%) cases with severe complications. There were six cases (0.061%) with air embolism, six cases (0.061%) with tumor seeding at the site of the biopsy route, 10 cases (0.10%) with tension pneumothorax, six cases (0.061%) with severe pulmonary hemorrhage or hemoptysis, nine cases (0.092%) with hemothorax, and 27 cases (0.26%) with others, including heart arrest, shock, and respiratory arrest. From a total of 62 patients with severe complications, 54 patients (0.55%) recovered without sequela, however one patient (0.01%) recovered with hemiplegia due to cerebral infarction, and the remaining seven patients (0.07%) died. Conclusions: This is the first national study documenting severe complications with respect to CT-guided needle biopsy in Japan. The complication rate in Japan is comparable to internationally published figures. We believe this data will improve both clinicians as well as patients understanding of the risk versus benefit of CT-guided needle biopsy, resulting better decisions

  20. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  1. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  2. Computed tomography in opportunistic lung infections

    International Nuclear Information System (INIS)

    Hartelius, H.

    1988-01-01

    Chest radiography in two teenage boys, one with Wiscott-Aldrich's syndrome and one with acute lymphatic leucemia in remission showed increased interstitial pattern. In both computed tomography (CT) of the lungs showed heavy interstitial pneumonia, rather different in appearance but in both cases equal to the CT findings in opportunistic lung infections known from immunoincompetent patients with for instance pneumocystis carinii and/or cytomegalo virus infections. In both patients the CT findings led to lung biopsy establishing the etiologic agent. (orig.)

  3. MR-guided biopsies of lesions in the retroperitoneal space: technique and results

    International Nuclear Information System (INIS)

    Zangos, S.; Eichler, K.; Wetter, A.; Lehnert, T.; Hammerstingl, R.; Diebold, T.; Reichel, P.; Herzog, C.; Mack, M.G.; Vogl, T.J.; Hansmann, M.-L.

    2006-01-01

    The purpose of this study was to evaluate the safety and precision of MRI-guided biopsies of retroperitoneal space-occupying tumors in an open low-field system. In 30 patients with indistinct retroperitoneal tumors [paraaortic lesion (n=20), kidney (n=2), suprarenal gland (n=3) and pancreas (n=5)] MR-guided biopsies were performed using a low-field system (0.2 T, Magnetom Concerto, Siemens, Germany). For the monitoring of the biopsies T1-weighted FLASH sequences (TR/TE=160/5 ms; 90 ) were used in all patients and modified FLASH sequences (TR/TE=160/13 ms; 90 ) in ten patients. After positioning of the needle in the tumors 114 biopsy specimens were acquired in coaxial technique with 16-gauge cutting needles (Somatex, Germany). The biopsies were successfully performed in all patients without vascular or organ injuries. The visualization of the aortic blood flow with MRI facilitated the biopsy procedures of paraaortic lesions. The size of the lesions ranged from 1.6 to 7.5 cm. The median distance of the biopsy access path was 10.4 cm. Adequate specimens were obtained in 28 cases (93.3%) resulting in a correct histological classification of 27 lesions (90%). In conclusion, MR-guided biopsies of retroperitoneal lesions using an open low-field system can be performed safely and accurately and is an alternative to CT-guided biopsies. (orig.)

  4. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  5. PET/CT-guided biopsies of metabolically active bone lesions: applications and clinical impact

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, Bernd; Wartenberg, Jan; Weitzel, Thilo; Krause, Thomas [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); Wiskirchen, Jakub [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); University Hospital Tuebingen, Department of Radiology, Neuroradiology, and Nuclear Medicine, Tuebingen (Germany); Schmid, Ralph A. [Bern University Hospital and University of Bern, Department of Thoracic Surgery, Inselspital, Bern (Switzerland); Mueller, Michel D. [Bern University Hospital and University of Bern, Department of Obstetrics and Gynaecology, Inselspital, Bern (Switzerland)

    2010-11-15

    In a minority of cases a definite diagnosis and stage grouping in cancer patients is not possible based on the imaging information of PET/CT. We report our experience with percutaneous PET/CT-guided bone biopsies to histologically verify the aetiology of hypermetabolic bone lesions. We retrospectively reviewed the data of 20 consecutive patients who underwent multimodal image-guided bone biopsies using a dedicated PET/CT system in a step-by-step technique. Technical and clinical success rates of PET/CT-guided biopsies were evaluated. Questionnaires were sent to the referring physicians to assess the impact of biopsies on patient management and to check the clinical need for PET/CT-guided biopsies. Clinical indications for biopsy were to histologically verify the aetiology of metabolically active bone lesions without a morphological correlate confirming the suspicion of metastases in 15 patients, to determine the origin of suspected metastases in 3 patients and to evaluate the appropriateness of targeted therapy options in 2 patients. Biopsies were technically successful in all patients. In 19 of 20 patients a definite histological diagnosis was possible. No complications or adverse effects occurred. The result of PET/CT-guided bone biopsies determined a change of the planned treatment in overall 56% of patients, with intramodality changes, e.g. chemotherapy with palliative instead of curative intent, and intermodality changes, e.g. systemic therapy instead of surgery, in 22 and 50%, respectively. PET/CT-guided bone biopsies are a promising alternative to conventional techniques to make metabolically active bone lesions - especially without a distinctive morphological correlate - accessible for histological verification. PET/CT-guided biopsies had a major clinical impact in patients who otherwise cannot be reliably stage grouped at the time of treatment decisions. (orig.)

  6. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  7. CT-guided biopsy: diagnostic relevance, therapeutic consequences and economic aspects

    International Nuclear Information System (INIS)

    Schwarzenberg, H.; Mueller-Huelsbeck, S.; Link, J.; Brossmann, J.; Fahl, M.; Quirin, A.; Heller, M.

    1996-01-01

    Purpose: To evaluate the diagnostic and clinical relevance and therapeutic consequences of CT-guided biopsy with regard to economic aspects. Methods: 213 CT-guided biopsies in 190 were evaluated. All information regarding patient referral, reason for request, body region, underlying diagnosis, and clinical consequences were registered over a period of 22.2±9.4 month. Results: Patient referral to biopsy was mainly from the departments of surgery, internal medicine, and radiotherapy with the question of tumor and metastasis. Less than 5% of biopsies were performed in outpatients. Main regions were the lung (39%), the abdomen (35%), and the skeleton (11%). Biopsy and surgical histology corresponded in 73%. Largest diagnosis groups were benign unspecific tissues or other benign lesions in 24%. As a result of CTP no further procedures necessary in 22.5%. Follow-up studies or conservative treatment were indicated in 11.3%. Surgical procedures were needed in only 15.5%. There was only one complication requiring therapy. Conclusion: CT-guided biopsy is a safe procedure, which helps to avoid unnecessary cost-intensive diagnostics and surgical treatment. If CTP is performed early and in outpatients residence time in the hospital is reduced and thus money is saved. (orig.) [de

  8. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  9. Sono-Guided Percutaneous Automated Gun Biopsy in Pediatric Renal Disease

    International Nuclear Information System (INIS)

    Kim, Jong Chul

    1996-01-01

    To evaluate whether sono-guided percutaneous automated gun biopsy is also useful in pediatricpatients with renal diseases. In the prone position of twenty pediatric patients with renal parenchymal diseases, percutaneous biopsy was done through lateral aspect of the lower pole of left kidney with automated biopsy gun under the guidance of ultrasonography. The biopsy needle was either of 18 or 20 gauge. The obtained core of renal tissue was examined with light, immunofluorescent or electron microscope by the renal pathologist. In 18 among 20 patients, adequate renal tissue core sufficient to be pathologically diagnosed was obtained. The histologic findings were as follows : IG A nephropathy (n = 2), lupus nephritis (n =2), minimal change glomerulonephritis (n = 5), membranoproliferative glomerulonephritis (n = 3), mesangialproliferative glomeru-lonephritis (n = 1), diffuse proliferative glomerulonephritis (n = 3), focalglomerulo-sclerosis (n = 1), membranous glomerulopathy (n = 1). No significant complications occurred during or after the biopsy. Sono-guided percutaneous renal biopsy using automated biopsy gun is also useful todiagnose renal parenchymal diseases without significant complications in pediatric patients

  10. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  11. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  12. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  13. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  14. A case of lung abscess successfully treated by transbronchial drainage using a guide sheath

    OpenAIRE

    Izumi, Hiroki; Kodani, Masahiro; Matsumoto, Shingo; Kawasaki, Yuji; Igishi, Tadashi; Shimizu, Eiji

    2017-01-01

    A 51?year?old man was diagnosed with colon cancer in September 2011, and a solitary pulmonary nodule was detected by computed tomography (CT) scan. We performed a transbronchial biopsy with endobronchial ultrasonography using a guide sheath (GS) and diagnosed lung metastasis of colon cancer. The patient experienced remittent fever after the biopsy in spite of intravenous antibiotic therapies. Moreover, his CT scan showed a large lung abscess at the biopsy site. We performed transbronchial dra...

  15. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Development of a guidance guide for dosimetry in computed tomography; Desenvolvimento de um guia orientativo para dosimetria em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Fontes, Ladyjane Pereira

    2016-07-01

    Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR. (author)

  17. Computed-tomography-guided anatomic standardization for quantitative assessment of dopamine transporter SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kota [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Imabayashi, Etsuko; Matsuda, Hiroshi [National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Sumida, Kaoru; Sone, Daichi; Kimura, Yukio; Sato, Noriko [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); Mukai, Youhei; Murata, Miho [National Center of Neurology and Psychiatry, Department of Neurology, Tokyo (Japan)

    2017-03-15

    For the quantitative assessment of dopamine transporter (DAT) using [{sup 123}I]FP-CIT single-photon emission computed tomography (SPECT) (DaTscan), anatomic standardization is preferable for achieving objective and user-independent quantification of striatal binding using a volume-of-interest (VOI) template. However, low accumulation of DAT in Parkinson's disease (PD) would lead to a deformation error when using a DaTscan-specific template without any structural information. To avoid this deformation error, we applied computed tomography (CT) data obtained using SPECT/CT equipment to anatomic standardization. We retrospectively analyzed DaTscan images of 130 patients with parkinsonian syndromes (PS), including 80 PD and 50 non-PD patients. First we segmented gray matter from CT images using statistical parametric mapping 12 (SPM12). These gray-matter images were then anatomically standardized using the diffeomorphic anatomical registration using exponentiated Lie algebra (DARTEL) algorithm. Next, DaTscan images were warped with the same parameters used in the CT anatomic standardization. The target striatal VOIs for decreased DAT in PD were generated from the SPM12 group comparison of 20 DaTscan images from each group. We applied these VOIs to DaTscan images of the remaining patients in both groups and calculated the specific binding ratios (SBRs) using nonspecific counts in a reference area. In terms of the differential diagnosis of PD and non-PD groups using SBR, we compared the present method with two other methods, DaTQUANT and DaTView, which have already been released as software programs for the quantitative assessment of DaTscan images. The SPM12 group comparison showed a significant DAT decrease in PD patients in the bilateral whole striatum. Of the three methods assessed, the present CT-guided method showed the greatest power for discriminating PD and non-PD groups, as it completely separated the two groups. CT-guided anatomic standardization using

  18. Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Sedlmair, Martin; Ritter, Christine; Banckwitz, Rosemarie; Flohr, Thomas

    2012-01-01

    Purpose: Computed tomography (CT) fluoroscopy-guided interventions pose relevant radiation exposure to the interventionalist. The goal of this study was to analyze the efficacy of lower-body shielding as a simple structural method for decreasing radiation dose to the interventionalist without limiting access to the patient. Material and Methods: All examinations were performed with a 128-slice dual source CT scanner (12 × 1.2-mm collimation; 120 kV; and 20, 40, 60, and 80 mAs) and an Alderson-Rando phantom. Scatter radiation was measured with an ionization chamber and a digital dosimeter at standardized positions and heights with and without a lower-body lead shield (0.5-mm lead equivalent; Kenex, Harlow, UK). Dose decreases were computed for the different points of measurement. Results: On average, lower-body shielding decreased scatter radiation by 38.2% within a 150-cm radius around the shielding. This decrease is most significant close to the gantry opening and at low heights of 50 and 100 cm above the floor with a maximum decrease of scatter radiation of 95.9% close to the scanner’s isocentre. With increasing distance to the gantry opening, the effect decreased. There is almost no dose decrease effect at ≥150 above the floor. Scatter radiation and its decrease were linearly correlated with the tube current-time product (r 2 = 0.99), whereas percent scatter radiation decrease was independent of the tube current-time product. Conclusion: Lower-body shielding is an effective way to decrease radiation exposure to the interventionalist and should routinely be used in CT fluoroscopy-guided interventions.

  19. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  20. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Schouten, Martijn G. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); University Medical Centre Nijmegen, Department of Radiology, Nijmegen (Netherlands); Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Rothgang, Eva [Pattern Recognition Lab, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Center for Applied Medical Imaging, Siemens Corporate Research (Germany); Center for Applied Medical Imaging, Siemens Corporate Research, Baltimore, MD (United States); Misra, Sarthak [University of Twente, MIRA-Institute of Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2012-02-15

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  1. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    International Nuclear Information System (INIS)

    Schouten, Martijn G.; Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J.; Rothgang, Eva; Misra, Sarthak

    2012-01-01

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  2. The contribution of CT-guided transthoracic lung biopsy to the diagnosis of organising pneumonia.

    Science.gov (United States)

    Metzger, F; Pernet, D; Manzoni, P; Ranfaing, E; Dalphin, J-C

    2010-09-01

    Organising pneumonia is a pulmonary disease with variable clinical and radiological features and with many differential diagnoses. Diagnosis is based on histology obtained by either transbronchial or surgical lung biopsy but these techniques have several disadvantages. The aim of this study was to evaluate the diagnostic yield of CT-guided transthoracic lung biopsy in organising pneumonia and to compare it to the usual diagnostic tools. Six cases of organising pneumonia diagnosed with CT-guided lung biopsy are reported and discussed. The role of CT-guided lung biopsy in the diagnosis of organising pneumonia was also reviewed in the literature. CT-guided transthoracic lung biopsies provided a higher rate of adequate samples than transbronchial biopsies (92-100% versus 77-86%). The samples were larger, which reduced the risks of misdiagnosis and increased the diagnostic yield (88-97% versus 26-55% in pulmonary nodules and 42-100% versus 66-75% in diffuse pulmonary disease). Complications were rare and generally not serious. CT-guided transthoracic lung biopsy may be considered in place of transbronchial biopsy in the diagnosis of organising pneumonia. Surgical lung biopsy remains the gold standard method for diagnosis. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  3. The predictive value of single-photon emission computed tomography/computed tomography for sentinel lymph node localization in head and neck cutaneous malignancy.

    Science.gov (United States)

    Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S

    2015-04-01

    Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Scan-guided fine needle aspiration biopsy in malignant hepatic disease

    International Nuclear Information System (INIS)

    Johansen, P.; Svendsen, K.N.

    1978-01-01

    The method of scan-guided fine needle aspiration biopsy of the liver is described, and the diagnostic value of this combined method in the diagnosis of malignant hepatic disease is evaluated in 83 confirmed cases, showing a specificity of 100% and a sensitivity of 94%. The combined method is compared to liver scanning alone and to Menghini biopsy. Different methods for the diagnosis of malignant hepatic disease are discussed, and it is concluded that scan-guided fine needle aspiration biopsy has a diagnostic value only obtainable otherwise by a combination of liver scanning and biopsy during laparoscopy. Cytologic features in the two most common tumor types in this study, i.e., metastatic colonic adenocarcinoma and hepatocarcinoma, are presented along with a brief discussion of the specificity of the cytologic diagnosis of hepatocarcinoma

  5. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  6. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  7. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  8. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Science.gov (United States)

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  9. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  10. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    International Nuclear Information System (INIS)

    Vandervelde, C.; Kamani, T.; Varghese, A.; Ramesar, K.; Grace, R.; Howlett, D.C.

    2008-01-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status

  11. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Vandervelde, C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: clivevandervelde@gmail.com; Kamani, T. [Department of ENT Surgery, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: tkamany@yahoo.com; Varghese, A. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: vargheseajay@hotmail.com; Ramesar, K. [Department of Histopathology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: keith.ramesar@esht.nhs.uk; Grace, R. [Department of Haematology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: richard.grace@esht.nhs.uk; Howlett, D.C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: david.howlett@esht.nhs.uk

    2008-04-15

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  12. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  13. Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods

    International Nuclear Information System (INIS)

    Cho, Nariya; Moon, Woo Kyung; Cha, Joo Hee

    2005-01-01

    To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n=24), the imaging-histologic discordance (n=5), and the imaging findings showing disease progression (n=20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (ρ = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. The outcomes of the

  14. Efficacy of computed tomography guided radiofrequency ablation forosteoid osteomas in 31 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon; Ahn, Joong Mo; Lee, Joon Woo; Lee, Guen Young; Lee, Eu Gene; Oh, Joo Han; Cho, Hwan Seong; Kang, Heung Sik [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-04-15

    To present the clinical outcome of computed tomography (CT) guided radiofrequency ablation (RFA) for osteoid osteoma. Thirty-one patients (M:F = 23:8, mean age: 20 years, range: 4-54 years) who underwent RFA for clinically suspected osteoid osteoma from May 2004 to December 2013 were retrospectively reviewed. RFA was done in all cases under CT guidance by one of three radiologists in our department. Electronic medical records and images were retrospectively reviewed in all patients. Lesions were located in femur (n = 20), tibia (n = 5), fibula (n = 2), humerus (n = 3), talus (n = 2), and calcaneus (n = 1). On discharge, 27 of 33 cases showed complete remission of pain (82%). One major complication (compartment syndrome) and 2 minor complications (reactive synovitis, minimal skin burn at electrode insertion site) were observed. On the last follow-up (0-78 months, mean: 12.6 months) 27 of 33 cases were successfully treated (82%) and had no more complaints. 3 cases presented remaining pain (9%). In 3 cases relapse occurred (9%) and RFA was repeated in 1 case. The repeated treatment was successful. CT-guided RFA is an effective method for the treatment of osteoid osteoma.

  15. Ultrasonography-guided Transthoracic Cutting Biopsy of Pulmonary Lesion: Diagnostic Benefits and Safety

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Mei Ah; Park, Mi Hyun [Dankook University Hospital, Cheonan (Korea, Republic of); Shin, Byung Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Ohm, Joon Young [Bucheon St. Mary' s Hospital, Bucheon (Korea, Republic of)

    2012-06-15

    To assess the safety and usefulness of ultrasonography-guided transthoracic cutting biopsy for lung lesions. Eighty-eight patients (66 men, 22 women, mean age 59 years) with lung lesions underwent an ultrasonography(USG)-guided transthoracic cutting biopsy. The final diagnosis was based on the findings of surgery and clinical and radiological follow-ups. The histopathologic results and diagnostic accuracy of cutting biopsy were determined. Also, the complication rate was statistically evaluated according to the mass size, number of biopsies, and the presence or absence of pleural effusion. Biopsy specimens were successfully obtained in all patients. 79 of 88 lesions (89.8%) were established by histopathology. The final diagnosis was malignant in 58 and benign in 28. The remaining 2 patients were lost to follow-up. Diagnostic sensitivity for malignant lesions was 89.6% (52/58) and that for benign lesions was 96.4% (27/28). Procedure-related complications occurred in 9 patients (10.2%) including pneumothorax (n = 2) and hemoptysis (n = 7). And there was no significant difference according to mass size, number of biopsies, or presence of pleural effusion. USG-guided transthoracic cutting biopsy is a useful and safe method for technically-feasible lung lesions

  16. Ultrasonography-guided Transthoracic Cutting Biopsy of Pulmonary Lesion: Diagnostic Benefits and Safety

    International Nuclear Information System (INIS)

    Yang, Mei Ah; Park, Mi Hyun; Shin, Byung Seok; Ohm, Joon Young

    2012-01-01

    To assess the safety and usefulness of ultrasonography-guided transthoracic cutting biopsy for lung lesions. Eighty-eight patients (66 men, 22 women, mean age 59 years) with lung lesions underwent an ultrasonography(USG)-guided transthoracic cutting biopsy. The final diagnosis was based on the findings of surgery and clinical and radiological follow-ups. The histopathologic results and diagnostic accuracy of cutting biopsy were determined. Also, the complication rate was statistically evaluated according to the mass size, number of biopsies, and the presence or absence of pleural effusion. Biopsy specimens were successfully obtained in all patients. 79 of 88 lesions (89.8%) were established by histopathology. The final diagnosis was malignant in 58 and benign in 28. The remaining 2 patients were lost to follow-up. Diagnostic sensitivity for malignant lesions was 89.6% (52/58) and that for benign lesions was 96.4% (27/28). Procedure-related complications occurred in 9 patients (10.2%) including pneumothorax (n = 2) and hemoptysis (n = 7). And there was no significant difference according to mass size, number of biopsies, or presence of pleural effusion. USG-guided transthoracic cutting biopsy is a useful and safe method for technically-feasible lung lesions

  17. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    Science.gov (United States)

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  18. Computer Simulation Surgery for Mandibular Reconstruction Using a Fibular Osteotomy Guide

    Directory of Open Access Journals (Sweden)

    Woo Shik Jeong

    2014-09-01

    Full Text Available In the present study, a fibular osteotomy guide based on a computer simulation was applied to a patient who had undergone mandibular segmental ostectomy due to oncological complications. This patient was a 68-year-old woman who presented to our department with a biopsy-proven squamous cell carcinoma on her left gingival area. This lesion had destroyed the cortical bony structure, and the patient showed attenuation of her soft tissue along the inferior alveolar nerve, indicating perineural spread of the tumor. Prior to surgery, a three-dimensional computed tomography scan of the facial and fibular bones was performed. We then created a virtual computer simulation of the mandibular segmental defect through which we segmented the fibular to reconstruct the proper angulation in the original mandible. Approximately 2-cm segments were created on the basis of this simulation and applied to the virtually simulated mandibular segmental defect. Thus, we obtained a virtual model of the ideal mandibular reconstruction for this patient with a fibular free flap. We could then use this computer simulation for the subsequent surgery and minimize the bony gaps between the multiple fibular bony segments.

  19. Adaptation of a 3D prostate cancer atlas for transrectal ultrasound guided target-specific biopsy

    International Nuclear Information System (INIS)

    Narayanan, R; Suri, J S; Werahera, P N; Barqawi, A; Crawford, E D; Shinohara, K; Simoneau, A R

    2008-01-01

    Due to lack of imaging modalities to identify prostate cancer in vivo, current TRUS guided prostate biopsies are taken randomly. Consequently, many important cancers are missed during initial biopsies. The purpose of this study was to determine the potential clinical utility of a high-speed registration algorithm for a 3D prostate cancer atlas. This 3D prostate cancer atlas provides voxel-level likelihood of cancer and optimized biopsy locations on a template space (Zhan et al 2007). The atlas was constructed from 158 expert annotated, 3D reconstructed radical prostatectomy specimens outlined for cancers (Shen et al 2004). For successful clinical implementation, the prostate atlas needs to be registered to each patient's TRUS image with high registration accuracy in a time-efficient manner. This is implemented in a two-step procedure, the segmentation of the prostate gland from a patient's TRUS image followed by the registration of the prostate atlas. We have developed a fast registration algorithm suitable for clinical applications of this prostate cancer atlas. The registration algorithm was implemented on a graphical processing unit (GPU) to meet the critical processing speed requirements for atlas guided biopsy. A color overlay of the atlas superposed on the TRUS image was presented to help pick statistically likely regions known to harbor cancer. We validated our fast registration algorithm using computer simulations of two optimized 7- and 12-core biopsy protocols to maximize the overall detection rate. Using a GPU, patient's TRUS image segmentation and atlas registration took less than 12 s. The prostate cancer atlas guided 7- and 12-core biopsy protocols had cancer detection rates of 84.81% and 89.87% respectively when validated on the same set of data. Whereas the sextant biopsy approach without the utility of 3D cancer atlas detected only 70.5% of the cancers using the same histology data. We estimate 10-20% increase in prostate cancer detection rates

  20. The effect of ultrasound-guided compression immediately after transrectal ultrasound-guided prostate biopsy on postbiopsy bleeding: a randomized controlled pilot study.

    Science.gov (United States)

    Park, Bong Hee; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Han, Chang Hee

    2017-08-01

    To evaluate whether ultrasound-guided compression performed immediately after transrectal ultrasound (TRUS)-guided prostate biopsy decreases bleeding complications. We prospectively evaluated a total of 148 consecutive patients who underwent TRUS-guided prostate biopsy between March 2015 and July 2016. Systematic 12-core prostate biopsy was performed in all patients. Of these, 100 patients were randomly assigned to one of two groups: the compression group (n = 50) underwent TRUS-guided compression on bleeding biopsy tracts immediately after prostate biopsy, while the non-compression group (n = 50) underwent TRUS-guided prostate biopsy alone. The incidence rate and duration of hematuria, hematospermia, and rectal bleeding were compared between the two groups. The incidence rates of hematuria and hematospermia were not significantly different between the two groups (60 vs. 64%, p = 0.68; 22 vs. 30%, p = 0.362, respectively, for compression vs. non-compression group). The rectal bleeding incidence was significantly lower in the compression group as compared to the non-compression group (20 vs. 44%, p = 0.01). However, there were no significant differences in the median duration of hematuria, hematospermia, or rectal bleeding between the two groups (2, 8, and 2 days vs. 2, 10, and 1 days, p > 0.05, respectively, for compression vs. non-compression group). TRUS-guided compression [p = 0.004, odds ratio (OR) 0.25] and patient age (p = 0.013, OR 0.93) were significantly protective against the occurrence of rectal bleeding after prostate biopsy in multivariable analysis. Although it has no impact on other complications, ultrasound-guided compression on bleeding biopsy tracts performed immediately after TRUS-guided prostate biopsy is an effective and practical method to treat or decrease rectal bleeding.

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  2. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Si Yoon; Kwon, Jong Won [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-11-15

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect.

  3. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    International Nuclear Information System (INIS)

    Sung, Si Yoon; Kwon, Jong Won

    2015-01-01

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect

  4. PET/CT-guided percutaneous liver mass biopsies and ablations: Targeting accuracy of a single 20 s breath-hold PET acquisition

    International Nuclear Information System (INIS)

    Shyn, P.B.; Tatli, S.; Sahni, V.A.; Sadow, C.A.; Forgione, K.; Mauri, G.; Morrison, P.R.; Catalano, P.J.; Silverman, S.G.

