  1. GPU-based cone beam computed tomography.

    Science.gov (United States)

    Noël, Peter B; Walczak, Alan M; Xu, Jinhui; Corso, Jason J; Hoffmann, Kenneth R; Schafer, Sebastian

    2010-06-01

    The use of cone beam computed tomography (CBCT) is growing in the clinical arena due to its ability to provide 3D information during interventions, its high diagnostic quality (sub-millimeter resolution), and its short scanning times (60 s). In many situations, the short scanning time of CBCT is followed by a time-consuming 3D reconstruction. The standard reconstruction algorithm for CBCT data is the filtered backprojection, which for a volume of size 256(3) takes up to 25 min on a standard system. Recent developments in the area of Graphic Processing Units (GPUs) make it possible to have access to high-performance computing solutions at a low cost, allowing their use in many scientific problems. We have implemented an algorithm for 3D reconstruction of CBCT data using the Compute Unified Device Architecture (CUDA) provided by NVIDIA (NVIDIA Corporation, Santa Clara, California), which was executed on a NVIDIA GeForce GTX 280. Our implementation results in improved reconstruction times from minutes, and perhaps hours, to a matter of seconds, while also giving the clinician the ability to view 3D volumetric data at higher resolutions. We evaluated our implementation on ten clinical data sets and one phantom data set to observe if differences occur between CPU and GPU-based reconstructions. By using our approach, the computation time for 256(3) is reduced from 25 min on the CPU to 3.2 s on the GPU. The GPU reconstruction time for 512(3) volumes is 8.5 s. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  2. Total variation-based neutron computed tomography

    Science.gov (United States)

    Barnard, Richard C.; Bilheux, Hassina; Toops, Todd; Nafziger, Eric; Finney, Charles; Splitter, Derek; Archibald, Rick

    2018-05-01

    We perform the neutron computed tomography reconstruction problem via an inverse problem formulation with a total variation penalty. In the case of highly under-resolved angular measurements, the total variation penalty suppresses high-frequency artifacts which appear in filtered back projections. In order to efficiently compute solutions for this problem, we implement a variation of the split Bregman algorithm; due to the error-forgetting nature of the algorithm, the computational cost of updating can be significantly reduced via very inexact approximate linear solvers. We present the effectiveness of the algorithm in the significantly low-angular sampling case using synthetic test problems as well as data obtained from a high flux neutron source. The algorithm removes artifacts and can even roughly capture small features when an extremely low number of angles are used.

  3. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  4. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  5. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  7. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  8. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  9. Computed tomography scan based prediction of the vulnerable carotid plaque

    DEFF Research Database (Denmark)

    Diab, Hadi Mahmoud Haider; Rasmussen, Lars Melholt; Duvnjak, Stevo

    2017-01-01

    BACKGROUND: Primary to validate a commercial semi-automated computed tomography angiography (CTA) -software for vulnerable plaque detection compared to histology of carotid endarterectomy (CEA) specimens and secondary validating calcifications scores by in vivo CTA with ex vivo non......-contrast enhanced computed tomography (NCCT). METHODS: From January 2014 to October 2016 53 patients were included retrospectively, using a cross-sectional design. All patients underwent both CTA and CEA. Sixteen patients had their CEA specimen NCCT scanned. The semi-automated CTA software analyzed carotid stenosis...

  10. Cyst-based measurements for assessing lymphangioleiomyomatosis in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lo, P., E-mail: pechinlo@mednet.edu.ucla; Brown, M. S.; Kim, H.; Kim, H.; Goldin, J. G. [Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California 90024 (United States); Argula, R.; Strange, C. [Division of Pulmonary and Critical Care Medicine, Medical University of South Carolina, Charleston, South Carolina 29425 (United States)

    2015-05-15

    Purpose: To investigate the efficacy of a new family of measurements made on individual pulmonary cysts extracted from computed tomography (CT) for assessing the severity of lymphangioleiomyomatosis (LAM). Methods: CT images were analyzed using thresholding to identify a cystic region of interest from chest CT of LAM patients. Individual cysts were then extracted from the cystic region by the watershed algorithm, which separates individual cysts based on subtle edges within the cystic regions. A family of measurements were then computed, which quantify the amount, distribution, and boundary appearance of the cysts. Sequential floating feature selection was used to select a small subset of features for quantification of the severity of LAM. Adjusted R{sup 2} from multiple linear regression and R{sup 2} from linear regression against measurements from spirometry were used to compare the performance of our proposed measurements with currently used density based CT measurements in the literature, namely, the relative area measure and the D measure. Results: Volumetric CT data, performed at total lung capacity and residual volume, from a total of 49 subjects enrolled in the MILES trial were used in our study. Our proposed measures had adjusted R{sup 2} ranging from 0.42 to 0.59 when regressing against the spirometry measures, with p < 0.05. For previously used density based CT measurements in the literature, the best R{sup 2} was 0.46 (for only one instance), with the majority being lower than 0.3 or p > 0.05. Conclusions: The proposed family of CT-based cyst measurements have better correlation with spirometric measures than previously used density based CT measurements. They show potential as a sensitive tool for quantitatively assessing the severity of LAM.

  11. Simulation-based artifact correction (SBAC) for metrological computed tomography

    Science.gov (United States)

    Maier, Joscha; Leinweber, Carsten; Sawall, Stefan; Stoschus, Henning; Ballach, Frederic; Müller, Tobias; Hammer, Michael; Christoph, Ralf; Kachelrieß, Marc

    2017-06-01

    Computed tomography (CT) is a valuable tool for the metrolocical assessment of industrial components. However, the application of CT to the investigation of highly attenuating objects or multi-material components is often restricted by the presence of CT artifacts caused by beam hardening, x-ray scatter, off-focal radiation, partial volume effects or the cone-beam reconstruction itself. In order to overcome this limitation, this paper proposes an approach to calculate a correction term that compensates for the contribution of artifacts and thus enables an appropriate assessment of these components using CT. Therefore, we make use of computer simulations of the CT measurement process. Based on an appropriate model of the object, e.g. an initial reconstruction or a CAD model, two simulations are carried out. One simulation considers all physical effects that cause artifacts using dedicated analytic methods as well as Monte Carlo-based models. The other one represents an ideal CT measurement i.e. a measurement in parallel beam geometry with a monochromatic, point-like x-ray source and no x-ray scattering. Thus, the difference between these simulations is an estimate for the present artifacts and can be used to correct the acquired projection data or the corresponding CT reconstruction, respectively. The performance of the proposed approach is evaluated using simulated as well as measured data of single and multi-material components. Our approach yields CT reconstructions that are nearly free of artifacts and thereby clearly outperforms commonly used artifact reduction algorithms in terms of image quality. A comparison against tactile reference measurements demonstrates the ability of the proposed approach to increase the accuracy of the metrological assessment significantly.

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  13. The transesophageal echocardiography simulator based on computed tomography images.

    Science.gov (United States)

    Piórkowski, Adam; Kempny, Aleksander

    2013-02-01

    Simulators are a new tool in education in many fields, including medicine, where they greatly improve familiarity with medical procedures, reduce costs, and, importantly, cause no harm to patients. This is so in the case of transesophageal echocardiography (TEE), in which the use of a simulator facilitates spatial orientation and helps in case studies. The aim of the project described in this paper is to simulate an examination by TEE. This research makes use of available computed tomography data to simulate the corresponding echocardiographic view. This paper describes the essential characteristics that distinguish these two modalities and the key principles of the wave phenomena that should be considered in the simulation process, taking into account the conditions specific to the echocardiography. The construction of the CT2TEE (Web-based TEE simulator) is also presented. The considerations include ray-tracing and ray-casting techniques in the context of ultrasound beam and artifact simulation. An important aspect of the interaction with the user is raised.

  14. Prior-based artifact correction (PBAC) in computed tomography

    International Nuclear Information System (INIS)

    Heußer, Thorsten; Brehm, Marcus; Ritschl, Ludwig; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. Methods: The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. Results: The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. Conclusions: The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data

  15. Computed tomography vs. digital radiography assessment for detection of osteolysis in asymptomatic patients with uncemented cups: a proposal for a new classification system based on computer tomography.

    Science.gov (United States)

    Sandgren, Buster; Crafoord, Joakim; Garellick, Göran; Carlsson, Lars; Weidenhielm, Lars; Olivecrona, Henrik

    2013-10-01

    Digital radiographic images in the anterior-posterior and lateral view have been gold standard for evaluation of peri-acetabular osteolysis for patients with an uncemented hip replacement. We compared digital radiographic images and computer tomography in detection of peri-acetabular osteolysis and devised a classification system based on computer tomography. Digital radiographs were compared with computer tomography on 206 hips, with a mean follow up 10 years after surgery. The patients had no clinical signs of osteolysis and none were planned for revision surgery. On digital radiographs, 192 cases had no osteolysis and only 14 cases had osteolysis. When using computer tomography there were 184 cases showing small or large osteolysis and only 22 patients had no osteolysis. A classification system for peri-acetabular osteolysis is proposed based on computer tomography that is easy to use on standard follow up evaluation. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. X-Ray Computed Tomography of Tranquility Base Moon Rock

    Science.gov (United States)

    Jones, Justin S.; Garvin, Jim; Viens, Mike; Kent, Ryan; Munoz, Bruno

    2016-01-01

    X-ray Computed Tomography (CT) was used for the first time on the Apollo 11 Lunar Sample number 10057.30, which had been previously maintained by the White House, then transferred back to NASA under the care of Goddard Space Flight Center. Results from this analysis show detailed images of the internal structure of the moon rock, including vesicles (pores), crystal needles, and crystal bundles. These crystals, possibly the common mineral ilmenite, are found in abundance and with random orientation. Future work, in particular a greater understanding of these crystals and their formation, may lead to a more in-depth understanding of the lunar surface evolution and mineral content.

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  18. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

    Science.gov (United States)

    Kinahan, Paul E; Hasegawa, Bruce H; Beyer, Thomas

    2003-07-01

    A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. Copyright 2003 Elsevier Inc. All rights reserved.

  19. Computed tomography

    International Nuclear Information System (INIS)

    Boyd, D.P.

    1989-01-01

    This paper reports on computed tomographic (CT) scanning which has improved computer-assisted imaging modalities for radiologic diagnosis. The advantage of this modality is its ability to image thin cross-sectional planes of the body, thus uncovering density information in three dimensions without tissue superposition problems. Because this enables vastly superior imaging of soft tissues in the brain and body, CT scanning was immediately successful and continues to grow in importance as improvements are made in speed, resolution, and cost efficiency. CT scanners are used for general purposes, and the more advanced machines are generally preferred in large hospitals, where volume and variety of usage justifies the cost. For imaging in the abdomen, a scanner with a rapid speed is preferred because peristalsis, involuntary motion of the diaphram, and even cardiac motion are present and can significantly degrade image quality. When contrast media is used in imaging to demonstrate scanner, immediate review of images, and multiformat hardcopy production. A second console is reserved for the radiologist to read images and perform the several types of image analysis that are available. Since CT images contain quantitative information in terms of density values and contours of organs, quantitation of volumes, areas, and masses is possible. This is accomplished with region-of- interest methods, which involve the electronic outlining of the selected region of the television display monitor with a trackball-controlled cursor. In addition, various image- processing options, such as edge enhancement (for viewing fine details of edges) or smoothing filters (for enhancing the detectability of low-contrast lesions) are useful tools

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  1. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  4. Simulation of computed tomography dose based on voxel phantom

    Science.gov (United States)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  5. Computer-based quantitative computed tomography image analysis in idiopathic pulmonary fibrosis: A mini review.

    Science.gov (United States)

    Ohkubo, Hirotsugu; Nakagawa, Hiroaki; Niimi, Akio

    2018-01-01

    Idiopathic pulmonary fibrosis (IPF) is the most common type of progressive idiopathic interstitial pneumonia in adults. Many computer-based image analysis methods of chest computed tomography (CT) used in patients with IPF include the mean CT value of the whole lungs, density histogram analysis, density mask technique, and texture classification methods. Most of these methods offer good assessment of pulmonary functions, disease progression, and mortality. Each method has merits that can be used in clinical practice. One of the texture classification methods is reported to be superior to visual CT scoring by radiologist for correlation with pulmonary function and prediction of mortality. In this mini review, we summarize the current literature on computer-based CT image analysis of IPF and discuss its limitations and several future directions. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  6. Computed tomography-based subclassification of chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Dirksen, Asger; Wille, Mathilde M W

    2016-01-01

    Computed tomography (CT) is an obvious modality for subclassification of COPD. Traditionally, the pulmonary involvement of chronic obstructive pulmonary disease (COPD) in smokers is understood as a combination of deleterious effects of smoking on small airways (chronic bronchitis and small airways...... observed in COPD are subtle. Furthermore, recent results indicate that emphysema may also be the essential pathophysiologic mechanism behind the airflow limitation of COPD. The definition of COPD excludes bronchiectasis as a symptomatic subtype of COPD, and CT findings in chronic bronchitis...... and exacerbations of COPD are rather unspecific. This leaves emphysema as the most obvious candidate for subclassification of COPD. Both chest radiologists and pulmonary physicians are quite familiar with the appearance of various patterns of emphysema on HRCT, such as centrilobular, panlobular, and paraseptal...

  7. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  8. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  10. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  11. Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

    Science.gov (United States)

    Karki, Kishor; Saraiya, Siddharth; Hugo, Geoffrey D; Mukhopadhyay, Nitai; Jan, Nuzhat; Schuster, Jessica; Schutzer, Matthew; Fahrner, Lester; Groves, Robert; Olsen, Kathryn M; Ford, John C; Weiss, Elisabeth

    2017-09-01

    To investigate interobserver delineation variability for gross tumor volumes of primary lung tumors and associated pathologic lymph nodes using magnetic resonance imaging (MRI), and to compare the results with computed tomography (CT) alone- and positron emission tomography (PET)-CT-based delineations. Seven physicians delineated the tumor volumes of 10 patients for the following scenarios: (1) CT only, (2) PET-CT fusion images registered to CT ("clinical standard"), and (3) postcontrast T1-weighted MRI registered with diffusion-weighted MRI. To compute interobserver variability, the median surface was generated from all observers' contours and used as the reference surface. A physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest wall) on the median surface. Contoured volumes and bidirectional local distances between individual observers' contours and the reference contour were analyzed. Computed tomography- and MRI-based tumor volumes normalized relative to PET-CT-based volumes were 1.62 ± 0.76 (mean ± standard deviation) and 1.38 ± 0.44, respectively. Volume differences between the imaging modalities were not significant. Between observers, the mean normalized volumes per patient averaged over all patients varied significantly by a factor of 1.6 (MRI) and 2.0 (CT and PET-CT) (P=4.10 × 10 -5 to 3.82 × 10 -9 ). The tumor-atelectasis interface had a significantly higher variability than other interfaces for all modalities combined (P=.0006). The interfaces with the smallest uncertainties were tumor-lung (on CT) and tumor-mediastinum (on PET-CT and MRI). Although MRI-based contouring showed overall larger variability than PET-CT, contouring variability depended on the interface type and was not significantly different between modalities, despite the limited observer experience with MRI. Multimodality imaging and combining different imaging characteristics might be the best approach to define

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  14. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  4. Simulation-Based Planning of Optimal Conditions for Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Reisinger, S.; Kasperl, S.; Franz, M.

    2011-01-01

    We present a method to optimise conditions for industrial computed tomography (CT). This optimisation is based on a deterministic simulation. Our algorithm finds task-specific CT equipment settings to achieve optimal exposure parameters by means of an STL-model of the specimen and a raytracing...

  5. Registration-based Reconstruction of Four-dimensional Cone Beam Computed Tomography

    DEFF Research Database (Denmark)

    Christoffersen, Christian; Hansen, David Christoffer; Poulsen, Per Rugaard

    2013-01-01

    We present a new method for reconstruction of four-dimensional (4D) cone beam computed tomography from an undersampled set of X-ray projections. The novelty of the proposed method lies in utilizing optical flow based registration to facilitate that each temporal phase is reconstructed from the full...

  6. [Treatment choice in dacryostenosis based on single-photon emission computed tomography and X-ray computed tomography findings].

    Science.gov (United States)

    At'kova, E L; Yartsev, V D; Tomashevskiy, I O; Krakhovetskiy, N N

    2016-01-01

    To develop surgical indications in dacryostenosis within the vertical portion of lacrimal pathways that would consider findings of single-photon emission computed tomography (SPECT) combined with X-ray computed tomography (CT). A total of 96 patients with isolated vertical-portion dacryostenosis (127 cases) were enrolled. The examination included collecting Munk's scores for epiphora, optical coherence tomography of the lower tear meniscus, lacrimal scintigraphy, and SPECT/CT. Group 1 (40 cases) was composed of patients with lacrimal obstruction on CT, group 2 (87 cases) - of those whose lacrimal pathways proved passable. There were also 3 patients (4 cases) from group 1, whose lacrimal pathways, despite being blocked on CT, were still passable on SPECT. Surgeries performed in group 1 were endoscopic endonasal dacryocystorhinostomy (DCR) (36 cases) and pathways recanalization with bicanalicular intubation and balloon dacryoplasty (DCP) (4 cases). In group 2, all patients (87 cases) underwent recanalization with bicanalicular intubation (supplemented with balloon DCP in 32 cases). Surgical results were evaluated 8-12 months after the treatment. In group 2, particular attention was paid to the concordance in locations of dacryostenosis provided by CT and SPECT scans. Favorable outcomes of endoscopic endonasal DCR were obtained in as many as 32 cases from group 1 (88.9%), while in 4 cases (12.1%) the condition relapsed. Of those patients whose stenosis was not complete on SPECT, 3 cases (75.0%) improved, 1 (25.0%) - relapsed. In group 2, favorable outcomes were obtained in 65 cases (74.7%), relapses were 22 (25.3%). A high concordance in stenosis locations by CT and SPECT was noted in 60 cases of those who improved (92.3%) and 3 cases of those who relapsed (13.6%). The value of information provided by SPECT/CT has proved high in patients with nasolacrimal duct stenosis or obstruction. A combined scan allows to establish causal relationships between anatomical changes

  7. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  8. Three Dimensional Digital Sieving of Asphalt Mixture Based on X-ray Computed Tomography

    OpenAIRE

    Chichun Hu; Jiexian Ma; M. Emin Kutay

    2017-01-01

    In order to perform three-dimensional digital sieving based on X-ray computed tomography images, the definition of digital sieve size (DSS) was proposed, which was defined as the minimum length of the minimum bounding squares of all possible orthographic projections of an aggregate. The corresponding program was developed to reconstruct aggregate structure and to obtain DSS. Laboratory experiments consisting of epoxy-filled aggregate specimens were conducted to investigate the difference betw...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  13. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  14. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  15. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  18. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  19. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  2. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Kitslaar, Pieter H.; Broersen, Alexander

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model- based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) im- ages on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods...

  3. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  4. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  5. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  6. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  7. A computed tomography-based spatial normalization for the analysis of [18F] fluorodeoxyglucose positron emission tomography of the brain.

    Science.gov (United States)

    Cho, Hanna; Kim, Jin Su; Choi, Jae Yong; Ryu, Young Hoon; Lyoo, Chul Hyoung

    2014-01-01

    We developed a new computed tomography (CT)-based spatial normalization method and CT template to demonstrate its usefulness in spatial normalization of positron emission tomography (PET) images with [(18)F] fluorodeoxyglucose (FDG) PET studies in healthy controls. Seventy healthy controls underwent brain CT scan (120 KeV, 180 mAs, and 3 mm of thickness) and [(18)F] FDG PET scans using a PET/CT scanner. T1-weighted magnetic resonance (MR) images were acquired for all subjects. By averaging skull-stripped and spatially-normalized MR and CT images, we created skull-stripped MR and CT templates for spatial normalization. The skull-stripped MR and CT images were spatially normalized to each structural template. PET images were spatially normalized by applying spatial transformation parameters to normalize skull-stripped MR and CT images. A conventional perfusion PET template was used for PET-based spatial normalization. Regional standardized uptake values (SUV) measured by overlaying the template volume of interest (VOI) were compared to those measured with FreeSurfer-generated VOI (FSVOI). All three spatial normalization methods underestimated regional SUV values by 0.3-20% compared to those measured with FSVOI. The CT-based method showed slightly greater underestimation bias. Regional SUV values derived from all three spatial normalization methods were correlated significantly (p normalization may be an alternative method for structure-based spatial normalization of [(18)F] FDG PET when MR imaging is unavailable. Therefore, it is useful for PET/CT studies with various radiotracers whose uptake is expected to be limited to specific brain regions or highly variable within study population.

  8. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  9. General rigid motion correction for computed tomography imaging based on locally linear embedding

    Science.gov (United States)

    Chen, Mianyi; He, Peng; Feng, Peng; Liu, Baodong; Yang, Qingsong; Wei, Biao; Wang, Ge

    2018-02-01

    The patient motion can damage the quality of computed tomography images, which are typically acquired in cone-beam geometry. The rigid patient motion is characterized by six geometric parameters and are more challenging to correct than in fan-beam geometry. We extend our previous rigid patient motion correction method based on the principle of locally linear embedding (LLE) from fan-beam to cone-beam geometry and accelerate the computational procedure with the graphics processing unit (GPU)-based all scale tomographic reconstruction Antwerp toolbox. The major merit of our method is that we need neither fiducial markers nor motion-tracking devices. The numerical and experimental studies show that the LLE-based patient motion correction is capable of calibrating the six parameters of the patient motion simultaneously, reducing patient motion artifacts significantly.

  10. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    Science.gov (United States)

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  11. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  12. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography.

    Science.gov (United States)

    Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P

    2014-11-01

    Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  13. Model-based image reconstruction in X-ray computed tomography

    NARCIS (Netherlands)

    Zbijewski, Wojciech Bartosz

    2006-01-01

    The thesis investigates the applications of iterative, statistical reconstruction (SR) algorithms in X-ray Computed Tomography. Emphasis is put on various aspects of system modeling in statistical reconstruction. Fundamental issues such as effects of object discretization and algorithm

  14. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  15. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  16. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  17. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  18. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  19. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  20. Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours

    International Nuclear Information System (INIS)

    Amthauer, H.; Denecke, T.; Ruf, J.; Gutberlet, M.; Felix, R.; Lemke, A.J.; Rohlfing, T.; Boehmig, M.; Ploeckinger, U.

    2005-01-01

    The objective was the evaluation of single photon emission computed tomography (SPECT) with integrated low dose computed tomography (CT) in comparison with a retrospective fusion of SPECT and high-resolution CT and a side-by-side analysis for lesion localisation in patients with neuroendocrine tumours. Twenty-seven patients were examined by multidetector CT. Additionally, as part of somatostatin receptor scintigraphy (SRS), an integrated SPECT-CT was performed. SPECT and CT data were fused using software with a registration algorithm based on normalised mutual information. The reliability of the topographic assignment of lesions in SPECT-CT, retrospective fusion and side-by-side analysis was evaluated by two blinded readers. Two patients were not enrolled in the final analysis because of misregistrations in the retrospective fusion. Eighty-seven foci were included in the analysis. For the anatomical assignment of foci, SPECT-CT and retrospective fusion revealed overall accuracies of 91 and 94% (side-by-side analysis 86%). The correct identification of foci as lymph node manifestations (n=25) was more accurate by retrospective fusion (88%) than from SPECT-CT images (76%) or by side-by-side analysis (60%). Both modalities of image fusion appear to be well suited for the localisation of SRS foci and are superior to side-by-side analysis of non-fused images especially concerning lymph node manifestations. (orig.)

  1. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  2. Generation of three-dimensional prototype models based on cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, J.T.; Berndt, D.C.; Zehnder, M. [University of Basel, Department of Oral Surgery, University Hospital for Oral Surgery, Oral Radiology and Oral Medicine, Basel (Switzerland); Schumacher, R. [University of Applied Sciences Northwestern Switzerland, School of Life Sciences, Institute for Medical and Analytical Technologies, Muttenz (Switzerland)

    2009-03-15

    The purpose of this study was to generate three-dimensional models based on digital volumetric data that can be used in basic and advanced education. Four sets of digital volumetric data were established by cone beam computed tomography (CBCT) (Accuitomo, J. Morita, Kyoto, Japan). Datasets were exported as Dicom formats and imported into Mimics and Magic software programs to separate the different tissues such as nerve, tooth and bone. These data were transferred to a Polyjet 3D Printing machine (Eden 330, Object, Israel) to generate the models. Three-dimensional prototype models of certain limited anatomical structures as acquired volumetrically were fabricated. Generating three-dimensional models based on CBCT datasets is possible. Automated routine fabrication of these models, with the given infrastructure, is too time-consuming and therefore too expensive. (orig.)

  3. Generation of three-dimensional prototype models based on cone beam computed tomography

    International Nuclear Information System (INIS)

    Lambrecht, J.T.; Berndt, D.C.; Zehnder, M.; Schumacher, R.

    2009-01-01

    The purpose of this study was to generate three-dimensional models based on digital volumetric data that can be used in basic and advanced education. Four sets of digital volumetric data were established by cone beam computed tomography (CBCT) (Accuitomo, J. Morita, Kyoto, Japan). Datasets were exported as Dicom formats and imported into Mimics and Magic software programs to separate the different tissues such as nerve, tooth and bone. These data were transferred to a Polyjet 3D Printing machine (Eden 330, Object, Israel) to generate the models. Three-dimensional prototype models of certain limited anatomical structures as acquired volumetrically were fabricated. Generating three-dimensional models based on CBCT datasets is possible. Automated routine fabrication of these models, with the given infrastructure, is too time-consuming and therefore too expensive. (orig.)

  4. Skull base osteomyelitis in otitis externa: The utility of triphasic and single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Gupta, Ashok Kumar; Panda, Naresh Kumar; Das, Ashim; Mittal, Bhagwant Rai

    2013-01-01

    Skull base osteomyelitis (SBO) refers to infection that has spread beyond the external auditory canal to the base of the skull in advanced stages of otitis externa. Clinically, it may be difficult to differentiate SBO from severe otitis externa without bony involvement. This study was performed to determine the role of three phase bone scintigraphy (TPBS) and single photon emission tomography/computed tomography (SPECT/CT) in detecting SBO. We retrospectively analyzed records of 20 patients (14 M, 6 F) with otitis externa and suspected SBO. TPBS and SPECT/CT of the skull were performed. Findings were correlated with clinical, laboratory and diagnostic CT scan findings. All patients were diabetic with elevated erythrocyte sedimentation rate. A total of 18 patients had bilateral and two unilateral symptoms. Cranial nerves were involved in eight patients and microbiological culture of ear discharge fluid positive in seven. Early images showed increased temporal vascularity in nine patients and increased soft-tissue uptake in 10, while delayed images showed increased bone uptake in 19/20 patients. Localized abnormal tracer uptake was shown by SPECT/CT in the mastoid temporal (15), petrous (11), sphenoid (3) and zygomatic (1) and showed destructive changes in five. Thus, TPBS was found positive for SBO in 10/20 patients and changed the management in four. Our study suggests that TPBS with SPECT/CT is a useful non-invasive investigation for detection of SBO in otitis externa

  5. Influence of 18F-fluorodeoxyglucose-positron emission tomography on computed tomography-based radiation treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Everitt, C.; Leong, T.

    2006-01-01

    The addition of positron emission tomography (PET) information to CT-based radiotherapy treatment planning has the potential to improve target volume definition through more accurate localization of the primary tumour and involved regional lymph nodes. This case report describes the first patient enrolled to a prospective study evaluating the effects of coregistered positron emission tomography/CT images on radiotherapy treatment planning for oesophageal cancer. The results show that if combined positron emission tomography/CT is used for radiotherapy treatment planning, there may be alterations to the delineation of tumour volumes when compared to CT alone. For this patient, a geographic miss of tumour would have occurred if CT data alone were used for radiotherapy planning Copyright (2006) Blackwell Publishing Asia Pty Ltd

  6. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  7. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  8. Grating-based X-ray Dark-field Computed Tomography of Living Mice.

    Science.gov (United States)

    Velroyen, A; Yaroshenko, A; Hahn, D; Fehringer, A; Tapfer, A; Müller, M; Noël, P B; Pauwels, B; Sasov, A; Yildirim, A Ö; Eickelberg, O; Hellbach, K; Auweter, S D; Meinel, F G; Reiser, M F; Bech, M; Pfeiffer, F

    2015-10-01

    Changes in x-ray attenuating tissue caused by lung disorders like emphysema or fibrosis are subtle and thus only resolved by high-resolution computed tomography (CT). The structural reorganization, however, is of strong influence for lung function. Dark-field CT (DFCT), based on small-angle scattering of x-rays, reveals such structural changes even at resolutions coarser than the pulmonary network and thus provides access to their anatomical distribution. In this proof-of-concept study we present x-ray in vivo DFCTs of lungs of a healthy, an emphysematous and a fibrotic mouse. The tomographies show excellent depiction of the distribution of structural - and thus indirectly functional - changes in lung parenchyma, on single-modality slices in dark field as well as on multimodal fusion images. Therefore, we anticipate numerous applications of DFCT in diagnostic lung imaging. We introduce a scatter-based Hounsfield Unit (sHU) scale to facilitate comparability of scans. In this newly defined sHU scale, the pathophysiological changes by emphysema and fibrosis cause a shift towards lower numbers, compared to healthy lung tissue.

  9. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  10. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  11. Slice image pretreatment for cone-beam computed tomography based on adaptive filter

    International Nuclear Information System (INIS)

    Huang Kuidong; Zhang Dinghua; Jin Yanfang

    2009-01-01

    According to the noise properties and the serial slice image characteristics in Cone-Beam Computed Tomography (CBCT) system, a slice image pretreatment for CBCT based on adaptive filter was proposed. The judging criterion for the noise is established firstly. All pixels are classified into two classes: adaptive center weighted modified trimmed mean (ACWMTM) filter is used for the pixels corrupted by Gauss noise and adaptive median (AM) filter is used for the pixels corrupted by impulse noise. In ACWMTM filtering algorithm, the estimated Gauss noise standard deviation in the current slice image with offset window is replaced by the estimated standard deviation in the adjacent slice image to the current with the corresponding window, so the filtering accuracy of the serial images is improved. The pretreatment experiment on CBCT slice images of wax model of hollow turbine blade shows that the method makes a good performance both on eliminating noises and on protecting details. (authors)

  12. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D. [UCSF Benioff Children' s Hospital, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2014-07-15

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model-based

  13. Accuracy of volumetric measurement of simulated root resorption lacunas based on cone beam computed tomography.

    Science.gov (United States)

    Wang, Y; He, S; Guo, Y; Wang, S; Chen, S

    2013-08-01

    To evaluate the accuracy of volumetric measurement of simulated root resorption cavities based on cone beam computed tomography (CBCT), in comparison with that of Micro-computed tomography (Micro-CT) which served as the reference. The State Key Laboratory of Oral Diseases at Sichuan University. Thirty-two bovine teeth were included for standardized CBCT scanning and Micro-CT scanning before and after the simulation of different degrees of root resorption. The teeth were divided into three groups according to the depths of the root resorption cavity (group 1: 0.15, 0.2, 0.3 mm; group 2: 0.6, 1.0 mm; group 3: 1.5, 2.0, 3.0 mm). Each depth included four specimens. Differences in tooth volume before and after simulated root resorption were then calculated from CBCT and Micro-CT scans, respectively. The overall between-method agreement of the measurements was evaluated using the concordance correlation coefficient (CCC). For the first group, the average volume of resorption cavity was 1.07 mm(3) , and the between-method agreement of measurement for the volume changes was low (CCC = 0.098). For the second and third groups, the average volumes of resorption cavities were 3.47 and 6.73 mm(3) respectively, and the between-method agreements were good (CCC = 0.828 and 0.895, respectively). The accuracy of 3-D quantitative volumetric measurement of simulated root resorption based on CBCT was fairly good in detecting simulated resorption cavities larger than 3.47 mm(3), while it was not sufficient for measuring resorption cavities smaller than 1.07 mm(3) . This method could be applied in future studies of root resorption although further studies are required to improve its accuracy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    International Nuclear Information System (INIS)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D.

    2014-01-01

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model-based

  15. High performance graphics processor based computed tomography reconstruction algorithms for nuclear and other large scale applications.

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, Edward S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Orr, Laurel J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Thompson, Kyle R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-09-01

    The goal of this work is to develop a fast computed tomography (CT) reconstruction algorithm based on graphics processing units (GPU) that achieves significant improvement over traditional central processing unit (CPU) based implementations. The main challenge in developing a CT algorithm that is capable of handling very large datasets is parallelizing the algorithm in such a way that data transfer does not hinder performance of the reconstruction algorithm. General Purpose Graphics Processing (GPGPU) is a new technology that the Science and Technology (S&T) community is starting to adopt in many fields where CPU-based computing is the norm. GPGPU programming requires a new approach to algorithm development that utilizes massively multi-threaded environments. Multi-threaded algorithms in general are difficult to optimize since performance bottlenecks occur that are non-existent in single-threaded algorithms such as memory latencies. If an efficient GPU-based CT reconstruction algorithm can be developed; computational times could be improved by a factor of 20. Additionally, cost benefits will be realized as commodity graphics hardware could potentially replace expensive supercomputers and high-end workstations. This project will take advantage of the CUDA programming environment and attempt to parallelize the task in such a way that multiple slices of the reconstruction volume are computed simultaneously. This work will also take advantage of the GPU memory by utilizing asynchronous memory transfers, GPU texture memory, and (when possible) pinned host memory so that the memory transfer bottleneck inherent to GPGPU is amortized. Additionally, this work will take advantage of GPU-specific hardware (i.e. fast texture memory, pixel-pipelines, hardware interpolators, and varying memory hierarchy) that will allow for additional performance improvements.

  16. Efficacy of navigation in skull base surgery using composite computer graphics of magnetic resonance and computed tomography images

    International Nuclear Information System (INIS)

    Hayashi, Nakamasa; Kurimoto, Masanori; Hirashima, Yutaka; Ikeda, Hiroaki; Shibata, Takashi; Tomita, Takahiro; Endo, Shunro

    2001-01-01

    The efficacy of a neurosurgical navigation system using three-dimensional composite computer graphics (CGs) of magnetic resonance (MR) and computed tomography (CT) images was evaluated in skull base surgery. Three-point transformation was used for integration of MR and CT images. MR and CT image data were obtained with three skin markers placed on the patient's scalp. Volume-rendering manipulations of the data produced three-dimensional CGs of the scalp, brain, and lesions from the MR images, and the scalp and skull from the CT. Composite CGs of the scalp, skull, brain, and lesion were created by registering the three markers on the three-dimensional rendered scalp images obtained from MR imaging and CT in the system. This system was used for 14 patients with skull base lesions. Three-point transformation using three-dimensional CGs was easily performed for multimodal registration. Simulation of surgical procedures on composite CGs aided in comprehension of the skull base anatomy and selection of the optimal approaches. Intraoperative navigation aided in determination of actual spatial position in the skull base and the optimal trajectory to the tumor during surgical procedures. (author)

  17. Clinicopathological and immunohistochemical features of lung invasive mucinous adenocarcinoma based on computed tomography findings

    Directory of Open Access Journals (Sweden)

    Shimizu K

    2016-12-01

    Full Text Available Katsuhiko Shimizu, Riki Okita, Shinsuke Saisho, Ai Maeda, Yuji Nojima, Masao Nakata Department of General Thoracic Surgery, Kawasaki Medical School, Kurashiki, Okayama, Japan Background: We performed an analysis to clarify differences in clinicopathological and molecular features of lung invasive mucinous adenocarcinoma (IMA based on computed tomography (CT findings and their impact on prognosis.Patients and methods: On the basis of CT findings, we divided lung IMA into three subtypes: solid, bubbling, and pneumonic. We then investigated differences in clinicopathological characteristics, prognosis, and the expressions of well-identified biomarkers, including cyclooxygenase-2 (Cox-2, excision repair cross-complementation group 1 (ERCC1, ribonucleotide reductase M1 (RRM1, class III beta-tubulin, thymidylate synthase (TS, secreted protein acidic and rich in cysteine (SPARC, programmed cell death-1 ligand-1 (PD-L1, and epidermal growth factor receptor mutation, among the three subtypes.Results: A total of 29 patients with resected lung IMA were analyzed. Compared with the solid or bubbling type, the pneumonic type had a higher proportion of symptoms, a larger tumor size, a higher pathological stage, and a significantly worse prognosis. The immunohistochemical findings tended to show high expression of RRM1, class III beta-tubulin, and Cox-2 in the tumor and of SPARC in the stroma, but not of ERCC1, TS, and PD-L1 in the tumor. None of the biomarkers with high expression levels in the tumor were prognostic biomarkers, but the expression of SPARC in the stroma was correlated with a poor outcome.Conclusion: Clinical and pathological features, in conjunction with molecular data, indicate that IMA should be divided into different subgroups. In our results, the pneumonic type was correlated with a significantly worse outcome. Further studies should be performed to confirm our conclusion and to explore its molecular implications. Keywords: non-small cell

  18. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Fairbairn, I.A.

    1984-01-01

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  19. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  20. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  1. Fourier-based approach to interpolation in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2001-01-01

    It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal direction and because the exploitation of the redundancy of fanbeam data acquired over 360 degree sign to generate additional longitudinal samples does not automatically eliminate the aliasing. In this paper we demonstrate that for pitches near 1 or lower, the redundant fanbeam data, when used properly, can provide sufficient information to satisfy a generalized sampling theorem and thus to eliminate aliasing. We develop and evaluate a Fourier-based algorithm, called 180FT, that accomplishes this. As background we present a second Fourier-based approach, called 360FT, that makes use only of the directly measured data. Both Fourier-based approaches exploit the fast Fourier transform and the Fourier shift theorem to generate from the helical projection data a set of fanbeam sinograms corresponding to equispaced transverse slices. Slice-by-slice reconstruction is then performed by use of two-dimensional fanbeam algorithms. The proposed approaches are compared to their counterparts based on the use of linear interpolation - the 360LI and 180LI approaches. The aliasing suppression property of the 180FT approach is a clear advantage of the approach and represents a step toward the desirable goal of achieving uniform longitudinal resolution properties in reconstructed helical CT volumes

  2. Cone-beam x-ray luminescence computed tomography based on x-ray absorption dosage

    Science.gov (United States)

    Liu, Tianshuai; Rong, Junyan; Gao, Peng; Zhang, Wenli; Liu, Wenlei; Zhang, Yuanke; Lu, Hongbing

    2018-02-01

    With the advances of x-ray excitable nanophosphors, x-ray luminescence computed tomography (XLCT) has become a promising hybrid imaging modality. In particular, a cone-beam XLCT (CB-XLCT) system has demonstrated its potential in in vivo imaging with the advantage of fast imaging speed over other XLCT systems. Currently, the imaging models of most XLCT systems assume that nanophosphors emit light based on the intensity distribution of x-ray within the object, not completely reflecting the nature of the x-ray excitation process. To improve the imaging quality of CB-XLCT, an imaging model that adopts an excitation model of nanophosphors based on x-ray absorption dosage is proposed in this study. To solve the ill-posed inverse problem, a reconstruction algorithm that combines the adaptive Tikhonov regularization method with the imaging model is implemented for CB-XLCT reconstruction. Numerical simulations and phantom experiments indicate that compared with the traditional forward model based on x-ray intensity, the proposed dose-based model could improve the image quality of CB-XLCT significantly in terms of target shape, localization accuracy, and image contrast. In addition, the proposed model behaves better in distinguishing closer targets, demonstrating its advantage in improving spatial resolution.

  3. The Dimensions of the Orbital Cavity Based on High-Resolution Computed Tomography of Human Cadavers

    DEFF Research Database (Denmark)

    Felding, Ulrik Ascanius; Bloch, Sune Land; Buchwald, Christian von

    2016-01-01

    for surface area. To authors' knowledge, this study is the first to have measured the entire surface area of the orbital cavity.The volume and surface area of the orbital cavity were estimated in computed tomography scans of 11 human cadavers using unbiased stereological sampling techniques. The mean (± SD......) total volume and total surface area of the orbital cavities was 24.27 ± 3.88 cm and 32.47 ± 2.96 cm, respectively. There was no significant difference in volume (P = 0.315) or surface area (P = 0.566) between the 2 orbital cavities.The stereological technique proved to be a robust and unbiased method...... that may be used as a gold standard for comparison with automated computer software. Future imaging studies in blow-out fracture patients may be based on individual and relative calculation involving both herniated volume and fractured surface area in relation to the total volume and surface area...

  4. Nasal and skull base anatomy of endoscopic endonasal transsphenoidal surgery with multi-detector computed tomography

    International Nuclear Information System (INIS)

    Hasegawa, Yuzo; Saeki, Naokatsu; Murai, Hisayuki; Horiguchi, Kentaro; Hanazawa, Toyoyuki; Okamoto, Miyoshi; Yanagawa, Noriyuki

    2008-01-01

    The endoscope is a new and highly useful instrument for transphenoidal surgery (TSS), and is generally used because of its minimally invasiveness. In addition, endoscopic transsphenoidal surgey (eTSS) has a potential for more radical tumor removal at the pituitary and the parasellar regions by wider visualization and more powerful illumination. To operate these regions safely, we need to know nasal and skull base anatomy under the endoscope which looks different from images under a microscope. In this paper, we demonstrated nasal and skull base anatomy with multi-detector computed tomography, which was performed in 23 recent patients with pituitary and parasellar legions. In the nasal legion, deviation of nasal septum and deviation of sphenoid ostium are important for endonasal approach of eTSS, and often determine the difficulty of surgery in the nasal cavity. Our study showed that deviation of nasal septum was seen in 26% of patients. Deviation of sphenoid ostium was 5.5±1.5 mm from the midline. The anatomy of sphenoid sinus plays a key role in our determination of the safety of a bony opening of the sella. In addition to sellar, presellar, and concha types, carotid prominence and optic prominence are important to determine the midline orientation. Development of carotid prominence was significantly related to the extent of lateral pneumatization of sphenoid sinus (P=0.0016). Reconstructed 3D-image of sphenoid sinus was very useful in visual understanding skull base anatomy. (author)

  5. Feasibility of computed tomography based thermometry during interstitial laser heating in bovine liver

    International Nuclear Information System (INIS)

    Pandeya, G.D.; Klaessens, J.H.G.M.; Greuter, M.J.W.; Oudkerk, M.; Schmidt, B.; Flohr, T.; Hillegersberg, R. van

    2011-01-01

    To assess the feasibility of computed tomography (CT) based thermometry during interstitial laser heating in the bovine liver. Four freshly exercised cylindrical blocks of bovine tissue were heated using a continuous laser of Nd:YAG (wavelength: 1064 nm, active length: 30 mm, power: 10-30 W). All tissues were imaged at least once before and 7 times during laser heating using CT and temperatures were simultaneously measured with 5 calibrated thermal sensors. The dependency of the average CT numbers as a function of temperature was analysed with regression analysis and a CT thermal sensitivity was derived. During laser heating, the growing hypodense area was observed around the laser source and that area showed an increase as a function of time. The formation of hypodense area was caused by declining in CT numbers at increasing temperatures. The regression analysis showed an inverse linear dependency between temperature and average CT number with -0.65 ± 0.048 HU/ C (R 2 = 0.75) for the range of 18-85 C in bovine liver. The non-invasive CT based thermometry during interstitial laser heating is feasible in the bovine liver. CT based thermometry could be further developed and may be of potential use during clinical LITT of the liver. (orig.)

