WorldWideScience

Sample records for computed tomography-based treatment

  1. [Treatment choice in dacryostenosis based on single-photon emission computed tomography and X-ray computed tomography findings].

    Science.gov (United States)

    At'kova, E L; Yartsev, V D; Tomashevskiy, I O; Krakhovetskiy, N N

    2016-01-01

    To develop surgical indications in dacryostenosis within the vertical portion of lacrimal pathways that would consider findings of single-photon emission computed tomography (SPECT) combined with X-ray computed tomography (CT). A total of 96 patients with isolated vertical-portion dacryostenosis (127 cases) were enrolled. The examination included collecting Munk's scores for epiphora, optical coherence tomography of the lower tear meniscus, lacrimal scintigraphy, and SPECT/CT. Group 1 (40 cases) was composed of patients with lacrimal obstruction on CT, group 2 (87 cases) - of those whose lacrimal pathways proved passable. There were also 3 patients (4 cases) from group 1, whose lacrimal pathways, despite being blocked on CT, were still passable on SPECT. Surgeries performed in group 1 were endoscopic endonasal dacryocystorhinostomy (DCR) (36 cases) and pathways recanalization with bicanalicular intubation and balloon dacryoplasty (DCP) (4 cases). In group 2, all patients (87 cases) underwent recanalization with bicanalicular intubation (supplemented with balloon DCP in 32 cases). Surgical results were evaluated 8-12 months after the treatment. In group 2, particular attention was paid to the concordance in locations of dacryostenosis provided by CT and SPECT scans. Favorable outcomes of endoscopic endonasal DCR were obtained in as many as 32 cases from group 1 (88.9%), while in 4 cases (12.1%) the condition relapsed. Of those patients whose stenosis was not complete on SPECT, 3 cases (75.0%) improved, 1 (25.0%) - relapsed. In group 2, favorable outcomes were obtained in 65 cases (74.7%), relapses were 22 (25.3%). A high concordance in stenosis locations by CT and SPECT was noted in 60 cases of those who improved (92.3%) and 3 cases of those who relapsed (13.6%). The value of information provided by SPECT/CT has proved high in patients with nasolacrimal duct stenosis or obstruction. A combined scan allows to establish causal relationships between anatomical changes

  2. Influence of 18F-fluorodeoxyglucose-positron emission tomography on computed tomography-based radiation treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Everitt, C.; Leong, T.

    2006-01-01

    The addition of positron emission tomography (PET) information to CT-based radiotherapy treatment planning has the potential to improve target volume definition through more accurate localization of the primary tumour and involved regional lymph nodes. This case report describes the first patient enrolled to a prospective study evaluating the effects of coregistered positron emission tomography/CT images on radiotherapy treatment planning for oesophageal cancer. The results show that if combined positron emission tomography/CT is used for radiotherapy treatment planning, there may be alterations to the delineation of tumour volumes when compared to CT alone. For this patient, a geographic miss of tumour would have occurred if CT data alone were used for radiotherapy planning Copyright (2006) Blackwell Publishing Asia Pty Ltd

  3. Nonoperative treatment of splenic trauma: usefulness of computed tomography

    International Nuclear Information System (INIS)

    Resende, Vivian; Tavares Junior, Wilson Campos; Vieira, Jose Nelson Mendes; Drumond, Domingos Andre Fernandes

    2005-01-01

    Objective: to report the results of use of conservative treatment in patients with splenic trauma and to emphasize the usefulness of computed tomography in these cases. Material and method: sixty-nine cases of pediatric patients with blunt abdominal trauma seen from from January 2001 to June 2004 at the level I trauma center were retrospectively studied. Forty-four of these patients were submitted to nonoperative treatment and the clinical follow-up was performed by computerized tomography. All patients had been diagnosed with splenic injury by computerized tomography.Results: the causes of the injuries were motor vehicle accident in 12 (27.2%) patients, bicycle accident in nine (20.4%) patients, and falls in 23 (52.2%) patients. Two (3.7%) patients died from associated injuries. The mean duration of hospital stay was six days. The mean age of the patients was nine years. Conclusion: conservative treatment for blunt splenic trauma is performed with the aim of reducing costs and risks for the patients, and computerized tomography should be routinely used. No posterior complications were observed in this approach. (author)

  4. Positron emission tomography/computed tomography and biomarkers for early treatment response evaluation in metastatic colon cancer

    DEFF Research Database (Denmark)

    Engelmann, Bodil E.; Loft, Annika; Kjær, Andreas

    2014-01-01

    BACKGROUND: Treatment options for metastatic colon cancer (mCC) are widening. We prospectively evaluated serial 2-deoxy-2-[18F]fluoro-d-glucose positron-emission tomography/computed tomography (PET/CT) and measurements of tissue inhibitor of metalloproteinases-1 (TIMP-1), carcinoembryonic antigen...... evaluated by PET/CT before treatment, after one and four treatment series. Morphological and metabolic response was independently assessed according to Response Evaluation Criteria in Solid Tumors and European Organization for Research and Treatment of Cancer PET criteria. Plasma TIMP-1, plasma u...

  5. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  7. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  8. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  9. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  10. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  11. Computed tomography vs. digital radiography assessment for detection of osteolysis in asymptomatic patients with uncemented cups: a proposal for a new classification system based on computer tomography.

    Science.gov (United States)

    Sandgren, Buster; Crafoord, Joakim; Garellick, Göran; Carlsson, Lars; Weidenhielm, Lars; Olivecrona, Henrik

    2013-10-01

    Digital radiographic images in the anterior-posterior and lateral view have been gold standard for evaluation of peri-acetabular osteolysis for patients with an uncemented hip replacement. We compared digital radiographic images and computer tomography in detection of peri-acetabular osteolysis and devised a classification system based on computer tomography. Digital radiographs were compared with computer tomography on 206 hips, with a mean follow up 10 years after surgery. The patients had no clinical signs of osteolysis and none were planned for revision surgery. On digital radiographs, 192 cases had no osteolysis and only 14 cases had osteolysis. When using computer tomography there were 184 cases showing small or large osteolysis and only 22 patients had no osteolysis. A classification system for peri-acetabular osteolysis is proposed based on computer tomography that is easy to use on standard follow up evaluation. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  13. Computed tomography and treatment of chronic temporomandibular joint arthritis in a sheep

    International Nuclear Information System (INIS)

    Warmerdam, E.P.L.; Weeren, P.R. van

    1996-01-01

    Diagnostic imaging and treatment of destructive right temporomandibular joint (TMJ) arthritis in a sheep are discussed. Computed tomography (CT) appears to be an attractive technique for imaging TMJ lesions in sheep. Surgical curettage of a deformed TMJ can result in functional recovery

  14. The application of positron emission tomography/computed tomography in radiation treatment planning: effect on gross target volume definition and treatment management.

    Science.gov (United States)

    Iğdem, S; Alço, G; Ercan, T; Unalan, B; Kara, B; Geceer, G; Akman, C; Zengin, F O; Atilla, S; Okkan, S

    2010-04-01

    To analyse the effect of the use of molecular imaging on gross target volume (GTV) definition and treatment management. Fifty patients with various solid tumours who underwent positron emission tomography (PET)/computed tomography (CT) simulation for radiotherapy planning from 2006 to 2008 were enrolled in this study. First, F-18 fluorodeoxyglucose (FDG)-PET and CT scans of the treatment site in the treatment position and then a whole body scan were carried out with a dedicated PET/CT scanner and fused thereafter. FDG-avid primary tumour and lymph nodes were included into the GTV. A multidisciplinary team defined the target volume, and contouring was carried out by a radiation oncologist using visual methods. To compare the PET/CT-based volumes with CT-based volumes, contours were drawn on CT-only data with the help of site-specific radiologists who were blind to the PET/CT results after a median time of 7 months. In general, our PET/CT volumes were larger than our CT-based volumes. This difference was significant in patients with head and neck cancers. Major changes (> or =25%) in GTV delineation were observed in 44% of patients. In 16% of cases, PET/CT detected incidental second primaries and metastatic disease, changing the treatment strategy from curative to palliative. Integrating functional imaging with FDG-PET/CT into the radiotherapy planning process resulted in major changes in a significant proportion of our patients. An interdisciplinary approach between imaging and radiation oncology departments is essential in defining the target volumes. Copyright 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. In Vivo Treatment Sensitivity Testing With Positron Emission Tomography/Computed Tomography After One Cycle of Chemotherapy for Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Kostakoglu, Lale; Zaucha, Jan Maciej

    2014-01-01

    PURPOSE: Negative [(18)F]fluorodeoxyglucose (FDG) -positron emission tomography (PET)/computed tomography (CT) after two cycles of chemotherapy indicates a favorable prognosis in Hodgkin lymphoma (HL). We hypothesized that the negative predictive value would be even higher in patients responding....... In the absence of precise pretherapeutic predictive markers, PET1 is the best method for response-adapted strategies designed to select patients for less intensive treatment....

  16. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  19. The value of computed tomography (CT) in the treatment of lung cancer

    International Nuclear Information System (INIS)

    Striggaris, K.; Gouliamos, A.; Garmatis, C.; Kaklamanis, N.; Vlahos, L.; Pontifex, G.

    1982-01-01

    The extensive recent literature on computed tomography (CT) includes several reports demonstrating the usefulness of body scanners in radiotherapy treatment planning. This followed earlier experience indicating the potential application of the technique in chest disease. The fast scan-times, possible with newer CT systems, eliminate motion degradation and provide accurate localization of thoracic tumors. This paper reports the authors' experience with CT in treatment planning of 38 patients with bronchogenic carcinoma after pretherapy evaluation by CT. They conclude that the availability of CT-scan data helps to define accurately the target volume and provides the information needed for treatment planning computers in order to estimate the desired dose. (Auth.)

  20. Treatment of a Four-Rooted Maxillary Second Molar Detected with Cone-Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Nahid Mohammadzade Akhlaghi

    2017-08-01

    Full Text Available The significance of clinician’s knowledge about root canal anatomy and its possible variations cannot be overlooked. In some cases, taking advantage of complementary imaging techniques can help achieve a perfect flawless endodontic treatment. This article reports endodontic management of a second maxillary molar that had an uncommon anatomy of the chamber floor. After obtaining a cone-beam computed tomography (CBCT image, the presence of a second palatal root was confirmed. All four roots were treated and patient’s symptoms were resolved.Keywords: Cone-Beam Computed Tomography; Root Canal Therapy; Tooth Root

  1. The outcome of root-canal treatments assessed by cone-beam computed tomography

    NARCIS (Netherlands)

    Liang, Y.H.

    2013-01-01

    In this thesis, in-vivo and ex-vivo methods were utilized to assess the outcome of root canal treatments determined by cone-beam computed tomography (CBCT) and the reliability of the CBCT-findings. CBCT provided useful and reliable information leading to a better understanding of the outcome and

  2. Geometrical differences in target volumes based on 18F-fluorodeoxyglucose positron emission tomography/computed tomography and four-dimensional computed tomography maximum intensity projection images of primary thoracic esophageal cancer.

    Science.gov (United States)

    Guo, Y; Li, J; Wang, W; Zhang, Y; Wang, J; Duan, Y; Shang, D; Fu, Z

    2014-01-01

    The objective of the study was to compare geometrical differences of target volumes based on four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images of primary thoracic esophageal cancer for radiation treatment. Twenty-one patients with thoracic esophageal cancer sequentially underwent contrast-enhanced three-dimensional computed tomography (3DCT), 4DCT, and 18F-FDG PET/CT thoracic simulation scans during normal free breathing. The internal gross target volume defined as IGTVMIP was obtained by contouring on MIP images. The gross target volumes based on PET/CT images (GTVPET ) were determined with nine different standardized uptake value (SUV) thresholds and manual contouring: SUV≥2.0, 2.5, 3.0, 3.5 (SUVn); ≥20%, 25%, 30%, 35%, 40% of the maximum (percentages of SUVmax, SUVn%). The differences in volume ratio (VR), conformity index (CI), and degree of inclusion (DI) between IGTVMIP and GTVPET were investigated. The mean centroid distance between GTVPET and IGTVMIP ranged from 4.98 mm to 6.53 mm. The VR ranged from 0.37 to 1.34, being significantly (P<0.05) closest to 1 at SUV2.5 (0.94), SUV20% (1.07), or manual contouring (1.10). The mean CI ranged from 0.34 to 0.58, being significantly closest to 1 (P<0.05) at SUV2.0 (0.55), SUV2.5 (0.56), SUV20% (0.56), SUV25% (0.53), or manual contouring (0.58). The mean DI of GTVPET in IGTVMIP ranged from 0.61 to 0.91, and the mean DI of IGTVMIP in GTVPET ranged from 0.34 to 0.86. The SUV threshold setting of SUV2.5, SUV20% or manual contouring yields the best tumor VR and CI with internal-gross target volume contoured on MIP of 4DCT dataset, but 3DPET/CT and 4DCT MIP could not replace each other for motion encompassing target volume delineation for radiation treatment. © 2014 International Society for Diseases of the Esophagus.

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  4. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  7. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  8. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    International Nuclear Information System (INIS)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo

    2016-01-01

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment

  9. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2016-06-15

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment.

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  12. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches

    NARCIS (Netherlands)

    Nada, R.M.; Maal, T.J.J.; Breuning, K.H.; Berge, S.J.; Mostafa, Y.A.; Kuijpers-Jagtman, A.M.

    2011-01-01

    Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans.

  13. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  15. Quantifying Appropriate PTV Setup Margins: Analysis of Patient Setup Fidelity and Intrafraction Motion Using Post-Treatment Megavoltage Computed Tomography Scans

    International Nuclear Information System (INIS)

    Drabik, Donata M.; MacKenzie, Marc A.; Fallone, Gino B.

    2007-01-01

    Purpose: To present a technique that can be implemented in-house to evaluate the efficacy of immobilization and image-guided setup of patients with different treatment sites on helical tomotherapy. This technique uses an analysis of alignment shifts between kilovoltage computed tomography and post-treatment megavoltage computed tomography images. The determination of the shifts calculated by the helical tomotherapy software for a given site can then be used to define appropriate planning target volume internal margins. Methods and Materials: Twelve patients underwent post-treatment megavoltage computed tomography scans on a helical tomotherapy machine to assess patient setup fidelity and net intrafraction motion. Shifts were studied for the prostate, head and neck, and glioblastoma multiforme. Analysis of these data was performed using automatic and manual registration of the kilovoltage computed tomography and post-megavoltage computed tomography images. Results: The shifts were largest for the prostate, followed by the head and neck, with glioblastoma multiforme having the smallest shifts in general. It appears that it might be more appropriate to use asymmetric planning target volume margins. Each margin value reported is equal to two standard deviations of the average shift in the given direction. Conclusion: This method could be applied using individual patient post-image scanning and combined with adaptive planning to reduce or increase the margins as appropriate

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  18. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  19. Simulation-Based Planning of Optimal Conditions for Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Reisinger, S.; Kasperl, S.; Franz, M.

    2011-01-01

    We present a method to optimise conditions for industrial computed tomography (CT). This optimisation is based on a deterministic simulation. Our algorithm finds task-specific CT equipment settings to achieve optimal exposure parameters by means of an STL-model of the specimen and a raytracing...

  20. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  1. Evaluation of diffuse large B-cell lymphoma patients with 64-slice multidetector computed tomography versus 18FDG positron emission tomography/computed tomography in initial staging and restaging after treatment.

    Science.gov (United States)

    Gómez León, Nieves; Vega, Gema; Rodríguez-Vigil Junco, Beatriz; Suevos Ballesteros, Carlos

    2018-04-25

    To prospectively compare the accuracy in initial staging and end-of-treatment restaging of diffuse large B-cell lymphoma (DLBCL) between 64-slice multidetector computed tomography (64MDCT) and 18FDG positron emission tomography/computed tomography (18FGD PET/CT) with intravenous contrast injection. Randomised and blind controlled clinical multicentric trial that included biopsy-proven DLBCL patients. Seventy-two patients from five different hospitals in the region of Madrid, Spain, were enrolled in the study between January 2012 and June 2015. Thirty-six were randomly allocated to 18FDG PET/TC and the other 36 to 64MDCT for initial staging and end-of-treatment restaging. A nuclear medicine physician and a radiologist independently analysed 18FDG PET/TC images and reached an agreement post-hoc. 64MDCT images were separately evaluated by a different radiologist. Every set of images was compared to the reference standard that included clinical data, complementary tests and follow-up. The study was approved by participating centres' ethics committees and written informed consent was obtained from all the participants. A good agreement was observed between both diagnostic techniques and the reference standard in initial staging [18FDG PET/CT (k=0.5) and 64MDCT (k=0.6)], although only the 18FDG PET/TC showed a good agreement with the reference standard for the end-of-treatment restaging (k=0.7). In DLBCL, both 18FDG PET/TC and 64MDCT have shown good agreement with the reference standard in initial staging. Nevertheless, 18FDG PET/CT has shown to be superior to 64MDCT in end-of-treatment response assessment. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  2. Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy

    NARCIS (Netherlands)

    Parodi, Katia; Paganetti, Harald; Shih, Helen A; Michaud, Susan; Loeffler, Jay S; DeLaney, Thomas F; Liebsch, Norbert J; Munzenrider, John E; Fischman, Alan J; Knopf, Antje; Bortfeld, Thomas

    2007-01-01

    PURPOSE: To investigate the feasibility and value of positron emission tomography and computed tomography (PET/CT) for treatment verification after proton radiotherapy. METHODS AND MATERIALS: This study included 9 patients with tumors in the cranial base, spine, orbit, and eye. Total doses of 1.8-3

  3. Registration-based Reconstruction of Four-dimensional Cone Beam Computed Tomography

    DEFF Research Database (Denmark)

    Christoffersen, Christian; Hansen, David Christoffer; Poulsen, Per Rugaard

    2013-01-01

    We present a new method for reconstruction of four-dimensional (4D) cone beam computed tomography from an undersampled set of X-ray projections. The novelty of the proposed method lies in utilizing optical flow based registration to facilitate that each temporal phase is reconstructed from the full...

  4. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  5. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  8. Technical aspects of positron emission tomography/computed tomography in radiotherapy treatment planning.

    Science.gov (United States)

    Scripes, Paola G; Yaparpalvi, Ravindra

    2012-09-01

    The usage of functional data in radiation therapy (RT) treatment planning (RTP) process is currently the focus of significant technical, scientific, and clinical development. Positron emission tomography (PET) using ((18)F) fluorodeoxyglucose is being increasingly used in RT planning in recent years. Fluorodeoxyglucose is the most commonly used radiotracer for diagnosis, staging, recurrent disease detection, and monitoring of tumor response to therapy (Lung Cancer 2012;76:344-349; Lung Cancer 2009;64:301-307; J Nucl Med 2008;49:532-540; J Nucl Med 2007;48:58S-67S). All the efforts to improve both PET and computed tomography (CT) image quality and, consequently, lesion detectability have a common objective to increase the accuracy in functional imaging and thus of coregistration into RT planning systems. In radiotherapy, improvement in target localization permits reduction of tumor margins, consequently reducing volume of normal tissue irradiated. Furthermore, smaller treated target volumes create the possibility of dose escalation, leading to increased chances of tumor cure and control. This article focuses on the technical aspects of PET/CT image acquisition, fusion, usage, and impact on the physics of RTP. The authors review the basic elements of RTP, modern radiation delivery, and the technical parameters of coregistration of PET/CT into RT computerized planning systems. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  11. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  12. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung

    2001-01-01

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  13. Diagnosis and treatment of postoperative intraperitoneal abscess using ultrasonography and abdominal computed tomography

    International Nuclear Information System (INIS)

    Kamachi, Hisashi; Kumashiro, Ryunosuke; Maekawa, Takafumi; Saku, Haruhisa; Naitoh, Hideaki; Inutsuka, Sadamitsu; Higashi, Yoshitaka

    1988-01-01

    Ultrasonography and/or abdominal computed tomography revealed 9 patients with subphrenic abscesses derived from gastrointestinal surgery. Out of them 4 cases underwent conservative treatment is chosen with aggresive chemotherapy, but 5 were re-surgically treated including drainage of the intraperitonial abscess or repairing the leakage of the anastomosis. On the conservative treatment for the intraperitonial abscess, frequent monitoring with ultrasonography was very conventional for successful treatment. However, in the cases with severe leukocytosis, leakage of anastomosis or recurrent intraperitonial abscess, resurgical treatment will be required. Thus the monitoring with ultrasonography is quite usefull not only in the drainaging of the intraperitonial abscess, but also in the judgement of treatment whether conservetive or re-operative. (author)

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  15. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  16. Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

    Science.gov (United States)

    Karki, Kishor; Saraiya, Siddharth; Hugo, Geoffrey D; Mukhopadhyay, Nitai; Jan, Nuzhat; Schuster, Jessica; Schutzer, Matthew; Fahrner, Lester; Groves, Robert; Olsen, Kathryn M; Ford, John C; Weiss, Elisabeth

    2017-09-01

    To investigate interobserver delineation variability for gross tumor volumes of primary lung tumors and associated pathologic lymph nodes using magnetic resonance imaging (MRI), and to compare the results with computed tomography (CT) alone- and positron emission tomography (PET)-CT-based delineations. Seven physicians delineated the tumor volumes of 10 patients for the following scenarios: (1) CT only, (2) PET-CT fusion images registered to CT ("clinical standard"), and (3) postcontrast T1-weighted MRI registered with diffusion-weighted MRI. To compute interobserver variability, the median surface was generated from all observers' contours and used as the reference surface. A physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest wall) on the median surface. Contoured volumes and bidirectional local distances between individual observers' contours and the reference contour were analyzed. Computed tomography- and MRI-based tumor volumes normalized relative to PET-CT-based volumes were 1.62 ± 0.76 (mean ± standard deviation) and 1.38 ± 0.44, respectively. Volume differences between the imaging modalities were not significant. Between observers, the mean normalized volumes per patient averaged over all patients varied significantly by a factor of 1.6 (MRI) and 2.0 (CT and PET-CT) (P=4.10 × 10 -5 to 3.82 × 10 -9 ). The tumor-atelectasis interface had a significantly higher variability than other interfaces for all modalities combined (P=.0006). The interfaces with the smallest uncertainties were tumor-lung (on CT) and tumor-mediastinum (on PET-CT and MRI). Although MRI-based contouring showed overall larger variability than PET-CT, contouring variability depended on the interface type and was not significantly different between modalities, despite the limited observer experience with MRI. Multimodality imaging and combining different imaging characteristics might be the best approach to define

  17. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  18. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  19. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  20. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  1. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  2. Hepatocellular carcinoma: computed tomography assessment after invasive treatment

    International Nuclear Information System (INIS)

    Kozima, Shigeru; Larranaga, Nebil; Wulfson, Gabriela; Eisele, Guillermo; Ridruejo, Ezequiel; Mando, Oscar; Perazzo, Florencia

    2008-01-01

    Objective: To show the computed tomography (CT) usefulness after treatment with transcatheter arterial quimioembolization and radiofrequency ablation of hepatocellular carcinoma. Material and methods: In a period between march 2006 to april 2008 a total of 90 patient presenting 148 nodular lesions with diagnosis of hepatocellular carcinoma were controlled with triphasic CT. All the lesions were treated with minimally invasive procedure. For the treatment, the patients were classified in two groups following Milan criteria. The first group, constituted by 75 patients with 109 nodules, was treated with quimioembolization. The second group, of 15 patients with 25 nodules, was treated with radiofrequency ablation. In our population, a subgroup of 10 patients was treated with both methods. Results: Of 90 patients after CT control on a month, 3 months and for each 3 months during 2 years, on 63 cases (70%) was observed homogeneous accumulation of iodized oil, partial defect without enhancement or absence of enhancement on treated lesions. In these patients a new treatment after initial one was not performed. The remaining 27 patients (30%) underwent new treatment because we founded partial defect or absence of iodized oil with enhancement or peripheral enhancement on arterial phase in treated lesions. In this last group, 16 treated patients (17.7%) had new nodular enhancement on the remaining hepatic parenquimal. Conclusion: The CT unenhanced and the arterial phase on a month and for each 3 months, allow monitoring the effectiveness, residual disease and/or relapse of hepatocellular carcinoma after minimally invasive treatment. (authors) [es

  3. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  4. Cone-beam computed tomography-based diagnosis and treatment simulation for a patient with a protrusive profile and a gummy smile

    Science.gov (United States)

    Imamura, Toshihiro; Kokai, Satoshi; Ono, Takashi

    2018-01-01

    For patients with bimaxillary protrusion, significant retraction and intrusion of the anterior teeth are sometimes essential to improve the facial profile. However, severe root resorption of the maxillary incisors occasionally occurs after treatment because of various factors. For instance, it has been reported that approximation or invasion of the incisive canal by the anterior tooth roots during retraction may cause apical root damage. Thus, determination of the position of the maxillary incisors is key for orthodontic diagnosis and treatment planning in such cases. Cone-beam computed tomography (CBCT) may be useful for simulating the post-treatment position of the maxillary incisors and surrounding structures in order to ensure safe teeth movement. Here, we present a case of Class II malocclusion with bimaxillary protrusion, wherein apical root damage due to treatment was minimized by pretreatment evaluation of the anatomical structures and simulation of the maxillary central incisor movement using CBCT. Considerable retraction and intrusion of the maxillary incisors, which resulted in a significant improvement in the facial profile and smile, were achieved without severe root resorption. Our findings suggest that CBCT-based diagnosis and treatment simulation may facilitate safe and dynamic orthodontic tooth movement, particularly in patients requiring maximum anterior tooth retraction. PMID:29732305

  5. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  6. Total variation-based neutron computed tomography

    Science.gov (United States)

    Barnard, Richard C.; Bilheux, Hassina; Toops, Todd; Nafziger, Eric; Finney, Charles; Splitter, Derek; Archibald, Rick

    2018-05-01

    We perform the neutron computed tomography reconstruction problem via an inverse problem formulation with a total variation penalty. In the case of highly under-resolved angular measurements, the total variation penalty suppresses high-frequency artifacts which appear in filtered back projections. In order to efficiently compute solutions for this problem, we implement a variation of the split Bregman algorithm; due to the error-forgetting nature of the algorithm, the computational cost of updating can be significantly reduced via very inexact approximate linear solvers. We present the effectiveness of the algorithm in the significantly low-angular sampling case using synthetic test problems as well as data obtained from a high flux neutron source. The algorithm removes artifacts and can even roughly capture small features when an extremely low number of angles are used.

  7. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  8. GPU-based cone beam computed tomography.

    Science.gov (United States)

    Noël, Peter B; Walczak, Alan M; Xu, Jinhui; Corso, Jason J; Hoffmann, Kenneth R; Schafer, Sebastian

    2010-06-01

    The use of cone beam computed tomography (CBCT) is growing in the clinical arena due to its ability to provide 3D information during interventions, its high diagnostic quality (sub-millimeter resolution), and its short scanning times (60 s). In many situations, the short scanning time of CBCT is followed by a time-consuming 3D reconstruction. The standard reconstruction algorithm for CBCT data is the filtered backprojection, which for a volume of size 256(3) takes up to 25 min on a standard system. Recent developments in the area of Graphic Processing Units (GPUs) make it possible to have access to high-performance computing solutions at a low cost, allowing their use in many scientific problems. We have implemented an algorithm for 3D reconstruction of CBCT data using the Compute Unified Device Architecture (CUDA) provided by NVIDIA (NVIDIA Corporation, Santa Clara, California), which was executed on a NVIDIA GeForce GTX 280. Our implementation results in improved reconstruction times from minutes, and perhaps hours, to a matter of seconds, while also giving the clinician the ability to view 3D volumetric data at higher resolutions. We evaluated our implementation on ten clinical data sets and one phantom data set to observe if differences occur between CPU and GPU-based reconstructions. By using our approach, the computation time for 256(3) is reduced from 25 min on the CPU to 3.2 s on the GPU. The GPU reconstruction time for 512(3) volumes is 8.5 s. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  9. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  10. Computer-based quantitative computed tomography image analysis in idiopathic pulmonary fibrosis: A mini review.

    Science.gov (United States)

    Ohkubo, Hirotsugu; Nakagawa, Hiroaki; Niimi, Akio

    2018-01-01

    Idiopathic pulmonary fibrosis (IPF) is the most common type of progressive idiopathic interstitial pneumonia in adults. Many computer-based image analysis methods of chest computed tomography (CT) used in patients with IPF include the mean CT value of the whole lungs, density histogram analysis, density mask technique, and texture classification methods. Most of these methods offer good assessment of pulmonary functions, disease progression, and mortality. Each method has merits that can be used in clinical practice. One of the texture classification methods is reported to be superior to visual CT scoring by radiologist for correlation with pulmonary function and prediction of mortality. In this mini review, we summarize the current literature on computer-based CT image analysis of IPF and discuss its limitations and several future directions. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  11. Computed tomography scan based prediction of the vulnerable carotid plaque

    DEFF Research Database (Denmark)

    Diab, Hadi Mahmoud Haider; Rasmussen, Lars Melholt; Duvnjak, Stevo

    2017-01-01

    BACKGROUND: Primary to validate a commercial semi-automated computed tomography angiography (CTA) -software for vulnerable plaque detection compared to histology of carotid endarterectomy (CEA) specimens and secondary validating calcifications scores by in vivo CTA with ex vivo non......-contrast enhanced computed tomography (NCCT). METHODS: From January 2014 to October 2016 53 patients were included retrospectively, using a cross-sectional design. All patients underwent both CTA and CEA. Sixteen patients had their CEA specimen NCCT scanned. The semi-automated CTA software analyzed carotid stenosis...

  12. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  13. Computed tomography assessment of early response to neoadjuvant therapy in colon cancer

    DEFF Research Database (Denmark)

    Dam, Claus; Lund-Rasmussen, Vera; Pløen, John

    2015-01-01

    INTRODUCTION: Using multidetector computed tomography, we aimed to assess the early response of neoadjuvant drug therapy for locally advanced colon cancer. METHODS: Computed tomography with IV contrast was acquired from 67 patients before and after up to three cycles of preoperative treatment. All...

  14. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  15. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  16. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  17. Positron computed tomography with fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Hervouet, T.; Kraeber-Bodere, F.; Lamy, T.; Le Gouil, S.; Devillers, A.; Bodet-Milin, C.; Ansquer, C.; Cheze-le Rest, C.; Metges, J.P.; Teyton, P.; Lozach, P.; Volant, A.; Bizais, Y.; Visvikis, D.; Morel, O.; Girault, S.; Soulie, P.; Dupoiron, D.; Berthelot, C.; Lorimier, G.; Jallet, P.; Garin, E.; Prigent, F.; Lesimple, T.; Barge, M.L.; Rousseau, C.; Devillers, A.; Bernard, A.M.; Bouriel, C.; Bridji, B.; Resche, R.; Banayan, S.; Claret, M.; Ninet, J.; Janier, M.; Billotey, C.; Garin, E.; Devillers, A.; Becker, S.; Lecloirec, J.; Boucher, E.; Raoul, J.L.; Rolland, V.; Oudoux, A.; Valette, F.; Dupas, B.; Moreau, P.; Champion, L.; Anract, P.; Wartski, M.; Laurence, V.; Goldwasser, F.; Pecking, A.P.; Alberini, J.L.; Brillouet, S.; Caselles, O.; Allal, B.; Zerdoud, S.; Gansel, M.G.; Thomas, F.; Dierrickx, L.; Delord, J.P.; Marchand, C.; Resche, I.; Mahe, M.A.

    2006-01-01

    Several oral communications present the interest of positron computed tomography with fluorodeoxyglucose in the detection of cancers, or for the follow up of cancers treatments in order to detect early possible relapses.PET FDG is also used to optimize the definition of target volume in order to avoid side effects and to get a better control of the illness. (N.C.)

  18. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  19. Nonoperative treatment of splenic trauma: usefulness of computed tomography; Tratamento conservador do trauma esplenico: utilidade da tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Resende, Vivian [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Medicina; Tavares Junior, Wilson Campos; Vieira, Jose Nelson Mendes [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Dept. de Radiologia e Diagnostico por Imagem]. E-mail: wilsontavaresjrmd@yahoo.fr; Drumond, Domingos Andre Fernandes [Hospital Joao XXIII, Belo Horizonte, MG (Brazil). Setor de Clinica Cirurgica

    2005-04-15

    Objective: to report the results of use of conservative treatment in patients with splenic trauma and to emphasize the usefulness of computed tomography in these cases. Material and method: sixty-nine cases of pediatric patients with blunt abdominal trauma seen from from January 2001 to June 2004 at the level I trauma center were retrospectively studied. Forty-four of these patients were submitted to nonoperative treatment and the clinical follow-up was performed by computerized tomography. All patients had been diagnosed with splenic injury by computerized tomography.Results: the causes of the injuries were motor vehicle accident in 12 (27.2%) patients, bicycle accident in nine (20.4%) patients, and falls in 23 (52.2%) patients. Two (3.7%) patients died from associated injuries. The mean duration of hospital stay was six days. The mean age of the patients was nine years. Conclusion: conservative treatment for blunt splenic trauma is performed with the aim of reducing costs and risks for the patients, and computerized tomography should be routinely used. No posterior complications were observed in this approach. (author)

  20. Computed tomography of the ossicles

    International Nuclear Information System (INIS)

    Chakeres, D.W.; Weider, D.J.

    1985-01-01

    Otologists and otolaryngologists have described in detail the disorders which are unique to the ossicles. However the anatomy and spectrum of pathology and anatomy of the ossicles are not familiar to most radiologists. Recent advances in computed tomography (CT) and a systematic approach to evaluation now allow accurate identification of even subtle abnormalities of the ossicles. We present the normal anatomy, ossicular abnormalities, and indications for computed tomographic study. Because of the greater diagnostic capability of CT, the radiologist's role has increased in evaluation and treatment planning of patients with suspected ossicular abnormalities. (orig.)

  1. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    Science.gov (United States)

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  2. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Schom, C.; Engelke, W.; Kopka, L.; Fischer, U.; Grabbe, E.

    1996-01-01

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.) [de

  3. A proposal for standardizing computed tomography reports on abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Torlai, Fabiola Goda; Meirelles, Gustavo S. Portes; Miranda Junior, Fausto; Fonseca, Jose Honorio A.P. da; Ajzen, Sergio; D'Ippolito, Giuseppe

    2006-01-01

    Objective: to propose a model to standardize computed tomography reports on abdominal aortic aneurysms. Materials and methods: interviews were carried out with members of the Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5% (5/9). Results: the most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms were: maximum diameter of proximal aortic neck, proximal aortic neck length to lower renal arteries, shape of proximal aortic neck, maximum diameter of the aneurysm and diameter of the common iliac arteries. These data allowed the development of a proposal for a model to standardize computed tomography reports. Conclusion: a model for standardized tomographic analysis of abdominal aortic aneurysms has met vascular surgeons' needs for following-up patients and planning their treatment. (author)

  4. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  5. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  6. Computed tomography evaluation of petrous bone fractures ...

    African Journals Online (AJOL)

    Background: Petrous bone trauma is the sequel of blunt head injury and can have life threatening complications resulting in immediate mortality. Early detection and good knowledge of the Computed Tomography (CT) findings ensure prompt treatment of both fractures and complications. Objective: To document the ...

  7. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  8. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  9. Apical root resorption due to orthodontic treatment detected by cone beam computed tomography.

    Science.gov (United States)

    Castro, Iury O; Alencar, Ana H G; Valladares-Neto, José; Estrela, Carlos

    2013-03-01

    To determine the frequency of apical root resorption (ARR) due to orthodontic treatment using cone beam computed tomography (CBCT) in a sample of 1256 roots from 30 patients. All patients had Class I malocclusion with crowding. Of the 30 patients evaluated, 11 were boys and 19 were girls; their mean age was 13 years (11 to 16 years). Orthodontic treatment followed the nonextraction treatment. CBCT images were obtained before and after orthodontic treatment, and ARR was determined using Axial Guided Navigation of CBCT images. All patients had ARR. No statistically significant association was found between resorption frequency, gender, and age. ARR was detected using CBCT in 46% of all roots that underwent orthodontic treatment. CBCT was effective for detecting in vivo even minimal degrees of ARR due to orthodontic treatment and allowed three-dimensional evaluation of dental roots and visualization of palatine roots of maxillary molars. The highest frequencies and the most significant ARR occurred in incisors and distal roots of first maxillary and mandibular molars.

  10. Prediction of lung density changes after radiotherapy by cone beam computed tomography response markers and pre-treatment factors for non-small cell lung cancer patients.

    Science.gov (United States)

    Bernchou, Uffe; Hansen, Olfred; Schytte, Tine; Bertelsen, Anders; Hope, Andrew; Moseley, Douglas; Brink, Carsten

    2015-10-01

    This study investigates the ability of pre-treatment factors and response markers extracted from standard cone-beam computed tomography (CBCT) images to predict the lung density changes induced by radiotherapy for non-small cell lung cancer (NSCLC) patients. Density changes in follow-up computed tomography scans were evaluated for 135 NSCLC patients treated with radiotherapy. Early response markers were obtained by analysing changes in lung density in CBCT images acquired during the treatment course. The ability of pre-treatment factors and CBCT markers to predict lung density changes induced by radiotherapy was investigated. Age and CBCT markers extracted at 10th, 20th, and 30th treatment fraction significantly predicted lung density changes in a multivariable analysis, and a set of response models based on these parameters were established. The correlation coefficient for the models was 0.35, 0.35, and 0.39, when based on the markers obtained at the 10th, 20th, and 30th fraction, respectively. The study indicates that younger patients without lung tissue reactions early into their treatment course may have minimal radiation induced lung density increase at follow-up. Further investigations are needed to examine the ability of the models to identify patients with low risk of symptomatic toxicity. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  12. The diagnostic value of single-photon emission computed tomography/computed tomography for severe sacroiliac joint dysfunction.

    Science.gov (United States)

    Tofuku, Katsuhiro; Koga, Hiroaki; Komiya, Setsuro

    2015-04-01

    We aimed to evaluate the value of single-photon emission computed tomography (SPECT)/computed tomography (CT) for the diagnosis of sacroiliac joint (SIJ) dysfunction. SPECT/CT was performed in 32 patients with severe SIJ dysfunction, who did not respond to 1-year conservative treatment and had a score of >4 points on a 10-cm visual analog scale. We investigated the relationship between the presence of severe SIJ dysfunction and tracer accumulation, as confirmed by SPECT/CT. In cases of bilateral SIJ dysfunction, we also compared the intensity of tracer accumulation on each side. Moreover, we examined the relationship between the intensity of tracer accumulation and the different treatments the patients subsequently received. All 32 patients with severe SIJ dysfunction had tracer accumulation with a standardized uptake value (SUV) of >2.2 (mean SUV 4.7). In the 19 patients with lateralized symptom intensity, mean SUVs of the dominant side were significantly higher than those of the nondominant side. In 10 patients with no lateralization, the difference in the SUVs between sides was dysfunction as well as a useful technique for predicting the prognosis of this condition.