    2014-01-01

    Aim: To determine whether a single 20 s breath-hold positron-emission tomography (PET) acquisition obtained during combined PET/computed tomography (CT)-guided percutaneous liver biopsy or ablation procedures has the potential to target 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG)-avid liver masses as accurately as up to 180 s breath-hold PET acquisitions. Materials and methods: This retrospective study included 10 adult patients with 13 liver masses who underwent FDG PET/CT-guided percutaneous biopsies (n = 5) or ablations (n = 5). PET was acquired as nine sequential 20 s, monitored, same-level breath-hold frames and CT was acquired in one monitored breath-hold. Twenty, 40, 60, and 180 s PET datasets were reconstructed. Two blinded readers marked tumour centres on randomized PET and CT datasets. Three-dimensional spatial localization differences between PET datasets and either 180 s PET or CT were analysed using multiple regression analyses. Statistical tests were two-sided and p < 0.05 was considered significant. Results: Targeting differences between 20 s PET and 180 s PET ranged from 0.7–20.3 mm (mean 5.3 ± 4.4 mm; median 4.3) and were not statistically different from 40 or 60 s PET (p = 0.74 and 0.91, respectively). Targeting differences between 20 s PET and CT ranged from 1.4–36 mm (mean 9.6 ± 7.1 mm; median 8.2 mm) and were not statistically different from 40, 60, or 180 s PET (p = 0.84, 0.77, and 0.35, respectively). Conclusion: Single 20 s breath-hold PET acquisitions from PET/CT-guided percutaneous liver procedures have the potential to target FDG-avid liver masses with equivalent accuracy to 180 s summed, breath-hold PET acquisitions and may facilitate strategies that improve image registration and shorten procedure times

  5. Complications and risk factors in transrectal ultrasound-guided prostate biopsies

    Directory of Open Access Journals (Sweden)

    Carlos Márcio Nóbrega de Jesus

    Full Text Available CONTEXT AND OBJECTIVE: Prostate biopsy is not a procedure without risk. There is concern about major complications and which antibiotics are best for routine use before these biopsies. The objective was to determine the rate of complications and the possible risk factors in prostate biopsies. DESIGN AND SETTING: Prospective study, Faculdade de Medicina de Botucatu. METHODS: Transrectal ultrasound (TRUS guided prostate biopsies were carried out in 174 patients presenting either abnormality in digital rectal examinations (DRE or levels higher than 4 ng/ml in prostate-specific antigen (PSA tests, or both. RESULTS: Hemorrhagic complications were the most common (75.3%, while infectious complications occurred in 19% of the cases. Hematuria was the most frequent type (56%. Urinary tract infection (UTI occurred in 16 patients (9.2%. Sepsis was observed in three patients (1.7%. The presence of an indwelling catheter was a risk factor for infectious complications (p < 0.05. Higher numbers of biopsies correlated with hematuria, rectal bleeding and infectious complications (p < 0.05. The other conditions investigated did not correlate with post-biopsy complications. CONCLUSIONS: Post-biopsy complications were mostly self-limiting. The rate of major complications was low, thus showing that TRUS guided prostate biopsy was safe and effective. Higher numbers of fragments taken in biopsies correlated with hematuria, rectal bleeding and infectious complications. An indwelling catheter represented a risk factor for infectious complications. The use of aspirin was not an absolute contraindication for TRUS.

  6. US-guided diffuse optical tomography for breast lesions: the reliability of clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jung; Kim, Ji Youn; Youn, Jung Hyun; Kim, Myung Hyun; Koo, Hye Ryoung; Kim, Soo Jin; Sohn, Yu-Mee; Moon, Hee Jung; Kim, Eun-Kyung [Yonsei University College of Medicine, Institute of Radiological Science, Seoul (Korea, Republic of); Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2011-07-15

    To prospectively assess the reliability of US-guided diffuse optical tomography (US-DOT) using interobserver agreement for the diagnosis of breast lesions with individual real-time imaging and to assess the interobserver agreement of conventional sonography (US) combined with US-DOT for differentiation between benignity and malignancy breast lesions. An Institutional Review Board approved this study, and all subjects provided written informed consent. 122 breast lesions in 111 patients evaluated with US-guided core biopsy were included. Assessments with US and US-DOT for cases subjected to biopsy were obtained by two radiologists using individual real-time imaging prior to biopsy and were prospectively recorded by each performer. With DOT, the total haemoglobin concentration (THC) for each breast lesion was measured. Histopathological results from US-guided biopsies were used as a reference standard. To assess measurement interobserver agreement, the intraclass correlation coefficient (ICC) and the Bland-Altman plot were used for THC in US-DOT and the kappa values and ROC analysis were used to evaluate the diagnostic performances of the US BI-RADS final assessment in US and combined US and US-DOT. Of 122 US-guided core biopsied lesions, 83 (68.0%) were diagnosed as benign, and 39 (32.0%) as malignant. Excellent correlation was seen in the THC in US-DOT (ICC score 0.796; 95% confidence interval, 0.708-0.857). The interobserver agreement in BI-RADS final assessment with US and US-DOT (almost perfect; {kappa} = 0.8618) was improved compared with that of US (substantial agreement, {kappa} = 0.6574). However, the overall areas under the ROC curve did not show significant differences between US and combined US and US-DOT, 0.8894 and 0.8975, respectively (P = 0.981). The reliability of THC in US-DOT showed excellent correlation in overall real-time performance. Although the inter-observer agreement for BI-RADS final assessment of US was improved by using US-DOT, the

  7. PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan

    Energy Technology Data Exchange (ETDEWEB)

    Wong, K.; Rahill, J.; Cleary, K. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Petrillo, S.; Earl-Graef, D. [Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Banovac, F.; Levy, E. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Shekhar, R. [Dept. of Radiology, Univ. of Maryland Medical Center, Baltimore, MD (United States)

    2007-06-15

    Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

  8. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  9. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  10. Transbiliary intravascular ultrasound-guided diagnostic biopsy of an inaccessible pancreatic head mass

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2017-06-01

    Full Text Available Percutaneous image-guided biopsies of pancreatic malignancies may prove challenging and nondiagnostic due to a variety of anatomic considerations. For patients with complex post-surgical anatomy, such as a Roux-en-Y gastric bypass, diagnosis via endoscopic ultrasound with fine-needle aspiration may not be possible because of an inability to reach the proximal duodenum. This report describes the first diagnostic case of transbiliary intravascular ultrasound-guided biopsy of a pancreatic head mass in a patient with prior Roux-en-Y gastric bypass for which a diagnosis could not be achieved via percutaneous and endoscopic approaches. Transbiliary intravascular ultrasound-guided biopsy resulted in a diagnosis of pancreatic adenocarcinoma, allowing the initiation of chemotherapy.

  11. Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Schernthaner, M.; Helbich, T.H.; Fueger, B.J.; Memarsadeghi, M.; Stiglbauer, A.; Linhart, H.G.; Doan, A.; Pinker, K.; Brader, P.; Margreiter, M.

    2011-01-01

    In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy. (orig.) [de

  12. Computed tomography appearances of sclerosing encapsulating peritonitis

    International Nuclear Information System (INIS)

    George, C.; Al-Zwae, K.; Nair, S.; Cast, J.E.I.

    2007-01-01

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP

  13. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  14. Computed tomography-guided percutaneous catheter drainage of primary and secondary iliopsoas abscesses

    International Nuclear Information System (INIS)

    Cantasdemir, M.; Kara, B.; Cebi, D.; Selcuk, N.D.; Numan, F.

    2003-01-01

    AIM: To report our experience with computed tomography (CT)-guided percutaneous catheter drainage (PCD) of iliopsoas abscesses. MATERIALS AND METHODS: Twenty-two iliopsoas abscesses in 21 patients (11 women, 10 men) aged between 18 and 66 years (mean 36 years) were treated with PCD. Abdominal CT demonstrated the iliopsoas abscesses, which were definitively determined by Gram staining and aspirate cultures. Twenty of the 22 iliopsoas abscesses were primary and two were secondary. All PCD procedures were performed under local anaesthesia using a single-step trocar technique (n=19) or Seldinger technique (n=3). RESULTS: PCD was an effective treatment in 21 out of the 22 iliopsoas abscesses. Recurrence was seen in three abscesses as minimal residual collections. Two of them resolved spontaneously with anti-tuberculous regimen. One required percutaneous needle aspiration. The procedure failed in a diabetic patient with a secondary abscess, who died due to sepsis. The length of time that catheters remained in place ranged from 21 to 75 days (mean 59.7 days). Complications included catheter dislocation in four abscesses, which required removal of dislocated catheters and indwelling new ones. CONCLUSION: CT-guided PCD is a safe and effective front-line treatment of iliopsoas abscesses. Surgery should be reserved for failure of PCD and presence of contraindications to PCD

  15. Ultrasound-guided biopsy and drainage

    International Nuclear Information System (INIS)

    Ott, R.C.; Wellauer, J.

    1985-01-01

    This book discusses the ultrasound (US) biopsy techniques, cytology, histology, and physics. The emphasis is on use of US guidance, as the authors find that virtually all lesions are visible at US scanning and they thus save valuable time on the computer tomographic scanner. The authors present in great detail their considerable work in designing needles that are readily visible at US scanning and can also collect good cytologic and histologic material. Biopsy techniques are discussed separately for each organ system. The accuracy of these techniques in over 3,000 of the author's cases is presented

  16. Analysis of diagnositc accuracy with CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Haiyan; Zhuang Yiping; Zhang Jin; Feng Yong; Zhang Xiao; Xu Lin

    2007-01-01

    Objective: To evaluate the factors which may affect the diagnostic accmracy of CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions. Methods: CT-guided percutaneous transthoracic lung biopsy was performed in 264 patients, all of which were proved by surgical pathology or clinical follow-up. A logistic regression analysis was used to investigate the relationship between the location and the size of the lesions and insertion depth of biopsy needles and the diagnostic accuracy of CT-guided percutaneous transthomcic lung biopsy. The complication rate including pneumatothorax and bleeding rate were record. Results: The diagnostic accuracy was 87.5%. Both the pneumothorax and the bleeding of lesion were 1.9%. The size of lesion was suggested by Logistic regression analysis had a significant influence on the diagnostic accuracy (Wald=12.891, P=0.00034, OR=0.96). Conclusion: CT-guided pereumneous transthoracic lung biopsy has a high diagnostic accuracy for pulmonary lesions. The size of the lesions had significant effect on the diagnostic accuracy. (authors)

  17. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  18. Cost-effectiveness of MR Imaging-guided Strategies for Detection of Prostate Cancer in Biopsy-Naive Men.

    Science.gov (United States)

    Pahwa, Shivani; Schiltz, Nicholas K; Ponsky, Lee E; Lu, Ziang; Griswold, Mark A; Gulani, Vikas

    2017-10-01

    Purpose To evaluate the cost-effectiveness of multiparametric diagnostic magnetic resonance (MR) imaging examination followed by MR imaging-guided biopsy strategies in the detection of prostate cancer in biopsy-naive men presenting with clinical suspicion of cancer for the first time. Materials and Methods A decision-analysis model was created for biopsy-naive men who had been recommended for prostate biopsy on the basis of abnormal digital rectal examination results or elevated prostate-specific antigen levels (age groups: 41-50 years, 51-60 years, and 61-70 years). The following three major strategies were evaluated: (a) standard transrectal ultrasonography (US)-guided biopsy; (b) diagnostic MR imaging followed by MR imaging-targeted biopsy, with no biopsy performed if MR imaging findings were negative; and (c) diagnostic MR imaging followed by MR imaging-targeted biopsy, with a standard biopsy performed when MR imaging findings were negative. The following three MR imaging-guided biopsy strategies were further evaluated in each MR imaging category: (a) biopsy with cognitive guidance, (b) biopsy with MR imaging/US fusion guidance, and (c) in-gantry MR imaging-guided biopsy. Model parameters were derived from the literature. The primary outcome measure was net health benefit (NHB), which was measured as quality-adjusted life-years (QALYs) gained or lost by investing resources in a new strategy compared with a standard strategy at a willingness-to-pay (WTP) threshold of $50 000 per QALY gained. Probabilistic sensitivity analysis was performed by using Monte Carlo simulations. Results Noncontrast MR imaging followed by cognitively guided MR biopsy (no standard biopsy if MR imaging findings were negative) was the most cost-effective approach, yielding an additional NHB of 0.198 QALY compared with the standard biopsy approach. Noncontrast MR imaging followed by in-gantry MR imaging-guided biopsy (no standard biopsy if MR imaging findings were negative) led to the

  19. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences; Evaluierung einer neuen Seldinger-Nadel fuer computertomografisch gesteuerte Interventionen: Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Plumhans, C.; Mahnken, A.; Iwa, R.; Behrendt, F.F.; Sebastian, K.; Guenther, R.W.; Honnef, D. [Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2009-02-15

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 {+-} 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  20. Comparison of plain radiography, conventional tomography, and computed tomography in detecting intrathoracic lymph node metastases from lung carcinoma

    International Nuclear Information System (INIS)

    Osborne, D.R.; Korobkin, M.; Ravin, C.E.

    1982-01-01

    Forty-two patients with T2 bronchogenic carcinoma were evaluated with plain radiography, conventional 55 0 oblique hilar and anteroposterior mediastinal tomography, and computed tomography (CT) to compare their accuracy in assessing mediastinal and hilar nodal metastases. Definitive staging was achieved by thoracotomy and histopathological evaluation of resected specimens. All modalities demonstrated about the same accuracy, however, in the 25 patients with hilar and/or mediastinal lymphadenopathy, CT of the mediastinum was more sensitive but not more specific than the other two and conventional tomography was no more accurate than CT for hilar evaluation. Overall, no technicue was accurate enough for routine staging; their value may lie in directing biopsy or in treatment planning in patients with inoperable disease

  1. Transrectal EUS-guided FNA biopsy of a presacral chordoma-report of a case and review of the literature

    Institute of Scientific and Technical Information of China (English)

    Klaus Gottlieb; Paul H Lin; David M Liu; Karl Anders

    2008-01-01

    Chordomas are rare tumors which originate from the remnants of the notochord.These tumors are locally aggressive and have a predilection for the ends of the axial skeleton.An important prerequisite for optimal management of these tumors is a correct preoperative diagnosis.The present case is the first report of the use of endoscopic ultrasound to obtain transrectal fine needle aspiration biopsy of a presacral chordoma.A review of the prior computer tomography (CT) scans allowed us to calculate the tumor volume doubling time (18.3 mo).Transrectal biopsy of chordomas is controversial,however we believe that such concerns are not justified.

  2. Sentinel Lymph Node Biopsy in Oral Cancer: Validation of Technique and Clinical Implications of Added Oblique Planar Lymphoscintigraphy and/or Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, J.B.; Soerensen, J.A.; Grupe, P.; Krogdahl, A. [Odense Univ. Hospital (Denmark). Depts. of Plastic and Reconstructive Surgery, Nuclear Medicine, and Pathology

    2005-10-01

    Purpose: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. Material and Methods: Forty patients (17 F and 23 M, aged 32-90) with 24 T1 and 16 T2 squamous cell carcinoma of the oral cavity. Planar lymphoscintigraphy, emission and transmission tomography were performed. Detection and excision of the sentinel nodes were guided by a gamma probe. The sentinel nodes were step-sectioning and stained with hematoxylin and eosin and cytokeratin (CK 1). Histology and follow-up were used as 'gold standard'. Tumor location, number of sentinel lymph nodes, metastasis, and recurrences were registered. Two observers evaluated the lymphoscintigraphic images to assess the inter-rater agreement. Results: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis ( P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel lymph node biopsy. Three patients developed a lymph node recurrence close to the primary tumor site during follow-up. Added oblique lymphoscintigraphic images and/or tomography revealed extra hotspots in 15/40 (38%) patients. In 4/40 (10%), extra contralateral hotspots were detected. Conclusion: Sentinel lymph node biopsy upstaged 28% of the patients. Sentinel lymph nodes close to the primary tumor were difficult to find. Added oblique planar images and/or tomographic images revealed extra clinical relevant hotspots in 38% of patients. Reproducibility proved excellent.

  3. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: An analysis for Austria

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, R., E-mail: renate.gruber@meduniwien.ac.a [Medical University of Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Walter, E. [Institute of Pharmacoeconomic Research, Wolfengasse 4/7, A-1010 Vienna (Austria); Helbich, T.H. [Medical University of Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2010-06-15

    Purpose: To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. Materials and methods: In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Results: Overall cost savings for US-guided LCBB over OSB were Euro 977 ( Euro 2,337/ Euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were Euro 1,542 ( Euro 2,600/ Euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. Conclusion: From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be Euro 18.5 million.

  4. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: An analysis for Austria

    International Nuclear Information System (INIS)

    Gruber, R.; Walter, E.; Helbich, T.H.

    2010-01-01

    Purpose: To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. Materials and methods: In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Results: Overall cost savings for US-guided LCBB over OSB were Euro 977 ( Euro 2,337/ Euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were Euro 1,542 ( Euro 2,600/ Euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. Conclusion: From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be Euro 18.5 million.

  5. High concordance of findings obtained from transgluteal magnetic resonance imaging - and transrectal ultrasonography-guided biopsy as compared with prostatectomy specimens.

    Science.gov (United States)

    Steurer, Stefan; Rico, Sebastian Dwertmann; Simon, Ronald; Minner, Sarah; Tsourlakis, Maria Christina; Krech, Till; Koop, Christina; Graefen, Markus; Heinzer, Hans; Adam, Meike; Huland, Hartwig; Schlomm, Thorsten; Sauter, Guido; Lumiani, Agron

    2017-09-01

    To determine the utility of our transgluteal magnetic resonance imaging (MRI)-guided prostate biopsy approach. A total of 960 biopsy series, taken within the period of 1 year, were evaluated, including 301 MRI-guided and 659 transrectal ultrasonography (TRUS)-guided biopsies. The positivity rate and proportion of high grade cancers were significantly higher in MRI-guided than in TRUS-guided biopsies. Of 301 MRI-guided biopsies, 65.4% contained cancer while 57.2% of 659 TRUS biopsies contained cancer (P = 0.016). Gleason grade 3 + 3 = 6 disease was observed in 16.8% of 197 MRI-guided and in 36.1% of 377 TRUS-guided biopsies (P guided biopsies. In all cancers, the mean cancer surface area was 64.8 ± 51.6 mm 2 in MRI-guided biopsies as compared with 23.0 ± 31.4 mm 2 in non-MRI-guided biopsies (P guided biopsy was highest in Gleason grade 3 + 3 = 6 cancers (20.9 ± 27.9 vs 5.1 ± 10.2 mm 2 ; P guided and in 170 patients with non-MRI-guided biopsies. This comparison showed a very high but almost identical concordance of TRUS- and MRI-guided biopsies with the prostatectomy specimen findings. With both approaches, undetected high-risk cancers were present in ~10% of patients with low-risk biopsy results. A significant difference was observed, however, in the proportion of patients who had clinically insignificant cancers and who underwent surgery. The proportion of patients with Gleason grade 3 + 3 = 6 carcinoma in their prostatectomy specimen was 11.2% in the post-TRUS biopsy cohort, but only 2.5% in the post-MRI biopsy cohort (P = 0.021). MRI-guided transgluteal prostate biopsy has a high detection rate for high-risk carcinomas, while the risk of detecting clinically insignificant carcinomas appears to be reduced. This may by itself lead to a reduction of unnecessary prostatectomies. Overtreatment may be further avoided by better applicability of molecular testing to MRI-guided biopsies because of the excessive amount of tissue available for analysis, especially in

  6. Automated tru-cut imaging-guided core needle biopsy of canine ...

    African Journals Online (AJOL)

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single ...

  7. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    International Nuclear Information System (INIS)

    Stattaus, Joerg; Kuehl, Hilmar; Ladd, Susanne; Schroeder, Tobias; Antoch, Gerald; Baba, Hideo A.; Barkhausen, Joerg; Forsting, Michael

    2007-01-01

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsies (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results

  8. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  9. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  10. Usefulness of the coaxial technique in US-guided breast core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok [Dongkang general hospital, Seoul (Korea, Republic of); Ham, Soo Youn [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-05-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells.

  11. Usefulness of the coaxial technique in US-guided breast core biopsy

    International Nuclear Information System (INIS)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok; Ham, Soo Youn

    1999-01-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells

  12. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  13. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  15. Efficacy and Complications of Ultrasound-Guided Percutaneous Renal Biopsy Using Automatic Biopsy Gun in Pediatric Diffuse Renal Disease: Analysis of 97 Cases

    International Nuclear Information System (INIS)

    Han, Seung Min; Chung, Tae Woong; Yoon, Woong

    2007-01-01

    To evaluate the diagnostic efficacy and complications of ultrasound-guided percutaneous renal biopsy using automatic biopsy gun in patients with pediatric diffuse renal disease. Using an 18G automatic biopsy gun, biopsies were performed on 97 pediatric patients with clinically suspicious diffuse renal disease. The acquired tissue specimens were analyzed by photomicroscopy, immunofluorescence, and electron microscopy to support the diagnosis. In the 97 biopsies, the success of the histologic diagnosis, number of glomeruli, and complication rates were retrospectively evaluated by analyzing the variable exams and clinical records. Adequate tissue for histologic diagnosis was obtained in 91 of 97 biopsies (94%) and the mean number of glomeruli was 9.6. Complications such as minute pain, gross hematuria, and small perirenal hematoma presented in 22 of the 97 biopsies (23%), all of which either improved within 5-72 hours or did not need specific treatment. Ultrasound-guided percutaneous renal biopsy using 18G automatic biopsy gun is an effective and safe method for the histologic diagnosis of pediatric diffuse renal disease without any major complication

  16. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    Science.gov (United States)

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  17. Use of 99mTc-sestamibi Single-photon Emission Computed Tomography / X-ray Computed Tomography in the Diagnosis of Hybrid Oncocytic / Chromophobe Tumor in a Pediatric Patient.

    Science.gov (United States)

    Almassi, Nima; Gorin, Michael A; Purysko, Andrei S; Rowe, Steven P; Kaouk, Jihad; Allaf, Mohamad E; Campbell, Steven C; Rhee, Audrey

    2018-03-01

    The differential diagnosis of solid renal neoplasms in adolescence includes aggressive malignancy and indolent oncocytic tumors, which are typically indistinguishable using conventional imaging. We report the use of 99m Tc-sestamibi single-photon emission computed tomography / x-ray computed tomography (SPECT/CT) in characterizing enhancing renal neoplasms in a pediatric patient. Genetic testing suggested a hereditary syndrome associated with aggressive malignancy, whereas renal mass biopsy suggested an oncocytic tumor. 99m Tc-sestamibi SPECT/CT indicated probable oncocytomas or hybrid oncocytic / chomophobe tumors. Enucleative resection was performed with final pathology demonstrating hybrid oncocytic / chomophobe tumors. This case highlights the potential utility of 99m Tc-sestamibi SPECT/CT in characterizing indeterminate enhancing renal neoplasm in pediatric patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: an analysis for Austria.

    Science.gov (United States)

    Gruber, R; Walter, E; Helbich, T H

    2010-06-01

    To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  19. Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

    Science.gov (United States)

    Brunner, Stephen; Nett, Brian E; Tolakanahalli, Ranjini; Chen, Guang-Hong

    2011-02-21

    X-ray scatter is a significant problem in cone-beam computed tomography when thicker objects and larger cone angles are used, as scattered radiation can lead to reduced contrast and CT number inaccuracy. Advances have been made in x-ray computed tomography (CT) by incorporating a high quality prior image into the image reconstruction process. In this paper, we extend this idea to correct scatter-induced shading artifacts in cone-beam CT image-guided radiation therapy. Specifically, this paper presents a new scatter correction algorithm which uses a prior image with low scatter artifacts to reduce shading artifacts in cone-beam CT images acquired under conditions of high scatter. The proposed correction algorithm begins with an empirical hypothesis that the target image can be written as a weighted summation of a series of basis images that are generated by raising the raw cone-beam projection data to different powers, and then, reconstructing using the standard filtered backprojection algorithm. The weight for each basis image is calculated by minimizing the difference between the target image and the prior image. The performance of the scatter correction algorithm is qualitatively and quantitatively evaluated through phantom studies using a Varian 2100 EX System with an on-board imager. Results show that the proposed scatter correction algorithm using a prior image with low scatter artifacts can substantially mitigate scatter-induced shading artifacts in both full-fan and half-fan modes.

  20. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  3. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach

    Directory of Open Access Journals (Sweden)

    Feng Mao

    2017-01-01

    Full Text Available Aim. To investigate the value of contrast-enhanced ultrasound (CEUS guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6 who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US guidance group (n=75. All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3% and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm nonenhanced necrotic areas. More inner (20.0% versus 6.7% and surrounding (18.3% versus 2.7% major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%. The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%. Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  4. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    Science.gov (United States)

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  5. Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies: An in-vitro study.

    Science.gov (United States)

    Lossnitzer, Dirk; Seitz, Sebastian A; Krautz, Birgit; Schnackenburg, Bernhard; André, Florian; Korosoglou, Grigorios; Katus, Hugo A; Steen, Henning

    2015-07-26

    To investigate if magnetic resonance (MR)-guided biopsy can improve the performance and safety of such procedures. A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5T magnetic resonance imaging (MRI) system. The bioptome was inserted into explanted porcine and bovine hearts under real-time MR-guidance employing a steady state free precession sequence. The artifact produced by the metal element at the tip and the signal voids caused by the bioptome were visually tracked for navigation and allowed its constant and precise localization. Cardiac structural elements and the target regions for the biopsy were clearly visible. Our method allowed a significantly better spatial visualization of the bioptoms tip compared to conventional X-ray guidance. The specific device design of the bioptome avoided inducible currents and therefore subsequent heating. The novel MR-compatible bioptome provided a superior cardiovascular magnetic resonance (imaging) soft-tissue visualization for MR-guided myocardial biopsies. Not at least the use of MRI guidance for endomyocardial biopsies completely avoided radiation exposure for both patients and interventionalists. MRI-guided endomyocardial biopsies provide a better than conventional X-ray guided navigation and could therefore improve the specificity and reproducibility of cardiac biopsies in future studies.

  6. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  7. Diagnostic Yield of Transbronchial Biopsy in Comparison to High Resolution Computerized Tomography in Sarcoidosis Cases

    Science.gov (United States)

    Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan

    2018-04-25

    This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License

  8. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shirvani, Shervin M.; Komaki, Ritsuko; Heymach, John V.; Fossella, Frank V.; Chang, Joe Y.

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non–small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39–86). The median follow-up duration was 21 months (range, 4–58) in all patients and 26 months (range, 4–58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive

  9. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shirvani, Shervin M.; Komaki, Ritsuko [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Heymach, John V.; Fossella, Frank V. [Department of Thoracic/Head and Neck Medical Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Chang, Joe Y., E-mail: jychang@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non-small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39-86). The median follow-up duration was 21 months (range, 4-58) in all patients and 26 months (range, 4-58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive intensity

  10. MRI-guided biopsies and minimally invasive therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Sangeet Ghai

    2015-01-01

    Full Text Available Recent advances in multiparametric magnetic resonance imaging (mp-MRI have led to a paradigm shift in the diagnosis and management of prostate cancer (PCa. Its sensitivity in detecting clinically significant cancer and the ability to localize the tumor within the prostate gland has opened up discussion on targeted diagnosis and therapy in PCa. Use of mp-MRI in conjunction with prostate-specific antigen followed by targeted biopsy allows for a better diagnostic pathway than transrectal ultrasound (TRUS biopsy and improves the diagnosis of PCa. Improved detection of PCa by mp-MRI has also opened up opportunities for focal therapy within the organ while reducing the incidence of side-effects associated with the radical treatment methods for PCa. This review discusses the evidence and techniques for in-bore MRI-guided prostate biopsy and provides an update on the status of MRI-guided targeted focal therapy in PCa.

  11. Ultrasonography, angiography, computed tomography and magnetic resonance in nodular regenerative hyperplasia of the liver

    International Nuclear Information System (INIS)

    Patriarche, C.; Pelletier, G.; Attali, P.; Ladouch-Badre, A.; Fabre, M.; Roche, A.; Etienne, J.P.

    1988-01-01

    Ultrasonographic, computed tomographic, and angiographic abnormalities of nodular regenerative hyperplasia have been described in very few cases. We report here the case of a 50-year-old man with round, well-limited hypoechogenic lesions involving the two lobes of the liver, and hypervascular, poorly delineated angiographic lesions. Computed tomography and magnetic resonance of the liver were normal. Histological examination of large liver specimens provided by intraoperative biopsy allowed the diagnosis of nodular regenerative hyperplasia. Such a pseudo-tumoral ultrasonographic and angiographic pattern must be recognized in order to avoid diagnostic and therapeutic mistakes, especially since percutaneous liver biopsy usually fails to diagnose this disease. (author)

  12. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  13. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    International Nuclear Information System (INIS)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes

    2015-01-01

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  14. Hepatic hemangiomas as diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Sachse, M.

