  1. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  2. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  4. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  5. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  7. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  9. Computed tomography

    International Nuclear Information System (INIS)

    Boyd, D.P.

    1989-01-01

    This paper reports on computed tomographic (CT) scanning which has improved computer-assisted imaging modalities for radiologic diagnosis. The advantage of this modality is its ability to image thin cross-sectional planes of the body, thus uncovering density information in three dimensions without tissue superposition problems. Because this enables vastly superior imaging of soft tissues in the brain and body, CT scanning was immediately successful and continues to grow in importance as improvements are made in speed, resolution, and cost efficiency. CT scanners are used for general purposes, and the more advanced machines are generally preferred in large hospitals, where volume and variety of usage justifies the cost. For imaging in the abdomen, a scanner with a rapid speed is preferred because peristalsis, involuntary motion of the diaphram, and even cardiac motion are present and can significantly degrade image quality. When contrast media is used in imaging to demonstrate scanner, immediate review of images, and multiformat hardcopy production. A second console is reserved for the radiologist to read images and perform the several types of image analysis that are available. Since CT images contain quantitative information in terms of density values and contours of organs, quantitation of volumes, areas, and masses is possible. This is accomplished with region-of- interest methods, which involve the electronic outlining of the selected region of the television display monitor with a trackball-controlled cursor. In addition, various image- processing options, such as edge enhancement (for viewing fine details of edges) or smoothing filters (for enhancing the detectability of low-contrast lesions) are useful tools

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  11. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  14. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  15. Effective dose range for dental cone beam computed tomography scanners

    International Nuclear Information System (INIS)

    Pauwels, Ruben; Beinsberger, Jilke; Collaert, Bruno; Theodorakou, Chrysoula; Rogers, Jessica; Walker, Anne; Cockmartin, Lesley; Bosmans, Hilde; Jacobs, Reinhilde; Bogaerts, Ria; Horner, Keith

    2012-01-01

    Objective: To estimate the absorbed organ dose and effective dose for a wide range of cone beam computed tomography scanners, using different exposure protocols and geometries. Materials and methods: Two Alderson Radiation Therapy anthropomorphic phantoms were loaded with LiF detectors (TLD-100 and TLD-100H) which were evenly distributed throughout the head and neck, covering all radiosensitive organs. Measurements were performed on 14 CBCT devices: 3D Accuitomo 170, Galileos Comfort, i-CAT Next Generation, Iluma Elite, Kodak 9000 3D, Kodak 9500, NewTom VG, NewTom VGi, Pax-Uni3D, Picasso Trio, ProMax 3D, Scanora 3D, SkyView, Veraviewepocs 3D. Effective dose was calculated using the ICRP 103 (2007) tissue weighting factors. Results: Effective dose ranged between 19 and 368 μSv. The largest contributions to the effective dose were from the remainder tissues (37%), salivary glands (24%), and thyroid gland (21%). For all organs, there was a wide range of measured values apparent, due to differences in exposure factors, diameter and height of the primary beam, and positioning of the beam relative to the radiosensitive organs. Conclusions: The effective dose for different CBCT devices showed a 20-fold range. The results show that a distinction is needed between small-, medium-, and large-field CBCT scanners and protocols, as they are applied to different indication groups, the dose received being strongly related to field size. Furthermore, the dose should always be considered relative to technical and diagnostic image quality, seeing that image quality requirements also differ for patient groups. The results from the current study indicate that the optimisation of dose should be performed by an appropriate selection of exposure parameters and field size, depending on the diagnostic requirements.

  16. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung

    2001-01-01

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  17. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  19. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  20. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  3. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  4. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  14. Effect of computed tomography noise and tissue heterogeneity on cerebral blood flow determination by xenon-enhanced computed tomography

    International Nuclear Information System (INIS)

    Good, W.F.; Gur, D.

    1987-01-01

    The errors associated with derivation of cerebral blood flow values by the xenon-enhanced computed tomography (CT) method have been evaluated as a function of tissue heterogeneity and CT noise. The results of this study indicate that CT noise introduces large errors in the derived flow value when data for a single, unprocessed voxel are used for this purpose. CT noise increases the derived flow values in a systematic way. Tissue heterogeneity results in a systematic error which lowers the derived flow values. Errors due to both parameters are computed for typical and extreme conditions

  15. Mycosis fungoides: Positron emission tomography/computed tomography in staging and monitoring the effect of therapy

    International Nuclear Information System (INIS)

    D’Souza, Maria Mathew; D’Souza, Paschal; Sharma, Rajnish; Jaimini, Abhinav; Mondal, Anupam

    2015-01-01

    A 58-year-old woman, diagnosed as a case of mycosis fungoides (MF), underwent [18F]-fluoro-D-glucose positron emission tomography/computed tomography (FDG PET/CT) examination. The study revealed intense FDG uptake in a large ulceroproliferative right thigh lesion, indurated plaques in the chest wall and left thigh, along with multiple sites of cutaneous involvement, axillary and inguinal lymphadenopathy. The patient underwent chemotherapy with CHOP regimen, radiotherapy for the right thigh lesion, along with topical corticosteroids and emollients for the disseminated cutaneous involvement. Repeat [18F]-FDG PET/CT study performed a year later, showed near complete disease regression specifically of the ulceroproliferative lesion and indurated cutaneous plaques, no change in lymphadenopathy, and a subtle diffuse progression of the remaining cutaneous lesions. A multidisciplinary approach to the diagnosis, staging and treatment of MF has long been suggested for optimizing outcomes from management of patients with this disease. This case highlights the potential role of incorporating PET/CT as a single modality imaging technique in the staging and assessment of response to therapy

  16. Effective doses to patients undergoing thoracic computed tomography examinations.

    Science.gov (United States)

    Huda, W; Scalzetti, E M; Roskopf, M

    2000-05-01

    The purpose of this study was to investigate how x-ray technique factors and effective doses vary with patient size in chest CT examinations. Technique factors (kVp, mAs, section thickness, and number of sections) were recorded for 44 patients who underwent a routine chest CT examination. Patient weights were recorded together with dimensions and mean Hounsfield unit values obtained from representative axial CT images. The total mass of directly irradiated patient was modeled as a cylinder of water to permit the computation of the mean patient dose and total energy imparted for each chest CT examination. Computed values of energy imparted during the chest CT examination were converted into effective doses taking into account the patient weight. Patient weights ranged from 4.5 to 127 kg, and half the patients in this study were children under 18 years of age. All scans were performed at 120 kVp with a 1 s scan time. The selected tube current showed no correlation with patient weight (r2=0.06), indicating that chest CT examination protocols do not take into account for the size of the patient. Energy imparted increased with increasing patient weight, with values of energy imparted for 10 and 70 kg patients being 85 and 310 mJ, respectively. The effective dose showed an inverse correlation with increasing patient weight, however, with values of effective dose for 10 and 70 kg patients being 9.6 and 5.4 mSv, respectively. Current CT technique factors (kVp/mAs) used to perform chest CT examinations result in relatively high patient doses, which could be reduced by adjusting technique factors based on patient size.

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  1. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  2. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  3. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  6. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  7. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  10. Aerosolized intranasal midazolam for safe and effective sedation for quality computed tomography imaging in infants and children.

    Science.gov (United States)

    Mekitarian Filho, Eduardo; de Carvalho, Werther Brunow; Gilio, Alfredo Elias; Robinson, Fay; Mason, Keira P

    2013-10-01

    This pilot study introduces the aerosolized route for midazolam as an option for infant and pediatric sedation for computed tomography imaging. This technique produced predictable and effective sedation for quality computed tomography imaging studies with minimal artifact and no significant adverse events. Copyright © 2013 Mosby, Inc. All rights reserved.

  11. Positron computed tomography with fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Hervouet, T.; Kraeber-Bodere, F.; Lamy, T.; Le Gouil, S.; Devillers, A.; Bodet-Milin, C.; Ansquer, C.; Cheze-le Rest, C.; Metges, J.P.; Teyton, P.; Lozach, P.; Volant, A.; Bizais, Y.; Visvikis, D.; Morel, O.; Girault, S.; Soulie, P.; Dupoiron, D.; Berthelot, C.; Lorimier, G.; Jallet, P.; Garin, E.; Prigent, F.; Lesimple, T.; Barge, M.L.; Rousseau, C.; Devillers, A.; Bernard, A.M.; Bouriel, C.; Bridji, B.; Resche, R.; Banayan, S.; Claret, M.; Ninet, J.; Janier, M.; Billotey, C.; Garin, E.; Devillers, A.; Becker, S.; Lecloirec, J.; Boucher, E.; Raoul, J.L.; Rolland, V.; Oudoux, A.; Valette, F.; Dupas, B.; Moreau, P.; Champion, L.; Anract, P.; Wartski, M.; Laurence, V.; Goldwasser, F.; Pecking, A.P.; Alberini, J.L.; Brillouet, S.; Caselles, O.; Allal, B.; Zerdoud, S.; Gansel, M.G.; Thomas, F.; Dierrickx, L.; Delord, J.P.; Marchand, C.; Resche, I.; Mahe, M.A.

    2006-01-01

    Several oral communications present the interest of positron computed tomography with fluorodeoxyglucose in the detection of cancers, or for the follow up of cancers treatments in order to detect early possible relapses.PET FDG is also used to optimize the definition of target volume in order to avoid side effects and to get a better control of the illness. (N.C.)

  12. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  13. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  14. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  15. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  16. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  17. Effects of computer tomography on diagnosis of neurological and neurosurgical diseases

    International Nuclear Information System (INIS)

    Katzner, E.

    1981-01-01

    Computer tomography is presently the primary procedure for correct diagnosis of many neurological and neurosurgical diseases. Other expensive and riskier diagnostic methods have become superfluous. Selective and clearly indicated application of the undoubtedly expensive computer tomography ultimately spares unnecessary costs for hospitalization and less conclusive examination methods. Wheras the indications in the craniocerebral region can now be considered confirmed, spinal computer tomography is still in the development stage. With certain indications, e.g. in prolapsed lumbar intervertebral disk, a similar performance to that of CT can be obtained with myelography, so that the latter method is likely to be superceded by computer tomography. (orig.) [de

  18. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  19. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  20. High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography.

    Science.gov (United States)

    Lell, Michael M; May, Matthias; Deak, Paul; Alibek, Sedat; Kuefner, Michael; Kuettner, Axel; Köhler, Henrik; Achenbach, Stephan; Uder, Michael; Radkow, Tanja

    2011-02-01

    computed tomography (CT) is considered the method of choice in thoracic imaging for a variety of indications. Sedation is usually necessary to enable CT and to avoid deterioration of image quality because of patient movement in small children. We evaluated a new, subsecond high-pitch scan mode (HPM), which obviates the need of sedation and to hold the breath. a total of 60 patients were included in this study. 30 patients (mean age, 14 ± 17 month; range, 0-55 month) were examined with a dual source CT system in an HPM. Scan parameters were as follows: pitch = 3.0, 128 × 0.6 mm slice acquisition, 0.28 seconds gantry rotation time, ref. mAs adapted to the body weight (50-100 mAs) at 80 kV. Images were reconstructed with a slice thickness of 0.75 mm. None of the children was sedated for the CT examination and no breathing instructions were given. Image quality was assessed focusing on motion artifacts and delineation of the vascular structures and lung parenchyma. Thirty patients (mean age, 15 ± 17 month; range, 0-55 month) were examined under sedation on 2 different CT systems (10-slice CT, n = 18; 64-slice CT, n = 13 patients) in conventional pitch mode (CPM). Dose values were calculated from the dose length product provided in the patient protocol/dose reports, Monte Carlo simulations were performed to assess dose distribution for CPM and HPM. all scans were performed without complications. Image quality was superior with HPM, because of a significant reduction in motion artifacts, as compared to CPM with 10- and 64-slice CT. In the control group, artifacts were encountered at the level of the diaphragm (n = 30; 100%), the borders of the heart (n = 30; 100%), and the ribs (n = 20; 67%) and spine (n = 6; 20%), whereas motion artifacts were detected in the HPM-group only in 6 patients in the lung parenchyma next to the diaphragm or the heart (P detector width and pitch-value. high-pitch chest CT is a robust method to provide highest image quality making sedation

  1. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  2. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  3. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  4. Effect of Novel Amplitude/Phase Binning Algorithm on Commercial Four-Dimensional Computed Tomography Quality

    International Nuclear Information System (INIS)

    Olsen, Jeffrey R.; Lu Wei; Hubenschmidt, James P.; Nystrom, Michelle M.; Klahr, Paul; Bradley, Jeffrey D.; Low, Daniel A.; Parikh, Parag J.

    2008-01-01

    Purpose: Respiratory motion is a significant source of anatomic uncertainty in radiotherapy planning and can result in errors of portal size and the subsequent radiation dose. Although four-dimensional computed tomography allows for more accurate analysis of the respiratory cycle, breathing irregularities during data acquisition can cause considerable image distortions. The aim of this study was to examine the effect of respiratory irregularities on four-dimensional computed tomography, and to evaluate a novel image reconstruction algorithm using percentile-based tagging of the respiratory cycle. Methods and Materials: Respiratory-correlated helical computed tomography scans were acquired for 11 consecutive patients. The inspiration and expiration data sets were reconstructed using the default phase-based method, as well as a novel respiration percentile-based method with patient-specific metrics to define the ranges of the reconstruction. The image output was analyzed in a blinded fashion for the phase- and percentile-based reconstructions to determine the prevalence and severity of the image artifacts. Results: The percentile-based algorithm resulted in a significant reduction in artifact severity compared with the phase-based algorithm, although the overall artifact prevalence did not differ between the two algorithms. The magnitude of differences in respiratory tag placement between the phase- and percentile-based algorithms correlated with the presence of image artifacts. Conclusion: The results of our study have indicated that our novel four-dimensional computed tomography reconstruction method could be useful in detecting clinically relevant image distortions that might otherwise go unnoticed and to reduce the image distortion associated with some respiratory irregularities. Additional work is necessary to assess the clinical impact on areas of possible irregular breathing

  5. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  6. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  7. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  8. Effects of Respiration-Averaged Computed Tomography on Positron Emission Tomography/Computed Tomography Quantification and its Potential Impact on Gross Tumor Volume Delineation

    International Nuclear Information System (INIS)

    Chi, Pai-Chun Melinda; Mawlawi, Osama; Luo Dershan; Liao Zhongxing; Macapinlac, Homer A.; Pan Tinsu

    2008-01-01

    Purpose: Patient respiratory motion can cause image artifacts in positron emission tomography (PET) from PET/computed tomography (CT) and change the quantification of PET for thoracic patients. In this study, respiration-averaged CT (ACT) was used to remove the artifacts, and the changes in standardized uptake value (SUV) and gross tumor volume (GTV) were quantified. Methods and Materials: We incorporated the ACT acquisition in a PET/CT session for 216 lung patients, generating two PET/CT data sets for each patient. The first data set (PET HCT /HCT) contained the clinical PET/CT in which PET was attenuation corrected with a helical CT (HCT). The second data set (PET ACT /ACT) contained the PET/CT in which PET was corrected with ACT. We quantified the differences between the two datasets in image alignment, maximum SUV (SUV max ), and GTV contours. Results: Of the patients, 68% demonstrated respiratory artifacts in the PET HCT , and for all patients the artifact was removed or reduced in the corresponding PET ACT . The impact of respiration artifact was the worst for lesions less than 50 cm 3 and located below the dome of the diaphragm. For lesions in this group, the mean SUV max difference, GTV volume change, shift in GTV centroid location, and concordance index were 21%, 154%, 2.4 mm, and 0.61, respectively. Conclusion: This study benchmarked the differences between the PET data with and without artifacts. It is important to pay attention to the potential existence of these artifacts during GTV contouring, as such artifacts may increase the uncertainties in the lesion volume and the centroid location

  9. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  10. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  11. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

    Science.gov (United States)

    Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-03-01

    This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

  12. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Fairbairn, I.A.

    1984-01-01

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  13. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  14. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  15. Concept of effective atomic number and effective mass density in dual-energy X-ray computed tomography

    International Nuclear Information System (INIS)

    Bonnin, Anne; Duvauchelle, Philippe; Kaftandjian, Valérie; Ponard, Pascal

    2014-01-01

    This paper focuses on dual-energy X-ray computed tomography and especially the decomposition of the measured attenuation coefficient in a mass density and atomic number basis. In particular, the concept of effective atomic number is discussed. Although the atomic number is well defined for chemical elements, the definition of an effective atomic number for any compound is not an easy task. After reviewing different definitions available in literature, a definition related to the method of measurement and X-ray energy, is suggested. A new concept of effective mass density is then introduced in order to characterize material from dual-energy computed tomography. Finally, this new concept and definition are applied on a simulated case, focusing on explosives identification in luggage

  16. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  18. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  4. Regional Diagnostic Reference Levels and Collective Effective Doses from Computed Tomography (CT) Scanners in India

    International Nuclear Information System (INIS)

    Livingstone, R.S.; Dinakaran, P.M.

    2011-01-01

    Diagnostic examinations performed using computed tomography (CT) are on the increase, and the use of this modality needs to be monitored periodically. The aim of this study was to formulate regional diagnostic reference levels (DRLs) and assess collective effective doses from CT scanners in Tamil Nadu, India. In-site CT dose measurements were performed for 127 CT scanners in Tamil Nadu as a part of the Atomic Energy Regulatory Board (AERB) funded project for a period of two years. Regional DRLs were formulated at third quartile level for three CT protocols such as thorax, abdomen and pelvis and were found to be 557 mGy.cm, 521 mGy.cm and 294 mGy.cm, respectively. The collective effective dose in Tamil Nadu was found to be 14.93 man Sv per day. (author)

  5. Evaluation of effective regurgitant orifice area of mitral valvular regurgitation by multislice cardiac computed tomography

    International Nuclear Information System (INIS)

    Vural, M.; Ucar, O.; Celebi, O.O.; Cicekcioglu, H.; Durmaz, H.A.; Selvi, N.A.; Koparal, S.; Aydogdu, S.

    2010-01-01

    The purpose of our study was to assess the diagnostic accuracy of multislice computed tomography (MSCT) for the identification and quantification of mitral valve regurgitation in comparison with transthoracic echocardiography (TTE). Twenty-six patients (15 females, 11 males with a mean age of 44.6±14.1 years) who were in follow-up with the diagnosis of mitral regurgitation and those who were referred for MSCT were enrolled. MSCT results were compared with TTE measurements. The mean effective mitral regurgitant orifice area at MSCT was 23.1±13.0 mm 2 and at echocardiography was 24.4±16.0mm 2 . Bland-Altman analysis showed good agreement between the two imaging methods. MSCT provides reliable and good results for the evaluation of mitral regurgitation. (author)

  6. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  7. How does nose blowing effect the computed tomography of paranasal sinuses in chronic sinusitis?

    Energy Technology Data Exchange (ETDEWEB)

    Savranlar, Ahmet; Uzun, Lokman; Ugur, Mehmet Birol; Mahmutyazicioglu, Kamran; Ozer, Tulay; Gundogdu, Sadi

    2005-02-01

    Objective: Our aim was to determine whether inward or outward movement of the secretions in the paranasal sinuses due to nose blowing after nasal decongestion has any effect on the paranasal sinus computed tomography (CT) images in patients with sinusitis and to asses whether nose blowing may result in misdiagnosis or overdiagnosis in radiological evaluation of sinusitis. Materials and methods: Twenty-four patients with chronic sinusitis were evaluated in an academic tertiary care hospital and data were collected prospectively. After coronal sinus computed tomography scans were performed at 100 mA setting which was half the value of the standard radiation dose suggested by the manufacturer, topical decongestion was applied to each nostril followed by nose blowing 10 min later. Sinus CT scans were then repeated at the same setting. We evaluated the mucosal thickness of medial, lateral, superior and inferior maxillary and frontal sinus walls and the maximal thickness in anterior ethmoidal cells. The measurements prior to and following nose blowing were compared with Wilcoxon signed ranks test. The obtained images were also staged using Lund-McKay staging system separately and the scores were compared with Student's t-test. Results: We observed a tendency towards reduction in mucosal thickness after nose blowing. There were statistically significant differences between maxillary sinus inferior wall and frontal sinus inferior wall mucosal thickness values prior to and after nose blowing. The difference however was very small, about 0.5 mm in magnitude and Lund-McKay score did not change in any of the patients after nose blowing. Conclusion: Nose blowing and topical nasal decongestion does not have any effect on the diagnostic accuracy of sinus CT in chronic sinusitis patients.

  8. How does nose blowing effect the computed tomography of paranasal sinuses in chronic sinusitis?

    International Nuclear Information System (INIS)

    Savranlar, Ahmet; Uzun, Lokman; Ugur, Mehmet Birol; Mahmutyazicioglu, Kamran; Ozer, Tulay; Gundogdu, Sadi

    2005-01-01

    Objective: Our aim was to determine whether inward or outward movement of the secretions in the paranasal sinuses due to nose blowing after nasal decongestion has any effect on the paranasal sinus computed tomography (CT) images in patients with sinusitis and to asses whether nose blowing may result in misdiagnosis or overdiagnosis in radiological evaluation of sinusitis. Materials and methods: Twenty-four patients with chronic sinusitis were evaluated in an academic tertiary care hospital and data were collected prospectively. After coronal sinus computed tomography scans were performed at 100 mA setting which was half the value of the standard radiation dose suggested by the manufacturer, topical decongestion was applied to each nostril followed by nose blowing 10 min later. Sinus CT scans were then repeated at the same setting. We evaluated the mucosal thickness of medial, lateral, superior and inferior maxillary and frontal sinus walls and the maximal thickness in anterior ethmoidal cells. The measurements prior to and following nose blowing were compared with Wilcoxon signed ranks test. The obtained images were also staged using Lund-McKay staging system separately and the scores were compared with Student's t-test. Results: We observed a tendency towards reduction in mucosal thickness after nose blowing. There were statistically significant differences between maxillary sinus inferior wall and frontal sinus inferior wall mucosal thickness values prior to and after nose blowing. The difference however was very small, about 0.5 mm in magnitude and Lund-McKay score did not change in any of the patients after nose blowing. Conclusion: Nose blowing and topical nasal decongestion does not have any effect on the diagnostic accuracy of sinus CT in chronic sinusitis patients

  9. Use of Monte Carlo simulation software for calculating effective dose in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gomes B, W. O., E-mail: wilsonottobatista@gmail.com [Instituto Federal da Bahia, Rua Emidio dos Santos s/n, Barbalho 40301-015, Salvador de Bahia (Brazil)

    2016-10-15

    This study aimed to develop a geometry of irradiation applicable to the software PCXMC and the consequent calculation of effective dose in applications of the Computed Tomography Cone Beam (CBCT). We evaluated two different CBCT equipment s for dental applications: Care stream Cs 9000 3-dimensional tomograph; i-CAT and GENDEX GXCB-500. Initially characterize each protocol measuring the surface kerma input and the product kerma air-area, P{sub KA}, with solid state detectors RADCAL and PTW transmission chamber. Then we introduce the technical parameters of each preset protocols and geometric conditions in the PCXMC software to obtain the values of effective dose. The calculated effective dose is within the range of 9.0 to 15.7 μSv for 3-dimensional computer 9000 Cs; within the range 44.5 to 89 μSv for GXCB-500 equipment and in the range of 62-111 μSv for equipment Classical i-CAT. These values were compared with results obtained dosimetry using TLD implanted in anthropomorphic phantom and are considered consistent. Os effective dose results are very sensitive to the geometry of radiation (beam position in mathematical phantom). This factor translates to a factor of fragility software usage. But it is very useful to get quick answers to regarding process optimization tool conclusions protocols. We conclude that use software PCXMC Monte Carlo simulation is useful assessment protocols for CBCT tests in dental applications. (Author)

  10. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  11. Effects of Hyperthyroidism on Coronary Artery Disease: A Computed Tomography Angiography Study.

    Science.gov (United States)

    Beyer, Christoph; Plank, Fabian; Friedrich, Guy; Wildauer, Matthias; Feuchtner, Gudrun

    2017-10-01

    Changes in thyroid hormone concentration can negatively affect the cardiovascular system. Subclinical hyperthyroidism has been linked to an increase of cardiovascular heart disease, however, clinical effects and significance are still uncertain. Therefore, we analyzed coronary computed tomography angiographies of patients with overt and subclinical hyperthyroidism for quantitative parameters and plaque morphology. Seven hundred forty-four (47.1% female) patients who underwent coronary computed tomography angiography were stratified into 3 groups: 51 patients with overt, 74 patients with subclinical hyperthyroidism, and 619 patients with euthyroidism. Analysis included grades of stenosis (no stenosis = 0, mild 70%) and plaque types (noncalcified, mixed, and calcified), segment involvement score (SIS), noncalcified SIS, and high-risk plaque features (napkin ring sign, low attenuation plaque, spotty calcifications, positive remodelling). Patients with overt and subclinical hyperthyroidism had more high-grade stenoses (39.2% vs 37.8% vs 24.2%; P = 0.007) and a higher coronary calcium score (456.5 vs 199.5 vs 155.9; P hyperthyroidism, followed by those with subclinical hyperthyroidism, had the most high-risk plaque features: napkin ring (21.6% vs 9.5% vs 6.0%, P hyperthyroid patients. Patients with subclinical and overt hyperthyroidism showed more high-grade coronary stenoses, plaque burden, and high-risk plaque features than patients with euthyroidism, which indicates that an increase of thyroid hormones might lead to coronary vascular degeneration and plaque instability. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  12. The effect of iterative reconstruction on computed tomography assessment of emphysema, air trapping and airway dimensions

    NARCIS (Netherlands)

    Mets, Onno M.; Willemink, Martin J.; de Kort, Freek P. L.; Mol, Christian P.; Leiner, Tim; Oudkerk, Matthijs; Prokop, Mathias; de Jong, Pim A.

    2012-01-01

    To determine the influence of iterative reconstruction (IR) on quantitative computed tomography (CT) measurements of emphysema, air trapping, and airway wall and lumen dimensions, compared to filtered back-projection (FBP). Inspiratory and expiratory chest CTs of 75 patients (37 male, 38 female;

  13. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ... ray beam follows a spiral path. A special computer program processes this large volume of data to ...

  19. The effect of repeated freeze-thaw cycles on human muscle tissue visualized by postmortem computed tomography (PMCT)

    NARCIS (Netherlands)

    Klop, Anthony C.; Vester, Marloes E. M.; Colman, Kerri L.; Ruijter, Jan M.; van Rijn, Rick R.; Oostra, Roelof-Jan

    2017-01-01

    The aim of this study was to determine whether effects of repetitive freeze-thaw cycles, with various thawing temperatures, on human muscle tissue can be quantified using postmortem computed tomography (PMCT) technology. An additional objective was to determine the preferred thawing temperature for

  20. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  1. Contrast timing in computed tomography: Effect of different contrast media concentrations on bolus geometry

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Jost, Gregor; Seidensticker, Peter; Kuhl, Christiane; Pietsch, Hubertus

    2012-01-01

    Objective: To assess the effect of low-osmolar, monomeric contrast media with different iodine concentrations on bolus shape in aortic CT angiography. Materials and methods: Repeated sequential computed tomography scanning of the descending aorta of eight beagle dogs (5 male, 12.7 ± 3.1 kg) was performed without table movement with a standardized CT scan protocol. Iopromide 300 (300 mg I/mL), iopromide 370 (370 mg I/mL) and iomeprol 400 (400 mg I/mL) were administered via a foreleg vein with an identical iodine delivery rate of 1.2 g I/s and a total iodine dose of 300 mg I/kg body weight. Time-enhancement curves were computed and analyzed. Results: Iopromide 300 showed the highest peak enhancement (445.2 ± 89.1 HU), steepest up-slope (104.2 ± 17.5 HU/s) and smallest full width at half maximum (FWHM; 5.8 ± 1.0 s). Peak enhancement, duration of FWHM, enhancement at FWHM and up-slope differed significantly between iopromide 300 and iomeprol 400 (p 0.05). Conclusions: Low viscous iopromide 300 results in a better defined bolus with a significantly higher peak enhancement, steeper up-slope and smaller FWHM when compared to iomeprol 400. These characteristics potentially affect contrast timing.

  2. Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography

    International Nuclear Information System (INIS)

    Sato, Jiro; Akahane, Masaaki; Inano, Sachiko; Terasaki, Mariko; Akai, Hiroyuki; Katsura, Masaki; Matsuda, Izuru; Kunimatsu, Akira; Ohtomo, Kuni

    2012-01-01

    The purpose of this study was to assess the effects of dose and adaptive statistical iterative reconstruction (ASIR) on image quality of pulmonary computed tomography (CT). Inflated and fixed porcine lungs were scanned with a 64-slice CT system at 10, 20, 40 and 400 mAs. Using automatic exposure control, 40 mAs was chosen as standard dose. Scan data were reconstructed with filtered back projection (FBP) and ASIR. Image pairs were obtained by factorial combination of images at a selected level. Using a 21-point scale, three experienced radiologists independently rated differences in quality between adjacently displayed paired images for image noise, image sharpness and conspicuity of tiny nodules. A subjective quality score (SQS) for each image was computed based on Anderson's functional measurement theory. The standard deviation was recorded as a quantitative noise measurement. At all doses examined, SQSs improved with ASIR for all evaluation items. No significant differences were noted between the SQSs for 40%-ASIR images obtained at 20 mAs and those for FBP images at 40 mAs. Compared to the FBP algorithm, ASIR for lung CT can enable an approximately 50% dose reduction from the standard dose while preserving visualization of small structures. (author)

  3. Effectiveness of computed tomography attenuation values in characterization of pericardial effusion.

    Science.gov (United States)

    Çetin, Mehmet Serkan; Özcan Çetin, Elif Hande; Özdemir, Mustafa; Topaloğlu, Serkan; Aras, Dursun; Temizhan, Ahmet; Aydoğdu, Sinan

    2017-04-01

    The aim of this study was to evaluate the effectiveness of computed tomography (CT) attenuation values in the characterization of pericardial effusion. This study consisted of 96 patients with pericardial effusion who underwent pericardiocentesis. For further diagnostic evaluation of pericardial effusion, all the patients were assessed by thorax CT. CT attenuation values were measured from at least 5 different areas of pericardial fluid by specifying the largest region of interest. The average of these measurements was computed and considered as the CT attenuation value of the patient. The patients were classified into two groups: patients with transudative pericardial effusion and those with exudative pericardial effusion. CT attenuation values were significantly higher in patients with exudative pericardial effusion than in those with transudative pericardial effusion [14.85±10.7 Hounsfield unit (HU) vs. 1.13±4.3 HU, peffusion. In addition, a cut-off value of 6.5 HU had 71.4% sensitivity and 72.3% specificity for the prediction of cardiac tamponade. In patients with pericardial effusion, CT attenuation values seem to be correlated with the characterization parameters of the fluid and may distinguish exudative pericardial effusion from transudative pericardial effusion. This parameter was also found to be a predictor of cardiac tamponade. CT attenuation values can be a useful tool in the clinical evaluation of patients with pericardial effusion.

  4. Micro-computed tomography characterization of tissue engineering scaffolds: effects of pixel size and rotation step.

    Science.gov (United States)

    Cengiz, Ibrahim Fatih; Oliveira, Joaquim Miguel; Reis, Rui L

    2017-08-01

    Quantitative assessment of micro-structure of materials is of key importance in many fields including tissue engineering, biology, and dentistry. Micro-computed tomography (µ-CT) is an intensively used non-destructive technique. However, the acquisition parameters such as pixel size and rotation step may have significant effects on the obtained results. In this study, a set of tissue engineering scaffolds including examples of natural and synthetic polymers, and ceramics were analyzed. We comprehensively compared the quantitative results of µ-CT characterization using 15 acquisition scenarios that differ in the combination of the pixel size and rotation step. The results showed that the acquisition parameters could statistically significantly affect the quantified mean porosity, mean pore size, and mean wall thickness of the scaffolds. The effects are also practically important since the differences can be as high as 24% regarding the mean porosity in average, and 19.5 h and 166 GB regarding the characterization time and data storage per sample with a relatively small volume. This study showed in a quantitative manner the effects of such a wide range of acquisition scenarios on the final data, as well as the characterization time and data storage per sample. Herein, a clear picture of the effects of the pixel size and rotation step on the results is provided which can notably be useful to refine the practice of µ-CT characterization of scaffolds and economize the related resources.

  5. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  6. A new practical model of testes shield: the effectiveness during abdominopelvic computed tomography.

    Science.gov (United States)

    Sancaktutar, Ahmet Ali; Bozkurt, Yaşar; Önder, Hakan; Söylemez, Haluk; Atar, Murat; Penbegül, Necmettin; Ziypak, Tevfik; Tekbaş, Güven; Tepeler, Abdülkadir

    2012-01-01

    The goal of our prospective study was to measure the effect of a new standard model male gonad shield on the testicular radiation exposure during routine abdominopelvic computed tomography (CT). Two hundred male patients who underwent upper abdominal and pelvic CT examinations were included in our study. To prepare the testes shield (TS), 2 No. 8 fluoroscopy radiation-protection gloves made of bismuth (0.35 mm lead equivalent) were used. These gloves were invaginated into one another and their fingers were turned inside out. Scrotums of all patients were pushed into these lead-containing gloves. Upper abdominal CT (n = 6), pelvic CT (n = 9), and abdominopelvic scanning (n = 185) were performed. Immediately after the CT examinations and at postprocedural day 1, the scrotal examinations were repeated. None of the patients exhibited scrotal laceration, edema, eruption, erythema, tenderness, or pain. During the CT examinations, 22 patients (11%) felt unrest because of their exposed genital regions, without any adverse effect on the procedure. Dosimetric measurements of radioactivity inside the TS (dosimeter I) and outside it (dosimeter II) were 6.8 and 69.00 mSv, respectively. Accordingly, the TS we used in our study reduced the radiation exposure of the testes by 90.2% (10.1 times). We think that the use of this radioprotective TS during radiological diagnostic and therapeutic procedures is an appropriate approach from both a medical and legal perspective. Therefore, we recommend this userfriendly, practical, low-cost, and effective TS for all radiologic procedures.