  13. Prediction of lung density changes after radiotherapy by cone beam computed tomography response markers and pre-treatment factors for non-small cell lung cancer patients

    DEFF Research Database (Denmark)

    Bernchou, Uffe; Hansen, Olfred; Schytte, Tine

    2015-01-01

    BACKGROUND AND PURPOSE: This study investigates the ability of pre-treatment factors and response markers extracted from standard cone-beam computed tomography (CBCT) images to predict the lung density changes induced by radiotherapy for non-small cell lung cancer (NSCLC) patients. METHODS...... AND MATERIALS: Density changes in follow-up computed tomography scans were evaluated for 135 NSCLC patients treated with radiotherapy. Early response markers were obtained by analysing changes in lung density in CBCT images acquired during the treatment course. The ability of pre-treatment factors and CBCT...

  14. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  15. Role of Cone Beam Computed Tomography in Diagnosis and Treatment Planning in Dentistry: An Update.

    Science.gov (United States)

    Shukla, Sagrika; Chug, Ashi; Afrashtehfar, Kelvin I

    2017-11-01

    Accurate diagnosis and treatment planning are the backbone of any medical therapy; for this reason, cone beam computed tomography (CBCT) was introduced and has been widely used. CBCT technology provides a three-dimensional image viewing, enabling exact location and extent of lesions or any anatomical region. For the very same reason, CBCT can not only be used for surgical fields but also for fields such as endodontics, prosthodontics, and orthodontics for appropriate treatment planning and effective dental care. The aim and clinical significance of this review are to update dental clinicians on the CBCT applications in each dental specialty for an appropriate diagnosis and more predictable treatment.

  16. Radiomics-based differentiation of lung disease models generated by polluted air based on X-ray computed tomography data.

    Science.gov (United States)

    Szigeti, Krisztián; Szabó, Tibor; Korom, Csaba; Czibak, Ilona; Horváth, Ildikó; Veres, Dániel S; Gyöngyi, Zoltán; Karlinger, Kinga; Bergmann, Ralf; Pócsik, Márta; Budán, Ferenc; Máthé, Domokos

    2016-02-11

    Lung diseases (resulting from air pollution) require a widely accessible method for risk estimation and early diagnosis to ensure proper and responsive treatment. Radiomics-based fractal dimension analysis of X-ray computed tomography attenuation patterns in chest voxels of mice exposed to different air polluting agents was performed to model early stages of disease and establish differential diagnosis. To model different types of air pollution, BALBc/ByJ mouse groups were exposed to cigarette smoke combined with ozone, sulphur dioxide gas and a control group was established. Two weeks after exposure, the frequency distributions of image voxel attenuation data were evaluated. Specific cut-off ranges were defined to group voxels by attenuation. Cut-off ranges were binarized and their spatial pattern was associated with calculated fractal dimension, then abstracted by the fractal dimension -- cut-off range mathematical function. Nonparametric Kruskal-Wallis (KW) and Mann-Whitney post hoc (MWph) tests were used. Each cut-off range versus fractal dimension function plot was found to contain two distinctive Gaussian curves. The ratios of the Gaussian curve parameters are considerably significant and are statistically distinguishable within the three exposure groups. A new radiomics evaluation method was established based on analysis of the fractal dimension of chest X-ray computed tomography data segments. The specific attenuation patterns calculated utilizing our method may diagnose and monitor certain lung diseases, such as chronic obstructive pulmonary disease (COPD), asthma, tuberculosis or lung carcinomas.

  17. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  18. Management of Liver Cancer Argon-helium Knife Therapy with Functional Computer Tomography Perfusion Imaging.

    Science.gov (United States)

    Wang, Hongbo; Shu, Shengjie; Li, Jinping; Jiang, Huijie

    2016-02-01

    The objective of this study was to observe the change in blood perfusion of liver cancer following argon-helium knife treatment with functional computer tomography perfusion imaging. Twenty-seven patients with primary liver cancer treated with argon-helium knife and were included in this study. Plain computer tomography (CT) and computer tomography perfusion (CTP) imaging were conducted in all patients before and after treatment. Perfusion parameters including blood flows, blood volume, hepatic artery perfusion fraction, hepatic artery perfusion, and hepatic portal venous perfusion were used for evaluating therapeutic effect. All parameters in liver cancer were significantly decreased after argon-helium knife treatment (p knife therapy. Therefore, CTP imaging would play an important role for liver cancer management followed argon-helium knife therapy. © The Author(s) 2014.

  19. Model-based image reconstruction in X-ray computed tomography

    NARCIS (Netherlands)

    Zbijewski, Wojciech Bartosz

    2006-01-01

    The thesis investigates the applications of iterative, statistical reconstruction (SR) algorithms in X-ray Computed Tomography. Emphasis is put on various aspects of system modeling in statistical reconstruction. Fundamental issues such as effects of object discretization and algorithm

  20. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  1. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  2. Olfactory neuroblastoma: the long-term outcome and late toxicity of multimodal therapy including radiotherapy based on treatment planning using computed tomography

    International Nuclear Information System (INIS)

    Mori, Takashi; Onimaru, Rikiya; Onodera, Shunsuke; Tsuchiya, Kazuhiko; Yasuda, Koichi; Hatakeyama, Hiromitsu; Kobayashi, Hiroyuki; Terasaka, Shunsuke; Homma, Akihiro; Shirato, Hiroki

    2015-01-01

    Olfactory neuroblastoma (ONB) is a rare tumor originating from olfactory epithelium. Here we retrospectively analyzed the long-term treatment outcomes and toxicity of radiotherapy for ONB patients for whom computed tomography (CT) and three-dimensional treatment planning was conducted to reappraise the role of radiotherapy in the light of recent advanced technology and chemotherapy. Seventeen patients with ONB treated between July 1992 and June 2013 were included. Three patients were Kadish stage B and 14 were stage C. All patients were treated with radiotherapy with or without surgery or chemotherapy. The radiation dose was distributed from 50 Gy to 66 Gy except for one patient who received 40 Gy preoperatively. The median follow-up time was 95 months (range 8–173 months). The 5-year overall survival (OS) and relapse-free survival (RFS) rates were estimated at 88% and 74%, respectively. Five patients with stage C disease had recurrence with the median time to recurrence of 59 months (range 7–115 months). Late adverse events equal to or above Grade 2 in CTCAE v4.03 were observed in three patients. Multimodal therapy including radiotherapy with precise treatment planning based on CT simulation achieved an excellent local control rate with acceptable toxicity and reasonable overall survival for patients with ONB

  3. The clinical impact of high resolution computed tomography in patients with respiratory disease

    International Nuclear Information System (INIS)

    Screaton, Nicholas J.; Tasker, Angela D.; Flower, Christopher D.R.; Miller, Fiona N.A.C.; Patel, Bipen D.; Groves, Ashley; Lomas, David A.

    2011-01-01

    High resolution computed tomography is widely used to investigate patients with suspected diffuse lung disease. Numerous studies have assessed the diagnostic performance of this investigation, but the diagnostic and therapeutic impacts have received little attention. The diagnostic and therapeutic impacts of high resolution computed tomography in routine clinical practice were evaluated prospectively. All 507 referrals for high-resolution computed tomography over 12 months in two centres were included. Requesting clinicians completed questionnaires before and after the investigation detailing clinical indications, working diagnoses, confidence level in each diagnosis, planned investigations and treatments. Three hundred and fifty-four studies on 347 patients had complete data and were available for analysis. Following high-resolution computed tomography, a new leading diagnosis (the diagnosis with the highest confidence level) emerged in 204 (58%) studies; in 166 (47%) studies the new leading diagnosis was not in the original differential diagnosis. Mean confidence in the leading diagnosis increased from 6.7 to 8.5 out of 10 (p < 0.001). The invasiveness of planned investigations increased in 23 (7%) studies and decreased in 124 (35%) studies. The treatment plan was modified after 319 (90%) studies. Thoracic high-resolution computed tomography alters leading diagnosis, increases diagnostic confidence, and frequently changes investigation and management plans. (orig.)

  4. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

    Science.gov (United States)

    Kinahan, Paul E; Hasegawa, Bruce H; Beyer, Thomas

    2003-07-01

    A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. Copyright 2003 Elsevier Inc. All rights reserved.

  5. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  6. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  7. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  8. Teleradiology for emergency cranial computed tomography

    International Nuclear Information System (INIS)

    Stranzinger, E.; Treumann, T.C.; Dreier, D.; Allgayer, B.

    2003-01-01

    Purpose: We report our experience with the teleradiologic service provided by a center hospital (CH) for emergency cranial computed tomography (CCT) in two regional hospitals (RH) during a 12-month period. The clinical and economic impact of teleradiology will be discussed as well as the acceptance by the clinicians of the regional hospitals. Material and Methods: In 2001, 213 CT-scans in 202 patients were performed and reported using teleradiology. Teleradiologic and final medical diagnosis were analysed by the medical reports. The transferral of the patients to a CH and their further treatment were checked. The referring physicians in the RH were questionnaired about the teleradiological support. Results: 18 (9%) patients had to be urgently transferred to a CH based on the CT findings in the teleradiological reports. 24 patients (11%) were transferred to a center hospital during further treatment. 80% of patients were treated in the RH. (orig.) [de

  9. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  10. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  11. Radiomics-based differentiation of lung disease models generated by polluted air based on X-ray computed tomography data

    International Nuclear Information System (INIS)

    Szigeti, Krisztián; Szabó, Tibor; Korom, Csaba; Czibak, Ilona; Horváth, Ildikó; Veres, Dániel S.; Gyöngyi, Zoltán; Karlinger, Kinga; Bergmann, Ralf; Pócsik, Márta; Budán, Ferenc; Máthé, Domokos

    2016-01-01

    Lung diseases (resulting from air pollution) require a widely accessible method for risk estimation and early diagnosis to ensure proper and responsive treatment. Radiomics-based fractal dimension analysis of X-ray computed tomography attenuation patterns in chest voxels of mice exposed to different air polluting agents was performed to model early stages of disease and establish differential diagnosis. To model different types of air pollution, BALBc/ByJ mouse groups were exposed to cigarette smoke combined with ozone, sulphur dioxide gas and a control group was established. Two weeks after exposure, the frequency distributions of image voxel attenuation data were evaluated. Specific cut-off ranges were defined to group voxels by attenuation. Cut-off ranges were binarized and their spatial pattern was associated with calculated fractal dimension, then abstracted by the fractal dimension -- cut-off range mathematical function. Nonparametric Kruskal-Wallis (KW) and Mann–Whitney post hoc (MWph) tests were used. Each cut-off range versus fractal dimension function plot was found to contain two distinctive Gaussian curves. The ratios of the Gaussian curve parameters are considerably significant and are statistically distinguishable within the three exposure groups. A new radiomics evaluation method was established based on analysis of the fractal dimension of chest X-ray computed tomography data segments. The specific attenuation patterns calculated utilizing our method may diagnose and monitor certain lung diseases, such as chronic obstructive pulmonary disease (COPD), asthma, tuberculosis or lung carcinomas. The online version of this article (doi:10.1186/s12880-016-0118-z) contains supplementary material, which is available to authorized users

  12. [CONE BEAM COMPUTED TOMOGRAPHY IN DIAGNOSTICS OF ODONTOGENIC MAXILLARY SINUSITIS (CASE REPORTS)].

    Science.gov (United States)

    Demidova, E; Khurdzidze, G

    2017-06-01

    Diagnostic studies performed by cone beam computed tomography Morita 3D made possible to obtain high resolution images of hard tissues of upper jawbone and maxillary sinus, to detect bony tissue defects, such as odontogenic cysts, cystogranulomas and granulomas. High-resolution and three dimensional tomographic image reconstructions allowed for optimal and prompt determination of the scope of surgical treatment and planning of effective conservative treatment regimen. Interactive diagnostics helped to estimate cosmetic and functional results of surgical treatment, to prevent the occurrence of surgical complications, and to evaluate the efficacy of conservative treatment. The obtained data contributed to determination of particular applications of cone beam computed tomography in the diagnosis of odontogenic maxillary sinusitis, detection of specific defects with cone beam tomography as the most informative method of diagnosis; as well as to determination of weak and strong sides, and helped to offer mechanisms of x-ray diagnostics to dental surgeons and ENT specialists.

  13. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  14. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  15. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  16. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  17. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  18. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shirvani, Shervin M.; Komaki, Ritsuko; Heymach, John V.; Fossella, Frank V.; Chang, Joe Y.

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non–small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39–86). The median follow-up duration was 21 months (range, 4–58) in all patients and 26 months (range, 4–58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive

  19. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shirvani, Shervin M.; Komaki, Ritsuko [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Heymach, John V.; Fossella, Frank V. [Department of Thoracic/Head and Neck Medical Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Chang, Joe Y., E-mail: jychang@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non-small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39-86). The median follow-up duration was 21 months (range, 4-58) in all patients and 26 months (range, 4-58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive intensity

  20. Impact of 18-fluorodeoxyglucose positron emission tomography on computed tomography defined target volumes in radiation treatment planning of esophageal cancer : reduction in geographic misses with equal inter-observer variability

    NARCIS (Netherlands)

    Schreurs, Liesbeth; Busz, D. M.; Paardekooper, G. M. R. M.; Beukema, J. C.; Jager, P. L.; Van der Jagt, E. J.; van Dam, G. M.; Groen, H.; Plukker, J. Th. M.; Langendijk, J. A.

    P>Target volume definition in modern radiotherapy is based on planning computed tomography (CT). So far, 18-fluorodeoxyglucose positron emission tomography (FDG-PET) has not been included in planning modality in volume definition of esophageal cancer. This study evaluates fusion of FDG-PET and CT in

  1. Mandibular condyle position in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Hyoung Joo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Kyung Hee Univ. School of Dentistry, Seoul (Korea, Republic of)

    2006-06-15

    To evaluate position of the mandibular condyle within articular fossa in an asymptomatic population radiographically by a cone beam computed tomography. Cone beam computed tomography of 60 temporomandibular joints was performed on 15 males and 15 females with no history of any temporomandibular disorders, or any other orthodontic or photoconductors treatments. Position of mandibular condyle within articular fossa at centric occlusion was evaluated. A statistical evaluation was done using a SPSS. In the sagittal views, mandibular condyle within articular fossa was laterally located at central section. Mandibular condyles in the right and left sides were showed asymmetric positional relationship at medial, central, and lateral sections. Mandibular condyle within articular fossa in an asymptomatic population was observed non-concentric position in the sagittal and coronal views.

  2. Usefulness of multi-detector row Computed Tomography for ...

    African Journals Online (AJOL)

    A 74-year-old female underwent surgical treatment for adenocarcinoma of the pancreatic head. Preoperative multi-detector row computed tomography (MD-CT) demonstrated tumor invasion into the accessory right colic vein and the branch of the middle colic artery (MCA), which was not detected by digital subtraction ...

  3. Radiative transport-based frequency-domain fluorescence tomography

    International Nuclear Information System (INIS)

    Joshi, Amit; Rasmussen, John C; Sevick-Muraca, Eva M; Wareing, Todd A; McGhee, John

    2008-01-01

    We report the development of radiative transport model-based fluorescence optical tomography from frequency-domain boundary measurements. The coupled radiative transport model for describing NIR fluorescence propagation in tissue is solved by a novel software based on the established Attila(TM) particle transport simulation platform. The proposed scheme enables the prediction of fluorescence measurements with non-contact sources and detectors at a minimal computational cost. An adjoint transport solution-based fluorescence tomography algorithm is implemented on dual grids to efficiently assemble the measurement sensitivity Jacobian matrix. Finally, we demonstrate fluorescence tomography on a realistic computational mouse model to locate nM to μM fluorophore concentration distributions in simulated mouse organs

  4. Analysis of interfractional variations in pancreatic position based on four-dimensional computed tomography

    International Nuclear Information System (INIS)

    Shiinoki, Takehiro; Itoh, Akio; Shibuya, Keiko; Nakamura, Mitsuhiro; Nakamura, Akira; Matsuo, Yukinori; Sawada, Akira; Mizowaki, Takashi; Hiraoka, Masahiro

    2010-01-01

    The purpose of this study was to assess inter-fractional variations in pancreatic position using four-dimensional computed tomography (4D-CT) and to find the suitable phase of respiration for breath-holding. The variations in respiratory motion range during treatment course and inter-fractional variations in pancreatic positions were not negligible; however, our study suggested that breath-holding at end-exhalation with some coaching techniques might be considerable one of the non-invasive approaches to get higher positional reproducibility of pancreatic tumors. (author)

  5. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  6. Grating-based X-ray Dark-field Computed Tomography of Living Mice.

    Science.gov (United States)

    Velroyen, A; Yaroshenko, A; Hahn, D; Fehringer, A; Tapfer, A; Müller, M; Noël, P B; Pauwels, B; Sasov, A; Yildirim, A Ö; Eickelberg, O; Hellbach, K; Auweter, S D; Meinel, F G; Reiser, M F; Bech, M; Pfeiffer, F

    2015-10-01

    Changes in x-ray attenuating tissue caused by lung disorders like emphysema or fibrosis are subtle and thus only resolved by high-resolution computed tomography (CT). The structural reorganization, however, is of strong influence for lung function. Dark-field CT (DFCT), based on small-angle scattering of x-rays, reveals such structural changes even at resolutions coarser than the pulmonary network and thus provides access to their anatomical distribution. In this proof-of-concept study we present x-ray in vivo DFCTs of lungs of a healthy, an emphysematous and a fibrotic mouse. The tomographies show excellent depiction of the distribution of structural - and thus indirectly functional - changes in lung parenchyma, on single-modality slices in dark field as well as on multimodal fusion images. Therefore, we anticipate numerous applications of DFCT in diagnostic lung imaging. We introduce a scatter-based Hounsfield Unit (sHU) scale to facilitate comparability of scans. In this newly defined sHU scale, the pathophysiological changes by emphysema and fibrosis cause a shift towards lower numbers, compared to healthy lung tissue.

  7. The value of three-dimensional helical computed tomography for the retrograde flexible ureteronephroscopy in the treatment of lower pole calyx stones

    Directory of Open Access Journals (Sweden)

    Yan Xu

    2016-03-01

    Full Text Available Objective: The aim of our study was to determine if there is any advantage of three-dimensional helical computed tomography (3D-HCT over intravenous urogram (IVU for the retrograde flexible ureteronephroscopy in the treatment of lower pole calyx stones. Methods: From June 2012 to January 2014, a total of 52 cases of lower pole renal stones underwent retrograde intrarenal surgery (RIRS in our center. All patients underwent a preoperative IVU and three-dimensional helical computed tomography urography (3D-CTU program to define the collecting system anatomy, manly concerning the following lower pole features; infundibu-lopelvic angle (IPA, infundibular length (IL, and infundibular width (IW. The examinations were performed in the same center of reference with a standardized method and with 3D-HCT Siemens Somaton Plus equipment. The measurements were performed by the same researcher, using a ruler and a square. Results: Based on clinical threshold difference of the anatomic factors on an IVU image to compare the difference between an IVU image and a 3D-CT image of 52 patients, the IPA was <30° when measured on intravenous pyelography (IVP for 21 patients. We found that with the IPA of <30° measured with IVP only 19% (4/21 were correctly classified in the same size category using 3D-HCT, whereas 81% (17/21 were upgraded to 40–50° on 3D-CT. This difference was significant between IVP and 3D-HCT. Conclusions: 3D-HCT has advantages over IVU when analyzing the morphometric and the morphological features of kidney lower pole spatial anatomy for the retrograde flexible ureteronephroscopy in the treatment of lower pole calyx stones. Keywords: Intravenous urogram, Computed tomography urography, Flexible ureterorenoscopy, Lower pole, Renal stones

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  9. Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning

    Directory of Open Access Journals (Sweden)

    Indra J Das

    2016-01-01

    Full Text Available Modern treatment planning systems provide accurate dosimetry in heterogeneous media (such as a patient' body with the help of tissue characterization based on computed tomography (CT number. However, CT number depends on the type of scanner, tube voltage, field of view (FOV, reconstruction algorithm including artifact reduction and processing filters. The impact of these parameters on CT to electron density (ED conversion had been subject of investigation for treatment planning in various clinical situations. This is usually performed with a tissue characterization phantom with various density plugs acquired with different tube voltages (kilovoltage peak, FOV reconstruction and different scanners to generate CT number to ED tables. This article provides an overview of inhomogeneity correction in the context of CT scanning and a new evaluation tool, difference volume dose-volume histogram (DVH, dV-DVH. It has been concluded that scanner and CT parameters are important for tissue characterizations, but changes in ED are minimal and only pronounced for higher density materials. For lungs, changes in CT number are minimal among scanners and CT parameters. Dosimetric differences for lung and prostate cases are usually insignificant (<2% in three-dimensional conformal radiation therapy and < 5% for intensity-modulated radiation therapy (IMRT with CT parameters. It could be concluded that CT number variability is dependent on acquisition parameters, but its dosimetric impact is pronounced only in high-density media and possibly in IMRT. In view of such small dosimetric changes in low-density medium, the acquisition of additional CT data for financially difficult clinics and countries may not be warranted.

  10. Head and neck: normal variations and benign findings in FDG positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-04-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Computed tomography-guided bupivacaine and corticosteroid injection for the treatment of symptomatic calcification in the great toe tendon

    Directory of Open Access Journals (Sweden)

    Karatoprak O

    2014-04-01

    Full Text Available Omer Karatoprak,1 Sinan Karaca,2 Mehmet Nuri Erdem,3 Ozgur Karaman,2 Azmi Hamzaoglu41Department of Orthopedic Surgery, Kadikoy Florence Nightingale Hospital, Istanbul, Turkey; 2Department of Orthopedic Surgery, Fatih Sultan Mehmet Training and Research Hospital Atasehir, Istanbul, Turkey; 3Department of Orthopedics and Traumatology, Kolan International Hospital Sisli, Istanbul, Turkey; 4Department of Orthopedic Surgery, Istanbul Florence Nightingale Hospital, Istanbul TurkeyBackground: Calcification in the great toe tendon is a rare disorder that is characterized by the deposition of calcium on degenerative collagen fibrils.Case presentations: In this report, we present two cases of calcific tendonitis: one in the adductor hallucis and the other in the flexor hallucis longus tendon. We preferred computed tomography-guided steroid injection in our cases because of pain unresponsive to conservative treatment. Patients were free of symptoms at the follow-up visit, 4 weeks after injection.Conclusion: Calcification of the hallux tendons is a rare disorder. Treatment of tendonitis consists of nonsteroidal anti-inflammatory drugs. Local anesthetic and steroid injection may be considered in cases unresponsive to conservative treatment. Because of the anatomic location of tendons, injection could be difficult. Computed tomography guidance may improve the success rate of injections.Keywords: bupivacaine, calcification, great toe tendons, corticosteroid injection

  12. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  13. A method for improved 4D-computed tomography data acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Kupper, Martin; Sprengel, Wolfgang [Technische Univ. Graz (Austria). Inst. fuer Materialphysik; Winkler, Peter; Zurl, Brigitte [Medizinische Univ. Graz (Austria). Comprehensive Cancer Center

    2017-05-01

    In four-dimensional time-dependent computed tomography (4D-CT) of the lungs, irregularities in breathing movements can cause errors in data acquisition, or even data loss. We present a method based on sending a synthetic, regular breathing signal to the CT instead of the real signal, which ensures 4D-CT data sets without data loss. Subsequent correction of the signal based on the real breathing curve enables an accurate reconstruction of the size and movement of the target volume. This makes it possible to plan radiation treatment based on the obtained data. The method was tested with dynamic thorax phantom measurements using synthetic and real breathing patterns.

  14. Comparison of Swedish and Norwegian Use of Cone-Beam Computed Tomography: a Questionnaire Study

    Directory of Open Access Journals (Sweden)

    Jerker Edén Strindberg

    2015-12-01

    Full Text Available Objectives: Cone-beam computed tomography in dentistry can be used in some countries by other dentists than specialists in radiology. The frequency of buying cone-beam computed tomography to examine patients is rapidly growing, thus knowledge of how to use it is very important. The aim was to compare the outcome of an investigation on the use of cone-beam computed tomography in Sweden with a previous Norwegian study, regarding specifically technical aspects. Material and Methods: The questionnaire contained 45 questions, including 35 comparable questions to Norwegian clinics one year previous. Results were based on inter-comparison of the outcome from each of the two questionnaire studies. Results: Responses rate was 71% in Sweden. There, most of cone-beam computed tomography (CBCT examinations performed by dental nurses, while in Norway by specialists. More than two-thirds of the CBCT units had a scout image function, regularly used in both Sweden (79% and Norway (75%. In Sweden 4% and in Norway 41% of the respondents did not wait for the report from the radiographic specialist before initiating treatment. Conclusions: The bilateral comparison showed an overall similarity between the two countries. The survey gave explicit and important knowledge of the need for education and training of the whole team, since radiation dose to the patient could vary a lot for the same kind of radiographic examination. It is essential to establish quality assurance protocols with defined responsibilities in the team in order to maintain high diagnostic accuracy for all examinations when using cone-beam computed tomography for patient examinations.

  15. Coronary Computed Tomography Angiography Derived Fractional Flow Reserve and Plaque Stress

    DEFF Research Database (Denmark)

    Nørgaard, Bjarne Linde; Leipsic, Jonathon; Koo, Bon-Kwon

    2016-01-01

    Fractional flow reserve (FFR) measured during invasive coronary angiography is an independent prognosticator in patients with coronary artery disease and the gold standard for decision making in coronary revascularization. The integration of computational fluid dynamics and quantitative anatomic...... and physiologic modeling now enables simulation of patient-specific hemodynamic parameters including blood velocity, pressure, pressure gradients, and FFR from standard acquired coronary computed tomography (CT) datasets. In this review article, we describe the potential impact on clinical practice...... and the science behind noninvasive coronary computed tomography (CT) angiography derived fractional flow reserve (FFRCT) as well as future applications of this technology in treatment planning and quantifying forces on atherosclerotic plaques....

  16. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  17. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  18. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  19. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  20. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  1. Comparison of Cone-Beam Computed Tomography and Periapical Radiography in Predicting Treatment Decision for Periapical Lesions: A Clinical Study

    Directory of Open Access Journals (Sweden)

    Ashok Balasundaram

    2012-01-01

    Full Text Available Objectives. To compare the ability of endodontists to determine the size of apical pathological lesions and select the most appropriate choice of treatment based on lesions’ projected image characteristics using 2 D and 3 D images. Study Design. Twenty-four subjects were selected. Radiographic examination of symptomatic study teeth with an intraoral periapical radiograph revealed periapical lesions equal to or greater than 3 mm in the greatest diameter. Cone-beam Computed tomography (CBCT images were made of the involved teeth after the intraoral periapical radiograph confirmed the size of lesion to be equal to greater than 3 mm. Six observers (endodontists viewed both the periapical and CBCT images. Upon viewing each of the images from the two imaging modalities, observers (1 measured lesion size and (2 made decisions on treatment based on each radiograph. Chi-square test was used to look for differences in the choice of treatment among observers. Results. No significant difference was noted in the treatment plan selected by observers using the two modalities (χ2(3=.036, P>0.05. Conclusion. Lesion size and choice of treatment of periapical lesions based on CBCT radiographs do not change significantly from those made on the basis of 2 D radiographs.

  2. General rigid motion correction for computed tomography imaging based on locally linear embedding

    Science.gov (United States)

    Chen, Mianyi; He, Peng; Feng, Peng; Liu, Baodong; Yang, Qingsong; Wei, Biao; Wang, Ge

    2018-02-01

    The patient motion can damage the quality of computed tomography images, which are typically acquired in cone-beam geometry. The rigid patient motion is characterized by six geometric parameters and are more challenging to correct than in fan-beam geometry. We extend our previous rigid patient motion correction method based on the principle of locally linear embedding (LLE) from fan-beam to cone-beam geometry and accelerate the computational procedure with the graphics processing unit (GPU)-based all scale tomographic reconstruction Antwerp toolbox. The major merit of our method is that we need neither fiducial markers nor motion-tracking devices. The numerical and experimental studies show that the LLE-based patient motion correction is capable of calibrating the six parameters of the patient motion simultaneously, reducing patient motion artifacts significantly.

  3. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  4. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  5. Single photon emission computed tomography in children with idiopathic seizures

    International Nuclear Information System (INIS)

    Hara, Masafumi; Takahashi, Mutsumasa; Kojima, Akihiro; Shimomura, Osamu; Kinoshita, Rumi; Tomiguchi, Seiji; Taku, Keiichi; Miike, Teruhisa

    1991-01-01

    Single photon emission computed tomography (SPECT) with N-isoprophyl-p [ 123 I]-iodoamphetamine (IMP), X-ray computed tomography (X-CT), and magnetic resonance imaging (MRI) were performed in 20 children with idiopathic seizures. In children with idiopathic seizures, SPECT could detect the abnormal sites at the highest rate (45%) compared with CT (10%) and MRI (12%), but the abnormal sites on SPECT correlated poorly with the foci on electroencephalograph (EEG). Idiopathic epilepsy with hypoperfusion on SPECT was refractory to treatment and was frequently associated with mental and/or developmental retardation. Perfusion defects on SPECT scans probably affect the development and maturation of the brain in children. (author)

  6. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  7. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... was to investigate the value of positron emission tomography using 2-[18F]fluoro-2-deoxy-D-glucose (FDG-PET) and combined FDG-PET/CT for the staging of HL patients, and the impact on the choice of treatment. DESIGN AND METHODS: Ninety-nine consecutive, prospectively included patients had FDG-PET and CT...

  8. A compressed sensing based reconstruction algorithm for synchrotron source propagation-based X-ray phase contrast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Melli, Seyed Ali, E-mail: sem649@mail.usask.ca [Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK (Canada); Wahid, Khan A. [Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK (Canada); Babyn, Paul [Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK (Canada); Montgomery, James [College of Medicine, University of Saskatchewan, Saskatoon, SK (Canada); Snead, Elisabeth [Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK (Canada); El-Gayed, Ali [College of Medicine, University of Saskatchewan, Saskatoon, SK (Canada); Pettitt, Murray; Wolkowski, Bailey [College of Agriculture and Bioresources, University of Saskatchewan, Saskatoon, SK (Canada); Wesolowski, Michal [Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK (Canada)

    2016-01-11

    Synchrotron source propagation-based X-ray phase contrast computed tomography is increasingly used in pre-clinical imaging. However, it typically requires a large number of projections, and subsequently a large radiation dose, to produce high quality images. To improve the applicability of this imaging technique, reconstruction algorithms that can reduce the radiation dose and acquisition time without degrading image quality are needed. The proposed research focused on using a novel combination of Douglas–Rachford splitting and randomized Kaczmarz algorithms to solve large-scale total variation based optimization in a compressed sensing framework to reconstruct 2D images from a reduced number of projections. Visual assessment and quantitative performance evaluations of a synthetic abdomen phantom and real reconstructed image of an ex-vivo slice of canine prostate tissue demonstrate that the proposed algorithm is competitive in reconstruction process compared with other well-known algorithms. An additional potential benefit of reducing the number of projections would be reduction of time for motion artifact to occur if the sample moves during image acquisition. Use of this reconstruction algorithm to reduce the required number of projections in synchrotron source propagation-based X-ray phase contrast computed tomography is an effective form of dose reduction that may pave the way for imaging of in-vivo samples.

  9. Ioversol 350: clinical experience in cranial computed tomography

    International Nuclear Information System (INIS)

    Theron, J.; Paugam, J.P.; Courtheoux, P.

    1991-01-01

    A single, open trial was conducted in 40 patients to evaluate the diagnostic efficacy and safety, in cranial computed tomography, of ioversol (350 mgl/ml), a new nonionic, monomeric, low-osmolality contrast medium. Ioversol is characterized by a hydrophilicity which is not only the highest of all nonionic agents available to date, but also evenly distributed among the various sides of the benzene ring. Diagnosis was possible in 100 % of cases with a mean degree of certainty of 90.8 %. Six minor adverse reactions requiring no treatment we recorded, of which two were observed by the investigator and four reported by the patients. No pain sensation was found and heat sensations were of minor intensity. Ioversol 350, which showed good diagnostic efficacy and proved to be well tolerated, is therefore suitable for cranial computed tomography at a mean dose of 1 ml/kg

  10. Computed tomography changes following cryotherapy for hepatic cancer

    International Nuclear Information System (INIS)

    King, J.; Morris, D. L.; Glenn, D.

    1997-01-01

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment

  11. Computed tomography and nonoperative treatment for blunt abdominal trauma

    International Nuclear Information System (INIS)

    Watanabe, Shinsuke; Ishi, Takashi; Kamachi, Masahiro; Takahashi, Toshio.

    1990-01-01

    Studies were undertaken to determine if computed tomography (CT) could reliably assist physical examination in the initial assessment of blunt abdominal trauma, and also to examine how various abdominal injuries were managed with the guidance of CT. A total of 255 patients underwent emergency abdominal CT following blunt abdominal trauma over a period of seven years. One hundred and fifty two patients had abnormal CT scans, including 58 hepatic, 36 renal, 25 splenic and 9 pancreatic injuries as well as 67 patients with intra-abdominal hemorrhage and 21 patients with free abdominal air. A comparative study on the detection of pneumoperitoneum revealed CT to be far superior to plain radiography. One hundred and three patients had normal CT scans, all of whom were managed nonoperatively, except for three false-negative cases and two nontherapeutic cases. The patients with injury to the parenchymal organs were given nonoperative treatment if they had stable vital signs and no evidence of associated injuries demanding immediate surgery and the majority of these patients were managed well nonoperatively. CT was thus found to be a useful adjunct in the management of victims of blunt abdominal trauma, since in a rapid and noninvasive fashion, CT accurately defined the extent of parenchymal organ injury and also disclosed any other abdominal injuries. (author)

  12. Computed tomography and nonoperative treatment for blunt abdominal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Shinsuke; Ishi, Takashi; Kamachi, Masahiro [Saiseikai Shiga Hospital, Shiga (Japan); Takahashi, Toshio

    1990-01-01

    Studies were undertaken to determine if computed tomography (CT) could reliably assist physical examination in the initial assessment of blunt abdominal trauma, and also to examine how various abdominal injuries were managed with the guidance of CT. A total of 255 patients underwent emergency abdominal CT following blunt abdominal trauma over a period of seven years. One hundred and fifty two patients had abnormal CT scans, including 58 hepatic, 36 renal, 25 splenic and 9 pancreatic injuries as well as 67 patients with intra-abdominal hemorrhage and 21 patients with free abdominal air. A comparative study on the detection of pneumoperitoneum revealed CT to be far superior to plain radiography. One hundred and three patients had normal CT scans, all of whom were managed nonoperatively, except for three false-negative cases and two nontherapeutic cases. The patients with injury to the parenchymal organs were given nonoperative treatment if they had stable vital signs and no evidence of associated injuries demanding immediate surgery and the majority of these patients were managed well nonoperatively. CT was thus found to be a useful adjunct in the management of victims of blunt abdominal trauma, since in a rapid and noninvasive fashion, CT accurately defined the extent of parenchymal organ injury and also disclosed any other abdominal injuries. (author).

  13. Value of radio density determined by enhanced computed tomography for the differential diagnosis of lung masses

    International Nuclear Information System (INIS)

    Xie, Min

    2011-01-01

    Lung masses are often difficult to differentiate when their clinical symptoms and shapes or densities on computed tomography images are similar. However, with different pathological contents, they may appear differently on plain and enhanced computed tomography. Objectives: To determine the value of enhanced computed tomography for the differential diagnosis of lung masses based on the differences in radio density with and without enhancement. Patients and Methods: Thirty-six patients with lung cancer, 36 with pulmonary tuberculosis and 10 with inflammatory lung pseudo tumors diagnosed by computed tomography and confirmed by pathology in our hospital were selected. The mean ±SD radio densities of lung masses in the three groups of patients were calculated based on the results of plain and enhanced computed tomography. Results: There were no significant differences in the radio densities of the masses detected by plain computed tomography among patients with inflammatory lung pseudo tumors, tuberculosis and lung cancer (P> 0.05). However, there were significant differences (P< 0.01)between all the groups in terms of radio densities of masses detected by enhanced computed tomography. Conclusions: The radio densities of lung masses detected by enhanced computed tomography could potentially be used to differentiate between lung cancer, pulmonary tuberculosis and inflammatory lung pseudo tumors.

  14. Duodenal diverticulitis. computed tomography findings

    International Nuclear Information System (INIS)

    Sanchez, E.; Martin, S.; Garcia, J.; Dominguez, A.

    2001-01-01

    Duodenal diverticular occur very frequently among the general public. However, duodenal diverticulitis is a very uncommon clinical entity, the diagnosis of which requires radiological studies since the clinical signs cam mimic a great number of disease processes with different treatments. We present a case of duodenal diverticulitis in which the diagnosis according to ultrasound and computed tomography (CT) studies was confirmed intraoperatively. We also review the few cases of this entity reported in the literature. The CT findings are highly suggestive of duodenal diverticulitis given their similarity to those associated with diverticulitis at other sites. (Author) 5 refs,

  15. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  16. The role of computed tomography in the laryngeal injury

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1984-01-01

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results

  17. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  18. Comparison of computed tomography and radiography for detecting changes induced by malignant nasal neoplasia in dogs

    International Nuclear Information System (INIS)

    Park, R.D.; Beck, E.R.; LeCouteur, R.A.

    1992-01-01

    The ability of computed tomography and radiography to detect changes associated with nasal neoplasia was compared in dogs. Eighteen areas or anatomic structures were evaluated in 21 dogs for changes indicative of neoplasia. Computed tomography was superior (P < or = 0.05) to radiography for detecting changes in 14 of 18 areas. Radiography was not superior for detecting changes in any structure or area. Computed tomography reveals vital information not always detected radiographically to assist in providing a prognosis and in planning treatment for nasal neoplasms in dogs

  19. Three Dimensional Digital Sieving of Asphalt Mixture Based on X-ray Computed Tomography

    OpenAIRE

    Chichun Hu; Jiexian Ma; M. Emin Kutay

    2017-01-01

    In order to perform three-dimensional digital sieving based on X-ray computed tomography images, the definition of digital sieve size (DSS) was proposed, which was defined as the minimum length of the minimum bounding squares of all possible orthographic projections of an aggregate. The corresponding program was developed to reconstruct aggregate structure and to obtain DSS. Laboratory experiments consisting of epoxy-filled aggregate specimens were conducted to investigate the difference betw...

  20. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  1. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography.

    Science.gov (United States)

    Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P

    2014-11-01

    Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  2. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended to...

  3. Use of 4-Dimensional Computed Tomography-Based Ventilation Imaging to Correlate Lung Dose and Function With Clinical Outcomes

    International Nuclear Information System (INIS)

    Vinogradskiy, Yevgeniy; Castillo, Richard; Castillo, Edward; Tucker, Susan L.; Liao, Zhongxing; Guerrero, Thomas; Martel, Mary K.