  6. Comparison between computed tomography with oral oil-based contrast and laparotomy for gastric cancer staging

    International Nuclear Information System (INIS)

    Marco, S. F.; Garcia-Vila, J. H.; Cervera, J.; Gomez, R.; Piqueras, R. M.; Perona, I.; Escrig, J.; Salvador, J. L.

    2000-01-01

    To compare the utility of conventional computed tomography (CT) with oral oil-based contrast with that of laparotomy in the preoperative staging of gastric cancer. We prospectively studied 41 patients diagnosed as having gastric adenocarcinoma according to the results of endoscopy and biopsy. Applying the TNM classification for gastric cancer staging, we compared the findings in CT associated with oral oil-based contrast and intraoperative staging with definitive postoperative pathological staging. Definitive pathological studies demonstrated that there were 7 stage T1-T2 lesions, 26 stage T3 and 8 stage T4. The assessment of lymph node involvement showed that 10 patients presented stage N0 and 31 stage N1-N3. Ten patients had metastases. The diagnostic reliability for tumor staging according to CT was 56% versus 80% for laparotomy. In the determination of nodal involvement CT had a diagnostic yield of 71% versus 6% for laparotomy. Metastatic disease was correctly diagnosed by CT in 83% of cases versus 88% by laparotomy. There were no statistically significant differences between CT with oral oil-based contrast and laparotomy for the staging of nodal involvement and metastases. However, the CT diagnosis was significantly more reliable than laparotomy for the determination of tumor infiltration. (Author) 21 refs

  7. Seismocardiography-Based Cardiac Computed Tomography Gating Using Patient-Specific Template Identification and Detection.

    Science.gov (United States)

    Yao, Jingting; Tridandapani, Srini; Wick, Carson A; Bhatti, Pamela T

    2017-01-01

    To more accurately trigger cardiac computed tomography angiography (CTA) than electrocardiography (ECG) alone, a sub-system is proposed as an intermediate step toward fusing ECG with seismocardiography (SCG). Accurate prediction of quiescent phases is crucial to prospectively gating CTA, which is susceptible to cardiac motion and, thus, can affect the diagnostic quality of images. The key innovation of this sub-system is that it identifies the SCG waveform corresponding to heart sounds and determines their phases within the cardiac cycles. Furthermore, this relationship is modeled as a linear function with respect to heart rate. For this paper, B-mode echocardiography is used as the gold standard for identifying the quiescent phases. We analyzed synchronous ECG, SCG, and echocardiography data acquired from seven healthy subjects (mean age: 31; age range: 22-48; males: 4) and 11 cardiac patients (mean age: 56; age range: 31-78; males: 6). On average, the proposed algorithm was able to successfully identify 79% of the SCG waveforms in systole and 68% in diastole. The simulated results show that SCG-based prediction produced less average phase error than that of ECG. It was found that the accuracy of ECG-based gating is more susceptible to increases in heart rate variability, while SCG-based gating is susceptible to high cycle to cycle variability in morphology. This pilot work of prediction using SCG waveforms enriches the framework of a comprehensive system with multiple modalities that could potentially, in real time, improve the image quality of CTA.

  8. Simple area-based measurement for multidetector computed tomography to predict left ventricular size

    International Nuclear Information System (INIS)

    Schlett, Christopher L.; Kwait, Dylan C.; Mahabadi, Amir A.; Hoffmann, Udo; Bamberg, Fabian; O'Donnell, Christopher J.; Fox, Caroline S.

    2010-01-01

    Measures of left ventricular (LV) mass and dimensions are independent predictors of morbidity and mortality. We determined whether an axial area-based method by computed tomography (CT) provides an accurate estimate of LV mass and volume. A total of 45 subjects (49% female, 56.0 ± 12 years) with a wide range of LV geometry underwent contrast-enhanced 64-slice CT. LV mass and volume were derived from 3D data. 2D images were analysed to determine LV area, the direct transverse cardiac diameter (dTCD) and the cardiothoracic ratio (CTR). Furthermore, feasibility was confirmed in 100 Framingham Offspring Cohort subjects. 2D measures of LV area, dTCD and CTR were 47.3 ± 8 cm 2 , 14.7 ± 1.5 cm and 0.54 ± 0.05, respectively. 3D-derived LV volume (end-diastolic) and mass were 148.9 ± 45 cm 3 and 124.2 ± 34 g, respectively. Excellent inter- and intra-observer agreement were shown for 2D LV area measurements (both intraclass correlation coefficients (ICC) = 0.99, p 0.27). Compared with traditionally used CTR, LV size can be accurately predicted based on a simple and highly reproducible axial LV area-based measurement. (orig.)

  9. Cone Beam X-ray Luminescence Computed Tomography Based on Bayesian Method.

    Science.gov (United States)

    Zhang, Guanglei; Liu, Fei; Liu, Jie; Luo, Jianwen; Xie, Yaoqin; Bai, Jing; Xing, Lei

    2017-01-01

    X-ray luminescence computed tomography (XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. Combining the principles of X-ray excitation of luminescence-based probes and optical signal detection, XLCT naturally fuses functional and anatomical images and provides complementary information for a wide range of applications in biomedical research. In order to improve the data acquisition efficiency of previously developed narrow-beam XLCT, a cone beam XLCT (CB-XLCT) mode is adopted here to take advantage of the useful geometric features of cone beam excitation. Practically, a major hurdle in using cone beam X-ray for XLCT is that the inverse problem here is seriously ill-conditioned, hindering us to achieve good image quality. In this paper, we propose a novel Bayesian method to tackle the bottleneck in CB-XLCT reconstruction. The method utilizes a local regularization strategy based on Gaussian Markov random field to mitigate the ill-conditioness of CB-XLCT. An alternating optimization scheme is then used to automatically calculate all the unknown hyperparameters while an iterative coordinate descent algorithm is adopted to reconstruct the image with a voxel-based closed-form solution. Results of numerical simulations and mouse experiments show that the self-adaptive Bayesian method significantly improves the CB-XLCT image quality as compared with conventional methods.

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  11. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  17. Assessment of an organ‐based tube current modulation in thoracic computed tomography

    Science.gov (United States)

    Sugai, Mai; Toyoda, Asami; Koshida, Haruka; Sakuta, Keita; Takata, Tadanori; Koshida, Kichiro; Iida, Hiroji; Matsui, Osamu

    2012-01-01

    Recently, specific computed tomography (CT) scanners have been equipped with organ‐based tube current modulation (TCM) technology. It is possible that organ‐based TCM will replace the conventional dose‐reduction technique of reducing the effective milliampere‐second. The aim of this study was to determine if organ‐based TCM could reduce radiation exposure to the breasts without compromising the image uniformity and beam hardening effect in thoracic CT examinations. Breast and skin radiation doses and the absorbed radiation dose distribution within a single section were measured with an anthropomorphic phantom and radiophotoluminescent glass dosimeters using four approaches to thoracic CT (reference, organ‐based TCM, copper shielding, and the combination of the above two techniques, hereafter referred to as the combination technique). The CT value and noise level were measured using the same calibration phantom. Organ‐based TCM and copper shielding reduced radiation doses to the breast by 23.7% and 21.8%, respectively. However, the CT value increased, especially in the anterior region, using copper shielding. In contrast, the CT value and noise level barely increased using organ‐based TCM. The combination technique reduced the radiation dose to the breast by 38.2%, but greatly increased the absorbed radiation dose from the central to the posterior regions. Moreover, the CT value increased in the anterior region and the noise level increased by more than 10% in the entire region. Therefore, organ‐based TCM can reduce radiation doses to breasts with only small increases in noise levels, making it preferable for specific groups of patients, such as children and young women. PACS numbers: 87.53.Bn; 87.57.Q‐; 87.57.qp PMID:22402390

  18. Assessment of an organ-based tube current modulation in thoracic computed tomography.

    Science.gov (United States)

    Matsubara, Kosuke; Sugai, Mai; Toyoda, Asami; Koshida, Haruka; Sakuta, Keita; Takata, Tadanori; Koshida, Kichiro; Iida, Hiroji; Matsui, Osamu

    2012-03-08

    Recently, specific computed tomography (CT) scanners have been equipped with organ-based tube current modulation (TCM) technology. It is possible that organ-based TCM will replace the conventional dose-reduction technique of reducing the effective milliampere-second. The aim of this study was to determine if organ-based TCM could reduce radiation exposure to the breasts without compromising the image uniformity and beam hardening effect in thoracic CT examinations. Breast and skin radiation doses and the absorbed radiation dose distribution within a single section were measured with an anthropomorphic phantom and radiophotoluminescent glass dosimeters using four approaches to thoracic CT (reference, organ-based TCM, copper shielding, and the combination of the above two techniques, hereafter referred to as the combination technique). The CT value and noise level were measured using the same calibration phantom. Organ-based TCM and copper shielding reduced radiation doses to the breast by 23.7% and 21.8%, respectively. However, the CT value increased, especially in the anterior region, using copper shielding. In contrast, the CT value and noise level barely increased using organ-based TCM. The combination technique reduced the radiation dose to the breast by 38.2%, but greatly increased the absorbed radiation dose from the central to the posterior regions. Moreover, the CT value increased in the anterior region and the noise level increased by more than 10% in the entire region. Therefore, organ-based TCM can reduce radiation doses to breasts with only small increases in noise levels, making it preferable for specific groups of patients, such as children and young women.

  19. A compressed sensing based reconstruction algorithm for synchrotron source propagation-based X-ray phase contrast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Melli, Seyed Ali, E-mail: sem649@mail.usask.ca [Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK (Canada); Wahid, Khan A. [Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK (Canada); Babyn, Paul [Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK (Canada); Montgomery, James [College of Medicine, University of Saskatchewan, Saskatoon, SK (Canada); Snead, Elisabeth [Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK (Canada); El-Gayed, Ali [College of Medicine, University of Saskatchewan, Saskatoon, SK (Canada); Pettitt, Murray; Wolkowski, Bailey [College of Agriculture and Bioresources, University of Saskatchewan, Saskatoon, SK (Canada); Wesolowski, Michal [Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK (Canada)

    2016-01-11

    Synchrotron source propagation-based X-ray phase contrast computed tomography is increasingly used in pre-clinical imaging. However, it typically requires a large number of projections, and subsequently a large radiation dose, to produce high quality images. To improve the applicability of this imaging technique, reconstruction algorithms that can reduce the radiation dose and acquisition time without degrading image quality are needed. The proposed research focused on using a novel combination of Douglas–Rachford splitting and randomized Kaczmarz algorithms to solve large-scale total variation based optimization in a compressed sensing framework to reconstruct 2D images from a reduced number of projections. Visual assessment and quantitative performance evaluations of a synthetic abdomen phantom and real reconstructed image of an ex-vivo slice of canine prostate tissue demonstrate that the proposed algorithm is competitive in reconstruction process compared with other well-known algorithms. An additional potential benefit of reducing the number of projections would be reduction of time for motion artifact to occur if the sample moves during image acquisition. Use of this reconstruction algorithm to reduce the required number of projections in synchrotron source propagation-based X-ray phase contrast computed tomography is an effective form of dose reduction that may pave the way for imaging of in-vivo samples.

  20. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  1. Three Dimensional Digital Sieving of Asphalt Mixture Based on X-ray Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chichun Hu

    2017-07-01

    Full Text Available In order to perform three-dimensional digital sieving based on X-ray computed tomography images, the definition of digital sieve size (DSS was proposed, which was defined as the minimum length of the minimum bounding squares of all possible orthographic projections of an aggregate. The corresponding program was developed to reconstruct aggregate structure and to obtain DSS. Laboratory experiments consisting of epoxy-filled aggregate specimens were conducted to investigate the difference between mechanical sieve analysis and the digital sieving technique. It was suggested that concave surface of aggregate was the possible reason for the disparity between DSS and mechanical sieve size. A comparison between DSS and equivalent diameter was also performed. Moreover, the digital sieving technique was adopted to evaluate the gradation of stone mastic asphalt mixtures. The results showed that the closest proximity of the laboratory gradation curve was achieved by calibrated DSS, among gradation curves based on calibrated DSS, un-calibrated DSS and equivalent diameter.

  2. Incomplete projection reconstruction of computed tomography based on the modified discrete algebraic reconstruction technique

    Science.gov (United States)

    Yang, Fuqiang; Zhang, Dinghua; Huang, Kuidong; Gao, Zongzhao; Yang, YaFei

    2018-02-01

    Based on the discrete algebraic reconstruction technique (DART), this study aims to address and test a new improved algorithm applied to incomplete projection data to generate a high quality reconstruction image by reducing the artifacts and noise in computed tomography. For the incomplete projections, an augmented Lagrangian based on compressed sensing is first used in the initial reconstruction for segmentation of the DART to get higher contrast graphics for boundary and non-boundary pixels. Then, the block matching 3D filtering operator was used to suppress the noise and to improve the gray distribution of the reconstructed image. Finally, simulation studies on the polychromatic spectrum were performed to test the performance of the new algorithm. Study results show a significant improvement in the signal-to-noise ratios (SNRs) and average gradients (AGs) of the images reconstructed from incomplete data. The SNRs and AGs of the new images reconstructed by DART-ALBM were on average 30%-40% and 10% higher than the images reconstructed by DART algorithms. Since the improved DART-ALBM algorithm has a better robustness to limited-view reconstruction, which not only makes the edge of the image clear but also makes the gray distribution of non-boundary pixels better, it has the potential to improve image quality from incomplete projections or sparse projections.

  3. Noninvasive Computed Tomography-based Risk Stratification of Lung Adenocarcinomas in the National Lung Screening Trial.

    Science.gov (United States)

    Maldonado, Fabien; Duan, Fenghai; Raghunath, Sushravya M; Rajagopalan, Srinivasan; Karwoski, Ronald A; Garg, Kavita; Greco, Erin; Nath, Hrudaya; Robb, Richard A; Bartholmai, Brian J; Peikert, Tobias

    2015-09-15

    Screening for lung cancer using low-dose computed tomography (CT) reduces lung cancer mortality. However, in addition to a high rate of benign nodules, lung cancer screening detects a large number of indolent cancers that generally belong to the adenocarcinoma spectrum. Individualized management of screen-detected adenocarcinomas would be facilitated by noninvasive risk stratification. To validate that Computer-Aided Nodule Assessment and Risk Yield (CANARY), a novel image analysis software, successfully risk stratifies screen-detected lung adenocarcinomas based on clinical disease outcomes. We identified retrospective 294 eligible patients diagnosed with lung adenocarcinoma spectrum lesions in the low-dose CT arm of the National Lung Screening Trial. The last low-dose CT scan before the diagnosis of lung adenocarcinoma was analyzed using CANARY blinded to clinical data. Based on their parametric CANARY signatures, all the lung adenocarcinoma nodules were risk stratified into three groups. CANARY risk groups were compared using survival analysis for progression-free survival. A total of 294 patients were included in the analysis. Kaplan-Meier analysis of all the 294 adenocarcinoma nodules stratified into the Good, Intermediate, and Poor CANARY risk groups yielded distinct progression-free survival curves (P < 0.0001). This observation was confirmed in the unadjusted and adjusted (age, sex, race, and smoking status) progression-free survival analysis of all stage I cases. CANARY allows the noninvasive risk stratification of lung adenocarcinomas into three groups with distinct post-treatment progression-free survival. Our results suggest that CANARY could ultimately facilitate individualized management of incidentally or screen-detected lung adenocarcinomas.

  4. Radiomics-based differentiation of lung disease models generated by polluted air based on X-ray computed tomography data.

    Science.gov (United States)

    Szigeti, Krisztián; Szabó, Tibor; Korom, Csaba; Czibak, Ilona; Horváth, Ildikó; Veres, Dániel S; Gyöngyi, Zoltán; Karlinger, Kinga; Bergmann, Ralf; Pócsik, Márta; Budán, Ferenc; Máthé, Domokos

    2016-02-11

    Lung diseases (resulting from air pollution) require a widely accessible method for risk estimation and early diagnosis to ensure proper and responsive treatment. Radiomics-based fractal dimension analysis of X-ray computed tomography attenuation patterns in chest voxels of mice exposed to different air polluting agents was performed to model early stages of disease and establish differential diagnosis. To model different types of air pollution, BALBc/ByJ mouse groups were exposed to cigarette smoke combined with ozone, sulphur dioxide gas and a control group was established. Two weeks after exposure, the frequency distributions of image voxel attenuation data were evaluated. Specific cut-off ranges were defined to group voxels by attenuation. Cut-off ranges were binarized and their spatial pattern was associated with calculated fractal dimension, then abstracted by the fractal dimension -- cut-off range mathematical function. Nonparametric Kruskal-Wallis (KW) and Mann-Whitney post hoc (MWph) tests were used. Each cut-off range versus fractal dimension function plot was found to contain two distinctive Gaussian curves. The ratios of the Gaussian curve parameters are considerably significant and are statistically distinguishable within the three exposure groups. A new radiomics evaluation method was established based on analysis of the fractal dimension of chest X-ray computed tomography data segments. The specific attenuation patterns calculated utilizing our method may diagnose and monitor certain lung diseases, such as chronic obstructive pulmonary disease (COPD), asthma, tuberculosis or lung carcinomas.

  5. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

    Science.gov (United States)

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin

    2015-03-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (pimplants using micro-CT analysis using a region-based segmentation method.

  6. Lung nodule assessment in computed tomography. Precision of attenuation measurement based on computer-aided volumetry

    International Nuclear Information System (INIS)

    Knoess, Naomi; Hoffmann, B.; Fabel, M.; Wiese, C.; Bolte, H.; Heller, M.; Biederer, J.; Jochens, A.

    2009-01-01

    Purpose: to compare the reproducibility (r) of CT value measurement of pulmonary nodules using volumetry software (LungCare, LC) and manual ROIs (mROI). Materials and methods: 54 artificial nodules in a chest phantom were scanned three times with CT. CT values were measured with LC and mROI. The intrascan-r was assessed with three measurements in the first scan, and the interscan-r with measurements in three consecutive scans (one observer). Intrascan-r und interobserver-r (two obs.) were assessed in the first scan and in contrast-enhanced CT of 51 nodules from 15 patients (kernels b50f and b80f). Intrascan-r and interscan-r were described as the mean range and interobserver-r as the mean difference of CT values. The significance of differences was tested using t-test and sign test. Results: reproducibility was significantly higher for volumetry-based measurements in both artificial and patient nodules (range 0.11 vs. 6.16 HU for intrascan-r, 2.22 vs. 7.03 HU for interscan-r, difference 0.11 vs. 18.42 HU for interobserver-r; patients: 1.78 vs. 13.19 HU (b50f-Kernel) and 1.88 vs. 27.4 HU (b80f-Kernel) for intrascan-r, 3.71 vs. 22.43 HU for interobserver-r). Absolute CT values differed significantly between convolution kernels (pat./mROI: 29.3 [b50f] and 151.9 HU [b80f] pat./LC: 5 [b50f] and 147 HU [b80f]). Conclusion: the reproducibility of volumetry-based measurements of CT values in pulmonary nodules is significantly higher and should therefore be recommended, e.g. in dynamic chest CT protocols. Reproducibility does not depend on absolute CT values. (orig.)

  7. Adaptive tight frame based medical image reconstruction: a proof-of-concept study for computed tomography

    International Nuclear Information System (INIS)

    Zhou, Weifeng; Cai, Jian-Feng; Gao, Hao

    2013-01-01

    A popular approach for medical image reconstruction has been through the sparsity regularization, assuming the targeted image can be well approximated by sparse coefficients under some properly designed system. The wavelet tight frame is such a widely used system due to its capability for sparsely approximating piecewise-smooth functions, such as medical images. However, using a fixed system may not always be optimal for reconstructing a variety of diversified images. Recently, the method based on the adaptive over-complete dictionary that is specific to structures of the targeted images has demonstrated its superiority for image processing. This work is to develop the adaptive wavelet tight frame method image reconstruction. The proposed scheme first constructs the adaptive wavelet tight frame that is task specific, and then reconstructs the image of interest by solving an l 1 -regularized minimization problem using the constructed adaptive tight frame system. The proof-of-concept study is performed for computed tomography (CT), and the simulation results suggest that the adaptive tight frame method improves the reconstructed CT image quality from the traditional tight frame method. (paper)

  8. A novel image-domain-based cone-beam computed tomography enhancement algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiang; Li Tianfang; Yang Yong; Heron, Dwight E; Huq, M Saiful, E-mail: lix@upmc.edu [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, PA 15232 (United States)

    2011-05-07

    Kilo-voltage (kV) cone-beam computed tomography (CBCT) plays an important role in image-guided radiotherapy. However, due to a large cone-beam angle, scatter effects significantly degrade the CBCT image quality and limit its clinical application. The goal of this study is to develop an image enhancement algorithm to reduce the low-frequency CBCT image artifacts, which are also called the bias field. The proposed algorithm is based on the hypothesis that image intensities of different types of materials in CBCT images are approximately globally uniform (in other words, a piecewise property). A maximum a posteriori probability framework was developed to estimate the bias field contribution from a given CBCT image. The performance of the proposed CBCT image enhancement method was tested using phantoms and clinical CBCT images. Compared to the original CBCT images, the corrected images using the proposed method achieved a more uniform intensity distribution within each tissue type and significantly reduced cupping and shading artifacts. In a head and a pelvic case, the proposed method reduced the Hounsfield unit (HU) errors within the region of interest from 300 HU to less than 60 HU. In a chest case, the HU errors were reduced from 460 HU to less than 110 HU. The proposed CBCT image enhancement algorithm demonstrated a promising result by the reduction of the scatter-induced low-frequency image artifacts commonly encountered in kV CBCT imaging.

  9. A reconstruction algorithm for coherent scatter computed tomography based on filtered back-projection

    International Nuclear Information System (INIS)

    Stevendaal, U. van; Schlomka, J.-P.; Harding, A.; Grass, M.

    2003-01-01

    Coherent scatter computed tomography (CSCT) is a reconstructive x-ray imaging technique that yields the spatially resolved coherent-scatter form factor of the investigated object. Reconstruction from coherently scattered x-rays is commonly done using algebraic reconstruction techniques (ART). In this paper, we propose an alternative approach based on filtered back-projection. For the first time, a three-dimensional (3D) filtered back-projection technique using curved 3D back-projection lines is applied to two-dimensional coherent scatter projection data. The proposed algorithm is tested with simulated projection data as well as with projection data acquired with a demonstrator setup similar to a multi-line CT scanner geometry. While yielding comparable image quality as ART reconstruction, the modified 3D filtered back-projection algorithm is about two orders of magnitude faster. In contrast to iterative reconstruction schemes, it has the advantage that subfield-of-view reconstruction becomes feasible. This allows a selective reconstruction of the coherent-scatter form factor for a region of interest. The proposed modified 3D filtered back-projection algorithm is a powerful reconstruction technique to be implemented in a CSCT scanning system. This method gives coherent scatter CT the potential of becoming a competitive modality for medical imaging or nondestructive testing

  10. Classification of temporal bone pneumatization based on sigmoid sinus using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Han, S.-J. [Department of Otorhinolaryngology, National Health Insurance Corporation Ilsan Hospital, Seoul (Korea, Republic of); Song, M.H. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of); Kim, J. [Department of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, W.-S. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of); Lee, H.-K. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of)], E-mail: hoki@yuhs.ac

    2007-11-15

    Aim: To analyse several reference structures using axial computed tomography (CT) imaging of the temporal bone, which may reflect pneumatization of the entire temporal bone by statistical correlation to the actual volume of the temporal bone measured using three-dimensional reconstruction. Materials and methods: One hundred and sixteen temporal bones were studied, comprising 48 with normal findings and 68 sides showing chronic otitis media or temporal bone fracture. After measuring the volume of temporal bone air cells by the volume rendering technique using three-dimensional reconstruction images, classification of temporal bone pneumatization was performed using various reference structures on axial images to determine whether significant differences in the volume of temporal bone air cells could be found between the groups. Results: When the sigmoid sinus at the level of the malleoincudal complex was used in the classification, there were statistically significant differences between the groups that correlated with the entire volume of the temporal bone. Grouping based on the labyrinth and the ascending carotid artery showed insignificant differences in volume. Furthermore, there was no significant correlation between the cross-sectional area of the antrum and the entire volume of the temporal bone. Conclusion: The degree of pneumatization of temporal bone can be estimated easily by the evaluation of the air cells around the sigmoid sinus on axial CT images.

  11. Block matching sparsity regularization-based image reconstruction for incomplete projection data in computed tomography

    Science.gov (United States)

    Cai, Ailong; Li, Lei; Zheng, Zhizhong; Zhang, Hanming; Wang, Linyuan; Hu, Guoen; Yan, Bin

    2018-02-01

    In medical imaging many conventional regularization methods, such as total variation or total generalized variation, impose strong prior assumptions which can only account for very limited classes of images. A more reasonable sparse representation frame for images is still badly needed. Visually understandable images contain meaningful patterns, and combinations or collections of these patterns can be utilized to form some sparse and redundant representations which promise to facilitate image reconstructions. In this work, we propose and study block matching sparsity regularization (BMSR) and devise an optimization program using BMSR for computed tomography (CT) image reconstruction for an incomplete projection set. The program is built as a constrained optimization, minimizing the L1-norm of the coefficients of the image in the transformed domain subject to data observation and positivity of the image itself. To solve the program efficiently, a practical method based on the proximal point algorithm is developed and analyzed. In order to accelerate the convergence rate, a practical strategy for tuning the BMSR parameter is proposed and applied. The experimental results for various settings, including real CT scanning, have verified the proposed reconstruction method showing promising capabilities over conventional regularization.

  12. Geometrical analysis of woven fabric microstructure based on micron-resolution computed tomography data

    Science.gov (United States)

    Krieger, Helga; Seide, Gunnar; Gries, Thomas; Stapleton, Scott E.

    2018-04-01

    The global mechanical properties of textiles such as elasticity and strength, as well as transport properties such as permeability depend strongly on the microstructure of the textile. Textiles are heterogeneous structures with highly anisotropic material properties, including local fiber orientation and local fiber volume fraction. In this paper, an algorithm is presented to generate a virtual 3D-model of a woven fabric architecture with information about the local fiber orientation and the local fiber volume fraction. The geometric data of the woven fabric impregnated with resin was obtained by micron-resolution computed tomography (μCT). The volumetric μCT-scan was discretized into cells and the microstructure of each cell was analyzed and homogenized. Furthermore, the discretized data was used to calculate the local permeability tensors of each cell. An example application of the analyzed data is the simulation of the resin flow through a woven fabric based on the determined local permeability tensors and on Darcy's law. The presented algorithm is an automated and robust method of going from μCT-scans to structural or flow models.

  13. The bases for the use of interpolation in helical computed tomography: an explanation for radiologists

    International Nuclear Information System (INIS)

    Garcia-Santos, J. M.; Cejudo, J.

    2002-01-01

    In contrast to conventional computed tomography (CT), helical CT requires the application of interpolators to achieve image reconstruction. This is because the projections processed by the computer are not situated in the same plane. Since the introduction of helical CT. a number of interpolators have been designed in the attempt to maintain the thickness of the reconstructed section as close as possible to the thickness of the X-ray beam. The purpose of this article is to discuss the function of these interpolators, stressing the advantages and considering the possible inconveniences of high-grade curved interpolators with respect to standard linear interpolators. (Author) 7 refs

  14. Physics Model-Based Scatter Correction in Multi-Source Interior Computed Tomography.

    Science.gov (United States)

    Gong, Hao; Li, Bin; Jia, Xun; Cao, Guohua

    2018-02-01

    Multi-source interior computed tomography (CT) has a great potential to provide ultra-fast and organ-oriented imaging at low radiation dose. However, X-ray cross scattering from multiple simultaneously activated X-ray imaging chains compromises imaging quality. Previously, we published two hardware-based scatter correction methods for multi-source interior CT. Here, we propose a software-based scatter correction method, with the benefit of no need for hardware modifications. The new method is based on a physics model and an iterative framework. The physics model was derived analytically, and was used to calculate X-ray scattering signals in both forward direction and cross directions in multi-source interior CT. The physics model was integrated to an iterative scatter correction framework to reduce scatter artifacts. The method was applied to phantom data from both Monte Carlo simulations and physical experimentation that were designed to emulate the image acquisition in a multi-source interior CT architecture recently proposed by our team. The proposed scatter correction method reduced scatter artifacts significantly, even with only one iteration. Within a few iterations, the reconstructed images fast converged toward the "scatter-free" reference images. After applying the scatter correction method, the maximum CT number error at the region-of-interests (ROIs) was reduced to 46 HU in numerical phantom dataset and 48 HU in physical phantom dataset respectively, and the contrast-noise-ratio at those ROIs increased by up to 44.3% and up to 19.7%, respectively. The proposed physics model-based iterative scatter correction method could be useful for scatter correction in dual-source or multi-source CT.

  15. A novel forward projection-based metal artifact reduction method for flat-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Prell, Daniel; Kyriakou, Yiannis; Beister, Marcel; Kalender, Willi A [Institute of Medical Physics, University of Erlangen-Nuernberg, Henkestrasse 91, 91052 Erlangen (Germany)], E-mail: daniel.prell@imp.uni-erlangen.de

    2009-11-07

    Metallic implants generate streak-like artifacts in flat-detector computed tomography (FD-CT) reconstructed volumetric images. This study presents a novel method for reducing these disturbing artifacts by inserting discarded information into the original rawdata using a three-step correction procedure and working directly with each detector element. Computation times are minimized by completely implementing the correction process on graphics processing units (GPUs). First, the original volume is corrected using a three-dimensional interpolation scheme in the rawdata domain, followed by a second reconstruction. This metal artifact-reduced volume is then segmented into three materials, i.e. air, soft-tissue and bone, using a threshold-based algorithm. Subsequently, a forward projection of the obtained tissue-class model substitutes the missing or corrupted attenuation values directly for each flat detector element that contains attenuation values corresponding to metal parts, followed by a final reconstruction. Experiments using tissue-equivalent phantoms showed a significant reduction of metal artifacts (deviations of CT values after correction compared to measurements without metallic inserts reduced typically to below 20 HU, differences in image noise to below 5 HU) caused by the implants and no significant resolution losses even in areas close to the inserts. To cover a variety of different cases, cadaver measurements and clinical images in the knee, head and spine region were used to investigate the effectiveness and applicability of our method. A comparison to a three-dimensional interpolation correction showed that the new approach outperformed interpolation schemes. Correction times are minimized, and initial and corrected images are made available at almost the same time (12.7 s for the initial reconstruction, 46.2 s for the final corrected image compared to 114.1 s and 355.1 s on central processing units (CPUs))

  16. A novel forward projection-based metal artifact reduction method for flat-detector computed tomography

    International Nuclear Information System (INIS)

    Prell, Daniel; Kyriakou, Yiannis; Beister, Marcel; Kalender, Willi A

    2009-01-01

    Metallic implants generate streak-like artifacts in flat-detector computed tomography (FD-CT) reconstructed volumetric images. This study presents a novel method for reducing these disturbing artifacts by inserting discarded information into the original rawdata using a three-step correction procedure and working directly with each detector element. Computation times are minimized by completely implementing the correction process on graphics processing units (GPUs). First, the original volume is corrected using a three-dimensional interpolation scheme in the rawdata domain, followed by a second reconstruction. This metal artifact-reduced volume is then segmented into three materials, i.e. air, soft-tissue and bone, using a threshold-based algorithm. Subsequently, a forward projection of the obtained tissue-class model substitutes the missing or corrupted attenuation values directly for each flat detector element that contains attenuation values corresponding to metal parts, followed by a final reconstruction. Experiments using tissue-equivalent phantoms showed a significant reduction of metal artifacts (deviations of CT values after correction compared to measurements without metallic inserts reduced typically to below 20 HU, differences in image noise to below 5 HU) caused by the implants and no significant resolution losses even in areas close to the inserts. To cover a variety of different cases, cadaver measurements and clinical images in the knee, head and spine region were used to investigate the effectiveness and applicability of our method. A comparison to a three-dimensional interpolation correction showed that the new approach outperformed interpolation schemes. Correction times are minimized, and initial and corrected images are made available at almost the same time (12.7 s for the initial reconstruction, 46.2 s for the final corrected image compared to 114.1 s and 355.1 s on central processing units (CPUs)).

  17. Diversity of respiratory impedance based on quantitative computed tomography in patients with COPD.

    Science.gov (United States)

    Wada, Yosuke; Kitaguchi, Yoshiaki; Yasuo, Masanori; Ueno, Fumika; Kawakami, Satoshi; Fukushima, Kiyoyasu; Fujimoto, Keisaku; Hanaoka, Masayuki

    2018-01-01

    This study was conducted in order to investigate the diversity of respiratory physiology, including the respiratory impedance and reversibility of airway obstruction, based on quantitative computed tomography (CT) in patients with COPD. Medical records of 174 stable COPD patients were retrospectively reviewed to obtain the patients' clinical data, including the pulmonary function and imaging data. According to the software-based quantification of the degree of emphysema and airway wall thickness, the patients were classified into the "normal by CT" phenotype, the airway-dominant phenotype, the emphysema-dominant phenotype, and the mixed phenotype. The pulmonary function, including the respiratory impedance evaluated by using the forced oscillation technique (FOT) and the reversibility of airway obstruction in response to inhaled short-acting β 2 -agonists, was then compared among the four phenotypes. The respiratory system resistance at 5 and 20 Hz (R5 and R20) was significantly higher, and the respiratory system reactance at 5 Hz (X5) was significantly more negative in the airway-dominant and mixed phenotypes than in the other phenotypes. The within-breath changes of X5 (ΔX5) were significantly greater in the mixed phenotype than in the "normal by CT" and emphysema-dominant phenotypes. The FOT parameters (R5, R20, and X5) were significantly correlated with indices of the degree of airway wall thickness and significantly but weakly correlated with the reversibility of airway obstruction. There was no significant correlation between the FOT parameters (R5, R20, and X5) and the degree of emphysema. There is a diversity of respiratory physiology, including the respiratory impedance and reversibility of airway obstruction, based on quantitative CT in patients with COPD. The FOT measurements may reflect the degree of airway disease and aid in detecting airway remodeling in patients with COPD.

  18. MRI-Based Computed Tomography Metal Artifact Correction Method for Improving Proton Range Calculation Accuracy

    International Nuclear Information System (INIS)

    Park, Peter C.; Schreibmann, Eduard; Roper, Justin; Elder, Eric; Crocker, Ian; Fox, Tim; Zhu, X. Ronald; Dong, Lei; Dhabaan, Anees

    2015-01-01

    Purpose: Computed tomography (CT) artifacts can severely degrade dose calculation accuracy in proton therapy. Prompted by the recently increased popularity of magnetic resonance imaging (MRI) in the radiation therapy clinic, we developed an MRI-based CT artifact correction method for improving the accuracy of proton range calculations. Methods and Materials: The proposed method replaces corrupted CT data by mapping CT Hounsfield units (HU number) from a nearby artifact-free slice, using a coregistered MRI. MRI and CT volumetric images were registered with use of 3-dimensional (3D) deformable image registration (DIR). The registration was fine-tuned on a slice-by-slice basis by using 2D DIR. Based on the intensity of paired MRI pixel values and HU from an artifact-free slice, we performed a comprehensive analysis to predict the correct HU for the corrupted region. For a proof-of-concept validation, metal artifacts were simulated on a reference data set. Proton range was calculated using reference, artifactual, and corrected images to quantify the reduction in proton range error. The correction method was applied to 4 unique clinical cases. Results: The correction method resulted in substantial artifact reduction, both quantitatively and qualitatively. On respective simulated brain and head and neck CT images, the mean error was reduced from 495 and 370 HU to 108 and 92 HU after correction. Correspondingly, the absolute mean proton range errors of 2.4 cm and 1.7 cm were reduced to less than 2 mm in both cases. Conclusions: Our MRI-based CT artifact correction method can improve CT image quality and proton range calculation accuracy for patients with severe CT artifacts

  19. Quantitative image analysis of vertebral body architecture - improved diagnosis in osteoporosis based on high-resolution computed tomography

    International Nuclear Information System (INIS)

    Mundinger, A.; Wiesmeier, B.; Dinkel, E.; Helwig, A.; Beck, A.; Schulte Moenting, J.

    1993-01-01

    71 women, 64 post-menopausal, were examined by single-energy quantitative computed tomography (SEQCT) and by high-resolution computed tomography (HRCT) scans through the middle of lumbar vertebral bodies. Computer-assisted image analysis of the high-resolution images assessed trabecular morphometry of the vertebral spongiosa texture. Texture parameters differed in women with and without age-reduced bone density, and in the former group also in patients with and without vertebral fractures. Discriminating parameters were the total number, diameter and variance of trabecular and intertrabecular spaces as well as the trabecular surface (p < 0.05)). A texture index based on these statistically selected morphometric parameters identified a subgroup of patients suffering from fractures due to abnormal spongiosal architecture but with a bone mineral content not indicative for increased fracture risk. The combination of osteodensitometric and trabecular morphometry improves the diagnosis of osteoporosis and may contribute to the prediction of individual fracture risk. (author)

  20. Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy.

    Science.gov (United States)

    Yamamoto, Shingo; Tanooka, Masao; Ando, Kumiko; Yamano, Toshiko; Ishikura, Reiichi; Nojima, Michio; Hirota, Shozo; Shima, Hiroki

    2009-12-01

    To evaluate the diagnostic accuracy of computed tomography (CT)-based imaging methods for assessing renal vascular anatomy, imaging studies, including standard axial CT, three-dimensional volume-rendered CT (3DVR-CT), and a 3DVR-CT movie, were performed on 30 patients who underwent laparoscopic donor nephrectomy (10 right side, 20 left side) for predicting the location of the renal arteries and renal, adrenal, gonadal, and lumbar veins. These findings were compared with videos obtained during the operation. Two of 37 renal arteries observed intraoperatively were missed by standard axial CT and 3DVR-CT, whereas all arteries were identified by the 3DVR-CT movie. Two of 36 renal veins were missed by standard axial CT and 3DVR-CT, whereas 1 was missed by the 3DVR-CT movie. In 20 left renal hilar anatomical structures, 20 adrenal, 20 gonadal, and 22 lumbar veins were observed during the operation. Preoperatively, the standard axial CT, 3DVR-CT, and 3DVR-CT movie detected 11, 19, and 20 adrenal veins; 13, 14, and 19 gonadal veins; and 6, 11, and 15 lumbar veins, respectively. Overall, of 135 renal vascular structures, the standard axial CT, 3DVR-CT, and 3DVR-CT movie accurately detected 99 (73.3%), 113 (83.7%), and 126 (93.3%) vessels, respectively, which indicated that the 3DVR-CT movie demonstrated a significantly higher detection rate than other CT-based imaging methods (P renal vascular anatomy before laparoscopic donor nephrectomy.

  1. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  2. ℓ0 Gradient Minimization Based Image Reconstruction for Limited-Angle Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Wei Yu

    Full Text Available In medical and industrial applications of computed tomography (CT imaging, limited by the scanning environment and the risk of excessive X-ray radiation exposure imposed to the patients, reconstructing high quality CT images from limited projection data has become a hot topic. X-ray imaging in limited scanning angular range is an effective imaging modality to reduce the radiation dose to the patients. As the projection data available in this modality are incomplete, limited-angle CT image reconstruction is actually an ill-posed inverse problem. To solve the problem, image reconstructed by conventional filtered back projection (FBP algorithm frequently results in conspicuous streak artifacts and gradual changed artifacts nearby edges. Image reconstruction based on total variation minimization (TVM can significantly reduce streak artifacts in few-view CT, but it suffers from the gradual changed artifacts nearby edges in limited-angle CT. To suppress this kind of artifacts, we develop an image reconstruction algorithm based on ℓ0 gradient minimization for limited-angle CT in this paper. The ℓ0-norm of the image gradient is taken as the regularization function in the framework of developed reconstruction model. We transformed the optimization problem into a few optimization sub-problems and then, solved these sub-problems in the manner of alternating iteration. Numerical experiments are performed to validate the efficiency and the feasibility of the developed algorithm. From the statistical analysis results of the performance evaluations peak signal-to-noise ratio (PSNR and normalized root mean square distance (NRMSD, it shows that there are significant statistical differences between different algorithms from different scanning angular ranges (p<0.0001. From the experimental results, it also indicates that the developed algorithm outperforms classical reconstruction algorithms in suppressing the streak artifacts and the gradual changed

  3. Atlas-based delineation of lymph node levels in head and neck computed tomography images

    International Nuclear Information System (INIS)

    Commowick, Olivier; Gregoire, Vincent; Malandain, Gregoire

    2008-01-01

    Purpose: Radiotherapy planning requires accurate delineations of the tumor and of the critical structures. Atlas-based segmentation has been shown to be very efficient to automatically delineate brain critical structures. We therefore propose to construct an anatomical atlas of the head and neck region. Methods and materials: Due to the high anatomical variability of this region, an atlas built from a single image as for the brain is not adequate. We address this issue by building a symmetric atlas from a database of manually segmented images. First, we develop an atlas construction method and apply it to a database of 45 Computed Tomography (CT) images from patients with node-negative pharyngo-laryngeal squamous cell carcinoma manually delineated for radiotherapy. Then, we qualitatively and quantitatively evaluate the results generated by the built atlas based on Leave-One-Out framework on the database. Results: We present qualitative and quantitative results using this atlas construction method. The evaluation was performed on a subset of 12 patients among the original CT database of 45 patients. Qualitative results depict visually well delineated structures. The quantitative results are also good, with an error with respect to the best achievable results ranging from 0.196 to 0.404 with a mean of 0.253. Conclusions: These results show the feasibility of using such an atlas for radiotherapy planning. Many perspectives are raised from this work ranging from extensive validation to the construction of several atlases representing sub-populations, to account for large inter-patient variabilities, and populations with node-positive tumors

  4. Image-based metal artifact reduction in x-ray computed tomography utilizing local anatomical similarity

    Science.gov (United States)

    Dong, Xue; Yang, Xiaofeng; Rosenfield, Jonathan; Elder, Eric; Dhabaan, Anees

    2017-03-01

    X-ray computed tomography (CT) is widely used in radiation therapy treatment planning in recent years. However, metal implants such as dental fillings and hip prostheses can cause severe bright and dark streaking artifacts in reconstructed CT images. These artifacts decrease image contrast and degrade HU accuracy, leading to inaccuracies in target delineation and dose calculation. In this work, a metal artifact reduction method is proposed based on the intrinsic anatomical similarity between neighboring CT slices. Neighboring CT slices from the same patient exhibit similar anatomical features. Exploiting this anatomical similarity, a gamma map is calculated as a weighted summation of relative HU error and distance error for each pixel in an artifact-corrupted CT image relative to a neighboring, artifactfree image. The minimum value in the gamma map for each pixel is used to identify an appropriate pixel from the artifact-free CT slice to replace the corresponding artifact-corrupted pixel. With the proposed method, the mean CT HU error was reduced from 360 HU and 460 HU to 24 HU and 34 HU on head and pelvis CT images, respectively. Dose calculation accuracy also improved, as the dose difference was reduced from greater than 20% to less than 4%. Using 3%/3mm criteria, the gamma analysis failure rate was reduced from 23.25% to 0.02%. An image-based metal artifact reduction method is proposed that replaces corrupted image pixels with pixels from neighboring CT slices free of metal artifacts. This method is shown to be capable of suppressing streaking artifacts, thereby improving HU and dose calculation accuracy.

