WorldWideScience

Sample records for computed tomography model-based

  1. Model-based image reconstruction in X-ray computed tomography

    NARCIS (Netherlands)

    Zbijewski, Wojciech Bartosz

    2006-01-01

    The thesis investigates the applications of iterative, statistical reconstruction (SR) algorithms in X-ray Computed Tomography. Emphasis is put on various aspects of system modeling in statistical reconstruction. Fundamental issues such as effects of object discretization and algorithm

  2. Generation of three-dimensional prototype models based on cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, J.T.; Berndt, D.C.; Zehnder, M. [University of Basel, Department of Oral Surgery, University Hospital for Oral Surgery, Oral Radiology and Oral Medicine, Basel (Switzerland); Schumacher, R. [University of Applied Sciences Northwestern Switzerland, School of Life Sciences, Institute for Medical and Analytical Technologies, Muttenz (Switzerland)

    2009-03-15

    The purpose of this study was to generate three-dimensional models based on digital volumetric data that can be used in basic and advanced education. Four sets of digital volumetric data were established by cone beam computed tomography (CBCT) (Accuitomo, J. Morita, Kyoto, Japan). Datasets were exported as Dicom formats and imported into Mimics and Magic software programs to separate the different tissues such as nerve, tooth and bone. These data were transferred to a Polyjet 3D Printing machine (Eden 330, Object, Israel) to generate the models. Three-dimensional prototype models of certain limited anatomical structures as acquired volumetrically were fabricated. Generating three-dimensional models based on CBCT datasets is possible. Automated routine fabrication of these models, with the given infrastructure, is too time-consuming and therefore too expensive. (orig.)

  3. Generation of three-dimensional prototype models based on cone beam computed tomography

    International Nuclear Information System (INIS)

    Lambrecht, J.T.; Berndt, D.C.; Zehnder, M.; Schumacher, R.

    2009-01-01

    The purpose of this study was to generate three-dimensional models based on digital volumetric data that can be used in basic and advanced education. Four sets of digital volumetric data were established by cone beam computed tomography (CBCT) (Accuitomo, J. Morita, Kyoto, Japan). Datasets were exported as Dicom formats and imported into Mimics and Magic software programs to separate the different tissues such as nerve, tooth and bone. These data were transferred to a Polyjet 3D Printing machine (Eden 330, Object, Israel) to generate the models. Three-dimensional prototype models of certain limited anatomical structures as acquired volumetrically were fabricated. Generating three-dimensional models based on CBCT datasets is possible. Automated routine fabrication of these models, with the given infrastructure, is too time-consuming and therefore too expensive. (orig.)

  4. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  5. Simulation-Based Planning of Optimal Conditions for Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Reisinger, S.; Kasperl, S.; Franz, M.

    2011-01-01

    We present a method to optimise conditions for industrial computed tomography (CT). This optimisation is based on a deterministic simulation. Our algorithm finds task-specific CT equipment settings to achieve optimal exposure parameters by means of an STL-model of the specimen and a raytracing...

  6. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D. [UCSF Benioff Children' s Hospital, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2014-07-15

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model-based

  7. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    International Nuclear Information System (INIS)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D.

    2014-01-01

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model-based

  8. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Kitslaar, Pieter H.; Broersen, Alexander

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model- based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) im- ages on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods...

  9. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  10. Radiomics-based differentiation of lung disease models generated by polluted air based on X-ray computed tomography data.

    Science.gov (United States)

    Szigeti, Krisztián; Szabó, Tibor; Korom, Csaba; Czibak, Ilona; Horváth, Ildikó; Veres, Dániel S; Gyöngyi, Zoltán; Karlinger, Kinga; Bergmann, Ralf; Pócsik, Márta; Budán, Ferenc; Máthé, Domokos

    2016-02-11

    Lung diseases (resulting from air pollution) require a widely accessible method for risk estimation and early diagnosis to ensure proper and responsive treatment. Radiomics-based fractal dimension analysis of X-ray computed tomography attenuation patterns in chest voxels of mice exposed to different air polluting agents was performed to model early stages of disease and establish differential diagnosis. To model different types of air pollution, BALBc/ByJ mouse groups were exposed to cigarette smoke combined with ozone, sulphur dioxide gas and a control group was established. Two weeks after exposure, the frequency distributions of image voxel attenuation data were evaluated. Specific cut-off ranges were defined to group voxels by attenuation. Cut-off ranges were binarized and their spatial pattern was associated with calculated fractal dimension, then abstracted by the fractal dimension -- cut-off range mathematical function. Nonparametric Kruskal-Wallis (KW) and Mann-Whitney post hoc (MWph) tests were used. Each cut-off range versus fractal dimension function plot was found to contain two distinctive Gaussian curves. The ratios of the Gaussian curve parameters are considerably significant and are statistically distinguishable within the three exposure groups. A new radiomics evaluation method was established based on analysis of the fractal dimension of chest X-ray computed tomography data segments. The specific attenuation patterns calculated utilizing our method may diagnose and monitor certain lung diseases, such as chronic obstructive pulmonary disease (COPD), asthma, tuberculosis or lung carcinomas.

  11. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  12. Physics Model-Based Scatter Correction in Multi-Source Interior Computed Tomography.

    Science.gov (United States)

    Gong, Hao; Li, Bin; Jia, Xun; Cao, Guohua

    2018-02-01

    Multi-source interior computed tomography (CT) has a great potential to provide ultra-fast and organ-oriented imaging at low radiation dose. However, X-ray cross scattering from multiple simultaneously activated X-ray imaging chains compromises imaging quality. Previously, we published two hardware-based scatter correction methods for multi-source interior CT. Here, we propose a software-based scatter correction method, with the benefit of no need for hardware modifications. The new method is based on a physics model and an iterative framework. The physics model was derived analytically, and was used to calculate X-ray scattering signals in both forward direction and cross directions in multi-source interior CT. The physics model was integrated to an iterative scatter correction framework to reduce scatter artifacts. The method was applied to phantom data from both Monte Carlo simulations and physical experimentation that were designed to emulate the image acquisition in a multi-source interior CT architecture recently proposed by our team. The proposed scatter correction method reduced scatter artifacts significantly, even with only one iteration. Within a few iterations, the reconstructed images fast converged toward the "scatter-free" reference images. After applying the scatter correction method, the maximum CT number error at the region-of-interests (ROIs) was reduced to 46 HU in numerical phantom dataset and 48 HU in physical phantom dataset respectively, and the contrast-noise-ratio at those ROIs increased by up to 44.3% and up to 19.7%, respectively. The proposed physics model-based iterative scatter correction method could be useful for scatter correction in dual-source or multi-source CT.

  13. Radiomics-based differentiation of lung disease models generated by polluted air based on X-ray computed tomography data

    International Nuclear Information System (INIS)

    Szigeti, Krisztián; Szabó, Tibor; Korom, Csaba; Czibak, Ilona; Horváth, Ildikó; Veres, Dániel S.; Gyöngyi, Zoltán; Karlinger, Kinga; Bergmann, Ralf; Pócsik, Márta; Budán, Ferenc; Máthé, Domokos

    2016-01-01

    Lung diseases (resulting from air pollution) require a widely accessible method for risk estimation and early diagnosis to ensure proper and responsive treatment. Radiomics-based fractal dimension analysis of X-ray computed tomography attenuation patterns in chest voxels of mice exposed to different air polluting agents was performed to model early stages of disease and establish differential diagnosis. To model different types of air pollution, BALBc/ByJ mouse groups were exposed to cigarette smoke combined with ozone, sulphur dioxide gas and a control group was established. Two weeks after exposure, the frequency distributions of image voxel attenuation data were evaluated. Specific cut-off ranges were defined to group voxels by attenuation. Cut-off ranges were binarized and their spatial pattern was associated with calculated fractal dimension, then abstracted by the fractal dimension -- cut-off range mathematical function. Nonparametric Kruskal-Wallis (KW) and Mann–Whitney post hoc (MWph) tests were used. Each cut-off range versus fractal dimension function plot was found to contain two distinctive Gaussian curves. The ratios of the Gaussian curve parameters are considerably significant and are statistically distinguishable within the three exposure groups. A new radiomics evaluation method was established based on analysis of the fractal dimension of chest X-ray computed tomography data segments. The specific attenuation patterns calculated utilizing our method may diagnose and monitor certain lung diseases, such as chronic obstructive pulmonary disease (COPD), asthma, tuberculosis or lung carcinomas. The online version of this article (doi:10.1186/s12880-016-0118-z) contains supplementary material, which is available to authorized users

  14. Computed tomography vs. digital radiography assessment for detection of osteolysis in asymptomatic patients with uncemented cups: a proposal for a new classification system based on computer tomography.

    Science.gov (United States)

    Sandgren, Buster; Crafoord, Joakim; Garellick, Göran; Carlsson, Lars; Weidenhielm, Lars; Olivecrona, Henrik

    2013-10-01

    Digital radiographic images in the anterior-posterior and lateral view have been gold standard for evaluation of peri-acetabular osteolysis for patients with an uncemented hip replacement. We compared digital radiographic images and computer tomography in detection of peri-acetabular osteolysis and devised a classification system based on computer tomography. Digital radiographs were compared with computer tomography on 206 hips, with a mean follow up 10 years after surgery. The patients had no clinical signs of osteolysis and none were planned for revision surgery. On digital radiographs, 192 cases had no osteolysis and only 14 cases had osteolysis. When using computer tomography there were 184 cases showing small or large osteolysis and only 22 patients had no osteolysis. A classification system for peri-acetabular osteolysis is proposed based on computer tomography that is easy to use on standard follow up evaluation. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Radiative transport-based frequency-domain fluorescence tomography

    International Nuclear Information System (INIS)

    Joshi, Amit; Rasmussen, John C; Sevick-Muraca, Eva M; Wareing, Todd A; McGhee, John

    2008-01-01

    We report the development of radiative transport model-based fluorescence optical tomography from frequency-domain boundary measurements. The coupled radiative transport model for describing NIR fluorescence propagation in tissue is solved by a novel software based on the established Attila(TM) particle transport simulation platform. The proposed scheme enables the prediction of fluorescence measurements with non-contact sources and detectors at a minimal computational cost. An adjoint transport solution-based fluorescence tomography algorithm is implemented on dual grids to efficiently assemble the measurement sensitivity Jacobian matrix. Finally, we demonstrate fluorescence tomography on a realistic computational mouse model to locate nM to μM fluorophore concentration distributions in simulated mouse organs

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  17. Quantification of root water uptake in soil using X-ray computed tomography and image-based modelling.

    Science.gov (United States)

    Daly, Keith R; Tracy, Saoirse R; Crout, Neil M J; Mairhofer, Stefan; Pridmore, Tony P; Mooney, Sacha J; Roose, Tiina

    2018-01-01

    Spatially averaged models of root-soil interactions are often used to calculate plant water uptake. Using a combination of X-ray computed tomography (CT) and image-based modelling, we tested the accuracy of this spatial averaging by directly calculating plant water uptake for young wheat plants in two soil types. The root system was imaged using X-ray CT at 2, 4, 6, 8 and 12 d after transplanting. The roots were segmented using semi-automated root tracking for speed and reproducibility. The segmented geometries were converted to a mesh suitable for the numerical solution of Richards' equation. Richards' equation was parameterized using existing pore scale studies of soil hydraulic properties in the rhizosphere of wheat plants. Image-based modelling allows the spatial distribution of water around the root to be visualized and the fluxes into the root to be calculated. By comparing the results obtained through image-based modelling to spatially averaged models, the impact of root architecture and geometry in water uptake was quantified. We observed that the spatially averaged models performed well in comparison to the image-based models with <2% difference in uptake. However, the spatial averaging loses important information regarding the spatial distribution of water near the root system. © 2017 John Wiley & Sons Ltd.

  18. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  19. Bayesian Multi-Energy Computed Tomography reconstruction approaches based on decomposition models

    International Nuclear Information System (INIS)

    Cai, Caifang

    2013-01-01

    Multi-Energy Computed Tomography (MECT) makes it possible to get multiple fractions of basis materials without segmentation. In medical application, one is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical MECT measurements are usually obtained with polychromatic X-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam poly-chromaticity fail to estimate the correct decomposition fractions and result in Beam-Hardening Artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log pre-processing and the water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on non-linear forward models counting the beam poly-chromaticity show great potential for giving accurate fraction images.This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint Maximum A Posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a non-quadratic cost function. To solve it, the use of a monotone Conjugate Gradient (CG) algorithm with suboptimal descent steps is proposed.The performances of the proposed approach are analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also

  20. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  2. Using high resolution X-ray computed tomography to create an image based model of a lymph node.

    Science.gov (United States)

    Cooper, L J; Zeller-Plumhoff, B; Clough, G F; Ganapathisubramani, B; Roose, T

    2018-07-14

    Lymph nodes are an important part of the immune system. They filter the lymphatic fluid as it is transported from the tissues before being returned to the blood stream. The fluid flow through the nodes influences the behaviour of the immune cells that gather within the nodes and the structure of the node itself. Measuring the fluid flow in lymph nodes experimentally is challenging due to their small size and fragility. In this paper, we present high resolution X-ray computed tomography images of a murine lymph node. The impact of the resulting visualized structures on fluid transport are investigated using an image based model. The high contrast between different structures within the lymph node provided by phase contrast X-ray computed tomography reconstruction results in images that, when related to the permeability of the lymph node tissue, suggest an increased fluid velocity through the interstitial channels in the lymph node tissue. Fluid taking a direct path from the afferent to the efferent lymphatic vessel, through the centre of the node, moved faster than the fluid that flowed around the periphery of the lymph node. This is a possible mechanism for particles being moved into the cortex. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  5. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  6. Registration-based Reconstruction of Four-dimensional Cone Beam Computed Tomography

    DEFF Research Database (Denmark)

    Christoffersen, Christian; Hansen, David Christoffer; Poulsen, Per Rugaard

    2013-01-01

    We present a new method for reconstruction of four-dimensional (4D) cone beam computed tomography from an undersampled set of X-ray projections. The novelty of the proposed method lies in utilizing optical flow based registration to facilitate that each temporal phase is reconstructed from the full...

  7. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  8. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  9. Design and analysis of a tendon-based computed tomography-compatible robot with remote center of motion for lung biopsy.

    Science.gov (United States)

    Yang, Yunpeng; Jiang, Shan; Yang, Zhiyong; Yuan, Wei; Dou, Huaisu; Wang, Wei; Zhang, Daguang; Bian, Yuan

    2017-04-01

    Nowadays, biopsy is a decisive method of lung cancer diagnosis, whereas lung biopsy is time-consuming, complex and inaccurate. So a computed tomography-compatible robot for rapid and precise lung biopsy is developed in this article. According to the actual operation process, the robot is divided into two modules: 4-degree-of-freedom position module for location of puncture point is appropriate for patient's almost all positions and 3-degree-of-freedom tendon-based orientation module with remote center of motion is compact and computed tomography-compatible to orientate and insert needle automatically inside computed tomography bore. The workspace of the robot surrounds patient's thorax, and the needle tip forms a cone under patient's skin. A new error model of the robot based on screw theory is proposed in view of structure error and actuation error, which are regarded as screw motions. Simulation is carried out to verify the precision of the error model contrasted with compensation via inverse kinematics. The results of insertion experiment on specific phantom prove the feasibility of the robot with mean error of 1.373 mm in laboratory environment, which is accurate enough to replace manual operation.

  10. A simple parametric model observer for quality assurance in computer tomography

    Science.gov (United States)

    Anton, M.; Khanin, A.; Kretz, T.; Reginatto, M.; Elster, C.

    2018-04-01

    Model observers are mathematical classifiers that are used for the quality assessment of imaging systems such as computer tomography. The quality of the imaging system is quantified by means of the performance of a selected model observer. For binary classification tasks, the performance of the model observer is defined by the area under its ROC curve (AUC). Typically, the AUC is estimated by applying the model observer to a large set of training and test data. However, the recording of these large data sets is not always practical for routine quality assurance. In this paper we propose as an alternative a parametric model observer that is based on a simple phantom, and we provide a Bayesian estimation of its AUC. It is shown that a limited number of repeatedly recorded images (10–15) is already sufficient to obtain results suitable for the quality assessment of an imaging system. A MATLAB® function is provided for the calculation of the results. The performance of the proposed model observer is compared to that of the established channelized Hotelling observer and the nonprewhitening matched filter for simulated images as well as for images obtained from a low-contrast phantom on an x-ray tomography scanner. The results suggest that the proposed parametric model observer, along with its Bayesian treatment, can provide an efficient, practical alternative for the quality assessment of CT imaging systems.

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  13. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  16. A proposal for standardizing computed tomography reports on abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Torlai, Fabiola Goda; Meirelles, Gustavo S. Portes; Miranda Junior, Fausto; Fonseca, Jose Honorio A.P. da; Ajzen, Sergio; D'Ippolito, Giuseppe

    2006-01-01

    Objective: to propose a model to standardize computed tomography reports on abdominal aortic aneurysms. Materials and methods: interviews were carried out with members of the Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5% (5/9). Results: the most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms were: maximum diameter of proximal aortic neck, proximal aortic neck length to lower renal arteries, shape of proximal aortic neck, maximum diameter of the aneurysm and diameter of the common iliac arteries. These data allowed the development of a proposal for a model to standardize computed tomography reports. Conclusion: a model for standardized tomographic analysis of abdominal aortic aneurysms has met vascular surgeons' needs for following-up patients and planning their treatment. (author)

  17. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  18. An energy-based beam hardening model in tomography

    International Nuclear Information System (INIS)

    Casteele, E van de; Dyck, D van; Sijbers, J; Raman, E

    2002-01-01

    As a consequence of the polychromatic x-ray source, used in micro-computer tomography (μCT) and in medical CT, the attenuation is no longer a linear function of absorber thickness. If this nonlinear beam hardening effect is not compensated, the reconstructed images will be corrupted by cupping artefacts. In this paper, a bimodal energy model for the detected energy spectrum is presented, which can be used for reduction of artefacts caused by beam hardening in well-specified conditions. Based on the combination of the spectrum of the source and the detector efficiency, the assumption is made that there are two dominant energies which can describe the system. The validity of the proposed model is examined by fitting the model to the experimental datapoints obtained on a microtomograph for different materials and source voltages

  19. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches

    NARCIS (Netherlands)

    Nada, R.M.; Maal, T.J.J.; Breuning, K.H.; Berge, S.J.; Mostafa, Y.A.; Kuijpers-Jagtman, A.M.

    2011-01-01

    Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans.

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  1. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  2. Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

    Science.gov (United States)

    Karki, Kishor; Saraiya, Siddharth; Hugo, Geoffrey D; Mukhopadhyay, Nitai; Jan, Nuzhat; Schuster, Jessica; Schutzer, Matthew; Fahrner, Lester; Groves, Robert; Olsen, Kathryn M; Ford, John C; Weiss, Elisabeth

    2017-09-01

    To investigate interobserver delineation variability for gross tumor volumes of primary lung tumors and associated pathologic lymph nodes using magnetic resonance imaging (MRI), and to compare the results with computed tomography (CT) alone- and positron emission tomography (PET)-CT-based delineations. Seven physicians delineated the tumor volumes of 10 patients for the following scenarios: (1) CT only, (2) PET-CT fusion images registered to CT ("clinical standard"), and (3) postcontrast T1-weighted MRI registered with diffusion-weighted MRI. To compute interobserver variability, the median surface was generated from all observers' contours and used as the reference surface. A physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest wall) on the median surface. Contoured volumes and bidirectional local distances between individual observers' contours and the reference contour were analyzed. Computed tomography- and MRI-based tumor volumes normalized relative to PET-CT-based volumes were 1.62 ± 0.76 (mean ± standard deviation) and 1.38 ± 0.44, respectively. Volume differences between the imaging modalities were not significant. Between observers, the mean normalized volumes per patient averaged over all patients varied significantly by a factor of 1.6 (MRI) and 2.0 (CT and PET-CT) (P=4.10 × 10 -5 to 3.82 × 10 -9 ). The tumor-atelectasis interface had a significantly higher variability than other interfaces for all modalities combined (P=.0006). The interfaces with the smallest uncertainties were tumor-lung (on CT) and tumor-mediastinum (on PET-CT and MRI). Although MRI-based contouring showed overall larger variability than PET-CT, contouring variability depended on the interface type and was not significantly different between modalities, despite the limited observer experience with MRI. Multimodality imaging and combining different imaging characteristics might be the best approach to define

  3. [Contribution of X-ray computed tomography in the evaluation of kidney performance].

    Science.gov (United States)

    Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent

    2012-07-01

    X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. Copyright © 2011 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  4. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  5. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  6. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  7. Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    Science.gov (United States)

    Wagner, Maximilian E H; Gellrich, Nils-Claudius; Friese, Karl-Ingo; Becker, Matthias; Wolter, Franz-Erich; Lichtenstein, Juergen T; Stoetzer, Marcus; Rana, Majeed; Essig, Harald

    2016-01-01

    Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior tissue representation, although CBCT has the benefit of greater availability and lower patient radiation exposure. Therefore, a model-based segmentation technique is presented as a new method for measuring orbital volume and compared to alternative techniques. Both eyes from thirty subjects with no known orbital pathology who had undergone CBCT as a part of routine care were evaluated (n = 60 eyes). Orbital volume was measured with manual, atlas-based, and model-based segmentation methods. Volume measurements, volume determination time, and usability were compared between the three methods. Differences in means were tested for statistical significance using two-tailed Student's t tests. Neither atlas-based (26.63 ± 3.15 mm(3)) nor model-based (26.87 ± 2.99 mm(3)) measurements were significantly different from manual volume measurements (26.65 ± 4.0 mm(3)). However, the time required to determine orbital volume was significantly longer for manual measurements (10.24 ± 1.21 min) than for atlas-based (6.96 ± 2.62 min, p < 0.001) or model-based (5.73 ± 1.12 min, p < 0.001) measurements. All three orbital volume measurement methods examined can accurately measure orbital volume, although atlas-based and model-based methods seem to be more user-friendly and less time-consuming. The new model-based technique achieves fully automated segmentation results, whereas all atlas-based segmentations at least required manipulations to the anterior closing. Additionally, model-based segmentation can provide reliable orbital volume measurements when CT image quality is poor.

  8. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  9. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  10. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  11. Simulation-based artifact correction (SBAC) for metrological computed tomography

    Science.gov (United States)

    Maier, Joscha; Leinweber, Carsten; Sawall, Stefan; Stoschus, Henning; Ballach, Frederic; Müller, Tobias; Hammer, Michael; Christoph, Ralf; Kachelrieß, Marc

    2017-06-01

    Computed tomography (CT) is a valuable tool for the metrolocical assessment of industrial components. However, the application of CT to the investigation of highly attenuating objects or multi-material components is often restricted by the presence of CT artifacts caused by beam hardening, x-ray scatter, off-focal radiation, partial volume effects or the cone-beam reconstruction itself. In order to overcome this limitation, this paper proposes an approach to calculate a correction term that compensates for the contribution of artifacts and thus enables an appropriate assessment of these components using CT. Therefore, we make use of computer simulations of the CT measurement process. Based on an appropriate model of the object, e.g. an initial reconstruction or a CAD model, two simulations are carried out. One simulation considers all physical effects that cause artifacts using dedicated analytic methods as well as Monte Carlo-based models. The other one represents an ideal CT measurement i.e. a measurement in parallel beam geometry with a monochromatic, point-like x-ray source and no x-ray scattering. Thus, the difference between these simulations is an estimate for the present artifacts and can be used to correct the acquired projection data or the corresponding CT reconstruction, respectively. The performance of the proposed approach is evaluated using simulated as well as measured data of single and multi-material components. Our approach yields CT reconstructions that are nearly free of artifacts and thereby clearly outperforms commonly used artifact reduction algorithms in terms of image quality. A comparison against tactile reference measurements demonstrates the ability of the proposed approach to increase the accuracy of the metrological assessment significantly.

  12. Total variation-based neutron computed tomography

    Science.gov (United States)

    Barnard, Richard C.; Bilheux, Hassina; Toops, Todd; Nafziger, Eric; Finney, Charles; Splitter, Derek; Archibald, Rick

    2018-05-01

    We perform the neutron computed tomography reconstruction problem via an inverse problem formulation with a total variation penalty. In the case of highly under-resolved angular measurements, the total variation penalty suppresses high-frequency artifacts which appear in filtered back projections. In order to efficiently compute solutions for this problem, we implement a variation of the split Bregman algorithm; due to the error-forgetting nature of the algorithm, the computational cost of updating can be significantly reduced via very inexact approximate linear solvers. We present the effectiveness of the algorithm in the significantly low-angular sampling case using synthetic test problems as well as data obtained from a high flux neutron source. The algorithm removes artifacts and can even roughly capture small features when an extremely low number of angles are used.

  13. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  14. GPU-based cone beam computed tomography.

    Science.gov (United States)

    Noël, Peter B; Walczak, Alan M; Xu, Jinhui; Corso, Jason J; Hoffmann, Kenneth R; Schafer, Sebastian

    2010-06-01

    The use of cone beam computed tomography (CBCT) is growing in the clinical arena due to its ability to provide 3D information during interventions, its high diagnostic quality (sub-millimeter resolution), and its short scanning times (60 s). In many situations, the short scanning time of CBCT is followed by a time-consuming 3D reconstruction. The standard reconstruction algorithm for CBCT data is the filtered backprojection, which for a volume of size 256(3) takes up to 25 min on a standard system. Recent developments in the area of Graphic Processing Units (GPUs) make it possible to have access to high-performance computing solutions at a low cost, allowing their use in many scientific problems. We have implemented an algorithm for 3D reconstruction of CBCT data using the Compute Unified Device Architecture (CUDA) provided by NVIDIA (NVIDIA Corporation, Santa Clara, California), which was executed on a NVIDIA GeForce GTX 280. Our implementation results in improved reconstruction times from minutes, and perhaps hours, to a matter of seconds, while also giving the clinician the ability to view 3D volumetric data at higher resolutions. We evaluated our implementation on ten clinical data sets and one phantom data set to observe if differences occur between CPU and GPU-based reconstructions. By using our approach, the computation time for 256(3) is reduced from 25 min on the CPU to 3.2 s on the GPU. The GPU reconstruction time for 512(3) volumes is 8.5 s. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  15. Polarimetry data inversion in conditions of tokamak plasma: Model based tomography concept

    International Nuclear Information System (INIS)

    Bieg, B.; Chrzanowski, J.; Kravtsov, Yu. A.; Mazon, D.

    2015-01-01

    Highlights: • Model based plasma tomography is presented. • Minimization procedure for the error function is suggested to be performed using the gradient method. • model based procedure of data inversion in the case of joint polarimetry–interferometry data. - Abstract: Model based plasma tomography is studied which fits a hypothetical multi-parameter plasma model to polarimetry and interferometry experimental data. Fitting procedure implies minimization of the error function, defined as a sum of squared differences between theoretical and empirical values. Minimization procedure for the function is suggested to be performed using the gradient method. Contrary to traditional tomography, which deals exclusively with observational data, model-based tomography (MBT) operates also with reasonable model of inhomogeneous plasma distribution and verifies which profile of a given class better fits experimental data. Model based tomography (MBT) restricts itself by definite class of models for instance power series, Fourier expansion etc. The basic equations of MBT are presented which generalize the equations of model based procedure of polarimetric data inversion in the case of joint polarimetry–interferometry data.

  16. Polarimetry data inversion in conditions of tokamak plasma: Model based tomography concept

    Energy Technology Data Exchange (ETDEWEB)

    Bieg, B. [Maritime University of Szczecin, Waly Chrobrego 1-2, 70-500 Szczecin (Poland); Chrzanowski, J., E-mail: j.chrzanowski@am.szczecin.pl [Maritime University of Szczecin, Waly Chrobrego 1-2, 70-500 Szczecin (Poland); Kravtsov, Yu. A. [Maritime University of Szczecin, Waly Chrobrego 1-2, 70-500 Szczecin (Poland); Space Research Institute, Profsoyuznaya St. 82/34 Russian Academy of Science, Moscow 117997 (Russian Federation); Mazon, D. [CEA, IRFM, F-13108 Saint Paul-lez-Durance (France)

    2015-10-15

    Highlights: • Model based plasma tomography is presented. • Minimization procedure for the error function is suggested to be performed using the gradient method. • model based procedure of data inversion in the case of joint polarimetry–interferometry data. - Abstract: Model based plasma tomography is studied which fits a hypothetical multi-parameter plasma model to polarimetry and interferometry experimental data. Fitting procedure implies minimization of the error function, defined as a sum of squared differences between theoretical and empirical values. Minimization procedure for the function is suggested to be performed using the gradient method. Contrary to traditional tomography, which deals exclusively with observational data, model-based tomography (MBT) operates also with reasonable model of inhomogeneous plasma distribution and verifies which profile of a given class better fits experimental data. Model based tomography (MBT) restricts itself by definite class of models for instance power series, Fourier expansion etc. The basic equations of MBT are presented which generalize the equations of model based procedure of polarimetric data inversion in the case of joint polarimetry–interferometry data.

  17. Computer-based quantitative computed tomography image analysis in idiopathic pulmonary fibrosis: A mini review.

    Science.gov (United States)

    Ohkubo, Hirotsugu; Nakagawa, Hiroaki; Niimi, Akio

    2018-01-01

    Idiopathic pulmonary fibrosis (IPF) is the most common type of progressive idiopathic interstitial pneumonia in adults. Many computer-based image analysis methods of chest computed tomography (CT) used in patients with IPF include the mean CT value of the whole lungs, density histogram analysis, density mask technique, and texture classification methods. Most of these methods offer good assessment of pulmonary functions, disease progression, and mortality. Each method has merits that can be used in clinical practice. One of the texture classification methods is reported to be superior to visual CT scoring by radiologist for correlation with pulmonary function and prediction of mortality. In this mini review, we summarize the current literature on computer-based CT image analysis of IPF and discuss its limitations and several future directions. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  18. Computed tomography scan based prediction of the vulnerable carotid plaque

    DEFF Research Database (Denmark)

    Diab, Hadi Mahmoud Haider; Rasmussen, Lars Melholt; Duvnjak, Stevo

    2017-01-01

    BACKGROUND: Primary to validate a commercial semi-automated computed tomography angiography (CTA) -software for vulnerable plaque detection compared to histology of carotid endarterectomy (CEA) specimens and secondary validating calcifications scores by in vivo CTA with ex vivo non......-contrast enhanced computed tomography (NCCT). METHODS: From January 2014 to October 2016 53 patients were included retrospectively, using a cross-sectional design. All patients underwent both CTA and CEA. Sixteen patients had their CEA specimen NCCT scanned. The semi-automated CTA software analyzed carotid stenosis...

  19. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  20. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  1. Voluminal modelling for the characterization of wastes packages by gamma emission computed tomography

    International Nuclear Information System (INIS)

    Pettier, J.L.; Thierry, R.

    2001-01-01

    The aim of this work is to model the measurement process used for multi-photon emission computed tomography on nuclear waste drum. Our model MEPHISTO (Multi-Energy PHoton Imagery through Segmented TOmography) takes into account all phenomena influencing gamma emergent flux and high resolution spectrometric measurements using an HpGe detector through a collimator aperture. These phenomena are absorption and Compton scattering of gamma photons in waste drum, geometrical blur, spatial and energetic response of the detector. The analysis of results shows better localisation and quantification performances compared with a Ray-Driven method. It proves the importance of an accurate modelization of collimated measurements to reduce noise and stabilize iterative image reconstructions. (authors)

  2. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  3. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    Science.gov (United States)

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  4. FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography-X-ray computed tomography.

    Science.gov (United States)

    Ale, Angelique; Ermolayev, Vladimir; Herzog, Eva; Cohrs, Christian; de Angelis, Martin Hrabé; Ntziachristos, Vasilis

    2012-06-01

    The development of hybrid optical tomography methods to improve imaging performance has been suggested over a decade ago and has been experimentally demonstrated in animals and humans. Here we examined in vivo performance of a camera-based hybrid fluorescence molecular tomography (FMT) system for 360° imaging combined with X-ray computed tomography (XCT). Offering an accurately co-registered, information-rich hybrid data set, FMT-XCT has new imaging possibilities compared to stand-alone FMT and XCT. We applied FMT-XCT to a subcutaneous 4T1 tumor mouse model, an Aga2 osteogenesis imperfecta model and a Kras lung cancer mouse model, using XCT information during FMT inversion. We validated in vivo imaging results against post-mortem planar fluorescence images of cryoslices and histology data. Besides offering concurrent anatomical and functional information, FMT-XCT resulted in the most accurate FMT performance to date. These findings indicate that addition of FMT optics into the XCT gantry may be a potent upgrade for small-animal XCT systems.

  5. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Schom, C.; Engelke, W.; Kopka, L.; Fischer, U.; Grabbe, E.

    1996-01-01

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.) [de

  6. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  7. Variability of four-dimensional computed tomography patient models

    NARCIS (Netherlands)

    Sonke, Jan-Jakob; Lebesque, Joos; van Herk, Marcel

    2008-01-01

    PURPOSE: To quantify the interfractional variability in lung tumor trajectory and mean position during the course of radiation therapy. METHODS AND MATERIALS: Repeat four-dimensional (4D) cone-beam computed tomography (CBCT) scans (median, nine scans/patient) routinely acquired during the course of

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  9. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  10. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  11. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches.

    Science.gov (United States)

    Nada, Rania M; Maal, Thomas J J; Breuning, K Hero; Bergé, Stefaan J; Mostafa, Yehya A; Kuijpers-Jagtman, Anne Marie

    2011-02-09

    Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16) for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27) for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.

  12. Cone-beam x-ray luminescence computed tomography based on x-ray absorption dosage

    Science.gov (United States)

    Liu, Tianshuai; Rong, Junyan; Gao, Peng; Zhang, Wenli; Liu, Wenlei; Zhang, Yuanke; Lu, Hongbing

    2018-02-01

    With the advances of x-ray excitable nanophosphors, x-ray luminescence computed tomography (XLCT) has become a promising hybrid imaging modality. In particular, a cone-beam XLCT (CB-XLCT) system has demonstrated its potential in in vivo imaging with the advantage of fast imaging speed over other XLCT systems. Currently, the imaging models of most XLCT systems assume that nanophosphors emit light based on the intensity distribution of x-ray within the object, not completely reflecting the nature of the x-ray excitation process. To improve the imaging quality of CB-XLCT, an imaging model that adopts an excitation model of nanophosphors based on x-ray absorption dosage is proposed in this study. To solve the ill-posed inverse problem, a reconstruction algorithm that combines the adaptive Tikhonov regularization method with the imaging model is implemented for CB-XLCT reconstruction. Numerical simulations and phantom experiments indicate that compared with the traditional forward model based on x-ray intensity, the proposed dose-based model could improve the image quality of CB-XLCT significantly in terms of target shape, localization accuracy, and image contrast. In addition, the proposed model behaves better in distinguishing closer targets, demonstrating its advantage in improving spatial resolution.

  13. Comparison of algebraic and analytical approaches to the formulation of the statistical model-based reconstruction problem for X-ray computed tomography.

    Science.gov (United States)

    Cierniak, Robert; Lorent, Anna

    2016-09-01

    The main aim of this paper is to investigate properties of our originally formulated statistical model-based iterative approach applied to the image reconstruction from projections problem which are related to its conditioning, and, in this manner, to prove a superiority of this approach over ones recently used by other authors. The reconstruction algorithm based on this conception uses a maximum likelihood estimation with an objective adjusted to the probability distribution of measured signals obtained from an X-ray computed tomography system with parallel beam geometry. The analysis and experimental results presented here show that our analytical approach outperforms the referential algebraic methodology which is explored widely in the literature and exploited in various commercial implementations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. A machine-learning approach for computation of fractional flow reserve from coronary computed tomography.