    2013-01-01

    Purpose: Four-dimensional computed tomography (4DCT)-based ventilation is an emerging imaging modality that can be used in the thoracic treatment planning process. The clinical benefit of using ventilation images in radiation treatment plans remains to be tested. The purpose of the current work was to test the potential benefit of using ventilation in treatment planning by evaluating whether dose to highly ventilated regions of the lung resulted in increased incidence of clinical toxicity. Methods and Materials: Pretreatment 4DCT data were used to compute pretreatment ventilation images for 96 lung cancer patients. Ventilation images were calculated using 4DCT data, deformable image registration, and a density-change based algorithm. Dose–volume and ventilation-based dose function metrics were computed for each patient. The ability of the dose–volume and ventilation-based dose–function metrics to predict for severe (grade 3+) radiation pneumonitis was assessed using logistic regression analysis, area under the curve (AUC) metrics, and bootstrap methods. Results: A specific patient example is presented that demonstrates how incorporating ventilation-based functional information can help separate patients with and without toxicity. The logistic regression significance values were all lower for the dose–function metrics (range P=.093-.250) than for their dose–volume equivalents (range, P=.331-.580). The AUC values were all greater for the dose–function metrics (range, 0.569-0.620) than for their dose–volume equivalents (range, 0.500-0.544). Bootstrap results revealed an improvement in model fit using dose–function metrics compared to dose–volume metrics that approached significance (range, P=.118-.155). Conclusions: To our knowledge, this is the first study that attempts to correlate lung dose and 4DCT ventilation-based function to thoracic toxicity after radiation therapy. Although the results were not significant at the .05 level, our data suggests

  4. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  5. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  6. Morphologic and Metabolic Comparison of Treatment Responsiveness with 18Fludeoxyglucose-Positron Emission Tomography/Computed Tomography According to Lung Cancer Type

    Directory of Open Access Journals (Sweden)

    Mehmet Fatih Börksüz

    2016-06-01

    Full Text Available Objective: The aim of the present study was to evaluate the response to treatment by histopathologic type in patients with lung cancer and under follow-up with 18F-fluoro-2deoxy-glucose-positron emission tomography/computed tomography (18F-FDG PET/CT imaging by using Response Evaluation Criteria in Solid Tumors (RECIST and European Organisation for Research and Treatment of Cancer (EORTC criteria that evaluate morphologic and metabolic parameters. Methods: On two separate (pre- and post-treatment 18F-FDG PET/CT images, the longest dimension of primary tumor as well as of secondary lesions were measured and sum of these two measurements was recorded as the total dimension in 40 patients. PET parameters such as standardized uptake value (SUVmax, metabolic volume and total lesion glycolysis (TLG were also recorded for these target lesions on two separate 18F-FDG PET/CT images. The percent (% change was calculated for all these parameters. Morphologic evaluation was based on RECIST 1.1 and the metabolic evaluation was based on EORTC. Results: When evaluated before and after treatment, in spite of the statistically significant change (p0.05. In histopathologic typing, when we compare the post-treatment phase change with the treatment responses of RECIST 1.1 and EORTC criteria; for RECIST 1.1 in squamous cell lung cancer group, progression was observed in sixteen patients (57%, stability in seven patients (25%, partial response in five patients (18%; and for EORTC progression was detected in four patients (14%, stability in thirteen patients (47%, partial response in eleven patients (39%, in 12 of these patients an increase in stage (43%, in 4 of them a decrease in stage (14%, and in 12 of them stability in stage (43% were determined. But in adenocancer patients (n=7, for RECIST 1.1, progression was determined in four patients (57%, stability in two patients (29%, partial response in one patient (14%; for EORTC, progression in one patient (14

  7. Computed tomography changes following cryotherapy for hepatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    King, J.; Morris, D. L. [University of NSW, Sydney (Australia). Department of Surgery; Glenn, D. [St George Hospital, Kogarah, Sydney (Australia). Department of Radiology

    1997-05-01

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment. 11 refs., 1 tab., 9 figs.

  8. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  9. The Role of Computed Tomography in Monitoring Patients with Cystic Fibrosis

    International Nuclear Information System (INIS)

    Rybacka, Anna; Karmelita-Katulska, Katarzyna

    2016-01-01

    Cystic fibrosis is the most common lethal autosomal recessive disorder in the Caucasian population. Although the survival rate in patients constantly improves, lung damage is still the major cause of morbidity and mortality in patients with cystic fibrosis. In clinical practice, evaluation of patients’ pulmonary state is made by combination of monitoring of lung function and more directly by assessing the lung structure in imaging studies. Studies showed that computed tomography findings are more sensitive as compared to the pulmonary function tests. Computed tomography can identify a wide range of morphological abnormalities in patients with cystic fibrosis, such as bronchiectasis (which is progressive, irreversible and probably the most relevant structural change in cystic fibrosis) peribronchial thickening, mucous plugging and many other disorders that occur in the course of the disease. Computed tomography has a crucial role in the assessment of pulmonary damage over time, detecting complications and monitoring treatment effects in patients with cystic fibrosis

  10. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    International Nuclear Information System (INIS)

    Smith, S.L.; Hampson, F.; Duxbury, M.; Rae, D.M.; Sinclair, M.T.

    2008-01-01

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications

  11. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  12. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  13. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  14. Extensive tumor thrombus of hepatocellular carcinoma in the entire portal venous system detected on fluorodeoxyglucose positron emission tomography computed tomography

    International Nuclear Information System (INIS)

    Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Puranik, Ameya; Rangarajan, Venkatesh

    2013-01-01

    Detection of thrombus is usually an incidental finding on fluorodeoxyglucose positron emission tomography/computed tomography studies. Nevertheless this is an important finding in terms of disease prognostication and in planning the treatment strategy. We herein report a case of a 50-years-old male, a diagnosed case of hepatocellular carcinoma with extensive hypermetabolic thrombus involving the entire portal venous system. (author)

  15. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research.

    Science.gov (United States)

    Bornstein, Michael M; Horner, Keith; Jacobs, Reinhilde

    2017-02-01

    Diagnostic radiology is an essential component of treatment planning in the field of implant dentistry. This narrative review will present current concepts for the use of cone beam computed tomography imaging, before and after implant placement, in daily clinical practice and research. Guidelines for the selection of three-dimensional imaging will be discussed, and limitations will be highlighted. Current concepts of radiation dose optimization, including novel imaging modalities using low-dose protocols, will be presented. For preoperative cross-sectional imaging, data are still not available which demonstrate that cone beam computed tomography results in fewer intraoperative complications such as nerve damage or bleeding incidents, or that implants inserted using preoperative cone beam computed tomography data sets for planning purposes will exhibit higher survival or success rates. The use of cone beam computed tomography following the insertion of dental implants should be restricted to specific postoperative complications, such as damage of neurovascular structures or postoperative infections in relation to the maxillary sinus. Regarding peri-implantitis, the diagnosis and severity of the disease should be evaluated primarily based on clinical parameters and on radiological findings based on periapical radiographs (two dimensional). The use of cone beam computed tomography scans in clinical research might not yield any evident beneficial effect for the patient included. As many of the cone beam computed tomography scans performed for research have no direct therapeutic consequence, dose optimization measures should be implemented by using appropriate exposure parameters and by reducing the field of view to the actual region of interest. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Brain computed tomography of patients with HIV/AIDS before the ...

    African Journals Online (AJOL)

    Background: The objective is to study intracranial complications of HIV/AIDS using brain‑computed tomography in patients who presented with neurological features before the advent of subsidized HIV/AIDS treatment program with highly active antiretroviral therapy (HAART) in Nigeria. Materials and Methods: Retrospective ...

  17. Recurrent proliferating trichilemmal tumor with malignant change on the f-18 fluorodeoxyglucose position emission tomography/computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Eun Ha; Kim, Eun Ha; Kim, Young Jun; Yoo, Seol Bong; Nam, Kyung Hwa [Presbyterian Medical Center, Seonam University College of Medicine, Jeonju (Korea, Republic of)

    2016-06-15

    F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography scan has been used for the diagnosis, assessment of treatment response, and follow-up of various neoplasms. Proliferating trichilemmal cyst or tumor (PTT) is a rare neoplasm, originated from the outer root sheath of a hair follicle. Because this tumor has unpredictable biological and clinical behavior, the long-term clinical follow-up is necessary to detect metastasis or recurrence. We reported a case of recurrent malignant PTT on scalp that showed increased FDG uptake.

  18. Skull base osteomyelitis in otitis externa: The utility of triphasic and single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Gupta, Ashok Kumar; Panda, Naresh Kumar; Das, Ashim; Mittal, Bhagwant Rai

    2013-01-01

    Skull base osteomyelitis (SBO) refers to infection that has spread beyond the external auditory canal to the base of the skull in advanced stages of otitis externa. Clinically, it may be difficult to differentiate SBO from severe otitis externa without bony involvement. This study was performed to determine the role of three phase bone scintigraphy (TPBS) and single photon emission tomography/computed tomography (SPECT/CT) in detecting SBO. We retrospectively analyzed records of 20 patients (14 M, 6 F) with otitis externa and suspected SBO. TPBS and SPECT/CT of the skull were performed. Findings were correlated with clinical, laboratory and diagnostic CT scan findings. All patients were diabetic with elevated erythrocyte sedimentation rate. A total of 18 patients had bilateral and two unilateral symptoms. Cranial nerves were involved in eight patients and microbiological culture of ear discharge fluid positive in seven. Early images showed increased temporal vascularity in nine patients and increased soft-tissue uptake in 10, while delayed images showed increased bone uptake in 19/20 patients. Localized abnormal tracer uptake was shown by SPECT/CT in the mastoid temporal (15), petrous (11), sphenoid (3) and zygomatic (1) and showed destructive changes in five. Thus, TPBS was found positive for SBO in 10/20 patients and changed the management in four. Our study suggests that TPBS with SPECT/CT is a useful non-invasive investigation for detection of SBO in otitis externa

  19. A computer-aided system for automatic extraction of femur neck trabecular bone architecture using isotropic volume construction from clinical hip computed tomography images.

    Science.gov (United States)

    Vivekanandhan, Sapthagirivasan; Subramaniam, Janarthanam; Mariamichael, Anburajan

    2016-10-01

    Hip fractures due to osteoporosis are increasing progressively across the globe. It is also difficult for those fractured patients to undergo dual-energy X-ray absorptiometry scans due to its complicated protocol and its associated cost. The utilisation of computed tomography for the fracture treatment has become common in the clinical practice. It would be helpful for orthopaedic clinicians, if they could get some additional information related to bone strength for better treatment planning. The aim of our study was to develop an automated system to segment the femoral neck region, extract the cortical and trabecular bone parameters, and assess the bone strength using an isotropic volume construction from clinical computed tomography images. The right hip computed tomography and right femur dual-energy X-ray absorptiometry measurements were taken from 50 south-Indian females aged 30-80 years. Each computed tomography image volume was re-constructed to form isotropic volumes. An automated system by incorporating active contour models was used to segment the neck region. A minimum distance boundary method was applied to isolate the cortical and trabecular bone components. The trabecular bone was enhanced and segmented using trabecular enrichment approach. The cortical and trabecular bone features were extracted and statistically compared with dual-energy X-ray absorptiometry measured femur neck bone mineral density. The extracted bone measures demonstrated a significant correlation with neck bone mineral density (r > 0.7, p computed tomography images scanned with low dose could eventually be helpful in osteoporosis diagnosis and its treatment planning. © IMechE 2016.

  20. Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; d'Amore, Francesco; Mylam, Karen Juul

    2012-01-01

    PURPOSETo investigate whether bone marrow biopsy (BMB) adds useful information to [(18)F]fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) staging in patients with Hodgkin lymphoma (HL). PATIENTS AND METHODSNewly diagnosed patients with HL undergoing a pretherapeu...

  1. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  2. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Moraes, Everton; Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase; Gazzoni, Fernando; Lopes, Luis Felipe Dias

    2007-01-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  3. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  4. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  6. Comparison of Tissue Density in Hounsfield Units in Computed Tomography and Cone Beam Computed Tomography.

    Science.gov (United States)

    Varshowsaz, Masoud; Goorang, Sepideh; Ehsani, Sara; Azizi, Zeynab; Rahimian, Sepideh

    2016-03-01

    Bone quality and quantity assessment is one of the most important steps in implant treatment planning. Different methods such as computed tomography (CT) and recently suggested cone beam computed tomography (CBCT) with lower radiation dose and less time and cost are used for bone density assessment. This in vitro study aimed to compare the tissue density values in Hounsfield units (HUs) in CBCT and CT scans of different tissue phantoms with two different thicknesses, two different image acquisition settings and in three locations in the phantoms. Four different tissue phantoms namely hard tissue, soft tissue, air and water were scanned by three different CBCT and a CT system in two thicknesses (full and half) and two image acquisition settings (high and low kVp and mA). The images were analyzed at three sites (middle, periphery and intermediate) using eFilm software. The difference in density values was analyzed by ANOVA and correction coefficient test (P<0.05). There was a significant difference between density values in CBCT and CT scans in most situations, and CBCT values were not similar to CT values in any of the phantoms in different thicknesses and acquisition parameters or the three different sites. The correction coefficients confirmed the results. CBCT is not reliable for tissue density assessment. The results were not affected by changes in thickness, acquisition parameters or locations.

  7. Accuracy of a computed tomography scanning procedure to manufacture digital models.

    NARCIS (Netherlands)

    Darroudi, A.M.; Kuijpers-Jagtman, A.M.; Ongkosuwito, E.M.; Suttorp, C.M.; Bronkhorst, E.M.; Breuning, K.H.

    2017-01-01

    INTRODUCTION: Accurate articulation of the digital dental casts is crucial in orthodontic diagnosis and treatment planning. We aimed to determine the accuracy of manufacturing digital dental casts from computed tomography scanning of plaster casts regarding linear dimensions and interarch

  8. Comparison of Real-Time Intraoperative Ultrasound-Based Dosimetry With Postoperative Computed Tomography-Based Dosimetry for Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Shi Peipei; Liu Bingren; Gupta, Nilendu; Bahnson, Robert R.; Wang, Jian Z.

    2008-01-01

    Purpose: To evaluate whether real-time intraoperative ultrasound (US)-based dosimetry can replace conventional postoperative computed tomography (CT)-based dosimetry in prostate brachytherapy. Methods and Materials: Between December 2001 and November 2002, 82 patients underwent 103 Pd prostate brachytherapy. An interplant treatment planning system was used for real-time intraoperative transrectal US-guided treatment planning. The dose distribution was updated according to the estimated seed position to obtain the dose-volume histograms. Postoperative CT-based dosimetry was performed a few hours later using the Theraplan-Plus treatment planning system. The dosimetric parameters obtained from the two imaging modalities were compared. Results: The results of this study revealed correlations between the US- and CT-based dosimetry. However, large variations were found in the implant-quality parameters of the two modalities, including the doses covering 100%, 90%, and 80% of the prostate volume and prostate volumes covered by 100%, 150%, and 200% of the prescription dose. The mean relative difference was 38% and 16% for doses covering 100% and 90% of the prostate volume and 10% and 21% for prostate volumes covered by 100% and 150% of the prescription dose, respectively. The CT-based volume covered by 200% of the prescription dose was about 30% greater than the US-based one. Compared with CT-based dosimetry, US-based dosimetry significantly underestimated the dose to normal organs, especially for the rectum. The average US-based maximal dose and volume covered by 100% of the prescription dose for the rectum was 72 Gy and 0.01 cm 3 , respectively, much lower than the 159 Gy and 0.65 cm 3 obtained using CT-based dosimetry. Conclusion: Although dosimetry using intraoperative US-based planning provides preliminary real-time information, it does not accurately reflect the postoperative CT-based dosimetry. Until studies have determined whether US-based dosimetry or

  9. GEANT4 simulations for Proton computed tomography applications

    International Nuclear Information System (INIS)

    Yevseyeva, Olga; Assis, Joaquim T. de; Evseev, Ivan; Schelin, Hugo R.; Shtejer Diaz, Katherin; Lopes, Ricardo T.

    2011-01-01

    Proton radiation therapy is a highly precise form of cancer treatment. In existing proton treatment centers, dose calculations are performed based on X-ray computed tomography (CT). Alternatively, one could image the tumor directly with proton CT (pCT). Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the general case on the accuracy of results obtained for the proton interaction with thick absorbers. GEANT4 simulations of proton energy spectra after passing thick absorbers do not agree well with existing experimental data, as showed previously. The spectra simulated for the Bethe-Bloch domain showed an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 version 8.2 during our simulations for pCT. This work describes in more details the simulations of the proton passage through gold absorbers with varied thickness. The simulations were done by modifying only the geometry in the Hadron therapy Example, and for all available choices of the Electromagnetic Physics Models. As the most probable reasons for these effects is some specific feature in the code or some specific implicit parameters in the GEANT4 manual, we continued our study with version 9.2 of the code. Some improvements in comparison with our previous results were obtained. The simulations were performed considering further applications for pCT development. The authors want to thank CNPq, CAPES and 'Fundacao Araucaria' for financial support of this work. (Author)

  10. Design and analysis of a tendon-based computed tomography-compatible robot with remote center of motion for lung biopsy.

    Science.gov (United States)

    Yang, Yunpeng; Jiang, Shan; Yang, Zhiyong; Yuan, Wei; Dou, Huaisu; Wang, Wei; Zhang, Daguang; Bian, Yuan

    2017-04-01

    Nowadays, biopsy is a decisive method of lung cancer diagnosis, whereas lung biopsy is time-consuming, complex and inaccurate. So a computed tomography-compatible robot for rapid and precise lung biopsy is developed in this article. According to the actual operation process, the robot is divided into two modules: 4-degree-of-freedom position module for location of puncture point is appropriate for patient's almost all positions and 3-degree-of-freedom tendon-based orientation module with remote center of motion is compact and computed tomography-compatible to orientate and insert needle automatically inside computed tomography bore. The workspace of the robot surrounds patient's thorax, and the needle tip forms a cone under patient's skin. A new error model of the robot based on screw theory is proposed in view of structure error and actuation error, which are regarded as screw motions. Simulation is carried out to verify the precision of the error model contrasted with compensation via inverse kinematics. The results of insertion experiment on specific phantom prove the feasibility of the robot with mean error of 1.373 mm in laboratory environment, which is accurate enough to replace manual operation.

  11. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  12. 123I-IMP single photon emission computed tomography (SPECT) study in childhood epilepsy

    International Nuclear Information System (INIS)

    Hara, Masafumi; Shimomura, Osamu; Kojima, Akihiro; Izunaga, Hiroshi; Tomiguchi, Seiji; Hirota, Yoshihisa; Taku, Keiichi; Miike, Teruhisa; Takahashi, Mutsumasa

    1990-01-01

    N-isopropyl-p[ 123 I]-iodoamphetamine (IMP) single photon emission computed tomography (SPECT), X-ray computed tomography (X-CT) and magnetic resonance imaging (MRI) were performed in 18 children with idiopathic seizures. In children with idiopathic seizures SPECT identified abnormal lesions in the highest rate (50%) compared with X-CT (11%) and MRI (13%), but the findings of SPECT poorly correlated with the foci on electroencephalography (EEG). Idiopathic epilepsy with abnormal uptake on SPECT was refractory to medical treatments and frequently associated with mental and/or developmental retardation. Perfusion defects identified on SPECT probably influenced the development of the brains in children. IMP SPECT is useful in the diagnosis and medical treatment in children with seizures. (author)

  13. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  14. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  15. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  16. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  17. Computer tomography in complex diagnosis of laryngeal cancer

    International Nuclear Information System (INIS)

    Savin, A.A.

    1999-01-01

    To specify the role of computer tomography in the diagnosis of malignant of the larynx. Forty-two patients with suspected laryngeal tumors were examined: 38 men and 4 women aged 41-68 years. X-ray examinations included traditional immediate tomography of the larynx. Main X-ray and computer tomographic symptoms of laryngeal tumors of different localizations are described. It is shown that the use of computer tomography in complex diagnosis of laryngeal cancer permits an objective assessment of the tumor, its structure and dissemination, and of the regional lymph nodes [ru

  18. Computed Tomography Observer Agreement in Staging Malignant Lymphoma

    NARCIS (Netherlands)

    de Jong, Antoinette; Kwee, Thomas C.; Quarles van Ufford, Henriëtte M. E.; Beek, Frederik J. A.; Quekel, Lorentz G. B. A.; de Klerk, John M. H.; Zijlstra, Josée M.; Fijnheer, Rob; Ludwig, Inge; Kersten, Marie José; Stoker, Jaap; Nievelstein, Rutger A. J.

    2016-01-01

    To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann

  19. [(18)F]Fluorodeoxyglucose - positron emission tomography/computed tomography improves staging in patients with high-risk muscle-invasive bladder cancer scheduled for radical cystectomy.

    Science.gov (United States)

    Kollberg, Petter; Almquist, Helen; Bläckberg, Mats; Cronberg, Carin; Garpered, Sabine; Gudjonsson, Sigurdur; Kleist, Jakob; Lyttkens, Kerstin; Patschan, Oliver; Liedberg, Fredrik

    2015-01-01

    The aim of this study was to evaluate the clinical use of [(18)F]fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) in addition to conventional preoperative radiological investigations in a defined group of patients with high-risk muscle-invasive bladder cancer. In total, 103 patients with high-risk muscle-invasive bladder cancer defined as stage T3/T4 disease or as stage T2 with hydronephrosis or high-risk histological features, who were provisionally scheduled to undergo cystectomy, were prospectively recruited to the study. The patients were referred to FDG-PET/CT in addition to standard preoperative investigation with computed tomography (CT). The final treatment decision was reached at a multidisciplinary conference based on all available information including the FDG-PET/CT findings. Compared to CT alone, FDG-PET/CT provided more supplemental findings suggesting malignant manifestations in 48 (47%) of the 103 patients. The additional FDG-PET/CT findings led to an altered provisional treatment plan in 28 out of 103 patients (27%), detection of disseminated bladder cancer and subsequent cancellation of the initially intended cystectomy in 16 patients, and identification of disseminated disease and treatment with induction chemotherapy before radical cystectomy in 12 patients. Preoperative FDG-PET/CT changed the treatment plan for a considerable proportion (27%) of the present patients. Accordingly, such examination can potentially improve the preoperative staging of cystectomy patients with high-risk features, and may also reduce the number of futile operations in patients with advanced disease who are beyond cure.

  20. Evaluation of valvular heart diseases with computed tomography

    International Nuclear Information System (INIS)

    Tomoda, Haruo; Hoshiai, Mitsumoto; Matsuyama, Seiya

    1982-01-01

    Forty-two patients with valvular heart diseases were studied with a third-generation computed tomographic system. The cardiac chambers (the atria and ventricles) were evaluated semiquantitatively, and valvular calcification was easily detected with computed tomography. Computed tomography was most valuable in revealing left atrial thrombi which were not identified by other diagnostic procedures in some cases. (author)

  1. Cyst-based measurements for assessing lymphangioleiomyomatosis in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lo, P., E-mail: pechinlo@mednet.edu.ucla; Brown, M. S.; Kim, H.; Kim, H.; Goldin, J. G. [Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California 90024 (United States); Argula, R.; Strange, C. [Division of Pulmonary and Critical Care Medicine, Medical University of South Carolina, Charleston, South Carolina 29425 (United States)

    2015-05-15

    Purpose: To investigate the efficacy of a new family of measurements made on individual pulmonary cysts extracted from computed tomography (CT) for assessing the severity of lymphangioleiomyomatosis (LAM). Methods: CT images were analyzed using thresholding to identify a cystic region of interest from chest CT of LAM patients. Individual cysts were then extracted from the cystic region by the watershed algorithm, which separates individual cysts based on subtle edges within the cystic regions. A family of measurements were then computed, which quantify the amount, distribution, and boundary appearance of the cysts. Sequential floating feature selection was used to select a small subset of features for quantification of the severity of LAM. Adjusted R{sup 2} from multiple linear regression and R{sup 2} from linear regression against measurements from spirometry were used to compare the performance of our proposed measurements with currently used density based CT measurements in the literature, namely, the relative area measure and the D measure. Results: Volumetric CT data, performed at total lung capacity and residual volume, from a total of 49 subjects enrolled in the MILES trial were used in our study. Our proposed measures had adjusted R{sup 2} ranging from 0.42 to 0.59 when regressing against the spirometry measures, with p < 0.05. For previously used density based CT measurements in the literature, the best R{sup 2} was 0.46 (for only one instance), with the majority being lower than 0.3 or p > 0.05. Conclusions: The proposed family of CT-based cyst measurements have better correlation with spirometric measures than previously used density based CT measurements. They show potential as a sensitive tool for quantitatively assessing the severity of LAM.

  2. Comparative study between computed tomography and bronchoscopy in the diagnosis of lung cancer

    International Nuclear Information System (INIS)

    Oliveira, Christopher; Saraiva, Antonio

    2010-01-01

    Objective: to analyze the role of computed tomography and bronchoscopy in the diagnosis of lung cancer, evaluating the effectiveness of these techniques in the presence of this disease. Parameters such as age, gender, smoking habits, histological types, staging and treatment were also analyzed. Materials and methods: the sample of the present study included 70 patients assisted at the Department of Pneumology of Hospital Distrital da Figueira da Foz, Coimbra, Portugal, who were submitted to both diagnostic methods, namely, computed tomography and bronchoscopy, to confirm the presence or the absence of lung cancer. Results: thirty-seven patients (23 men and 14 women) were diagnosed with lung cancer. Histologically 40.54% were adenocarcinoma, followed by squamous carcinoma (32.43% cases) and small-cell lung cancer (18.92%). Staging showed 6.70% stage IB disease, 23.30% stage IIIA and 36.70% stage IIIB, and 33.30% stage IV. Chemotherapy alone was the first treatment of choice for 75.7% of patients. Bronchoscopy sensitivity was 83.8%, specificity 81.8%, and accuracy 82.8%. Computed tomography sensitivity was 81.1%, specificity 63.6%, and accuracy 72.8%. Conclusion: bronchoscopy results corroborated the relevance of the method in the diagnosis of lung cancer, considering its dependence on the anatomopathological study of tissue or cells obtained through different biopsy techniques. Computed tomography presented good sensitivity (81.1%), however the specificity of only 63.6% is related to the rate of false-positive results (36.4%). (author)

  3. Comparative study between computed tomography and bronchoscopy in the diagnosis of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Christopher; Saraiva, Antonio, E-mail: asaraiva@estescoimbra.p [Escola Superior de Tecnologia da Saude de Coimbra (ESTeSC), Coimbra (Portugal)

    2010-07-15

    Objective: to analyze the role of computed tomography and bronchoscopy in the diagnosis of lung cancer, evaluating the effectiveness of these techniques in the presence of this disease. Parameters such as age, gender, smoking habits, histological types, staging and treatment were also analyzed. Materials and methods: the sample of the present study included 70 patients assisted at the Department of Pneumology of Hospital Distrital da Figueira da Foz, Coimbra, Portugal, who were submitted to both diagnostic methods, namely, computed tomography and bronchoscopy, to confirm the presence or the absence of lung cancer. Results: thirty-seven patients (23 men and 14 women) were diagnosed with lung cancer. Histologically 40.54% were adenocarcinoma, followed by squamous carcinoma (32.43% cases) and small-cell lung cancer (18.92%). Staging showed 6.70% stage IB disease, 23.30% stage IIIA and 36.70% stage IIIB, and 33.30% stage IV. Chemotherapy alone was the first treatment of choice for 75.7% of patients. Bronchoscopy sensitivity was 83.8%, specificity 81.8%, and accuracy 82.8%. Computed tomography sensitivity was 81.1%, specificity 63.6%, and accuracy 72.8%. Conclusion: bronchoscopy results corroborated the relevance of the method in the diagnosis of lung cancer, considering its dependence on the anatomopathological study of tissue or cells obtained through different biopsy techniques. Computed tomography presented good sensitivity (81.1%), however the specificity of only 63.6% is related to the rate of false-positive results (36.4%). (author)

  4. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  5. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  6. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  7. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  8. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  15. Outcomes of Modestly Hypofractionated Radiation for Lung Tumors: Pre- and Mid-Treatment Positron Emission Tomography-Computed Tomography Metrics as Prognostic Factors.

    Science.gov (United States)

    Harris, Jeremy P; Chang-Halpenny, Christine N; Maxim, Peter G; Quon, Andrew; Graves, Edward E; Diehn, Maximilian; Loo, Billy W

    2015-11-01

    Many patients with lung tumors have tumors too large for stereotactic ablative radiotherapy and comorbidities precluding concurrent chemotherapy. We report the outcomes of 29 patients treated with hypofractionated radiotherapy (RT) to 60 to 66 Gy in 3-Gy fractions. We also report an exploratory analysis of the prognostic value of the pre- and mid-RT positron emission tomography-computed tomography. Modestly hypofractionated radiation therapy (HypoRT; 60-66 Gy in 3-Gy fractions) allows patients with locally advanced thoracic tumors and poor performance status to complete treatment within a shorter period without concurrent chemotherapy. We evaluated the outcomes and imaging prognostic factors of HypoRT. We retrospectively reviewed the data from all patients with primary and metastatic intrathoracic tumors treated with HypoRT from 2006 to 2012. We analyzed the survival and toxicity outcomes, including overall survival (OS), progression-free survival (PFS), local recurrence (LR), and distant metastasis. We also evaluated the following tumor metrics in an exploratory analysis: gross tumor volume (GTV), maximum standardized uptake value (SUVMax), and metabolic tumor volume using a threshold of ≥ 50% of the SUVMax (MTV50%) or the maximum gradient of fluorine-18 fluorodeoxyglucose uptake (MTVEdge). We assessed the association of these metrics and their changes from before to mid-RT using positron emission tomography-computed tomography (PET-CT) with OS and PFS. We identified 29 patients, all with pre-RT and 20 with mid-RT PET-CT scans. The median follow-up period was 15 months. The 2-year overall and non-small-cell lung cancer-only rate for OS, PFS, and LR, was 59% and 59%, 52% and 41%, and 27% and 32%, respectively. No grade ≥ 3 toxicities developed. The median decrease in GTV, SUVMax, and MTVEdge was 11%, 24%, and 18%, respectively. Inferior OS was associated with a larger pre-RT MTVEdge (P = .005) and pre-RT MTV50% (P = .007). Inferior PFS was associated with a

  16. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Marchiori, Edson; Oliveira, Hugo

    2010-01-01

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  17. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  18. The Impact of Computed Tomography on Decision Making in Tibial Plateau Fractures.

    Science.gov (United States)

    Castiglia, Marcello Teixeira; Nogueira-Barbosa, Marcello Henrique; Messias, Andre Marcio Vieira; Salim, Rodrigo; Fogagnolo, Fabricio; Schatzker, Joseph; Kfuri, Mauricio

    2018-02-14

    Schatzker introduced one of the most used classification systems for tibial plateau fractures, based on plain radiographs. Computed tomography brought to attention the importance of coronal plane-oriented fractures. The goal of our study was to determine if the addition of computed tomography would affect the decision making of surgeons who usually use the Schatzker classification to assess tibial plateau fractures. Image studies of 70 patients who sustained tibial plateau fractures were uploaded to a dedicated homepage. Every patient was linked to a folder which contained two radiographic projections (anteroposterior and lateral), three interactive videos of computed tomography (axial, sagittal, and coronal), and eight pictures depicting tridimensional reconstructions of the tibial plateau. Ten attending orthopaedic surgeons, who were blinded to the cases, were granted access to the homepage and assessed each set of images in two different rounds, separated to each other by an interval of 2 weeks. Each case was evaluated in three steps, where surgeons had access, respectively to radiographs, two-dimensional videos of computed tomography, and three-dimensional reconstruction images. After every step, surgeons were asked to present how would they classify the case using the Schatzker system and which surgical approaches would be appropriate. We evaluated the inter- and intraobserver reliability of the Schatzker classification using the Kappa concordance coefficient, as well as the impact of computed tomography in the decision making regarding the surgical approach for each case, by using the chi-square test and likelihood ratio. The interobserver concordance kappa coefficients after each assessment step were, respectively, 0.58, 0.62, and 0.64. For the intraobserver analysis, the coefficients were, respectively, 0.76, 0.75, and 0.78. Computed tomography changed the surgical approach selection for the types II, V, and VI of Schatzker ( p  < 0.01). The addition of

  19. The transesophageal echocardiography simulator based on computed tomography images.

    Science.gov (United States)

    Piórkowski, Adam; Kempny, Aleksander

    2013-02-01

    Simulators are a new tool in education in many fields, including medicine, where they greatly improve familiarity with medical procedures, reduce costs, and, importantly, cause no harm to patients. This is so in the case of transesophageal echocardiography (TEE), in which the use of a simulator facilitates spatial orientation and helps in case studies. The aim of the project described in this paper is to simulate an examination by TEE. This research makes use of available computed tomography data to simulate the corresponding echocardiographic view. This paper describes the essential characteristics that distinguish these two modalities and the key principles of the wave phenomena that should be considered in the simulation process, taking into account the conditions specific to the echocardiography. The construction of the CT2TEE (Web-based TEE simulator) is also presented. The considerations include ray-tracing and ray-casting techniques in the context of ultrasound beam and artifact simulation. An important aspect of the interaction with the user is raised.

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  1. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  2. Preoperative lymph-node staging of invasive urothelial bladder cancer with 18F-fluorodeoxyglucose positron emission tomography/computed axial tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jensen, Thor Knak; Holt, Per; Gerke, Oke

    2011-01-01

    OBJECTIVE: The treatment and prognosis of bladder cancer are based on the depth of primary tumour invasion and the presence of metastases. A highly accurate preoperative tumour, node, metastasis (TNM) staging is critical to proper patient management and treatment. This study retrospectively...... investigated the value of ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed axial tomography (¹⁸F-FDG PET/CT) and magnetic resonance imaging (MRI) for preoperative N staging of bladder cancer. Material and methods. From June 2006 to January 2008, 48 consecutive patients diagnosed with bladder......) for MRI and ¹⁸F-FDG PET/CT, respectively. The differences in specificity and negative predictive values were not statistically significant. Conclusions. No significant statistical difference between ¹⁸F-FDG PET/CT and MRI for preoperative N staging of urothelial bladder cancer was found in the study...

  3. Cone Beam Computed Tomography-Dawn of A New Imaging Modality in Orthodontics

    Science.gov (United States)

    Mamatha, J; Chaitra, K R; Paul, Renji K; George, Merin; Anitha, J; Khanna, Bharti

    2015-01-01

    Today, we are in a world of innovations, and there are various diagnostics aids that help to take a decision regarding treatment in a well-planned way. Cone beam computed tomography (CBCT) has been a vital tool for imaging diagnostic tool in orthodontics. This article reviews case reports during orthodontic treatment and importance of CBCT during the treatment evaluation. PMID:26225116

  4. Attenuation properties and percentage depth dose of tannin-based Rhizophora spp. particleboard phantoms using computed tomography (CT) and treatment planning system (TPS) at high energy x-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Yusof, M. F. Mohd, E-mail: mfahmi@usm.my [School of Physics, Universiti Sains Malaysia, 11800 Penang (Malaysia); School of Health Sciences, Universiti Sains Malaysia, 16150 Kota Bharu, Kelantan (Malaysia); Abdullah, R. [School of Health Sciences, Universiti Sains Malaysia, 16150 Kota Bharu, Kelantan (Malaysia); Tajuddin, A. A. [School of Physics, Universiti Sains Malaysia, 11800 Penang (Malaysia); Advanced Medical and Dental Institute, Universiti Sains Malaysia, 13200 Kepala Batas, Penang (Malaysia); Hashim, R. [School of Industrial Technologies, Universiti Sains Malaysia, 11800 Penang (Malaysia); Bauk, S. [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 Penang (Malaysia)

    2016-01-22

    A set of tannin-based Rhizophora spp. particleboard phantoms with dimension of 30 cm x 30 cm was fabricated at target density of 1.0 g/cm{sup 3}. The mass attenuation coefficient of the phantom was measured using {sup 60}Co gamma source. The phantoms were scanned using Computed Tomography (CT) scanner and the percentage depth dose (PDD) of the phantom was calculated using treatment planning system (TPS) at 6 MV and 10 MV x-ray and compared to that in solid water phantoms. The result showed that the mass attenuation coefficient of tannin-based Rhizohora spp. phantoms was near to the value of water with χ{sup 2} value of 1.2. The measured PDD also showed good agreement with solid water phantom at both 6 MV and 10 MV x-ray with percentage deviation below 8% at depth beyond the maximum dose, Z{sub max}.

  5. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  6. Positron emission tomography/computed tomography and radioimmunotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Capala, Jacek; Oehr, Peter

    2009-01-01

    of a number of diagnostic and therapeutic strategies. J591, a monoclonal antibody, which targets the extracellular domain of prostate-specific membrane antigen, shows promising results. HER2 receptors may also have a potential as target for PET/CT imaging and RIT of advanced prostate cancer. SUMMARY: PET......PURPOSE OF REVIEW: Traditional morphologically based imaging modalities are now being complemented by positron emission tomography (PET)/computed tomography (CT) in prostate cancer. Metastatic prostate cancer is an attractive target for radioimmunotherapy (RIT) as no effective therapies...... are available. This review highlights the most important achievements within the last year in PET/CT and RIT of prostate cancer. RECENT FINDINGS: Conflicting results exist on the use of choline for detection of malignant disease in the prostate gland. The role of PET/CT in N-staging remains to be elucidated...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  8. Data on analysis of coronary atherosclerosis on computed tomography and 18F-sodium fluoride positron emission tomography

    Directory of Open Access Journals (Sweden)

    Toshiro Kitagawa

    2017-08-01

    Full Text Available This article contains the data showing illustrative examples of plaque classification on coronary computed tomography angiography (CCTA and measurement of 18F-sodium fluoride (18F-NaF uptake in coronary atherosclerotic lesions on positron emission tomography (PET. We divided the lesions into one of three plaque types on CCTA (calcified plaque, non-calcified plaque, partially calcified plaque. Focal 18F-NaF uptake of each lesion was quantified using maximum tissue-to-background ratio. This article also provides a representative case with a non-calcified coronary plaque detected on CCTA and identified on 18F-NaF PET/non-contrast computed tomography based on a location of a vessel branch as a landmark. These complement the data reported by Kitagawa et al. (2017 [1].

  9. Quantitative image analysis of vertebral body architecture - improved diagnosis in osteoporosis based on high-resolution computed tomography

    International Nuclear Information System (INIS)

    Mundinger, A.; Wiesmeier, B.; Dinkel, E.; Helwig, A.; Beck, A.; Schulte Moenting, J.