  5. Optimization-based scatter estimation using primary modulation for computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yi; Ma, Jingchen; Zhao, Jun, E-mail: junzhao@sjtu.edu.cn [School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Song, Ying [Department of Radiation Oncology, West China Hospital, Sichuan University, Chengdu 610041 (China)

    2016-08-15

    Purpose: Scatter reduces the image quality in computed tomography (CT), but scatter correction remains a challenge. A previously proposed primary modulation method simultaneously obtains the primary and scatter in a single scan. However, separating the scatter and primary in primary modulation is challenging because it is an underdetermined problem. In this study, an optimization-based scatter estimation (OSE) algorithm is proposed to estimate and correct scatter. Methods: In the concept of primary modulation, the primary is modulated, but the scatter remains smooth by inserting a modulator between the x-ray source and the object. In the proposed algorithm, an objective function is designed for separating the scatter and primary. Prior knowledge is incorporated in the optimization-based framework to improve the accuracy of the estimation: (1) the primary is always positive; (2) the primary is locally smooth and the scatter is smooth; (3) the location of penumbra can be determined; and (4) the scatter-contaminated data provide knowledge about which part is smooth. Results: The simulation study shows that the edge-preserving weighting in OSE improves the estimation accuracy near the object boundary. Simulation study also demonstrates that OSE outperforms the two existing primary modulation algorithms for most regions of interest in terms of the CT number accuracy and noise. The proposed method was tested on a clinical cone beam CT, demonstrating that OSE corrects the scatter even when the modulator is not accurately registered. Conclusions: The proposed OSE algorithm improves the robustness and accuracy in scatter estimation and correction. This method is promising for scatter correction of various kinds of x-ray imaging modalities, such as x-ray radiography, cone beam CT, and the fourth-generation CT.

  6. Assessment of skull base involvement in nasopharyngeal carcinoma: comparisons of single-photon emission tomography with planar bone scintigraphy and X-ray computed tomography

    International Nuclear Information System (INIS)

    Lee Chianghsuan; Wang Peiwen; Chen Hueyong; Lui Chunchung; Su Chihying

    1995-01-01

    The diagnostic contribution of single-photon emission tomography (SPET) to the detection of bone lesions of the skull base was explored in 200 patients with nasopharyngeal carcinoma (NPC). Comparison of SPET with planar bone scintigraphy showed that SPET improved the contrast and better defined the lesions in 107 out of the 200 patients. Comparison of SPET with X-ray computed tomography (CT) showed that SPET did not miss the lesions detected by CT while CT missed 49% of the lesions detected by SPET. The only false-positive lesion with SPET was detected in the mastoid bone. SPET detected skull base lesions in all of the 35 patients with cranial nerve involvement, while CT missed eight and planar bone scintigraphy missed four. The findings suggest that SPET should be included in the routine check-up examinations of patients with NPC. (orig.)

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ... ray beam follows a spiral path. A special computer program processes this large volume of data to ...

  12. Geometrical differences in target volumes based on 18F-fluorodeoxyglucose positron emission tomography/computed tomography and four-dimensional computed tomography maximum intensity projection images of primary thoracic esophageal cancer.

    Science.gov (United States)

    Guo, Y; Li, J; Wang, W; Zhang, Y; Wang, J; Duan, Y; Shang, D; Fu, Z

    2014-01-01

    The objective of the study was to compare geometrical differences of target volumes based on four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images of primary thoracic esophageal cancer for radiation treatment. Twenty-one patients with thoracic esophageal cancer sequentially underwent contrast-enhanced three-dimensional computed tomography (3DCT), 4DCT, and 18F-FDG PET/CT thoracic simulation scans during normal free breathing. The internal gross target volume defined as IGTVMIP was obtained by contouring on MIP images. The gross target volumes based on PET/CT images (GTVPET ) were determined with nine different standardized uptake value (SUV) thresholds and manual contouring: SUV≥2.0, 2.5, 3.0, 3.5 (SUVn); ≥20%, 25%, 30%, 35%, 40% of the maximum (percentages of SUVmax, SUVn%). The differences in volume ratio (VR), conformity index (CI), and degree of inclusion (DI) between IGTVMIP and GTVPET were investigated. The mean centroid distance between GTVPET and IGTVMIP ranged from 4.98 mm to 6.53 mm. The VR ranged from 0.37 to 1.34, being significantly (P<0.05) closest to 1 at SUV2.5 (0.94), SUV20% (1.07), or manual contouring (1.10). The mean CI ranged from 0.34 to 0.58, being significantly closest to 1 (P<0.05) at SUV2.0 (0.55), SUV2.5 (0.56), SUV20% (0.56), SUV25% (0.53), or manual contouring (0.58). The mean DI of GTVPET in IGTVMIP ranged from 0.61 to 0.91, and the mean DI of IGTVMIP in GTVPET ranged from 0.34 to 0.86. The SUV threshold setting of SUV2.5, SUV20% or manual contouring yields the best tumor VR and CI with internal-gross target volume contoured on MIP of 4DCT dataset, but 3DPET/CT and 4DCT MIP could not replace each other for motion encompassing target volume delineation for radiation treatment. © 2014 International Society for Diseases of the Esophagus.

  13. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  14. Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry

    Directory of Open Access Journals (Sweden)

    Timothy Olding

    2011-01-01

    Full Text Available This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparison to dose readout by magnetic resonance imaging (MRI. For example, only 60% of the voxels from an optical CT dose readout of a 1 l dosimeter passed a two-dimensional Low′s gamma test (at a 3%, 3 mm criteria, relative to a treatment plan for a well-characterized pencil beam delivery. When the same dosimeter was probed by MRI, a 93% pass rate was observed. The optical dose measurement was improved after modifications to the dosimeter preparation, matching its performance with the imaging capabilities of the scanner. With the new dosimeter preparation, 99.7% of the optical CT voxels passed a Low′s gamma test at the 3%, 3 mm criteria and 92.7% at a 2%, 2 mm criteria. The fitted interjar dose responses of a small sample set of modified dosimeters prepared (a from the same gel batch and (b from different gel batches prepared on the same day were found to be in agreement to within 3.6% and 3.8%, respectively, over the full dose range. Without drawing any statistical conclusions, this experiment gives a preliminary indication that intrabatch or interbatch NIPAM dosimeters prepared on the same day should be suitable for dose sensitivity calibration.

  15. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  16. Analysis of interfractional variations in pancreatic position based on four-dimensional computed tomography

    International Nuclear Information System (INIS)

    Shiinoki, Takehiro; Itoh, Akio; Shibuya, Keiko; Nakamura, Mitsuhiro; Nakamura, Akira; Matsuo, Yukinori; Sawada, Akira; Mizowaki, Takashi; Hiraoka, Masahiro

    2010-01-01

    The purpose of this study was to assess inter-fractional variations in pancreatic position using four-dimensional computed tomography (4D-CT) and to find the suitable phase of respiration for breath-holding. The variations in respiratory motion range during treatment course and inter-fractional variations in pancreatic positions were not negligible; however, our study suggested that breath-holding at end-exhalation with some coaching techniques might be considerable one of the non-invasive approaches to get higher positional reproducibility of pancreatic tumors. (author)

  17. Automated method for structural segmentation of nasal airways based on cone beam computed tomography

    Science.gov (United States)

    Tymkovych, Maksym Yu.; Avrunin, Oleg G.; Paliy, Victor G.; Filzow, Maksim; Gryshkov, Oleksandr; Glasmacher, Birgit; Omiotek, Zbigniew; DzierŻak, RóŻa; Smailova, Saule; Kozbekova, Ainur

    2017-08-01

    The work is dedicated to the segmentation problem of human nasal airways using Cone Beam Computed Tomography. During research, we propose a specialized approach of structured segmentation of nasal airways. That approach use spatial information, symmetrisation of the structures. The proposed stages can be used for construction a virtual three dimensional model of nasal airways and for production full-scale personalized atlases. During research we build the virtual model of nasal airways, which can be used for construction specialized medical atlases and aerodynamics researches.

  18. Bayesian Multi-Energy Computed Tomography reconstruction approaches based on decomposition models

    International Nuclear Information System (INIS)

    Cai, Caifang

    2013-01-01

    Multi-Energy Computed Tomography (MECT) makes it possible to get multiple fractions of basis materials without segmentation. In medical application, one is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical MECT measurements are usually obtained with polychromatic X-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam poly-chromaticity fail to estimate the correct decomposition fractions and result in Beam-Hardening Artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log pre-processing and the water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on non-linear forward models counting the beam poly-chromaticity show great potential for giving accurate fraction images.This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint Maximum A Posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a non-quadratic cost function. To solve it, the use of a monotone Conjugate Gradient (CG) algorithm with suboptimal descent steps is proposed.The performances of the proposed approach are analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also

  19. Computed tomography of cryogenic cells

    International Nuclear Information System (INIS)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-01-01

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions

  20. Radiomics-based differentiation of lung disease models generated by polluted air based on X-ray computed tomography data

    International Nuclear Information System (INIS)

    Szigeti, Krisztián; Szabó, Tibor; Korom, Csaba; Czibak, Ilona; Horváth, Ildikó; Veres, Dániel S.; Gyöngyi, Zoltán; Karlinger, Kinga; Bergmann, Ralf; Pócsik, Márta; Budán, Ferenc; Máthé, Domokos

    2016-01-01

    Lung diseases (resulting from air pollution) require a widely accessible method for risk estimation and early diagnosis to ensure proper and responsive treatment. Radiomics-based fractal dimension analysis of X-ray computed tomography attenuation patterns in chest voxels of mice exposed to different air polluting agents was performed to model early stages of disease and establish differential diagnosis. To model different types of air pollution, BALBc/ByJ mouse groups were exposed to cigarette smoke combined with ozone, sulphur dioxide gas and a control group was established. Two weeks after exposure, the frequency distributions of image voxel attenuation data were evaluated. Specific cut-off ranges were defined to group voxels by attenuation. Cut-off ranges were binarized and their spatial pattern was associated with calculated fractal dimension, then abstracted by the fractal dimension -- cut-off range mathematical function. Nonparametric Kruskal-Wallis (KW) and Mann–Whitney post hoc (MWph) tests were used. Each cut-off range versus fractal dimension function plot was found to contain two distinctive Gaussian curves. The ratios of the Gaussian curve parameters are considerably significant and are statistically distinguishable within the three exposure groups. A new radiomics evaluation method was established based on analysis of the fractal dimension of chest X-ray computed tomography data segments. The specific attenuation patterns calculated utilizing our method may diagnose and monitor certain lung diseases, such as chronic obstructive pulmonary disease (COPD), asthma, tuberculosis or lung carcinomas. The online version of this article (doi:10.1186/s12880-016-0118-z) contains supplementary material, which is available to authorized users

  1. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  2. A bent Laue-Laue monochromator for a synchrotron-based computed tomography system

    CERN Document Server

    Ren, B; Chapman, L D; Ivanov, I; Wu, X Y; Zhong, Z; Huang, X

    1999-01-01

    We designed and tested a two-crystal bent Laue-Laue monochromator for wide, fan-shaped synchrotron X-ray beams for the program multiple energy computed tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT employs monochromatic X-ray beams from the NSLS's X17B superconducting wiggler beamline for computed tomography (CT) with an improved image quality. MECT uses a fixed horizontal fan-shaped beam with the subject's apparatus rotating around a vertical axis. The new monochromator uses two Czochralski-grown Si crystals, 0.7 and 1.4 mm thick, respectively, and with thick ribs on their upper and lower ends. The crystals are bent cylindrically, with the axis of the cylinder parallel to the fan beam, using 4-rod benders with two fixed rods and two movable ones. The bent-crystal feature of the monochromator resolved the difficulties we had had with the flat Laue-Laue design previously used in MECT, which included (a) inadequate beam intensity, (b) excessive fluctuations in beam intensity, and (c) i...

  3. Emission computed tomography

    International Nuclear Information System (INIS)

    Phelps, M.E.

    1977-01-01

    Although there are many common aspects to x-ray transmission and radionuclide emission (ECT) computerized tomography, there are added difficulties and a number of particular factors which form the basis of ECT. The relationship between the physical factors, system design, methodologic approach and assumptions of ECT is discussed. The instrumentation design and application strategies in ECT at this time are diverse and in a rapid stage of development. The approaches are divided into two major categories of Single Photon Counting (SPC) employing scanner and camera concepts with radionuclides of 99 /sup m/Tc, 201 Tl, 123 I etc., and Annihilation Coincidence Detection (ACD) of positron-emitting radionuclides. Six systems in the former and ten systems in the latter category, with examples of typical studies, illustrate the different approaches

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... diagnose sinusitis . evaluate sinuses that are filled with fluid or thickened sinus membranes . detect the presence of ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... of the Sinuses? CT is usually the first test ordered when a sinus tumor is suspected. If ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... to reduce the risk of an allergic reaction. These medications must be taken 12 hours prior to ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to reduce the risk of an allergic reaction. These medications must be taken 12 hours prior to ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... to you, revolve around you during the imaging process. You will be alone in the exam room ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... cause blurring of the images and degrade the quality of the examination the same way that it ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... artifacts on the images. This loss of image quality can resemble the blurring seen on a photograph ...

  6. Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography.

    Science.gov (United States)

    Benz, Robyn Melanie; Garcia, Meritxell Alzamora; Amsler, Felix; Voigt, Johannes; Fieselmann, Andreas; Falkowski, Anna Lucja; Stieltjes, Bram; Hirschmann, Anna

    2018-01-01

    Phantom-based initial performance assessment of a prototype three-dimensional (3-D) x-ray system and comparison of 3-D tomography with computed tomography (CT) were proposed. A 3-D image quality phantom was scanned with a prototype version of 3-D cone-beam CT imaging implemented on a twin robotic x-ray system using three trajectories (163 deg = table, 188 deg = upright, and 200 deg = side), six tube voltages (60, 70, 81, 90, 100, and 121 kV), and four detector doses (0.348, 0.696, 1.740, and [Formula: see text]). CT was obtained with a clinical protocol. Spatial resolution (line pairs/cm) and soft-tissue-contrast resolution were assessed by two independent readers. Radiation dose was assessed. Descriptive and analysis of variance (ANOVA) ([Formula: see text]) were performed. With 3-D tomography, a maximum of 16 lp/cm was visible and best soft-tissue-contrast resolution was 2 mm at 30 Hounsfield units (HU) for 160 projections. With CT, 10 lp/cm was visible and soft-tissue-contrast resolution was 4 mm at 20 HU. The upright trajectory yielded significantly better spatial resolution and soft tissue contrast, and the side trajectory yielded significantly higher soft tissue contrast than the table trajectory ([Formula: see text]). Radiation dose was higher in 3-D tomography (45 to 704 mGycm) than CT (44 mGycm). Three-dimensional tomography renders overall equal or higher spatial resolution and comparable soft tissue contrast to CT for medium- and high-dose protocols in the side and upright trajectories, but with higher radiation doses.

  7. Community-Based Multidisciplinary Computed Tomography Screening Program Improves Lung Cancer Survival.

    Science.gov (United States)

    Miller, Daniel L; Mayfield, William R; Luu, Theresa D; Helms, Gerald A; Muster, Alan R; Beckler, Vickie J; Cann, Aaron

    2016-05-01

    Lung cancer is the most common cause of cancer deaths in the United States. Overall survival is less than 20%, with the majority of patients presenting with advanced disease. The National Lung Screening Trial, performed mainly in academic medical centers, showed that cancer mortality can be reduced with computed tomography (CT) screening compared with chest radiography in high-risk patients. To determine whether this survival advantage can be duplicated in a community-based multidisciplinary thoracic oncology program, we initiated a CT scan screening program for lung cancer within an established health care system. In 2008, we launched a lung cancer CT screening program within the WellStar Health System (WHS) consisting of five hospitals, three health parks, 140 outpatient medical offices, and 12 imaging centers that provide care in a five-county area of approximately 1.4 million people in Metro-Atlanta. Screening criteria incorporated were the International Early Lung Cancer Action Program (2008 to 2010) and National Comprehensive Cancer Network guidelines (2011 to 2013) for moderate- and high-risk patients. A total of 1,267 persons underwent CT lung cancer screening in WHS from 2008 through 2013; 53% were men, 87% were 50 years of age or older, and 83% were current or former smokers. Noncalcified indeterminate pulmonary nodules were found in 518 patients (41%). Thirty-six patients (2.8%) underwent a diagnostic procedure for positive findings on their CT scan; 30 proved to have cancer, 28 (2.2%) primary lung cancer and 2 metastatic cancer, and 6 had benign disease. Fourteen patients (50%) had their lung cancer discovered on their initial CT scan, 11 on subsequent scans associated with indeterminate pulmonary nodules growth and 3 patients who had a new indeterminate pulmonary nodules. Only 15 (54%) of these 28 patients would have qualified as a National Lung Screening Trial high-risk patient; 75% had stage I or II disease. Overall 5-year survival was 64% and 5-year

  8. A dental implant-based registration method for measuring mandibular kinematics using cone beam computed tomography-based fluoroscopy.

    Science.gov (United States)

    Lin, Cheng-Chung; Chen, Chien-Chih; Chen, Yunn-Jy; Lu, Tung-Wu; Hong, Shih-Wun

    2014-01-01

    This study aimed to develop and evaluate experimentally an implant-based registration method for measuring three-dimensional (3D) kinematics of the mandible and dental implants in the mandible based on dental cone beam computed tomography (CBCT), modified to include fluoroscopic function. The proposed implant-based registration method was based on the registration of CBCT data of implants/bones with single-plane fluoroscopy images. Seven registration conditions that included one to three implants were evaluated experimentally for their performance in a cadaveric porcine headmodel. The implant-based registration method was shown to have measurement errors (SD) of less than -0.2 (0.3) mm, 1.1 (2.2) mm, and 0.7 degrees (1.3 degrees) for the in-plane translation, out-of-plane translation, and all angular components, respectively, regardless of the number of implants used. The corresponding errors were reduced to less than -0.1 (0.1) mm, -0.3 (1.7) mm, and 0.5 degree (0.4 degree) when three implants were used. An implant-based registration method was developed to measure the 3D kinematics of the mandible/implants. With its high accuracy and reliability, the new method will be useful for measuring the 3D motion of the bones/implants for relevant applications.

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... information about radiation dose. There always is a risk of complications from general anesthesia or sedation. Every measure will be taken to ... in X-Ray and CT Exams Contrast Materials Anesthesia Safety Children and Radiation Safety ... (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) ...

  10. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  11. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  13. Laryngopyocele: signs on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nazaroglu, Hasan E-mail: hnazarog@dicle.edu.tr; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual.

  14. Laryngopyocele: signs on computed tomography

    International Nuclear Information System (INIS)

    Nazaroglu, Hasan; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual

  15. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  16. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  17. Positron computed tomography with fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Hervouet, T.; Kraeber-Bodere, F.; Lamy, T.; Le Gouil, S.; Devillers, A.; Bodet-Milin, C.; Ansquer, C.; Cheze-le Rest, C.; Metges, J.P.; Teyton, P.; Lozach, P.; Volant, A.; Bizais, Y.; Visvikis, D.; Morel, O.; Girault, S.; Soulie, P.; Dupoiron, D.; Berthelot, C.; Lorimier, G.; Jallet, P.; Garin, E.; Prigent, F.; Lesimple, T.; Barge, M.L.; Rousseau, C.; Devillers, A.; Bernard, A.M.; Bouriel, C.; Bridji, B.; Resche, R.; Banayan, S.; Claret, M.; Ninet, J.; Janier, M.; Billotey, C.; Garin, E.; Devillers, A.; Becker, S.; Lecloirec, J.; Boucher, E.; Raoul, J.L.; Rolland, V.; Oudoux, A.; Valette, F.; Dupas, B.; Moreau, P.; Champion, L.; Anract, P.; Wartski, M.; Laurence, V.; Goldwasser, F.; Pecking, A.P.; Alberini, J.L.; Brillouet, S.; Caselles, O.; Allal, B.; Zerdoud, S.; Gansel, M.G.; Thomas, F.; Dierrickx, L.; Delord, J.P.; Marchand, C.; Resche, I.; Mahe, M.A.

    2006-01-01

    Several oral communications present the interest of positron computed tomography with fluorodeoxyglucose in the detection of cancers, or for the follow up of cancers treatments in order to detect early possible relapses.PET FDG is also used to optimize the definition of target volume in order to avoid side effects and to get a better control of the illness. (N.C.)

  18. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  19. Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.

    Science.gov (United States)

    Roessl, Ewald; Brendel, Bernhard; Engel, Klaus-Jürgen; Schlomka, Jens-Peter; Thran, Axel; Proksa, Roland

    2011-09-01

    The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energy by using energy-sensitive, photon counting X-ray detectors. In this paper, we investigate the dependence of the sensitivity of K-edge imaging on the atomic number Z of the contrast material, on the object diameter D , on the spectral response of the X-ray detector and on the X-ray tube voltage. We assume a photon-counting detector equipped with six adjustable energy thresholds. Physical effects leading to a degradation of the energy resolution of the detector are taken into account using the concept of a spectral response function R(E,U) for which we assume four different models. As a validation of our analytical considerations and in order to investigate the influence of elliptically shaped phantoms, we provide CT simulations of an anthropomorphic Forbild-Abdomen phantom containing a gold-contrast agent. The dependence on the values of the energy thresholds is taken into account by optimizing the achievable signal-to-noise ratios (SNR) with respect to the threshold values. We find that for a given X-ray spectrum and object size the SNR in the heavy element's basis material image peaks for a certain atomic number Z. The dependence of the SNR in the high- Z basis-material image on the object diameter is the natural, exponential decrease with particularly deteriorating effects in the case where the attenuation from the object itself causes a total signal loss below the K-edge. The influence of the energy-response of the detector is very important. We observed that the optimal SNR values obtained with an ideal detector and with a CdTe pixel detector whose response, showing significant tailing, has been determined at a synchrotron differ by factors of

  20. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  1. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji [Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2015-03-15

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  2. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    International Nuclear Information System (INIS)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji

    2015-01-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  3. Development of indigenous USB based ICT-controller for industrial computed tomography scanner

    International Nuclear Information System (INIS)

    Walinjkar, Parag; Umesh Kumar

    2014-01-01

    In Industrial Computed Tomography (ICT) the quality of tomographic image depends on the accuracy of data/measurement. Isotope Production and Applications Division (IP and AD) is pioneer in this field and equipped with advance facility of ICT using gamma rays as well as X-rays. ICT-controller has been developed indigenously, for parallel beam scanning technique, to control scanning and data acquisition process automatically as per user requirements. The process of scanning and data collection has been automated using commercially available USB module. The acquired raw data is then processed and tomographic image of the specimen reconstructed to test operational performance of the ICT-controller. The paper is about the development of ICT-controller. It also describes the tests carried out to confirm successful development of the ICT-controller. (author)

  4. Feature-based analysis for quality assessment of x-ray computed tomography measurements

    International Nuclear Information System (INIS)

    Nardelli, Vitor C; Arenhart, Francisco A; Donatelli, Gustavo D; Porath, Maurício C; Niggemann, Christian; Schmitt, Robert

    2012-01-01

    This paper presents an approach to assess the quality of the data extracted with computed tomography (CT) measuring systems to perform geometrical evaluations. The approach consists in analyzing the error features introduced by the CT measuring system during the extraction operation. The analysis of the features is performed qualitatively (using graphical analysis tools) and/or quantitatively (by means of the root-mean-square deviation parameter of the error features). The approach was used to analyze four sets of measurements performed with an industrial x-ray cone beam CT measuring system. Three test parts were used in the experiments: a high accuracy manufacturing multi-wave standard, a calibrated step cylinder and a calibrated production part. The results demonstrate the usefulness of the approach to gain knowledge on CT measuring processes and improve the quality of CT geometrical evaluations. Advantages and limitations of the approach are discussed. (paper)

  5. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Schom, C.; Engelke, W.; Kopka, L.; Fischer, U.; Grabbe, E.

    1996-01-01

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.) [de

  6. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  7. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches

    NARCIS (Netherlands)

    Nada, R.M.; Maal, T.J.J.; Breuning, K.H.; Berge, S.J.; Mostafa, Y.A.; Kuijpers-Jagtman, A.M.

    2011-01-01

    Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans.

  8. Industrial applications of computer tomography

    International Nuclear Information System (INIS)

    Sheng Kanglong; Qiang Yujun; Yang Fujia

    1992-01-01

    Industrial computer tomography (CT) and its application is a rapidly developing field of high technology. CT systems have been playing important roles in nondestructive testing (NDT) of products and equipment for a number of industries. Recently, the technique has advanced into the area of industrial process control, bringing even greater benefit to mankind. The basic principles and typical structure of an industrial CT system Descriptions are given of some successful CT systems for either NDT application or process control purposes

  9. Computed tomography of projectile injuries

    International Nuclear Information System (INIS)

    Jeffery, A.J.; Rutty, G.N.; Robinson, C.; Morgan, B.

    2008-01-01

    Computed tomography (CT) is a gold standard in clinical imaging but forensic professions have been slow to embrace radiological advances. Forensic applications of CT are now exponentially expanding, replacing other imaging methods. As post-mortem cross-sectional imaging increases, radiologists will fall under increasing pressure to interpret complex forensic cases involving both living and deceased patients. This review presents a wide variety of weapon and projectile types aiding interpretation of projectile injuries both in forensic and clinical practice

  10. Computed tomography in osteoid osteoma

    International Nuclear Information System (INIS)

    Vicens, J.L.; Aubspin, D.; Buchon, R.; Schoenenberger, P.; Flageat, J.

    1989-01-01

    Four cases of suspected osteoid osteoma were evaluated by computed tomography (CT). The role of CT was related, as a key diagnostic tool: radionuclide imaging is helpful in directing subsequent CT scans, which allows the study of complex anatomical sites (spine) or the analysis of atypical lesions (invisible nidus, sclerosis or lytic lesions, double nidus...). CT provides the surgeon with the exact location and extent of the lesion, and thus, CT may allow a more limited surgical resection of the involved bone [fr

  11. Comparison of Real-Time Intraoperative Ultrasound-Based Dosimetry With Postoperative Computed Tomography-Based Dosimetry for Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Shi Peipei; Liu Bingren; Gupta, Nilendu; Bahnson, Robert R.; Wang, Jian Z.

    2008-01-01

    Purpose: To evaluate whether real-time intraoperative ultrasound (US)-based dosimetry can replace conventional postoperative computed tomography (CT)-based dosimetry in prostate brachytherapy. Methods and Materials: Between December 2001 and November 2002, 82 patients underwent 103 Pd prostate brachytherapy. An interplant treatment planning system was used for real-time intraoperative transrectal US-guided treatment planning. The dose distribution was updated according to the estimated seed position to obtain the dose-volume histograms. Postoperative CT-based dosimetry was performed a few hours later using the Theraplan-Plus treatment planning system. The dosimetric parameters obtained from the two imaging modalities were compared. Results: The results of this study revealed correlations between the US- and CT-based dosimetry. However, large variations were found in the implant-quality parameters of the two modalities, including the doses covering 100%, 90%, and 80% of the prostate volume and prostate volumes covered by 100%, 150%, and 200% of the prescription dose. The mean relative difference was 38% and 16% for doses covering 100% and 90% of the prostate volume and 10% and 21% for prostate volumes covered by 100% and 150% of the prescription dose, respectively. The CT-based volume covered by 200% of the prescription dose was about 30% greater than the US-based one. Compared with CT-based dosimetry, US-based dosimetry significantly underestimated the dose to normal organs, especially for the rectum. The average US-based maximal dose and volume covered by 100% of the prescription dose for the rectum was 72 Gy and 0.01 cm 3 , respectively, much lower than the 159 Gy and 0.65 cm 3 obtained using CT-based dosimetry. Conclusion: Although dosimetry using intraoperative US-based planning provides preliminary real-time information, it does not accurately reflect the postoperative CT-based dosimetry. Until studies have determined whether US-based dosimetry or

  12. Towards optical computed tomography

    International Nuclear Information System (INIS)

    Bones, P.J.; Packer, K.; Dainty, J.C.

    1996-01-01

    Advances in laser technology have sparked interest in the possibility of imaging within tissue with light. Acknowledging the self evident fact that most tissue is at best translucent and at worst relatively opaque, such 'imaging' is unlikely to be straightforward. Attention has therefore centred on exploiting some specific characteristics of last light. Simulations were performed (at Imperial College) to study the propagation of light from continuous and pulsed sources through very simple one- and two-dimensional piecewise homogeneous regions. A finite element method (FEM) package (developed for studying shielding from neutron penetration in nuclear energy systems) was employed along with Monte Carlo (MC) programs. A range of different scattering and absorption properties were modelled in the regions. Some simulation results were verified by statistical reasoning and/or analytical derivation based on transport theory. Poster 174. (author)

  13. 2-D Low Energy Electron Beam Profile Measurement Based on Computer Tomography Algorithm with Multi-Wire Scanner

    CERN Document Server

    Yu, Nengjie; Li Qing Feng; Tang, Chuan-Xiang; Zheng, Shuxin

    2005-01-01

    A new method for low energy electron beam profile measurement is advanced, which presents a full 2-D beam profile distribution other than the traditional 2-D beam profile distribution given by 1-D vertical and horizontal beam profiles. The method is based on the CT (Computer Tomography) algorithm. Multi-sets of data about the 1-D beam profile projections are attained by rotating the multi-wire scanner. Then a 2-D beam profile is reconstructed from these projections with CT algorithm. The principle of this method is presented. The simulation and the experiment results are compared and analyzed in detail.

  14. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  15. Computed tomography of the ossicles

    International Nuclear Information System (INIS)

    Chakeres, D.W.; Weider, D.J.

    1985-01-01

    Otologists and otolaryngologists have described in detail the disorders which are unique to the ossicles. However the anatomy and spectrum of pathology and anatomy of the ossicles are not familiar to most radiologists. Recent advances in computed tomography (CT) and a systematic approach to evaluation now allow accurate identification of even subtle abnormalities of the ossicles. We present the normal anatomy, ossicular abnormalities, and indications for computed tomographic study. Because of the greater diagnostic capability of CT, the radiologist's role has increased in evaluation and treatment planning of patients with suspected ossicular abnormalities. (orig.)

  16. Recent Developments in Computed Tomography

    International Nuclear Information System (INIS)

    Braunstein, D.; Dafni, E.; Levene, S.; Malamud, G.; Shapiro, O.; Shechter, G.; Zahavi, O.

    1999-01-01

    Computerized Tomography. has become, during the past few years, one of the mostly used apparatus in X-ray diagnosis. Its clinical applications has penetrated to various fields, like operational guidance, cardiac imaging, computer aided surgery etc. The first second-generation CT scanners consisted of a rotate-rotate system detectors array and an X-ray tube. These scanners were capable of acquiring individual single slices, the duration of each being several seconds. The slow scanning rate, and the then poor computers power, limited the application range of these scanners, to relatively stable organs, short body coverage at given resolutions. Further drawbacks of these machines were weak X-ray sources and low efficiency gas detectors. In the late 80's the first helical scanners were introduced by Siemens. Based on a continuous patient couch movement during gantry rotation, much faster scans could be obtained, increasing significantly the volume coverage at a given time. In 1992 the first dual-slice scanners, equipped with high efficiency solid state detectors were introduced by Elscint. The acquisition of data simultaneously from two detector arrays doubled the efficiency of the scan. Faster computers and stronger X-ray sources further improved the performance, allowing for a new range of clinical applications. Yet, the need for even faster machines and bigger volume coverage led to further R and D efforts by the leading CT manufacturers. In order to accomplish the most demanding clinical needs, innovative 2 dimensional 4-rows solid-state detector arrays were developed, together with faster rotating machines and bigger X-ray tubes, all demanding extremely accurate and robust mechanical constructions. Parallel, multi-processor custom computers were made, in order to allow the on-line reconstruction of the growing amounts of raw data. Four-slice helical scanners, rotating at 0.5 sec per cycle are being tested nowadays in several clinics all over the world. This talk

  17. Chest computed tomography-based scoring of thoracic sarcoidosis: Inter-rater reliability of CT abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Heuvel, D.A.V. den; Es, H.W. van; Heesewijk, J.P. van; Spee, M. [St. Antonius Hospital Nieuwegein, Department of Radiology, Nieuwegein (Netherlands); Jong, P.A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Zanen, P.; Grutters, J.C. [University Medical Center Utrecht, Division Heart and Lungs, Utrecht (Netherlands); St. Antonius Hospital Nieuwegein, Center of Interstitial Lung Diseases, Department of Pulmonology, Nieuwegein (Netherlands)

    2015-09-15

    To determine inter-rater reliability of sarcoidosis-related computed tomography (CT) findings that can be used for scoring of thoracic sarcoidosis. CT images of 51 patients with sarcoidosis were scored by five chest radiologists for various abnormal CT findings (22 in total) encountered in thoracic sarcoidosis. Using intra-class correlation coefficient (ICC) analysis, inter-rater reliability was analysed and reported according to the Guidelines for Reporting Reliability and Agreement Studies (GRRAS) criteria. A pre-specified sub-analysis was performed to investigate the effect of training. Scoring was trained in a distinct set of 15 scans in which all abnormal CT findings were represented. Median age of the 51 patients (36 men, 70 %) was 43 years (range 26 - 64 years). All radiographic stages were present in this group. ICC ranged from 0.91 for honeycombing to 0.11 for nodular margin (sharp versus ill-defined). The ICC was above 0.60 in 13 of the 22 abnormal findings. Sub-analysis for the best-trained observers demonstrated an ICC improvement for all abnormal findings and values above 0.60 for 16 of the 22 abnormalities. In our cohort, reliability between raters was acceptable for 16 thoracic sarcoidosis-related abnormal CT findings. (orig.)

  18. Cranial computed tomography associated with development of functional dependence in a community-based elderly population

    International Nuclear Information System (INIS)

    Tsukishima, Eri; Shido, Koichi

    2002-01-01

    The purpose of this study was to investigate whether changes at computed tomography (CT) imaging in the ageing brain are associated with future risks for functional dependence. One hundred sixty residents aged 69 years and older at the cranial CT and were independently living in a rural community in Hokkaido, Japan. Cranial CT was performed between 1991 and 1993, graded for ventricular enlargement, sulcal enlargement, white matter change, and small infarction. Functional status was reassessed in 1998 in each participant. Multiple logistic regression analysis was performed to estimate the association of CT changes in the ageing brain with development of functional dependence over six years. Functional dependence was found in 19 residents at the second survey. After adjusting for age, sex, medical conditions, and cognitive functioning, small infarction and ventricular enlargement were significantly associated with development of functional dependence (adjusted odds ratio=9.27 and 4.62). After controlling for age, the age-related changes on cranial CT have significant association on development of functional dependence. (author)

  19. Finite element analysis of the mechanical properties of cellular aluminium based on micro-computed tomography

    International Nuclear Information System (INIS)

    Veyhl, C.; Belova, I.V.; Murch, G.E.; Fiedler, T.

    2011-01-01

    Research highlights: → Elastic and plastic anisotropy is observed for both materials → Both show qualitatively similar characteristics with quantitative differences → Distinctly higher mechanical properties for closed-cell foam → The 'big' and 'small' models show good agreement for the closed-cell foam. - Abstract: In the present paper, the macroscopic mechanical properties of open-cell M-Pore sponge (porosity of 91-93%) and closed-cell Alporas foam (porosity of 80-86%) are investigated. The complex geometry of these cellular materials is scanned by micro-computed tomography and used in finite element (FE) analysis. The mechanical properties are determined by uni-axial compression simulations in three perpendicular directions (x-, y- and z-direction). M-Pore and Alporas exhibit the same qualitative mechanical characteristics but with quantitative differences. In both cases, strong anisotropy is observed for Young's modulus and the 0.002 offset yield stress. Furthermore, for the investigated relative density range a linear dependence between relative density and mechanical properties is found. Finally, a distinctly higher Young's modulus and 0.002 offset yield stress is observed for Alporas.

  20. Isotropic-resolution linear-array-based photoacoustic computed tomography through inverse Radon transform

    Science.gov (United States)

    Li, Guo; Xia, Jun; Li, Lei; Wang, Lidai; Wang, Lihong V.

    2015-03-01

    Linear transducer arrays are readily available for ultrasonic detection in photoacoustic computed tomography. They offer low cost, hand-held convenience, and conventional ultrasonic imaging. However, the elevational resolution of linear transducer arrays, which is usually determined by the weak focus of the cylindrical acoustic lens, is about one order of magnitude worse than the in-plane axial and lateral spatial resolutions. Therefore, conventional linear scanning along the elevational direction cannot provide high-quality three-dimensional photoacoustic images due to the anisotropic spatial resolutions. Here we propose an innovative method to achieve isotropic resolutions for three-dimensional photoacoustic images through combined linear and rotational scanning. In each scan step, we first elevationally scan the linear transducer array, and then rotate the linear transducer array along its center in small steps, and scan again until 180 degrees have been covered. To reconstruct isotropic three-dimensional images from the multiple-directional scanning dataset, we use the standard inverse Radon transform originating from X-ray CT. We acquired a three-dimensional microsphere phantom image through the inverse Radon transform method and compared it with a single-elevational-scan three-dimensional image. The comparison shows that our method improves the elevational resolution by up to one order of magnitude, approaching the in-plane lateral-direction resolution. In vivo rat images were also acquired.

  1. Classification of spondylolysis in the growing period based on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yoshimitsu; Kono, Sachu; Nagano, Junji; Sugawa, Isao (Seirei Hamamatsu Hospital, Shizuoka (Japan))

    1989-11-01

    Serial computed tomography (CT) images of 104 vertebrae were reviewed from 103 sport men aged 18 or under, in whom spondylolysis was radiologically suspected during the period from January 1985 through August 1988. Twenty-four vertebrae (23%) showed false positive CT for spondylolysis. Findings of CT in 80 vertebrae were classified into four types according to the degree of spondylolysis and bone sclerosis, and marginal morphology of the dissolved vertebra. X-ray images in the oblique projection revealed infraction in 53%, 74%, and 9% for Types I, II, and III, respectively; and pseudoarthrosis in 24% and 91% for Types II and II, respectively. In Type I, X-ray failed to reveal spondylolysis in 36%, although it was capable of denying it in 11%. Early spondylolysis, as observed in Type I, was difficult to diagnose on plain X-ray. In Type III, X-ray proved to be helpful in diagnosing spondylolysis. Diversified X-ray appearances of spondylolysis seemed to be attributable to the degree of spondylolysis and irregular running of the dissolved vertebra. An adhesion rate of 41% could be achieved with conservative therapy alone for Type I. These results indicated that CT may be helpful in the classification of spondylolysis that is required for conservative treatment aimed at bone adhesion. (N.K.).

  2. Classification of spondylolysis in the growing period based on computed tomography

    International Nuclear Information System (INIS)

    Kobayashi, Yoshimitsu; Kono, Sachu; Nagano, Junji; Sugawa, Isao

    1989-01-01

    Serial computed tomography (CT) images of 104 vertebrae were reviewed from 103 sport men aged 18 or under, in whom spondylolysis was radiologically suspected during the period from January 1985 through August 1988. Twenty-four vertebrae (23%) showed false positive CT for spondylolysis. Findings of CT in 80 vertebrae were classified into four types according to the degree of spondylolysis and bone sclerosis, and marginal morphology of the dissolved vertebra. X-ray images in the oblique projection revealed infraction in 53%, 74%, and 9% for Types I, II, and III, respectively; and pseudoarthrosis in 24% and 91% for Types II and II, respectively. In Type I, X-ray failed to reveal spondylolysis in 36%, although it was capable of denying it in 11%. Early spondylolysis, as observed in Type I, was difficult to diagnose on plain X-ray. In Type III, X-ray proved to be helpful in diagnosing spondylolysis. Diversified X-ray appearances of spondylolysis seemed to be attributable to the degree of spondylolysis and irregular running of the dissolved vertebra. An adhesion rate of 41% could be achieved with conservative therapy alone for Type I. These results indicated that CT may be helpful in the classification of spondylolysis that is required for conservative treatment aimed at bone adhesion. (N.K.)

  3. Chest computed tomography-based scoring of thoracic sarcoidosis: Inter-rater reliability of CT abnormalities

    International Nuclear Information System (INIS)

    Heuvel, D.A.V. den; Es, H.W. van; Heesewijk, J.P. van; Spee, M.; Jong, P.A. de; Zanen, P.; Grutters, J.C.

    2015-01-01

    To determine inter-rater reliability of sarcoidosis-related computed tomography (CT) findings that can be used for scoring of thoracic sarcoidosis. CT images of 51 patients with sarcoidosis were scored by five chest radiologists for various abnormal CT findings (22 in total) encountered in thoracic sarcoidosis. Using intra-class correlation coefficient (ICC) analysis, inter-rater reliability was analysed and reported according to the Guidelines for Reporting Reliability and Agreement Studies (GRRAS) criteria. A pre-specified sub-analysis was performed to investigate the effect of training. Scoring was trained in a distinct set of 15 scans in which all abnormal CT findings were represented. Median age of the 51 patients (36 men, 70 %) was 43 years (range 26 - 64 years). All radiographic stages were present in this group. ICC ranged from 0.91 for honeycombing to 0.11 for nodular margin (sharp versus ill-defined). The ICC was above 0.60 in 13 of the 22 abnormal findings. Sub-analysis for the best-trained observers demonstrated an ICC improvement for all abnormal findings and values above 0.60 for 16 of the 22 abnormalities. In our cohort, reliability between raters was acceptable for 16 thoracic sarcoidosis-related abnormal CT findings. (orig.)