  7. Emission computed tomography

    International Nuclear Information System (INIS)

    Phelps, M.E.

    1977-01-01

    Although there are many common aspects to x-ray transmission and radionuclide emission (ECT) computerized tomography, there are added difficulties and a number of particular factors which form the basis of ECT. The relationship between the physical factors, system design, methodologic approach and assumptions of ECT is discussed. The instrumentation design and application strategies in ECT at this time are diverse and in a rapid stage of development. The approaches are divided into two major categories of Single Photon Counting (SPC) employing scanner and camera concepts with radionuclides of 99 /sup m/Tc, 201 Tl, 123 I etc., and Annihilation Coincidence Detection (ACD) of positron-emitting radionuclides. Six systems in the former and ten systems in the latter category, with examples of typical studies, illustrate the different approaches

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... diagnose sinusitis . evaluate sinuses that are filled with fluid or thickened sinus membranes . detect the presence of ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... of the Sinuses? CT is usually the first test ordered when a sinus tumor is suspected. If ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... to reduce the risk of an allergic reaction. These medications must be taken 12 hours prior to ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to reduce the risk of an allergic reaction. These medications must be taken 12 hours prior to ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... to you, revolve around you during the imaging process. You will be alone in the exam room ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... cause blurring of the images and degrade the quality of the examination the same way that it ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... artifacts on the images. This loss of image quality can resemble the blurring seen on a photograph ...

  10. Whole-body positron emission tomography using fluorodeoxyglucose for staging of lymphoma: effectiveness and comparison with computed tomography

    International Nuclear Information System (INIS)

    Stumpe, K.D.M.; Urbinelli, M.; Steinert, H.C.; Glanzmann, C.; Buck, A.; Schulthess, G.K. von

    1998-01-01

    The purpose of this study was to evaluate whole-body positron emission tomography (WB-PET) as a staging modality in Hodgkin's disease (HD) and non-Hodgkin lymphoma (NHL) and to compare it with computed tomography (CT) in a retrospective study. Seventy-one WB-PET studies using fluorodeoxyglucose (FDG) and 49 CT examinations were performed in 19 women and 31 men. Transaxial images were acquired and reformatted coronally and sagittally in PET. CT sections were obtained from the skull base to the pelvic floor. The written reports of the imaging data were compared with a reference standard constructed on the basis of all the data on the individual patients, including clinical follow-up of at least 6 months. The sensitivity and specificity of PET were, respectively, 86% and 96% for HD (n=53), and 89% and 100% for NHL (n=18). For CT sensitivity and specificity were 81% and 41% for HD (n=33) and 86% and 67% for NHL (n=16). Differences between PET and CT sensitivities were not significant, while in HD there was a significant difference in the specificity of PET and CT examinations, mainly because CT was unable to distinguish between active or recurrent disease and residual scar tissue after therapy. FDG tumour uptake was found in high- as well as low-grade NHL patients. In conclusion, PET appears to be highly sensitive and specific for staging of lymphoma. It is at least as sensitive as CT, and more specific, particularly in patients undergoing restaging, where a well-recognized diagnostic dilemma in CT is the presence of a post-therapeutic residual mass. (orig.)

  11. Effects of four instruments on coronal pre-enlargement by using cone beam computed tomography.

    Science.gov (United States)

    Sanfelice, Cintia Mussoline; da Costa, Fernanda Botega; Reis Só, Marcus Vinícius; Vier-Pelisser, Fabiana; Souza Bier, Carlos Alexandre; Grecca, Fabiana Soares

    2010-05-01

    This ex vivo study used cone beam computed tomography to evaluate the amount of dentin removal from the distal wall of the mesial canal of human mandibular first molars caused by 4 instruments used to flare the cervical third. Thirty-two mesial roots were divided into 4 groups prepared by using ProTaper, K3, Gates-Glidden, or LA Axxess. The dentin thickness of the distal cervical wall of mesial canals was measured before and after the preparation by using computed tomography and Adobe Photoshop software. There was no statistically significant difference between the study groups (P > 05). All the instruments used for cervical preparation seemed to be safe and did not damage the dentin structure of the distal wall of mesial root canals of mandibular molars. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Reducing image noise in computed tomography (CT) colonography: effect of an integrated circuit CT detector.

    Science.gov (United States)

    Liu, Yu; Leng, Shuai; Michalak, Gregory J; Vrieze, Thomas J; Duan, Xinhui; Qu, Mingliang; Shiung, Maria M; McCollough, Cynthia H; Fletcher, Joel G

    2014-01-01

    To investigate whether the integrated circuit (IC) detector results in reduced noise in computed tomography (CT) colonography (CTC). Three hundred sixty-six consecutive patients underwent clinically indicated CTC using the same CT scanner system, except for a difference in CT detectors (IC or conventional). Image noise, patient size, and scanner radiation output (volume CT dose index) were quantitatively compared between patient cohorts using each detector system, with separate comparisons for the abdomen and pelvis. For the abdomen and pelvis, despite significantly larger patient sizes in the IC detector cohort (both P 0.18). Based on the observed image noise reduction, radiation dose could alternatively be reduced by approximately 20% to result in similar levels of image noise. Computed tomography colonography images acquired using the IC detector had significantly lower noise than images acquired using the conventional detector. This noise reduction can permit further radiation dose reduction in CTC.

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... information about radiation dose. There always is a risk of complications from general anesthesia or sedation. Every measure will be taken to ... in X-Ray and CT Exams Contrast Materials Anesthesia Safety Children and Radiation Safety ... (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) ...

  14. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  15. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  17. Laryngopyocele: signs on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nazaroglu, Hasan E-mail: hnazarog@dicle.edu.tr; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual.

  18. Laryngopyocele: signs on computed tomography

    International Nuclear Information System (INIS)

    Nazaroglu, Hasan; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual

  19. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  20. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  1. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  2. Cost-effectiveness of routine computed tomography in the evaluation of idiopathic unilateral vocal fold paralysis.

    Science.gov (United States)

    Hojjat, Houmehr; Svider, Peter F; Folbe, Adam J; Raza, Syed N; Carron, Michael A; Shkoukani, Mahdi A; Merati, Albert L; Mayerhoff, Ross M

    2017-02-01

    To evaluate the cost-effectiveness of routine computed tomography (CT) in individuals with unilateral vocal fold paralysis (UVFP) STUDY DESIGN: Health Economics Decision Tree Analysis METHODS: A decision tree was constructed to determine the incremental cost-effectiveness ratio (ICER) of CT imaging in UVFP patients. Univariate sensitivity analysis was utilized to calculate what the probability of having an etiology of the paralysis discovered would have to be to make CT with contrast more cost-effective than no imaging. We used two studies examining findings in UVFP patients. The decision pathways were utilizing CT neck with intravenous contrast after diagnostic laryngoscopy versus laryngoscopy alone. The probability of detecting an etiology for UVFP and associated costs were extracted to construct the decision tree. The only incorrect diagnosis was missing a mass in the no-imaging decision branch, which rendered an effectiveness of 0. The ICER of using CT was $3,306, below most acceptable willingness-to-pay (WTP) thresholds. Additionally, univariate sensitivity analysis indicated that at the WTP threshold of $30,000, obtaining CT imaging was the most cost-effective choice when the probability of having a lesion was above 1.7%. Multivariate probabilistic sensitivity analysis with Monte Carlo simulations also showed that at the WTP of $30,000, CT scanning is more cost-effective, with 99.5% certainty. Particularly in the current healthcare environment characterized by increasing consciousness of utilization defensive medicine, economic evaluations represent evidence-based findings that can be employed to facilitate appropriate decision making and enhance physician-patient communication. This economic evaluation strongly supports obtaining CT imaging in patients with newly diagnosed UVFP. 2c. Laryngoscope, 2016 127:440-444, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Estimation of effective doses in pediatric X-ray computed tomography examination.

    Science.gov (United States)

    Obara, Hideki; Takahashi, Midori; Kudou, Kazuya; Mariya, Yasushi; Takai, Yoshihiro; Kashiwakura, Ikuo

    2017-11-01

    X-ray computed tomography (CT) images are used for diagnostic and therapeutic purposes in various medical disciplines. In Japan, the number of facilities that own diagnostic CT equipment, the number of CT examinations and the number of CT scanners increased by ~1.4-fold between 2005 and 2011. CT operators (medical radiological technologists, medical physicists and physicians) must understand the effective doses for examinations at their own institutions and carefully approach each examination. In addition, the patients undergoing the examination (as well as his/her family) must understand the effective dose of each examination in the context of the cumulative dose. In the present study, the numbers of pediatric patients (aged 0-5 years) and total patients who underwent CT at Hirosaki University Hospital (Hirosaki, Japan) between January 2011 and December 2013 were surveyed, and effective doses administered to children aged 0, 1 and 5 years were evaluated. Age- and region-specific conversion factors and dose-length products obtained from the CT scanner were used to estimate the effective doses. The numbers of CT examinations performed in 2011, 2012 and 2013 were 16,662, 17,491 and 17,649, respectively, of which 613 (1.2%) of the overall total involved children aged 0-5 years. The estimated effective doses per examination to children aged 0, 1 and 5 years were 6.3±4.8, 4.9±3.8 and 2.7±3.0 mSv, respectively. This large variation was attributed to several factors associated with scan methods and ranges in actual setting. In conclusion, the requirement for individual patient prospective exposure management systems and estimations of low-dose radiation exposure should be considered in light of the harmful effects of exposure.

  4. Effectiveness of a worksheet for diagnosing postmortem computed tomography in emergency departments

    International Nuclear Information System (INIS)

    Takahashi, Naoya; Higuchi, Takeshi; Shiotani, Motoi; Satou, Suguru; Hirose, Yasuo

    2011-01-01

    The aim of this study was to evaluate the effectiveness of a worksheet for diagnosing postmortem computed tomography (PMCT) in emergency departments (EDs). A total of 49 cases of clinically diagnosed nontraumatic deaths in the ED who underwent total body PMCT were enrolled. PMCT images were prospectively evaluated by four radiologists: two radiologists with 1.5 and 3.5 years of residency and two board-certified radiologists with >20 years of experience. Readers were independently instructed to detect and interpret findings with reference to fatal findings, postmortem features, changes caused by cardiopulmonary resuscitation, and other pathological findings according to a worksheet that was composed of the possible findings previously reported. Agreement on detection and interpretation of findings between each reader was measured using Cohen's kappa coefficients. For the detection of findings, there was substantial agreement among the four readers (kappa>0.60, P 0.60, P<0.0001) and near-substantial (kappa=0.60, P<0.0001) agreement in the interpretation of the finding. Results of our study suggest equivalency on diagnosing PMCT regardless of the reader's level of experience. We conclude that the worksheet is useful for diagnosing PMCT in emergency departments. (author)

  5. Effect of intravenous Buscopan on colonic distention during computed tomography colonography

    International Nuclear Information System (INIS)

    Behrens, C.; Stevenson, G.; Eddy, R.; Mathieson, J.

    2008-01-01

    This study was designed to assess whether spasmolytic drugs are helpful in computed tomography colonography (CTC), as there is conflict in the literature. We assessed retrospectively in a blinded fashion colonic distention in 149 individuals, one-half of whom had intravenous (IV) Buscopan during CTC. Colonic segments (n = 1788) were analyzed by 2 observers, and allocated to one of 4 grades of the distention. We also recorded the presence and severity of diverticular disease. Buscopan increased the likelihood of optimal distention by an OR of 5 when considering individual colonic segments from ascending colon to sigmoid, with little effect on rectum or cecum. Considering the colon as a whole, the OR of optimal distention occurring throughout the entire colon was 7.9 times greater with Buscopan than without. In the sigmoid colon, Buscopan had a significantly greater impact on obtaining optimal distention in those with diverticulosis than in those without. Buscopan increases the probability of obtaining optimal distention during CTC, especially in the sigmoid colon in diverticular disease. Buscopan is likely to improve polyp conspicuity and patient comfort, and to reduce both the examination time during and the interpretation time We recommend routine use of Buscopan during CTC. (author)

  6. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  7. The effect of decreasing computed tomography dosage on radiostereometric analysis (RSA) accuracy at the glenohumeral joint.

    Science.gov (United States)

    Fox, Anne-Marie V; Kedgley, Angela E; Lalone, Emily A; Johnson, James A; Athwal, George S; Jenkyn, Thomas R

    2011-11-10

    Standard, beaded radiostereometric analysis (RSA) and markerless RSA often use computed tomography (CT) scans to create three-dimensional (3D) bone models. However, ethical concerns exist due to risks associated with CT radiation exposure. Therefore, the aim of this study was to investigate the effect of decreasing CT dosage on RSA accuracy. Four cadaveric shoulder specimens were scanned using a normal-dose CT protocol and two low-dose protocols, where the dosage was decreased by 89% and 98%. 3D computer models of the humerus and scapula were created using each CT protocol. Bi-planar fluoroscopy was used to image five different static glenohumeral positions and two dynamic glenohumeral movements, of which a total of five static and four dynamic poses were selected for analysis. For standard RSA, negligible differences were found in bead (0.21±0.31mm) and bony landmark (2.31±1.90mm) locations when the CT dosage was decreased by 98% (p-values>0.167). For markerless RSA kinematic results, excellent agreement was found between the normal-dose and lowest-dose protocol, with all Spearman rank correlation coefficients greater than 0.95. Average root mean squared errors of 1.04±0.68mm and 2.42±0.81° were also found at this reduced dosage for static positions. In summary, CT dosage can be markedly reduced when performing shoulder RSA to minimize the risks of radiation exposure. Standard RSA accuracy was negligibly affected by the 98% CT dose reduction and for markerless RSA, the benefits of decreasing CT dosage to the subject outweigh the introduced errors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Regorafenib effects on human colon carcinoma xenografts monitored by dynamic contrast-enhanced computed tomography with immunohistochemical validation.

    Directory of Open Access Journals (Sweden)

    Clemens C Cyran

    Full Text Available To investigate dynamic contrast-enhanced computed tomography for monitoring the effects of regorafenib on experimental colon carcinomas in rats by quantitative assessments of tumor microcirculation parameters with immunohistochemical validation.Colon carcinoma xenografts (HT-29 implanted subcutaneously in female athymic rats (n = 15 were imaged at baseline and after a one-week treatment with regorafenib by dynamic contrast-enhanced computed tomography (128-slice dual-source computed tomography. The therapy group (n = 7 received regorafenib daily (10 mg/kg bodyweight. Quantitative parameters of tumor microcirculation (plasma flow, mL/100 mL/min, endothelial permeability (PS, mL/100 mL/min, and tumor vascularity (plasma volume, % were calculated using a 2-compartment uptake model. Dynamic contrast-enhanced computed tomography parameters were validated with immunohistochemical assessments of tumor microvascular density (CD-31, tumor cell apoptosis (TUNEL, and proliferation (Ki-67.Regorafenib suppressed tumor vascularity (15.7±5.3 to 5.5±3.5%; p<0.05 and tumor perfusion (12.8±2.3 to 8.8±2.9 mL/100 mL/min; p = 0.063. Significantly lower microvascular density was observed in the therapy group (CD-31; 48±10 vs. 113±25, p<0.05. In regorafenib-treated tumors, significantly more apoptotic cells (TUNEL; 11844±2927 vs. 5097±3463, p<0.05 were observed. Dynamic contrast-enhanced computed tomography tumor perfusion and tumor vascularity correlated significantly (p<0.05 with microvascular density (CD-31; r = 0.84 and 0.66 and inversely with apoptosis (TUNEL; r = -0.66 and -0.71.Regorafenib significantly suppressed tumor vascularity (plasma volume quantified by dynamic contrast-enhanced computed tomography in experimental colon carcinomas in rats with good-to-moderate correlations to an immunohistochemical gold standard. Tumor response biomarkers assessed by dynamic contrast-enhanced computed tomography may be a promising future

  9. Cost-effectiveness of implementing computed tomography screening for lung cancer in Taiwan.

    Science.gov (United States)

    Yang, Szu-Chun; Lai, Wu-Wei; Lin, Chien-Chung; Su, Wu-Chou; Ku, Li-Jung; Hwang, Jing-Shiang; Wang, Jung-Der

    2017-06-01

    A screening program for lung cancer requires more empirical evidence. Based on the experience of the National Lung Screening Trial (NLST), we developed a method to adjust lead-time bias and quality-of-life changes for estimating the cost-effectiveness of implementing computed tomography (CT) screening in Taiwan. The target population was high-risk (≥30 pack-years) smokers between 55 and 75 years of age. From a nation-wide, 13-year follow-up cohort, we estimated quality-adjusted life expectancy (QALE), loss-of-QALE, and lifetime healthcare expenditures per case of lung cancer stratified by pathology and stage. Cumulative stage distributions for CT-screening and no-screening were assumed equal to those for CT-screening and radiography-screening in the NLST to estimate the savings of loss-of-QALE and additional costs of lifetime healthcare expenditures after CT screening. Costs attributable to screen-negative subjects, false-positive cases and radiation-induced lung cancer were included to obtain the incremental cost-effectiveness ratio from the public payer's perspective. The incremental costs were US$22,755 per person. After dividing this by savings of loss-of-QALE (1.16 quality-adjusted life year (QALY)), the incremental cost-effectiveness ratio was US$19,683 per QALY. This ratio would fall to US$10,947 per QALY if the stage distribution for CT-screening was the same as that of screen-detected cancers in the NELSON trial. Low-dose CT screening for lung cancer among high-risk smokers would be cost-effective in Taiwan. As only about 5% of our women are smokers, future research is necessary to identify the high-risk groups among non-smokers and increase the coverage. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... may increase the risk of an unusual adverse effect. Women should always inform their physician and the ... to urinate; however, this is actually a contrast effect and subsides quickly. When you enter the CT ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... may increase the risk of an unusual adverse effect. The radiologist also should know if you have ... to urinate; however, this is actually a contrast effect and subsides quickly. When you enter the CT ...

  12. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  13. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... conditions may increase the risk of an unusual adverse effect. The radiologist also should know if you have ... CT scanning may eliminate the need for exploratory surgery and surgical ... immediate side effects. Risks There is always a slight chance of ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... conditions may increase the risk of an unusual adverse effect. Women should always inform their physician and the ... CT scanning may eliminate the need for exploratory surgery and surgical biopsy. ... immediate side effects. Risks There is always a slight chance of ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... dye," your doctor may prescribe medications (usually a steroid) to reduce the risk of an allergic reaction. ... may increase the risk of an unusual adverse effect. Women should always inform their physician and the ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... dye," your doctor may prescribe medications (usually a steroid) to reduce the risk of an allergic reaction. ... may increase the risk of an unusual adverse effect. The radiologist also should know if you have ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the nasal cavity and sinuses. plan for surgery by defining anatomy. top of page How should ... can help plan the safest and most effective surgery. CT of the sinuses is now widely available ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... may increase the risk of an unusual adverse effect. The radiologist also should know if you have ... the scanner and monitors your examination in direct visual contact and usually with the ability to hear ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to remove hearing aids and removable dental work. Women will be asked to remove bras containing metal ... increase the risk of an unusual adverse effect. Women should always inform their physician and the CT ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... in CT scans should have no immediate side effects. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... in CT scans should have no immediate side effects. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... about tumors of the nasal cavity and sinuses. plan for surgery by defining anatomy. top of page ... for sinusitis. CT of the sinuses can help plan the safest and most effective surgery. CT of ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits A CT scan is one of the ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... or other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may increase the risk of an unusual adverse effect. Women should always inform their physician and the CT ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may increase the risk of an unusual adverse effect. Women should always inform their physician and the CT ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may increase the risk of an unusual adverse effect. The ... any disorder of the heart, kidneys or thyroid gland , or if you have ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... can help plan the safest and most effective surgery. CT of the sinuses is now widely available and is performed in a relatively short time, especially when compared to magnetic resonance imaging (MRI). CT scanning is painless, noninvasive and ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... about tumors of the nasal cavity and sinuses. plan for surgery by defining anatomy. top of page How should ... for sinusitis. CT of the sinuses can help plan the safest and most effective surgery. CT of the sinuses is now widely available ...

  17. Industrial applications of computer tomography

    International Nuclear Information System (INIS)

    Sheng Kanglong; Qiang Yujun; Yang Fujia

    1992-01-01

    Industrial computer tomography (CT) and its application is a rapidly developing field of high technology. CT systems have been playing important roles in nondestructive testing (NDT) of products and equipment for a number of industries. Recently, the technique has advanced into the area of industrial process control, bringing even greater benefit to mankind. The basic principles and typical structure of an industrial CT system Descriptions are given of some successful CT systems for either NDT application or process control purposes

  18. Computed tomography of projectile injuries

    International Nuclear Information System (INIS)

    Jeffery, A.J.; Rutty, G.N.; Robinson, C.; Morgan, B.

    2008-01-01

    Computed tomography (CT) is a gold standard in clinical imaging but forensic professions have been slow to embrace radiological advances. Forensic applications of CT are now exponentially expanding, replacing other imaging methods. As post-mortem cross-sectional imaging increases, radiologists will fall under increasing pressure to interpret complex forensic cases involving both living and deceased patients. This review presents a wide variety of weapon and projectile types aiding interpretation of projectile injuries both in forensic and clinical practice

  19. Computed tomography in osteoid osteoma

    International Nuclear Information System (INIS)

    Vicens, J.L.; Aubspin, D.; Buchon, R.; Schoenenberger, P.; Flageat, J.

    1989-01-01

    Four cases of suspected osteoid osteoma were evaluated by computed tomography (CT). The role of CT was related, as a key diagnostic tool: radionuclide imaging is helpful in directing subsequent CT scans, which allows the study of complex anatomical sites (spine) or the analysis of atypical lesions (invisible nidus, sclerosis or lytic lesions, double nidus...). CT provides the surgeon with the exact location and extent of the lesion, and thus, CT may allow a more limited surgical resection of the involved bone [fr

  20. Cumulative effective dose associated with computed tomography examinations in adolescent trauma patients.

    Science.gov (United States)

    Choi, Seung Joon; Kim, Eun Young; Kim, Hyung Sik; Choi, Hye-Young; Cho, Jinseong; Yang, Hyuk Jun; Chung, Yong Eun

    2014-07-01

    The aims of this study were to analyze cumulative effective dose (cED) and to assess lifetime attributable risk (LAR) of cancer due to radiation exposure during computed tomography (CT) examinations in adolescent trauma patients. Between January 2010 and May 2011, the adolescent patients with trauma were enrolled in this study. Numbers of CT examinations and body regions examined were collated, and cEDs were calculated using dose-length product values and conversion factors. Lifetime attributable risk for cancer incidence and cancer-associated mortality were quantified based on the studies of survivors of the atomic bombs on Japan. Data were stratified according to severity of trauma: minor trauma, injury severity score of less than 16; and major trauma, injury severity score of 16 or greater. A total of 698 CT scans were obtained on the following regions of 484 adolescent patients: head CT, n = 647; rest of the body, n = 41; and thorax, n = 10. Mean cED per patient was 3.4 mSv, and mean LARs for cancer incidence and mortality were 0.05% and 0.02%, respectively. The majority of patients (98.4%) experienced minor trauma, and their mean cED and LARs for cancer incidence and mortality (3.0 mSv and 0.04% and 0.02%, respectively) were significantly lower than those of patients with major trauma (24.3 mSv and 0.31% and 0.15%, respectively, all P values trauma was found to be relatively low in adolescent patients. However, adolescent patients with major trauma were exposed to a substantial amount of radiation during multiple CT examinations.

  1. Detection of freeze-thaw weathering effect using X-ray micro computed tomography

    Science.gov (United States)

    Park, J.; Hyun, C.; Park, H.

    2011-12-01

    Physical weathering caused by repeated freeze-thaw action of water inside rock pores or cracks was artificially simulated in laboratory. The tests were conducted on three rock types, i.e. diorite, basalt, and tuff, which are the major rock types around King Sejong Station of Korea located in Barton Peninsula, King George Island, Antarctica. The temperature of freeze-thaw cycle was also set with simulated the air temperature of the station, i.e. the maximum temperature was + 10 °C and the minimum temperature was - 20 °C. Three cylindrical specimens composed of one for each rock type with 24.6 mm diameter and 14.5 ~ 17.7 mm length were prepared, and 2 mm diameter and 7 mm shallow depth hole was drilled on the center of the specimens. To exaggerate the effect of the freeze-thaw weathering, all tests were conducted under completely saturated condition. 50 cycles of the freeze-thaw test was carried, and X-ray micro computed tomography (CT) images of each rock specimen were obtained after every 10 cycles. Using X-ray micro CT images, 3D structure was rendered and pore and crack structures were extracted. The changes of porosity, absorption rate and pore and crack structure were detected. Porosity of all specimens was decreased linearly and absorption rate of all specimens was increased linearly as weathering processes; the pore connection and crack propagation was detected in 3D rendering pore and crack structure. The change of tuff specimen is the most remarkable among three rock types used in the research, because of its relatively high initial absorption rate and low strength. This work was supported by the National Research Foundation of Korea(NRF) grant funded by the Korea government(MEST) (No. 2011-0027520).

  2. Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography

    Science.gov (United States)

    Zappala, Susan; Helliwell, Jonathan R.; Tracy, Saoirse R.; Mairhofer, Stefan; Sturrock, Craig J.; Pridmore, Tony; Bennett, Malcolm; Mooney, Sacha J.

    2013-01-01

    X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i) highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii) to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii) present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy). However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored. PMID:23840640

  3. Effects of lithium on extraction socket healing in rats assessed with micro-computed tomography.

    Science.gov (United States)

    Zeng, Yun Ting; Fu, Bin; Tang, Guo Hua; Zhang, Lei; Qian, Yu Fen

    2013-09-01

    Lithium is an activator of β-catenin signaling and β-catenin plays an important role in regulating bone formation and remodeling. The purpose of this study was to investigate the effects of lithium on bone repair in tooth extraction sockets in rats. Twenty male Wistar rats were subjected to maxillary left second molar extraction. The animals received a daily injection of lithium chloride (LiCl) or the same dose of sodium chloride (NaCl) starting 7 days before tooth extraction until sacrifice 14 days after extraction. Rats were randomly divided into: (1) a pre-treated group that received LiCl injection from 7 days before to 3 days after tooth extraction; (2) a post-treated group that received LiCl injection starting 4 days after tooth extraction; (3) a continuously treated group that received LiCl injection for the entire 21 days; and (4) a control group that received NaCl injection only. The volume of new bone and the bone density in the extraction socket were quantified by micro-computed tomography. The percentage of new bone formation in the extraction socket was as follows: 63.2 ± 13.4% (pre-treated group), 53.9 ± 9.8% (post-treated), 23.8 ± 8.0% (continuously treated) and 37.5 ± 4.2% (control). The difference in percentage was statistically significant between each pair of groups. Pre- and post-treated groups also showed a significant increase in the density of new bone. Lithium enhances bone repair in extraction sockets when delivered before or after tooth extraction. Tooth extraction during lithium treatment may impair bone healing.

  4. Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality

    International Nuclear Information System (INIS)

    Habib Geryes, Bouchra; Calmon, Raphael; Boddaert, Nathalie; Khraiche, Diala; Bonnet, Damien; Raimondi, Francesca

    2016-01-01

    To assess the impact of different protocols on radiation dose and image quality for paediatric coronary computed tomography (cCT). From January-2012 to June-2014, 140 children who underwent cCT on a 64-slice scanner were included. Two consecutive changes in imaging protocols were performed: 1) the use of adaptive statistical iterative reconstruction (ASIR); 2) the optimization of acquisition parameters. Effective dose (ED) was calculated by conversion of the dose-length product. Image quality was assessed as excellent, good or with significant artefacts. Patients were divided in three age groups: 0-4, 5-7 and 8-18 years. The use of ASIR combined to the adjustment of scan settings allowed a reduction in the median ED of 58 %, 82 % and 85 % in 0-4, 5-7 and 8-18 years group, respectively (7.3 ± 1.4 vs 3.1 ± 0.7 mSv, 5.5 ± 1.6 vs 1 ± 1.9 mSv and 5.3 ± 5.0 vs 0.8 ± 2.0 mSv, all p < 0,05). Prospective protocol was used in 51 % of children. The reduction in radiation dose was not associated with reduction in diagnostic image quality as assessed by the frequency of coronary segments with excellent or good image quality (88 %). cCT can be obtained at very low radiation doses in children using ASIR, and prospective acquisition with optimized imaging parameters. (orig.)

  5. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  6. Computed tomography of the ossicles

    International Nuclear Information System (INIS)

    Chakeres, D.W.; Weider, D.J.

    1985-01-01

    Otologists and otolaryngologists have described in detail the disorders which are unique to the ossicles. However the anatomy and spectrum of pathology and anatomy of the ossicles are not familiar to most radiologists. Recent advances in computed tomography (CT) and a systematic approach to evaluation now allow accurate identification of even subtle abnormalities of the ossicles. We present the normal anatomy, ossicular abnormalities, and indications for computed tomographic study. Because of the greater diagnostic capability of CT, the radiologist's role has increased in evaluation and treatment planning of patients with suspected ossicular abnormalities. (orig.)

  7. Organ and effective doses in newborn patients during helical multislice computed tomography examination

    International Nuclear Information System (INIS)

    Staton, Robert J; Lee, Choonik; Lee, Choonsik; Williams, Matt D; Hintenlang, David E; Arreola, Manuel M; Williams, Jonathon L; Bolch, Wesley E

    2006-01-01

    In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used to model the patient anatomy was the revised ORNL newborn phantom by Han et al (2006 Health Phys.90 337). The tomographic phantom used in the study was that developed by Nipper et al (2002 Phys. Med. Biol. 47 3143) as recently revised by Staton et al (2006 Med. Phys. 33 3283). The stylized model was implemented within the MCNP5 radiation transport code, while the tomographic phantom was incorporated within the EGSnrc code. In both codes, the x-ray source was modelled as a fan beam originating from the focal spot at a fan angle of 52 0 and a focal-spot-to-axis distance of 57 cm. The helical path of the source was explicitly modelled based on variations in collimator setting (12 mm or 24 mm), detector pitch and scan length. Tube potentials of 80, 100 and 120 kVp were considered in this study. Beam profile data were acquired using radiological film measurements on a 16 cm PMMA phantom, which yielded effective beam widths of 14.7 mm and 26.8 mm for collimator settings of 12 mm and 24 mm, respectively. Values of absolute organ absorbed dose were determined via the use of normalization factors defined as the ratio of the CTDI 100 measured in-phantom and that determined by Monte Carlo simulation of the PMMA phantom and ion chamber. Across various technique factors, effective dose differences between the stylized and tomographic phantoms ranged from +2% to +9% for head exams, -4% to -2% for chest exams, +8% to +24% for abdominal exams, -16% to -12% for pelvic exams and -7% to 0% for chest-abdomen-pelvis (CAP) exams. In many cases, however, relatively close agreement in effective dose was accomplished at the expense of compensating errors in individual organ

  8. Organ and effective doses in newborn patients during helical multislice computed tomography examination

    Science.gov (United States)

    Staton, Robert J.; Lee, Choonik; Lee, Choonsik; Williams, Matt D.; Hintenlang, David E.; Arreola, Manuel M.; Williams, Jonathon L.; Bolch, Wesley E.

    2006-10-01

    In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used to model the patient anatomy was the revised ORNL newborn phantom by Han et al (2006 Health Phys.90 337). The tomographic phantom used in the study was that developed by Nipper et al (2002 Phys. Med. Biol. 47 3143) as recently revised by Staton et al (2006 Med. Phys. 33 3283). The stylized model was implemented within the MCNP5 radiation transport code, while the tomographic phantom was incorporated within the EGSnrc code. In both codes, the x-ray source was modelled as a fan beam originating from the focal spot at a fan angle of 52° and a focal-spot-to-axis distance of 57 cm. The helical path of the source was explicitly modelled based on variations in collimator setting (12 mm or 24 mm), detector pitch and scan length. Tube potentials of 80, 100 and 120 kVp were considered in this study. Beam profile data were acquired using radiological film measurements on a 16 cm PMMA phantom, which yielded effective beam widths of 14.7 mm and 26.8 mm for collimator settings of 12 mm and 24 mm, respectively. Values of absolute organ absorbed dose were determined via the use of normalization factors defined as the ratio of the CTDI100 measured in-phantom and that determined by Monte Carlo simulation of the PMMA phantom and ion chamber. Across various technique factors, effective dose differences between the stylized and tomographic phantoms ranged from +2% to +9% for head exams, -4% to -2% for chest exams, +8% to +24% for abdominal exams, -16% to -12% for pelvic exams and -7% to 0% for chest-abdomen-pelvis (CAP) exams. In many cases, however, relatively close agreement in effective dose was accomplished at the expense of compensating errors in individual organ

  9. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  10. The history of computed tomography

    International Nuclear Information System (INIS)

    Bull, J.