    1993-01-01

    71 women, 64 post-menopausal, were examined by single-energy quantitative computed tomography (SEQCT) and by high-resolution computed tomography (HRCT) scans through the middle of lumbar vertebral bodies. Computer-assisted image analysis of the high-resolution images assessed trabecular morphometry of the vertebral spongiosa texture. Texture parameters differed in women with and without age-reduced bone density, and in the former group also in patients with and without vertebral fractures. Discriminating parameters were the total number, diameter and variance of trabecular and intertrabecular spaces as well as the trabecular surface (p < 0.05)). A texture index based on these statistically selected morphometric parameters identified a subgroup of patients suffering from fractures due to abnormal spongiosal architecture but with a bone mineral content not indicative for increased fracture risk. The combination of osteodensitometric and trabecular morphometry improves the diagnosis of osteoporosis and may contribute to the prediction of individual fracture risk. (author)

  10. Use of Cone Beam Computed Tomography in Endodontics

    Science.gov (United States)

    Scarfe, William C.; Levin, Martin D.; Gane, David; Farman, Allan G.

    2009-01-01

    Cone Beam Computed Tomography (CBCT) is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D) representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imaging adjunct for endodontics. PMID:20379362

  11. Imaging in hematology. Part 2: Computed tomography, magnetic resonance imaging and nuclear imaging

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    A dramatic increase of the role of imaging in diagnosis of blood diseases occurred with the development of computed tomography (CT) and magnetic resonance imaging (MRI). At present CT of the chest, abdomen, and pelvis is routinely employed in diagnostic and staging evaluation. The bone marrow may be imaged by one of several methods, including scintigraphy, CT and MRI. Nuclear imaging at diagnosis can clarify findings of uncertain significance on conventional staging and may be very useful in the setting of large masses to follow responses to therapy nad to evaluate the residual tumor in a large mass that has responded to treatment. Recent developments such as helical CT, single proton emission computed tomography (SPECT) and positron-emission tomography (PET) have continued to advance diagnosis and therapy

  12. Ceramic and polymeric dental onlays evaluated by photo-elasticity, optical coherence tomography, and micro-computed tomography

    Science.gov (United States)

    Sinescu, Cosmin; Negrutiu, Meda; Topala, Florin; Ionita, Ciprian; Negru, Radu; Fabriky, Mihai; Marcauteanu, Corina; Bradu, Adrian; Dobre, George; Marsavina, Liviu; Rominu, Mihai; Podoleanu, Adrian

    2011-10-01

    Dental onlays are restorations used to repair rear teeth that have a mild to moderate amount of decay. They can also be used to restore teeth that are cracked or fractured if the damage is not severe enough to require a dental crown. The use of onlays requires less tooth reduction than does the use of metal fillings. This allows dentists to conserve more of a patient's natural tooth structure in the treatment process. The aims of this study are to evaluate the biomechanical comportment of the dental onlays, by using the 3D photo elasticity method and to investigate the integrity of the structures and their fitting to the dental support. For this optical coherence tomography and micro-computed tomography were employed. Both methods were used to investigate 37 dental onlays, 17 integral polymeric and 20 integral ceramic. The results permit to observe materials defects inside the ceramic or polymeric onlays situate in the biomechanically tensioned areas that could lead to fracture of the prosthetic structure. Marginal fitting problems of the onlays related to the teeth preparations were presented in order to observe the possibility of secondary cavities. The resulted images from the optical coherence tomography were verified by the micro-computed tomography. In conclusion, the optical coherence tomography can be used as a clinical method in order to evaluate the integrity of the dental ceramic and polymeric onlays and to investigate the quality of the marginal fitting to the teeth preparations.

  13. Three-dimensional cone-beam computed tomography: A new approach to the diagnosis and treatment planning of impacted mandibular third molars

    International Nuclear Information System (INIS)

    Kanazirska, P.; Yordanov, G.; Angelova, I.; Kanazirski, N.

    2017-01-01

    Cone Beam Computed Tomography (CBCT) is a relatively new method in dental practice which raises a more precise diagnosis and correct treatment plan. The image of the impacted teeth and surrounding structures with CBCT are with better quality and informativity than the conventional imaging-diagnostic methods . The use of CBCT to determine the ratio of the impacted teeth to the mandibular canal is necessary for the prevention of complications associated with iatrogenic trauma to the vascular- nerve bundle. The aim of this study was to determine the anatomic relationship between the roots of impacted third molars and mandibular canal using CBCT imaging. The studied patients with impacted third molars of the mandible are 127, aged 17 through 60.They were examined with Cone-beam Computed Tomography (CBCT). From the 195 impacted third molar with the - higher frequency are those in which the channel is below their roots-107 teeth (54.9%). The second frequency are the teeth where the channel is located lingually-57 (29.2%). Follow the teeth, in which the channel has a buccal location-25 (12.8%). With the lowest frequency are cases in which the mandibular canal is between the roots of impacted teeth-6 teeth (3.1%).At 132 teeth (67.7%) mandibular canal is at a distance of 1 mm. At 63 teeth (32.3%) the channel is at a distance of over 1 mm. The high resolution cuts in different planes and three-dimensional reconstructions made substantially as set forth preferred for different specialists in dentistry. Precise measurements of the bone around the mandibular canal prevent damage to neurovascular bundle. This makes the method preferred for planning appropriate treatment. Key words: Cone Beam Computed Tomography. Impacted Third Molars. Mandibular Canal [bg

  14. Computed tomography of sacro-iliac joints

    International Nuclear Information System (INIS)

    Miquel, A.; Laredo, J.D.

    1995-01-01

    Actual technologies to explore sacro-iliac joints are conventional radiography, computed tomography , scintigraphy and nuclear magnetic resonance imaging. Standards films are sufficient, except in beginning sacro-iliac septic inflammations where the computed tomography is superior. Two problems are generally posed for the radiologist, to differentiate a septic arthritis from a rheumatic pathology An other problem in diagnosis is to make the difference between a degenerative arthropathy (which does not need a further investigation) and an infectious rheumatic pathology where more exploration is necessary. 28 refs., 3 tabs., 13 figs

  15. Applications of cone beam computed tomography for a prosthodontist.

    Science.gov (United States)

    John, George Puthenpurayil; Joy, Tatu Elenjickal; Mathew, Justin; Kumar, Vinod R B

    2016-01-01

    Cone beam computed tomography (CBCT) is a medical imaging technique of X-ray computed tomography where the X-rays are divergent, forming a cone. CBCT systems have been designed for imaging hard tissues of the maxillofacial region. The increasing availability of this technology provides the dental clinician with an imaging modality capable of providing a three-dimensional representation of the maxillofacial skeleton with minimal distortion. This article is intended to elaborate and enunciate on the various applications and benefits of CBCT, in the realm of maxillofacial prosthodontics, over and beyond its obvious benefits in the rehabilitation of patients with implants. With the onus of meticulous reconstruction of near ideal occlusion resting on the prosthodontist, CBCT provides a unique imaging option, which can be a boon in various aspects of prosthodontic practice - from imaging of the temporomandibular joint for accurate movement simulation, to template assisted maxillofacial reconstruction or even over denture therapy. CBCT could play a crucial role in lessening the burden of a hectic prosthodontic routine for the clinician and critically contribute to accurate and effective treatment for the patient. Apart from the authors' clinical experiences shared here, a web-based search for relevant articles in this specific area of interest was also conducted. The selected articles were critically reviewed and the data acquired were systematically compiled.

  16. Reproducibility in the assessment of acute pancreatitis with computed tomography

    International Nuclear Information System (INIS)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D'Ippolito, Giuseppe

    2007-01-01

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (κ). Results: Interobserver agreement was κ 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was κ = 0.796 and 0.732 for unenhanced morphological index; κ 0.725 and 0.802 for contrast- enhanced morphological index; κ = 0.674 and 0.849 for presence of pancreatic necrosis; κ = 0.606 and 0.770 for pancreatic necrosis extension; and κ = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  17. Diffuse abnormalities of the trachea: computed tomography findings

    International Nuclear Information System (INIS)

    Marchiori, Edson; Araujo Neto, Cesar de

    2008-01-01

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  18. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  19. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  20. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  1. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  2. Comparison of plain radiography, conventional tomography, and computed tomography in detecting intrathoracic lymph node metastases from lung carcinoma

    International Nuclear Information System (INIS)

    Osborne, D.R.; Korobkin, M.; Ravin, C.E.

    1982-01-01

    Forty-two patients with T2 bronchogenic carcinoma were evaluated with plain radiography, conventional 55 0 oblique hilar and anteroposterior mediastinal tomography, and computed tomography (CT) to compare their accuracy in assessing mediastinal and hilar nodal metastases. Definitive staging was achieved by thoracotomy and histopathological evaluation of resected specimens. All modalities demonstrated about the same accuracy, however, in the 25 patients with hilar and/or mediastinal lymphadenopathy, CT of the mediastinum was more sensitive but not more specific than the other two and conventional tomography was no more accurate than CT for hilar evaluation. Overall, no technicue was accurate enough for routine staging; their value may lie in directing biopsy or in treatment planning in patients with inoperable disease

  3. Computed Tomography-Enhanced Anatomy Course Using Enterprise Visualization

    Science.gov (United States)

    May, Hila; Cohen, Haim; Medlej, Bahaa; Kornreich, Liora; Peled, Nathan; Hershkovitz, Israel

    2013-01-01

    Rapid changes in medical knowledge are forcing continuous adaptation of the basic science courses in medical schools. This article discusses a three-year experience developing a new Computed Tomography (CT)-based anatomy curriculum at the Sackler School of Medicine, Tel Aviv University, including describing the motivations and reasoning for the…

  4. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  5. Intermuscular pterygoid-temporal abscess following inferior alveolar nerve block anesthesia-A computer tomography based navigated surgical intervention: Case report and review.

    Science.gov (United States)

    Wallner, Jürgen; Reinbacher, Knut Ernst; Pau, Mauro; Feichtinger, Matthias

    2014-01-01

    Inferior alveolar nerve block (IANB) anesthesia is a common local anesthetic procedure. Although IANB anesthesia is known for its safety, complications can still occur. Today immediately or delayed occurring disorders following IANB anesthesia and their treatment are well-recognized. We present a case of a patient who developed a symptomatic abscess in the pterygoid region as a result of several inferior alveolar nerve injections. Clinical symptoms included diffuse pain, reduced mouth opening and jaw's hypomobility and were persistent under a first step conservative treatment. Since image-based navigated interventions have gained in importance and are used for various procedures a navigated surgical intervention was initiated as a second step therapy. Thus precise, atraumatic surgical intervention was performed by an optical tracking system in a difficult anatomical region. A symptomatic abscess was treated by a computed tomography-based navigated surgical intervention at our department. Advantages and disadvantages of this treatment strategy are evaluated.

  6. Intermuscular pterygoid-temporal abscess following inferior alveolar nerve block anesthesia–A computer tomography based navigated surgical intervention: Case report and review

    Science.gov (United States)

    Wallner, Jürgen; Reinbacher, Knut Ernst; Pau, Mauro; Feichtinger, Matthias

    2014-01-01

    Inferior alveolar nerve block (IANB) anesthesia is a common local anesthetic procedure. Although IANB anesthesia is known for its safety, complications can still occur. Today immediately or delayed occurring disorders following IANB anesthesia and their treatment are well-recognized. We present a case of a patient who developed a symptomatic abscess in the pterygoid region as a result of several inferior alveolar nerve injections. Clinical symptoms included diffuse pain, reduced mouth opening and jaw's hypomobility and were persistent under a first step conservative treatment. Since image-based navigated interventions have gained in importance and are used for various procedures a navigated surgical intervention was initiated as a second step therapy. Thus precise, atraumatic surgical intervention was performed by an optical tracking system in a difficult anatomical region. A symptomatic abscess was treated by a computed tomography-based navigated surgical intervention at our department. Advantages and disadvantages of this treatment strategy are evaluated. PMID:24987612

  7. Sacrococcygeal chordoma: increased 99mTc methylene diphosphonate uptake on single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppuswamy; Bhattacharya, Anish; Harisankar, Chidambaram Natarajan Balasubramaniam; Mittal, Bhagwant Rai; Goni, Vijay

    2012-01-01

    Chordoma is a malignant tumor arising from the remnants of the notochord, and is the most frequent primitive tumor of the sacrum. While most sacral tumors show increased concentration of bone-seeking radiopharmaceuticals, chordomas usually exhibit decreased uptake. The authors present an image of a sacrococcygeal chordoma with osteolysis and increased uptake of 99m Tc methylene diphosphonate on planar and single photon emission computed tomography/computed tomography bone scintigraphy. (author)

  8. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  9. Simulation of computed tomography dose based on voxel phantom

    Science.gov (United States)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  10. Pulmonary malaria: high-resolution computed tomography findings - a case report

    International Nuclear Information System (INIS)

    Rodrigues, Rosana; Souza, Daniel Andrade Tinoco de; Marchiori, Edson

    2004-01-01

    We report the case of a 38-year-old man with pulmonary malaria. High-resolution computed tomography showed thickening of the peribronchovascular interstitium and interlobular septa, areas of consolidation and ground glass attenuation and bilateral pleural effusion suggesting pulmonary edema. The patient recovered well after receiving specific treatment and was discharged after 11 days of hospitalization. (author)

  11. Use of Cone Beam Computed Tomography in Endodontics

    Directory of Open Access Journals (Sweden)

    William C. Scarfe

    2009-01-01

    Full Text Available Cone Beam Computed Tomography (CBCT is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imaging adjunct for endodontics.

  12. Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography

    Science.gov (United States)

    Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2013-01-01

    OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418

  13. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  14. Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography

    Directory of Open Access Journals (Sweden)

    Yubin Liu

    2016-01-01

    Full Text Available We developed a homemade dual-modality imaging system that combines multispectral photoacoustic computed tomography and ultrasound computed tomography for reconstructing the structural and functional information of human finger joint systems. The fused multispectral photoacoustic-ultrasound computed tomography (MPAUCT system was examined by the phantom and in vivo experimental tests. The imaging results indicate that the hard tissues such as the bones and the soft tissues including the blood vessels, the tendon, the skins, and the subcutaneous tissues in the finger joints systems can be effectively recovered by using our multimodality MPAUCT system. The developed MPAUCT system is able to provide us with more comprehensive information of the human finger joints, which shows its potential for characterization and diagnosis of bone or joint diseases.

  15. Use of Respiratory-Correlated Four-Dimensional Computed Tomography to Determine Acceptable Treatment Margins for Locally Advanced Pancreatic Adenocarcinoma

    International Nuclear Information System (INIS)

    Goldstein, Seth D.; Ford, Eric C.; Duhon, Mario; McNutt, Todd; Wong, John; Herman, Joseph M.

    2010-01-01

    Purpose: Respiratory-induced excursions of locally advanced pancreatic adenocarcinoma could affect dose delivery. This study quantified tumor motion and evaluated standard treatment margins. Methods and Materials: Respiratory-correlated four-dimensional computed tomography images were obtained on 30 patients with locally advanced pancreatic adenocarcinoma; 15 of whom underwent repeat scanning before cone-down treatment. Treatment planning software was used to contour the gross tumor volume (GTV), bilateral kidneys, and biliary stent. Excursions were calculated according to the centroid of the contoured volumes. Results: The mean ± standard deviation GTV excursion in the superoinferior (SI) direction was 0.55 ± 0.23 cm; an expansion of 1.0 cm adequately accounted for the GTV motion in 97% of locally advanced pancreatic adenocarcinoma patients. Motion GTVs were generated and resulted in a 25% average volume increase compared with the static GTV. Of the 30 patients, 17 had biliary stents. The mean SI stent excursion was 0.84 ± 0.32 cm, significantly greater than the GTV motion. The xiphoid process moved an average of 0.35 ± 0.12 cm, significantly less than the GTV. The mean SI motion of the left and right kidneys was 0.65 ± 0.27 cm and 0.77 ± 0.30 cm, respectively. At repeat scanning, no significant changes were seen in the mean GTV size (p = .8) or excursion (p = .3). Conclusion: These data suggest that an asymmetric expansion of 1.0, 0.7, and 0.6 cm along the respective SI, anteroposterior, and medial-lateral directions is recommended if a respiratory-correlated four-dimensional computed tomography scan is not available to evaluate the tumor motion during treatment planning. Surrogates of tumor motion, such as biliary stents or external markers, should be used with caution.

  16. Diagnosis of lumbar disc hernia with computed tomography

    International Nuclear Information System (INIS)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru

    1982-01-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed. (Ueda, J.)

  17. Ultrasonic and computed tomography in radiotherapy planning - a comparison

    International Nuclear Information System (INIS)

    Schertel, L.

    1980-01-01

    The precondition of any radiotherapy is radiation planning. This must be done individually for every patient and must be applicable for any region of the body. Modern irradiation planning requires pictures of the body parts concerned; these can be made by means of the ultrasonic method and computed tomography. This comparative investigation leads to the result (see fig. 4 and 5) that computed tomographic body part pictures should be preferred to those made sonographically. The opinion of Huenig and Co. [8] that ultrasonic tomography will soon lose some of its importance within irradiation planning once computed tomography is introduced could be confirmed by the latest developments. The authors can confirm this also out of their own experience and agree with Winkel and Hermann [23] that computed tomography cannot be done without any more irradiation planning. (orig.) [de

  18. Non-infectious complications of continuous ambulatory peritoneal dialysis: evaluation with peritoneal computed tomography

    International Nuclear Information System (INIS)

    Camsari, T.; Celik, A.; Ozaksoy, D.; Salman, S.; Cavdar, C.; Sifil, A.

    1998-01-01

    The purpose of the study was to evaluate the non-infectious complications of continuous ambulatory peritoneal dialysis (CAPD) using peritoneal computed tomography (PCT). Twenty symptomatic patients were included in the study. Initially 2000 ml of dialysate fluid was infused into the peritoneal cavity and standard peritoneal computed cavity and standard peritoneal computed tomography (SPCT) serial scans with 10 mm thickness were performed from the mid-thoracic region to the genital organs. Afterwards, 100 ml of non-ionic contrast material containing 300 mg/ml iodine was injected through the catheter and was distributed homogeneously in the intra-abdominal dialysate fluid by changing the positions of the patients; after waiting for 2-4 h, the CT scan was repeated as peritoneal contrast computed tomography (PCCT). In patients (n = 20) both SPCT and PCCT revealed 90 % (n = 18) pathological findings. But PCCT showed 60 % (n = 12) additional pathological findings. We believe that PCT is beneficial for evaluation of non-infectious complications of CAPD. But PCCT is superior to SPCT in evaluating non-infectious complications encountered in patients on CAPD treatment. (author)

  19. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  20. Computed tomography contrast media extravasation: treatment algorithm and immediate treatment by squeezing with multiple slit incisions.

    Science.gov (United States)

    Kim, Sue Min; Cook, Kyung Hoon; Lee, Il Jae; Park, Dong Ha; Park, Myong Chul

    2017-04-01

    In our hospital, an adverse event reporting system was initiated that alerts the plastic surgery department immediately after suspecting contrast media extravasation injury. This system is particularly important for a large volume of extravasation during power injector use. Between March 2011 and May 2015, a retrospective chart review was performed on all patients experiencing contrast media extravasation while being treated at our hospital. Immediate treatment by squeezing with multiple slit incisions was conducted for a portion of these patients. Eighty cases of extravasation were reported from approximately 218 000 computed tomography scans. The expected extravasation volume was larger than 50 ml, or severe pressure was felt on the affected limb in 23 patients. They were treated with multiple slit incisions followed by squeezing. Oedema of the affected limb disappeared after 1-2 hours after treatment, and the skin incisions healed within a week. We propose a set of guidelines for the initial management of contrast media extravasation injuries for a timely intervention. For large-volume extravasation cases, immediate management with multiple slit incisions is safe and effective in reducing the swelling quickly, preventing patient discomfort and decreasing skin and soft tissue problems. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. Diagnosis of hoof diseases in horses using computed tomography

    International Nuclear Information System (INIS)

    Kovac, M.; Nowak, M.; Kaufels, N.; Tambur, Z.

    2002-01-01

    This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Bergische Tierklinik), Germany, of 39 horses with hoof diseases. The most frequently findings were the navicular syndrome (eight horses), laminitis (seven horses), keratnoma (six horses) and ossification of collateral cartilages in the distal phalanx (four horses). The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography

  2. Generation of three-dimensional prototype models based on cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, J.T.; Berndt, D.C.; Zehnder, M. [University of Basel, Department of Oral Surgery, University Hospital for Oral Surgery, Oral Radiology and Oral Medicine, Basel (Switzerland); Schumacher, R. [University of Applied Sciences Northwestern Switzerland, School of Life Sciences, Institute for Medical and Analytical Technologies, Muttenz (Switzerland)

    2009-03-15

    The purpose of this study was to generate three-dimensional models based on digital volumetric data that can be used in basic and advanced education. Four sets of digital volumetric data were established by cone beam computed tomography (CBCT) (Accuitomo, J. Morita, Kyoto, Japan). Datasets were exported as Dicom formats and imported into Mimics and Magic software programs to separate the different tissues such as nerve, tooth and bone. These data were transferred to a Polyjet 3D Printing machine (Eden 330, Object, Israel) to generate the models. Three-dimensional prototype models of certain limited anatomical structures as acquired volumetrically were fabricated. Generating three-dimensional models based on CBCT datasets is possible. Automated routine fabrication of these models, with the given infrastructure, is too time-consuming and therefore too expensive. (orig.)

  3. Generation of three-dimensional prototype models based on cone beam computed tomography

    International Nuclear Information System (INIS)

    Lambrecht, J.T.; Berndt, D.C.; Zehnder, M.; Schumacher, R.

    2009-01-01

    The purpose of this study was to generate three-dimensional models based on digital volumetric data that can be used in basic and advanced education. Four sets of digital volumetric data were established by cone beam computed tomography (CBCT) (Accuitomo, J. Morita, Kyoto, Japan). Datasets were exported as Dicom formats and imported into Mimics and Magic software programs to separate the different tissues such as nerve, tooth and bone. These data were transferred to a Polyjet 3D Printing machine (Eden 330, Object, Israel) to generate the models. Three-dimensional prototype models of certain limited anatomical structures as acquired volumetrically were fabricated. Generating three-dimensional models based on CBCT datasets is possible. Automated routine fabrication of these models, with the given infrastructure, is too time-consuming and therefore too expensive. (orig.)

  4. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  5. The role of 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography in the management of patients with carcinoma of unknown primary.

    Science.gov (United States)

    Deonarine, P; Han, S; Poon, F W; de Wet, C

    2013-08-01

    Carcinoma of unknown primary is one of the ten most frequent cancers worldwide. Its median survival time is less than 10 months. Detecting primary tumour locations and/or occult metastatic lesions may inform definitive treatment and improve patients' prognosis. We aimed to determine: (1) the sensitivity, specificity and accuracy of (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography; (2) its detection rate of primary tumour locations and occult metastases and (3) factors associated with improved survival times. We retrospectively reviewed all cases in the West of Scotland for the period 1 December 2007 to 31 May 2011 that met all our selection criteria: (1) diagnosis of carcinoma of unknown primary; (2) a thorough but negative 'work-up' and (3) (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography report. Statistical methods included frequencies, Kaplan-Meier graphs and log-rank tests to compare survival times. (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography detected primary tumour sites in 19/51 (37.3%) and occult metastases in 28/51 (54.9%) of eligible patients. Its sensitivity, specificity and accuracy were 79.2%, 70.4% and 74.5%, respectively; 20/51 (39.2%) patients died during the study period with a median survival of 8.4 months (range 21.4, SD ± 6.2). The number of metastatic locations was strongly associated with survival (p = 0.002), but detection of a primary tumour site (p = 0.174) or histopathology (p = 0.301) was not. (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography detected occult metastatic sites in the majority and a primary cancer location in a substantial minority of patients. Our results were comparable with international literature and may indicate that (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography have an early role to improve the accuracy of cancer staging and to optimise carcinoma of unknown

  6. Comparison of five segmentation tools for 18F-fluoro-deoxy-glucose-positron emission tomography-based target volume definition in head and neck cancer.

    NARCIS (Netherlands)

    Schinagl, D.A.X.; Vogel, W.V.; Hoffmann, A.L.; Dalen, J.A. van; Oyen, W.J.G.; Kaanders, J.H.A.M.

    2007-01-01

    PURPOSE: Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with (18)F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may

  7. Assessment of skull base involvement in nasopharyngeal carcinoma: comparisons of single-photon emission tomography with planar bone scintigraphy and X-ray computed tomography

    International Nuclear Information System (INIS)

    Lee Chianghsuan; Wang Peiwen; Chen Hueyong; Lui Chunchung; Su Chihying

    1995-01-01

    The diagnostic contribution of single-photon emission tomography (SPET) to the detection of bone lesions of the skull base was explored in 200 patients with nasopharyngeal carcinoma (NPC). Comparison of SPET with planar bone scintigraphy showed that SPET improved the contrast and better defined the lesions in 107 out of the 200 patients. Comparison of SPET with X-ray computed tomography (CT) showed that SPET did not miss the lesions detected by CT while CT missed 49% of the lesions detected by SPET. The only false-positive lesion with SPET was detected in the mastoid bone. SPET detected skull base lesions in all of the 35 patients with cranial nerve involvement, while CT missed eight and planar bone scintigraphy missed four. The findings suggest that SPET should be included in the routine check-up examinations of patients with NPC. (orig.)

  8. Daily Megavoltage Computed Tomography in Lung Cancer Radiotherapy: Correlation Between Volumetric Changes and Local Outcome

    International Nuclear Information System (INIS)

    Bral, Samuel; De Ridder, Mark; Duchateau, Michael; Gevaert, Thierry; Engels, Benedikt; Schallier, Denis; Storme, Guy

    2011-01-01

    Purpose: To assess the predictive or comparative value of volumetric changes, measured on daily megavoltage computed tomography during radiotherapy for lung cancer. Patients and Methods: We included 80 patients with locally advanced non-small-cell lung cancer treated with image-guided intensity-modulated radiotherapy. The radiotherapy was combined with concurrent chemotherapy, combined with induction chemotherapy, or given as primary treatment. Patients entered two parallel studies with moderately hypofractionated radiotherapy. Tumor volume contouring was done on the daily acquired images. A regression coefficient was derived from the volumetric changes on megavoltage computed tomography, and its predictive value was validated. Logarithmic or polynomial fits were applied to the intratreatment changes to compare the different treatment schedules radiobiologically. Results: Regardless of the treatment type, a high regression coefficient during radiotherapy predicted for a significantly prolonged cause-specific local progression free-survival (p = 0.05). Significant differences were found in the response during radiotherapy. The significant difference in volumetric treatment response between radiotherapy with concurrent chemotherapy and radiotherapy plus induction chemotherapy translated to a superior long-term local progression-free survival for concurrent chemotherapy (p = 0.03). An enhancement ratio of 1.3 was measured for the used platinum/taxane doublet in comparison with radiotherapy alone. Conclusion: Contouring on daily megavoltage computed tomography images during radiotherapy enabled us to predict the efficacy of a given treatment. The significant differences in volumetric response between treatment strategies makes it a possible tool for future schedule comparison.

  9. Role of single photon emission computed tomography/computed tomography in diagnostic iodine-131 scintigraphy before initial radioiodine ablation in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Agrawal, Kanhaiyalal; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2005-01-01

    The study was performed to evaluate the incremental value of single photon emission computed tomography/computed tomography (SPECT/CT) over planar radioiodine imaging before radioiodine ablation in the staging, management and stratification of risk of recurrence (ROR) in differentiated thyroid cancer (DTC) patients. Totally, 83 patients (21 male, 62 female) aged 17–75 (mean 39.9) years with DTC were included consecutively in this prospective study. They underwent postthyroidectomy planar and SPECT/CT scans after oral administration of 37–114 MBq iodine-131 (I-131). The scans were interpreted as positive, negative or suspicious for tracer uptake in the thyroid bed, cervical lymph nodes and sites outside the neck. In each case, the findings on planar images were recorded first, without knowledge of SPECT/CT findings. Operative and pathological findings were used for postsurgical tumor–node–metastasis staging. The tumor staging was reassessed after each of these two scans. Single photon emission computed tomography/computed tomography localized radioiodine uptake in the thyroid bed in 9/83 (10.8%) patients, neck nodes in 24/83 (28.9%) patients and distant metastases in 8/83 (9.6%) patients in addition to the planar study. Staging was changed in 8/83 (9.6%), ROR in 11/83 (13.2%) and management in 26/83 (31.3%) patients by the pretherapy SPECT/CT in comparison to planar imaging. SPECT/CT had incremental value in 32/83 patients (38.5%) over the planar scan. Single photon emission computed tomography/computed tomography is feasible during a diagnostic I-131 scan with a low amount of radiotracer. It improved the interpretation of pretherapy I-131 scintigraphy and changed the staging and subsequent patient management

  10. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D. [UCSF Benioff Children' s Hospital, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2014-07-15

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model-based

  11. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    International Nuclear Information System (INIS)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D.

    2014-01-01

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model-based

  12. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  13. Clinical utility of dental cone-beam computed tomography: current perspectives

    OpenAIRE

    Jaju, Prashant P; Jaju, Sushma P

    2014-01-01

    Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology an...

  14. [Computed tomography semiotics of osteonecrosis and sequestration in chronic hematogenic osteomyelitis].

    Science.gov (United States)

    D'iachkova, G V; Mitina, Iu L

    2007-01-01

    Based on the data of computed tomography, radiography and densitometry in 39 patients the authors describe in detail the signs of osteonecrosis and sequestration of different localization and extension.

  15. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  16. Cone-beam computed tomography: An inevitable investigation in cleidocranial dysplasia

    Directory of Open Access Journals (Sweden)

    Nandita S Gupta

    2015-01-01

    Full Text Available Cleidocranial dysplasia is a heritable skeletal dysplasia and one of the most common features of this syndrome is multiple impacted supernumerary teeth. Cone-beam computed tomography, the most recent advancement in maxillofacial imaging, provides the clinician to view the morphology of the skull and the dentition in all three dimensions and help in treatment planning for the patient.

  17. Simulation-based artifact correction (SBAC) for metrological computed tomography

    Science.gov (United States)

    Maier, Joscha; Leinweber, Carsten; Sawall, Stefan; Stoschus, Henning; Ballach, Frederic; Müller, Tobias; Hammer, Michael; Christoph, Ralf; Kachelrieß, Marc

    2017-06-01

    Computed tomography (CT) is a valuable tool for the metrolocical assessment of industrial components. However, the application of CT to the investigation of highly attenuating objects or multi-material components is often restricted by the presence of CT artifacts caused by beam hardening, x-ray scatter, off-focal radiation, partial volume effects or the cone-beam reconstruction itself. In order to overcome this limitation, this paper proposes an approach to calculate a correction term that compensates for the contribution of artifacts and thus enables an appropriate assessment of these components using CT. Therefore, we make use of computer simulations of the CT measurement process. Based on an appropriate model of the object, e.g. an initial reconstruction or a CAD model, two simulations are carried out. One simulation considers all physical effects that cause artifacts using dedicated analytic methods as well as Monte Carlo-based models. The other one represents an ideal CT measurement i.e. a measurement in parallel beam geometry with a monochromatic, point-like x-ray source and no x-ray scattering. Thus, the difference between these simulations is an estimate for the present artifacts and can be used to correct the acquired projection data or the corresponding CT reconstruction, respectively. The performance of the proposed approach is evaluated using simulated as well as measured data of single and multi-material components. Our approach yields CT reconstructions that are nearly free of artifacts and thereby clearly outperforms commonly used artifact reduction algorithms in terms of image quality. A comparison against tactile reference measurements demonstrates the ability of the proposed approach to increase the accuracy of the metrological assessment significantly.

  18. Evolution of Computed Tomography Findings in Secondary Aortoenteric Fistula

    International Nuclear Information System (INIS)

    Bas, Ahmet; Simsek, Osman; Kandemirli, Sedat Giray; Rafiee, Babak; Gulsen, Fatih; Numan, Furuzan

    2015-01-01

    Aortoenteric fistula is a rare but significant clinical entity associated with high morbidity and mortality if remain untreated. Clinical presentation and imaging findings may be subtle and prompt diagnosis can be difficult. Herein, we present a patient who initially presented with abdominal pain and computed tomography showed an aortic aneurysm compressing duodenum without any air bubbles. One month later, the patient presented with gastrointestinal bleeding and computed tomography revealed air bubbles within aneurysm. With a diagnosis of aortoenteric fistula, endovascular aneurysm repair was carried out. This case uniquely presented the computed tomography findings in progression of an aneurysm to an aortoenteric fistula

  19. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  20. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    International Nuclear Information System (INIS)

    Macedo, Clarissa Aguiar de; Baena, Marcos Eduardo da Silva; Uezumi, Kiyomi Kato; Castro, Claudio Campi de; Lucarelli, Claudio Luiz; Cerri, Giovanni Guido

    2008-01-01

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  1. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  2. Computed tomography in intracranial malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, S; Odake, G; Fujimoto, M; Yamaki, T; Mizukawa, N [Kyoto Prefectural Univ. of Medicine (Japan)

    1978-09-01

    Malignant lymphoma of the central nervous system has been found more and more often in recent years, partly because of the increased use of radiation and such drugs as steroids and antibiotics. However, the definite diagnosis of this disease is difficult until histological verification has been done by operation or autopsy. Since the revolutionary development of computed tomography, however, several reports have been presented, on the computed tomography of malignant lymphoma of the thorax and abdomen. Nevertheless, only a few cases of intracranial malignant lymphoma have been reported. The purpose of this paper, using four patients, is to emphasize the value of computed tomography in the diagnosis of intracranial malignant lymphoma. The characteristic CT findings of intracranial malignant lymphoma may be summarized follows: (1) the tumors are demonstrated to be well-defined, nodular-shaped, and homogenous isodensity - or slightly high-density - lesions in plain scans, and the tumors homogenously increase in density upon contrast enhancement; (2) the disease always has multifocal intracranial lesions, which are shown simultaneously or one after another, and (3) perifocal edema is prominent around the tumors in the cerebral hemisphere.

  3. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  4. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  5. Computed tomography in epidural abscess, subdural empyema, meningitis, and brain abscess

    International Nuclear Information System (INIS)

    Schadel, A.; Boettcher, H.D.; Haverkamp, U.; Wagner, W.; Schmilowski, G.M.; Muenster Univ.

    1983-01-01

    Computerised tomography cannot be of great help in diagnosing meningitis. Examination of the cerebrospinal fluid remains essential. After the inflammation of the meninges has progressed to some stage of encephalitis, the formation of an abscess can be located via computed tomography. It is characterised by the ring-type abscess capsule. Computed tomography for diagnostic purposes is superior to cerebral scanning, which demonstrates enhanced activity, but does not show the formation of a membrane, so essential for differential diagnosis. Furthermore, computed tomography shows the adjacent anatomical structures and answers the questions of displacements and threatening invasion of the ventricle system. Epidural and subdural abscesses can also be located by computed tomography. Therapy can begin directly after computerised tomography, whereas in scintigraphy only a non-specific enhanced activity is present, which often does not allow differentiation between epidural and subdural location. (orig.) [de

  6. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  7. Efficacy of navigation in skull base surgery using composite computer graphics of magnetic resonance and computed tomography images

    International Nuclear Information System (INIS)

    Hayashi, Nakamasa; Kurimoto, Masanori; Hirashima, Yutaka; Ikeda, Hiroaki; Shibata, Takashi; Tomita, Takahiro; Endo, Shunro

    2001-01-01

    The efficacy of a neurosurgical navigation system using three-dimensional composite computer graphics (CGs) of magnetic resonance (MR) and computed tomography (CT) images was evaluated in skull base surgery. Three-point transformation was used for integration of MR and CT images. MR and CT image data were obtained with three skin markers placed on the patient's scalp. Volume-rendering manipulations of the data produced three-dimensional CGs of the scalp, brain, and lesions from the MR images, and the scalp and skull from the CT. Composite CGs of the scalp, skull, brain, and lesion were created by registering the three markers on the three-dimensional rendered scalp images obtained from MR imaging and CT in the system. This system was used for 14 patients with skull base lesions. Three-point transformation using three-dimensional CGs was easily performed for multimodal registration. Simulation of surgical procedures on composite CGs aided in comprehension of the skull base anatomy and selection of the optimal approaches. Intraoperative navigation aided in determination of actual spatial position in the skull base and the optimal trajectory to the tumor during surgical procedures. (author)

  8. Pretreatment Staging Positron Emission Tomography/Computed Tomography in Patients With Inflammatory Breast Cancer Influences Radiation Treatment Field Designs

    International Nuclear Information System (INIS)

    Walker, Gary V.; Niikura, Naoki; Yang Wei; Rohren, Eric; Valero, Vicente; Woodward, Wendy A.; Alvarez, Ricardo H.; Lucci, Anthony; Ueno, Naoto T.; Buchholz, Thomas A.

    2012-01-01

    Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for staging of inflammatory breast cancer (IBC). The purpose of this study was to define how pretreatment PET/CT studies affected postmastectomy radiation treatment (PMRT) planning decisions for IBC. Methods and Materials: We performed a retrospective analysis of 62 patients diagnosed with IBC between 2004 and 2009, who were treated with PMRT in our institution and who had a staging PET/CT within 3 months of diagnosis. Patients received a baseline physical examination, staging mammography, ultrasonographic examination of breast and draining lymphatics, and chest radiography; most patients also had a bone scan (55 patients), liver imaging (52 patients), breast MRI (46 patients), and chest CT (25 patients). We compared how PET/CT findings affected PMRT, assuming that standard PMRT would target the chest wall, level III axilla, supraclavicular fossa, and internal mammary chain (IMC). Any modification of target volumes, field borders, or dose prescriptions was considered a change. Results: PET/CT detected new areas of disease in 27 of the 62 patients (44%). The areas of additional disease included the breast (1 patient), ipsilateral axilla (1 patient), ipsilateral supraclavicular (4 patients), ipsilateral infraclavicular (1 patient), ipsilateral IMC (5 patients), ipsilateral subpectoral (3 patients), mediastinal (8 patients), other distant/contralateral lymph nodes (15 patients), or bone (6 patients). One patient was found to have a non-breast second primary tumor. The findings of the PET/CT led to changes in PMRT in 11 of 62 patients (17.7%). These changes included additional fields in 5 patients, adjustment of fields in 2 patients, and higher doses to the supraclavicular fossa (2 patients) and IMC (5 patients). Conclusions: For patients with newly diagnosed IBC, pretreatment PET/CT provides important information concerning involvement of locoregional lymph nodes

  9. Computed tomography of craniomandibular osteopathy in a dog

    International Nuclear Information System (INIS)

    Hudson, J.A.; Montgomery, R.D.; Hathcock, J.T.; Jarboe, J.M.