  4. Positron Emission Tomography/Computed Tomography Imaging of Residual Skull Base Chordoma Before Radiotherapy Using Fluoromisonidazole and Fluorodeoxyglucose: Potential Consequences for Dose Painting

    Energy Technology Data Exchange (ETDEWEB)

    Mammar, Hamid, E-mail: hamid.mammar@unice.fr [Radiation Oncology Department, Antoine Lacassagne Center, Nice (France); CNRS-UMR 6543, Institute of Developmental Biology and Cancer, University of Nice Sophia Antipolis, Nice (France); Kerrou, Khaldoun; Nataf, Valerie [Department of Nuclear Medicine and Radiopharmacy, Tenon Hospital, and University Pierre et Marie Curie, Paris (France); Pontvert, Dominique [Proton Therapy Center of Orsay, Curie Institute, Paris (France); Clemenceau, Stephane [Department of Neurosurgery, Pitie-Salpetriere Hospital, Paris (France); Lot, Guillaume [Department of Neurosurgery, Adolph De Rothschild Foundation, Paris (France); George, Bernard [Department of Neurosurgery, Lariboisiere Hospital, Paris (France); Polivka, Marc [Department of Pathology, Lariboisiere Hospital, Paris (France); Mokhtari, Karima [Department of Pathology, Pitie-Salpetriere Hospital, Paris (France); Ferrand, Regis; Feuvret, Loiec; Habrand, Jean-louis [Proton Therapy Center of Orsay, Curie Institute, Paris (France); Pouyssegur, Jacques; Mazure, Nathalie [CNRS-UMR 6543, Institute of Developmental Biology and Cancer, University of Nice Sophia Antipolis, Nice (France); Talbot, Jean-Noeel [Department of Nuclear Medicine and Radiopharmacy, Tenon Hospital, and University Pierre et Marie Curie, Paris (France)

    2012-11-01

    Purpose: To detect the presence of hypoxic tissue, which is known to increase the radioresistant phenotype, by its uptake of fluoromisonidazole (18F) (FMISO) using hybrid positron emission tomography/computed tomography (PET/CT) imaging, and to compare it with the glucose-avid tumor tissue imaged with fluorodeoxyglucose (18F) (FDG), in residual postsurgical skull base chordoma scheduled for radiotherapy. Patients and Methods: Seven patients with incompletely resected skull base chordomas were planned for high-dose radiotherapy (dose {>=}70 Gy). All 7 patients underwent FDG and FMISO PET/CT. Images were analyzed qualitatively by visual examination and semiquantitatively by computing the ratio of the maximal standardized uptake value (SUVmax) of the tumor and cerebellum (T/C R), with delineation of lesions on conventional imaging. Results: Of the eight lesion sites imaged with FDG PET/CT, only one was visible, whereas seven of nine lesions were visible on FMISO PET/CT. The median SUVmax in the tumor area was 2.8 g/mL (minimum 2.1; maximum 3.5) for FDG and 0.83 g/mL (minimum 0.3; maximum 1.2) for FMISO. The T/C R values ranged between 0.30 and 0.63 for FDG (median, 0.41) and between 0.75 and 2.20 for FMISO (median,1.59). FMISO T/C R >1 in six lesions suggested the presence of hypoxic tissue. There was no correlation between FMISO and FDG uptake in individual chordomas (r = 0.18, p = 0.7). Conclusion: FMISO PET/CT enables imaging of the hypoxic component in residual chordomas. In the future, it could help to better define boosted volumes for irradiation and to overcome the radioresistance of these lesions. No relationship was founded between hypoxia and glucose metabolism in these tumors after initial surgery.

  5. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  6. The history of computed tomography

    International Nuclear Information System (INIS)

    Bull, J.

    1980-01-01

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ) [de

  7. Computed tomography-based anatomic characterization of proximal aortic dissection with consideration for endovascular candidacy.

    Science.gov (United States)

    Moon, Michael C; Greenberg, Roy K; Morales, Jose P; Martin, Zenia; Lu, Qingsheng; Dowdall, Joseph F; Hernandez, Adrian V

    2011-04-01

    Proximal aortic dissections are life-threatening conditions that require immediate surgical intervention to avert an untreated mortality rate that approaches 50% at 48 hours. Advances in computed tomography (CT) imaging techniques have permitted increased characterization of aortic dissection that are necessary to assess the design and applicability of new treatment paradigms. All patients presenting during a 2-year period with acute proximal aortic dissections who underwent CT scanning were reviewed in an effort to establish a detailed assessment of their aortic anatomy. Imaging studies were assessed in an effort to document the location of the primary proximal fenestration, the proximal and distal extent of the dissection, and numerous morphologic measurements pertaining to the aortic valve, root, and ascending aorta to determine the potential for an endovascular exclusion of the ascending aorta. During the study period, 162 patients presented with proximal aortic dissections. Digital high-resolution preoperative CT imaging was performed on 76 patients, and 59 scans (77%) were of adequate quality to allow assessment of anatomic suitability for treatment with an endograft. In all cases, the dissection plane was detectable, yet the primary intimal fenestration was identified in only 41% of the studies. Scans showed 24 patients (32%) appeared to be anatomically amenable to such a repair (absence of valvular involvement, appropriate length and diameter of proximal sealing regions, lack of need to occlude coronary vasculature). Of the 42 scans that were determined not to be favorable for endovascular repair, the most common exclusion finding was the absence of a proximal landing zone (n = 15; 36%). Appropriately protocoled CT imaging provides detailed anatomic information about the aortic root and ascending aorta, allowing the assessment of which dissections have proximal fenestrations that may be amenable to an endovascular repair. Copyright © 2011 Society for

  8. Cemento-Osseous Dysplasias: Imaging Features Based on Cone Beam Computed Tomography Scans.

    Science.gov (United States)

    Cavalcanti, Paulo Henrique Pereira; Nascimento, Eduarda Helena Leandro; Pontual, Maria Luiza Dos Anjos; Pontual, Andréa Dos Anjos; Marcelos, Priscylla Gonçalves Correia Leite de; Perez, Danyel Elias da Cruz; Ramos-Perez, Flávia Maria de Moraes

    2018-01-01

    Imaging exams have important role in diagnosis of cemento-osseous dysplasia (COD). Cone beam computed tomography (CBCT) stands out for allowing three-dimensional image evaluation. This study aimed to assess the prevalence of cases diagnosed as COD on CBCT scans, as well identify the main imaging features related to these lesions. An analysis was performed in a database containing 22,400 radiological reports, in which all cases showing some type of COD were initially selected. These CBCT exams were reevaluated to confirm the radiographic diagnosis and determine the prevalence and distribution of the types of COD with regard to gender, age and preferred location, while describing its most common imaging aspects. Data were presented using descriptive analyses. There were 82 cases diagnosed as COD in the CBCT images (prevalence of 0.4%). The distribution of patients was 11 (13.4%) male and 71 (86.6%) female, with a mean age of 49.8 years (age-range 17-85 years). There were 47 (57.3%) cases of periapical COD, 23 (28%) of focal COD and 12 (14.6%) of florid COD. The mandible was more affected than the maxilla. In most cases, the lesions were mixed or hyperdense. All COD had well-defined limits and there were no cases of tooth displacement. In conclusion, periapical COD was the most common type and the most affected bone was the mandible. Imaging evaluation is critical for diagnosis and dentists should bear in mind all possible radiographic presentations of COD in order to prevent misleading diagnoses and consequently, inadequate treatments.

  9. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic. (orig.)

  10. Duodenal diverticulitis. computed tomography findings

    International Nuclear Information System (INIS)

    Sanchez, E.; Martin, S.; Garcia, J.; Dominguez, A.

    2001-01-01

    Duodenal diverticular occur very frequently among the general public. However, duodenal diverticulitis is a very uncommon clinical entity, the diagnosis of which requires radiological studies since the clinical signs cam mimic a great number of disease processes with different treatments. We present a case of duodenal diverticulitis in which the diagnosis according to ultrasound and computed tomography (CT) studies was confirmed intraoperatively. We also review the few cases of this entity reported in the literature. The CT findings are highly suggestive of duodenal diverticulitis given their similarity to those associated with diverticulitis at other sites. (Author) 5 refs,

  11. Mathematical foundations of computed tomography

    International Nuclear Information System (INIS)

    Smith, K.T.; Keinert, F.

    1985-01-01

    Along with a review of some of the mathematical foundations of computed tomography, the article contains new results on derivation of reconstruction formulas in a general setting encompassing all standard formulas; discussion and examples of the role of the point spread function with recipes for producing suitable ones; formulas for, and examples of, the reconstruction of certain functions of the attenuation coefficient, e.g., sharpened versions of it, some of them with the property that reconstruction at a point requires only the attenuation along rays meeting a small neighborhood of the point

  12. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  13. Brain metastases: computed tomography assessment

    International Nuclear Information System (INIS)

    Gordillo, Victoria; Yagual, Glenda; Vinueza, Clayreth

    1998-01-01

    Intracranial metastatic tumor is relatively frequent in patients with cancer from other origin. Its location and type of metastasis varies in relation to its linage from the primary tumor. And the sequence goes from the most frequent: lung and breast cancer, melanoma, GU tract, leukemia, GI tract, head and neck tumor. Computed tomography findings are extremely varied and non specific, so there are no radiologic characteristics even from the primary tumor. We reviewed 29 TC studies in the Radiology department of ION-SOLCA, from patients with diagnosis of brain metastasis, our findings showed the great variability in the radio-diagnosis imaging. (The author)

  14. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic

  15. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  16. Using high resolution X-ray computed tomography to create an image based model of a lymph node.

    Science.gov (United States)

    Cooper, L J; Zeller-Plumhoff, B; Clough, G F; Ganapathisubramani, B; Roose, T

    2018-07-14

    Lymph nodes are an important part of the immune system. They filter the lymphatic fluid as it is transported from the tissues before being returned to the blood stream. The fluid flow through the nodes influences the behaviour of the immune cells that gather within the nodes and the structure of the node itself. Measuring the fluid flow in lymph nodes experimentally is challenging due to their small size and fragility. In this paper, we present high resolution X-ray computed tomography images of a murine lymph node. The impact of the resulting visualized structures on fluid transport are investigated using an image based model. The high contrast between different structures within the lymph node provided by phase contrast X-ray computed tomography reconstruction results in images that, when related to the permeability of the lymph node tissue, suggest an increased fluid velocity through the interstitial channels in the lymph node tissue. Fluid taking a direct path from the afferent to the efferent lymphatic vessel, through the centre of the node, moved faster than the fluid that flowed around the periphery of the lymph node. This is a possible mechanism for particles being moved into the cortex. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  18. Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.

    Science.gov (United States)

    Meagher, Matthew J; Parwani, Rachna N; Virdi, Amarjit S; Sumner, Dale R

    2018-03-01

    Histology and backscatter scanning electron microscopy (bSEM) are the current gold standard methods for quantifying bone-implant contact (BIC), but are inherently destructive. Microcomputed tomography (μCT) is a non-destructive alternative, but attempts to validate μCT-based assessment of BIC in animal models have produced conflicting results. We previously showed in a rat model using a 1.5 mm diameter titanium implant that the extent of the metal-induced artefact precluded accurate measurement of bone sufficiently close to the interface to assess BIC. Recently introduced commercial laboratory μCT scanners have smaller voxels and improved imaging capabilities, possibly overcoming this limitation. The goals of the present study were to establish an approach for optimizing μCT imaging parameters and to validate μCT-based assessment of BIC. In an empirical parametric study using a 1.5 mm diameter titanium implant, we determined 90 kVp, 88 µA, 1.5 μm isotropic voxel size, 1600 projections/180°, and 750 ms integration time to be optimal. Using specimens from an in vivo rat experiment, we found significant correlations between bSEM and μCT for BIC with the manufacturer's automated analysis routine (r = 0.716, p = 0.003) or a line-intercept method (r = 0.797, p = 0.010). Thus, this newer generation scanner's improved imaging capability reduced the extent of the metal-induced artefact zone enough to permit assessment of BIC. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:979-986, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  19. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Isherwood, I.; Antoun, N.M.

    1984-01-01

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  20. Motion artifacts in computed tomography

    International Nuclear Information System (INIS)

    Yang, C.K.

    1979-01-01

    In the year 1972, the first Computed Tomography Scanner (or CT) was introduced and caused a revolution in the field of Diagnostic Radiology. A tomogram is a cross-sectional image of a three-dimensional object obtained through non-invasive measurements. The image that is presented is very similar to what would be seen if a thin cross-sectional slice of the patient was examined. In Computed Tomography, x-rays are passed through the body of a patient in many different directions and their attenuation is detected. By using some mathematical theorems, the attenuation information can be converted into the density of the patient along the x-ray path. Combined with modern sophisticated computer signal processing technology, a cross-sectional image can be generated and displayed on a TV monitor. Usually a good CT image relies on the patient not moving during the x-ray scanning. However, for some unconscious or severely ill patients, this is very difficult to achieve. Thus, the motion during the scan causes the so-called motion artifacts which distort the displayed image and sometimes these motion artifacts make diagnosis impossible. Today, to remove or avoid motion artifacts is one of the major efforts in developing new scanner systems. In this thesis, a better understanding of the motion artifacts problem in CT scaning is gained through computer simulations, real scanner experiments and theoretical analyses. The methods by which the distorted image can be improved are simulated also. In particular, it is assumed that perfect knowledge of the patient motion is known since this represents the theoretical limit on how well the distorted image can be improved

  1. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  2. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  3. Estimation of kidneys and urinary bladder doses based on the region of interest in 18fluorine-fluorodeoxyglucose positron emission tomography/computed tomography examination: a preliminary study.

    Science.gov (United States)

    Mustapha, Farida Aimi; Bashah, Farahnaz Ahmad Anwar; Yassin, Ihsan M; Fathinul Fikri, Ahmad Saad; Nordin, Abdul Jalil; Abdul Razak, Hairil Rashmizal

    2017-06-01

    Kidneys and urinary bladder are common physiologic uptake sites of 18fluorine-fluorodeoxyglucose ( 18 F-FDG) causing increased exposure of low energy ionizing radiation to these organs. Accurate measurement of organ dose is vital as 18 F-FDG is directly exposed to the organs. Organ dose from 18 F-FDG PET is calculated according to the injected 18 F-FDG activity with the application of dose coefficients established by International Commission on Radiological Protection (ICRP). But this dose calculation technique is not directly measured from these organs; rather it is calculated based on total injected activity of radiotracer prior to scanning. This study estimated the 18 F-FDG dose to the kidneys and urinary bladder in whole body positron emission tomography/computed tomography (PET/CT) examination by comparing dose from total injected activity of 18 F-FDG (calculated dose) and dose from organs activity based on the region of interest (ROI) (measured dose). Nine subjects were injected intravenously with the mean 18 F-FDG dose of 292.42 MBq prior to whole body PET/CT scanning. Kidneys and urinary bladder doses were estimated by using two approaches which are the total injected activity of 18 F-FDG and organs activity concentration of 18 F-FDG based on drawn ROI with the application of recommended dose coefficients for 18 F-FDG described in the ICRP 80 and ICRP 106. The mean percentage difference between calculated dose and measured dose ranged from 98.95% to 99.29% for the kidneys based on ICRP 80 and 98.96% to 99.32% based on ICRP 106. Whilst, the mean percentage difference between calculated dose and measured dose was 97.08% and 97.27% for urinary bladder based on ICRP 80 while 96.99% and 97.28% based on ICRP 106. Whereas, the range of mean percentage difference between calculated and measured organ doses derived from ICRP 106 and ICRP 80 for kidney doses were from 17.00% to 40.00% and for urinary bladder dose was 18.46% to 18.75%. There is a significant

  4. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  5. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  6. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  7. A simulation-based study on the influence of beam hardening in X-ray computed tomography for dimensional metrology.

    Science.gov (United States)

    Lifton, Joseph J; Malcolm, Andrew A; McBride, John W

    2015-01-01

    X-ray computed tomography (CT) is a radiographic scanning technique for visualising cross-sectional images of an object non-destructively. From these cross-sectional images it is possible to evaluate internal dimensional features of a workpiece which may otherwise be inaccessible to tactile and optical instruments. Beam hardening is a physical process that degrades the quality of CT images and has previously been suggested to influence dimensional measurements. Using a validated simulation tool, the influence of spectrum pre-filtration and beam hardening correction are evaluated for internal and external dimensional measurements. Beam hardening is shown to influence internal and external dimensions in opposition, and to have a greater influence on outer dimensions compared to inner dimensions. The results suggest the combination of spectrum pre-filtration and a local gradient-based surface determination method are able to greatly reduce the influence of beam hardening in X-ray CT for dimensional metrology.

  8. SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

    Energy Technology Data Exchange (ETDEWEB)

    Chacko, M; Aldoohan, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT

  9. Computed tomography of splenic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey, R.B.; Laing, F.C.; Federle, M.P.; Goodman, P.C.

    1981-12-01

    Fifty patients with abdominal trauma and possible splenic injury were evaluated by computed tomography (CT). CT correctly diagnosed 21 of 22 surgically proved traumatic sesions of the spleen (96%). Twenty-seven patients had no evidence of splenic injury. This was confirmed at operation in 1 patient and clinical follow-up in 26. There were one false negative and one false positive. In 5 patients (10%), CT demonstrated other clinically significant lesions, including hepatic or renal lacerations in 3 and large retroperitoneal hematomas in 2. In adolescents and adults, CT is an accurate, noninvasive method of rapidly diagnosing splenic trauma and associated injuries. Further experience is needed to assess its usefulness in evaluating splenic injuries in infants and small children.

  10. Computed tomography of splenic trauma

    International Nuclear Information System (INIS)

    Jeffrey, R.B.; Laing, F.C.; Federle, M.P.; Goodman, P.C.

    1981-01-01

    Fifty patients with abdominal trauma and possible splenic injury were evaluated by computed tomography (CT). CT correctly diagnosed 21 of 22 surgically proved traumatic sesions of the spleen (96%). Twenty-seven patients had no evidence of splenic injury. This was confirmed at operation in 1 patient and clinical follow-up in 26. There were one false negative and one false positive. In 5 patients (10%), CT demonstrated other clinically significant lesions, including hepatic or renal lacerations in 3 and large retroperitoneal hematomas in 2. In adolescents and adults, CT is an accurate, noninvasive method of rapidly diagnosing splenic trauma and associated injuries. Further experience is needed to assess its usefulness in evaluating splenic injuries in infants and small children

  11. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  12. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  13. Computed tomography in hepatic trauma

    International Nuclear Information System (INIS)

    Moon, K.L. Jr.; Federle, M.P.

    1983-01-01

    Twenty-five patients with hepatic injury from blunt upper abdominal trauma were examined by computed tomography (CT). The spectrum of CT findings was recorded, and the size of the hepatic laceration and the associated hemoperitoneum were correlated with the mode of therapy used in each case (operative vs nonoperative). While the need for surgery correlated roughly with the size of the hepatic laceration, the size of the associated hemoperitoneum was an important modifying factor. Fifteen patients with hepatic lacerations but little or no hemoperitoneum were managed nonoperatively. CT seems to have significant advantages over hepatic scintigraphy, angiography, and diagnostic peritoneal lavage. By combining inforamtion on the clinical state of the patient and CT findings, therapy of hepatic injury can be individualized and the incidence of nontherapeutic laparotomies decreased

  14. Breakeven analysis of computed tomography (Based on utilization of whole body C.T. scanner of SNU hospital)

    International Nuclear Information System (INIS)

    Cheung, Hwan; Choi, Myung Jun; Yoo, Chang Ho

    1986-01-01

    The C.T. scanner, an important tool for image-based diagnostics, is one of the costliest types of medical equipment. At present, there are in Korea a total of 66 units installed, and more units will be added in the future. For the fact the price of the C.T. scanner as well as scanning charge for using the equipment is very high as compared to those of the other kinds of medical equipment. The break-even analysis of computed tomography is considered fundamental as well as essential both to rational hospital management and keeping the charge for its use at an optimum level in consideration of the patient's medical expense burden. Even if pursuit of profits is not the role objective of a hospital, it cannot be denied that a break-even analysis provides an important factor for the decision making process in hospital management. The present study has the purpose of finding the ways and means to help rationalize hospital operation and improve its earning power through break-even analysis of C.T. scanner operation. For this purpose the total cost of the GE 8800 Whole Body C. T. Scanner installed at the Seoul National University Hospital was computed, and the records of its operation were analyzed. The expenses for its operation were divided into direct and indirect expenses depending on whether generation of the cost was recognized in the C. T. room or not, and the actual cost was computed for each of these accounting units

  15. Rapid data processing for ultrafast X-ray computed tomography using scalable and modular CUDA based pipelines

    Science.gov (United States)

    Frust, Tobias; Wagner, Michael; Stephan, Jan; Juckeland, Guido; Bieberle, André

    2017-10-01

    Ultrafast X-ray tomography is an advanced imaging technique for the study of dynamic processes basing on the principles of electron beam scanning. A typical application case for this technique is e.g. the study of multiphase flows, that is, flows of mixtures of substances such as gas-liquidflows in pipelines or chemical reactors. At Helmholtz-Zentrum Dresden-Rossendorf (HZDR) a number of such tomography scanners are operated. Currently, there are two main points limiting their application in some fields. First, after each CT scan sequence the data of the radiation detector must be downloaded from the scanner to a data processing machine. Second, the current data processing is comparably time-consuming compared to the CT scan sequence interval. To enable online observations or use this technique to control actuators in real-time, a modular and scalable data processing tool has been developed, consisting of user-definable stages working independently together in a so called data processing pipeline, that keeps up with the CT scanner's maximal frame rate of up to 8 kHz. The newly developed data processing stages are freely programmable and combinable. In order to achieve the highest processing performance all relevant data processing steps, which are required for a standard slice image reconstruction, were individually implemented in separate stages using Graphics Processing Units (GPUs) and NVIDIA's CUDA programming language. Data processing performance tests on different high-end GPUs (Tesla K20c, GeForce GTX 1080, Tesla P100) showed excellent performance. Program Files doi:http://dx.doi.org/10.17632/65sx747rvm.1 Licensing provisions: LGPLv3 Programming language: C++/CUDA Supplementary material: Test data set, used for the performance analysis. Nature of problem: Ultrafast computed tomography is performed with a scan rate of up to 8 kHz. To obtain cross-sectional images from projection data computer-based image reconstruction algorithms must be applied. The

  16. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  17. [Restoration filtering based on projection power spectrum for single-photon emission computed tomography].

    Science.gov (United States)

    Kubo, N

    1995-04-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical "least squares filter" theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the "Butterworth" filtering method (cut-off frequency of 0.15 cycles/pixel), and "Wiener" filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99mTc filled cylinder, were used. NMSE of the "Butterworth" filter, "Wiener" filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images.

  18. Restoration filtering based on projection power spectrum for single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kubo, Naoki

    1995-01-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical 'least squares filter' theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the 'Butterworth' filtering method (cut-off frequency of 0.15 cycles/pixel), and 'Wiener' filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99m Tc filled cylinder, were used. NMSE of the 'Butterworth' filter, 'Wiener' filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images. (author)

  19. Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee [Department of Radiological Sciences, University of California, Irvine, California 92697 (United States)

    2010-03-15

    Purpose: Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficult. Breast computed tomography using flat-panel detectors has been developed to address this limitation by producing three-dimensional data while at the same time providing more comfort to the patients by eliminating breast compression. Flat panels are charge integrating detectors and therefore lack energy resolution capability. Recent advances in solid state semiconductor x-ray detector materials and associated electronics allow the investigation of x-ray imaging systems that use a photon counting and energy discriminating detector, which is the subject of this article. Methods: A small field-of-view computed tomography (CT) system that uses CdZnTe (CZT) photon counting detector was compared to one that uses a flat-panel detector for different imaging tasks in breast imaging. The benefits afforded by the CZT detector in the energy weighting modes were investigated. Two types of energy weighting methods were studied: Projection based and image based. Simulation and phantom studies were performed with a 2.5 cm polymethyl methacrylate (PMMA) cylinder filled with iodine and calcium contrast objects. Simulation was also performed on a 10 cm breast specimen. Results: The contrast-to-noise ratio improvements as compared to flat-panel detectors were 1.30 and 1.28 (projection based) and 1.35 and 1.25 (image based) for iodine over PMMA and hydroxylapatite over PMMA, respectively. Corresponding simulation values were 1.81 and 1.48 (projection based) and 1.85 and 1.48 (image based). Dose reductions using the CZT detector were 52.05% and 49.45% for iodine and hydroxyapatite imaging, respectively. Image-based weighting was also found to have the least beam

  20. Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors

    International Nuclear Information System (INIS)

    Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee

    2010-01-01

    Purpose: Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficult. Breast computed tomography using flat-panel detectors has been developed to address this limitation by producing three-dimensional data while at the same time providing more comfort to the patients by eliminating breast compression. Flat panels are charge integrating detectors and therefore lack energy resolution capability. Recent advances in solid state semiconductor x-ray detector materials and associated electronics allow the investigation of x-ray imaging systems that use a photon counting and energy discriminating detector, which is the subject of this article. Methods: A small field-of-view computed tomography (CT) system that uses CdZnTe (CZT) photon counting detector was compared to one that uses a flat-panel detector for different imaging tasks in breast imaging. The benefits afforded by the CZT detector in the energy weighting modes were investigated. Two types of energy weighting methods were studied: Projection based and image based. Simulation and phantom studies were performed with a 2.5 cm polymethyl methacrylate (PMMA) cylinder filled with iodine and calcium contrast objects. Simulation was also performed on a 10 cm breast specimen. Results: The contrast-to-noise ratio improvements as compared to flat-panel detectors were 1.30 and 1.28 (projection based) and 1.35 and 1.25 (image based) for iodine over PMMA and hydroxylapatite over PMMA, respectively. Corresponding simulation values were 1.81 and 1.48 (projection based) and 1.85 and 1.48 (image based). Dose reductions using the CZT detector were 52.05% and 49.45% for iodine and hydroxyapatite imaging, respectively. Image-based weighting was also found to have the least beam

  1. A pseudo-discrete algebraic reconstruction technique (PDART) prior image-based suppression of high density artifacts in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Rizza; Park, Miran; Wi, Sunhee; Cho, Seungryong, E-mail: scho@kaist.ac.kr

    2016-12-21

    We propose a hybrid metal artifact reduction (MAR) approach for computed tomography (CT) that is computationally more efficient than a fully iterative reconstruction method, but at the same time achieves superior image quality to the interpolation-based in-painting techniques. Our proposed MAR method, an image-based artifact subtraction approach, utilizes an intermediate prior image reconstructed via PDART to recover the background information underlying the high density objects. For comparison, prior images generated by total-variation minimization (TVM) algorithm, as a realization of fully iterative approach, were also utilized as intermediate images. From the simulation and real experimental results, it has been shown that PDART drastically accelerates the reconstruction to an acceptable quality of prior images. Incorporating PDART-reconstructed prior images in the proposed MAR scheme achieved higher quality images than those by a conventional in-painting method. Furthermore, the results were comparable to the fully iterative MAR that uses high-quality TVM prior images. - Highlights: • An accelerated reconstruction method, PDART, is proposed for exterior problems. • With a few iterations, soft prior image was reconstructed from the exterior data. • PDART framework has enabled an efficient hybrid metal artifact reduction in CT.

  2. Comparison of Positron Emission Tomography Quantification Using Magnetic Resonance- and Computed Tomography-Based Attenuation Correction in Physiological Tissues and Lesions: A Whole-Body Positron Emission Tomography/Magnetic Resonance Study in 66 Patients.

    Science.gov (United States)

    Seith, Ferdinand; Gatidis, Sergios; Schmidt, Holger; Bezrukov, Ilja; la Fougère, Christian; Nikolaou, Konstantin; Pfannenberg, Christina; Schwenzer, Nina

    2016-01-01

    Attenuation correction (AC) in fully integrated positron emission tomography (PET)/magnetic resonance (MR) systems plays a key role for the quantification of tracer uptake. The aim of this prospective study was to assess the accuracy of standardized uptake value (SUV) quantification using MR-based AC in direct comparison with computed tomography (CT)-based AC of the same PET data set on a large patient population. Sixty-six patients (22 female; mean [SD], 61 [11] years) were examined by means of combined PET/CT and PET/MR (11C-choline, 18F-FDG, or 68Ga-DOTATATE) subsequently. Positron emission tomography images from PET/MR examinations were corrected with MR-derived AC based on tissue segmentation (PET(MR)). The same PET data were corrected using CT-based attenuation maps (μ-maps) derived from PET/CT after nonrigid registration of the CT to the MR-based μ-map (PET(MRCT)). Positron emission tomography SUVs were quantified placing regions of interest or volumes of interest in 6 different body regions as well as PET-avid lesions, respectively. The relative differences of quantitative PET values when using MR-based AC versus CT-based AC were varying depending on the organs and body regions assessed. In detail, the mean (SD) relative differences of PET SUVs were as follows: -7.8% (11.5%), blood pool; -3.6% (5.8%), spleen; -4.4% (5.6%)/-4.1% (6.2%), liver; -0.6% (5.0%), muscle; -1.3% (6.3%), fat; -40.0% (18.7%), bone; 1.6% (4.4%), liver lesions; -6.2% (6.8%), bone lesions; and -1.9% (6.2%), soft tissue lesions. In 10 liver lesions, distinct overestimations greater than 5% were found (up to 10%). In addition, overestimations were found in 2 bone lesions and 1 soft tissue lesion adjacent to the lung (up to 28.0%). Results obtained using different PET tracers show that MR-based AC is accurate in most tissue types, with SUV deviations generally of less than 10%. In bone, however, underestimations can be pronounced, potentially leading to inaccurate SUV quantifications. In

  3. Radiological protection in computed tomography and cone beam computed tomography.

    Science.gov (United States)

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    Science.gov (United States)

    Wagner, Maximilian E H; Gellrich, Nils-Claudius; Friese, Karl-Ingo; Becker, Matthias; Wolter, Franz-Erich; Lichtenstein, Juergen T; Stoetzer, Marcus; Rana, Majeed; Essig, Harald

    2016-01-01

    Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior tissue representation, although CBCT has the benefit of greater availability and lower patient radiation exposure. Therefore, a model-based segmentation technique is presented as a new method for measuring orbital volume and compared to alternative techniques. Both eyes from thirty subjects with no known orbital pathology who had undergone CBCT as a part of routine care were evaluated (n = 60 eyes). Orbital volume was measured with manual, atlas-based, and model-based segmentation methods. Volume measurements, volume determination time, and usability were compared between the three methods. Differences in means were tested for statistical significance using two-tailed Student's t tests. Neither atlas-based (26.63 ± 3.15 mm(3)) nor model-based (26.87 ± 2.99 mm(3)) measurements were significantly different from manual volume measurements (26.65 ± 4.0 mm(3)). However, the time required to determine orbital volume was significantly longer for manual measurements (10.24 ± 1.21 min) than for atlas-based (6.96 ± 2.62 min, p < 0.001) or model-based (5.73 ± 1.12 min, p < 0.001) measurements. All three orbital volume measurement methods examined can accurately measure orbital volume, although atlas-based and model-based methods seem to be more user-friendly and less time-consuming. The new model-based technique achieves fully automated segmentation results, whereas all atlas-based segmentations at least required manipulations to the anterior closing. Additionally, model-based segmentation can provide reliable orbital volume measurements when CT image quality is poor.

  5. Computed Tomography Image Origin Identification Based on Original Sensor Pattern Noise and 3-D Image Reconstruction Algorithm Footprints.

    Science.gov (United States)

    Duan, Yuping; Bouslimi, Dalel; Yang, Guanyu; Shu, Huazhong; Coatrieux, Gouenou

    2017-07-01

    In this paper, we focus on the "blind" identification of the computed tomography (CT) scanner that has produced a CT image. To do so, we propose a set of noise features derived from the image chain acquisition and which can be used as CT-scanner footprint. Basically, we propose two approaches. The first one aims at identifying a CT scanner based on an original sensor pattern noise (OSPN) that is intrinsic to the X-ray detectors. The second one identifies an acquisition system based on the way this noise is modified by its three-dimensional (3-D) image reconstruction algorithm. As these reconstruction algorithms are manufacturer dependent and kept secret, our features are used as input to train a support vector machine (SVM) based classifier to discriminate acquisition systems. Experiments conducted on images issued from 15 different CT-scanner models of 4 distinct manufacturers demonstrate that our system identifies the origin of one CT image with a detection rate of at least 94% and that it achieves better performance than sensor pattern noise (SPN) based strategy proposed for general public camera devices.

  6. Quantification of root water uptake in soil using X-ray computed tomography and image-based modelling.

    Science.gov (United States)

    Daly, Keith R; Tracy, Saoirse R; Crout, Neil M J; Mairhofer, Stefan; Pridmore, Tony P; Mooney, Sacha J; Roose, Tiina

    2018-01-01

    Spatially averaged models of root-soil interactions are often used to calculate plant water uptake. Using a combination of X-ray computed tomography (CT) and image-based modelling, we tested the accuracy of this spatial averaging by directly calculating plant water uptake for young wheat plants in two soil types. The root system was imaged using X-ray CT at 2, 4, 6, 8 and 12 d after transplanting. The roots were segmented using semi-automated root tracking for speed and reproducibility. The segmented geometries were converted to a mesh suitable for the numerical solution of Richards' equation. Richards' equation was parameterized using existing pore scale studies of soil hydraulic properties in the rhizosphere of wheat plants. Image-based modelling allows the spatial distribution of water around the root to be visualized and the fluxes into the root to be calculated. By comparing the results obtained through image-based modelling to spatially averaged models, the impact of root architecture and geometry in water uptake was quantified. We observed that the spatially averaged models performed well in comparison to the image-based models with <2% difference in uptake. However, the spatial averaging loses important information regarding the spatial distribution of water near the root system. © 2017 John Wiley & Sons Ltd.

  7. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  8. Ex-situ X-ray computed tomography data for a non-crimp fabric based glass fibre composite under fatigue loading

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2017-01-01

    The data published with this article are high resolution X-ray computed tomography (CT) data obtained during an ex-situ fatigue test of a coupon test specimen made from a non-crimp fabric based glass fibre composite similar to those used for wind turbine blades. The fatigue test was interrupted...

  9. Cat Swarm Optimization Based Functional Link Artificial Neural Network Filter for Gaussian Noise Removal from Computed Tomography Images

    Directory of Open Access Journals (Sweden)

    M. Kumar

    2016-01-01

    Full Text Available Gaussian noise is one of the dominant noises, which degrades the quality of acquired Computed Tomography (CT image data. It creates difficulties in pathological identification or diagnosis of any disease. Gaussian noise elimination is desirable to improve the clarity of a CT image for clinical, diagnostic, and postprocessing applications. This paper proposes an evolutionary nonlinear adaptive filter approach, using Cat Swarm Functional Link Artificial Neural Network (CS-FLANN to remove the unwanted noise. The structure of the proposed filter is based on the Functional Link Artificial Neural Network (FLANN and the Cat Swarm Optimization (CSO is utilized for the selection of optimum weight of the neural network filter. The applied filter has been compared with the existing linear filters, like the mean filter and the adaptive Wiener filter. The performance indices, such as peak signal to noise ratio (PSNR, have been computed for the quantitative analysis of the proposed filter. The experimental evaluation established the superiority of the proposed filtering technique over existing methods.

  10. Software-based risk stratification of pulmonary adenocarcinomas manifesting as pure ground glass nodules on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Ursula [Vienna General Hospital, Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Heidinger, Benedikt H.; Bankier, Alexander A. [Harvard Medical School, Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Anderson, Kevin R.; VanderLaan, Paul A. [Harvard Medical School, Pathology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Westmore, Michael S. [Imbio, Delafield, WI (United States)

    2018-01-15

    To assess the performance of the ''Computer-Aided Nodule Assessment and Risk Yield'' (CANARY) software in the differentiation and risk assessment of histological subtypes of lung adenocarcinomas manifesting as pure ground glass nodules on computed tomography (CT). 64 surgically resected and histologically proven adenocarcinomas manifesting as pure ground-glass nodules on CT were assessed using CANARY software, which classifies voxel-densities into three risk components (low, intermediate, and high risk). Differences in risk components between histological adenocarcinoma subtypes were analysed. To determine the optimal threshold reflecting the presence of an invasive focus, sensitivity, specificity, negative predictive value, and positive predictive value were calculated. 28/64 (44%) were adenocarcinomas in situ (AIS); 26/64 (41%) were minimally invasive adenocarcinomas (MIA); and 10/64 (16%) were invasive ACs (IAC). The software showed significant differences in risk components between histological subtypes (P<0.001-0.003). A relative volume of 45% or less of low-risk components was associated with histological invasiveness (specificity 100%, positive predictive value 100%). CANARY-based risk assessment of ACs manifesting as pure ground glass nodules on CT allows the differentiation of their histological subtypes. A threshold of 45% of low-risk components reflects invasiveness in these groups. (orig.)

  11. Software-based risk stratification of pulmonary adenocarcinomas manifesting as pure ground glass nodules on computed tomography

    International Nuclear Information System (INIS)

    Nemec, Ursula; Heidinger, Benedikt H.; Bankier, Alexander A.; Anderson, Kevin R.; VanderLaan, Paul A.; Westmore, Michael S.

    2018-01-01

    To assess the performance of the ''Computer-Aided Nodule Assessment and Risk Yield'' (CANARY) software in the differentiation and risk assessment of histological subtypes of lung adenocarcinomas manifesting as pure ground glass nodules on computed tomography (CT). 64 surgically resected and histologically proven adenocarcinomas manifesting as pure ground-glass nodules on CT were assessed using CANARY software, which classifies voxel-densities into three risk components (low, intermediate, and high risk). Differences in risk components between histological adenocarcinoma subtypes were analysed. To determine the optimal threshold reflecting the presence of an invasive focus, sensitivity, specificity, negative predictive value, and positive predictive value were calculated. 28/64 (44%) were adenocarcinomas in situ (AIS); 26/64 (41%) were minimally invasive adenocarcinomas (MIA); and 10/64 (16%) were invasive ACs (IAC). The software showed significant differences in risk components between histological subtypes (P<0.001-0.003). A relative volume of 45% or less of low-risk components was associated with histological invasiveness (specificity 100%, positive predictive value 100%). CANARY-based risk assessment of ACs manifesting as pure ground glass nodules on CT allows the differentiation of their histological subtypes. A threshold of 45% of low-risk components reflects invasiveness in these groups. (orig.)

  12. The construction and evaluation of a prototype system for an image intensifier-based volume computed tomography imager

    International Nuclear Information System (INIS)

    Ning, R.

    1989-01-01

    A volumetric reconstruction of a three-dimensional (3-D) object has been at the forefront of exploration in medical applications for a long time. To achieve this goal, a prototype system for an image intensifier(II)-based volume computed tomography (CT) imager has been constructed. This research has been concerned with constructing and evaluating such a prototype system by phantom studies. The prototype system consists of a fixed x-ray tube, a specially designed aluminum filter that will reduce the dynamic range of projection data, an antiscatter grid, a conventional image intensifier optically coupled to a charge-coupled device (CCC) camera, a computer controlled turntable on which phantoms are placed, a digital computer including an A/D converter and a graphic station that displays the reconstructed images. In this study, three different phantoms were used: a vascular phantom, a resolution phantom and a Humanoid reg-sign chest phantom. The direct 3-D reconstruction from the projections was performed using a cone beam algorithm and vascular reconstruction algorithms. The image performance of the system for the direct 3-D reconstruction was evaluated. The spatial resolution limits of the system were estimated through observing the reconstructed images of the resolution phantom. By observing the images reconstructed from the projections, it can be determined that the image performance of the prototype system for a direct 3-D reconstruction is reasonably good and that the vascular reconstruction algorithms work very well. The results also indicate that the 3-D reconstructions obtained with the 11-based volume CT imager have nearly equally good resolution in x, y and z directions and are superior to a conventional CT in the resolution of the z direction

  13. Statistical-techniques-based computer-aided diagnosis (CAD) using texture feature analysis: application in computed tomography (CT) imaging to fatty liver disease

    Science.gov (United States)

    Chung, Woon-Kwan; Park, Hyong-Hu; Im, In-Chul; Lee, Jae-Seung; Goo, Eun-Hoe; Dong, Kyung-Rae

    2012-09-01

    This paper proposes a computer-aided diagnosis (CAD) system based on texture feature analysis and statistical wavelet transformation technology to diagnose fatty liver disease with computed tomography (CT) imaging. In the target image, a wavelet transformation was performed for each lesion area to set the region of analysis (ROA, window size: 50 × 50 pixels) and define the texture feature of a pixel. Based on the extracted texture feature values, six parameters (average gray level, average contrast, relative smoothness, skewness, uniformity, and entropy) were determined to calculate the recognition rate for a fatty liver. In addition, a multivariate analysis of the variance (MANOVA) method was used to perform a discriminant analysis to verify the significance of the extracted texture feature values and the recognition rate for a fatty liver. According to the results, each texture feature value was significant for a comparison of the recognition rate for a fatty liver ( p fatty liver had the same scale as that for the F-value, showing 100% (average gray level) at the maximum and 80% (average contrast) at the minimum. Therefore, the recognition rate is believed to be a useful clinical value for the automatic detection and computer-aided diagnosis (CAD) using the texture feature value. Nevertheless, further study on various diseases and singular diseases will be needed in the future.

  14. Implementation of a web-based, interactive polytrauma tutorial in computed tomography for radiology residents: How we do it

    International Nuclear Information System (INIS)

    Schlorhaufer, C.; Behrends, M.; Diekhaus, G.; Keberle, M.; Weidemann, J.

    2012-01-01

    Purpose: Due to the time factor in polytraumatized patients all relevant pathologies in a polytrauma computed tomography (CT) scan have to be read and communicated very quickly. During radiology residency acquisition of effective reading schemes based on typical polytrauma pathologies is very important. Thus, an online tutorial for the structured diagnosis of polytrauma CT was developed. Materials and methods: Based on current multimedia theories like the cognitive load theory a didactic concept was developed. As a web-environment the learning management system ILIAS was chosen. CT data sets were converted into online scrollable QuickTime movies. Audiovisual tutorial movies with guided image analyses by a consultant radiologist were recorded. Results: The polytrauma tutorial consists of chapterized text content and embedded interactive scrollable CT data sets. Selected trauma pathologies are demonstrated to the user by guiding tutor movies. Basic reading schemes are communicated with the help of detailed commented movies of normal data sets. Common and important pathologies could be explored in a self-directed manner. Conclusions: Ambitious didactic concepts can be supported by a web based application on the basis of cognitive load theory and currently available software tools.