    1980-01-01

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ) [de

  11. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic. (orig.)

  12. Duodenal diverticulitis. computed tomography findings

    International Nuclear Information System (INIS)

    Sanchez, E.; Martin, S.; Garcia, J.; Dominguez, A.

    2001-01-01

    Duodenal diverticular occur very frequently among the general public. However, duodenal diverticulitis is a very uncommon clinical entity, the diagnosis of which requires radiological studies since the clinical signs cam mimic a great number of disease processes with different treatments. We present a case of duodenal diverticulitis in which the diagnosis according to ultrasound and computed tomography (CT) studies was confirmed intraoperatively. We also review the few cases of this entity reported in the literature. The CT findings are highly suggestive of duodenal diverticulitis given their similarity to those associated with diverticulitis at other sites. (Author) 5 refs,

  13. Mathematical foundations of computed tomography

    International Nuclear Information System (INIS)

    Smith, K.T.; Keinert, F.

    1985-01-01

    Along with a review of some of the mathematical foundations of computed tomography, the article contains new results on derivation of reconstruction formulas in a general setting encompassing all standard formulas; discussion and examples of the role of the point spread function with recipes for producing suitable ones; formulas for, and examples of, the reconstruction of certain functions of the attenuation coefficient, e.g., sharpened versions of it, some of them with the property that reconstruction at a point requires only the attenuation along rays meeting a small neighborhood of the point

  14. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  15. Brain metastases: computed tomography assessment

    International Nuclear Information System (INIS)

    Gordillo, Victoria; Yagual, Glenda; Vinueza, Clayreth

    1998-01-01

    Intracranial metastatic tumor is relatively frequent in patients with cancer from other origin. Its location and type of metastasis varies in relation to its linage from the primary tumor. And the sequence goes from the most frequent: lung and breast cancer, melanoma, GU tract, leukemia, GI tract, head and neck tumor. Computed tomography findings are extremely varied and non specific, so there are no radiologic characteristics even from the primary tumor. We reviewed 29 TC studies in the Radiology department of ION-SOLCA, from patients with diagnosis of brain metastasis, our findings showed the great variability in the radio-diagnosis imaging. (The author)

  16. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic

  17. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  18. Effect of expression of P-glycoprotein on technetium-99m methoxyisobutylisonitrile single photon emission computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Yasushi; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The expression of P-glycoprotein was investigated imunohistochemically in 26 brain tumor tissues and compared with the findings of technetium-99m methoxyisobutylisonitrile single photon emission computed tomography ({sup 99m}Tc-MIBI SPECT) to clarify the effect of P-glycoprotein on the diagnostic accuracy. P-glycoprotein labeling index of both tumor cells and vascular endothelial cells showed no clear relationship with the findings of {sup 99m}Tc-MIBI SPECT imaging. Expression of P-glycoprotein has no effect on the diagnostic accuracy of {sup 99m}Tc-MIBI SPECT. (author)

  19. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... applications. This thesis takes a systematic approach toward establishing quantitative understanding of conditions for sparse reconstruction to work well in CT. A general framework for analyzing sparse reconstruction methods in CT is introduced and two sets of computational tools are proposed: 1...... contributions to a general set of computational characterization tools. Thus, the thesis contributions help advance sparse reconstruction methods toward routine use in...

  20. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Accuracy in the Staging of Non-Small Cell Lung Cancer: Review and Cost-Effectiveness

    International Nuclear Information System (INIS)

    Gómez León, Nieves; Escalona, Sofía; Bandrés, Beatriz; Belda, Cristobal; Callejo, Daniel; Blasco, Juan Antonio

    2014-01-01

    Aim of the performed clinical study was to compare the accuracy and cost-effectiveness of PET/CT in the staging of non-small cell lung cancer (NSCLC). Material and Methods. Cross-sectional and prospective study including 103 patients with histologically confirmed NSCLC. All patients were examined using PET/CT with intravenous contrast medium. Those with disease stage ≤IIB underwent surgery (n = 40). Disease stage was confirmed based on histology results, which were compared with those of PET/CT and positron emission tomography (PET) and computed tomography (CT) separately. 63 patients classified with ≥IIIA disease stage by PET/CT did not undergo surgery. The cost-effectiveness of PET/CT for disease classification was examined using a decision tree analysis. Results. Compared with histology, the accuracy of PET/CT for disease staging has a positive predictive value of 80%, a negative predictive value of 95%, a sensitivity of 94%, and a specificity of 82%. For PET alone, these values are 53%, 66%, 60%, and 50%, whereas for CT alone they are 68%, 86%, 76%, and 72%, respectively. Incremental cost-effectiveness of PET/CT over CT alone was €17,412 quality-adjusted life-year (QALY). Conclusion. In our clinical study, PET/CT using intravenous contrast medium was an accurate and cost-effective method for staging of patients with NSCLC

  1. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Accuracy in the Staging of Non-Small Cell Lung Cancer: Review and Cost-Effectiveness

    International Nuclear Information System (INIS)

    Leon, N.G.; Bandrs, B.; Escalona, S.; Callejo, D.; Blasco, J.A.; Belda, C.; Blasco, J.A.

    2014-01-01

    Aim of the performed clinical study was to compare the accuracy and cost-effectiveness of PET/CT in the staging of non-small cell lung cancer (NSCLC). Material and Methods. Cross-sectional and prospective study including 103 patients with histologically confirmed NSCLC. All patients were examined using PET/CT with intravenous contrast medium. Those with disease stage ≤IIB underwent surgery (η=40). Disease stage was confirmed based on histology results, which were compared with those of PET/CT and positron emission tomography (PET) and computed tomography (CT) separately. 63 patients classified with ≥IIIA disease stage by PET/CT did not undergo surgery. The cost-effectiveness of PET/CT for disease classification was examined using a decision tree analysis. Results. Compared with histology, the accuracy of PET/CT for disease staging has a positive predictive value of 80%, a negative predictive value of 95%, a sensitivity of 94%, and a specificity of 82%. For PET alone, these values are 53%, 66%, 60%, and 50%, whereas for CT alone they are 68%, 86%, 76%, and 72%, respectively. Incremental cost-effectiveness of PET/CT over CT alone was €17,412 quality-adjusted life-year (QALY). Conclusion. In our clinical study, PET/CT using intravenous contrast medium was an accurate and cost-effective method for staging of patients with NSCLC

  2. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  3. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Isherwood, I.; Antoun, N.M.

    1984-01-01

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  4. Motion artifacts in computed tomography

    International Nuclear Information System (INIS)

    Yang, C.K.

    1979-01-01

    In the year 1972, the first Computed Tomography Scanner (or CT) was introduced and caused a revolution in the field of Diagnostic Radiology. A tomogram is a cross-sectional image of a three-dimensional object obtained through non-invasive measurements. The image that is presented is very similar to what would be seen if a thin cross-sectional slice of the patient was examined. In Computed Tomography, x-rays are passed through the body of a patient in many different directions and their attenuation is detected. By using some mathematical theorems, the attenuation information can be converted into the density of the patient along the x-ray path. Combined with modern sophisticated computer signal processing technology, a cross-sectional image can be generated and displayed on a TV monitor. Usually a good CT image relies on the patient not moving during the x-ray scanning. However, for some unconscious or severely ill patients, this is very difficult to achieve. Thus, the motion during the scan causes the so-called motion artifacts which distort the displayed image and sometimes these motion artifacts make diagnosis impossible. Today, to remove or avoid motion artifacts is one of the major efforts in developing new scanner systems. In this thesis, a better understanding of the motion artifacts problem in CT scaning is gained through computer simulations, real scanner experiments and theoretical analyses. The methods by which the distorted image can be improved are simulated also. In particular, it is assumed that perfect knowledge of the patient motion is known since this represents the theoretical limit on how well the distorted image can be improved

  5. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  6. Normalizing computed tomography data reconstructed with different filter kernels: effect on emphysema quantification

    International Nuclear Information System (INIS)

    Gallardo-Estrella, Leticia; Prokop, Mathias; Lynch, David A.; Stinson, Douglas; Zach, Jordan; Judy, Philip F.; Ginneken, Bram van; Rikxoort, Eva M. van

    2016-01-01

    To propose and evaluate a method to reduce variability in emphysema quantification among different computed tomography (CT) reconstructions by normalizing CT data reconstructed with varying kernels. We included 369 subjects from the COPDGene study. For each subject, spirometry and a chest CT reconstructed with two kernels were obtained using two different scanners. Normalization was performed by frequency band decomposition with hierarchical unsharp masking to standardize the energy in each band to a reference value. Emphysema scores (ES), the percentage of lung voxels below -950 HU, were computed before and after normalization. Bland-Altman analysis and correlation between ES and spirometry before and after normalization were compared. Two mixed cohorts, containing data from all scanners and kernels, were created to simulate heterogeneous acquisition parameters. The average difference in ES between kernels decreased for the scans obtained with both scanners after normalization (7.7 ± 2.7 to 0.3 ± 0.7; 7.2 ± 3.8 to -0.1 ± 0.5). Correlation coefficients between ES and FEV 1 , and FEV 1 /FVC increased significantly for the mixed cohorts. Normalization of chest CT data reduces variation in emphysema quantification due to reconstruction filters and improves correlation between ES and spirometry. (orig.)

  7. Application of ray tracing towards a correction for refracting effects in computed tomography with diffracting sources

    International Nuclear Information System (INIS)

    Andersen, A.H.

    1983-01-01

    Ray tracing methods are investigated in forward and inverse processes and applied for image restoration and resolution enhancement in computed tomography with diffracting sources. Within the geometrical optics approximation for a given refractive field, a mathematical model for the forward propagation and inverse reconstruction process is presented. For a finite set of rays in a discrete image representation, an algebraic reconstruction technique is derived which is analogous to the inverse process for a continuum of rays. The geometrical theory of diffraction is invoked to describe ray patterns arising from the introduction of object discontinuity surfaces. We have compared the performance of existing recursive ray tracing techniques for the reconstruction of objects exhibiting discontinuity boundaries. A novel ray tracing and reconstruction technique is presented which enjoys significant computational savings over traditional implementations incorporating tedious ray linking procedures. Simulation studies illustrate the macro-structural distortion and loss of fine resolution when ray refraction is unaccounted for. Restoration and resolution enhancement is achieved with a recursive ray tracing approach. Successful experimental studies with tissue equivalent phantoms are presented. The comparison of simulation and experimental results demonstrated the reasonable assumption of the geometrical optics approximation. Simulation results for larger refractive deviations are encouraging

  8. Normalizing computed tomography data reconstructed with different filter kernels: effect on emphysema quantification

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo-Estrella, Leticia; Prokop, Mathias [Radboud University Nijmegen Medical Center, Geert Grooteplein 10 (route 767), P.O. Box 9101, Nijmegen (766) (Netherlands); Lynch, David A.; Stinson, Douglas; Zach, Jordan [National Jewish Health, Denver, CO (United States); Judy, Philip F. [Brigham and Women' s Hospital, Boston, MA (United States); Ginneken, Bram van; Rikxoort, Eva M. van [Radboud University Nijmegen Medical Center, Geert Grooteplein 10 (route 767), P.O. Box 9101, Nijmegen (766) (Netherlands); Fraunhofer MEVIS, Bremen (Germany)

    2016-02-15

    To propose and evaluate a method to reduce variability in emphysema quantification among different computed tomography (CT) reconstructions by normalizing CT data reconstructed with varying kernels. We included 369 subjects from the COPDGene study. For each subject, spirometry and a chest CT reconstructed with two kernels were obtained using two different scanners. Normalization was performed by frequency band decomposition with hierarchical unsharp masking to standardize the energy in each band to a reference value. Emphysema scores (ES), the percentage of lung voxels below -950 HU, were computed before and after normalization. Bland-Altman analysis and correlation between ES and spirometry before and after normalization were compared. Two mixed cohorts, containing data from all scanners and kernels, were created to simulate heterogeneous acquisition parameters. The average difference in ES between kernels decreased for the scans obtained with both scanners after normalization (7.7 ± 2.7 to 0.3 ± 0.7; 7.2 ± 3.8 to -0.1 ± 0.5). Correlation coefficients between ES and FEV{sub 1}, and FEV{sub 1}/FVC increased significantly for the mixed cohorts. Normalization of chest CT data reduces variation in emphysema quantification due to reconstruction filters and improves correlation between ES and spirometry. (orig.)

  9. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  10. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  11. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  12. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  13. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  14. The effect of inhaled corticosteroids on the development of emphysema in smokers assessed by annual computed tomography

    DEFF Research Database (Denmark)

    Shaker, Saher B; Dirksen, Asger; Ulrik, Charlotte S

    2009-01-01

    The objective was to evaluate the effect of inhaled corticosteroids on disease progression in smokers with moderate to severe chronic obstructive pulmonary disease (COPD), as assessed by annual computed tomography (CT) using lung density (LD) measurements. Two hundred and fifty-four current smokers...... (-54 mL) and placebo (-56 mL) (p = 0.89). Long-term budesonide inhalation shows a non-significant trend towards reducing the progression of emphysema as determined by the CT-derived 15th percentile lung density from annual CT scans in current smokers with moderate to severe COPD....

  15. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  16. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  17. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  18. Effect of contrast-enhanced computed tomography on diagnosis and management of acute abdomen in adults

    International Nuclear Information System (INIS)

    Tsushima, Yoshito; Yamada, Shuji; Aoki, Jun; Motojima, Teiji; Endo, Keigo

    2002-01-01

    AIM: To determine the impact of computed tomography (CT) on the diagnosis and treatment plan in patients with acute abdominal pain. MATERIALS AND METHODS: A prospective study was undertaken in 125 adult patients presenting with acute abdominal pain (74 men and 51 women; 40.2 ± 19.3 years; range, 18-92). Changes in diagnosis, gain in percentage diagnostic certainty and changes of treatment plan of the surgeons in the emergency department before and after CT were evaluated. Pre- and post-CT diagnoses were compared with the final diagnoses. RESULTS: CT findings changed the initial diagnosis in 40 (32.0%) patients. The diagnostic certainty was 58.3 ± 22.9% before CT, and its gain after CT was 21.9 ± 18.5 points (P < 0.0001). Post-CT diagnoses were consistent with the final diagnosis in 116 patients (92.8%), while pre-CT diagnoses were correct in 89 patients (71.2%; P < 0.0001). Initial treatment plans were changed in 31 (24.8%) patients after CT. In 57 (45.6%) patients, CT information changed diagnoses and/or treatment plans. No significant differences were observed in the diagnosis, diagnostic certainty and treatment plan among four surgeons. CONCLUSION: Contrast-enhanced CT frequently changed the clinical diagnoses with increased diagnostic certainty and the initial treatment plans. Tsushima, Y. et al. (2002)

  19. The effect of iterative reconstruction on computed tomography assessment of emphysema, air trapping and airway dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Mets, Onno M.; Willemink, Martin J.; Kort, Freek P.L. de; Leiner, Tim; Jong, Pim A. de [UMC Utrecht, Department of Radiology, P.O. Box 85500, GA, Utrecht (Netherlands); Mol, Christian P. [Utrecht University Medical Center, Image Sciences Institute, Utrecht (Netherlands); Oudkerk, Matthijs [Groningen University Medical Center, Department of Radiology, Groningen (Netherlands); Prokop, Mathias [Nijmegen University Medical Center, Department of Radiology, Nijmegen (Netherlands)

    2012-10-15

    To determine the influence of iterative reconstruction (IR) on quantitative computed tomography (CT) measurements of emphysema, air trapping, and airway wall and lumen dimensions, compared to filtered back-projection (FBP). Inspiratory and expiratory chest CTs of 75 patients (37 male, 38 female; mean age 64.0 {+-} 5.7 years) were reconstructed using FBP and IR. CT emphysema, CT air trapping and airway dimensions of a segmental bronchus were quantified using several commonly used quantification methods. The two algorithms were compared using the concordance correlation coefficient (p{sub c}) and Wilcoxon signed rank test. Only the E/I-ratio{sub MLD} as a measure of CT air trapping and airway dimensions showed no significant differences between the algorithms, whereas all CT emphysema and the other CT air trapping measures were significantly different at IR when compared to FBP (P < 0.001). The evaluated IR algorithm significantly influences quantitative CT measures in the assessment of emphysema and air trapping. However, the E/I-ratio{sub MLD} as a measure of CT air trapping, as well as the airway measurements, is unaffected by this reconstruction method. Quantitative CT of the lungs should be performed with careful attention to the CT protocol, especially when iterative reconstruction is introduced. (orig.)

  20. The effect of iterative reconstruction on computed tomography assessment of emphysema, air trapping and airway dimensions

    International Nuclear Information System (INIS)

    Mets, Onno M.; Willemink, Martin J.; Kort, Freek P.L. de; Leiner, Tim; Jong, Pim A. de; Mol, Christian P.; Oudkerk, Matthijs; Prokop, Mathias

    2012-01-01

    To determine the influence of iterative reconstruction (IR) on quantitative computed tomography (CT) measurements of emphysema, air trapping, and airway wall and lumen dimensions, compared to filtered back-projection (FBP). Inspiratory and expiratory chest CTs of 75 patients (37 male, 38 female; mean age 64.0 ± 5.7 years) were reconstructed using FBP and IR. CT emphysema, CT air trapping and airway dimensions of a segmental bronchus were quantified using several commonly used quantification methods. The two algorithms were compared using the concordance correlation coefficient (p c ) and Wilcoxon signed rank test. Only the E/I-ratio MLD as a measure of CT air trapping and airway dimensions showed no significant differences between the algorithms, whereas all CT emphysema and the other CT air trapping measures were significantly different at IR when compared to FBP (P MLD as a measure of CT air trapping, as well as the airway measurements, is unaffected by this reconstruction method. Quantitative CT of the lungs should be performed with careful attention to the CT protocol, especially when iterative reconstruction is introduced. (orig.)

  1. Effect of Hemoconcentration on Dural Sinus Computed Tomography Density in a Pediatric Population.

    Science.gov (United States)

    Yurttutan, Nursel; Kizildag, Betul; Sarica, Mehmet Akif; Baykara, Murat

    2016-10-01

    Unenhanced brain computed tomography (CT) is inexpensive, easily available, and the first-choice imaging modality for patients presenting with various neurologic symptoms. Venous thrombosis is not rare in childhood, but diagnosis can be difficult. In some cases, only denser vessels can be used to highlight an issue. The aim of this study was to retrospectively evaluate the relationship between X-ray attenuation and hemoconcentration in a pediatric population. This study enrolled 99 pediatric patients who had been referred radiology department for unenhanced brain CT. Images were retrospectively evaluated for measurement of dural sinus densities from four distinct dural sinus locations. Correlation between mean Hounsfield unit (HU) values and hemoglobin/hematocrit (Hb/Htc) levels, as well as age and gender were further analyzed. There was a strong correlation between mean HU and Hb levels (r = 0.411; standard deviation: 0.001) and also between mean HU and Htc levels (r = 0.393; p pediatric group. In conclusion, before deciding between a diagnosis of thrombosis and a determination of normal findings during an evaluation of unenhanced CT in a pediatric population, radiologists should consider complete blood count results as well as H:H ratios. Georg Thieme Verlag KG Stuttgart · New York.

  2. Computed tomography of splenic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey, R.B.; Laing, F.C.; Federle, M.P.; Goodman, P.C.

    1981-12-01

    Fifty patients with abdominal trauma and possible splenic injury were evaluated by computed tomography (CT). CT correctly diagnosed 21 of 22 surgically proved traumatic sesions of the spleen (96%). Twenty-seven patients had no evidence of splenic injury. This was confirmed at operation in 1 patient and clinical follow-up in 26. There were one false negative and one false positive. In 5 patients (10%), CT demonstrated other clinically significant lesions, including hepatic or renal lacerations in 3 and large retroperitoneal hematomas in 2. In adolescents and adults, CT is an accurate, noninvasive method of rapidly diagnosing splenic trauma and associated injuries. Further experience is needed to assess its usefulness in evaluating splenic injuries in infants and small children.

  3. Computed tomography of splenic trauma

    International Nuclear Information System (INIS)

    Jeffrey, R.B.; Laing, F.C.; Federle, M.P.; Goodman, P.C.

    1981-01-01

    Fifty patients with abdominal trauma and possible splenic injury were evaluated by computed tomography (CT). CT correctly diagnosed 21 of 22 surgically proved traumatic sesions of the spleen (96%). Twenty-seven patients had no evidence of splenic injury. This was confirmed at operation in 1 patient and clinical follow-up in 26. There were one false negative and one false positive. In 5 patients (10%), CT demonstrated other clinically significant lesions, including hepatic or renal lacerations in 3 and large retroperitoneal hematomas in 2. In adolescents and adults, CT is an accurate, noninvasive method of rapidly diagnosing splenic trauma and associated injuries. Further experience is needed to assess its usefulness in evaluating splenic injuries in infants and small children

  4. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  5. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  6. Computed tomography in hepatic trauma

    International Nuclear Information System (INIS)

    Moon, K.L. Jr.; Federle, M.P.

    1983-01-01

    Twenty-five patients with hepatic injury from blunt upper abdominal trauma were examined by computed tomography (CT). The spectrum of CT findings was recorded, and the size of the hepatic laceration and the associated hemoperitoneum were correlated with the mode of therapy used in each case (operative vs nonoperative). While the need for surgery correlated roughly with the size of the hepatic laceration, the size of the associated hemoperitoneum was an important modifying factor. Fifteen patients with hepatic lacerations but little or no hemoperitoneum were managed nonoperatively. CT seems to have significant advantages over hepatic scintigraphy, angiography, and diagnostic peritoneal lavage. By combining inforamtion on the clinical state of the patient and CT findings, therapy of hepatic injury can be individualized and the incidence of nontherapeutic laparotomies decreased

  7. Multi-detector computed tomography (MDCT imaging of cardiovascular effects of pulmonary embolism: What the radiologists need to know

    Directory of Open Access Journals (Sweden)

    Mohamed Aboul-fotouh E. Mourad

    2017-09-01

    Full Text Available Background: Patients with pulmonary embolism have high mortality and morbidity rate due to right heart failure and circulatory collapse leading to sudden death. Multi-detector computed tomography MDCT can efficiently evaluate the cardiovascular factors related to pulmonary embolism. Objectives: To evaluate the diagnostic accuracy of multi-detector computed tomography (MDCT in differentiation of between sever and non-severe pulmonary embolism groups depending on the associated cardiovascular parameters and create a simple reporting system. Patients & methods: Prospective study contained 145 patients diagnosed clinically pulmonary embolism. All patients were examined by combined electrocardiographically gated computed tomography pulmonary angiography-computed tomography venography (ECG-CTPA-CTV using certain imaging criteria in a systematic manner. Results: Our study revealed 95 and 55 non-severe and severe pulmonary embolism groups respectively. Many cardiovascular parameters related to pulmonary embolism shows significant p value and can differentiate between sever and non-severe pulmonary embolism patients include pulmonary artery diameter, intraventricular septum flattening, bowing, superior vena cava and Azygos vein diameters, right and left ventricular diameters. Conclusion: Multi-detector computed tomography (MDCT can be valuable to assess the severity of pulmonary embolism using the related cardiovascular parameters and leading the management strategy aim for best outcome. Keywords: Pulmonary embolism, MDCT, Cardiovascular, Computed tomography venography

  8. Computed tomography of cryogenic cells

    International Nuclear Information System (INIS)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-01-01

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions

  9. Basic principles of cone beam computed tomography.

    Science.gov (United States)

    Abramovitch, Kenneth; Rice, Dwight D

    2014-07-01

    At the end of the millennium, cone-beam computed tomography (CBCT) heralded a new dental technology for the next century. Owing to the dramatic and positive impact of CBCT on implant dentistry and orthognathic/orthodontic patient care, additional applications for this technology soon evolved. New software programs were developed to improve the applicability of, and access to, CBCT for dental patients. Improved, rapid, and cost-effective computer technology, combined with the ability of software engineers to develop multiple dental imaging applications for CBCT with broad diagnostic capability, have played a large part in the rapid incorporation of CBCT technology into dentistry. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Effectiveness of revascularization surgery evaluated by proton magnetic resonance spectroscopy and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Masaaki; Ueda, Shin; Hondo, Hideki; Matsumoto, Keizo; Harada, Masafumi [Tokushima Univ. (Japan). School of Medicine

    1996-08-01

    Proton magnetic resonance spectroscopy (MRS) and single photon emission computed tomography (SPECT) were used to evaluate chronic ischemic regions in 26 stroke patients before and 1, 3, and 6 months after revascularization surgery. The volume of interest for proton MRS was placed in an area including part of the frontal and temporal opercula, insular cortex, and basal ganglia. Twenty healthy volunteers served as controls for proton MRS. Patients were divided into three groups according to the preoperative proton MRS. Group A (n=12) had significantly lower N-acetylaspartate/choline (NAA/Cho) and N-acetylaspartate/creatine (NAA/Cr) ratios on the operative side compared to those on the contralateral side, and also lower than those in normal subjects. In seven patients in Group A, postoperative serial proton MRS demonstrated no recovery of these ratios on the operative side. However, proton MRS of the other five patients indicated gradual improvement in these ratios on the operative side at 3 to 6 months after surgery, and SPECT indicated an increase in cerebral blood flow on the operative side in four of these five patients. In Group B (n=9), proton MRS and SPECT showed no laterality before revascularization and no remarkable change during the postoperative course. In Group C (n=5), NAA/Cho or NAA/Cr decreased on the contralateral side preoperatively. Two patients showed fluctuating values of NAA/Cho or NAA/Cr during the postoperative period. Serial proton MRS and SPECT Studies may be useful for the evaluation of revascularization surgery on ischemic regions. The efficacy of revascularization surgery on the metabolism may appear gradually within 3-6 months. (author)

  11. X-ray computed tomography imaging method which is immune to beam hardening effect

    International Nuclear Information System (INIS)

    Kanno, Ikuo; Uesaka, Akio; Nomiya, Seiichiro; Onabe, Hideaki

    2009-01-01

    For the easy treatment of cancers, early finding of them is an important theme of study. X-ray transmission measurement and computed tomography (CT) are powerful tools for finding cancers. The x-ray CT shows cross sectional view of human body and is able to detect small cancers such as 1 cm in diameter. The CT, however, gives very high dose exposure to human body: some 10 to 1000 times higher dose exposure than the chest radiography. It is not possible to have medical health check using CT frequently, in view of both individual and public accumulated dose exposures. The authors have been working on the reduction of dose exposure in x-ray transmission measurements in case of detecting iodine contrast media, which concentrates in cancers. In our method, energy information of x-rays is employed: in conventional x-ray transmission measurements, x-rays are measured as current and the energy of each x-ray is ignored. The numbers of x-ray events, φ 1 and φ 2 , of which energies are lower and higher than the one of iodine K-edge, respectively, are used for the estimation of iodine thickness in cancers. Moreover, high energy x-rays, which are not sensitive to the absorption by iodine, are cut by a filter made of higher atomic number material than iodine. We call this method filtered x-ray energy subtraction (FIX-ES) method. This FIX-ES method was shown twice as sensitive to iodine than current measurement method. With the choice of filter thickness, minimum dose exposure in FIX-ES is 30% of that when white x-rays are employed. In the study described above, we concentrated on the observation of cancer part. In this study, a cancer phantom in normal tissue is observed by FIX-ES method. The results are compared with the ones obtained by current measurement method. (author)

  12. The effects of computed tomography with iterative reconstruction on solid pulmonary nodule volume quantification.

    Directory of Open Access Journals (Sweden)

    Martin J Willemink

    Full Text Available BACKGROUND: The objectives of this study were to evaluate the influence of iterative reconstruction (IR on pulmonary nodule volumetry with chest computed tomography (CT. METHODS: Twenty patients (12 women and 8 men, mean age 61.9, range 32-87 underwent evaluation of pulmonary nodules with a 64-slice CT-scanner. Data were reconstructed using filtered back projection (FBP and IR (Philips Healthcare, iDose(4-levels 2, 4 and 6 at similar radiation dose. Volumetric nodule measurements were performed with semi-automatic software on thin slice reconstructions. Only solid pulmonary nodules were measured, no additional selection criteria were used for the nature of nodules. For intra-observer and inter-observer variability, measurements were performed once by one observer and twice by another observer. Algorithms were compared using the concordance correlation-coefficient (pc and Friedman-test, and post-hoc analysis with the Wilcoxon-signed ranks-test with Bonferroni-correction (significance-level p<0.017. RESULTS: Seventy-eight nodules were present including 56 small nodules (volume<200 mm(3, diameter<8 mm and 22 large nodules (volume≥200 mm(3, diameter≥8 mm. No significant differences in measured pulmonary nodule volumes between FBP, iDose(4-levels 2, 4 and 6 were found in both small nodules and large nodules. FBP and iDose(4-levels 2, 4 and 6 were correlated with pc-values of 0.98 or higher for both small and large nodules. Pc-values of intra-observer and inter-observer variability were 0.98 or higher. CONCLUSIONS: Measurements of solid pulmonary nodule volume measured with standard-FBP were comparable with IR, regardless of the IR-level and no significant differences between measured volumes of both small and large solid nodules were found.

  13. Air trapping on computed tomography images of healthy individuals: effects of respiration and body mass index

    International Nuclear Information System (INIS)

    Hashimoto, M.; Tate, E.; Watarai, J.; Sasaki, M.

    2006-01-01

    Aim: To evaluate the relationships of changes in the lung area during respiration and of individual body mass index (BMI) to air trapping on expiratory computed tomography (CT) in young non-smoking adults of either gender. Methods: The volunteers were 10 women and 10 men (mean age 25.7 years) who were healthy lifelong non-smokers. We obtained both end-inspiratory and end-expiratory CT images at three levels: the upper, middle and lower lung. The ratio of cross-sectional lung area upon expiration to cross-sectional lung area upon inspiration (lung area ratio) was determined for each lung at each of the three levels. In cases showing air trapping, we calculated the percentage of area of air in relation to the total lung area in each section. BMI was calculated for each participant. Results: Air trapping was present in dependent areas of the lungs of 6 women and 5 men. The mean percentage of area of air trapped was statistically greater for men (9.8 ± 9.2%) than for women (4.9 ± 5.2%). The mean lung area ratio was 0.52 ± 0 14 among volunteers with air trapping (66 sections) and 0.69 ± 0.12 among those without air trapping (54 sections) (p < 0.001). At each lung level, the mean lung area ratio was greater in individuals with air trapping than in those without. Mean BMI was also greater in these people (p = 0.009). Conclusion: Change in the respiratory lung area and BMI contribute to development of air trapping

  14. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  15. Radiological protection in computed tomography and cone beam computed tomography.

    Science.gov (United States)

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Effects of chronic consumption of green tea on weight and body fat distribution of Wistar rats evaluated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Raso, Renata Attademo, E-mail: luizronaldoa@yahoo.com.br [Instituto de Ensino e Pesquisa da Santa Casa, Belo Horizonte, MG (Brazil); Paim, Rebecca Rodrigues Bergamaschini; Pinheiro, Sergio Veloso Brant; Tavares Junior, Wilson Campos; Vasconcellos, Leonardo de Souza; Alberti, Luiz Ronaldo [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2017-05-15

    Purpose: To evaluate the effects of chronic consumption of green tea on body weight and distribution of visceral fat by Computed tomography in female Wistar rats. Methods: Wistar rats were divided into control group (n = 5), which received water and feed ad libitum, and green tea group (n = 8), in which water has been replaced by green tea. The animals were weighed weekly and Computed Tomography was used at the beginning (1{sup st} week) and end (18{sup th} week) of the experiment for evaluating the distribution of visceral fat. The animals were followed for 18 weeks. Results: There was no significant difference in body weight between the groups. However, there was significant difference in visceral fat area. The green tea group had less visceral fat area at the end of the experiment, 3.67 ± 1.2 cm 2 , while the control group showed an area of 6.25 ± 2.2 cm (p = 0.00). Conclusions: Chronic consumption of green tea leads to decreased visceral adipose tissue area. (author)

  17. Effects of chronic consumption of green tea on weight and body fat distribution of Wistar rats evaluated by computed tomography

    International Nuclear Information System (INIS)

    Raso, Renata Attademo; Paim, Rebecca Rodrigues Bergamaschini; Pinheiro, Sergio Veloso Brant; Tavares Junior, Wilson Campos; Vasconcellos, Leonardo de Souza; Alberti, Luiz Ronaldo

    2017-01-01

    Purpose: To evaluate the effects of chronic consumption of green tea on body weight and distribution of visceral fat by Computed tomography in female Wistar rats. Methods: Wistar rats were divided into control group (n = 5), which received water and feed ad libitum, and green tea group (n = 8), in which water has been replaced by green tea. The animals were weighed weekly and Computed Tomography was used at the beginning (1 st week) and end (18 th week) of the experiment for evaluating the distribution of visceral fat. The animals were followed for 18 weeks. Results: There was no significant difference in body weight between the groups. However, there was significant difference in visceral fat area. The green tea group had less visceral fat area at the end of the experiment, 3.67 ± 1.2 cm 2 , while the control group showed an area of 6.25 ± 2.2 cm (p = 0.00). Conclusions: Chronic consumption of green tea leads to decreased visceral adipose tissue area. (author)

  18. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  19. Contrast media on abdominal computed tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.; Oestensen, H.M.