    1987-01-01

    A total of 62 cases where the clinical diagnosis of hepatic hemangioma had been established during the period between 1981 and 1983 on the basis of computed tomography and sonography were subjected to retrospective analysis with the aim of evaluating the diagnostic reliability of these two methods. In 29 patients a typical distribution pattern of the contrast medium gave irrefutable evidence of the disease. Hemangiomas were predicted from the results of computed tomography for a further 5 patients with less revealing distribution patterns, although in 4 among these the preliminary diagnosis of hemangioma was disproved by additional diagnostic procedures (scintigraphy, laparoscopy, surgery and biopsy). Out of 16 patients, in which the hemangiomas were diagnosed from the typical patterns created by the contrast medium on the CT scans, 11 showed sonographic findings to confirm the presence of such tumours. This retrospective analysis showed that a correct and positive diagnosis could be established in no more than 7 patients on the basis of sonography alone, while 6 such diagnoses were definitely proven to be false-positive. As regards diagnostic accuracy, sonography clearly compares unfavourably with computed tomography. It may offer some advantages inasmuch as it requires no radiation exposure, is non-invasive and, last not least, less costly. (ECB) [de

  15. Iterative reconstruction for x-ray computed tomography using prior-image induced nonlocal regularization.

    Science.gov (United States)

    Zhang, Hua; Huang, Jing; Ma, Jianhua; Bian, Zhaoying; Feng, Qianjin; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2014-09-01

    Repeated X-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the X-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as "PWLS-PINL". Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive overrelaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection, and edge detail preservation.

  16. A case of lung abscess successfully treated by transbronchial drainage using a guide sheath.

    Science.gov (United States)

    Izumi, Hiroki; Kodani, Masahiro; Matsumoto, Shingo; Kawasaki, Yuji; Igishi, Tadashi; Shimizu, Eiji

    2017-05-01

    A 51-year-old man was diagnosed with colon cancer in September 2011, and a solitary pulmonary nodule was detected by computed tomography (CT) scan. We performed a transbronchial biopsy with endobronchial ultrasonography using a guide sheath (GS) and diagnosed lung metastasis of colon cancer. The patient experienced remittent fever after the biopsy in spite of intravenous antibiotic therapies. Moreover, his CT scan showed a large lung abscess at the biopsy site. We performed transbronchial drainage using a GS as salvage therapy. The bloody pus was successfully aspirated, and chest X-ray following the procedure showed dramatic shrinkage of the abscess.

  17. Head and neck: normal variations and benign findings in FDG positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-04-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. CT-guided stereotaxic biopsy in 104 cases of brain tumors

    International Nuclear Information System (INIS)

    Niizuma, Hiroshi; Nakasato, Nobukazu; Jokura, Hidehumi; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    Biopsy of suspected brain tumor was performed on 104 cases using Leksell's CT-guided stereotaxic system. The entire operation was performed in the CT room. A Backlund's spiral biopsy needle was advanced to the target point in a stepwise fashion and two to nine tissue samples were obtained from one to three biopsy tracks. Tissue sampling was impossible in two cases because the tumors were too hard for biopsy needle to advance. Also, sampling was sometimes difficult in the case of soft and necrotic tumor, cystic tumor, already treated (irradiated) tumor and the lesion including old blood clot. After the biopsy, minimal bleeding occurred in nine cases, however, stopped within 10 minutes by controlling the blood pressure. A minimum sized hematoma was visible on the postoperative CT in four cases. Postoperative neurological deterioration was seen in two cases. One case was transient and the other seemed to be in his natural course. Anyway, there were neither cases of operative mortality nor severely complicated cases in these series. Useful pathological diagnosis was possible in 83 cases (80 %). Accurate diagnosis was not possible in the remaining 21 cases, however, their histological datum such as necrosis, blood clot, and so on were very useful to estimate the lesions. In summary, accurate diagnosis rate of CT-guided stereotaxic needle biopsy was 80 %. However, it appeared to be a safe and useful procedure in the diagnosis of intracranial mass lesions. (author)

  19. Computed tomography and the TNM classification of lung cancer

    International Nuclear Information System (INIS)

    Sparup, J.; Friis, M.; Brenoee, J.; Vejlsted, H.; Villumsen, B.; Olesen, K.P.; Borgeskov, S.; Bertelsen, S.

    1990-01-01

    Computed tomography (CT)of the thorax and upper abdomen was prospectively evaluated in 84 patients with potentially operable lung cancer. Invasion into the thoracic wall and the mediastinal structures was not accurately demonstrated by CT. For metastatic mediastinal lymph nodes, the sensitivity and specificity of CT were, respectively, 86 per cent and 61 per cent and the positive and negative predictive indices 49 per cent and 91 per cent. For T1, T2 and T3 tumours the negative indices were 100 per cent, 96 per cent and 71 per cent. Positive predictive index did not differ between squamous cell carcinoma and adenocarcinoma. Adrenal metastases were CT-suspected in 17 cases and liver metastases in eight, but were verified by ultrasonography in only one and four cases. CT should be used in preoperative investigation of lung cancer, irrespective of stage. Demonstration of thoracic-wall or mediastinal invasion need not exclude tumour resection. Preoperative mediastinoscopy is indicated if CT shows nodal metastases or if there are signs of tumour invasion, but not in CT-negative T1 or T2 tumour. Abdominal metastases indicated by CT should be investigated with CT-guided needle biopsy. (authors)

  20. Prosthesis-guided implant restoration of an auricular defect using computed tomography and 3-dimensional photographic imaging technologies: a clinical report.

    Science.gov (United States)

    Wang, Shuming; Leng, Xu; Zheng, Yaqi; Zhang, Dapeng; Wu, Guofeng

    2015-02-01

    The concept of prosthesis-guided implantation has been widely accepted for intraoral implant placement, although clinicians do not fully appreciate its use for facial defect restoration. In this clinical report, multiple digital technologies were used to restore a facial defect with prosthesis-guided implantation. A simulation surgery was performed to remove the residual auricular tissue and to ensure the correct position of the mirrored contralateral ear model. The combined application of computed tomography and 3-dimensional photography preserved the position of the mirrored model and facilitated the definitive implant-retained auricular prosthesis. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Detection of suspicious malignant cervical lymph nodes of unknown origin: diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy with nodal size and central necrosis correlate

    International Nuclear Information System (INIS)

    Lo, C.-P.; Chen, C.-Y.; Chin, S-.C.; Lee, K.-W.; Hsueh, C.-J.; Juan, C.-J.; Kao, H.-W.; Huang, G.-S.

    2007-01-01

    To assess the role of ultrasound-guided fine-needle aspiration biopsy (US-guided FNAB) in the diagnostic workup of suspicious malignant cervical lymph nodes in patients with palpable neck masses and without known primary cancer. The diagnostic accuracy of imaging morphologic criteria, including sizes and central necrosis for assessing suspicious malignant nodes, were also examined. This is a retrospective study of 426 patients with palpable neck masses from an outpatient department evaluated with computed tomography, magnetic resonance imaging, or US. US-guided FNABs were performed in 102 patients with suspicious malignant cervical lymph nodes at a single institution. Cytologically positive lymph nodes (n = 12) were further validated with excisional biopsy. Negative lymph nodes (n = 90) were either excised (n = 10) or followed up by imaging studies for at least one year (n = 80). The diagnostic accuracy of the FNABs along with the imaging findings of nodal sizes and presence of central necrosis, which were classified by a consensus of 2 radiologists, were assessed. Twelve malignant nodes were detected with US-guided FNAB with one false-positive and one false-negative result. The overall sensitivity, specificity, and accuracy for FNAB were 91.7%, 98.9%, and 98.0%. respectively. The sensitivity, specificity, and accuracy were 66.7%, 30.0%, and 34.3% for size criterion and 75.0%, 83.3%, and 82.3% for central necrosis criterion. The size of cervical lymph node does not appear to be an important imaging criterion for assessing suspicious malignant lymph nodes, compared with the criterion of central necrosis. US-guided FNAB is highly specific and sensitive in the diagnostic workup of suspicious malignant cervical lymph nodes in patients without known primary cancers. (author)

  2. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  3. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...... underwent TRUS-bx followed by bp-MRI-guided biopsies (bp-MRI-bx) under MRI/TRUS image fusion from any bp-MRI suspicious lesions not obviously targeted by TRUS-bx. RESULTS: PCa was found in 42 (68%) and 32 (52%) patients by TRUS-bx and bp-MRI-bx, respectively. Bp-MRI-bx de-tected PCa in one patient who had...

  4. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  5. The reliability of cone-beam computed tomography to assess bone density at dental implant recipient sites: a histomorphometric analysis by micro-CT.

    Science.gov (United States)

    González-García, Raúl; Monje, Florencio

    2013-08-01

    The aim of this study was to objectively assess the reliability of the cone-beam computed tomography (CBCT) as a tool to pre-operatively determine radiographic bone density (RBD) by the density values provided by the system, analyzing its relationship with histomorphometric bone density expressed as bone volumetric fraction (BV/TV) assessed by micro-CT of bone biopsies at the site of insertion of dental implants in the maxillary bones. Thirty-nine bone biopsies of the maxillary bones at the sites of 39 dental implants from 31 edentulous healthy patients were analyzed. The NobelGuide™ software was used for implant planning, which also allowed fabrication of individual stereolithographic surgical guides. The analysis of CBCT images allowed pre-operative determination of mean density values of implant recipient sites along the major axis of the planned implants (axial RBD). Stereolithographic surgical guides were used to guide implant insertion and also to extract cylindrical bone biopsies from the core of the exact implant site. Further analysis of several osseous micro-structural variables including BV/TV was performed by micro-CT of the extracted bone biopsies. Mean axial RBD was 478 ± 212 (range: 144-953). A statistically significant difference (P = 0.02) was observed among density values of the cortical bone of the upper maxilla and mandible. A high positive Pearson's correlation coefficient (r = 0.858, P micro-CT at the site of dental implants in the maxillary bones. Pre-operative estimation of density values by CBCT is a reliable tool to objectively determine bone density. © 2012 John Wiley & Sons A/S.

  6. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  7. Extrapeural locating method: significance in CT-guided transthoracic pulmonary biopsy

    International Nuclear Information System (INIS)

    Tang Guangjian; Wang Rengui; Liu Jianxin; Sun Jingtao

    2008-01-01

    Objective: To evaluate the usefulness of extrapleural locating method in CT-guided transthoracic pulmonary biopsy to prevent or reduce the size of peumothorax. Methods: One hundred and fifteen cases of CT-guided transthoracic pulmonary biopsy with the pulmonary lesions not in direct contact with the pleura were selected. Of 115 cases, 46 were performed with extrapleural locating method (EPL) and 69 cases with lesion edge locating method (LEL). Taking the maximum distance between the partial and visceral pleura (MPVD) measured on the CT image after the procedure as the index of the volume of pneumothorax. The incidence and volume of pneumothorax of both groups were compared and statistically analysed with R x C Chi-Square test. The retention time of the biopsy needle in the lung parenchyma of the two group was documented and the average time was calculated in each group. Results: The incidence of pneumothorax was 45.7% (21/46), median 0.4 cm with EPL group, and 66.7% (46/69) and median 0.3cm with LEL group. When the distance between the lesion and pleura was equal or smaller than 2 cm (≤2cm), the incidence of pneumothorax was 39.4% (13/33) with EPL group and 73.2% (30/41) with LEL group, and the difference of incidence and volume of the pneumothorax between two groups was statistically significant(χ 2 =9.981, P=0.019). When the distance was larger than 2 cm (>2 cm), the incidence and volume of pneumothorax between two groups were not significant statistically. The average retention time of the biopsy needle in the lung parenchyma was (7.2 ± 1.8) s with EPL group and (58.3 ± 11.6) s with LEL group. Conclusion: The extrapleural locating method can reduce effectively the retention time of the biopsy needle in the lung parenchyma and the incidence and volume of pneumothorax in CT-guided transthoracic pulmonary biopsy. (authors)

  8. 3D artificial bones for bone repair prepared by computed tomography-guided fused deposition modeling for bone repair.

    Science.gov (United States)

    Xu, Ning; Ye, Xiaojian; Wei, Daixu; Zhong, Jian; Chen, Yuyun; Xu, Guohua; He, Dannong

    2014-09-10

    The medical community has expressed significant interest in the development of new types of artificial bones that mimic natural bones. In this study, computed tomography (CT)-guided fused deposition modeling (FDM) was employed to fabricate polycaprolactone (PCL)/hydroxyapatite (HA) and PCL 3D artificial bones to mimic natural goat femurs. The in vitro mechanical properties, in vitro cell biocompatibility, and in vivo performance of the artificial bones in a long load-bearing goat femur bone segmental defect model were studied. All of the results indicate that CT-guided FDM is a simple, convenient, relatively low-cost method that is suitable for fabricating natural bonelike artificial bones. Moreover, PCL/HA 3D artificial bones prepared by CT-guided FDM have more close mechanics to natural bone, good in vitro cell biocompatibility, biodegradation ability, and appropriate in vivo new bone formation ability. Therefore, PCL/HA 3D artificial bones could be potentially be of use in the treatment of patients with clinical bone defects.

  9. Cross-sectional anatomy for computed tomography

    International Nuclear Information System (INIS)

    Farkas, M.L.

    1988-01-01

    This self-study guide recognizes that evaluation and interpretation of CT-images demands a firm understanding of both cross-sectional anatomy and the principles of computed tomography. The objectives of this book are: to discuss the basic principles of CT, to stress the importance of cross-sectional anatomy to CT through study of selected cardinal transverse sections of head, neck, and trunk, to explain orientation and interpretation of CT-images with the aid of corresponding cross-sectional preparations

  10. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  11. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  12. CT-guided percutaneous spine biopsy in suspected infection or malignancy. A study of 214 patients

    Energy Technology Data Exchange (ETDEWEB)

    Rehm, J.; Veith, S.; Kauczor, H.U.; Weber, M.A. [Heidelberg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology; Akbar, M. [Heidelberg Univ. (Germany). Dept. of Orthopaedic Surgery and Rehabilitation Medicine

    2016-12-15

    To retrospectively determine the effectiveness and accuracy of CT-guided percutaneous biopsy of malignant and inflammatory bone lesions of the spine and to assess the reliability of pre-biopsy CT and MRI. 214 patients with lesions of the spine, which were suspicious either for being malignant or inflammatory, underwent CT-guided biopsy for pathological and/or microbiological detection. Biopsy samples were sent for histological examination in 128/214 patients, for microbiological analysis in 17/214 patients and for both analyses in 69/214 patients. Retrospectively, the diagnostic accuracy and sensitivity/specificity of the pre-interventional imaging (CT and MRI) were determined. In addition, the influence of the biopsy on subsequent patient management was assessed. The accuracy was 94.4% for histopathological analysis and 97.7% for microbiological analysis. In 25% of cases the microbiological analysis revealed an underlying pathogen that was not significantly affected by pre-biopsy antibiotic therapy. The sensitivity/specificity of the pre-biopsy cross-sectional imaging concerning suspected malignancy was 69%/78%. For suspected infection, the sensitivity/specificity of pre-biopsy imaging was 81%/44%. In 52% of all cases, the biopsy result changed subsequent patient management. Percutaneous CT-guided spine biopsy is a useful and reliable diagnostic procedure to establish a definitive diagnosis but with a relatively low yield of microorganisms in the case of infection.

  13. CT-guided percutaneous spine biopsy in suspected infection or malignancy. A study of 214 patients

    International Nuclear Information System (INIS)

    Rehm, J.; Veith, S.; Kauczor, H.U.; Weber, M.A.; Akbar, M.

    2016-01-01

    To retrospectively determine the effectiveness and accuracy of CT-guided percutaneous biopsy of malignant and inflammatory bone lesions of the spine and to assess the reliability of pre-biopsy CT and MRI. 214 patients with lesions of the spine, which were suspicious either for being malignant or inflammatory, underwent CT-guided biopsy for pathological and/or microbiological detection. Biopsy samples were sent for histological examination in 128/214 patients, for microbiological analysis in 17/214 patients and for both analyses in 69/214 patients. Retrospectively, the diagnostic accuracy and sensitivity/specificity of the pre-interventional imaging (CT and MRI) were determined. In addition, the influence of the biopsy on subsequent patient management was assessed. The accuracy was 94.4% for histopathological analysis and 97.7% for microbiological analysis. In 25% of cases the microbiological analysis revealed an underlying pathogen that was not significantly affected by pre-biopsy antibiotic therapy. The sensitivity/specificity of the pre-biopsy cross-sectional imaging concerning suspected malignancy was 69%/78%. For suspected infection, the sensitivity/specificity of pre-biopsy imaging was 81%/44%. In 52% of all cases, the biopsy result changed subsequent patient management. Percutaneous CT-guided spine biopsy is a useful and reliable diagnostic procedure to establish a definitive diagnosis but with a relatively low yield of microorganisms in the case of infection.

  14. Computed tomography diagnosis of active bleeding into the thyroid gland.

    Science.gov (United States)

    Veverková, Lucia; Bakaj-Zbrožková, Lenka; Hallamová, Lucie; Heřman, Miroslav

    2013-10-01

    Fine-needle biopsy of the thyroid gland is the most common interventional procedure used to diagnose thyroid diseases. Serious complications are rare in this procedure. They comprise an infection with abscess formation and hemorrhage. To date, only a few case reports have described an ultrasound diagnosis of active bleeding into the thyroid gland. We established such a diagnosis using computed tomography (CT). A 74-year-old woman presented to the emergency department of our hospital with complications after fine-needle biopsy of the thyroid gland. Ultrasound revealed a large hematoma surrounding the gland. A subsequent CT scan confirmed the presence of hematoma and, moreover, showed active bleeding. This finding prompted rapid surgical intervention. CT has the capability to show active bleeding into the thyroid gland.

  15. Application of positron emission tomography-computed tomography in the diagnosis of pulmonary ground-glass nodules.

    Science.gov (United States)

    Hu, Lili; Pan, Yuanwei; Zhou, Zhigang; Gao, Jianbo

    2017-11-01

    The aim of the present study was to investigate the value of positron emission tomography-computed tomography (PET-CT) using 18 F-fluorodeoxyglucose in the clinical diagnosis of pulmonary ground-glass nodule. In total, 54 patients with pulmonary GGN that were identified by PET-CT examination were selected and confirmed by pathology and clinical diagnosis in hospital between April 2014 and April 2015. The association between PET-CT findings and pathology, and the value of PET-CT were then evaluated. In the 54 patients, solitary pulmonary GGN with a nodule diameter of between 0.6 and 2.0 cm were detected. Amongst them, the PET-CT examination of 42 patients revealed hyper metabolic nodules, and were all mixed GGN type nodules with a diameter >1 cm. The PET-CT examination of the remaining 12 patients demonstrated no evidence of metabolic abnormalities and the nodules in these patients were pure or mixed GGN with a diameter <1 cm (except 2 cases with a diameter ≥1 cm). Furthermore, the diagnoses for all patients were pathologically confirmed by CT-guided needle biopsy or thoracoscopic surgical resection. Amongst them, there were 41 cases of lung adenocarcinoma, 4 cases of fungal infection, 7 cases of inflammation and 2 cases of adenomatoid hyperplasia. Additionally, PET-CT has a lower detection rate for smaller GGN exhibits no clear advantage for pure GGN, but has a higher detection rate for larger GGN. In conclusion, to a certain extent, PET-CT makes up for the shortcomings of traditional imaging and has some clinical value for the diagnosis of GGN.

  16. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Fabel, Michael; Bolte, Hendrik; Schaefer, Fritz K. W.; Jahnke, Thomas; Heller, Martin; Lammer, Johannes; Biederer, Juergen

    2010-01-01

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 ± 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 ± 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 ± 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 ± 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 ± 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

  17. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  20. The clinical utility of multimodal MR image-guided needle biopsy in cerebral gliomas.

    Science.gov (United States)

    Yao, Chengjun; Lv, Shunzeng; Chen, Hong; Tang, Weijun; Guo, Jun; Zhuang, Dongxiao; Chrisochoides, Nikos; Wu, Jinsong; Mao, Ying; Zhou, Liangfu

    2016-01-01

    Our aim was to evaluate the diagnostic value of multimodal Magnetic Resonance (MR) Image in the stereotactic biopsy of cerebral gliomas, and investigate its implications. Twenty-four patients with cerebral gliomas underwent (1)H Magnetic Resonance Spectroscopy ((1)H-MRS)- and intraoperative Magnetic Resonance Imaging (iMRI)-supported stereotactic biopsy, and 23 patients underwent only the preoperative MRI-guided biopsy. The diagnostic yield, morbidity and mortality rates were analyzed. In addition, 20 patients underwent subsequent tumor resection, thus the diagnostic accuracy of the biopsy was further evaluated. The diagnostic accuracies of biopsies evaluated by tumor resection in the trial groups were better than control groups (92.3% and 42.9%, respectively, p = 0.031). The diagnostic yield in the trial groups was better than the control groups, but the difference was not statistically significant (100% and 82.6%, respectively, p = 0.05). The morbidity and mortality rates were similar in both groups. Multimodal MR image-guided glioma biopsy is practical and valuable. This technique can increase the diagnostic accuracy in the stereotactic biopsy of cerebral gliomas. Besides, it is likely to increase the diagnostic yield but requires further validation.

  1. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  4. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT

    International Nuclear Information System (INIS)

    Chami, H.A.; Faraj, W.; Yehia, Z.A.; Badour, S.A.; Sawan, P.; Rebeiz, K.; Safa, R.; Saade, C.; Ghandour, B.; Shamseddine, A.; Mukherji, D.; Haydar, A.A.

    2015-01-01

    Aim: To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. Materials and methods: One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below −950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Results: Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01–1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Conclusion: Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. - Highlights: • Examine the association between quantitative emphysema measures & post NLB pneumothorax. • The risk of post-NLB pneumothorax increases with every unit increase in percent emphysema. • Percent emphysema is a significant predictor of pneumothorax post transthoracic NLB. • Quantitative analysis of chest CT offers clinicians' objective measures to assess pneumothorax risk.

  5. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    Science.gov (United States)

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  6. Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.

    Science.gov (United States)

    Tudor, G R; Rodgers, P M; West, K P

    1999-08-01

    Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.

  7. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  8. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  9. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  10. In-bore setup and software for 3T MRI-guided transperineal prostate biopsy

    International Nuclear Information System (INIS)

    Tokuda, Junichi; Tuncali, Kemal; Song, Sang-Eun; Fedorov, Andriy; Oguro, Sota; Fennessy, Fiona M; Tempany, Clare M; Hata, Nobuhiko; Iordachita, Iulian; Lasso, Andras

    2012-01-01

    MRI-guided prostate biopsy in conventional closed-bore scanners requires transferring the patient outside the bore during needle insertion due to the constrained in-bore space, causing a safety hazard and limiting image feedback. To address this issue, we present our custom-made in-bore setup and software to support MRI-guided transperineal prostate biopsy in a wide-bore 3 T MRI scanner. The setup consists of a specially designed tabletop and a needle-guiding template with a Z-frame that gives a physician access to the perineum of the patient at the imaging position and allows the physician to perform MRI-guided transperineal biopsy without moving the patient out of the scanner. The software and Z-frame allow registration of the template, target planning and biopsy guidance. Initially, we performed phantom experiments to assess the accuracy of template registration and needle placement in a controlled environment. Subsequently, we embarked on our clinical trial (N = 10). The phantom experiments showed that the translational errors of the template registration along the right–left (RP) and anterior–posterior (AP) axes were 1.1 ± 0.8 and 1.4 ± 1.1 mm, respectively, while the rotational errors around the RL, AP and superior–inferior axes were (0.8 ± 1.0)°, (1.7 ± 1.6)° and (0.0 ± 0.0)°, respectively. The 2D root-mean-square (RMS) needle-placement error was 3 mm. The clinical biopsy procedures were safely carried out in all ten clinical cases with a needle-placement error of 5.4 mm (2D RMS). In conclusion, transperineal prostate biopsy in a wide-bore 3T scanner is feasible using our custom-made tabletop setup and software, which supports manual needle placement without moving the patient out of the magnet. (paper)

  11. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy

    Science.gov (United States)

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  12. Just-in-time tomography (JiTT): a new concept for image-guided radiation therapy

    International Nuclear Information System (INIS)

    Pang, G; Rowlands, J A

    2005-01-01

    Soft-tissue target motion is one of the main concerns in high-precision radiation therapy. Cone beam computed tomography (CBCT) has been developed recently to image soft-tissue targets in the treatment room and guide the radiation therapy treatment. However, due to its relatively long image acquisition time the CBCT approach cannot provide images of the target at the instant of the treatment and thus it is not adequate for imaging targets with intrafraction motion. In this note, a new approach for image-guided radiation therapy-just-in-time tomography (JiTT)-is proposed. Differing from CBCT, JiTT takes much less time to generate the needed tomographical, beam's-eye-view images of the treatment target at the right moment to guide the radiation therapy treatment. (note)

  13. Ultrasound-guided Breast Biopsy in the Resource-limited Setting: An Initial Experience in Rural Uganda

    Directory of Open Access Journals (Sweden)

    Christopher R. Stark

    2017-06-01

    Full Text Available Purpose: To describe the methodology and initial experience behind creation of an ultrasoundguided percutaneous breast core biopsy program in rural Uganda. Methods and Materials: Imaging the World Africa (ITWA is the registered non-governmental organization division of Imaging the World (ITW, a not-for-profit organization whose primary aim is the integration of affordable high-quality ultrasound into rural health centers. In 2013, ITWA began the pilot phase of an IRB-approved breast care protocol at a rural health center in Uganda. As part of the protocol’s diagnostic arm, an ultrasound-guided percutaneous breast core biopsy training curriculum was implemented in tandem with creation of regionally supplied biopsy kits. Results: A surgeon at a rural regional referral hospital was successfully trained and certified to perform ultrasound-guided percutaneous breast core biopsies. Affordable and safe biopsy kits were created using locally available medical supplies with the cost of each kit totaling $10.62 USD. Conclusion: Successful implementation of an ultrasound-guided percutaneous breast core biopsy program in the resource-limited setting is possible and can be made sustainable through incorporation of local health care personnel and regionally supplied biopsy materials. Our hope is that ITWA’s initial experience in rural Uganda can serve as a model for similar programs in the future.

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  15. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    Science.gov (United States)

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  16. Preliminary Results of Emergency Computed Tomography-Guided Ventricular Drain Placement-Precision for the Most Difficult Cases.