    Science.gov (United States)

    Itu, Lucian; Rapaka, Saikiran; Passerini, Tiziano; Georgescu, Bogdan; Schwemmer, Chris; Schoebinger, Max; Flohr, Thomas; Sharma, Puneet; Comaniciu, Dorin

    2016-07-01

    Fractional flow reserve (FFR) is a functional index quantifying the severity of coronary artery lesions and is clinically obtained using an invasive, catheter-based measurement. Recently, physics-based models have shown great promise in being able to noninvasively estimate FFR from patient-specific anatomical information, e.g., obtained from computed tomography scans of the heart and the coronary arteries. However, these models have high computational demand, limiting their clinical adoption. In this paper, we present a machine-learning-based model for predicting FFR as an alternative to physics-based approaches. The model is trained on a large database of synthetically generated coronary anatomies, where the target values are computed using the physics-based model. The trained model predicts FFR at each point along the centerline of the coronary tree, and its performance was assessed by comparing the predictions against physics-based computations and against invasively measured FFR for 87 patients and 125 lesions in total. Correlation between machine-learning and physics-based predictions was excellent (0.9994, P machine-learning algorithm with a sensitivity of 81.6%, a specificity of 83.9%, and an accuracy of 83.2%. The correlation was 0.729 (P assessment of FFR. Average execution time went down from 196.3 ± 78.5 s for the CFD model to ∼2.4 ± 0.44 s for the machine-learning model on a workstation with 3.4-GHz Intel i7 8-core processor. Copyright © 2016 the American Physiological Society.

  15. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  16. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  17. A computationally inexpensive model for estimating dimensional measurement uncertainty due to x-ray computed tomography instrument misalignments

    Science.gov (United States)

    Ametova, Evelina; Ferrucci, Massimiliano; Chilingaryan, Suren; Dewulf, Wim

    2018-06-01

    The recent emergence of advanced manufacturing techniques such as additive manufacturing and an increased demand on the integrity of components have motivated research on the application of x-ray computed tomography (CT) for dimensional quality control. While CT has shown significant empirical potential for this purpose, there is a need for metrological research to accelerate the acceptance of CT as a measuring instrument. The accuracy in CT-based measurements is vulnerable to the instrument geometrical configuration during data acquisition, namely the relative position and orientation of x-ray source, rotation stage, and detector. Consistency between the actual instrument geometry and the corresponding parameters used in the reconstruction algorithm is critical. Currently available procedures provide users with only estimates of geometrical parameters. Quantification and propagation of uncertainty in the measured geometrical parameters must be considered to provide a complete uncertainty analysis and to establish confidence intervals for CT dimensional measurements. In this paper, we propose a computationally inexpensive model to approximate the influence of errors in CT geometrical parameters on dimensional measurement results. We use surface points extracted from a computer-aided design (CAD) model to model discrepancies in the radiographic image coordinates assigned to the projected edges between an aligned system and a system with misalignments. The efficacy of the proposed method was confirmed on simulated and experimental data in the presence of various geometrical uncertainty contributors.

  18. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  19. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  20. Semiautomated four-dimensional computed tomography segmentation using deformable models

    International Nuclear Information System (INIS)

    Ragan, Dustin; Starkschall, George; McNutt, Todd; Kaus, Michael; Guerrero, Thomas; Stevens, Craig W.

    2005-01-01

    The purpose of this work is to demonstrate a proof of feasibility of the application of a commercial prototype deformable model algorithm to the problem of delineation of anatomic structures on four-dimensional (4D) computed tomography (CT) image data sets. We acquired a 4D CT image data set of a patient's thorax that consisted of three-dimensional (3D) image data sets from eight phases in the respiratory cycle. The contours of the right and left lungs, cord, heart, and esophagus were manually delineated on the end inspiration data set. An interactive deformable model algorithm, originally intended for deforming an atlas-based model surface to a 3D CT image data set, was applied in an automated fashion. Triangulations based on the contours generated on each phase were deformed to the CT data set on the succeeding phase to generate the contours on that phase. Deformation was propagated through the eight phases, and the contours obtained on the end inspiration data set were compared with the original manually delineated contours. Structures defined by high-density gradients, such as lungs, cord, and heart, were accurately reproduced, except in regions where other gradient boundaries may have confused the algorithm, such as near bronchi. The algorithm failed to accurately contour the esophagus, a soft-tissue structure completely surrounded by tissue of similar density, without manual interaction. This technique has the potential to facilitate contour delineation in 4D CT image data sets; and future evolution of the software is expected to improve the process

  1. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches.

    Directory of Open Access Journals (Sweden)

    Rania M Nada

    Full Text Available Superimposition of serial Cone Beam Computed Tomography (CBCT scans has become a valuable tool for three dimensional (3D assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16 for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27 for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.

  2. The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method.

    Science.gov (United States)

    Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian

    2016-05-01

    Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

    Science.gov (United States)

    Kinahan, Paul E; Hasegawa, Bruce H; Beyer, Thomas

    2003-07-01

    A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. Copyright 2003 Elsevier Inc. All rights reserved.

  4. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  5. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  6. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  7. Geometrical differences in target volumes based on 18F-fluorodeoxyglucose positron emission tomography/computed tomography and four-dimensional computed tomography maximum intensity projection images of primary thoracic esophageal cancer.

    Science.gov (United States)

    Guo, Y; Li, J; Wang, W; Zhang, Y; Wang, J; Duan, Y; Shang, D; Fu, Z

    2014-01-01

    The objective of the study was to compare geometrical differences of target volumes based on four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images of primary thoracic esophageal cancer for radiation treatment. Twenty-one patients with thoracic esophageal cancer sequentially underwent contrast-enhanced three-dimensional computed tomography (3DCT), 4DCT, and 18F-FDG PET/CT thoracic simulation scans during normal free breathing. The internal gross target volume defined as IGTVMIP was obtained by contouring on MIP images. The gross target volumes based on PET/CT images (GTVPET ) were determined with nine different standardized uptake value (SUV) thresholds and manual contouring: SUV≥2.0, 2.5, 3.0, 3.5 (SUVn); ≥20%, 25%, 30%, 35%, 40% of the maximum (percentages of SUVmax, SUVn%). The differences in volume ratio (VR), conformity index (CI), and degree of inclusion (DI) between IGTVMIP and GTVPET were investigated. The mean centroid distance between GTVPET and IGTVMIP ranged from 4.98 mm to 6.53 mm. The VR ranged from 0.37 to 1.34, being significantly (P<0.05) closest to 1 at SUV2.5 (0.94), SUV20% (1.07), or manual contouring (1.10). The mean CI ranged from 0.34 to 0.58, being significantly closest to 1 (P<0.05) at SUV2.0 (0.55), SUV2.5 (0.56), SUV20% (0.56), SUV25% (0.53), or manual contouring (0.58). The mean DI of GTVPET in IGTVMIP ranged from 0.61 to 0.91, and the mean DI of IGTVMIP in GTVPET ranged from 0.34 to 0.86. The SUV threshold setting of SUV2.5, SUV20% or manual contouring yields the best tumor VR and CI with internal-gross target volume contoured on MIP of 4DCT dataset, but 3DPET/CT and 4DCT MIP could not replace each other for motion encompassing target volume delineation for radiation treatment. © 2014 International Society for Diseases of the Esophagus.

  8. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  9. [Fabrication and accuracy research on 3D printing dental model based on cone beam computed tomography digital modeling].

    Science.gov (United States)

    Zhang, Hui-Rong; Yin, Le-Feng; Liu, Yan-Li; Yan, Li-Yi; Wang, Ning; Liu, Gang; An, Xiao-Li; Liu, Bin

    2018-04-01

    The aim of this study is to build a digital dental model with cone beam computed tomography (CBCT), to fabricate a virtual model via 3D printing, and to determine the accuracy of 3D printing dental model by comparing the result with a traditional dental cast. CBCT of orthodontic patients was obtained to build a digital dental model by using Mimics 10.01 and Geomagic studio software. The 3D virtual models were fabricated via fused deposition modeling technique (FDM). The 3D virtual models were compared with the traditional cast models by using a Vernier caliper. The measurements used for comparison included the width of each tooth, the length and width of the maxillary and mandibular arches, and the length of the posterior dental crest. 3D printing models had higher accuracy compared with the traditional cast models. The results of the paired t-test of all data showed that no statistically significant difference was observed between the two groups (P>0.05). Dental digital models built with CBCT realize the digital storage of patients' dental condition. The virtual dental model fabricated via 3D printing avoids traditional impression and simplifies the clinical examination process. The 3D printing dental models produced via FDM show a high degree of accuracy. Thus, these models are appropriate for clinical practice.

  10. Quantitative Assessment of Optical Coherence Tomography Imaging Performance with Phantom-Based Test Methods And Computational Modeling

    Science.gov (United States)

    Agrawal, Anant

    Optical coherence tomography (OCT) is a powerful medical imaging modality that uniquely produces high-resolution cross-sectional images of tissue using low energy light. Its clinical applications and technological capabilities have grown substantially since its invention about twenty years ago, but efforts have been limited to develop tools to assess performance of OCT devices with respect to the quality and content of acquired images. Such tools are important to ensure information derived from OCT signals and images is accurate and consistent, in order to support further technology development, promote standardization, and benefit public health. The research in this dissertation investigates new physical and computational models which can provide unique insights into specific performance characteristics of OCT devices. Physical models, known as phantoms, are fabricated and evaluated in the interest of establishing standardized test methods to measure several important quantities relevant to image quality. (1) Spatial resolution is measured with a nanoparticle-embedded phantom and model eye which together yield the point spread function under conditions where OCT is commonly used. (2) A multi-layered phantom is constructed to measure the contrast transfer function along the axis of light propagation, relevant for cross-sectional imaging capabilities. (3) Existing and new methods to determine device sensitivity are examined and compared, to better understand the detection limits of OCT. A novel computational model based on the finite-difference time-domain (FDTD) method, which simulates the physics of light behavior at the sub-microscopic level within complex, heterogeneous media, is developed to probe device and tissue characteristics influencing the information content of an OCT image. This model is first tested in simple geometric configurations to understand its accuracy and limitations, then a highly realistic representation of a biological cell, the retinal

  11. Operational modeling of dose and noise for computed tomography in a pediatric hospital

    International Nuclear Information System (INIS)

    Miller Clemente, Rafael A.; Perez Diaz, Marlen; Mora Reyes, Yudel; Rodriguez Garlobo, Maikel; Castillo Salazar, Rafael

    2008-01-01

    Noise becomes a critical factor in Computed Tomography (CT) because most detailed applications on soft tissue show a low contrast nature. Noise establishes an inferior limit to the contrast detectable by the observer. Various pixel noise models had been devised taking into account operational parameters on Single and Multi Detector Slice CT. The aim of this work was to obtain a predictive operational model for image noise addressed to pediatric protocols, taking into account scanning factors with a Single Slice CT unit dedicated to pediatric applications. A multiple linear regression model is proposed to predict noise in images of uniform phantoms equivalent to head and abdomen. A model for reported volumetric Computed Tomography Dose Index (CTDI VOL ) was obtained too for tradeoffs analysis approaching optimization purposes in pediatric applications. Eight independent variables were considered: phantom diameter, reconstruction mode, tube current, tube kVp, collimation, Field of View (FOV), reconstruction filter, and post processing filter. Results show good agreement with measurements, with adjusted coefficients of multiple determination of 0.936 and 0.744 for noise and CTDI VOL models respectively. Tube current, object diameter, collimation and reconstruction filters were the most influencing variables. The model application contributes to identify each factor's influence enhancing the operational possibilities approaching optimization of noise and dose tradeoffs. Acceptable noise levels and optimization strategies can be devised from models obtained towards lower tube current values combined with greater slice thickness and kVp taking into account the doses to pediatric patients. (author)

  12. Computed tomography of the vesicular glands: anatomical animal model (Oryctolagus cuniculus)

    International Nuclear Information System (INIS)

    Dimitrov, R.; Stamatova-Yovcheva, K.; Hamza, S.; Toneva, Y.

    2014-01-01

    Spiral CT is a non-invasive imaging method of choice for animal anatomical studies. The aim of the study was to establish the imaging anatomical features of the vesicular glands in the rabbit. Eight sexually mature healthy clinically male New Zealand rabbits of 18 months of age with body weight from 2.8 kg to 3.2 kg were used. The animals were anesthetized. As contrast medium Opti-ray350 was administrated. The computed tomography scan was complied with certain bone and soft tissue markers. For this purpose, a whole body multi-slice spiral computed tomography scanner was used. The both soft tissue glands were heterogeneous and relatively hyperdense structures, and defined in detail from the adjacent soft tissues. The urinary bladder neck was ventrally to the glands. Both vesicular glands were better differentiated each other when the rabbit is examined in abdominal recumbence. In dorsal recumbence the shape of the transversal image of the glandular finding was oval. In abdominal recumbence both the left and right soft tissue vesicular gland were defined. Transversal anatomical computed tomographic investigation of the rabbit vesicular gland is a detailed and definitive method, to study the normal morphology of these glands. Key words: Vesicular Gland. Helical Computed Tomography. Anatomy. Rabbit

  13. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  14. Discrete imaging models for three-dimensional optoacoustic tomography using radially symmetric expansion functions.

    Science.gov (United States)

    Wang, Kun; Schoonover, Robert W; Su, Richard; Oraevsky, Alexander; Anastasio, Mark A

    2014-05-01

    Optoacoustic tomography (OAT), also known as photoacoustic tomography, is an emerging computed biomedical imaging modality that exploits optical contrast and ultrasonic detection principles. Iterative image reconstruction algorithms that are based on discrete imaging models are actively being developed for OAT due to their ability to improve image quality by incorporating accurate models of the imaging physics, instrument response, and measurement noise. In this work, we investigate the use of discrete imaging models based on Kaiser-Bessel window functions for iterative image reconstruction in OAT. A closed-form expression for the pressure produced by a Kaiser-Bessel function is calculated, which facilitates accurate computation of the system matrix. Computer-simulation and experimental studies are employed to demonstrate the potential advantages of Kaiser-Bessel function-based iterative image reconstruction in OAT.

  15. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  16. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  18. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  19. Toward real-time diffuse optical tomography: accelerating light propagation modeling employing parallel computing on GPU and CPU

    Science.gov (United States)

    Doulgerakis, Matthaios; Eggebrecht, Adam; Wojtkiewicz, Stanislaw; Culver, Joseph; Dehghani, Hamid

    2017-12-01

    Parameter recovery in diffuse optical tomography is a computationally expensive algorithm, especially when used for large and complex volumes, as in the case of human brain functional imaging. The modeling of light propagation, also known as the forward problem, is the computational bottleneck of the recovery algorithm, whereby the lack of a real-time solution is impeding practical and clinical applications. The objective of this work is the acceleration of the forward model, within a diffusion approximation-based finite-element modeling framework, employing parallelization to expedite the calculation of light propagation in realistic adult head models. The proposed methodology is applicable for modeling both continuous wave and frequency-domain systems with the results demonstrating a 10-fold speed increase when GPU architectures are available, while maintaining high accuracy. It is shown that, for a very high-resolution finite-element model of the adult human head with ˜600,000 nodes, consisting of heterogeneous layers, light propagation can be calculated at ˜0.25 s/excitation source.

  20. Fuzzy modeling of electrical impedance tomography images of the lungs

    International Nuclear Information System (INIS)

    Tanaka, Harki; Ortega, Neli Regina Siqueira; Galizia, Mauricio Stanzione; Borges, Joao Batista; Amato, Marcelo Britto Passos

    2008-01-01

    Objectives: Aiming to improve the anatomical resolution of electrical impedance tomography images, we developed a fuzzy model based on electrical impedance tomography's high temporal resolution and on the functional pulmonary signals of perfusion and ventilation. Introduction: Electrical impedance tomography images carry information about both ventilation and perfusion. However, these images are difficult to interpret because of insufficient anatomical resolution, such that it becomes almost impossible to distinguish the heart from the lungs. Methods: Electrical impedance tomography data from an experimental animal model were collected during normal ventilation and apnoea while an injection of hypertonic saline was administered. The fuzzy model was elaborated in three parts: a modeling of the heart, the pulmonary ventilation map and the pulmonary perfusion map. Image segmentation was performed using a threshold method, and a ventilation/perfusion map was generated. Results: Electrical impedance tomography images treated by the fuzzy model were compared with the hypertonic saline injection method and computed tomography scan images, presenting good results. The average accuracy index was 0.80 when comparing the fuzzy modeled lung maps and the computed tomography scan lung mask. The average ROC curve area comparing a saline injection image and a fuzzy modeled pulmonary perfusion image was 0.77. Discussion: The innovative aspects of our work are the use of temporal information for the delineation of the heart structure and the use of two pulmonary functions for lung structure delineation. However, robustness of the method should be tested for the imaging of abnormal lung conditions. Conclusions: These results showed the adequacy of the fuzzy approach in treating the anatomical resolution uncertainties in electrical impedance tomography images. (author)

  1. Efficient non-negative constrained model-based inversion in optoacoustic tomography

    International Nuclear Information System (INIS)

    Ding, Lu; Luís Deán-Ben, X; Lutzweiler, Christian; Razansky, Daniel; Ntziachristos, Vasilis

    2015-01-01

    The inversion accuracy in optoacoustic tomography depends on a number of parameters, including the number of detectors employed, discrete sampling issues or imperfectness of the forward model. These parameters result in ambiguities on the reconstructed image. A common ambiguity is the appearance of negative values, which have no physical meaning since optical absorption can only be higher or equal than zero. We investigate herein algorithms that impose non-negative constraints in model-based optoacoustic inversion. Several state-of-the-art non-negative constrained algorithms are analyzed. Furthermore, an algorithm based on the conjugate gradient method is introduced in this work. We are particularly interested in investigating whether positive restrictions lead to accurate solutions or drive the appearance of errors and artifacts. It is shown that the computational performance of non-negative constrained inversion is higher for the introduced algorithm than for the other algorithms, while yielding equivalent results. The experimental performance of this inversion procedure is then tested in phantoms and small animals, showing an improvement in image quality and quantitativeness with respect to the unconstrained approach. The study performed validates the use of non-negative constraints for improving image accuracy compared to unconstrained methods, while maintaining computational efficiency. (paper)

  2. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  3. Grating-based X-ray Dark-field Computed Tomography of Living Mice.

    Science.gov (United States)

    Velroyen, A; Yaroshenko, A; Hahn, D; Fehringer, A; Tapfer, A; Müller, M; Noël, P B; Pauwels, B; Sasov, A; Yildirim, A Ö; Eickelberg, O; Hellbach, K; Auweter, S D; Meinel, F G; Reiser, M F; Bech, M; Pfeiffer, F

    2015-10-01

    Changes in x-ray attenuating tissue caused by lung disorders like emphysema or fibrosis are subtle and thus only resolved by high-resolution computed tomography (CT). The structural reorganization, however, is of strong influence for lung function. Dark-field CT (DFCT), based on small-angle scattering of x-rays, reveals such structural changes even at resolutions coarser than the pulmonary network and thus provides access to their anatomical distribution. In this proof-of-concept study we present x-ray in vivo DFCTs of lungs of a healthy, an emphysematous and a fibrotic mouse. The tomographies show excellent depiction of the distribution of structural - and thus indirectly functional - changes in lung parenchyma, on single-modality slices in dark field as well as on multimodal fusion images. Therefore, we anticipate numerous applications of DFCT in diagnostic lung imaging. We introduce a scatter-based Hounsfield Unit (sHU) scale to facilitate comparability of scans. In this newly defined sHU scale, the pathophysiological changes by emphysema and fibrosis cause a shift towards lower numbers, compared to healthy lung tissue.

  4. A way forward for the development of an exposure computational model to computed tomography dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, C.C., E-mail: cassio.c.ferreira@gmail.co [Nucleo de Fisica, Universidade Federal de Sergipe, Itabaiana-SE, CEP 49500-000 (Brazil); Galvao, L.A., E-mail: lailagalmeida@gmail.co [Departamento de Fisica, Universidade Federal de Sergipe, Sao Cristovao-SE, CEP 49100-000 (Brazil); Vieira, J.W., E-mail: jose.wilson59@uol.com.b [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco, Recife-PE, CEP 50740-540 (Brazil); Escola Politecnica de Pernambuco, Universidade de Pernambuco, Recife-PE, CEP 50720-001 (Brazil); Maia, A.F., E-mail: afmaia@ufs.b [Departamento de Fisica, Universidade Federal de Sergipe, Sao Cristovao-SE, CEP 49100-000 (Brazil)

    2011-04-15

    A way forward for the development of an exposure computational model to computed tomography dosimetry has been presented. In this way, an exposure computational model (ECM) for computed tomography (CT) dosimetry has been developed and validated through comparison with experimental results. For the development of the ECM, X-ray spectra generator codes have been evaluated and the head bow tie filter has been modelled through a mathematical equation. EGS4 and EGSnrc have been used for simulating the radiation transport by the ECM. Geometrical phantoms, commonly used in CT dosimetry, have been modelled by IDN software. MAX06 has also been used to simulate an adult male patient submitted for CT examinations. The evaluation of the X-ray spectra generator codes in CT dosimetry showed dependence with tube filtration (or HVL value). More generally, with the increment of total filtration (or HVL value) the X-raytbc becomes the best X-ray spectra generator code for CT dosimetry. The EGSnrc/X-raytbc combination has calculated C{sub 100,c} in better concordance with C{sub 100,c} measured in two different CT scanners. For a Toshiba CT scanner, the average percentage difference between the calculated C{sub 100,c} values and measured C{sub 100,c} values was 8.2%. Whilst for a GE CT scanner, the average percentage difference was 10.4%. By the measurements of air kerma through a prototype head bow tie filter a third-order exponential decay equation was found. C{sub 100,c} and C{sub 100,p} values calculated by the ECM are in good agreement with values measured at a specific CT scanner. A maximum percentage difference of 2% has been found in the PMMA CT head phantoms, demonstrating effective modelling of the head bow tie filter by the equation. The absorbed and effective doses calculated by the ECM developed in this work have been compared to those calculated by the ECM of Jones and Shrimpton for an adult male patient. For a head examination the absorbed dose values calculated by the

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  6. Pulmonary Nodule Volumetry at Different Low Computed Tomography Radiation Dose Levels With Hybrid and Model-Based Iterative Reconstruction: A Within Patient Analysis.

    Science.gov (United States)

    den Harder, Annemarie M; Willemink, Martin J; van Hamersvelt, Robbert W; Vonken, Evertjan P A; Schilham, Arnold M R; Lammers, Jan-Willem J; Luijk, Bart; Budde, Ricardo P J; Leiner, Tim; de Jong, Pim A

    2016-01-01

    The aim of the study was to determine the effects of dose reduction and iterative reconstruction (IR) on pulmonary nodule volumetry. In this prospective study, 25 patients scheduled for follow-up of pulmonary nodules were included. Computed tomography acquisitions were acquired at 4 dose levels with a median of 2.1, 1.2, 0.8, and 0.6 mSv. Data were reconstructed with filtered back projection (FBP), hybrid IR, and model-based IR. Volumetry was performed using semiautomatic software. At the highest dose level, more than 91% (34/37) of the nodules could be segmented, and at the lowest dose level, this was more than 83%. Thirty-three nodules were included for further analysis. Filtered back projection and hybrid IR did not lead to significant differences, whereas model-based IR resulted in lower volume measurements with a maximum difference of -11% compared with FBP at routine dose. Pulmonary nodule volumetry can be accurately performed at a submillisievert dose with both FBP and hybrid IR.

  7. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  8. Evaluation of computer-based computer tomography stratification against outcome models in connective tissue disease-related interstitial lung disease: a patient outcome study.

    Science.gov (United States)

    Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Brun, Anne Laure; Egashira, Ryoko; Karwoski, Ronald; Kokosi, Maria; Wells, Athol U; Hansell, David M

    2016-11-23

    To evaluate computer-based computer tomography (CT) analysis (CALIPER) against visual CT scoring and pulmonary function tests (PFTs) when predicting mortality in patients with connective tissue disease-related interstitial lung disease (CTD-ILD). To identify outcome differences between distinct CTD-ILD groups derived following automated stratification of CALIPER variables. A total of 203 consecutive patients with assorted CTD-ILDs had CT parenchymal patterns evaluated by CALIPER and visual CT scoring: honeycombing, reticular pattern, ground glass opacities, pulmonary vessel volume, emphysema, and traction bronchiectasis. CT scores were evaluated against pulmonary function tests: forced vital capacity, diffusing capacity for carbon monoxide, carbon monoxide transfer coefficient, and composite physiologic index for mortality analysis. Automated stratification of CALIPER-CT variables was evaluated in place of and alongside forced vital capacity and diffusing capacity for carbon monoxide in the ILD gender, age physiology (ILD-GAP) model using receiver operating characteristic curve analysis. Cox regression analyses identified four independent predictors of mortality: patient age (P < 0.0001), smoking history (P = 0.0003), carbon monoxide transfer coefficient (P = 0.003), and pulmonary vessel volume (P < 0.0001). Automated stratification of CALIPER variables identified three morphologically distinct groups which were stronger predictors of mortality than all CT and functional indices. The Stratified-CT model substituted automated stratified groups for functional indices in the ILD-GAP model and maintained model strength (area under curve (AUC) = 0.74, P < 0.0001), ILD-GAP (AUC = 0.72, P < 0.0001). Combining automated stratified groups with the ILD-GAP model (stratified CT-GAP model) strengthened predictions of 1- and 2-year mortality: ILD-GAP (AUC = 0.87 and 0.86, respectively); stratified CT-GAP (AUC = 0.89 and 0.88, respectively

  9. Computed Tomography Imaging of a Hip Prosthesis Using Iterative Model-Based Reconstruction and Orthopaedic Metal Artefact Reduction: A Quantitative Analysis.

    Science.gov (United States)

    Wellenberg, Ruud H H; Boomsma, Martijn F; van Osch, Jochen A C; Vlassenbroek, Alain; Milles, Julien; Edens, Mireille A; Streekstra, Geert J; Slump, Cornelis H; Maas, Mario

    To quantify the combined use of iterative model-based reconstruction (IMR) and orthopaedic metal artefact reduction (O-MAR) in reducing metal artefacts and improving image quality in a total hip arthroplasty phantom. Scans acquired at several dose levels and kVps were reconstructed with filtered back-projection (FBP), iterative reconstruction (iDose) and IMR, with and without O-MAR. Computed tomography (CT) numbers, noise levels, signal-to-noise-ratios and contrast-to-noise-ratios were analysed. Iterative model-based reconstruction results in overall improved image quality compared to iDose and FBP (P < 0.001). Orthopaedic metal artefact reduction is most effective in reducing severe metal artefacts improving CT number accuracy by 50%, 60%, and 63% (P < 0.05) and reducing noise by 1%, 62%, and 85% (P < 0.001) whereas improving signal-to-noise-ratios by 27%, 47%, and 46% (P < 0.001) and contrast-to-noise-ratios by 16%, 25%, and 19% (P < 0.001) with FBP, iDose, and IMR, respectively. The combined use of IMR and O-MAR strongly improves overall image quality and strongly reduces metal artefacts in the CT imaging of a total hip arthroplasty phantom.

  10. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  11. Global Seismic Imaging Based on Adjoint Tomography

    Science.gov (United States)

    Bozdag, E.; Lefebvre, M.; Lei, W.; Peter, D. B.; Smith, J. A.; Zhu, H.; Komatitsch, D.; Tromp, J.

    2013-12-01

    Our aim is to perform adjoint tomography at the scale of globe to image the entire planet. We have started elastic inversions with a global data set of 253 CMT earthquakes with moment magnitudes in the range 5.8 ≤ Mw ≤ 7 and used GSN stations as well as some local networks such as USArray, European stations, etc. Using an iterative pre-conditioned conjugate gradient scheme, we initially set the aim to obtain a global crustal and mantle model with confined transverse isotropy in the upper mantle. Global adjoint tomography has so far remained a challenge mainly due to computational limitations. Recent improvements in our 3D solvers (e.g., a GPU version) and access to high-performance computational centers (e.g., ORNL's Cray XK7 "Titan" system) now enable us to perform iterations with higher-resolution (T > 9 s) and longer-duration (200 min) simulations to accommodate high-frequency body waves and major-arc surface waves, respectively, which help improve data coverage. The remaining challenge is the heavy I/O traffic caused by the numerous files generated during the forward/adjoint simulations and the pre- and post-processing stages of our workflow. We improve the global adjoint tomography workflow by adopting the ADIOS file format for our seismic data as well as models, kernels, etc., to improve efficiency on high-performance clusters. Our ultimate aim is to use data from all available networks and earthquakes within the magnitude range of our interest (5.5 ≤ Mw ≤ 7) which requires a solid framework to manage big data in our global adjoint tomography workflow. We discuss the current status and future of global adjoint tomography based on our initial results as well as practical issues such as handling big data in inversions and on high-performance computing systems.

  12. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  13. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  14. General rigid motion correction for computed tomography imaging based on locally linear embedding

    Science.gov (United States)

    Chen, Mianyi; He, Peng; Feng, Peng; Liu, Baodong; Yang, Qingsong; Wei, Biao; Wang, Ge

    2018-02-01

    The patient motion can damage the quality of computed tomography images, which are typically acquired in cone-beam geometry. The rigid patient motion is characterized by six geometric parameters and are more challenging to correct than in fan-beam geometry. We extend our previous rigid patient motion correction method based on the principle of locally linear embedding (LLE) from fan-beam to cone-beam geometry and accelerate the computational procedure with the graphics processing unit (GPU)-based all scale tomographic reconstruction Antwerp toolbox. The major merit of our method is that we need neither fiducial markers nor motion-tracking devices. The numerical and experimental studies show that the LLE-based patient motion correction is capable of calibrating the six parameters of the patient motion simultaneously, reducing patient motion artifacts significantly.

  15. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  16. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  17. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  18. A compressed sensing based reconstruction algorithm for synchrotron source propagation-based X-ray phase contrast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Melli, Seyed Ali, E-mail: sem649@mail.usask.ca [Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK (Canada); Wahid, Khan A. [Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK (Canada); Babyn, Paul [Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK (Canada); Montgomery, James [College of Medicine, University of Saskatchewan, Saskatoon, SK (Canada); Snead, Elisabeth [Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK (Canada); El-Gayed, Ali [College of Medicine, University of Saskatchewan, Saskatoon, SK (Canada); Pettitt, Murray; Wolkowski, Bailey [College of Agriculture and Bioresources, University of Saskatchewan, Saskatoon, SK (Canada); Wesolowski, Michal [Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK (Canada)

    2016-01-11

    Synchrotron source propagation-based X-ray phase contrast computed tomography is increasingly used in pre-clinical imaging. However, it typically requires a large number of projections, and subsequently a large radiation dose, to produce high quality images. To improve the applicability of this imaging technique, reconstruction algorithms that can reduce the radiation dose and acquisition time without degrading image quality are needed. The proposed research focused on using a novel combination of Douglas–Rachford splitting and randomized Kaczmarz algorithms to solve large-scale total variation based optimization in a compressed sensing framework to reconstruct 2D images from a reduced number of projections. Visual assessment and quantitative performance evaluations of a synthetic abdomen phantom and real reconstructed image of an ex-vivo slice of canine prostate tissue demonstrate that the proposed algorithm is competitive in reconstruction process compared with other well-known algorithms. An additional potential benefit of reducing the number of projections would be reduction of time for motion artifact to occur if the sample moves during image acquisition. Use of this reconstruction algorithm to reduce the required number of projections in synchrotron source propagation-based X-ray phase contrast computed tomography is an effective form of dose reduction that may pave the way for imaging of in-vivo samples.

  19. Toward real-time diffuse optical tomography: accelerating light propagation modeling employing parallel computing on GPU and CPU.

    Science.gov (United States)

    Doulgerakis, Matthaios; Eggebrecht, Adam; Wojtkiewicz, Stanislaw; Culver, Joseph; Dehghani, Hamid

    2017-12-01

    Parameter recovery in diffuse optical tomography is a computationally expensive algorithm, especially when used for large and complex volumes, as in the case of human brain functional imaging. The modeling of light propagation, also known as the forward problem, is the computational bottleneck of the recovery algorithm, whereby the lack of a real-time solution is impeding practical and clinical applications. The objective of this work is the acceleration of the forward model, within a diffusion approximation-based finite-element modeling framework, employing parallelization to expedite the calculation of light propagation in realistic adult head models. The proposed methodology is applicable for modeling both continuous wave and frequency-domain systems with the results demonstrating a 10-fold speed increase when GPU architectures are available, while maintaining high accuracy. It is shown that, for a very high-resolution finite-element model of the adult human head with ∼600,000 nodes, consisting of heterogeneous layers, light propagation can be calculated at ∼0.25  s/excitation source. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  20. Value of radio density determined by enhanced computed tomography for the differential diagnosis of lung masses

    International Nuclear Information System (INIS)

    Xie, Min

    2011-01-01

    Lung masses are often difficult to differentiate when their clinical symptoms and shapes or densities on computed tomography images are similar. However, with different pathological contents, they may appear differently on plain and enhanced computed tomography. Objectives: To determine the value of enhanced computed tomography for the differential diagnosis of lung masses based on the differences in radio density with and without enhancement. Patients and Methods: Thirty-six patients with lung cancer, 36 with pulmonary tuberculosis and 10 with inflammatory lung pseudo tumors diagnosed by computed tomography and confirmed by pathology in our hospital were selected. The mean ±SD radio densities of lung masses in the three groups of patients were calculated based on the results of plain and enhanced computed tomography. Results: There were no significant differences in the radio densities of the masses detected by plain computed tomography among patients with inflammatory lung pseudo tumors, tuberculosis and lung cancer (P> 0.05). However, there were significant differences (P< 0.01)between all the groups in terms of radio densities of masses detected by enhanced computed tomography. Conclusions: The radio densities of lung masses detected by enhanced computed tomography could potentially be used to differentiate between lung cancer, pulmonary tuberculosis and inflammatory lung pseudo tumors.

  1. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  2. Comparison of denture models by means of micro computed tomography

    Science.gov (United States)

    Vögtlin, Christoph; Schulz, Georg; Deyhle, Hans; Jäger, Kurt; Liebrich, Thomas; Weikert, Sascha; Müller, Bert

    2012-10-01

    The production of dental inlays and crowns requires precise information on patients' teeth morphology. The conventional method is the preparation of impressions using mold materials, e.g. a silicone impression material. The disadvantage of this technique is the human choke impulse and the flavor of the material. These discomforts can be avoided by methods where a three-dimensional scanner is used for recording the teeth morphology. The present study reveals the accuracy of three model types, namely conventional impression, rapid prototyping using an oral scanner C.O.S., 3M (Schweiz) AG and milling from a proprietary resin using the oral scanner iTero, Straumann Holding AG. For each method five models were fabricated from a steel reference (standard). Using a nanotom m (phoenixǀx-ray, GE Sensing and Inspection Technologies GmbH), three-dimensional micro computed tomography data sets of the standard and the 15 models were recorded and landmark distances within the data sets were measured with sub-pixel accuracy. To verify these results a coordinate measuring machine (Leitz PMM 864, Hexagon Metrology GmbH) based on tactile detection was used for the measurement of the landmark distances, and a correction of the distances measured by the nanotom m was arranged. The nanotom data sets of the 15 models were also compared to the standard by means of a non-rigid registration algorithm. The calculated deformation field exhibited mean pixel displacement values of (0.19 +/- 0.09) mm for the C.O.S. models, (0.12 +/- 0.07) mm for the gypsum models and (0.19 +/- 0.12) mm for the i-Tero models.