    1994-01-01

    This report describes the use of computed tomography (CT) to evaluate the tympanic bullae and angular processes of the mandible in a West Highland White Terrier with craniomandibular osteopathy. The patient presented initially for swelling of the right forelimb. The report illustrates the use of computed tomography for evaluation of craniomandibular osteopathy, initial presentation with long-bone pathology, and remarkable resolution of osseous changes

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  12. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2014-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... examined the content, data quality, and research potential of the WDHR-CCTR. METHODS: We retrieved 2008-2012 data to examine the 1) content; 2) completeness of procedure registration using the Danish National Patient Registry as reference; 3) completeness of variable registration comparing observed vs...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  14. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  15. Positron emission tomography response criteria in solid tumours criteria for quantitative analysis of [18F]-fluorodeoxyglucose positron emission tomography with integrated computed tomography for treatment response assessment in metastasised solid tumours: All that glitters is not gold.

    Science.gov (United States)

    Willemsen, Annelieke E C A B; Vlenterie, Myrella; van Herpen, Carla M L; van Erp, Nielka P; van der Graaf, Winette T A; de Geus-Oei, Lioe-Fee; Oyen, Wim J G

    2016-03-01

    For solid tumours, quantitative analysis of [(18)F]-fluorodeoxyglucose positron emission tomography with integrated computed tomography potentially can have significant value in early response assessment and thereby discrimination between responders and non-responders at an early stage of treatment. Standardised strategies for this analysis have been proposed, and the positron emission tomography response criteria in solid tumours (PERCIST) criteria can be regarded as the current standard to perform quantitative analysis in a research setting, yet is not implemented in daily practice. However, several exceptions and limitations limit the feasibility of PERCIST criteria. In this article, we point out dilemmas that arise when applying proposed criteria like PERCIST on an expansive set of patients with metastasised solid tumours. Clinicians and scientists should be aware of these limitations to prevent that methodological issues impede successful introduction of research data into clinical practice. Therefore, to deliver on the high potential of quantitative imaging, consensus should be reached on a standardised, feasible and clinically useful analysis methodology. This methodology should be applicable in the majority of patients, tumour types and treatments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Interobserver reliability of coronoid fracture classification: two-dimensional versus three-dimensional computed tomography

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; van Dijk, Niek; Ring, David; Allan, Christopher; Anglen, Jeffrey; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Brink, Peter; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Crist, Brett; Della Rocca, Gregory; Dijkstra, Sander; Elmans, L. H. G. J.; Feibel, Roger; Flores, Luis; Frihagen, Frede; Gosens, Taco; Goslings, J. C.; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McKee, Michael; Nork, Sean; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Poolman, Rudolf; Prayson, Michael; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Thomas, George; Trumble, Tom; van Vugt, Arie; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2009-01-01

    This study tests the hypothesis that 3-dimensional computed tomography (CT) reconstructions improve interobserver agreement on classification and treatment of coronoid fractures compared with 2-dimensional CT. A total of 29 orthopedic surgeons evaluated 10 coronoid fractures on 2 occasions (first

  17. 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?

    Science.gov (United States)

    Tseng, Yolanda D.; Wootton, Landon; Nyflot, Matthew; Apisarnthanarax, Smith; Rengan, Ramesh; Bloch, Charles; Sandison, George; St. James, Sara

    2018-01-01

    Four dimensional computed tomography (4DCT) scans are routinely used in radiation therapy to determine the internal treatment volume for targets that are moving (e.g. lung tumors). The use of these studies has allowed clinicians to create target volumes based upon the motion of the tumor during the imaging study. The purpose of this work is to determine if a target volume based on a single 4DCT scan at simulation is sufficient to capture thoracic motion. Phantom studies were performed to determine expected differences between volumes contoured on 4DCT scans and those on the evaluation CT scans (slow scans). Evaluation CT scans acquired during treatment of 11 patients were compared to the 4DCT scans used for treatment planning. The images were assessed to determine if the target remained within the target volume determined during the first 4DCT scan. A total of 55 slow scans were compared to the 11 planning 4DCT scans. Small differences were observed in phantom between the 4DCT volumes and the slow scan volumes, with a maximum of 2.9%, that can be attributed to minor differences in contouring and the ability of the 4DCT scan to adequately capture motion at the apex and base of the motion trajectory. Larger differences were observed in the patients studied, up to a maximum volume difference of 33.4%. These results demonstrate that a single 4DCT scan is not adequate to capture all thoracic motion throughout treatment.

  18. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  19. Computed tomography of the traumatized abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki [Wallace Memotial Baptist Hospital, Pusan (Korea, Republic of)

    1989-02-15

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries.

  20. Computed tomography of the traumatized abdomen

    International Nuclear Information System (INIS)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki

    1989-01-01

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries

  1. Bosniak classification of renal cystic lesions according to multidetector computed tomography findings

    International Nuclear Information System (INIS)

    Miranda, Christiana Maia Nobre Rocha de; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Rocha, Milzi Sarmento da; Maranhao, Carol Pontes de Miranda; Santos, Carla Jotta Justo dos

    2014-01-01

    Renal cystic lesions are usually diagnosed in the radiologists' practice and therefore their characterization is crucial to determine the clinical approach to be adopted and prognosis. The Bosniak classification based on computed tomography findings has allowed for standardization and categorization of lesions in increasing order of malignancy (I, II, IIF, III and IV) in a simple and accurate way. The present iconographic essay developed with multidetector computed tomography images of selected cases from the archives of the authors' institution, is aimed at describing imaging findings that can help in the diagnosis of renal cysts. (author)

  2. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  3. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  5. Computed tomography of the head in neurological examination of children

    International Nuclear Information System (INIS)

    Baeckman, E.; Egg-Olofsson, O.; Raadberg, C.

    1980-01-01

    A total of 247 children from the departments of pediatrics and neurosurgery were examined with computed tomography of the head during a two year period in 1977-78. Pathological changes were demonstrated in 79 per cent. Supplementary neuro-radiological examination - angiography and encephalography - was necessary in 17 per cent. Computed tomography together with the clinical assessment frequently suffices for final diagnosis. Computed tomography greatly reduces the need for previously used neurological examinations including skull radiography. Complications may ensure because of over-sensitivity to intravenously administered contrast medium in connection with anesthesia, and the radiation dose particularly to the crystalline lens of the eye must be taken into account. Computed tomography should therefore be used only on strict indications after careful scrutiny of the case history and the status. (author)

  6. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Kitslaar, Pieter H.; Broersen, Alexander

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model- based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) im- ages on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods...

  7. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

    Science.gov (United States)

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin

    2015-03-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (pimplants using micro-CT analysis using a region-based segmentation method.

  8. 3D Computer aided treatment planning in endodontics.

    Science.gov (United States)

    van der Meer, Wicher J; Vissink, Arjan; Ng, Yuan Ling; Gulabivala, Kishor

    2016-02-01

    Obliteration of the root canal system due to accelerated dentinogenesis and dystrophic calcification can challenge the achievement of root canal treatment goals. This paper describes the application of 3D digital mapping technology for predictable navigation of obliterated canal systems during root canal treatment to avoid iatrogenic damage of the root. Digital endodontic treatment planning for anterior teeth with severely obliterated root canal systems was accomplished with the aid of computer software, based on cone beam computer tomography (CBCT) scans and intra-oral scans of the dentition. On the basis of these scans, endodontic guides were created for the planned treatment through digital designing and rapid prototyping fabrication. The custom-made guides allowed for an uncomplicated and predictable canal location and management. The method of digital designing and rapid prototyping of endodontic guides allows for reliable and predictable location of root canals of teeth with calcifically metamorphosed root canal systems. The endodontic directional guide facilitates difficult endodontic treatments at little additional cost. Copyright © 2016. Published by Elsevier Ltd.

  9. Effects of computer tomography on diagnosis of neurological and neurosurgical diseases

    International Nuclear Information System (INIS)

    Katzner, E.

    1981-01-01

    Computer tomography is presently the primary procedure for correct diagnosis of many neurological and neurosurgical diseases. Other expensive and riskier diagnostic methods have become superfluous. Selective and clearly indicated application of the undoubtedly expensive computer tomography ultimately spares unnecessary costs for hospitalization and less conclusive examination methods. Wheras the indications in the craniocerebral region can now be considered confirmed, spinal computer tomography is still in the development stage. With certain indications, e.g. in prolapsed lumbar intervertebral disk, a similar performance to that of CT can be obtained with myelography, so that the latter method is likely to be superceded by computer tomography. (orig.) [de

  10. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  11. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias; Furtwaengler, Alex

    2003-01-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST ( 5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  12. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  13. Automatic Delineation of On-Line Head-And-Neck Computed Tomography Images: Toward On-Line Adaptive Radiotherapy

    International Nuclear Information System (INIS)

    Zhang Tiezhi; Chi Yuwei; Meldolesi, Elisa; Yan Di

    2007-01-01

    Purpose: To develop and validate a fully automatic region-of-interest (ROI) delineation method for on-line adaptive radiotherapy. Methods and Materials: On-line adaptive radiotherapy requires a robust and automatic image segmentation method to delineate ROIs in on-line volumetric images. We have implemented an atlas-based image segmentation method to automatically delineate ROIs of head-and-neck helical computed tomography images. A total of 32 daily computed tomography images from 7 head-and-neck patients were delineated using this automatic image segmentation method. Manually drawn contours on the daily images were used as references in the evaluation of automatically delineated ROIs. Two methods were used in quantitative validation: (1) the dice similarity coefficient index, which indicates the overlapping ratio between the manually and automatically delineated ROIs; and (2) the distance transformation, which yields the distances between the manually and automatically delineated ROI surfaces. Results: Automatic segmentation showed agreement with manual contouring. For most ROIs, the dice similarity coefficient indexes were approximately 0.8. Similarly, the distance transformation evaluation results showed that the distances between the manually and automatically delineated ROI surfaces were mostly within 3 mm. The distances between two surfaces had a mean of 1 mm and standard deviation of <2 mm in most ROIs. Conclusion: With atlas-based image segmentation, it is feasible to automatically delineate ROIs on the head-and-neck helical computed tomography images in on-line adaptive treatments

  14. Non-invasive Heart Team assessment of multivessel coronary disease with coronary computed tomography angiography based on SYNTAX score II treatment recommendations: design and rationale of the randomised SYNTAX III Revolution trial

    NARCIS (Netherlands)

    Cavalcante, Rafael; Onuma, Yoshinobu; Sotomi, Yohei; Collet, Carlos; Thomsen, Brian; Rogers, Campbell; Zeng, Yaping; Tenekecioglu, Erhan; Asano, Taku; Miyasaki, Yosuke; Abdelghani, Mohammad; Morel, Marie-Angèle; Serruys, Patrick W.

    2017-01-01

    The aim of this study was to investigate whether a Heart Team decision-making process regarding the choice of revascularisation strategy based on non-invasive coronary multislice computed tomography angiography (MSCT) assessment of coronary artery disease (CAD) is equivalent to the standard-of-care

  15. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  16. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  17. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  18. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  20. Utility of screening computed tomography of chest, abdomen and pelvis in patients after heart transplantation

    International Nuclear Information System (INIS)

    Dasari, Tarun W.; Pavlovic-Surjancev, Biljana; Dusek, Linda; Patel, Nilamkumar; Heroux, Alain L.

    2011-01-01

    Introduction: Malignancy is a late cause of mortality in heart transplant recipients. It is unknown if screening computed tomography scan would lead to early detection of such malignancies or serious vascular anomalies post heart transplantation. Methods: This is a single center observational study of patients undergoing surveillance computed tomography of chest, abdomen and pelvis atleast 5 years after transplantation. Abnormal findings, included pulmonary nodules, lymphadenopathy and intra-thoracic and intra-abdominal masses and vascular anomalies such as abdominal aortic aneurysm. The clinical follow up of each of these major abnormal findings is summarized. Results: A total of 63 patients underwent computed tomography scan of chest, abdomen and pelvis at least 5 years after transplantation. Of these, 54 (86%) were male and 9 (14%) were female. Mean age was 52 ± 9.2 years. Computed tomography revealed 1 lung cancer (squamous cell) only. Non specific pulmonary nodules were seen in 6 patients (9.5%). The most common incidental finding was abdominal aortic aneurysms (N = 6 (9.5%)), which necessitated follow up computed tomography (N = 5) or surgery (N = 1). Mean time to detection of abdominal aortic aneurysms from transplantation was 14.6 ± 4.2 years. Mean age at the time of detection of abdominal aortic aneurysms was 74.5 ± 3.2 years. Conclusion: Screening computed tomography scan in patients 5 years from transplantation revealed only one malignancy but lead to increased detection of abdominal aortic aneurysms. Thus the utility is low in terms of detection of malignancy. Based on this study we do not recommend routine computed tomography post heart transplantation.

  1. Effect of Novel Amplitude/Phase Binning Algorithm on Commercial Four-Dimensional Computed Tomography Quality

    International Nuclear Information System (INIS)

    Olsen, Jeffrey R.; Lu Wei; Hubenschmidt, James P.; Nystrom, Michelle M.; Klahr, Paul; Bradley, Jeffrey D.; Low, Daniel A.; Parikh, Parag J.

    2008-01-01

    Purpose: Respiratory motion is a significant source of anatomic uncertainty in radiotherapy planning and can result in errors of portal size and the subsequent radiation dose. Although four-dimensional computed tomography allows for more accurate analysis of the respiratory cycle, breathing irregularities during data acquisition can cause considerable image distortions. The aim of this study was to examine the effect of respiratory irregularities on four-dimensional computed tomography, and to evaluate a novel image reconstruction algorithm using percentile-based tagging of the respiratory cycle. Methods and Materials: Respiratory-correlated helical computed tomography scans were acquired for 11 consecutive patients. The inspiration and expiration data sets were reconstructed using the default phase-based method, as well as a novel respiration percentile-based method with patient-specific metrics to define the ranges of the reconstruction. The image output was analyzed in a blinded fashion for the phase- and percentile-based reconstructions to determine the prevalence and severity of the image artifacts. Results: The percentile-based algorithm resulted in a significant reduction in artifact severity compared with the phase-based algorithm, although the overall artifact prevalence did not differ between the two algorithms. The magnitude of differences in respiratory tag placement between the phase- and percentile-based algorithms correlated with the presence of image artifacts. Conclusion: The results of our study have indicated that our novel four-dimensional computed tomography reconstruction method could be useful in detecting clinically relevant image distortions that might otherwise go unnoticed and to reduce the image distortion associated with some respiratory irregularities. Additional work is necessary to assess the clinical impact on areas of possible irregular breathing

  2. [Contribution of X-ray computed tomography in the evaluation of kidney performance].

    Science.gov (United States)

    Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent

    2012-07-01

    X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. Copyright © 2011 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  3. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.L. [Department of Radiology, Ipswich Hospital, Ipswich IP4 5PD (United Kingdom)], E-mail: simon.smith@ipswichhospital.nhs.uk; Hampson, F. [Department of Radiology, Addenbrooke' s Hospital NHS Trust, Cambridge (United Kingdom); Duxbury, M. [Department of Surgery, Royal Infirmary of Edinburgh, Little France, Edinburgh EH16 4SU (United Kingdom); Rae, D.M.; Sinclair, M.T. [Department of Pancreaticobiliary surgery, Ipswich Hospital, Ipswich IP4 5PD (United Kingdom)

    2008-08-15

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications.

  4. Novel application of quantitative single-photon emission computed-tomography/computed tomography to predict early response to methimazole in Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Bang, Ji In; Kim, Ji Young; Moon, Jae Hoon [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); So, Young [Dept. of Nuclear Medicine, Konkuk University Medical Center, Seoul (Korea, Republic of); Lee, Won Woo [Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul (Korea, Republic of)

    2017-06-15

    Since Graves' disease (GD) is resistant to antithyroid drugs (ATDs), an accurate quantitative thyroid function measurement is required for the prediction of early responses to ATD. Quantitative parameters derived from the novel technology, single-photon emission computed tomography/computed tomography (SPECT/CT), were investigated for the prediction of achievement of euthyroidism after methimazole (MMI) treatment in GD. A total of 36 GD patients (10 males, 26 females; mean age, 45.3 ± 13.8 years) were enrolled for this study, from April 2015 to January 2016. They underwent quantitative thyroid SPECT/CT 20 minutes post-injection of {sup 99m}Tc-pertechnetate (5 mCi). Association between the time to biochemical euthyroidism after MMI treatment and uptake, standardized uptake value (SUV), functional thyroid mass (SUVmean × thyroid volume) from the SPECT/CT, and clinical/biochemical variables, were investigated. GD patients had a significantly greater %uptake (6.9 ± 6.4%) than historical control euthyroid patients (n = 20, 0.8 ± 0.5%, p < 0.001) from the same quantitative SPECT/CT protocol. Euthyroidism was achieved in 14 patients at 156 ± 62 days post-MMI treatment, but 22 patients had still not achieved euthyroidism by the last follow-up time-point (208 ± 80 days). In the univariate Cox regression analysis, the initial MMI dose (p = 0.014), %uptake (p = 0.015), and functional thyroid mass (p = 0.016) were significant predictors of euthyroidism in response to MMI treatment. However, only uptake remained significant in a multivariate Cox regression analysis (p = 0.034). A uptake cutoff of 5.0% dichotomized the faster responding versus the slower responding GD patients (p = 0.006). A novel parameter of thyroid uptake from quantitative SPECT/CT is a predictive indicator of an early response to MMI in GD patients.

  5. Positive ventriculography and computer assisted tomography of the skull in the evaluation of megalocephaly in newborns and infants

    International Nuclear Information System (INIS)

    Kellermann, K.; Heuser, L.; Bliesener, J.A.

    1979-01-01

    To clarify indications and limits of computer assisted tomography and positive ventriculography the results of both methods were compared with each other retrospectively in 55 macrocephalic newborns and infants. It could be shown that positive ventriculography, even if combined with coronal views, was superseded by computer assisted tomography to only a certain extent. To complete the appropriate diagnosis preoperatively positive ventriculography was necessary most often in patients with paranatal disturbances who had undergone intensive care treatment. The non-invasive method of computer assisted tomography often yielded sufficient information on localisation, size, and nature of the underlying pathologic process. Both methods turned out to be complementary when topographical and functional interrelations of cranial cysts were to be analysed, or when anatomical details had to be demonstrated, especially structures of the midline and of the posterior fossa, which could not be visualized by computer assisted tomography alone. (orig.) [de

  6. Radiation dose in cone-beam computed tomography: myth or reality

    International Nuclear Information System (INIS)

    Madi, Medhini

    2013-01-01

    In the growing inventory of clinical computed tomography technologies, cone-beam X-ray computed tomography is a relatively recent instalment. It is an advancement in computed tomography imaging which is designed to provide relatively low-dose high-spatial-resolution visualization of high contrast structures in the head and neck and other anatomic areas. Comparatively low dosing requirements and relatively compact design has led to intense interest in surgical planning and intra-operative cone-beam computed tomography applications, particularly in head and neck, and also in spinal, thoracic, abdominal and orthopaedic procedures. The use of this emerging imaging technology, which has potential applications for imaging of high-contrast structures in the head and neck as well as dentomaxillofacial regions, has been the subject of criticism as well as acclaim. This paper envisages to discuss the state-of-the-art of the technique. (author)

  7. Computer tomography in the diagnosis of liver diseases

    International Nuclear Information System (INIS)

    Petkov, D.; Zhelyazkov, S.; Nedelkov, G.

    1983-01-01

    The modern achievements in the clinical study and diagnosis of liver diseases has definitely been associated with the application of whole body computer tomography (CT) in the practice. The diagnostic possibilities of the method come from high contrast and spacial disjunctive capabilities. Visualization of local lesions is associated with their size and the differences in their densitometric compactness from that of the normal parenchyma. The advantages of computer tomography in the diagnosis of liver diseases is discussed. They are associated with the possibilities for densitometric analysis of the pathologic changes, which opens a way for a probable qualitative diagnosis. Diffuse processes in the liver are relative indication for performing computer tomography. Examination under conditions of contrast amplification is indicated in cases when the nature of the lesion has to be specified and a ''negative'' result does not concur with the clinical manifestations. (authors)

  8. Computed Tomography Technology: Development and Applications for Defence

    International Nuclear Information System (INIS)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-01-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT and E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  9. X-Ray Computed Tomography of Tranquility Base Moon Rock

    Science.gov (United States)

    Jones, Justin S.; Garvin, Jim; Viens, Mike; Kent, Ryan; Munoz, Bruno

    2016-01-01

    X-ray Computed Tomography (CT) was used for the first time on the Apollo 11 Lunar Sample number 10057.30, which had been previously maintained by the White House, then transferred back to NASA under the care of Goddard Space Flight Center. Results from this analysis show detailed images of the internal structure of the moon rock, including vesicles (pores), crystal needles, and crystal bundles. These crystals, possibly the common mineral ilmenite, are found in abundance and with random orientation. Future work, in particular a greater understanding of these crystals and their formation, may lead to a more in-depth understanding of the lunar surface evolution and mineral content.

  10. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  11. Development of a proton Computed Tomography Detector System

    Energy Technology Data Exchange (ETDEWEB)

    Naimuddin, Md. [Delhi U.; Coutrakon, G. [Northern Illinois U.; Blazey, G. [Northern Illinois U.; Boi, S. [Northern Illinois U.; Dyshkant, A. [Northern Illinois U.; Erdelyi, B. [Northern Illinois U.; Hedin, D. [Northern Illinois U.; Johnson, E. [Northern Illinois U.; Krider, J. [Northern Illinois U.; Rukalin, V. [Northern Illinois U.; Uzunyan, S. A. [Northern Illinois U.; Zutshi, V. [Northern Illinois U.; Fordt, R. [Fermilab; Sellberg, G. [Fermilab; Rauch, J. E. [Fermilab; Roman, M. [Fermilab; Rubinov, P. [Fermilab; Wilson, P. [Fermilab

    2016-02-04

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  12. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  13. A bent Laue-Laue monochromator for a synchrotron-based computed tomography system

    CERN Document Server

    Ren, B; Chapman, L D; Ivanov, I; Wu, X Y; Zhong, Z; Huang, X

    1999-01-01

    We designed and tested a two-crystal bent Laue-Laue monochromator for wide, fan-shaped synchrotron X-ray beams for the program multiple energy computed tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT employs monochromatic X-ray beams from the NSLS's X17B superconducting wiggler beamline for computed tomography (CT) with an improved image quality. MECT uses a fixed horizontal fan-shaped beam with the subject's apparatus rotating around a vertical axis. The new monochromator uses two Czochralski-grown Si crystals, 0.7 and 1.4 mm thick, respectively, and with thick ribs on their upper and lower ends. The crystals are bent cylindrically, with the axis of the cylinder parallel to the fan beam, using 4-rod benders with two fixed rods and two movable ones. The bent-crystal feature of the monochromator resolved the difficulties we had had with the flat Laue-Laue design previously used in MECT, which included (a) inadequate beam intensity, (b) excessive fluctuations in beam intensity, and (c) i...

  14. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches.

    Science.gov (United States)

    Nada, Rania M; Maal, Thomas J J; Breuning, K Hero; Bergé, Stefaan J; Mostafa, Yehya A; Kuijpers-Jagtman, Anne Marie

    2011-02-09

    Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16) for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27) for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.

  15. Assessement of computer tomography usefulness in the diagnosis of arterial hypertension in adrenal diseases

    International Nuclear Information System (INIS)

    Pacho, R.; Feltynowski, T.

    1981-01-01

    The results of computer tomoqraphy done in 105 patients with hypertension due to various adrenal diseases diagnosed clinically and after laboratory investigations were analysed. The investigation was done with a Delta-Scan Ohio-Nuclear-Siemens unit. In 35 cases the findings of computer tomography were confirmed surgically: 12 cases of adrenal adenoma the smallest one had 5 mm in diameter due to primary hyperaidosteronism, 3 cases of adenoma, 2 carcinomas and 1 case of adrenocortical hypertrophy in Cushing's sydrome as well as 15 phaeochromocytomas inclunding two situated outside the adrenals. A case of ganglioneuroma in a 3-year-old child was also diagnosed correctly. The characteristic features of pathological adrenal changes observed during computer tomography in these patients were described. The high effectiveness of the diagnoses based on the results of laboratory investigations and computer tomography is stressed. (author)

  16. Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Eun; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Jung, Woo Hyun; Choi, Byeong Don [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2016-12-15

    The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54⁓2.33, 5.16⁓8.06, 9.03⁓20.11 ml in MIP, respectively, 0.00⁓1.48, 0.00⁓8.47, 1.42⁓24.85 ml in MinIP, respectively and 0.00⁓1.17, 0.00⁓2.19, 0.04⁓3.35 ml in AVG, respectively. After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  17. Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours

    International Nuclear Information System (INIS)

    Amthauer, H.; Denecke, T.; Ruf, J.; Gutberlet, M.; Felix, R.; Lemke, A.J.; Rohlfing, T.; Boehmig, M.; Ploeckinger, U.

    2005-01-01

    The objective was the evaluation of single photon emission computed tomography (SPECT) with integrated low dose computed tomography (CT) in comparison with a retrospective fusion of SPECT and high-resolution CT and a side-by-side analysis for lesion localisation in patients with neuroendocrine tumours. Twenty-seven patients were examined by multidetector CT. Additionally, as part of somatostatin receptor scintigraphy (SRS), an integrated SPECT-CT was performed. SPECT and CT data were fused using software with a registration algorithm based on normalised mutual information. The reliability of the topographic assignment of lesions in SPECT-CT, retrospective fusion and side-by-side analysis was evaluated by two blinded readers. Two patients were not enrolled in the final analysis because of misregistrations in the retrospective fusion. Eighty-seven foci were included in the analysis. For the anatomical assignment of foci, SPECT-CT and retrospective fusion revealed overall accuracies of 91 and 94% (side-by-side analysis 86%). The correct identification of foci as lymph node manifestations (n=25) was more accurate by retrospective fusion (88%) than from SPECT-CT images (76%) or by side-by-side analysis (60%). Both modalities of image fusion appear to be well suited for the localisation of SRS foci and are superior to side-by-side analysis of non-fused images especially concerning lymph node manifestations. (orig.)

  18. Spectral Imaging Technology-Based Evaluation of Radiation Treatment Planning to Remove Contrast Agent Artifacts.

    Science.gov (United States)

    Yi-Qun, Xu; Wei, Liu; Xin-Ye, Ni

    2016-10-01

    This study employs dual-source computed tomography single-spectrum imaging to evaluate the effects of contrast agent artifact removal and the computational accuracy of radiotherapy treatment planning improvement. The phantom, including the contrast agent, was used in all experiments. The amounts of iodine in the contrast agent were 30, 15, 7.5, and 0.75 g/100 mL. Two images with different energy values were scanned and captured using dual-source computed tomography (80 and 140 kV). To obtain a fused image, 2 groups of images were processed using single-energy spectrum imaging technology. The Pinnacle planning system was used to measure the computed tomography values of the contrast agent and the surrounding phantom tissue. The difference between radiotherapy treatment planning based on 80 kV, 140 kV, and energy spectrum image was analyzed. For the image with high iodine concentration, the quality of the energy spectrum-fused image was the highest, followed by that of the 140-kV image. That of the 80-kV image was the worst. The difference in the radiotherapy treatment results among the 3 models was significant. When the concentration of iodine was 30 g/100 mL and the distance from the contrast agent at the dose measurement point was 1 cm, the deviation values (P) were 5.95% and 2.20% when image treatment planning was based on 80 and 140 kV, respectively. When the concentration of iodine was 15 g/100 mL, deviation values (P) were -2.64% and -1.69%. Dual-source computed tomography single-energy spectral imaging technology can remove contrast agent artifacts to improve the calculated dose accuracy in radiotherapy treatment planning. © The Author(s) 2015.

  19. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  20. Prognostic Evaluation of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Endometrial Cancer

    DEFF Research Database (Denmark)

    Vilstrup, Mie Holm; Jochumsen, Kirsten M; Hess, Søren

    2017-01-01

    .19-8.49) and 1.93 (0.80-4.68), respectively. Whole-body cTLG of greater than or equal to 176.1 g yielded a hazard ratio of 5.70 (1.94-16.78) for OS in a multivariate analysis. CONCLUSIONS: Preoperative SUVmax and cTLG showed potential as independent prognostic markers of OS in patients with primarily high...... and a preoperative F-fluorodeoxyglucose positron emission tomography/computed tomography before curatively intended treatment were included. The scans were evaluated using standard uptake values [maximum standard uptake value (SUVmax) and partial volume corrected (c) mean standardized uptake value (SUVmean...... proportional regression models were used for prognostic evaluation. RESULTS: Eighty-three patients (median age, 69.9 y; range, 26.8-91.1) with primarily high-risk endometrial cancer or suspected high The International Federation of Gynecology and Obstetrics stage were included. Mean follow-up time was 3...

  1. Rapid data processing for ultrafast X-ray computed tomography using scalable and modular CUDA based pipelines

    Science.gov (United States)

    Frust, Tobias; Wagner, Michael; Stephan, Jan; Juckeland, Guido; Bieberle, André

    2017-10-01

    Ultrafast X-ray tomography is an advanced imaging technique for the study of dynamic processes basing on the principles of electron beam scanning. A typical application case for this technique is e.g. the study of multiphase flows, that is, flows of mixtures of substances such as gas-liquidflows in pipelines or chemical reactors. At Helmholtz-Zentrum Dresden-Rossendorf (HZDR) a number of such tomography scanners are operated. Currently, there are two main points limiting their application in some fields. First, after each CT scan sequence the data of the radiation detector must be downloaded from the scanner to a data processing machine. Second, the current data processing is comparably time-consuming compared to the CT scan sequence interval. To enable online observations or use this technique to control actuators in real-time, a modular and scalable data processing tool has been developed, consisting of user-definable stages working independently together in a so called data processing pipeline, that keeps up with the CT scanner's maximal frame rate of up to 8 kHz. The newly developed data processing stages are freely programmable and combinable. In order to achieve the highest processing performance all relevant data processing steps, which are required for a standard slice image reconstruction, were individually implemented in separate stages using Graphics Processing Units (GPUs) and NVIDIA's CUDA programming language. Data processing performance tests on different high-end GPUs (Tesla K20c, GeForce GTX 1080, Tesla P100) showed excellent performance. Program Files doi:http://dx.doi.org/10.17632/65sx747rvm.1 Licensing provisions: LGPLv3 Programming language: C++/CUDA Supplementary material: Test data set, used for the performance analysis. Nature of problem: Ultrafast computed tomography is performed with a scan rate of up to 8 kHz. To obtain cross-sectional images from projection data computer-based image reconstruction algorithms must be applied. The

  2. Anatomical structure of lingual foramen in cone beam computed tomography

    International Nuclear Information System (INIS)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae

    2004-01-01

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 ± 0.08, and both lateral lingual foramina was 0.20 ± 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm ± 0.28, right lateral lingual foramen was 0.92 mm ± 0.23, and left lateral lingual foramen was 0.88 mm ± 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  3. Anatomical structure of lingual foramen in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 {+-} 0.08, and both lateral lingual foramina was 0.20 {+-} 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm {+-} 0.28, right lateral lingual foramen was 0.92 mm {+-} 0.23, and left lateral lingual foramen was 0.88 mm {+-} 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  4. Emergency computed tomography for acute pelvic trauma: Where is the bleeder?

    International Nuclear Information System (INIS)

    Hallinan, J.T.P.D.; Tan, C.H.; Pua, U.

    2014-01-01

    Contrast medium extravasation at computed tomography (CT) is an accurate indicator of active haemorrhage in pelvic trauma. When this is present, potentially lifesaving surgical or endovascular treatment should be considered. Identification of the site or territory of haemorrhage is helpful for the interventional radiologist as it allows for focused angiographic evaluation and expedites haemostatic angio-embolisation. Even with thin-section arterial phase CT, tracing the bleeding vessel is not always possible and is often time consuming. We introduce a technique for predicting the bleeding vessel based on knowledge of the cross-sectional anatomical territory of the vessel as an alternative to tracing the vessel's course. Several case examples with digital subtraction angiography (DSA) correlation will be provided

  5. Computational adaptive optics for broadband interferometric tomography of tissues and cells

    Science.gov (United States)

    Adie, Steven G.; Mulligan, Jeffrey A.

    2016-03-01

    Adaptive optics (AO) can shape aberrated optical wavefronts to physically restore the constructive interference needed for high-resolution imaging. With access to the complex optical field, however, many functions of optical hardware can be achieved computationally, including focusing and the compensation of optical aberrations to restore the constructive interference required for diffraction-limited imaging performance. Holography, which employs interferometric detection of the complex optical field, was developed based on this connection between hardware and computational image formation, although this link has only recently been exploited for 3D tomographic imaging in scattering biological tissues. This talk will present the underlying imaging science behind computational image formation with optical coherence tomography (OCT) -- a beam-scanned version of broadband digital holography. Analogous to hardware AO (HAO), we demonstrate computational adaptive optics (CAO) and optimization of the computed pupil correction in 'sensorless mode' (Zernike polynomial corrections with feedback from image metrics) or with the use of 'guide-stars' in the sample. We discuss the concept of an 'isotomic volume' as the volumetric extension of the 'isoplanatic patch' introduced in astronomical AO. Recent CAO results and ongoing work is highlighted to point to the potential biomedical impact of computed broadband interferometric tomography. We also discuss the advantages and disadvantages of HAO vs. CAO for the effective shaping of optical wavefronts, and highlight opportunities for hybrid approaches that synergistically combine the unique advantages of hardware and computational methods for rapid volumetric tomography with cellular resolution.

  6. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  7. A general class of preconditioners for statistical iterative reconstruction of emission computed tomography

    International Nuclear Information System (INIS)

    Chinn, G.; Huang, S.C.

    1997-01-01

    A major drawback of statistical iterative image reconstruction for emission computed tomography is its high computational cost. The ill-posed nature of tomography leads to slow convergence for standard gradient-based iterative approaches such as the steepest descent or the conjugate gradient algorithm. In this paper new theory and methods for a class of preconditioners are developed for accelerating the convergence rate of iterative reconstruction. To demonstrate the potential of this class of preconditioners, a preconditioned conjugate gradient (PCG) iterative algorithm for weighted least squares reconstruction (WLS) was formulated for emission tomography. Using simulated positron emission tomography (PET) data of the Hoffman brain phantom, it was shown that the convergence rate of the PCG can reduce the number of iterations of the standard conjugate gradient algorithm by a factor of 2--8 times depending on the convergence criterion

  8. Evaluation of resectability of renal cell carcinoma by computed tomography

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Matsumoto, Kunihiko; Tatezawa, Takashi; Kikuchi, Yoichi; Akisada, Masahiro; Kitagawa, Ryuichi

    1982-01-01

    Renal cell carcinoma is one of the unique neoplasm which is characterized by disappearing of the metastatic tumors after removal of the primary lesion. Angiography has been performed to evaluate the resectability of the primary tumor by nephrectomy in the past. With the use of computed tomography, detailed evaluation of the retroperitoneal structures is now possible. We have evaluated the resectability of renal cell tumor by computed tomography and compared the results with the angiographic findings and operative findings. Computed tomography is very accurate in determining the extent of the tumor especially in evaluation of tumor and the Gerota's fascia, which is essential to determine the resectability of the tumor. Informations about lymph node metastasis and invasion to the renal veins or inferior vena cava are also obtained.FIn most of the cases, angiography can be spared if computed tomography is properly performed. (author)

  9. Laryngopyocele: signs on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nazaroglu, Hasan E-mail: hnazarog@dicle.edu.tr; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual.

  10. Laryngopyocele: signs on computed tomography

    International Nuclear Information System (INIS)

    Nazaroglu, Hasan; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual

  11. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  12. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  13. Computed tomography in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki

    1990-01-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.)

  14. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  15. Registration of human skull computed tomography data to an ultrasound treatment space using a sparse high frequency ultrasound hemispherical array

    Energy Technology Data Exchange (ETDEWEB)

    O’Reilly, Meaghan A., E-mail: moreilly@sri.utoronto.ca; Jones, Ryan M. [Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G 1L7 (Canada); Birman, Gabriel [Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario M4N 3M5 (Canada); Hynynen, Kullervo [Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G 1L7 (Canada); Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3G9 (Canada)

    2016-09-15

    Purpose: Transcranial focused ultrasound (FUS) shows great promise for a range of therapeutic applications in the brain. Current clinical investigations rely on the use of magnetic resonance imaging (MRI) to monitor treatments and for the registration of preoperative computed tomography (CT)-data to the MR images at the time of treatment to correct the sound aberrations caused by the skull. For some applications, MRI is not an appropriate choice for therapy monitoring and its cost may limit the accessibility of these treatments. An alternative approach, using high frequency ultrasound measurements to localize the skull surface and register CT data to the ultrasound treatment space, for the purposes of skull-related phase aberration correction and treatment targeting, has been developed. Methods: A prototype high frequency, hemispherical sparse array was fabricated. Pulse-echo measurements of the surface of five ex vivo human skulls were made, and the CT datasets of each skull were obtained. The acoustic data were used to rigidly register the CT-derived skull surface to the treatment space. The ultrasound-based registrations of the CT datasets were compared to the gold-standard landmark-based registrations. Results: The results show on an average sub-millimeter (0.9 ± 0.2 mm) displacement and subdegree (0.8° ± 0.4°) rotation registration errors. Numerical simulations predict that registration errors on this scale will result in a mean targeting error of 1.0 ± 0.2 mm and reduction in focal pressure of 1.0% ± 0.6% when targeting a midbrain structure (e.g., hippocampus) using a commercially available low-frequency brain prototype device (InSightec, 230 kHz brain system). Conclusions: If combined with ultrasound-based treatment monitoring techniques, this registration method could allow for the development of a low-cost transcranial FUS treatment platform to make this technology more widely available.

  16. Registration of human skull computed tomography data to an ultrasound treatment space using a sparse high frequency ultrasound hemispherical array.

    Science.gov (United States)

    O'Reilly, Meaghan A; Jones, Ryan M; Birman, Gabriel; Hynynen, Kullervo

    2016-09-01

    Transcranial focused ultrasound (FUS) shows great promise for a range of therapeutic applications in the brain. Current clinical investigations rely on the use of magnetic resonance imaging (MRI) to monitor treatments and for the registration of preoperative computed tomography (CT)-data to the MR images at the time of treatment to correct the sound aberrations caused by the skull. For some applications, MRI is not an appropriate choice for therapy monitoring and its cost may limit the accessibility of these treatments. An alternative approach, using high frequency ultrasound measurements to localize the skull surface and register CT data to the ultrasound treatment space, for the purposes of skull-related phase aberration correction and treatment targeting, has been developed. A prototype high frequency, hemispherical sparse array was fabricated. Pulse-echo measurements of the surface of five ex vivo human skulls were made, and the CT datasets of each skull were obtained. The acoustic data were used to rigidly register the CT-derived skull surface to the treatment space. The ultrasound-based registrations of the CT datasets were compared to the gold-standard landmark-based registrations. The results show on an average sub-millimeter (0.9 ± 0.2 mm) displacement and subdegree (0.8° ± 0.4°) rotation registration errors. Numerical simulations predict that registration errors on this scale will result in a mean targeting error of 1.0 ± 0.2 mm and reduction in focal pressure of 1.0% ± 0.6% when targeting a midbrain structure (e.g., hippocampus) using a commercially available low-frequency brain prototype device (InSightec, 230 kHz brain system). If combined with ultrasound-based treatment monitoring techniques, this registration method could allow for the development of a low-cost transcranial FUS treatment platform to make this technology more widely available.