    1984-01-01

    Abdominal computed tomography was performed in 55 patients before and after intravenous injection of 60 ml of a non-ionic (iohexol) or an ionic (metrizoate) contrast medium. The adverse effects were recorded and a series of measurements of attenuation values before and after the contrast medium injection was performed in the aorta and in hepatic and renal parenchyma. Only minor adverse effects were seen with both contrast media, but iohexol was clearly better tolerated than metrizoate. No difference in the enhancement properties was found between the two contrast media. (orig.)

  20. Monte Carlo Calculated Effective Dose to Teenage Girls from Computed Tomography Examinations

    International Nuclear Information System (INIS)

    Caon, M.; Bibbo, G.; Pattison, J.

    2000-01-01

    Effective doses from CT to paediatric patients are not common in the literature. This article reports some effective doses to teenage girls from CT examinations. The voxel computational model ADELAIDE, representative of a 14-year-old girl, was scaled in size by ±5% to represent also 11-12-year-old and 16-year-old girls. The EGS4 Monte Carlo code was used to calculate the effective dose from chest, abdomen and whole torso CT examinations to the three version of ADELAIDE using a 120 kV spectrum. For the whole torso CT examination, in order of increasing model size, the effective doses were 9.0, 8.2 and 7.8 mSv per 100 mA.s. Data are presented that allow the estimation of effective dose from CT examinations of the torso for girls between the ages of 11 and 16. (author)

  1. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    Sawicka, B.

    1992-01-01

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  2. Computed tomography of obstructive jaundice

    International Nuclear Information System (INIS)

    Suh, Jung Hek; Lee, Joong Suk; Chun, Beung He; Suh, Soo Jhi

    1982-01-01

    It is well known that the computed tomography (CT) is very useful in the evaluation of obstructive jaundice. We have studied 55 cases of obstructive jaundice with whole body scanner from Jun.1980 to Jun. 1981. The results were as follows: 1. The sex distribution was 36 males and 19 females, and 40 cases of obstructive jaundice were seen in fifth, sixth, and seventh decades. 2. Causes of obstructive jaundice were 25 cases of pancreas cancer, 8 cases of common duct cancer, 4 cases of gallbladder cancer, 4 cases of ampulla vater cancer, 12 cases of common duct stone, and 2 cases of common duct stricture. 3. Levels of obstruction were 8 cases of hepatic portion, 15 cases of suprapancreatic portion, 28 cases of pancreatic portion, and 4 cases of ampullary portion. 4. In tumorous condition, CT demonstrated metastasis of other organs, 9 cases of the liver, 1 case of the lung, 3 cases of the pancreas, 3 cases of the common bile duct, 1 case of the stomach, and 12 cases of adjacent lymph nodes. 5. Associated diseases were 12 cases of intrahepatic stone, 4 cases of clonorchiasis, 2 cases of pancreas pseudocyst, 1 cases of hydronephrosis, and 1 case of renal cyst

  3. Errors in abdominal computed tomography

    International Nuclear Information System (INIS)

    Stephens, S.; Marting, I.; Dixon, A.K.

    1989-01-01

    Sixty-nine patients are presented in whom a substantial error was made on the initial abdominal computed tomography report. Certain features of these errors have been analysed. In 30 (43.5%) a lesion was simply not recognised (error of observation); in 39 (56.5%) the wrong conclusions were drawn about the nature of normal or abnormal structures (error of interpretation). The 39 errors of interpretation were more complex; in 7 patients an abnormal structure was noted but interpreted as normal, whereas in four a normal structure was thought to represent a lesion. Other interpretive errors included those where the wrong cause for a lesion had been ascribed (24 patients), and those where the abnormality was substantially under-reported (4 patients). Various features of these errors are presented and discussed. Errors were made just as often in relation to small and large lesions. Consultants made as many errors as senior registrar radiologists. It is like that dual reporting is the best method of avoiding such errors and, indeed, this is widely practised in our unit. (Author). 9 refs.; 5 figs.; 1 tab

  4. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  5. X-ray computed tomography

    International Nuclear Information System (INIS)

    Kalender, Willi A

    2006-01-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  6. Computed tomography of epileptic children

    International Nuclear Information System (INIS)

    Kurihara, Mana; Yamashita, Sumimasa; Miyake, Shota; Yamada, Michiko; Iwamoto, Hiroko

    1986-01-01

    The aim of this study was to analyze the changes seen on cranial computed tomography (CT) of epileptic children, especially in the area of the temporal horn. The subjects were 242 epileptic children excluding those with encephalitis, brain tumor, neurocutaneous syndromes, degenerative disease, hydrocephalus etc. The control subjects were 195 children without any neurological disease and symptoms. CT scan were taken with a TCT-60A whole body scanner, and 14 check points were evaluated excluding the temporal horn. 195 epileptic children (N-group) and all control children were normal at 14 check points. Next, the areas of the temporal horns and adjoining hemispheres of the epileptic children (N-group) and control children were examined with Muto-Tablet-Desitizer. The temporal horn ratio ((area of temporal horn/area of ipsilateral hemisphere) x 100) was greater in younger children of the control group, and it was higher in epileptic than in control children. Enlargement of the temporal horn was seen in 1 % of the controls and in 35 % of the 125 epileptic children with normal measurements at 14 points on CT scans (p < 0.01). The frequency of enlargement of temporal horns was not variable among different epileptic types. In the epileptic children with normal CT scans except for enlargement of temporal horns behavioral disturbances were 6 boys and 5 had enlarged temporal horns (bilateral 1 case, left side 1 case, right side 3 cases). (author)

  7. Computed Tomography of Interacerebral Hemorrhage

    International Nuclear Information System (INIS)

    Kim, Seung Hyeon; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Park, Soo Soung

    1983-01-01

    Computed tomography (CT) is the most accurate and reliable method for the diagnosis of intracerebral and intraventricular hemorrhage. The precise anatomic extent of the nematoma, associated cerebral edema, ventricular deformity and displacement, and hydrocephalus are all readily assessed. Aside from head trauma, the principal cause of intracerebral hematoma is hypertensive vascular disease. Although hematomas from various causes may present similar CT appearances frequently the correct etiology may be suggested by consideration of patient's age, clinical history, and the location of the hematoma. The analytical study was performed in 180 cases of intracerebral hemorrhages by CT from October 1981 to January 1983. The results were as follows; 1. The most prevalent age group was 6th decade (37.2%). Male was prevalent to female at the ration of 1.6 to 1. 2. The most common symptom and sign was mental disturbance (48.7%), motor weakness (23%), headache (10.6%), nausea and vomiting (9.8%). 3. The causes of hemorrhage were hypertension (53.9%), head trauma (30.6%), aneurysm (6.1%) and A-V malformation (7.2%). 4. The frequent locations of hemorrhage were basal ganglia and thalamus (40.4%), lobes (35%), ventricles (21.8%). 5. The distribution of hemorrhage was intracerebral hemorrhage (65.6%), intracerebral and intraventricular hemorrhage (30.3%), intraventricular hemorrhage (4.4%).

  8. Recent Developments in Computed Tomography

    International Nuclear Information System (INIS)

    Braunstein, D.; Dafni, E.; Levene, S.; Malamud, G.; Shapiro, O.; Shechter, G.; Zahavi, O.

    1999-01-01

    Computerized Tomography. has become, during the past few years, one of the mostly used apparatus in X-ray diagnosis. Its clinical applications has penetrated to various fields, like operational guidance, cardiac imaging, computer aided surgery etc. The first second-generation CT scanners consisted of a rotate-rotate system detectors array and an X-ray tube. These scanners were capable of acquiring individual single slices, the duration of each being several seconds. The slow scanning rate, and the then poor computers power, limited the application range of these scanners, to relatively stable organs, short body coverage at given resolutions. Further drawbacks of these machines were weak X-ray sources and low efficiency gas detectors. In the late 80's the first helical scanners were introduced by Siemens. Based on a continuous patient couch movement during gantry rotation, much faster scans could be obtained, increasing significantly the volume coverage at a given time. In 1992 the first dual-slice scanners, equipped with high efficiency solid state detectors were introduced by Elscint. The acquisition of data simultaneously from two detector arrays doubled the efficiency of the scan. Faster computers and stronger X-ray sources further improved the performance, allowing for a new range of clinical applications. Yet, the need for even faster machines and bigger volume coverage led to further R and D efforts by the leading CT manufacturers. In order to accomplish the most demanding clinical needs, innovative 2 dimensional 4-rows solid-state detector arrays were developed, together with faster rotating machines and bigger X-ray tubes, all demanding extremely accurate and robust mechanical constructions. Parallel, multi-processor custom computers were made, in order to allow the on-line reconstruction of the growing amounts of raw data. Four-slice helical scanners, rotating at 0.5 sec per cycle are being tested nowadays in several clinics all over the world. This talk

  9. The application of positron emission tomography/computed tomography in radiation treatment planning: effect on gross target volume definition and treatment management.

    Science.gov (United States)

    Iğdem, S; Alço, G; Ercan, T; Unalan, B; Kara, B; Geceer, G; Akman, C; Zengin, F O; Atilla, S; Okkan, S

    2010-04-01

    To analyse the effect of the use of molecular imaging on gross target volume (GTV) definition and treatment management. Fifty patients with various solid tumours who underwent positron emission tomography (PET)/computed tomography (CT) simulation for radiotherapy planning from 2006 to 2008 were enrolled in this study. First, F-18 fluorodeoxyglucose (FDG)-PET and CT scans of the treatment site in the treatment position and then a whole body scan were carried out with a dedicated PET/CT scanner and fused thereafter. FDG-avid primary tumour and lymph nodes were included into the GTV. A multidisciplinary team defined the target volume, and contouring was carried out by a radiation oncologist using visual methods. To compare the PET/CT-based volumes with CT-based volumes, contours were drawn on CT-only data with the help of site-specific radiologists who were blind to the PET/CT results after a median time of 7 months. In general, our PET/CT volumes were larger than our CT-based volumes. This difference was significant in patients with head and neck cancers. Major changes (> or =25%) in GTV delineation were observed in 44% of patients. In 16% of cases, PET/CT detected incidental second primaries and metastatic disease, changing the treatment strategy from curative to palliative. Integrating functional imaging with FDG-PET/CT into the radiotherapy planning process resulted in major changes in a significant proportion of our patients. An interdisciplinary approach between imaging and radiation oncology departments is essential in defining the target volumes. Copyright 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  10. Effects of polytetrafluoroethylene treatment and compression on gas diffusion layer microstructure using high-resolution X-ray computed tomography

    Science.gov (United States)

    Khajeh-Hosseini-Dalasm, Navvab; Sasabe, Takashi; Tokumasu, Takashi; Pasaogullari, Ugur

    2014-11-01

    The microstructure of a TGP-H-120 Toray paper gas diffusion layer (GDL) was investigated using high resolution X-ray computed tomography (CT) technique, with a resolution of 1.8 μm and a field of view (FOV) of ∼1.8 × 1.8 mm. The images obtained from the tomography scans were further post processed, and image thresholding and binarization methodologies are presented. The validity of Otsu's thresholding method was examined. Detailed information on bulk porosity and porosity distribution of the GDL at various Polytetrafluoroethylene (PTFE) treatments and uniform/non-uniform compression pressures was provided. A sample holder was designed to investigate the effects of non-uniform compression pressure, which enabled regulating compression pressure between 0, and 3 MPa at a gas channel/current collector rib configuration. The results show the heterogeneous and anisotropic microstructure of the GDL, non-uniform distribution of PTFE, and significant microstructural change under uniform/non-uniform compression. These findings provide useful inputs for numerical models to include the effects of microstructural changes in the study of transport phenomena within the GDL and to increase the accuracy and predictability of cell performance.

  11. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  12. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  13. Effect of time lapse on the diagnostic accuracy of cone beam computed tomography for detection of vertical root fractures

    Energy Technology Data Exchange (ETDEWEB)

    Eskandarloo, Amir; Shokri, Abbas, E-mail: Dr.a.shokri@gmail.com [Dental Research Center, Department of Oral and Maxillofacial Radiology, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Asl, Amin Mahdavi [Department of Oral and Maxillofacial Radiology, Golestan University of Medical Sciences, Gorgan (Iran, Islamic Republic of); Jalalzadeh, Mohsen [Department of Endodontics, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Tayari, Maryam [Department of Pedodontics, Golestan University of Medical Sciences, Gorgan (Iran, Islamic Republic of); Hosseinipanah, Mohammad [Department of Anatomy, School of Medicine, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Fardmal, Javad [Research Center for Health Sciences and Department of Epidemiology and Biostatistics, School of Public Health, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of)

    2016-01-15

    Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog’s teeth. Forty eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans. (author)

  14. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice

    Directory of Open Access Journals (Sweden)

    Blaine A. Christiansen

    2016-12-01

    Full Text Available Micro-computed tomography (μCT is currently the gold standard for determining trabecular bone microstructure in small animal models. Numerous parameters associated with scanning and evaluation of μCT scans can strongly affect morphologic results obtained from bone samples. However, the effect of these parameters on specific trabecular bone outcomes is not well understood. This study investigated the effect of μCT scanning with nominal voxel sizes between 6–30 μm on trabecular bone outcomes quantified in mouse vertebral body trabecular bone. Additionally, two methods for determining a global segmentation threshold were compared: based on qualitative assessment of 2D images, or based on quantitative assessment of image histograms. It was found that nominal voxel size had a strong effect on several commonly reported trabecular bone parameters, in particular connectivity density, trabecular thickness, and bone tissue mineral density. Additionally, the two segmentation methods provided similar trabecular bone outcomes for scans with small nominal voxel sizes, but considerably different outcomes for scans with larger voxel sizes. The Qualitatively Selected segmentation method more consistently estimated trabecular bone volume fraction (BV/TV and trabecular thickness across different voxel sizes, but the Histogram segmentation method more consistently estimated trabecular number, trabecular separation, and structure model index. Altogether, these results suggest that high-resolution scans be used whenever possible to provide the most accurate estimation of trabecular bone microstructure, and that the limitations of accurately determining trabecular bone outcomes should be considered when selecting scan parameters and making conclusions about inter-group variance or between-group differences in studies of trabecular bone microstructure in small animals. Keywords: Trabecular bone, Microstructure, Micro-computed tomography, Voxel size, Resolution

  15. Effect of time lapse on the diagnostic accuracy of cone beam computed tomography for detection of vertical root fractures

    International Nuclear Information System (INIS)

    Eskandarloo, Amir; Shokri, Abbas; Asl, Amin Mahdavi; Jalalzadeh, Mohsen; Tayari, Maryam; Hosseinipanah, Mohammad; Fardmal, Javad

    2016-01-01

    Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog’s teeth. Forty eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans. (author)

  16. Total variation-based neutron computed tomography

    Science.gov (United States)

    Barnard, Richard C.; Bilheux, Hassina; Toops, Todd; Nafziger, Eric; Finney, Charles; Splitter, Derek; Archibald, Rick

    2018-05-01

    We perform the neutron computed tomography reconstruction problem via an inverse problem formulation with a total variation penalty. In the case of highly under-resolved angular measurements, the total variation penalty suppresses high-frequency artifacts which appear in filtered back projections. In order to efficiently compute solutions for this problem, we implement a variation of the split Bregman algorithm; due to the error-forgetting nature of the algorithm, the computational cost of updating can be significantly reduced via very inexact approximate linear solvers. We present the effectiveness of the algorithm in the significantly low-angular sampling case using synthetic test problems as well as data obtained from a high flux neutron source. The algorithm removes artifacts and can even roughly capture small features when an extremely low number of angles are used.

  17. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  18. Effects on costs of frontline diagnostic evaluation in patients suspected of angina: coronary computed tomography angiography vs. conventional ischaemia testing

    DEFF Research Database (Denmark)

    Nielsen, Lene H; Olsen, Jens; Markenvard, John

    2013-01-01

    group. The mean (SD) total costs per patient at the end of thefollow-up were 14% lower in the CTA group than in the ex-test group, € 1510 (3474) vs. €1777 (3746) (P = 0.03). CONCLUSION: Diagnostic assessment of symptomatic patients with a low-intermediate probability of CAD by CTA incurred lower costs......AIMS: The aim of this study was to investigate in patients with stable angina the effects on costs of frontline diagnostics by exercise-stress testing (ex-test) vs. coronary computed tomography angiography (CTA). METHODS AND RESULTS: In two coronary units at Lillebaelt Hospital, Denmark, 498...... patients were identified in whom either ex-test (n = 247) or CTA (n = 251) were applied as the frontline diagnostic strategy in symptomatic patients with a low-intermediate pre-test probability of coronary artery disease (CAD). During 12 months of follow-up, death, myocardial infarction and costs...

  19. The assessment of chemotherapy and radiation therapy effect in malignant lymphomas with computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Dobrovolskiene, L.; Griniute, R.

    2003-01-01

    Aim of this study was to estimate the diagnostic possibilities of computed tomography (CT) and magnetic resonance imaging (MRI) in the assessment of treatment effect in malignant lymphomas. In the period of 1998 to 2002, 196 patients with histologically proven malignant lymphoma were examined in the Department of Tomography of Kaunas University of Medicine Hospital. The data were processed with SPSS 10.1, including application of standardized t-test and classification of Fisher's statistics. In this group the density of lymphomatous masses prior and post treatment has no difference on CT images, thus the differentiation of active tissue and relapse is not possible. On MR images the difference of signal intensity of the active component (not treated) and fibrous remnant is significant. MRI is a radiological method which provides information about activity of lymphomatous tissue and is able to delineate the active component (recidive or partial remission) and inactive remnant (total remission) of the tumor mass and thus facilitating the diagnosis of possible relapse of malignant lymphomas for hematology, chemotherapy and radiotherapy specialists. (author)

  20. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Moraes, Everton; Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase; Gazzoni, Fernando; Lopes, Luis Felipe Dias

    2007-01-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  1. Orbital computed tomography for exophthalmos

    International Nuclear Information System (INIS)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo

    1987-01-01

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos

  2. Computed tomography of cerebrovascular accidents

    International Nuclear Information System (INIS)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin

    1989-01-01

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography

  3. Computed tomography of cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1989-10-15

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography.

  4. Orbital computed tomography for exophthalmos

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo [College of Medicine, Pusan National University, Busan (Korea, Republic of)

    1987-06-15

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos.

  5. Image quality in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Gerke, Oke; Thygesen, Jesper

    2018-01-01

    Background Computed tomography (CT) technology is rapidly evolving and software solution developed to optimize image quality and/or lower radiation dose. Purpose To investigate the influence of adaptive statistical iterative reconstruction (ASIR) at different radiation doses in coronary CT...

  6. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  7. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  8. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  9. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  10. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  11. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  12. Calculation of normalised organ and effective doses to adult reference computational phantoms from contemporary computed tomography scanners

    International Nuclear Information System (INIS)

    Jansen, Jan T.M.; Shrimpton, Paul C.

    2010-01-01

    The general-purpose Monte Carlo radiation transport code MCNPX has been used to simulate photon transport and energy deposition in anthropomorphic phantoms due to the x-ray exposure from the Philips iCT 256 and Siemens Definition CT scanners, together with the previously studied General Electric 9800. The MCNPX code was compiled with the Intel FORTRAN compiler and run on a Linux PC cluster. A patch has been successfully applied to reduce computing times by about 4%. The International Commission on Radiological Protection (ICRP) has recently published the Adult Male (AM) and Adult Female (AF) reference computational voxel phantoms as successors to the Medical Internal Radiation Dose (MIRD) stylised hermaphrodite mathematical phantoms that form the basis for the widely-used ImPACT CT dosimetry tool. Comparisons of normalised organ and effective doses calculated for a range of scanner operating conditions have demonstrated significant differences in results (in excess of 30%) between the voxel and mathematical phantoms as a result of variations in anatomy. These analyses illustrate the significant influence of choice of phantom on normalised organ doses and the need for standardisation to facilitate comparisons of dose. Further such dose simulations are needed in order to update the ImPACT CT Patient Dosimetry spreadsheet for contemporary CT practice. (author)

  13. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. A PC program for estimating organ dose and effective dose values in computed tomography

    International Nuclear Information System (INIS)

    Kalender, W.A.; Schmidt, B.; Schmidt, M.; Zankl, M.

    1999-01-01

    Dose values in CT are specified by the manufacturers for all CT systems and operating conditions in phantoms. It is not trivial, however, to derive dose values in patients from this information. Therefore, we have developed a PC-based program which calculates organ dose and effective dose values for arbitrary scan parameters and anatomical ranges. Values for primary radiation are derived from measurements or manufacturer specifications; values for scattered radiation are derived from Monte Carlo calculations tabulated for standard anthropomorphic phantoms. Based on these values, organ doses can be computed by the program for arbitrary scan protocols in conventional and in spiral CT. Effective dose values are also provided, both with ICRP 26 and ICRP 60 tissue-weighting coefficients. Results for several standard CT protocols are presented in tabular form in this paper. In addition, potential for dose reduction is demonstrated, for example, in spiral CT and in quantitative CT. Providing realistic patient dose estimates for arbitrary CT protocols is relevant both for the physician and the patient, and it is particularly useful for educational and training purposes. The program, called WinDose, is now in use at the Erlangen University hospitals (Germany) as an information tool for radiologists and patients. Further extensions are planned. (orig.)

  15. Cost-effectiveness modeling of colorectal cancer: Computed tomography colonography vs colonoscopy or fecal occult blood tests

    International Nuclear Information System (INIS)

    Lucidarme, Olivier; Cadi, Mehdi; Berger, Genevieve; Taieb, Julien; Poynard, Thierry; Grenier, Philippe; Beresniak, Ariel

    2012-01-01

    Objectives: To assess the cost-effectiveness of three colorectal-cancer (CRC) screening strategies in France: fecal-occult-blood tests (FOBT), computed-tomography-colonography (CTC) and optical-colonoscopy (OC). Methods: Ten-year simulation modeling was used to assess a virtual asymptomatic, average-risk population 50–74 years old. Negative OC was repeated 10 years later, and OC positive for advanced or non-advanced adenoma 3 or 5 years later, respectively. FOBT was repeated biennially. Negative CTC was repeated 5 years later. Positive CTC and FOBT led to triennial OC. Total cost and CRC rate after 10 years for each screening strategy and 0–100% adherence rates with 10% increments were computed. Transition probabilities were programmed using distribution ranges to account for uncertainty parameters. Direct medical costs were estimated using the French national health insurance prices. Probabilistic sensitivity analyses used 5000 Monte Carlo simulations generating model outcomes and standard deviations. Results: For a given adherence rate, CTC screening was always the most effective but not the most cost-effective. FOBT was the least effective but most cost-effective strategy. OC was of intermediate efficacy and the least cost-effective strategy. Without screening, treatment of 123 CRC per 10,000 individuals would cost €3,444,000. For 60% adherence, the respective costs of preventing and treating, respectively 49 and 74 FOBT-detected, 73 and 50 CTC-detected and 63 and 60 OC-detected CRC would be €2,810,000, €6,450,000 and €9,340,000. Conclusion: Simulation modeling helped to identify what would be the most effective (CTC) and cost-effective screening (FOBT) strategy in the setting of mass CRC screening in France.

  16. Computed tomography of intraventricular hemorrhage

    International Nuclear Information System (INIS)

    Cho, Bum Shin; Shin, Kyoung Hee; Hahm, Chang Kok

    1982-01-01

    Computed tomography (CT) is a new non-invasive diagnostic imaging method, which has ability to differentiate C.S.F., hematoma, and even edematous brain from normal brain tissue. Prior to the introduction of the CT, the diagnosis of the intraventricular hemorrhage in living patients was difficult and was confirmed by surgery of autopsy. Intracranial hemorrhages are visible on the CT with density higher than brain tissue in acute phase. CT is an accurate method for detecting of intraventricular hemorrhage including detection of nature, location, amount, and associated changes. CT is also useful as a guidance and in the evaluation of fate of the hematomas by easily performable follow up studies. The causes of the intraventricular hemorrhages are hypertension, rupture of aneurysm, arteriovenous malformation, head trauma, brain tumor, and others. This study included evaluation of CT of 69 patients who show the high density in cerebral ventricular system during the period of 31 months from Feb. 1979 to Aug. 1981 in the Department of Radiology, College of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 69 patient was broad ranging from 1 month to 80 years. 28% of patients were in the 6th decade. The mate to female ratio was 2 : 1. 2. The consciousness of patients at CT study: Those were conscious in 11 cases, stuporous in 41 cases and unconscious in 17 cases. 3. The causes of intraventricular hemorrhages were hypertension in 28 cases, head trauma in 12 cases, aneurysm in 4 cases, tumor in 2 cases and others in 23 cases. 4. 9 cases showed intraventricular hematomas only, other 60 cases showed associated intracranial hematomas: Those were intracerebral hematomas in 53 cases including 30 cases of basal ganglial and thalamic hematomas, subarachnoid hemorrhage in 17 cases, epidural hematomas in 3 cases, and subdural hematomas in 2 cases. 5. All cases of the intraventricular hematomas except one sowed hematoma in the lateral

  17. Computed tomography in subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Lee, Seung Ro; Chang, Kee Hyun; Choi, Byung Ihn; Han, Man Chung; Sim, Bo Sung

    1981-01-01

    Computed Tomography has become increasingly important diagnostic method as the initial examination in the diagnosis of subarachnoid hemorrhage with direct detection of extravasated blood in basal cistern and cortical sulci. Furthermore, CT provides better and exact visualization of the presence, localization, extent and degree of intracerebral, intraventricular and subdural hemorrhage, infarction, hydrocephalus and rebleeding which may be associated with subarachnoid hemorrhage, and also could detect the causative lesions with contrast enhancement in many cases. The purpose of the paper is to describe the CT findings of subarachnoid hemorrhage due to various causes and to evaluate the diagnostic accuracy of CT in subarachnoid hemorrhage. Authors analysed a total of 153 cases with subarachnoid hemorrhage confirmed by lumbar puncture at Seoul National University Hospital from March 1979 to April 1981, with special emphasis on CT findings. All of the cases took CT scan and 125 cases of them angiography. The results are as follows: 1. Most prevalent age group was 4th to 6th decades (78%). The ratio of male to female was 1.1: 1. 2. Of 125 cases with angiography, aneurysm was a major cause (68%). Others were arterio-venous malformation (9.6%), Moya-moya disease (4%) and unknown (18.4%). 3. Of all 153 cases with CT scan, hemorrhage was demonstrated in 98 cases (64.1%); SAH in 72 cases (47.1%), ICH in 65 cases (42.5%), IVH in 34 cases (22.2%) and SDH in 1 case (0.7%). SAH combined with ICH was a major group (34.7%) in SAH. Detection rate of SAH was 68.3% within the first 7 days and 5.8% after 7 dyas. 4. In aneurysms, SAH was detected in 60 of 85 cases (70.6%); 88.1% within the first 7 dyas and 5.6% after 7 dyas. Anterior communicating artery was the most common site of the aneurysms (40%), in which detection rate of SAH was 100% within the first 7 days. SAH was combined with ICH in 38.3%. 5. On CT, SAH of unilateral Sylvian fissure was pathognomonic for ruptured MCA

  18. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  19. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  20. Speeding up image reconstruction in computed tomography

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    Computed tomography (CT) is a technique for imaging cross-sections of an object using X-ray measurements taken from different angles. In last decades a significant progress has happened there: today advanced algorithms allow fast image reconstruction and obtaining high-quality images even with missing or dirty data, modern detectors provide high resolution without increasing radiation dose, and high-performance multi-core computing devices are there to help us solving such tasks even faster. I will start with CT basics, then briefly present existing classes of reconstruction algorithms and their differences. After that I will proceed to employing distinctive architectural features of modern multi-core devices (CPUs and GPUs) and popular program interfaces (OpenMP, MPI, CUDA, OpenCL) for developing effective parallel realizations of image reconstruction algorithms. Decreasing full reconstruction time from long hours up to minutes or even seconds has a revolutionary impact in diagnostic medicine and industria...

  1. Solitary pulmonary nodule evaluation in regions endemic for infectious diseases: Do regional variations impact the effectiveness of fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Purandare, N C; Pramesh, C S; Agarwal, J P; Agrawal, A; Shah, S; Prabhash, K; Karimundackal, G; Jiwnani, S; Tandon, S; Rangarajan, V

    2017-01-01

    Fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) has become a preferred imaging modality for the evaluation of solitary pulmonary nodule (SPN), particularly in the developed world. Since FDG can concentrate in infective/inflammatory lesions, the diagnostic utility of FDG-PET can be questioned, particularly in regions endemic for infectious decisions. To evaluate the accuracy of FDG-PET/CT in evaluation of SPNs in a population endemic for infectious disease and to assess if regional variations have an impact on its effectiveness. All patients who underwent an FDG/PET-CT with a clinico-radiological diagnosis of SPN categorized as indeterminate were included. Based on a maximum standardized uptake values (SUVmax) cut-off of 2.5, lesions were classified as benign (2.5) and compared with gold standard histopathology. The diagnostic accuracy of PET-CT to detect malignancy was calculated. On the basis of final histopathology, lesions were grouped as (a) malignant nodules (b) infective/granulomatous nodules with a specific diagnosis and (c) nonspecific inflammatory nodules. The SUVmaxbetween these groups was compared using nonparametric statistical tests. A total of 191 patients (129 males, 62 females) with a median age of 64 years (range: 36-83) were included. Totally, 144 nodules (75.3%) were malignant and 47 were benign (24.7%). Adenocarcinoma (n = 84) was the most common malignancy. Tuberculosis (n = 16) and nonspecific infections (n = 24) were the two most common benign pathologies. There was a significant overlap in the metabolic uptake of malignant (median SUVmax-11.2, range: 3.3-34.6) and tuberculous nodules (median SUVmax-10.3, range: 2.7-22.5) with no statistically difference between their SUVmaxvalues (P = 0.43). The false-positive rate was 65.2% and the false-negative rate was 5.5%. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FDG-PET/CT for detecting malignancy were 94

  2. Effectiveness of Adaptive Statistical Iterative Reconstruction for 64-Slice Dual-Energy Computed Tomography Pulmonary Angiography in Patients With a Reduced Iodine Load: Comparison With Standard Computed Tomography Pulmonary Angiography.

    Science.gov (United States)

    Lee, Ji Won; Lee, Geewon; Lee, Nam Kyung; Moon, Jin Il; Ju, Yun Hye; Suh, Young Ju; Jeong, Yeon Joo

    2016-01-01

    The aim of the study was to assess the effectiveness of the adaptive statistical iterative reconstruction (ASIR) for dual-energy computed tomography pulmonary angiography (DE-CTPA) with a reduced iodine load. One hundred forty patients referred for chest CT were randomly divided into a DE-CTPA group with a reduced iodine load or a standard CTPA group. Quantitative and qualitative image qualities of virtual monochromatic spectral (VMS) images with filtered back projection (VMS-FBP) and those with 50% ASIR (VMS-ASIR) in the DE-CTPA group were compared. Image qualities of VMS-ASIR images in the DE-CTPA group and ASIR images in the standard CTPA group were also compared. All quantitative and qualitative indices, except attenuation value of pulmonary artery in the VMS-ASIR subgroup, were superior to those in the VMS-FBP subgroup (all P ASIR images were superior to those of ASIR images in the standard CTPA group (P ASIR images of the DE-CTPA group than in ASIR images of the standard CTPA group (P = 0.001). The ASIR technique tends to improve the image quality of VMS imaging. Dual-energy computed tomography pulmonary angiography with ASIR can reduce contrast medium volume and produce images of comparable quality with those of standard CTPA.

  3. Assessment of the effective dose in supine, prone, and oblique positions in the maxillofacial region using a novel combined extremity and maxillofacial cone beam computed tomography scanner

    NARCIS (Netherlands)

    Koivisto, J.; Wolff, J.; Järnstedt, J.; Dastidar, P.; Kortesniemi, M.

    2014-01-01

    Objective The objectives of this study were to assess the organ and effective doses (International Commission on Radiological Protection [ICRP] 103 standard) resulting from supine, prone, and oblique phantom positions in the maxillofacial region using a novel cone beam computed tomography (CBCT)

  4. The effect of blood pressure on non-invasive fractional flow reserve derived from coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Akira [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Coenen, Adriaan; Lubbers, Marisa M.; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Departmenet of Cardiology, Rotterdam (Netherlands); Kido, Teruhito; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Kido, Tomoyuki [Matsuyama Saiseikai Hospital, Department of Radiology, Matsuyama, Ehime (Japan); Yamashita, Natsumi [Clinical Research Center, National Hospital Organization Shikoku Cancer Center, Division of Clinical Biostatistics, Section of Cancer Prevention and Epidemiology, Matsuyama, Ehime (Japan); Watanabe, Kouki [Matsuyama Saiseikai Hospital, Department of Cardiology, Matsuyama, Ehime (Japan); Krestin, Gabriel P. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2017-04-15

    The aim of this study is to assess the effect of blood pressure (BP) on coronary computed tomography angiography (CTA) derived computational fractional flow reserve (CTA-FFR). Twenty-one patients who underwent coronary CTA and invasive FFR were retrospectively identified. Ischemia was defined as invasive FFR ≤0.80. Using a work-in-progress computational fluid dynamics algorithm, CTA-FFR was computed with BP measured before CTA, and simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg respectively. Correlation between CTA-FFR and invasive FFR was assessed using Pearson test. The repeated measuring test was used for multiple comparisons of CTA-FFR values by simulated BP inputs. Twenty-nine vessels (14 with invasive FFR ≤0.80) were assessed. The average CTA-FFR for measured BP (134 ± 20/73 ± 12 mmHg) was 0.77 ± 0.12. Correlation between CTA-FFR by measured BP and invasive FFR was good (r = 0.735, P < 0.001). For simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg, the CTA-FFR increased: 0.69 ± 0.13, 0.73 ± 0.12, 0.75 ± 0.12, 0.77 ± 0.11, 0.79 ± 0.11, and 0.81 ± 0.10 respectively (P < 0.05). Measurement of the BP just before CTA is preferred for accurate CTA-FFR simulation. BP variations in the common range slightly affect CTA-FFR. However, inaccurate BP assumptions differing from the patient-specific BP could cause misinterpretation of borderline significant lesions. (orig.)