  3. The role of computed tomography in the laryngeal injury

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1984-01-01

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results

  4. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  5. Three Dimensional Digital Sieving of Asphalt Mixture Based on X-ray Computed Tomography

    OpenAIRE

    Chichun Hu; Jiexian Ma; M. Emin Kutay

    2017-01-01

    In order to perform three-dimensional digital sieving based on X-ray computed tomography images, the definition of digital sieve size (DSS) was proposed, which was defined as the minimum length of the minimum bounding squares of all possible orthographic projections of an aggregate. The corresponding program was developed to reconstruct aggregate structure and to obtain DSS. Laboratory experiments consisting of epoxy-filled aggregate specimens were conducted to investigate the difference betw...

  6. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  7. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography.

    Science.gov (United States)

    Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P

    2014-11-01

    Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  8. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended to...

  9. Estimation of computed tomography dose index in cone beam computed tomography: MOSFET measurements and Monte Carlo simulations.

    Science.gov (United States)

    Kim, Sangroh; Yoshizumi, Terry; Toncheva, Greta; Yoo, Sua; Yin, Fang-Fang; Frush, Donald

    2010-05-01

    To address the lack of accurate dose estimation method in cone beam computed tomography (CBCT), we performed point dose metal oxide semiconductor field-effect transistor (MOSFET) measurements and Monte Carlo (MC) simulations. A Varian On-Board Imager (OBI) was employed to measure point doses in the polymethyl methacrylate (PMMA) CT phantoms with MOSFETs for standard and low dose modes. A MC model of the OBI x-ray tube was developed using BEAMnrc/EGSnrc MC system and validated by the half value layer, x-ray spectrum and lateral and depth dose profiles. We compared the weighted computed tomography dose index (CTDIw) between MOSFET measurements and MC simulations. The CTDIw was found to be 8.39 cGy for the head scan and 4.58 cGy for the body scan from the MOSFET measurements in standard dose mode, and 1.89 cGy for the head and 1.11 cGy for the body in low dose mode, respectively. The CTDIw from MC compared well to the MOSFET measurements within 5% differences. In conclusion, a MC model for Varian CBCT has been established and this approach may be easily extended from the CBCT geometry to multi-detector CT geometry.

  10. Automated method for structural segmentation of nasal airways based on cone beam computed tomography

    Science.gov (United States)

    Tymkovych, Maksym Yu.; Avrunin, Oleg G.; Paliy, Victor G.; Filzow, Maksim; Gryshkov, Oleksandr; Glasmacher, Birgit; Omiotek, Zbigniew; DzierŻak, RóŻa; Smailova, Saule; Kozbekova, Ainur

    2017-08-01

    The work is dedicated to the segmentation problem of human nasal airways using Cone Beam Computed Tomography. During research, we propose a specialized approach of structured segmentation of nasal airways. That approach use spatial information, symmetrisation of the structures. The proposed stages can be used for construction a virtual three dimensional model of nasal airways and for production full-scale personalized atlases. During research we build the virtual model of nasal airways, which can be used for construction specialized medical atlases and aerodynamics researches.

  11. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  12. Slice image pretreatment for cone-beam computed tomography based on adaptive filter

    International Nuclear Information System (INIS)

    Huang Kuidong; Zhang Dinghua; Jin Yanfang

    2009-01-01

    According to the noise properties and the serial slice image characteristics in Cone-Beam Computed Tomography (CBCT) system, a slice image pretreatment for CBCT based on adaptive filter was proposed. The judging criterion for the noise is established firstly. All pixels are classified into two classes: adaptive center weighted modified trimmed mean (ACWMTM) filter is used for the pixels corrupted by Gauss noise and adaptive median (AM) filter is used for the pixels corrupted by impulse noise. In ACWMTM filtering algorithm, the estimated Gauss noise standard deviation in the current slice image with offset window is replaced by the estimated standard deviation in the adjacent slice image to the current with the corresponding window, so the filtering accuracy of the serial images is improved. The pretreatment experiment on CBCT slice images of wax model of hollow turbine blade shows that the method makes a good performance both on eliminating noises and on protecting details. (authors)

  13. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung

    2001-01-01

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  14. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  15. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  16. Computed tomography landmark-based semi-automated mesh morphing and mapping techniques: generation of patient specific models of the human pelvis without segmentation.

    Science.gov (United States)

    Salo, Zoryana; Beek, Maarten; Wright, David; Whyne, Cari Marisa

    2015-04-13

    Current methods for the development of pelvic finite element (FE) models generally are based upon specimen specific computed tomography (CT) data. This approach has traditionally required segmentation of CT data sets, which is time consuming and necessitates high levels of user intervention due to the complex pelvic anatomy. The purpose of this research was to develop and assess CT landmark-based semi-automated mesh morphing and mapping techniques to aid the generation and mechanical analysis of specimen-specific FE models of the pelvis without the need for segmentation. A specimen-specific pelvic FE model (source) was created using traditional segmentation methods and morphed onto a CT scan of a different (target) pelvis using a landmark-based method. The morphed model was then refined through mesh mapping by moving the nodes to the bone boundary. A second target model was created using traditional segmentation techniques. CT intensity based material properties were assigned to the morphed/mapped model and to the traditionally segmented target models. Models were analyzed to evaluate their geometric concurrency and strain patterns. Strains generated in a double-leg stance configuration were compared to experimental strain gauge data generated from the same target cadaver pelvis. CT landmark-based morphing and mapping techniques were efficiently applied to create a geometrically multifaceted specimen-specific pelvic FE model, which was similar to the traditionally segmented target model and better replicated the experimental strain results (R(2)=0.873). This study has shown that mesh morphing and mapping represents an efficient validated approach for pelvic FE model generation without the need for segmentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  18. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  19. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  20. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  1. Skull base osteomyelitis in otitis externa: The utility of triphasic and single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Gupta, Ashok Kumar; Panda, Naresh Kumar; Das, Ashim; Mittal, Bhagwant Rai

    2013-01-01

    Skull base osteomyelitis (SBO) refers to infection that has spread beyond the external auditory canal to the base of the skull in advanced stages of otitis externa. Clinically, it may be difficult to differentiate SBO from severe otitis externa without bony involvement. This study was performed to determine the role of three phase bone scintigraphy (TPBS) and single photon emission tomography/computed tomography (SPECT/CT) in detecting SBO. We retrospectively analyzed records of 20 patients (14 M, 6 F) with otitis externa and suspected SBO. TPBS and SPECT/CT of the skull were performed. Findings were correlated with clinical, laboratory and diagnostic CT scan findings. All patients were diabetic with elevated erythrocyte sedimentation rate. A total of 18 patients had bilateral and two unilateral symptoms. Cranial nerves were involved in eight patients and microbiological culture of ear discharge fluid positive in seven. Early images showed increased temporal vascularity in nine patients and increased soft-tissue uptake in 10, while delayed images showed increased bone uptake in 19/20 patients. Localized abnormal tracer uptake was shown by SPECT/CT in the mastoid temporal (15), petrous (11), sphenoid (3) and zygomatic (1) and showed destructive changes in five. Thus, TPBS was found positive for SBO in 10/20 patients and changed the management in four. Our study suggests that TPBS with SPECT/CT is a useful non-invasive investigation for detection of SBO in otitis externa

  2. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  3. [Treatment choice in dacryostenosis based on single-photon emission computed tomography and X-ray computed tomography findings].

    Science.gov (United States)

    At'kova, E L; Yartsev, V D; Tomashevskiy, I O; Krakhovetskiy, N N

    2016-01-01

    To develop surgical indications in dacryostenosis within the vertical portion of lacrimal pathways that would consider findings of single-photon emission computed tomography (SPECT) combined with X-ray computed tomography (CT). A total of 96 patients with isolated vertical-portion dacryostenosis (127 cases) were enrolled. The examination included collecting Munk's scores for epiphora, optical coherence tomography of the lower tear meniscus, lacrimal scintigraphy, and SPECT/CT. Group 1 (40 cases) was composed of patients with lacrimal obstruction on CT, group 2 (87 cases) - of those whose lacrimal pathways proved passable. There were also 3 patients (4 cases) from group 1, whose lacrimal pathways, despite being blocked on CT, were still passable on SPECT. Surgeries performed in group 1 were endoscopic endonasal dacryocystorhinostomy (DCR) (36 cases) and pathways recanalization with bicanalicular intubation and balloon dacryoplasty (DCP) (4 cases). In group 2, all patients (87 cases) underwent recanalization with bicanalicular intubation (supplemented with balloon DCP in 32 cases). Surgical results were evaluated 8-12 months after the treatment. In group 2, particular attention was paid to the concordance in locations of dacryostenosis provided by CT and SPECT scans. Favorable outcomes of endoscopic endonasal DCR were obtained in as many as 32 cases from group 1 (88.9%), while in 4 cases (12.1%) the condition relapsed. Of those patients whose stenosis was not complete on SPECT, 3 cases (75.0%) improved, 1 (25.0%) - relapsed. In group 2, favorable outcomes were obtained in 65 cases (74.7%), relapses were 22 (25.3%). A high concordance in stenosis locations by CT and SPECT was noted in 60 cases of those who improved (92.3%) and 3 cases of those who relapsed (13.6%). The value of information provided by SPECT/CT has proved high in patients with nasolacrimal duct stenosis or obstruction. A combined scan allows to establish causal relationships between anatomical changes

  4. A synchrotron-based local computed tomography combined with data-constrained modelling approach for quantitative analysis of anthracite coal microstructure

    International Nuclear Information System (INIS)

    Chen, Wen Hao; Yang, Sam Y. S.; Xiao, Ti Qiao; Mayo, Sherry C.; Wang, Yu Dan; Wang, Hai Peng

    2014-01-01

    A quantitative local computed tomography combined with data-constrained modelling has been developed. The method could improve distinctly the spatial resolution and the composition resolution in a sample larger than the field of view, for quantitative characterization of three-dimensional distributions of material compositions and void. Quantifying three-dimensional spatial distributions of pores and material compositions in samples is a key materials characterization challenge, particularly in samples where compositions are distributed across a range of length scales, and where such compositions have similar X-ray absorption properties, such as in coal. Consequently, obtaining detailed information within sub-regions of a multi-length-scale sample by conventional approaches may not provide the resolution and level of detail one might desire. Herein, an approach for quantitative high-definition determination of material compositions from X-ray local computed tomography combined with a data-constrained modelling method is proposed. The approach is capable of dramatically improving the spatial resolution and enabling finer details within a region of interest of a sample larger than the field of view to be revealed than by using conventional techniques. A coal sample containing distributions of porosity and several mineral compositions is employed to demonstrate the approach. The optimal experimental parameters are pre-analyzed. The quantitative results demonstrated that the approach can reveal significantly finer details of compositional distributions in the sample region of interest. The elevated spatial resolution is crucial for coal-bed methane reservoir evaluation and understanding the transformation of the minerals during coal processing. The method is generic and can be applied for three-dimensional compositional characterization of other materials

  5. Material Characterization and Geometric Segmentation of a Composite Structure Using Microfocus X-Ray Computed Tomography Image-Based Finite Element Modeling

    Science.gov (United States)

    Abdul-Aziz, Ali; Roth, D. J.; Cotton, R.; Studor, George F.; Christiansen, Eric; Young, P. C.

    2011-01-01

    This study utilizes microfocus x-ray computed tomography (CT) slice sets to model and characterize the damage locations and sizes in thermal protection system materials that underwent impact testing. ScanIP/FE software is used to visualize and process the slice sets, followed by mesh generation on the segmented volumetric rendering. Then, the local stress fields around several of the damaged regions are calculated for realistic mission profiles that subject the sample to extreme temperature and other severe environmental conditions. The resulting stress fields are used to quantify damage severity and make an assessment as to whether damage that did not penetrate to the base material can still result in catastrophic failure of the structure. It is expected that this study will demonstrate that finite element modeling based on an accurate three-dimensional rendered model from a series of CT slices is an essential tool to quantify the internal macroscopic defects and damage of a complex system made out of thermal protection material. Results obtained showing details of segmented images; three-dimensional volume-rendered models, finite element meshes generated, and the resulting thermomechanical stress state due to impact loading for the material are presented and discussed. Further, this study is conducted to exhibit certain high-caliber capabilities that the nondestructive evaluation (NDE) group at NASA Glenn Research Center can offer to assist in assessing the structural durability of such highly specialized materials so improvements in their performance and capacities to handle harsh operating conditions can be made.

  6. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Moraes, Everton; Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase; Gazzoni, Fernando; Lopes, Luis Felipe Dias

    2007-01-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  9. Accuracy of a computed tomography scanning procedure to manufacture digital models.

    NARCIS (Netherlands)

    Darroudi, A.M.; Kuijpers-Jagtman, A.M.; Ongkosuwito, E.M.; Suttorp, C.M.; Bronkhorst, E.M.; Breuning, K.H.

    2017-01-01

    INTRODUCTION: Accurate articulation of the digital dental casts is crucial in orthodontic diagnosis and treatment planning. We aimed to determine the accuracy of manufacturing digital dental casts from computed tomography scanning of plaster casts regarding linear dimensions and interarch

  10. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  11. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  12. Geometrical analysis of woven fabric microstructure based on micron-resolution computed tomography data

    Science.gov (United States)

    Krieger, Helga; Seide, Gunnar; Gries, Thomas; Stapleton, Scott E.

    2018-04-01

    The global mechanical properties of textiles such as elasticity and strength, as well as transport properties such as permeability depend strongly on the microstructure of the textile. Textiles are heterogeneous structures with highly anisotropic material properties, including local fiber orientation and local fiber volume fraction. In this paper, an algorithm is presented to generate a virtual 3D-model of a woven fabric architecture with information about the local fiber orientation and the local fiber volume fraction. The geometric data of the woven fabric impregnated with resin was obtained by micron-resolution computed tomography (μCT). The volumetric μCT-scan was discretized into cells and the microstructure of each cell was analyzed and homogenized. Furthermore, the discretized data was used to calculate the local permeability tensors of each cell. An example application of the analyzed data is the simulation of the resin flow through a woven fabric based on the determined local permeability tensors and on Darcy's law. The presented algorithm is an automated and robust method of going from μCT-scans to structural or flow models.

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  14. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  15. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  16. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  17. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  18. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  19. Computer tomography in complex diagnosis of laryngeal cancer

    International Nuclear Information System (INIS)

    Savin, A.A.

    1999-01-01

    To specify the role of computer tomography in the diagnosis of malignant of the larynx. Forty-two patients with suspected laryngeal tumors were examined: 38 men and 4 women aged 41-68 years. X-ray examinations included traditional immediate tomography of the larynx. Main X-ray and computer tomographic symptoms of laryngeal tumors of different localizations are described. It is shown that the use of computer tomography in complex diagnosis of laryngeal cancer permits an objective assessment of the tumor, its structure and dissemination, and of the regional lymph nodes [ru

  20. Computed Tomography Observer Agreement in Staging Malignant Lymphoma

    NARCIS (Netherlands)

    de Jong, Antoinette; Kwee, Thomas C.; Quarles van Ufford, Henriëtte M. E.; Beek, Frederik J. A.; Quekel, Lorentz G. B. A.; de Klerk, John M. H.; Zijlstra, Josée M.; Fijnheer, Rob; Ludwig, Inge; Kersten, Marie José; Stoker, Jaap; Nievelstein, Rutger A. J.

    2016-01-01

    To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann

  1. Evaluation of valvular heart diseases with computed tomography

    International Nuclear Information System (INIS)

    Tomoda, Haruo; Hoshiai, Mitsumoto; Matsuyama, Seiya

    1982-01-01

    Forty-two patients with valvular heart diseases were studied with a third-generation computed tomographic system. The cardiac chambers (the atria and ventricles) were evaluated semiquantitatively, and valvular calcification was easily detected with computed tomography. Computed tomography was most valuable in revealing left atrial thrombi which were not identified by other diagnostic procedures in some cases. (author)

  2. Cyst-based measurements for assessing lymphangioleiomyomatosis in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lo, P., E-mail: pechinlo@mednet.edu.ucla; Brown, M. S.; Kim, H.; Kim, H.; Goldin, J. G. [Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California 90024 (United States); Argula, R.; Strange, C. [Division of Pulmonary and Critical Care Medicine, Medical University of South Carolina, Charleston, South Carolina 29425 (United States)

    2015-05-15

    Purpose: To investigate the efficacy of a new family of measurements made on individual pulmonary cysts extracted from computed tomography (CT) for assessing the severity of lymphangioleiomyomatosis (LAM). Methods: CT images were analyzed using thresholding to identify a cystic region of interest from chest CT of LAM patients. Individual cysts were then extracted from the cystic region by the watershed algorithm, which separates individual cysts based on subtle edges within the cystic regions. A family of measurements were then computed, which quantify the amount, distribution, and boundary appearance of the cysts. Sequential floating feature selection was used to select a small subset of features for quantification of the severity of LAM. Adjusted R{sup 2} from multiple linear regression and R{sup 2} from linear regression against measurements from spirometry were used to compare the performance of our proposed measurements with currently used density based CT measurements in the literature, namely, the relative area measure and the D measure. Results: Volumetric CT data, performed at total lung capacity and residual volume, from a total of 49 subjects enrolled in the MILES trial were used in our study. Our proposed measures had adjusted R{sup 2} ranging from 0.42 to 0.59 when regressing against the spirometry measures, with p < 0.05. For previously used density based CT measurements in the literature, the best R{sup 2} was 0.46 (for only one instance), with the majority being lower than 0.3 or p > 0.05. Conclusions: The proposed family of CT-based cyst measurements have better correlation with spirometric measures than previously used density based CT measurements. They show potential as a sensitive tool for quantitatively assessing the severity of LAM.

  3. Hybrid model based unified scheme for endoscopic Cerenkov and radio-luminescence tomography: Simulation demonstration

    Science.gov (United States)

    Wang, Lin; Cao, Xin; Ren, Qingyun; Chen, Xueli; He, Xiaowei

    2018-05-01

    Cerenkov luminescence imaging (CLI) is an imaging method that uses an optical imaging scheme to probe a radioactive tracer. Application of CLI with clinically approved radioactive tracers has opened an opportunity for translating optical imaging from preclinical to clinical applications. Such translation was further improved by developing an endoscopic CLI system. However, two-dimensional endoscopic imaging cannot identify accurate depth and obtain quantitative information. Here, we present an imaging scheme to retrieve the depth and quantitative information from endoscopic Cerenkov luminescence tomography, which can also be applied for endoscopic radio-luminescence tomography. In the scheme, we first constructed a physical model for image collection, and then a mathematical model for characterizing the luminescent light propagation from tracer to the endoscopic detector. The mathematical model is a hybrid light transport model combined with the 3rd order simplified spherical harmonics approximation, diffusion, and radiosity equations to warrant accuracy and speed. The mathematical model integrates finite element discretization, regularization, and primal-dual interior-point optimization to retrieve the depth and the quantitative information of the tracer. A heterogeneous-geometry-based numerical simulation was used to explore the feasibility of the unified scheme, which demonstrated that it can provide a satisfactory balance between imaging accuracy and computational burden.

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  6. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  7. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  8. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  9. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  10. Multi-GPU Jacobian accelerated computing for soft-field tomography

    International Nuclear Information System (INIS)

    Borsic, A; Attardo, E A; Halter, R J

    2012-01-01

    Image reconstruction in soft-field tomography is based on an inverse problem formulation, where a forward model is fitted to the data. In medical applications, where the anatomy presents complex shapes, it is common to use finite element models (FEMs) to represent the volume of interest and solve a partial differential equation that models the physics of the system. Over the last decade, there has been a shifting interest from 2D modeling to 3D modeling, as the underlying physics of most problems are 3D. Although the increased computational power of modern computers allows working with much larger FEM models, the computational time required to reconstruct 3D images on a fine 3D FEM model can be significant, on the order of hours. For example, in electrical impedance tomography (EIT) applications using a dense 3D FEM mesh with half a million elements, a single reconstruction iteration takes approximately 15–20 min with optimized routines running on a modern multi-core PC. It is desirable to accelerate image reconstruction to enable researchers to more easily and rapidly explore data and reconstruction parameters. Furthermore, providing high-speed reconstructions is essential for some promising clinical application of EIT. For 3D problems, 70% of the computing time is spent building the Jacobian matrix, and 25% of the time in forward solving. In this work, we focus on accelerating the Jacobian computation by using single and multiple GPUs. First, we discuss an optimized implementation on a modern multi-core PC architecture and show how computing time is bounded by the CPU-to-memory bandwidth; this factor limits the rate at which data can be fetched by the CPU. Gains associated with the use of multiple CPU cores are minimal, since data operands cannot be fetched fast enough to saturate the processing power of even a single CPU core. GPUs have much faster memory bandwidths compared to CPUs and better parallelism. We are able to obtain acceleration factors of 20 times

  11. Multi-GPU Jacobian accelerated computing for soft-field tomography.

    Science.gov (United States)

    Borsic, A; Attardo, E A; Halter, R J

    2012-10-01

    Image reconstruction in soft-field tomography is based on an inverse problem formulation, where a forward model is fitted to the data. In medical applications, where the anatomy presents complex shapes, it is common to use finite element models (FEMs) to represent the volume of interest and solve a partial differential equation that models the physics of the system. Over the last decade, there has been a shifting interest from 2D modeling to 3D modeling, as the underlying physics of most problems are 3D. Although the increased computational power of modern computers allows working with much larger FEM models, the computational time required to reconstruct 3D images on a fine 3D FEM model can be significant, on the order of hours. For example, in electrical impedance tomography (EIT) applications using a dense 3D FEM mesh with half a million elements, a single reconstruction iteration takes approximately 15-20 min with optimized routines running on a modern multi-core PC. It is desirable to accelerate image reconstruction to enable researchers to more easily and rapidly explore data and reconstruction parameters. Furthermore, providing high-speed reconstructions is essential for some promising clinical application of EIT. For 3D problems, 70% of the computing time is spent building the Jacobian matrix, and 25% of the time in forward solving. In this work, we focus on accelerating the Jacobian computation by using single and multiple GPUs. First, we discuss an optimized implementation on a modern multi-core PC architecture and show how computing time is bounded by the CPU-to-memory bandwidth; this factor limits the rate at which data can be fetched by the CPU. Gains associated with the use of multiple CPU cores are minimal, since data operands cannot be fetched fast enough to saturate the processing power of even a single CPU core. GPUs have much faster memory bandwidths compared to CPUs and better parallelism. We are able to obtain acceleration factors of 20

  12. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  19. Coronary Computed Tomography Angiography Derived Fractional Flow Reserve and Plaque Stress

    DEFF Research Database (Denmark)

    Nørgaard, Bjarne Linde; Leipsic, Jonathon; Koo, Bon-Kwon

    2016-01-01

    Fractional flow reserve (FFR) measured during invasive coronary angiography is an independent prognosticator in patients with coronary artery disease and the gold standard for decision making in coronary revascularization. The integration of computational fluid dynamics and quantitative anatomic...... and physiologic modeling now enables simulation of patient-specific hemodynamic parameters including blood velocity, pressure, pressure gradients, and FFR from standard acquired coronary computed tomography (CT) datasets. In this review article, we describe the potential impact on clinical practice...... and the science behind noninvasive coronary computed tomography (CT) angiography derived fractional flow reserve (FFRCT) as well as future applications of this technology in treatment planning and quantifying forces on atherosclerotic plaques....

  20. Segmentation process significantly influences the accuracy of 3D surface models derived from cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Schepers, Rutger H; Gerrits, Pieter; Ren, Yijin

    AIMS: To assess the accuracy of surface models derived from 3D cone beam computed tomography (CBCT) with two different segmentation protocols. MATERIALS AND METHODS: Seven fresh-frozen cadaver heads were used. There was no conflict of interests in this study. CBCT scans were made of the heads and 3D

  1. Computed tomography in children: multicenter cohort study design for the evaluation of cancer risk

    International Nuclear Information System (INIS)

    Krille, L.; Jahnen, A.; Mildenberger, P.; Schneider, K.; Weisser, G.; Zeeb, H.; Blettner, M.

    2011-01-01

    Exposure to ionizing radiation is a known risk factor for cancer. Cancer risk is highest after exposure in childhood. The computed tomography is the major contributor to the average, individual radiation exposure. Until now the association has been addressed only in statistical modeling. We present the first feasible study design on childhood cancer risk after exposure to computed tomography.

  2. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Marchiori, Edson; Oliveira, Hugo

    2010-01-01

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  3. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  4. The Impact of Computed Tomography on Decision Making in Tibial Plateau Fractures.

    Science.gov (United States)

    Castiglia, Marcello Teixeira; Nogueira-Barbosa, Marcello Henrique; Messias, Andre Marcio Vieira; Salim, Rodrigo; Fogagnolo, Fabricio; Schatzker, Joseph; Kfuri, Mauricio

    2018-02-14

    Schatzker introduced one of the most used classification systems for tibial plateau fractures, based on plain radiographs. Computed tomography brought to attention the importance of coronal plane-oriented fractures. The goal of our study was to determine if the addition of computed tomography would affect the decision making of surgeons who usually use the Schatzker classification to assess tibial plateau fractures. Image studies of 70 patients who sustained tibial plateau fractures were uploaded to a dedicated homepage. Every patient was linked to a folder which contained two radiographic projections (anteroposterior and lateral), three interactive videos of computed tomography (axial, sagittal, and coronal), and eight pictures depicting tridimensional reconstructions of the tibial plateau. Ten attending orthopaedic surgeons, who were blinded to the cases, were granted access to the homepage and assessed each set of images in two different rounds, separated to each other by an interval of 2 weeks. Each case was evaluated in three steps, where surgeons had access, respectively to radiographs, two-dimensional videos of computed tomography, and three-dimensional reconstruction images. After every step, surgeons were asked to present how would they classify the case using the Schatzker system and which surgical approaches would be appropriate. We evaluated the inter- and intraobserver reliability of the Schatzker classification using the Kappa concordance coefficient, as well as the impact of computed tomography in the decision making regarding the surgical approach for each case, by using the chi-square test and likelihood ratio. The interobserver concordance kappa coefficients after each assessment step were, respectively, 0.58, 0.62, and 0.64. For the intraobserver analysis, the coefficients were, respectively, 0.76, 0.75, and 0.78. Computed tomography changed the surgical approach selection for the types II, V, and VI of Schatzker ( p  < 0.01). The addition of

  5. The transesophageal echocardiography simulator based on computed tomography images.

    Science.gov (United States)

    Piórkowski, Adam; Kempny, Aleksander

    2013-02-01

    Simulators are a new tool in education in many fields, including medicine, where they greatly improve familiarity with medical procedures, reduce costs, and, importantly, cause no harm to patients. This is so in the case of transesophageal echocardiography (TEE), in which the use of a simulator facilitates spatial orientation and helps in case studies. The aim of the project described in this paper is to simulate an examination by TEE. This research makes use of available computed tomography data to simulate the corresponding echocardiographic view. This paper describes the essential characteristics that distinguish these two modalities and the key principles of the wave phenomena that should be considered in the simulation process, taking into account the conditions specific to the echocardiography. The construction of the CT2TEE (Web-based TEE simulator) is also presented. The considerations include ray-tracing and ray-casting techniques in the context of ultrasound beam and artifact simulation. An important aspect of the interaction with the user is raised.

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  7. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  8. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  9. A new Mumford-Shah total variation minimization based model for sparse-view x-ray computed tomography image reconstruction.

    Science.gov (United States)

    Chen, Bo; Bian, Zhaoying; Zhou, Xiaohui; Chen, Wensheng; Ma, Jianhua; Liang, Zhengrong

    2018-04-12

    Total variation (TV) minimization for the sparse-view x-ray computer tomography (CT) reconstruction has been widely explored to reduce radiation dose. However, due to the piecewise constant assumption for the TV model, the reconstructed images often suffer from over-smoothness on the image edges. To mitigate this drawback of TV minimization, we present a Mumford-Shah total variation (MSTV) minimization algorithm in this paper. The presented MSTV model is derived by integrating TV minimization and Mumford-Shah segmentation. Subsequently, a penalized weighted least-squares (PWLS) scheme with MSTV is developed for the sparse-view CT reconstruction. For simplicity, the proposed algorithm is named as 'PWLS-MSTV.' To evaluate the performance of the present PWLS-MSTV algorithm, both qualitative and quantitative studies were conducted by using a digital XCAT phantom and a physical phantom. Experimental results show that the present PWLS-MSTV algorithm has noticeable gains over the existing algorithms in terms of noise reduction, contrast-to-ratio measure and edge-preservation.

  10. Development of computational small animal models and their applications in preclinical imaging and therapy research.

    Science.gov (United States)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  11. Development of computational small animal models and their applications in preclinical imaging and therapy research

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Tianwu [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Geneva Neuroscience Center, Geneva University, Geneva CH-1205 (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen 9700 RB (Netherlands)

    2016-01-15

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  12. Development of computational small animal models and their applications in preclinical imaging and therapy research

    International Nuclear Information System (INIS)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future

  13. Positron emission tomography/computed tomography and radioimmunotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Capala, Jacek; Oehr, Peter

    2009-01-01

    of a number of diagnostic and therapeutic strategies. J591, a monoclonal antibody, which targets the extracellular domain of prostate-specific membrane antigen, shows promising results. HER2 receptors may also have a potential as target for PET/CT imaging and RIT of advanced prostate cancer. SUMMARY: PET......PURPOSE OF REVIEW: Traditional morphologically based imaging modalities are now being complemented by positron emission tomography (PET)/computed tomography (CT) in prostate cancer. Metastatic prostate cancer is an attractive target for radioimmunotherapy (RIT) as no effective therapies...... are available. This review highlights the most important achievements within the last year in PET/CT and RIT of prostate cancer. RECENT FINDINGS: Conflicting results exist on the use of choline for detection of malignant disease in the prostate gland. The role of PET/CT in N-staging remains to be elucidated...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  15. Data on analysis of coronary atherosclerosis on computed tomography and 18F-sodium fluoride positron emission tomography

    Directory of Open Access Journals (Sweden)

    Toshiro Kitagawa

    2017-08-01

    Full Text Available This article contains the data showing illustrative examples of plaque classification on coronary computed tomography angiography (CCTA and measurement of 18F-sodium fluoride (18F-NaF uptake in coronary atherosclerotic lesions on positron emission tomography (PET. We divided the lesions into one of three plaque types on CCTA (calcified plaque, non-calcified plaque, partially calcified plaque. Focal 18F-NaF uptake of each lesion was quantified using maximum tissue-to-background ratio. This article also provides a representative case with a non-calcified coronary plaque detected on CCTA and identified on 18F-NaF PET/non-contrast computed tomography based on a location of a vessel branch as a landmark. These complement the data reported by Kitagawa et al. (2017 [1].

  16. Quantitative image analysis of vertebral body architecture - improved diagnosis in osteoporosis based on high-resolution computed tomography

    International Nuclear Information System (INIS)

    Mundinger, A.; Wiesmeier, B.; Dinkel, E.; Helwig, A.; Beck, A.; Schulte Moenting, J.

    1993-01-01

    71 women, 64 post-menopausal, were examined by single-energy quantitative computed tomography (SEQCT) and by high-resolution computed tomography (HRCT) scans through the middle of lumbar vertebral bodies. Computer-assisted image analysis of the high-resolution images assessed trabecular morphometry of the vertebral spongiosa texture. Texture parameters differed in women with and without age-reduced bone density, and in the former group also in patients with and without vertebral fractures. Discriminating parameters were the total number, diameter and variance of trabecular and intertrabecular spaces as well as the trabecular surface (p < 0.05)). A texture index based on these statistically selected morphometric parameters identified a subgroup of patients suffering from fractures due to abnormal spongiosal architecture but with a bone mineral content not indicative for increased fracture risk. The combination of osteodensitometric and trabecular morphometry improves the diagnosis of osteoporosis and may contribute to the prediction of individual fracture risk. (author)

  17. A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

    International Nuclear Information System (INIS)

    Cai, C.; Rodet, T.; Mohammad-Djafari, A.; Legoupil, S.

    2013-01-01

    Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also

  18. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  19. The effects of simulating a realistic eye model on the eye dose of an adult male undergoing head computed tomography.

    Science.gov (United States)

    Akhlaghi, Parisa; Ebrahimi-Khankook, Atiyeh; Vejdani-Noghreiyan, Alireza

    2017-05-01

    In head computed tomography, radiation upon the eye lens (as an organ with high radiosensitivity) may cause lenticular opacity and cataracts. Therefore, quantitative dose assessment due to exposure of the eye lens and surrounding tissue is a matter of concern. For this purpose, an accurate eye model with realistic geometry and shape, in which different eye substructures are considered, is needed. To calculate the absorbed radiation dose of visual organs during head computed tomography scans, in this study, an existing sophisticated eye model was inserted at the related location in the head of the reference adult male phantom recommended by the International Commission on Radiological Protection (ICRP). Then absorbed doses and distributions of energy deposition in different parts of this eye model were calculated and compared with those based on a previous simple eye model. All calculations were done using the Monte Carlo code MCNP4C for tube voltages of 80, 100, 120 and 140 kVp. In spite of the similarity of total dose to the eye lens for both eye models, the dose delivered to the sensitive zone, which plays an important role in the induction of cataracts, was on average 3% higher for the sophisticated model as compared to the simple model. By increasing the tube voltage, differences between the total dose to the eye lens between the two phantoms decrease to 1%. Due to this level of agreement, use of the sophisticated eye model for patient dosimetry is not necessary. However, it still helps for an estimation of doses received by different eye substructures separately.

  20. Computed tomography of sacro-iliac joints

    International Nuclear Information System (INIS)

    Miquel, A.; Laredo, J.D.

    1995-01-01

    Actual technologies to explore sacro-iliac joints are conventional radiography, computed tomography , scintigraphy and nuclear magnetic resonance imaging. Standards films are sufficient, except in beginning sacro-iliac septic inflammations where the computed tomography is superior. Two problems are generally posed for the radiologist, to differentiate a septic arthritis from a rheumatic pathology An other problem in diagnosis is to make the difference between a degenerative arthropathy (which does not need a further investigation) and an infectious rheumatic pathology where more exploration is necessary. 28 refs., 3 tabs., 13 figs

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  3. Reproducibility in the assessment of acute pancreatitis with computed tomography

    International Nuclear Information System (INIS)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D'Ippolito, Giuseppe

    2007-01-01

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (κ). Results: Interobserver agreement was κ 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was κ = 0.796 and 0.732 for unenhanced morphological index; κ 0.725 and 0.802 for contrast- enhanced morphological index; κ = 0.674 and 0.849 for presence of pancreatic necrosis; κ = 0.606 and 0.770 for pancreatic necrosis extension; and κ = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  4. Diffuse abnormalities of the trachea: computed tomography findings

    International Nuclear Information System (INIS)

    Marchiori, Edson; Araujo Neto, Cesar de

    2008-01-01

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  5. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  6. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  7. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  8. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  9. Computed Tomography-Enhanced Anatomy Course Using Enterprise Visualization

    Science.gov (United States)

    May, Hila; Cohen, Haim; Medlej, Bahaa; Kornreich, Liora; Peled, Nathan; Hershkovitz, Israel

    2013-01-01

    Rapid changes in medical knowledge are forcing continuous adaptation of the basic science courses in medical schools. This article discusses a three-year experience developing a new Computed Tomography (CT)-based anatomy curriculum at the Sackler School of Medicine, Tel Aviv University, including describing the motivations and reasoning for the…

  10. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    Science.gov (United States)

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  11. Osteotomy simulation and soft tissue prediction using computer tomography scans

    International Nuclear Information System (INIS)

    Teschner, M.; Girod, S.; Girod, B.