  15. Comparison of analyzer-based imaging computed tomography extraction algorithms and application to bone-cartilage imaging

    International Nuclear Information System (INIS)

    Diemoz, Paul C; Bravin, Alberto; Coan, Paola; Glaser, Christian

    2010-01-01

    In x-ray phase-contrast analyzer-based imaging, the contrast is provided by a combination of absorption, refraction and scattering effects. Several extraction algorithms, which attempt to separate and quantify these different physical contributions, have been proposed and applied. In a previous work, we presented a quantitative comparison of five among the most well-known extraction algorithms based on the geometrical optics approximation applied to planar images: diffraction-enhanced imaging (DEI), extended diffraction-enhanced imaging (E-DEI), generalized diffraction-enhanced imaging (G-DEI), multiple-image radiography (MIR) and Gaussian curve fitting (GCF). In this paper, we compare these algorithms in the case of the computed tomography (CT) modality. The extraction algorithms are applied to analyzer-based CT images of both plastic phantoms and biological samples (cartilage-on-bone cylinders). Absorption, refraction and scattering signals are derived. Results obtained with the different algorithms may vary greatly, especially in the case of large refraction angles. We show that ABI-CT extraction algorithms can provide an excellent tool to enhance the visualization of cartilage internal structures, which may find applications in a clinical context. Besides, by using the refraction images, the refractive index decrements for both the cartilage matrix and the cartilage cells have been estimated.

  16. Parotid gland sparing effect by computed tomography-based modified lower field margin in whole brain radiotherapy

    International Nuclear Information System (INIS)

    Cho, Oyeon; Chun, Mi Son; Oh, Young Taek; Kim, Mi Hwa; Park, Hae Jin; Nam, Sang Soo; Heo, Jae Sung; Noh, O Kyu; Park, Sung Ho

    2013-01-01

    Parotid gland can be considered as a risk organ in whole brain radiotherapy (WBRT). The purpose of this study is to evaluate the parotid gland sparing effect of computed tomography (CT)-based WBRT compared to 2-dimensional plan with conventional field margin. From January 2008 to April 2011, 53 patients underwent WBRT using CT-based simulation. Bilateral two-field arrangement was used and the prescribed dose was 30 Gy in 10 fractions. We compared the parotid dose between 2 radiotherapy plans using different lower field margins: conventional field to the lower level of the atlas (CF) and modified field fitted to the brain tissue (MF). Averages of mean parotid dose of the 2 protocols with CF and MF were 17.4 Gy and 8.7 Gy, respectively (p 98% of prescribed dose were 99.7% for CF and 99.5% for MF. Compared to WBRT with CF, CT-based lower field margin modification is a simple and effective technique for sparing the parotid gland, while providing similar dose coverage of the whole brain.

  17. Implementation of a web-based, interactive polytrauma tutorial in computed tomography for radiology residents: How we do it

    Energy Technology Data Exchange (ETDEWEB)

    Schlorhaufer, C., E-mail: Schlorhaufer.Celia@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Behrends, M., E-mail: behrends.marianne@mh-hannover.de [Peter L. Reichertz Department of Medical Informatics, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Diekhaus, G., E-mail: Diekhaus.Gesche@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Keberle, M., E-mail: m.keberle@bk-paderborn.de [Department of Diagnostic and Interventional Radiology, Brüderkrankenhaus St. Josef Paderborn, Husener Str. 46, 33098 Paderborn (Germany); Weidemann, J., E-mail: Weidemann.Juergen@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2012-12-15

    Purpose: Due to the time factor in polytraumatized patients all relevant pathologies in a polytrauma computed tomography (CT) scan have to be read and communicated very quickly. During radiology residency acquisition of effective reading schemes based on typical polytrauma pathologies is very important. Thus, an online tutorial for the structured diagnosis of polytrauma CT was developed. Materials and methods: Based on current multimedia theories like the cognitive load theory a didactic concept was developed. As a web-environment the learning management system ILIAS was chosen. CT data sets were converted into online scrollable QuickTime movies. Audiovisual tutorial movies with guided image analyses by a consultant radiologist were recorded. Results: The polytrauma tutorial consists of chapterized text content and embedded interactive scrollable CT data sets. Selected trauma pathologies are demonstrated to the user by guiding tutor movies. Basic reading schemes are communicated with the help of detailed commented movies of normal data sets. Common and important pathologies could be explored in a self-directed manner. Conclusions: Ambitious didactic concepts can be supported by a web based application on the basis of cognitive load theory and currently available software tools.

  18. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  19. Computed tomography of obstructive jaundice

    International Nuclear Information System (INIS)

    Suh, Jung Hek; Lee, Joong Suk; Chun, Beung He; Suh, Soo Jhi

    1982-01-01

    It is well known that the computed tomography (CT) is very useful in the evaluation of obstructive jaundice. We have studied 55 cases of obstructive jaundice with whole body scanner from Jun.1980 to Jun. 1981. The results were as follows: 1. The sex distribution was 36 males and 19 females, and 40 cases of obstructive jaundice were seen in fifth, sixth, and seventh decades. 2. Causes of obstructive jaundice were 25 cases of pancreas cancer, 8 cases of common duct cancer, 4 cases of gallbladder cancer, 4 cases of ampulla vater cancer, 12 cases of common duct stone, and 2 cases of common duct stricture. 3. Levels of obstruction were 8 cases of hepatic portion, 15 cases of suprapancreatic portion, 28 cases of pancreatic portion, and 4 cases of ampullary portion. 4. In tumorous condition, CT demonstrated metastasis of other organs, 9 cases of the liver, 1 case of the lung, 3 cases of the pancreas, 3 cases of the common bile duct, 1 case of the stomach, and 12 cases of adjacent lymph nodes. 5. Associated diseases were 12 cases of intrahepatic stone, 4 cases of clonorchiasis, 2 cases of pancreas pseudocyst, 1 cases of hydronephrosis, and 1 case of renal cyst

  20. Errors in abdominal computed tomography

    International Nuclear Information System (INIS)

    Stephens, S.; Marting, I.; Dixon, A.K.

    1989-01-01

    Sixty-nine patients are presented in whom a substantial error was made on the initial abdominal computed tomography report. Certain features of these errors have been analysed. In 30 (43.5%) a lesion was simply not recognised (error of observation); in 39 (56.5%) the wrong conclusions were drawn about the nature of normal or abnormal structures (error of interpretation). The 39 errors of interpretation were more complex; in 7 patients an abnormal structure was noted but interpreted as normal, whereas in four a normal structure was thought to represent a lesion. Other interpretive errors included those where the wrong cause for a lesion had been ascribed (24 patients), and those where the abnormality was substantially under-reported (4 patients). Various features of these errors are presented and discussed. Errors were made just as often in relation to small and large lesions. Consultants made as many errors as senior registrar radiologists. It is like that dual reporting is the best method of avoiding such errors and, indeed, this is widely practised in our unit. (Author). 9 refs.; 5 figs.; 1 tab

  1. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  2. X-ray computed tomography

    International Nuclear Information System (INIS)

    Kalender, Willi A

    2006-01-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  3. Computed tomography of epileptic children

    International Nuclear Information System (INIS)

    Kurihara, Mana; Yamashita, Sumimasa; Miyake, Shota; Yamada, Michiko; Iwamoto, Hiroko

    1986-01-01

    The aim of this study was to analyze the changes seen on cranial computed tomography (CT) of epileptic children, especially in the area of the temporal horn. The subjects were 242 epileptic children excluding those with encephalitis, brain tumor, neurocutaneous syndromes, degenerative disease, hydrocephalus etc. The control subjects were 195 children without any neurological disease and symptoms. CT scan were taken with a TCT-60A whole body scanner, and 14 check points were evaluated excluding the temporal horn. 195 epileptic children (N-group) and all control children were normal at 14 check points. Next, the areas of the temporal horns and adjoining hemispheres of the epileptic children (N-group) and control children were examined with Muto-Tablet-Desitizer. The temporal horn ratio ((area of temporal horn/area of ipsilateral hemisphere) x 100) was greater in younger children of the control group, and it was higher in epileptic than in control children. Enlargement of the temporal horn was seen in 1 % of the controls and in 35 % of the 125 epileptic children with normal measurements at 14 points on CT scans (p < 0.01). The frequency of enlargement of temporal horns was not variable among different epileptic types. In the epileptic children with normal CT scans except for enlargement of temporal horns behavioral disturbances were 6 boys and 5 had enlarged temporal horns (bilateral 1 case, left side 1 case, right side 3 cases). (author)

  4. Computed Tomography of Interacerebral Hemorrhage

    International Nuclear Information System (INIS)

    Kim, Seung Hyeon; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Park, Soo Soung

    1983-01-01

    Computed tomography (CT) is the most accurate and reliable method for the diagnosis of intracerebral and intraventricular hemorrhage. The precise anatomic extent of the nematoma, associated cerebral edema, ventricular deformity and displacement, and hydrocephalus are all readily assessed. Aside from head trauma, the principal cause of intracerebral hematoma is hypertensive vascular disease. Although hematomas from various causes may present similar CT appearances frequently the correct etiology may be suggested by consideration of patient's age, clinical history, and the location of the hematoma. The analytical study was performed in 180 cases of intracerebral hemorrhages by CT from October 1981 to January 1983. The results were as follows; 1. The most prevalent age group was 6th decade (37.2%). Male was prevalent to female at the ration of 1.6 to 1. 2. The most common symptom and sign was mental disturbance (48.7%), motor weakness (23%), headache (10.6%), nausea and vomiting (9.8%). 3. The causes of hemorrhage were hypertension (53.9%), head trauma (30.6%), aneurysm (6.1%) and A-V malformation (7.2%). 4. The frequent locations of hemorrhage were basal ganglia and thalamus (40.4%), lobes (35%), ventricles (21.8%). 5. The distribution of hemorrhage was intracerebral hemorrhage (65.6%), intracerebral and intraventricular hemorrhage (30.3%), intraventricular hemorrhage (4.4%).

  5. Use of 4-Dimensional Computed Tomography-Based Ventilation Imaging to Correlate Lung Dose and Function With Clinical Outcomes

    International Nuclear Information System (INIS)

    Vinogradskiy, Yevgeniy; Castillo, Richard; Castillo, Edward; Tucker, Susan L.; Liao, Zhongxing; Guerrero, Thomas; Martel, Mary K.

    2013-01-01

    Purpose: Four-dimensional computed tomography (4DCT)-based ventilation is an emerging imaging modality that can be used in the thoracic treatment planning process. The clinical benefit of using ventilation images in radiation treatment plans remains to be tested. The purpose of the current work was to test the potential benefit of using ventilation in treatment planning by evaluating whether dose to highly ventilated regions of the lung resulted in increased incidence of clinical toxicity. Methods and Materials: Pretreatment 4DCT data were used to compute pretreatment ventilation images for 96 lung cancer patients. Ventilation images were calculated using 4DCT data, deformable image registration, and a density-change based algorithm. Dose–volume and ventilation-based dose function metrics were computed for each patient. The ability of the dose–volume and ventilation-based dose–function metrics to predict for severe (grade 3+) radiation pneumonitis was assessed using logistic regression analysis, area under the curve (AUC) metrics, and bootstrap methods. Results: A specific patient example is presented that demonstrates how incorporating ventilation-based functional information can help separate patients with and without toxicity. The logistic regression significance values were all lower for the dose–function metrics (range P=.093-.250) than for their dose–volume equivalents (range, P=.331-.580). The AUC values were all greater for the dose–function metrics (range, 0.569-0.620) than for their dose–volume equivalents (range, 0.500-0.544). Bootstrap results revealed an improvement in model fit using dose–function metrics compared to dose–volume metrics that approached significance (range, P=.118-.155). Conclusions: To our knowledge, this is the first study that attempts to correlate lung dose and 4DCT ventilation-based function to thoracic toxicity after radiation therapy. Although the results were not significant at the .05 level, our data suggests

  6. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  7. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  8. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  9. The dental cavities of equine cheek teeth: three-dimensional reconstructions based on high resolution micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Kopke Susan

    2012-09-01

    Full Text Available Abstract Background Recent studies reported on the very complex morphology of the pulp system in equine cheek teeth. The continuous production of secondary dentine leads to distinct age-related changes of the endodontic cavity. Detailed anatomical knowledge of the dental cavities in all ages is required to explain the aetiopathology of typical equine endodontic diseases. Furthermore, data on mandibular and maxillary pulp systems is in high demand to provide a basis for the development of endodontic therapies. However, until now examination of the pulp cavity has been based on either sectioned teeth or clinical computed tomography. More precise results were expected by using micro-computed tomography with a resolution of about 0.1 mm and three-dimensional reconstructions based on previous greyscale analyses and histological verification. The aim of the present study was to describe the physiological configurations of the pulp system within a wide spectrum of tooth ages. Results Maxillary teeth: All morphological constituents of the endodontic cavity were present in teeth between 4 and 16 years: Triadan 06s displayed six pulp horns and five root canals, Triadan 07-10s five pulp horns and four root canals and Triadan 11s seven pulp horns and four to six root canals. A common pulp chamber was most frequent in teeth ≤5 years, but was found even in a tooth of 9 years. A large variety of pulp configurations was observed within 2.5 and 16 years post eruption, but most commonly a separation into mesial and distal pulp compartments was seen. Maxillary cheek teeth showed up to four separate pulp compartments but the frequency of two, three and four pulp compartments was not related to tooth age (P > 0.05. In Triadan 06s, pulp horn 6 was always connected to pulp horns 1 and 3 and root canal I. In Triadan 11s, pulp horns 7 and 8 were present in variable constitutions. Mandibular teeth: A common pulp chamber was present in teeth up to 15 years, but most

  10. Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure

    Energy Technology Data Exchange (ETDEWEB)

    Wick, Carson A.; McClellan, James H. [School of Electrical and Computer Engineering, Georgia Institute of Technology, 777 Atlantic Drive Northwest, Atlanta, Georgia 30332 (United States); Arepalli, Chesnal D. [Department of Radiology, University of British Columbia, 3350-950 West 10th Avenue, Vancouver, British Columbia V5Z 4E3 (Canada); Auffermann, William F.; Henry, Travis S. [Department of Radiology and Imaging Sciences, Emory University, Division of Cardiothoracic Imaging, 1364 Clifton Road Northeast, Suite 309, Atlanta, Georgia 30322 (United States); Khosa, Faisal [Department of Radiology and Imaging Sciences, Emory University, Division of Emergency Radiology, 550 Peachtree Street Northeast, Atlanta, Georgia 30308 (United States); Coy, Adam M. [School of Medicine, Emory University, 100 Woodruff Circle, Atlanta, Georgia 30322 (United States); Tridandapani, Srini, E-mail: stridan@emory.edu [Department of Radiology and Imaging Sciences, Emory University, Winship Cancer Institute, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 and School of Electrical and Computer Engineering, Georgia Institute of Technology, 777 Atlantic Drive Northwest, Atlanta, Georgia 30332 (United States)

    2015-02-15

    Purpose: Accurate knowledge of cardiac quiescence is crucial to the performance of many cardiac imaging modalities, including computed tomography coronary angiography (CTCA). To accurately quantify quiescence, a method for detecting the quiescent periods of the heart from retrospective cardiac computed tomography (CT) using a correlation-based, phase-to-phase deviation measure was developed. Methods: Retrospective cardiac CT data were obtained from 20 patients (11 male, 9 female, 33–74 yr) and the left main, left anterior descending, left circumflex, right coronary artery (RCA), and interventricular septum (IVS) were segmented for each phase using a semiautomated technique. Cardiac motion of individual coronary vessels as well as the IVS was calculated using phase-to-phase deviation. As an easily identifiable feature, the IVS was analyzed to assess how well it predicts vessel quiescence. Finally, the diagnostic quality of the reconstructed volumes from the quiescent phases determined using the deviation measure from the vessels in aggregate and the IVS was compared to that from quiescent phases calculated by the CT scanner. Three board-certified radiologists, fellowship-trained in cardiothoracic imaging, graded the diagnostic quality of the reconstructions using a Likert response format: 1 = excellent, 2 = good, 3 = adequate, 4 = nondiagnostic. Results: Systolic and diastolic quiescent periods were identified for each subject from the vessel motion calculated using the phase-to-phase deviation measure. The motion of the IVS was found to be similar to the aggregate vessel (AGG) motion. The diagnostic quality of the coronary vessels for the quiescent phases calculated from the aggregate vessel (P{sub AGG}) and IVS (P{sub IV} {sub S}) deviation signal using the proposed methods was comparable to the quiescent phases calculated by the CT scanner (P{sub CT}). The one exception was the RCA, which improved for P{sub AGG} for 18 of the 20 subjects when compared to P

  11. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  12. Noncontrast cardiac computed tomography image-based vertebral bone mineral density: the Multi-Ethnic Study of Atherosclerosis (MESA).

    Science.gov (United States)

    Li, Dong; Mao, Song Shou; Khazai, Bahram; Hyder, Joseph A; Allison, Matthew; McClelland, Robyn; de Boer, Ian; Carr, J Jeffrey; Criqui, Michael H; Gao, Yanlin; Budoff, Matthew J

    2013-05-01

    Cardiac computer tomography (CT) image-based vertebral bone mineral density (BMD) assessment and the influence of cardiovascular disease risk factors on BMD have not been systematically evaluated, especially in a community-based, multiethnic population. A cross-sectional study design is used to determine if cardiac CT image is a reliable source to assess vertebral BMD, and a total of 2028 CT images were obtained from the Multi-Ethnic Study of Atherosclerosis, a large, diverse US cohort of adults 45 to 84 years of age. Cardiac CT image allows the rapid assessment of vertebral BMD and related fractures. The mean BMD was significantly higher in men compared with women for thoracic vertebrae (143.2 ± 41.2 vs 138.7 ± 42.7 mg/cm³, respectively, P = .014), as well as for lumbar vertebrae (125.0 ± 37.9 vs 117.2 ± 39.4 mg/cm³, respectively, P images to garner and assess vertebral BMD is a feasible and reliable method. Cardiac CT has the additional advantages of evaluate vertebral bone health while assessing cardiovascular disease risk with no extra cost or radiation exposure. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  13. Automated Extraction of Cranial Landmarks from Computed Tomography Data using a Combined Method of Knowledge and Pattern Based Approaches

    Directory of Open Access Journals (Sweden)

    Roshan N. RAJAPAKSE

    2016-03-01

    Full Text Available Accurate identification of anatomical structures from medical imaging data is a significant and critical function in the medical domain. Past studies in this context have mainly utilized two main approaches, the knowledge and learning methodologies based methods. Further, most of previous reported studies have focused on identification of landmarks from lateral X-ray Computed Tomography (CT data, particularly in the field of orthodontics. However, this study focused on extracting cranial landmarks from large sets of cross sectional CT slices using a combined method of the two aforementioned approaches. The proposed method of this study is centered mainly on template data sets, which were created using the actual contour patterns extracted from CT cases for each of the landmarks in consideration. Firstly, these templates were used to devise rules which are a characteristic of the knowledge based method. Secondly, the same template sets were employed to perform template matching related to the learning methodologies approach. The proposed method was tested on two landmarks, the Dorsum sellae and the Pterygoid plate, using CT cases of 5 subjects. The results indicate that, out of the 10 tests, the output images were within the expected range (desired accuracy in 7 instances and acceptable range (near accuracy for 2 instances, thus verifying the effectiveness of the combined template sets centric approach proposed in this study.

  14. Proposal for a structured computed tomography report in the evaluation of pancreatic neoplasms based on expert opinions

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Paulo Gustavo Maciel; Matsumoto, Carlos Alberto; Lobo, Edson José; D' Ippolito, Giuseppe, E-mail: pgmlopes87@gmail.com [Universidade Federal de São Paulo (EPM/UNIFESP), SP (Brazil). Escola de Medicina

    2018-03-15

    Objective: To create a structured computed tomography (CT) report for the systematic evaluation of pancreatic ductal adenocarcinoma (PDAC), based on the opinions of clinicians and surgeons. Materials And Methods: This was a prospective study in which we applied a 21-item questionnaire to experts in pancreatic diseases in order to create a model of a structured abdominal CT report. The questionnaire addressed the location and size of PDACs, as well as their effects on adjacent structures and on the vasculature, together with metastases. We used a Likert scale to determine which of those parameters should be included in the model. Results: A total of 18 experts (12 surgeons and 6 clinicians) from 9 institutions completed the questionnaire. All of the experts agreed that the following (if present) should be described in the CT report on a PDAC: the degree of enhancement; the diameter and location of the lesion; pancreatic duct obstruction; biliary dilatation; pancreatic atrophy; liver metastases; peritoneal nodules; ascites; lymph node enlargement; and invasion of adjacent structures. More than 80% of the experts agreed that the report should also describe the relationship between the PDAC and the surrounding vasculature. Conclusion: We have developed a template for a CT report on patients with PDAC, based on the opinions of experts involved in the treatment of such patients. (author)

  15. Favorable noise uniformity properties of Fourier-based interpolation and reconstruction approaches in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    Volumes reconstructed by standard methods from single-slice helical computed tomography (CT) data have been shown to have noise levels that are highly nonuniform relative to those in conventional CT. These noise nonuniformities can affect low-contrast object detectability and have also been identified as the cause of the zebra artifacts that plague maximum intensity projection (MIP) images of such volumes. While these spatially variant noise levels have their root in the peculiarities of the helical scan geometry, there is also a strong dependence on the interpolation and reconstruction algorithms employed. In this paper, we seek to develop image reconstruction strategies that eliminate or reduce, at its source, the nonuniformity of noise levels in helical CT relative to that in conventional CT. We pursue two approaches, independently and in concert. We argue, and verify, that Fourier-based longitudinal interpolation approaches lead to more uniform noise ratios than do the standard 360LI and 180LI approaches. We also demonstrate that a Fourier-based fan-to-parallel rebinning algorithm, used as an alternative to fanbeam filtered backprojection for slice reconstruction, also leads to more uniform noise ratios, even when making use of the 180LI and 360LI interpolation approaches

  16. NCT-ART - a neutron computer tomography code based on the algebraic reconstruction technique

    International Nuclear Information System (INIS)

    Krueger, A.

    1988-01-01

    A computer code is presented, which calculates two-dimensional cuts of material assemblies from a number of neutron radiographic projections. Mathematically, the reconstruction is performed by an iterative solution of a system of linear equations. If the system is fully determined, clear pictures are obtained. Even for an underdetermined system (low number of projections) reasonable pictures are reconstructed, but then picture artefacts and convergence problems occur increasingly. (orig.) With 37 figs [de

  17. An Implementation of Parallel and Networked Computing Schemes for the Real-Time Image Reconstruction Based on Electrical Tomography

    International Nuclear Information System (INIS)

    Park, Sook Hee

    2001-02-01

    This thesis implements and analyzes the parallel and networked computing libraries based on the multiprocessor computer architecture as well as networked computers, aiming at improving the computation speed of ET(Electrical Tomography) system which requires enormous CPU time in reconstructing the unknown internal state of the target object. As an instance of the typical tomography technology, ET partitions the cross-section of the target object into the tiny elements and calculates the resistivity of them with signal values measured at the boundary electrodes surrounding the surface of the object after injecting the predetermined current pattern through the object. The number of elements is determined considering the trade-off between the accuracy of the reconstructed image and the computation time. As the elements become more finer, the number of element increases, and the system can get the better image. However, the reconstruction time increases polynomially with the number of partitioned elements since the procedure consists of a number of time consuming matrix operations such as multiplication, inverse, pseudo inverse, Jacobian and so on. Consequently, the demand for improving computation speed via multiple processor grows indispensably. Moreover, currently released PCs can be stuffed with up to 4 CPUs interconnected to the shared memory while some operating systems enable the application process to benefit from such computer by allocating the threaded job to each CPU, resulting in concurrent processing. In addition, a networked computing or cluster computing environment is commonly available to almost every computer which contains communication protocol and is connected to local or global network. After partitioning the given job(numerical operation), each CPU or computer calculates the partial result independently, and the results are merged via common memory to produce the final result. It is desirable to adopt the commonly used library such as Matlab to

  18. Influence of Sinogram-Affirmed Iterative Reconstruction on Computed Tomography-Based Lung Volumetry and Quantification of Pulmonary Emphysema.

    Science.gov (United States)

    Baumueller, Stephan; Hilty, Regina; Nguyen, Thi Dan Linh; Weder, Walter; Alkadhi, Hatem; Frauenfelder, Thomas

    2016-01-01

    The purpose of this study was to evaluate the influence of sinogram-affirmed iterative reconstruction (SAFIRE) on quantification of lung volume and pulmonary emphysema in low-dose chest computed tomography compared with filtered back projection (FBP). Enhanced or nonenhanced low-dose chest computed tomography was performed in 20 patients with chronic obstructive pulmonary disease (group A) and in 20 patients without lung disease (group B). Data sets were reconstructed with FBP and SAFIRE strength levels 3 to 5. Two readers semiautomatically evaluated lung volumes and automatically quantified pulmonary emphysema, and another assessed image quality. Radiation dose parameters were recorded. Lung volume between FBP and SAFIRE 3 to 5 was not significantly different among both groups (all P > 0.05). When compared with those of FBP, total emphysema volume was significantly lower among reconstructions with SAFIRE 4 and 5 (mean difference, 0.56 and 0.79 L; all P emphysema is affected at higher strength levels.

  19. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  20. Orbital computed tomography for exophthalmos

    International Nuclear Information System (INIS)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo

    1987-01-01

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos

  1. Computed tomography of cerebrovascular accidents

    International Nuclear Information System (INIS)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin

    1989-01-01

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography

  2. Computed tomography of cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1989-10-15

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography.

  3. Orbital computed tomography for exophthalmos

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo [College of Medicine, Pusan National University, Busan (Korea, Republic of)

    1987-06-15

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos.

  4. Image quality in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Gerke, Oke; Thygesen, Jesper

    2018-01-01

    Background Computed tomography (CT) technology is rapidly evolving and software solution developed to optimize image quality and/or lower radiation dose. Purpose To investigate the influence of adaptive statistical iterative reconstruction (ASIR) at different radiation doses in coronary CT...

  5. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  6. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  7. Volume-based quantification using dual-energy computed tomography in the differentiation of thymic epithelial tumours: an initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Suyon; Hur, Jin; Im, Dong Jin; Suh, Young Joo; Hong, Yoo Jin; Lee, Hye-Jeong; Kim, Young Jin; Choi, Byoung Wook [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Seoul (Korea, Republic of); Han, Kyunghwa [Yonsei University College of Medicine, Yonsei Biomedical Research Institute, Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Seoul (Korea, Republic of); Kim, Dae Joon; Lee, Chang Young [Yonsei University College of Medicine, Department of Thoracic and Cardiovascular Surgery, Seoul (Korea, Republic of); Shin, Ha Young [Yonsei University College of Medicine, Department of Neurology, Seoul (Korea, Republic of)

    2017-05-15

    To investigate the diagnostic value of dual-energy computed tomography (DECT) in differentiating between low- and high-risk thymomas and thymic carcinomas. Our institutional review board approved this study, and patients provided informed consent. We prospectively enrolled 37 patients (20 males, mean age: 55.6 years) with thymic epithelial tumour. All patients underwent DECT. For quantitative analysis, two reviewers measured the following tumour parameters: CT attenuation value in contrast Hounsfield units (CHU), iodine-related HU and iodine concentration (mg/ml). Pathological results confirmed the final diagnosis. Of the 37 thymic tumours, 23 (62.2 %) were low-risk thymomas, five (13.5 %) were high-risk thymomas and nine (24.3 %) were thymic carcinomas. According to quantitative analysis, iodine-related HU and iodine concentration were significantly different among low-risk thymomas, high-risk thymomas and thymic carcinomas (median: 29.78 HU vs. 14.55 HU vs. 19.95 HU, p = 0.001 and 1.92 mg/ml vs. 0.99 mg/ml vs. 1.18 mg/ml, p < 0.001, respectively). DECT using a quantitative analytical method based on iodine concentration measurement can be used to differentiate among thymic epithelial tumours using single-phase scanning. (orig.)

  8. An Effective Approach of Teeth Segmentation within the 3D Cone Beam Computed Tomography Image Based on Deformable Surface Model

    Directory of Open Access Journals (Sweden)

    Xutang Zhang

    2016-01-01

    Full Text Available In order to extract the pixels of teeth from 3D Cone Beam Computed Tomography (CBCT image, in this paper, a novel 3D segmentation approach based on deformable surface mode is developed for 3D tooth model reconstruction. Different forces are formulated to handle the segmentation problem by using different strategies. First, the proposed method estimates the deformation force of vertex model by simulating the deformation process of a bubble under the action of internal pressure and external force field. To handle the blurry boundary, a “braking force” is proposed deriving from the 3D gradient information calculated by transforming the Sobel operator into three-dimension representation. In addition, a “border reinforcement” strategy is developed for handling the cases with complicate structures. Moreover, the proposed method combines affine cell image decomposition (ACID grid reparameterization technique to handle the unstable changes of topological structure and deformability during the deformation process. The proposed method was performed on 510 CBCT images. To validate the performance, the results were compared with those of two other well-studied methods. Experimental results show that the proposed approach had a good performance in handling the cases with complicate structures and blurry boundaries well, is effective to converge, and can successfully achieve the reconstruction task of various types of teeth in oral cavity.

  9. Molecular Imaging of Cancer Using X-ray Computed Tomography with Protease Targeted Iodinated Activity-Based Probes.

    Science.gov (United States)

    Gaikwad, Hanmant K; Tsvirkun, Darya; Ben-Nun, Yael; Merquiol, Emmanuelle; Popovtzer, Rachela; Blum, Galia

    2018-03-14

    X-ray computed tomography (CT) is a robust, precise, fast, and reliable imaging method that enables excellent spatial resolution and quantification of contrast agents throughout the body. However, CT is largely inadequate for molecular imaging applications due mainly to its low contrast sensitivity that forces the use of large concentrations of contrast agents for detection. To overcome this limitation, we generated a new class of iodinated nanoscale activity-based probes (IN-ABPs) that sufficiently accumulates at the target site by covalently binding cysteine cathepsins that are exceptionally highly expressed in cancer. The IN-ABPs are comprised of a short targeting peptide selective to specific cathepsins, an electrophilic moiety that allows activity-dependent covalent binding, and tags containing dendrimers with up to 48 iodine atoms. IN-ABPs selectively bind and inhibit activity of recombinant and intracellular cathepsin B, L, and S. We compared the in vivo kinetics, biodistribution, and tumor accumulation of IN-ABPs bearing 18 and 48 iodine atoms each, and their control counterparts lacking the targeting moiety. Here we show that although both IN-ABPs bind specifically to cathepsins within the tumor and produce detectable CT contrast, the 48-iodine bearing IN-ABP was found to be optimal with signals over 2.1-fold higher than its nontargeted counterpart. In conclusion, this study shows the synthetic feasibility and potential utility of IN-ABPs as potent contrast agents that enable molecular imaging of tumors using CT.

  10. Preclinical validation of automated dual-energy X-ray absorptiometry and computed tomography-based body composition measurements

    International Nuclear Information System (INIS)

    DEVRIESE, Joke; Pottel, Hans; BEELS, Laurence; VAN DE WIELE, Christophe; MAES, Alex; GHEYSENS, Olivier

    2016-01-01

    The aim of this study was to determine and validate a set of Hounsfield unit (HU) ranges to segment computed tomography (CT) images into tissue types and to test the validity of dual-energy X-ray absorptiometry (DXA) tissue segmentation on pure, unmixed porcine tissues. This preclinical prospective study was approved by the local ethical committee. Different quantities of porcine bone tissue (BT), lean tissue (LT) and adipose tissue (AT) were scanned using DXA and CT. Tissue type segmentation in DXA was performed via the standard clinical protocol and in CT through different sets of HU ranges. Percent coefficients of variation (%CV) were used to assess precision while % differences of observed masses were tested against zero using the Wilcoxon signed-rank Test. Total mass DXA measurements differ little but significantly (P=0.016) from true mass, while total mass CT measurements based on literature values show non-significant (P=0.69) differences of 1.7% and 2.0%. BT mass estimates with DXA differed more from true mass (median -78.2 to -75.8%) than other tissue types (median -11.3 to -8.1%). Tissue mass estimates with CT and literature HU ranges showed small differences from true mass for every tissue type (median -10.4 to 8.8%). The most suited method for automated tissue segmentation is CT and can become a valuable tool in quantitative nuclear medicine.

  11. Reduced radiation exposure to the mammary glands in thoracic computed tomography using organ-based tube-current modulation

    International Nuclear Information System (INIS)

    Munechika, Jiro; Ohgiya, Yoshimitsu; Gokan, Takehiko; Hashimoto, Toshi; Iwai, Tsugunori

    2013-01-01

    Organ-based tube-current modulation has been used to reduce radiation exposure to specific organs. However, there are no reports yet published on reducing radiation exposure in clinical cases. In this study, we assessed the reduction in radiation exposure to the mammary glands during thoracic computed tomography (CT) using X-CARE. In a phantom experiment, the use of X-CARE reduced radiation exposure at the midline of the precordial region by a maximum of 45.1%. In our corresponding clinical study, CT was performed using X-CARE in 15 patients, and without X-CARE in another 15. Compared to the non-X-CARE group, radiation exposure was reduced in the X-CARE group at the midline of the precordial region by 22.3% (P 0.05). X-CARE thus reduced radiation exposure at the midline of the precordial region and allowed us to obtain consistent CT values without increasing noise. However, this study revealed increases in radiation exposure at the lateral sides of the breasts. It is conceivable that patients' breasts were laterally displaced by gravity under the standard thoracic imaging conditions. Further studies that consider factors such as body size and adjustment of imaging conditions may be needed in the future. (author)

  12. Non-Contrast Computed Tomography Scan Based Parameters of Ureteric Stones Affecting the Outcome of Extracorporeal Shock Wave Lithotripsy

    Science.gov (United States)

    Ayaz Khan, Mohammad; Waqas Iqbal, Muhammad; Akbar, Mian Khalid; Saqib, Imad-ud-din; Akhter, Saeed

    2017-01-01

    Objective  To compare the non-contrast computed tomography (NCCT) scan-based parameters of ureteric stones affecting the outcome of extracorporeal shock wave lithotripsy (ESWL). Materials and methods We retrospectively evaluated the pre-procedure NCCT of 74 patients who had ESWL for solitary ureteric calculi of 5-20 mm in diameter. We assessed the age, sex, basal metabolic index (BMI), laterality, location, presence of double 'J' (DJ) stent, skin to stone distance (SSD), stone maximum diameter, Hounsfield unit (HU), Hounsfield density (HD), area, and volume. All those who had no stone on follow-up imaging within 30 days were declared successful while those who had residual stone were declared failures. Results The overall success rate was 78% (58/74). Sixty (81.1%) patients were male. The success of ESWL was correlated with lower SSD, Hounsfield units (HU) and Hounsfield density (HD). However, in multivariate analysis, SSD, Hounsfield unit, and stone area showed correlation with success of procedure but Hounsfield density failed to show correlation. The success rate in patients with stone HU 1000 were 93.9%, 69%, and 58.3%, respectively. Patients with lower BMI (30 kg/m2) and higher HD (>76 HU/mm). Conclusion BMI, SSD, stone Hounsfield units and Hounsfield unit density were strong predictors of outcome of ESWL for ureteric stone. PMID:28589076

  13. Evaluation of web-based instruction for anatomical interpretation in maxillofacial cone beam computed tomography

    NARCIS (Netherlands)

    Al-Rawi, W.T.; Jacobs, R.; Hassan, B.A.; Sanderink, G.; Scarfe, W.C.

    2007-01-01

    Objectives: To evaluate the effectiveness of a web-based instruction in the interpretation of anatomy in images acquired with maxillofacial cone beam CT (CBCT). Methods: An interactive web-based education course for the interpretation of craniofacial CBCT images was recently developed at our

  14. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  15. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  16. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  17. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  18. LBP-based penalized weighted least-squares approach to low-dose cone-beam computed tomography reconstruction

    Science.gov (United States)

    Ma, Ming; Wang, Huafeng; Liu, Yan; Zhang, Hao; Gu, Xianfeng; Liang, Zhengrong

    2014-03-01

    Cone-beam computed tomography (CBCT) has attracted growing interest of researchers in image reconstruction. The mAs level of the X-ray tube current, in practical application of CBCT, is mitigated in order to reduce the CBCT dose. The lowering of the X-ray tube current, however, results in the degradation of image quality. Thus, low-dose CBCT image reconstruction is in effect a noise problem. To acquire clinically acceptable quality of image, and keep the X-ray tube current as low as achievable in the meanwhile, some penalized weighted least-squares (PWLS)-based image reconstruction algorithms have been developed. One representative strategy in previous work is to model the prior information for solution regularization using an anisotropic penalty term. To enhance the edge preserving and noise suppressing in a finer scale, a novel algorithm combining the local binary pattern (LBP) with penalized weighted leastsquares (PWLS), called LBP-PWLS-based image reconstruction algorithm, is proposed in this work. The proposed LBP-PWLS-based algorithm adaptively encourages strong diffusion on the local spot/flat region around a voxel and less diffusion on edge/corner ones by adjusting the penalty for cost function, after the LBP is utilized to detect the region around the voxel as spot, flat and edge ones. The LBP-PWLS-based reconstruction algorithm was evaluated using the sinogram data acquired by a clinical CT scanner from the CatPhan® 600 phantom. Experimental results on the noiseresolution tradeoff measurement and other quantitative measurements demonstrated its feasibility and effectiveness in edge preserving and noise suppressing in comparison with a previous PWLS reconstruction algorithm.

  19. Impact of Computed Tomography Image Quality on Image-Guided Radiation Therapy Based on Soft Tissue Registration

    International Nuclear Information System (INIS)

    Morrow, Natalya V.; Lawton, Colleen A.; Qi, X. Sharon; Li, X. Allen

    2012-01-01

    Purpose: In image-guided radiation therapy (IGRT), different computed tomography (CT) modalities with varying image quality are being used to correct for interfractional variations in patient set-up and anatomy changes, thereby reducing clinical target volume to the planning target volume (CTV-to-PTV) margins. We explore how CT image quality affects patient repositioning and CTV-to-PTV margins in soft tissue registration-based IGRT for prostate cancer patients. Methods and Materials: Four CT-based IGRT modalities used for prostate RT were considered in this study: MV fan beam CT (MVFBCT) (Tomotherapy), MV cone beam CT (MVCBCT) (MVision; Siemens), kV fan beam CT (kVFBCT) (CTVision, Siemens), and kV cone beam CT (kVCBCT) (Synergy; Elekta). Daily shifts were determined by manual registration to achieve the best soft tissue agreement. Effect of image quality on patient repositioning was determined by statistical analysis of daily shifts for 136 patients (34 per modality). Inter- and intraobserver variability of soft tissue registration was evaluated based on the registration of a representative scan for each CT modality with its corresponding planning scan. Results: Superior image quality with the kVFBCT resulted in reduced uncertainty in soft tissue registration during IGRT compared with other image modalities for IGRT. The largest interobserver variations of soft tissue registration were 1.1 mm, 2.5 mm, 2.6 mm, and 3.2 mm for kVFBCT, kVCBCT, MVFBCT, and MVCBCT, respectively. Conclusions: Image quality adversely affects the reproducibility of soft tissue-based registration for IGRT and necessitates a careful consideration of residual uncertainties in determining different CTV-to-PTV margins for IGRT using different image modalities.

  20. Impact of Computed Tomography Image Quality on Image-Guided Radiation Therapy Based on Soft Tissue Registration

    Energy Technology Data Exchange (ETDEWEB)

    Morrow, Natalya V.; Lawton, Colleen A. [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Qi, X. Sharon [Department of Radiation Oncology, University of Colorado Denver, Denver, Colorado (United States); Li, X. Allen, E-mail: ali@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States)

    2012-04-01

    Purpose: In image-guided radiation therapy (IGRT), different computed tomography (CT) modalities with varying image quality are being used to correct for interfractional variations in patient set-up and anatomy changes, thereby reducing clinical target volume to the planning target volume (CTV-to-PTV) margins. We explore how CT image quality affects patient repositioning and CTV-to-PTV margins in soft tissue registration-based IGRT for prostate cancer patients. Methods and Materials: Four CT-based IGRT modalities used for prostate RT were considered in this study: MV fan beam CT (MVFBCT) (Tomotherapy), MV cone beam CT (MVCBCT) (MVision; Siemens), kV fan beam CT (kVFBCT) (CTVision, Siemens), and kV cone beam CT (kVCBCT) (Synergy; Elekta). Daily shifts were determined by manual registration to achieve the best soft tissue agreement. Effect of image quality on patient repositioning was determined by statistical analysis of daily shifts for 136 patients (34 per modality). Inter- and intraobserver variability of soft tissue registration was evaluated based on the registration of a representative scan for each CT modality with its corresponding planning scan. Results: Superior image quality with the kVFBCT resulted in reduced uncertainty in soft tissue registration during IGRT compared with other image modalities for IGRT. The largest interobserver variations of soft tissue registration were 1.1 mm, 2.5 mm, 2.6 mm, and 3.2 mm for kVFBCT, kVCBCT, MVFBCT, and MVCBCT, respectively. Conclusions: Image quality adversely affects the reproducibility of soft tissue-based registration for IGRT and necessitates a careful consideration of residual uncertainties in determining different CTV-to-PTV margins for IGRT using different image modalities.

  1. Comparison of computed tomography dose reporting software

    International Nuclear Information System (INIS)

    Abdullah, A.; Sun, Z.; Pongnapang, N.; Ng, K. H.

    2008-01-01

    Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover (Germany)), ImPACT CT Patients Dosimetry Calculator (version 0.99x, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck (Germany)), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen (Germany)) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen (Germany)) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly. (authors)

  2. The dynamic micro computed tomography at SSRF

    Science.gov (United States)

    Chen, R.; Xu, L.; Du, G.; Deng, B.; Xie, H.; Xiao, T.

    2018-05-01

    Synchrotron radiation micro-computed tomography (SR-μCT) is a critical technique for quantitative characterizing the 3D internal structure of samples, recently the dynamic SR-μCT has been attracting vast attention since it can evaluate the three-dimensional structure evolution of a sample. A dynamic μCT method, which is based on monochromatic beam, was developed at the X-ray Imaging and Biomedical Application Beamline at Shanghai Synchrotron Radiation Facility, by combining the compressed sensing based CT reconstruction algorithm and hardware upgrade. The monochromatic beam based method can achieve quantitative information, and lower dose than the white beam base method in which the lower energy beam is absorbed by the sample rather than contribute to the final imaging signal. The developed method is successfully used to investigate the compression of the air sac during respiration in a bell cricket, providing new knowledge for further research on the insect respiratory system.