  5. The effect of blood pressure on non-invasive fractional flow reserve derived from coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Kurata, Akira; Coenen, Adriaan; Lubbers, Marisa M.; Nieman, Koen; Kido, Teruhito; Mochizuki, Teruhito; Kido, Tomoyuki; Yamashita, Natsumi; Watanabe, Kouki; Krestin, Gabriel P.

    2017-01-01

    The aim of this study is to assess the effect of blood pressure (BP) on coronary computed tomography angiography (CTA) derived computational fractional flow reserve (CTA-FFR). Twenty-one patients who underwent coronary CTA and invasive FFR were retrospectively identified. Ischemia was defined as invasive FFR ≤0.80. Using a work-in-progress computational fluid dynamics algorithm, CTA-FFR was computed with BP measured before CTA, and simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg respectively. Correlation between CTA-FFR and invasive FFR was assessed using Pearson test. The repeated measuring test was used for multiple comparisons of CTA-FFR values by simulated BP inputs. Twenty-nine vessels (14 with invasive FFR ≤0.80) were assessed. The average CTA-FFR for measured BP (134 ± 20/73 ± 12 mmHg) was 0.77 ± 0.12. Correlation between CTA-FFR by measured BP and invasive FFR was good (r = 0.735, P < 0.001). For simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg, the CTA-FFR increased: 0.69 ± 0.13, 0.73 ± 0.12, 0.75 ± 0.12, 0.77 ± 0.11, 0.79 ± 0.11, and 0.81 ± 0.10 respectively (P < 0.05). Measurement of the BP just before CTA is preferred for accurate CTA-FFR simulation. BP variations in the common range slightly affect CTA-FFR. However, inaccurate BP assumptions differing from the patient-specific BP could cause misinterpretation of borderline significant lesions. (orig.)

  6. Computed tomography of the menisci

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.; Rupp, N.; Paar, O.; Rodammer, G.

    1988-01-01

    Thirty patients were examined with CT of the menisci. All findings were confirmed by arthroscopy. One false positive diagnosis of a torn meniscus was made, caused by partial volume effect. In seven patients with irregular degenerative changes of the menisci, the abnormality could be clearly demonstrated. One meniscus ganglion was shown. Seven meniscus lesions, which were not shown by arthrography or arthroscopy, were clearly demonstrated by CT. The computer tomographic demonstration of menisci can replace knee arthrography as the examination of choice and should be performed before carrying out arthroscopy. (orig.) [de

  7. Comparison of computed tomography dose reporting software

    International Nuclear Information System (INIS)

    Abdullah, A.; Sun, Z.; Pongnapang, N.; Ng, K. H.

    2008-01-01

    Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover (Germany)), ImPACT CT Patients Dosimetry Calculator (version 0.99x, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck (Germany)), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen (Germany)) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen (Germany)) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly. (authors)

  8. Computed tomography of cartilaginous tumours

    International Nuclear Information System (INIS)

    Marincek, B.; Triller, J.; Robotti, G.; Gumppenberg, S. von

    1984-01-01

    The compound tomography (CT) morphology of cartilaginous tumors and the utility of CT in their diagnostic work-up is presented on the basis of 19 cases. CT provided unique informations regarding definition of tumor extent and tumor relationship to adjacent structures particularly in the axial skeleton. CT has diminished the indications for angiography in cartilaginous tumors. (orig.) [de

  9. SU-G-IeP3-04: Effective Dose Measurements in Fast Kvp Switch Dual Energy Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Raudabaugh, J; Moore, B [Duke Medical Physics, Duke Radiation Dosimetry Laboratory (United States); Nguyen, G; Yoshizumi, T [Duke Radiology, Duke Radiation Dosimetry Laboratory (United States); Lowry, C; Nelson, R [Duke Radiology (United States)

    2016-06-15

    Purpose: The objective of this study was two-fold: (a) to test a new approach to approximating organ dose by using the effective energy of the combined 80kV/140kV beam in dual-energy (DE) computed tomography (CT), and (b) to derive the effective dose (ED) in the abdomen-pelvis protocol in DECT. Methods: A commercial dual energy CT scanner was employed using a fast-kV switch abdomen/pelvis protocol alternating between 80 kV and 140 kV. MOSFET detectors were used for organ dose measurements. First, an experimental validation of the dose equivalency between MOSFET and ion chamber (as a gold standard) was performed using a CTDI phantom. Second, the ED of DECT scans was measured using MOSFET detectors and an anthropomorphic phantom. For ED calculations, an abdomen/pelvis scan was used using ICRP 103 tissue weighting factors; ED was also computed using the AAPM Dose Length Product (DLP) method and compared to the MOSFET value. Results: The effective energy was determined as 42.9 kV under the combined beam from half-value layer (HVL) measurement. ED for the dual-energy scan was calculated as 16.49 ± 0.04 mSv by the MOSFET method and 14.62 mSv by the DLP method. Conclusion: Tissue dose in the center of the CTDI body phantom was 1.71 ± 0.01 cGy (ion chamber) and 1.71 ± 0.06 (MOSFET) respectively; this validated the use of effective energy method for organ dose estimation. ED from the abdomen-pelvis scan was calculated as 16.49 ± 0.04 mSv by MOSFET and 14.62 mSv by the DLP method; this suggests that the DLP method provides a reasonable approximation to the ED.

  10. The effect of clinical bias on the interpretation of myelography and spinal computed tomography

    International Nuclear Information System (INIS)

    Eldevik, O.P.; Dugstad, G.; Orrison, W.W.; Haughton, V.M.

    1982-01-01

    Spinal computed tomograms and myelograms of 107 patients with sciatica or low back pain were interpreted with and without knowledge of clinical history. A significant number of interpretations was changed by knowledge of the clinical history. More studies were interpreted correctly without the clinical history than with it. Knowledge of the clinical history increased the number of false-positive and decreased the number of false-negative diagnoses. This study suggest a tendency of observers to interpret questionable myelographic or computed tomograhic findings as positive when they correlate with clinical findings

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which rotates around the patient. The computer that processes the imaging information and monitor are located in ... follows a spiral path. A special computer program processes this series of pictures, or slices of the ...

  13. Parotid gland sparing effect by computed tomography-based modified lower field margin in whole brain radiotherapy

    International Nuclear Information System (INIS)

    Cho, Oyeon; Chun, Mi Son; Oh, Young Taek; Kim, Mi Hwa; Park, Hae Jin; Nam, Sang Soo; Heo, Jae Sung; Noh, O Kyu; Park, Sung Ho

    2013-01-01

    Parotid gland can be considered as a risk organ in whole brain radiotherapy (WBRT). The purpose of this study is to evaluate the parotid gland sparing effect of computed tomography (CT)-based WBRT compared to 2-dimensional plan with conventional field margin. From January 2008 to April 2011, 53 patients underwent WBRT using CT-based simulation. Bilateral two-field arrangement was used and the prescribed dose was 30 Gy in 10 fractions. We compared the parotid dose between 2 radiotherapy plans using different lower field margins: conventional field to the lower level of the atlas (CF) and modified field fitted to the brain tissue (MF). Averages of mean parotid dose of the 2 protocols with CF and MF were 17.4 Gy and 8.7 Gy, respectively (p 98% of prescribed dose were 99.7% for CF and 99.5% for MF. Compared to WBRT with CF, CT-based lower field margin modification is a simple and effective technique for sparing the parotid gland, while providing similar dose coverage of the whole brain.

  14. Effect of Metal Artifacts on Detection of Vertical Root Fractures Using Two Cone Beam Computed Tomography Systems.

    Science.gov (United States)

    Safi, Yaser; Aghdasi, Mohammad Mehdi; Ezoddini-Ardakani, Fatemeh; Beiraghi, Samira; Vasegh, Zahra

    2015-01-01

    Vertical root fracture (VRF) is common in endodontically treated teeth. Conventional and digital radiographies have limitations for detection of VRFs. Cone-beam computed tomography (CBCT) offers greater detection accuracy of VRFs in comparison with conventional radiography. This study compared the effects of metal artifacts on detection of VRFs by using two CBCT systems. Eighty extracted premolars were selected and sectioned at the level of the cemento enamel junction (CEJ). After preparation, root canals were filled with gutta-percha. Subsequently, two thirds of the root fillings were removed for post space preparation and a custom-made post was cemented into each canal. The teeth were randomly divided into two groups (n=40). In the test group, root fracture was created with Instron universal testing machine. The control teeth remained intact. CBCT scans of all teeth were obtained with either New Tom VGI or Soredex Scanora 3D. Three observers analyzed the images for detection of VRF. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for VRF detection and percentage of probable cases were calculated for each imaging system and compared using non-parametric tests considering the non-normal distribution of data. The inter-observer reproducibility was calculated using the weighted kappa coefficient. There were no statistically significant differences in sensitivity, specificity, PPV and NPV between the two CBCT systems. The effect of metal artifacts on VRF detection was not significantly different between the two CBCT systems.

  15. The value of 201Tl myocardial scintigraphy and of computed tomography for predicting the effectiveness of coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Krosse, B.; Duck, H.J.; Neumann, G.; Huppert, P.; Schulz, H.G.; Lindenau, K.F.

    1986-01-01

    50 male patients with stenosing coronary artery sclerosis and an indication for coronary artery bypass surgery were subjected to pre- and postsurgical 201 Tl scintigraphy and postsurgical computed tomography. Control by angiography was carried out in six cases. Scintigraphy revealed an improved myocardial perfusion in 30 patients, whereas it was unchanged in 15 and deteriorated in 5 patients. Angiography exhibited two cases of graft occlusion, one case of bad run off, and two cases of progressing arteriosclerosis under intact graft. Computed tomography showed that 83 bypasses of the 50 patients were occluded in 6 cases, which was confirmed by angiography in 3 cases. The investigation demonstrates the high value of the two non-invasive methods for the control of bypass patency. (author)

  16. The feasibility study on 3-dimensional fluorescent x-ray computed tomography using the pinhole effect for biomedical applications.

    Science.gov (United States)

    Sunaguchi, Naoki; Yuasa, Tetsuya; Hyodo, Kazuyuki; Zeniya, Tsutomu

    2013-01-01

    We propose a 3-dimensional fluorescent x-ray computed tomography (CT) pinhole collimator, aimed at providing molecular imaging with quantifiable measures and sub-millimeter spatial resolution. In this study, we demonstrate the feasibility of this concept and investigate imaging properties such as spatial resolution, contrast resolution and quantifiable measures, by imaging physical phantoms using a preliminary imaging system developed with monochromatic synchrotron x rays constructed at the BLNE-7A experimental line at KEK, Japan.

  17. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Schom, C.; Engelke, W.; Kopka, L.; Fischer, U.; Grabbe, E.

    1996-01-01

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.) [de

  18. Effects of progressive strength training on muscle mass in type 2 diabetes mellitus patients determined by computed tomography

    International Nuclear Information System (INIS)

    Cauza, E.; Strehblow, C.; Hanusch-Enserer, U.; Fasching, P.; Metz-Schimmerl, S.; Strasser, B.; Kostner, K.; Dunstan, D.; Haber, P.

    2009-01-01

    To examine the effect of a 4-month progressive strength training program on muscle and fat mass assessed by computed tomography (CT) in type 2 diabetes mellitus (T2DM) patients, and to assess the relationships of changes in muscle cross-section area (CSA) with glycaemic control. Twenty adults (mean age ± SE: 56.4 ± 0.9 a) with T2DM participated in a supervised strength training program for 4 months 3 days/week. Muscle and fat areas of the quadriceps muscle were estimated by CT volumetry before and immediately after the training. Glycaemic (HbA1c) and anthropometric (BMI, skinfolds) measurements were assessed at 0 and 4 months, respectively. After strength training, muscle strength increased significantly in all measured muscle groups. Quadriceps size (CSA of the muscle) was increased by 2.4 % (from 7.99 ± 0.3 cm 3 to 8.18 ± 0.3 cm 3 , p = 0.003) for the right extremity, 3.9 % (from 8.1 ± 0.4 cm 3 to 8.41 ± 0.5 cm 3 , p = 0.04) for the left side. Fat tissue CSA reduced from 0.66 ± 0.1 cm 3 to 0.56 ± 0.12 cm 3 for the right leg (15.3 % reduction) and from 0.58 ± 0.12 cm 3 to 0.37 ± 0.13 cm 3 for the left leg (35.8 % reduction), resulting in a mean fat CSA reduction of 24.8 %. Fat mass assessed by skin folds was significantly reduced and lean body mass was significantly increased. The change in muscle CSA was not correlated with the changes in HbA1c or muscle strength. Strength training significantly improves both muscle mass and the muscle to fat ratio in T2DM. However, changes in muscle observed with computed tomography were not related to changes observed in HbA1c with training. (author) [de

  19. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  20. Computed tomography of sacro-iliac joints

    International Nuclear Information System (INIS)

    Miquel, A.; Laredo, J.D.

    1995-01-01

    Actual technologies to explore sacro-iliac joints are conventional radiography, computed tomography , scintigraphy and nuclear magnetic resonance imaging. Standards films are sufficient, except in beginning sacro-iliac septic inflammations where the computed tomography is superior. Two problems are generally posed for the radiologist, to differentiate a septic arthritis from a rheumatic pathology An other problem in diagnosis is to make the difference between a degenerative arthropathy (which does not need a further investigation) and an infectious rheumatic pathology where more exploration is necessary. 28 refs., 3 tabs., 13 figs

  1. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2014-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... examined the content, data quality, and research potential of the WDHR-CCTR. METHODS: We retrieved 2008-2012 data to examine the 1) content; 2) completeness of procedure registration using the Danish National Patient Registry as reference; 3) completeness of variable registration comparing observed vs...

  2. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  3. Computed tomography in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki

    1990-01-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.)

  4. Scintigraphic evaluation of coronary thrombolysis with urokinase using /sup 201/Tl-emission computed tomography. Effect on infarct size

    Energy Technology Data Exchange (ETDEWEB)

    Kambara, Hirofumi; Tamaki, Shunichi; Kadota, Kazunori; Nohara, Takashi; Suzuki, Yukisono; Tamaki, Nagara; Torizuka, Kanji; Kawai, Chuichi [Kyoto Univ. (Japan). Faculty of Medicine

    1984-09-01

    Twenty-seven patients with first acute myocardial infarction were evaluated by serial determination of creatine kinase (CK) and thallium-201 myocardial emission computed tomography (ECT) performed four weeks after infarction. Total release of CK-MB and peak CK-MB had a linear correlation with infarct volume calculated by ECT, but a different relationship was found in between patients with successful coronary thrombolysis and those without. The former group of patients had an earlier peak of CK-MB and larger release of the cardiac enzyme comparative to infarct volume than the latter group. In 28 cases with proximal occlusion of the anterior descending coronary artery ECT-infarct volume was smaller with ealier recanalization within 10 hours after onset of infarction and, therefore, the time delay of recanalization may be allowed up to 10 hours. In conclusion, early coronary recanalization is an effective method to limit infarct size and time limit may be up to 10 hours after onset of infarction. But enzymatic calculation of infarct size should be modified when early coronary recanalization was expected.

  5. An Effective Approach of Teeth Segmentation within the 3D Cone Beam Computed Tomography Image Based on Deformable Surface Model

    Directory of Open Access Journals (Sweden)

    Xutang Zhang

    2016-01-01

    Full Text Available In order to extract the pixels of teeth from 3D Cone Beam Computed Tomography (CBCT image, in this paper, a novel 3D segmentation approach based on deformable surface mode is developed for 3D tooth model reconstruction. Different forces are formulated to handle the segmentation problem by using different strategies. First, the proposed method estimates the deformation force of vertex model by simulating the deformation process of a bubble under the action of internal pressure and external force field. To handle the blurry boundary, a “braking force” is proposed deriving from the 3D gradient information calculated by transforming the Sobel operator into three-dimension representation. In addition, a “border reinforcement” strategy is developed for handling the cases with complicate structures. Moreover, the proposed method combines affine cell image decomposition (ACID grid reparameterization technique to handle the unstable changes of topological structure and deformability during the deformation process. The proposed method was performed on 510 CBCT images. To validate the performance, the results were compared with those of two other well-studied methods. Experimental results show that the proposed approach had a good performance in handling the cases with complicate structures and blurry boundaries well, is effective to converge, and can successfully achieve the reconstruction task of various types of teeth in oral cavity.

  6. [Effective Techniques to Reduce Radiation Exposure to Medical Staff during Assist of X-ray Computed Tomography Examination].

    Science.gov (United States)

    Miyajima, Ryuichi; Fujibuchi, Toshioh; Miyachi, Yusuke; Tateishi, Satoshi; Uno, Yoshinori; Amakawa, Kazutoshi; Ohura, Hiroki; Orita, Shinichi

    2018-01-01

    Medical staffs like radiological technologists, doctors, and nurses are at an increased risk of exposure to radiation while assisting the patient in a position or monitor contrast medium injection during computed tomography (CT). However, methods to protect medical staff from radiation exposure and protocols for using radiological protection equipment have not been standardized and differ among hospitals. In this study, the distribution of scattered X-rays in a CT room was measured by placing electronic personal dosimeters in locations where medical staff stands beside the CT scanner gantry while assisting the patient and the exposure dose was measured. Moreover, we evaluated non-uniform exposure and revealed effective techniques to reduce the exposure dose to medical staff during CT. The dose of the scattered X-rays was the lowest at the gantry and at the examination table during both head and abdominal CT. The dose was the highest at the trunk of the upper body of the operator corresponding to a height of 130 cm during head CT and at the head corresponding to a height of 150 cm during abdominal CT. The maximum dose to the crystalline lens was approximately 600 μSv during head CT. We found that the use of volumetric CT scanning and X-ray protective goggles, and face direction toward the gantry reduced the exposure dose, particularly to the crystalline lens, for which lower equivalent dose during CT scan has been recently recommended in the International Commission on Radiological Protection Publication 118.

  7. Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Capunay, C.; Carrascosa, P.; Vallejos, J.; Deviggiano, A.; Pollono, P.M.; Garcia, M.J.

    2011-01-01

    Objective. To determine the imaging quality and effective radiation dose (ERD) of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCTCA) compared to retrospective ECG-gating (RMDCT-CA). Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n=45) and without (n=45) tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver variability was k=0.92 (95 % CI: 0.87-0.96). The ERD (mean ± SD) using PMDCT-CA was 2.88 ± 0.37 mSv compared to 10.50 ± 1.15 mSv (p [es

  8. Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography

    International Nuclear Information System (INIS)

    Jung, Mi Young; Kweon, Dae Cheol; Kwon, Soo Il

    2009-01-01

    The purpose of our study was to determine the eye radiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lens shielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eye with the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lens without qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  9. Technological Evolution on Computed Tomography and Radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho [Servico de Radiologia, Hospital de Curry Cabral, Rua da Beneficencia, 8, 1069-166 Lisboa (Portugal)

    2006-05-15

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  10. Technological Evolution on Computed Tomography and Radioprotection

    International Nuclear Information System (INIS)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho

    2006-01-01

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  11. Computed tomography of radioactive objects and materials

    International Nuclear Information System (INIS)

    Sawicka, B.D.; Murphy, R.V.; Tosello, G.; Reynolds, P.W.; Romaniszyn, T.

    1990-01-01

    Computed tomography (CT) has been performed on a number of radioactive objects and materials. Several unique technical problems are associated with CT of radioactive specimens. These include general safety considerations, techniques to reduce background-radiation effects on CT images and selection criteria for the CT source to permit object penetration and to reveal accurate values of material density. In the present paper, three groups of experiments will be described, for objects with low, medium and high levels of radioactivity. CT studies on radioactive specimens will be presented. They include the following: (1) examination of individual ceramic reactor-fuel (uranium dioxide) pellets, (2) examination of fuel samples from the Three Mile Island reactor, (3) examination of a CANDU (CANada Deuterium Uranium: registered trademark) nuclear-fuel bundle which underwent a simulated loss-of-coolant accident resulting in high-temperature damage and (4) examination of a PWR nuclear-reactor fuel assembly. (orig.)

  12. MicroComputed Tomography: Methodology and Applications

    International Nuclear Information System (INIS)

    Stock, Stuart R.

    2009-01-01

    Due to the availability of commercial laboratory systems and the emergence of user facilities at synchrotron radiation sources, studies of microcomputed tomography or microCT have increased exponentially. MicroComputed Technology provides a complete introduction to the technology, describing how to use it effectively and understand its results. The first part of the book focuses on methodology, covering experimental methods, data analysis, and visualization approaches. The second part addresses various microCT applications, including porous solids, microstructural evolution, soft tissue studies, multimode studies, and indirect analyses. The author presents a sufficient amount of fundamental material so that those new to the field can develop a relative understanding of how to design their own microCT studies. One of the first full-length references dedicated to microCT, this book provides an accessible introduction to field, supplemented with application examples and color images.

  13. Effectiveness of rosiglitazone on bleomycin-induced lung fibrosis: Assessed by micro-computed tomography and pathologic scores

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Bok, Se Mi; Han, Young Min; Chung, Myung Ja; Yoon, Kwon-Ha; Kim, So Ri; Lee, Yong Chul

    2012-01-01

    Peroxisome proliferator-activated receptor-γ (PPARγ) agonists exhibit potent anti-fibrotic effects in the lung and other tissues. Recently, micro-computed tomography (CT) has been a useful tool for the investigation of lung diseases in small animals and is now increasingly applied to visualize and quantify the pulmonary structures. However, there is little information on the assessment for therapeutic effects of PPARγ agonists on the pulmonary fibrosis in mice using micro-CT. This study was aimed to determine the capability of micro-CT in examining the effects of rosiglitazone on pulmonary fibrosis. We used a murine model of bleomycin-induced lung fibrosis to evaluate the feasibility of micro-CT in evaluating the therapeutic potential of rosiglitazone on pulmonary fibrosis, comparing with pathologic scores. On micro-CT findings, ground glass opacity (80%) and consolidation (20%) were observed predominantly at 3 weeks after the instillation of bleomycin, and the radiologic features became more complex at 6 weeks. In bleomycin-instilled mice treated with rosiglitazone, the majority (80%) showed normal lung features on micro-CT. Radiological-pathologic correlation analyses revealed that ground glass opacity and consolidation were correlated closely with acute inflammation, while reticular opacity was well correlated with histological honeycomb appearance. These results demonstrate that rosiglitazone displays a protective effect on pulmonary fibrosis in mice and that the visualization of bleomycin-induced pulmonary fibrosis using micro-CT is satisfactory to assess the effects of rosiglitazone. It implies that micro-CT can be applied to evaluate therapeutic efficacies of a variety of candidate drugs for lung diseases.

  14. Effectiveness of rosiglitazone on bleomycin-induced lung fibrosis: Assessed by micro-computed tomography and pathologic scores

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Gong Yong; Bok, Se Mi; Han, Young Min [Department of Radiology, Chonbuk National University Medical School, Jeonju (Korea, Republic of); Chung, Myung Ja [Department of Pathology, Chonbuk National University Medical School, Jeonju (Korea, Republic of); Yoon, Kwon-Ha [Department of Radiology, Iksan Hospital, Iksan (Korea, Republic of); Kim, So Ri [Department of Internal Medicine and Research Center for Pulmonary Disorders, Chonbuk National University Medical School, Jeonju (Korea, Republic of); Lee, Yong Chul, E-mail: leeyc@jbnu.ac.kr [Department of Internal Medicine and Research Center for Pulmonary Disorders, Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2012-08-15

    Peroxisome proliferator-activated receptor-{gamma} (PPAR{gamma}) agonists exhibit potent anti-fibrotic effects in the lung and other tissues. Recently, micro-computed tomography (CT) has been a useful tool for the investigation of lung diseases in small animals and is now increasingly applied to visualize and quantify the pulmonary structures. However, there is little information on the assessment for therapeutic effects of PPAR{gamma} agonists on the pulmonary fibrosis in mice using micro-CT. This study was aimed to determine the capability of micro-CT in examining the effects of rosiglitazone on pulmonary fibrosis. We used a murine model of bleomycin-induced lung fibrosis to evaluate the feasibility of micro-CT in evaluating the therapeutic potential of rosiglitazone on pulmonary fibrosis, comparing with pathologic scores. On micro-CT findings, ground glass opacity (80%) and consolidation (20%) were observed predominantly at 3 weeks after the instillation of bleomycin, and the radiologic features became more complex at 6 weeks. In bleomycin-instilled mice treated with rosiglitazone, the majority (80%) showed normal lung features on micro-CT. Radiological-pathologic correlation analyses revealed that ground glass opacity and consolidation were correlated closely with acute inflammation, while reticular opacity was well correlated with histological honeycomb appearance. These results demonstrate that rosiglitazone displays a protective effect on pulmonary fibrosis in mice and that the visualization of bleomycin-induced pulmonary fibrosis using micro-CT is satisfactory to assess the effects of rosiglitazone. It implies that micro-CT can be applied to evaluate therapeutic efficacies of a variety of candidate drugs for lung diseases.

  15. Gender-specific calculation of the effective dose: The example of thoracic computer tomography

    International Nuclear Information System (INIS)

    Boetticher, H. von; Lachmund, J.; Hoffmann, W.

    2003-01-01

    Systematic gender-specific differences in anatomy and physiology are mostly neglected in standard methodologies for the determination of effective doses. This paper presents and discusses three different concepts for the derivation of gender-specific effective doses. Based on the most convincing approach - especially through the influence of tissue weighting factors for the breast - the effective dose for a serial CT scan of the chest is higher for women (+11%) and lower (-11%) for men in comparison to the 'gender-neutral' average value. These differences amount to ±30% for coronary serial CT applications. (orig.) [de

  16. Effect of furosemide administration before F-18 fluorodeoxyglucose positron emission tomography/computed tomography on urine radioactivity and detection of uterine cervical cancer.

    Science.gov (United States)

    d'Amico, Andrea; Gorczewska, Izabela; Gorczewski, Kamil; Turska-d'Amico, Maria; Di Pietro, Marco

    2014-01-01

    In evaluating uterine cervical cancer with ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT), there may be overlap between the FDG activity at tumor sites and nonspecific radioactivity in the urine. We evaluated the efficacy of furosemide premedication with routine hydration to obtain better contrast and less overlap between cervical cancer and the urinary bladder. We retrospectively evaluated 166 patients who had primary or relapsed cervical cancer and underwent FDG PET/CT scanning with (133 patients) or without (33 patients) furosemide premedication (10 mg intravenous, slowly injected 30 min before the scan). We calculated bladder and tumor maximum and median standardized uptake value (SUVmax and SUVmed), and overlap between tumor and urinary activity was detected visually. Overlap between urinary and tumor radioactivity was observed in 8 of 133 scans (6%) in patients who receive furosemide and in 3 of 33 scans (9%) in patients who did not receive furosemide. The SUVmax and SUVmed for the bladder were significantly lower in patients who were pretreated with furosemide (SUVmax, 6.3; SUVmed, 4.6) than patients who were not pretreated with furosemide (SUVmax, 8.8 [P ≤ 0.008]; SUVmed, 6.5 [P ≤ 0.002]). The tumor SUVmax and SUVmed were similar between the patient groups. Furosemide premedication before FDG PET/CT scanning may enable improved evaluation of activity and extension of cervical cancer.

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... so that the x-ray beam follows a spiral path. A special computer program processes this series ... Sometimes ultrasound is substituted for CT as a method of imaging in these procedures in children. A ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ... diabetes, kidney disease or thyroid problems. Any of these conditions may influence the decision on whether contrast ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  2. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  3. Trends in examination frequency and collective effective doses from computed tomography (CT) procedures in Sudan

    International Nuclear Information System (INIS)

    Yousif, S. B. I.

    2011-01-01

    This study was carried out to estimate the examination frequency and collective dose to population from CT procedures in Sudan. To calculate the annual collective dose from CT examinations a survey was done at 10 hospitals providing data of examinations frequency per day. The data of effective dose have been obtained from pervious study on effective dose per CT examination in Sudan. Then the annual examination frequency and annual collective effective dose had been calculated and discussed providing that the annual collective effective dose from CT examinations is (1482 man.Sv). The highest percentage examination frequency was for head examination (40%). The highest percentage contribution to the total collective dose from CT examinations was for abdomen examinations (32%). The calculated annual examination frequency and annual collective effective dose had been compared with the results of literature and international studies to evaluate the estimated values. The calculated annual collective dose from CT examinations is much lower comparing with the results presented in the literature. The study offers an insight on the examination frequency and the percentage of the risk from different standard radiographic examination within the country. (Author)

  4. Cone-beam computed tomography in children with cochlear implants: The effect of electrode array position on ECAP.

    Science.gov (United States)

    Lathuillière, Marine; Merklen, Fanny; Piron, Jean-Pierre; Sicard, Marielle; Villemus, Françoise; Menjot de Champfleur, Nicolas; Venail, Frédéric; Uziel, Alain; Mondain, Michel

    2017-01-01

    To assess the feasibility of using cone-beam computed tomography (CBCT) in young children with cochlear implants (CIs) and study the effect of intracochlear position on electrophysiological and behavioral measurements. A total of 40 children with either unilateral or bilateral cochlear implants were prospectively included in the study. Electrode placement and insertion angles were studied in 55 Cochlear ® implants (16 straight arrays and 39 perimodiolar arrays), using either CBCT or X-ray imaging. CBCT or X-ray imaging were scheduled when the children were leaving the recovery room. We recorded intraoperative and postoperative neural response telemetry threshold (T-NRT) values, intraoperative and postoperative electrode impedance values, as well as behavioral T (threshold) and C (comfort) levels on electrodes 1, 5, 10, 15 and 20. CBCT imaging was feasible without any sedation in 24 children (60%). Accidental scala vestibuli insertion was observed in 3 out of 24 implants as assessed by CBCT. The mean insertion angle was 339.7°±35.8°. The use of a perimodiolar array led to higher angles of insertion, lower postoperative T-NRT, as well as decreased behavioral T and C levels. We found no significant effect of either electrode array position or angle of insertion on electrophysiological data. CBCT appears to be a reliable tool for anatomical assessment of young children with CIs. Intracochlear position had no significant effect on the electrically evoked compound action potential (ECAP) threshold. Our CBCT protocol must be improved to increase the rate of successful investigations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Cost-effectiveness of computed tomography colonography in colorectal cancer screening: a systematic review.

    Science.gov (United States)

    Hanly, Paul; Skally, Mairead; Fenlon, Helen; Sharp, Linda

    2012-10-01

    The European Code Against Cancer recommends individuals aged ≥ 50 should participate in colorectal cancer screening. CT-colonography (CTC) is one of several screening tests available. We systematically reviewed evidence on, and identified key factors influencing, cost-effectiveness of CTC screening. PubMed, Medline, and the Cochrane library were searched for cost-effectiveness or cost-utility analyses of CTC-based screening, published in English, January 1999 to July 2010. Data was abstracted on setting, model type and horizon, screening scenario(s), comparator(s), participants, uptake, CTC performance and cost, effectiveness, ICERs, and whether extra-colonic findings and medical complications were considered. Sixteen studies were identified from the United States (n = 11), Canada (n = 2), and France, Italy, and the United Kingdom (1 each). Markov state-transition (n = 14) or microsimulation (n = 2) models were used. Eleven considered direct medical costs only; five included indirect costs. Fourteen compared CTC with no screening; fourteen compared CTC with colonoscopy-based screening; fewer compared CTC with sigmoidoscopy (8) or fecal tests (4). Outcomes assessed were life-years gained/saved (13), QALYs (2), or both (1). Three considered extra-colonic findings; seven considered complications. CTC appeared cost-effective versus no screening and, in general, flexible sigmoidoscopy and fecal occult blood testing. Results were mixed comparing CTC to colonoscopy. Parameters most influencing cost-effectiveness included: CTC costs, screening uptake, threshold for polyp referral, and extra-colonic findings. Evidence on cost-effectiveness of CTC screening is heterogeneous, due largely to between-study differences in comparators and parameter values. Future studies should: compare CTC with currently favored tests, especially fecal immunochemical tests; consider extra-colonic findings; and conduct comprehensive sensitivity analyses.

  6. The exponential edge-gradient effect in x-ray computed tomography

    International Nuclear Information System (INIS)

    Joseph, P.M.

    1981-01-01

    The exponential edge-gradient effect must arise in any X-ray transmission CT scanner whenever long sharp edges of high contrast are encountered. The effect is non-linear and is due to the interaction of the exponential law of X-ray attenuation and the finite width of the scanning beam in the x-y plane. The error induced in the projection values is proved to be always negative. While the most common effect is lucent streaks emerging from single straight edges, it is demonstrated that dense streaks from pairs of edges are possible. It is shown that an exact correction of the error is possible only under very special (and rather unrealistic) circumstances in which an infinite number of samples per beam width are available and all thin rays making up the beam can be considered parallel. As a practical matter, nevertheless, increased sample density is highly desirable in making good approximate corrections; this is demonstrated with simulated scans. Two classes of approximate correction algorithms are described and their effectiveness evaluated on simulated CT phantom scans. One such algorithm is also shown to work well with a real scan of a physical phantom on a machine that provides approximately four samples per beam width. (author)

  7. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  8. Computed Tomography Study Of Complicated Bacterial Meningitis ...