    1999-01-01

    In this paper, a system is presented that can be used to simulate osteotomies of the skull and to estimate the resulting of tissue changes. Thus, the three-dimensional, photorealistic, postoperative appearance of a patient can be assessed. The system is based on a computer tomography scan and a photorealistic laser scan of the patient's face. In order to predict the postoperative appearance of a patient the soft tissue must follow the movement of the underlying bone. In this paper, a multi-layer soft tissue model is proposed that is based on springs. It incorporates features like skin turgor, gravity and sliding bone contact. The prediction of soft tissue changes due to bone realignments is computed using a very efficient and robust optimization method. The system can handle individual patient data sets and has been tested with several clinical cases. (author)

  12. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  13. Sacrococcygeal chordoma: increased 99mTc methylene diphosphonate uptake on single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppuswamy; Bhattacharya, Anish; Harisankar, Chidambaram Natarajan Balasubramaniam; Mittal, Bhagwant Rai; Goni, Vijay

    2012-01-01

    Chordoma is a malignant tumor arising from the remnants of the notochord, and is the most frequent primitive tumor of the sacrum. While most sacral tumors show increased concentration of bone-seeking radiopharmaceuticals, chordomas usually exhibit decreased uptake. The authors present an image of a sacrococcygeal chordoma with osteolysis and increased uptake of 99m Tc methylene diphosphonate on planar and single photon emission computed tomography/computed tomography bone scintigraphy. (author)

  14. Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts

    NARCIS (Netherlands)

    Waard, O. de; Rangel, F.A.; Fudalej, P.S.; Bronkhorst, E.M.; Kuijpers-Jagtman, A.M.; Breuning, K.H.

    2014-01-01

    INTRODUCTION: The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models

  15. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  16. Simulation of computed tomography dose based on voxel phantom

    Science.gov (United States)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  17. Technical Note. The Concept of a Computer System for Interpretation of Tight Rocks Using X-Ray Computed Tomography Results

    Directory of Open Access Journals (Sweden)

    Habrat Magdalena

    2017-03-01

    Full Text Available The article presents the concept of a computer system for interpreting unconventional oil and gas deposits with the use of X-ray computed tomography results. The functional principles of the solution proposed are presented in the article. The main goal is to design a product which is a complex and useful tool in a form of a specialist computer software for qualitative and quantitative interpretation of images obtained from X-ray computed tomography. It is devoted to the issues of prospecting and identification of unconventional hydrocarbon deposits. The article focuses on the idea of X-ray computed tomography use as a basis for the analysis of tight rocks, considering especially functional principles of the system, which will be developed by the authors. The functional principles include the issues of graphical visualization of rock structure, qualitative and quantitative interpretation of model for visualizing rock samples, interpretation and a description of the parameters within realizing the module of quantitative interpretation.

  18. Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography

    Science.gov (United States)

    Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2013-01-01

    OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418

  19. Computed tomography of head: impact of the use of automatic exposure control

    International Nuclear Information System (INIS)

    Souza, Giordana Salvi de Souza; Froner, Ana Paula Pastre; Silva, Ana Maria Marques da

    2017-01-01

    The use of dose reduction systems in computed tomography is particularly important for pediatric patients, who have a high radiosensitivity, since they are in the growing phase. The aim of this study was to evaluate the impact of Siemens AEC Care Dose system use on dose estimation in head computed tomography scans in pediatric patients. A retrospective study was conducted with 199 computed tomography head scans of pediatric patients, divided in different age groups, on a 16-channel Siemens Emotion scanner. It was possible to observe, for all age groups, that the use of AEC Care Dose system, not only reduced CTDI vol , but also the interquartile range, reducing the total dose in the investigated population. Concluding, AEC Care Dose system models the tube current according to the patient's dimensions, reducing individual and collective dose without affecting the diagnostic quality . (author)

  20. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  1. Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography

    Directory of Open Access Journals (Sweden)

    Yubin Liu

    2016-01-01

    Full Text Available We developed a homemade dual-modality imaging system that combines multispectral photoacoustic computed tomography and ultrasound computed tomography for reconstructing the structural and functional information of human finger joint systems. The fused multispectral photoacoustic-ultrasound computed tomography (MPAUCT system was examined by the phantom and in vivo experimental tests. The imaging results indicate that the hard tissues such as the bones and the soft tissues including the blood vessels, the tendon, the skins, and the subcutaneous tissues in the finger joints systems can be effectively recovered by using our multimodality MPAUCT system. The developed MPAUCT system is able to provide us with more comprehensive information of the human finger joints, which shows its potential for characterization and diagnosis of bone or joint diseases.

  2. Diagnosis of lumbar disc hernia with computed tomography

    International Nuclear Information System (INIS)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru

    1982-01-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed. (Ueda, J.)

  3. Research of scatter correction on industry computed tomography

    International Nuclear Information System (INIS)

    Sun Shaohua; Gao Wenhuan; Zhang Li; Chen Zhiqiang

    2002-01-01

    In the scanning process of industry computer tomography, scatter blurs the reconstructed image. The grey values of pixels in the reconstructed image are away from what is true and such effect need to be corrected. If the authors use the conventional method of deconvolution, many steps of iteration are needed and the computing time is not satisfactory. The author discusses a method combining Ordered Subsets Convex algorithm and scatter model to implement scatter correction and promising results are obtained in both speed and image quality

  4. Ultrasonic and computed tomography in radiotherapy planning - a comparison

    International Nuclear Information System (INIS)

    Schertel, L.

    1980-01-01

    The precondition of any radiotherapy is radiation planning. This must be done individually for every patient and must be applicable for any region of the body. Modern irradiation planning requires pictures of the body parts concerned; these can be made by means of the ultrasonic method and computed tomography. This comparative investigation leads to the result (see fig. 4 and 5) that computed tomographic body part pictures should be preferred to those made sonographically. The opinion of Huenig and Co. [8] that ultrasonic tomography will soon lose some of its importance within irradiation planning once computed tomography is introduced could be confirmed by the latest developments. The authors can confirm this also out of their own experience and agree with Winkel and Hermann [23] that computed tomography cannot be done without any more irradiation planning. (orig.) [de

  5. An Emotional Agent Model Based on Granular Computing

    Directory of Open Access Journals (Sweden)

    Jun Hu

    2012-01-01

    Full Text Available Affective computing has a very important significance for fulfilling intelligent information processing and harmonious communication between human being and computers. A new model for emotional agent is proposed in this paper to make agent have the ability of handling emotions, based on the granular computing theory and the traditional BDI agent model. Firstly, a new emotion knowledge base based on granular computing for emotion expression is presented in the model. Secondly, a new emotional reasoning algorithm based on granular computing is proposed. Thirdly, a new emotional agent model based on granular computing is presented. Finally, based on the model, an emotional agent for patient assistant in hospital is realized, experiment results show that it is efficient to handle simple emotions.

  6. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  7. Diagnosis of hoof diseases in horses using computed tomography

    International Nuclear Information System (INIS)

    Kovac, M.; Nowak, M.; Kaufels, N.; Tambur, Z.

    2002-01-01

    This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Bergische Tierklinik), Germany, of 39 horses with hoof diseases. The most frequently findings were the navicular syndrome (eight horses), laminitis (seven horses), keratnoma (six horses) and ossification of collateral cartilages in the distal phalanx (four horses). The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography

  8. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  9. Assessment of skull base involvement in nasopharyngeal carcinoma: comparisons of single-photon emission tomography with planar bone scintigraphy and X-ray computed tomography

    International Nuclear Information System (INIS)

    Lee Chianghsuan; Wang Peiwen; Chen Hueyong; Lui Chunchung; Su Chihying

    1995-01-01

    The diagnostic contribution of single-photon emission tomography (SPET) to the detection of bone lesions of the skull base was explored in 200 patients with nasopharyngeal carcinoma (NPC). Comparison of SPET with planar bone scintigraphy showed that SPET improved the contrast and better defined the lesions in 107 out of the 200 patients. Comparison of SPET with X-ray computed tomography (CT) showed that SPET did not miss the lesions detected by CT while CT missed 49% of the lesions detected by SPET. The only false-positive lesion with SPET was detected in the mastoid bone. SPET detected skull base lesions in all of the 35 patients with cranial nerve involvement, while CT missed eight and planar bone scintigraphy missed four. The findings suggest that SPET should be included in the routine check-up examinations of patients with NPC. (orig.)

  10. The accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing

    International Nuclear Information System (INIS)

    Kang, Ho Duk; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2007-01-01

    To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. Sprague-Dawely strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multiplanar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR images revealed similar reformation of the healing mount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imaging-based mythologies. MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing

  11. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  12. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  13. Role of single photon emission computed tomography/computed tomography in diagnostic iodine-131 scintigraphy before initial radioiodine ablation in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Agrawal, Kanhaiyalal; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2005-01-01

    The study was performed to evaluate the incremental value of single photon emission computed tomography/computed tomography (SPECT/CT) over planar radioiodine imaging before radioiodine ablation in the staging, management and stratification of risk of recurrence (ROR) in differentiated thyroid cancer (DTC) patients. Totally, 83 patients (21 male, 62 female) aged 17–75 (mean 39.9) years with DTC were included consecutively in this prospective study. They underwent postthyroidectomy planar and SPECT/CT scans after oral administration of 37–114 MBq iodine-131 (I-131). The scans were interpreted as positive, negative or suspicious for tracer uptake in the thyroid bed, cervical lymph nodes and sites outside the neck. In each case, the findings on planar images were recorded first, without knowledge of SPECT/CT findings. Operative and pathological findings were used for postsurgical tumor–node–metastasis staging. The tumor staging was reassessed after each of these two scans. Single photon emission computed tomography/computed tomography localized radioiodine uptake in the thyroid bed in 9/83 (10.8%) patients, neck nodes in 24/83 (28.9%) patients and distant metastases in 8/83 (9.6%) patients in addition to the planar study. Staging was changed in 8/83 (9.6%), ROR in 11/83 (13.2%) and management in 26/83 (31.3%) patients by the pretherapy SPECT/CT in comparison to planar imaging. SPECT/CT had incremental value in 32/83 patients (38.5%) over the planar scan. Single photon emission computed tomography/computed tomography is feasible during a diagnostic I-131 scan with a low amount of radiotracer. It improved the interpretation of pretherapy I-131 scintigraphy and changed the staging and subsequent patient management

  14. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  15. Clinical utility of dental cone-beam computed tomography: current perspectives

    OpenAIRE

    Jaju, Prashant P; Jaju, Sushma P

    2014-01-01

    Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology an...

  16. A PC-based discrete tomography imaging software system for assaying radioactive waste containers

    International Nuclear Information System (INIS)

    Palacios, J.C.; Longoria, L.C.; Santos, J.; Perry, R.T.

    2003-01-01

    A PC-based discrete tomography imaging software system for assaying radioactive waste containers for use in facilities in Mexico has been developed. The software system consists of three modules: (i) for reconstruction transmission tomography, (ii) for reconstruction emission tomography, and (iii) for simulation tomography. The Simulation Module is an interactive computer program that is used to create simulated databases for input to the Reconstruction Modules. These databases may be used in the absence of physical measurements to insure that the tomographic theoretical models are valid and that the coding accurately describes these models. Simulation may also be used to determine the detection limits of the reconstruction methodology. A description of the system, the theory, and a demonstration of the systems capabilities is provided in the paper. The hardware for this system is currently under development

  17. [Computed tomography semiotics of osteonecrosis and sequestration in chronic hematogenic osteomyelitis].

    Science.gov (United States)

    D'iachkova, G V; Mitina, Iu L

    2007-01-01

    Based on the data of computed tomography, radiography and densitometry in 39 patients the authors describe in detail the signs of osteonecrosis and sequestration of different localization and extension.

  18. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  19. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    OpenAIRE

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions wer...

  20. [Computer aided diagnosis model for lung tumor based on ensemble convolutional neural network].

    Science.gov (United States)

    Wang, Yuanyuan; Zhou, Tao; Lu, Huiling; Wu, Cuiying; Yang, Pengfei

    2017-08-01

    The convolutional neural network (CNN) could be used on computer-aided diagnosis of lung tumor with positron emission tomography (PET)/computed tomography (CT), which can provide accurate quantitative analysis to compensate for visual inertia and defects in gray-scale sensitivity, and help doctors diagnose accurately. Firstly, parameter migration method is used to build three CNNs (CT-CNN, PET-CNN, and PET/CT-CNN) for lung tumor recognition in CT, PET, and PET/CT image, respectively. Then, we aimed at CT-CNN to obtain the appropriate model parameters for CNN training through analysis the influence of model parameters such as epochs, batchsize and image scale on recognition rate and training time. Finally, three single CNNs are used to construct ensemble CNN, and then lung tumor PET/CT recognition was completed through relative majority vote method and the performance between ensemble CNN and single CNN was compared. The experiment results show that the ensemble CNN is better than single CNN on computer-aided diagnosis of lung tumor.

  1. Evolution of Computed Tomography Findings in Secondary Aortoenteric Fistula

    International Nuclear Information System (INIS)

    Bas, Ahmet; Simsek, Osman; Kandemirli, Sedat Giray; Rafiee, Babak; Gulsen, Fatih; Numan, Furuzan

    2015-01-01

    Aortoenteric fistula is a rare but significant clinical entity associated with high morbidity and mortality if remain untreated. Clinical presentation and imaging findings may be subtle and prompt diagnosis can be difficult. Herein, we present a patient who initially presented with abdominal pain and computed tomography showed an aortic aneurysm compressing duodenum without any air bubbles. One month later, the patient presented with gastrointestinal bleeding and computed tomography revealed air bubbles within aneurysm. With a diagnosis of aortoenteric fistula, endovascular aneurysm repair was carried out. This case uniquely presented the computed tomography findings in progression of an aneurysm to an aortoenteric fistula

  2. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  3. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    International Nuclear Information System (INIS)

    Macedo, Clarissa Aguiar de; Baena, Marcos Eduardo da Silva; Uezumi, Kiyomi Kato; Castro, Claudio Campi de; Lucarelli, Claudio Luiz; Cerri, Giovanni Guido

    2008-01-01

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  4. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  5. Computed tomography in intracranial malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, S; Odake, G; Fujimoto, M; Yamaki, T; Mizukawa, N [Kyoto Prefectural Univ. of Medicine (Japan)

    1978-09-01

    Malignant lymphoma of the central nervous system has been found more and more often in recent years, partly because of the increased use of radiation and such drugs as steroids and antibiotics. However, the definite diagnosis of this disease is difficult until histological verification has been done by operation or autopsy. Since the revolutionary development of computed tomography, however, several reports have been presented, on the computed tomography of malignant lymphoma of the thorax and abdomen. Nevertheless, only a few cases of intracranial malignant lymphoma have been reported. The purpose of this paper, using four patients, is to emphasize the value of computed tomography in the diagnosis of intracranial malignant lymphoma. The characteristic CT findings of intracranial malignant lymphoma may be summarized follows: (1) the tumors are demonstrated to be well-defined, nodular-shaped, and homogenous isodensity - or slightly high-density - lesions in plain scans, and the tumors homogenously increase in density upon contrast enhancement; (2) the disease always has multifocal intracranial lesions, which are shown simultaneously or one after another, and (3) perifocal edema is prominent around the tumors in the cerebral hemisphere.

  6. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  7. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  8. Performance dependence of hybrid x-ray computed tomography/fluorescence molecular tomography on the optical forward problem.

    Science.gov (United States)

    Hyde, Damon; Schulz, Ralf; Brooks, Dana; Miller, Eric; Ntziachristos, Vasilis

    2009-04-01

    Hybrid imaging systems combining x-ray computed tomography (CT) and fluorescence tomography can improve fluorescence imaging performance by incorporating anatomical x-ray CT information into the optical inversion problem. While the use of image priors has been investigated in the past, little is known about the optimal use of forward photon propagation models in hybrid optical systems. In this paper, we explore the impact on reconstruction accuracy of the use of propagation models of varying complexity, specifically in the context of these hybrid imaging systems where significant structural information is known a priori. Our results demonstrate that the use of generically known parameters provides near optimal performance, even when parameter mismatch remains.

  9. Computed tomography in epidural abscess, subdural empyema, meningitis, and brain abscess

    International Nuclear Information System (INIS)

    Schadel, A.; Boettcher, H.D.; Haverkamp, U.; Wagner, W.; Schmilowski, G.M.; Muenster Univ.

    1983-01-01

    Computerised tomography cannot be of great help in diagnosing meningitis. Examination of the cerebrospinal fluid remains essential. After the inflammation of the meninges has progressed to some stage of encephalitis, the formation of an abscess can be located via computed tomography. It is characterised by the ring-type abscess capsule. Computed tomography for diagnostic purposes is superior to cerebral scanning, which demonstrates enhanced activity, but does not show the formation of a membrane, so essential for differential diagnosis. Furthermore, computed tomography shows the adjacent anatomical structures and answers the questions of displacements and threatening invasion of the ventricle system. Epidural and subdural abscesses can also be located by computed tomography. Therapy can begin directly after computerised tomography, whereas in scintigraphy only a non-specific enhanced activity is present, which often does not allow differentiation between epidural and subdural location. (orig.) [de

  10. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  11. Efficacy of navigation in skull base surgery using composite computer graphics of magnetic resonance and computed tomography images

    International Nuclear Information System (INIS)

    Hayashi, Nakamasa; Kurimoto, Masanori; Hirashima, Yutaka; Ikeda, Hiroaki; Shibata, Takashi; Tomita, Takahiro; Endo, Shunro

    2001-01-01

    The efficacy of a neurosurgical navigation system using three-dimensional composite computer graphics (CGs) of magnetic resonance (MR) and computed tomography (CT) images was evaluated in skull base surgery. Three-point transformation was used for integration of MR and CT images. MR and CT image data were obtained with three skin markers placed on the patient's scalp. Volume-rendering manipulations of the data produced three-dimensional CGs of the scalp, brain, and lesions from the MR images, and the scalp and skull from the CT. Composite CGs of the scalp, skull, brain, and lesion were created by registering the three markers on the three-dimensional rendered scalp images obtained from MR imaging and CT in the system. This system was used for 14 patients with skull base lesions. Three-point transformation using three-dimensional CGs was easily performed for multimodal registration. Simulation of surgical procedures on composite CGs aided in comprehension of the skull base anatomy and selection of the optimal approaches. Intraoperative navigation aided in determination of actual spatial position in the skull base and the optimal trajectory to the tumor during surgical procedures. (author)

  12. GEANT4 simulations for Proton computed tomography applications

    International Nuclear Information System (INIS)

    Yevseyeva, Olga; Assis, Joaquim T. de; Evseev, Ivan; Schelin, Hugo R.; Shtejer Diaz, Katherin; Lopes, Ricardo T.

    2011-01-01

    Proton radiation therapy is a highly precise form of cancer treatment. In existing proton treatment centers, dose calculations are performed based on X-ray computed tomography (CT). Alternatively, one could image the tumor directly with proton CT (pCT). Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the general case on the accuracy of results obtained for the proton interaction with thick absorbers. GEANT4 simulations of proton energy spectra after passing thick absorbers do not agree well with existing experimental data, as showed previously. The spectra simulated for the Bethe-Bloch domain showed an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 version 8.2 during our simulations for pCT. This work describes in more details the simulations of the proton passage through gold absorbers with varied thickness. The simulations were done by modifying only the geometry in the Hadron therapy Example, and for all available choices of the Electromagnetic Physics Models. As the most probable reasons for these effects is some specific feature in the code or some specific implicit parameters in the GEANT4 manual, we continued our study with version 9.2 of the code. Some improvements in comparison with our previous results were obtained. The simulations were performed considering further applications for pCT development. The authors want to thank CNPq, CAPES and 'Fundacao Araucaria' for financial support of this work. (Author)

  13. Computed tomography of craniomandibular osteopathy in a dog

    International Nuclear Information System (INIS)

    Hudson, J.A.; Montgomery, R.D.; Hathcock, J.T.; Jarboe, J.M.

    1994-01-01

    This report describes the use of computed tomography (CT) to evaluate the tympanic bullae and angular processes of the mandible in a West Highland White Terrier with craniomandibular osteopathy. The patient presented initially for swelling of the right forelimb. The report illustrates the use of computed tomography for evaluation of craniomandibular osteopathy, initial presentation with long-bone pathology, and remarkable resolution of osseous changes

  14. Comparative Evaluation of a Four-Implant-Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design.

    Science.gov (United States)

    Lee, Ki-Sun; Shin, Sang-Wan; Lee, Sang-Pyo; Kim, Jong-Eun; Kim, Jee-Hwan; Lee, Jeong-Yol

    The purpose of this pilot study was to evaluate and compare polyetherketoneketone (PEKK) with different framework materials for implant-supported prostheses by means of a three-dimensional finite element analysis (3D-FEA) based on cone beam computed tomography (CBCT) and computer-aided design (CAD) data. A geometric model that consisted of four maxillary implants supporting a prosthesis framework was constructed from CBCT and CAD data of a treated patient. Three different materials (zirconia, titanium, and PEKK) were selected, and their material properties were simulated using FEA software in the generated geometric model. In the PEKK framework (ie, low elastic modulus) group, the stress transferred to the implant and simulated adjacent tissue was reduced when compressive stress was dominant, but increased when tensile stress was dominant. This study suggests that the shock-absorbing effects of a resilient implant-supported framework are limited in some areas and that rigid framework material shows a favorable stress distribution and safety of overall components of the prosthesis.

  15. Computational model for dosimetric purposes in dental procedures

    International Nuclear Information System (INIS)

    Kawamoto, Renato H.; Campos, Tarcisio R.

    2013-01-01

    This study aims to develop a computational model for dosimetric purposes the oral region, based on computational tools SISCODES and MCNP-5, to predict deterministic effects and minimize stochastic effects caused by ionizing radiation by radiodiagnosis. Based on a set of digital information provided by computed tomography, three-dimensional voxel model was created, and its tissues represented. The model was exported to the MCNP code. In association with SICODES, we used the Monte Carlo N-Particle Transport Code (MCNP-5) method to play the corresponding interaction of nuclear particles with human tissues statistical process. The study will serve as a source of data for dosimetric studies in the oral region, providing deterministic effect and minimize the stochastic effect of ionizing radiation

  16. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2014-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... examined the content, data quality, and research potential of the WDHR-CCTR. METHODS: We retrieved 2008-2012 data to examine the 1) content; 2) completeness of procedure registration using the Danish National Patient Registry as reference; 3) completeness of variable registration comparing observed vs...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  18. Pathomorphism of spiral tibial fractures in computed tomography imaging.

    Science.gov (United States)

    Guzik, Grzegorz

    2011-01-01

    Spiral fractures of the tibia are virtually homogeneous with regard to their pathomorphism. The differences that are seen concern the level of fracture of the fibula, and, to a lesser extent, the level of fracture of the tibia, the length of fracture cleft, and limb shortening following the trauma. While conventional radiographs provide sufficient information about the pathomorphism of fractures, computed tomography can be useful in demonstrating the spatial arrangement of bone fragments and topography of soft tissues surrounding the fracture site. Multiple cross-sectional computed tomography views of spiral fractures of the tibia show the details of the alignment of bone chips at the fracture site, axis of the tibial fracture cleft, and topography of soft tissues that are not visible on standard radiographs. A model of a spiral tibial fracture reveals periosteal stretching with increasing spiral and longitudinal displacement. The cleft in tibial fractures has a spiral shape and its line is invariable. Every spiral fracture of both crural bones results in extensive damage to the periosteum and may damage bellies of the long flexor muscle of toes, flexor hallucis longus as well as the posterior tibial muscle. Computed tomography images of spiral fractures of the tibia show details of damage that are otherwise invisible on standard radiographs. Moreover, CT images provide useful information about the spatial location of the bone chips as well as possible threats to soft tissues that surround the fracture site. Every spiral fracture of the tibia is associated with disruption of the periosteum. 1. Computed tomography images of spiral fractures of the tibia show details of damage otherwise invisible on standard radiographs, 2. The sharp end of the distal tibial chip can damage the tibialis posterior muscle, long flexor muscles of the toes and the flexor hallucis longus, 3. Every spiral fracture of the tibia is associated with disruption of the periosteum.

  19. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  20. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  1. Bosniak classification of renal cystic lesions according to multidetector computed tomography findings

    International Nuclear Information System (INIS)

    Miranda, Christiana Maia Nobre Rocha de; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Rocha, Milzi Sarmento da; Maranhao, Carol Pontes de Miranda; Santos, Carla Jotta Justo dos

    2014-01-01

    Renal cystic lesions are usually diagnosed in the radiologists' practice and therefore their characterization is crucial to determine the clinical approach to be adopted and prognosis. The Bosniak classification based on computed tomography findings has allowed for standardization and categorization of lesions in increasing order of malignancy (I, II, IIF, III and IV) in a simple and accurate way. The present iconographic essay developed with multidetector computed tomography images of selected cases from the archives of the authors' institution, is aimed at describing imaging findings that can help in the diagnosis of renal cysts. (author)

  2. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  3. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  5. Computed tomography of the head in neurological examination of children

    International Nuclear Information System (INIS)

    Baeckman, E.; Egg-Olofsson, O.; Raadberg, C.

    1980-01-01

    A total of 247 children from the departments of pediatrics and neurosurgery were examined with computed tomography of the head during a two year period in 1977-78. Pathological changes were demonstrated in 79 per cent. Supplementary neuro-radiological examination - angiography and encephalography - was necessary in 17 per cent. Computed tomography together with the clinical assessment frequently suffices for final diagnosis. Computed tomography greatly reduces the need for previously used neurological examinations including skull radiography. Complications may ensure because of over-sensitivity to intravenously administered contrast medium in connection with anesthesia, and the radiation dose particularly to the crystalline lens of the eye must be taken into account. Computed tomography should therefore be used only on strict indications after careful scrutiny of the case history and the status. (author)

  6. Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy

    NARCIS (Netherlands)

    Parodi, Katia; Paganetti, Harald; Shih, Helen A; Michaud, Susan; Loeffler, Jay S; DeLaney, Thomas F; Liebsch, Norbert J; Munzenrider, John E; Fischman, Alan J; Knopf, Antje; Bortfeld, Thomas

    2007-01-01

    PURPOSE: To investigate the feasibility and value of positron emission tomography and computed tomography (PET/CT) for treatment verification after proton radiotherapy. METHODS AND MATERIALS: This study included 9 patients with tumors in the cranial base, spine, orbit, and eye. Total doses of 1.8-3

  7. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  8. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

    Science.gov (United States)

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin

    2015-03-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (pimplants using micro-CT analysis using a region-based segmentation method.

  9. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  10. Effects of computer tomography on diagnosis of neurological and neurosurgical diseases

    International Nuclear Information System (INIS)

    Katzner, E.

    1981-01-01

    Computer tomography is presently the primary procedure for correct diagnosis of many neurological and neurosurgical diseases. Other expensive and riskier diagnostic methods have become superfluous. Selective and clearly indicated application of the undoubtedly expensive computer tomography ultimately spares unnecessary costs for hospitalization and less conclusive examination methods. Wheras the indications in the craniocerebral region can now be considered confirmed, spinal computer tomography is still in the development stage. With certain indications, e.g. in prolapsed lumbar intervertebral disk, a similar performance to that of CT can be obtained with myelography, so that the latter method is likely to be superceded by computer tomography. (orig.) [de

  11. Post-mortem computed tomography angiography utilizing barium sulfate to identify microvascular structures : a preliminary phantom model and case study

    NARCIS (Netherlands)

    Haakma, Wieke; Rohde, Marianne; Kuster, Lidy; Uhrenholt, Lars; Pedersen, Michael; Boel, Lene Warner Thorup

    2016-01-01

    We investigated the use of computer tomography angiography (CTA) to visualize microvascular structures in a vessel-mimicking phantom and post-mortem (PM) bodies. A contrast agent was used based on 22% barium sulfate, 20% polyethylene glycol and 58% distilled water. A vessel-mimicking phantom

  12. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  13. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias; Furtwaengler, Alex

    2003-01-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST ( 5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  14. Optical coherence tomography and computer-aided diagnosis of a murine model of chronic kidney disease

    Science.gov (United States)

    Wang, Bohan; Wang, Hsing-Wen; Guo, Hengchang; Anderson, Erik; Tang, Qinggong; Wu, Tongtong; Falola, Reuben; Smith, Tikina; Andrews, Peter M.; Chen, Yu

    2017-12-01

    Chronic kidney disease (CKD) is characterized by a progressive loss of renal function over time. Histopathological analysis of the condition of glomeruli and the proximal convolutional tubules over time can provide valuable insights into the progression of CKD. Optical coherence tomography (OCT) is a technology that can analyze the microscopic structures of a kidney in a nondestructive manner. Recently, we have shown that OCT can provide real-time imaging of kidney microstructures in vivo without administering exogenous contrast agents. A murine model of CKD induced by intravenous Adriamycin (ADR) injection is evaluated by OCT. OCT images of the rat kidneys have been captured every week up to eight weeks. Tubular diameter and hypertrophic tubule population of the kidneys at multiple time points after ADR injection have been evaluated through a fully automated computer-vision system. Results revealed that mean tubular diameter and hypertrophic tubule population increase with time in post-ADR injection period. The results suggest that OCT images of the kidney contain abundant information about kidney histopathology. Fully automated computer-aided diagnosis based on OCT has the potential for clinical evaluation of CKD conditions.

  15. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  16. An Effective Approach of Teeth Segmentation within the 3D Cone Beam Computed Tomography Image Based on Deformable Surface Model

    Directory of Open Access Journals (Sweden)

    Xutang Zhang

    2016-01-01

    Full Text Available In order to extract the pixels of teeth from 3D Cone Beam Computed Tomography (CBCT image, in this paper, a novel 3D segmentation approach based on deformable surface mode is developed for 3D tooth model reconstruction. Different forces are formulated to handle the segmentation problem by using different strategies. First, the proposed method estimates the deformation force of vertex model by simulating the deformation process of a bubble under the action of internal pressure and external force field. To handle the blurry boundary, a “braking force” is proposed deriving from the 3D gradient information calculated by transforming the Sobel operator into three-dimension representation. In addition, a “border reinforcement” strategy is developed for handling the cases with complicate structures. Moreover, the proposed method combines affine cell image decomposition (ACID grid reparameterization technique to handle the unstable changes of topological structure and deformability during the deformation process. The proposed method was performed on 510 CBCT images. To validate the performance, the results were compared with those of two other well-studied methods. Experimental results show that the proposed approach had a good performance in handling the cases with complicate structures and blurry boundaries well, is effective to converge, and can successfully achieve the reconstruction task of various types of teeth in oral cavity.

  17. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  18. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  19. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  20. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  2. Utility of screening computed tomography of chest, abdomen and pelvis in patients after heart transplantation

    International Nuclear Information System (INIS)

    Dasari, Tarun W.; Pavlovic-Surjancev, Biljana; Dusek, Linda; Patel, Nilamkumar; Heroux, Alain L.

    2011-01-01

    Introduction: Malignancy is a late cause of mortality in heart transplant recipients. It is unknown if screening computed tomography scan would lead to early detection of such malignancies or serious vascular anomalies post heart transplantation. Methods: This is a single center observational study of patients undergoing surveillance computed tomography of chest, abdomen and pelvis atleast 5 years after transplantation. Abnormal findings, included pulmonary nodules, lymphadenopathy and intra-thoracic and intra-abdominal masses and vascular anomalies such as abdominal aortic aneurysm. The clinical follow up of each of these major abnormal findings is summarized. Results: A total of 63 patients underwent computed tomography scan of chest, abdomen and pelvis at least 5 years after transplantation. Of these, 54 (86%) were male and 9 (14%) were female. Mean age was 52 ± 9.2 years. Computed tomography revealed 1 lung cancer (squamous cell) only. Non specific pulmonary nodules were seen in 6 patients (9.5%). The most common incidental finding was abdominal aortic aneurysms (N = 6 (9.5%)), which necessitated follow up computed tomography (N = 5) or surgery (N = 1). Mean time to detection of abdominal aortic aneurysms from transplantation was 14.6 ± 4.2 years. Mean age at the time of detection of abdominal aortic aneurysms was 74.5 ± 3.2 years. Conclusion: Screening computed tomography scan in patients 5 years from transplantation revealed only one malignancy but lead to increased detection of abdominal aortic aneurysms. Thus the utility is low in terms of detection of malignancy. Based on this study we do not recommend routine computed tomography post heart transplantation.

  3. Effect of Novel Amplitude/Phase Binning Algorithm on Commercial Four-Dimensional Computed Tomography Quality

    International Nuclear Information System (INIS)

    Olsen, Jeffrey R.; Lu Wei; Hubenschmidt, James P.; Nystrom, Michelle M.; Klahr, Paul; Bradley, Jeffrey D.; Low, Daniel A.; Parikh, Parag J.

    2008-01-01

    Purpose: Respiratory motion is a significant source of anatomic uncertainty in radiotherapy planning and can result in errors of portal size and the subsequent radiation dose. Although four-dimensional computed tomography allows for more accurate analysis of the respiratory cycle, breathing irregularities during data acquisition can cause considerable image distortions. The aim of this study was to examine the effect of respiratory irregularities on four-dimensional computed tomography, and to evaluate a novel image reconstruction algorithm using percentile-based tagging of the respiratory cycle. Methods and Materials: Respiratory-correlated helical computed tomography scans were acquired for 11 consecutive patients. The inspiration and expiration data sets were reconstructed using the default phase-based method, as well as a novel respiration percentile-based method with patient-specific metrics to define the ranges of the reconstruction. The image output was analyzed in a blinded fashion for the phase- and percentile-based reconstructions to determine the prevalence and severity of the image artifacts. Results: The percentile-based algorithm resulted in a significant reduction in artifact severity compared with the phase-based algorithm, although the overall artifact prevalence did not differ between the two algorithms. The magnitude of differences in respiratory tag placement between the phase- and percentile-based algorithms correlated with the presence of image artifacts. Conclusion: The results of our study have indicated that our novel four-dimensional computed tomography reconstruction method could be useful in detecting clinically relevant image distortions that might otherwise go unnoticed and to reduce the image distortion associated with some respiratory irregularities. Additional work is necessary to assess the clinical impact on areas of possible irregular breathing

  4. Radiation dose in cone-beam computed tomography: myth or reality

    International Nuclear Information System (INIS)

    Madi, Medhini

    2013-01-01

    In the growing inventory of clinical computed tomography technologies, cone-beam X-ray computed tomography is a relatively recent instalment. It is an advancement in computed tomography imaging which is designed to provide relatively low-dose high-spatial-resolution visualization of high contrast structures in the head and neck and other anatomic areas. Comparatively low dosing requirements and relatively compact design has led to intense interest in surgical planning and intra-operative cone-beam computed tomography applications, particularly in head and neck, and also in spinal, thoracic, abdominal and orthopaedic procedures. The use of this emerging imaging technology, which has potential applications for imaging of high-contrast structures in the head and neck as well as dentomaxillofacial regions, has been the subject of criticism as well as acclaim. This paper envisages to discuss the state-of-the-art of the technique. (author)

  5. Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations

    Energy Technology Data Exchange (ETDEWEB)

    Neroladaki, Angeliki; Botsikas, Diomidis; Boudabbous, Sana; Becker, Christoph D.; Montet, Xavier [Geneva University Hospital, Department of Radiology, Geneva 4 (Switzerland)

    2013-02-15

    The purpose of this study was to assess the diagnostic image quality of ultra-low-dose chest computed tomography (ULD-CT) obtained with a radiation dose comparable to chest radiography and reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard dose diagnostic CT (SDD-CT) or low-dose diagnostic CT (LDD-CT) reconstructed with FBP alone. Unenhanced chest CT images of 42 patients acquired with ULD-CT were compared with images obtained with SDD-CT or LDD-CT in the same examination. Noise measurements and image quality, based on conspicuity of chest lesions on all CT data sets were assessed on a five-point scale. The radiation dose of ULD-CT was 0.16 {+-} 0.006 mSv compared with 11.2 {+-} 2.7 mSv for SDD-CT (P < 0.0001) and 2.7 {+-} 0.9 mSv for LDD-CT. Image quality of ULD-CT increased significantly when using MBIR compared with FBP or ASIR (P < 0.001). ULD-CT reconstructed with MBIR enabled to detect as many non-calcified pulmonary nodules as seen on SDD-CT or LDD-CT. However, image quality of ULD-CT was clearly inferior for characterisation of ground glass opacities or emphysema. Model-based iterative reconstruction allows detection of pulmonary nodules with ULD-CT with radiation exposure in the range of a posterior to anterior (PA) and lateral chest X-ray. (orig.)