    Science.gov (United States)

    Nowacki, Andreas; Wagner, Franca; Söll, Nicole; Hakim, Arsany; Beck, Jürgen; Raabe, Andreas; Z'Graggen, Werner J

    2018-04-05

    External ventricular drainage (EVD) catheter placement is one of the most commonly performed neurosurgical procedures. The study's objective was to compare a computed tomography (CT) bolt scan-guided approach for the placement of EVDs with conventional landmark-based insertion. In this retrospective case-control study, we analyzed patients undergoing bolt-kit EVD catheter placement, either CT-guided or landmark-based, between 2013 and 2016. The CT bolt scan-guided approach was based on a dose-reduced CT scan after bolt fixation with immediate image reconstruction along the axis of the bolt to evaluate the putative insertion axis. If needed, angulation of the bolt was corrected and the procedure repeated before the catheter was inserted. Primary endpoint was the accuracy of insertion. Secondary endpoints were the overall number of attempts, duration of intervention, complication rates, and cumulative radiation dose. In total, 34 patients were included in the final analysis. In the group undergoing CT-guided placement, the average ventricle width was significantly smaller (P = 0.04) and average midline shift significantly more pronounced (P = 0.01). CT-guided placement resulted in correct positioning of the catheter in the ipsilateral frontal horn in all 100% of the cases compared with landmark-guided insertion (63%; P = 0.01). Application of the CT-guided approach increased the number of total CT scans (3.6 ± 1.9) and the overall radiation dose (3.34 ± 1.61 mSv) compared with the freehand insertion group (1.84 ± 2.0 mSv and 1.55 ± 1.66 mSv). No differences were found for the other secondary outcome parameters. CT-guided bolt-kit EVD catheter placement is feasible and accurate in the most difficult cases. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Imaging-histologic discordance at sonographically guided percutaneous biopsy of breast lesions

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Park, Sun Young; Jung, Hae Kyoung; Park, Byeong-Woo; Kim, Haeryung; Oh, Ki Keun

    2008-01-01

    Objective: To determine the frequency of imaging-histologic discordance at percutaneous breast biopsy and to evaluate differences in clinical and radiologic findings between pathologically upgraded lesions and non-upgraded lesions. Materials and methods: From February 2000 to June 2005, we reviewed 386 cases that had suspicious imaging findings but yielded benign histology at US-core needle biopsy and that underwent subsequent excisional biopsy. In 74 of 386 cases, the benign histology at core needle biopsy could not provide a satisfactory explanation for the radiologically suspicious lesions. The clinical, radiologic and histologic findings were reviewed for those 74 cases that were classified as the upgrade group and the non-upgrade group after excisional biopsy. Results: The upgrade rate was 17.6% (95% confidence interval, 10.6-27.8%, 13 of 74 cases) revealed upgraded pathology at the subsequent excisional biopsy. Besides the size of masses, there were no statistically significant differences in imaging findings between the upgrade and non-upgrade groups at excisional biopsy. Conclusion: This upgrade rate of 17.6% suggests that excisional biopsy or re-biopsy is warranted in those cases presenting imaging-histologic discordance at US-guided core biopsy

  18. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  19. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  20. Computed tomography guided navigation assisted percutaneous ablation of osteoid osteoma in a 7-year-old patient: the low dose approach

    Energy Technology Data Exchange (ETDEWEB)

    Krokidis, Miltiadis; Tappero, Carlo; Bogdanovic, Daniel; Stamm, Anna-Christina [Inselspital, Bern University Hospital, Department of Diagnostic, Interventional and Pediatric Radiology, Bern (Switzerland); Ziebarth, Kai [Inselspital, Bern University Hospital, Department of Pediatric Surgery, Bern (Switzerland)

    2017-07-15

    Osteoid osteoma (OO) is a benign tumour that can cause severe pain and functional limitation to children and young adults; the treatment of choice is image-guided ablation. Due to the very small size of the lesion, detection and accurate needle placement may be challenging. Computed tomography (CT) offers very detailed imaging of the skeleton and is the modality of choice for the detection of small OO and for ablation guidance. Nevertheless, CT-guided positioning of the ablation applicator is linked to significant radiation exposure, particularly for the paediatric population. This case describes the successful use of a novel CT-based navigation system that offers the possibility of accurate ablation with only minimal radiation exposure in a paediatric patient. (orig.)

  1. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI.

    Science.gov (United States)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-12-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. • Post-clip MRI is useful for confirming adequate sampling of US-guided biopsy. • Post-clip MRI following US-guided biopsy revealed a 96.6 % technical success rate. • One technical failure case was a benign, 1.1-cm non-mass enhancement. • The technical success rate of US-guided biopsy for non-mass enhancements was 83.3 %.

  2. Comparison of the accuracy of cone beam computed tomography and medical computed tomography: implications for clinical diagnostics with guided surgery.

    Science.gov (United States)

    Abboud, Marcus; Calvo-Guirado, Jose Luis; Orentlicher, Gary; Wahl, Gerhard

    2013-01-01

    This study compared the accuracy of cone beam computed tomography (CBCT) and medical-grade CT in the context of evaluating the diagnostic value and accuracy of fiducial marker localization for reference marker-based guided surgery systems. Cadaver mandibles with attached radiopaque gutta-percha markers, as well as glass balls and composite cylinders of known dimensions, were measured manually with a highly accurate digital caliper. The objects were then scanned using a medical-grade CT scanner (Philips Brilliance 64) and five different CBCT scanners (Sirona Galileos, Morita 3D Accuitomo 80, Vatech PaX-Reve3D, 3M Imtech Iluma, and Planmeca ProMax 3D). The data were then imported into commercially available software, and measurements were made of the scanned markers and objects. CT and CBCT measurements were compared to each other and to the caliper measurements. The difference between the CBCT measurements and the caliper measurements was larger than the difference between the CT measurements and the caliper measurements. Measurements of the cadaver mandible and the geometric reference markers were highly accurate with CT. The average absolute errors of the human mandible measurements were 0.03 mm for CT and 0.23 mm for CBCT. The measurement errors of the geometric objects based on CT ranged between 0.00 and 0.12 mm, compared to an error range between 0.00 and 2.17 mm with the CBCT scanners. CT provided the most accurate images in this study, closely followed by one CBCT of the five tested. Although there were differences in the distance measurements of the hard tissue of the human mandible between CT and CBCT, these differences may not be of clinical significance for most diagnostic purposes. The fiducial marker localization error caused by some CBCT scanners may be a problem for guided surgery systems.

  3. Image-Guided Radiotherapy for Liver Cancer Using Respiratory-Correlated Computed Tomography and Cone-Beam Computed Tomography

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Sweeney, Reinhart A.; Wilbert, Juergen; Krieger, Thomas; Richter, Anne; Baier, Kurt; Mueller, Gerd; Sauer, Otto; Flentje, Michael

    2008-01-01

    Purpose: To evaluate a novel four-dimensional (4D) image-guided radiotherapy (IGRT) technique in stereotactic body RT for liver tumors. Methods and Materials: For 11 patients with 13 intrahepatic tumors, a respiratory-correlated 4D computed tomography (CT) scan was acquired at treatment planning. The target was defined using CT series reconstructed at end-inhalation and end-exhalation. The liver was delineated on these two CT series and served as a reference for image guidance. A cone-beam CT scan was acquired after patient positioning; the blurred diaphragm dome was interpreted as a probability density function showing the motion range of the liver. Manual contour matching of the liver structures from the planning 4D CT scan with the cone-beam CT scan was performed. Inter- and intrafractional uncertainties of target position and motion range were evaluated, and interobserver variability of the 4D-IGRT technique was tested. Results: The workflow of 4D-IGRT was successfully practiced in all patients. The absolute error in the liver position and error in relation to the bony anatomy was 8 ± 4 mm and 5 ± 2 mm (three-dimensional vector), respectively. Margins of 4-6 mm were calculated for compensation of the intrafractional drifts of the liver. The motion range of the diaphragm dome was reproducible within 5 mm for 11 of 13 lesions, and the interobserver variability of the 4D-IGRT technique was small (standard deviation, 1.5 mm). In 4 patients, the position of the intrahepatic lesion was directly verified using a mobile in-room CT scanner after application of intravenous contrast. Conclusion: The results of our study have shown that 4D image guidance using liver contour matching between respiratory-correlated CT and cone-beam CT scans increased the accuracy compared with stereotactic positioning and compared with IGRT without consideration of breathing motion

  4. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    Science.gov (United States)

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  5. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  6. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  7. Computed tomography-guided percutaneous trephine removal of the nidus in osteoid osteoma patients: experience of a single center in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Petrilli, Marcelo; Senerchia, Andreza Almeida; Petrilli, Antonio Sergio; Lederman, Henrique Manoel; Garcia Filho, Reynaldo Jesus, E-mail: andrezasenerchia@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Instituto de Oncologia Pediatrica

    2015-07-15

    Objective: to report the results of computed tomography (CT)-guided percutaneous resection of the nidus in 18 cases of osteoid osteoma. Materials and methods: the medical records of 18 cases of osteoid osteoma in children, adolescents and young adults, who underwent CT-guided removal of the nidus between November, 2004 and March, 2009 were reviewed retrospectively for demographic data, lesion site, clinical outcome and complications after procedure. Results: clinical follow-up was available for all cases at a median of 29 months (range 6-60 months). No persistence of pre-procedural pain was noted on 17 patients. Only one patient experienced recurrence of symptoms 12 months after percutaneous resection, and was successfully retreated by the same technique, resulting in a secondary success rate of 18/18 (100%). Conclusion: CT-guided removal or destruction of the nidus is a safe and effective alternative to surgical resection of the osteoid osteoma nidus. (author)

  8. Effects of a Multidisciplinary Approach to Improve Volume of Diagnostic Material in CT-Guided Lung Biopsies.

    Science.gov (United States)

    Ferguson, Philip E; Sales, Catherine M; Hodges, Dalton C; Sales, Elizabeth W

    2015-01-01

    Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9-1.1 cm) in 2007 to 2.5 cm (2.3-2.8 cm) in 2012 (Pstrategy to CT-guided lung biopsies was effective in significantly increasing tissue volume and number of blocks available for advanced diagnostic testing.

  9. Clinical Utility of Preoperative Computed Tomography in Patients With Endometrial Cancer.

    Science.gov (United States)

    Bogani, Giorgio; Gostout, Bobbie S; Dowdy, Sean C; Multinu, Francesco; Casarin, Jvan; Cliby, William A; Frigerio, Luigi; Kim, Bohyun; Weaver, Amy L; Glaser, Gretchen E; Mariani, Andrea

    2017-10-01

    The aim of this study was to determine the clinical utility of routine preoperative pelvic and abdominal computed tomography (CT) examinations in patients with endometrial cancer (EC). We retrospectively reviewed records from patients with EC who underwent a preoperative endometrial biopsy and had surgery at our institution from January 1999 through December 2008. In the subset with an abdominal CT scan obtained within 3 months before surgery, we evaluated the clinical utility of the CT scan. Overall, 224 patients (18%) had a preoperative endometrial biopsy and an available CT scan. Gross intra-abdominal disease was observed in 10% and 20% of patients with preoperative diagnosis of endometrioid G3 and type II EC, respectively, whereas less than 5% of patients had a preoperative diagnosis of hyperplasia or low-grade EC. When examining retroperitoneal findings, we observed that a negative CT scan of the pelvis did not exclude the presence of pelvic node metastasis. Alternately, a negative CT scan in the para-aortic area generally reduced the probability of finding para-aortic dissemination but with an overall low sensitivity (42%). However, the sensitivity for para-aortic dissemination was as high as 67% in patients with G3 endometrioid cancer. In the case of negative para-aortic nodes in the CT scan, the risk of para-aortic node metastases decreased from 18.8% to 7.5% in patients with endometrioid G3 EC. Up to 15% of patients with endometrioid G3 cancer had clinically relevant incidental findings that necessitated medical or surgical intervention. In patients with endometrioid G3 and type II EC diagnosed by the preoperative biopsy, CT scans may help guide the operative plan by facilitating preoperative identification of gross intra-abdominal disease and enlarged positive para-aortic nodes that are not detectable during physical examinations. In addition, CT may reveal other clinically relevant incidental findings.

  10. Endogenous endophthalmitis caused by Cryptococcus neoformans Var. Gattii mimicking choroidal tumor: From positron-emission tomography/computed tomography to histopathology

    Directory of Open Access Journals (Sweden)

    Chun-Ju Lin

    2017-01-01

    Full Text Available A 60-year-old immunocompetent female with pneumonia history about 10 years ago suffered from blurred vision overall survival for 3 weeks. Common cold with headache and unintentional body weight loss was also noted recently. Choroidal detachment simulating choroidal tumor was observed in the temporal quadrant. The 18F-fluoro-2-deoxyglucose (FDG positron-emission tomography/computed tomography (CT scan showed focal, mild to moderate FDG uptake in the left lateral orbit, and an enhanced lesion was seen on the recent CT scan. The suspicious choroidal tumor became larger in a week. Phacoemulsification, vitrectomy, and retinal biopsies were performed. Histochemical study of the retinal specimens established the diagnosis of endogenous cryptococcal endophthalmitis. Vitreous culture yielded Cryptococcus neoformans var. gattii. Systemic and topical voriconazole eliminated the infection. In the literature, endogenous endophthalmitis caused by C. neoformans var. gattii has not been reported in detail. The key to successful management lies in early diagnosis. If clinical improvement could not be achieved after conventional management and imaging studies have failed to yield a definite diagnosis, retinal biopsy can be considered.

  11. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  12. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    Science.gov (United States)

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  13. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  14. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  15. Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.

    Science.gov (United States)

    Gillies, Derek J; Gardi, Lori; De Silva, Tharindu; Zhao, Shuang-Ren; Fenster, Aaron

    2017-09-01

    During image-guided prostate biopsy, needles are targeted at tissues that are suspicious of cancer to obtain specimen for histological examination. Unfortunately, patient motion causes targeting errors when using an MR-transrectal ultrasound (TRUS) fusion approach to augment the conventional biopsy procedure. This study aims to develop an automatic motion correction algorithm approaching the frame rate of an ultrasound system to be used in fusion-based prostate biopsy systems. Two modes of operation have been investigated for the clinical implementation of the algorithm: motion compensation using a single user initiated correction performed prior to biopsy, and real-time continuous motion compensation performed automatically as a background process. Retrospective 2D and 3D TRUS patient images acquired prior to biopsy gun firing were registered using an intensity-based algorithm utilizing normalized cross-correlation and Powell's method for optimization. 2D and 3D images were downsampled and cropped to estimate the optimal amount of image information that would perform registrations quickly and accurately. The optimal search order during optimization was also analyzed to avoid local optima in the search space. Error in the algorithm was computed using target registration errors (TREs) from manually identified homologous fiducials in a clinical patient dataset. The algorithm was evaluated for real-time performance using the two different modes of clinical implementations by way of user initiated and continuous motion compensation methods on a tissue mimicking prostate phantom. After implementation in a TRUS-guided system with an image downsampling factor of 4, the proposed approach resulted in a mean ± std TRE and computation time of 1.6 ± 0.6 mm and 57 ± 20 ms respectively. The user initiated mode performed registrations with in-plane, out-of-plane, and roll motions computation times of 108 ± 38 ms, 60 ± 23 ms, and 89 ± 27 ms, respectively, and corresponding

  16. {sup 18}F-Choline Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging for the Detection of Early Local Recurrence of Prostate Cancer Initially Treated by Radiation Therapy: Comparison With Systematic 3-Dimensional Transperineal Mapping Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kanoun, Salim, E-mail: Salim.kanoun@gmail.com [Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon (France); LE2I UMR6306, Centre national de la recherche scientifique, Arts et Métiers, Université Bourgogne Franche-Comté, Dijon (France); MRI Unit, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon (France); Walker, Paul [LE2I UMR6306, Centre national de la recherche scientifique, Arts et Métiers, Université Bourgogne Franche-Comté, Dijon (France); MRI Unit, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon (France); Vrigneaud, Jean-Marc; Depardon, Edouard [Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon (France); Barbier, Vincent [Department of Urology, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon (France); Humbert, Olivier [Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon (France); Moulin, Morgan [Department of Urology, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon (France); and others

    2017-04-01

    Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence. Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.

  17. Results and complications of CT-guided biopsy with CT fluoroscopy

    International Nuclear Information System (INIS)

    Saika, Yoshinori; Ogura, Yasuharu; Doi, Kenji; Misaki, Toshimasa; Shimizu, Masashi; Narabayashi, Isamu

    2002-01-01

    We studied the results and complications of CT-guided biopsy with CT fluoroscopy performed 66 lesions in 64 patients from March 1999 to February 2001. In addition to the conventional procedure of CT-guided biopsy, we use CT fluoroscopy for confirmation of the location of the tip of the biopsy needle and the accurate contact, in some cases, at the time of puncturing. Examination results showed malignancy in 36 lesions and benign findings in 30 lesions. The sensitivity was 85.7%, specificity was 100.0%, and accuracy was 90.9%. Pneumothorax occurred in 20 out of 64 patients (31.3%). In a study on 26 small lesions (≤2 cm) in 25 patients, the sensitivity was 81.8%, specificity was 100.0%, accuracy was 92.3%. Pneumothorax occurred in 12 out of 25 patients (48.0%), more frequently than in patients with large lesions. In a study on 6 false negative cases, they tended to be intrapulmonary on location, small in diameter, and far from the skin puncture point. Examination results were satisfactory, especially in terms of accuracy in small lesions (≤2 cm). However, when the lesions were small, pneumothorax occurred frequently (48.0%). (author)

  18. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    Science.gov (United States)

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  19. Multiparametric MRI fusion-guided biopsy for the diagnosis of prostate cancer.

    Science.gov (United States)

    Kesch, Claudia; Schütz, Viktoria; Dieffenbacher, Svenja; Bonekamp, David; Hadaschik, Boris Alexander; Hohenfellner, Markus; Radtke, Jan P

    2018-03-01

    To discuss the timing, benefits, limitations and current controversies of multiparametric magnet resonance imaging (mpMRI) combined with fusion-guided biopsy and consider how additional incorporation of multivariable risk stratification might further improve prostate cancer diagnosis. MpMRI has been proven advantageous over standard practice for biopsy-naïve men and men with previous biopsy in large prospective studies providing level 1b evidence. Upfront multivariable risk stratification followed by or combined with mpMRI further improves diagnostic accuracy. Regarding active surveillance, mpMRI in combination with fusion biopsy can support initial candidate selection and may help to monitor disease progression. mpMRI and fusion biopsy, however, do not spare failure and conflicting data exists to what extend (systematic) biopsies can be omitted. Integration of mpMRI into the diagnostic pathway for prostate cancer is beneficial; yet more prospective and randomized data is needed to establish reliable procedure standards after mpMRI acquisition.

  20. Just-in-time tomography (JiTT): a new concept for image-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pang, G; Rowlands, J A [Toronto-Sunnybrook Regional Cancer Centre, 2075 Bayview Avenue, Toronto M4N 3M5 (Canada); Imaging Research, Sunnybrook and Women' s College Health Sciences Centre, Departments of Radiation Oncology and Medical Biophysics, University of Toronto, Toronto (Canada)

    2005-11-07

    Soft-tissue target motion is one of the main concerns in high-precision radiation therapy. Cone beam computed tomography (CBCT) has been developed recently to image soft-tissue targets in the treatment room and guide the radiation therapy treatment. However, due to its relatively long image acquisition time the CBCT approach cannot provide images of the target at the instant of the treatment and thus it is not adequate for imaging targets with intrafraction motion. In this note, a new approach for image-guided radiation therapy-just-in-time tomography (JiTT)-is proposed. Differing from CBCT, JiTT takes much less time to generate the needed tomographical, beam's-eye-view images of the treatment target at the right moment to guide the radiation therapy treatment. (note)

  1. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  2. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  3. Ultrasound-guided, vacuum-assisted biopsy in evaluation of breast lesions

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Dyczek, S.; Skotnicki, P.; Stelmach, A.; Herman, K.

    2008-01-01

    Aim. Evaluation of the efficacy of ultrasound-guided vacuum-assisted biopsy for the verification of breast lesions. Introduction. Ultrasound breast examination is a noninvasive method of breast imaging. It is adjunct to mammography and physical examination and, in women under 30 years of age, pregnant and lactating, it is the basic examination used for the detection and diagnosing of breast diseases. It allows also to obtain cells or tissue samples with such minimally invasive techniques as fine-needle biopsy, core needle biopsy or vacuum-assisted biopsy. Material and methods. The study group consisted of 138 women, aged from 20 to 76 years, who underwent ultrasound guided vacuum-assisted biopsy between March and December 2006. Because double lesions were diagnosed in 6 patients, this resulted in 144 performed procedures. Each patient underwent ultrasound examination, performed with a 10-12 MHz transducer. Biopsies were guided by a 12 MHz transducer and performed with the Mammotome System using an 11G or an 8G needle, depending upon the size and site of the lesion. Obtained data were compared using the Chi-square test; p values of less than 0.05 were considered indicative of a significant difference. Results. The average size of the biopted lesions was estimated as 11±3,8 mm (range: 4-30 mm). However, lesions described by radiologists as apparently suspicious were not qualified for the vacuum-assisted biopsy, in the tested material 4 lesions appeared to be carcinomas (3 were invasive breast carcinomas and 1 was ductal carcinoma in situ). When compared with other changes, these lesions were most frequently equivocal (3 vs 1 determined as benign, p=0.014). There was no statistically significant difference in echogenicity (3 hypoechoic vs 1 with mixed echogenicity) nor in the shape (1 oval change, 2 lobulated and 1 irregular). Pathological examination revealed 86 cases of fibroadenoma within the tested material. Those lesions were mostly benign (77 vs 9 equivocal

  4. Ultrasound-guided core biopsy: an effective method of detecting axillary nodal metastases.

    LENUS (Irish Health Repository)

    Solon, Jacqueline G

    2012-02-01

    BACKGROUND: Axillary nodal status is an important prognostic predictor in patients with breast cancer. This study evaluated the sensitivity and specificity of ultrasound-guided core biopsy (Ax US-CB) at detecting axillary nodal metastases in patients with primary breast cancer, thereby determining how often sentinel lymph node biopsy could be avoided in node positive patients. STUDY DESIGN: Records of patients presenting to a breast unit between January 2007 and June 2010 were reviewed retrospectively. Patients who underwent axillary ultrasonography with or without preoperative core biopsy were identified. Sensitivity, specificity, positive predictive value, and negative predictive value for ultrasonography and percutaneous biopsy were evaluated. RESULTS: Records of 718 patients were reviewed, with 445 fulfilling inclusion criteria. Forty-seven percent (n = 210\\/445) had nodal metastases, with 110 detected by Ax US-CB (sensitivity 52.4%, specificity 100%, positive predictive value 100%, negative predictive value 70.1%). Axillary ultrasonography without biopsy had sensitivity and specificity of 54.3% and 97%, respectively. Lymphovascular invasion was an independent predictor of nodal metastases (sensitivity 60.8%, specificity 80%). Ultrasound-guided core biopsy detected more than half of all nodal metastases, sparing more than one-quarter of all breast cancer patients an unnecessary sentinel lymph node biopsy. CONCLUSIONS: Axillary ultrasonography, when combined with core biopsy, is a valuable component of the management of patients with primary breast cancer. Its ability to definitively identify nodal metastases before surgical intervention can greatly facilitate a patient\\'s preoperative integrated treatment plan. In this regard, we believe our study adds considerably to the increasing data, which indicate the benefit of Ax US-CB in the preoperative detection of nodal metastases.

  5. Computed tomography-guided bupivacaine and corticosteroid injection for the treatment of symptomatic calcification in the great toe tendon

    Directory of Open Access Journals (Sweden)

    Karatoprak O

    2014-04-01

    Full Text Available Omer Karatoprak,1 Sinan Karaca,2 Mehmet Nuri Erdem,3 Ozgur Karaman,2 Azmi Hamzaoglu41Department of Orthopedic Surgery, Kadikoy Florence Nightingale Hospital, Istanbul, Turkey; 2Department of Orthopedic Surgery, Fatih Sultan Mehmet Training and Research Hospital Atasehir, Istanbul, Turkey; 3Department of Orthopedics and Traumatology, Kolan International Hospital Sisli, Istanbul, Turkey; 4Department of Orthopedic Surgery, Istanbul Florence Nightingale Hospital, Istanbul TurkeyBackground: Calcification in the great toe tendon is a rare disorder that is characterized by the deposition of calcium on degenerative collagen fibrils.Case presentations: In this report, we present two cases of calcific tendonitis: one in the adductor hallucis and the other in the flexor hallucis longus tendon. We preferred computed tomography-guided steroid injection in our cases because of pain unresponsive to conservative treatment. Patients were free of symptoms at the follow-up visit, 4 weeks after injection.Conclusion: Calcification of the hallux tendons is a rare disorder. Treatment of tendonitis consists of nonsteroidal anti-inflammatory drugs. Local anesthetic and steroid injection may be considered in cases unresponsive to conservative treatment. Because of the anatomic location of tendons, injection could be difficult. Computed tomography guidance may improve the success rate of injections.Keywords: bupivacaine, calcification, great toe tendons, corticosteroid injection

  6. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy

    International Nuclear Information System (INIS)

    Kim, Joshua; Zhang, Tiezhi; Lu, Weiguo

    2014-01-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source–dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10–15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source–dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented. (paper)

  7. A Unique Case of Diffuse Metastatic Neuroendocrine Cancer with Subcutaneous Nodules on 18F-Fluorodeoxyglucose Positron Emission Tomography/Computer Assisted Tomography

    International Nuclear Information System (INIS)

    Johnston, Mickaila J.; Sachedina, Archana; McDonald, James E.

    2015-01-01

    Neuroendocrine tumors (NETs) account for 8–10% of cases of carcinomas of unknown primary. Most of these cases are poorly differentiated with metastatic disease at the time of diagnosis. However, cutaneous metastatic presentation is rare. We present an interesting case of a 74-year-old woman presenting with cutaneous metastatic involvement from high grade poorly differentiated NET of unknown origin. She was referred to us with a diagnosis of lymphoma. 18 F-fluorodeoxyglucose positron emission tomography/computer assisted tomography imaging at our institution offered a differential diagnosis, including neuroendocrine cancer. Repeat skin lesion biopsy demonstrated “non-Merkel cell” carcinoma, favoring metastatic high-grade neuroendocrine carcinoma

  8. The feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization for benign diseases of uterus

    International Nuclear Information System (INIS)

    Guo Wenbo; Yang Jianyong; Chen Wei; Zhuang Wenquan; Li Heping; Yao Shuzhong

    2006-01-01

    Objective: To investigate the feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization (UAE) for uterine fibroids and adenomyosis. Methods: Trans-abdominal biopsies by ultrasound guiding were performed in 62 cases of uterine fibroids or adenomyosis diagnosed pre-UAE. Multi-points in focus were punctured in single lesion and multi-points in every focus of multiple lesions were punctured. The diagnosis before UAE was made according to clinical symptoms, pelvic ultrasound and pelvic magnetic resonance imaging (MRI). The pathological diagnosis by biopsy was comparative to its clinical diagnosis before biopsy. The complications were also observed. Results: Biopsies were performed successfully in 60 cases with pathological examination, including 52 uterine fibroids and 8 adenomyosis cases. The clinical diagnosis of uterine fibroids or adenomyosis was coincident with the pathology except 2 cases of fibroids diagnosed before biopsy were failed to puncture. Conclusion: Trans-abdominal biopsy by ultrasound guiding in uterine artery embolization for benign diseases of uterus is safe and feasible. (authors)

  9. Computed tomography fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures

    International Nuclear Information System (INIS)

    Iguchi, Toshihiro; Ogawa, Ken-Ichi; Doi, Takeshi; Munetomo, Kazuo; Miyasho, Koji; Hiraki, Takao; Kanazawa, Susumu; Ozaki, Toshifumi

    2010-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of the computed tomography (CT) fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures. Six patients (four women and two men; mean age 55.8 years; range 35-77 years) with unstable posterior pelvic fractures underwent iliosacral screw placement under CT fluoroscopy guidance between November 2007 and August 2008. Unstable pelvic ring injury (AO types B and C) was the indication for this procedure. In all the six patients except one, CT fluoroscopy-guided placement had been technically successful. In one patient, a second screw had been inserted, with a tilt to the caudal site, and slightly advanced into the extrasacral body; afterward, it could be exchanged safely for a shorter screw. Five patients and one patient underwent placement of two screws and one screw, respectively. The mean duration of the procedure was 15.0 min (range 9-30 min) per screw; the duration was 12.3 min and 18.2 min for the first and second screws, respectively. No complications requiring treatment occurred during or after the procedure. The mean clinical and radiologic follow-up period was 14 months (range 6-21 months). All pelvic injuries had healed satisfactorily, without complication, and all patients are now doing well clinically and can walk. CT fluoroscopy-guided placement of iliosacral screws is a safe and effective treatment in patients with unstable posterior pelvic fractures. (orig.)