    African Journals Online (AJOL)

    To monitor the structural intracranial complications of bacterial meningitis using computed tomography (CT) scan. Retrospective study of medical and radiological records of patients who underwent CT scan over a 4 year period. AUniversityTeachingHospital in a developing country. Thirty three patients with clinically and ...

  9. Computed tomography - old ideas and new technology

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik; Boas, F.E. [Stanford University, School of Medicine, Department of Radiology, Stanford, CA (United States)

    2011-03-15

    Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

  10. Computed tomography in the evaluation of trauma

    International Nuclear Information System (INIS)

    Federle, M.P.; Brant-Zawadzki, M.

    1982-01-01

    This book is intended to be the current standard for computed tomography in the evaluation of trauma. It summarizes two years of experience at San Francisco General Hospital. The book is organized into seven chapters, covering head, maxillofacial, laryngeal, spinal, chest, abdominal, acetabular, and pelvic trauma. Extremity trauma is not discussed

  11. Computed tomography (CT) and diastematomyelia's diagnosis

    International Nuclear Information System (INIS)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S.; Barros, A.P. de

    1982-01-01

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized. (Author) [pt

  12. Computed tomography evaluation of petrous bone fractures ...

    African Journals Online (AJOL)

    Background: Petrous bone trauma is the sequel of blunt head injury and can have life threatening complications resulting in immediate mortality. Early detection and good knowledge of the Computed Tomography (CT) findings ensure prompt treatment of both fractures and complications. Objective: To document the ...

  13. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  14. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...

  15. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  16. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  17. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  18. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...

  19. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...

  20. Investigation of measuring strategies in computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2011-01-01

    Computed tomography has entered the industrial world in 1980’s as a technique for non-destructive testing and has nowadays become a revolutionary tool for dimensional metrology, suitable for actual/nominal comparison and verification of geometrical and dimensional tolerances. This paper evaluates...

  1. Computed tomography in severe protein energy malnutrition.

    OpenAIRE

    Househam, K C; de Villiers, J F

    1987-01-01

    Computed tomography of the brain was performed on eight children aged 1 to 4 years with severe protein energy malnutrition. Clinical features typical of kwashiorkor were present in all the children studied. Severe cerebral atrophy or brain shrinkage according to standard radiological criteria was present in every case. The findings of this study suggest considerable cerebral insult associated with severe protein energy malnutrition.

  2. Computed tomography of the iliopsoas muscle

    International Nuclear Information System (INIS)

    Nino-Murcia, M.; Wechsler, R.J.; Brennan, R.E.

    1983-01-01

    Computed tomography (CT) is an ideal method for the imaging of the psoas muscle. The authors present 13 cases of patients with psoas abnormalities diagnosed by CT. The CT features of the different pathologic entities and comparison of CT with other imaging modalities are discussed. (orig.)

  3. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal

  4. Estimating the effective radiation dose imparted to patients by intraoperative cone-beam computed tomography in thoracolumbar spinal surgery.

    Science.gov (United States)

    Lange, Jeffrey; Karellas, Andrew; Street, John; Eck, Jason C; Lapinsky, Anthony; Connolly, Patrick J; Dipaola, Christian P

    2013-03-01

    Observational. To estimate the radiation dose imparted to patients during typical thoracolumbar spinal surgical scenarios. Minimally invasive techniques continue to become more common in spine surgery. Computer-assisted navigation systems coupled with intraoperative cone-beam computed tomography (CT) represent one such method used to aid in instrumented spinal procedures. Some studies indicate that cone-beam CT technology delivers a relatively low dose of radiation to patients compared with other x-ray-based imaging modalities. The goal of this study was to estimate the radiation exposure to the patient imparted during typical posterior thoracolumbar instrumented spinal procedures, using intraoperative cone-beam CT and to place these values in the context of standard CT doses. Cone-beam CT scans were obtained using Medtronic O-arm (Medtronic, Minneapolis, MN). Thermoluminescence dosimeters were placed in a linear array on a foam-plastic thoracolumbar spine model centered above the radiation source for O-arm presets of lumbar scans for small or large patients. In-air dosimeter measurements were converted to skin surface measurements, using published conversion factors. Dose-length product was calculated from these values. Effective dose was estimated using published effective dose to dose-length product conversion factors. Calculated dosages for many full-length procedures using the small-patient setting fell within the range of published effective doses of abdominal CT scans (1-31 mSv). Calculated dosages for many full-length procedures using the large-patient setting fell within the range of published effective doses of abdominal CT scans when the number of scans did not exceed 3. We have demonstrated that single cone-beam CT scans and most full-length posterior instrumented spinal procedures using O-arm in standard mode would likely impart a radiation dose within the range of those imparted by a single standard CT scan of the abdomen. Radiation dose increases

  5. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  6. Computed tomography of tuberculous meningitis

    International Nuclear Information System (INIS)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto

    1982-01-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis. (author)

  7. Misty mesentery: computed tomography findings

    International Nuclear Information System (INIS)

    Ahualli, Jorge; Mendez Uriburu, Luis; Ravera, Maria L.; Cikman, Pablo

    2008-01-01

    An alteration in the density of the mesenteric adipose tissue is often the principal clue of underlying mesenteric and bowel disease. The term 'Misty Mesentery' describes the computed tomographic appearance of mesenteric fat infiltrated by inflammatory cells, fluid (edema, lymph, and/or blood), tumor, and fibrosis. (author) [es

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... detectors rotate around the patient. At the same time, the examination table is moving through the scanner, so that the x-ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the body, to ...

  10. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    was not used. Autopsies were performed according to the Danish government's official guidelines. PMCT and autopsy findings were interpreted independent of each other. Diagnoses, including the cause of death and histology findings, were registered in a computer database (SPSS) together with information about...

  11. Computed tomography in Alexander's disease

    Energy Technology Data Exchange (ETDEWEB)

    Holland, I M; Kendall, B E

    1980-10-01

    Two cases of biopsy-proven Alexander's disease are described with computed tomographic changes which, in our experience and on survey of the literature, have not occurred in any other condition. Such changes in a child with a progressive condition consistent with Alexander's disease, strongly support the diagnosis.

  12. Computed tomography of limy bile

    International Nuclear Information System (INIS)

    Yamamoto, Shinichiro; Kimoto, Masatoshi; Gunge, Nobuharu; Sano, Kaizo; Yamashita, Sachiko; Hirano, Yutaka

    1983-01-01

    The computed tomographic appearance of three cases of limy bile was reported. The CT findings consist of uniform high density within gallbladder, niveau formation between limy bile and noncalcified bile. Sagittal reconstruction of CT images was especially useful in the differentiation of limy bile and gallstones. (author)

  13. Multislice spiral computed tomography to determine the effects of a recruitment maneuver in experimental lung injury

    Energy Technology Data Exchange (ETDEWEB)

    Henzler, Dietrich; Rossaint, Rolf [University Hospital, RWTH Aachen, Anesthesiology Department, Aachen (Germany); Mahnken, Andreas H.; Wildberger, Joachim E.; Guenther, Rolf W. [University Hospital of the RWTH Aachen, Clinic of Diagnostic Radiology, Aachen (Germany); Kuhlen, Ralf [University Hospital of the RWTH Aachen, Operative Intensive Care Department, Aachen (Germany)

    2006-06-15

    Although recruitment of atelectatic lung is a common aim in acute respiratory distress syndrome (ARDS), the effects of a recruitment maneuver have not been assessed quantitatively. By multislice spiral CT (MSCT), we analyzed the changes in lung volumes calculated from the changes in the CT values of hyperinflated (V{sub HYP}), normally (V{sub NORM}), poorly (V{sub POOR}) and nonaerated (V{sub NON}) lung in eight mechanically ventilated pigs with saline lavage-induced acute lung injury before and after a recruitment maneuver. This was compared to single slice analysis near the diaphragm. The increase in aerated lung was mainly for V{sub POOR} and the less in V{sub NORM}. Total lung volume and intrathoracic gas increased. No differences were found for tidal volumes measured by spirometry or determined by CT. The inspiratory-expiratory volume differences were not different after the recruitment maneuver in V{sub NON} (from 62{+-}18 ml to 43{+-}26 ml, P=0.114), and in V{sub NORM} (from 216{+-}51 ml to 251{+-}37 ml, P=0.102). Single slice analysis significantly underestimated the increase in normally and poorly aerated lung. Quantitative analysis of lung volumes by whole lung MSCT revealed the increase of poorly aerated lung as the main mechanism of a standard recruitment maneuver. MSCT can provide additional information as compared to single slice CT. (orig.)

  14. Evaluation of the effects of an arm artifact reduction filter in computed tomography

    International Nuclear Information System (INIS)

    Nozaki, Fumie; Ohno, Hajime; Hirako, Tetsuya

    2002-01-01

    While performing CT during arterial portography (CTAP) or CT arteriography (CTA), we have instructed patients to in order to reduce streak artifacts. However the repetitive raising and lowering their arms has made it difficult to keep a clean zone and as well as to maintain the position of a target organ. An arm artifact reduction (AAR) filter developed by GE Yokokawa Medical System has been reported to be useful for reducing streak artifacts in CTAP and CTA. The purpose of this study was to estimate the effectiveness of the AAR filter in terms of artifact reduction ratio, CT value, standard deviation and spatial resolution. The use of an AAR filter reduced streak artifacts on images by 15-22% compared with those on images obtained by without the use of the filter and limited deterioration of spatial resolution to within 1%. Moreover, CT value in examination using AAR filter showed no significant change compared with that in non-filter's examination. It is concluded that the use of an AAR filter reduces the burden for the patient and increase the accuracy and flexibility of CT examination while minimizing the reduction in the image quality in CTAP and CTA. (author)

  15. Multislice spiral computed tomography to determine the effects of a recruitment maneuver in experimental lung injury

    International Nuclear Information System (INIS)

    Henzler, Dietrich; Rossaint, Rolf; Mahnken, Andreas H.; Wildberger, Joachim E.; Guenther, Rolf W.; Kuhlen, Ralf

    2006-01-01

    Although recruitment of atelectatic lung is a common aim in acute respiratory distress syndrome (ARDS), the effects of a recruitment maneuver have not been assessed quantitatively. By multislice spiral CT (MSCT), we analyzed the changes in lung volumes calculated from the changes in the CT values of hyperinflated (V HYP ), normally (V NORM ), poorly (V POOR ) and nonaerated (V NON ) lung in eight mechanically ventilated pigs with saline lavage-induced acute lung injury before and after a recruitment maneuver. This was compared to single slice analysis near the diaphragm. The increase in aerated lung was mainly for V POOR and the less in V NORM . Total lung volume and intrathoracic gas increased. No differences were found for tidal volumes measured by spirometry or determined by CT. The inspiratory-expiratory volume differences were not different after the recruitment maneuver in V NON (from 62±18 ml to 43±26 ml, P=0.114), and in V NORM (from 216±51 ml to 251±37 ml, P=0.102). Single slice analysis significantly underestimated the increase in normally and poorly aerated lung. Quantitative analysis of lung volumes by whole lung MSCT revealed the increase of poorly aerated lung as the main mechanism of a standard recruitment maneuver. MSCT can provide additional information as compared to single slice CT. (orig.)

  16. The effect of irradiation on the subcutaneous fatty layer and the perirectal tissue by computed tomography

    International Nuclear Information System (INIS)

    Komatsu, Takashi

    1987-01-01

    Although it has been suggested that the subcutaneous fatty layer is affected by irradiation, the available reports have not been able to find out yet. While, it is reported that the intrapelvic fat increases in volume after whole pelvic irradiation. This paper report a study about the effect of irradiation on subcutaneous fatty layer and intrapelvic fat. The subjects studied were 20 cases treated by whole pelvic irradiation. The x-ray CT film was used to measure the subcutaneous fatty layer and the intrapelvic fat. Three slices, the lower end of sacro-iliac joint, upper end of the femoral head and upper rim of the pubic symphysis, were chosen as the cross section level, and the thickness of subcutaneous fatty layer on 6 points of the body and the presacral space (PS) were measured. Irradiation group was followed by measuring the thickness of fatty layer; before irradiation, 1 month, 3 or 4 months, 6 or 7 months and 12 months after irradiation. At the three of four points, which are included within the irradiation area, the thickness of subcutaneous fatty layer tended to increase after irradiation, though it showed increase or decrease at each period. This tendency was prominent at the lower than the upper slice of the pelvis. The other points, which are out of the irradiation field, showed no significant change and some of them even showed the tendency of decrease. Fatty layer of the presacral space tended to increase following irradiation, but there was no correlation with the irradiation dose. It is considered that the injury of subcutaneous tissue by irradiation results in the disturbance of blood flow and then it accelerates deposition of fat to the irradiated area. (author)

  17. Computed tomography shielding methods: a literature review.

    Science.gov (United States)

    Curtis, Jessica Ryann

    2010-01-01

    To investigate available shielding methods in an effort to further awareness and understanding of existing preventive measures related to patient exposure in computed tomography (CT) scanning. Searches were conducted to locate literature discussing the effectiveness of commercially available shields. Literature containing information regarding breast, gonad, eye and thyroid shielding was identified. Because of rapidly advancing technology, the selection of articles was limited to those published within the past 5 years. The selected studies were examined using the following topics as guidelines: the effectiveness of the shield (percentage of dose reduction), the shield's effect on image quality, arguments for or against its use (including practicality) and overall recommendation for its use in clinical practice. Only a limited number of studies have been performed on the use of shields for the eyes, thyroid and gonads, but the evidence shows an overall benefit to their use. Breast shielding has been the most studied shielding method, with consistent agreement throughout the literature on its effectiveness at reducing radiation dose. The effect of shielding on image quality was not remarkable in a majority of studies. Although it is noted that more studies need to be conducted regarding the impact on image quality, the currently published literature stresses the importance of shielding in reducing dose. Commercially available shields for the breast, thyroid, eyes and gonads should be implemented in clinical practice. Further research is needed to ascertain the prevalence of shielding in the clinical setting.

  18. Thermoluminescent dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Lara C, A.; Rivera M, T.; Osorio V, M.; Hernandez O, O.

    2016-10-01

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  19. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  20. Cerebral candidiasis. Computed tomography appearance

    International Nuclear Information System (INIS)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-01-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.)

  1. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  2. Microfocus computed tomography in medicine

    Science.gov (United States)

    Obodovskiy, A. V.

    2018-02-01

    Recent advances in the field of high-frequency power schemes for X-ray devices allow the creation of high-resolution instruments. At the department of electronic devices and Equipment of the St. Petersburg State Electrotechnical University, a model of a microfocus computer tomograph was developed. Used equipment allows to receive projection data with an increase up to 100 times. A distinctive feature of the device is the possibility of implementing various schemes for obtaining projection data.

  3. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  4. Computed tomography of thymic abnormalities

    International Nuclear Information System (INIS)

    Schnyder, P.; Candardjis, G.

    1987-01-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis. (orig.)

  5. Orbital computed tomography: technical aspects

    International Nuclear Information System (INIS)

    Beck, T.J.; Rosenbaum, A.E.; Miller, N.R.

    1982-01-01

    Computed tomographic scanning has revolutionized the diagnosis and management of orbital disease. The best use of this methodology requires knowledge of the principles and appropriate attention to scanning protocols. Computed tomographic scanning of the orbit is a demanding technique requiring thin sections through planes precisely positioned from the topographical anatomy. Ideally, orbital CT should include both transverse axial and coronal sections: The pathological condition and its plane of growth will influence the selection of the optimal plane or section. Coronal sections may be obtained either directly or indirectly by computer reconstruction from contiguous transverse images. Sagittal or oblique sections or both also are useful and may be obtained directly or indirectly. Difficulty in patient positioning may preclude direct sagittal imaging, however. The use of intravenous contrast enhancement is not necessary as a routine technique unless a mass is identified or suspected. Where surgical resection or biopsy of a space-occupying lesion is contemplated, contrast enhancement can be valuable in assessing relative vascularity and aiding diagnostic specificity. It should be continually emphasized that CT is a powerful technology which, in orbital diagnosis, produces the highest yield when clinician and radiologist collaborate in the radiodiagnostic workup. The clinical information supplied by the referring ophthalmologist is used by the radiologist both in the selection of the appropriate techniques for investigation and in striving to achieve the most specific conclusion

  6. Proton computed tomography images with algebraic reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bruzzi, M. [Physics and Astronomy Department, University of Florence, Florence (Italy); Civinini, C.; Scaringella, M. [INFN - Florence Division, Florence (Italy); Bonanno, D. [INFN - Catania Division, Catania (Italy); Brianzi, M. [INFN - Florence Division, Florence (Italy); Carpinelli, M. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Cirrone, G.A.P.; Cuttone, G. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Presti, D. Lo [INFN - Catania Division, Catania (Italy); Physics and Astronomy Department, University of Catania, Catania (Italy); Maccioni, G. [INFN – Cagliari Division, Cagliari (Italy); Pallotta, S. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Randazzo, N. [INFN - Catania Division, Catania (Italy); Romano, F. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Sipala, V. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Talamonti, C. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Vanzi, E. [Fisica Sanitaria, Azienda Ospedaliero-Universitaria Senese, Siena (Italy)

    2017-02-11

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to ~1% and spatial resolutions <1 mm, achieved within processing times of ~15′ for a 512×512 pixels image prove that this technique will be beneficial if used instead of X-CT in hadron-therapy.

  7. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  8. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    International Nuclear Information System (INIS)

    Macedo, Clarissa Aguiar de; Baena, Marcos Eduardo da Silva; Uezumi, Kiyomi Kato; Castro, Claudio Campi de; Lucarelli, Claudio Luiz; Cerri, Giovanni Guido

    2008-01-01

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  9. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  10. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  11. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  12. Micro-computed tomography pore-scale study of flow in porous media: Effect of voxel resolution

    Science.gov (United States)

    Shah, S. M.; Gray, F.; Crawshaw, J. P.; Boek, E. S.

    2016-09-01

    A fundamental understanding of flow in porous media at the pore-scale is necessary to be able to upscale average displacement processes from core to reservoir scale. The study of fluid flow in porous media at the pore-scale consists of two key procedures: Imaging - reconstruction of three-dimensional (3D) pore space images; and modelling such as with single and two-phase flow simulations with Lattice-Boltzmann (LB) or Pore-Network (PN) Modelling. Here we analyse pore-scale results to predict petrophysical properties such as porosity, single-phase permeability and multi-phase properties at different length scales. The fundamental issue is to understand the image resolution dependency of transport properties, in order to up-scale the flow physics from pore to core scale. In this work, we use a high resolution micro-computed tomography (micro-CT) scanner to image and reconstruct three dimensional pore-scale images of five sandstones (Bentheimer, Berea, Clashach, Doddington and Stainton) and five complex carbonates (Ketton, Estaillades, Middle Eastern sample 3, Middle Eastern sample 5 and Indiana Limestone 1) at four different voxel resolutions (4.4 μm, 6.2 μm, 8.3 μm and 10.2 μm), scanning the same physical field of view. Implementing three phase segmentation (macro-pore phase, intermediate phase and grain phase) on pore-scale images helps to understand the importance of connected macro-porosity in the fluid flow for the samples studied. We then compute the petrophysical properties for all the samples using PN and LB simulations in order to study the influence of voxel resolution on petrophysical properties. We then introduce a numerical coarsening scheme which is used to coarsen a high voxel resolution image (4.4 μm) to lower resolutions (6.2 μm, 8.3 μm and 10.2 μm) and study the impact of coarsening data on macroscopic and multi-phase properties. Numerical coarsening of high resolution data is found to be superior to using a lower resolution scan because it

  13. Effect of intravenous contrast agent volume on colorectal cancer vascular parameters as measured by perfusion computed tomography

    International Nuclear Information System (INIS)

    Goh, V.; Bartram, C.; Halligan, S.

    2009-01-01

    Aim: To determine the effect of two different contrast agent volumes on quantitative and semi-quantitative vascular parameters as measured by perfusion computed tomography (CT) in colorectal cancer. Materials and methods: Following ethical approval and informed consent, eight prospectively recruited patients with proven colorectal adenocarcinoma underwent two separate perfusion CT studies on the same day after (a) 100 ml and (b) 50 ml of a 340 mg/ml iodinated contrast medium, respectively. Quantitative (blood volume, blood flow, permeability surface area product) and semi-quantitative (peak enhancement, time to peak enhancement) tumour vascular parameters were determined using commercial software based on distributed parameter analysis and compared using t-testing. Results: Tumour blood volume, blood flow, and permeability surface area product were not substantially different following the injection of 100 ml and 50 ml contrast medium: 6.12 versus 6.23 ml/100 g tissue; 73.4 versus 71.3 ml/min/100 g tissue; 15.6 versus 15.3 ml/min/100 g tissue for 100 and 50 ml, respectively; p > 0.05. Tumour peak enhancement and time to peak were significantly greater following the injection of 100 ml versus 50 ml contrast medium: 41.2 versus 28.5 HU; 16.1 versus 11.8 s for 100 ml and 50 ml, respectively; p = 0.002; p = 0.0003. Conclusion: Quantitative parameters do not appear to change substantially with a higher contrast agent volume suggesting a combined diagnostic staging-perfusion CT study following a single injection is feasible for colorectal cancer

  14. Effect of variable scanning protocolson the pre-implant site evaluation of the mandible in reformatted computed tomography

    International Nuclear Information System (INIS)

    Kim, Kee Deog; Park, Chang Seo

    1999-01-01

    To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. On image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal and in horizontal measurement, there was no statistically significant difference among conventional and helical scans with pitches of 1.0, 1.5 and 2.0. In vertical measurement, there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of pre-dental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  15. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  16. Computed tomography and radioprotection: Knowing and acting

    International Nuclear Information System (INIS)

    Ducou Le Pointe, H.

    2013-01-01

    Exposure of the population to ionizing radiation for medical purposes is increasing throughout the world. In the United States of America, this exposure (3 mSv) has reached, even exceeded, exposure from natural sources. In France, the report of the French Institute for Radiological Protection and Nuclear Safety (IRSN) on exposure of the French population to ionizing radiation in 2007, based on the 74.6 million medical diagnostic procedures, estimates the mean individual effective dose to be 1.3 mSv. This value is much lower than the value in the United States but has progressed in 5 years by 62.5%. Computed tomography accounts for 10.1% of the procedures and 58% of the collective effective dose. This is why computed tomography is receiving very special attention from all those involved in radioprotection. It must be remembered, nevertheless, that we are well within the low dose range (effective dose less than 100 mSv), and indeed, in the large majority of CT examinations exposure values are lower than 15 mSv. The biological effects of low doses are still a matter of debate. First of all, it has not been possible to demonstrate the risk of cancer due to this level of exposure, neither on the survivors of the atomic bombs in Japan nor on workers in the nuclear industry in the United Kingdom. The year 2012 marked a change; for the first time, epidemiology took over from statistical studies. Despite the low risk demonstrated, reserves concerning methodology, and waiting for further European epidemiological studies underway, we must continue to act to encourage radiological protection. Before considering the action to take and without under-estimating the risks, it is important to remember that a computed tomography investigation is conducted in patients, and not in individuals in good health. Acting to provide patients with protection from radiation means involving all those concerned with justifying it, with substituting it, and with optimising it. For some years

  17. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  18. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Golimbu, C.; Bonamo, J.

    1984-01-01

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  19. Comparison of effects of ProTaper, HeroShaper, and Gates Glidden Burs on cervical dentin thickness and root canal volume by using multislice computed tomography.

    Science.gov (United States)

    Mahran, Abeer H; AboEl-Fotouh, Mona M

    2008-10-01

    The purpose of this study was to compare the effects of 3 different instruments used to prepare curved root canals on the remaining cervical dentin thickness and total amount of dentin removed from root canals during instrumentation by using multislice computed tomography. Mesiobuccal canals of 45 mandibular first molars with curvature between 30-40 degrees were divided into 3 equal groups: ProTaper, Hero Shaper, and Gates Glidden Bur with Flex-R hand file. Cervical dentin thickness and canal volume were measured before and after instrumentation by using multislice computed tomography and image analysis software. The results indicated that ProTaper removed significantly less cervical dentin from distal wall of the root (dangerous zone) than HeroShaper and Gates Glidden Bur (P ProTaper system (P < .05).

  20. Computed tomography of pelvic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kimoto, Makoto; Hashimoto, Keiji; Hiraki, Yoshio

    1984-12-01

    Plain x-ray and computed tomographic (CT) findings were compared in 7 patients with pelvic fractures (2 males and 5 females) aged between 35 and 50 year. Plain x-rays had a higher sensitivity than CT in detecting fractures of the ischiatic and pubic ramuses, and deviation of bone fragments. CT was superior to plain x-rays near the acetabulum and in detecting deviation of bone fragments. Although there were no differences between the two modalities in detecting fractures of the wing of ilium, CT was more useful than plain x-rays in visualizing deviation of bone fragments. CT clearly visualized not only fractures but also injuries of the soft tissues, such as pelvic viscera and muscles, and the presence of hematoma. CT seems to be a useful method for observing the condition and process of pelvic injuries and for deciding treatment protocols.

  1. Prediction of effectiveness of shunting in patients with normal pressure hydrocephalus by cerebral blood flow measurement and computed tomography cisternography

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Chia-Cheng; Kuwana, Nobumasa; Ito, Susumu; Ikegami, Tadashi [Yokohama Minami Kyosai Hospital (Japan)

    1999-11-01

    Measurement of cerebral blood flow (CBF) and computed tomography (CT) cisternography were performed in 37 patients with a tentative diagnosis of normal pressure hydrocephalus (NPH) to predict their surgical outcome. The mean CBF of the whole brain was measured quantitatively by single photon emission computed tomography with technetium-99m-hexamethylpropylene amine oxime before surgery. The results of CT cisternography were classified into four patients: type I, no ventricular stasis at 24 hours; type II, no ventricular stasis with delayed clearance of cerebral blush; type III, persistent ventricular stasis with prominent cerebral blush; type IV, persistent ventricular stasis with diminished cerebral blush and/or asymmetrical filling of the sylvian fissures. The mean CBF was significantly lower than that of age-matched controls (p<0.005). Patients with a favorable outcome had a significantly higher mean CBF than patients with an unfavorable outcome (p<0.005). Patients with the type I pattern did not respond to shunting. Some patients with type II and III patterns responded to shunting but improvement was unsatisfactory. Patients with type IV pattern responded well to shunting, and those with a mean CBF of 35 ml/100 g/min or over achieved a favorable outcome. The combination of CBF measurement and CT cisternography can improve the prediction of surgical outcome in patients with suspected NPH. (author)

  2. Effect of Saline Pushing after Contrast Material Injection in Abdominal Multidetector Computed Tomography with the Use of Different Iodine Concentrations

    International Nuclear Information System (INIS)

    Tatsugami, F.; Matsuki, M.; Kani, H.; Tanikake, M.; Miyao, M.; Yoshikawa, S.; Narabayashi, I.

    2006-01-01

    Purpose: To investigate whether saline pushing after contrast material improves hepatic vascular and parenchymal enhancement, and to determine whether this technique permits decreased contrast material concentration. Material and Methods: 120 patients who underwent hepatic multidetector computed tomography were divided randomly into four groups (Groups A-D): receiving 100 ml of contrast material (300 mgI/ml) only (A) or with 50 ml of saline solution (B); or 100 ml of contrast material (350 mgI/ml) only (C) or with 50 ml of saline solution (D). Computed tomography (CT) values of the aorta in the arterial phase, the portal vein in the portal venous inflow phase, and the liver in the hepatic phase were measured. Visualization of the hepatic artery and the portal vein by 3D CT angiography was evaluated as well. Results: Although the enhancement values of the aorta were not improved significantly with saline pushing, they continued at a high level to the latter slices with saline pushing. The enhancement value of the portal vein increased significantly and CT portography was improved with saline pushing. The enhancement value of the liver was not improved significantly using saline pushing. In a comparison between groups B and C, the enhancement values of the aorta and portal vein and the visualization of CT arteriography and portography were not statistically different. Conclusion: The saline pushing technique can contribute to a decrease in contrast material concentration for 3D CT arteriography and portography

  3. Prediction of effectiveness of shunting in patients with normal pressure hydrocephalus by cerebral blood flow measurement and computed tomography cisternography

    International Nuclear Information System (INIS)

    Chang, Chia-Cheng; Kuwana, Nobumasa; Ito, Susumu; Ikegami, Tadashi

    1999-01-01

    Measurement of cerebral blood flow (CBF) and computed tomography (CT) cisternography were performed in 37 patients with a tentative diagnosis of normal pressure hydrocephalus (NPH) to predict their surgical outcome. The mean CBF of the whole brain was measured quantitatively by single photon emission computed tomography with technetium-99m-hexamethylpropylene amine oxime before surgery. The results of CT cisternography were classified into four patients: type I, no ventricular stasis at 24 hours; type II, no ventricular stasis with delayed clearance of cerebral blush; type III, persistent ventricular stasis with prominent cerebral blush; type IV, persistent ventricular stasis with diminished cerebral blush and/or asymmetrical filling of the sylvian fissures. The mean CBF was significantly lower than that of age-matched controls (p<0.005). Patients with a favorable outcome had a significantly higher mean CBF than patients with an unfavorable outcome (p<0.005). Patients with the type I pattern did not respond to shunting. Some patients with type II and III patterns responded to shunting but improvement was unsatisfactory. Patients with type IV pattern responded well to shunting, and those with a mean CBF of 35 ml/100 g/min or over achieved a favorable outcome. The combination of CBF measurement and CT cisternography can improve the prediction of surgical outcome in patients with suspected NPH. (author)

  4. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  5. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography.

    Science.gov (United States)

    Trattner, Sigal; Halliburton, Sandra; Thompson, Carla M; Xu, Yanping; Chelliah, Anjali; Jambawalikar, Sachin R; Peng, Boyu; Peters, M Robert; Jacobs, Jill E; Ghesani, Munir; Jang, James J; Al-Khalidi, Hussein; Einstein, Andrew J

    2018-01-01

    This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor of 0.014 mSv·mGy -1 cm -1 . Accurate estimation of ED from cardiac CT scans is essential to meaningfully compare the benefits and risks of different cardiac imaging strategies and optimize test and protocol selection. Presently, ED from cardiac CT is generally estimated by multiplying a scanner-reported parameter, the dose-length product, by a k-factor which was determined for noncardiac chest CT, using single-slice scanners and a superseded definition of ED. Metal-oxide-semiconductor field-effect transistor radiation detectors were positioned in organs of anthropomorphic phantoms, which were scanned using all cardiac protocols, 120 clinical protocols in total, on 12 CT scanners representing the spectrum of scanners from 5 manufacturers (GE, Hitachi, Philips, Siemens, Toshiba). Organ doses were determined for each protocol, and ED was calculated as defined in International Commission on Radiological Protection Publication 103. Effective doses and scanner-reported dose-length products were used to determine k-factors for each scanner model and protocol. k-Factors averaged 0.026 mSv·mGy -1 cm -1 (95% confidence interval: 0.0258 to 0.0266) and ranged between 0.020 and 0.035 mSv·mGy -1 cm -1 . The standard chest k-factor underestimates ED by an average of 46%, ranging from 30% to 60%, depending on scanner, mode, and tube potential. Factors were higher for prospective axial versus retrospective helical scan modes, calcium scoring versus coronary CTA, and higher (100 to 120 kV) versus lower (80 kV) tube potential and varied among scanner models (range of average k-factors: 0.0229 to 0.0277 mSv·mGy -1 cm -1 ). Cardiac k

  6. Low-Dose Chest Computed Tomography for Lung Cancer Screening Among Hodgkin Lymphoma Survivors: A Cost-Effectiveness Analysis

    International Nuclear Information System (INIS)

    Wattson, Daniel A.; Hunink, M.G. Myriam; DiPiro, Pamela J.; Das, Prajnan; Hodgson, David C.; Mauch, Peter M.; Ng, Andrea K.