  17. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  18. Comparison of computed tomography dose reporting software

    International Nuclear Information System (INIS)

    Abdullah, A.; Sun, Z.; Pongnapang, N.; Ng, K. H.

    2008-01-01

    Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover (Germany)), ImPACT CT Patients Dosimetry Calculator (version 0.99x, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck (Germany)), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen (Germany)) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen (Germany)) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly. (authors)

  19. Ex-situ X-ray computed tomography data for a non-crimp fabric based glass fibre composite under fatigue loading

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2017-01-01

    The data published with this article are high resolution X-ray computed tomography (CT) data obtained during an ex-situ fatigue test of a coupon test specimen made from a non-crimp fabric based glass fibre composite similar to those used for wind turbine blades. The fatigue test was interrupted...

  20. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  1. Computed tomography of cryogenic cells

    International Nuclear Information System (INIS)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-01-01

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions

  2. Computed tomography of the central nervous system in small animals

    International Nuclear Information System (INIS)

    Tipold, A.; Tipold, E.

    1991-01-01

    With computed tomography in 44 small animals some well defined anatomical structures and pathological processes of the central nervous system are described. Computed tomography is not only necessary for the diagnosis of tumors; malformations, inflammatory, degenerative and vascular diseases and traumas are also visible

  3. Evaluation of transurethral ultrasonography and computed tomography in the staging of bladder tumors

    International Nuclear Information System (INIS)

    Yamakawa, Kensuke; Hoshina, Akira; Tochigi, Hiromi; Kawamura, Juichi

    1987-01-01

    A definitive pathologic diagnosis was made in 47 patients with bladder tumors from cystectomy specimens or by surgical exploration. The tumor was staged in 35 cases by transurethral ultrasonography and in 39 cases by computed tomography. We obtained the following results : the accuracy was 83 % using transurethral sonography, 77 % using computed tomography. Although transurethral ultrasonography is more advantageous than computed tomography in the low stage in regard to accuracy, computed tomography is excellent method to obtain information about the tumor invasion and/or metastases. Of 25 cases combind with computed tomography and transurethral sonography. tumors were correctly staged by both methods in 18 cases (72 %). Histopathological stage was consistent with neither ultrasonographic stage nor computed tomographic stage in 2 cases, and any of these tumors was correctly staged by either of these methods. Although transurethral ultrasonography and computed tomography improve the clinical stage of the bladder tumors separately, some limitations and problems was recognized on using together with these methods for staging the bladder tumors. (author)

  4. Noninvasive Computed Tomography-based Risk Stratification of Lung Adenocarcinomas in the National Lung Screening Trial.

    Science.gov (United States)

    Maldonado, Fabien; Duan, Fenghai; Raghunath, Sushravya M; Rajagopalan, Srinivasan; Karwoski, Ronald A; Garg, Kavita; Greco, Erin; Nath, Hrudaya; Robb, Richard A; Bartholmai, Brian J; Peikert, Tobias

    2015-09-15

    Screening for lung cancer using low-dose computed tomography (CT) reduces lung cancer mortality. However, in addition to a high rate of benign nodules, lung cancer screening detects a large number of indolent cancers that generally belong to the adenocarcinoma spectrum. Individualized management of screen-detected adenocarcinomas would be facilitated by noninvasive risk stratification. To validate that Computer-Aided Nodule Assessment and Risk Yield (CANARY), a novel image analysis software, successfully risk stratifies screen-detected lung adenocarcinomas based on clinical disease outcomes. We identified retrospective 294 eligible patients diagnosed with lung adenocarcinoma spectrum lesions in the low-dose CT arm of the National Lung Screening Trial. The last low-dose CT scan before the diagnosis of lung adenocarcinoma was analyzed using CANARY blinded to clinical data. Based on their parametric CANARY signatures, all the lung adenocarcinoma nodules were risk stratified into three groups. CANARY risk groups were compared using survival analysis for progression-free survival. A total of 294 patients were included in the analysis. Kaplan-Meier analysis of all the 294 adenocarcinoma nodules stratified into the Good, Intermediate, and Poor CANARY risk groups yielded distinct progression-free survival curves (P < 0.0001). This observation was confirmed in the unadjusted and adjusted (age, sex, race, and smoking status) progression-free survival analysis of all stage I cases. CANARY allows the noninvasive risk stratification of lung adenocarcinomas into three groups with distinct post-treatment progression-free survival. Our results suggest that CANARY could ultimately facilitate individualized management of incidentally or screen-detected lung adenocarcinomas.

  5. Computed tomography of the llama head: technique and normal anatomy

    International Nuclear Information System (INIS)

    Hathcock, J.T.; Pugh, D.G.; Cartee, R.E.; Hammond, L.

    1996-01-01

    Computed tomography was performed on the head of 6 normal adult llamas. The animals were under general anesthesia and positioned in dorsal recumbency on the scanning table. The area scanned was from the external occipital protuberance to the rostral portion of the nasal passage, and the images are presented in both a bone window and a soft tissue window to allow evaluation and identification of the anatomy of the head. Computed tomography of the llama head can be accomplished by most computed tomography scanners utilizing a technique similar to that used in small animals with minor modification of the scanning table

  6. A computed tomography-based spatial normalization for the analysis of [18F] fluorodeoxyglucose positron emission tomography of the brain.

    Science.gov (United States)

    Cho, Hanna; Kim, Jin Su; Choi, Jae Yong; Ryu, Young Hoon; Lyoo, Chul Hyoung

    2014-01-01

    We developed a new computed tomography (CT)-based spatial normalization method and CT template to demonstrate its usefulness in spatial normalization of positron emission tomography (PET) images with [(18)F] fluorodeoxyglucose (FDG) PET studies in healthy controls. Seventy healthy controls underwent brain CT scan (120 KeV, 180 mAs, and 3 mm of thickness) and [(18)F] FDG PET scans using a PET/CT scanner. T1-weighted magnetic resonance (MR) images were acquired for all subjects. By averaging skull-stripped and spatially-normalized MR and CT images, we created skull-stripped MR and CT templates for spatial normalization. The skull-stripped MR and CT images were spatially normalized to each structural template. PET images were spatially normalized by applying spatial transformation parameters to normalize skull-stripped MR and CT images. A conventional perfusion PET template was used for PET-based spatial normalization. Regional standardized uptake values (SUV) measured by overlaying the template volume of interest (VOI) were compared to those measured with FreeSurfer-generated VOI (FSVOI). All three spatial normalization methods underestimated regional SUV values by 0.3-20% compared to those measured with FSVOI. The CT-based method showed slightly greater underestimation bias. Regional SUV values derived from all three spatial normalization methods were correlated significantly (p normalization may be an alternative method for structure-based spatial normalization of [(18)F] FDG PET when MR imaging is unavailable. Therefore, it is useful for PET/CT studies with various radiotracers whose uptake is expected to be limited to specific brain regions or highly variable within study population.

  7. Lynch Syndrome Associated Colon Adenocarcinoma Resembling Lymphoma on Fluoro-Deoxyglucose-Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Aparici, Carina Mari; Win, Aung Zaw

    2015-01-01

    The patient was a 46-year-old Asian male diagnosed with lynch syndrome associated colon adenocarcinoma in the right ascending colon. A presurgical staging 18-fluoro-deoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) found increased metabolic activity in the cervical, axillary, mediastinal, supraclavicular, para-aortic and mesenteric lymph nodes. This pattern of metastasis was very unusual for lynch syndrome associated colon adenocarcinoma and the involvement of those lymph nodes resembles the pattern of spread of lymphoma. He underwent right hemicolectomy and he was subsequently treated with 12 cycles of folinic acid (leucovorin), fluorouracil (5-FU), irinotecan. A restaging FDG-PET/CT at the end of the chemotherapy showed interval decrease in size and metabolic activity in the affected lymph nodes. FDG-PET/CT is a useful imaging modality in following-up the treatment response in colon adenocarcinoma

  8. Multi-Detector Computed Tomography Imaging Techniques in Arterial Injuries

    Directory of Open Access Journals (Sweden)

    Cameron Adler

    2018-04-01

    Full Text Available Cross-sectional imaging has become a critical aspect in the evaluation of arterial injuries. In particular, angiography using computed tomography (CT is the imaging of choice. A variety of techniques and options are available when evaluating for arterial injuries. Techniques involve contrast bolus, various phases of contrast enhancement, multiplanar reconstruction, volume rendering, and maximum intensity projection. After the images are rendered, a variety of features may be seen that diagnose the injury. This article provides a general overview of the techniques, important findings, and pitfalls in cross sectional imaging of arterial imaging, particularly in relation to computed tomography. In addition, the future directions of computed tomography, including a few techniques in the process of development, is also discussed.

  9. Difficulties encountered managing nodules detected during a computed tomography lung cancer screening program.

    Science.gov (United States)

    Veronesi, Giulia; Bellomi, Massimo; Scanagatta, Paolo; Preda, Lorenzo; Rampinelli, Cristiano; Guarize, Juliana; Pelosi, Giuseppe; Maisonneuve, Patrick; Leo, Francesco; Solli, Piergiorgio; Masullo, Michele; Spaggiari, Lorenzo

    2008-09-01

    The main challenge of screening a healthy population with low-dose computed tomography is to balance the excessive use of diagnostic procedures with the risk of delayed cancer detection. We evaluated the pitfalls, difficulties, and sources of mistakes in the management of lung nodules detected in volunteers in the Cosmos single-center screening trial. A total of 5201 asymptomatic high-risk volunteers underwent screening with multidetector low-dose computed tomography. Nodules detected at baseline or new nodules at annual screening received repeat low-dose computed tomography at 1 year if less than 5 mm, repeat low-dose computed tomography 3 to 6 months later if between 5 and 8 mm, and fluorodeoxyglucose positron emission tomography if more than 8 mm. Growing nodules at the annual screening received low-dose computed tomography at 6 months and computed tomography-positron emission tomography or surgical biopsy according to doubling time, type, and size. During the first year of screening, 106 patients underwent lung biopsy and 91 lung cancers were identified (70% were stage I). Diagnosis was delayed (false-negative) in 6 patients (stage IIB in 1 patient, stage IIIA in 3 patients, and stage IV in 2 patients), including 2 small cell cancers and 1 central lesion. Surgical biopsy revealed benign disease (false-positives) in 15 cases (14%). Positron emission tomography sensitivity was 88% for prevalent cancers and 70% for cancers diagnosed after first annual screening. No needle biopsy procedures were performed in this cohort of patients. Low-dose computed tomography screening is effective for the early detection of lung cancers, but nodule management remains a challenge. Computed tomography-positron emission tomography is useful at baseline, but its sensitivity decreases significantly the subsequent year. Multidisciplinary management and experience are crucial for minimizing misdiagnoses.

  10. Radiomic features analysis in computed tomography images of lung nodule classification.

    Directory of Open Access Journals (Sweden)

    Chia-Hung Chen

    Full Text Available Radiomics, which extract large amount of quantification image features from diagnostic medical images had been widely used for prognostication, treatment response prediction and cancer detection. The treatment options for lung nodules depend on their diagnosis, benign or malignant. Conventionally, lung nodule diagnosis is based on invasive biopsy. Recently, radiomics features, a non-invasive method based on clinical images, have shown high potential in lesion classification, treatment outcome prediction.Lung nodule classification using radiomics based on Computed Tomography (CT image data was investigated and a 4-feature signature was introduced for lung nodule classification. Retrospectively, 72 patients with 75 pulmonary nodules were collected. Radiomics feature extraction was performed on non-enhanced CT images with contours which were delineated by an experienced radiation oncologist.Among the 750 image features in each case, 76 features were found to have significant differences between benign and malignant lesions. A radiomics signature was composed of the best 4 features which included Laws_LSL_min, Laws_SLL_energy, Laws_SSL_skewness and Laws_EEL_uniformity. The accuracy using the signature in benign or malignant classification was 84% with the sensitivity of 92.85% and the specificity of 72.73%.The classification signature based on radiomics features demonstrated very good accuracy and high potential in clinical application.

  11. Ultrasonography and computer tomography in the diagnosis of certain abdominal diseases

    International Nuclear Information System (INIS)

    Wawrzynek, Z.

    1981-01-01

    Ultrasonography and computer tomography in the diagnosis of digestive tract and spleen diseases as well as traumas are compared. It is concluded that ultrasonography is nearly as usefull as computer tomography. (author)

  12. Occult primary tumors of the head and neck: accuracy of thallium 201 single-photon emission computed tomography and computed tomography and/or magnetic resonance imaging

    NARCIS (Netherlands)

    van Veen, S. A.; Balm, A. J.; Valdés Olmos, R. A.; Hoefnagel, C. A.; Hilgers, F. J.; Tan, I. B.; Pameijer, F. A.

    2001-01-01

    To determine the accuracy of thallium 201 single-photon emission computed tomography (thallium SPECT) and computed tomography and/or magnetic resonance imaging (CT/MRI) in the detection of occult primary tumors of the head and neck. Study of diagnostic tests. National Cancer Institute, Amsterdam,

  13. Calculating the mounting parameters for Taylor Spatial Frame correction using computed tomography.

    Science.gov (United States)

    Kucukkaya, Metin; Karakoyun, Ozgur; Armagan, Raffi; Kuzgun, Unal

    2011-07-01

    The Taylor Spatial Frame uses a computer program-based six-axis deformity analysis. However, there is often a residual deformity after the initial correction, especially in deformities with a rotational component. This problem can be resolved by recalculating the parameters and inputting all new deformity and mounting parameters. However, this may necessitate repeated x-rays and delay treatment. We believe that error in the mounting parameters is the main reason for most residual deformities. To prevent these problems, we describe a new calculation technique for determining the mounting parameters that uses computed tomography. This technique is especially advantageous for deformities with a rotational component. Using this technique, exact calculation of the mounting parameters is possible and the residual deformity and number of repeated x-rays can be minimized. This new technique is an alternative method to accurately calculating the mounting parameters.

  14. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  15. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Golimbu, C.; Bonamo, J.

    1984-01-01

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  16. The value of computer tomography and sonography in the investigation of the pancreas

    International Nuclear Information System (INIS)

    Lackner, K.; Frommhold, H.; Grauthoff, H.; Moedder, U.; Heuser, L.; Braun, G.; Buurman, R.; Scherer, K.; Hamburg Univ.; Koeln Univ.

    1980-01-01

    Three hundred and five patients were examined by computer tomography and sonography. In 117 patients no abnormalities were found in the pancreas. The accuracy of computer tomography was 87%, of sonography 85%. In 41 patients the presence of a carcinoma of the pancreas was confirmed histologically. In this group the sensitivity of computer tomography was 83%, of sonography 85%. Thirty-four patients suffered from acute pancreatitis. In this group sensitivity of the two methods was equal at 79%. 113 patients had changes of chronic pancreatitis. Sensitivity of computer tomography was 84%, of sonography 70%. Computer tomography is better at demonstrating calcification in the pancreas. Atrophy of the pancreas cannot be diagnosed by sonography. (orig.) [de

  17. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  18. Computed tomography of the mediastinum in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours.

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... information about radiation dose. There always is a risk of complications from general anesthesia or sedation. Every measure will be taken to ... in X-Ray and CT Exams Contrast Materials Anesthesia Safety Children and Radiation Safety ... (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) ...

  20. Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

    International Nuclear Information System (INIS)

    Chen, Dongmei; Zhu, Shouping; Chen, Xueli; Chao, Tiantian; Cao, Xu; Zhao, Fengjun; Huang, Liyu; Liang, Jimin

    2014-01-01

    X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging

  1. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    Carrascosa, Patricia M.; Vallejos, J.; Capunay, Carlos M.; Deviggiano, A.; Carrascosa, Jorge M.

    2007-01-01

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine [es

  2. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography.

    Science.gov (United States)

    Ogo, Takeshi; Fukuda, Tetsuya; Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin; Sanda, Yoshihiro; Morita, Yoshiaki; Asano, Ryotaro; Konagai, Nao; Yasuda, Satoshi

    2017-04-01

    Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1year after BPA. Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Patient Study of In Vivo Verification of Beam Delivery and Range, Using Positron Emission Tomography and Computed Tomography Imaging After Proton Therapy

    International Nuclear Information System (INIS)

    Parodi, Katia; Paganetti, Harald; Shih, Helen A.; Michaud, Susan; Loeffler, Jay S.; DeLaney, Thomas F.; Liebsch, Norbert J.; Munzenrider, John E.; Fischman, Alan J.; Knopf, Antje; Bortfeld, Thomas

    2007-01-01

    Purpose: To investigate the feasibility and value of positron emission tomography and computed tomography (PET/CT) for treatment verification after proton radiotherapy. Methods and Materials: This study included 9 patients with tumors in the cranial base, spine, orbit, and eye. Total doses of 1.8-3 GyE and 10 GyE (for an ocular melanoma) per fraction were delivered in 1 or 2 fields. Imaging was performed with a commercial PET/CT scanner for 30 min, starting within 20 min after treatment. The same treatment immobilization device was used during imaging for all but 2 patients. Measured PET/CT images were coregistered to the planning CT and compared with the corresponding PET expectation, obtained from CT-based Monte Carlo calculations complemented by functional information. For the ocular case, treatment position was approximately replicated, and spatial correlation was deduced from reference clips visible in both the planning radiographs and imaging CT. Here, the expected PET image was obtained from an analytical model. Results: Good spatial correlation and quantitative agreement within 30% were found between the measured and expected activity. For head-and-neck patients, the beam range could be verified with an accuracy of 1-2 mm in well-coregistered bony structures. Low spine and eye sites indicated the need for better fixation and coregistration methods. An analysis of activity decay revealed as tissue-effective half-lives of 800-1,150 s. Conclusions: This study demonstrates the feasibility of postradiation PET/CT for in vivo treatment verification. It also indicates some technological and methodological improvements needed for optimal clinical application

  4. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  5. X-ray computed tomography using curvelet sparse regularization.

    Science.gov (United States)

    Wieczorek, Matthias; Frikel, Jürgen; Vogel, Jakob; Eggl, Elena; Kopp, Felix; Noël, Peter B; Pfeiffer, Franz; Demaret, Laurent; Lasser, Tobias

    2015-04-01

    Reconstruction of x-ray computed tomography (CT) data remains a mathematically challenging problem in medical imaging. Complementing the standard analytical reconstruction methods, sparse regularization is growing in importance, as it allows inclusion of prior knowledge. The paper presents a method for sparse regularization based on the curvelet frame for the application to iterative reconstruction in x-ray computed tomography. In this work, the authors present an iterative reconstruction approach based on the alternating direction method of multipliers using curvelet sparse regularization. Evaluation of the method is performed on a specifically crafted numerical phantom dataset to highlight the method's strengths. Additional evaluation is performed on two real datasets from commercial scanners with different noise characteristics, a clinical bone sample acquired in a micro-CT and a human abdomen scanned in a diagnostic CT. The results clearly illustrate that curvelet sparse regularization has characteristic strengths. In particular, it improves the restoration and resolution of highly directional, high contrast features with smooth contrast variations. The authors also compare this approach to the popular technique of total variation and to traditional filtered backprojection. The authors conclude that curvelet sparse regularization is able to improve reconstruction quality by reducing noise while preserving highly directional features.

  6. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  7. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  8. Prostate cancer nodal oligometastasis accurately assessed using prostate-specific membrane antigen positron emission tomography-computed tomography and confirmed histologically following robotic-assisted lymph node dissection.

    Science.gov (United States)

    O'Kane, Dermot B; Lawrentschuk, Nathan; Bolton, Damien M

    2016-01-01

    We herein present a case of a 76-year-old gentleman, where prostate-specific membrane antigen positron emission tomography-computed tomography (PSMA PET-CT) was used to accurately detect prostate cancer (PCa), pelvic lymph node (LN) metastasis in the setting of biochemical recurrence following definitive treatment for PCa. The positive PSMA PET-CT result was confirmed with histological examination of the involved pelvic LNs following pelvic LN dissection.

  9. Prostate cancer nodal oligometastasis accurately assessed using prostate-specific membrane antigen positron emission tomography-computed tomography and confirmed histologically following robotic-assisted lymph node dissection

    Directory of Open Access Journals (Sweden)

    Dermot B O′Kane

    2016-01-01

    Full Text Available We herein present a case of a 76-year-old gentleman, where prostate-specific membrane antigen positron emission tomography-computed tomography (PSMA PET-CT was used to accurately detect prostate cancer (PCa, pelvic lymph node (LN metastasis in the setting of biochemical recurrence following definitive treatment for PCa. The positive PSMA PET-CT result was confirmed with histological examination of the involved pelvic LNs following pelvic LN dissection.

  10. Computed tomography of the mediastinum in myasthenia gravis

    International Nuclear Information System (INIS)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.; Hamburg Univ.; Hamburg Univ.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours. (orig.) [de

  11. Computed tomography in the evaluation of acquired stenosis in the neonate

    International Nuclear Information System (INIS)

    Faw, K.; Muntz, H.; Siegel, M.; Spector, G.

    1982-01-01

    We studied the feasibility of computed tomographic evaluation of the neonatal airway. Three neonatal larynges, removed at necroscopy, were examined by computed tomography. Good resolution of soft tissue, cartilage and airway lumen was obtained in these small specimens. On the basis of these findings two neonates with acquired subglottic stenosis were examined by endoscopy, soft tissue airway radiographs, and computed tomography. Measurements of radiation dose revealed that a computed tomographic study delivered 36% of the mean tissue dose of standard image intensifier fluoroscopy. Computed tomography and fluoroscopy both demonstrated the degree and length of this stenosis accurately. An advantage of CT over conventional imaging procedures was better definition of the cross sectional area of the airway

  12. Wrist ligament injuries: value of post-arthrography computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Theumann, N.; Schnyder, P.; Meuli, R. [Dept. of Diagnostic and Interventional Radiology, University Hospital, CHUV, Lausanne (Switzerland); Favarger, N. [Clinique Longeraie, Lausanne (Switzerland)

    2001-02-01

    Objective: To evaluate the use of post-arthrography high-resolution computed tomography in wrist ligament injuries.Design and patients: Thirty-six consecutive patients who had a history and clinical findings suggestive of ligamentous injuries of the wrist were prospectively studied. The findings of three-compartment arthrography and post-arthrography computed tomography (arthro-CT) were compared with those of arthroscopy. The evaluation concentrates on the detection and precise localization of ligament lesions in the triangular fibrocartilage (TFC), the scapholunate ligament (SLL) and the lunotriquetral ligament (LTL).Results: For TFC, SLL and LTL lesions, standard arthrography responded with a sensitivity and specificity of 85% and 100%, 85% and 100%, 80% and 100% respectively, while arthro-CT showed a sensitivity and specificity of 85% and 100%, 100% and 100%, 80% and 100% respectively. The precise localization of the lesions was possible only with arthro-CT.Conclusion: The sensitivity and specificity of standard arthrography and arthro-CT are similar, although the latter shows the site of tears or perforation with greater precision, while conventional arthrography demonstrates them indirectly. This precision is essential and may have clinical implications for the success of treatment procedures. (orig.)

  13. Portal venous gas detected on computed tomography in emergency situations: surgery is still necessary.

    Science.gov (United States)

    Monneuse, Olivier; Pilleul, Frank; Barth, Xavier; Gruner, Laurent; Allaouchiche, Bernard; Valette, Pierre-Jean; Tissot, E

    2007-05-01

    Portal venous gas (PVG) has been reported to be associated with lethal surgical diagnosis. Recent studies tend to confirm the clinical significance of gas in the portal vein; however, some patients are managed without surgical treatment. The aim of this study was to assess both the diagnoses and the treatment of patients with PVG in an emergency surgical setting. We performed a retrospective chart review of 15 patients with PVG in the emergency setting detected by computed tomography (CT) between July 1999 and July 2004. Characteristics assessed included age, sex, clinical presentation, first CT diagnosis of both PVG and the underlying pathology, American Society of Anesthesiologists (ASA) score, surgical findings, final clinical diagnosis, duration of hospitalization, and evolution of the illness/mortality. All patients were examined one month after operation. This series of 5 women and 10 men ranged in age from 38 to 90 years at the time they underwent emergency surgical treatment. The mean preoperative ASA score was 4.20. Computed tomography diagnosed the underlying pathology in all cases: bowel obstruction (4 cases), bowel necrosis (9 cases), and diffuse peritonitis (2 cases). The mean length of hospital stay was 12.4 days. The mortality rate was 46.6%; (7 patients). A wide range of pathologies can generate PVG. Computed tomography can detect both the presence of gas and the underlying pathology. In emergency situations, all the diagnosed causal pathologies required a surgical procedure without delay. We report that the prognosis was related to the pathology itself and was not influenced by the presence of PVG.

  14. Fractal analyses of osseous healing using Tuned Aperture Computed Tomography images

    International Nuclear Information System (INIS)

    Nair, M.K.; Nair, U.P.; Seyedain, A.; Webber, R.L.; Piesco, N.P.; Agarwal, S.; Mooney, M.P.; Groendahl, H.G.

    2001-01-01

    The aim of this study was to evaluate osseous healing in mandibular defects using fractal analyses on conventional radiographs and tuned aperture computed tomography (TACT; OrthoTACT, Instrumentarium Imaging, Helsinki, Finland) images. Eighty test sites on the inferior margins of rabbit mandibles were subject to lesion induction and treated with one of the following: no treatment (controls); osteoblasts only; polymer matrix only; or osteoblast-polymer matrix (OPM) combination. Images were acquired using conventional radiography and TACT, including unprocessed TACT (TACT-U) and iteratively restored TACT (TACT-IR). Healing was followed up over time and images acquired at 3, 6, 9, and 12 weeks post-surgery. Fractal dimension (FD) was computed within regions of interest in the defects using the TACT workbench. Results were analyzed for effects produced by imaging modality, treatment modality, time after surgery and lesion location. Histomorphometric data were available to assess ground truth. Significant differences (p<0.0001) were noted based on imaging modality with TACT-IR recording the highest mean fractal dimension (MFD), followed by TACT-U and conventional images, in that order. Sites treated with OPM recorded the highest MFDs among all treatment modalities (p<0.0001). The highest MFD based on time was recorded at 3 weeks and differed significantly with 12 weeks (p<0.035). Correlation of FD with results of histomorphometric data was high (r=0.79; p<0.001). The FD computed on TACT-IR showed the highest correlation with histomorphometric data, thus establishing the fact TACT is a more efficient and accurate imaging modality for quantification of osseous changes within healing bony defects. (orig.)

  15. Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography

    International Nuclear Information System (INIS)

    Hoffmann, Hans; Frieler, Katja; Schlattmann, Peter; Hamm, Bernd; Dewey, Marc

    2010-01-01

    Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiography in a retrospective longitudinal study. MDCT was performed by using a voxel size of 0.5 x 0.35 x 0.35 mm 3 at two time points 25 ± 3 months apart. Non-calcified, calcified and mixed coronary plaque components were analysed by using volumetric measurement. The influence of statin, low-density lipoprotein (LDL) and risk factors was assessed by using a linear random intercept model for plaque growth. The volumes of non-calcified, calcified and mixed coronary plaques significantly (P 3 ) to follow-up (29/17-44, 13/6-29 and 41/20-75 mm 3 ). Statins significantly slowed the growth of non-calcified plaques (statin coefficient β = -0.0036, P = 0.01) but did not significantly affect the growth rate of mixed or calcified plaques. The effect of statin treatment on non-calcified plaques remained significant after adjusting for LDL levels and cardiac risk factors. Quantification using MDCT shows that progression of non-calcified coronary plaques may be slowed by statins. (orig.)

  16. Computed tomography of human joints and radioactive waste drums

    International Nuclear Information System (INIS)

    Martz, Harry E.; Roberson, G. Patrick; Hollerbach, Karin; Logan, Clinton M.; Ashby, Elaine; Bernardi, Richard

    1999-01-01

    X- and gamma-ray imaging techniques in nondestructive evaluation (NDE) and assay (NDA) have seen increasing use in an array of industrial, environmental, military, and medical applications. Much of this growth in recent years is attributed to the rapid development of computed tomography (CT) and the use of NDE throughout the life-cycle of a product. Two diverse examples of CT are discussed, 1.) Our computational approach to normal joint kinematics and prosthetic joint analysis offers an opportunity to evaluate and improve prosthetic human joint replacements before they are manufactured or surgically implanted. Computed tomography data from scanned joints are segmented, resulting in the identification of bone and other tissues of interest, with emphasis on the articular surfaces. 2.) We are developing NDE and NDA techniques to analyze closed waste drums accurately and quantitatively. Active and passive computed tomography (A and PCT) is a comprehensive and accurate gamma-ray NDA method that can identify all detectable radioisotopes present in a container and measure their radioactivity

  17. Pre- and post-radiotherapy computed tomography in laryngeal cancer: imaging-based prediction of local failure

    International Nuclear Information System (INIS)

    Pameijer, Frank A.; Hermans, Robert; Mancuso, Anthony A.; Mendenhall, William M.; Parsons, James T.; Stringer, Scott P.; Kubilis, Paul S.; Tinteren, Harm van

    1999-01-01

    Purpose: To determine if pre-radiotherapy (RT) and/or post-radiotherapy computed tomography (CT) can predict local failure in patients with laryngeal carcinoma treated with definitive RT. Methods and Materials: The pre- and post-RT CT examinations of 59 patients (T3 glottic carcinoma [n = 30] and T1-T4 supraglottic carcinoma [n = 29]) were reviewed. For each patient, the first post-RT CT study between 1 and 6 months after irradiation was used. All patients were treated with definitive hyperfractionated twice-daily continuous-course irradiation to a total dose of 6,720-7,920 cGy, and followed-up clinically for at least 2 years after completion of RT. Local control was defined as absence of primary tumor recurrence and a functioning larynx. On the pre-treatment CT study, each tumor was assigned a high-or low-risk profile for local failure after RT. The post-RT CT examinations were evaluated for post-treatment changes using a three-point post-RT CT-score: 1 = expected post-RT changes; 2 = focal mass with a maximal diameter of 1 cm, or < 50% estimated tumor volume reduction. Results: The local control rates at 2 years post-RT based on pre-treatment CT evaluation were 88% for low pre-treatment risk profile patients (95% CI: 66-96%) and 34% (95% CI: 19-50%) for high pre-treatment risk profile patients (risk ratio 6.583; 95% CI: 2.265-9.129; p = 0.0001). Based on post-treatment CT, the local control rates at 2 years post-RT were 94% for score 1, 67% for score 2, and 10% for score 3 (risk ratio 4.760; 95% CI: 2.278-9.950 p 0.0001). Post-RT CT scores added significant information to the pre-treatment risk profiles on prognosis. Conclusions: Pre-treatment CT risk profiles, as well as post-RT CT evaluation can identify patients, irradiated for laryngeal carcinomas, at high risk for developing local failure. When the post-RT CT score is available, it proves to be an even better prognosticator than the pre-treatment CT-risk profile

  18. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches.

    Directory of Open Access Journals (Sweden)

    Rania M Nada

    Full Text Available Superimposition of serial Cone Beam Computed Tomography (CBCT scans has become a valuable tool for three dimensional (3D assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16 for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27 for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.

  19. Initial water quantification results using neutron computed tomography

    Science.gov (United States)

    Heller, A. K.; Shi, L.; Brenizer, J. S.; Mench, M. M.

    2009-06-01

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at the Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  20. {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography in the management of adult multisystem Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Obert, Julie [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Vercellino, Laetitia [Assistance Publique-Hopitaux de Paris, Service de Medecine Nucleaire, Hopital Saint-Louis, Paris (France); Van der Gucht, Axel [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Medecine Nucleaire, Hopital Saint-Louis, Paris (France); De Margerie-Mellon, Constance [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Radiologie, Hopital Saint-Louis, Paris (France); Bugnet, Emmanuelle; Lorillon, Gwenael [Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Chevret, Sylvie [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Biostatistique et Information Medicale, Hopital Saint-Louis, Paris (France); Biostatistics and Clinical Epidemiology Research Team, U1153 CRESS, Paris (France); Tazi, Abdellatif [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Biostatistics and Clinical Epidemiology Research Team, U1153 CRESS, Paris (France)

    2017-04-15

    The standard evaluation of multisystem Langerhans cell histiocytosis (LCH) includes a clinical evaluation, laboratory tests and a skeleton/skull X-ray survey, with chest high-resolution computed tomography (HRCT) in the case of pulmonary involvement. Preliminary reports suggest that {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography ({sup 18}F-FDG PET-CT) may be useful for evaluating patients with LCH. Fourteen consecutive adult patients with multisystem LCH were included in this retrospective study, and were evaluated using standard procedures and {sup 18}F-FDG PET-CT. The two sets of findings were compared both at baseline and during follow-up. Serial HRCT and pulmonary function tests were used to evaluate outcome in patients with lung involvement. At the baseline evaluation, PET-CT identified every LCH localization found with the standard evaluation (except a mild cecum infiltration). PET-CT showed additional lesions in seven patients, mostly involving bones, and differentiated inactive from active lesions. Thyroid {sup 18}F-FDG uptake was identified in three cases. No pituitary stalk {sup 18}F-FDG uptake was observed in patients with pituitary LCH. Only 3/12 (25 %) patients with pulmonary LCH displayed moderate pulmonary {sup 18}F-FDG uptake. During follow-up, variations (≥50 % of maximum standardized uptake) in bone {sup 18}F-FDG uptake intensity were correlated with disease state and response to treatment. The absence of lung {sup 18}F-FDG uptake did not preclude lung function improvement after treatment. Except for cases with pulmonary and pituitary involvement, {sup 18}F-FDG PET-CT could replace the standard evaluation for staging of adult patients with multisystem LCH. Serial PET-CT scans are useful for evaluating treatment responses, particularly in cases with bone LCH involvement. (orig.)

  1. Experience with computed transmission tomography of the heart in vivo

    International Nuclear Information System (INIS)

    Carlsson, E.; Lipton, M.J.; Skioeldebrand, C.G.; Berninger, W.H.; Redington, R.W.

    1980-01-01

    Cardiac computed tomography in its present form provides useful information about the heart for clinical use in patients with heart disease and for investigative work in such patients and living animals. Its great reconstructive power and unmatched density resolution are particularly advantageous in the study of ischemic heart disease. Because of its non-invasive character cardiac computed tomography has the potential of becoming an effective screening tool for large numbers of patients with suspected or known coronary heart desiase. Other cardiac conditions such as valve disease and congenital lesions can also be examined with high diagnostic yield. However presently available scanners suffer from low repetion rate, long scan times and the fact that only one transverse cardiac level at a time can be obtained. The development which must be accomplished in order to eliminate these weaknesses is technically feasible. The availability of a dynamic cardiac scanner would greatly benefit the treatment of patients with heart disease and facilitate the inquiry into the pathophysiology of such diseases. (orig.) [de

  2. Incidental findings on cone beam computed tomography scans in cleft lip and palate patients

    NARCIS (Netherlands)

    Kuijpers, M.A.R.; Pazera, A.; Admiraal, R.J.C.; Berge, S.J.; Vissink, A.; Pazera, P.

    2014-01-01

    OBJECTIVES: Cone beam computed tomography (CBCT) is frequently used in treatment planning for alveolar bone grafting (ABG) and orthognathic surgery in patients with cleft lip and palate (CLP). CBCT images may depict coincident findings. The aim of this study was to assess the prevalence of

  3. Individualized treatment of craniovertebral junction malformation guided by intraoperative computed tomography.

    Science.gov (United States)

    Li, Lianfeng; Wang, Peng; Chen, LiFeng; Ma, Xiaodong; Bu, Bo; Yu, Xinguang

    2012-04-01

    This study was designed to report our preliminary experience of intraoperative computed tomography (iCT) using a mobile scanner with integrated neuronavigation system (NNS). The objective of this study was to assess the feasibility and potential utility of iCT with integrated NNS in individualized treatment of craniovertebral junction malformation (CVJM). The surgical management of congenital craniovertebral anomalies is complex due to the relative difficulty in accessing the region, critical relationships of neurovascular structures, and the intricate biomechanical issues involved. We reported our first 19 complex CVJM cases including 11 male and 8 female patients from January, 2009 to June, 2009 (mean age, 33.9 y; age range, 13 to 58 y). A sliding gantry 40-slice CT scanner was installed in a preexisting operating room. Image data was transferred directly from the scanner into the NNS using an automated registration system. We applied this technology to transoral odontoidectomy in 17 patients. Moreover, with the extra help of iCT integrated with NNS, odontoidectomy through posterior midline approach, and transoral atlantal lateral mass resection were, for the first time, performed for treatment of complex CVJM. NNS was found to correlate well with the intraoperative findings, and the recalibration was uneven in all cases with an accuracy of 1.6 mm (1.6: 1.2 to 2.0). All patients were clinically evaluated by Nurick grade criteria, and neurological deficits were monitored after 3 months of surgery. Fifteen patients (79%) were improved by at least 1 Nurick grade, whereas the grade did not change in 4 patients (21%). iCT scanning with integrated NNS was both feasible and beneficial for the surgical management of complex CVJM. In this unusual patient population, the technique seemed to be valuable in negotiating complex anatomy and achieving a safe and predictable decompression.

  4. Multislice helical computed tomography in the evaluation of lumbar spine diseases

    International Nuclear Information System (INIS)

    Rosemberg, Laercio Alberto; Rios, Adriana Martins; Almeida, Milena Oliveira; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao

    2003-01-01

    Multislice computed tomography has advantages in comparison to conventional computer tomography such as reduction in study time, lower radiation dose, fewer metal artifacts and high quality multiplanar reformatting and three-dimensional reconstructions. We reviewed approximately 300 lumbar spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms traumatic injuries, spondylolysis and postoperative changes. In the majority of the cases the high quality multiplanar reformatted and volume reconstructions of multislice computed tomography allowed better evaluation of the lesions, particularly in the cases of complex anatomy (author)

  5. Influence of computer tomography on radiological diagnostics of malignant tumors

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, P.; Glueck, E.; Siems, H.

    1981-01-01

    A survey is presented of the present status of cancer diagnostics in the following organs and organ systems: neurocranium, visceral cranium and base of skull, larynx and thyroid, thorax, pancreas, retroperitoneum, kidneys and adrenal glands, pelvis, and skeletal system. The rank of computer tomography is compared with those of other examination techniques.

  6. The history of computed tomography

    International Nuclear Information System (INIS)

    Bull, J.