  10. Automated Real-Time Needle-Guide Tracking for Fast 3-T MR-guided Transrectal Prostate Biopsy: A Feasibility Study

    NARCIS (Netherlands)

    Zamecnik, P.; Schouten, M.G.; Krafft, A.J.; Maier, F.; Schlemmer, H.-P.; Barentsz, J.O.; Bock, M. de; Futterer, J.J.

    2014-01-01

    Purpose To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation (POCC) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. Materials and Methods This study was approved by the ethics review

  11. Value of MR-guided localization and biopsy in breast lesions; Stellenwert der MR-gestuetzten Lokalisation und Biopsie von Brustlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Grabbe, E.; Knollmann, F. [Abt. Diagnostische Radiologie, Georg-August-Univ. Goettingen (Germany)

    2006-05-15

    Contrast-enhanced dynamic MR mammography can provide important additional diagnostic information when performed for certain indications. When suspicious lesions are identified on MR mammography and cannot be reproduced using other imaging modalities, a decision must be made as to its management, i.e. further diagnostic work-up. One possibility is the short-term follow-up of such findings, resulting in higher costs and a possible delay in the start of treatment of a malignant lesion. An alternative to a follow-up is an MR-guide intervention. MR-compatible equipment has been developed for this purpose. This includes equipment specialized for percutaneous biopsy and preoperative localization. The following is an overview of the diagnostic value of MR-guided biopsy and preoperative localization including the relevant literature. (orig.)

  12. Fluorescence-Guided Probes of Aptamer-Targeted Gold Nanoparticles with Computed Tomography Imaging Accesses for in Vivo Tumor Resection.

    Science.gov (United States)

    Li, Cheng-Hung; Kuo, Tsung-Rong; Su, Hsin-Jan; Lai, Wei-Yun; Yang, Pan-Chyr; Chen, Jinn-Shiun; Wang, Di-Yan; Wu, Yi-Chun; Chen, Chia-Chun

    2015-10-28

    Recent development of molecular imaging probes for fluorescence-guided surgery has shown great progresses for determining tumor margin to execute the tissue resection. Here we synthesize the fluorescent gold nanoparticles conjugated with diatrizoic acid and nucleolin-targeted AS1411 aptamer. The nanoparticle conjugates exhibit high water-solubility, good biocompatibility, visible fluorescence and strong X-ray attenuation for computed tomography (CT) contrast enhancement. The fluorescent nanoparticle conjugates are applied as a molecular contrast agent to reveal the tumor location in CL1-5 tumor-bearing mice by CT imaging. Furthermore, the orange-red fluorescence emitting from the conjugates in the CL1-5 tumor can be easily visualized by the naked eyes. After the resection, the IVIS measurements show that the fluorescence signal of the nanoparticle conjugates in the tumor is greatly enhanced in comparison to that in the controlled experiment. Our work has shown potential application of functionalized nanoparticles as a dual-function imaging agent in clinical fluorescence-guided surgery.

  13. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  14. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  15. Computed tomography of the lungs in acquired immunodeficiency syndrome

    International Nuclear Information System (INIS)

    Hartelius, H.; Gaub, J.; Jensen, L.I.; Jensen, J.; Faber, V.; Rigshospitalet, Copenhagen

    1988-01-01

    Computed tomography of the chest was performed on 42 occasions as part of the diagnostic work-up in 26 homosexual men with, or suspected of the acquired immunodeficiency syndrome (AIDS). In 17 cases both the chest radiographs and the lung scans were abnormal, and bronchoscopy and/or lung biopsy established an etiologic diagnosis in the majority of these cases. In 9 cases CT of the lungs revealed unequivocal interstitial infiltration in the presence of a normal chest radiography, and subsequently and etiologic agent was demonstrated in all these cases. In 9 cases, patients with symptoms indicative of pulmonary infection had both a normal chest radiograph and a normal lung scan, and in none of these cases did the clinical course or additional diagnostic procedures indicate the presence of current opportunistic lung infection. CT of the lungs seems to identify accurately those patients with severe HIV-related diseases in whom invasive diagnostic procedures such as bronchoalveolar lavage and/or lung biopsy should be done. (orig.)

  16. Efficacy of ultrasonography-guided renal biopsy for the evaluation of renal dysfunction following renal transplantation

    International Nuclear Information System (INIS)

    Kim, Young Jae; Choi, Chul Soon; Min, Seon Jeong; Lee, Gyung Kyu; Lee, Eil Seong; Kang, Ik Won; Bae, Sang Hoon

    2003-01-01

    To evaluate the usefulness and complications of renal biopsy under ultrasonography-guidance in renal dysfunction after renal transplantation. Ultrasonography-guided renal biopsy was done in 47 patients with the transplanted kidney. The subjects consisted of 30 males and 17 females, age ranged from 16 to 66 years (average age=38 years). Biopsies were done once in 27 patients, twice in 17 patients, three times in 3 patients, a total of 70 biopsies. The success rate of renal biopsy for the accurate pathologic diagnosis and the incidence and types of complications following biopsy were evaluated. The success rate of renal biopsy for the accurate pathologic diagnosis was 96%(67/70). Pathologic diagnosis included 27 cases of acute rejection (39%), 8 cases of acute tubular necrosis (11%), 4 cases of acute rejection and acute tubular necrosis (6%), 4 cases of cyclosporin toxicity (6%), 4 cases of primary disease recurrence (6%), 4 cases of infection (6%) and others. Complications after renal biopsy included 15 cases of microscopic hematuria (21%), 1 case of gross hematuria with spontaneous cessation and 1 case of life threatening hemorrhage. Ultrasonography-guided renal biopsy is a safe and effective diagnostic method for the evaluation of renal dysfunction following renal transplantation.

  17. Osteoid osteomas in common and in technically challenging locations treated with computed tomography-guided percutaneous radiofrequency ablation

    International Nuclear Information System (INIS)

    Mylona, Sophia; Patsoura, Sofia; Karapostolakis, Georgios; Galani, Panagiota; Pomoni, Anastasia; Thanos, Loukas

    2010-01-01

    To evaluate the efficacy of computed tomography (CT)-guided radiofrequency (RF) ablation for the treatment of osteoid osteomas in common and in technically challenging locations. Twenty-three patients with osteoid osteomas in common (nine cases) and technically challenging [14 cases: intra-articular (n = 7), spinal (n = 5), metaphyseal (n = 2)] positions were treated with CT-guided RF ablation. Therapy was performed under conscious sedation with a seven-array expandable RF electrode for 8-10 min at 80-110 C and power of 90-110 W. The patients went home under instruction. A brief pain inventory (BPI) score was calculated before and after (1 day, 4 weeks, 6 months and 1 year) treatment. All procedures were technically successful. Primary clinical success was 91.3% (21 of total 23 patients), despite the lesions' locations. BPI score was dramatically reduced after the procedure, and the decrease in BPI score was significant (P < 0.001, paired t-test; n - 1 = 22) for all periods during follow up. Two patients had persistent pain after 1 month and were treated successfully with a second procedure (secondary success rate 100%). No immediate or delayed complications were observed. CT-guided RF ablation is safe and highly effective for treatment of osteoid osteomas, even in technically difficult positions. (orig.)

  18. Imprint cytology from ultrasound-guided core biopsies: accurate and immediate diagnosis in a one-stop breast clinic

    International Nuclear Information System (INIS)

    Jones, L.; Lott, M.F.; Calder, C.J.; Kutt, E.

    2004-01-01

    AIM: To investigate whether imprint cytology from ultrasound-guided core biopsy specimens was adequate for the National Health Service Breast Screening Programme (NHSBSP) guidelines. METHODS: We prospectively audited imprint cytology from ultrasound-guided core biopsy specimens. The performance indicators for imprint cytology specimens from 111 consecutive ultrasound-guided core biopsy were compared with standards set by the NHSBSP for fine-needle aspiration cytology (FNAC). RESULTS: Imprint cytology fulfilled the 'preferred' targets for absolute and complete sensitivity, specificity, positive predictive value, false-positive and false-negative rates, inadequate rate and inadequate rate from cancers. It also satisfied the minimum target for suspicious rate. The complete sensitivity was 97%, full specificity 78%, with 100% positive predictive value for C5 cytology and an inadequate rate from cancers of 1.5%. CONCLUSION: Imprint cytology from ultrasound-guided core biopsy allows same-day diagnosis and the collection of data regarding the grade of the carcinoma for treatment decisions from a single needle test

  19. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael, E-mail: michael.meier@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Homsi, Rami, E-mail: rami.homsi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Kukuk, Guido, E-mail: guido.kukuk@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Wolter, Karsten, E-mail: karsten.wolter@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Decker, Georges, E-mail: georges.decker@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Fischer, Stefan, E-mail: stefan.fischer@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Marx, Christian, E-mail: christian.marx@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schmeel, Frederic Carsten, E-mail: carsten.schmeel@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Block, Wolfgang, E-mail: wolfgang.block@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Sprinkart, Alois Martin, E-mail: sprinkart@uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Traeber, Frank, E-mail: frank.traeber@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Willinek, Winfried, E-mail: w.willinek@bk-trier.de [Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Hospital of the Barmherzige Brüder Trier, Nordallee 1, 54292 Trier (Germany)

    2016-12-15

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  20. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Homsi, Rami; Kukuk, Guido; Wolter, Karsten; Decker, Georges; Fischer, Stefan; Marx, Christian; Schmeel, Frederic Carsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Willinek, Winfried

    2016-01-01

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  1. Pediatric computed tomography dose of head and chest exams: a bibliography revision

    International Nuclear Information System (INIS)

    Friedrich, Barbara Q.; Capaverde, Alexandre S.; Vanni, Stefania; Mazzola, Carolina F.S.; Silva, Ana M. Marques da

    2015-01-01

    The Computed Tomography (CT) imaging diagnosis it is responsible for over 34% of the radiation dose given to society, only in Brazil there is around 3833 CT equipment. There are two dose index in CT, the CTDI vol and DLP that represents the Computed Tomography dose index and the product of the CTDI vol by the length of irradiation. This paper has as objective describe the values of CTDI vol e DLP for pediatric exams of chest and head. This is an exploratory study of bibliography revision on the PubMed data base using the index terms with the following crossing: Computed Tomography AND Reference Levels AND Dose. The search was limited by published studies on the last 5 years with patients among 0 and 15 years, in English or Portuguese. Besides that, were included references guides suggest by scientific and governmental organizations on the last 5 years. The data analysis was made using the four readings of Gil: exploratory, selective, analytic and interpretative. By the Exploratory Reading were located 23 articles. On the Selective Reading were excluded 4 articles and on the Analytic Reading 9 articles. The Interpretative Reading was made using 7 publications. Regarding the references guides were includes 3 guides. The Portaria MS453/98 was included for being the only national publication. All data were characterized between practical levels and reference levels. The conclusion is that there is no consensus between the reference levels for the selected articles, for pediatric exams. Besides that, the national legislation do not have reference levels for pediatric CT. (author)

  2. PROGNOSTIC FACTORS OF POSITIVE RESULTS OF MULTIFOCAL TRUS-GUIDED VESICOURETHRAL ANASTOMOSIS BIOPSY IN PATIENTS WITH BIOCHEMICAL RECURRENCE AFTER RADICAL PROSTATECTOMY

    Directory of Open Access Journals (Sweden)

    P. D. Demeshko

    2014-07-01

    Full Text Available Purpose. To evaluate influence of clinical, biochemical and histological factors to detection rate of local recurrence following radical prostatectomy (RPE using multifocal TRUS-guided vesicourethral anastomosis (VUA biopsy.Material and methods. 59 patients with newly diagnosed biochemical recurrence (BR after RPE were included into prospective study. All of them underwent multifocal TRUS-guided VUA biopsy. Сlinical variables (serum prostate-specifi c antigen [PSA] level and PSA kinetics, time RPE-BR, Gleason grade, stage after RPE and clinical findings were evaluated. Logistic regression and receiver operating characteristic (ROC curve analyses were performed.Results. The detection rate of local prostate recurrence with TRUS-guided VUA biopsy was 45,8 % (95 % CI 33,7–58,3. At multivariate analysis only PSA level at the moment of biopsy (≤ 1,5 ng/ml vs > 1,5 ng/ml and time RPE-BR (≤ 15 months vs > 15 months were significantly associated with positive results of multifocal TRUS-guided VUA biopsy (p < 0,05.Conclusion The detection rate of local prostate recurrence with TRUS-guided VUA biopsy depends on combination of independent predictors (PSA level at the moment of biopsy and time RPE—BR.

  3. A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.

    Science.gov (United States)

    Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I

    2017-09-01

    To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. Accuracy of biopsy needle navigation using the Medarpa system - computed tomography reality superimposed on the site of intervention

    International Nuclear Information System (INIS)

    Khan, M. Fawad; Maataoui, Adel; Gurung, Jessen; Schiemann, Mirko; Vogl, Thomas J.; Dogan, Selami; Ackermann, Hanns; Wesarg, Stefan; Sakas, Georgios

    2005-01-01

    The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54-9.51 mm) and 7.05±1.33 mm for group B (range 4.10-9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique. (orig.)

  5. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  6. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  7. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  8. Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Vienna General Hospital, Department of Radiology, Vienna (Austria); Hoffmann, Elisabeth; Schober, Ewald; Mostbeck, Gerhard [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Bernhardt, Klaus; Schalleschak, Johann [Otto Wagner Hospital, Department of Laboratory Medicine, Vienna (Austria); Rowhani, Marcel [Otto Wagner Hospital, Department of Respiratory and Critical Care Medicine, Vienna (Austria); Weber, Michael [Medical University of Vienna, Department of Radiology, Vienna (Austria)

    2011-09-15

    This study assessed the feasibility of telecytological evaluation of samples from CT-guided lung biopsies using a dynamic telecytological system in which the microscope was operated by personnel from the radiology department at the site of the biopsy and a cytologist off-site diagnosed the biopsy sample. 45 imprint samples from CT-guided biopsies of lung lesions were reviewed by two cytologists using a telecytological microscope (Olympus BX51, Tokyo, Japan). The telecytological microscope was operated by one radiologist and one radiology technician. The cytological samples were classified by a cytologist into four categories: benign, malignant, atypical cells of undetermined significance, and non-diagnostic. The results were compared with those of a previous consensus reading of two independent cytologists (gold standard). When the radiologist was operating the microscope, the diagnostic accuracy was 100% as both cytologists came to the correct diagnosis in all samples. When the technician operated the microscope, two diagnoses of cyotologist 1 differed from the gold standard. Thus, the accuracy for the technician was 95.56%. Telecytological evaluation of imprint samples from CT-guided lung biopsies is feasible because it can be performed with high diagnostic accuracy if personnel from the radiology department operate the microscope. (orig.)

  9. Proposal of a technical guide for the evaluation and management of the solitary pulmonary nodule in function of the radiological characteristics obtained by computed tomography

    International Nuclear Information System (INIS)

    Clinton Hidalgo, Carolina

    2015-01-01

    A guide is proposed to guide clinical personnel in early diagnosis, assessment and management of the solitary pulmonary nodule, with high potential of to develop lung cancer, in function of the radiological characteristics obtained by computed tomography. The management of patients with diagnosis of solitary pulmonary nodule is standardized with the purpose of to unify diagnostic criteria in a multidisciplinary and institutional environment. Tomographic radiological characteristics are described to allow the suspicion of the solitary pulmonary nodule benignity or malignity. A flow diagram is developed to guide the physician to an adequate monitoring, control and eventual therapeutic treatment. A clear and structured perspective of the diagnostic and therapeutic process is provided to the treating physician and patient [es

  10. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    International Nuclear Information System (INIS)

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L.

    2010-01-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  11. Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Joo Yeon; Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2011-02-15

    The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep ({>=} 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions {>=} 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%: group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 {+-} 4.0 minutes, 157.1 {+-} 76.5 mGy) than in group B (9.0 {+-} 3.5 minutes, 21.9 {+-} 15.2 mGy) (p < 0.05). Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions ({>=} 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose

  12. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  13. Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

    Science.gov (United States)

    Ahmad, Moiz; Balter, Peter; Pan, Tinsu

    2011-10-01

    Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4-6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3-8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm

  14. Comparative study between computed tomography and bronchoscopy in the diagnosis of lung cancer

    International Nuclear Information System (INIS)

    Oliveira, Christopher; Saraiva, Antonio

    2010-01-01

    Objective: to analyze the role of computed tomography and bronchoscopy in the diagnosis of lung cancer, evaluating the effectiveness of these techniques in the presence of this disease. Parameters such as age, gender, smoking habits, histological types, staging and treatment were also analyzed. Materials and methods: the sample of the present study included 70 patients assisted at the Department of Pneumology of Hospital Distrital da Figueira da Foz, Coimbra, Portugal, who were submitted to both diagnostic methods, namely, computed tomography and bronchoscopy, to confirm the presence or the absence of lung cancer. Results: thirty-seven patients (23 men and 14 women) were diagnosed with lung cancer. Histologically 40.54% were adenocarcinoma, followed by squamous carcinoma (32.43% cases) and small-cell lung cancer (18.92%). Staging showed 6.70% stage IB disease, 23.30% stage IIIA and 36.70% stage IIIB, and 33.30% stage IV. Chemotherapy alone was the first treatment of choice for 75.7% of patients. Bronchoscopy sensitivity was 83.8%, specificity 81.8%, and accuracy 82.8%. Computed tomography sensitivity was 81.1%, specificity 63.6%, and accuracy 72.8%. Conclusion: bronchoscopy results corroborated the relevance of the method in the diagnosis of lung cancer, considering its dependence on the anatomopathological study of tissue or cells obtained through different biopsy techniques. Computed tomography presented good sensitivity (81.1%), however the specificity of only 63.6% is related to the rate of false-positive results (36.4%). (author)

  15. Comparative study between computed tomography and bronchoscopy in the diagnosis of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Christopher; Saraiva, Antonio, E-mail: asaraiva@estescoimbra.p [Escola Superior de Tecnologia da Saude de Coimbra (ESTeSC), Coimbra (Portugal)

    2010-07-15

    Objective: to analyze the role of computed tomography and bronchoscopy in the diagnosis of lung cancer, evaluating the effectiveness of these techniques in the presence of this disease. Parameters such as age, gender, smoking habits, histological types, staging and treatment were also analyzed. Materials and methods: the sample of the present study included 70 patients assisted at the Department of Pneumology of Hospital Distrital da Figueira da Foz, Coimbra, Portugal, who were submitted to both diagnostic methods, namely, computed tomography and bronchoscopy, to confirm the presence or the absence of lung cancer. Results: thirty-seven patients (23 men and 14 women) were diagnosed with lung cancer. Histologically 40.54% were adenocarcinoma, followed by squamous carcinoma (32.43% cases) and small-cell lung cancer (18.92%). Staging showed 6.70% stage IB disease, 23.30% stage IIIA and 36.70% stage IIIB, and 33.30% stage IV. Chemotherapy alone was the first treatment of choice for 75.7% of patients. Bronchoscopy sensitivity was 83.8%, specificity 81.8%, and accuracy 82.8%. Computed tomography sensitivity was 81.1%, specificity 63.6%, and accuracy 72.8%. Conclusion: bronchoscopy results corroborated the relevance of the method in the diagnosis of lung cancer, considering its dependence on the anatomopathological study of tissue or cells obtained through different biopsy techniques. Computed tomography presented good sensitivity (81.1%), however the specificity of only 63.6% is related to the rate of false-positive results (36.4%). (author)

  16. Quality assurance procedure for a gamma guided stereotactic breast biopsy system.

    Science.gov (United States)

    Welch, Benjamin L; Brem, Rachel; Black, Rachel; Majewski, Stan

    2006-01-01

    A quality assurance procedure has been developed for a prototype gamma-ray guided stereotactic biopsy system. The system consists of a compact small-field-of-view gamma-ray camera mounted to the rotational arm of a Lorad stereotactic biopsy system. The small-field-of-view gamma-ray camera has been developed for clinical applications where mammographic X-ray localization is not possible. Marker sources that can be imaged with the gamma-camera have been designed and built for quality assurance testing and to provide a fiducial reference mark. An algorithm for determining the three dimensional location of a region of interest, such as a lesion, relative to the fiducial mark has been implemented into the software control of the camera. This system can be used to determine the three-dimensional location of a region of interest from a stereo pair of images and that information can be used to guide a biopsy needle to that site. Point source phantom tests performed with the system have demonstrated that the camera can be used to localize a point of interest to within 1 mm, which is satisfactory for its use in needle localization.

  17. Diagnostic efficacy of ultrasound-guided core-needle biopsy of peripheral lymph nodes in sarcoidosis.

    Science.gov (United States)

    Boussouar, S; Medjhoul, A; Bernaudin, J F; Tayebjee, O; Soussan, M; Uzunhan, Y; Nunes, H; Kambouchner, M; Martin, A; Valeyre, D; Brillet, P Y

    2015-09-14

    Core-needle biopsy guided by ultrasound can be performed for investigating peripheral lymph node (PLN). The aim of this study was to determine the efficacy of this technique in sarcoidosis. Retrospective review of files of all patients in the database of the radiology department of Avicenne university hospital who underwent PLN biopsies guided by ultrasound from January 2008 to June 2011 (n=292). Cases with either granulomas at histology with the procedure or with a final diagnosis of sarcoidosis were included in the study. The histological specimens were adequate in 282 out of 292 cases (96%) showing non-caseating granulomas in 22 cases (n=20 patients with a final diagnosis of sarcoidosis and n=2 patients with tuberculosis). After reviewing clinical files of the 282 patient, 22 were confirmed to have sarcoidosis, at initial presentation (n=19) or later during flare-up or relapse (n=3) with only 2 patients having no granuloma on PLN biopsy. PLN were palpable in 18 cases and only detected by (18F)FDG-PET/CT showing increased PLN uptake in 4 cases. The sensitivity and specificity of adequate biopsy were 91 and 99% and the positive and negative predictive values were 91 and 99%, respectively. Core-needle biopsy guided by ultrasound has a high efficacy for evidencing granulomas in sarcoidosis patients with PLN involvement either clinically palpable or in the presence of (18F)FDG-PET/CT uptake.

  18. CT Fluoroscopy-Guided Core Biopsy for Diagnosis of Small ({<=} 20 mm) Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hye Larn; Kim, Yoon Kyung; Woo, Ok Hee; Yong, Hwan Seok; Kang, Eun Young [Dept. of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Hyun Koo [Dept. of Thoracic Surgery, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Shin, Bong Kyung [Dept. of Pathology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2011-10-15

    To evaluate the efficacy of CT fluoroscopy-guided core biopsy of small pulmonary nodules. This study included 62 patients (35 men, 27 women; age range, 36-85 years) that had a small ({<=} 20 mm) pulmonary nodule and underwent CT fluoroscopy-guided core biopsy. The overall diagnostic accuracy and complication rate were calculated. The diagnostic accuracy was compared between two groups according to the nodule size ({<=} 10 mm vs. > 10 mm), and nodule density (solid vs. subsolid). Malignant or premalignant lesions were finally diagnosed in 39 patients; 36 true-positive and three false-negative findings (sensitivity, 92%). A benign lesion was finally diagnosed in 23 patients, with no false-positive results (specificity, 100%). The overall diagnostic accuracy was 95%. The sensitivity and diagnostic accuracy were 85% and 91% for nodules {<=} 10 mm, and 96% and 97% for nodules > 10 mm (p > 0.05). The sensitivity and diagnostic accuracy were 93% and 96% in the solid group and 90% and 92% in the subsolid group (p > 0.05). Seventeen (27%) patients had a pneumothorax and two (3%) required a closed thoracostomy. CT fluoroscopy-guided core biopsy of small pulmonary nodules yields high diagnostic accuracy with acceptable complication rates.

  19. Percutaneous computed tomography-guided ethanol injection in aldosterone-producing adrenocortical adenoma

    International Nuclear Information System (INIS)

    Rossi, R.; Savastano, S.; Tommaselli, A.P.

    1995-01-01

    The feasibility, safety and effectiveness of percutaneous computed tomography-guided ethanol injection (PEI-CT) was investigated in a patient affected by aldosterone-producing adenoma (APA). A 42-year-old male patient with typical features of hyperaldosteronism presented a solitary left adrenal adenoma measuring 2 cm, with a normal contralateral gland, evidenced by both CT scan and adrenal [ 75 Se-19]-nor-cholesterol scintigraphy. After normalization of potassium plasma levels, 4 ml of sterile 95% ethanol with 0.5 ml of 80% iothalamate sodium was injected. The procedure was completed in about 30 min. No severe pain or local complication was noted. Five hour after PEI, a fourfold and a twofold increase in aldosterone and cortisol plasma levels were observed, respectively. After 11 days on a normal sodium and potassium diet, normal potassium plasma levels and reduced aldosterone plasma levels were present, with reappearance of an aldosterone postural response. Plasma renin activity and aldosterone plasma levels normalized 1 month later, with reappearance also of a plasma renin activity postural response and maintenance of normal potassium plasma levels on a high sodium and normal potassium diet. The patient has remained hypertensive, although lower antihypertensive drug dosages have been employed. After 17 months, normal biochemical, hormonal and morphological findings were present. The authors suggested PEI-CT as a further alternative approach to surgery in the management of carefully selected patients with APA. 15 refs., 2 figs., 1 tab

  20. Magnetic resonance imaging - guided vacuum-assisted breast biopsy: an initial experience in a community hospital

    International Nuclear Information System (INIS)

    Friedman, P.; Enis, S.; Pinyard, J.

    2009-01-01

    To evaluate the effectiveness in diagnosing mammographically and sonographically occult breast lesions by using magnetic resonance imaging (MRI) guided vacuum-assisted breast biopsy in patients who presented to a community-based hospital with a newly established breast MRI program. The records of 142 consecutive patients, median age of 55 years, who had undergone MRI-guided biopsy at our institution between July 2006 and July 2007 were reviewed. From these patients, 197 mammographically and sonographically occult lesions were biopsied at the time of discovery. The pathology was then reviewed and correlated with the MRI findings. Cancer was present and subsequently discovered in 8% of the previously occult lesions (16/197) or 11% of the women studied (16/142). Of the cancerous lesions, 56% were invasive carcinomas (9/16) and 44% were ductal carcinomas in situ (7/16). Fourteen percent of the discovered lesions (28/197) were defined as high risk and included atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, and radial scar. In total, occult cancerous and high-risk lesions were discovered in 22% of the found lesions (44/197) or 31% of the women who underwent MRI-guided biopsy (44/142). This study demonstrated that detection of cancerous and high-risk lesions can be significantly increased when an MRI-guided biopsy program is introduced at a community-based hospital. We believe that as radiologists gain confidence in imaging and histologic correlation, community-based hospitals can achieve similar rates of occult lesion diagnosis as those found in data emerging from academic institutions. (author)

  1. Magnetic resonance imaging - guided vacuum-assisted breast biopsy: an initial experience in a community hospital

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, P.; Enis, S.; Pinyard, J., E-mail: jpinyard@gmail.com [Morristown Memorial Hospital, The Carol W. and Julius A. Rippel Breast Center, The Carol G. Simon Cancer Centre, Morristown, New Jersey (United States)

    2009-10-15

    To evaluate the effectiveness in diagnosing mammographically and sonographically occult breast lesions by using magnetic resonance imaging (MRI) guided vacuum-assisted breast biopsy in patients who presented to a community-based hospital with a newly established breast MRI program. The records of 142 consecutive patients, median age of 55 years, who had undergone MRI-guided biopsy at our institution between July 2006 and July 2007 were reviewed. From these patients, 197 mammographically and sonographically occult lesions were biopsied at the time of discovery. The pathology was then reviewed and correlated with the MRI findings. Cancer was present and subsequently discovered in 8% of the previously occult lesions (16/197) or 11% of the women studied (16/142). Of the cancerous lesions, 56% were invasive carcinomas (9/16) and 44% were ductal carcinomas in situ (7/16). Fourteen percent of the discovered lesions (28/197) were defined as high risk and included atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, and radial scar. In total, occult cancerous and high-risk lesions were discovered in 22% of the found lesions (44/197) or 31% of the women who underwent MRI-guided biopsy (44/142). This study demonstrated that detection of cancerous and high-risk lesions can be significantly increased when an MRI-guided biopsy program is introduced at a community-based hospital. We believe that as radiologists gain confidence in imaging and histologic correlation, community-based hospitals can achieve similar rates of occult lesion diagnosis as those found in data emerging from academic institutions. (author)

  2. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  4. False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection.