  3. Newly defined landmarks for a three-dimensionally based cephalometric analysis: a retrospective cone-beam computed tomography scan review.

    Science.gov (United States)

    Lee, Moonyoung; Kanavakis, Georgios; Miner, R Matthew

    2015-01-01

    To identify two novel three-dimensional (3D) cephalometric landmarks and create a novel three-dimensionally based anteroposterior skeletal measurement that can be compared with traditional two-dimensional (2D) cephalometric measurements in patients with Class I and Class II skeletal patterns. Full head cone-beam computed tomography (CBCT) scans of 100 patients with all first molars in occlusion were obtained from a private practice. InvivoDental 3D (version 5.1.6, Anatomage, San Jose, Calif) was used to analyze the CBCT scans in the sagittal and axial planes to create new landmarks and a linear 3D analysis (M measurement) based on maxillary and mandibular centroids. Independent samples t-test was used to compare the mean M measurement to traditional 2D cephalometric measurements, ANB and APDI. Interexaminer and intraexaminer reliability were evaluated using 2D and 3D scatterplots. The M measurement, ANB, and APDI could statistically differentiate between patients with Class I and Class II skeletal patterns (P < .001). The M measurement exhibited a correlation coefficient (r) of -0.79 and 0.88 with APDI and ANB, respectively. The overall centroid landmarks and the M measurement combine 2D and 3D methods of imaging; the measurement itself can distinguish between patients with Class I and Class II skeletal patterns and can serve as a potential substitute for ANB and APDI. The new three-dimensionally based landmarks and measurements are reliable, and there is great potential for future use of 3D analyses for diagnosis and research.

  4. Timing of computed tomography-based postimplant assessment following permanent transperineal prostate brachytherapy

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Bice, William S.; Kiefer, Eric J.; Prete, James J.

    1998-01-01

    Purpose: To establish the rate of resolution of prostatic edema following transperineal interstitial permanent prostate brachytherapy, and to determine the results and impact of timing of the postimplant assessment on the dose-volume relationship. Methods and Materials: A series of 19 consecutive patients with early-stage adenocarcinoma of the prostate receiving transperineal interstitial permanent prostate brachytherapy, were enrolled in this study. Twelve received 125 I and seven received 103 Pd. Postoperative assessment included a computed tomographic (CT) scan on postoperative days 1, 8, 30, 90, and 180. On each occasion, CT scans were performed on a GE helical unit at 3-mm abutting slices, 15-cm field of view. Prostate volumes were outlined on CT scans by a single clinician. Following digitization of the volumes and radioactive sources, volumes and dose-volume histograms were calculated. The prostate volume encompassed by the 80% and 100% reference isodose volumes was calculated. Results: Preimplant transrectal ultrasound determined volumes varied from 17.5 to 38.6 cc (median 27.9 cc). Prostate volumes previously defined on 40 randomly selected postimplant CT scans were compared in a blinded fashion to a second CT-derived volume and ranged from -32% to +24%. The Pearson correlation coefficient for prostate CT volume reproducibility was 0.77 (p < 0.03). CT scan-determined volume performed on postoperative day 1 was an average of 41.4% greater than the volume determined by preimplant ultrasound. Significant decreases in average volume were seen during the first month postoperatively. Average volume decreased 14% from day 1 to day 8, 10% from day 8 to day 30, 3% from day 30 to day 90, and 2% thereafter. Coverage of the prostate volume by the 80% isodose volume increased from 85.6% on postoperative day 1 to 92.2% on postoperative day 180. The corresponding increase in the 100% reference dose coverage of the prostate volume ranged from 73.1% to 83.3% between

  5. Statistical-techniques-based computer-aided diagnosis (CAD) using texture feature analysis: application in computed tomography (CT) imaging to fatty liver disease

    International Nuclear Information System (INIS)

    Chung, Woon-Kwan; Park, Hyong-Hu; Im, In-Chul; Lee, Jae-Seung; Goo, Eun-Hoe; Dong, Kyung-Rae

    2012-01-01

    This paper proposes a computer-aided diagnosis (CAD) system based on texture feature analysis and statistical wavelet transformation technology to diagnose fatty liver disease with computed tomography (CT) imaging. In the target image, a wavelet transformation was performed for each lesion area to set the region of analysis (ROA, window size: 50 x 50 pixels) and define the texture feature of a pixel. Based on the extracted texture feature values, six parameters (average gray level, average contrast, relative smoothness, skewness, uniformity, and entropy) were determined to calculate the recognition rate for a fatty liver. In addition, a multivariate analysis of the variance (MANOVA) method was used to perform a discriminant analysis to verify the significance of the extracted texture feature values and the recognition rate for a fatty liver. According to the results, each texture feature value was significant for a comparison of the recognition rate for a fatty liver (p < 0.05). Furthermore, the F-value, which was used as a scale for the difference in recognition rates, was highest in the average gray level, relatively high in the skewness and the entropy, and relatively low in the uniformity, the relative smoothness and the average contrast. The recognition rate for a fatty liver had the same scale as that for the F-value, showing 100% (average gray level) at the maximum and 80% (average contrast) at the minimum. Therefore, the recognition rate is believed to be a useful clinical value for the automatic detection and computer-aided diagnosis (CAD) using the texture feature value. Nevertheless, further study on various diseases and singular diseases will be needed in the future.

  6. Computed tomography of intraventricular hemorrhage

    International Nuclear Information System (INIS)

    Cho, Bum Shin; Shin, Kyoung Hee; Hahm, Chang Kok

    1982-01-01

    Computed tomography (CT) is a new non-invasive diagnostic imaging method, which has ability to differentiate C.S.F., hematoma, and even edematous brain from normal brain tissue. Prior to the introduction of the CT, the diagnosis of the intraventricular hemorrhage in living patients was difficult and was confirmed by surgery of autopsy. Intracranial hemorrhages are visible on the CT with density higher than brain tissue in acute phase. CT is an accurate method for detecting of intraventricular hemorrhage including detection of nature, location, amount, and associated changes. CT is also useful as a guidance and in the evaluation of fate of the hematomas by easily performable follow up studies. The causes of the intraventricular hemorrhages are hypertension, rupture of aneurysm, arteriovenous malformation, head trauma, brain tumor, and others. This study included evaluation of CT of 69 patients who show the high density in cerebral ventricular system during the period of 31 months from Feb. 1979 to Aug. 1981 in the Department of Radiology, College of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 69 patient was broad ranging from 1 month to 80 years. 28% of patients were in the 6th decade. The mate to female ratio was 2 : 1. 2. The consciousness of patients at CT study: Those were conscious in 11 cases, stuporous in 41 cases and unconscious in 17 cases. 3. The causes of intraventricular hemorrhages were hypertension in 28 cases, head trauma in 12 cases, aneurysm in 4 cases, tumor in 2 cases and others in 23 cases. 4. 9 cases showed intraventricular hematomas only, other 60 cases showed associated intracranial hematomas: Those were intracerebral hematomas in 53 cases including 30 cases of basal ganglial and thalamic hematomas, subarachnoid hemorrhage in 17 cases, epidural hematomas in 3 cases, and subdural hematomas in 2 cases. 5. All cases of the intraventricular hematomas except one sowed hematoma in the lateral

  7. Computed tomography in subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Lee, Seung Ro; Chang, Kee Hyun; Choi, Byung Ihn; Han, Man Chung; Sim, Bo Sung

    1981-01-01

    Computed Tomography has become increasingly important diagnostic method as the initial examination in the diagnosis of subarachnoid hemorrhage with direct detection of extravasated blood in basal cistern and cortical sulci. Furthermore, CT provides better and exact visualization of the presence, localization, extent and degree of intracerebral, intraventricular and subdural hemorrhage, infarction, hydrocephalus and rebleeding which may be associated with subarachnoid hemorrhage, and also could detect the causative lesions with contrast enhancement in many cases. The purpose of the paper is to describe the CT findings of subarachnoid hemorrhage due to various causes and to evaluate the diagnostic accuracy of CT in subarachnoid hemorrhage. Authors analysed a total of 153 cases with subarachnoid hemorrhage confirmed by lumbar puncture at Seoul National University Hospital from March 1979 to April 1981, with special emphasis on CT findings. All of the cases took CT scan and 125 cases of them angiography. The results are as follows: 1. Most prevalent age group was 4th to 6th decades (78%). The ratio of male to female was 1.1: 1. 2. Of 125 cases with angiography, aneurysm was a major cause (68%). Others were arterio-venous malformation (9.6%), Moya-moya disease (4%) and unknown (18.4%). 3. Of all 153 cases with CT scan, hemorrhage was demonstrated in 98 cases (64.1%); SAH in 72 cases (47.1%), ICH in 65 cases (42.5%), IVH in 34 cases (22.2%) and SDH in 1 case (0.7%). SAH combined with ICH was a major group (34.7%) in SAH. Detection rate of SAH was 68.3% within the first 7 days and 5.8% after 7 dyas. 4. In aneurysms, SAH was detected in 60 of 85 cases (70.6%); 88.1% within the first 7 dyas and 5.6% after 7 dyas. Anterior communicating artery was the most common site of the aneurysms (40%), in which detection rate of SAH was 100% within the first 7 days. SAH was combined with ICH in 38.3%. 5. On CT, SAH of unilateral Sylvian fissure was pathognomonic for ruptured MCA

  8. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  9. Principle of diffraction enhanced imaging (DEI) and computed tomography based on DEI method

    International Nuclear Information System (INIS)

    Zhu Peiping; Huang Wanxia; Yuan Qingxi; Wang Junyue; Zheng Xin; Shu Hang; Chen Bo; Liu Yijin; Li Enrong; Wu Ziyu; Yu Jian

    2006-01-01

    In the first part of this article a more general DEI equation was derived using simple concepts. Not only does the new DEI equation explain all the problems that can be done by the DEI equation proposed by Chapman, but also explains the problem that can not be explained with the old DEI equation, such as the noise background caused by the small angle scattering reflected by the analyzer. In the second part, a DEI-PI-CT formula has been proposed and the contour contrast caused by the extinction of refraction beam has been qualitatively explained, and then based on the work of Ando's group two formulae of refraction CT with DEI method has been proposed. Combining one refraction CT formula proposed by Dilmanian with the two refraction CT formulae proposed by us, the whole framework of CT algorithm can be made to reconstruct three components of the gradient of refractive index. (authors)

  10. Non-tuberculous mycobacterial lung disease: diagnosis based on computed tomography of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Nakwon; Han, Sung Koo; Yim, Jae-Joon [Seoul National University College of Medicine, Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, 101 Daehak-Ro, Jongno-Gu, Seoul (Korea, Republic of); Lee, Chang Hyun; Lee, Hyun-Ju [Seoul National University College of Medicine, Department of Radiology, and Institute of Radiation Medicine, Seoul (Korea, Republic of); Kang, Young Ae [Yonsei University College of Medicine, Division of Pulmonology, Department of Internal Medicine, Severance Hospital, Institute of Chest Diseases, Seoul (Korea, Republic of); Lee, Jae Ho [Seoul National University Bundang Hospital, Department of Internal Medicine, Seongnam, Gyeonggi-do (Korea, Republic of)

    2016-12-15

    To elucidate the accuracy and inter-observer agreement of non-tuberculous mycobacterial lung disease (NTM-LD) diagnosis based on chest CT findings. Two chest radiologists and two pulmonologists interpreted chest CTs of 66 patients with NTM-LD, 33 with pulmonary tuberculosis and 33 with non-cystic fibrosis bronchiectasis. These observers selected one of these diagnoses for each case without knowing any clinical information except age and sex. Sensitivity and specificity were calculated according to degree of observer confidence. Inter-observer agreement was assessed using Fleiss' κ values. Multiple logistic regression was performed to elucidate which radiological features led to the correct diagnosis. The sensitivity of NTM-LD diagnosis was 56.4 % (95 % CI 47.9-64.7) and specificity 80.3 % (73.1-86.0). The specificity of NTM-LD diagnosis increased with confidence: 44.4 % (20.5-71.3) for possible, 77.4 % (67.4-85.0) for probable, 95.2 % (87.2-98.2) for definite (P < 0.001) diagnoses. Inter-observer agreement for NTM-LD diagnosis was moderate (κ = 0.453). Tree-in-bud pattern (adjusted odds ratio [aOR] 6.24, P < 0.001), consolidation (aOR 1.92, P = 0.036) and atelectasis (aOR 3.73, P < 0.001) were associated with correct NTM-LD diagnoses, whereas presence of pleural effusion (aOR 0.05, P < 0.001) led to false diagnoses. NTM-LD diagnosis based on chest CT findings is specific but not sensitive. (orig.)

  11. Evaluation of Functional Marrow Irradiation Based on Skeletal Marrow Composition Obtained Using Dual-Energy Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Magome, Taiki [Department of Radiological Sciences, Faculty of Health Sciences, Komazawa University, Tokyo (Japan); Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Froelich, Jerry [Department of Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Takahashi, Yutaka [Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Department of Radiation Oncology, Osaka University, Osaka (Japan); Arentsen, Luke [Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Holtan, Shernan; Verneris, Michael R. [Blood and Marrow Transplant Program, University of Minnesota, Minneapolis, Minnesota (United States); Brown, Keenan [Mindways Software Inc, Austin, Texas (United States); Haga, Akihiro; Nakagawa, Keiichi [Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Holter Chakrabarty, Jennifer L. [College of Medicine, Oklahoma Health Sciences Center, Oklahoma City, Oklahoma (United States); Giebel, Sebastian [Department of Bone Marrow Transplantation, Comprehensive Cancer Center M. Curie-Sklodowska Memorial Institute, Gliwice (Poland); Wong, Jeffrey [Department of Radiation Oncology, Beckman Research Institute, City of Hope, Duarte, California (United States); Dusenbery, Kathryn [Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Storme, Guy [Department of Radiotherapy, Universitair Ziekenhuis Brussel, Brussels (Belgium); Hui, Susanta K., E-mail: shui@coh.org [Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Department of Radiation Oncology, Beckman Research Institute, City of Hope, Duarte, California (United States)

    2016-11-01

    Purpose: To develop an imaging method to characterize and map marrow composition in the entire skeletal system, and to simulate differential targeted marrow irradiation based on marrow composition. Methods and Materials: Whole-body dual energy computed tomography (DECT) images of cadavers and leukemia patients were acquired, segmented to separate bone marrow components, namely, bone, red marrow (RM), and yellow marrow (YM). DECT-derived marrow fat fraction was validated using histology of lumbar vertebrae obtained from cadavers. The fractions of RM (RMF = RM/total marrow) and YMF were calculated in each skeletal region to assess the correlation of marrow composition with sites and ages. Treatment planning was simulated to target irradiation differentially at a higher dose (18 Gy) to either RM or YM and a lower dose (12 Gy) to the rest of the skeleton. Results: A significant correlation between fat fractions obtained from DECT and cadaver histology samples was observed (r=0.861, P<.0001, Pearson). The RMF decreased in the head, neck, and chest was significantly inversely correlated with age but did not show any significant age-related changes in the abdomen and pelvis regions. Conformity of radiation to targets (RM, YM) was significantly dependent on skeletal sites. The radiation exposure was significantly reduced (P<.05, t test) to organs at risk (OARs) in RM and YM irradiation compared with standard total marrow irradiation (TMI). Conclusions: Whole-body DECT offers a new imaging technique to visualize and measure skeletal-wide marrow composition. The DECT-based treatment planning offers volumetric and site-specific precise radiation dosimetry of RM and YM, which varies with aging. Our proposed method could be used as a functional compartment of TMI for further targeted radiation to specific bone marrow environment, dose escalation, reduction of doses to OARs, or a combination of these factors.

  12. Micro-computed tomography (CT) based assessment of dental regenerative therapy in the canine mandible model

    Science.gov (United States)

    Khobragade, P.; Jain, A.; Setlur Nagesh, S. V.; Andreana, S.; Dziak, R.; Sunkara, S. K.; Sunkara, S.; Bednarek, D. R.; Rudin, S.; Ionita, C. N.

    2015-03-01

    High-resolution 3D bone-tissue structure measurements may provide information critical to the understanding of the bone regeneration processes and to the bone strength assessment. Tissue engineering studies rely on such nondestructive measurements to monitor bone graft regeneration area. In this study, we measured bone yield, fractal dimension and trabecular thickness through micro-CT slices for different grafts and controls. Eight canines underwent surgery to remove a bone volume (defect) in the canine's jaw at a total of 44 different locations. We kept 11 defects empty for control and filled the remaining ones with three regenerative materials; NanoGen (NG), a FDA-approved material (n=11), a novel NanoCalcium Sulfate (NCS) material (n=11) and NCS alginate (NCS+alg) material (n=11). After a minimum of four and eight weeks, the canines were sacrificed and the jaw samples were extracted. We used a custombuilt micro-CT system to acquire the data volume and developed software to measure the bone yield, fractal dimension and trabecular thickness. The software used a segmentation algorithm based on histograms derived from volumes of interest indicated by the operator. Using bone yield and fractal dimension as indices we are able to differentiate between the control and regenerative material (p<0.005). Regenerative material NCS showed an average 63.15% bone yield improvement over the control sample, NCS+alg showed 55.55% and NanoGen showed 37.5%. The bone regeneration process and quality of bone were dependent upon the position of defect and time period of healing. This study presents one of the first quantitative comparisons using non-destructive Micro-CT analysis for bone regenerative material in a large animal with a critical defect model. Our results indicate that Micro-CT measurement could be used to monitor invivo bone regeneration studies for greater regenerative process understanding.

  13. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Shirota, Go; Maeda, Eriko; Namiki, Yoko; Bari, Razibul; Abe, Osamu [The University of Tokyo, Department of Radiology, Graduate School of Medicine, Tokyo (Japan); Ino, Kenji [The University of Tokyo Hospital, Imaging Center, Tokyo (Japan); Torigoe, Rumiko [Toshiba Medical Systems, Tokyo (Japan)

    2017-10-15

    Full iterative reconstruction algorithm is available, but its diagnostic quality in pediatric cardiac CT is unknown. To compare the imaging quality of two algorithms, full and hybrid iterative reconstruction, in pediatric cardiac CT. We included 49 children with congenital cardiac anomalies who underwent cardiac CT. We compared quality of images reconstructed using the two algorithms (full and hybrid iterative reconstruction) based on a 3-point scale for the delineation of the following anatomical structures: atrial septum, ventricular septum, right atrium, right ventricle, left atrium, left ventricle, main pulmonary artery, ascending aorta, aortic arch including the patent ductus arteriosus, descending aorta, right coronary artery and left main trunk. We evaluated beam-hardening artifacts from contrast-enhancement material using a 3-point scale, and we evaluated the overall image quality using a 5-point scale. We also compared image noise, signal-to-noise ratio and contrast-to-noise ratio between the algorithms. The overall image quality was significantly higher with full iterative reconstruction than with hybrid iterative reconstruction (3.67±0.79 vs. 3.31±0.89, P=0.0072). The evaluation scores for most of the gross structures were higher with full iterative reconstruction than with hybrid iterative reconstruction. There was no significant difference between full and hybrid iterative reconstruction for the presence of beam-hardening artifacts. Image noise was significantly lower in full iterative reconstruction, while signal-to-noise ratio and contrast-to-noise ratio were significantly higher in full iterative reconstruction. The diagnostic quality was superior in images with cardiac CT reconstructed with electrocardiogram-gated full iterative reconstruction. (orig.)

  14. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction

    International Nuclear Information System (INIS)

    Shirota, Go; Maeda, Eriko; Namiki, Yoko; Bari, Razibul; Abe, Osamu; Ino, Kenji; Torigoe, Rumiko

    2017-01-01

    Full iterative reconstruction algorithm is available, but its diagnostic quality in pediatric cardiac CT is unknown. To compare the imaging quality of two algorithms, full and hybrid iterative reconstruction, in pediatric cardiac CT. We included 49 children with congenital cardiac anomalies who underwent cardiac CT. We compared quality of images reconstructed using the two algorithms (full and hybrid iterative reconstruction) based on a 3-point scale for the delineation of the following anatomical structures: atrial septum, ventricular septum, right atrium, right ventricle, left atrium, left ventricle, main pulmonary artery, ascending aorta, aortic arch including the patent ductus arteriosus, descending aorta, right coronary artery and left main trunk. We evaluated beam-hardening artifacts from contrast-enhancement material using a 3-point scale, and we evaluated the overall image quality using a 5-point scale. We also compared image noise, signal-to-noise ratio and contrast-to-noise ratio between the algorithms. The overall image quality was significantly higher with full iterative reconstruction than with hybrid iterative reconstruction (3.67±0.79 vs. 3.31±0.89, P=0.0072). The evaluation scores for most of the gross structures were higher with full iterative reconstruction than with hybrid iterative reconstruction. There was no significant difference between full and hybrid iterative reconstruction for the presence of beam-hardening artifacts. Image noise was significantly lower in full iterative reconstruction, while signal-to-noise ratio and contrast-to-noise ratio were significantly higher in full iterative reconstruction. The diagnostic quality was superior in images with cardiac CT reconstructed with electrocardiogram-gated full iterative reconstruction. (orig.)

  15. Variation in the human ribs geometrical properties and mechanical response based on X-ray computed tomography images resolution.

    Science.gov (United States)

    Perz, Rafał; Toczyski, Jacek; Subit, Damien

    2015-01-01

    Computational models of the human body are commonly used for injury prediction in automobile safety research. To create these models, the geometry of the human body is typically obtained from segmentation of medical images such as computed tomography (CT) images that have a resolution between 0.2 and 1mm/pixel. While the accuracy of the geometrical and structural information obtained from these images depend greatly on their resolution, the effect of image resolution on the estimation of the ribs geometrical properties has yet to be established. To do so, each of the thirty-four sections of ribs obtained from a Post Mortem Human Surrogate (PMHS) was imaged using three different CT modalities: standard clinical CT (clinCT), high resolution clinical CT (HRclinCT), and microCT. The images were processed to estimate the rib cross-section geometry and mechanical properties, and the results were compared to those obtained from the microCT images by computing the 'deviation factor', a metric that quantifies the relative difference between results obtained from clinCT and HRclinCT to those obtained from microCT. Overall, clinCT images gave a deviation greater than 100%, and were therefore deemed inadequate for the purpose of this study. HRclinCT overestimated the rib cross-sectional area by 7.6%, the moments of inertia by about 50%, and the cortical shell area by 40.2%, while underestimating the trabecular area by 14.7%. Next, a parametric analysis was performed to quantify how the variations in the estimate of the geometrical properties affected the rib predicted mechanical response under antero-posterior loading. A variation of up to 45% for the predicted peak force and up to 50% for the predicted stiffness was observed. These results provide a quantitative estimate of the sensitivity of the response of the FE model to the resolution of the images used to generate it. They also suggest that a correction factor could be derived from the comparison between microCT and

  16. Quantitative Assessment of Optical Coherence Tomography Imaging Performance with Phantom-Based Test Methods And Computational Modeling

    Science.gov (United States)

    Agrawal, Anant

    Optical coherence tomography (OCT) is a powerful medical imaging modality that uniquely produces high-resolution cross-sectional images of tissue using low energy light. Its clinical applications and technological capabilities have grown substantially since its invention about twenty years ago, but efforts have been limited to develop tools to assess performance of OCT devices with respect to the quality and content of acquired images. Such tools are important to ensure information derived from OCT signals and images is accurate and consistent, in order to support further technology development, promote standardization, and benefit public health. The research in this dissertation investigates new physical and computational models which can provide unique insights into specific performance characteristics of OCT devices. Physical models, known as phantoms, are fabricated and evaluated in the interest of establishing standardized test methods to measure several important quantities relevant to image quality. (1) Spatial resolution is measured with a nanoparticle-embedded phantom and model eye which together yield the point spread function under conditions where OCT is commonly used. (2) A multi-layered phantom is constructed to measure the contrast transfer function along the axis of light propagation, relevant for cross-sectional imaging capabilities. (3) Existing and new methods to determine device sensitivity are examined and compared, to better understand the detection limits of OCT. A novel computational model based on the finite-difference time-domain (FDTD) method, which simulates the physics of light behavior at the sub-microscopic level within complex, heterogeneous media, is developed to probe device and tissue characteristics influencing the information content of an OCT image. This model is first tested in simple geometric configurations to understand its accuracy and limitations, then a highly realistic representation of a biological cell, the retinal

  17. Computed tomography of cartilaginous tumours

    International Nuclear Information System (INIS)

    Marincek, B.; Triller, J.; Robotti, G.; Gumppenberg, S. von

    1984-01-01

    The compound tomography (CT) morphology of cartilaginous tumors and the utility of CT in their diagnostic work-up is presented on the basis of 19 cases. CT provided unique informations regarding definition of tumor extent and tumor relationship to adjacent structures particularly in the axial skeleton. CT has diminished the indications for angiography in cartilaginous tumors. (orig.) [de

  18. Computed tomographic findings in dogs with head trauma and development of a novel prognostic computed tomography-based scoring system.

    Science.gov (United States)

    Chai, Orit; Peery, Dana; Bdolah-Abram, Tali; Moscovich, Efrat; Kelmer, Efrat; Klainbart, Sigal; Milgram, Joshua; Shamir, Merav H

    2017-09-01

    OBJECTIVE To characterize CT findings and outcomes in dogs with head trauma and design a prognostic scale. ANIMALS 27 dogs admitted to the Koret School Veterinary Teaching Hospital within 72 hours after traumatic head injury that underwent CT imaging of the head. PROCEDURES Data were extracted from medical records regarding dog signalment, history, physical and neurologic examination findings, and modified Glasgow coma scale scores. All CT images were retrospectively evaluated by a radiologist unaware of dog status. Short-term (10 days after trauma) and long-term (≥ 6 months after trauma) outcomes were determined, and CT findings and other variables were analyzed for associations with outcome. A prognostic CT-based scale was developed on the basis of the results. RESULTS Cranial vault fractures, parenchymal abnormalities, or both were identified via CT in 24 of 27 (89%) dogs. Three (11%) dogs had only facial bone fractures. Intracranial hemorrhage was identified in 16 (59%) dogs, cranial vault fractures in 15 (56%), midline shift in 14 (52%), lateral ventricle asymmetry in 12 (44%), and hydrocephalus in 7 (26%). Hemorrhage and ventricular asymmetry were significantly and negatively associated with short- and long-term survival, respectively. The developed 7-point prognostic scale included points for hemorrhage, midline shift or lateral ventricle asymmetry, cranial vault fracture, and depressed fracture (1 point each) and infratentorial lesion (3 points). CONCLUSIONS AND CLINICAL RELEVANCE The findings reported here may assist in determining prognoses for other dogs with head trauma. The developed scale may be useful for outcome assessment of dogs with head trauma; however, it must be validated before clinical application.

  19. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  20. TH-CD-206-12: Image-Based Motion Estimation for Plaque Visualization in Coronary Computed Tomography Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X; Sisniega, A; Zbijewski, W; Stayman, J [Johns Hopkins University, Balitmore, MD (United States); Contijoch, F; McVeigh, E [University of California, San Diego, San Diego, CA (United States)

    2016-06-15

    Purpose: Visualization and quantification of coronary artery calcification and atherosclerotic plaque benefits from coronary artery motion (CAM) artifact elimination. This work applies a rigid linear motion model to a Volume of Interest (VoI) for estimating motion estimation and compensation of image degradation in Coronary Computed Tomography Angiography (CCTA). Methods: In both simulation and testbench experiments, translational CAM was generated by displacement of the imaging object (i.e. simulated coronary artery and explanted human heart) by ∼8 mm, approximating the motion of a main coronary branch. Rotation was assumed to be negligible. A motion degraded region containing a calcification was selected as the VoI. Local residual motion was assumed to be rigid and linear over the acquisition window, simulating motion observed during diastasis. The (negative) magnitude of the image gradient of the reconstructed VoI was chosen as the motion estimation objective and was minimized with Covariance Matrix Adaptation Evolution Strategy (CMAES). Results: Reconstruction incorporated the estimated CAM yielded signification recovery of fine calcification structures as well as reduced motion artifacts within the selected local region. The compensated reconstruction was further evaluated using two image similarity metrics, the structural similarity index (SSIM) and Root Mean Square Error (RMSE). At the calcification site, the compensated data achieved a 3% increase in SSIM and a 91.2% decrease in RMSE in comparison with the uncompensated reconstruction. Conclusion: Results demonstrate the feasibility of our image-based motion estimation method exploiting a local rigid linear model for CAM compensation. The method shows promising preliminary results for the application of such estimation in CCTA. Further work will involve motion estimation of complex motion corrupted patient data acquired from clinical CT scanner.

  1. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    International Nuclear Information System (INIS)

    Karakas, Hakki Muammer; Celbis, Osman; Harma, Ahmet; Alicioglu, Banu

    2011-01-01

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 ± 14.9 years) and 43 women (41.1 ± 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 ± 12.6 mm (77-138 mm) in men and 104.7 ± 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  2. Visual vs Fully Automatic Histogram-Based Assessment of Idiopathic Pulmonary Fibrosis (IPF) Progression Using Sequential Multidetector Computed Tomography (MDCT)

    Science.gov (United States)

    Colombi, Davide; Dinkel, Julien; Weinheimer, Oliver; Obermayer, Berenike; Buzan, Teodora; Nabers, Diana; Bauer, Claudia; Oltmanns, Ute; Palmowski, Karin; Herth, Felix; Kauczor, Hans Ulrich; Sverzellati, Nicola

    2015-01-01

    Objectives To describe changes over time in extent of idiopathic pulmonary fibrosis (IPF) at multidetector computed tomography (MDCT) assessed by semi-quantitative visual scores (VSs) and fully automatic histogram-based quantitative evaluation and to test the relationship between these two methods of quantification. Methods Forty IPF patients (median age: 70 y, interquartile: 62-75 years; M:F, 33:7) that underwent 2 MDCT at different time points with a median interval of 13 months (interquartile: 10-17 months) were retrospectively evaluated. In-house software YACTA quantified automatically lung density histogram (10th-90th percentile in 5th percentile steps). Longitudinal changes in VSs and in the percentiles of attenuation histogram were obtained in 20 untreated patients and 20 patients treated with pirfenidone. Pearson correlation analysis was used to test the relationship between VSs and selected percentiles. Results In follow-up MDCT, visual overall extent of parenchymal abnormalities (OE) increased in median by 5 %/year (interquartile: 0 %/y; +11 %/y). Substantial difference was found between treated and untreated patients in HU changes of the 40th and of the 80th percentiles of density histogram. Correlation analysis between VSs and selected percentiles showed higher correlation between the changes (Δ) in OE and Δ 40th percentile (r=0.69; phistogram analysis at one year follow-up of IPF patients, whether treated or untreated: Δ 40th percentile might reflect the change in overall extent of lung abnormalities, notably of ground-glass pattern; furthermore Δ 80th percentile might reveal the course of reticular opacities. PMID:26110421

  3. Management of computed tomography-detected pneumothorax in patients with blunt trauma: experience from a community-based hospital

    Science.gov (United States)

    Hefny, Ashraf F; Kunhivalappil, Fathima T; Matev, Nikolay; Avila, Norman A; Bashir, Masoud O; Abu-Zidan, Fikri M

    2018-01-01

    INTRODUCTION Diagnoses of pneumothorax, especially occult pneumothorax, have increased as the use of computed tomography (CT) for imaging trauma patients becomes near-routine. However, the need for chest tube insertion remains controversial. We aimed to study the management of pneumothorax detected on CT among patients with blunt trauma, including the decision for tube thoracostomy, in a community-based hospital. METHODS Chest CT scans of patients with blunt trauma treated at Al Rahba Hospital, Abu Dhabi, United Arab Emirates, from October 2010 to October 2014 were retrospectively studied. Variables studied included demography, mechanism of injury, endotracheal intubation, pneumothorax volume, chest tube insertion, Injury Severity Score, hospital length of stay and mortality. RESULTS CT was performed in 703 patients with blunt trauma. Overall, pneumothorax was detected on CT for 74 (10.5%) patients. Among the 65 patients for whom pneumothorax was detected before chest tube insertion, 25 (38.5%) needed chest tube insertion, while 40 (61.5%) did not. Backward stepwise likelihood regression showed that independent factors that significantly predicted chest tube insertion were endotracheal intubation (p = 0.01), non-United Arab Emirates nationality (p = 0.01) and pneumothorax volume (p = 0.03). The receiver operating characteristic curve showed that the best pneumothorax volume that predicted chest tube insertion was 30 mL. CONCLUSION Chest tube was inserted in less than half of the patients with blunt trauma for whom pneumothorax was detected on CT. Pneumothorax volume should be considered in decision-making regarding chest tube insertion. Conservative treatment may be sufficient for pneumothorax of volume < 30 mL. PMID:28741012

  4. Energy-angle correlation correction algorithm for monochromatic computed tomography based on Thomson scattering X-ray source

    Science.gov (United States)

    Chi, Zhijun; Du, Yingchao; Huang, Wenhui; Tang, Chuanxiang

    2017-12-01

    The necessity for compact and relatively low cost x-ray sources with monochromaticity, continuous tunability of x-ray energy, high spatial coherence, straightforward polarization control, and high brightness has led to the rapid development of Thomson scattering x-ray sources. To meet the requirement of in-situ monochromatic computed tomography (CT) for large-scale and/or high-attenuation materials based on this type of x-ray source, there is an increasing demand for effective algorithms to correct the energy-angle correlation. In this paper, we take advantage of the parametrization of the x-ray attenuation coefficient to resolve this problem. The linear attenuation coefficient of a material can be decomposed into a linear combination of the energy-dependent photoelectric and Compton cross-sections in the keV energy regime without K-edge discontinuities, and the line integrals of the decomposition coefficients of the above two parts can be determined by performing two spectrally different measurements. After that, the line integral of the linear attenuation coefficient of an imaging object at a certain interested energy can be derived through the above parametrization formula, and monochromatic CT can be reconstructed at this energy using traditional reconstruction methods, e.g., filtered back projection or algebraic reconstruction technique. Not only can monochromatic CT be realized, but also the distributions of the effective atomic number and electron density of the imaging object can be retrieved at the expense of dual-energy CT scan. Simulation results validate our proposal and will be shown in this paper. Our results will further expand the scope of application for Thomson scattering x-ray sources.

  5. Management of computed tomography-detected pneumothorax in patients with blunt trauma: experience from a community-based hospital.

    Science.gov (United States)

    Hefny, Ashraf F; Kunhivalappil, Fathima T; Matev, Nikolay; Avila, Norman A; Bashir, Masoud O; Abu-Zidan, Fikri M

    2018-03-01

    Diagnoses of pneumothorax, especially occult pneumothorax, have increased as the use of computed tomography (CT) for imaging trauma patients becomes near-routine. However, the need for chest tube insertion remains controversial. We aimed to study the management of pneumothorax detected on CT among patients with blunt trauma, including the decision for tube thoracostomy, in a community-based hospital. Chest CT scans of patients with blunt trauma treated at Al Rahba Hospital, Abu Dhabi, United Arab Emirates, from October 2010 to October 2014 were retrospectively studied. Variables studied included demography, mechanism of injury, endotracheal intubation, pneumothorax volume, chest tube insertion, Injury Severity Score, hospital length of stay and mortality. CT was performed in 703 patients with blunt trauma. Overall, pneumothorax was detected on CT for 74 (10.5%) patients. Among the 65 patients for whom pneumothorax was detected before chest tube insertion, 25 (38.5%) needed chest tube insertion, while 40 (61.5%) did not. Backward stepwise likelihood regression showed that independent factors that significantly predicted chest tube insertion were endotracheal intubation (p = 0.01), non-United Arab Emirates nationality (p = 0.01) and pneumothorax volume (p = 0.03). The receiver operating characteristic curve showed that the best pneumothorax volume that predicted chest tube insertion was 30 mL. Chest tube was inserted in less than half of the patients with blunt trauma for whom pneumothorax was detected on CT. Pneumothorax volume should be considered in decision-making regarding chest tube insertion. Conservative treatment may be sufficient for pneumothorax of volume < 30 mL. Copyright: © Singapore Medical Association.

  6. Internal structures of scaffold-free 3D cell cultures visualized by synchrotron radiation-based micro-computed tomography

    Science.gov (United States)

    Saldamli, Belma; Herzen, Julia; Beckmann, Felix; Tübel, Jutta; Schauwecker, Johannes; Burgkart, Rainer; Jürgens, Philipp; Zeilhofer, Hans-Florian; Sader, Robert; Müller, Bert

    2008-08-01

    Recently the importance of the third dimension in cell biology has been better understood, resulting in a re-orientation towards three-dimensional (3D) cultivation. Yet adequate tools for their morphological characterization have to be established. Synchrotron radiation-based micro computed tomography (SRμCT) allows visualizing such biological systems with almost isotropic micrometer resolution, non-destructively. We have applied SRμCT for studying the internal morphology of human osteoblast-derived, scaffold-free 3D cultures, termed histoids. Primary human osteoblasts, isolated from femoral neck spongy bone, were grown as 2D culture in non-mineralizing osteogenic medium until a rather thick, multi-cellular membrane was formed. This delicate system was intentionally released to randomly fold itself. The folded cell cultures were grown to histoids of cubic milli- or centimeter size in various combinations of mineralizing and non-mineralizing osteogenic medium for a total period of minimum 56 weeks. The SRμCT-measurements were performed in the absorption contrast mode at the beamlines BW 2 and W 2 (HASYLAB at DESY, Hamburg, Germany), operated by the GKSS-Research Center. To investigate the entire volume of interest several scans were performed under identical conditions and registered to obtain one single dataset of each sample. The histoids grown under different conditions exhibit similar external morphology of globular or ovoid shape. The SRμCT-examination revealed the distinctly different morphological structures inside the histoids. One obtains details of the histoids that permit to identify and select the most promising slices for subsequent histological characterization.

  7. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Precht, H.; Kitslaar, P.H.; Broersen, A.; Gerke, O.; Dijkstra, J.; Thygesen, J.; Egstrup, K.; Lambrechtsen, J.

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model-based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) images on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods: Three patients had three independent dose reduced CCTA performed and reconstructed with 30% ASIR (CTDI vol at 6.7 mGy), 60% ASIR (CTDI vol 4.3 mGy) and Veo (CTDI vol at 1.9 mGy). Coronary plaque analysis was performed for each measured CCTA volumes, plaque burden and intensities. Results: Plaque volume and plaque burden show a decreasing tendency from ASIR to Veo as median volume for ASIR is 314 mm 3 and 337 mm 3 –252 mm 3 for Veo and plaque burden is 42% and 44% for ASIR to 39% for Veo. The lumen and vessel volume decrease slightly from 30% ASIR to 60% ASIR with 498 mm 3 –391 mm 3 for lumen volume and vessel volume from 939 mm 3 to 830 mm 3 . The intensities did not change overall between the different reconstructions for either lumen or plaque. Conclusion: We found a tendency of decreasing plaque volumes and plaque burden but no change in intensities with the use of low dose Veo CCTA (1.9 mGy) compared to dose reduced ASIR CCTA (6.7 mGy & 4.3 mGy), although more studies are warranted. - Highlights: • Veo decrease plaque volumes and plaque burden using low-dose CCTA. • Moving from ASIR 30%, ASIR 60% to Veo did not appear to influence the plaque intensities. • Studies including larger sample size are needed to investigate the effect on plaque.

  8. A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

    International Nuclear Information System (INIS)

    Cai, C.; Rodet, T.; Mohammad-Djafari, A.; Legoupil, S.

    2013-01-01

    Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also

  9. Investigation of four-dimensional computed tomography-based pulmonary ventilation imaging in patients with emphysematous lung regions

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tokihiro; Loo, Billy W Jr; Keall, Paul J [Department of Radiation Oncology, Stanford University School of Medicine, 875 Blake Wilbur Dr, Stanford, CA 94305-5847 (United States); Kabus, Sven; Lorenz, Cristian; Von Berg, Jens; Blaffert, Thomas [Department of Digital Imaging, Philips Research Europe, Roentgenstrasse 24-26, D-22335 Hamburg (Germany); Klinder, Tobias, E-mail: Tokihiro@stanford.edu [Clinical Informatics, Interventional, and Translational Solutions, Philips Research North America, Briarcliff Manor, NY 10510 (United States)

    2011-04-07

    A pulmonary ventilation imaging technique based on four-dimensional (4D) computed tomography (CT) has advantages over existing techniques. However, physiologically accurate 4D-CT ventilation imaging has not been achieved in patients. The purpose of this study was to evaluate 4D-CT ventilation imaging by correlating ventilation with emphysema. Emphysematous lung regions are less ventilated and can be used as surrogates for low ventilation. We tested the hypothesis: 4D-CT ventilation in emphysematous lung regions is significantly lower than in non-emphysematous regions. Four-dimensional CT ventilation images were created for 12 patients with emphysematous lung regions as observed on CT, using a total of four combinations of two deformable image registration (DIR) algorithms: surface-based (DIR{sup sur}) and volumetric (DIR{sup vol}), and two metrics: Hounsfield unit (HU) change (V{sub HU}) and Jacobian determinant of deformation (V{sub Jac}), yielding four ventilation image sets per patient. Emphysematous lung regions were detected by density masking. We tested our hypothesis using the one-tailed t-test. Visually, different DIR algorithms and metrics yielded spatially variant 4D-CT ventilation images. The mean ventilation values in emphysematous lung regions were consistently lower than in non-emphysematous regions for all the combinations of DIR algorithms and metrics. V{sub HU} resulted in statistically significant differences for both DIR{sup sur} (0.14 {+-} 0.14 versus 0.29 {+-} 0.16, p = 0.01) and DIR{sup vol} (0.13 {+-} 0.13 versus 0.27 {+-} 0.15, p < 0.01). However, V{sub Jac} resulted in non-significant differences for both DIR{sup sur} (0.15 {+-} 0.07 versus 0.17 {+-} 0.08, p = 0.20) and DIR{sup vol} (0.17 {+-} 0.08 versus 0.19 {+-} 0.09, p = 0.30). This study demonstrated the strong correlation between the HU-based 4D-CT ventilation and emphysema, which indicates the potential for HU-based 4D-CT ventilation imaging to achieve high physiologic accuracy. A

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which rotates around the patient. The computer that processes the imaging information and monitor are located in ... follows a spiral path. A special computer program processes this series of pictures, or slices of the ...

  12. Design and analysis of a tendon-based computed tomography-compatible robot with remote center of motion for lung biopsy.