    2014-01-01

    Purpose: Hodgkin lymphoma (HL) survivors face an increased risk of treatment-related lung cancer. Screening with low-dose computed tomography (LDCT) may allow detection of early stage, resectable cancers. We developed a Markov decision-analytic and cost-effectiveness model to estimate the merits of annual LDCT screening among HL survivors. Methods and Materials: Population databases and HL-specific literature informed key model parameters, including lung cancer rates and stage distribution, cause-specific survival estimates, and utilities. Relative risks accounted for radiation therapy (RT) technique, smoking status (>10 pack-years or current smokers vs not), age at HL diagnosis, time from HL treatment, and excess radiation from LDCTs. LDCT assumptions, including expected stage-shift, false-positive rates, and likely additional workup were derived from the National Lung Screening Trial and preliminary results from an internal phase 2 protocol that performed annual LDCTs in 53 HL survivors. We assumed a 3% discount rate and a willingness-to-pay (WTP) threshold of $50,000 per quality-adjusted life year (QALY). Results: Annual LDCT screening was cost effective for all smokers. A male smoker treated with mantle RT at age 25 achieved maximum QALYs by initiating screening 12 years post-HL, with a life expectancy benefit of 2.1 months and an incremental cost of $34,841/QALY. Among nonsmokers, annual screening produced a QALY benefit in some cases, but the incremental cost was not below the WTP threshold for any patient subsets. As age at HL diagnosis increased, earlier initiation of screening improved outcomes. Sensitivity analyses revealed that the model was most sensitive to the lung cancer incidence and mortality rates and expected stage-shift from screening. Conclusions: HL survivors are an important high-risk population that may benefit from screening, especially those treated in the past with large radiation fields including mantle or involved-field RT. Screening

  7. Low-Dose Chest Computed Tomography for Lung Cancer Screening Among Hodgkin Lymphoma Survivors: A Cost-Effectiveness Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wattson, Daniel A., E-mail: dwattson@partners.org [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Hunink, M.G. Myriam [Departments of Radiology and Epidemiology, Erasmus Medical Center, Rotterdam, the Netherlands and Center for Health Decision Science, Harvard School of Public Health, Boston, Massachusetts (United States); DiPiro, Pamela J. [Department of Imaging, Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Das, Prajnan [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hodgson, David C. [Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Mauch, Peter M.; Ng, Andrea K. [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2014-10-01

    Purpose: Hodgkin lymphoma (HL) survivors face an increased risk of treatment-related lung cancer. Screening with low-dose computed tomography (LDCT) may allow detection of early stage, resectable cancers. We developed a Markov decision-analytic and cost-effectiveness model to estimate the merits of annual LDCT screening among HL survivors. Methods and Materials: Population databases and HL-specific literature informed key model parameters, including lung cancer rates and stage distribution, cause-specific survival estimates, and utilities. Relative risks accounted for radiation therapy (RT) technique, smoking status (>10 pack-years or current smokers vs not), age at HL diagnosis, time from HL treatment, and excess radiation from LDCTs. LDCT assumptions, including expected stage-shift, false-positive rates, and likely additional workup were derived from the National Lung Screening Trial and preliminary results from an internal phase 2 protocol that performed annual LDCTs in 53 HL survivors. We assumed a 3% discount rate and a willingness-to-pay (WTP) threshold of $50,000 per quality-adjusted life year (QALY). Results: Annual LDCT screening was cost effective for all smokers. A male smoker treated with mantle RT at age 25 achieved maximum QALYs by initiating screening 12 years post-HL, with a life expectancy benefit of 2.1 months and an incremental cost of $34,841/QALY. Among nonsmokers, annual screening produced a QALY benefit in some cases, but the incremental cost was not below the WTP threshold for any patient subsets. As age at HL diagnosis increased, earlier initiation of screening improved outcomes. Sensitivity analyses revealed that the model was most sensitive to the lung cancer incidence and mortality rates and expected stage-shift from screening. Conclusions: HL survivors are an important high-risk population that may benefit from screening, especially those treated in the past with large radiation fields including mantle or involved-field RT. Screening

  8. Low-dose chest computed tomography for lung cancer screening among Hodgkin lymphoma survivors: a cost-effectiveness analysis.

    Science.gov (United States)

    Wattson, Daniel A; Hunink, M G Myriam; DiPiro, Pamela J; Das, Prajnan; Hodgson, David C; Mauch, Peter M; Ng, Andrea K

    2014-10-01

    Hodgkin lymphoma (HL) survivors face an increased risk of treatment-related lung cancer. Screening with low-dose computed tomography (LDCT) may allow detection of early stage, resectable cancers. We developed a Markov decision-analytic and cost-effectiveness model to estimate the merits of annual LDCT screening among HL survivors. Population databases and HL-specific literature informed key model parameters, including lung cancer rates and stage distribution, cause-specific survival estimates, and utilities. Relative risks accounted for radiation therapy (RT) technique, smoking status (>10 pack-years or current smokers vs not), age at HL diagnosis, time from HL treatment, and excess radiation from LDCTs. LDCT assumptions, including expected stage-shift, false-positive rates, and likely additional workup were derived from the National Lung Screening Trial and preliminary results from an internal phase 2 protocol that performed annual LDCTs in 53 HL survivors. We assumed a 3% discount rate and a willingness-to-pay (WTP) threshold of $50,000 per quality-adjusted life year (QALY). Annual LDCT screening was cost effective for all smokers. A male smoker treated with mantle RT at age 25 achieved maximum QALYs by initiating screening 12 years post-HL, with a life expectancy benefit of 2.1 months and an incremental cost of $34,841/QALY. Among nonsmokers, annual screening produced a QALY benefit in some cases, but the incremental cost was not below the WTP threshold for any patient subsets. As age at HL diagnosis increased, earlier initiation of screening improved outcomes. Sensitivity analyses revealed that the model was most sensitive to the lung cancer incidence and mortality rates and expected stage-shift from screening. HL survivors are an important high-risk population that may benefit from screening, especially those treated in the past with large radiation fields including mantle or involved-field RT. Screening may be cost effective for all smokers but possibly not

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... in CT scans should have no immediate side effects. Risks The risk of serious allergic reaction to contrast materials that contain iodine is rare in children, and almost always mild, and radiology departments are ...

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Using a multidetector CT unit to examine ... CT scans should have no immediate side effects. Risks The risk of serious allergic reaction to contrast ...

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... in CT scans should have no immediate side effects. Risks The risk of serious allergic reaction to ... Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  13. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  14. Soil structure changes evaluated with computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz Fernando

    2010-01-01

    The objective of this work was to evaluate in millimetric scale changes in soil bulk density and porosity, using the gamma-ray computed tomography in soil samples with disturbed structure due to wetting and drying (W-D) cycles. Soil samples with 98.1 cm 3 were sieved using a 2 mm mesh and homogeneously packed in PVC cylinders. Soil samples were submitted to 1, 2, and 3 W-D cycles. Control samples were not submitted to W-D cycles. After repetitions of W-D cycles, soil sample porosity decreased and soil layers became denser. Computed tomography allowed a continuous analysis of soil bulk density and also soil porosity along millimetric (0.08 cm) layers, what cannot be provided by traditional methods used in soil physics. (author)

  15. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Vymazal, J.; Bauer, J.

    1983-01-01

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  16. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  17. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  20. The clinical feasibility and effect of online cone beam computer tomography-guided intensity-modulated radiotherapy for nasopharyngeal cancer

    International Nuclear Information System (INIS)

    Wang Jin; Bai Sen; Chen Nianyong; Xu Feng; Jiang Xiaoqin; Li Yan; Xu Qingfeng; Shen Yali; Zhang Hong; Gong Youling; Zhong Renming; Jiang Qingfeng

    2009-01-01

    Background and purpose: Online adaptive correction in image-guided intensity-modulated radiotherapy appeared to be a promising approach for precision radiation treatment in head and neck tumors. This protocol was designed to evaluate the clinical feasibility and effect of online cone beam computed tomography (CBCT) guidance in IMRT of nasopharyngeal cancer (NPC). Methods and materials: The Elekta Synergy system, which integrates an X-ray volumetric imager (XVI), was used to deliver radiation treatment for 22 cases of NPC. The acquired CBCT was registered to the planning CT for online and offline analysis. The systematic and random setup errors, as well as planning target volume (PTV) margin, were calculated at different correction threshold levels. The impact of online setup correction on dosimetry was evaluated by simulation of pre-correction errors. Results: The correction-of-setup-errors frequencies for 1, 2 and 3 mm thresholds were 41.3-53.9%, 12.7-21.2% and 6.3-10.3%, respectively. Online correction was effective at the 2 mm threshold level for all three axes. The pre-correction systematic errors for the whole group ranged 1.1-1.3 mm, and the random errors were also 1.1-1.3 mm. After online correction, the systematic and random errors ranged 0.4-0.5 mm and 0.7-0.8 mm, respectively, in the three directions. The PTV margins for the pre-correction, pretreatment and post-treatment positions were 3.5-4.2 mm, 1.6-1.8 mm and 2.5-3.2 mm, respectively, in three directions. Analysis of hypothetical dosimetric change due to a translational isocenter shift of 3 mm showed that if no correction was applied, the mean maximum dose to both the brain stem and spinal cord would be increased by 10 Gy, the mean dose to the left and right parotids would be increased by 7.8 and 8.5 Gy, respectively, and the dose to target volumes would be decreased: 4 Gy for 95% GTV and 5.6 Gy for 95% CTV 60. Conclusions: CBCT-based online correction increased the accuracy of IMRT for NPC and

  1. Xenon as an adjunct in computed tomography

    International Nuclear Information System (INIS)

    Kendall, B.E.; Radue, E.W.; Zilkha, E.; Loh, L.

    1979-01-01

    Nonradioactive xenon was used for enhancement in computed tomography in a series of 18 patients requiring general anesthesia. The method and results are described. The properties of xenon are radically different from those of intravenous iodides, and the enhancement patterns demonstrate different aspects of both normal and abnormal tissues. In our limited experience, it has been of value in those isodense and low attenuation lesions that have not enhanced after intravenous Conray. (orig.) 891 MG/orig. 892 MB [de

  2. Computed tomography of the eye and orbit

    International Nuclear Information System (INIS)

    Hammerschlag, S.B.; Hesselink, J.R.; Weber, A.L.

    1982-01-01

    This book is the product of the evolution of computed tomography (CT) into subspecialization and the need for one source of information for the busy radiologist. The authors have succeeded in providing a readable overview of orbital CT as well as a reference book. The book is divided into seven major catagories of pathology (Neurofibromatosis, Primary Orbital Neoplasms, Secondary and Metastic Tumors of the Orbit, Vascular Disorders, Inflammatory Disease, Occular Lesions, and Trauma) after separate discussions of anatomy and technique

  3. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias; Furtwaengler, Alex

    2003-01-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST ( 5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  4. Computed tomography in opportunistic lung infections

    International Nuclear Information System (INIS)

    Hartelius, H.

    1988-01-01

    Chest radiography in two teenage boys, one with Wiscott-Aldrich's syndrome and one with acute lymphatic leucemia in remission showed increased interstitial pattern. In both computed tomography (CT) of the lungs showed heavy interstitial pneumonia, rather different in appearance but in both cases equal to the CT findings in opportunistic lung infections known from immunoincompetent patients with for instance pneumocystis carinii and/or cytomegalo virus infections. In both patients the CT findings led to lung biopsy establishing the etiologic agent. (orig.)

  5. Cranial computed tomography of the neurofibromatosis

    International Nuclear Information System (INIS)

    Fukuda, Teruo; Inoue, Yuichi; Shibakiri, Ippei

    1981-01-01

    The computed tomography (CT) was performed in 10 cases of neurofibromatosis. The CT scan showed the abnormal findings in 8 cases out of 10. Skull lesions were noted in 3 cases and intracranial tumors were found in 5 among which multiple neoplasms were seen in 3. Although reported cases were not large enough in number, the incidence and variety of the tumors were similar to others reported before CT era. (author)

  6. Computed tomography manifestations of peritoneal diseases

    International Nuclear Information System (INIS)

    Gordon, K.; Lee, W.K.; Hennessy, O.

    2005-01-01

    The peritoneal cavity is a potential space that is divided by the peritoneal reflections into various complex subspaces. It can be involved in many disease processes including developmental, inflammatory, neoplastic and traumatic conditions. Computed tomography is highly sensitive and consistent in detecting peritoneal pathology. This pictorial essay aims to emphasize and illustrate the CT features of the spectrum of peritoneal diseases. Copyright (2005) Blackwell Science Pty Ltd

  7. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  8. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    International Nuclear Information System (INIS)

    Smith, S.L.; Hampson, F.; Duxbury, M.; Rae, D.M.; Sinclair, M.T.

    2008-01-01

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications

  9. Fatty kidney diagnosed by mortem computed tomography

    DEFF Research Database (Denmark)

    Leth, P. M.

    2016-01-01

    Subnuclear vacuolization of the renal tubular epithelium is indicative of diabetic and alcoholic ketoacidosis and has also been proposed as a postmortem marker for hypothermia. We present for the first time a fatal case of ketoacidosis in combination with exposure where a suspicion of these diagn...... of these diagnoses was raised by a marked radiolucency of the kidneys at post-mortem computed tomography (PMCT). © 2015 Elsevier Ltd....

  10. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  11. Computed tomography in intracranial malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, S; Odake, G; Fujimoto, M; Yamaki, T; Mizukawa, N [Kyoto Prefectural Univ. of Medicine (Japan)

    1978-09-01

    Malignant lymphoma of the central nervous system has been found more and more often in recent years, partly because of the increased use of radiation and such drugs as steroids and antibiotics. However, the definite diagnosis of this disease is difficult until histological verification has been done by operation or autopsy. Since the revolutionary development of computed tomography, however, several reports have been presented, on the computed tomography of malignant lymphoma of the thorax and abdomen. Nevertheless, only a few cases of intracranial malignant lymphoma have been reported. The purpose of this paper, using four patients, is to emphasize the value of computed tomography in the diagnosis of intracranial malignant lymphoma. The characteristic CT findings of intracranial malignant lymphoma may be summarized follows: (1) the tumors are demonstrated to be well-defined, nodular-shaped, and homogenous isodensity - or slightly high-density - lesions in plain scans, and the tumors homogenously increase in density upon contrast enhancement; (2) the disease always has multifocal intracranial lesions, which are shown simultaneously or one after another, and (3) perifocal edema is prominent around the tumors in the cerebral hemisphere.

  12. Computed tomography in neurosurgical practice

    International Nuclear Information System (INIS)

    Handa, Jyoji; Okamoto, Kazuo; Nakano, Yoshihisa.

    1980-01-01

    CT diagnosis of intracranial diseases such as tumors, vascular disorder, trauma, infectious diseases, and congenital malformations which were clinically important diseases in neurosurgery was stated briefly. CT was the most suitable not only for the diagnosis of these diseases but also for follow-up of effects of neurosurgery and radiotherapy or chemotherapy, and for discovery of various complications and sequelae. Moreover, CT are applied to establishment of radiation fields and radiation doses for radiotherapy and to biopsy and paracentesis drainage of cysts under CT control. The usefulness of CT for diagnosis of diseases of spinal cord, spine and spinal canal have been already established. The usefulness of CT for neurosurgery including dynamic and functional analysis by the development of apparatuses is expected. (Tsunoda, M.)

  13. Spondylolysis studied with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Grogan, J.P.; Hemminghytt, S.; Williams, A.L.; Carrera, G.F.; Haughton, V.M.

    1982-12-01

    Spinal CT scans, plain radiographs, and medical records of 81 patients with an abnormal pars interarticularis were reviewed to define the CT criteria for spondylolysis. In many cases, it was difficult to detect because it simulated the adjacent facet joints; however, it could be differentiated by careful analysis of the section level and the contiguous facet joints, which usually had regular cortical surfaces (in contrast to the pars defects).Spondylolysis was evident on the lateral localizer image in most cases. In some patients the pars appeared abnormally narrow and elongated or sclerotic as well as interrupted. In a few cases, CT demonstrated a pars defect which was not effectively shown by the plain radiographs. In one patient, a herniated disk was also seen.

  14. Spondylolysis studied with computed tomography

    International Nuclear Information System (INIS)

    Grogan, J.P.; Hemminghytt, S.; Williams, A.L.; Carrera, G.F.; Haughton, V.M.

    1982-01-01

    Spinal CT scans, plain radiographs, and medical records of 81 patients with an abnormal pars interarticularis were reviewed to define the CT criteria for spondylolysis. In many cases, it was difficult to detect because it simulated the adjacent facet joints; however, it could be differentiated by careful analysis of the section level and the contiguous facet joints, which usually had regular cortical surfaces (in contrast to the pars defects).Spondylolysis was evident on the lateral localizer image in most cases. In some patients the pars appeared abnormally narrow and elongated or sclerotic as well as interrupted. In a few cases, CT demonstrated a pars defect which was not effectively shown by the plain radiographs. In one patient, a herniated disk was also seen

  15. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  16. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  17. Effect of lung volume on airway luminal area assessed by computed tomography in chronic obstructive pulmonary disease.

    Directory of Open Access Journals (Sweden)

    Kenta Kambara

    Full Text Available BACKGROUND: Although airway luminal area (Ai is affected by lung volume (LV, how is not precisely understood. We hypothesized that the effect of LV on Ai would differ by airway generation, lung lobe, and chronic obstructive pulmonary disease (COPD severity. METHODS: Sixty-seven subjects (15 at risk, 18, 20, and 14 for COPD stages 1, 2, and 3 underwent pulmonary function tests and computed tomography scans at full inspiration and expiration (at functional residual capacity. LV and eight selected identical airways were measured in the right lung. Ai was measured at the mid-portion of the 3(rd, the segmental bronchus, to 6(th generation of the airways, leading to 32 measurements per subject. RESULTS: The ratio of expiratory to inspiratory LV (LV E/I ratio and Ai (Ai E/I ratio was defined for evaluation of changes. The LV E/I ratio increased as COPD severity progressed. As the LV E/I ratio was smaller, the Ai E/I ratio was smaller at any generation among the subjects. Overall, the Ai E/I ratios were significantly smaller at the 5(th (61.5% and 6(th generations (63.4% and than at the 3(rd generation (73.6%, p<0.001 for each, and also significantly lower in the lower lobe than in the upper or middle lobe (p<0.001 for each. And, the Ai E/I ratio decreased as COPD severity progressed only when the ratio was corrected by the LV E/I ratio (at risk v.s. stage 3 p<0.001, stage 1 v.s. stage 3 p<0.05. CONCLUSIONS: From full inspiration to expiration, the airway luminal area shrinks more at the distal airways compared with the proximal airways and in the lower lobe compared with the other lobes. Generally, the airways shrink more as COPD severity progresses, but this phenomenon becomes apparent only when lung volume change from inspiration to expiration is taken into account.

  18. The effect of inhaled corticosteroids on the development of emphysema in smokers assessed by annual computed tomography.

    Science.gov (United States)

    Shaker, Saher B; Dirksen, Asger; Ulrik, Charlotte S; Hestad, Marianne; Stavngaard, Trine; Laursen, Lars C; Maltbaek, Niels; Clementsen, Paul; Skjaerbaek, Nanna; Nielsen, Lars; Stoel, Berend; Skovgaard, Lene T; Tonnesen, Philip

    2009-04-01

    The objective was to evaluate the effect of inhaled corticosteroids on disease progression in smokers with moderate to severe chronic obstructive pulmonary disease (COPD), as assessed by annual computed tomography (CT) using lung density (LD) measurements. Two hundred and fifty-four current smokers with COPD were randomised to treatment with either an inhaled corticosteroids (ICS), budesonide 400 microg bid, or placebo. COPD was defined as FEV(1) < or = 70% pred, FEV(1)/FVC < or = 60% and no reversibility to beta(2)-agonists and oral corticosteroids. The patients were followed for 2-4 years with biannual spirometry and annual CT and comprehensive lung function tests (LFT). CT images were analysed using Pulmo-CMS software. LD was derived from a pixel-density histogram of the whole lung as the 15th percentile density (PD15) and the relative area of emphysema at a threshold of -910 Hounsfield units (RA-910), and both were volume-adjusted to predicted total lung capacity. At baseline, mean age was 64 years and 64 years; mean number of pack-years was 56 and 56; mean FEV(1) was 1.53 L (51% pred) and 1.53 L (53% pred); mean PD15 was 103 g/L and 104 g/L; and mean RA-910 was 14% and 13%, respectively, for the budesonide and placebo groups. The annual fall in PD15 was -1.12 g/L in the budesonide group and -1.81 g/L in the placebo group (p = 0.09); the annual increase in RA-910 was 0.4% in the budesonide group and 1.1% in the placebo group (p = 0.02). There was no difference in annual decline in FEV(1) between ICS (-54 mL) and placebo (-56 mL) (p = 0.89). Long-term budesonide inhalation shows a non-significant trend towards reducing the progression of emphysema as determined by the CT-derived 15th percentile lung density from annual CT scans in current smokers with moderate to severe COPD.

  19. TU-F-CAMPUS-J-05: Effect of Uncorrelated Noise Texture On Computed Tomography Quantitative Image Features

    International Nuclear Information System (INIS)

    Oliver, J; Budzevich, M; Moros, E; Zhang, G; Hunt, D

    2015-01-01

    Purpose: To investigate the relationship between quantitative image features (i.e. radiomics) and statistical fluctuations (i.e. electronic noise) in clinical Computed Tomography (CT) using the standardized American College of Radiology (ACR) CT accreditation phantom and patient images. Methods: Three levels of uncorrelated Gaussian noise were added to CT images of phantom and patients (20) acquired in static mode and respiratory tracking mode. We calculated the noise-power spectrum (NPS) of the original CT images of the phantom, and of the phantom images with added Gaussian noise with means of 50, 80, and 120 HU. Concurrently, on patient images (original and noise-added images), image features were calculated: 14 shape, 19 intensity (1st order statistics from intensity volume histograms), 18 GLCM features (2nd order statistics from grey level co-occurrence matrices) and 11 RLM features (2nd order statistics from run-length matrices). These features provide the underlying structural information of the images. GLCM (size 128x128) was calculated with a step size of 1 voxel in 13 directions and averaged. RLM feature calculation was performed in 13 directions with grey levels binning into 128 levels. Results: Adding the electronic noise to the images modified the quality of the NPS, shifting the noise from mostly correlated to mostly uncorrelated voxels. The dramatic increase in noise texture did not affect image structure/contours significantly for patient images. However, it did affect the image features and textures significantly as demonstrated by GLCM differences. Conclusion: Image features are sensitive to acquisition factors (simulated by adding uncorrelated Gaussian noise). We speculate that image features will be more difficult to detect in the presence of electronic noise (an uncorrelated noise contributor) or, for that matter, any other highly correlated image noise. This work focuses on the effect of electronic, uncorrelated, noise and future work shall

  20. Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation.

    Science.gov (United States)

    Chow, James C L; Leung, Michael K K; Islam, Mohammad K; Norrlinger, Bernhard D; Jaffray, David A

    2008-01-01

    The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnr code for 100, 120, 130, and 140 kVp energies. An in-house graphical user interface called DOSCTP (DOSXYZnrc-based) developed using MATLAB was used to calculate the dose distributions due to a 360 degrees photon arc from the CBCT beam with the same patient CT image sets as used in Pinnacle. The two calculated dose distributions were added together by setting the CBCT doses equal to 1%, 1.5%, 2%, and 2.5% of the prescription dose of the prostate IMRT. The prostate plan and the summed dose distributions were then processed in the CERR platform to determine the dose-volume histograms (DVHs) of the regions of interest. Moreover, dose profiles along the x- and y-axes crossing the isocenter with and without addition of the CBCT dose were determined. It was found that the added doses due to CBCT are most significant at the femur heads. Higher doses were found at the bones for a relatively low energy CBCT beam such as 100 kVp. Apart from the bones, the CBCT dose was observed to be most concentrated on the anterior and posterior side of the patient anatomy. Analysis of the DVHs for the prostate and other critical tissues showed that they vary only slightly with the added CBCT dose at different beam energies. On the other hand, the changes of the DVHs for the femur heads due to the CBCT dose and beam energy were more significant than those of rectal and bladder wall. By analyzing the vertical and horizontal dose profiles crossing the femur heads and isocenter, with and without the CBCT dose equal to 2% of the

  1. Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chow, James C. L.; Leung, Michael K. K.; Islam, Mohammad K.; Norrlinger, Bernhard D.; Jaffray, David A.

    2008-01-01

    The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle3 treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnrc code for 100, 120, 130, and 140 kVp energies. An in-house graphical user interface called DOSCTP (DOSXYZnrc-based) developed using MATLAB was used to calculate the dose distributions due to a 360 deg. photon arc from the CBCT beam with the same patient CT image sets as used in Pinnacle3. The two calculated dose distributions were added together by setting the CBCT doses equal to 1%, 1.5%, 2%, and 2.5% of the prescription dose of the prostate IMRT. The prostate plan and the summed dose distributions were then processed in the CERR platform to determine the dose-volume histograms (DVHs) of the regions of interest. Moreover, dose profiles along the x- and y-axes crossing the isocenter with and without addition of the CBCT dose were determined. It was found that the added doses due to CBCT are most significant at the femur heads. Higher doses were found at the bones for a relatively low energy CBCT beam such as 100 kVp. Apart from the bones, the CBCT dose was observed to be most concentrated on the anterior and posterior side of the patient anatomy. Analysis of the DVHs for the prostate and other critical tissues showed that they vary only slightly with the added CBCT dose at different beam energies. On the other hand, the changes of the DVHs for the femur heads due to the CBCT dose and beam energy were more significant than those of rectal and bladder wall. By analyzing the vertical and horizontal dose profiles crossing the femur heads and isocenter, with and without the CBCT dose equal to 2% of the

  2. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Tingey, D.R.C.

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors)

  3. Computed tomography with selectable image resolution

    International Nuclear Information System (INIS)

    Dibianca, F.A.; Dallapiazza, D.G.

    1981-01-01

    A computed tomography system x-ray detector has a central group of half-width detector elements and groups of full-width elements on each side of the central group. To obtain x-ray attenuation data for whole body layers, the half-width elements are switched effectively into paralleled pairs so all elements act like full-width elements and an image of normal resolution is obtained. For narrower head layers, the elements in the central group are used as half-width elements so resolution which is twice as great as normal is obtained. The central group is also used in the half-width mode and the outside groups are used in the full-width mode to obtain a high resolution image of a body zone within a full body layer. In one embodiment data signals from the detector are switched by electronic multiplexing and in another embodiment a processor chooses the signals for the various kinds of images that are to be reconstructed. (author)

  4. Cranial computed tomography in infantile spasms

    International Nuclear Information System (INIS)

    Howitz, P.; Neergaard, K.; Pedersen, H.

    1990-01-01

    Out of 109 children with infantile spasms (IS), prospectively tested during the years 1976 to 1979 in Denmark, 52 children were examined by cranial computed tomography (CT). The classification of IS into cryptogenic (CR), symptomatic (SY) and doubtful (DO) was done clinically without considering the CT-finding. Sixty per cent of the scannings were abnormal. Only 6/30 (20%) of the children in ACTH treatment were found to develop cerebral atrophy which means that this finding is not an obligatory side-effect of ACTH treatment of children with IS. Normal CT-findings were found in 50% of the CR and 50% of the SY + DO-groups, and could not be used as a prognostic tool for estimating the mental development. This was also the case for children with cerebral atrophy. Abnormal CT-findings (minus atrophy) were highly correlated to the group with clinical symptoms and indicate an extremely unsatisfying long-term mental prognosis. CT-scanning is a valuable tool for the examination of clearing children with infantile spasms. (authors)

  5. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  6. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  7. The effects of simulating a realistic eye model on the eye dose of an adult male undergoing head computed tomography.

    Science.gov (United States)

    Akhlaghi, Parisa; Ebrahimi-Khankook, Atiyeh; Vejdani-Noghreiyan, Alireza

    2017-05-01

    In head computed tomography, radiation upon the eye lens (as an organ with high radiosensitivity) may cause lenticular opacity and cataracts. Therefore, quantitative dose assessment due to exposure of the eye lens and surrounding tissue is a matter of concern. For this purpose, an accurate eye model with realistic geometry and shape, in which different eye substructures are considered, is needed. To calculate the absorbed radiation dose of visual organs during head computed tomography scans, in this study, an existing sophisticated eye model was inserted at the related location in the head of the reference adult male phantom recommended by the International Commission on Radiological Protection (ICRP). Then absorbed doses and distributions of energy deposition in different parts of this eye model were calculated and compared with those based on a previous simple eye model. All calculations were done using the Monte Carlo code MCNP4C for tube voltages of 80, 100, 120 and 140 kVp. In spite of the similarity of total dose to the eye lens for both eye models, the dose delivered to the sensitive zone, which plays an important role in the induction of cataracts, was on average 3% higher for the sophisticated model as compared to the simple model. By increasing the tube voltage, differences between the total dose to the eye lens between the two phantoms decrease to 1%. Due to this level of agreement, use of the sophisticated eye model for patient dosimetry is not necessary. However, it still helps for an estimation of doses received by different eye substructures separately.

  8. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  9. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. Copyright © 2010. Published by Elsevier Inc.

  10. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  11. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  12. Positron computed tomography: current state, clinical results and future trends

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  13. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-01-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  14. Computed tomography evaluation of autogenous graft in sinus lift surgery

    International Nuclear Information System (INIS)

    Ajzen, Sergio Aron; Moscatiello, Rafael Andrade; Lima, Aida Maria Custodio de; Moscatiello, Vitoria Aparecida Muglia; Helio Kiitiro Yamashita; Mosacatiello, Rafael Muglia; Nishiguchi, Celso Itiro; Alves, Maria Teresa de Seixas

    2001-01-01

    The objective was to quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from apheresis or centrifugation using computed tomography. This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months), with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by apheresis. The results showed that computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. It was concluded that clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants. (author)

  15. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  16. Quantification in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2005-01-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena; 2 - quantification in SPECT, problems and correction methods: Attenuation, scattering, un-stationary spatial resolution, partial volume effect, movement, tomographic reconstruction, calibration; 3 - Synthesis: actual quantification accuracy; 4 - Beyond the activity concentration measurement

  17. Cross-sectional anatomy for computed tomography

    International Nuclear Information System (INIS)

    Farkas, M.L.

    1988-01-01

    This self-study guide recognizes that evaluation and interpretation of CT-images demands a firm understanding of both cross-sectional anatomy and the principles of computed tomography. The objectives of this book are: to discuss the basic principles of CT, to stress the importance of cross-sectional anatomy to CT through study of selected cardinal transverse sections of head, neck, and trunk, to explain orientation and interpretation of CT-images with the aid of corresponding cross-sectional preparations

  18. Computed tomography scans of metastatic hepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Fukuda, Haruyuki; Nemoto, Yutaka [Osaka City Univ. (Japan). Faculty of Medicine

    1984-01-01

    Computed tomography scans of 114 metastatic hepatic tumors were reviewed. Central low density was found in 82 cases (71.9%) and seems to be characteristic to metastatic hepatic tumors. Dynamic CT was performed on 34 cases, and 21 (61.8%) of these had ring enhancement at the arterial phase. Most of metastatic hepatic tumors could be differentiated from hepatocellular carcinoma. However, metastatic hepatic tumors from renal cell carcinoma, renal rhabdomyosarcoma, malignant melanoma and leiomyosarcoma could not be differentiated from hepatocellular carcinoma, even with use of dynamic study.

  19. Computed tomography appearances of sclerosing encapsulating peritonitis

    International Nuclear Information System (INIS)

    George, C.; Al-Zwae, K.; Nair, S.; Cast, J.E.I.

    2007-01-01

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP

  20. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  1. Application of protons to computer tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.; Bradbury, J.N.; Cannon, T.M.; Hutson, R.L.; Laubacher, D.B.; Macek, R.; Paciotti, M.A.; Taylor, C.A.

    1977-01-01

    It was demonstrated that the application of protons to computed tomography can result in a significant dose advantage relative to x rays. Thus, at the same dose as is delivered by contemporary commercial x-ray scanners, a proton scanner could produce reconstructions with a factor of 2 or more improvement in density resolution. Whether such an improvement can result in significantly better diagnoses of human disease is an open question which can only be answered by the implementation of a proton scanner in a clinical situation

  2. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  3. Computed tomography of the spine: Diagnostic exercises

    International Nuclear Information System (INIS)

    Kricun, R.; Kricun, M.E.

    1987-01-01

    The authors' aim is to provide diagnostic challenges and information to improve the readers' ability to interpret computed tomography (CT) scans of the spine. The entire vertebral column and adjacent soft-tissue structures are covered. The authors discuss normal findings, and congenital, traumatic, inflammatory, neoplastic, degenerative, idiopathic, and postoperative findings. Sixty-six case examples are presented, followed by description of the findings. Additional examples are given, and drawings and photographs of specimens are used to illustrate and clarify the pathologic conditions. Other modalities, including their advantages and disadvantages, are illustrated and discussed where appropriate. The relative merits of these modalities are presented

  4. Computed tomography features of small bowel volvulus

    International Nuclear Information System (INIS)

    Loh, Y.H.; Dunn, G.D.

    2000-01-01

    Small bowel volvulus is a cause of acute abdomen and commonly occurs in neonates and young infants. Although it is rare in adults in the Western world,' it is a relatively common surgical emergency in the Middle East, India and Central Africa. It is associated with a mortality rate of 10-67% and, hence, it is important to make an early diagnosis to expedite surgical intervention. Computed tomography has become an important imaging modality in diagnosis and a number of signs have been recognized in a handful of documented case reports. We describe a case of small bowel volvulus that illustrates these important CT signs. Copyright (1999) Blackwell Science Pty Ltd

  5. Computed tomography in neuronal ceroid lipofuscinosis

    International Nuclear Information System (INIS)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neutronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter. (orig.) [de

  6. Unusual causes of obstructive jaundice. Computed tomography

    International Nuclear Information System (INIS)

    Rodriguez, E.; Pombo, F.; Cao, I.; Fernandez, R.; Riba da, M.

    1998-01-01

    The purpose of this study is to present selected computed tomography (CT) images showing unusual causes of obstructive jaundice. We reviewed retrospectively the Ct findings of obstructive jaundice in 227 patients. The most common causes of biliary obstruction were adenocarcinoma of the pancreatic head (n=77) and cholangiocarcinoma (n=65). In 13 cases (5.7%), the etiology of obstructive jaundice was unusual or exceptional: tuberculous adenitis (n=3), obstruction of afferent loop (n=2)signet ring cell adenocarcinoma (n=3); in duodenum, gallbladder and papilla of Water), Mirizzi syndrome (n=1), adenocarcinoma of the hepatic flexure (n=1), choledochal cyst (n=1) and pancreatic lymphoma (n=1). (Author) 13 refs

  7. Electrocardiographic gating in positron emission computed tomography

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Wisenberg, G.; Schelbert, H.R.; Kuhl, D.E.