    Science.gov (United States)

    Zhou, P U; Tang, Jinliang; Zhang, Dong; Li, Guanghui

    2016-05-01

    Positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG) has been used for the staging and evaluation of recurrence in cancer patients. We herein report a false-positive result of 18 F-FDG PET/computed tomography (CT) scan in a patient following chondrosarcoma resection and metallic implanting. A 35-year-old male patient with chondrosarcoma of the left iliac bone underwent radical resection, metal brace implanting and radiotherapy. A high uptake of 18 F-FDG was observed in the metallic implants and adjacent tissue during PET/CT scanning in the 5th year of follow-up. Tissue biopsy and follow-up examination identified no tumor recurrence or infection at these sites, suggesting that the results of 18 F-FDG PET/CT must be interpreted with caution in cancer patients with metallic implants.

  5. Technical competence in cardiovascular magnetic resonance and computed tomography

    International Nuclear Information System (INIS)

    Fernandes, Juliano Lara; Shiozaki, Afonso Akio; Azevedo Filho, Clerio Francisco de; Rochitte, Carlos Eduardo; Pinto, Ibraim Marciarelli Francisco; Lopes, Marly Maria Uellendahl; Schvartzman, Paulo Roberto

    2009-01-01

    Cardiovascular magnetic resonance and computed tomography have evolved as very practical and useful techniques applied in clinical cardiology. Due to their rapid acceptance in the cardiology community and widespread use, training of both cardiologists and radiologists on this subspecialty has not been homogeneous so far. This in part explains significant differences observed in the diverse background found in today’s practicing physicians who execute these exams. In order to guide training facilities as well as both payers, contractors and general cardiologists ordering the exam, this document provides a minimum standard that should be accomplished by all physicians who pursue education in the field and for those who already practice in it. The clinical competences listed in this statement are by no means thorough but should be required by all those involved in cardiovascular magnetic resonance and computed tomography as the customary requirements for current and future practitioners. (author)

  6. Usefulness of transrectal ultrasound-guided 12 core biopsy method in patients with clinically suspected prostate cancer

    International Nuclear Information System (INIS)

    Kwon, Se Hwan; Lim, Joo Won; Park, Seong Jin; Ko, Young Tae; Kim, Yoon Wha

    2000-01-01

    To evaluate the improvement of prostate cancer detection provided by transrectal ultrasound (TRUS)-guided 12 core biopsy method compared with sextant biopsy method. Between June 1997 and February 1999, 29 patients with pathologically proven prostate cancer in 124 patients who underwent TRUS-guided 12 core biopsy method were evaluated. They had abnormal findings in prostate specific antigen (PSA), digital rectal examination (DRE) or TRUS findings. The prostate was diffusely enlarged in all patients on DRE findings and in 15 cases (15/29, 52%), hard nodule was palpated. The average of PSA and prostate specific antigen density (PSAD) is 229.33 ng/ml (1-2280) and 9.14 ng/ml/cm 3 (0.048-142.5), respectively, 12 transrectal biopsy, including 2 transition zones, was performed in both lobe, 6 biopsies were located in both base, middle and apex. Then 2 biopsies were inserted between 3 biopsies in both peripheral zone and 2 biopsies were performed in both transition zone. Each specimen was pathologically examined. The results of pathology were compared with method 1 and 2, respectively. We defined the method 1 and 2 as different sextant biopsy method. The method 1 is that cores are taken from both base, middle and apex and method 2 is that cores are taken from both base, apex and transition zone. TRUS findings were analyzed by two radiologists. Of the 29 patients with prostate cancer, 3 (10%) had carcinomas only in the additional regions as compared with method. When compared with method 2,2 (7.0%) had carcinomas only in the additional regions. 2 patients were same in both cases. TRUS findings were abnormal in 21 cases in all patients whose 12 biopsy method was not helpful. 12 biopsy method was helpful in 2/8 (25%) whose TRUS findings were non-specific and 1/21 (4.8%) whose TRUS findings were abnormal. Small low echoic lesion was seen in one patients whose 12 biopsy method was helpful, but cancer was found in other area. TRUS-guided 12 core biopsy method may be superior to

  7. Computed tomography-guided interstitial high dose rate brachytherapy for centrally located liver tumours: a single institution study

    Energy Technology Data Exchange (ETDEWEB)

    Tselis, Nikolaos; Chatzikonstantinou, Georgios; Zamboglou, Nikolaos [Klinikum Offenbach, Department of Radiation Oncology, Offenbach am Main (Germany); Kolotas, Christos [Hirslanden Medical Center, Institute for Radiotherapy, Aarau (Switzerland); Milickovic, Natasa; Baltas, Dimos [Klinikum Offenbach, Department of Medical Physics and Engineering, Offenbach am Main (Germany)

    2013-08-15

    To evaluate the clinical outcome of computed tomography (CT)-guided interstitial (IRT) high-dose-rate (HDR) brachytherapy (BRT) in the treatment of unresectable primary and secondary liver malignancies. This report updates and expands our previously described experience with this treatment technique. Forty-one patients with 50 tumours adjacent to the liver hilum and bile duct bifurcation were treated in 59 interventions of CT-guided IRT HDR BRT. The tumours were larger than 4 cm with a median volume of 84 cm{sup 3} (38-1,348 cm{sup 3}). The IRT HDR BRT delivered a median total physical dose of 20.0 Gy (7.0-32.0 Gy) in twice daily fractions of median 7.0 Gy (4.0-10.0 Gy) in 19 patients and in once daily fractions of median 8.0 Gy (7.0-14.0 Gy) in 22 patients. With a median follow-up of 12.4 months, the local control for metastatic hepatic tumours was 89 %, 73 % and 63 % at 6, 12 and 18 months respectively. The local control for primary hepatic tumours was 90 %, 81 % and 50 % at 6, 12 and 18 months respectively. Severe side effects occurred in 5.0 % of interventions with no treatment-related deaths. CT-guided IRT HDR BRT is a promising procedure for the radiation treatment of centrally located liver malignancies. (orig.)

  8. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  9. Diagnostic Accuracy of Robot-Guided, Software Based Transperineal MRI/TRUS Fusion Biopsy of the Prostate in a High Risk Population of Previously Biopsy Negative Men

    Directory of Open Access Journals (Sweden)

    Malte Kroenig

    2016-01-01

    Full Text Available Objective. In this study, we compared prostate cancer detection rates between MRI-TRUS fusion targeted and systematic biopsies using a robot-guided, software based transperineal approach. Methods and Patients. 52 patients received a MRIT/TRUS fusion followed by a systematic volume adapted biopsy using the same robot-guided transperineal approach. The primary outcome was the detection rate of clinically significant disease (Gleason grade ≥ 4. Secondary outcomes were detection rate of all cancers, sampling efficiency and utility, and serious adverse event rate. Patients received no antibiotic prophylaxis. Results. From 52 patients, 519 targeted biopsies from 135 lesions and 1561 random biopsies were generated (total n=2080. Overall detection rate of clinically significant PCa was 44.2% (23/52 and 50.0% (26/52 for target and random biopsy, respectively. Sampling efficiency as the median number of cores needed to detect clinically significant prostate cancer was 9 for target (IQR: 6–14.0 and 32 (IQR: 24–32 for random biopsy. The utility as the number of additionally detected clinically significant PCa cases by either strategy was 0% (0/52 for target and 3.9% (2/52 for random biopsy. Conclusions. MRI/TRUS fusion based target biopsy did not show an advantage in the overall detection rate of clinically significant prostate cancer.

  10. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    International Nuclear Information System (INIS)

    Wallace, Adam N.; Pacheco, Rafael A.; Tomasian, Anderanik; Hsi, Andy C.; Long, Jeremiah; Chang, Randy O.; Jennings, Jack W.

    2016-01-01

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact

  11. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Hsi, Andy C., E-mail: hsia@path.wustl.edu [Washington University School of Medicine, Division of Anatomic Pathology, Department of Pathology & Immunology (United States); Long, Jeremiah, E-mail: longj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Chang, Randy O., E-mail: changr@wusm.wustl.edu [Washington University School of Medicine (United States); Jennings, Jack W., E-mail: jenningsj@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-02-15

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.

  12. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  13. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  14. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  15. Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients: A Case Report.

    Science.gov (United States)

    Oh, Ji-Hyeon; An, Xueyin; Jeong, Seung-Mi; Choi, Byung-Ho

    2017-12-01

    The purpose of this article was to describe a fully digital workflow used to perform computer-guided flapless implant placement in an edentulous patient without the use of conventional impressions, models, or a radiographic guide. Digital data for the workflow were acquired using an intraoral scanner and cone-beam computed tomography (CBCT). The image fusion of the intraoral scan data and CBCT data was performed by matching resin markers placed in the patient's mouth. The definitive digital data were used to design a prosthetically driven implant position, surgical template, and computer-aided design and computer-aided manufacturing fabricated fixed dental prosthesis. The authors believe this is the first published case describing such a technique in computer-guided flapless implant surgery for edentulous patients. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. MR-guided biopsies of undetermined liver lesions: technique and results; MRT-gezielte perkutane Biopsie bei unklaren fokalen Leberlaesionen: Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, S.; Kiefl, D.; Eichler, K.; Engelmann, K.; Heller, M.; Herzog, C.; Mack, M.G.; Jacobi, V.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Univ. Frankfurt (Germany)

    2003-05-01

    Purpose: To evaluate safety and precision of liver tumor biopsies performed in an open low field system using different sequence techniques. Materials and Methods: In 47 patients with liver tumors, MR-guided biopsies were performed in a low field system (0.2 Tesla, Magnetom Open, Siemens) using two different sequences. The procedure was monitored with T1-weighted FLASH sequences (TR/TE = 100/9; 70 ) in all patients and with FISP-Rotated-Keyhole-sequence (TR/TE = 18/8; 90 ) in additional 20 patients. After positioning of the needle tip in the tumors, 166 biopsy specimens were acquired with 16 G cutting needles (Somatex{sup *}). The diameter of the biopsied lesions ranged from 1 to 10 cm (mean diameter 3.2 cm). Visibility of the needles and precision of the biopsies were evaluated. Results: All interventional biopsies were performed without vascular or organ injuries. Adequate specimens for histologic interpretation were obtained in 42 cases (89.3%). The biopsy results were non-specific in 2 patients (4.2%) and the lesions missed in 3 patients (6.3%). Mean in-room time was 35 minutes and the intervention time was 8.3 minutes. T1-weighted FLASH images proved optimal for confirming needle-tip placement during the biopsies or punctures. Organs, tumors and vessels were easily identified. The FISP sequence proved to be inferior in visualizing vessels and tumors. Conclusion: MR-guided liver biopsies are safely and precisely performed using T1-weighted FLASH-sequences with sufficient visualization of the lesions and might be complementary to US- or CT-guided biopsies. (orig.) [German] Zielsetzung: Evaluierung der Sicherheit und Genauigkeit MRT-gezielter Leberbiopsien unter Verwendung verschiedener Sequenzen. Methoden: Bei 47 Patienten mit unklaren Leberlaesionen wurden in einem offenen 0,2-Tesla-MR-System (Magnetom Open, Siemens) bildgesteuerte Biopsien unter Verwendung von zwei verschiedenen Sequenzen durchgefuehrt. Die Bildgebung erfolgte bei allen Patienten mittels T

  17. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  18. Complete removal of a breast mass by US-guided mammotome biopsy: histologic assessment by marginal sampling

    International Nuclear Information System (INIS)

    Kim, Youn Jeong; Choi, Hye Young; Moon, Byung In; Lee, Shi Nae

    2005-01-01

    The aim of this study was to assess whether the complete removal of a breast mass using ultrasound (US) guided mammotome biopsy was successful using a marginal biopsy after insuring the total visual excision of the breast mass on US images. The relationship of complete breast mass removal, and the hematoma, mass size and shape were also evaluated. A US guided mammotome biopsy was performed in a total of 136 cases in 133 patients, with marginal biopsies also added when the complete removal of breast mass had been identified by sonography. The results of the marginal biopsies were serially dividing into three groups, as follows: group I were the cases in the initial 6 months, group II after the initial 6 months and group III having undergone two marginal biopsies. The marginal biopsies were performed in four directions around the probe, with 'marginal positivity' defined as the same histopathological findings to that of the main mass in at least one direction. A statistical analysis was also used to evaluate between the marginal positivity and the hematoma, mass size and shape. The marginal positivities of groups I, II and III were 48.8, 29.4 and 45.5%, respectively. The marginal positivity of those with a lobular shaped mass was significantly higher (ρ = 0.0121) than those with round or oval shaped masses (61.5 vs 33.7 vs 50%), but showed no statistical relationship with hematoma size of the lesions. Although the lesions were removed by US using a US-guided mammotome biopsy, many residual lesions were still histologically present in the marginal samplings, especially in the lobular shaped masse

  19. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Eun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cho, Nariya [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Centre, Institute of Radiation Medicine, Seoul (Korea, Republic of); Han, Wonshik [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of)

    2017-12-15

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  20. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    International Nuclear Information System (INIS)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-01-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  1. Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions

    International Nuclear Information System (INIS)

    Clevert, D.A.; Helck, A.; Paprottka, P.M.; Trumm, C.; Reiser, M.F.; Zengel, P.

    2012-01-01

    Abdominal ultrasound is often the first-line imaging modality for assessing focal liver lesions. Due to various new ultrasound techniques, such as image fusion, global positioning system (GPS) tracking and needle tracking guided biopsy, abdominal ultrasound now has great potential regarding detection, characterization and treatment of focal liver lesions. Furthermore, these new techniques will help to improve the clinical management of patients before and during interventional procedures. This article presents the principle and clinical impact of recently developed techniques in the field of ultrasound, e.g. image fusion, GPS tracking and needle tracking guided biopsy and discusses the results based on a feasibility study on 20 patients with focal hepatic lesions. (orig.) [de

  2. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    Science.gov (United States)

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  3. Percutaneous CT-guided sacroiliac joint sampling for infection. Aspiration, biopsy, and technique

    Energy Technology Data Exchange (ETDEWEB)

    Knipp, David; Simeone, F.J.; Huang, Ambrose J.; Chang, Connie Y. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Nelson, Sandra B. [Massachusetts General Hospital, Infectious Disease Unit, Department of Medicine, Boston, MA (United States)

    2018-04-15

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning. (orig.)

  4. Prospective evaluation of fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) for axillary staging in breast cancer

    International Nuclear Information System (INIS)

    Yamaguchi, Masahide; Noguchi, Akinori; Tani, Naoki

    2008-01-01

    Seventy-two patients from 2005 October to 2007 February with operative breast cancer underwent fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) of chest and body, ultrasound scan (US) and enhanced computed tomography scan (CT) followed by sentinel lymph node biopsy (SLNB) and axillary lymph node dissection (ALND). The results of PET/CT were compared with histopathological diagnosis of SLNB and ALND. Sensitivity, specificity and accuracy of PET/CT for detection of axillary lymph node metastases were 61%, 96% and 88%, respectively. Seven false-negative and two false-positive of PET/CT results were found. In patients with false-negative of PET/CT results there are two skin-invasive breast cancer patients and axillary lymph node metastases were detected in three patients with US, in one with CT and in four with SLNB. In clinical method for diagnosis of axillary lymph node metastases SLNB should be recommended because sensitivity of PET/CT for early breast cancer patients were low and positive diagnosis of axillary lymph node metastases with PET needs more than 1 cm size of lesion. PET/CT is useful for not-early breast cancer patients. To decide the operation of axillary lymph node disection needs total diagnosis of US, CT, SLNB and clinical findings. (author)

  5. Renal imaging with radionuclides, ultrasound, and computed tomography

    International Nuclear Information System (INIS)

    Kahn, P.C.

    1979-01-01

    Nuclear medicine, ultrasound, and computed tomography have all contributed greatly to the diagnosis and understanding of renal disease. The /sup 99m/Tc-glucoheptonate scan is a multipurpose test for evaluating blood flow, cortical function and excretion, and the location of renal tissue. It is especially useful in renal trauma and vascular disease, congenital anomalies, and pseudomasses. Technetium-99m diethylene triamine pentaacetic acid (DTPA) is most helpful in evaluating obstruction and reflux, and 67 Ga citrate has a major role in inflammatory disease. The gray-scale ultrasound examination helps to characterize masses as cysts, abscesses, or tumors, and is particularly helpful in localization for aspiration, biopsy, or drainage procedures. Its total innocuousness makes echography useful for sequential follow-up in hydronephrosis and masses. Computed tomography with a fast scanner allows the identification of small lesions, and gives the most anatomic information. It permits the differentiation of fat from pelvic tumors and small cysts from neoplasms, and clearly identifies perirenal structures. With contrast enhancement, additional information about the vascularity of lesions is obtained. Although these tests use different physical principles and instruments, the data they provide are often similar, and for practical purposes the use of one modality may preclude the use of others. Difficult judgments are required to make certain that the proper examination or sequence of examinations is done in each case

  6. Comparative cost-effectiveness of fine needle aspiration biopsy versus image-guided biopsy, and open surgical biopsy in the evaluation of breast cancer in the era of Affordable Care Act: a changing landscape.

    Science.gov (United States)

    Masood, Shahla; Rosa, Marilin; Kraemer, Dale F; Smotherman, Carmen; Mohammadi, Amir

    2015-08-01

    Proven as a time challenged and cost-effective sampling procedure, the use of FNAB has still remained controversial among the scientific community. Currently, other minimally invasive sampling procedures such as ultrasound guided fine needle aspiration biopsy (US-FNAB) and image guided core needle biopsy (IG-CNB) have become the preferred sampling procedures for evaluation of breast lesions. However, changes in the medical economy and the current growing emphasis on cost containment in the era of the Affordable Care Act make it necessary to stimulate a renewed interest in the use of FNAB as the initial diagnostic sampling procedure. This study was designed to define the changing trend in the practice of tissue sampling during the last several years, and to assess the comparative effectiveness and appropriateness of the procedure of choice for breast cancer diagnosis. After Institutional Review Board (IRB) approval, the computer database of the Pathology Department, University of Florida, College of Medicine-Jacksonville at UF Health was retrospectively searched to identify all breast biopsy pathology reports issued during the period of January 2004 to December 2011. The inclusion criteria were all women that underwent any of the following biopsy types: FNAB, US-FNAB, IG-CNB, and surgical biopsy (SB). Diagnostic procedures were identified using current procedural terminology (CPT) codes recorded on claims from the UF Health Jacksonville patient accounting application files. The data obtained was used to determine which technique has the best cost-effectiveness in the diagnosis of breast cancer. The outcome variable for this project was a positive breast cancer diagnosis resulting from these methodologies. The predictor variable was the biopsy type used for sampling. The rate of cancer detection for each procedure was also determined. Among the four groups of procedures compared, the lower cost was attributed to FNAB, followed by US-FNAB, and SB. IG-CNB was the most

  7. Prospective, blinded trial of whole-body magnetic resonance imaging versus computed tomography positron emission tomography in staging primary and recurrent cancer of the head and neck.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-02-01

    OBJECTIVES: To compare the use of computed tomography - positron emission tomography and whole-body magnetic resonance imaging for the staging of head and neck cancer. PATIENTS AND METHODS: From January to July 2009, 15 consecutive head and neck cancer patients (11 men and four women; mean age 59 years; age range 19 to 81 years) underwent computed tomography - positron emission tomography and whole-body magnetic resonance imaging for pre-therapeutic evaluation. All scans were staged, as per the American Joint Committee on Cancer tumour-node-metastasis classification, by two blinded consultant radiologists, in two sittings. Diagnoses were confirmed by histopathological examination of endoscopic biopsies, and in some cases whole surgical specimens. RESULTS: Tumour staging showed a 74 per cent concordance, node staging an 80 per cent concordance and metastasis staging a 100 per cent concordance, comparing the two imaging modalities. CONCLUSION: This study found radiological staging discordance between the two imaging modalities. Whole-body magnetic resonance imaging is an emerging staging modality with superior visualisation of metastatic disease, which does not require exposure to ionising radiation.

  8. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    International Nuclear Information System (INIS)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca; Facciorusso, Domenico; Decembrino, Francesco; Attino, Vito; Bisceglia, Michele

    2002-01-01

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yielded no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)

  9. Fast-track, ambulatory ultrasound-guided Tru-Cut liver biopsy is feasible and cost-efficient

    DEFF Research Database (Denmark)

    Huang, Chenxi; Lorentzen, Torben; Skjoldbye, Bjørn

    2015-01-01

    INTRODUCTION: Most institutions perform percutaneous liver biopsy with a post-biopsy patient observation period lasting up to eight hours, which is resource-demanding. This study aimed to evaluate the safety of liver biopsy performed in a fast-track set-up with an only one-hour post......-biopsy observation time. METHODS: Patients referred to our institution underwent fast-track ultrasound-guided 18-gauge Tru-Cut liver biopsy procedures. Each single biopsy procedure was followed by a post-procedure observational period of one hour and an additional focused assessment with sonography for trauma before...... safely discharged from our institution. No fatality or long-term complications were found during this study. CONCLUSION: The fast-track approach reported herein is a feasible option when adequate patient information is given. Besides the obvious, positive effect on patient logistics and departmental...

  10. Preliminary experience with interactive guided brain biopsies using a vertically opened 0.5-T MR system

    International Nuclear Information System (INIS)

    Schneider, J.P.; Dietrich, J.; Lieberenz, S.; Schmidt, F.; Sorge, O.; Trantakis, C.; Seifert, V.; Kellermann, S.; Schober, R.; Franke, P.

    1999-01-01

    The purpose of our study was to evaluate the feasibility and accuracy of brain biopsies performed within a vertically opened MR system. We worked with the interventional 0.5-T MR ''SIGNA SP'' (General Electric Medical Systems, Milwaukee, Wis.) with an integrated tracking device ''Flashpoint Position Encoder'' (Image Guided Technologies, USA). As a holding device for this instrument we constructed a special frame. The whole system allows an exact adjustment of an optimum biopsy direction and guidance of the biopsy in a non-stereotactic, interactive mode in near real-time. As biopsy tools we used MR-compatible aspiration and specially made side-cut needles (Daum, Germany; E-Z-EM, USA). We performed a prospective diagnostic brain biopsy study in 18 patients. Guidance of the needle was carried out using gradient-echo single-slice technique. The sample was taken after controlling the exact position of the needle tip on spin-echo images. In 12 cases an exact neuropathological diagnosis was possible. In 6 cases of negative biopsy (4 aspiration biopsies) the samples were not representative. Our results demonstrate the feasibility of interactive MR-guided minimally invasive brain biopsies in an open MR system. The best results were achieved using cut needles for biopsies of contrast-enhancing lesions visible on T1-weighted gradient-echo guidance sequence. (orig.)

  11. Influence able and Avoidable Risk Factors for Systemic Air Embolism due to Percutaneous CT-Guided Lung Biopsy: Patient Positioning and Coaxial Biopsy Technique-Case Report, Systematic Literature Review, and a Technical Note

    International Nuclear Information System (INIS)

    Rott, G.; Boecker, F.

    2014-01-01

    Following the first case of a systemic air embolism due to percutaneous CT-guided lung biopsy in our clinic we analysed the literature regarding this matter in view of influence able or avoidable risk factors. A systematic review of literature reporting cases of systemic air embolism due to CT-guided lung biopsy was performed to find out whether prone positioning might be a risk factor regarding this issue. In addition, a technical note concerning coaxial biopsy practice is presented. Prone position seems to have relevance for the development and/or clinical manifestation of air embolism due to CT-guided lung biopsy and should be considered a risk factor, at least as far as lesions in the lower parts of the lung are concerned. Biopsies of small or cavitary lesions in coaxial technique should be performed using a hemo static valve.

  12. Computed tomography findings of early abdominal postoperative complications

    International Nuclear Information System (INIS)

    Zissin, R.; Osadchy, A.; Gayer, G.

    2007-01-01

    Various surgical approaches are used for different abdominal pathological conditions. Postoperative complications occur not infrequently and vary according to the type of the surgery and the clinical context. Nowadays, multidetector computed tomography (MDCT) provides superb anatomic detail and diagnostic accuracy for various intraabdominal pathological processes, even if clinically unsuspected, and it thus has become an essential diagnostic tool for evaluating postoperative insults. Other advantages of abdominal MDCT include its accessibility and its speed, which allow scanning of uncooperative, marginally stable patients. Computed tomography (CT)-guided percutaneous (PC) drainage of postoperative collections is another advantage of CT. Therefore, although CT requires transportation of a critically ill, postoperative patient, it is recommended in any suspicious clinical setting because several conditions require prompt management and a correct diagnosis is crucial. In assessing a patient for suspected postoperative complications, several points should be taken into consideration, including the relevant clinical and laboratory data, the surgical findings, the type of the surgery, the time elapsed since surgery, and the operative technique (either open laparotomy of laparoscopic procedure). (author)

  13. The Amyand's Hernia: A Rare Clinical Entity Diagnosed by Computed Tomography.

    Science.gov (United States)

    Keskin, Suat; Simşek, Cihan; Keskin, Zeynep

    2013-01-01

    Amyand's hernia, named for the first person to describe an inguinal hernia containing the vermiform appendix, is an uncommon variant of an inguinal hernia. Amyand's hernia is an extremely rare condition and is often misdiagnosed. Traditionally, these hernias have been diagnosed at surgery but are increasingly diagnosed by abdominal computed tomography (CT) scans. CT of the abdomen may help in guiding the diagnosis.

  14. Application of CT-guided percutaneous thyroid biopsy in basic study of interventional therapy for Graves disease

    International Nuclear Information System (INIS)

    Yi Genfa; Zhao Wei; Hu Jihong; Jin Cangzheng; Yang Huiying

    2007-01-01

    Objective: To evaluate the value of application of CT-guided percutaneous thyroid biopsy in basic study of interventional treatment for Graves disease. Methods: Fifteen patients of hyperthyroidism caused by Graves' disease had been undertaken transcathter arterial embolizsation with PVA micropheres including 52 core needle biopsy(CNB)of pre-or post-interventional procedure. All procedures were divided into 2 groups according to the size of the thyroid enlargement: (1) II degree enlargement (n=19)under palpation puncture. (2) No enlargement or under II degree enlargement (n=33)with palpation and CT-guided puncture. Results: In group (1), 17 of the 19 procedures with palpation puncture were succeeded, reaching a successful rate of 89.5%. For group (2), the successful rate of CT-guided puncture was 91.7%. The difference between the successful rate of two groups showed statistical significance (P<0.05). No complication occurred during procedures in all cases. Conclusions: CT-guided thyroid core needle biopsy is an accurate, safe and high successful procedure providing the basic study for post-interventional treatment of Graves disease. (authors)

  15. CT-Guided Biopsy in Suspected Spondylodiscitis--The Association of Paravertebral Inflammation with Microbial Pathogen Detection.