    Science.gov (United States)

    Yang, Yunpeng; Jiang, Shan; Yang, Zhiyong; Yuan, Wei; Dou, Huaisu; Wang, Wei; Zhang, Daguang; Bian, Yuan

    2017-04-01

    Nowadays, biopsy is a decisive method of lung cancer diagnosis, whereas lung biopsy is time-consuming, complex and inaccurate. So a computed tomography-compatible robot for rapid and precise lung biopsy is developed in this article. According to the actual operation process, the robot is divided into two modules: 4-degree-of-freedom position module for location of puncture point is appropriate for patient's almost all positions and 3-degree-of-freedom tendon-based orientation module with remote center of motion is compact and computed tomography-compatible to orientate and insert needle automatically inside computed tomography bore. The workspace of the robot surrounds patient's thorax, and the needle tip forms a cone under patient's skin. A new error model of the robot based on screw theory is proposed in view of structure error and actuation error, which are regarded as screw motions. Simulation is carried out to verify the precision of the error model contrasted with compensation via inverse kinematics. The results of insertion experiment on specific phantom prove the feasibility of the robot with mean error of 1.373 mm in laboratory environment, which is accurate enough to replace manual operation.

  13. Practical techniques for pediatric computed tomography

    International Nuclear Information System (INIS)

    Fitz, C.R.; Harwood-Nash, D.C.; Kirks, D.R.; Kaufman, R.A.; Berger, P.E.; Kuhn, J.P.; Siegel, M.J.

    1983-01-01

    Dr. Donald Kirks has assembled this section on Practical Techniques for Pediatric Computed Tomography. The material is based on a presentation in the Special Interest session at the 25th Annual Meeting of the Society for Pediatric Radiology in New Orleans, Louisiana, USA in 1982. Meticulous attention to detail and technique is required to ensure an optimal CT examination. CT techniques specifically applicable to infants and children have not been disseminated in the radiology literature and in this respect it may rightly be observed that ''the child is not a small adult''. What follows is a ''cookbook'' prepared by seven participants and it is printed in Pediatric Radiology, in outline form, as a statement of individual preferences for pediatric CT techniques. This outline gives concise explanation of techniques and permits prompt dissemination of information. (orig.)

  14. Teleradiology for emergency cranial computed tomography

    International Nuclear Information System (INIS)

    Stranzinger, E.; Treumann, T.C.; Dreier, D.; Allgayer, B.

    2003-01-01

    Purpose: We report our experience with the teleradiologic service provided by a center hospital (CH) for emergency cranial computed tomography (CCT) in two regional hospitals (RH) during a 12-month period. The clinical and economic impact of teleradiology will be discussed as well as the acceptance by the clinicians of the regional hospitals. Material and Methods: In 2001, 213 CT-scans in 202 patients were performed and reported using teleradiology. Teleradiologic and final medical diagnosis were analysed by the medical reports. The transferral of the patients to a CH and their further treatment were checked. The referring physicians in the RH were questionnaired about the teleradiological support. Results: 18 (9%) patients had to be urgently transferred to a CH based on the CT findings in the teleradiological reports. 24 patients (11%) were transferred to a center hospital during further treatment. 80% of patients were treated in the RH. (orig.) [de

  15. System Matrix Analysis for Computed Tomography Imaging

    Science.gov (United States)

    Flores, Liubov; Vidal, Vicent; Verdú, Gumersindo

    2015-01-01

    In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data. PMID:26575482

  16. Computer tomography of intracranial tumours and hematomas

    International Nuclear Information System (INIS)

    Tans, J.T.J.

    1978-01-01

    The value of computed tomography (CT) for the diagnosis of intracranial tumors and hematomas was investigated in a retrospective study comprising 220 patients. All C.T.scans are reviewed and described in detail. To assess the diagnostic accuracy, the original interpretation of the C.T.scans was compared with that of conventional neuroradiological and neurophysiological examinations. The aspect on C.T. of the various types of tumors and hematomas proved to vary widely and specific features were seldom seen. This holds particularly for the malignant tumors. Benign tumors such as meningeomas, adenomas and neurilemmomas showed a rather easily identifiable and almost identical picture of the C.T.scan, and diagnosis had to be based mainly on differences in localization. The hematomas, with the exception of the older intracerebral ones, showed the most characteristic C.T.abnormalities. (Auth.)

  17. Computed tomography of the abnormal thymus

    International Nuclear Information System (INIS)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion

  18. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  19. Pre- and post-radiotherapy computed tomography in laryngeal cancer: imaging-based prediction of local failure

    International Nuclear Information System (INIS)

    Pameijer, Frank A.; Hermans, Robert; Mancuso, Anthony A.; Mendenhall, William M.; Parsons, James T.; Stringer, Scott P.; Kubilis, Paul S.; Tinteren, Harm van

    1999-01-01

    Purpose: To determine if pre-radiotherapy (RT) and/or post-radiotherapy computed tomography (CT) can predict local failure in patients with laryngeal carcinoma treated with definitive RT. Methods and Materials: The pre- and post-RT CT examinations of 59 patients (T3 glottic carcinoma [n = 30] and T1-T4 supraglottic carcinoma [n = 29]) were reviewed. For each patient, the first post-RT CT study between 1 and 6 months after irradiation was used. All patients were treated with definitive hyperfractionated twice-daily continuous-course irradiation to a total dose of 6,720-7,920 cGy, and followed-up clinically for at least 2 years after completion of RT. Local control was defined as absence of primary tumor recurrence and a functioning larynx. On the pre-treatment CT study, each tumor was assigned a high-or low-risk profile for local failure after RT. The post-RT CT examinations were evaluated for post-treatment changes using a three-point post-RT CT-score: 1 = expected post-RT changes; 2 = focal mass with a maximal diameter of 1 cm, or < 50% estimated tumor volume reduction. Results: The local control rates at 2 years post-RT based on pre-treatment CT evaluation were 88% for low pre-treatment risk profile patients (95% CI: 66-96%) and 34% (95% CI: 19-50%) for high pre-treatment risk profile patients (risk ratio 6.583; 95% CI: 2.265-9.129; p = 0.0001). Based on post-treatment CT, the local control rates at 2 years post-RT were 94% for score 1, 67% for score 2, and 10% for score 3 (risk ratio 4.760; 95% CI: 2.278-9.950 p 0.0001). Post-RT CT scores added significant information to the pre-treatment risk profiles on prognosis. Conclusions: Pre-treatment CT risk profiles, as well as post-RT CT evaluation can identify patients, irradiated for laryngeal carcinomas, at high risk for developing local failure. When the post-RT CT score is available, it proves to be an even better prognosticator than the pre-treatment CT-risk profile

  20. Substantial dose reduction in modern multi-slice spiral computed tomography (MSCT)-guided craniofacial and skull base surgery

    International Nuclear Information System (INIS)

    Widmann, G.; Fasser, M.; Jaschke, W.; Bale, R.; Schullian, P.; Zangerl, A.; Puelacher, W.; Kral, F.; Riechelmann, H.

    2012-01-01

    Purpose: Reduction of the radiation exposure involved in image-guided craniofacial and skull base surgery is an important goal. The purpose was to evaluate the influence of low-dose protocols in modern multi-slice spiral computed tomography (MSCT) on target registration errors (TREs). Materials and Methods: An anthropomorphic skull phantom with target markers at the craniofacial bone and the anterior skull base was scanned in Sensation Open (40-slice), LightSpeed VCT (64-slice) and Definition Flash (128-slice). Identical baseline protocols (BP) at 120 kV/100 mAs were compared to the following low-dose protocols (LD) in care dose/dose modulation: (LD-I) 100 kV/35ref. mAs, (LD-II) 80 kV/40 - 41ref. mAs, and (LD-III) 80 kV/15 - 17ref. mAs. CTDIvol and DLP were obtained. TREs using an optical navigation system were calculated for all scanners and protocols. Results were statistically analyzed in SPSS and compared for significant differences (p ≤ 0.05). Results: CTDIvol for the Sensation Open/LightSpeed VCT/Definition Flash showed: (BP) 22.24 /32.48 /14.32 mGy; (LD-I) 4.61 /3.52 /1,62 mGy; (LD-II) 3.15 /2.01 /0.87 mGy; and (LD-III) na/0.76 /0.76 mGy. Differences between the BfS (Bundesamt fuer Strahlenschutz) reference CTDIvol of 9 mGy and the lowest CTDIvol were approximately 3-fold for Sensation Open, and 12-fold for the LightSpeed VCT and Definition Flash. A total of 33 registrations and 297 TRE measurements were performed. In all MSCT scanners, the TREs did not significantly differ between the low-dose and the baseline protocols. Conclusion: Low-dose protocols in modern MSCT provided substantial dose reductions without significant influence on TRE and should be strongly considered in image-guided surgery. (orig.)

  1. Micro-computed tomography-based phenotypic approaches in embryology: procedural artifacts on assessments of embryonic craniofacial growth and development

    Directory of Open Access Journals (Sweden)

    Logan C Cairine

    2010-02-01

    Full Text Available Abstract Background Growing demand for three dimensional (3D digital images of embryos for purposes of phenotypic assessment drives implementation of new histological and imaging techniques. Among these micro-computed tomography (μCT has recently been utilized as an effective and practical method for generating images at resolutions permitting 3D quantitative analysis of gross morphological attributes of developing tissues and organs in embryonic mice. However, histological processing in preparation for μCT scanning induces changes in organ size and shape. Establishing normative expectations for experimentally induced changes in size and shape will be an important feature of 3D μCT-based phenotypic assessments, especially if quantifying differences in the values of those parameters between comparison sets of developing embryos is a primary aim. Toward that end, we assessed the nature and degree of morphological artifacts attending μCT scanning following use of common fixatives, using a two dimensional (2D landmark geometric morphometric approach to track the accumulation of distortions affecting the embryonic head from the native, uterine state through to fixation and subsequent scanning. Results Bouin's fixation reduced average centroid sizes of embryonic mouse crania by approximately 30% and substantially altered the morphometric shape, as measured by the shift in Procrustes distance, from the unfixed state, after the data were normalized for naturally occurring shape variation. Subsequent μCT scanning produced negligible changes in size but did appear to reduce or even reverse fixation-induced random shape changes. Mixtures of paraformaldehyde + glutaraldehyde reduced average centroid sizes by 2-3%. Changes in craniofacial shape progressively increased post-fixation. Conclusions The degree to which artifacts are introduced in the generation of random craniofacial shape variation relates to the degree of specimen dehydration during the

  2. Micro-computed tomography-based phenotypic approaches in embryology: procedural artifacts on assessments of embryonic craniofacial growth and development.

    Science.gov (United States)

    Schmidt, Eric J; Parsons, Trish E; Jamniczky, Heather A; Gitelman, Julian; Trpkov, Cvett; Boughner, Julia C; Logan, C Cairine; Sensen, Christoph W; Hallgrímsson, Benedikt

    2010-02-17

    Growing demand for three dimensional (3D) digital images of embryos for purposes of phenotypic assessment drives implementation of new histological and imaging techniques. Among these micro-computed tomography (microCT) has recently been utilized as an effective and practical method for generating images at resolutions permitting 3D quantitative analysis of gross morphological attributes of developing tissues and organs in embryonic mice. However, histological processing in preparation for microCT scanning induces changes in organ size and shape. Establishing normative expectations for experimentally induced changes in size and shape will be an important feature of 3D microCT-based phenotypic assessments, especially if quantifying differences in the values of those parameters between comparison sets of developing embryos is a primary aim. Toward that end, we assessed the nature and degree of morphological artifacts attending microCT scanning following use of common fixatives, using a two dimensional (2D) landmark geometric morphometric approach to track the accumulation of distortions affecting the embryonic head from the native, uterine state through to fixation and subsequent scanning. Bouin's fixation reduced average centroid sizes of embryonic mouse crania by approximately 30% and substantially altered the morphometric shape, as measured by the shift in Procrustes distance, from the unfixed state, after the data were normalized for naturally occurring shape variation. Subsequent microCT scanning produced negligible changes in size but did appear to reduce or even reverse fixation-induced random shape changes. Mixtures of paraformaldehyde + glutaraldehyde reduced average centroid sizes by 2-3%. Changes in craniofacial shape progressively increased post-fixation. The degree to which artifacts are introduced in the generation of random craniofacial shape variation relates to the degree of specimen dehydration during the initial fixation. Fixation methods that

  3. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    Science.gov (United States)

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  4. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  5. Computed tomography of sacro-iliac joints

    International Nuclear Information System (INIS)

    Miquel, A.; Laredo, J.D.

    1995-01-01

    Actual technologies to explore sacro-iliac joints are conventional radiography, computed tomography , scintigraphy and nuclear magnetic resonance imaging. Standards films are sufficient, except in beginning sacro-iliac septic inflammations where the computed tomography is superior. Two problems are generally posed for the radiologist, to differentiate a septic arthritis from a rheumatic pathology An other problem in diagnosis is to make the difference between a degenerative arthropathy (which does not need a further investigation) and an infectious rheumatic pathology where more exploration is necessary. 28 refs., 3 tabs., 13 figs

  6. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2014-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... examined the content, data quality, and research potential of the WDHR-CCTR. METHODS: We retrieved 2008-2012 data to examine the 1) content; 2) completeness of procedure registration using the Danish National Patient Registry as reference; 3) completeness of variable registration comparing observed vs...

  7. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  8. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  9. Computed tomography in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki

    1990-01-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.)

  10. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches.

    Science.gov (United States)

    Nada, Rania M; Maal, Thomas J J; Breuning, K Hero; Bergé, Stefaan J; Mostafa, Yehya A; Kuijpers-Jagtman, Anne Marie

    2011-02-09

    Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16) for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27) for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... so that the x-ray beam follows a spiral path. A special computer program processes this series ... Sometimes ultrasound is substituted for CT as a method of imaging in these procedures in children. A ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ... diabetes, kidney disease or thyroid problems. Any of these conditions may influence the decision on whether contrast ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  16. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  17. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tokihiro, E-mail: toyamamoto@ucdavis.edu [Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California 95817 (United States); Kent, Michael S.; Wisner, Erik R. [Department of Surgical and Radiological Sciences, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Johnson, Lynelle R.; Stern, Joshua A. [Department of Medicine and Epidemiology, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Qi, Lihong [Department of Public Health Sciences, University of California Davis, Davis, California 95616 (United States); Fujita, Yukio [Department of Radiation Oncology, Tokai University, Isehara, Kanagawa 259-1193 (Japan); Boone, John M. [Department of Radiology, University of California Davis School of Medicine, Sacramento, California 95817 (United States)

    2016-07-15

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  18. Generation of realistic virtual nodules based on three-dimensional spatial resolution in lung computed tomography: A pilot phantom study.

    Science.gov (United States)

    Narita, Akihiro; Ohkubo, Masaki; Murao, Kohei; Matsumoto, Toru; Wada, Shinichi

    2017-10-01

    The aim of this feasibility study using phantoms was to propose a novel method for obtaining computer-generated realistic virtual nodules in lung computed tomography (CT). In the proposed methodology, pulmonary nodule images obtained with a CT scanner are deconvolved with the point spread function (PSF) in the scan plane and slice sensitivity profile (SSP) measured for the scanner; the resultant images are referred to as nodule-like object functions. Next, by convolving the nodule-like object function with the PSF and SSP of another (target) scanner, the virtual nodule can be generated so that it has the characteristics of the spatial resolution of the target scanner. To validate the methodology, the authors applied physical nodules of 5-, 7- and 10-mm-diameter (uniform spheres) included in a commercial CT test phantom. The nodule-like object functions were calculated from the sphere images obtained with two scanners (Scanner A and Scanner B); these functions were referred to as nodule-like object functions A and B, respectively. From these, virtual nodules were generated based on the spatial resolution of another scanner (Scanner C). By investigating the agreement of the virtual nodules generated from the nodule-like object functions A and B, the equivalence of the nodule-like object functions obtained from different scanners could be assessed. In addition, these virtual nodules were compared with the real (true) sphere images obtained with Scanner C. As a practical validation, five types of laboratory-made physical nodules with various complicated shapes and heterogeneous densities, similar to real lesions, were used. The nodule-like object functions were calculated from the images of these laboratory-made nodules obtained with Scanner A. From them, virtual nodules were generated based on the spatial resolution of Scanner C and compared with the real images of laboratory-made nodules obtained with Scanner C. Good agreement of the virtual nodules generated from

  19. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model.

    Science.gov (United States)

    Yamamoto, Tokihiro; Kent, Michael S; Wisner, Erik R; Johnson, Lynelle R; Stern, Joshua A; Qi, Lihong; Fujita, Yukio; Boone, John M

    2016-07-01

    Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. The mean TRE

  20. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    International Nuclear Information System (INIS)

    Yamamoto, Tokihiro; Kent, Michael S.; Wisner, Erik R.; Johnson, Lynelle R.; Stern, Joshua A.; Qi, Lihong; Fujita, Yukio; Boone, John M.

    2016-01-01

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  1. High resolution propagation-based imaging system for in vivo dynamic computed tomography of lungs in small animals

    Science.gov (United States)

    Preissner, M.; Murrie, R. P.; Pinar, I.; Werdiger, F.; Carnibella, R. P.; Zosky, G. R.; Fouras, A.; Dubsky, S.

    2018-04-01

    We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution of slightly below 50 μm at imaging rates of 30 Hz, and the ability to quantify material density differences of at least 3%. We benchmark our system against existing small animal pre-clinical CT scanners using a quality factor that combines spatial resolution, image noise, dose and scan time. In vivo 4DCT images obtained on our system demonstrate resolution of important features such as blood vessels and small airways, of which the smallest discernible were measured as 55–60 μm in cross section. Quantitative analysis of the images demonstrate regional differences in ventilation between injured and healthy lungs.

  2. 3D exemplar-based random walks for tooth segmentation from cone-beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Yuru, E-mail: peiyuru@cis.pku.edu.cn; Ai, Xingsheng; Zha, Hongbin [Department of Machine Intelligence, School of EECS, Peking University, Beijing 100871 (China); Xu, Tianmin [School of Stomatology, Stomatology Hospital, Peking University, Beijing 100081 (China); Ma, Gengyu [uSens, Inc., San Jose, California 95110 (United States)

    2016-09-15

    Purpose: Tooth segmentation is an essential step in acquiring patient-specific dental geometries from cone-beam computed tomography (CBCT) images. Tooth segmentation from CBCT images is still a challenging task considering the comparatively low image quality caused by the limited radiation dose, as well as structural ambiguities from intercuspation and nearby alveolar bones. The goal of this paper is to present and discuss the latest accomplishments in semisupervised tooth segmentation with adaptive 3D shape constraints. Methods: The authors propose a 3D exemplar-based random walk method of tooth segmentation from CBCT images. The proposed method integrates semisupervised label propagation and regularization by 3D exemplar registration. To begin with, the pure random walk method is to get an initial segmentation of the teeth, which tends to be erroneous because of the structural ambiguity of CBCT images. And then, as an iterative refinement, the authors conduct a regularization by using 3D exemplar registration, as well as label propagation by random walks with soft constraints, to improve the tooth segmentation. In the first stage of the iteration, 3D exemplars with well-defined topologies are adapted to fit the tooth contours, which are obtained from the random walks based segmentation. The soft constraints on voxel labeling are defined by shape-based foreground dentine probability acquired by the exemplar registration, as well as the appearance-based probability from a support vector machine (SVM) classifier. In the second stage, the labels of the volume-of-interest (VOI) are updated by the random walks with soft constraints. The two stages are optimized iteratively. Instead of the one-shot label propagation in the VOI, an iterative refinement process can achieve a reliable tooth segmentation by virtue of exemplar-based random walks with adaptive soft constraints. Results: The proposed method was applied for tooth segmentation of twenty clinically captured CBCT

  3. Quantitative analysis and prediction of regional lymph node status in rectal cancer based on computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Chunyan; Liu, Lizhi; Li, Li [Sun Yat-sen University, State Key Laboratory of Oncology in Southern China, Imaging Diagnosis and Interventional Center, Cancer Center, Guangzhou, Guangdong (China); Cai, Hongmin; Tian, Haiying [Sun Yat-Sen University, Department of Automation, School of Science Information and Technology, Guangzhou (China); Li, Liren [Sun Yat-sen University, State Key Laboratory of Oncology in Southern China, Department of Abdominal (colon and rectal) Surgery, Cancer Center, Guangzhou (China)

    2011-11-15

    To quantitatively evaluate regional lymph nodes in rectal cancer patients by using an automated, computer-aided approach, and to assess the accuracy of this approach in differentiating benign and malignant lymph nodes. Patients (228) with newly diagnosed rectal cancer, confirmed by biopsy, underwent enhanced computed tomography (CT). Patients were assigned to the benign node or malignant node group according to histopathological analysis of node samples. All CT-detected lymph nodes were segmented using the edge detection method, and seven quantitative parameters of each node were measured. To increase the prediction accuracy, a hierarchical model combining the merits of the support and relevance vector machines was proposed to achieve higher performance. Of the 220 lymph nodes evaluated, 125 were positive and 95 were negative for metastases. Fractal dimension obtained by the Minkowski box-counting approach was higher in malignant nodes than in benign nodes, and there was a significant difference in heterogeneity between metastatic and non-metastatic lymph nodes. The overall performance of the proposed model is shown to have accuracy as high as 88% using morphological characterisation of lymph nodes. Computer-aided quantitative analysis can improve the prediction of node status in rectal cancer. (orig.)

  4. Computed Tomography Study Of Complicated Bacterial Meningitis ...

    African Journals Online (AJOL)

    To monitor the structural intracranial complications of bacterial meningitis using computed tomography (CT) scan. Retrospective study of medical and radiological records of patients who underwent CT scan over a 4 year period. AUniversityTeachingHospital in a developing country. Thirty three patients with clinically and ...

  5. Computed tomography - old ideas and new technology

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik; Boas, F.E. [Stanford University, School of Medicine, Department of Radiology, Stanford, CA (United States)

    2011-03-15

    Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

  6. Computed tomography in the evaluation of trauma

    International Nuclear Information System (INIS)

    Federle, M.P.; Brant-Zawadzki, M.

    1982-01-01

    This book is intended to be the current standard for computed tomography in the evaluation of trauma. It summarizes two years of experience at San Francisco General Hospital. The book is organized into seven chapters, covering head, maxillofacial, laryngeal, spinal, chest, abdominal, acetabular, and pelvic trauma. Extremity trauma is not discussed

  7. Computed tomography (CT) and diastematomyelia's diagnosis

    International Nuclear Information System (INIS)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S.; Barros, A.P. de

    1982-01-01

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized. (Author) [pt

  8. Computed tomography evaluation of petrous bone fractures ...

    African Journals Online (AJOL)

    Background: Petrous bone trauma is the sequel of blunt head injury and can have life threatening complications resulting in immediate mortality. Early detection and good knowledge of the Computed Tomography (CT) findings ensure prompt treatment of both fractures and complications. Objective: To document the ...

  9. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  10. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...

  11. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  12. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  13. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  14. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...

  15. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...

  16. Investigation of measuring strategies in computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2011-01-01

    Computed tomography has entered the industrial world in 1980’s as a technique for non-destructive testing and has nowadays become a revolutionary tool for dimensional metrology, suitable for actual/nominal comparison and verification of geometrical and dimensional tolerances. This paper evaluates...

  17. Computed tomography in severe protein energy malnutrition.

    OpenAIRE

    Househam, K C; de Villiers, J F

    1987-01-01

    Computed tomography of the brain was performed on eight children aged 1 to 4 years with severe protein energy malnutrition. Clinical features typical of kwashiorkor were present in all the children studied. Severe cerebral atrophy or brain shrinkage according to standard radiological criteria was present in every case. The findings of this study suggest considerable cerebral insult associated with severe protein energy malnutrition.

  18. Computed tomography of the iliopsoas muscle

    International Nuclear Information System (INIS)

    Nino-Murcia, M.; Wechsler, R.J.; Brennan, R.E.

    1983-01-01

    Computed tomography (CT) is an ideal method for the imaging of the psoas muscle. The authors present 13 cases of patients with psoas abnormalities diagnosed by CT. The CT features of the different pathologic entities and comparison of CT with other imaging modalities are discussed. (orig.)

  19. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal

  20. Computer assisted tomography tandem and ovoids (CATTO): results of a 3D CT based assessment of bladder and rectal doses

    International Nuclear Information System (INIS)

    Gebara, Wade; Weeks, Ken; Hahn, Carol; Montana, Gustavo; Anscher, Mitchell

    1996-01-01

    Purpose: To compare bladder and rectal dose rates in tandem and ovoid applications using two different dosimetry systems: traditional orthogonal radiograph-based dosimetry (TORD) vs. computer assisted tomography tandem and ovoids dosimetry (CATTO). Materials and Methods: From August 1992 through February 1996, 22 patients with carcinoma of the uterine cervix received the brachytherapy component of their radiotherapy with a CT-compatible Fletcher-Suit-Delclos device. Three-dimensional (3D) anatomic reconstructions were created with axial CT images. Three-dimensional dose calculations were then performed, and the isodose map was superimposed on the 3D anatomic reconstructions. Maximum bladder (B max ) and rectal (R max ) dose rates were determined from the result of calculating the dose rate to each point on the 3D surface of those organs. Three-dimensional computer displays were also obtained to determine the anatomic positions of the largest dose. Additionally, orthogonal radiography, with contrast in a Foley catheter balloon and a radio-opaque rectal tube was used to define rectal and bladder points. The dose rates at these points were calculated using a commercial treatment planning system. The effect of the tungsten shielding was ignored in the TORD calculations, but included in the CATTO calculations. Bladder and rectal dose rates determined by each dosimetry system were compared. Results: The B max calculated using the CATTO system was higher in all 22 patients when compared with the TORD system. The average B max for the patients using TORD was 43.4 cGy/hr, as compared to 86.2 cGy/hr using the CATTO system (p = 0.0083). The location of B max on CATTO was never at the Foley bulb where the maximum bladder dose was calculated with TORD. It was located approximately 1 cm superior to the colpostats and just anterior to the tandem in (16(22)) patients. R max was higher in (17(22)) patients using the CATTO system when compared with TORD. The average R max using TORD

  1. Computed tomography of tuberculous meningitis

    International Nuclear Information System (INIS)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto

    1982-01-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis. (author)

  2. Misty mesentery: computed tomography findings

    International Nuclear Information System (INIS)

    Ahualli, Jorge; Mendez Uriburu, Luis; Ravera, Maria L.; Cikman, Pablo

    2008-01-01

    An alteration in the density of the mesenteric adipose tissue is often the principal clue of underlying mesenteric and bowel disease. The term 'Misty Mesentery' describes the computed tomographic appearance of mesenteric fat infiltrated by inflammatory cells, fluid (edema, lymph, and/or blood), tumor, and fibrosis. (author) [es

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... detectors rotate around the patient. At the same time, the examination table is moving through the scanner, so that the x-ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the body, to ...

  5. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    was not used. Autopsies were performed according to the Danish government's official guidelines. PMCT and autopsy findings were interpreted independent of each other. Diagnoses, including the cause of death and histology findings, were registered in a computer database (SPSS) together with information about...

  6. Computed tomography in Alexander's disease

    Energy Technology Data Exchange (ETDEWEB)

    Holland, I M; Kendall, B E

    1980-10-01

    Two cases of biopsy-proven Alexander's disease are described with computed tomographic changes which, in our experience and on survey of the literature, have not occurred in any other condition. Such changes in a child with a progressive condition consistent with Alexander's disease, strongly support the diagnosis.

  7. Computed tomography of limy bile

    International Nuclear Information System (INIS)

    Yamamoto, Shinichiro; Kimoto, Masatoshi; Gunge, Nobuharu; Sano, Kaizo; Yamashita, Sachiko; Hirano, Yutaka

    1983-01-01

    The computed tomographic appearance of three cases of limy bile was reported. The CT findings consist of uniform high density within gallbladder, niveau formation between limy bile and noncalcified bile. Sagittal reconstruction of CT images was especially useful in the differentiation of limy bile and gallstones. (author)

  8. Evaluation of computer-based computer tomography stratification against outcome models in connective tissue disease-related interstitial lung disease: a patient outcome study.

    Science.gov (United States)

    Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Brun, Anne Laure; Egashira, Ryoko; Karwoski, Ronald; Kokosi, Maria; Wells, Athol U; Hansell, David M

    2016-11-23

    To evaluate computer-based computer tomography (CT) analysis (CALIPER) against visual CT scoring and pulmonary function tests (PFTs) when predicting mortality in patients with connective tissue disease-related interstitial lung disease (CTD-ILD). To identify outcome differences between distinct CTD-ILD groups derived following automated stratification of CALIPER variables. A total of 203 consecutive patients with assorted CTD-ILDs had CT parenchymal patterns evaluated by CALIPER and visual CT scoring: honeycombing, reticular pattern, ground glass opacities, pulmonary vessel volume, emphysema, and traction bronchiectasis. CT scores were evaluated against pulmonary function tests: forced vital capacity, diffusing capacity for carbon monoxide, carbon monoxide transfer coefficient, and composite physiologic index for mortality analysis. Automated stratification of CALIPER-CT variables was evaluated in place of and alongside forced vital capacity and diffusing capacity for carbon monoxide in the ILD gender, age physiology (ILD-GAP) model using receiver operating characteristic curve analysis. Cox regression analyses identified four independent predictors of mortality: patient age (P < 0.0001), smoking history (P = 0.0003), carbon monoxide transfer coefficient (P = 0.003), and pulmonary vessel volume (P < 0.0001). Automated stratification of CALIPER variables identified three morphologically distinct groups which were stronger predictors of mortality than all CT and functional indices. The Stratified-CT model substituted automated stratified groups for functional indices in the ILD-GAP model and maintained model strength (area under curve (AUC) = 0.74, P < 0.0001), ILD-GAP (AUC = 0.72, P < 0.0001). Combining automated stratified groups with the ILD-GAP model (stratified CT-GAP model) strengthened predictions of 1- and 2-year mortality: ILD-GAP (AUC = 0.87 and 0.86, respectively); stratified CT-GAP (AUC = 0.89 and 0.88, respectively

  9. Thermoluminescent dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Lara C, A.; Rivera M, T.; Osorio V, M.; Hernandez O, O.

    2016-10-01

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  10. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  11. Cerebral candidiasis. Computed tomography appearance

    International Nuclear Information System (INIS)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-01-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.)

  12. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  13. Microfocus computed tomography in medicine

    Science.gov (United States)

    Obodovskiy, A. V.

    2018-02-01

    Recent advances in the field of high-frequency power schemes for X-ray devices allow the creation of high-resolution instruments. At the department of electronic devices and Equipment of the St. Petersburg State Electrotechnical University, a model of a microfocus computer tomograph was developed. Used equipment allows to receive projection data with an increase up to 100 times. A distinctive feature of the device is the possibility of implementing various schemes for obtaining projection data.

  14. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  15. Computed tomography of thymic abnormalities

    International Nuclear Information System (INIS)

    Schnyder, P.; Candardjis, G.

    1987-01-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis. (orig.)

  16. Orbital computed tomography: technical aspects

    International Nuclear Information System (INIS)

    Beck, T.J.; Rosenbaum, A.E.; Miller, N.R.

    1982-01-01

    Computed tomographic scanning has revolutionized the diagnosis and management of orbital disease. The best use of this methodology requires knowledge of the principles and appropriate attention to scanning protocols. Computed tomographic scanning of the orbit is a demanding technique requiring thin sections through planes precisely positioned from the topographical anatomy. Ideally, orbital CT should include both transverse axial and coronal sections: The pathological condition and its plane of growth will influence the selection of the optimal plane or section. Coronal sections may be obtained either directly or indirectly by computer reconstruction from contiguous transverse images. Sagittal or oblique sections or both also are useful and may be obtained directly or indirectly. Difficulty in patient positioning may preclude direct sagittal imaging, however. The use of intravenous contrast enhancement is not necessary as a routine technique unless a mass is identified or suspected. Where surgical resection or biopsy of a space-occupying lesion is contemplated, contrast enhancement can be valuable in assessing relative vascularity and aiding diagnostic specificity. It should be continually emphasized that CT is a powerful technology which, in orbital diagnosis, produces the highest yield when clinician and radiologist collaborate in the radiodiagnostic workup. The clinical information supplied by the referring ophthalmologist is used by the radiologist both in the selection of the appropriate techniques for investigation and in striving to achieve the most specific conclusion

  17. Proton computed tomography images with algebraic reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bruzzi, M. [Physics and Astronomy Department, University of Florence, Florence (Italy); Civinini, C.; Scaringella, M. [INFN - Florence Division, Florence (Italy); Bonanno, D. [INFN - Catania Division, Catania (Italy); Brianzi, M. [INFN - Florence Division, Florence (Italy); Carpinelli, M. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Cirrone, G.A.P.; Cuttone, G. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Presti, D. Lo [INFN - Catania Division, Catania (Italy); Physics and Astronomy Department, University of Catania, Catania (Italy); Maccioni, G. [INFN – Cagliari Division, Cagliari (Italy); Pallotta, S. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Randazzo, N. [INFN - Catania Division, Catania (Italy); Romano, F. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Sipala, V. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Talamonti, C. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Vanzi, E. [Fisica Sanitaria, Azienda Ospedaliero-Universitaria Senese, Siena (Italy)

    2017-02-11

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to ~1% and spatial resolutions <1 mm, achieved within processing times of ~15′ for a 512×512 pixels image prove that this technique will be beneficial if used instead of X-CT in hadron-therapy.

  18. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  19. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  20. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  1. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  2. Computed tomography of the menisci

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.; Rupp, N.; Paar, O.; Rodammer, G.

    1988-01-01

    Thirty patients were examined with CT of the menisci. All findings were confirmed by arthroscopy. One false positive diagnosis of a torn meniscus was made, caused by partial volume effect. In seven patients with irregular degenerative changes of the menisci, the abnormality could be clearly demonstrated. One meniscus ganglion was shown. Seven meniscus lesions, which were not shown by arthrography or arthroscopy, were clearly demonstrated by CT. The computer tomographic demonstration of menisci can replace knee arthrography as the examination of choice and should be performed before carrying out arthroscopy. (orig.) [de

  3. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  4. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Golimbu, C.; Bonamo, J.

    1984-01-01

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  5. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... applications. This thesis takes a systematic approach toward establishing quantitative understanding of conditions for sparse reconstruction to work well in CT. A general framework for analyzing sparse reconstruction methods in CT is introduced and two sets of computational tools are proposed: 1...... contributions to a general set of computational characterization tools. Thus, the thesis contributions help advance sparse reconstruction methods toward routine use in...

  6. Computed tomography of pelvic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kimoto, Makoto; Hashimoto, Keiji; Hiraki, Yoshio

    1984-12-01

    Plain x-ray and computed tomographic (CT) findings were compared in 7 patients with pelvic fractures (2 males and 5 females) aged between 35 and 50 year. Plain x-rays had a higher sensitivity than CT in detecting fractures of the ischiatic and pubic ramuses, and deviation of bone fragments. CT was superior to plain x-rays near the acetabulum and in detecting deviation of bone fragments. Although there were no differences between the two modalities in detecting fractures of the wing of ilium, CT was more useful than plain x-rays in visualizing deviation of bone fragments. CT clearly visualized not only fractures but also injuries of the soft tissues, such as pelvic viscera and muscles, and the presence of hematoma. CT seems to be a useful method for observing the condition and process of pelvic injuries and for deciding treatment protocols.

  7. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  8. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches.

    Directory of Open Access Journals (Sweden)

    Rania M Nada

    Full Text Available Superimposition of serial Cone Beam Computed Tomography (CBCT scans has become a valuable tool for three dimensional (3D assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16 for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27 for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... fine tune" the CT settings based on the reason for the exam, the body area being examined, ...

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... cause cancer is debatable but because it is possible, every effort is made to limit the amount ... to restrict the area scanned as much as possible and to "fine tune" the CT settings based ...

  11. Influence of computer tomography on radiological diagnostics of malignant tumors

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, P.; Glueck, E.; Siems, H.

    1981-01-01

    A survey is presented of the present status of cancer diagnostics in the following organs and organ systems: neurocranium, visceral cranium and base of skull, larynx and thyroid, thorax, pancreas, retroperitoneum, kidneys and adrenal glands, pelvis, and skeletal system. The rank of computer tomography is compared with those of other examination techniques.

  12. Computed Tomography-Enhanced Anatomy Course Using Enterprise Visualization

    Science.gov (United States)

    May, Hila; Cohen, Haim; Medlej, Bahaa; Kornreich, Liora; Peled, Nathan; Hershkovitz, Israel

    2013-01-01

    Rapid changes in medical knowledge are forcing continuous adaptation of the basic science courses in medical schools. This article discusses a three-year experience developing a new Computed Tomography (CT)-based anatomy curriculum at the Sackler School of Medicine, Tel Aviv University, including describing the motivations and reasoning for the…

  13. A true minimally invasive approach for cochlear implantation: high accuracy in cranial base navigation through flat-panel-based volume computed tomography.

    Science.gov (United States)

    Majdani, Omid; Bartling, Soenke H; Leinung, Martin; Stöver, Timo; Lenarz, Minoo; Dullin, Christian; Lenarz, Thomas

    2008-02-01

    High-precision intraoperative navigation using high-resolution flat-panel volume computed tomography makes feasible the possibility of minimally invasive cochlear implant surgery, including cochleostomy. Conventional cochlear implant surgery is typically performed via mastoidectomy with facial recess to identify and avoid damage to vital anatomic landmarks. To accomplish this procedure via a minimally invasive approach--without performing mastoidectomy--in a precise fashion, image-guided technology is necessary. With such an approach, surgical time and expertise may be reduced, and hearing preservation may be improved. Flat-panel volume computed tomography was used to scan 4 human temporal bones. A drilling channel was planned preoperatively from the mastoid surface to the round window niche, providing a margin of safety to all functional important structures (e.g., facial nerve, chorda tympani, incus). Postoperatively, computed tomographic imaging and conventional surgical exploration of the drilled route to the cochlea were performed. All 4 specimens showed a cochleostomy located at the scala tympani anterior inferior to the round window. The chorda tympani was damaged in 1 specimen--this was preoperatively planned as a narrow facial recess was encountered. Using flat-panel volume computed tomography for image-guided surgical navigation, we were able to perform minimally invasive cochlear implant surgery defined as a narrow, single-channel mastoidotomy with cochleostomy. Although this finding is preliminary, it is technologically achievable.

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... waves that can be directed at the body. Different body parts absorb the x-rays in varying degrees. ... based on the reason for the exam, the body area being examined, and the child's size. Radiologists generally attempt to use the lowest radiation ...

  15. Online monitoring of the two-dimensional temperature field in a boiler furnace based on acoustic computed tomography

    International Nuclear Information System (INIS)

    Zhang, Shiping; Shen, Guoqing; An, Liansuo; Niu, Yuguang

    2015-01-01

    Online monitoring of the temperature field is crucial to optimally adjust combustion within a boiler. In this paper, acoustic computed tomography (CT) technology was used to obtain the temperature profile of a furnace cross-section. The physical principles behind acoustic CT, acoustic signals and time delay estimation were studied. Then, the technique was applied to a domestic 600-MW coal-fired boiler. Acoustic CT technology was used to monitor the temperature field of the cross-section in the boiler furnace, and the temperature profile was reconstructed through ART iteration. The linear sweeping frequency signal was adopted as the sound source signal, whose sweeping frequency ranged from 500 to 3000 Hz with a sweeping cycle of 0.1 s. The generalized cross-correlation techniques with PHAT and ML were used as the time delay estimation method when the boiler was in different states. Its actual operation indicated that the monitored images accurately represented the combustion state of the boiler, and the acoustic CT system was determined to be accurate and reliable. - Highlights: • An online monitoring approach to monitor temperature field in a boiler furnace. • The paper provides acoustic CT technology to obtain the temperature profile of a furnace cross-section. • The temperature profile was reconstructed through ART iteration. • The technique is applied to a domestic 600-MW coal-fired boiler. • The monitored images accurately represent the combustion state of the boiler

  16. Increased incidence of adrenal gland injury in blunt abdominal trauma: a computed tomography-based study from Pakistan

    Directory of Open Access Journals (Sweden)

    Aziz Muhammad Usman

    2014-02-01

    Full Text Available 【Abstract】Objective: To determine the frequency of adrenal injuries in patients presenting with blunt abdominal trauma by computed tomography (CT. Methods: During a 6 month period from January 1, 2011 to June 30, 2011, 82 emergency CT examinations were performed in the setting of major abdominal trauma and retrospectively reviewed for adrenal gland injuries. Results: A total of 7 patients were identified as having adrenal gland injuries (6 males and 1 female. Two patients had isolated adrenal gland injuries. In the other 5 patients with nonisolated injuries, injuries to the liver (1 case, spleen (1 case, retroperitoneum (2 cases and mesentery (4 cases were identified. Overall 24 cases with liver injuries (29 %, 11 cases with splenic injuries (13%, 54 cases with mesenteric injuries (65%, 14 cases (17% with retroperitoneal injuries and 9 cases with renal injuries were identified. Conclusion: Adrenal gland injury is identified in 7 patients (11.7% out of a total of 82 patients who underwent CT after major abdominal trauma. Most of these cases were nonisolated injuries. Our experience indicates that adrenal injury resulting from trauma is more common than suggested by other reports. The rise in incidence of adrenal injuries could be attributed to the mode of injury.

  17. Synchrotron-radiation-based X-ray micro-computed tomography reveals dental bur debris under dental composite restorations.

    Science.gov (United States)

    Hedayat, Assem; Nagy, Nicole; Packota, Garnet; Monteith, Judy; Allen, Darcy; Wysokinski, Tomasz; Zhu, Ning

    2016-05-01

    Dental burs are used extensively in dentistry to mechanically prepare tooth structures for restorations (fillings), yet little has been reported on the bur debris left behind in the teeth, and whether it poses potential health risks to patients. Here it is aimed to image dental bur debris under dental fillings, and allude to the potential health hazards that can be caused by this debris when left in direct contact with the biological surroundings, specifically when the debris is made of a non-biocompatible material. Non-destructive micro-computed tomography using the BioMedical Imaging & Therapy facility 05ID-2 beamline at the Canadian Light Source was pursued at 50 keV and at a pixel size of 4 µm to image dental bur fragments under a composite resin dental filling. The bur's cutting edges that produced the fragment were also chemically analyzed. The technique revealed dental bur fragments of different sizes in different locations on the floor of the prepared surface of the teeth and under the filling, which places them in direct contact with the dentinal tubules and the dentinal fluid circulating within them. Dispersive X-ray spectroscopy elemental analysis of the dental bur edges revealed that the fragments are made of tungsten carbide-cobalt, which is bio-incompatible.

  18. [Fabrication and accuracy research on 3D printing dental model based on cone beam computed tomography digital modeling].