  6. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions

    NARCIS (Netherlands)

    Wiranto, Matthew G.; Engelbrecht, W. Petrie; Nolthenius, Heleen E. Tutein; van der Meer, W. Joerd; Ren, Yijin

    INTRODUCTION: Digital 3-dimensional models are widely used for orthodontic diagnosis. The aim of this study was to assess the validity, reliability, and reproducibility of digital models obtained from the Lava Chairside Oral scanner (3M ESPE, Seefeld, Germany) and cone-beam computed tomography scans

  7. Computer tomography in the diagnosis of liver diseases

    International Nuclear Information System (INIS)

    Petkov, D.; Zhelyazkov, S.; Nedelkov, G.

    1983-01-01

    The modern achievements in the clinical study and diagnosis of liver diseases has definitely been associated with the application of whole body computer tomography (CT) in the practice. The diagnostic possibilities of the method come from high contrast and spacial disjunctive capabilities. Visualization of local lesions is associated with their size and the differences in their densitometric compactness from that of the normal parenchyma. The advantages of computer tomography in the diagnosis of liver diseases is discussed. They are associated with the possibilities for densitometric analysis of the pathologic changes, which opens a way for a probable qualitative diagnosis. Diffuse processes in the liver are relative indication for performing computer tomography. Examination under conditions of contrast amplification is indicated in cases when the nature of the lesion has to be specified and a ''negative'' result does not concur with the clinical manifestations. (authors)

  8. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    Sawicka, B.

    1992-01-01

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  9. Computed Tomography Technology: Development and Applications for Defence

    International Nuclear Information System (INIS)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-01-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT and E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  10. X-Ray Computed Tomography of Tranquility Base Moon Rock

    Science.gov (United States)

    Jones, Justin S.; Garvin, Jim; Viens, Mike; Kent, Ryan; Munoz, Bruno

    2016-01-01

    X-ray Computed Tomography (CT) was used for the first time on the Apollo 11 Lunar Sample number 10057.30, which had been previously maintained by the White House, then transferred back to NASA under the care of Goddard Space Flight Center. Results from this analysis show detailed images of the internal structure of the moon rock, including vesicles (pores), crystal needles, and crystal bundles. These crystals, possibly the common mineral ilmenite, are found in abundance and with random orientation. Future work, in particular a greater understanding of these crystals and their formation, may lead to a more in-depth understanding of the lunar surface evolution and mineral content.

  11. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  12. Development of a proton Computed Tomography Detector System

    Energy Technology Data Exchange (ETDEWEB)

    Naimuddin, Md. [Delhi U.; Coutrakon, G. [Northern Illinois U.; Blazey, G. [Northern Illinois U.; Boi, S. [Northern Illinois U.; Dyshkant, A. [Northern Illinois U.; Erdelyi, B. [Northern Illinois U.; Hedin, D. [Northern Illinois U.; Johnson, E. [Northern Illinois U.; Krider, J. [Northern Illinois U.; Rukalin, V. [Northern Illinois U.; Uzunyan, S. A. [Northern Illinois U.; Zutshi, V. [Northern Illinois U.; Fordt, R. [Fermilab; Sellberg, G. [Fermilab; Rauch, J. E. [Fermilab; Roman, M. [Fermilab; Rubinov, P. [Fermilab; Wilson, P. [Fermilab

    2016-02-04

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  13. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  14. A bent Laue-Laue monochromator for a synchrotron-based computed tomography system

    CERN Document Server

    Ren, B; Chapman, L D; Ivanov, I; Wu, X Y; Zhong, Z; Huang, X

    1999-01-01

    We designed and tested a two-crystal bent Laue-Laue monochromator for wide, fan-shaped synchrotron X-ray beams for the program multiple energy computed tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT employs monochromatic X-ray beams from the NSLS's X17B superconducting wiggler beamline for computed tomography (CT) with an improved image quality. MECT uses a fixed horizontal fan-shaped beam with the subject's apparatus rotating around a vertical axis. The new monochromator uses two Czochralski-grown Si crystals, 0.7 and 1.4 mm thick, respectively, and with thick ribs on their upper and lower ends. The crystals are bent cylindrically, with the axis of the cylinder parallel to the fan beam, using 4-rod benders with two fixed rods and two movable ones. The bent-crystal feature of the monochromator resolved the difficulties we had had with the flat Laue-Laue design previously used in MECT, which included (a) inadequate beam intensity, (b) excessive fluctuations in beam intensity, and (c) i...

  15. Assessement of computer tomography usefulness in the diagnosis of arterial hypertension in adrenal diseases

    International Nuclear Information System (INIS)

    Pacho, R.; Feltynowski, T.

    1981-01-01

    The results of computer tomoqraphy done in 105 patients with hypertension due to various adrenal diseases diagnosed clinically and after laboratory investigations were analysed. The investigation was done with a Delta-Scan Ohio-Nuclear-Siemens unit. In 35 cases the findings of computer tomography were confirmed surgically: 12 cases of adrenal adenoma the smallest one had 5 mm in diameter due to primary hyperaidosteronism, 3 cases of adenoma, 2 carcinomas and 1 case of adrenocortical hypertrophy in Cushing's sydrome as well as 15 phaeochromocytomas inclunding two situated outside the adrenals. A case of ganglioneuroma in a 3-year-old child was also diagnosed correctly. The characteristic features of pathological adrenal changes observed during computer tomography in these patients were described. The high effectiveness of the diagnoses based on the results of laboratory investigations and computer tomography is stressed. (author)

  16. Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Eun; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Jung, Woo Hyun; Choi, Byeong Don [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2016-12-15

    The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54⁓2.33, 5.16⁓8.06, 9.03⁓20.11 ml in MIP, respectively, 0.00⁓1.48, 0.00⁓8.47, 1.42⁓24.85 ml in MinIP, respectively and 0.00⁓1.17, 0.00⁓2.19, 0.04⁓3.35 ml in AVG, respectively. After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  17. Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours

    International Nuclear Information System (INIS)

    Amthauer, H.; Denecke, T.; Ruf, J.; Gutberlet, M.; Felix, R.; Lemke, A.J.; Rohlfing, T.; Boehmig, M.; Ploeckinger, U.

    2005-01-01

    The objective was the evaluation of single photon emission computed tomography (SPECT) with integrated low dose computed tomography (CT) in comparison with a retrospective fusion of SPECT and high-resolution CT and a side-by-side analysis for lesion localisation in patients with neuroendocrine tumours. Twenty-seven patients were examined by multidetector CT. Additionally, as part of somatostatin receptor scintigraphy (SRS), an integrated SPECT-CT was performed. SPECT and CT data were fused using software with a registration algorithm based on normalised mutual information. The reliability of the topographic assignment of lesions in SPECT-CT, retrospective fusion and side-by-side analysis was evaluated by two blinded readers. Two patients were not enrolled in the final analysis because of misregistrations in the retrospective fusion. Eighty-seven foci were included in the analysis. For the anatomical assignment of foci, SPECT-CT and retrospective fusion revealed overall accuracies of 91 and 94% (side-by-side analysis 86%). The correct identification of foci as lymph node manifestations (n=25) was more accurate by retrospective fusion (88%) than from SPECT-CT images (76%) or by side-by-side analysis (60%). Both modalities of image fusion appear to be well suited for the localisation of SRS foci and are superior to side-by-side analysis of non-fused images especially concerning lymph node manifestations. (orig.)

  18. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  19. Rapid data processing for ultrafast X-ray computed tomography using scalable and modular CUDA based pipelines

    Science.gov (United States)

    Frust, Tobias; Wagner, Michael; Stephan, Jan; Juckeland, Guido; Bieberle, André

    2017-10-01

    Ultrafast X-ray tomography is an advanced imaging technique for the study of dynamic processes basing on the principles of electron beam scanning. A typical application case for this technique is e.g. the study of multiphase flows, that is, flows of mixtures of substances such as gas-liquidflows in pipelines or chemical reactors. At Helmholtz-Zentrum Dresden-Rossendorf (HZDR) a number of such tomography scanners are operated. Currently, there are two main points limiting their application in some fields. First, after each CT scan sequence the data of the radiation detector must be downloaded from the scanner to a data processing machine. Second, the current data processing is comparably time-consuming compared to the CT scan sequence interval. To enable online observations or use this technique to control actuators in real-time, a modular and scalable data processing tool has been developed, consisting of user-definable stages working independently together in a so called data processing pipeline, that keeps up with the CT scanner's maximal frame rate of up to 8 kHz. The newly developed data processing stages are freely programmable and combinable. In order to achieve the highest processing performance all relevant data processing steps, which are required for a standard slice image reconstruction, were individually implemented in separate stages using Graphics Processing Units (GPUs) and NVIDIA's CUDA programming language. Data processing performance tests on different high-end GPUs (Tesla K20c, GeForce GTX 1080, Tesla P100) showed excellent performance. Program Files doi:http://dx.doi.org/10.17632/65sx747rvm.1 Licensing provisions: LGPLv3 Programming language: C++/CUDA Supplementary material: Test data set, used for the performance analysis. Nature of problem: Ultrafast computed tomography is performed with a scan rate of up to 8 kHz. To obtain cross-sectional images from projection data computer-based image reconstruction algorithms must be applied. The

  20. Computational adaptive optics for broadband interferometric tomography of tissues and cells

    Science.gov (United States)

    Adie, Steven G.; Mulligan, Jeffrey A.

    2016-03-01

    Adaptive optics (AO) can shape aberrated optical wavefronts to physically restore the constructive interference needed for high-resolution imaging. With access to the complex optical field, however, many functions of optical hardware can be achieved computationally, including focusing and the compensation of optical aberrations to restore the constructive interference required for diffraction-limited imaging performance. Holography, which employs interferometric detection of the complex optical field, was developed based on this connection between hardware and computational image formation, although this link has only recently been exploited for 3D tomographic imaging in scattering biological tissues. This talk will present the underlying imaging science behind computational image formation with optical coherence tomography (OCT) -- a beam-scanned version of broadband digital holography. Analogous to hardware AO (HAO), we demonstrate computational adaptive optics (CAO) and optimization of the computed pupil correction in 'sensorless mode' (Zernike polynomial corrections with feedback from image metrics) or with the use of 'guide-stars' in the sample. We discuss the concept of an 'isotomic volume' as the volumetric extension of the 'isoplanatic patch' introduced in astronomical AO. Recent CAO results and ongoing work is highlighted to point to the potential biomedical impact of computed broadband interferometric tomography. We also discuss the advantages and disadvantages of HAO vs. CAO for the effective shaping of optical wavefronts, and highlight opportunities for hybrid approaches that synergistically combine the unique advantages of hardware and computational methods for rapid volumetric tomography with cellular resolution.

  1. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  2. Functional computed tomography imaging of tumor-induced angiogenesis. Preliminary results of new tracer kinetic modeling using a computer discretization approach

    International Nuclear Information System (INIS)

    Kaneoya, Katsuhiko; Ueda, Takuya; Suito, Hiroshi

    2008-01-01

    The aim of this study was to establish functional computed tomography (CT) imaging as a method for assessing tumor-induced angiogenesis. Functional CT imaging was mathematically analyzed for 14 renal cell carcinomas by means of two-compartment modeling using a computer-discretization approach. The model incorporated diffusible kinetics of contrast medium including leakage from the capillary to the extravascular compartment and back-flux to the capillary compartment. The correlations between functional CT parameters [relative blood volume (rbv), permeability 1 (Pm1), and permeability 2 (Pm2)] and histopathological markers of angiogenesis [microvessel density (MVD) and vascular endothelial growth factor (VEGF)] were statistically analyzed. The modeling was successfully performed, showing similarity between the mathematically simulated curve and the measured time-density curve. There were significant linear correlations between MVD grade and Pm1 (r=0.841, P=0.001) and between VEGF grade and Pm2 (r=0.804, P=0.005) by Pearson's correlation coefficient. This method may be a useful tool for the assessment of tumor-induced angiogenesis. (author)

  3. A general class of preconditioners for statistical iterative reconstruction of emission computed tomography

    International Nuclear Information System (INIS)

    Chinn, G.; Huang, S.C.

    1997-01-01

    A major drawback of statistical iterative image reconstruction for emission computed tomography is its high computational cost. The ill-posed nature of tomography leads to slow convergence for standard gradient-based iterative approaches such as the steepest descent or the conjugate gradient algorithm. In this paper new theory and methods for a class of preconditioners are developed for accelerating the convergence rate of iterative reconstruction. To demonstrate the potential of this class of preconditioners, a preconditioned conjugate gradient (PCG) iterative algorithm for weighted least squares reconstruction (WLS) was formulated for emission tomography. Using simulated positron emission tomography (PET) data of the Hoffman brain phantom, it was shown that the convergence rate of the PCG can reduce the number of iterations of the standard conjugate gradient algorithm by a factor of 2--8 times depending on the convergence criterion

  4. Evaluation of resectability of renal cell carcinoma by computed tomography

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Matsumoto, Kunihiko; Tatezawa, Takashi; Kikuchi, Yoichi; Akisada, Masahiro; Kitagawa, Ryuichi

    1982-01-01

    Renal cell carcinoma is one of the unique neoplasm which is characterized by disappearing of the metastatic tumors after removal of the primary lesion. Angiography has been performed to evaluate the resectability of the primary tumor by nephrectomy in the past. With the use of computed tomography, detailed evaluation of the retroperitoneal structures is now possible. We have evaluated the resectability of renal cell tumor by computed tomography and compared the results with the angiographic findings and operative findings. Computed tomography is very accurate in determining the extent of the tumor especially in evaluation of tumor and the Gerota's fascia, which is essential to determine the resectability of the tumor. Informations about lymph node metastasis and invasion to the renal veins or inferior vena cava are also obtained.FIn most of the cases, angiography can be spared if computed tomography is properly performed. (author)

  5. Laryngopyocele: signs on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nazaroglu, Hasan E-mail: hnazarog@dicle.edu.tr; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual.

  6. Laryngopyocele: signs on computed tomography

    International Nuclear Information System (INIS)

    Nazaroglu, Hasan; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual

  7. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  8. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  9. Computed tomography in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki

    1990-01-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.)

  10. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  11. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  12. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  13. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  14. Comparison of computed tomography dose reporting software

    International Nuclear Information System (INIS)

    Abdullah, A.; Sun, Z.; Pongnapang, N.; Ng, K. H.

    2008-01-01

    Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover (Germany)), ImPACT CT Patients Dosimetry Calculator (version 0.99x, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck (Germany)), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen (Germany)) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen (Germany)) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly. (authors)

  15. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shirvani, Shervin M.; Komaki, Ritsuko; Heymach, John V.; Fossella, Frank V.; Chang, Joe Y.

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non–small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39–86). The median follow-up duration was 21 months (range, 4–58) in all patients and 26 months (range, 4–58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive

  16. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shirvani, Shervin M.; Komaki, Ritsuko [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Heymach, John V.; Fossella, Frank V. [Department of Thoracic/Head and Neck Medical Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Chang, Joe Y., E-mail: jychang@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non-small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39-86). The median follow-up duration was 21 months (range, 4-58) in all patients and 26 months (range, 4-58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive intensity

  17. Ex-situ X-ray computed tomography data for a non-crimp fabric based glass fibre composite under fatigue loading

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2017-01-01

    The data published with this article are high resolution X-ray computed tomography (CT) data obtained during an ex-situ fatigue test of a coupon test specimen made from a non-crimp fabric based glass fibre composite similar to those used for wind turbine blades. The fatigue test was interrupted...

  18. Computer Based Modelling and Simulation

    Indian Academy of Sciences (India)

    GENERAL I ARTICLE. Computer Based ... universities, and later did system analysis, ... sonal computers (PC) and low cost software packages and tools. They can serve as useful learning experience through student projects. Models are .... Let us consider a numerical example: to calculate the velocity of a trainer aircraft ...

  19. Computed tomography of cryogenic cells

    International Nuclear Information System (INIS)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-01-01

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions

  20. Computed tomography of the central nervous system in small animals

    International Nuclear Information System (INIS)

    Tipold, A.; Tipold, E.

    1991-01-01

    With computed tomography in 44 small animals some well defined anatomical structures and pathological processes of the central nervous system are described. Computed tomography is not only necessary for the diagnosis of tumors; malformations, inflammatory, degenerative and vascular diseases and traumas are also visible

  1. Evaluation of transurethral ultrasonography and computed tomography in the staging of bladder tumors

    International Nuclear Information System (INIS)

    Yamakawa, Kensuke; Hoshina, Akira; Tochigi, Hiromi; Kawamura, Juichi

    1987-01-01

    A definitive pathologic diagnosis was made in 47 patients with bladder tumors from cystectomy specimens or by surgical exploration. The tumor was staged in 35 cases by transurethral ultrasonography and in 39 cases by computed tomography. We obtained the following results : the accuracy was 83 % using transurethral sonography, 77 % using computed tomography. Although transurethral ultrasonography is more advantageous than computed tomography in the low stage in regard to accuracy, computed tomography is excellent method to obtain information about the tumor invasion and/or metastases. Of 25 cases combind with computed tomography and transurethral sonography. tumors were correctly staged by both methods in 18 cases (72 %). Histopathological stage was consistent with neither ultrasonographic stage nor computed tomographic stage in 2 cases, and any of these tumors was correctly staged by either of these methods. Although transurethral ultrasonography and computed tomography improve the clinical stage of the bladder tumors separately, some limitations and problems was recognized on using together with these methods for staging the bladder tumors. (author)

  2. Computed tomography of the llama head: technique and normal anatomy

    International Nuclear Information System (INIS)

    Hathcock, J.T.; Pugh, D.G.; Cartee, R.E.; Hammond, L.

    1996-01-01

    Computed tomography was performed on the head of 6 normal adult llamas. The animals were under general anesthesia and positioned in dorsal recumbency on the scanning table. The area scanned was from the external occipital protuberance to the rostral portion of the nasal passage, and the images are presented in both a bone window and a soft tissue window to allow evaluation and identification of the anatomy of the head. Computed tomography of the llama head can be accomplished by most computed tomography scanners utilizing a technique similar to that used in small animals with minor modification of the scanning table

  3. A computed tomography-based spatial normalization for the analysis of [18F] fluorodeoxyglucose positron emission tomography of the brain.

    Science.gov (United States)

    Cho, Hanna; Kim, Jin Su; Choi, Jae Yong; Ryu, Young Hoon; Lyoo, Chul Hyoung

    2014-01-01

    We developed a new computed tomography (CT)-based spatial normalization method and CT template to demonstrate its usefulness in spatial normalization of positron emission tomography (PET) images with [(18)F] fluorodeoxyglucose (FDG) PET studies in healthy controls. Seventy healthy controls underwent brain CT scan (120 KeV, 180 mAs, and 3 mm of thickness) and [(18)F] FDG PET scans using a PET/CT scanner. T1-weighted magnetic resonance (MR) images were acquired for all subjects. By averaging skull-stripped and spatially-normalized MR and CT images, we created skull-stripped MR and CT templates for spatial normalization. The skull-stripped MR and CT images were spatially normalized to each structural template. PET images were spatially normalized by applying spatial transformation parameters to normalize skull-stripped MR and CT images. A conventional perfusion PET template was used for PET-based spatial normalization. Regional standardized uptake values (SUV) measured by overlaying the template volume of interest (VOI) were compared to those measured with FreeSurfer-generated VOI (FSVOI). All three spatial normalization methods underestimated regional SUV values by 0.3-20% compared to those measured with FSVOI. The CT-based method showed slightly greater underestimation bias. Regional SUV values derived from all three spatial normalization methods were correlated significantly (p normalization may be an alternative method for structure-based spatial normalization of [(18)F] FDG PET when MR imaging is unavailable. Therefore, it is useful for PET/CT studies with various radiotracers whose uptake is expected to be limited to specific brain regions or highly variable within study population.

  4. Multi-Detector Computed Tomography Imaging Techniques in Arterial Injuries

    Directory of Open Access Journals (Sweden)

    Cameron Adler

    2018-04-01

    Full Text Available Cross-sectional imaging has become a critical aspect in the evaluation of arterial injuries. In particular, angiography using computed tomography (CT is the imaging of choice. A variety of techniques and options are available when evaluating for arterial injuries. Techniques involve contrast bolus, various phases of contrast enhancement, multiplanar reconstruction, volume rendering, and maximum intensity projection. After the images are rendered, a variety of features may be seen that diagnose the injury. This article provides a general overview of the techniques, important findings, and pitfalls in cross sectional imaging of arterial imaging, particularly in relation to computed tomography. In addition, the future directions of computed tomography, including a few techniques in the process of development, is also discussed.

  5. A cone-beam computed tomography triple scan procedure to obtain a three-dimensional augmented virtual skull model appropriate for orthognathic surgery planning.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Clercq, C. De; Abeloos, J.V.S.; Lamoral, P.; Lippens, F.R.C.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan

  6. Difficulties encountered managing nodules detected during a computed tomography lung cancer screening program.

    Science.gov (United States)

    Veronesi, Giulia; Bellomi, Massimo; Scanagatta, Paolo; Preda, Lorenzo; Rampinelli, Cristiano; Guarize, Juliana; Pelosi, Giuseppe; Maisonneuve, Patrick; Leo, Francesco; Solli, Piergiorgio; Masullo, Michele; Spaggiari, Lorenzo

    2008-09-01

    The main challenge of screening a healthy population with low-dose computed tomography is to balance the excessive use of diagnostic procedures with the risk of delayed cancer detection. We evaluated the pitfalls, difficulties, and sources of mistakes in the management of lung nodules detected in volunteers in the Cosmos single-center screening trial. A total of 5201 asymptomatic high-risk volunteers underwent screening with multidetector low-dose computed tomography. Nodules detected at baseline or new nodules at annual screening received repeat low-dose computed tomography at 1 year if less than 5 mm, repeat low-dose computed tomography 3 to 6 months later if between 5 and 8 mm, and fluorodeoxyglucose positron emission tomography if more than 8 mm. Growing nodules at the annual screening received low-dose computed tomography at 6 months and computed tomography-positron emission tomography or surgical biopsy according to doubling time, type, and size. During the first year of screening, 106 patients underwent lung biopsy and 91 lung cancers were identified (70% were stage I). Diagnosis was delayed (false-negative) in 6 patients (stage IIB in 1 patient, stage IIIA in 3 patients, and stage IV in 2 patients), including 2 small cell cancers and 1 central lesion. Surgical biopsy revealed benign disease (false-positives) in 15 cases (14%). Positron emission tomography sensitivity was 88% for prevalent cancers and 70% for cancers diagnosed after first annual screening. No needle biopsy procedures were performed in this cohort of patients. Low-dose computed tomography screening is effective for the early detection of lung cancers, but nodule management remains a challenge. Computed tomography-positron emission tomography is useful at baseline, but its sensitivity decreases significantly the subsequent year. Multidisciplinary management and experience are crucial for minimizing misdiagnoses.

  7. Intravenous contrast media application using cone-beam computed tomography in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Sung; Kim, Bok Yeol; Choi, Hwa Young [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of); and others

    2015-03-15

    This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

  8. Intravenous contrast media application using cone-beam computed tomography in a rabbit model

    International Nuclear Information System (INIS)

    Kim, Min Sung; Kim, Bok Yeol; Choi, Hwa Young

    2015-01-01

    This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

  9. Computed tomography as a tool for tolerance verification of industrial parts

    DEFF Research Database (Denmark)

    Müller, Pavel; Cantatore, Angela; Andreasen, J.L.

    2013-01-01

    Computed tomography (CT) is becoming an important technology for industrial applications, enabling fast and accurate control of manufactured parts. In only a few minutes, a complete 3D model of a part may be obtained, allowing measurements of external and internal features. This paper presents...

  10. Ultrasonography and computer tomography in the diagnosis of certain abdominal diseases

    International Nuclear Information System (INIS)

    Wawrzynek, Z.

    1981-01-01

    Ultrasonography and computer tomography in the diagnosis of digestive tract and spleen diseases as well as traumas are compared. It is concluded that ultrasonography is nearly as usefull as computer tomography. (author)

  11. Occult primary tumors of the head and neck: accuracy of thallium 201 single-photon emission computed tomography and computed tomography and/or magnetic resonance imaging

    NARCIS (Netherlands)

    van Veen, S. A.; Balm, A. J.; Valdés Olmos, R. A.; Hoefnagel, C. A.; Hilgers, F. J.; Tan, I. B.; Pameijer, F. A.

    2001-01-01

    To determine the accuracy of thallium 201 single-photon emission computed tomography (thallium SPECT) and computed tomography and/or magnetic resonance imaging (CT/MRI) in the detection of occult primary tumors of the head and neck. Study of diagnostic tests. National Cancer Institute, Amsterdam,

  12. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  13. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Golimbu, C.; Bonamo, J.

    1984-01-01

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  14. The value of computer tomography and sonography in the investigation of the pancreas

    International Nuclear Information System (INIS)

    Lackner, K.; Frommhold, H.; Grauthoff, H.; Moedder, U.; Heuser, L.; Braun, G.; Buurman, R.; Scherer, K.; Hamburg Univ.; Koeln Univ.

    1980-01-01

    Three hundred and five patients were examined by computer tomography and sonography. In 117 patients no abnormalities were found in the pancreas. The accuracy of computer tomography was 87%, of sonography 85%. In 41 patients the presence of a carcinoma of the pancreas was confirmed histologically. In this group the sensitivity of computer tomography was 83%, of sonography 85%. Thirty-four patients suffered from acute pancreatitis. In this group sensitivity of the two methods was equal at 79%. 113 patients had changes of chronic pancreatitis. Sensitivity of computer tomography was 84%, of sonography 70%. Computer tomography is better at demonstrating calcification in the pancreas. Atrophy of the pancreas cannot be diagnosed by sonography. (orig.) [de

  15. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  16. Computed tomography of the mediastinum in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours.

  17. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  19. Modeling soft factors in computer-based wargames

    Science.gov (United States)

    Alexander, Steven M.; Ross, David O.; Vinarskai, Jonathan S.; Farr, Steven D.

    2002-07-01

    Computer-based wargames have seen much improvement in recent years due to rapid increases in computing power. Because these games have been developed for the entertainment industry, most of these advances have centered on the graphics, sound, and user interfaces integrated into these wargames with less attention paid to the game's fidelity. However, for a wargame to be useful to the military, it must closely approximate as many of the elements of war as possible. Among the elements that are typically not modeled or are poorly modeled in nearly all military computer-based wargames are systematic effects, command and control, intelligence, morale, training, and other human and political factors. These aspects of war, with the possible exception of systematic effects, are individually modeled quite well in many board-based commercial wargames. The work described in this paper focuses on incorporating these elements from the board-based games into a computer-based wargame. This paper will also address the modeling and simulation of the systemic paralysis of an adversary that is implied by the concept of Effects Based Operations (EBO). Combining the fidelity of current commercial board wargames with the speed, ease of use, and advanced visualization of the computer can significantly improve the effectiveness of military decision making and education. Once in place, the process of converting board wargames concepts to computer wargames will allow the infusion of soft factors into military training and planning.

  20. Investigation of a pre-clinical mandibular bone notch defect model in miniature pigs: clinical computed tomography, micro-computed tomography, and histological evaluation.

    Science.gov (United States)

    Carlisle, Patricia L; Guda, Teja; Silliman, David T; Lien, Wen; Hale, Robert G; Brown Baer, Pamela R

    2016-02-01

    To validate a critical-size mandibular bone defect model in miniature pigs. Bilateral notch defects were produced in the mandible of dentally mature miniature pigs. The right mandibular defect remained untreated while the left defect received an autograft. Bone healing was evaluated by computed tomography (CT) at 4 and 16 weeks, and by micro-CT and non-decalcified histology at 16 weeks. In both the untreated and autograft treated groups, mineralized tissue volume was reduced significantly at 4 weeks post-surgery, but was comparable to the pre-surgery levels after 16 weeks. After 16 weeks, CT analysis indicated that significantly greater bone was regenerated in the autograft treated defect than in the untreated defect (P=0.013). Regardless of the treatment, the cortical bone was superior to the defect remodeled over 16 weeks to compensate for the notch defect. The presence of considerable bone healing in both treated and untreated groups suggests that this model is inadequate as a critical-size defect. Despite healing and adaptation, the original bone geometry and quality of the pre-injured mandible was not obtained. On the other hand, this model is justified for evaluating accelerated healing and mitigating the bone remodeling response, which are both important considerations for dental implant restorations.

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... information about radiation dose. There always is a risk of complications from general anesthesia or sedation. Every measure will be taken to ... in X-Ray and CT Exams Contrast Materials Anesthesia Safety Children and Radiation Safety ... (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) ...

  2. Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

    International Nuclear Information System (INIS)

    Chen, Dongmei; Zhu, Shouping; Chen, Xueli; Chao, Tiantian; Cao, Xu; Zhao, Fengjun; Huang, Liyu; Liang, Jimin

    2014-01-01

    X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging

  3. Imaging performance of a hybrid x-ray computed tomography-fluorescence molecular tomography system using priors.

    Science.gov (United States)

    Ale, Angelique; Schulz, Ralf B; Sarantopoulos, Athanasios; Ntziachristos, Vasilis

    2010-05-01

    The performance is studied of two newly introduced and previously suggested methods that incorporate priors into inversion schemes associated with data from a recently developed hybrid x-ray computed tomography and fluorescence molecular tomography system, the latter based on CCD camera photon detection. The unique data set studied attains accurately registered data of high spatially sampled photon fields propagating through tissue along 360 degrees projections. Approaches that incorporate structural prior information were included in the inverse problem by adding a penalty term to the minimization function utilized for image reconstructions. Results were compared as to their performance with simulated and experimental data from a lung inflammation animal model and against the inversions achieved when not using priors. The importance of using priors over stand-alone inversions is also showcased with high spatial sampling simulated and experimental data. The approach of optimal performance in resolving fluorescent biodistribution in small animals is also discussed. Inclusion of prior information from x-ray CT data in the reconstruction of the fluorescence biodistribution leads to improved agreement between the reconstruction and validation images for both simulated and experimental data.

  4. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    Carrascosa, Patricia M.; Vallejos, J.; Capunay, Carlos M.; Deviggiano, A.; Carrascosa, Jorge M.

    2007-01-01

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine [es

  5. Quantification of lung fibrosis and emphysema in mice using automated micro-computed tomography.

    Directory of Open Access Journals (Sweden)

    Ellen De Langhe

    Full Text Available BACKGROUND: In vivo high-resolution micro-computed tomography allows for longitudinal image-based measurements in animal models of lung disease. The combination of repetitive high resolution imaging with fully automated quantitative image analysis in mouse models of lung fibrosis lung benefits preclinical research. This study aimed to develop and validate such an automated micro-computed tomography analysis algorithm for quantification of aerated lung volume in mice; an indicator of pulmonary fibrosis and emphysema severity. METHODOLOGY: Mice received an intratracheal instillation of bleomycin (n = 8, elastase (0.25 U elastase n = 9, 0.5 U elastase n = 8 or saline control (n = 6 for fibrosis, n = 5 for emphysema. A subset of mice was scanned without intervention, to evaluate potential radiation-induced toxicity (n = 4. Some bleomycin-instilled mice were treated with imatinib for proof of concept (n = 8. Mice were scanned weekly, until four weeks after induction, when they underwent pulmonary function testing, lung histology and collagen quantification. Aerated lung volumes were calculated with our automated algorithm. PRINCIPAL FINDINGS: Our automated image-based aerated lung volume quantification method is reproducible with low intra-subject variability. Bleomycin-treated mice had significantly lower scan-derived aerated lung volumes, compared to controls. Aerated lung volume correlated with the histopathological fibrosis score and total lung collagen content. Inversely, a dose-dependent increase in lung volume was observed in elastase-treated mice. Serial scanning of individual mice is feasible and visualized dynamic disease progression. No radiation-induced toxicity was observed. Three-dimensional images provided critical topographical information. CONCLUSIONS: We report on a high resolution in vivo micro-computed tomography image analysis algorithm that runs fully automated and allows quantification of aerated lung volume in mice. This

  6. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  7. X-ray computed tomography using curvelet sparse regularization.

    Science.gov (United States)

    Wieczorek, Matthias; Frikel, Jürgen; Vogel, Jakob; Eggl, Elena; Kopp, Felix; Noël, Peter B; Pfeiffer, Franz; Demaret, Laurent; Lasser, Tobias

    2015-04-01

    Reconstruction of x-ray computed tomography (CT) data remains a mathematically challenging problem in medical imaging. Complementing the standard analytical reconstruction methods, sparse regularization is growing in importance, as it allows inclusion of prior knowledge. The paper presents a method for sparse regularization based on the curvelet frame for the application to iterative reconstruction in x-ray computed tomography. In this work, the authors present an iterative reconstruction approach based on the alternating direction method of multipliers using curvelet sparse regularization. Evaluation of the method is performed on a specifically crafted numerical phantom dataset to highlight the method's strengths. Additional evaluation is performed on two real datasets from commercial scanners with different noise characteristics, a clinical bone sample acquired in a micro-CT and a human abdomen scanned in a diagnostic CT. The results clearly illustrate that curvelet sparse regularization has characteristic strengths. In particular, it improves the restoration and resolution of highly directional, high contrast features with smooth contrast variations. The authors also compare this approach to the popular technique of total variation and to traditional filtered backprojection. The authors conclude that curvelet sparse regularization is able to improve reconstruction quality by reducing noise while preserving highly directional features.

  8. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  9. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  10. Seismocardiography-Based Cardiac Computed Tomography Gating Using Patient-Specific Template Identification and Detection.

    Science.gov (United States)

    Yao, Jingting; Tridandapani, Srini; Wick, Carson A; Bhatti, Pamela T

    2017-01-01

    To more accurately trigger cardiac computed tomography angiography (CTA) than electrocardiography (ECG) alone, a sub-system is proposed as an intermediate step toward fusing ECG with seismocardiography (SCG). Accurate prediction of quiescent phases is crucial to prospectively gating CTA, which is susceptible to cardiac motion and, thus, can affect the diagnostic quality of images. The key innovation of this sub-system is that it identifies the SCG waveform corresponding to heart sounds and determines their phases within the cardiac cycles. Furthermore, this relationship is modeled as a linear function with respect to heart rate. For this paper, B-mode echocardiography is used as the gold standard for identifying the quiescent phases. We analyzed synchronous ECG, SCG, and echocardiography data acquired from seven healthy subjects (mean age: 31; age range: 22-48; males: 4) and 11 cardiac patients (mean age: 56; age range: 31-78; males: 6). On average, the proposed algorithm was able to successfully identify 79% of the SCG waveforms in systole and 68% in diastole. The simulated results show that SCG-based prediction produced less average phase error than that of ECG. It was found that the accuracy of ECG-based gating is more susceptible to increases in heart rate variability, while SCG-based gating is susceptible to high cycle to cycle variability in morphology. This pilot work of prediction using SCG waveforms enriches the framework of a comprehensive system with multiple modalities that could potentially, in real time, improve the image quality of CTA.