    Directory of Open Access Journals (Sweden)

    Daniel Spira

    Full Text Available To search for imaging characteristics distinguishing patients with successful from those with futile microbiological pathogen detection by CT-guided biopsy in suspected spondylodiscitis.34 consecutive patients with suspected spondylodiscitis underwent CT-guided biopsy for pathogen detection. MR-images were assessed for inflammatory infiltration of disks, adjacent vertebrae, epidural and paravertebral space. CT-images were reviewed for arrosion of adjacent end plates and reduced disk height. Biopsy samples were sent for microbiological examination in 34/34 patients, and for additional histological analysis in 28/34 patients.Paravertebral infiltration was present in all 10/10 patients with positive microbiology and occurred in only 12/24 patients with negative microbiology, resulting in a sensitivity of 100% and a specificity of 50% for pathogen detection. Despite its limited sensitivities, epidural infiltration and paravertebral abscesses showed considerably higher specificities of 83.3% and 90.9%, respectively. Paravertebral infiltration was more extensive in patients with positive as compared to negative microbiology (p = 0.002. Even though sensitivities for pathogen detection were also high in case of vertebral and disk infiltration, or end plate arrosion, specificities remained below 10%.Inflammatory infiltration of the paravertebral space indicated successful pathogen detection by CT-guided biopsy. Specificity was increased by the additional occurrence of epidural infiltration or paravertebral abscesses.

  16. Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.

    Science.gov (United States)

    Farley, Nathaniel E; Kennedy, Kelly; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Recent clinical studies have shown that implant placement is highly predictable with computer-generated surgical guides; however, the reliability of these guides has not been compared to that of conventional guides clinically. This study aimed to compare the accuracy of reproducing planned implant positions with computer-generated and conventional surgical guides using a split-mouth design. Ten patients received two implants each in symmetric locations. All implants were planned virtually using a software program and information from cone beam computed tomographic scans taken with scan appliances in place. Patients were randomly selected for computer-aided design/computer-assisted manufacture (CAD/CAM)-guided implant placement on their right or left side. Conventional guides were used on the contralateral side. Patients underwent operative cone beam computed tomography postoperatively. Planned and actual implant positions were compared using three-dimensional analyses capable of measuring volume overlap as well as differences in angles and coronal and apical positions. Results were compared using a mixed-model repeated-measures analysis of variance and were further analyzed using a Bartlett test for unequal variance (α = .05). Implants placed with CAD/CAM guides were closer to the planned positions in all eight categories examined. However, statistically significant differences were shown only for coronal horizontal distances. It was also shown that CAD/CAM guides had less variability than conventional guides, which was statistically significant for apical distance. Implants placed using CAD/CAM surgical guides provided greater accuracy in a lateral direction than conventional guides. In addition, CAD/CAM guides were more consistent in their deviation from the planned locations than conventional guides.

  17. CT-guided percutaneous transthoracic aspiration biopsy of lung lesions: factors influencing the diagnostic accuracy

    International Nuclear Information System (INIS)

    Huang Zhenguo; Zhang Xuezhe; Wang Wu

    2006-01-01

    Objective: To investigate the factors influencing the diagnostic accuracy in CT-guided percutaneous transthoracic aspiration biopsy of lung lesions. Methods: CT-guided percutaneous transthoracic biopsy was performed in 435 patients with surgical pathologic confirmation or clinical follow-up. Univariant statistical analysis and multivariant stepwise Logistic regression analysis were used to study the influence of lesion-related factors (benignancy or malignancy, size, location, depth, presence of cavity), procedure factors (laser-guidance, position of patient) and patient-related factors (sex, age, presence of emphysema); with the accuracy of the diagnosis. Results: 1)289 lesions were diagnosed as malignant ones and 146 as benign ones. The accuracy of CT-guided biopsy was 83.4%(363/435). Univariant analysis showed that the diagnostic accuracies for malignant and benign lesions were 88.9%(257/289) and 72.6%(106/146), respectively (χ 2 =18.71, P=0.00002). Laser-group was superior to non-laser group (88.4% versus 80.9%, respectively, χ 2 =4.00, P=0.0456). Mean diameters of lesions in correct diagnostic group and non-correct diagnostic group were 3.78±1.64 cm and 3.02±1.26 cm, respectively (F=13.79, P=0.0002). 2)Multivariant stepwise Logistic regression analysis showed that among the various factors influencing the final benign or malignant diagnoses (Wald χ 2 =14.01, P=0.0002) and using laser-guidance(Wald χ 2 =3.92, P=0.0477) were significantly associated with the diagnostic accuracy. Conclusions: Final correct diagnoses (benign, malignant) are closely related to the application of laser-guidance for determining the diagnostic accuracy in CT-guided transcutaneous thoracic needle aspiration biopsy. (authors)

  18. Creating vascular models by postprocessing computed tomography angiography images: a guide for anatomical education.

    Science.gov (United States)

    Govsa, Figen; Ozer, Mehmet Asim; Sirinturk, Suzan; Eraslan, Cenk; Alagoz, Ahmet Kemal

    2017-08-01

    A new application of teaching anatomy includes the use of computed tomography angiography (CTA) images to create clinically relevant three-dimensional (3D) printed models. The purpose of this article is to review recent innovations on the process and the application of 3D printed models as a tool for using under and post-graduate medical education. Images of aortic arch pattern received by CTA were converted into 3D images using the Google SketchUp free software and were saved in stereolithography format. Using a 3D printer (Makerbot), a model mode polylactic acid material was printed. A two-vessel left aortic arch was identified consisting of the brachiocephalic trunk and left subclavian artery. The life-like 3D models were rotated 360° in all axes in hand. The early adopters in education and clinical practices have embraced the medical imaging-guided 3D printed anatomical models for their ability to provide tactile feedback and a superior appreciation of visuospatial relationship between the anatomical structures. Printed vascular models are used to assist in preoperative planning, develop intraoperative guidance tools, and to teach patients surgical trainees in surgical practice.

  19. Laparoscopic and Percutaneous Core Needle Biopsy Plays a Central Role for the Diagnosis of Autoimmune Pancreatitis in a Single-Center Study from Denmark

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Mortensen, Michael Bau; Kjærulf Pless, Torsten

    2015-01-01

    organ involvement was observed in 40% of type 1 and 13% of type 2, but inflammatory bowel disease only in type 2 (P = 0.001). One patient had IgG4-related chronic perisplenitis as a hitherto undescribed manifestation of IgG4-related disease. Nineteen (91%) of 21 biopsied patients had diagnostic CNB...... Hospital from 2007 to 2013 were included (n = 30; mean follow-up, 26.2 months). Data from laparoscopic or percutaneous ultrasound-guided core needle biopsy (CNB), resection specimens, endoscopic ultrasound (EUS), EUS-guided CNB, computed tomography, serum immunoglobulin G4 (IgG4), and pancreatography were...... retrospectively analyzed according to ICDC. RESULTS: Twenty patients were diagnosed with type 1, 8 with type 2, and 2 with not otherwise specified AIP. Twenty-eight patients (93%) could correctly be classified when ICDC were retrospectively applied. Serum IgG4 was elevated in 44% of type 1 and 0% of type 2. Other...

  20. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, Stephan [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany); Johann Wolfgang Goethe-University, Institute for Diagnostic and Interventional Radiology, Frankfurt/Main (Germany); Eichler, Katrin; Engelmann, Kerstin; Ahmed, Mukhtiar; Dettmer, Sebastian; Herzog, Christopher; Pegios, Wasilios; Wetter, A.; Lehnert, Thomas; Mack, Martin G.; Vogl, Thomas J. [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany)

    2005-01-01

    The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions. (orig.)

  1. Central lung tumors with obstructive pneumonitis; ultrasonographic findings and usefulness of ultrasound-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong An; Kim, Sun Su; Seon, Young Seok; Lee, Kyoung Rok; Kim, Byoung Geun; Park, Byung Ran; Kim, Se Jong [Kwangju Christian Hospital, Kwangju (Korea, Republic of)

    2001-02-01

    To determine the ultrasonographic findings and assess the usefulness of ultrasound (US)-guided biopsy of central lung tumors in patients with obstructive pneumonitis. Fourteen patients with central lung tumors causing obstructive pneumonitis, as seen on chest radiographs and chest CT scans, were examined between January 1997 and January 2000. In no patient conclusive histologic diagnosis obtained by means of bronchoscopic biopsy or sputum cytology. Eleven patients were men and three were women, and their ages ranged from 45 to 83 (mean, 64) years. For all examinations, real-time, linear-array, convex US units with a 3.75-and a 5.0-MHz transducer were used. The images obtained were analyzed for evidence of consolidation or atelectasis in the lung, demonstrable tumors, and tumor size and echogenicity. For US-guided percutaneous transthoracic biopsy, 19.5G automatic biopsy devices, were employed. Lung consolidation due to a wedge-shaped, homogeneous, hypoechoic lesion was revealed by sonographic fluid bronchograms, air bronchograms, air alvelograms, and visualization of intraparenchymal pulmonary vessels, which showed appropriate motion with respiration. The tumor presumed to be causing obstruction was seen as a hypoechoic nodule near the hilum or as a well-defined hyperechoic mass inside the partially consolidated lung. Pleural effusion was observed in one case. The cytologic findings indicated the presence of squamous cell carcinoma (n=4), adenocarcinoma (n=4), small cell carcinoma (n=3), non-small cell carcinoma (n=2) and large cell carcinoma (n=1). The success rate was 100%, and there were no complications. In patients with central lung tumors causing obstructive pneumonitis, chest ultrasonography and US-guided biopsy are useful adjunctive diagnostic modalities and techniques.

  2. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  3. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  4. The challenging image-guided abdominal mass biopsy: established and emerging techniques 'if you can see it, you can biopsy it'.

    Science.gov (United States)

    Sainani, Nisha I; Arellano, Ronald S; Shyn, Paul B; Gervais, Debra A; Mueller, Peter R; Silverman, Stuart G

    2013-08-01

    Image-guided percutaneous biopsy of abdominal masses is among the most commonly performed procedures in interventional radiology. While most abdominal masses are readily amenable to percutaneous biopsy, some may be technically challenging for a number of reasons. Low lesion conspicuity, small size, overlying or intervening structures, motion, such as that due to respiration, are some of the factors that can influence the ability and ultimately the success of an abdominal biopsy. Various techniques or technologies, such as choice of imaging modality, use of intravenous contrast and anatomic landmarks, patient positioning, organ displacement or trans-organ approach, angling CT gantry, triangulation method, real-time guidance with CT fluoroscopy or ultrasound, sedation or breath-hold, pre-procedural image fusion, electromagnetic tracking, and others, when used singularly or in combination, can overcome these challenges to facilitate needle placement in abdominal masses that otherwise would be considered not amenable to percutaneous biopsy. Familiarity and awareness of these techniques allows the interventional radiologist to expand the use of percutaneous biopsy in clinical practice, and help choose the most appropriate technique for a particular patient.

  5. Accuracy of pre-operative hysteroscopic guided biopsy for predicting final pathology in uterine malignancies.

    Science.gov (United States)

    Martinelli, Fabio; Ditto, Antonino; Bogani, Giorgio; Signorelli, Mauro; Chiappa, Valentina; Lorusso, Domenica; Haeusler, Edward; Raspagliesi, Francesco

    2017-07-01

    To evaluate concordance (C) between pre-operative hysteroscopic-directed sampling and final pathology in uterine cancers. A retrospective cross-sectional evaluation of prospectively collected data of women who underwent hysterectomy for uterine malignancies and a previous hysteroscopic-guided biopsy was performed. Diagnostic concordance between pre-operative (hysteroscopic biopsy) and postoperative (uterine specimen) histology was evaluated. In endometrioid-endometrial cancers cases Kappa (k) statistics was applied to evaluate agreement for grading (G) between the preoperative and final pathology. A total 101 hysterectomies for uterine malignancies were evaluated. There were 23 non-endometrioid cancers: 7 serous (C:5/7, 71.4%); 10 carcinosarcomas (C:7/10, 70%, remaining 3 cases only epithelial component diagnosed); 3 clear cell (C:3/3, 100%); 3 sarcomas (C:3/3, 100%). In 78 cases an endometrioid endometrial cancer was found. In 63 cases there was a histological C (63/78, 80.8%) between hysteroscopic-guided biopsy and final pathology, while in 15 cases (19.2%) only hyperplasia (with/without atypia) was found preoperatively. Overall accuracy to detect endometrial cancer was 80.2%. In 50 out of 63 endometrial cancers (79.4%) grading was concordant. The overall level of agreement between preoperative and postoperative grading was "substantial" according to Kappa (k) statistics (k 0.64; 95% CI: 0.449-0.83; p < 0.001), as well as for G1 (0.679; 95% CI: 0.432-0.926; p < 0.001) and G3 (0.774; 94% CI: 0.534-1; p < 0.001), while for G2 (0.531; 95% CI: 0.286-0.777; p < 0.001) it was moderate. In our series we found an 80% C between pre-operative hysteroscopic-guided biopsy and final pathology, in uterine malignancies. Moreover, hysteroscopic biopsy accurately predicted endometrial cancer in 80% of cases and "substantially" predicted histological grading. Hysteroscopic-guided uterine sampling could be a useful tool to tailor treatment in patients with uterine

  6. The clinical application of percutaneous auto-biopsy of small lung nodular under CT-Guided

    International Nuclear Information System (INIS)

    Zhou Yuanmin; Ye Genxin; Zhang Chenghui; Wang Yu; Chen Wei

    2008-01-01

    Objective: To evaluated the clinical value of technology of petcutaneous auto-biopsy of small lung nodular under CT- Guide. Methods: 44 cases of small single lung nodular were underwent biopsy with 20G auto-biopsy needle under CT guidance. All cases underwent pathological diagnosis. Results: All 44 cases were punctured successfully. 41 cases were succeeded in first puncturation. The success ratio was 93.02%. Other 3 cases needed second puncturation. 39 of 44 cases pathological diagnosis were malignant. Only 1 case could not be diagnosed. 6 patients had lightly pneumatothorax after biopsy. 10 cases had mild pneumonorrhagia after biopsy. 2 of them had haemptysis. All cases had no complication such as infection, needle track implantation. Conclusion: The technology of CT Guidance auto-biopsy of small lung nodular is safe and effective; it has extreme diagnostic ratio and less complication. (authors)

  7. Computational adaptive optics for broadband interferometric tomography of tissues and cells

    Science.gov (United States)

    Adie, Steven G.; Mulligan, Jeffrey A.

    2016-03-01

    Adaptive optics (AO) can shape aberrated optical wavefronts to physically restore the constructive interference needed for high-resolution imaging. With access to the complex optical field, however, many functions of optical hardware can be achieved computationally, including focusing and the compensation of optical aberrations to restore the constructive interference required for diffraction-limited imaging performance. Holography, which employs interferometric detection of the complex optical field, was developed based on this connection between hardware and computational image formation, although this link has only recently been exploited for 3D tomographic imaging in scattering biological tissues. This talk will present the underlying imaging science behind computational image formation with optical coherence tomography (OCT) -- a beam-scanned version of broadband digital holography. Analogous to hardware AO (HAO), we demonstrate computational adaptive optics (CAO) and optimization of the computed pupil correction in 'sensorless mode' (Zernike polynomial corrections with feedback from image metrics) or with the use of 'guide-stars' in the sample. We discuss the concept of an 'isotomic volume' as the volumetric extension of the 'isoplanatic patch' introduced in astronomical AO. Recent CAO results and ongoing work is highlighted to point to the potential biomedical impact of computed broadband interferometric tomography. We also discuss the advantages and disadvantages of HAO vs. CAO for the effective shaping of optical wavefronts, and highlight opportunities for hybrid approaches that synergistically combine the unique advantages of hardware and computational methods for rapid volumetric tomography with cellular resolution.

  8. Listening to music during transrectal ultrasound-guided prostate biopsy decreases anxiety, pain and dissatisfaction in patients: a pilot randomized controlled trial.

    Science.gov (United States)

    Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An

    2015-01-01

    To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel

  9. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  10. The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach

    Directory of Open Access Journals (Sweden)

    Kevin Krughoff

    2013-01-01

    Full Text Available Background. Prostate cancer is often understaged following 12-core transrectal ultrasound- (TRUS- guided biopsies. Our goal is to understand where cancers are typically missed by this method. Methods. Transperineal 3-dimensional mapping biopsy (3DMB provides a more accurate depiction of disease status than transrectal ultrasound- (TRUS- guided biopsy. We compared 3DMB findings in men with prior TRUS-guided biopsies to determine grade and location of missed cancer. Results were evaluated for 161 men with low-risk organ confined prostate cancer. Results. The number of cancer-positive biopsy zones per patient with TRUS was 1.38 ± 1.21 compared to 3.33 ± 4.06 with 3DMB, with most newly discovered cancers originating from the middle lobe and apex. Approximately half of all newly discovered cancerous zones resulted from anterior 3DMB sampling. Gleason upgrade was recognized in 56 patients using 3DMB. When both biopsy methods found positive cores in a given zone, Gleason upgrades occurred most frequently in the middle left and right zones. TRUS cancer-positive zones not confirmed by 3DMB were most often the basal zones. Conclusion. Most cancer upgrades and cancers missed from TRUS biopsy originated in the middle left zone of the prostate, specifically in anterior regions. Anterior sampling may lead to more accurate diagnosis and appropriate followup.

  11. Risk of disseminated intravascular coagulation in patients undergoing US-guided transperineal prostatic biopsy

    International Nuclear Information System (INIS)

    Stella, M.S.; Comparato, D.; Camici, M.; Evangelisti, L.; Gaudio, V.; De Negri, F.; Talarico, L.; Giusti, C.; Morelli, G.

    1991-01-01

    Disseminated intravascular coagulation (DIC) is a severe life-threatening acute bleeding disorder. Traumatized tissues, tumors, necrotic tissues, or bacterial endotoxines release similar material in the blood to the tissutal factors activating the coagulation cascade. This preliminary study was aimed at verifying the risk of DIV in patients undergoing US-guided transperineal prostatic biopsy with Chiba and Tru-Cut needles. To evaluate the activation degree of coagulation factors in the circulation, the authors measured the concentrations of urinary fibrin degradation products in 10 patients undergoing US-guided transperineal prostatic biopsy, both before and after biopsy, every second hour, for 24 hours. Every tube of urine sample contained soya bean trypsin inhibitor and bovine thrombin to prevent any further fibrin degradation during incubation period for the possible presence of blood in urine samples. The results showed that 7/10 patients had marked increase in urinary fibrin degradation product levels (up to 800 XXXX%), with a 3-phase trend: early peak after 2-6 hours, middle peak after 6-14 hours, and late peak after 18-24 hours, which proved the activation of the coagulation cascade

  12. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    Science.gov (United States)

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  13. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.

    Science.gov (United States)

    Ersoy, Ahmet Ersan; Turkyilmaz, Ilser; Ozan, Oguz; McGlumphy, Edwin A

    2008-08-01

    Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees+/-2.36 degrees, whereas the mean linear deviation was 1.22+/-0.85 mm at the implant neck and 1.51+/-1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees+/-0.36 degrees, 1.04+/-0.56 mm, and 1.57+/-0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees+/-0.31 degrees, 1.42+/-1.05 mm, and 1.44+/-1.03 mm, respectively. SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.

  14. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  15. Navigated MRI-guided liver biopsies in a closed-bore scanner: experience in 52 patients.

    Science.gov (United States)

    Moche, Michael; Heinig, Susann; Garnov, Nikita; Fuchs, Jochen; Petersen, Tim-Ole; Seider, Daniel; Brandmaier, Philipp; Kahn, Thomas; Busse, Harald

    2016-08-01

    To evaluate clinical effectiveness and diagnostic efficiency of a navigation device for MR-guided biopsies of focal liver lesions in a closed-bore scanner. In 52 patients, 55 biopsies were performed. An add-on MR navigation system with optical instrument tracking was used for image guidance and biopsy device insertion outside the bore. Fast control imaging allowed visualization of the true needle position at any time. The biopsy workflow and procedure duration were recorded. Histological analysis and clinical course/outcome were used to calculate sensitivity, specificity and diagnostic accuracy. Fifty-four of 55 liver biopsies were performed successfully with the system. No major and four minor complications occurred. Mean tumour size was 23 ± 14 mm and the skin-to-target length ranged from 22 to 177 mm. In 39 cases, access path was double oblique. Sensitivity, specificity and diagnostic accuracy were 88 %, 100 % and 92 %, respectively. The mean procedure time was 51 ± 12 min, whereas the puncture itself lasted 16 ± 6 min. On average, four control scans were taken. Using this navigation device, biopsies of poorly visible and difficult accessible liver lesions could be performed safely and reliably in a closed-bore MRI scanner. The system can be easily implemented in clinical routine workflow. • Targeted liver biopsies could be reliably performed in a closed-bore MRI. • The navigation system allows for image guidance outside of the scanner bore. • Assisted MRI-guided biopsies are helpful for focal lesions with a difficult access. • Successful integration of the method in clinical workflow was shown. • Subsequent system installation in an existing MRI environment is feasible.

  16. MRI screening-detected breast lesions in high-risk young women: the value of targeted second-look ultrasound and imaging-guided biopsy.

    Science.gov (United States)

    Peter, P; Dhillon, R; Bose, S; Bourke, A

    2016-10-01

    To analyse the value of targeted second-look ultrasound and imaging-guided biopsy in high-risk young women eligible for screening magnetic resonance imaging (MRI) in a tertiary referral centre in Perth, Western Australia. A retrospective analysis of eligible high-risk young women who underwent screening breast MRI and targeted second-look ultrasound between June 2012 and June 2014 was performed with review of data. Over a 2-year period, 139 women underwent high-risk screening MRI. Of these, 30 women (with a total of 45 lesions) were recalled for targeted second-look ultrasound. Thirty-four MRI-detected lesions were identified on targeted ultrasound with 19 of them proceeding to ultrasound-guided biopsy, while the remaining 15 lesions were considered benign on ultrasound, were not biopsied, and were stable on follow-up imaging 12 months later. One lesion proceeded to an MRI-guided biopsy to confirm a benign result. Of the 11 lesions not seen on ultrasound, nine underwent MRI biopsy, one proceeded directly to hook wire localisation and excision, and one did not return for biopsy and was lost to follow-up. The overall biopsy rate was 14.4%. The cancer detection rate was 1.4%. The results of this study indicate that targeted second-look ultrasound and ultrasound-guided biopsy is a cost-effective and time-efficient approach for MRI-detected lesions in young women at high risk of developing breast cancer. MRI-guided biopsy should be considered for ultrasonographically occult suspicious lesions as there is a low, but definite, risk of cancer. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  17. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  18. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  19. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  20. Clinical Impact of Emphysema Evaluated by High-Resolution Computed Tomography on Idiopathic Pulmonary Fibrosis Diagnosed by Surgical Lung Biopsy.

    Science.gov (United States)

    Kohashi, Yasuo; Arai, Toru; Sugimoto, Chikatoshi; Tachibana, Kazunobu; Akira, Masanori; Kitaichi, Masanori; Hayashi, Seiji; Inoue, Yoshikazu

    2016-01-01

    The prognosis of combined cases of pulmonary fibrosis and emphysema is unresolved partially because radiological differentiation between usual interstitial pneumonia and nonspecific interstitial pneumonia is difficult in coexisting emphysema cases. The purpose of this study was to clarify the clinical impact of emphysema on the survival of patients with idiopathic pulmonary fibrosis (IPF). One hundred and seven patients with interstitial lung diseases were diagnosed by surgical lung biopsies between 2006 and 2012, and 47 patients were diagnosed with IPF through multidisciplinary discussion. Emphysema on high-resolution computed tomography scans was evaluated semiquantitatively by visual scoring. Eight out of the 47 IPF patients showed a higher emphysema score (>3) and were diagnosed to have IPF-emphysema. The median survival time of patients with IPF-emphysema (1,734 days) from the initial diagnosis was significantly shorter than that of patients with IPF alone (2,229 days) by Kaplan-Meier analysis (p = 0.007, log-rank test). Univariate Cox proportional hazard regression analyses revealed that a higher total emphysema score (>3.0) was a significantly poor prognostic factor in addition to Krebs von den Lungen-6, surfactant protein-D, arterial oxygen tension, percent forced vital capacity, and percent diffusing capacity of carbon monoxide (%DLCO). Multivariate Cox proportional hazard regression analyses with the stepwise method showed that higher total emphysema score (>3) and %DLCO were significantly poor prognostic factors. The prognosis of IPF-emphysema was significantly worse than that of IPF alone. © 2016 S. Karger AG, Basel.

  1. MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, J., E-mail: juliengarnon@gmail.com [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Caudrelier J, J., E-mail: caudjean@yahoo.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Erceg, G., E-mail: erceggorislav@yahoo.com; Breton, E., E-mail: ebreton@unistra.fr [ICube, University of Strasbourg, CNRS (France); Tsoumakidou, G., E-mail: gtsoumakidou@yahoo.com; Rao, P., E-mail: pramodrao@me.com; Gangi, A., E-mail: gangi@unistra.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France)

    2016-05-15

    ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

  2. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  3. Usefulness of CT-guided automatic needle biopsy of solitary pulmonary nodule smaller than 15 mm

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lim, Yeong Su

    2004-01-01

    To evaluate the usefulness of the CT-guided percutaneous lung biopsy for the solitary pulmonary nodules smaller than 15 mm in diameter. Between April 2002 and May 2003, we evaluated twenty-five patients (11 men, 14 women, mean ages: 52.5 years) who had solitary pulmonary nodules, which we could not discriminate as being benign or malignant on the CT findings. All the subjects had CT-guided percutaenous cutting needle biopsy (PCNB) performed on them at our institution. A definitive diagnosis of benignity or malignancy was established to retrospectively analyze the patient's records. We evaluated the accuracy, sensitivity, specificity and complications of PCNB for the definitive diagnosis of benignity or malignancy. The sensitivity and specificity of PCNB were determined using the Chi-square test, and the correlations with pneumothorax and emphysema after biopsy were analyzed using Spearman's rank correlation coefficient. In two nodules of the twenty-five nodules, no definitive diagnosis could be established. Of the remaining twenty-three nodules, 7 (30.4%) were malignant and 16 (69.6%) were benign. Twenty (87%) of the twenty-three definitively diagnosed nodules were correctly diagnosed with PCNB. Of the twenty nodules, 6 (30%) were malignant and 14 (70%) were benign. The sensitivity and specificity of the malignant nodules were 85.7% (6/7) and 100% (16/16), respectively. The sensitivity and specificity of the benign nodules were 87.5% (14/16) and 85.7% (6/7), respectively. Post-biopsy complication occurred in nine patients (36%): Hemoptysis (n=4, 16%) and pneumothorax (n=5, 20%). However, there was not a statistical significance between pneumothorax and emphysema after biopsy (r=0.3, p=0.15). When CT-guided percutaneous lung biopsy of the solitary pulmonary nodules smaller than 15 mm in diameter was performed without an on-site cytopathologist, we know that PCNB can yield high diagnostic accuracy and very few complications

  4. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  5. Comparison of needles size in pediatric renal biopsy with sono-guided percutaneous-automated gun technique

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Park, Jin Yong

    1997-01-01

    To compare the efficacy of a 20-gauge and an 18-gauge needle in sono-guided percutaneous automated gun biopsy for establishing the specific diagnosis of renal parenchymal disease in pediatric kidneys. In 60 pediatric patients with renal parenchymal diseases, percutaneous sono-guided gun biopsy was performed by an experienced radiologist. In two groups of 30 patients, regardless of their age, two needle passes were performed, using alternately an 18-gauge or a 20-gauge biopsy needle. The core of renal tissue thus obtained was examined with light, immunofluorescent or electron microscopy by the renal pathologist. The mean number of intact glomeruli of whole tissue core per biopsy, as seen on the light microscopy, and post-bioptic complications were compared between the two different needle size groups. The number (mean±1 standard deviation) of glomeruli obtained per biopsy was 17±8 in the 18-gauge needle group, and 14±5 in the 20-gauge group. Between two groups, there was no major post-bioptic complication requiring specific treatment, nor a statistically significant difference in the frequency of minor complications. Even though more glomeruli were obtained with an 18-gauge needle, the number obtained with a 20-gauge needle also permitted adequate pathologic examination. Both an 18-gauge and a 20-gauge needle may thus be suitable for renal biopsy in pediatric patients

  6. Electromagnetic Navigational Bronchoscopy versus CT-guided Percutaneous Sampling of Peripheral Indeterminate Pulmonary Nodules: A Cohort Study.