    1979-01-01

    Electrocardiographic (ECG) synchronized multiple gated data acquisition was employed with positron emission computed tomography (ECT) to obtain images of myocardial blood pool and myocardium. The feasibility and requirements of multiple gated data acquisition in positron ECT were investigated for 13NH3, ( 18 F)-2-fluoro-2-D-deoxyglucose, and ( 11 C)-carboxyhemoglobin. Examples are shown in which image detail is enhanced and image interpretation is facilitated when ECG gating is employed in the data collection. Analysis of count rate data from a series of volunteers indicates that multiple, statistically adequate images can be obtained under a multiple gated data collection format without an increase in administered dose

  8. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  9. Evaluation of patient dose during computed tomography angiography

    International Nuclear Information System (INIS)

    Dafalla, Elamam Yagoob Taha

    2015-10-01

    Computed tomography (CT), is an x-ray procedure that generates high quality cross sectional images of the body, and by comparison to other radiological diagnosis, CT is responsible for higher doses to patients. The evaluation of patient dose from computed tomography for pulmonary examinations the CT is responsible for higher doses to patients. The radiation dose was measured in three hospitals in Khartoum State during March 2015-October 2015 using different CT modalities. The radiation dose was higher at Alzytouna hospital than Daralelaj hospital and Alatebaa hospital was lowest. In this study, the mean effective dose for first hospital was 23.83±3.93 mSv and the mean effective dose for second hospital was 8.94±1.64 mSv and the mean effective dose for third hospital was 2.96±0.79. (author)

  10. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  11. The effects of gas diffusion layers structure on water transportation using X-ray computed tomography based Lattice Boltzmann method

    Science.gov (United States)

    Jinuntuya, Fontip; Whiteley, Michael; Chen, Rui; Fly, Ashley

    2018-02-01

    The Gas Diffusion Layer (GDL) of a Polymer Electrolyte Membrane Fuel Cell (PEMFC) plays a crucial role in overall cell performance. It is responsible for the dissemination of reactant gasses from the gas supply channels to the reactant sites at the Catalyst Layer (CL), and the adequate removal of product water from reactant sites back to the gas channels. Existing research into water transport in GDLs has been simplified to 2D estimations of GDL structures or use virtual stochastic models. This work uses X-ray computed tomography (XCT) to reconstruct three types of GDL in a model. These models are then analysed via Lattice Boltzmann methods to understand the water transport behaviours under differing contact angles and pressure differences. In this study, the three GDL samples were tested over the contact angles of 60°, 80°, 90°, 100°, 120° and 140° under applied pressure differences of 5 kPa, 10 kPa and 15 kPa. By varying the contact angle and pressure difference, it was found that the transition between stable displacement and capillary fingering is not a gradual process. Hydrophilic contact angles in the region of 60°<θ < 90° showed stable displacement properties, whereas contact angles in the region of 100°<θ < 140° displayed capillary fingering characteristics.

  12. Mechanochemical effect on swelling and drug release of natural polymer matrix tablets by X-ray computed tomography.

    Science.gov (United States)

    Hattori, Yusuke; Takaku, Tomomi; Otsuka, Makoto

    2018-03-25

    The relationships between the physicochemical properties of milled starch and drug release from tablets were investigated quantitatively using a drug release kinetic method and X-ray computed tomography (XCT). The samples were prepared from raw β-starch by milling in a planetary ball mill. The tablets, containing 5% theophylline (TH), 94% milled starch, and 1% magnesium stearate, were compressed at 6 kN. The drug-release and gel-forming processes were measured simultaneously using an original dissolution tester with an XCT instrument. Drug release from the tablet was delayed with increasing milling time, because the TH tablet formed a typical gel-layer on the outside of the tablet. The relationship between the crystallinity of milled starch and mean drug release time (MDT) for the TH tablets showed almost a straight inverse proportional relationship. The plots of MDT against area under the curve of the swelling ratio profiles of the TH tablets had a good straight line. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Evaluation of the effect of hemoglobin or hematocrit level on dural sinus density using unenhanced computed tomography.

    Science.gov (United States)

    Lee, Seung Young; Cha, Sang-Hoon; Lee, Sung-Hyun; Shin, Dong-Ick

    2013-01-01

    To identify the relationship between hemoglobin (Hgb) or hematocrit (Hct) level and dural sinus density using unenhanced computed tomography (UECT). Patients who were performed UECT and had records of a complete blood count within 24 hours from UECT were included (n=122). We measured the Hounsfield unit (HU) of the dural sinus at the right sigmoid sinus, left sigmoid sinus and 2 points of the superior sagittal sinus. Quantitative measurement of dural sinus density using the circle regions of interest (ROI) method was calculated as average ROI values at 3 or 4 points. Simple regression analysis was used to evaluate the correlation between mean HU and Hgb or mean HU and Hct. The mean densities of the dural sinuses ranged from 24.67 to 53.67 HU (mean, 43.28 HU). There was a strong correlation between mean density and Hgb level (r=0.832) and between mean density and Hct level (r=0.840). Dural sinus density on UECT is closely related to Hgb and Hct levels. Therefore, the Hgb or Hct levels can be used to determine whether the dural sinus density is within the normal range or pathological conditions such as venous thrombosis.

  14. Computed tomography of juvenile nasopharyngeal angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yoo, Shi Joon; Lee, Yul; Chang, Kee Hyun; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma.

  15. Evaluation of valvular heart diseases with computed tomography

    International Nuclear Information System (INIS)

    Tomoda, Haruo; Hoshiai, Mitsumoto; Matsuyama, Seiya

    1982-01-01

    Forty-two patients with valvular heart diseases were studied with a third-generation computed tomographic system. The cardiac chambers (the atria and ventricles) were evaluated semiquantitatively, and valvular calcification was easily detected with computed tomography. Computed tomography was most valuable in revealing left atrial thrombi which were not identified by other diagnostic procedures in some cases. (author)

  16. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  17. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  18. Survey of computed tomography doses in head and chest protocols

    International Nuclear Information System (INIS)

    Souza, Giordana Salvi de; Silva, Ana Maria Marques da

    2016-01-01

    Computed tomography is a clinical tool for the diagnosis of patients. However, the patient is subjected to a complex dose distribution. The aim of this study was to survey dose indicators in head and chest protocols CT scans, in terms of Dose-Length Product(DLP) and effective dose for adult and pediatric patients, comparing them with diagnostic reference levels in the literature. Patients were divided into age groups and the following image acquisition parameters were collected: age, kV, mAs, Volumetric Computed Tomography Dose Index (CTDIvol) and DLP. The effective dose was found multiplying DLP by correction factors. The results were obtained from the third quartile and showed the importance of determining kV and mAs values for each patient depending on the studied region, age and thickness. (author)

  19. Comparison of the effects of TripleGates and Gates-Glidden burs on cervical dentin thickness and root canal area by using cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Kássio SOUSA

    2015-04-01

    Full Text Available The search for new instruments to promote an appropriate cervical preparation has led to the development of new rotary instruments such as TripleGates. However, to the best of the authors' knowledge, there is no study evaluating TripleGates effect on the “risk zone” of mandibular molars. Objectives : The aim of this study was to evaluate the effects of a crown-down sequence of Gates-Glidden and TripleGates burs on the remaining cervical dentin thickness and the total amount of dentin removed from the root canals during the instrumentation by using cone beam computed tomography. The number of separated instruments was also evaluated. Material and Methods : Mesial roots of 40 mandibular first molars were divided into 2 equal groups: crown-down sequence of Gates-Glidden (#3, #2, #1 and TripleGates burs. Cervical dentin thickness and canal area were measured before and after instrumentation by using cone beam computed tomography and image analysis software. Student’s t-test was used to determine significant differences at p0.05 were observed between the instruments, regarding the root canal area and dentin wall thickness. Conclusion : Both tested instruments used for cervical preparation were safe to be used in the mesial root canal of mandibular molars.

  20. Computed Tomography Technology: Development and Applications for Defence

    International Nuclear Information System (INIS)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-01-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT and E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  1. Intranasal dexmedetomidine for sedation for pediatric computed tomography imaging.

    Science.gov (United States)

    Mekitarian Filho, Eduardo; Robinson, Fay; de Carvalho, Werther Brunow; Gilio, Alfredo Elias; Mason, Keira P

    2015-05-01

    This prospective observational pilot study evaluated the aerosolized intranasal route for dexmedetomidine as a safe, effective, and efficient option for infant and pediatric sedation for computed tomography imaging. The mean time to sedation was 13.4 minutes, with excellent image quality, no failed sedations, or significant adverse events. Registered with ClinicalTrials.gov: NCT01900405. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Computed tomography on renal masses in dogs and cats

    International Nuclear Information System (INIS)

    Yamazoe, Kazuaki; Ohashi, Fumihito; Kadosawa, Tsuyoshi; Nishimura, Ryohei; Sasaki, Nobuo; Takeuchi, Akira.

    1994-01-01

    Computed tomography (CT) was performed on renal tumors (Wilms' tumor and renal cell carcinoma) and renal cysts in dogs and cats. CT images in renal tumors were well correlated with macroscopic findings, and contrast CT images were quite useful in differentiating tumoral regions from non-tumoral ones. On renal cysts, intravenous pyelography and ultrasonography were as effective as CT images in morphological diagnosis, but CT was considered to be superior for evaluating three-dimensional (3-D) relationships in complicated lesions. (author)

  3. Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler

    Directory of Open Access Journals (Sweden)

    A Saravanakumar

    2015-01-01

    Full Text Available In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP. Using these values, the weighted computed tomography dose index (CTDIw and in turn the volumetric CTDI (CTDIv were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB, India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.

  4. Performance of an extrapolation chamber in computed tomography standard beams

    International Nuclear Information System (INIS)

    Castro, Maysa C.; Silva, Natália F.; Caldas, Linda V.E.

    2017-01-01

    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI. (author)

  5. Performance of an extrapolation chamber in computed tomography standard beams

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Maysa C.; Silva, Natália F.; Caldas, Linda V.E., E-mail: mcastro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI. (author)

  6. Computed tomography findings in convergent strabismus fixus

    International Nuclear Information System (INIS)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio

    1995-01-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author)

  7. Computed tomography of the traumatized abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki [Wallace Memotial Baptist Hospital, Pusan (Korea, Republic of)

    1989-02-15

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries.

  8. Computed tomography of the traumatized abdomen

    International Nuclear Information System (INIS)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki

    1989-01-01

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries

  9. Multidetector Computed Tomography and Neuroendocrine Pancreaticoduodenal Tumors

    International Nuclear Information System (INIS)

    Rappeport, E.D.; Palnaes Hansen, C.; Kjaer, A.; Knigge, U.

    2006-01-01

    Purpose: To investigate the accuracy of dedicated pancreatic multidetector computed tomography (MDCT) in the diagnosis of neuroendocrine pancreaticoduodenal tumors (NPTs). Material and Methods: MDCT and other imaging studies in patients with suspected NPTs were identified. Thirty dedicated MDCT studies were done in 23 patients. Fourteen patients (16 operations) subsequently had surgery. Imaging reports were reviewed and findings compared with surgical findings and findings in other imaging studies. Results: Patients with surgery : 19 NPTs (16 extrapancreatic gastrinomas and 3 pancreatic NPTs) were identified at surgery. MDCT identified 16 and somatostatin receptor scintigraphy (SRS) 11 out of 19 tumors. Endoscopic ultrasound detected 11 out of 14 NPTs. Patients without surgery : In 4 out of 9 patients, no NPTs were identified at MDCT. Conclusion: Dedicated MDCT of the pancreas can identify many NPTs, including small duodenal and periduodenal tumors, and the detection rate is better than reported in the older literature on CT

  10. Quality control in quantitative computed tomography

    International Nuclear Information System (INIS)

    Jessen, K.A.; Joergensen, J.

    1989-01-01

    Computed tomography (CT) has for several years been an indispensable tool in diagnostic radiology, but it is only recently that extraction of quantitative information from CT images has been of practical clinical value. Only careful control of the scan parameters, and especially the scan geometry, allows useful information to be obtained; and it can be demonstrated by simple phantom measurements how sensitive a CT system can be to variations in size, shape and position of the phantom in the gantry aperture. Significant differences exist between systems that are not manifested in normal control of image quality and general performance tests. Therefore an actual system has to be analysed for its suitability for quantitative use of the images before critical clinical applications are justified. (author)

  11. The temporomandibular joint in computed tomography

    International Nuclear Information System (INIS)

    Pomaroli, A.; Lener, M.

    1988-01-01

    The first part describes details of the temporomandibular joint (TMJ) which are of interest for the examination by computed tomography. In the second part three new planes of reference for scanning of the ventral, middle or dorsal part of the joint are presented. CT examinations were made of 14 TMJ of corpses to identify the medial or ventral parts of the articular disc, medial wall of the articular capsule and medial or triangular recessus to achieve this were scanned the corpses with opened and closed mouth, as well as with closed sets of teeth using a sort of hypomochlion in the molar region to distract the TMJ. More over we applicated different contrast mediums like air and niob. (orig.) [de

  12. Neutron stimulated emission computed tomography: Background corrections

    International Nuclear Information System (INIS)

    Floyd, Carey E.; Sharma, Amy C.; Bender, Janelle E.; Kapadia, Anuj J.; Xia, Jessie Q.; Harrawood, Brian P.; Tourassi, Georgia D.; Lo, Joseph Y.; Kiser, Matthew R.; Crowell, Alexander S.; Pedroni, Ronald S.; Macri, Robert A.; Tajima, Shigeyuki; Howell, Calvin R.

    2007-01-01

    Neutron stimulated emission computed tomography (NSECT) is an imaging technique that provides an in-vivo tomographic spectroscopic image of the distribution of elements in a body. To achieve this, a neutron beam illuminates the body. Nuclei in the body along the path of the beam are stimulated by inelastic scattering of the neutrons in the beam and emit characteristic gamma photons whose unique energy identifies the element. The emitted gammas are collected in a spectrometer and form a projection intensity for each spectral line at the projection orientation of the neutron beam. Rotating and translating either the body or the beam will allow a tomographic projection set to be acquired. Images are reconstructed to represent the spatial distribution of elements in the body. Critical to this process is the appropriate removal of background gamma events from the spectrum. Here we demonstrate the equivalence of two background correction techniques and discuss the appropriate application of each

  13. Computed tomography study of otitis media

    International Nuclear Information System (INIS)

    Bahia, Paulo Roberto Valle; Marchiori, Edson

    1997-01-01

    The findings of computed tomography (CT) of 89 patients clinically suspected of having otitis media were studied in this work. Such results were compared to clinical diagnosis, otoscopy, surgical findings and previous data. Among the results of our analysis, we studied seven patients with acute otitis media and 83 patients with chronic otitis media. The patients with acute otitis media have undergone CT examinations to evaluate possible spread to central nervous system. The diagnosis of cholesteatoma, its extension and complications were the main indication. for chronic otitis media study. The main findings of the cholesteatomatous otitis were the occupation of the epitympanun, the bony wall destruction and the ossicular chain erosion. The CT demonstrated a great sensibility to diagnose the cholesteatoma. (author)

  14. Diagnosis of cerebral disorders using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, K [Tokyo Women' s Medical Coll. (Japan)

    1980-01-01

    Computed tomography (CT), which makes differential diagnosis of cerebral disorders possible, was applied in the diagnosis of hypertensive intracerebral hemorrhage, cerebral thrombosis, subarachnoid hemorrhage, and cerebrovascular Moyamoya disease. CT findings of hypertensive intracerebral hemorrhage showed the localization, volume, and direction of hematoma, and the classification of hematoma according to CT findings was highly correlated to the clinical symptoms of the patients. CT findings of cerebral thrombosis showed the extension of the lesion to be a low density area, but there were many cases in which they did not show a low density area immediately after an attack. CT findings of subarachnoid hemorrhage were very useful in the diagnosis of intracerebral hematoma, ventricular hematoma, and intracranial hematoma secondary to this disease. However, it was very difficult to diagnose cerebrovascular Moyamoya disease by means of CT.

  15. Diagnosis of cerebral disorders using computed tomography

    International Nuclear Information System (INIS)

    Kitamura, Koichi

    1980-01-01

    Computed tomography (CT), which makes differential diagnosis of cerebral disorders possible, was applied in the diagnosis of hypertensive intracerebral hemorrhage, cerebral thrombosis, subarachnoid hemorrhage, and cerebrovascular Moyamoya disease. CT findings of hypertensive intracerebral hemorrhage showed the localization, volume, and direction of hematoma, and the classification of hematoma according to CT findings was highly correlated to the clinical symptoms of the patients. CT findings of cerebral thrombosis showed the extension of the lesion to be a low density area, but there were many cases in which they did not show a low density area immediately after an attack. CT findings of subarachnoid hemorrhage were very useful in the diagnosis of intracerebral hematoma, ventricular hematoma, and intracranial hematoma secondary to this disease. However, it was very difficult to diagnose cerebrovascular Moyamoya disease by means of CT. (Nishio, M.)

  16. The dynamic micro computed tomography at SSRF

    Science.gov (United States)

    Chen, R.; Xu, L.; Du, G.; Deng, B.; Xie, H.; Xiao, T.

    2018-05-01

    Synchrotron radiation micro-computed tomography (SR-μCT) is a critical technique for quantitative characterizing the 3D internal structure of samples, recently the dynamic SR-μCT has been attracting vast attention since it can evaluate the three-dimensional structure evolution of a sample. A dynamic μCT method, which is based on monochromatic beam, was developed at the X-ray Imaging and Biomedical Application Beamline at Shanghai Synchrotron Radiation Facility, by combining the compressed sensing based CT reconstruction algorithm and hardware upgrade. The monochromatic beam based method can achieve quantitative information, and lower dose than the white beam base method in which the lower energy beam is absorbed by the sample rather than contribute to the final imaging signal. The developed method is successfully used to investigate the compression of the air sac during respiration in a bell cricket, providing new knowledge for further research on the insect respiratory system.

  17. Computed tomography of the pituitary gland

    International Nuclear Information System (INIS)

    Bonneville, J.F.; Cattin, F.; Dietemann, J.L.

    1986-01-01

    This book is written entirely to include the imaging of the pituitary gland by computed tomography (CT). The first three chapters illustrated technical aspects of scanning, anatomic depiction of the gland by CT, and the use of dynamic CT scanning for detecting and displaying abnormalities. The chapters discuss and illustrate various types of pathologic processes in and around the pituitary gland. One short but very helpful chapter demonstrates potential pitfalls due to the combination of anatomic variants and the geometry of CT sections. Some illustrations of disease processed are depicted by magnetic resonance imaging. All major types of pituitary diseases are illustrated. Lists of readily available English-language references are available. A small subject index is provided at the end of the book in which the illustrations are identified by use of a special numeric front

  18. Ward nurses' knowledge of computed tomography scanning.

    Science.gov (United States)

    Majeed, M A; Nayeemuddin, M; Christie, M

    Patients benefit from and are reassured by advance information on procedures that they are to undergo. Ward nurses should have adequate knowledge of radiological investigations to ensure proper patient preparation and good interdepartmental communication to avoid delays and cancellations. This study was conducted to assess the ward nurses' knowledge of the process of computed tomography (CT) scanning. One hundred and twenty qualified nurses were asked to complete a questionnaire regarding CT scanning. The findings revealed a suboptimal level of awareness about the process. This is probably due to lack of formal teaching for nurses on the wards in regards the different radiological procedures and patient preparation. There is a strong case for better educational talks on rapidly changing radiological techniques for ward staff to ensure high-quality patient care.

  19. Computed tomography study of Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Arai, H; Kobayashi, K; Ikeda, Y; Nagao, Y; Ogihara, R; Kosaka, K

    1983-01-01

    Computed tomography (CT) was used to study cerebral atrophy in 18 patients with clinically diagnosed Alzheimer's disease of presenile type and in 14 healthy age-matched subjects as controls. Using the computerized planimetric method, Subarachnoid Space Volume Index and Ventricle Volume Index were calculated as the measure of cortical atrophy and ventricular dilatation respectively. From the results the following conclusions were drawn: 1. The cerebral atrophy in Alzheimer patients could be attributable to the disease processes rather than to physiological aging of the brain. 2. The degree of atrophy increases in parallel with the progress of the clinical stage, and the cortical atrophy is already apparent at an early stage, whereas the ventricular dilatation becomes pronounced at later stages. 3. CT could be one of the most useful clinical tests available for the diagnosis of Alzheimer's disease.

  20. Practical techniques for pediatric computed tomography

    International Nuclear Information System (INIS)

    Fitz, C.R.; Harwood-Nash, D.C.; Kirks, D.R.; Kaufman, R.A.; Berger, P.E.; Kuhn, J.P.; Siegel, M.J.

    1983-01-01

    Dr. Donald Kirks has assembled this section on Practical Techniques for Pediatric Computed Tomography. The material is based on a presentation in the Special Interest session at the 25th Annual Meeting of the Society for Pediatric Radiology in New Orleans, Louisiana, USA in 1982. Meticulous attention to detail and technique is required to ensure an optimal CT examination. CT techniques specifically applicable to infants and children have not been disseminated in the radiology literature and in this respect it may rightly be observed that ''the child is not a small adult''. What follows is a ''cookbook'' prepared by seven participants and it is printed in Pediatric Radiology, in outline form, as a statement of individual preferences for pediatric CT techniques. This outline gives concise explanation of techniques and permits prompt dissemination of information. (orig.)

  1. Teleradiology for emergency cranial computed tomography

    International Nuclear Information System (INIS)

    Stranzinger, E.; Treumann, T.C.; Dreier, D.; Allgayer, B.

    2003-01-01

    Purpose: We report our experience with the teleradiologic service provided by a center hospital (CH) for emergency cranial computed tomography (CCT) in two regional hospitals (RH) during a 12-month period. The clinical and economic impact of teleradiology will be discussed as well as the acceptance by the clinicians of the regional hospitals. Material and Methods: In 2001, 213 CT-scans in 202 patients were performed and reported using teleradiology. Teleradiologic and final medical diagnosis were analysed by the medical reports. The transferral of the patients to a CH and their further treatment were checked. The referring physicians in the RH were questionnaired about the teleradiological support. Results: 18 (9%) patients had to be urgently transferred to a CH based on the CT findings in the teleradiological reports. 24 patients (11%) were transferred to a center hospital during further treatment. 80% of patients were treated in the RH. (orig.) [de

  2. Quality assurance of computed tomography (CT) scanners

    International Nuclear Information System (INIS)

    Sankaran, A.; Sanu, K.K. . Email : a_sankaran@vsnl.com

    2004-01-01

    This article reviews the present status of research work and development of various test objects, phantoms and detector/instrumentation systems for quality assurance (QA) of computed tomography (CT) scanners, carried out in advanced countries, with emphasis on similar work done in this research centre. CT scanner is a complex equipment and routine quality control procedures are essential to the maintenance of image quality with optimum patient dose. Image quality can be ensured only through correlation between prospective monitoring of system components and tests of overall performance with standard phantoms. CT examinations contribute a large share to the population dose in advanced countries. The unique dosimetry problems in CT necessitate special techniques. This article describes a comprehensive kit developed indigenously for the following QA and type approval tests as well as for research studies on image quality/dosimetry on CT scanners

  3. Minimising medically unwarranted computed tomography scans

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    As computed tomography (CT) is such a superb diagnostic tool and individual CT risks are small, whenever a CT scan is clinically warranted, the CT benefit/risk balance is by far in the patient’s favour. However, if a CT scan is not clinically warranted, this balance shifts dramatically. It is likely that at least 25% of CT scans fall into this latter category, in that they could either be replaced with alternative imaging modalities or could be avoided entirely. Use of clinical decision rules for CT usage represents a powerful approach for slowing down the increase in CT usage, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they may not be clinically helpful.

  4. System Matrix Analysis for Computed Tomography Imaging

    Science.gov (United States)

    Flores, Liubov; Vidal, Vicent; Verdú, Gumersindo

    2015-01-01

    In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data. PMID:26575482

  5. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  6. Data processing device for computed tomography system

    International Nuclear Information System (INIS)

    Nakayama, N.; Ito, Y.; Iwata, K.; Nishihara, E.; Shibayama, S.

    1984-01-01

    A data processing device applied to a computed tomography system which examines a living body utilizing radiation of X-rays is disclosed. The X-rays which have penetrated the living body are converted into electric signals in a detecting section. The electric signals are acquired and converted from an analog form into a digital form in a data acquisition section, and then supplied to a matrix data-generating section included in the data processing device. By this matrix data-generating section are generated matrix data which correspond to a plurality of projection data. These matrix data are supplied to a partial sum-producing section. The partial sums respectively corresponding to groups of the matrix data are calculated in this partial sum-producing section and then supplied to an accumulation section. In this accumulation section, the final value corresponding to the total sum of the matrix data is calculated, whereby the calculation for image reconstruction is performed

  7. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  8. Computer tomography of intracranial tumours and hematomas

    International Nuclear Information System (INIS)

    Tans, J.T.J.

    1978-01-01

    The value of computed tomography (CT) for the diagnosis of intracranial tumors and hematomas was investigated in a retrospective study comprising 220 patients. All C.T.scans are reviewed and described in detail. To assess the diagnostic accuracy, the original interpretation of the C.T.scans was compared with that of conventional neuroradiological and neurophysiological examinations. The aspect on C.T. of the various types of tumors and hematomas proved to vary widely and specific features were seldom seen. This holds particularly for the malignant tumors. Benign tumors such as meningeomas, adenomas and neurilemmomas showed a rather easily identifiable and almost identical picture of the C.T.scan, and diagnosis had to be based mainly on differences in localization. The hematomas, with the exception of the older intracerebral ones, showed the most characteristic C.T.abnormalities. (Auth.)

  9. Computed tomography of the abnormal thymus

    International Nuclear Information System (INIS)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion

  10. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  11. Computed tomography of Rathke's cleft cyst

    International Nuclear Information System (INIS)

    Shiokawa, Yoshiaki; Teramoto, Akira; Mayanagi, Yoshiaki; Hanamura, Tetsu; Noguchi, Makoto; Takakura, Kintomo.

    1986-01-01

    The computed tomography (CT) findings in six cases of Rathke's cleft cyst (RCC) were presented. According to the location of the RCC, we divided these cases into two types - the suprasellar type and the intrasellar type. The characteristic CT findings are as follows: SUPRASELLAR type 1. smooth, round mass, 2. various densities, 3. no enhancement, INTRASELLAR type 1. low-density area in the posterior sella turcica, 2. no enhancement, 3. suprasellar high-density mass; enhanced pituitary gland pushed up by the intrasellar RCC. As RCC are more common than was formerly suspected, this disease should always be considered in the differential diagnosis of a patient showing a non-enhancing, non-calcified sellar/suprasellar cyst on CT scans. (author)

  12. Computed tomography of Rathke's cleft cyst

    Energy Technology Data Exchange (ETDEWEB)

    Shiokawa, Yoshiaki; Teramoto, Akira; Mayanagi, Yoshiaki; Hanamura, Tetsu; Noguchi, Makoto; Takakura, Kintomo

    1986-02-01

    The computed tomography (CT) findings in six cases of Rathke's cleft cyst (RCC) were presented. According to the location of the RCC, we divided these cases into two types - the suprasellar type and the intrasellar type. The characteristic CT findings are as follows: SUPRASELLAR type 1. smooth, round mass, 2. various densities, 3. no enhancement, INTRASELLAR type 1. low-density area in the posterior sella turcica, 2. no enhancement, 3. suprasellar high-density mass; enhanced pituitary gland pushed up by the intrasellar RCC. As RCC are more common than was formerly suspected, this disease should always be considered in the differential diagnosis of a patient showing a non-enhancing, non-calcified sellar/suprasellar cyst on CT scans.

  13. A computed tomography study of Alzheimer's disease

    International Nuclear Information System (INIS)

    Arai, H.; Kobayashi, K.; Juntendo Univ. School of Medicine, Tokyo; Ikeda, Y.; Nagao, Y.; Ogihara, R.; Kosaka, K.; Psychiatric Research Inst. of Tokyo

    1983-01-01

    Computed tomography (CT) was used to study cerebral atrophy in 18 patients with clinically diagnosed Alzheimer's disease of presenile type and in 14 healthy age-matched subjects as controls. Using the computerized planimetric method, Subarachnoid Space Volume Index and Ventricle Volume Index were calculated as the measure of cortical atrophy and ventricular dilatation respectively. From the results the following conclusions were drawn: 1. The cerebral atrophy in Alzheimer patients could be attributable to the disease processes rather than to physiological aging of the brain. 2. The degree of atrophy increases in parallel with the progress of the clinical stage, and the cortical atrophy is already apparent at an early stage, whereas the ventricular dilatation becomes pronounced at later stages. 3. CT could be one of the most useful clinical tests available for the diagnosis of Alzheimer's disease. (orig.) [de

  14. Computed Tomography findings in Fournier's gangrene

    International Nuclear Information System (INIS)

    Isusi, M.; Campo, M.; Oleaga, L.; Grande, J.; Grande, D.

    2000-01-01

    To assess the utility of computed tomography (CT) as an imaging technique in the diagnosis and determination of the extension of Fournier's gangrene (FG). We report the cases of six patients who had been clinically diagnosed as having FG, CT, enhanced by oral and intravenous contrast media, was performed in all the patients. All six patients presented soft tissue masses and gas in the scrotal region, which were also detected in the perineal region in five. In two patients, the gas extended toward anterior abdominal wall and in one of them, it also observed in anterior and posterior para renal space. The major predisposing factors were diabetes and alcoholism and the most common triggering factor was urologic disease. CT confirms the existence of FG and aids in assessing its extension and, in some cases, in identifying the underlying cause. (Author) 15 refs

  15. Minamata disease demonstrated by computed tomography

    International Nuclear Information System (INIS)

    Matsumoto, S.C.; Okajima, T.; Inayoshi, S.; Ueno, H.

    1988-01-01

    Computed tomography was studied in the patients with Minamata disease, a methylmercury poisoning caused by the ingestion of contaminated sea foods. The characteristic changes in the acquired cases were atrophy of the visual calcarine cortex and of the cerebellar vermis and or hemisphere. Marked atrophy of the calcarine cortex produced the sac-shaped low density areas between the occipital lobes and diffuse and marked cerebellar atrophy with enlargement of the fourth ventricle and cisterns of the posterior fossa produced a shrunken image on CT. Morphometric analysis confirmed these findings. In the fetal cases, the changes on CT were slight and no definite atrophy was demonstrated in either the calcarine cortex or the cerebellum. Morphometric analysis disclosed an increase of size of the middle portions of the lateral ventricle and the third and fourth ventricles. (orig.)

  16. Computed tomography of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Megibow, A.J.; Balthazar, E.J.

    1986-01-01

    New generation CT scans combined with high-detail barium studies have now allowed radiologists to see and gain a more complete understanding of the wall and surrounding structures of the gastrointestinal tract. The editors state that their intent is to ''present in a comprehensive volume an up-to-date evaluation o the role, significance, indications, and limitations of computed tomography of the gastrointestinal tract.'' There is an initial chapter on CT scanning techniques and the use of oral contrast agents. Chapters follow on Ct of the esophagus, stomach, duodenum, small bowel, and colon. The chapters start with a description of the anatomic structures and then cover in detail common pathologic conditions that affect the organ. Indications for examinations are also included in many chapters. There are final chapters on percutaneous drainage of abscesses and fluid collections and on radiologic-patholoic correlation of some of the more common entities

  17. Computed tomography findings of malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka (Kure Kyosai Hospital, Hiroshima (Japan))

    1994-04-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author).

  18. Computed tomography findings of malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka

    1994-01-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author)

  19. Computed tomography angiogram. Accuracy in renal surgery

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Al-Hathal, Naif; Al-Fuhaid, Turki; Raza, Sayed; Al-Yami, Fahad; Al-Taweel, Waleed; Alomar, Mohamed; Al-Nagshabandi, Nizar

    2009-01-01

    The objective of this study was to determine the sensitivity and specificity of computed tomography angiogram (CTA) in detecting number and location of renal arteries and veins as well as crossing vessels causing uretero-pelvic junction obstruction (UPJO), and to determine if this can be used in decision-making algorithms for treatment of UPJO. A prospective study was carried out in patients undergoing open, laparoscopic and robotic renal surgery from April 2005 until October 2006. All patients were imaged using CTA with 1.25 collimation of arterial and venous phases. Each multi-detector CTA was then read by one radiologist and his results were compared prospectively with the actual intra-operative findings. Overall, 118 patients were included. CTA had 93% sensitivity, 77% specificity and 90% overall accuracy for detecting a single renal artery, and 76% sensitivity, 92% specificity and 90% overall accuracy for detecting two or more renal arteries (Pearson χ 2 =0.001). There was 95% sensitivity, 84% specificity and 85% overall accuracy for detecting the number of renal veins. CTA had 100% overall accuracy in detecting early dividing renal artery (defined as less than 1.5 cm branching from origin), and 83.3% sensitivity, specificity and overall accuracy in detecting crossing vessels at UPJ. The percentage of surgeons stating CTA to be helpful as pre-operative diagnostic tool was 85%. Computed tomography angiogram is simple, quick and can provide an accurate pre-operative renal vascular anatomy in terms of number and location of renal vessels, early dividing renal arteries and crossing vessels at UPJ. (author)

  20. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)