  11. Computed tomography of the mediastinum in myasthenia gravis

    International Nuclear Information System (INIS)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.; Hamburg Univ.; Hamburg Univ.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours. (orig.) [de

  12. Computed tomography in the evaluation of acquired stenosis in the neonate

    International Nuclear Information System (INIS)

    Faw, K.; Muntz, H.; Siegel, M.; Spector, G.

    1982-01-01

    We studied the feasibility of computed tomographic evaluation of the neonatal airway. Three neonatal larynges, removed at necroscopy, were examined by computed tomography. Good resolution of soft tissue, cartilage and airway lumen was obtained in these small specimens. On the basis of these findings two neonates with acquired subglottic stenosis were examined by endoscopy, soft tissue airway radiographs, and computed tomography. Measurements of radiation dose revealed that a computed tomographic study delivered 36% of the mean tissue dose of standard image intensifier fluoroscopy. Computed tomography and fluoroscopy both demonstrated the degree and length of this stenosis accurately. An advantage of CT over conventional imaging procedures was better definition of the cross sectional area of the airway

  13. Coupling of EIT with computational lung modeling for predicting patient-specific ventilatory responses.

    Science.gov (United States)

    Roth, Christian J; Becher, Tobias; Frerichs, Inéz; Weiler, Norbert; Wall, Wolfgang A

    2017-04-01

    Providing optimal personalized mechanical ventilation for patients with acute or chronic respiratory failure is still a challenge within a clinical setting for each case anew. In this article, we integrate electrical impedance tomography (EIT) monitoring into a powerful patient-specific computational lung model to create an approach for personalizing protective ventilatory treatment. The underlying computational lung model is based on a single computed tomography scan and able to predict global airflow quantities, as well as local tissue aeration and strains for any ventilation maneuver. For validation, a novel "virtual EIT" module is added to our computational lung model, allowing to simulate EIT images based on the patient's thorax geometry and the results of our numerically predicted tissue aeration. Clinically measured EIT images are not used to calibrate the computational model. Thus they provide an independent method to validate the computational predictions at high temporal resolution. The performance of this coupling approach has been tested in an example patient with acute respiratory distress syndrome. The method shows good agreement between computationally predicted and clinically measured airflow data and EIT images. These results imply that the proposed framework can be used for numerical prediction of patient-specific responses to certain therapeutic measures before applying them to an actual patient. In the long run, definition of patient-specific optimal ventilation protocols might be assisted by computational modeling. NEW & NOTEWORTHY In this work, we present a patient-specific computational lung model that is able to predict global and local ventilatory quantities for a given patient and any selected ventilation protocol. For the first time, such a predictive lung model is equipped with a virtual electrical impedance tomography module allowing real-time validation of the computed results with the patient measurements. First promising results

  14. Three-dimensional reconstruction and modeling of middle ear biomechanics by high-resolution computed tomography and finite element analysis.

    Science.gov (United States)

    Lee, Chia-Fone; Chen, Peir-Rong; Lee, Wen-Jeng; Chen, Jyh-Horng; Liu, Tien-Chen

    2006-05-01

    To present a systematic and practical approach that uses high-resolution computed tomography to derive models of the middle ear for finite element analysis. This prospective study included 31 subjects with normal hearing and no previous otologic disorders. Temporal bone images obtained from 15 right ears and 16 left ears were used for evaluation and reconstruction. High-resolution computed tomography of temporal bone was performed using simultaneous acquisition of 16 sections with a collimated slice thickness of 0.625 mm. All images were transferred to an Amira visualization system for three-dimensional reconstruction. The created three-dimensional model was translated into two commercial modeling packages, Patran and ANSYS, for finite element analysis. The characteristic dimensions of the model were measured and compared with previously published histologic section data. This result confirms that the geometric model created by the proposed method is accurate except that the tympanic membrane is thicker than when measured by the histologic section method. No obvious difference in the geometrical dimension between right and left ossicles was found (P > .05). The three-dimensional model created by finite element method and predicted umbo and stapes displacements are close to the bounds of the experimental curves of Nishihara's, Huber's, Gan's, and Sun's data across the frequency range of 100 to 8000 Hz. The model includes a description of the geometry of the middle ear components and dynamic equations of vibration. The proposed method is quick, practical, low-cost, and, most importantly, noninvasive as compared with histologic section methods.

  15. Computer Based Modelling and Simulation

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 3. Computer Based Modelling and Simulation - Modelling Deterministic Systems. N K Srinivasan. General Article Volume 6 Issue 3 March 2001 pp 46-54. Fulltext. Click here to view fulltext PDF. Permanent link:

  16. Logistic regression model for identification of right ventricular dysfunction in patients with acute pulmonary embolism by means of computed tomography

    International Nuclear Information System (INIS)

    Staskiewicz, Grzegorz; Czekajska-Chehab, Elżbieta; Uhlig, Sebastian; Przegalinski, Jerzy; Maciejewski, Ryszard; Drop, Andrzej

    2013-01-01

    Purpose: Diagnosis of right ventricular dysfunction in patients with acute pulmonary embolism (PE) is known to be associated with increased risk of mortality. The aim of the study was to calculate a logistic regression model for reliable identification of right ventricular dysfunction (RVD) in patients diagnosed with computed tomography pulmonary angiography. Material and methods: Ninety-seven consecutive patients with acute pulmonary embolism were divided into groups with and without RVD basing upon echocardiographic measurement of pulmonary artery systolic pressure (PASP). PE severity was graded with the pulmonary obstruction score. CT measurements of heart chambers and mediastinal vessels were performed; position of interventricular septum and presence of contrast reflux into the inferior vena cava were also recorded. The logistic regression model was prepared by means of stepwise logistic regression. Results: Among the used parameters, the final model consisted of pulmonary obstruction score, short axis diameter of right ventricle and diameter of inferior vena cava. The calculated model is characterized by 79% sensitivity and 81% specificity, and its performance was significantly better than single CT-based measurements. Conclusion: Logistic regression model identifies RVD significantly better, than single CT-based measurements

  17. Computed tomography of human joints and radioactive waste drums

    International Nuclear Information System (INIS)

    Martz, Harry E.; Roberson, G. Patrick; Hollerbach, Karin; Logan, Clinton M.; Ashby, Elaine; Bernardi, Richard

    1999-01-01

    X- and gamma-ray imaging techniques in nondestructive evaluation (NDE) and assay (NDA) have seen increasing use in an array of industrial, environmental, military, and medical applications. Much of this growth in recent years is attributed to the rapid development of computed tomography (CT) and the use of NDE throughout the life-cycle of a product. Two diverse examples of CT are discussed, 1.) Our computational approach to normal joint kinematics and prosthetic joint analysis offers an opportunity to evaluate and improve prosthetic human joint replacements before they are manufactured or surgically implanted. Computed tomography data from scanned joints are segmented, resulting in the identification of bone and other tissues of interest, with emphasis on the articular surfaces. 2.) We are developing NDE and NDA techniques to analyze closed waste drums accurately and quantitatively. Active and passive computed tomography (A and PCT) is a comprehensive and accurate gamma-ray NDA method that can identify all detectable radioisotopes present in a container and measure their radioactivity

  18. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  19. Initial water quantification results using neutron computed tomography

    Science.gov (United States)

    Heller, A. K.; Shi, L.; Brenizer, J. S.; Mench, M. M.

    2009-06-01

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at the Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  20. Multislice helical computed tomography in the evaluation of lumbar spine diseases

    International Nuclear Information System (INIS)

    Rosemberg, Laercio Alberto; Rios, Adriana Martins; Almeida, Milena Oliveira; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao

    2003-01-01

    Multislice computed tomography has advantages in comparison to conventional computer tomography such as reduction in study time, lower radiation dose, fewer metal artifacts and high quality multiplanar reformatting and three-dimensional reconstructions. We reviewed approximately 300 lumbar spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms traumatic injuries, spondylolysis and postoperative changes. In the majority of the cases the high quality multiplanar reformatted and volume reconstructions of multislice computed tomography allowed better evaluation of the lesions, particularly in the cases of complex anatomy (author)

  1. Influence of computer tomography on radiological diagnostics of malignant tumors

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, P.; Glueck, E.; Siems, H.

    1981-01-01

    A survey is presented of the present status of cancer diagnostics in the following organs and organ systems: neurocranium, visceral cranium and base of skull, larynx and thyroid, thorax, pancreas, retroperitoneum, kidneys and adrenal glands, pelvis, and skeletal system. The rank of computer tomography is compared with those of other examination techniques.

  2. The history of computed tomography

    International Nuclear Information System (INIS)

    Bull, J.

    1980-01-01

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ) [de

  3. Computed tomography-based subclassification of chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Dirksen, Asger; Wille, Mathilde M W

    2016-01-01

    Computed tomography (CT) is an obvious modality for subclassification of COPD. Traditionally, the pulmonary involvement of chronic obstructive pulmonary disease (COPD) in smokers is understood as a combination of deleterious effects of smoking on small airways (chronic bronchitis and small airways...... observed in COPD are subtle. Furthermore, recent results indicate that emphysema may also be the essential pathophysiologic mechanism behind the airflow limitation of COPD. The definition of COPD excludes bronchiectasis as a symptomatic subtype of COPD, and CT findings in chronic bronchitis...... and exacerbations of COPD are rather unspecific. This leaves emphysema as the most obvious candidate for subclassification of COPD. Both chest radiologists and pulmonary physicians are quite familiar with the appearance of various patterns of emphysema on HRCT, such as centrilobular, panlobular, and paraseptal...

  4. Morphometric analysis - Cone beam computed tomography to predict bone quality and quantity.

    Science.gov (United States)

    Hohlweg-Majert, B; Metzger, M C; Kummer, T; Schulze, D

    2011-07-01

    Modified quantitative computed tomography is a method used to predict bone quality and quantify the bone mass of the jaw. The aim of this study was to determine whether bone quantity or quality was detected by cone beam computed tomography (CBCT) combined with image analysis. MATERIALS AND PROCEDURES: Different measurements recorded on two phantoms (Siemens phantom, Comac phantom) were evaluated on images taken with the Somatom VolumeZoom (Siemens Medical Solutions, Erlangen, Germany) and the NewTom 9000 (NIM s.r.l., Verona, Italy) in order to calculate a calibration curve. The spatial relationships of six sample cylinders and the repositioning from four pig skull halves relative to adjacent defined anatomical structures were assessed by means of three-dimensional visualization software. The calibration curves for computer tomography (CT) and cone beam computer tomography (CBCT) using the Siemens phantom showed linear correlation in both modalities between the Hounsfield Units (HU) and bone morphology. A correction factor for CBCT was calculated. Exact information about the micromorphology of the bone cylinders was only available using of micro computer tomography. Cone-beam computer tomography is a suitable choice for analysing bone mass, but, it does not give any information about bone quality. 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Inversion based on computational simulations

    International Nuclear Information System (INIS)

    Hanson, K.M.; Cunningham, G.S.; Saquib, S.S.

    1998-01-01

    A standard approach to solving inversion problems that involve many parameters uses gradient-based optimization to find the parameters that best match the data. The authors discuss enabling techniques that facilitate application of this approach to large-scale computational simulations, which are the only way to investigate many complex physical phenomena. Such simulations may not seem to lend themselves to calculation of the gradient with respect to numerous parameters. However, adjoint differentiation allows one to efficiently compute the gradient of an objective function with respect to all the variables of a simulation. When combined with advanced gradient-based optimization algorithms, adjoint differentiation permits one to solve very large problems of optimization or parameter estimation. These techniques will be illustrated through the simulation of the time-dependent diffusion of infrared light through tissue, which has been used to perform optical tomography. The techniques discussed have a wide range of applicability to modeling including the optimization of models to achieve a desired design goal

  6. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)

  7. Diagnosis of dementia with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Jagust, W.J.; Budinger, T.F.; Reed, B.R.

    1987-01-01

    Single photon emission computed tomography is a practical modality for the study of physiologic cerebral activity in vivo. We utilized single photon emission computed tomography and N-isopropyl-p-iodoamphetamine iodine 123 to evaluate regional cerebral blood flow in nine patients with Alzheimer's disease (AD), five healthy elderly control subjects, and two patients with multi-infarct dementia. We found that all subjects with AD demonstrated flow deficits in temporoparietal cortex bilaterally, and that the ratio of activity in bilateral temporoparietal cortex to activity in the whole slice allowed the differentiation of all patients with AD from both the controls and from the patients with multi-infarct dementia. Furthermore, this ratio showed a strong correlation with disease severity in the AD group. Single photon emission computed tomography appears to be useful in the differential diagnosis of dementia and reflects clinical features of the disease

  8. F-18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Appearance of Extramedullary Hematopoesis in a Case of Primary Myelofibrosis

    Science.gov (United States)

    Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    A 44-year-old female with known primary myelofibrosis presented with shortness of breath. High Resolution Computed Tomography thorax revealed large heterogeneously enhancing extraparenchymal soft tissue density mass involving bilateral lung fields. F-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography revealed mildly FDG avid soft tissue density mass with specks of calcification involving bilateral lung fields, liver, and spleen. Subsequent histopathologic evaluation from the right lung mass was suggestive of extramedullary hematopoesis. PMID:28533647

  9. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    Energy Technology Data Exchange (ETDEWEB)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients.

  10. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    International Nuclear Information System (INIS)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients

  11. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji [Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2015-03-15

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  12. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    International Nuclear Information System (INIS)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji

    2015-01-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  13. Comparing staging by positron emission tomography with contrast-enhanced computed tomography and by pathology in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Qualliotine, J R; Mydlarz, W K; Chan, J Y K; Zhou, X; Wang, H; Agrawal, N

    2015-12-01

    This study aimed to evaluate the ability of positron emission tomography with contrast-enhanced computed tomography to correctly stage head and neck squamous cell carcinomas, in comparison with pathological staging. Positron emission tomography computed tomography was used to determine the tumour-node-metastasis classification and overall cancer stage in 85 head and neck squamous cell carcinoma patients who underwent pre-operative imaging using this modality and primary surgery between July 2010 and January 2013. Staging by positron emission tomography computed tomography was retrospectively compared with staging using pathological specimens. Agreement between imaging stage and pathological stage was examined by univariate and multivariate analysis both overall and for each primary tumour site. This imaging modality was 87.5 per cent sensitive and 44.8 per cent specific in identifying regional cervical metastases, and had false positive and false negative rates of 18.8 per cent and 8.2 per cent, respectively. The positive predictive and negative predictive values were 75.4 per cent and 65.0 per cent, respectively. Univariate and multivariate analyses revealed a significant agreement between positron emission tomography computed tomography and pathological node classification in older patients and for the oral cavity primary tumour site. There was significant agreement between both methods in the overall classification only for tumours classified as T3 or greater. Positron emission tomography computed tomography should be used with caution for the pre-operative staging of head and neck cancers because of its high false positive and false negative rates.

  14. Accounting for sub-resolution pores in models of water and solute transport in soils based on computed tomography images: Are we there yet?

    Science.gov (United States)

    Baveye, Philippe C.; Pot, Valérie; Garnier, Patricia

    2017-12-01

    In the last decade, X-ray computed tomography (CT) has become widely used to characterize the geometry and topology of the pore space of soils and natural porous media. Regardless of the resolution of CT images, a fundamental problem associated with their use, for example as a starting point in simulation efforts, is that sub-resolution pores are not detected. Over the last few years, a particular type of modeling method, known as ;Grey; or ;Partial Bounce Back; Lattice-Boltzmann (LB), has been adopted by increasing numbers of researchers to try to account for sub-resolution pores in the modeling of water and solute transport in natural porous media. In this short paper, we assess the extent to which Grey LB methods indeed offer a workable solution to the problem at hand. We conclude that, in spite of significant computational advances, a major experimental hurdle related to the evaluation of the penetrability of sub-resolution pores, is blocking the way ahead. This hurdle will need to be cleared before Grey LB can become a credible option in the microscale modeling of soils and sediments. A necessarily interdisciplinary effort, involving both modelers and experimentalists, is needed to clear the path forward.

  15. Direct estimation of human trabecular bone stiffness using cone beam computed tomography.

    Science.gov (United States)

    Klintström, Eva; Klintström, Benjamin; Pahr, Dieter; Brismar, Torkel B; Smedby, Örjan; Moreno, Rodrigo

    2018-04-10

    The aim of this study was to evaluate the possibility of estimating the biomechanical properties of trabecular bone through finite element simulations by using dental cone beam computed tomography data. Fourteen human radius specimens were scanned in 3 cone beam computed tomography devices: 3-D Accuitomo 80 (J. Morita MFG., Kyoto, Japan), NewTom 5 G (QR Verona, Verona, Italy), and Verity (Planmed, Helsinki, Finland). The imaging data were segmented by using 2 different methods. Stiffness (Young modulus), shear moduli, and the size and shape of the stiffness tensor were studied. Corresponding evaluations by using micro-CT were regarded as the reference standard. The 3-D Accuitomo 80 (J. Morita MFG., Kyoto, Japan) showed good performance in estimating stiffness and shear moduli but was sensitive to the choice of segmentation method. NewTom 5 G (QR Verona, Verona, Italy) and Verity (Planmed, Helsinki, Finland) yielded good correlations, but they were not as strong as Accuitomo 80 (J. Morita MFG., Kyoto, Japan). The cone beam computed tomography devices overestimated both stiffness and shear compared with the micro-CT estimations. Finite element-based calculations of biomechanics from cone beam computed tomography data are feasible, with strong correlations for the Accuitomo 80 scanner (J. Morita MFG., Kyoto, Japan) combined with an appropriate segmentation method. Such measurements might be useful for predicting implant survival by in vivo estimations of bone properties. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  17. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  18. Efficacy of 3D-positron emission tomography/computed tomography for upper abdomen.

    Science.gov (United States)

    Murakami, Koji; Nakahara, Tadaki

    2014-04-01

    Recent advancement in computed tomography (CT) enables us to obtain high spatial resolution image and made it possible to construct extensive high-definition three-dimensional (3D) images. But a lack of contrast resolution in CT alone is still remained problem. Meanwhile, as fluorodeoxyglucose-positron emission tomography (PET) can visualize tumors in high contrast, we can create 3D images fusing the accumulation in tumors on PET/CT images. Such images can play the role of a "map of body" which makes it easy to understand the anatomical information before surgery. We also try to evaluate segmental liver function by using PET/CT fusion images. By using (11) C-methionine PET/contrast-enhanced CT, superior image quality compared to single photon emission computed tomography/CT can be obtained. CT, especially with contrast enhancement for obtaining anatomical imaging information plus PET for obtaining functional imaging information is a highly compatible combination, and adding these two types information will further increase clinical usefulness. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  19. Computed Tomography Image Origin Identification Based on Original Sensor Pattern Noise and 3-D Image Reconstruction Algorithm Footprints.

    Science.gov (United States)

    Duan, Yuping; Bouslimi, Dalel; Yang, Guanyu; Shu, Huazhong; Coatrieux, Gouenou

    2017-07-01

    In this paper, we focus on the "blind" identification of the computed tomography (CT) scanner that has produced a CT image. To do so, we propose a set of noise features derived from the image chain acquisition and which can be used as CT-scanner footprint. Basically, we propose two approaches. The first one aims at identifying a CT scanner based on an original sensor pattern noise (OSPN) that is intrinsic to the X-ray detectors. The second one identifies an acquisition system based on the way this noise is modified by its three-dimensional (3-D) image reconstruction algorithm. As these reconstruction algorithms are manufacturer dependent and kept secret, our features are used as input to train a support vector machine (SVM) based classifier to discriminate acquisition systems. Experiments conducted on images issued from 15 different CT-scanner models of 4 distinct manufacturers demonstrate that our system identifies the origin of one CT image with a detection rate of at least 94% and that it achieves better performance than sensor pattern noise (SPN) based strategy proposed for general public camera devices.

  20. Computed tomography of the ossicles

    International Nuclear Information System (INIS)

    Chakeres, D.W.; Weider, D.J.

    1985-01-01

    Otologists and otolaryngologists have described in detail the disorders which are unique to the ossicles. However the anatomy and spectrum of pathology and anatomy of the ossicles are not familiar to most radiologists. Recent advances in computed tomography (CT) and a systematic approach to evaluation now allow accurate identification of even subtle abnormalities of the ossicles. We present the normal anatomy, ossicular abnormalities, and indications for computed tomographic study. Because of the greater diagnostic capability of CT, the radiologist's role has increased in evaluation and treatment planning of patients with suspected ossicular abnormalities. (orig.)

  1. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  2. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  3. Prior-based artifact correction (PBAC) in computed tomography

    International Nuclear Information System (INIS)

    Heußer, Thorsten; Brehm, Marcus; Ritschl, Ludwig; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. Methods: The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. Results: The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. Conclusions: The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data

  4. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  5. Computed Tomography Perfusion, Magnetic Resonance Imaging, and Histopathological Findings After Laparoscopic Renal Cryoablation: An In Vivo Pig Model

    DEFF Research Database (Denmark)

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Graumann, Ole

    2017-01-01

    The present study investigates how computed tomography perfusion scans and magnetic resonance imaging correlates with the histopathological alterations in renal tissue after cryoablation. A total of 15 pigs were subjected to laparoscopic-assisted cryoablation on both kidneys. After intervention...... of follow-up, but on microscopic examination, the urothelium was found to be intact in all cases. In conclusion, cryoablation effectively destroyed renal parenchyma, leaving the urothelium intact. Both computed tomography perfusion and magnetic resonance imaging reflect the microscopic findings...

  6. Computed tomography of thymic abnormalities: review of 10 patients

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Brito Pacheco, E.M. de; Cazerta, N.M.G.; Silva, M.J.G. da

    1990-01-01

    Chest radiographs and computed tomographic scans of the mediastinum were correlated with pathologic findings of the thymus following thymectomy in 10 patients with thymic disease. There were five patients with thymoma, four with thymic hiperplasia and one with benign thymic cyst. Computed tomography shoud be the imaging method of choice following plain chest radiographs when a suspect thymic abnormality requires further evaluation. Recognition of variations in the normal location, size, shape and density of the thymus prevents misinterpretation as abnormal mediastinal mass. Furthermore, knowledge of the normal computed tomography appearance has proved helpful in evaluating thymic abnormalities. (author)

  7. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  8. Estimation of aortic time-enhancement curve in pharmacokinetic analysis. Dynamic study by multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Yamaguchi, Isao; Kidoya, Eiji; Higashimura, Kyoji; Hayashi, Hiroyuki; Suzuki, Masayuki

    2007-01-01

    This paper presents an introduction to the development of software that provides a physiologic model of contrast medium enhancement by incorporating available physiologic data and contrast medium pharmacokinetics to predict an organ-specific aortic time-enhancement curve (TEC) in computed tomography (CT) with various contrast medium injection protocols in patients of various heights, weights, cardiac output levels, and so on. The physiologic model of contrast medium enhancement was composed of six compartments for early contrast enhancement pharmacokinetics. Contrast medium is injected via the antecubital vein and distributed to the right side of the heart, the pulmonary compartment, the left side of the heart, and the aorta. It then circulates back to the right side of the heart via the systemic circulation. A computer-based, compartmental model of the aortic system was generated using human physiologic parameters and six differential equations to describe the transport of contrast medium. Aortic TEC generated by the computer-based physiologic model of contrast medium enhancement showed validity and agreement with clinical data and findings published previously. A computer-based physiologic model that may help predict organ-specific CT contrast medium enhancement for different injection protocols was developed. Such a physiologic model may have multiple clinical applications. (author)

  9. Comparison of hand and semiautomatic tracing methods for creating maxillofacial artificial organs using sequences of computed tomography (CT) and cone beam computed tomography (CBCT) images.

    Science.gov (United States)

    Szabo, Bence T; Aksoy, Seçil; Repassy, Gabor; Csomo, Krisztian; Dobo-Nagy, Csaba; Orhan, Kaan

    2017-06-09

    The aim of this study was to compare the paranasal sinus volumes obtained by manual and semiautomatic imaging software programs using both CT and CBCT imaging. 121 computed tomography (CT) and 119 cone beam computed tomography (CBCT) examinations were selected from the databases of the authors' institutes. The Digital Imaging and Communications in Medicine (DICOM) images were imported into 3-dimensonal imaging software, in which hand mode and semiautomatic tracing methods were used to measure the volumes of both maxillary sinuses and the sphenoid sinus. The determined volumetric means were compared to previously published averages. Isometric CBCT-based volume determination results were closer to the real volume conditions, whereas the non-isometric CT-based volume measurements defined coherently lower volumes. By comparing the 2 volume measurement modes, the values gained from hand mode were closer to the literature data. Furthermore, CBCT-based image measurement results corresponded to the known averages. Our results suggest that CBCT images provide reliable volumetric information that can be depended on for artificial organ construction, and which may aid the guidance of the operator prior to or during the intervention.

  10. Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans

    Science.gov (United States)

    2017-07-13

    Computed Tomography Scans by Autumn R Kulaga, Kathryn L Loftis, and Eric Murray Approved for public release; distribution is...Army Research Laboratory Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans by Autumn R Kulaga...Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  11. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and

  12. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  13. X-ray Computed Tomography of Ultralightweight Metals

    National Research Council Canada - National Science Library

    Winter, John

    2001-01-01

    .... To date, the imaging capabilities of x-ray computed tomography have not been generally employed to nondestructively examine the internal structure of the products formed by these various processes...

  14. Automatic brain matter segmentation of computed tomography images using a statistical model: A tool to gain working time!

    Science.gov (United States)

    Bertè, Francesco; Lamponi, Giuseppe; Bramanti, Placido; Calabrò, Rocco S

    2015-10-01

    Brain computed tomography (CT) is useful diagnostic tool for the evaluation of several neurological disorders due to its accuracy, reliability, safety and wide availability. In this field, a potentially interesting research topic is the automatic segmentation and recognition of medical regions of interest (ROIs). Herein, we propose a novel automated method, based on the use of the active appearance model (AAM) for the segmentation of brain matter in CT images to assist radiologists in the evaluation of the images. The method described, that was applied to 54 CT images coming from a sample of outpatients affected by cognitive impairment, enabled us to obtain the generation of a model overlapping with the original image with quite good precision. Since CT neuroimaging is in widespread use for detecting neurological disease, including neurodegenerative conditions, the development of automated tools enabling technicians and physicians to reduce working time and reach a more accurate diagnosis is needed. © The Author(s) 2015.

  15. Computed tomography (CT) and diastematomyelia's diagnosis

    International Nuclear Information System (INIS)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S.; Barros, A.P. de

    1982-01-01

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized. (Author) [pt

  16. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...

  17. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  18. Optical computed tomography for imaging the breast: first look

    Science.gov (United States)

    Grable, Richard J.; Ponder, Steven L.; Gkanatsios, Nikolaos A.; Dieckmann, William; Olivier, Patrick F.; Wake, Robert H.; Zeng, Yueping

    2000-07-01

    The purpose of the study is to compare computed tomography optical imaging with traditional breast imaging techniques. Images produced by computed tomography laser mammography (CTLMTM) scanner are compared with images obtained from mammography, and in some cases ultrasound and/or magnetic resonance imaging (MRI). During the CTLM procedure, a near infrared laser irradiates the breast and an array of photodiodes detectors records light scattered through the breast tissue. The laser and detectors rotate synchronously around the breast to acquire a series of slice data along the coronal place. The procedure is performed without any breast compression or optical matching fluid. Cross-sectional slices of the breast are produced using a reconstruction algorithm. Reconstruction based on the diffusion theory is used to produce cross-sectional slices of the breast. Multiple slice images are combined to produce a three dimensional volumetric array of the imaged breast. This array is used to derive axial and sagittal images of the breast corresponding to cranio-caudal and medio-lateral images used in mammography. Over 200 women and 3 men have been scanned in clinical trials. The most obvious features seen in images produced by the optical tomography scanner are vascularization and significant lesions. Breast features caused by fibrocystic changes and cysts are less obvious. Breast density does not appear to be a significant factor in the quality of the image. We see correlation of the optical image structure with that seen with traditional breast imaging techniques. Further testing is being conducted to explore the sensitivity and specificity of optical tomography of the breast.

  19. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  20. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  1. Computer stress study of bone with computed tomography

    International Nuclear Information System (INIS)

    Linden, M.J.; Marom, S.A.; Linden, C.N.

    1986-01-01

    A computer processing tool has been developed which, together with a finite element program, determines the stress-deformation pattern in a long bone, utilizing Computed Tomography (CT) data files for the geometry and radiographic density information. The geometry, together with mechanical properties and boundary conditions: loads and displacements, comprise the input of the Finite element (FE) computer program. The output of the program is the stresses and deformations in the bone. The processor is capable of developing an accurate three-dimensional finite element model from a scanned human long bone due to the CT high pixel resolution and the local mechanical properties determined from the radiographic densities of the scanned bone. The processor, together with the finite element program, serves first as an analysis tool towards improved understanding of bone function and remodelling. In this first stage, actual long bones may be scanned and analyzed under applied loads and displacements, determined from existing gait analyses. The stress-deformation patterns thus obtained may be used for studying the biomechanical behavior of particular long bones such as bones with implants and with osteoporosis. As a second stage, this processor may serve as a diagnostic tool for analyzing the biomechanical response of a specific patient's long long bone under applied loading by utilizing a CT data file of the specific bone as an input to the processor with the FE program

  2. Comparison of Swedish and Norwegian Use of Cone-Beam Computed Tomography: a Questionnaire Study

    Directory of Open Access Journals (Sweden)

    Jerker Edén Strindberg

    2015-12-01

    Full Text Available Objectives: Cone-beam computed tomography in dentistry can be used in some countries by other dentists than specialists in radiology. The frequency of buying cone-beam computed tomography to examine patients is rapidly growing, thus knowledge of how to use it is very important. The aim was to compare the outcome of an investigation on the use of cone-beam computed tomography in Sweden with a previous Norwegian study, regarding specifically technical aspects. Material and Methods: The questionnaire contained 45 questions, including 35 comparable questions to Norwegian clinics one year previous. Results were based on inter-comparison of the outcome from each of the two questionnaire studies. Results: Responses rate was 71% in Sweden. There, most of cone-beam computed tomography (CBCT examinations performed by dental nurses, while in Norway by specialists. More than two-thirds of the CBCT units had a scout image function, regularly used in both Sweden (79% and Norway (75%. In Sweden 4% and in Norway 41% of the respondents did not wait for the report from the radiographic specialist before initiating treatment. Conclusions: The bilateral comparison showed an overall similarity between the two countries. The survey gave explicit and important knowledge of the need for education and training of the whole team, since radiation dose to the patient could vary a lot for the same kind of radiographic examination. It is essential to establish quality assurance protocols with defined responsibilities in the team in order to maintain high diagnostic accuracy for all examinations when using cone-beam computed tomography for patient examinations.

  3. Computed tomography in space-occupying intraspinal processes

    International Nuclear Information System (INIS)

    Proemper, C.; Friedmann, G.

    1983-01-01

    Spinal computed tomography has considerably enhanced differential diagnostic safety in the course of the past two years. It has disclosed new possibilities of indication in the diagnosis of the vertebral column. With the expected improvement in apparatus technology, computed tomography will increasingly replace invasive examination methods. Detailed knowledge of clinical data, classification of the neurological findings, and localisation of the height - as far as possible - are the necessary prerequisites of successful diagnosis. If they are absent, it is recommended to perform myelography followed by secondary CT-myelography. If these preliminary conditions are observed, spinal CT can make outstanding contributions to be diagnosis of slipped disk, of the constricted vertebral canal, as well as tumours, malformations and posttraumatic conditions, postoperative changes and inflammatory processes. (orig.) [de

  4. Soil structure changes evaluated with computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz Fernando

    2010-01-01

    The objective of this work was to evaluate in millimetric scale changes in soil bulk density and porosity, using the gamma-ray computed tomography in soil samples with disturbed structure due to wetting and drying (W-D) cycles. Soil samples with 98.1 cm 3 were sieved using a 2 mm mesh and homogeneously packed in PVC cylinders. Soil samples were submitted to 1, 2, and 3 W-D cycles. Control samples were not submitted to W-D cycles. After repetitions of W-D cycles, soil sample porosity decreased and soil layers became denser. Computed tomography allowed a continuous analysis of soil bulk density and also soil porosity along millimetric (0.08 cm) layers, what cannot be provided by traditional methods used in soil physics. (author)

  5. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  6. Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography.

    Science.gov (United States)

    Benz, Robyn Melanie; Garcia, Meritxell Alzamora; Amsler, Felix; Voigt, Johannes; Fieselmann, Andreas; Falkowski, Anna Lucja; Stieltjes, Bram; Hirschmann, Anna

    2018-01-01

    Phantom-based initial performance assessment of a prototype three-dimensional (3-D) x-ray system and comparison of 3-D tomography with computed tomography (CT) were proposed. A 3-D image quality phantom was scanned with a prototype version of 3-D cone-beam CT imaging implemented on a twin robotic x-ray system using three trajectories (163 deg = table, 188 deg = upright, and 200 deg = side), six tube voltages (60, 70, 81, 90, 100, and 121 kV), and four detector doses (0.348, 0.696, 1.740, and [Formula: see text]). CT was obtained with a clinical protocol. Spatial resolution (line pairs/cm) and soft-tissue-contrast resolution were assessed by two independent readers. Radiation dose was assessed. Descriptive and analysis of variance (ANOVA) ([Formula: see text]) were performed. With 3-D tomography, a maximum of 16 lp/cm was visible and best soft-tissue-contrast resolution was 2 mm at 30 Hounsfield units (HU) for 160 projections. With CT, 10 lp/cm was visible and soft-tissue-contrast resolution was 4 mm at 20 HU. The upright trajectory yielded significantly better spatial resolution and soft tissue contrast, and the side trajectory yielded significantly higher soft tissue contrast than the table trajectory ([Formula: see text]). Radiation dose was higher in 3-D tomography (45 to 704 mGycm) than CT (44 mGycm). Three-dimensional tomography renders overall equal or higher spatial resolution and comparable soft tissue contrast to CT for medium- and high-dose protocols in the side and upright trajectories, but with higher radiation doses.

  7. Computed tomography in orbital fractures and optic nerve trauma

    International Nuclear Information System (INIS)

    Dietrich, U.; Sievers, K.; Feldges, A.; Nau, H.E.

    1990-01-01

    Ten patients with orbital fractures and optic nerve trauma are reported. Fractures of the optic canal could be demonstrated by computed tomography in six cases and fractures of the orbital apex in another three cases. Surgical decompression of the optic canal was performed in seven cases. Computed tomography enhanced decision for surgery in cases of intraorbital haematoma with exophthalmus and narrowing of the canal by bony fragments, especially in those patients presenting with incomplete or progressive visual disturbance. (orig.) [de

  8. Three Dimensional Digital Sieving of Asphalt Mixture Based on X-ray Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chichun Hu

    2017-07-01

    Full Text Available In order to perform three-dimensional digital sieving based on X-ray computed tomography images, the definition of digital sieve size (DSS was proposed, which was defined as the minimum length of the minimum bounding squares of all possible orthographic projections of an aggregate. The corresponding program was developed to reconstruct aggregate structure and to obtain DSS. Laboratory experiments consisting of epoxy-filled aggregate specimens were conducted to investigate the difference between mechanical sieve analysis and the digital sieving technique. It was suggested that concave surface of aggregate was the possible reason for the disparity between DSS and mechanical sieve size. A comparison between DSS and equivalent diameter was also performed. Moreover, the digital sieving technique was adopted to evaluate the gradation of stone mastic asphalt mixtures. The results showed that the closest proximity of the laboratory gradation curve was achieved by calibrated DSS, among gradation curves based on calibrated DSS, un-calibrated DSS and equivalent diameter.