    Science.gov (United States)

    Zhang, Hui-Rong; Yin, Le-Feng; Liu, Yan-Li; Yan, Li-Yi; Wang, Ning; Liu, Gang; An, Xiao-Li; Liu, Bin

    2018-04-01

    The aim of this study is to build a digital dental model with cone beam computed tomography (CBCT), to fabricate a virtual model via 3D printing, and to determine the accuracy of 3D printing dental model by comparing the result with a traditional dental cast. CBCT of orthodontic patients was obtained to build a digital dental model by using Mimics 10.01 and Geomagic studio software. The 3D virtual models were fabricated via fused deposition modeling technique (FDM). The 3D virtual models were compared with the traditional cast models by using a Vernier caliper. The measurements used for comparison included the width of each tooth, the length and width of the maxillary and mandibular arches, and the length of the posterior dental crest. 3D printing models had higher accuracy compared with the traditional cast models. The results of the paired t-test of all data showed that no statistically significant difference was observed between the two groups (P>0.05). Dental digital models built with CBCT realize the digital storage of patients' dental condition. The virtual dental model fabricated via 3D printing avoids traditional impression and simplifies the clinical examination process. The 3D printing dental models produced via FDM show a high degree of accuracy. Thus, these models are appropriate for clinical practice.

  19. The effects of gas diffusion layers structure on water transportation using X-ray computed tomography based Lattice Boltzmann method

    Science.gov (United States)

    Jinuntuya, Fontip; Whiteley, Michael; Chen, Rui; Fly, Ashley

    2018-02-01

    The Gas Diffusion Layer (GDL) of a Polymer Electrolyte Membrane Fuel Cell (PEMFC) plays a crucial role in overall cell performance. It is responsible for the dissemination of reactant gasses from the gas supply channels to the reactant sites at the Catalyst Layer (CL), and the adequate removal of product water from reactant sites back to the gas channels. Existing research into water transport in GDLs has been simplified to 2D estimations of GDL structures or use virtual stochastic models. This work uses X-ray computed tomography (XCT) to reconstruct three types of GDL in a model. These models are then analysed via Lattice Boltzmann methods to understand the water transport behaviours under differing contact angles and pressure differences. In this study, the three GDL samples were tested over the contact angles of 60°, 80°, 90°, 100°, 120° and 140° under applied pressure differences of 5 kPa, 10 kPa and 15 kPa. By varying the contact angle and pressure difference, it was found that the transition between stable displacement and capillary fingering is not a gradual process. Hydrophilic contact angles in the region of 60°<θ < 90° showed stable displacement properties, whereas contact angles in the region of 100°<θ < 140° displayed capillary fingering characteristics.

  20. Revising the lower statistical limit of x-ray grating-based phase-contrast computed tomography.

    Science.gov (United States)

    Marschner, Mathias; Birnbacher, Lorenz; Willner, Marian; Chabior, Michael; Herzen, Julia; Noël, Peter B; Pfeiffer, Franz

    2017-01-01

    Phase-contrast x-ray computed tomography (PCCT) is currently investigated as an interesting extension of conventional CT, providing high soft-tissue contrast even if examining weakly absorbing specimen. Until now, the potential for dose reduction was thought to be limited compared to attenuation CT, since meaningful phase retrieval fails for scans with very low photon counts when using the conventional phase retrieval method via phase stepping. In this work, we examine the statistical behaviour of the reverse projection method, an alternative phase retrieval approach and compare the results to the conventional phase retrieval technique. We investigate the noise levels in the projections as well as the image quality and quantitative accuracy of the reconstructed tomographic volumes. The results of our study show that this method performs better in a low-dose scenario than the conventional phase retrieval approach, resulting in lower noise levels, enhanced image quality and more accurate quantitative values. Overall, we demonstrate that the lower statistical limit of the phase stepping procedure as proposed by recent literature does not apply to this alternative phase retrieval technique. However, further development is necessary to overcome experimental challenges posed by this method which would enable mainstream or even clinical application of PCCT.

  1. Spiral Computed Tomography Based Maxillary Sinus Imaging in Relation to Tooth Loss, Implant Placement and Potential Grafting Procedure

    Directory of Open Access Journals (Sweden)

    Reinhilde Jacobs

    2010-01-01

    Full Text Available Objectives: The purpose of the present study was to explore the maxillary sinus anatomy, its variations and volume in patients with a need for maxillary implant placement.Materials and Methods: Maxillary sinus data of 101 consecutive patients who underwent spiral computed tomography (CT scans for preoperative implant planning in the maxilla at the Department of Periodontology, University Hospital, Catholic University of Leuven, Leuven, Belgium were retrospectively evaluated. The alveolar bone height was measured on serial cross-sectional images between alveolar crest and sinus floor, parallel to the tooth axis. In order to describe the size of the maxillary sinus anteroposterior (AP and mediolateral (ML diameters of the sinus were measured.Results: The results indicated that the alveolar bone height was significantly higher in the premolar regions in comparison to the molar region (n = 46, P 4 mm mucosal thickening mostly at the level of the sinus floor. The present sample did not allow revealing any significant difference (P > 0.05 in maxillary sinus dimensions for partially dentate and edentulous subjects.Conclusions: Cross-sectional imaging can be used in order to obtain more accurate information on the morphology, variation, and the amount of maxillary bone adjacent to the maxillary sinus.

  2. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  3. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  4. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  5. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  6. Soil structure changes evaluated with computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz Fernando

    2010-01-01

    The objective of this work was to evaluate in millimetric scale changes in soil bulk density and porosity, using the gamma-ray computed tomography in soil samples with disturbed structure due to wetting and drying (W-D) cycles. Soil samples with 98.1 cm 3 were sieved using a 2 mm mesh and homogeneously packed in PVC cylinders. Soil samples were submitted to 1, 2, and 3 W-D cycles. Control samples were not submitted to W-D cycles. After repetitions of W-D cycles, soil sample porosity decreased and soil layers became denser. Computed tomography allowed a continuous analysis of soil bulk density and also soil porosity along millimetric (0.08 cm) layers, what cannot be provided by traditional methods used in soil physics. (author)

  7. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Vymazal, J.; Bauer, J.

    1983-01-01

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  8. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  9. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  10. Comparison of Accuracy of Contrast Enhanced Computed Tomography with Accuracy of Non-Contrast Magnetic Resonance Imaging in Evaluation of Local Extension of Base of Tongue Malignancies

    Directory of Open Access Journals (Sweden)

    Ketan Rathod

    2018-01-01

    Full Text Available Diagnosis of base of tongue malignancy can be obtained through clinical examination and biopsy. Magnetic Resonance Imaging (MRI and Computed Tomography (CT are used to detect its local extension, nodal spread and distant metastases. The main aim of study was to compare the accuracy of MRI and contrast enhanced CT in determining the local extent of base of tongue malignancy. Twenty five patients, biopsy proven cases of squamous cell carcinoma of base of tongue were taken. 1.5 Tesla Magnetic Resonance Unit with T2 weighted axial, coronal image; T1 weighted axial, coronal image; and STIR (Short tau inversion recovery axial and coronal images were used. 16 slice Computed Tomography unit with non-contrast and contrast enhanced images were used. Accuracy of CT to detect midline crossing: 50%; accuracy of MRI to detect midline crossing: 100%; accuracy of CT to detect anterior extension: 92%; accuracy of MRI to detect anterior extension: 100%; accuracy of CT to detect tonsillar fossa invasion: 83%; accuracy of MRI to detect tonsillar fossa invasion: 100%; accuracy of CT to detect oro pharyngeal spread: 83%; accuracy of MRI to detect oro pharyngeal spread: 100%; accuracy of CT to detect bone involvement: 20%; accuracy of MRI to detect bone involvement: 100%. MRI proved to be a better investigation than CT, in terms of evaluation of depth of invasion, presence of bony involvement, extension to opposite side, anterior half of tongue, tonsillar fossa, floor of mouth or oropharynx.

  11. Computed tomography and radioprotection: Knowing and acting

    International Nuclear Information System (INIS)

    Ducou Le Pointe, H.

    2013-01-01

    Exposure of the population to ionizing radiation for medical purposes is increasing throughout the world. In the United States of America, this exposure (3 mSv) has reached, even exceeded, exposure from natural sources. In France, the report of the French Institute for Radiological Protection and Nuclear Safety (IRSN) on exposure of the French population to ionizing radiation in 2007, based on the 74.6 million medical diagnostic procedures, estimates the mean individual effective dose to be 1.3 mSv. This value is much lower than the value in the United States but has progressed in 5 years by 62.5%. Computed tomography accounts for 10.1% of the procedures and 58% of the collective effective dose. This is why computed tomography is receiving very special attention from all those involved in radioprotection. It must be remembered, nevertheless, that we are well within the low dose range (effective dose less than 100 mSv), and indeed, in the large majority of CT examinations exposure values are lower than 15 mSv. The biological effects of low doses are still a matter of debate. First of all, it has not been possible to demonstrate the risk of cancer due to this level of exposure, neither on the survivors of the atomic bombs in Japan nor on workers in the nuclear industry in the United Kingdom. The year 2012 marked a change; for the first time, epidemiology took over from statistical studies. Despite the low risk demonstrated, reserves concerning methodology, and waiting for further European epidemiological studies underway, we must continue to act to encourage radiological protection. Before considering the action to take and without under-estimating the risks, it is important to remember that a computed tomography investigation is conducted in patients, and not in individuals in good health. Acting to provide patients with protection from radiation means involving all those concerned with justifying it, with substituting it, and with optimising it. For some years

  12. Xenon as an adjunct in computed tomography

    International Nuclear Information System (INIS)

    Kendall, B.E.; Radue, E.W.; Zilkha, E.; Loh, L.

    1979-01-01

    Nonradioactive xenon was used for enhancement in computed tomography in a series of 18 patients requiring general anesthesia. The method and results are described. The properties of xenon are radically different from those of intravenous iodides, and the enhancement patterns demonstrate different aspects of both normal and abnormal tissues. In our limited experience, it has been of value in those isodense and low attenuation lesions that have not enhanced after intravenous Conray. (orig.) 891 MG/orig. 892 MB [de

  13. Computed tomography of the eye and orbit

    International Nuclear Information System (INIS)

    Hammerschlag, S.B.; Hesselink, J.R.; Weber, A.L.

    1982-01-01

    This book is the product of the evolution of computed tomography (CT) into subspecialization and the need for one source of information for the busy radiologist. The authors have succeeded in providing a readable overview of orbital CT as well as a reference book. The book is divided into seven major catagories of pathology (Neurofibromatosis, Primary Orbital Neoplasms, Secondary and Metastic Tumors of the Orbit, Vascular Disorders, Inflammatory Disease, Occular Lesions, and Trauma) after separate discussions of anatomy and technique

  14. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias; Furtwaengler, Alex

    2003-01-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST ( 5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  15. Computed tomography in opportunistic lung infections

    International Nuclear Information System (INIS)

    Hartelius, H.

    1988-01-01

    Chest radiography in two teenage boys, one with Wiscott-Aldrich's syndrome and one with acute lymphatic leucemia in remission showed increased interstitial pattern. In both computed tomography (CT) of the lungs showed heavy interstitial pneumonia, rather different in appearance but in both cases equal to the CT findings in opportunistic lung infections known from immunoincompetent patients with for instance pneumocystis carinii and/or cytomegalo virus infections. In both patients the CT findings led to lung biopsy establishing the etiologic agent. (orig.)

  16. Cranial computed tomography of the neurofibromatosis

    International Nuclear Information System (INIS)

    Fukuda, Teruo; Inoue, Yuichi; Shibakiri, Ippei

    1981-01-01

    The computed tomography (CT) was performed in 10 cases of neurofibromatosis. The CT scan showed the abnormal findings in 8 cases out of 10. Skull lesions were noted in 3 cases and intracranial tumors were found in 5 among which multiple neoplasms were seen in 3. Although reported cases were not large enough in number, the incidence and variety of the tumors were similar to others reported before CT era. (author)

  17. Computed tomography manifestations of peritoneal diseases

    International Nuclear Information System (INIS)

    Gordon, K.; Lee, W.K.; Hennessy, O.

    2005-01-01

    The peritoneal cavity is a potential space that is divided by the peritoneal reflections into various complex subspaces. It can be involved in many disease processes including developmental, inflammatory, neoplastic and traumatic conditions. Computed tomography is highly sensitive and consistent in detecting peritoneal pathology. This pictorial essay aims to emphasize and illustrate the CT features of the spectrum of peritoneal diseases. Copyright (2005) Blackwell Science Pty Ltd

  18. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  19. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    International Nuclear Information System (INIS)

    Smith, S.L.; Hampson, F.; Duxbury, M.; Rae, D.M.; Sinclair, M.T.

    2008-01-01

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications

  20. Fatty kidney diagnosed by mortem computed tomography

    DEFF Research Database (Denmark)

    Leth, P. M.

    2016-01-01

    Subnuclear vacuolization of the renal tubular epithelium is indicative of diabetic and alcoholic ketoacidosis and has also been proposed as a postmortem marker for hypothermia. We present for the first time a fatal case of ketoacidosis in combination with exposure where a suspicion of these diagn...... of these diagnoses was raised by a marked radiolucency of the kidneys at post-mortem computed tomography (PMCT). © 2015 Elsevier Ltd....

  1. Computed tomography of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Choi, Soomi; Nakamura, Hitonobu; Tanaka, Ken; Hori, Shinichi; Tokunaga, Kou

    1983-01-01

    Based on a series of CT of the liver in 125 patients with hepatoma and 45 patients with metastatic hepatic tumors, the mode of dilatation of the intrahepatic bile duct was examined. In patients with hepatoma, partia dilatations of intrahepatic bile duct were more commonly seen than general dilatations. On the other hand, there was no case of partial dilatation of the intrahepatic bile duct in patients with metastatic hepatic tumors. It could be concluded that partial dilatation of the intrahepatic bile duct is an useful CT finding to make a diagnosis of hepatoma, particularly to differentiate hepatoma from metastatic hepatic tumor. (author)

  2. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  3. Computed tomography in intracranial malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, S; Odake, G; Fujimoto, M; Yamaki, T; Mizukawa, N [Kyoto Prefectural Univ. of Medicine (Japan)

    1978-09-01

    Malignant lymphoma of the central nervous system has been found more and more often in recent years, partly because of the increased use of radiation and such drugs as steroids and antibiotics. However, the definite diagnosis of this disease is difficult until histological verification has been done by operation or autopsy. Since the revolutionary development of computed tomography, however, several reports have been presented, on the computed tomography of malignant lymphoma of the thorax and abdomen. Nevertheless, only a few cases of intracranial malignant lymphoma have been reported. The purpose of this paper, using four patients, is to emphasize the value of computed tomography in the diagnosis of intracranial malignant lymphoma. The characteristic CT findings of intracranial malignant lymphoma may be summarized follows: (1) the tumors are demonstrated to be well-defined, nodular-shaped, and homogenous isodensity - or slightly high-density - lesions in plain scans, and the tumors homogenously increase in density upon contrast enhancement; (2) the disease always has multifocal intracranial lesions, which are shown simultaneously or one after another, and (3) perifocal edema is prominent around the tumors in the cerebral hemisphere.

  4. Kimura's disease: imaging patterns on computed tomography

    International Nuclear Information System (INIS)

    Gopinathan, Anil; Tan, T.Y.

    2009-01-01

    Aim: To define the role of computed tomography (CT) in identifying and classifying the imaging patterns of diagnostic value in Kimura's disease of the head and neck. Methods: A retrospective study was undertaken comprising 13 patients with histopathological evidence of Kimura's disease. The patients' clinical and pathological records were reviewed against a detailed analysis of their CT images performed from the base of the skull to the arch of the aorta. Results: Both well-defined, nodular masses, as well as ill-defined plaque-like infiltrative masses were seen in the subcutaneous tissue of the head and neck region. All patients had lesions adjacent to the major salivary glands. The parotid gland was affected in 10 of the 13 cases and the submandibular gland was affected in the rest. Contrast enhancement was variable. More than half of the cases had associated lymphadenopathy. Some of them showed atrophy of the skin and subcutaneous fat overlying the subcutaneous masses. Blood eosinophilia was a consistent feature in all the cases. Conclusion: The patterns of distribution, morphology, and enhancement of the lesions in Kimura's disease that can be demonstrated at CT, enables a confident, non-invasive diagnosis of this condition, in an appropriate clinical context.

  5. Virtual computed tomography cystoscopy in bladder pathologies

    International Nuclear Information System (INIS)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban

    2006-01-01

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  6. High resolution computed tomography of positron emitters

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Cahoon, J.L.; Huesman, R.H.; Jackson, H.G.

    1976-10-01

    High resolution computed transaxial radionuclide tomography has been performed on phantoms containing positron-emitting isotopes. The imaging system consisted of two opposing groups of eight NaI(Tl) crystals 8 mm x 30 mm x 50 mm deep and the phantoms were rotated to measure coincident events along 8960 projection integrals as they would be measured by a 280-crystal ring system now under construction. The spatial resolution in the reconstructed images is 7.5 mm FWHM at the center of the ring and approximately 11 mm FWHM at a radius of 10 cm. We present measurements of imaging and background rates under various operating conditions. Based on these measurements, the full 280-crystal system will image 10,000 events per sec with 400 μCi in a section 1 cm thick and 20 cm in diameter. We show that 1.5 million events are sufficient to reliably image 3.5-mm hot spots with 14-mm center-to-center spacing and isolated 9-mm diameter cold spots in phantoms 15 to 20 cm in diameter

  7. Gradient computation for VTI acoustic wavefield tomography

    KAUST Repository

    Li, Vladimir

    2016-09-06

    Wavefield tomography can handle complex subsurface geology better than ray-based techniques and, ultimately, provide a higher resolution. Here, we implement forward and adjoint wavefield extrapolation for VTI (transversely isotropic with a vertical symmetry axis) media using a pseudospectral operator that employes a separable approximation of the P-wave dispersion relation. This operator is employed to derive the gradients of the differential semblance optimization (DSO) and modified stack-power objective functions. We also obtain the gradient expressions for the data-domain objective function, which can incorporate borehole information necessary for stable VTI velocity analysis. These gradients are compared to the ones obtained with a space-time finite-difference (FD) scheme for a system of coupled wave equations. Whereas the kernels computed with the two wave-equation operators are similar, the pseudospectral method is not hampered by the imprint of the shear-wave artifact. Numerical examples also show that the modified stack-power objective function produces cleaner gradients than the more conventional DSO operator.

  8. Dynamic X-ray computed tomography

    International Nuclear Information System (INIS)

    Grangeat, P.

    2003-01-01

    Paper Dynamic computed tomography (CT) imaging aims at reconstructing image sequences where the dynamic nature of the living human body is of primary interest. Main concerned applications are image-guided interventional procedures, functional studies and cardiac imaging. The introduction of ultra-fast rotating gantries along with multi-row detectors and in near future area detectors allows a huge progress toward the imaging of moving organs with low-contrast resolution. This paper gives an overview of the different concepts used in dynamic CT. A new reconstruction algorithm based on a voxel-specific dynamic evolution compensation is also presented. It provides four-dimensional image sequences with accurate spatio-temporal information, where each frame is reconstructed using a long-scan acquisition mode on several half-turns. In the same time, this technique permits to reduce the dose delivered per rotation while keeping the same signal to noise ratio for every frame using an adaptive motion-compensated temporal averaging. Results are illustrated on simulated data. (authors)

  9. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  10. Basic principles of cone beam computed tomography.

    Science.gov (United States)

    Abramovitch, Kenneth; Rice, Dwight D

    2014-07-01

    At the end of the millennium, cone-beam computed tomography (CBCT) heralded a new dental technology for the next century. Owing to the dramatic and positive impact of CBCT on implant dentistry and orthognathic/orthodontic patient care, additional applications for this technology soon evolved. New software programs were developed to improve the applicability of, and access to, CBCT for dental patients. Improved, rapid, and cost-effective computer technology, combined with the ability of software engineers to develop multiple dental imaging applications for CBCT with broad diagnostic capability, have played a large part in the rapid incorporation of CBCT technology into dentistry. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  12. Computed tomography of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Hoe, J.W.M.

    1989-01-01

    Axial CT findings of 56 patients with biopsy-proven nasopharyngeal carcinoma (NPC) were reviewed retrospectively to evaluate the region of origin of the tumor and the sites of spread of the disease. In all patients asymmetry of the mucosal airway contour with blunting of the fossa of Rosenmueller was seen, usually associated with infiltration of the levator palatini muscle. The earliest lesion of NPC arose in this region, and in 64% of cases the tumor had infiltrated into the adjacent parapharyngeal space with loss of its normal fat density. Superior intracranial extension was the most common site of deep infiltration from here (45% of patients) with opacification of the sphenoid sinus in 41% and bony destruction of the skull base in 29%. Invasion into the retropharyngeal space (38%) and carotid space (23%) were the next most common sites of infiltration. Invasion into the prevertebral space was seen in 14%. Anterior spread to the masticator space including the infratemporal fossa was an uncommon finding (14%). T-staging of these patients by CT was also done using both the AJC and Ho classification systems. Lymph node metastases were found in many patients (38%), most commonly in the retropharyngeal nodes, internal jugular nodes including jugular-digastricus nodes and the spinal assessory nodes, respectively. CT remains the most reliable technique for staging and assessing the extent of NPC, both prior to and after radiotherapy, and should be used not only for T-staging of the disease, but also for N-staging. It is recommended that axial scans should be routinely extended down the neck to the clavicles in all patients with NPC. (orig.)

  13. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    Science.gov (United States)

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  14. Computed tomography of the breast cancer

    International Nuclear Information System (INIS)

    Chung, Soo Young; Lee, Yul; Bae, Sang Hoon; Yoon, Jong Sup; Lee, Ki Chu

    1985-01-01

    The indication of computed tomography for the breast lesion are 1) Unusually extensive or small breast caused technical difficulties in performing mammograms. 2) Questionable mammographic findings, especially in dense proliferative breast parenchyme. 3) Microcancer. 4) Suspicious regional lymph node enlargement or invasive of the chest wall by breast cancer. The diagnosis of breast CT in breast cancer is based on pathologic anatomic changes and characteristic increase of mean CT No. of lesion following contrast enhancement. Authors analysed CT of the 34 patients who were clinically suspected breast cancer, and compared with mammography. The results are as follows: 1. Pathological diagnosis of 34 cases were 27 cases of breast cancer, 4 cases of fibrocystic disease, 2 cases of fibroadenoma, and 1 case of intraductal papilloma. The diagnostic accuracy of CT in 27 breast cancer was 93% (25 cases) and mammography 71% (19 case). 2. Correct diagnosis of CT in 7 benign breast disease is in 5 cases and mammography in 5 cases. 3. The most important finding of CT in breast cancer is characteristic increase of CT No. of lesion following contrast enhancement (200 ml, 65%): over average 50 HU in 19 cases of 27 breast cancers, 30-50 HU in a 6 cases, 20-30 HU in 2 cases with tumor necrosis. 4. Computed with mammography, other more valuable CT findings of breast cancer are axillary lymph node enlargement and adjacentic pectoral muscle invasion. 5. In conclusion, breast CT is considered as valuable diagnostic tool in evaluation of breast cancer, but not of benign breast disease

  15. Computed tomography of the breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Lee, Yul; Bae, Sang Hoon; Yoon, Jong Sup; Lee, Ki Chu [Hallym University Medical Center, Seoul (Korea, Republic of)

    1985-12-15

    The indication of computed tomography for the breast lesion are 1) Unusually extensive or small breast caused technical difficulties in performing mammograms. 2) Questionable mammographic findings, especially in dense proliferative breast parenchyme. 3) Microcancer. 4) Suspicious regional lymph node enlargement or invasive of the chest wall by breast cancer. The diagnosis of breast CT in breast cancer is based on pathologic anatomic changes and characteristic increase of mean CT No. of lesion following contrast enhancement. Authors analysed CT of the 34 patients who were clinically suspected breast cancer, and compared with mammography. The results are as follows: 1. Pathological diagnosis of 34 cases were 27 cases of breast cancer, 4 cases of fibrocystic disease, 2 cases of fibroadenoma, and 1 case of intraductal papilloma. The diagnostic accuracy of CT in 27 breast cancer was 93% (25 cases) and mammography 71% (19 case). 2. Correct diagnosis of CT in 7 benign breast disease is in 5 cases and mammography in 5 cases. 3. The most important finding of CT in breast cancer is characteristic increase of CT No. of lesion following contrast enhancement (200 ml, 65%): over average 50 HU in 19 cases of 27 breast cancers, 30-50 HU in a 6 cases, 20-30 HU in 2 cases with tumor necrosis. 4. Computed with mammography, other more valuable CT findings of breast cancer are axillary lymph node enlargement and adjacentic pectoral muscle invasion. 5. In conclusion, breast CT is considered as valuable diagnostic tool in evaluation of breast cancer, but not of benign breast disease.

  16. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  17. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  18. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  19. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. Copyright © 2010. Published by Elsevier Inc.

  20. Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancer

    International Nuclear Information System (INIS)

    Yeo, Seung Gu; Kim, Eun Seog

    2013-01-01

    This study aimed to investigate efficient approaches for determining internal target volume (ITV) from four-dimensional computed tomography (4D CT) images used in stereotactic body radiotherapy (SBRT) for patients with early-stage non-small cell lung cancer (NSCLC). 4D CT images were analyzed for 15 patients who received SBRT for stage I NSCLC. Three different ITVs were determined as follows: combining clinical target volume (CTV) from all 10 respiratory phases (ITV 10Phases ); combining CTV from four respiratory phases, including two extreme phases (0% and 50%) plus two intermediate phases (20% and 70%) (ITV 4Phases ); and combining CTV from two extreme phases (ITV 2Phases ). The matching index (MI) of ITV 4Phases and ITV 2Phases was defined as the ratio of ITV 4Phases and ITV 2Phases , respectively, to the ITV 10Phases . The tumor motion index (TMI) was defined as the ratio of ITV 10Phases to CTV mean , which was the mean of 10 CTVs delineated on 10 respiratory phases. The ITVs were significantly different in the order of ITV 10Phases , ITV 4Phases , and ITV 2Phases (all p 4Phases was significantly higher than that of ITV 2Phases (p 4Phases was inversely related to TMI (r = -0.569, p = 0.034). In a subgroup with low TMI (n = 7), ITV 4Phases was not statistically different from ITV 10Phases (p = 0.192) and its MI was significantly higher than that of ITV 2Phases (p = 0.016). The ITV 4Phases may be an efficient approach alternative to optimal ITV 10Phases in SBRT for early-stage NSCLC with less tumor motion.

  1. Morphological characteristics of the posterior malleolar fragment according to ankle fracture patterns: a computed tomography-based study.

    Science.gov (United States)

    Yi, Young; Chun, Dong-Il; Won, Sung Hun; Park, Suyeon; Lee, Sanghyeon; Cho, Jaeho

    2018-02-13

    The posterior malleolar fragment (PMF) of an ankle fracture can have various shapes depending on the injury mechanism. The purpose of this study was to evaluate the morphological characteristics of the PMF according to the ankle fracture pattern described in the Lauge-Hansen classification by using computed tomography (CT) images. We retrospectively analyzed CT data of 107 patients (107 ankles) who underwent surgery for trimalleolar fracture from January 2012 to December 2014. The patients were divided into two groups: 76 ankles in the supination-external rotation (SER) stage IV group and 31 ankles in the pronation-external rotation (PER) stage IV group. The PMF type of the two groups was assessed using the Haraguchi and Jan Bartonicek classification. The cross angle (α), fragment length ratio (FLR), fragment area ratio (FAR), sagittal angle (θ), and fragment height (FH) were measured to assess the morphological characteristics of the PMF. The PMF in the SER group mainly had a posterolateral shape, whereas that in the PER group mainly had a posteromedial two-part shape or a large posterolateral triangular shape (P = 0.02). The average cross angle was not significantly different between the two groups (SER group = 19.4°, PER group = 17.6°). The mean FLR and FH were significantly larger in the PER group than in the SER group (P = 0.024, P = 0.006). The mean fragment sagittal angle in the PER group was significantly smaller than that in the SER group (P = 0.017). With regard to the articular involvement, volume, and vertical nature, the SER-type fracture tends to have a smaller fragment due to the rotational force, whereas the PER-type fracture tends to have a larger fragment due to the combination of rotational and axial forces.

  2. Incidence of lumbar spondylolysis in the general population in Japan based on multidetector computed tomography scans from two thousand subjects.

    Science.gov (United States)

    Sakai, Toshinori; Sairyo, Koichi; Takao, Shoichiro; Nishitani, Hiromu; Yasui, Natsuo

    2009-10-01

    Epidemiological analysis using CTs. To investigate the true incidence of lumbar spondylolysis in the general population in Japan. Although there have been several reports on the incidence of lumbar spondylolysis, they had some weakness. One of them concerns the subjects investigated, because the incidence of lumbar spondylolysis varies considerably, and some patients are asymptomatic. In addition, most of the past studies used plain radiograph films or skeletal investigation. Therefore, the past reported incidence may not correspond to that of the general population. We reviewed the computed tomography (CT) scans of 2000 subjects (age: 20-92 years) who had undergone abdominal and pelvic CT on a single multidetector CT scanner for reasons unrelated to low back pain. We reviewed them for spondylolysis, spondylolytic spondylolisthesis, and spina bifida occulta (SBO) in the lumbosacral region. The grade (I-IV) of spondylolisthesis was measured using midsagittal reconstructions. Lumbar spondylolysis was found in 117 subjects (5.9%). Their male-female ratio was 2:1. Multiple-level spondylolysis was found in 5 subjects (0.3%). Among these 117 subjects, there were 124 vertebrae with spondylolysis. Of them, 112 (90.3%) corresponded to L5, and 26 (21.0%) had unilateral spondylolysis.SBO was found in 154 subjects. Of them, 25 had spondylolysis (16.2%), whereas, in 1846 subjects without SBO, 92 had spondylolysis (5.0%). The incidence of spondylolysis among the patients with SBO was significantly higher than that in subjects without SBO (Odd ratio was 3.7-fold).Of 124 vertebrae with spondylolysis, 75 (60.5%) showed low-grade (Meyerding grade I or II) spondylolisthesis, and no subject presented high-grade spondylolisthesis. Spondylolisthesis was found in 74.5% of the subjects with bilateral spondylolysis, and in 7.7% of those with unilateral spondylolysis. The incidence of lumbar spondylolysis in the Japanese general population was 5.9% (males: 7.9%, females: 3.9%).

  3. Cone Beam Computed Tomography-based Evaluation of the Anterior Teeth Position Changes obtained by Passive Self-ligating Brackets.

    Science.gov (United States)

    Rhoden, Fernando K; Maltagliati, Liliana Á; de Castro Ferreira Conti, Ana C; Almeida-Pedrin, Renata R; Filho, Leopoldino C; de Almeida Cardoso, Maurício

    2016-08-01

    The objective of this study was to evaluate the anterior teeth position changes obtained by passive self-ligating brackets using cone beam computed tomography (CBCT). Twenty patients with a mean age of 16.5 years, class I malocclusion, constricted maxillary arch, and teeth crowding above 5 mm were enrolled in this study, and treated by passive orthodontic self-ligating brackets. A sequence of stainless steel thermoset wire was implemented with ending wire of 0.019" × 0.025". The CBCT and dental casts were obtained prior to the installation of orthodontic appliances (T1), and 30 days after rectangular steel wire 0.019" × 0.025" installation (T2). The measurements in CBCT were performed with the Anatomage software, and the dental casts were evaluated with a digital caliper rule with an accuracy of 0.01 mm. The CBCT data demonstrated mean buccal inclination of the upper and lower central incisors ranging from 6.55° to 7.24° respectively. The upper and lower lateral incisors ranged from 4.90° to 8.72° respectively. The lower canines showed an average increase of 3.88° in the buccal inclination and 1.96 mm in the transverse intercuspal distance. The upper canines showed a negative inclination with mean average of -0.36°, and an average increase of 0.82 mm in the transverse distance, with negative correlation with the initial crowding. Treatment with passive self-ligating brackets without obtaining spaces increases buccal inclination of the upper and lower incisors with no correlation with the amount of initial teeth crowding. The intercanine distance tends to a small increase showing different inclinations between the arches. When taking into account the self-ligating brackets, the amount of initial dental crowding is not a limitation factor that could increase the buccal inclination of the anterior teeth.

  4. Multi-scale X-ray computed tomography to detect and localize metal-based nanomaterials in lung tissues of in vivo exposed mice.

    Science.gov (United States)

    Chaurand, Perrine; Liu, Wei; Borschneck, Daniel; Levard, Clément; Auffan, Mélanie; Paul, Emmanuel; Collin, Blanche; Kieffer, Isabelle; Lanone, Sophie; Rose, Jérôme; Perrin, Jeanne

    2018-03-13

    In this methodological study, we demonstrated the relevance of 3D imaging performed at various scales for the ex vivo detection and location of cerium oxide nanomaterials (CeO 2 -NMs) in mouse lung. X-ray micro-computed tomography (micro-CT) with a voxel size from 14 µm to 1 µm (micro-CT) was combined with X-ray nano-computed tomography with a voxel size of 63 nm (nano-CT). An optimized protocol was proposed to facilitate the sample preparation, to minimize the experimental artifacts and to optimize the contrast of soft tissues exposed to metal-based nanomaterials (NMs). 3D imaging of the NMs biodistribution in lung tissues was consolidated by combining a vast variety of techniques in a correlative approach: histological observations, 2D chemical mapping and speciation analysis were performed for an unambiguous detection of NMs. This original methodological approach was developed following a worst-case scenario of exposure, i.e. high dose of exposure with administration via intra-tracheal instillation. Results highlighted both (i) the non-uniform distribution of CeO 2 -NMs within the entire lung lobe (using large field-of-view micro-CT) and (ii) the detection of CeO 2 -NMs down to the individual cell scale, e.g. macrophage scale (using nano-CT with a voxel size of 63 nm).

  5. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    Sawicka, B.

    1992-01-01

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  6. Spectrum of single photon emission computed tomography/computed tomography findings in patients with parathyroid adenomas.

    Science.gov (United States)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Harisankar, Chidambaram Natrajan Balasubramanian; Bhattacharya, Anish; Bhadada, Sanjay

    2011-01-01

    Primary hyperparathyroidism results from excessive parathyroid hormone secretion. Approximately 85% of all cases of primary hyperparathyroidism are caused by a single parathyroid adenoma; 10-15% of the cases are caused by parathyroid hyperplasia. Parathyroid carcinoma accounts for approximately 3-4% of cases of primary disease. Technetium-99m-sestamibi (MIBI), the current scintigraphic procedure of choice for preoperative parathyroid localization, can be performed in various ways. The "single-isotope, double-phase technique" is based on the fact that MIBI washes out more rapidly from the thyroid than from abnormal parathyroid tissue. However, not all parathyroid lesions retain MIBI and not all thyroid tissue washes out quickly, and subtraction imaging is helpful. Single photon emission computed tomography (SPECT) provides information for localizing parathyroid lesions, differentiating thyroid from parathyroid lesions, and detecting and localizing ectopic parathyroid lesions. Addition of CT with SPECT improves the sensitivity. This pictorial assay demonstrates various SPECT/CT patterns observed in parathyroid scintigraphy.

  7. Accuracy of Ultrasound-Based (BAT) Prostate-Repositioning: A Three-Dimensional On-Line Fiducial-Based Assessment With Cone-Beam Computed Tomography

    International Nuclear Information System (INIS)

    Boda-Heggemann, Judit; Koehler, Frederick Marc; Kuepper, Beate; Wolff, Dirk; Wertz, Hansjoerg; Mai, Sabine; Hesser, Juergen; Lohr, Frank; Wenz, Frederik

    2008-01-01

    Purpose: To assess the accuracy of ultrasound-based repositioning (BAT) before prostate radiation with fiducial-based three-dimensional matching with cone-beam computed tomography (CBCT). Patients and Methods: Fifty-four positionings in 8 patients with 125 I seeds/intraprostatic calcifications as fiducials were evaluated. Patients were initially positioned according to skin marks and after this according to bony structures based on CBCT. Prostate position correction was then performed with BAT. Residual error after repositioning based on skin marks, bony anatomy, and BAT was estimated by a second CBCT based on user-independent automatic fiducial registration. Results: Overall mean value (MV ± SD) residual error after BAT based on fiducial registration by CBCT was 0.7 ± 1.7 mm in x (group systematic error [M] = 0.5 mm; SD of systematic error [Σ] = 0.8 mm; SD of random error [σ] = 1.4 mm), 0.9 ± 3.3 mm in y (M = 0.5 mm, Σ = 2.2 mm, σ = 2.8 mm), and -1.7 ± 3.4 mm in z (M = -1.7 mm, Σ = 2.3 mm, σ = 3.0 mm) directions, whereas residual error relative to positioning based on skin marks was 2.1 ± 4.6 mm in x (M = 2.6 mm, Σ = 3.3 mm, σ = 3.9 mm), -4.8 ± 8.5 mm in y (M = -4.4 mm, Σ = 3.7 mm, σ = 6.7 mm), and -5.2 ± 3.6 mm in z (M = -4.8 mm, Σ = 1.7 mm, σ = 3.5mm) directions and relative to positioning based on bony anatomy was 0 ± 1.8 mm in x (M = 0.2 mm, Σ = 0.9 mm, σ = 1.1 mm), -3.5 ± 6.8 mm in y (M = -3.0 mm, Σ = 1.8 mm, σ = 3.7 mm), and -1.9 ± 5.2 mm in z (M = -2.0 mm, Σ = 1.3 mm, σ = 4.0 mm) directions. Conclusions: BAT improved the daily repositioning accuracy over skin marks or even bony anatomy. The results obtained with BAT are within the precision of extracranial stereotactic procedures and represent values that can be achieved with several users with different education levels. If sonographic visibility is insufficient, CBCT or kV/MV portal imaging with implanted fiducials are recommended

  8. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  9. Positron computed tomography: current state, clinical results and future trends

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  10. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-01-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  11. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  12. Comparison of algebraic and analytical approaches to the formulation of the statistical model-based reconstruction problem for X-ray computed tomography.

    Science.gov (United States)

    Cierniak, Robert; Lorent, Anna

    2016-09-01

    The main aim of this paper is to investigate properties of our originally formulated statistical model-based iterative approach applied to the image reconstruction from projections problem which are related to its conditioning, and, in this manner, to prove a superiority of this approach over ones recently used by other authors. The reconstruction algorithm based on this conception uses a maximum likelihood estimation with an objective adjusted to the probability distribution of measured signals obtained from an X-ray computed tomography system with parallel beam geometry. The analysis and experimental results presented here show that our analytical approach outperforms the referential algebraic methodology which is explored widely in the literature and exploited in various commercial implementations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Intermuscular pterygoid-temporal abscess following inferior alveolar nerve block anesthesia-A computer tomography based navigated surgical intervention: Case report and review.

    Science.gov (United States)

    Wallner, Jürgen; Reinbacher, Knut Ernst; Pau, Mauro; Feichtinger, Matthias

    2014-01-01

    Inferior alveolar nerve block (IANB) anesthesia is a common local anesthetic procedure. Although IANB anesthesia is known for its safety, complications can still occur. Today immediately or delayed occurring disorders following IANB anesthesia and their treatment are well-recognized. We present a case of a patient who developed a symptomatic abscess in the pterygoid region as a result of several inferior alveolar nerve injections. Clinical symptoms included diffuse pain, reduced mouth opening and jaw's hypomobility and were persistent under a first step conservative treatment. Since image-based navigated interventions have gained in importance and are used for various procedures a navigated surgical intervention was initiated as a second step therapy. Thus precise, atraumatic surgical intervention was performed by an optical tracking system in a difficult anatomical region. A symptomatic abscess was treated by a computed tomography-based navigated surgical intervention at our department. Advantages and disadvantages of this treatment strategy are evaluated.

  14. Intermuscular pterygoid-temporal abscess following inferior alveolar nerve block anesthesia–A computer tomography based navigated surgical intervention: Case report and review

    Science.gov (United States)

    Wallner, Jürgen; Reinbacher, Knut Ernst; Pau, Mauro; Feichtinger, Matthias

    2014-01-01

    Inferior alveolar nerve block (IANB) anesthesia is a common local anesthetic procedure. Although IANB anesthesia is known for its safety, complications can still occur. Today immediately or delayed occurring disorders following IANB anesthesia and their treatment are well-recognized. We present a case of a patient who developed a symptomatic abscess in the pterygoid region as a result of several inferior alveolar nerve injections. Clinical symptoms included diffuse pain, reduced mouth opening and jaw's hypomobility and were persistent under a first step conservative treatment. Since image-based navigated interventions have gained in importance and are used for various procedures a navigated surgical intervention was initiated as a second step therapy. Thus precise, atraumatic surgical intervention was performed by an optical tracking system in a difficult anatomical region. A symptomatic abscess was treated by a computed tomography-based navigated surgical intervention at our department. Advantages and disadvantages of this treatment strategy are evaluated. PMID:24987612

  15. Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

    Science.gov (United States)

    Czabaj, M. W.; Riccio, M. L.; Whitacre, W. W.

    2014-01-01

    A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

  16. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    Science.gov (United States)

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  17. Cross-sectional anatomy for computed tomography

    International Nuclear Information System (INIS)

    Farkas, M.L.

    1988-01-01

    This self-study guide recognizes that evaluation and interpretation of CT-images demands a firm understanding of both cross-sectional anatomy and the principles of computed tomography. The objectives of this book are: to discuss the basic principles of CT, to stress the importance of cross-sectional anatomy to CT through study of selected cardinal transverse sections of head, neck, and trunk, to explain orientation and interpretation of CT-images with the aid of corresponding cross-sectional preparations

  18. Computed tomography scans of metastatic hepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Fukuda, Haruyuki; Nemoto, Yutaka [Osaka City Univ. (Japan). Faculty of Medicine

    1984-01-01

    Computed tomography scans of 114 metastatic hepatic tumors were reviewed. Central low density was found in 82 cases (71.9%) and seems to be characteristic to metastatic hepatic tumors. Dynamic CT was performed on 34 cases, and 21 (61.8%) of these had ring enhancement at the arterial phase. Most of metastatic hepatic tumors could be differentiated from hepatocellular carcinoma. However, metastatic hepatic tumors from renal cell carcinoma, renal rhabdomyosarcoma, malignant melanoma and leiomyosarcoma could not be differentiated from hepatocellular carcinoma, even with use of dynamic study.

  19. Computed tomography appearances of sclerosing encapsulating peritonitis

    International Nuclear Information System (INIS)

    George, C.; Al-Zwae, K.; Nair, S.; Cast, J.E.I.

    2007-01-01

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP

  20. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3