    1980-01-01

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ) [de

  7. Computed tomography-based subclassification of chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Dirksen, Asger; Wille, Mathilde M W

    2016-01-01

    Computed tomography (CT) is an obvious modality for subclassification of COPD. Traditionally, the pulmonary involvement of chronic obstructive pulmonary disease (COPD) in smokers is understood as a combination of deleterious effects of smoking on small airways (chronic bronchitis and small airways...... observed in COPD are subtle. Furthermore, recent results indicate that emphysema may also be the essential pathophysiologic mechanism behind the airflow limitation of COPD. The definition of COPD excludes bronchiectasis as a symptomatic subtype of COPD, and CT findings in chronic bronchitis...... and exacerbations of COPD are rather unspecific. This leaves emphysema as the most obvious candidate for subclassification of COPD. Both chest radiologists and pulmonary physicians are quite familiar with the appearance of various patterns of emphysema on HRCT, such as centrilobular, panlobular, and paraseptal...

  8. Morphometric analysis - Cone beam computed tomography to predict bone quality and quantity.

    Science.gov (United States)

    Hohlweg-Majert, B; Metzger, M C; Kummer, T; Schulze, D

    2011-07-01

    Modified quantitative computed tomography is a method used to predict bone quality and quantify the bone mass of the jaw. The aim of this study was to determine whether bone quantity or quality was detected by cone beam computed tomography (CBCT) combined with image analysis. MATERIALS AND PROCEDURES: Different measurements recorded on two phantoms (Siemens phantom, Comac phantom) were evaluated on images taken with the Somatom VolumeZoom (Siemens Medical Solutions, Erlangen, Germany) and the NewTom 9000 (NIM s.r.l., Verona, Italy) in order to calculate a calibration curve. The spatial relationships of six sample cylinders and the repositioning from four pig skull halves relative to adjacent defined anatomical structures were assessed by means of three-dimensional visualization software. The calibration curves for computer tomography (CT) and cone beam computer tomography (CBCT) using the Siemens phantom showed linear correlation in both modalities between the Hounsfield Units (HU) and bone morphology. A correction factor for CBCT was calculated. Exact information about the micromorphology of the bone cylinders was only available using of micro computer tomography. Cone-beam computer tomography is a suitable choice for analysing bone mass, but, it does not give any information about bone quality. 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)

  10. Diagnosis of dementia with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Jagust, W.J.; Budinger, T.F.; Reed, B.R.

    1987-01-01

    Single photon emission computed tomography is a practical modality for the study of physiologic cerebral activity in vivo. We utilized single photon emission computed tomography and N-isopropyl-p-iodoamphetamine iodine 123 to evaluate regional cerebral blood flow in nine patients with Alzheimer's disease (AD), five healthy elderly control subjects, and two patients with multi-infarct dementia. We found that all subjects with AD demonstrated flow deficits in temporoparietal cortex bilaterally, and that the ratio of activity in bilateral temporoparietal cortex to activity in the whole slice allowed the differentiation of all patients with AD from both the controls and from the patients with multi-infarct dementia. Furthermore, this ratio showed a strong correlation with disease severity in the AD group. Single photon emission computed tomography appears to be useful in the differential diagnosis of dementia and reflects clinical features of the disease

  11. F-18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Appearance of Extramedullary Hematopoesis in a Case of Primary Myelofibrosis

    Science.gov (United States)

    Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    A 44-year-old female with known primary myelofibrosis presented with shortness of breath. High Resolution Computed Tomography thorax revealed large heterogeneously enhancing extraparenchymal soft tissue density mass involving bilateral lung fields. F-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography revealed mildly FDG avid soft tissue density mass with specks of calcification involving bilateral lung fields, liver, and spleen. Subsequent histopathologic evaluation from the right lung mass was suggestive of extramedullary hematopoesis. PMID:28533647

  12. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  13. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    Energy Technology Data Exchange (ETDEWEB)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients.

  14. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    International Nuclear Information System (INIS)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients

  15. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji [Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2015-03-15

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  16. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    International Nuclear Information System (INIS)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji

    2015-01-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  17. Comparing staging by positron emission tomography with contrast-enhanced computed tomography and by pathology in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Qualliotine, J R; Mydlarz, W K; Chan, J Y K; Zhou, X; Wang, H; Agrawal, N

    2015-12-01

    This study aimed to evaluate the ability of positron emission tomography with contrast-enhanced computed tomography to correctly stage head and neck squamous cell carcinomas, in comparison with pathological staging. Positron emission tomography computed tomography was used to determine the tumour-node-metastasis classification and overall cancer stage in 85 head and neck squamous cell carcinoma patients who underwent pre-operative imaging using this modality and primary surgery between July 2010 and January 2013. Staging by positron emission tomography computed tomography was retrospectively compared with staging using pathological specimens. Agreement between imaging stage and pathological stage was examined by univariate and multivariate analysis both overall and for each primary tumour site. This imaging modality was 87.5 per cent sensitive and 44.8 per cent specific in identifying regional cervical metastases, and had false positive and false negative rates of 18.8 per cent and 8.2 per cent, respectively. The positive predictive and negative predictive values were 75.4 per cent and 65.0 per cent, respectively. Univariate and multivariate analyses revealed a significant agreement between positron emission tomography computed tomography and pathological node classification in older patients and for the oral cavity primary tumour site. There was significant agreement between both methods in the overall classification only for tumours classified as T3 or greater. Positron emission tomography computed tomography should be used with caution for the pre-operative staging of head and neck cancers because of its high false positive and false negative rates.

  18. Single-photon emission computed tomography in human immunodeficiency virus encephalopathy: A preliminary report

    International Nuclear Information System (INIS)

    Masdeu, J.C.; Yudd, A.; Van Heertum, R.L.; Grundman, M.; Hriso, E.; O'Connell, R.A.; Luck, D.; Camli, U.; King, L.N.

    1991-01-01

    Depression or psychosis in a previously asymptomatic individual infected with the human immunodeficiency virus (HIV) may be psychogenic, related to brain involvement by the HIV or both. Although prognosis and treatment differ depending on etiology, computed tomography (CT) and magnetic resonance imaging (MRI) are usually unrevealing in early HIV encephalopathy and therefore cannot differentiate it from psychogenic conditions. Thirty of 32 patients (94%) with HIV encephalopathy had single-photon emission computed tomography (SPECT) findings that differed from the findings in 15 patients with non-HIV psychoses and 6 controls. SPECT showed multifocal cortical and subcortical areas of hypoperfusion. In 4 cases, cognitive improvement after 6-8 weeks of zidovudine (AZT) therapy was reflected in amelioration of SPECT findings. CT remained unchanged. SPECT may be a useful technique for the evaluation of HIV encephalopathy

  19. Direct estimation of human trabecular bone stiffness using cone beam computed tomography.

    Science.gov (United States)

    Klintström, Eva; Klintström, Benjamin; Pahr, Dieter; Brismar, Torkel B; Smedby, Örjan; Moreno, Rodrigo

    2018-04-10

    The aim of this study was to evaluate the possibility of estimating the biomechanical properties of trabecular bone through finite element simulations by using dental cone beam computed tomography data. Fourteen human radius specimens were scanned in 3 cone beam computed tomography devices: 3-D Accuitomo 80 (J. Morita MFG., Kyoto, Japan), NewTom 5 G (QR Verona, Verona, Italy), and Verity (Planmed, Helsinki, Finland). The imaging data were segmented by using 2 different methods. Stiffness (Young modulus), shear moduli, and the size and shape of the stiffness tensor were studied. Corresponding evaluations by using micro-CT were regarded as the reference standard. The 3-D Accuitomo 80 (J. Morita MFG., Kyoto, Japan) showed good performance in estimating stiffness and shear moduli but was sensitive to the choice of segmentation method. NewTom 5 G (QR Verona, Verona, Italy) and Verity (Planmed, Helsinki, Finland) yielded good correlations, but they were not as strong as Accuitomo 80 (J. Morita MFG., Kyoto, Japan). The cone beam computed tomography devices overestimated both stiffness and shear compared with the micro-CT estimations. Finite element-based calculations of biomechanics from cone beam computed tomography data are feasible, with strong correlations for the Accuitomo 80 scanner (J. Morita MFG., Kyoto, Japan) combined with an appropriate segmentation method. Such measurements might be useful for predicting implant survival by in vivo estimations of bone properties. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  1. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  2. Incidental findings on cone beam computed tomography scans in cleft lip and palate patients

    NARCIS (Netherlands)

    Kuijpers, Mette A. R.; Pazera, Andrzej; Admiraal, Ronald J.; Berge, Stefaan J.; Vissink, Arjan; Pazera, Pawel

    Cone beam computed tomography (CBCT) is frequently used in treatment planning for alveolar bone grafting (ABG) and orthognathic surgery in patients with cleft lip and palate (CLP). CBCT images may depict coincident findings. The aim of this study was to assess the prevalence of incidental findings

  3. FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography-X-ray computed tomography.

    Science.gov (United States)

    Ale, Angelique; Ermolayev, Vladimir; Herzog, Eva; Cohrs, Christian; de Angelis, Martin Hrabé; Ntziachristos, Vasilis

    2012-06-01

    The development of hybrid optical tomography methods to improve imaging performance has been suggested over a decade ago and has been experimentally demonstrated in animals and humans. Here we examined in vivo performance of a camera-based hybrid fluorescence molecular tomography (FMT) system for 360° imaging combined with X-ray computed tomography (XCT). Offering an accurately co-registered, information-rich hybrid data set, FMT-XCT has new imaging possibilities compared to stand-alone FMT and XCT. We applied FMT-XCT to a subcutaneous 4T1 tumor mouse model, an Aga2 osteogenesis imperfecta model and a Kras lung cancer mouse model, using XCT information during FMT inversion. We validated in vivo imaging results against post-mortem planar fluorescence images of cryoslices and histology data. Besides offering concurrent anatomical and functional information, FMT-XCT resulted in the most accurate FMT performance to date. These findings indicate that addition of FMT optics into the XCT gantry may be a potent upgrade for small-animal XCT systems.

  4. Efficacy of 3D-positron emission tomography/computed tomography for upper abdomen.

    Science.gov (United States)

    Murakami, Koji; Nakahara, Tadaki

    2014-04-01

    Recent advancement in computed tomography (CT) enables us to obtain high spatial resolution image and made it possible to construct extensive high-definition three-dimensional (3D) images. But a lack of contrast resolution in CT alone is still remained problem. Meanwhile, as fluorodeoxyglucose-positron emission tomography (PET) can visualize tumors in high contrast, we can create 3D images fusing the accumulation in tumors on PET/CT images. Such images can play the role of a "map of body" which makes it easy to understand the anatomical information before surgery. We also try to evaluate segmental liver function by using PET/CT fusion images. By using (11) C-methionine PET/contrast-enhanced CT, superior image quality compared to single photon emission computed tomography/CT can be obtained. CT, especially with contrast enhancement for obtaining anatomical imaging information plus PET for obtaining functional imaging information is a highly compatible combination, and adding these two types information will further increase clinical usefulness. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  5. Cervical lymph node hyperplasia on [18F]-fluorodeoxyglucose positron emission tomography/computed tomography scan after treatment of children and adolescents with malignant lymphoma

    International Nuclear Information System (INIS)

    Hu, Ying-Ying; Zhang, Xu; Long, Wen; Lin, Xiao-Ping; Zhang, Ya-Rui; Li, Yuan-Hua; Xiao, Zi-Zheng; Zheng, Rong-Liang; Liang, Pei-Yan; Fan, Wei

    2015-01-01

    Highlights: • Cervical lymph node hyperplasia is a benign processes. • Lymph node hyperplasia found in treated children and adolescents with lymphoma. • We define imaging manifestations of cervical lymph node hyperplasia in PET/CT. • Awareness of lymph node hyperplasia avoid invasive procedures and over-treatment. - Abstract: Purpose: To define imaging manifestations and clinical prognosis of cervical lymph node hyperplasia using [ 18 F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning after treatment of children and adolescents with malignant lymphoma. Methods: Children and adolescent patients with malignant lymphoma who had high FDG uptake in their cervical lymph nodes via PET/CT after treatment, which was not due to tumor recurrence or residue, were retrospectively analyzed. Results: Twenty-seven patients with a median age of 12 years were included; 11 had Hodgkin's disease and 16 had non-Hodgkin's lymphoma. The time from PET/CT scan to completion of therapy was 1–36 months, 85.2% (23/27) of which took place within 12 months. Three patients had confirmed lymph node follicular hyperplasia by biopsy, while all 27 patients achieved disease-free survival during the follow-up period. The maximum standardized uptake values (SUV max ) of cervical lymph nodes were 2.2–16.2 and the maximum short axis ranged from 0.3 to 1.2 cm. Cervical lymph node hyperplasia was noted in neck levels I–V, and neck level II bilaterally had the highest incidence (100%). Bilateral cervical lymph node hyperplasia was symmetrical in terms of both the SUV max and affected locations. Thymic hyperplasia and nasopharyngeal lymphoid hyperplasia were both observed in 24 patients (88.9%). There was no relationship in terms of the SUV max between cervical lymph nodes and thymic tissue, cervical nodes or nasopharyngeal lymphoid tissue. Conclusion: Cervical lymph node hyperplasia with high FDG uptake on PET/CT scans found after treating

  6. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  7. Evaluation of safe surgical treatment of peritonsillar abscess using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Kasumi; Aramaki, Hajime; Arai, Yasuko; Uchimura, Kanako; Okabe, Kunihiko; Nishida, Motoko; Yoda, Keiko [Tokyo Women' s Medical Coll. (Japan). Daini Hospital

    2002-03-01

    With the development of new antimicrobial agents, the incidence of peritonsillar abscess (PTA) is on the decline. PTA is still often encountered in general practice, however, where it requires immediate diagnosis and treatment. Because the internal carotid artery runs medially to the medial parapharyngeal space, damage to nearby vascular or other structures is a surgical risk of PTA. We used contrast computed tomography (CT) from PTA patients to investigate the anatomical relationship between the abscess and parapharyngeal space, and to determine safe surgical sites. We observed 31 patients with PTA, 19 men and 12 women, between February 1997 and April 1999, all examined by contrast CT and undergoing drainage or incision. The average age was 30.7 years (range: 12-54 years). The abscess was on the right side in 20 cases and on the left side in 11. We determined the sites of the abscess and carotid artery, internal jugular vein, and surrounding soft tissue density area including nerves in the parapharyngeal space based on the angle and distance from recognizable anatomical structures in CT scans. The anterior margin of the parapharyngeal space was 29{+-}5 mm posterior from the upper posterior alveolar margin. The medial margin of that space was at 15{+-}2 deg laterally from the midline of the incisors, and 24{+-}4 mm laterally from the midline sagittal plane. The internal carotid artery was located medially to the parapharyngeal space, running on the sagittal plane containing the upper posterior alveolar margin. The distance from the anterior margin of the parapharyngeal space to the posterior wall of the PTA was 9{+-}4 mm, and the distance to the anterior wall of the abscess (including the pharyngeal mucosa) was 31{+-}5 cm. The relationship between the upper posterior alveolar margin and midline sagittal plane was useful for determining the site of the parapharyngeal space. Because the internal carotid artery is located on the same sagittal plane as the upper

  8. Evaluation of safe surgical treatment of peritonsillar abscess using computed tomography

    International Nuclear Information System (INIS)

    Ishii, Kasumi; Aramaki, Hajime; Arai, Yasuko; Uchimura, Kanako; Okabe, Kunihiko; Nishida, Motoko; Yoda, Keiko

    2002-01-01

    With the development of new antimicrobial agents, the incidence of peritonsillar abscess (PTA) is on the decline. PTA is still often encountered in general practice, however, where it requires immediate diagnosis and treatment. Because the internal carotid artery runs medially to the medial parapharyngeal space, damage to nearby vascular or other structures is a surgical risk of PTA. We used contrast computed tomography (CT) from PTA patients to investigate the anatomical relationship between the abscess and parapharyngeal space, and to determine safe surgical sites. We observed 31 patients with PTA, 19 men and 12 women, between February 1997 and April 1999, all examined by contrast CT and undergoing drainage or incision. The average age was 30.7 years (range: 12-54 years). The abscess was on the right side in 20 cases and on the left side in 11. We determined the sites of the abscess and carotid artery, internal jugular vein, and surrounding soft tissue density area including nerves in the parapharyngeal space based on the angle and distance from recognizable anatomical structures in CT scans. The anterior margin of the parapharyngeal space was 29±5 mm posterior from the upper posterior alveolar margin. The medial margin of that space was at 15±2 deg laterally from the midline of the incisors, and 24±4 mm laterally from the midline sagittal plane. The internal carotid artery was located medially to the parapharyngeal space, running on the sagittal plane containing the upper posterior alveolar margin. The distance from the anterior margin of the parapharyngeal space to the posterior wall of the PTA was 9±4 mm, and the distance to the anterior wall of the abscess (including the pharyngeal mucosa) was 31±5 cm. The relationship between the upper posterior alveolar margin and midline sagittal plane was useful for determining the site of the parapharyngeal space. Because the internal carotid artery is located on the same sagittal plane as the upper posterior

  9. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  10. Prior-based artifact correction (PBAC) in computed tomography

    International Nuclear Information System (INIS)

    Heußer, Thorsten; Brehm, Marcus; Ritschl, Ludwig; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. Methods: The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. Results: The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. Conclusions: The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data

  11. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  12. Computed tomography of thymic abnormalities: review of 10 patients

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Brito Pacheco, E.M. de; Cazerta, N.M.G.; Silva, M.J.G. da

    1990-01-01

    Chest radiographs and computed tomographic scans of the mediastinum were correlated with pathologic findings of the thymus following thymectomy in 10 patients with thymic disease. There were five patients with thymoma, four with thymic hiperplasia and one with benign thymic cyst. Computed tomography shoud be the imaging method of choice following plain chest radiographs when a suspect thymic abnormality requires further evaluation. Recognition of variations in the normal location, size, shape and density of the thymus prevents misinterpretation as abnormal mediastinal mass. Furthermore, knowledge of the normal computed tomography appearance has proved helpful in evaluating thymic abnormalities. (author)

  13. Cranial computed tomography in infantile spasms

    International Nuclear Information System (INIS)

    Howitz, P.; Neergaard, K.; Pedersen, H.

    1990-01-01

    Out of 109 children with infantile spasms (IS), prospectively tested during the years 1976 to 1979 in Denmark, 52 children were examined by cranial computed tomography (CT). The classification of IS into cryptogenic (CR), symptomatic (SY) and doubtful (DO) was done clinically without considering the CT-finding. Sixty per cent of the scannings were abnormal. Only 6/30 (20%) of the children in ACTH treatment were found to develop cerebral atrophy which means that this finding is not an obligatory side-effect of ACTH treatment of children with IS. Normal CT-findings were found in 50% of the CR and 50% of the SY + DO-groups, and could not be used as a prognostic tool for estimating the mental development. This was also the case for children with cerebral atrophy. Abnormal CT-findings (minus atrophy) were highly correlated to the group with clinical symptoms and indicate an extremely unsatisfying long-term mental prognosis. CT-scanning is a valuable tool for the examination of clearing children with infantile spasms. (authors)

  14. Comparison of hand and semiautomatic tracing methods for creating maxillofacial artificial organs using sequences of computed tomography (CT) and cone beam computed tomography (CBCT) images.

    Science.gov (United States)

    Szabo, Bence T; Aksoy, Seçil; Repassy, Gabor; Csomo, Krisztian; Dobo-Nagy, Csaba; Orhan, Kaan

    2017-06-09

    The aim of this study was to compare the paranasal sinus volumes obtained by manual and semiautomatic imaging software programs using both CT and CBCT imaging. 121 computed tomography (CT) and 119 cone beam computed tomography (CBCT) examinations were selected from the databases of the authors' institutes. The Digital Imaging and Communications in Medicine (DICOM) images were imported into 3-dimensonal imaging software, in which hand mode and semiautomatic tracing methods were used to measure the volumes of both maxillary sinuses and the sphenoid sinus. The determined volumetric means were compared to previously published averages. Isometric CBCT-based volume determination results were closer to the real volume conditions, whereas the non-isometric CT-based volume measurements defined coherently lower volumes. By comparing the 2 volume measurement modes, the values gained from hand mode were closer to the literature data. Furthermore, CBCT-based image measurement results corresponded to the known averages. Our results suggest that CBCT images provide reliable volumetric information that can be depended on for artificial organ construction, and which may aid the guidance of the operator prior to or during the intervention.

  15. Effects on mortality, treatment, and time management as a result of routine use of total body computed tomography in blunt high-energy trauma patients.

    Science.gov (United States)

    van Vugt, Raoul; Kool, Digna R; Deunk, Jaap; Edwards, Michael J R

    2012-03-01

    Currently, total body computed tomography (TBCT) is rapidly implemented in the evaluation of trauma patients. With this review, we aim to evaluate the clinical implications-mortality, change in treatment, and time management-of the routine use of TBCT in adult blunt high-energy trauma patients compared with a conservative approach with the use of conventional radiography, ultrasound, and selective computed tomography. A literature search for original studies on TBCT in blunt high-energy trauma patients was performed. Two independent observers included studies concerning mortality, change of treatment, and/or time management as outcome measures. For each article, relevant data were extracted and analyzed. In addition, the quality according to the Oxford levels of evidence was assessed. From 183 articles initially identified, the observers included nine original studies in consensus. One of three studies described a significant difference in mortality; four described a change of treatment in 2% to 27% of patients because of the use of TBCT. Five studies found a gain in time with the use of immediate routine TBCT. Eight studies scored a level of evidence of 2b and one of 3b. Current literature has predominantly suboptimal design to prove terminally that the routine use of TBCT results in improved survival of blunt high-energy trauma patients. TBCT can give a change of treatment and improves time intervals in the emergency department as compared with its selective use.

  16. Esthetic considerations for the treatment of the edentulous maxilla based on current informatic alternatives: a case report.

    Science.gov (United States)

    Rodríguez-Tizcareño, Mario H; Barajas, Lizbeth; Pérez-Gásque, Marisol; Gómez, Salvador

    2012-06-01

    This report presents a protocol used to transfer the virtual treatment plan data to the surgical and prosthetic reality and its clinical application, bone site augmentation with computer-custom milled bovine bone graft blocks to their ideal architecture form, implant insertion based on image-guided stent fabrication, and the restorative manufacturing process through computed tomography-based software programs and navigation systems and the computer-aided design and manufacturing techniques for the treatment of the edentulous maxilla.

  17. Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans

    Science.gov (United States)

    2017-07-13

    Computed Tomography Scans by Autumn R Kulaga, Kathryn L Loftis, and Eric Murray Approved for public release; distribution is...Army Research Laboratory Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans by Autumn R Kulaga...Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  18. Individualized Nonadaptive and Online-Adaptive Intensity-Modulated Radiotherapy Treatment Strategies for Cervical Cancer Patients Based on Pretreatment Acquired Variable Bladder Filling Computed Tomography Scans

    International Nuclear Information System (INIS)

    Bondar, M.L.; Hoogeman, M.S.; Mens, J.W.; Quint, S.; Ahmad, R.; Dhawtal, G.; Heijmen, B.J.

    2012-01-01

    Purpose: To design and evaluate individualized nonadaptive and online-adaptive strategies based on a pretreatment established motion model for the highly deformable target volume in cervical cancer patients. Methods and Materials: For 14 patients, nine to ten variable bladder filling computed tomography (CT) scans were acquired at pretreatment and after 40 Gy. Individualized model-based internal target volumes (mbITVs) accounting for the cervix and uterus motion due to bladder volume changes were generated by using a motion-model constructed from two pretreatment CT scans (full and empty bladder). Two individualized strategies were designed: a nonadaptive strategy, using an mbITV accounting for the full-range of bladder volume changes throughout the treatment; and an online-adaptive strategy, using mbITVs of bladder volume subranges to construct a library of plans. The latter adapts the treatment online by selecting the plan-of-the-day from the library based on the measured bladder volume. The individualized strategies were evaluated by the seven to eight CT scans not used for mbITVs construction, and compared with a population-based approach. Geometric uniform margins around planning cervix–uterus and mbITVs were determined to ensure adequate coverage. For each strategy, the percentage of the cervix–uterus, bladder, and rectum volumes inside the planning target volume (PTV), and the clinical target volume (CTV)-to-PTV volume (volume difference between PTV and CTV) were calculated. Results: The margin for the population-based approach was 38 mm and for the individualized strategies was 7 to 10 mm. Compared with the population-based approach, the individualized nonadaptive strategy decreased the CTV-to-PTV volume by 48% ± 6% and the percentage of bladder and rectum inside the PTV by 5% to 45% and 26% to 74% (p < 0.001), respectively. Replacing the individualized nonadaptive strategy by an online-adaptive, two-plan library further decreased the percentage of

  19. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  20. Diagnostic accuracy of (18) F-methylcholine positron emission tomography/computed tomography for intra- and extrahepatic hepatocellular carcinoma.

    Science.gov (United States)

    Bieze, Matthanja; Klümpen, Heinz-Josef; Verheij, Joanne; Beuers, Ulrich; Phoa, Saffire S K S; van Gulik, Thomas M; Bennink, Roelof J

    2014-03-01

    Diagnosis of hepatocellular carcinoma (HCC) primarily involves imaging. The aim of this study was to assess the accuracy of (18) F-fluorocholine ((18) F-FCH) positron emission tomography (PET) for detection of HCC and evaluation of extent of disease. Patients with HCC >1 cm were included between 2009 and July 2011, and follow-up closed in February 2013. Diagnosis was based on American Association for the Study of Liver Diseases criteria, and all patients underwent (18) F-FCH PET/computed tomography (CT) at baseline before treatment, 6 underwent a second PET/CT posttreatment, and 1 a third during follow-up. Whole-body PET and low-dose CT imaging were performed 15 minutes after (18) F-FCH injection. Evaluation of imaging was done with standardized uptake value (SUV) ratios: SUV maximum of the lesion divided by the SUV mean of surrounding tissue. Statistical analyses included descriptive analyses, receiver operating characteristic curve, McNemar's test, and Kaplan-Meier's test at 5% level of significance. Twenty-nine patients revealed 53 intrahepatic lesions. In 48 of 53 lesions, (18) F-FCH PET was positive (SUVratio , 1.95 ± 0.66; sensitivity, 88%; specificity, 100%). PET/CT showed uptake in 18 extrahepatic lesions and no uptake in 3 lesions affirmed non-HCC lesions; all lesions were confirmed with additional investigation (accuracy, 100%). In 17 of 29 patients, additional lesions were found on PET/CT imaging, with implications for treatment in 15 patients. Posttreatment PET/CT showed identical results, compared with standard treatment evaluation. This study shows additional value of (18) F-FCH PET/CT for patients with HCC. (18) F-FCH PET/CT has implications for staging, management, and treatment evaluation because of accurate assessment of extrahepatic disease. © 2014 by the American Association for the Study of Liver Diseases.

  1. The role of positron emission tomography/computed tomography imaging with radiolabeled choline analogues in prostate cancer.

    Science.gov (United States)

    Navarro-Pelayo Láinez, M M; Rodríguez-Fernández, A; Gómez-Río, M; Vázquez-Alonso, F; Cózar-Olmo, J M; Llamas-Elvira, J M

    2014-11-01

    prostate cancer is the most frequent solid malignant tumor in Western Countries. Positron emission tomography/x-ray computed tomography imaging with radiolabeled choline analogues is a useful tool for restaging prostate cancer in patients with rising prostate-specific antigen after radical treatment (in whom conventional imaging techniques have important limitations) as well as in the initial assessment of a selected group of prostate cancer patients. For this reason a literature review is necessary in order to evaluate the usefulness of this imaging test for the diagnosis and treatment of prostate cancer. a MEDLINE (PubMed way) literature search was performed using the search parameters: «Prostate cancer» and «Choline-PET/CT». Other search terms were «Biochemical failure» and/or «Staging» and/or «PSA kinetics». English and Spanish papers were selected; original articles, reviews, systematic reviews and clinical guidelines were included. according to available data, radiolabeled choline analogues plays an important role in the management of prostate cancer, especially in biochemical relapse because technique accuracy is properly correlated with prostate-specific antigen values and kinetics. Although is an emerging diagnostic technique useful in treatment planning of prostate cancer, final recommendations have not been submitted. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.

  2. X-ray Computed Tomography of Ultralightweight Metals

    National Research Council Canada - National Science Library

    Winter, John

    2001-01-01

    .... To date, the imaging capabilities of x-ray computed tomography have not been generally employed to nondestructively examine the internal structure of the products formed by these various processes...

  3. Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Staging of Patients with Non-Small Cell Lung Cancer without Mediastinal Involvement at Positron Emission Tomography-Computed Tomography

    DEFF Research Database (Denmark)

    Naur, Therese Maria Henriette; Konge, Lars; Clementsen, Paul Frost

    2017-01-01

    BACKGROUND: Staging of lung cancer is essential to the treatment, which is curative only in cases of localized disease. Previous studies have suggested that endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unnecessary when positron emission tomography-computed tomog...

  4. Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    This publication presents a harmonized approach to quality assurance in the field of computed tomography applied to both diagnostics and therapy. It gives a careful analysis of the principles and specific instructions that can be used for a quality assurance programme for optimal performance and reduced patient dose in diagnostic radiology. In some cases, radiotherapy programmes are making a transition from 2-D to 3-D radiotherapy, a complex process which critically depends on accurate treatment planning. In this respect, the authors also provide detailed information about the elements needed for quality assurance testing, including those relating to accurate patient characterization as needed for radiotherapy treatment planning.

  5. Computed tomography (CT) and diastematomyelia's diagnosis

    International Nuclear Information System (INIS)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S.; Barros, A.P. de

    1982-01-01

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized. (Author) [pt

  6. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...

  7. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  8. Optical computed tomography for imaging the breast: first look

    Science.gov (United States)

    Grable, Richard J.; Ponder, Steven L.; Gkanatsios, Nikolaos A.; Dieckmann, William; Olivier, Patrick F.; Wake, Robert H.; Zeng, Yueping

    2000-07-01

    The purpose of the study is to compare computed tomography optical imaging with traditional breast imaging techniques. Images produced by computed tomography laser mammography (CTLMTM) scanner are compared with images obtained from mammography, and in some cases ultrasound and/or magnetic resonance imaging (MRI). During the CTLM procedure, a near infrared laser irradiates the breast and an array of photodiodes detectors records light scattered through the breast tissue. The laser and detectors rotate synchronously around the breast to acquire a series of slice data along the coronal place. The procedure is performed without any breast compression or optical matching fluid. Cross-sectional slices of the breast are produced using a reconstruction algorithm. Reconstruction based on the diffusion theory is used to produce cross-sectional slices of the breast. Multiple slice images are combined to produce a three dimensional volumetric array of the imaged breast. This array is used to derive axial and sagittal images of the breast corresponding to cranio-caudal and medio-lateral images used in mammography. Over 200 women and 3 men have been scanned in clinical trials. The most obvious features seen in images produced by the optical tomography scanner are vascularization and significant lesions. Breast features caused by fibrocystic changes and cysts are less obvious. Breast density does not appear to be a significant factor in the quality of the image. We see correlation of the optical image structure with that seen with traditional breast imaging techniques. Further testing is being conducted to explore the sensitivity and specificity of optical tomography of the breast.

  9. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  10. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  11. Computed tomography in space-occupying intraspinal processes

    International Nuclear Information System (INIS)

    Proemper, C.; Friedmann, G.

    1983-01-01

    Spinal computed tomography has considerably enhanced differential diagnostic safety in the course of the past two years. It has disclosed new possibilities of indication in the diagnosis of the vertebral column. With the expected improvement in apparatus technology, computed tomography will increasingly replace invasive examination methods. Detailed knowledge of clinical data, classification of the neurological findings, and localisation of the height - as far as possible - are the necessary prerequisites of successful diagnosis. If they are absent, it is recommended to perform myelography followed by secondary CT-myelography. If these preliminary conditions are observed, spinal CT can make outstanding contributions to be diagnosis of slipped disk, of the constricted vertebral canal, as well as tumours, malformations and posttraumatic conditions, postoperative changes and inflammatory processes. (orig.) [de

  12. Soil structure changes evaluated with computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz Fernando

    2010-01-01

    The objective of this work was to evaluate in millimetric scale changes in soil bulk density and porosity, using the gamma-ray computed tomography in soil samples with disturbed structure due to wetting and drying (W-D) cycles. Soil samples with 98.1 cm 3 were sieved using a 2 mm mesh and homogeneously packed in PVC cylinders. Soil samples were submitted to 1, 2, and 3 W-D cycles. Control samples were not submitted to W-D cycles. After repetitions of W-D cycles, soil sample porosity decreased and soil layers became denser. Computed tomography allowed a continuous analysis of soil bulk density and also soil porosity along millimetric (0.08 cm) layers, what cannot be provided by traditional methods used in soil physics. (author)

  13. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  14. Regorafenib effects on human colon carcinoma xenografts monitored by dynamic contrast-enhanced computed tomography with immunohistochemical validation.

    Directory of Open Access Journals (Sweden)

    Clemens C Cyran

    Full Text Available To investigate dynamic contrast-enhanced computed tomography for monitoring the effects of regorafenib on experimental colon carcinomas in rats by quantitative assessments of tumor microcirculation parameters with immunohistochemical validation.Colon carcinoma xenografts (HT-29 implanted subcutaneously in female athymic rats (n = 15 were imaged at baseline and after a one-week treatment with regorafenib by dynamic contrast-enhanced computed tomography (128-slice dual-source computed tomography. The therapy group (n = 7 received regorafenib daily (10 mg/kg bodyweight. Quantitative parameters of tumor microcirculation (plasma flow, mL/100 mL/min, endothelial permeability (PS, mL/100 mL/min, and tumor vascularity (plasma volume, % were calculated using a 2-compartment uptake model. Dynamic contrast-enhanced computed tomography parameters were validated with immunohistochemical assessments of tumor microvascular density (CD-31, tumor cell apoptosis (TUNEL, and proliferation (Ki-67.Regorafenib suppressed tumor vascularity (15.7±5.3 to 5.5±3.5%; p<0.05 and tumor perfusion (12.8±2.3 to 8.8±2.9 mL/100 mL/min; p = 0.063. Significantly lower microvascular density was observed in the therapy group (CD-31; 48±10 vs. 113±25, p<0.05. In regorafenib-treated tumors, significantly more apoptotic cells (TUNEL; 11844±2927 vs. 5097±3463, p<0.05 were observed. Dynamic contrast-enhanced computed tomography tumor perfusion and tumor vascularity correlated significantly (p<0.05 with microvascular density (CD-31; r = 0.84 and 0.66 and inversely with apoptosis (TUNEL; r = -0.66 and -0.71.Regorafenib significantly suppressed tumor vascularity (plasma volume quantified by dynamic contrast-enhanced computed tomography in experimental colon carcinomas in rats with good-to-moderate correlations to an immunohistochemical gold standard. Tumor response biomarkers assessed by dynamic contrast-enhanced computed tomography may be a promising future

  15. Evaluation of hepatic calcifications in cancer patients with ultrasonography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Oehl, S; Rehwald, U; Heckemann, R

    1985-02-01

    Eight patients with metastatic solid tumours had calcified liver metastases. These infiltrates can be demonstrated by plain X-ray pictures, however, they may be differentiated earlier by sonography and computed tomography. Their appearance does not necessarily correlate with the histology or response to treatment. In addition to cases of colorectal malignancy, this unusual finding occurred in association with breast cancer, thyroid and ovarian cancer.

  16. The significance of routine thoracic computed tomography in patients with blunt chest trauma.

    Science.gov (United States)

    Çorbacıoğlu, Seref Kerem; Er, Erhan; Aslan, Sahin; Seviner, Meltem; Aksel, Gökhan; Doğan, Nurettin Özgür; Güler, Sertaç; Bitir, Aysen

    2015-05-01

    The purpose of this study is to investigate whether the use of thoracic computed tomography (TCT) as part of nonselective computed tomography (CT) guidelines is superior to selective CT during the diagnosis of blunt chest trauma. This study was planned as a prospective cohort study, and it was conducted at the emergency department between 2013 and 2014. A total of 260 adult patients who did not meet the exclusion criteria were enrolled in the study. All patients were evaluated by an emergency physician, and their primary surveys were completed based on the Advanced Trauma Life Support (ATLS) principles. Based on the initial findings and ATLS recommendations, patients in whom thoracic CT was indicated were determined (selective CT group). Routine CTs were then performed on all patients. Thoracic injuries were found in 97 (37.3%) patients following routine TCT. In 53 (20%) patients, thoracic injuries were found by selective CT. Routine TCT was able to detect chest injury in 44 (16%) patients for whom selective TCT would not otherwise be ordered based on the EP evaluation (nonselective TCT group). Five (2%) patients in this nonselective TCT group required tube thoracostomy, while there was no additional treatment provided for thoracic injuries in the remaining 39 (15%). In conclusion, we found that the nonselective TCT method was superior to the selective TCT method in detecting thoracic injuries in patients with blunt trauma. Furthermore, we were able to demonstrate that the nonselective TCT method can change the course of patient management albeit at low rates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography.

    Science.gov (United States)

    Benz, Robyn Melanie; Garcia, Meritxell Alzamora; Amsler, Felix; Voigt, Johannes; Fieselmann, Andreas; Falkowski, Anna Lucja; Stieltjes, Bram; Hirschmann, Anna

    2018-01-01

    Phantom-based initial performance assessment of a prototype three-dimensional (3-D) x-ray system and comparison of 3-D tomography with computed tomography (CT) were proposed. A 3-D image quality phantom was scanned with a prototype version of 3-D cone-beam CT imaging implemented on a twin robotic x-ray system using three trajectories (163 deg = table, 188 deg = upright, and 200 deg = side), six tube voltages (60, 70, 81, 90, 100, and 121 kV), and four detector doses (0.348, 0.696, 1.740, and [Formula: see text]). CT was obtained with a clinical protocol. Spatial resolution (line pairs/cm) and soft-tissue-contrast resolution were assessed by two independent readers. Radiation dose was assessed. Descriptive and analysis of variance (ANOVA) ([Formula: see text]) were performed. With 3-D tomography, a maximum of 16 lp/cm was visible and best soft-tissue-contrast resolution was 2 mm at 30 Hounsfield units (HU) for 160 projections. With CT, 10 lp/cm was visible and soft-tissue-contrast resolution was 4 mm at 20 HU. The upright trajectory yielded significantly better spatial resolution and soft tissue contrast, and the side trajectory yielded significantly higher soft tissue contrast than the table trajectory ([Formula: see text]). Radiation dose was higher in 3-D tomography (45 to 704 mGycm) than CT (44 mGycm). Three-dimensional tomography renders overall equal or higher spatial resolution and comparable soft tissue contrast to CT for medium- and high-dose protocols in the side and upright trajectories, but with higher radiation doses.

  18. Computed tomography in orbital fractures and optic nerve trauma

    International Nuclear Information System (INIS)

    Dietrich, U.; Sievers, K.; Feldges, A.; Nau, H.E.