  9. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-01-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  10. Pediatrics patient in computed tomography: risk awareness among medical staff

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Kosutic, D.; Lazarevic, Dj.

    2009-01-01

    In this paper the results of investigation about risk awareness in pediatrics computed tomography among medical staff are presented. Questionnaires were distributed along seven hospitals, 84 people were enrolled in this investigation. The results showed awareness of the potential risks associated with ionizing radiation in computed tomography. However, there is still widespread underestimation of relative doses and risks in case of pediatric patients. (author) [sr

  11. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  12. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  13. Positron computed tomography with fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Hervouet, T.; Kraeber-Bodere, F.; Lamy, T.; Le Gouil, S.; Devillers, A.; Bodet-Milin, C.; Ansquer, C.; Cheze-le Rest, C.; Metges, J.P.; Teyton, P.; Lozach, P.; Volant, A.; Bizais, Y.; Visvikis, D.; Morel, O.; Girault, S.; Soulie, P.; Dupoiron, D.; Berthelot, C.; Lorimier, G.; Jallet, P.; Garin, E.; Prigent, F.; Lesimple, T.; Barge, M.L.; Rousseau, C.; Devillers, A.; Bernard, A.M.; Bouriel, C.; Bridji, B.; Resche, R.; Banayan, S.; Claret, M.; Ninet, J.; Janier, M.; Billotey, C.; Garin, E.; Devillers, A.; Becker, S.; Lecloirec, J.; Boucher, E.; Raoul, J.L.; Rolland, V.; Oudoux, A.; Valette, F.; Dupas, B.; Moreau, P.; Champion, L.; Anract, P.; Wartski, M.; Laurence, V.; Goldwasser, F.; Pecking, A.P.; Alberini, J.L.; Brillouet, S.; Caselles, O.; Allal, B.; Zerdoud, S.; Gansel, M.G.; Thomas, F.; Dierrickx, L.; Delord, J.P.; Marchand, C.; Resche, I.; Mahe, M.A.

    2006-01-01

    Several oral communications present the interest of positron computed tomography with fluorodeoxyglucose in the detection of cancers, or for the follow up of cancers treatments in order to detect early possible relapses.PET FDG is also used to optimize the definition of target volume in order to avoid side effects and to get a better control of the illness. (N.C.)

  14. Stereo-tomography in triangulated models

    Science.gov (United States)

    Yang, Kai; Shao, Wei-Dong; Xing, Feng-yuan; Xiong, Kai

    2018-04-01

    Stereo-tomography is a distinctive tomographic method. It is capable of estimating the scatterer position, the local dip of scatterer and the background velocity simultaneously. Building a geologically consistent velocity model is always appealing for applied and earthquake seismologists. Differing from the previous work to incorporate various regularization techniques into the cost function of stereo-tomography, we think extending stereo-tomography to the triangulated model will be the most straightforward way to achieve this goal. In this paper, we provided all the Fréchet derivatives of stereo-tomographic data components with respect to model components for slowness-squared triangulated model (or sloth model) in 2D Cartesian coordinate based on the ray perturbation theory for interfaces. A sloth model representation means a sparser model representation when compared with conventional B-spline model representation. A sparser model representation leads to a smaller scale of stereo-tomographic (Fréchet) matrix, a higher-accuracy solution when solving linear equations, a faster convergence rate and a lower requirement for quantity of data space. Moreover, a quantitative representation of interface strengthens the relationships among different model components, which makes the cross regularizations among these model components, such as node coordinates, scatterer coordinates and scattering angles, etc., more straightforward and easier to be implemented. The sensitivity analysis, the model resolution matrix analysis and a series of synthetic data examples demonstrate the correctness of the Fréchet derivatives, the applicability of the regularization terms and the robustness of the stereo-tomography in triangulated model. It provides a solid theoretical foundation for the real applications in the future.

  15. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  16. Positron computed tomography: current state, clinical results and future trends

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  17. Prognostic Evaluation of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Endometrial Cancer

    DEFF Research Database (Denmark)

    Vilstrup, Mie Holm; Jochumsen, Kirsten M; Hess, Søren

    2017-01-01

    .19-8.49) and 1.93 (0.80-4.68), respectively. Whole-body cTLG of greater than or equal to 176.1 g yielded a hazard ratio of 5.70 (1.94-16.78) for OS in a multivariate analysis. CONCLUSIONS: Preoperative SUVmax and cTLG showed potential as independent prognostic markers of OS in patients with primarily high...... and a preoperative F-fluorodeoxyglucose positron emission tomography/computed tomography before curatively intended treatment were included. The scans were evaluated using standard uptake values [maximum standard uptake value (SUVmax) and partial volume corrected (c) mean standardized uptake value (SUVmean...... proportional regression models were used for prognostic evaluation. RESULTS: Eighty-three patients (median age, 69.9 y; range, 26.8-91.1) with primarily high-risk endometrial cancer or suspected high The International Federation of Gynecology and Obstetrics stage were included. Mean follow-up time was 3...

  18. Comparison of helical computed tomography and ultrasonography in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Nafees, M.; Abbas, G.; Sarwar, S.

    2010-01-01

    The objective of study is to compare the diagnostic accuracy of helical computed tomography and ultrasonography in acute appendicitis using histopathology as gold standard. Thirty cases of clinically suspected acute appendicitis were included in the study selected on non probability convenience sampling technique. Computed tomography and graded compression ultrasonography of right lower quadrant of abdomen were conducted and results compared with histopathological findings. Amongst 30 patients who underwent computed tomography and graded compression ultrasonography examinations of right lower quadrant for diagnosis of acute appendicitis, on computed tomography 19 were diagnosed with acute appendicitis, 10 were diagnosed as not having the disease and 01 patient diagnosed as not having appendicitis on computed tomography did not improve clinically, was operated upon and histopathology proved it as acute appendicitis. While on graded compression ultrasonography 15 were diagnosed with acute appendicitis, 11 were diagnosed as not having the disease and 04 patients diagnosed as not having appendicitis on ultrasonography, did not improve clinically, were operated upon and histopathology proved it as acute appendicitis. This showed that CT scan has sensitivity of 95%, specificity 100%, positive predictive value 100%, negative predictive value 90.91% and overall accuracy of 96.67% while ultrasonography has sensitivity of 78.9%, specificity 100%, positive predictive value 100%, negative predictive value 73.33% and overall accuracy of 86.67%. We concluded that Helical computed tomography is highly accurate in diagnosing acute appendicitis as compared to ultrasonography and it helps to reduce negative appendectomy rate. (author)

  19. Computed tomography of the iliopsoas muscle

    International Nuclear Information System (INIS)

    Nino-Murcia, M.; Wechsler, R.J.; Brennan, R.E.

    1983-01-01

    Computed tomography (CT) is an ideal method for the imaging of the psoas muscle. The authors present 13 cases of patients with psoas abnormalities diagnosed by CT. The CT features of the different pathologic entities and comparison of CT with other imaging modalities are discussed. (orig.)

  20. Electronic cleansing for computed tomography (CT) colonography using a scale-invariant three-material model

    NARCIS (Netherlands)

    Serlie, Iwo W. O.; Vos, Frans M.; Truyen, Roel; Post, Frits H.; Stoker, Jaap; van Vliet, Lucas J.

    2010-01-01

    A well-known reading pitfall in computed tomography (CT) colonography is posed by artifacts at T-junctions, i.e., locations where air-fluid levels interface with the colon wall. This paper presents a scale-invariant method to determine material fractions in voxels near such T-junctions. The proposed

  1. Computed tomography scanner applied to soil compaction studies

    International Nuclear Information System (INIS)

    Vaz, C.M.P.

    1989-11-01

    The soil compaction problem was studied using a first generation computed tomography scanner (CT). This apparatus gets images of soil cross sections samples, with resolution of a few millimeters. We performed the following laboratory and field experiments: basic experiments of equipment calibrations and resolutions studies; measurements of compacted soil thin layers; measurements of soil compaction caused by agricultural tools; stress-strain modelling in confined soil sample, with several moisture degree; characterizations of soil bulk density profile with samples collected in a hole (trench), comparing with a cone penetrometer technique. (author)

  2. [Cardiac computed tomography: new applications of an evolving technique].

    Science.gov (United States)

    Martín, María; Corros, Cecilia; Calvo, Juan; Mesa, Alicia; García-Campos, Ana; Rodríguez, María Luisa; Barreiro, Manuel; Rozado, José; Colunga, Santiago; de la Hera, Jesús M; Morís, César; Luyando, Luis H

    2015-01-01

    During the last years we have witnessed an increasing development of imaging techniques applied in Cardiology. Among them, cardiac computed tomography is an emerging and evolving technique. With the current possibility of very low radiation studies, the applications have expanded and go further coronariography In the present article we review the technical developments of cardiac computed tomography and its new applications. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  3. Cone Beam X-ray Luminescence Computed Tomography Based on Bayesian Method.

    Science.gov (United States)

    Zhang, Guanglei; Liu, Fei; Liu, Jie; Luo, Jianwen; Xie, Yaoqin; Bai, Jing; Xing, Lei

    2017-01-01

    X-ray luminescence computed tomography (XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. Combining the principles of X-ray excitation of luminescence-based probes and optical signal detection, XLCT naturally fuses functional and anatomical images and provides complementary information for a wide range of applications in biomedical research. In order to improve the data acquisition efficiency of previously developed narrow-beam XLCT, a cone beam XLCT (CB-XLCT) mode is adopted here to take advantage of the useful geometric features of cone beam excitation. Practically, a major hurdle in using cone beam X-ray for XLCT is that the inverse problem here is seriously ill-conditioned, hindering us to achieve good image quality. In this paper, we propose a novel Bayesian method to tackle the bottleneck in CB-XLCT reconstruction. The method utilizes a local regularization strategy based on Gaussian Markov random field to mitigate the ill-conditioness of CB-XLCT. An alternating optimization scheme is then used to automatically calculate all the unknown hyperparameters while an iterative coordinate descent algorithm is adopted to reconstruct the image with a voxel-based closed-form solution. Results of numerical simulations and mouse experiments show that the self-adaptive Bayesian method significantly improves the CB-XLCT image quality as compared with conventional methods.

  4. [Axial computer tomography of the neurocranium (author's transl)].

    Science.gov (United States)

    Stöppler, L

    1977-05-27

    Computer tomography (CT), a new radiographic examination technique, is very highly efficient, for it has high informative content with little stress for the patient. In contrast to the conventional X-ray technology, CT succeeds, by direct presentation of the structure of the soft parts, in obtaining information which comes close to that of macroscopic neuropathology. The capacity and limitations of the method at the present stage of development are reported. Computer tomography cannot displace conventional neuroradiological methods of investigation, although it is rightly presented as a screening method and helps towards selective use. Indications, technical integration and handling of CT are prerequisites for the exhaustive benefit of the excellent new technique.

  5. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest...

  6. Magnetic resonance tomography and computed tomography of the brain for diagnosing Wilson's disease

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Straube, A.; Beyer, H.K.; Leopold, H.C.

    1985-01-01

    The authors report on two woman patients with confirmed Wilson's desease (hepatolenticular degeneration) who had neurological deficits and showed typical changes evident from laboratory data. Both computed tomography and magnetic resonance tomography revealed degenerative changes in the basal ganglia, especially of the lenticular nucleus, MR showing these defects more clearly than CT. There was a noticeable symmetrical enhancement of signals in the lenticular nucleus which was particularly evident on the image basing on the T 2 (spin-spin relaxation time constant) values. MR could be superior to CT with regard to showing up pathological changes in the basal ganglia. The future indication of MR could be the establishment of an exact correlation between clinical signs and symptoms on the one hand, and morphological findings on the other. Over and above this, it should be explored to what extent MR can already detect degenerative changes in the brain in primarily hepatic types of the disease even without prior neurological examination. (orig.) [de

  7. Creating vascular models by postprocessing computed tomography angiography images: a guide for anatomical education.

    Science.gov (United States)

    Govsa, Figen; Ozer, Mehmet Asim; Sirinturk, Suzan; Eraslan, Cenk; Alagoz, Ahmet Kemal

    2017-08-01

    A new application of teaching anatomy includes the use of computed tomography angiography (CTA) images to create clinically relevant three-dimensional (3D) printed models. The purpose of this article is to review recent innovations on the process and the application of 3D printed models as a tool for using under and post-graduate medical education. Images of aortic arch pattern received by CTA were converted into 3D images using the Google SketchUp free software and were saved in stereolithography format. Using a 3D printer (Makerbot), a model mode polylactic acid material was printed. A two-vessel left aortic arch was identified consisting of the brachiocephalic trunk and left subclavian artery. The life-like 3D models were rotated 360° in all axes in hand. The early adopters in education and clinical practices have embraced the medical imaging-guided 3D printed anatomical models for their ability to provide tactile feedback and a superior appreciation of visuospatial relationship between the anatomical structures. Printed vascular models are used to assist in preoperative planning, develop intraoperative guidance tools, and to teach patients surgical trainees in surgical practice.

  8. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...

  9. Analysis of intensity variability in multislice and cone beam computed tomography.

    Science.gov (United States)

    Nackaerts, Olivia; Maes, Frederik; Yan, Hua; Couto Souza, Paulo; Pauwels, Ruben; Jacobs, Reinhilde

    2011-08-01

    The aim of this study was to evaluate the variability of intensity values in cone beam computed tomography (CBCT) imaging compared with multislice computed tomography Hounsfield units (MSCT HU) in order to assess the reliability of density assessments using CBCT images. A quality control phantom was scanned with an MSCT scanner and five CBCT scanners. In one CBCT scanner, the phantom was scanned repeatedly in the same and in different positions. Images were analyzed using registration to a mathematical model. MSCT images were used as a reference. Density profiles of MSCT showed stable HU values, whereas in CBCT imaging the intensity values were variable over the profile. Repositioning of the phantom resulted in large fluctuations in intensity values. The use of intensity values in CBCT images is not reliable, because the values are influenced by device, imaging parameters and positioning. © 2011 John Wiley & Sons A/S.

  10. Fourier-based approach to interpolation in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2001-01-01

    It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal direction and because the exploitation of the redundancy of fanbeam data acquired over 360 degree sign to generate additional longitudinal samples does not automatically eliminate the aliasing. In this paper we demonstrate that for pitches near 1 or lower, the redundant fanbeam data, when used properly, can provide sufficient information to satisfy a generalized sampling theorem and thus to eliminate aliasing. We develop and evaluate a Fourier-based algorithm, called 180FT, that accomplishes this. As background we present a second Fourier-based approach, called 360FT, that makes use only of the directly measured data. Both Fourier-based approaches exploit the fast Fourier transform and the Fourier shift theorem to generate from the helical projection data a set of fanbeam sinograms corresponding to equispaced transverse slices. Slice-by-slice reconstruction is then performed by use of two-dimensional fanbeam algorithms. The proposed approaches are compared to their counterparts based on the use of linear interpolation - the 360LI and 180LI approaches. The aliasing suppression property of the 180FT approach is a clear advantage of the approach and represents a step toward the desirable goal of achieving uniform longitudinal resolution properties in reconstructed helical CT volumes

  11. Computer-aided classification of lung nodules on computed tomography images via deep learning technique

    Directory of Open Access Journals (Sweden)

    Hua KL

    2015-08-01

    Full Text Available Kai-Lung Hua,1 Che-Hao Hsu,1 Shintami Chusnul Hidayati,1 Wen-Huang Cheng,2 Yu-Jen Chen3 1Department of Computer Science and Information Engineering, National Taiwan University of Science and Technology, 2Research Center for Information Technology Innovation, Academia Sinica, 3Department of Radiation Oncology, MacKay Memorial Hospital, Taipei, Taiwan Abstract: Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain. Keywords: nodule classification, deep learning, deep belief network, convolutional neural network

  12. A true minimally invasive approach for cochlear implantation: high accuracy in cranial base navigation through flat-panel-based volume computed tomography.

    Science.gov (United States)

    Majdani, Omid; Bartling, Soenke H; Leinung, Martin; Stöver, Timo; Lenarz, Minoo; Dullin, Christian; Lenarz, Thomas

    2008-02-01

    High-precision intraoperative navigation using high-resolution flat-panel volume computed tomography makes feasible the possibility of minimally invasive cochlear implant surgery, including cochleostomy. Conventional cochlear implant surgery is typically performed via mastoidectomy with facial recess to identify and avoid damage to vital anatomic landmarks. To accomplish this procedure via a minimally invasive approach--without performing mastoidectomy--in a precise fashion, image-guided technology is necessary. With such an approach, surgical time and expertise may be reduced, and hearing preservation may be improved. Flat-panel volume computed tomography was used to scan 4 human temporal bones. A drilling channel was planned preoperatively from the mastoid surface to the round window niche, providing a margin of safety to all functional important structures (e.g., facial nerve, chorda tympani, incus). Postoperatively, computed tomographic imaging and conventional surgical exploration of the drilled route to the cochlea were performed. All 4 specimens showed a cochleostomy located at the scala tympani anterior inferior to the round window. The chorda tympani was damaged in 1 specimen--this was preoperatively planned as a narrow facial recess was encountered. Using flat-panel volume computed tomography for image-guided surgical navigation, we were able to perform minimally invasive cochlear implant surgery defined as a narrow, single-channel mastoidotomy with cochleostomy. Although this finding is preliminary, it is technologically achievable.

  13. Asymmetrically increased rib cage uptake on bone scintigraphy: Incidental detection of pleural mesothelioma on single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Dhull, Varun Singh; Sharma, Punit; Durgapal, Prashant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Follow-up bone scintigraphy (BS) in a patient of carcinoma left breast, who was treated with surgery followed by radiotherapy 12 years back, revealed asymmetrically increased radiotracer uptake in left-sided ribs. Since, this pattern was atypical for metastatic rib involvement, single photon emission computed tomography/computed tomography (SPECT/CT) of thorax was done in the same setting which revealed circumferential nodular left-sided pleural thickening. Biopsy confirmed it to be pleural mesothelioma. Left-sided ribs showed no abnormality on CT, thus suggesting the rib uptake as reactive in nature. This pattern of asymmetric rib uptake on BS should be kept in mind and warrants further investigation for determining underlying pathology

  14. Computed tomography evaluation of autogenous graft in sinus lift surgery

    International Nuclear Information System (INIS)

    Ajzen, Sergio Aron; Moscatiello, Rafael Andrade; Lima, Aida Maria Custodio de; Moscatiello, Vitoria Aparecida Muglia; Helio Kiitiro Yamashita; Mosacatiello, Rafael Muglia; Nishiguchi, Celso Itiro; Alves, Maria Teresa de Seixas

    2001-01-01

    The objective was to quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from apheresis or centrifugation using computed tomography. This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months), with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by apheresis. The results showed that computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. It was concluded that clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants. (author)

  15. The study of radiographic technique with low exposure using computed panoramic tomography

    International Nuclear Information System (INIS)

    Saito, Yasuhiro

    1987-01-01

    A new imaging system for the dental field that combines recent advances in both the electronics and computer technologies was developed. This new imaging system is a computed panoramic tomography process based on the newly developed laser-scan system. In this study a quantitative image evaluation was performed comparing anatomical landmark in computed panoramic tomography at a low exposure (LPT) and in conventional panoramic tomography at a routin (CPT), and the following results were obtained: 1. The diagnostic value of the CPT decreased with decreasing exposure, paticularly with regard to the normal anatomical landmarks of such microstructural parts as the periodontal space, lamina dura and the enamel-dentin border. 2. The LPT was highly diagnostic value for all normal anatomical landmark, averaging about twice as valuable diagnostically as CPT. 3. The visually diagnostic value of the periodontal space, lamina dura, enamel-dentin border and the anatomical morphology of the teeth on the LPT beeing slightly dependent on the spatial frequency enhancement rank. 4. The LPT formed images with almost the same range of density as the CPT. 5. Computed panoramic tomographs taken at a low exposure revealed more information of the trabecular bone pattern on the image than conventional panoramic tomographs taken under routine condition in the visual spatial frequency range (0.1 - 5.0 cycle/mm). (author) 67 refs

  16. Computed tomography assessment of early response to neoadjuvant therapy in colon cancer

    DEFF Research Database (Denmark)

    Dam, Claus; Lund-Rasmussen, Vera; Pløen, John

    2015-01-01

    INTRODUCTION: Using multidetector computed tomography, we aimed to assess the early response of neoadjuvant drug therapy for locally advanced colon cancer. METHODS: Computed tomography with IV contrast was acquired from 67 patients before and after up to three cycles of preoperative treatment. All...

  17. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  18. Cone beam computed tomography: basics and applications in dentistry.

    Science.gov (United States)

    Venkatesh, Elluru; Elluru, Snehal Venkatesh

    2017-01-01

    The introduction of cone beam computed tomography (CBCT) devices, changed the way oral and maxillofacial radiology is practiced. CBCT was embraced into the dental settings very rapidly due to its compact size, low cost, low ionizing radiation exposure when compared to medical computed tomography. Alike medical CT, 3 dimensional evaluation of the maxillofacial region with minimal distortion is offered by the CBCT. This article provides an overview of basics of CBCT technology and reviews the specific application of CBCT technology to oral and maxillofacial region with few illustrations.

  19. Study on Sintering Mechanism of Stainless Steel Fiber Felts by X-ray Computed Tomography

    Directory of Open Access Journals (Sweden)

    Jun Ma

    2016-01-01

    Full Text Available The microstructure evolution of Fe-17 wt. % Cr-12 wt. % Ni-2 wt. % Mo stainless steel fiber felts during the fast sintering process was investigated by the synchrotron radiation X-ray computed tomography technique. The equation of dynamics of stable inter-fiber neck growth was established for the first time based on the geometry model of sintering joints of two fibers and Kucsynski’s two-sphere model. The specific evolutions of different kinds of sintering joints were observed in the three-dimensional images. The sintering mechanisms during sintering were proposed as plastic flow and grain boundary diffusion, the former leading to a quick growth of sintering joints.

  20. Computed tomography and plain radiography in experimental fracture healing

    International Nuclear Information System (INIS)

    Braunstein, E.M.; Goldstein, S.A.; Ku, J.; Smith, P.; Matthews, L.S.

    1986-01-01

    We evaluated the relative contribution of plain radiographs and computed tomography to the assessment of fracture healing under experimental circumstances. In 15 sheep, we performed midshaft femoral osteotomies and internal fixation of the resultant segmental fractures. Radiographs were obtained preoperatively and immediately postoperatively. Animals were sacrificed at 3 weeks, 6 weeks, 12 weeks, 24 weeks, and 36 weeks after surgery, and the femoral specimens radiographed. After removal of the internal fixation devices, computed tomographic scans of the specimens were performed. Computed tomography may be of value in the evaluation of fractures of long bones in those cases in which clinical examination and plain radiographs fail to give adequate information as to the status of healing. (orig./SHA)

  1. Development of industrial x-ray computed tomography and its application to refractories

    International Nuclear Information System (INIS)

    Aiba, Yoshiro; Oki, Kazuo; Nakamura, Shigeo; Fujii, Masashi.

    1985-01-01

    An industrial X-ray computed tomography was developed under the influence of the rapid spread of the use of the X-ray CT scanner in the medical field and improvements of the equipment. Although current nondestructive testing machines of refractories use the ultrasonic inspection method or the X-ray fluoroscopic method, these equipments cannot produce a tomogram or cannot carry out quantitative evaluation. By using an industrial X-ray computed tomography, submerged nozzles for continuous casting of steel were analyzed with interesting results. The features of the industrial X-ray computed tomography applied for refractory nozzles are as follows: (1) It promptly detects interior defects. (2) It can measure dimensions and shapes. (3) It can numerically express the distribution of density. Accordingly, it is expected that the industrial X-ray computed tomography will widely be used in the fields of development and quality control of refractories and advanced ceramic materials. (author)

  2. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  3. Is there any role of positron emission tomography computed tomography for predicting resectability of gallbladder cancer?

    Science.gov (United States)

    Kim, Jaihwan; Ryu, Ji Kon; Kim, Chulhan; Paeng, Jin Chul; Kim, Yong-Tae

    2014-05-01

    The role of integrated (18)F-2-fluoro-2-deoxy-D-glucose positron emission tomography computed tomography (PET-CT) is uncertain in gallbladder cancer. The aim of this study was to show the role of PET-CT in gallbladder cancer patients. Fifty-three patients with gallbladder cancer underwent preoperative computed tomography (CT) and PET-CT scans. Their medical records were retrospectively reviewed. Twenty-six patients underwent resection. Based on the final outcomes, PET-CT was in good agreement (0.61 to 0.80) with resectability whereas CT was in acceptable agreement (0.41 to 0.60) with resectability. When the diagnostic accuracy of the predictions for resectability was calculated with the ROC curve, the accuracy of PET-CT was higher than that of CT in patients who underwent surgical resection (P=0.03), however, there was no difference with all patients (P=0.12). CT and PET-CT had a discrepancy in assessing curative resection in nine patients. These consisted of two false negative and four false positive CT results (11.3%) and three false negative PET-CT results (5.1%). PET-CT was in good agreement with the final outcomes compared to CT. As a complementary role of PEC-CT to CT, PET-CT tended to show better prediction about resectability than CT, especially due to unexpected distant metastasis.

  4. The influence of computer tomography on radiological diagnostics of malignant tumors

    International Nuclear Information System (INIS)

    Gerhardt, P.; Glueck, E.; Siems, H.

    1981-01-01

    A survey is presented of the present status of cancer diagnostics in the following organs and organ systems: neurocranium, visceral cranium and base of skull, larynx and thyroid, thorax, pancreas, retroperitoneum, kidneys and adrenal glands, pelvis, and skeletal system. The rank of computer tomography is compared with those of other examination techniques. (HT) [de

  5. Identification of a unique cause of ring artifact seen in computed tomography trans-axial images

    International Nuclear Information System (INIS)

    Jha, Ashish Kumar; Purandare, Nilendu C; Shah, Sneha; Agrawal, Archi; Puranik, Ameya D; Rangarajan, Venkatesh

    2013-01-01

    Artifacts present in computed tomography (CT) image often degrade the image quality and ultimately, the diagnostic outcome. Ring artifact in trans-axial image is caused by either miscalibrated or defective detector element of detector row, which is often categorized as scanner based artifact. A ring artifact detected on trans-axial CT image of positron emission tomography/computed tomography (PET/CT), was caused by contamination of CT tube aperture by droplet of injectable contrast medium. This artifact was corrected by removal of contrast droplet from CT tube aperture. The ring artifact is a very common artifact, commonly cited in the literature. Our case puts forward an uncommon cause of this artifact and its method of correction, which also, has no mention in the existing literature

  6. Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.

    Science.gov (United States)

    Sano, Atsushi

    2018-05-01

     The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography.  Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window.  In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case.  In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.

  7. Pulmonary artery aneurysm in Bechcet's disease: helical computed tomography study

    International Nuclear Information System (INIS)

    Munoz, J.; Caballero, P.; Olivera, M. J.; Cajal, M. L.; Caniego, J. L.

    2000-01-01

    Behcet's disease is a vasculitis of unknown etiology that affects arteries and veins of different sizes and can be associated with pulmonary artery aneurysms. We report the case of a patient with Behcet's disease and a pulmonary artery aneurysm who was studied by means of plain chest X ray, helical computed tomography and pulmonary arteriography. Helical computed tomography is a reliable technique for the diagnosis and follow-up of these patients. (Author) 9 refs

  8. Advances in equine computed tomography and use of contrast media.

    Science.gov (United States)

    Puchalski, Sarah M

    2012-12-01

    Advances in equine computed tomography have been made as a result of improvements in software and hardware and an increasing body of knowledge. Contrast media can be administered intravascularly or intrathecally. Contrast media is useful to differentiate between tissues of similar density. Equine computed tomography can be used for many different clinical conditions, including lameness diagnosis, fracture identification and characterization, preoperative planning, and characterization of skull diseases. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    Romero, J.A.; Kim, E.E.; Tresukosol, D.; Kudelka, A.P.; Edwards, C.L.; Kavanagh, J.J.

    1995-01-01

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  10. Motion artifacts in computed tomography

    International Nuclear Information System (INIS)

    Yang, C.K.

    1979-01-01

    In the year 1972, the first Computed Tomography Scanner (or CT) was introduced and caused a revolution in the field of Diagnostic Radiology. A tomogram is a cross-sectional image of a three-dimensional object obtained through non-invasive measurements. The image that is presented is very similar to what would be seen if a thin cross-sectional slice of the patient was examined. In Computed Tomography, x-rays are passed through the body of a patient in many different directions and their attenuation is detected. By using some mathematical theorems, the attenuation information can be converted into the density of the patient along the x-ray path. Combined with modern sophisticated computer signal processing technology, a cross-sectional image can be generated and displayed on a TV monitor. Usually a good CT image relies on the patient not moving during the x-ray scanning. However, for some unconscious or severely ill patients, this is very difficult to achieve. Thus, the motion during the scan causes the so-called motion artifacts which distort the displayed image and sometimes these motion artifacts make diagnosis impossible. Today, to remove or avoid motion artifacts is one of the major efforts in developing new scanner systems. In this thesis, a better understanding of the motion artifacts problem in CT scaning is gained through computer simulations, real scanner experiments and theoretical analyses. The methods by which the distorted image can be improved are simulated also. In particular, it is assumed that perfect knowledge of the patient motion is known since this represents the theoretical limit on how well the distorted image can be improved

  11. Projection model for flame chemiluminescence tomography based on lens imaging

    Science.gov (United States)

    Wan, Minggang; Zhuang, Jihui

    2018-04-01

    For flame chemiluminescence tomography (FCT) based on lens imaging, the projection model is essential because it formulates the mathematical relation between the flame projections captured by cameras and the chemiluminescence field, and, through this relation, the field is reconstructed. This work proposed the blurry-spot (BS) model, which takes more universal assumptions and has higher accuracy than the widely applied line-of-sight model. By combining the geometrical camera model and the thin-lens equation, the BS model takes into account perspective effect of the camera lens; by combining ray-tracing technique and Monte Carlo simulation, it also considers inhomogeneous distribution of captured radiance on the image plane. Performance of these two models in FCT was numerically compared, and results showed that using the BS model could lead to better reconstruction quality in wider application ranges.

  12. Image reconstruction from projections and its application in emission computer tomography

    International Nuclear Information System (INIS)

    Kuba, Attila; Csernay, Laszlo

    1989-01-01

    Computer tomography is an imaging technique for producing cross sectional images by reconstruction from projections. Its two main branches are called transmission and emission computer tomography, TCT and ECT, resp. After an overview of the theory and practice of TCT and ECT, the first Hungarian ECT type MB 9300 SPECT consisting of a gamma camera and Ketronic Medax N computer is described, and its applications to radiological patient observations are discussed briefly. (R.P.) 28 refs.; 4 figs

  13. Computed tomography of a medium size Roman bronze statue of Cupid

    Science.gov (United States)

    Bettuzzi, M.; Casali, F.; Morigi, M. P.; Brancaccio, R.; Carson, D.; Chiari, G.; Maish, J.

    2015-03-01

    Diagnostics based on X-ray computed tomography (CT) are becoming increasingly important, not only in the medical field but in industry and cultural heritage. CT devices typical for medical applications, however, can seldom be used on art objects because both they are not easily transportable and they often present high X-ray absorption. It is therefore necessary to make use of portable instrumentation and/or to develop tomographic systems optimized to the characteristics of the objects under examination. This work describes the computed tomography of a first century A.D. Roman bronze statue of Cupid (96.AB.53) in the collection of the J. Paul Getty Museum, within the collaborative framework between the Getty Conservation Institute and the Department of Physics and Astronomy (DIFA) of the University of Bologna (Italy). The tomography performed at the Getty facilities employed a 450 kV X-ray tube and a detection system developed at DIFA. The study highlighted the casting and construction techniques used by Roman foundry workers and provided information on the status of conservation of the statue. A 3D virtual reconstruction allowed the user to define different cross-sections enabling the study of the internal features.

  14. Metaanalysis of Diagnostic Performance of Computed Coronary Tomography Angiography, Computed Tomography Perfusion and Computed Tomography-Fractional Flow Reserve in Functional Myocardial Ischemia Assessment versus Invasive Fractional Flow Reserve

    Science.gov (United States)

    Gonzalez, Jorge A.; Lipinski, Michael J.; Flors, Lucia F.; Shaw, Peter; Kramer, Christopher M.; Salerno, Michael

    2015-01-01

    We sought to compare the diagnostic performance of computed coronary tomography angiography (CCTA), computed tomography perfusion (CTP) and computed tomography fractional flow reserve (CT-FFR) for assessing the functional significance of coronary stenosis as defined by invasive fractional flow reserve (FFR), in patients with known or suspected coronary artery disease. CCTA has proven clinically useful for excluding obstructive CAD due to its high sensitivity and negative predictive value (NPV), however the ability of CTA to identify functionally significant CAD has remained challenging. We searched PubMed/Medline for studies evaluating CCTA, CTP or CT-FFR for the non-invasive detection of obstructive CAD as compared to catheter-derived FFR as the reference standard. Pooled sensitivity, specificity, PPV, NPV, likelihood ratios (LR), odds ratio (OR) of all diagnostic tests were assessed. Eighteen studies involving a total of 1535 patients were included. CTA demonstrated a pooled sensitivity of 0.92, specificity 0.43, PPV of 0.56 and NPV of 0.87 on a per-patient level. CT-FFR and CTP increased the specificity to 0.72 and 0.77 respectively (P=0.004 and P=0.0009)) resulting in higher point estimates for PPV 0.70 and 0.83 respectively. There was no improvement in the sensitivity. The CTP protocol involved more radiation (3.5 mSv CCTA VS 9.6 mSv CTP) and a higher volume of iodinated contrast (145 mL). In conclusion, CTP and CT-FFR improve the specificity of CCTA for detecting functionally significant stenosis as defined by invasive FFR on a per-patient level; both techniques could advance the ability to non-invasively detect the functional significance of coronary lesions. PMID:26347004

  15. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  16. Construction of three-dimensional tooth model by micro-computed tomography and application for data sharing.

    Science.gov (United States)

    Kato, A; Ohno, N

    2009-03-01

    The study of dental morphology is essential in terms of phylogeny. Advances in three-dimensional (3D) measurement devices have enabled us to make 3D images of teeth without destruction of samples. However, raw fundamental data on tooth shape requires complex equipment and techniques. An online database of 3D teeth models is therefore indispensable. We aimed to explore the basic methodology for constructing 3D teeth models, with application for data sharing. Geometric information on the human permanent upper left incisor was obtained using micro-computed tomography (micro-CT). Enamel, dentine, and pulp were segmented by thresholding of different gray-scale intensities. Segmented data were separately exported in STereo-Lithography Interface Format (STL). STL data were converted to Wavefront OBJ (OBJect), as many 3D computer graphics programs support the Wavefront OBJ format. Data were also applied to Quick Time Virtual Reality (QTVR) format, which allows the image to be viewed from any direction. In addition to Wavefront OBJ and QTVR data, the original CT series were provided as 16-bit Tag Image File Format (TIFF) images on the website. In conclusion, 3D teeth models were constructed in general-purpose data formats, using micro-CT and commercially available programs. Teeth models that can be used widely would benefit all those who study dental morphology.