    Science.gov (United States)

    Bhatt, Kavita M; Tandon, Yasmeen K; Graham, Ruffin; Lau, Charles T; Lempel, Jason K; Azok, Joseph T; Mazzone, Peter J; Schneider, Erika; Obuchowski, Nancy A; Bolen, Michael A

    2018-03-01

    Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review. Lung nodule characteristics were reviewed through direct image analysis. Molecular marker studies and pathologic analyses from surgical excision were reviewed when available. Multiple-variable logistic regression models were built to compare the diagnostic yield and complication rates for each method and for different patient and disease characteristics. Results CT-guided sampling was more likely to be diagnostic than ENB-guided biopsy (86.0% [129 of 150] vs 66.0% [99 of 150], respectively), and this difference remained significant even after adjustments were made for patient and nodule characteristics (P guided sampling (P guided sampling, 88.9% [32 of 36]; CT-guided sampling, 82.0% [41 of 50]). The two groups had similar rates of major complications (symptomatic hemorrhage, P > .999; pneumothorax requiring chest tube and/or admission, P = .417). Conclusion CT-guided transthoracic biopsy provided higher diagnostic yield in the assessment of peripheral pulmonary nodules than navigational bronchoscopy with a similar rate of clinically relevant complications. © RSNA, 2017 Online supplemental material is available for this article.

  7. The Positive Outcome of MRI-Guided Vacuum Assisted Core Needle Breast Biopsies Is Not Influenced by a Prior Negative Targeted Second-Look Ultrasound.

    Science.gov (United States)

    Ferré, Romuald; AlSharif, Shaza; Aldis, Ann; Mesurolle, Benoît

    2017-11-01

    The study sought to investigate the outcome of breast magnetic resonance-guided biopsies as a function of the indication for magnetic resonance imaging (MRI), the MRI features of the lesions, and the performance or not of a targeted second-look ultrasound (SLUS) prior breast MRI-guided biopsy. We identified 158 women with MRI-detected breast lesions scheduled for MRI-guided biopsy (2007-2013). Patient demographics, performance of targeted SLUS, imaging characteristics, and subsequent pathology results were reviewed. Three biopsies were deferred, and 155 lesions were biopsied under MRI guidance (155 women; median age 55.14 years; range 27-80 years). Ninety-eight women underwent a SLUS prior to the MRI-guided biopsy (63%). Of the 155 biopsied lesions, 23 (15%) were malignant, 106 (68%) were benign, and 26 (17%) were high risk. Four of 15 surgically excised high-risk lesions were upgraded to malignancy (27%). Most of the biopsied lesions corresponded to non-mass-like enhancement (81%, 126 of 155) and most of the biopsies (52%, 81 of 155) were performed in a screening context. No demographic or MRI features were associated with malignancy. No differences were noted between the 2 subgroups (prior SLUS vs no prior SLUS) except for the presence of a synchronous carcinoma associated with a likelihood of targeted SLUS before MRI-guided biopsy (P = .001). A negative SLUS does not influence the pathology outcome of a suspicious lesion biopsied under MR guidance. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  8. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    Science.gov (United States)

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason  7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  9. Computed tomography in the evaluation of the suspected carcinomatous prostate

    International Nuclear Information System (INIS)

    Price, J.M.; Davidson, A.J.

    1979-01-01

    Twenty-six patients with physical findings suspicious for prostatic cancer were examined by contrast-enhanced computed tomography (CT) of the prostate region prior to prostatic biopsy or resection. Twelve had benign hypertrophy and/or prostatitis and fourteen had adenocarcinoma. Prostatic contour, density, seminal vesicle 'angle,' extraprostatic soft tissue 'mass,' and the pelvic fat planes were evaluated. A nodular prostatic contour was found only in patients with adenocarcinoma of the prostate, indicating a role for CT in the diagnosis of this disease. Two patients with benign prostatic disease had extraprostatic soft tissue 'masses' identical to those seen in six patients with adenocarcinoma of the prostate, suggesting limited usefulness of CT in staging patients with known tumor. (orig.) [de

  10. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  11. Computed Tomography Number Changes Observed During Computed Tomography–Guided Radiation Therapy for Head and Neck Cancer

    International Nuclear Information System (INIS)

    Feng, Mei; Yang, Cungeng; Chen, Xiaojian; Xu, Shouping; Moraru, Ion; Lang, Jinyi; Schultz, Christopher; Li, X. Allen

    2015-01-01

    Purpose: To investigate CT number (CTN) changes in gross tumor volume (GTV) and organ at risk (OAR) according to daily diagnostic-quality CT acquired during CT-guided intensity modulated radiation therapy for head and neck cancer (HNC) patients. Methods and Materials: Computed tomography scans acquired using a CT-on-rails during daily CT-guided intensity modulated radiation therapy for 15 patients with stage II to IVa squamous cell carcinoma of the head and neck were analyzed. The GTV, parotid glands, spinal cord, and nonspecified tissue were generated on each selected daily CT. The changes in CTN distributions and the mean and mode values were collected. Pearson analysis was used to assess the correlation between the CTN change, organ volume reduction, and delivered radiation dose. Results: Volume and CTN changes for GTV and parotid glands can be observed during radiation therapy delivery for HNC. The mean (±SD) CTNs in GTV and ipsi- and contralateral parotid glands were reduced by 6 ± 10, 8 ± 7, and 11 ± 10 Hounsfield units, respectively, for all patients studied. The mean CTN changes in both spinal cord and nonspecified tissue were almost invisible (<2 Hounsfield units). For 2 patients studied, the absolute mean CTN changes in GTV and parotid glands were strongly correlated with the dose delivered (P<.001 and P<.05, respectively). For the correlation between CTN reductions and delivered isodose bins for parotid glands, the Pearson coefficient varied from −0.98 (P<.001) in regions with low-dose bins to 0.96 (P<.001) in high-dose bins and were patient specific. Conclusions: The CTN can be reduced in tumor and parotid glands during the course of radiation therapy for HNC. There was a fair correlation between CTN reduction and radiation doses for a subset of patients, whereas the correlation between CTN reductions and volume reductions in GTV and parotid glands were weak. More studies are needed to understand the mechanism for the radiation-induced CTN changes

  12. Usefulness of CT-guided trans-bronchial needle aspiration biopsy for mediastinal lymph nodes

    International Nuclear Information System (INIS)

    Cui Bing; Rong Fu

    2001-01-01

    Objective: To determine the nature of enlarged mediastinal lymph nodes, the study of CT-guided trans-bronchial needle aspiration biopsy (CT-TBNA) was conducted. Methods: According to classification and locating standard of mediastinal lymph nodes, CT-TBNA was performed in 158 mediastinal lymph nodes of 73 patients, including 54 primary lung cancer with enlarged mediastinal lymph nodes, 5 malignant lymphoma, 3 mediastinal abscess and 11 mediastinal inflammatory adenopathy. Results: CT confirmed that the needles were inside all 158 lymph nodes. Adequate aspirates for histologic and/or cytologic diagnosis were obtained in 136 of 158(86%) lymph node biopsies. No serious complications occurred. Conclusion: Locating standard of CT-guided TBNA was reliable. Puncture was safe and cost-effective. CT-TBNA was important for ascertaining the nature of mediastinal adenopathy and staging of neoplasms

  13. The effect of rectal Foley catheterization on rectal bleeding rates after transrectal ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Kilciler, Mete; Erdemir, Fikret; Demir, Erkan; Güven, Oğuz; Avci, Ali

    2008-09-01

    To assess whether Foley catheterization of the rectum after transrectal ultrasound (TRUS)-guided prostate biopsy decreases complication rates. Between June 2000 and September 2006, 275 consecutive patients were evaluated after undergoing TRUS-guided prostate biopsy. All procedures were performed on an outpatient basis. Patients were divided into two groups. In the first group (n = 134), a Foley catheter was inserted into the rectum and inflated to 50 cm(3) after TRUS-guided biopsy. In the second group (n = 141), catheterization was performed without balloon placement. Rectal bleeding, hematuria, hematospermia, infection, and acute urinary retention rates were compared between groups. The mean ages of the patients were 63.3 years +/- 5.6 and 62.1 years +/- 7.2 years in the Foley catheter group and control group, respectively (P = .112). Hematuria, hematospermia, infection, and rectal bleeding occurred in 31 (23.1%), 30 (22.4), nine (6.7%), and two patients (1.5%), respectively, in the Foley catheter group; and in 36 (25.5%), 36 (25.5%), 11 (7.8%), and 25 patients (17.7%), respectively, in the control group. The incidences of infection, hematuria, and hematospermia were not significantly different between groups (P > .05). In contrast, the rectal bleeding rate was significantly lower in the Foley catheter group (1.5%) than in the control group (17.7%; P = .001). Although it has no effect on other complications, TRUS-guided prostate biopsy with rectal Foley catheterization is a useful, practical method to decrease or prevent rectal bleeding.

  14. Biopsy guided by real-time sonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C.; Grossjohann, Hanne Sønder; Nielsen, Kristina Rue

    2008-01-01

    OBJECTIVE: The purpose of our study was to test the accuracy of sonographically guided biopsies in a phantom of structures not visible on sonography but shown on MRI by using commercially available sonography systems with image fusion software. MATERIALS AND METHODS: A previously recorded MRI...

  15. Stereotactic biopsy aided by a computer graphics workstation: experience with 200 consecutive cases.

    Science.gov (United States)

    Ulm, A J; Bova, F J; Friedman, W A

    2001-12-01

    The advent of modern computer technology has made it possible to examine not just the target point, but the entire trajectory in planning for stereotactic biopsies. Two hundred consecutive biopsies were performed by one surgeon, utilizing a computer graphics workstation. The target point, entry point, and complete trajectory were carefully scrutinized and adjusted to minimize potential complications. Pathologically abnormal tissue was obtained in 197 cases (98.5%). There was no mortality in this series. Symptomatic hemorrhages occurred in 4 cases (2%). Computer graphics workstations facilitate safe and effective biopsies in virtually any brain area.

  16. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  17. MRI-only lesions: application of diffusion-weighted imaging obviates unnecessary MR-guided breast biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio; Pinker-Domenig, Katja; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna (AKH), General Hospital Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria); Rudas, Margaretha [Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)

    2014-06-15

    To assess if the application of diffusion-weighted imaging (DWI) obviates unnecessary MR-guided biopsies in suspicious breast lesions visible only on contrast-enhanced MRI (CE-MRI). This institutional review board (IRB)-approved, retrospective, single-centre study included 101 patients (mean age, 49.5; SD 13.9 years) who underwent additional DWI at 1.5 T prior to MRI-guided biopsy of 104 lesions classified as suspicious for malignancy and visible on CE-MRI only. An experienced radiologist, blinded to histopathologic and follow-up results, measured apparent diffusion coefficient (ADC) values obtained from DWI. Diagnostic accuracy was investigated using receiver operating characteristics (ROC) analysis. Histopathology revealed 20 malignant and 84 benign lesions. Lesions were masses in 61 (15 malignant, 24.6 %) and non-masses in 43 cases (five malignant, 11.6 %). Mean ADC values were 1.53 ± 0.38 x 10{sup -3} mm{sup 2}/s in benign lesions and 1.06 ± 0.27 x 10{sup -3} mm{sup 2}/s in malignant lesions. ROC analysis revealed exclusively benign lesions if ADC values were greater than 1.58 x 10{sup -3} mm{sup 2}/s. As a consequence, 29 false-positive biopsies (34.5 %) could have been avoided without any false-negative findings. Both in mass and in non-mass lesions, rule-in and rule-out criteria were identified using flexible ADC thresholds based on ROC analysis. Additional application of DWI in breast lesions visible only on MRI can avoid false-positive, MR-guided biopsies. Thus, DWI should be an integral part of breast MRI protocols. (orig.)

  18. MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio; Schernthaner, Melanie; Pinker, Katja; Kapetas, Panagiotis; Bernathova, Maria; Polanec, Stephan H.; Bickel, Hubert; Wengert, Georg J.; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna (AKH), Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria); Rudas, Margaretha [Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)

    2016-11-15

    The purpose of this study was to compare three different biopsy devices on false-negative and underestimation rates in MR-guided, vacuum-assisted breast biopsy (VABB) of MRI-only lesions. This retrospective, single-center study was IRB-approved. Informed consent was waived. 467 consecutive patients underwent 487 MR-guided VABB using three different 8-10-gauge-VABB devices (Atec-9-gauge,A; Mammotome-8-gauge,M; Vacora-10-gauge,V). VABB data (lesion-type, size, biopsy device, histopathology) were compared to final diagnosis (surgery, n = 210 and follow-up, n = 277). Chi-square, and Kruskal-Wallis tests were applied. P values < 0.05 were considered significant. Final diagnosis was malignant in 104 (21.4 %), high risk in 64 (13.1 %) and benign in 319 (65.5 %) cases. Eleven of 328 (3.4 %) benign-rated lesions were false-negative (1/95, 1.1 %, A; 2/73, 2.7 %, M; 8/160 5.0 % V; P = 0.095). Eleven high-risk (11/77, 14.3 %) lesions proved to be malignant (3/26, 11.5 % A; 4/12, 33.3 % M; 4/39, 10.3 % V; P = 0.228). Five of 34 (14.7 %) DCIS were upgraded to invasive cancer (2/15, 13.3 %, A; 1/6, 16.6 % M; 2/13, 15.3 %, V; P = 0.977). Lesion size (P = 0.05) and type (mass vs. non-mass, P = 0.107) did not differ significantly. MR-guided VABB is an accurate method for diagnosis of MRI-only lesions. No significant differences on false-negative and underestimation rates were observed between three different biopsy devices. (orig.)

  19. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-aided implant placement. Part II: reliability of mucosa-supported stereolithographic guides.

    Science.gov (United States)

    Arisan, Volkan; Karabuda, Zihni Cüneyt; Pişkin, Bülent; Özdemir, Tayfun

    2013-12-01

    Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study. Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05). Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively). Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners. © 2012 Wiley Periodicals, Inc.

  20. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  1. Transrectal ultrasound-guided biopsy sepsis and the rise in carbapenem antibiotic use.

    Science.gov (United States)

    Leahy, Olivia R; O'Reilly, Mary; Dyer, David R; Phillips, David; Grummet, Jeremy P

    2015-12-01

    This study sought to determine the number of hospital admissions for sepsis following transrectal ultrasound-guided (TRUS) biopsy, and the rate of both prophylactic and therapeutic use of carbapenem antibiotics for TRUS biopsy, at a single institution. A retrospective review of prospectively collected data from the medical records electronic database of Cabrini Health, a private metropolitan hospital, was queried for coding of admissions under any admitting urologist for sepsis and prostate-related infections from 2009 to 2012. Records were examined for whether a TRUS biopsy had been performed within 14 days prior and if a therapeutic carbapenem was required. The database also queried the use of carbapenems as prophylaxis in patients undergoing TRUS biopsy. Of the 63 admissions for TRUS biopsy sepsis, multi-drug-resistant organisms were isolated from 26 (41%). Twenty-three admissions were from the 1937 patients who underwent a TRUS biopsy at Cabrini (a sepsis rate of 1.2%) and 40 were following TRUS biopsies at other centres. Thirty-seven (58.7%) patients received therapeutic carbapenems either empirically, or after culture results. Of the 1937 Cabrini TRUS biopsy patients, 154 (8%) were given a carbapenem as prophylaxis, with a rapid increase in prophylactic use over the 4 years studied from 0.25% to 13%. This study did not show evidence of an increasing rate of hospital admissions for TRUS biopsy sepsis at this institution. However, there was a dramatic uptake in prophylactic administration of carbapenems. Increasing carbapenem use may contribute to development of carbapenem-resistant bacteria. Alternative methods of prostate biopsy that avoid sepsis should be considered. © 2014 Royal Australasian College of Surgeons.

  2. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  4. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years.

    Science.gov (United States)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong

    2017-08-01

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. • CT-guided core needle biopsy is an accurate technique for diagnosing mediastinal nodes. • The rates of complications are similar to those for pulmonary lesion biopsy. • Pneumothorax risk factors include distance from pleura to target lesion and number of visceral pleura. • Distance from pleura to target lesion is the risk factor for hemoptysis. • CT-guided core needle biopsy is an important diagnostic method for mediastinal nodes.

  5. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  6. Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

    DEFF Research Database (Denmark)

    Larsen, M H; Fristrup, C W; Detlefsen, S

    2018-01-01

    Background and study aim : Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions...

  7. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases

    International Nuclear Information System (INIS)

    Puri, A.; Shingade, V.U.; Agarwal, M.G.; Anchan, C.; Juvekar, S.; Desai, S.; Jambhekar, N.A.

    2006-01-01

    Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst

  8. Effectiveness of stress management in patients undergoing transrectal ultrasound-guided biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Chiu LP

    2016-02-01

    Full Text Available Li-Pin Chiu,1,2 Heng-Hsin Tung,3 Kuan-Chia Lin,3 Yu-Wei Lai,1,4 Yi-Chun Chiu,1,4 Saint Shiou-Sheng Chen,1,4 Allen W Chiu1,4 1Division of Urology, Taipei City Hospital, 2University of Taipei, General Education Center, 3School of Nursing, Department of Care Management, National Taipei University of Nursing and Health Science, 4Department of Urology, National Yang-Ming University School of Medicine, Taipei, Taiwan, Republic of China Background: To assess the utilization of stress management in relieving anxiety and pain among patients who undergo transrectal ultrasound (TRUS-guided biopsy of the prostate.  Methods: Eighty-two patients admitted to a community hospital for a TRUS biopsy of the prostate participated in this case-controlled study. They were divided into an experimental group that was provided with stress management and a control group that received only routine nursing care. Stress management included music therapy and one-on-one simulation education. Before and after the TRUS biopsy, the patients’ state-anxiety inventory score, pain visual analogue scale (VAS, respiratory rate, heart rate, and blood pressure were obtained.  Results: There were no differences in baseline and disease characteristics between the two groups. The VAS in both groups increased after the TRUS biopsy, but the difference in pre- and postbiopsy VAS scores was significantly lower in the experimental group (P=0.03. Patients in both groups experienced mild anxiety before and after the biopsy, but those in the experimental group displayed a significantly greater decrease in postbiopsy state-anxiety inventory score compared to the control group (P=0.02.Conclusion: Stress management can alleviate anxiety and pain in patients who received a TRUS biopsy of the prostate under local anesthesia. Keywords: anxiety, pain, stress management, transrectal ultrasound-guided biopsy of the prostate

  9. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  10. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  11. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  12. Protocol for the realization of transrectal prostatic biopsy guided by ultrasound

    International Nuclear Information System (INIS)

    Arce Montero, Jairo

    2013-01-01

    A general protocol is proposed for the realization of the ultrasound-guided prostatic biopsy in patients with positive screening. The screening should be performed taking into account risk antecedents, rectal examination and prostate-specific antigen (PSA) levels in the patients. However, patients that have presented without alteration in the PSA and suspect rectal examination, should be considered for biopsy endorectal with ultrasound guidance even more with positive risk factors. The generalities of prostate cancer are described. The general prostatic anatomy and echographic are reviewed. The echographic technique is analyzed in the exploration endorectal. The echographic findings suspects of prostate cancer are characterized. The different biopsy sampling techniques are described; and based on appropriate knowledge of prostatic echographic anatomy, could increase the effectiveness in the early detection of prostate cancer in patients with positive screening. The complications derived from the process are enumerated. The final recommendations are noted on the protocol described [es

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  14. [Fluoroscopy dose reduction of computed tomography guided chest interventional radiology using real-time iterative reconstruction].

    Science.gov (United States)

    Hasegawa, Hiroaki; Mihara, Yoshiyuki; Ino, Kenji; Sato, Jiro

    2014-11-01

    The purpose of this study was to evaluate the radiation dose reduction to patients and radiologists in computed tomography (CT) guided examinations for the thoracic region using CT fluoroscopy. Image quality evaluation of the real-time filtered back-projection (RT-FBP) images and the real-time adaptive iterative dose reduction (RT-AIDR) images was carried out on noise and artifacts that were considered to affect the CT fluoroscopy. The image standard deviation was improved in the fluoroscopy setting with less than 30 mA on 120 kV. With regard to the evaluation of artifact visibility and the amount generated by the needle attached to the chest phantom, there was no significant difference between the RT-FBP images with 120 kV, 20 mA and the RT-AIDR images with low-dose conditions (greater than 80 kV, 30 mA and less than 120 kV, 20 mA). The results suggest that it is possible to reduce the radiation dose by approximately 34% at the maximum using RT-AIDR while maintaining image quality equivalent to the RT-FBP images with 120 V, 20 mA.

  15. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  16. Pleuroscopic punch biopsy using insulated-tip diathermic knife-2 for the diagnosis of desmoplastic malignant mesothelioma.

    Science.gov (United States)

    Masai, Kyohei; Sasada, Shinji; Izumo, Takehiro; Taniyama, Tomoko; Nakamura, Yukiko; Chavez, Christine; Sakurai, Hiroyuki; Tsuta, Koji; Tsuchida, Takaaki

    2013-10-01

    Desmoplastic malignant mesothelioma (DMM) is a rare subtype of malignant pleural mesothelioma (MPM) and is often difficult to distinguish from pleural fibrosis and reactive mesothelial hyperplasia, especially if the biopsy samples are small. We performed full-thickness pleural biopsy on a lesion suspected to be DMM using an insulated-tip diathermic knife-2 (IT knife-2) during flex-rigid pleuroscopy. IT knife-2 is a novel electrosurgical device for endoscopic submucosal dissection in the early gastrointestinal cancer. It consists of a needle knife with 3 short blades at the distal end attached to an insulated ceramic tip. A 54-year-old man presenting with chest wall mass and thickened pleura, in whom a computed tomography-guided percutaneous needle aspiration had remained negative, underwent flex-rigid pleuroscopy for definitive diagnosis. While applying electric current, we used the IT knife-2 to incise the pleura in a circular shape just above the endothoracic fascia. The incised pleura was removed by forceps and examined pathologically. The microscopic examination was compatible with DMM. We discovered that pleuroscopic punch biopsy using IT knife-2 can diagnose DMM. Use of IT knife-2 during flex-rigid pleuroscopy can obtain sufficient samples from densely thickened pleura, which is difficult to diagnose with small biopsies.

  17. A new method in thoracoscopic inferior mediastinal lymph node biopsy: a case report

    Directory of Open Access Journals (Sweden)

    Sanlı Maruf

    2009-11-01

    Full Text Available Abstract Introduction We performed video-thoracoscopy with a video-mediastinoscope to conduct a mediastinal lymph node biopsy. Here, we discuss the various advantages of the method. Case presentation A 56-year-old Turkish Caucasian man had been complaining of dyspnea on exertion, hacking cough, fever and continuous sweating for one and a half months. Thoracic computed tomography revealed enlarged paratracheal and aorticopulmonary lymph nodes, the largest of which was 1 cm in diameter and reticulo-micronodular interstitial infiltration extending symmetrically to the pleural surfaces in both pulmonary perihilar areas. Computed tomography supported positron emission tomography showed increased fluorodeoxyglucose retention in lymph nodes in both hilar areas (10R and 10L (maximum standardized uptake values 5.6 and 5.7, and in the right lower paratracheal (4R (maximum standardized uptake value 4.1 and right para-esophageal (8 (maximum standardized uptake value 8.9 lymph nodes. Pathological examination of the right lymph node number 8 biopsy using the video-mediastinoscope revealed the presence of granulomatous inflammation. No problems were observed during the postoperative period. Conclusion The use of the video-mediastinoscope for inferior lymph node biopsy in thoracoscopy is an easy, safe and practical method, especially in patients with pleural adhesions.

  18. Clinical application of multi-detector CT-guided percutaneous coaxial biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Jia Ningyang; Liu Shiyuan; Zhang Dianbo; Xiao Xiangsheng; Li Wentao; Li Chenzhou

    2008-01-01

    Objective: To evaluate the clinical application of multi-slice CT-guided percutaneous transthoracic lung coaxial-biopsy for pulmonary lesions. Methods: 152 times of 143 patients were performed with percutaneous transthoracic coaxial biopsy under multiple-slice CT-guidance. Analysis was carried out to investigate the diagnostic accuracy and the relationship between the size of the lesions for coaxial biopsy, together with the complications. Results: The diagnostic accuracy was 94.9% with specificity of 100%, including malignant tumors 116 cases (squamous cell cancer 48 cases, adenocarcinoma 34, small cell undifferentiated carcinoma 6, large cell carcinoma 4, bronchial alveolar carcinoma 8, metastatic carcinoma 16) and 19 cases of benign ones(TB 7 cases, inflammatory pseudotumor 9, hematoma 1, lung abscess 1). The size of lesion had a significant influence on the diagnostic accuracy. Conclusions: Percutaneous transthoracic coaxial lung biopsy is a safety method, possessing a high diagnostic accuracy. (authors)

  19. Computed tomography of juvenile nasopharyngeal angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yoo, Shi Joon; Lee, Yul; Chang, Kee Hyun; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma.

  20. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    Energy Technology Data Exchange (ETDEWEB)

    Nour-Eldin, Nour-Eldin A., E-mail: nour410@hotmail.com [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Cairo University Hospital, Cairo (Egypt); Alsubhi, Mohammed [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Naguib, Nagy N. [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Alexandria University Hospital, Alexandria (Egypt); Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2014-10-15

    Purpose: To evaluate the risk factors involved in the development of pulmonary hemorrhage complicating CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques. Materials and methods: Retrospective study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD: 5.2) from November 2008 to June 2013. Patients were classified according to lung biopsy technique in coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were: lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension or refusal of the procedure. Risk factors for pulmonary hemorrhage complicating lung biopsy were classified into: (a) patient's related risk factors, (b) lesion's related risk factors and (d) technical risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher's exact tests for statistical analysis. p values <0.05 were considered statistically significant. Results: Incidence of pulmonary hemorrhage was 19.6% (65/332) in non-coaxial group and 22.3% (71/318) in coaxial group. The difference in incidence between both groups was statistically insignificant (p = 0.27). Hemoptysis developed in 5.4% (18/332) and in 6.3% (20/318) in the non-coaxial and coaxial groups respectively. Traversing pulmonary vessels in the needle biopsy track was a significant risk factor of the development pulmonary hemorrhage (incidence: 55.4% (36/65, p = 0.0003) in the non-coaxial group and 57.7% (41/71, p = 0.0013) in coaxial group). Other significant risk factors included: lesions of less than 2 cm (p value of 0.01 and 0.02 in non-coaxial and coaxial groups respectively), basal and middle zonal lesions in comparison to upper zonal lung lesions (p = 0.002 and 0.03 in non-coaxial and coaxial groups respectively), increased lesion