    1990-01-01

    Ten patients with orbital fractures and optic nerve trauma are reported. Fractures of the optic canal could be demonstrated by computed tomography in six cases and fractures of the orbital apex in another three cases. Surgical decompression of the optic canal was performed in seven cases. Computed tomography enhanced decision for surgery in cases of intraorbital haematoma with exophthalmus and narrowing of the canal by bony fragments, especially in those patients presenting with incomplete or progressive visual disturbance. (orig.) [de

  19. Effects of polytetrafluoroethylene treatment and compression on gas diffusion layer microstructure using high-resolution X-ray computed tomography

    Science.gov (United States)

    Khajeh-Hosseini-Dalasm, Navvab; Sasabe, Takashi; Tokumasu, Takashi; Pasaogullari, Ugur

    2014-11-01

    The microstructure of a TGP-H-120 Toray paper gas diffusion layer (GDL) was investigated using high resolution X-ray computed tomography (CT) technique, with a resolution of 1.8 μm and a field of view (FOV) of ∼1.8 × 1.8 mm. The images obtained from the tomography scans were further post processed, and image thresholding and binarization methodologies are presented. The validity of Otsu's thresholding method was examined. Detailed information on bulk porosity and porosity distribution of the GDL at various Polytetrafluoroethylene (PTFE) treatments and uniform/non-uniform compression pressures was provided. A sample holder was designed to investigate the effects of non-uniform compression pressure, which enabled regulating compression pressure between 0, and 3 MPa at a gas channel/current collector rib configuration. The results show the heterogeneous and anisotropic microstructure of the GDL, non-uniform distribution of PTFE, and significant microstructural change under uniform/non-uniform compression. These findings provide useful inputs for numerical models to include the effects of microstructural changes in the study of transport phenomena within the GDL and to increase the accuracy and predictability of cell performance.

  20. Three Dimensional Digital Sieving of Asphalt Mixture Based on X-ray Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chichun Hu

    2017-07-01

    Full Text Available In order to perform three-dimensional digital sieving based on X-ray computed tomography images, the definition of digital sieve size (DSS was proposed, which was defined as the minimum length of the minimum bounding squares of all possible orthographic projections of an aggregate. The corresponding program was developed to reconstruct aggregate structure and to obtain DSS. Laboratory experiments consisting of epoxy-filled aggregate specimens were conducted to investigate the difference between mechanical sieve analysis and the digital sieving technique. It was suggested that concave surface of aggregate was the possible reason for the disparity between DSS and mechanical sieve size. A comparison between DSS and equivalent diameter was also performed. Moreover, the digital sieving technique was adopted to evaluate the gradation of stone mastic asphalt mixtures. The results showed that the closest proximity of the laboratory gradation curve was achieved by calibrated DSS, among gradation curves based on calibrated DSS, un-calibrated DSS and equivalent diameter.

  1. Cranial radiotherapy guided by computed tomography with or without fields conformation in pediatric

    International Nuclear Information System (INIS)

    Fernandez, Diego; Caussa, Lucas; Murina, Patricia; Zunino, Silvia

    2007-01-01

    Many malignancies in children can be cured by radiotherapy, acute toxicity and the significant effect of delayed treatment are worrying for the patient, family and society. Therefore, the end of the pediatric radiotherapy is to maintain or improve the cure rate of cancer, diminishing the aftermath of treatment. The goal of this study is to measure differences in doses to the healthy tissue of the central nervous system with two radiotherapy techniques, both guided by computed tomography [es

  2. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-01-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  3. Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Hans [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Klinikum Brandenburg, Department of Cardiology, Angiology, and Pulmonology, Brandenburg an der Havel (Germany); Frieler, Katja [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Medical Statistics, Berlin (Germany); Potsdam Institut fuer Klimaforschung, Potsdam (Germany); Schlattmann, Peter [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Medical Statistics, Berlin (Germany); Hamm, Bernd [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Dewey, Marc [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology (Germany)

    2010-12-15

    Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiography in a retrospective longitudinal study. MDCT was performed by using a voxel size of 0.5 x 0.35 x 0.35 mm{sup 3} at two time points 25 {+-} 3 months apart. Non-calcified, calcified and mixed coronary plaque components were analysed by using volumetric measurement. The influence of statin, low-density lipoprotein (LDL) and risk factors was assessed by using a linear random intercept model for plaque growth. The volumes of non-calcified, calcified and mixed coronary plaques significantly (P < 0.001) increased from baseline (medians/interquartile ranges = 21/15-39, 7/3-20 and 36/16-69 mm{sup 3}) to follow-up (29/17-44, 13/6-29 and 41/20-75 mm{sup 3}). Statins significantly slowed the growth of non-calcified plaques (statin coefficient {beta} = -0.0036, P = 0.01) but did not significantly affect the growth rate of mixed or calcified plaques. The effect of statin treatment on non-calcified plaques remained significant after adjusting for LDL levels and cardiac risk factors. Quantification using MDCT shows that progression of non-calcified coronary plaques may be slowed by statins. (orig.)

  4. Pediatrics patient in computed tomography: risk awareness among medical staff

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Kosutic, D.; Lazarevic, Dj.

    2009-01-01

    In this paper the results of investigation about risk awareness in pediatrics computed tomography among medical staff are presented. Questionnaires were distributed along seven hospitals, 84 people were enrolled in this investigation. The results showed awareness of the potential risks associated with ionizing radiation in computed tomography. However, there is still widespread underestimation of relative doses and risks in case of pediatric patients. (author) [sr

  5. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  6. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  7. Computed tomography angiogram. Accuracy in renal surgery

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Al-Hathal, Naif; Al-Fuhaid, Turki; Raza, Sayed; Al-Yami, Fahad; Al-Taweel, Waleed; Alomar, Mohamed; Al-Nagshabandi, Nizar

    2009-01-01

    The objective of this study was to determine the sensitivity and specificity of computed tomography angiogram (CTA) in detecting number and location of renal arteries and veins as well as crossing vessels causing uretero-pelvic junction obstruction (UPJO), and to determine if this can be used in decision-making algorithms for treatment of UPJO. A prospective study was carried out in patients undergoing open, laparoscopic and robotic renal surgery from April 2005 until October 2006. All patients were imaged using CTA with 1.25 collimation of arterial and venous phases. Each multi-detector CTA was then read by one radiologist and his results were compared prospectively with the actual intra-operative findings. Overall, 118 patients were included. CTA had 93% sensitivity, 77% specificity and 90% overall accuracy for detecting a single renal artery, and 76% sensitivity, 92% specificity and 90% overall accuracy for detecting two or more renal arteries (Pearson χ 2 =0.001). There was 95% sensitivity, 84% specificity and 85% overall accuracy for detecting the number of renal veins. CTA had 100% overall accuracy in detecting early dividing renal artery (defined as less than 1.5 cm branching from origin), and 83.3% sensitivity, specificity and overall accuracy in detecting crossing vessels at UPJ. The percentage of surgeons stating CTA to be helpful as pre-operative diagnostic tool was 85%. Computed tomography angiogram is simple, quick and can provide an accurate pre-operative renal vascular anatomy in terms of number and location of renal vessels, early dividing renal arteries and crossing vessels at UPJ. (author)

  8. Quality Assurance Challenges for Motion-Adaptive Radiation Therapy: Gating, Breath Holding, and Four-Dimensional Computed Tomography

    International Nuclear Information System (INIS)

    Jiang, Steve B.; Wolfgang, John; Mageras, Gig S.

    2008-01-01

    Compared with conventional three-dimensional (3D) conformal radiation therapy and intensity-modulated radiation therapy treatments, quality assurance (QA) for motion-adaptive radiation therapy involves various challenges because of the added temporal dimension. Here we discuss those challenges for three specific techniques related to motion-adaptive therapy: namely respiratory gating, breath holding, and four-dimensional computed tomography. Similar to the introduction of any other new technologies in clinical practice, typical QA measures should be taken for these techniques also, including initial testing of equipment and clinical procedures, as well as frequent QA examinations during the early stage of implementation. Here, rather than covering every QA aspect in depth, we focus on some major QA challenges. The biggest QA challenge for gating and breath holding is how to ensure treatment accuracy when internal target position is predicted using external surrogates. Recommended QA measures for each component of treatment, including simulation, planning, patient positioning, and treatment delivery and verification, are discussed. For four-dimensional computed tomography, some major QA challenges have also been discussed

  9. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  10. Positron computed tomography: current state, clinical results and future trends

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  11. Classification of spondylolysis in the growing period based on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yoshimitsu; Kono, Sachu; Nagano, Junji; Sugawa, Isao (Seirei Hamamatsu Hospital, Shizuoka (Japan))

    1989-11-01

    Serial computed tomography (CT) images of 104 vertebrae were reviewed from 103 sport men aged 18 or under, in whom spondylolysis was radiologically suspected during the period from January 1985 through August 1988. Twenty-four vertebrae (23%) showed false positive CT for spondylolysis. Findings of CT in 80 vertebrae were classified into four types according to the degree of spondylolysis and bone sclerosis, and marginal morphology of the dissolved vertebra. X-ray images in the oblique projection revealed infraction in 53%, 74%, and 9% for Types I, II, and III, respectively; and pseudoarthrosis in 24% and 91% for Types II and II, respectively. In Type I, X-ray failed to reveal spondylolysis in 36%, although it was capable of denying it in 11%. Early spondylolysis, as observed in Type I, was difficult to diagnose on plain X-ray. In Type III, X-ray proved to be helpful in diagnosing spondylolysis. Diversified X-ray appearances of spondylolysis seemed to be attributable to the degree of spondylolysis and irregular running of the dissolved vertebra. An adhesion rate of 41% could be achieved with conservative therapy alone for Type I. These results indicated that CT may be helpful in the classification of spondylolysis that is required for conservative treatment aimed at bone adhesion. (N.K.).

  12. Classification of spondylolysis in the growing period based on computed tomography

    International Nuclear Information System (INIS)

    Kobayashi, Yoshimitsu; Kono, Sachu; Nagano, Junji; Sugawa, Isao

    1989-01-01

    Serial computed tomography (CT) images of 104 vertebrae were reviewed from 103 sport men aged 18 or under, in whom spondylolysis was radiologically suspected during the period from January 1985 through August 1988. Twenty-four vertebrae (23%) showed false positive CT for spondylolysis. Findings of CT in 80 vertebrae were classified into four types according to the degree of spondylolysis and bone sclerosis, and marginal morphology of the dissolved vertebra. X-ray images in the oblique projection revealed infraction in 53%, 74%, and 9% for Types I, II, and III, respectively; and pseudoarthrosis in 24% and 91% for Types II and II, respectively. In Type I, X-ray failed to reveal spondylolysis in 36%, although it was capable of denying it in 11%. Early spondylolysis, as observed in Type I, was difficult to diagnose on plain X-ray. In Type III, X-ray proved to be helpful in diagnosing spondylolysis. Diversified X-ray appearances of spondylolysis seemed to be attributable to the degree of spondylolysis and irregular running of the dissolved vertebra. An adhesion rate of 41% could be achieved with conservative therapy alone for Type I. These results indicated that CT may be helpful in the classification of spondylolysis that is required for conservative treatment aimed at bone adhesion. (N.K.)

  13. Comparison of helical computed tomography and ultrasonography in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Nafees, M.; Abbas, G.; Sarwar, S.

    2010-01-01

    The objective of study is to compare the diagnostic accuracy of helical computed tomography and ultrasonography in acute appendicitis using histopathology as gold standard. Thirty cases of clinically suspected acute appendicitis were included in the study selected on non probability convenience sampling technique. Computed tomography and graded compression ultrasonography of right lower quadrant of abdomen were conducted and results compared with histopathological findings. Amongst 30 patients who underwent computed tomography and graded compression ultrasonography examinations of right lower quadrant for diagnosis of acute appendicitis, on computed tomography 19 were diagnosed with acute appendicitis, 10 were diagnosed as not having the disease and 01 patient diagnosed as not having appendicitis on computed tomography did not improve clinically, was operated upon and histopathology proved it as acute appendicitis. While on graded compression ultrasonography 15 were diagnosed with acute appendicitis, 11 were diagnosed as not having the disease and 04 patients diagnosed as not having appendicitis on ultrasonography, did not improve clinically, were operated upon and histopathology proved it as acute appendicitis. This showed that CT scan has sensitivity of 95%, specificity 100%, positive predictive value 100%, negative predictive value 90.91% and overall accuracy of 96.67% while ultrasonography has sensitivity of 78.9%, specificity 100%, positive predictive value 100%, negative predictive value 73.33% and overall accuracy of 86.67%. We concluded that Helical computed tomography is highly accurate in diagnosing acute appendicitis as compared to ultrasonography and it helps to reduce negative appendectomy rate. (author)

  14. Computed tomography of the iliopsoas muscle

    International Nuclear Information System (INIS)

    Nino-Murcia, M.; Wechsler, R.J.; Brennan, R.E.

    1983-01-01

    Computed tomography (CT) is an ideal method for the imaging of the psoas muscle. The authors present 13 cases of patients with psoas abnormalities diagnosed by CT. The CT features of the different pathologic entities and comparison of CT with other imaging modalities are discussed. (orig.)

  15. Primary pulmonary lymphoma-role of fluoro-deoxy-glucose positron emission tomography-computed tomography in the initial staging and evaluating response to treatment - case reports and review of literature

    International Nuclear Information System (INIS)

    Agarwal, Krishan Kant; Dhanapathi, Halanaik; Nazar, Aftab Hasan; Kumar, Rakesh

    2016-01-01

    Primary pulmonary lymphoma (PPL) is an uncommon entity of non-Hodgkin lymphoma, which accounts for <1% of all cases of lymphoma. We present two rare cases of PPL of diffuse large B-cell lymphoma, which underwent 18 fluorine fluoro-deoxy-glucose positron emission tomography-computed tomography for initial staging and response evaluation after chemotherapy

  16. Computed tomography or necropsy diagnosis of multiple bullae and the treatment of pneumothorax in rhesus macaques (Macaca mulatta).

    Science.gov (United States)

    Kim, Jong-Min; Han, Sungyoung; Shin, Jun-Seop; Min, Byoung-Hoon; Jeong, Won Young; Lee, Ga Eul; Kim, Min Sun; Kim, Ju Eun; Chung, Hyunwoo; Park, Chung-Gyu

    2017-10-01

    Pulmonary bullae and pneumothorax have various etiologies in veterinary medicine. We diagnosed multiple pulmonary bullae combined with or without pneumothorax by computed tomography (CT) or necropsy in seven rhesus macaques (Macaca mulatta) imported from China. Two of seven rhesus macaques accompanied by pneumothorax were cured by fixation of ruptured lung through left or right 3rd intercostal thoracotomy. Pneumonyssus simicola, one of the etiologies of pulmonary bullae, was not detected from tracheobronchiolar lavage. To the best of our knowledge, this is the first case report on the CT-aided diagnosis of pulmonary bullae and the successful treatment of combined pneumothorax by thoracotomy in non-human primates (NHPs). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. [Cardiac computed tomography: new applications of an evolving technique].

    Science.gov (United States)

    Martín, María; Corros, Cecilia; Calvo, Juan; Mesa, Alicia; García-Campos, Ana; Rodríguez, María Luisa; Barreiro, Manuel; Rozado, José; Colunga, Santiago; de la Hera, Jesús M; Morís, César; Luyando, Luis H

    2015-01-01

    During the last years we have witnessed an increasing development of imaging techniques applied in Cardiology. Among them, cardiac computed tomography is an emerging and evolving technique. With the current possibility of very low radiation studies, the applications have expanded and go further coronariography In the present article we review the technical developments of cardiac computed tomography and its new applications. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  18. Cone Beam X-ray Luminescence Computed Tomography Based on Bayesian Method.

    Science.gov (United States)

    Zhang, Guanglei; Liu, Fei; Liu, Jie; Luo, Jianwen; Xie, Yaoqin; Bai, Jing; Xing, Lei

    2017-01-01

    X-ray luminescence computed tomography (XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. Combining the principles of X-ray excitation of luminescence-based probes and optical signal detection, XLCT naturally fuses functional and anatomical images and provides complementary information for a wide range of applications in biomedical research. In order to improve the data acquisition efficiency of previously developed narrow-beam XLCT, a cone beam XLCT (CB-XLCT) mode is adopted here to take advantage of the useful geometric features of cone beam excitation. Practically, a major hurdle in using cone beam X-ray for XLCT is that the inverse problem here is seriously ill-conditioned, hindering us to achieve good image quality. In this paper, we propose a novel Bayesian method to tackle the bottleneck in CB-XLCT reconstruction. The method utilizes a local regularization strategy based on Gaussian Markov random field to mitigate the ill-conditioness of CB-XLCT. An alternating optimization scheme is then used to automatically calculate all the unknown hyperparameters while an iterative coordinate descent algorithm is adopted to reconstruct the image with a voxel-based closed-form solution. Results of numerical simulations and mouse experiments show that the self-adaptive Bayesian method significantly improves the CB-XLCT image quality as compared with conventional methods.

  19. Primary Pulmonary Synovial Sarcoma: A Case with Unique and Impressive Computed Tomography Findings

    Directory of Open Access Journals (Sweden)

    Jaspreet S Kambo

    2015-01-01

    Full Text Available Primary pulmonary synovial sarcoma (PPSS is a rare malignancy. Its etiology, imaging features and optimal treatment are not well understood. Pulmonary pseudoaneurysms and lymphadenopathy are rare complications of synovial sarcomas. A 40-year-old woman with mild hemoptysis and thoracic back pain underwent a computed tomography scan that revealed multiple pulmonary lesions, paraesophageal lymphadenopathy and incidental bilateral pulmonary emboli. A diagnosis of PPSS was made through the identification of an SS18 translocation by fluorescence in situ hybridization. She was started on adriamycin, ifosfamide and mesna chemotherapy. Over the subsequent two months, she developed three pulmonary artery pseudoaneurysms, ultimately requiring endovascular coiling. Seven months after starting treatment, the patient was asymptomatic. The lesions and lymphadenopathy decreased in size. The present case highlights complications of a rare malignancy and demonstrates positive response to ifosfamide-based chemotherapy in the setting of PPSS.

  20. [Axial computer tomography of the neurocranium (author's transl)].

    Science.gov (United States)

    Stöppler, L

    1977-05-27

    Computer tomography (CT), a new radiographic examination technique, is very highly efficient, for it has high informative content with little stress for the patient. In contrast to the conventional X-ray technology, CT succeeds, by direct presentation of the structure of the soft parts, in obtaining information which comes close to that of macroscopic neuropathology. The capacity and limitations of the method at the present stage of development are reported. Computer tomography cannot displace conventional neuroradiological methods of investigation, although it is rightly presented as a screening method and helps towards selective use. Indications, technical integration and handling of CT are prerequisites for the exhaustive benefit of the excellent new technique.

  1. Internal structure of mandible around mandibular molar using computed tomography. Anatomical consideration of molar anchorage in orthodontic treatment

    International Nuclear Information System (INIS)

    Enomoto, Yutaka; Yamashita, Daisuke; Saito, Katsuhiko; Kasai, Kazutaka

    2008-01-01

    For establishment of fine occlusion, facial profile and oral function in orthodontic treatment, molar anchorage in teeth movement is important manner in extracted cases. The aims of this study were to investigate the relationship between facial morphology and internal structure of mandibular body in molar region by computer tomography, and to discuss about molar anchorage in orthodontic treatment. The data for this study were obtained from 35 modern male Japanese skulls (mean age; 27 year-old, ranged from 18 year-old to 47 year-old). Measurement variables were FMA, SN to mandibular plane angle, gonial angle, alveolar breadth, cortical bone thickness of buccal and lingual sides, and the distance between dental root and cortical bone. As a result, alveolar breadth and the distance between dental root and cortical bone were narrow in long facial type, on the contrary, these variables were wide in short facial type. The result suggested that these variables were considered important factors as molar anchorage in extracted cases. (author)

  2. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest...

  3. Cervical lymph node hyperplasia on [{sup 18}F]-fluorodeoxyglucose positron emission tomography/computed tomography scan after treatment of children and adolescents with malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Ying-Ying, E-mail: huyy@sysucc.org.cn; Zhang, Xu, E-mail: zhangxu2@sysucc.org.cn; Long, Wen, E-mail: longwen2@sysucc.org.cn; Lin, Xiao-Ping, E-mail: linxp@sysucc.org.cn; Zhang, Ya-Rui, E-mail: zhangyr@sysucc.org.cn; Li, Yuan-Hua, E-mail: liyh@sysucc.org.cn; Xiao, Zi-Zheng, E-mail: xiaozzh@sysucc.org.cn; Zheng, Rong-Liang, E-mail: zhengrl@sysucc.org.cn; Liang, Pei-Yan, E-mail: liangpy@sysucc.org.cn; Fan, Wei, E-mail: fanwei@sysucc.org.cn

    2015-07-15

    Highlights: • Cervical lymph node hyperplasia is a benign processes. • Lymph node hyperplasia found in treated children and adolescents with lymphoma. • We define imaging manifestations of cervical lymph node hyperplasia in PET/CT. • Awareness of lymph node hyperplasia avoid invasive procedures and over-treatment. - Abstract: Purpose: To define imaging manifestations and clinical prognosis of cervical lymph node hyperplasia using [{sup 18}F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning after treatment of children and adolescents with malignant lymphoma. Methods: Children and adolescent patients with malignant lymphoma who had high FDG uptake in their cervical lymph nodes via PET/CT after treatment, which was not due to tumor recurrence or residue, were retrospectively analyzed. Results: Twenty-seven patients with a median age of 12 years were included; 11 had Hodgkin's disease and 16 had non-Hodgkin's lymphoma. The time from PET/CT scan to completion of therapy was 1–36 months, 85.2% (23/27) of which took place within 12 months. Three patients had confirmed lymph node follicular hyperplasia by biopsy, while all 27 patients achieved disease-free survival during the follow-up period. The maximum standardized uptake values (SUV{sub max}) of cervical lymph nodes were 2.2–16.2 and the maximum short axis ranged from 0.3 to 1.2 cm. Cervical lymph node hyperplasia was noted in neck levels I–V, and neck level II bilaterally had the highest incidence (100%). Bilateral cervical lymph node hyperplasia was symmetrical in terms of both the SUV{sub max} and affected locations. Thymic hyperplasia and nasopharyngeal lymphoid hyperplasia were both observed in 24 patients (88.9%). There was no relationship in terms of the SUV{sub max} between cervical lymph nodes and thymic tissue, cervical nodes or nasopharyngeal lymphoid tissue. Conclusion: Cervical lymph node hyperplasia with high FDG uptake on PET/CT scans found

  4. Global Seismic Imaging Based on Adjoint Tomography

    Science.gov (United States)

    Bozdag, E.; Lefebvre, M.; Lei, W.; Peter, D. B.; Smith, J. A.; Zhu, H.; Komatitsch, D.; Tromp, J.

    2013-12-01

    Our aim is to perform adjoint tomography at the scale of globe to image the entire planet. We have started elastic inversions with a global data set of 253 CMT earthquakes with moment magnitudes in the range 5.8 ≤ Mw ≤ 7 and used GSN stations as well as some local networks such as USArray, European stations, etc. Using an iterative pre-conditioned conjugate gradient scheme, we initially set the aim to obtain a global crustal and mantle model with confined transverse isotropy in the upper mantle. Global adjoint tomography has so far remained a challenge mainly due to computational limitations. Recent improvements in our 3D solvers (e.g., a GPU version) and access to high-performance computational centers (e.g., ORNL's Cray XK7 "Titan" system) now enable us to perform iterations with higher-resolution (T > 9 s) and longer-duration (200 min) simulations to accommodate high-frequency body waves and major-arc surface waves, respectively, which help improve data coverage. The remaining challenge is the heavy I/O traffic caused by the numerous files generated during the forward/adjoint simulations and the pre- and post-processing stages of our workflow. We improve the global adjoint tomography workflow by adopting the ADIOS file format for our seismic data as well as models, kernels, etc., to improve efficiency on high-performance clusters. Our ultimate aim is to use data from all available networks and earthquakes within the magnitude range of our interest (5.5 ≤ Mw ≤ 7) which requires a solid framework to manage big data in our global adjoint tomography workflow. We discuss the current status and future of global adjoint tomography based on our initial results as well as practical issues such as handling big data in inversions and on high-performance computing systems.

  5. Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans

    NARCIS (Netherlands)

    Al-Rawi, B.; Hassan, B.; Vandenberge, B.; Jacobs, R.

    2010-01-01

    The use of three-dimensional (3D) models of the dentition obtained from cone beam computed tomography (CBCT) is becoming increasingly more popular in dentistry. A recent trend is to replace the traditional dental casts with digital CBCT models for diagnosis, treatment planning and simulation. The

  6. Magnetic resonance tomography and computed tomography of the brain for diagnosing Wilson's disease

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Straube, A.; Beyer, H.K.; Leopold, H.C.

    1985-01-01

    The authors report on two woman patients with confirmed Wilson's desease (hepatolenticular degeneration) who had neurological deficits and showed typical changes evident from laboratory data. Both computed tomography and magnetic resonance tomography revealed degenerative changes in the basal ganglia, especially of the lenticular nucleus, MR showing these defects more clearly than CT. There was a noticeable symmetrical enhancement of signals in the lenticular nucleus which was particularly evident on the image basing on the T 2 (spin-spin relaxation time constant) values. MR could be superior to CT with regard to showing up pathological changes in the basal ganglia. The future indication of MR could be the establishment of an exact correlation between clinical signs and symptoms on the one hand, and morphological findings on the other. Over and above this, it should be explored to what extent MR can already detect degenerative changes in the brain in primarily hepatic types of the disease even without prior neurological examination. (orig.) [de

  7. Molecular Imaging and Precision Medicine: PET/Computed Tomography and Therapy Response Assessment in Oncology.

    Science.gov (United States)

    Sheikhbahaei, Sara; Mena, Esther; Pattanayak, Puskar; Taghipour, Mehdi; Solnes, Lilja B; Subramaniam, Rathan M

    2017-01-01

    A variety of methods have been developed to assess tumor response to therapy. Standardized qualitative criteria based on 18F-fluoro-deoxyglucose PET/computed tomography have been proposed to evaluate the treatment effectiveness in specific cancers and these allow more accurate therapy response assessment and survival prognostication. Multiple studies have addressed the utility of the volumetric PET biomarkers as prognostic indicators but there is no consensus about the preferred segmentation methodology for these metrics. Heterogeneous intratumoral uptake was proposed as a novel PET metric for therapy response assessment. PET imaging techniques will be used to study the biological behavior of cancers during therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...

  9. Fourier-based approach to interpolation in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2001-01-01

    It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal direction and because the exploitation of the redundancy of fanbeam data acquired over 360 degree sign to generate additional longitudinal samples does not automatically eliminate the aliasing. In this paper we demonstrate that for pitches near 1 or lower, the redundant fanbeam data, when used properly, can provide sufficient information to satisfy a generalized sampling theorem and thus to eliminate aliasing. We develop and evaluate a Fourier-based algorithm, called 180FT, that accomplishes this. As background we present a second Fourier-based approach, called 360FT, that makes use only of the directly measured data. Both Fourier-based approaches exploit the fast Fourier transform and the Fourier shift theorem to generate from the helical projection data a set of fanbeam sinograms corresponding to equispaced transverse slices. Slice-by-slice reconstruction is then performed by use of two-dimensional fanbeam algorithms. The proposed approaches are compared to their counterparts based on the use of linear interpolation - the 360LI and 180LI approaches. The aliasing suppression property of the 180FT approach is a clear advantage of the approach and represents a step toward the desirable goal of achieving uniform longitudinal resolution properties in reconstructed helical CT volumes

  10. A true minimally invasive approach for cochlear implantation: high accuracy in cranial base navigation through flat-panel-based volume computed tomography.

    Science.gov (United States)

    Majdani, Omid; Bartling, Soenke H; Leinung, Martin; Stöver, Timo; Lenarz, Minoo; Dullin, Christian; Lenarz, Thomas

    2008-02-01

    High-precision intraoperative navigation using high-resolution flat-panel volume computed tomography makes feasible the possibility of minimally invasive cochlear implant surgery, including cochleostomy. Conventional cochlear implant surgery is typically performed via mastoidectomy with facial recess to identify and avoid damage to vital anatomic landmarks. To accomplish this procedure via a minimally invasive approach--without performing mastoidectomy--in a precise fashion, image-guided technology is necessary. With such an approach, surgical time and expertise may be reduced, and hearing preservation may be improved. Flat-panel volume computed tomography was used to scan 4 human temporal bones. A drilling channel was planned preoperatively from the mastoid surface to the round window niche, providing a margin of safety to all functional important structures (e.g., facial nerve, chorda tympani, incus). Postoperatively, computed tomographic imaging and conventional surgical exploration of the drilled route to the cochlea were performed. All 4 specimens showed a cochleostomy located at the scala tympani anterior inferior to the round window. The chorda tympani was damaged in 1 specimen--this was preoperatively planned as a narrow facial recess was encountered. Using flat-panel volume computed tomography for image-guided surgical navigation, we were able to perform minimally invasive cochlear implant surgery defined as a narrow, single-channel mastoidotomy with cochleostomy. Although this finding is preliminary, it is technologically achievable.

  11. Asymmetrically increased rib cage uptake on bone scintigraphy: Incidental detection of pleural mesothelioma on single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Dhull, Varun Singh; Sharma, Punit; Durgapal, Prashant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Follow-up bone scintigraphy (BS) in a patient of carcinoma left breast, who was treated with surgery followed by radiotherapy 12 years back, revealed asymmetrically increased radiotracer uptake in left-sided ribs. Since, this pattern was atypical for metastatic rib involvement, single photon emission computed tomography/computed tomography (SPECT/CT) of thorax was done in the same setting which revealed circumferential nodular left-sided pleural thickening. Biopsy confirmed it to be pleural mesothelioma. Left-sided ribs showed no abnormality on CT, thus suggesting the rib uptake as reactive in nature. This pattern of asymmetric rib uptake on BS should be kept in mind and warrants further investigation for determining underlying pathology

  12. Computed tomography as a source of electron density information for radiation treatment planning

    International Nuclear Information System (INIS)

    Skrzynski, Witold; Slusarczyk-Kacprzyk, Wioletta; Bulski, Wojciech; Zielinska-Dabrowska, Sylwia; Wachowicz, Marta; Kukolowicz, Pawel F.

    2010-01-01

    Purpose: to evaluate the performance of computed tomography (CT) systems of various designs as a source of electron density (ρ el ) data for treatment planning of radiation therapy. Material and methods: dependence of CT numbers on relative electron density of tissue-equivalent materials (HU-ρ el relationship) was measured for several general-purpose CT systems (single-slice, multislice, wide-bore multislice), for radiotherapy simulators with a single-slice CT and kV CBCT (cone-beam CT) options, as well as for linear accelerators with kV and MV CBCT systems. Electron density phantoms of four sizes were used. Measurement data were compared with the standard HU-ρ el relationships predefined in two commercial treatment-planning systems (TPS). Results: the HU-ρ el relationships obtained with all of the general-purpose CT scanners operating at voltages close to 120 kV were very similar to each other and close to those predefined in TPS. Some dependency of HU values on tube voltage was observed for bone-equivalent materials. For a given tube voltage, differences in results obtained for different phantoms were larger than those obtained for different CT scanners. For radiotherapy simulators and for kV CBCT systems, the information on ρ el was much less precise because of poor uniformity of images. For MV CBCT, the results were significantly different than for kV systems due to the differing energy spectrum of the beam. Conclusion: the HU-ρ el relationships predefined in TPS can be used for general-purpose CT systems operating at voltages close to 120 kV. For nontypical imaging systems (e.g., CBCT), the relationship can be significantly different and, therefore, it should always be measured and carefully analyzed before using CT data for treatment planning. (orig.)

  13. Computed tomography evaluation of autogenous graft in sinus lift surgery

    International Nuclear Information System (INIS)

    Ajzen, Sergio Aron; Moscatiello, Rafael Andrade; Lima, Aida Maria Custodio de; Moscatiello, Vitoria Aparecida Muglia; Helio Kiitiro Yamashita; Mosacatiello, Rafael Muglia; Nishiguchi, Celso Itiro; Alves, Maria Teresa de Seixas

    2001-01-01

    The objective was to quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from apheresis or centrifugation using computed tomography. This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months), with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by apheresis. The results showed that computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. It was concluded that clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants. (author)

  14. Detection of distant metastases in patients with locally advanced breast cancer: role of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography and conventional imaging with computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Andrade, Wesley Pereira; Cunha, Rodrigo Rodrigues da; Conrado, Jorge Luis Fonseca de Acioli; Lima, Eduardo Nobrega Pereira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens, E-mail: rodrigo.rcunha@hotmail.com [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Hospital Beneficincia Portuguesa de Sao Paulo, Sao Paulo, SP (Brazil)

    2017-07-15

    Objective: To evaluate positron emission tomography/computed tomography (PET/CT) and conventional imaging tests for the detection of distant metastases in patients with locally advanced breast cancer. Materials and Methods: We included 81 patients with breast cancer who had undergone {sup 18}-fluorodeoxyglucose (FDG) PET/CT before treatment. Conventional imaging included the following: bone scintigraphy; chest X-ray (in 14.5%) or CT (in 85.5%); and abdominal ultrasound (in 10.8%), CT (in 87.8%), or magnetic resonance imaging (in 1.4%). Histopathology and clinical/imaging follow-up served as reference. Results: Distant metastases were observed in nine patients (11.1%). On patient-based analysis, conventional imaging identified distant metastases in all 9 patients. In one patient, the initial {sup 18}F-FDG PET/CT failed to demonstrate bone metastases that was evident on bone scintigraphy. In two patients, the CT scan failed to show extra-axillary lymph node metastases that were identified on {sup 18}F-FDG PET/CT. There was no significant difference between {sup 18}F-FDG PET/CT and conventional imaging in terms of their sensitivity for the detection of distant metastases in patients with locally advanced breast cancer. Conclusion: This study showed that {sup 18}F-FDG PET/CT and conventional imaging with CT scans had similar sensitivity for the diagnosis of distant metastases in patients with locally advanced breast cancer. {sup 18}F-FDG PET/CT can add information about extra-axillary lymph node involvements. (author)

  15. The study of radiographic technique with low exposure using computed panoramic tomography

    International Nuclear Information System (INIS)

    Saito, Yasuhiro

    1987-01-01

    A new imaging system for the dental field that combines recent advances in both the electronics and computer technologies was developed. This new imaging system is a computed panoramic tomography process based on the newly developed laser-scan system. In this study a quantitative image evaluation was performed comparing anatomical landmark in computed panoramic tomography at a low exposure (LPT) and in conventional panoramic tomography at a routin (CPT), and the following results were obtained: 1. The diagnostic value of the CPT decreased with decreasing exposure, paticularly with regard to the normal anatomical landmarks of such microstructural parts as the periodontal space, lamina dura and the enamel-dentin border. 2. The LPT was highly diagnostic value for all normal anatomical landmark, averaging about twice as valuable diagnostically as CPT. 3. The visually diagnostic value of the periodontal space, lamina dura, enamel-dentin border and the anatomical morphology of the teeth on the LPT beeing slightly dependent on the spatial frequency enhancement rank. 4. The LPT formed images with almost the same range of density as the CPT. 5. Computed panoramic tomographs taken at a low exposure revealed more information of the trabecular bone pattern on the image than conventional panoramic tomographs taken under routine condition in the visual spatial frequency range (0.1 - 5.0 cycle/mm). (author) 67 refs

  16. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  17. Cone beam computed tomography: basics and applications in dentistry.

    Science.gov (United States)

    Venkatesh, Elluru; Elluru, Snehal Venkatesh

    2017-01-01

    The introduction of cone beam computed tomography (CBCT) devices, changed the way oral and maxillofacial radiology is practiced. CBCT was embraced into the dental settings very rapidly due to its compact size, low cost, low ionizing radiation exposure when compared to medical computed tomography. Alike medical CT, 3 dimensional evaluation of the maxillofacial region with minimal distortion is offered by the CBCT. This article provides an overview of basics of CBCT technology and reviews the specific application of CBCT technology to oral and maxillofacial region with few illustrations.

  18. Slice image pretreatment for cone-beam computed tomography based on adaptive filter

    International Nuclear Information System (INIS)

    Huang Kuidong; Zhang Dinghua; Jin Yanfang

    2009-01-01

    According to the noise properties and the serial slice image characteristics in Cone-Beam Computed Tomography (CBCT) system, a slice image pretreatment for CBCT based on adaptive filter was proposed. The judging criterion for the noise is established firstly. All pixels are classified into two classes: adaptive center weighted modified trimmed mean (ACWMTM) filter is used for the pixels corrupted by Gauss noise and adaptive median (AM) filter is used for the pixels corrupted by impulse noise. In ACWMTM filtering algorithm, the estimated Gauss noise standard deviation in the current slice image with offset window is replaced by the estimated standard deviation in the adjacent slice image to the current with the corresponding window, so the filtering accuracy of the serial images is improved. The pretreatment experiment on CBCT slice images of wax model of hollow turbine blade shows that the method makes a good performance both on eliminating noises and on protecting details. (authors)

  19. Computed tomography and plain radiography in experimental fracture healing

    International Nuclear Information System (INIS)

    Braunstein, E.M.; Goldstein, S.A.; Ku, J.; Smith, P.; Matthews, L.S.

    1986-01-01

    We evaluated the relative contribution of plain radiographs and computed tomography to the assessment of fracture healing under experimental circumstances. In 15 sheep, we performed midshaft femoral osteotomies and internal fixation of the resultant segmental fractures. Radiographs were obtained preoperatively and immediately postoperatively. Animals were sacrificed at 3 weeks, 6 weeks, 12 weeks, 24 weeks, and 36 weeks after surgery, and the femoral specimens radiographed. After removal of the internal fixation devices, computed tomographic scans of the specimens were performed. Computed tomography may be of value in the evaluation of fractures of long bones in those cases in which clinical examination and plain radiographs fail to give adequate information as to the status of healing. (orig./SHA)

  20. Development of industrial x-ray computed tomography and its application to refractories

    International Nuclear Information System (INIS)

    Aiba, Yoshiro; Oki, Kazuo; Nakamura, Shigeo; Fujii, Masashi.

    1985-01-01

    An industrial X-ray computed tomography was developed under the influence of the rapid spread of the use of the X-ray CT scanner in the medical field and improvements of the equipment. Although current nondestructive testing machines of refractories use the ultrasonic inspection method or the X-ray fluoroscopic method, these equipments cannot produce a tomogram or cannot carry out quantitative evaluation. By using an industrial X-ray computed tomography, submerged nozzles for continuous casting of steel were analyzed with interesting results. The features of the industrial X-ray computed tomography applied for refractory nozzles are as follows: (1) It promptly detects interior defects. (2) It can measure dimensions and shapes. (3) It can numerically express the distribution of density. Accordingly, it is expected that the industrial X-ray computed tomography will widely be used in the fields of development and quality control of refractories and advanced ceramic materials. (author)