  17. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tokihiro, E-mail: toyamamoto@ucdavis.edu [Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California 95817 (United States); Kent, Michael S.; Wisner, Erik R. [Department of Surgical and Radiological Sciences, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Johnson, Lynelle R.; Stern, Joshua A. [Department of Medicine and Epidemiology, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Qi, Lihong [Department of Public Health Sciences, University of California Davis, Davis, California 95616 (United States); Fujita, Yukio [Department of Radiation Oncology, Tokai University, Isehara, Kanagawa 259-1193 (Japan); Boone, John M. [Department of Radiology, University of California Davis School of Medicine, Sacramento, California 95817 (United States)

    2016-07-15

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  18. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model.

    Science.gov (United States)

    Yamamoto, Tokihiro; Kent, Michael S; Wisner, Erik R; Johnson, Lynelle R; Stern, Joshua A; Qi, Lihong; Fujita, Yukio; Boone, John M

    2016-07-01

    Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. The mean TRE

  19. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    International Nuclear Information System (INIS)

    Yamamoto, Tokihiro; Kent, Michael S.; Wisner, Erik R.; Johnson, Lynelle R.; Stern, Joshua A.; Qi, Lihong; Fujita, Yukio; Boone, John M.

    2016-01-01

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  20. A computer-aided system for automatic extraction of femur neck trabecular bone architecture using isotropic volume construction from clinical hip computed tomography images.

    Science.gov (United States)

    Vivekanandhan, Sapthagirivasan; Subramaniam, Janarthanam; Mariamichael, Anburajan

    2016-10-01

    Hip fractures due to osteoporosis are increasing progressively across the globe. It is also difficult for those fractured patients to undergo dual-energy X-ray absorptiometry scans due to its complicated protocol and its associated cost. The utilisation of computed tomography for the fracture treatment has become common in the clinical practice. It would be helpful for orthopaedic clinicians, if they could get some additional information related to bone strength for better treatment planning. The aim of our study was to develop an automated system to segment the femoral neck region, extract the cortical and trabecular bone parameters, and assess the bone strength using an isotropic volume construction from clinical computed tomography images. The right hip computed tomography and right femur dual-energy X-ray absorptiometry measurements were taken from 50 south-Indian females aged 30-80 years. Each computed tomography image volume was re-constructed to form isotropic volumes. An automated system by incorporating active contour models was used to segment the neck region. A minimum distance boundary method was applied to isolate the cortical and trabecular bone components. The trabecular bone was enhanced and segmented using trabecular enrichment approach. The cortical and trabecular bone features were extracted and statistically compared with dual-energy X-ray absorptiometry measured femur neck bone mineral density. The extracted bone measures demonstrated a significant correlation with neck bone mineral density (r > 0.7, p computed tomography images scanned with low dose could eventually be helpful in osteoporosis diagnosis and its treatment planning. © IMechE 2016.

  1. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)

  2. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    International Nuclear Information System (INIS)

    Yeung, Timothy P C; Yartsev, Slav; Lee, Ting-Yim; Wong, Eugene; He, Wenqing; Fisher, Barbara; VanderSpek, Lauren L; Macdonald, David; Bauman, Glenn

    2014-01-01

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity

  3. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, Timothy P C [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Lee, Ting-Yim [Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Imaging, The University of Western Ontario, London Health Sciences Centre, Victoria Hospital, Ontario, Canada, N6A 5W9 (Australia); Lawson Health Research Institute, St. Joseph' s Health Care London, Ontario, Canada, N6A 4V2 (Canada); Wong, Eugene [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Physics and Astronomy, The University of Western Ontario, Ontario, Canada, N6A 3K7 (Canada); He, Wenqing [Department of Statistical and Actuarial Sciences, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Fisher, Barbara; VanderSpek, Lauren L [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Macdonald, David [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Clinical Neurological Sciences, The University of Western Ontario, London Health Sciences Centre, University Hospital, Ontario, Canada, N6A 5A5 (Canada); Bauman, Glenn, E-mail: glenn.bauman@lhsc.on.ca [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada)

    2014-02-15

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity.

  4. A novel dual energy method for enhanced quantitative computed tomography

    Science.gov (United States)

    Emami, A.; Ghadiri, H.; Rahmim, A.; Ay, M. R.

    2018-01-01

    Accurate assessment of bone mineral density (BMD) is critically important in clinical practice, and conveniently enabled via quantitative computed tomography (QCT). Meanwhile, dual-energy QCT (DEQCT) enables enhanced detection of small changes in BMD relative to single-energy QCT (SEQCT). In the present study, we aimed to investigate the accuracy of QCT methods, with particular emphasis on a new dual-energy approach, in comparison to single-energy and conventional dual-energy techniques. We used a sinogram-based analytical CT simulator to model the complete chain of CT data acquisitions, and assessed performance of SEQCT and different DEQCT techniques in quantification of BMD. We demonstrate a 120% reduction in error when using a proposed dual-energy Simultaneous Equation by Constrained Least-squares method, enabling more accurate bone mineral measurements.

  5. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... applications. This thesis takes a systematic approach toward establishing quantitative understanding of conditions for sparse reconstruction to work well in CT. A general framework for analyzing sparse reconstruction methods in CT is introduced and two sets of computational tools are proposed: 1...... contributions to a general set of computational characterization tools. Thus, the thesis contributions help advance sparse reconstruction methods toward routine use in...

  6. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  7. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  8. Accuracy of volumetric measurement of simulated root resorption lacunas based on cone beam computed tomography.

    Science.gov (United States)

    Wang, Y; He, S; Guo, Y; Wang, S; Chen, S

    2013-08-01

    To evaluate the accuracy of volumetric measurement of simulated root resorption cavities based on cone beam computed tomography (CBCT), in comparison with that of Micro-computed tomography (Micro-CT) which served as the reference. The State Key Laboratory of Oral Diseases at Sichuan University. Thirty-two bovine teeth were included for standardized CBCT scanning and Micro-CT scanning before and after the simulation of different degrees of root resorption. The teeth were divided into three groups according to the depths of the root resorption cavity (group 1: 0.15, 0.2, 0.3 mm; group 2: 0.6, 1.0 mm; group 3: 1.5, 2.0, 3.0 mm). Each depth included four specimens. Differences in tooth volume before and after simulated root resorption were then calculated from CBCT and Micro-CT scans, respectively. The overall between-method agreement of the measurements was evaluated using the concordance correlation coefficient (CCC). For the first group, the average volume of resorption cavity was 1.07 mm(3) , and the between-method agreement of measurement for the volume changes was low (CCC = 0.098). For the second and third groups, the average volumes of resorption cavities were 3.47 and 6.73 mm(3) respectively, and the between-method agreements were good (CCC = 0.828 and 0.895, respectively). The accuracy of 3-D quantitative volumetric measurement of simulated root resorption based on CBCT was fairly good in detecting simulated resorption cavities larger than 3.47 mm(3), while it was not sufficient for measuring resorption cavities smaller than 1.07 mm(3) . This method could be applied in future studies of root resorption although further studies are required to improve its accuracy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Impact of knowledge-based iterative model reconstruction on myocardial late iodine enhancement in computed tomography and comparison with cardiac magnetic resonance.

    Science.gov (United States)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Fukuyama, Naoki; Yokoi, Takahiro; Kido, Tomoyuki; Uetani, Teruyoshi; Vembar, Mani; Dhanantwari, Amar; Tokuyasu, Shinichi; Yamashita, Natsumi; Mochizuki, Teruhito

    2017-10-01

    We evaluated the image quality and diagnostic performance of late iodine enhancement computed tomography (LIE-CT) with knowledge-based iterative model reconstruction (IMR) for the detection of myocardial infarction (MI) in comparison with late gadolinium enhancement magnetic resonance imaging (LGE-MRI). The study investigated 35 patients who underwent a comprehensive cardiac CT protocol and LGE-MRI for the assessment of coronary artery disease. The CT protocol consisted of stress dynamic myocardial CT perfusion, coronary CT angiography (CTA) and LIE-CT using 256-slice CT. LIE-CT scans were acquired 5 min after CTA without additional contrast medium and reconstructed with filtered back projection (FBP), a hybrid iterative reconstruction (HIR), and IMR. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed. Sensitivity and specificity of LIE-CT for detecting MI were assessed according to the 16-segment model. Image quality scores, and diagnostic performance were compared among LIE-CT with FBP, HIR and IMR. Among the 35 patients, 139 of 560 segments showed MI in LGE-MRI. On LIE-CT with FBP, HIR, and IMR, the median SNRs were 2.1, 2.9, and 6.1; and the median CNRs were 1.7, 2.2, and 4.7, respectively. Sensitivity and specificity were 56 and 93% for FBP, 62 and 91% for HIR, and 80 and 91% for IMR. LIE-CT with IMR showed the highest image quality and sensitivity (p quality and diagnostic performance of LIE-CT for detecting MI in comparison with FBP and HIR.

  10. Differences between postmortem computed tomography and conventional autopsy in a stabbing murder case

    Directory of Open Access Journals (Sweden)

    Talita Zerbini

    2014-12-01

    Full Text Available Objective: The aim of the present work is to analyze the differences and similarities between the elements of a conventional autopsy and images obtained from postmortem computed tomography in a case of a homicide stab wound. Method: Comparison between the findings of different methods: autopsy and postmortem computed tomography. Results: In some aspects, autopsy is still superior to imaging, especially in relation to external examination and the description of lesion vitality. However, the findings of gas embolism, pneumothorax and pulmonary emphysema and the relationship between the internal path of the instrument of aggression and the entry wound are better demonstrated by postmortem computed tomography. Conclusions: Although multislice computed tomography has greater accuracy than autopsy, we believe that the conventional autopsy method is fundamental for providing evidence in criminal investigations.

  11. Epicardial adipose tissue volume estimation by postmortem computed tomography of eviscerated hearts

    DEFF Research Database (Denmark)

    Hindsø, Louise; Jakobsen, Lykke S; Jacobsen, Christina

    2017-01-01

    Epicardial adipose tissue (EAT) may play a role in the development of coronary artery disease. The purpose of this study was to evaluate a method based on postmortem computed tomography (PMCT) for the estimation of EAT volume. We PMCT-scanned the eviscerated hearts of 144 deceased individuals, wh...

  12. Image quality in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Gerke, Oke; Thygesen, Jesper

    2018-01-01

    Background Computed tomography (CT) technology is rapidly evolving and software solution developed to optimize image quality and/or lower radiation dose. Purpose To investigate the influence of adaptive statistical iterative reconstruction (ASIR) at different radiation doses in coronary CT...

  13. Quantitative analysis and prediction of regional lymph node status in rectal cancer based on computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Chunyan; Liu, Lizhi; Li, Li [Sun Yat-sen University, State Key Laboratory of Oncology in Southern China, Imaging Diagnosis and Interventional Center, Cancer Center, Guangzhou, Guangdong (China); Cai, Hongmin; Tian, Haiying [Sun Yat-Sen University, Department of Automation, School of Science Information and Technology, Guangzhou (China); Li, Liren [Sun Yat-sen University, State Key Laboratory of Oncology in Southern China, Department of Abdominal (colon and rectal) Surgery, Cancer Center, Guangzhou (China)

    2011-11-15

    To quantitatively evaluate regional lymph nodes in rectal cancer patients by using an automated, computer-aided approach, and to assess the accuracy of this approach in differentiating benign and malignant lymph nodes. Patients (228) with newly diagnosed rectal cancer, confirmed by biopsy, underwent enhanced computed tomography (CT). Patients were assigned to the benign node or malignant node group according to histopathological analysis of node samples. All CT-detected lymph nodes were segmented using the edge detection method, and seven quantitative parameters of each node were measured. To increase the prediction accuracy, a hierarchical model combining the merits of the support and relevance vector machines was proposed to achieve higher performance. Of the 220 lymph nodes evaluated, 125 were positive and 95 were negative for metastases. Fractal dimension obtained by the Minkowski box-counting approach was higher in malignant nodes than in benign nodes, and there was a significant difference in heterogeneity between metastatic and non-metastatic lymph nodes. The overall performance of the proposed model is shown to have accuracy as high as 88% using morphological characterisation of lymph nodes. Computer-aided quantitative analysis can improve the prediction of node status in rectal cancer. (orig.)

  14. Computed tomography contribution to the staging of supraglottic squamous cell carcinoma

    International Nuclear Information System (INIS)

    Monte Aragao Junior, Antonio Gilson; Rapoport, Abrao; Souza, Ricardo Pires de

    2007-01-01

    Objective: The present study was aimed at evaluating the role of computed tomography in the local clinical staging of supraglottic tumors according to the TNM classification, as well as the interobserver agreement on the detection of the tumor extent. Materials and methods: Thirty-nine dossiers of inpatients of Hospital Heliopolis with supraglottic squamous cell carcinoma in the period between 1988 and 1998 were retrospectively evaluated. CT studies were individually analyzed by two radiologists. The kappa test was utilized for evaluating the interobserver agreement. Results: Computed tomography has played a decisive role in the upstaging of 38.5% of cases, as a result of a deep tumor extent undetected at clinical examination. Conclusion: Interobserver agreement was considered as excellent for vocal folds and subglottis; good for supraglottic, paraglottic and preepiglottic spaces, thyroid and cricoid cartilages and for extralaryngeal tumor extension; and regular for the base of the tongue. (author)

  15. Computed tomography of the abnormal thymus

    International Nuclear Information System (INIS)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion

  16. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  17. Reconstructed frontal and coronal cuts in computed tomography of the trunk

    International Nuclear Information System (INIS)

    Fochem, K.; Klumair, J.

    1982-01-01

    A comparison between the original coronally cuts and the reconstructed coronal cuts yielded basic information on the loss of quality by computed reconstruction of images. As for the trunk, only comparisons between the conventional linear tomography and computed frontal of trunk cuts are possible. A few examples will demonstrate that despite a considerable loss of quality, computed frontal cuts will supply additional information in certain cases. It is also shown that the reconstructed frontal cuts cannot replace conventional tomography. (orig.) [de

  18. The Dimensions of the Orbital Cavity Based on High-Resolution Computed Tomography of Human Cadavers

    DEFF Research Database (Denmark)

    Felding, Ulrik Ascanius; Bloch, Sune Land; Buchwald, Christian von

    2016-01-01

    for surface area. To authors' knowledge, this study is the first to have measured the entire surface area of the orbital cavity.The volume and surface area of the orbital cavity were estimated in computed tomography scans of 11 human cadavers using unbiased stereological sampling techniques. The mean (± SD......) total volume and total surface area of the orbital cavities was 24.27 ± 3.88 cm and 32.47 ± 2.96 cm, respectively. There was no significant difference in volume (P = 0.315) or surface area (P = 0.566) between the 2 orbital cavities.The stereological technique proved to be a robust and unbiased method...... that may be used as a gold standard for comparison with automated computer software. Future imaging studies in blow-out fracture patients may be based on individual and relative calculation involving both herniated volume and fractured surface area in relation to the total volume and surface area...

  19. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research.

    Science.gov (United States)

    Bornstein, Michael M; Horner, Keith; Jacobs, Reinhilde

    2017-02-01

    Diagnostic radiology is an essential component of treatment planning in the field of implant dentistry. This narrative review will present current concepts for the use of cone beam computed tomography imaging, before and after implant placement, in daily clinical practice and research. Guidelines for the selection of three-dimensional imaging will be discussed, and limitations will be highlighted. Current concepts of radiation dose optimization, including novel imaging modalities using low-dose protocols, will be presented. For preoperative cross-sectional imaging, data are still not available which demonstrate that cone beam computed tomography results in fewer intraoperative complications such as nerve damage or bleeding incidents, or that implants inserted using preoperative cone beam computed tomography data sets for planning purposes will exhibit higher survival or success rates. The use of cone beam computed tomography following the insertion of dental implants should be restricted to specific postoperative complications, such as damage of neurovascular structures or postoperative infections in relation to the maxillary sinus. Regarding peri-implantitis, the diagnosis and severity of the disease should be evaluated primarily based on clinical parameters and on radiological findings based on periapical radiographs (two dimensional). The use of cone beam computed tomography scans in clinical research might not yield any evident beneficial effect for the patient included. As many of the cone beam computed tomography scans performed for research have no direct therapeutic consequence, dose optimization measures should be implemented by using appropriate exposure parameters and by reducing the field of view to the actual region of interest. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  1. Positron Emission Tomography/Computed Tomography Imaging of Residual Skull Base Chordoma Before Radiotherapy Using Fluoromisonidazole and Fluorodeoxyglucose: Potential Consequences for Dose Painting

    Energy Technology Data Exchange (ETDEWEB)

    Mammar, Hamid, E-mail: hamid.mammar@unice.fr [Radiation Oncology Department, Antoine Lacassagne Center, Nice (France); CNRS-UMR 6543, Institute of Developmental Biology and Cancer, University of Nice Sophia Antipolis, Nice (France); Kerrou, Khaldoun; Nataf, Valerie [Department of Nuclear Medicine and Radiopharmacy, Tenon Hospital, and University Pierre et Marie Curie, Paris (France); Pontvert, Dominique [Proton Therapy Center of Orsay, Curie Institute, Paris (France); Clemenceau, Stephane [Department of Neurosurgery, Pitie-Salpetriere Hospital, Paris (France); Lot, Guillaume [Department of Neurosurgery, Adolph De Rothschild Foundation, Paris (France); George, Bernard [Department of Neurosurgery, Lariboisiere Hospital, Paris (France); Polivka, Marc [Department of Pathology, Lariboisiere Hospital, Paris (France); Mokhtari, Karima [Department of Pathology, Pitie-Salpetriere Hospital, Paris (France); Ferrand, Regis; Feuvret, Loiec; Habrand, Jean-louis [Proton Therapy Center of Orsay, Curie Institute, Paris (France); Pouyssegur, Jacques; Mazure, Nathalie [CNRS-UMR 6543, Institute of Developmental Biology and Cancer, University of Nice Sophia Antipolis, Nice (France); Talbot, Jean-Noeel [Department of Nuclear Medicine and Radiopharmacy, Tenon Hospital, and University Pierre et Marie Curie, Paris (France)

    2012-11-01

    Purpose: To detect the presence of hypoxic tissue, which is known to increase the radioresistant phenotype, by its uptake of fluoromisonidazole (18F) (FMISO) using hybrid positron emission tomography/computed tomography (PET/CT) imaging, and to compare it with the glucose-avid tumor tissue imaged with fluorodeoxyglucose (18F) (FDG), in residual postsurgical skull base chordoma scheduled for radiotherapy. Patients and Methods: Seven patients with incompletely resected skull base chordomas were planned for high-dose radiotherapy (dose {>=}70 Gy). All 7 patients underwent FDG and FMISO PET/CT. Images were analyzed qualitatively by visual examination and semiquantitatively by computing the ratio of the maximal standardized uptake value (SUVmax) of the tumor and cerebellum (T/C R), with delineation of lesions on conventional imaging. Results: Of the eight lesion sites imaged with FDG PET/CT, only one was visible, whereas seven of nine lesions were visible on FMISO PET/CT. The median SUVmax in the tumor area was 2.8 g/mL (minimum 2.1; maximum 3.5) for FDG and 0.83 g/mL (minimum 0.3; maximum 1.2) for FMISO. The T/C R values ranged between 0.30 and 0.63 for FDG (median, 0.41) and between 0.75 and 2.20 for FMISO (median,1.59). FMISO T/C R >1 in six lesions suggested the presence of hypoxic tissue. There was no correlation between FMISO and FDG uptake in individual chordomas (r = 0.18, p = 0.7). Conclusion: FMISO PET/CT enables imaging of the hypoxic component in residual chordomas. In the future, it could help to better define boosted volumes for irradiation and to overcome the radioresistance of these lesions. No relationship was founded between hypoxia and glucose metabolism in these tumors after initial surgery.

  2. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Isherwood, I.; Antoun, N.M.

    1984-01-01

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  3. Influence of 18F-fluorodeoxyglucose-positron emission tomography on computed tomography-based radiation treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Everitt, C.; Leong, T.

    2006-01-01

    The addition of positron emission tomography (PET) information to CT-based radiotherapy treatment planning has the potential to improve target volume definition through more accurate localization of the primary tumour and involved regional lymph nodes. This case report describes the first patient enrolled to a prospective study evaluating the effects of coregistered positron emission tomography/CT images on radiotherapy treatment planning for oesophageal cancer. The results show that if combined positron emission tomography/CT is used for radiotherapy treatment planning, there may be alterations to the delineation of tumour volumes when compared to CT alone. For this patient, a geographic miss of tumour would have occurred if CT data alone were used for radiotherapy planning Copyright (2006) Blackwell Publishing Asia Pty Ltd

  4. Novel prediction model of renal function after nephrectomy from automated renal volumetry with preoperative multidetector computed tomography (MDCT).

    Science.gov (United States)

    Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; Noma, Yasuhiro; Kitamura, Kousuke; China, Toshiyuki; Saito, Keisuke; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Gill, Inderbir S; Horie, Shigeo

    2015-10-01

    The predictive model of postoperative renal function may impact on planning nephrectomy. To develop the novel predictive model using combination of clinical indices with computer volumetry to measure the preserved renal cortex volume (RCV) using multidetector computed tomography (MDCT), and to prospectively validate performance of the model. Total 60 patients undergoing radical nephrectomy from 2011 to 2013 participated, including a development cohort of 39 patients and an external validation cohort of 21 patients. RCV was calculated by voxel count using software (Vincent, FUJIFILM). Renal function before and after radical nephrectomy was assessed via the estimated glomerular filtration rate (eGFR). Factors affecting postoperative eGFR were examined by regression analysis to develop the novel model for predicting postoperative eGFR with a backward elimination method. The predictive model was externally validated and the performance of the model was compared with that of the previously reported models. The postoperative eGFR value was associated with age, preoperative eGFR, preserved renal parenchymal volume (RPV), preserved RCV, % of RPV alteration, and % of RCV alteration (p volumetry and clinical indices might yield an important tool for predicting postoperative renal function.

  5. Three dimensional computed tomography lung modeling is useful in simulation and navigation of lung cancer surgery.

    Science.gov (United States)

    Ikeda, Norihiko; Yoshimura, Akinobu; Hagiwara, Masaru; Akata, Soichi; Saji, Hisashi

    2013-01-01

    The number of minimally invasive operations, such as video-assisted thoracoscopic surgery (VATS) lobectomy or segmentectomy, has enormously increased in recent years. These operations require extreme knowledge of the anatomy of pulmonary vessels and bronchi in each patient, and surgeons must carefully dissect the branches of pulmonary vessels during operation. Thus, foreknowledge of the anatomy of each patient would greatly contribute to the safety and accuracy of the operation. The development of multi-detector computed tomography (MDCT) has promoted three dimensional (3D) images of lung structures. It is possible to see the vascular and bronchial structures from the view of the operator; therefore, it is employed for preoperative simulation as well as navigation during operation. Due to advances in software, even small vessels can be accurately imaged, which is useful in performing segmentectomy. Surgical simulation and navigation systems based on high quality 3D lung modeling, including vascular and bronchial structures, can be used routinely to enhance the safety operation, education of junior staff, as well as providing a greater sense of security to the operators.

  6. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Rodrigo da Fonseca Monjardim

    2013-06-01

    Full Text Available Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

  7. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    International Nuclear Information System (INIS)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D'Ippolito, Giuseppe

    2013-01-01

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  8. Lung Hot Spot Without Corresponding Computed Tomography Abnormality on Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Artifactual or Real, Iatrogenic or Pathologic?

    Science.gov (United States)

    Liu, Yiyan

    Focal lung uptake without corresponding lesions or abnormalities on computed tomography (CT) scan poses a dilemma in the interpretation of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). A limited number of case reports have previously suggested an artifactual or iatrogenic nature of the uptake. In the present study, 8 relevant cases were included within a retrospective search of the database. Medical records were reviewed for follow-up radiological and pathologic information. In 7 of 8 cases with focal increased FDG uptake but no corresponding lesions or abnormalities on CT scan, the lung hot spots were artifactual or iatrogenic upon follow-up diagnostic chest CT or repeated PET/CT or both the scans. Microemboli were most likely a potential cause of the pulmonary uptake, with or without partial paravenous injection. One case in the series had a real pulmonary lesion demonstrated on follow-up PET/CT scans and on surgical pathology, although the initial integrated CT and follow-up diagnostic chest CT scans revealed negative findings to demonstrate pulmonary abnormalities corresponding to the hot spot on the PET scan. In conclusion, the finding of a lung hot spot in the absence of anatomical abnormality on FDG PET/CT was most likely artifactual or iatrogenic, but it might also represent a real pulmonary lesion. Nonvisualization of anatomical abnormality could be because of its small size and position directly overlying a segmental vessel. Further image follow-up is necessary and important to clarify the nature of the uptake. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Applicability of a geometrical model coupled to computed tomography to characterize the transport properties of porous materials: comparison with through diffusion experiments

    International Nuclear Information System (INIS)

    Chagneau, Aurelie; Claret, Francis; Made, Benoit; Tuckermann, Juergen; Enzmann, Frieder; Schaefer, Thorsten

    2012-01-01

    they contain a heavy element (Sr) that can easily be differentiated from the lighter matrix elements (Si, Al) by tomography. The diffusion columns used consist of two reservoirs, one containing the strontium and radiotracer and the other the sulfate or carbonate stock solutions, one at each end of a 5 cm long column. Before any precipitation experiments, the De and porosity of the materials are characterized by realizing diffusion profiles of tritiated water (HTO), and the results are compared to a geometrical model of the material based on computed tomography observations. For this purpose, the images obtained by CT are reconstructed in three dimensions and then processed by separating the porous material and the pore network. The 3D reconstruction of the pore network is directly implemented into a geometrical model, GeoDict, to calculate the different properties of the material (e.g. porosity, tortuosity, diffusivity). The results obtained by the two different experimental approaches compare fairly well. For example, the connected porosity of a column filled with silica beads of 40 to 70 μm particle size was estimated at 0.39 by HTO diffusion and at 0.40 to 0.45 by computed tomography coupled to GeoDict. Computed tomography is a simple yet efficient method, when coupled to a geometrical model, to record the evolution of porosity with time, and to accurately estimate the impact of clogging on the diffusion properties of porous materials, without disturbing the system. To this characterization method will be added in further steps post mortem analyses by microscopic methods, microprobe and synchrotron μ-tomography. In parallel, experiments in the presence of trivalent actinides are planned to compare the chemical speciation during secondary phase formation in compacted systems with data already available obtained in batch-type and mixed flow reactor (MFR) experiments. (authors)

  10. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  11. Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans

    NARCIS (Netherlands)

    Al-Rawi, B.; Hassan, B.; Vandenberge, B.; Jacobs, R.

    2010-01-01

    The use of three-dimensional (3D) models of the dentition obtained from cone beam computed tomography (CBCT) is becoming increasingly more popular in dentistry. A recent trend is to replace the traditional dental casts with digital CBCT models for diagnosis, treatment planning and simulation. The

  12. Our experience in the diagnosis of aortic dissection by multislice computed tomography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis R; Mendoza Rodriguez, Vladimir; Olivares Aquiles, Eddy

    2011-01-01

    Aortic dissection (AD) is the most frequent and life-threatening acute aortic syndrome. Currently the more used method for the aortic study is the multislice computed tomography. The purpose of this paper is to expose the more relevant features in 22 patients with AD consecutively studied by multislice computed tomography

  13. Italian Chapter of the International Society of Cardiovascular Ultrasound expert consensus document on coronary computed tomography angiography: overview and new insights.

    Science.gov (United States)

    Sozzi, Fabiola B; Maiello, Maria; Pelliccia, Francesco; Parato, Vito Maurizio; Canetta, Ciro; Savino, Ketty; Lombardi, Federico; Palmiero, Pasquale

    2016-09-01

    Coronary computed tomography angiography is a noninvasive heart imaging test currently undergoing rapid development and advancement. The high resolution of the three-dimensional pictures of the moving heart and great vessels is performed during a coronary computed tomography to identify coronary artery disease and classify patient risk for atherosclerotic cardiovascular disease. The technique provides useful information about the coronary tree and atherosclerotic plaques beyond simple luminal narrowing and plaque type defined by calcium content. This application will improve image-guided prevention, medical therapy, and coronary interventions. The ability to interpret coronary computed tomography images is of utmost importance as we develop personalized medical care to enable therapeutic interventions stratified on the bases of plaque characteristics. This overview provides available data and expert's recommendations in the utilization of coronary computed tomography findings. We focus on the use of coronary computed tomography to detect coronary artery disease and stratify patients at risk, illustrating the implications of this test on patient management. We describe its diagnostic power in identifying patients at higher risk to develop acute coronary syndrome and its prognostic significance. Finally, we highlight the features of the vulnerable plaques imaged by coronary computed tomography angiography. © 2016, Wiley Periodicals, Inc.

  14. High-resolution computed tomography and histopathological findings in hypersensitivity pneumonitis: a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Pedro Paulo Teixeira e Silva; Moreira, Marise Amaral Reboucas; Silva, Daniela Graner Schuwartz Tannus; Moreira, Maria Auxiliadora do Carmo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil); Gama, Roberta Rodrigues Monteiro da [Hospital do Cancer de Barretos, Barretos, SP (Brazil); Sugita, Denis Masashi, E-mail: pedroptstorres@yahoo.com.br [Anapolis Unievangelica, Anapolis, GO (Brazil)

    2016-03-15

    Hypersensitivity pneumonitis is a diffuse interstitial and granulomatous lung disease caused by the inhalation of any one of a number of antigens. The objective of this study was to illustrate the spectrum of abnormalities in high-resolution computed tomography and histopathological findings related to hypersensitivity pneumonitis. We retrospectively evaluated patients who had been diagnosed with hypersensitivity pneumonitis (on the basis of clinical-radiological or clinical-radiological-pathological correlations) and had undergone lung biopsy. Hypersensitivity pneumonitis is clinically divided into acute, subacute, and chronic forms; high-resolution computed tomography findings correlate with the time of exposure; and the two occasionally overlap. In the subacute form, centrilobular micronodules, ground glass opacities, and air trapping are characteristic high-resolution computed tomography findings, whereas histopathology shows lymphocytic inflammatory infiltrates, bronchiolitis, variable degrees of organizing pneumonia, and giant cells. In the chronic form, high-resolution computed tomography shows traction bronchiectasis, honeycombing, and lung fibrosis, the last also being seen in the biopsy sample. A definitive diagnosis of hypersensitivity pneumonitis can be made only through a multidisciplinary approach, by correlating clinical findings, exposure history, high-resolution computed tomography findings, and lung biopsy findings. (author)

  15. Regorafenib effects on human colon carcinoma xenografts monitored by dynamic contrast-enhanced computed tomography with immunohistochemical validation.

    Directory of Open Access Journals (Sweden)

    Clemens C Cyran

    Full Text Available To investigate dynamic contrast-enhanced computed tomography for monitoring the effects of regorafenib on experimental colon carcinomas in rats by quantitative assessments of tumor microcirculation parameters with immunohistochemical validation.Colon carcinoma xenografts (HT-29 implanted subcutaneously in female athymic rats (n = 15 were imaged at baseline and after a one-week treatment with regorafenib by dynamic contrast-enhanced computed tomography (128-slice dual-source computed tomography. The therapy group (n = 7 received regorafenib daily (10 mg/kg bodyweight. Quantitative parameters of tumor microcirculation (plasma flow, mL/100 mL/min, endothelial permeability (PS, mL/100 mL/min, and tumor vascularity (plasma volume, % were calculated using a 2-compartment uptake model. Dynamic contrast-enhanced computed tomography parameters were validated with immunohistochemical assessments of tumor microvascular density (CD-31, tumor cell apoptosis (TUNEL, and proliferation (Ki-67.Regorafenib suppressed tumor vascularity (15.7±5.3 to 5.5±3.5%; p<0.05 and tumor perfusion (12.8±2.3 to 8.8±2.9 mL/100 mL/min; p = 0.063. Significantly lower microvascular density was observed in the therapy group (CD-31; 48±10 vs. 113±25, p<0.05. In regorafenib-treated tumors, significantly more apoptotic cells (TUNEL; 11844±2927 vs. 5097±3463, p<0.05 were observed. Dynamic contrast-enhanced computed tomography tumor perfusion and tumor vascularity correlated significantly (p<0.05 with microvascular density (CD-31; r = 0.84 and 0.66 and inversely with apoptosis (TUNEL; r = -0.66 and -0.71.Regorafenib significantly suppressed tumor vascularity (plasma volume quantified by dynamic contrast-enhanced computed tomography in experimental colon carcinomas in rats with good-to-moderate correlations to an immunohistochemical gold standard. Tumor response biomarkers assessed by dynamic contrast-enhanced computed tomography may be a promising future

  16. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  17. Investigation of measuring strategies in computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2011-01-01

    Computed tomography has entered the industrial world in 1980’s as a technique for non-destructive testing and has nowadays become a revolutionary tool for dimensional metrology, suitable for actual/nominal comparison and verification of geometrical and dimensional tolerances. This paper evaluates...

  18. Studying fatigue damage evolution in uni-directional composites using x-ray computed tomography

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard

    , it will be possible to lower the costs of energy for wind energy based electricity. In the present work, a lab-source x-ray computed tomography equipment (Zeiss Xradia 520 Versa) has been used in connection with ex-situ fatigue testing of uni-directional composites in order to identify fibre failure during...... comparable x-ray studies) have been used in order to ensure a representative test volume during the ex-situ fatigue testing. Using the ability of the x-ray computed tomography to zoom into regions of interest, non-destructive, the fatigue damage evolution in a repeating ex-situ fatigue loaded test sample has...... improving the fatigue resistance of non-crimp fabric used in the wind turbine industry can be made....

  19. Comparative study of mesothelioma and asbestosis using computed tomography and conventional chest radiography

    International Nuclear Information System (INIS)

    Rabinowitz, T.G.; Efremidis, S.C.; Cohen, B.; Dan, S.; Efremidis, A.; Chahinian, A.P.; Teirstein, A.S.

    1982-01-01

    A comparative study using computed tomography and conventional posteroanterior radiography was performed on 27 patients with mesothelioma and 13 patients with advanced asbestosis. The major pathologic features of both asbestosis and mesothelioma were well demonstrated by both modalities; computed tomography demonstrated the findings more frequently and in greater detail. No distinguishing features could be established based on configuration and size of the lesion. Many pleural plaques associated with advanced asbestosis were large and irregular and resembled those associated with mesothelioma. However, nodular involvement of the pleural fissures, pleural effusion, and ipsilateral volume loss with a fixed mediastinum were features predominating in mesothelioma. Growth determination of the plaques associated with asbestosis may be of minimal value since such plaques also undergo growth due to active inflammatory changes

  20. Improving limited-projection-angle fluorescence molecular tomography using a co-registered x-ray computed tomography scan.

    Science.gov (United States)

    Radrich, Karin; Ale, Angelique; Ermolayev, Vladimir; Ntziachristos, Vasilis

    2012-12-01

    We examine the improvement in imaging performance, such as axial resolution and signal localization, when employing limited-projection-angle fluorescence molecular tomography (FMT) together with x-ray computed tomography (XCT) measurements versus stand-alone FMT. For this purpose, we employed living mice, bearing a spontaneous lung tumor model, and imaged them with FMT and XCT under identical geometrical conditions using fluorescent probes for cancer targeting. The XCT data was employed, herein, as structural prior information to guide the FMT reconstruction. Gold standard images were provided by fluorescence images of mouse cryoslices, providing the ground truth in fluorescence bio-distribution. Upon comparison of FMT images versus images reconstructed using hybrid FMT and XCT data, we demonstrate marked improvements in image accuracy. This work relates to currently disseminated FMT systems, using limited projection scans, and can be employed to enhance their performance.